Sample records for cup deep drawing

  1. Influence of asymmetrical drawing radius deviation in micro deep drawing

    NASA Astrophysics Data System (ADS)

    Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.

    2017-09-01

    Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.

  2. Deep drawing of 304 L Steel Sheet using Vegetable oils as Forming Lubricants

    NASA Astrophysics Data System (ADS)

    Shashidhara, Y. M.; Jayaram, S. R.

    2012-12-01

    The study involves the evaluation of deep drawing process using two non edible oils, Pongam (Pongammia pinnata) and Jatropha (Jatropha carcass) as metal forming lubricants. Experiments are conducted on 304L steel sheets under the raw and modified oils with suitable punch and die on a hydraulic press of 200 ton capacity. The punch load, draw-in-length and wall thickness distribution for deep drawn cups are observed. The drawn cups are scanned using laser scanning technique and 3D models are generated using modeling package. The wall thickness profiles of cups at different sections (or height) are measured using CAD package. Among the two raw oils, the drawn cups under Jatropha oil, have uniform wall thickness profile compared to Pongam oil. Uneven flow of material and cup rupturing is observed under methyl esters of Pongam and Jatropha oil lubricated conditions. However, the results are observed under epoxidised Jatropha oil with uniform metal flow and wall thicknesses compared to mineral and other versions of vegetable oils.

  3. A Fundamental Study of Stretch-Drawing Process of Sheet Metals : Single and Double Operations

    NASA Astrophysics Data System (ADS)

    Gotoh, Manabu; Kim, Young-soo; Yamashita, Minoru

    1998-05-01

    Fundamental and informative data of axisymmetric stretch-drawing of several sheet metals with thichness of 0.7 1.0 mm are presented especially for single and double operations. Very small radius is applied to the die-profile (or -shoulder) in all operations to induce wall-thinning by the effect of bending-under-tension, from which the name `stretch-drawing' comes. It is clearly demonstrated that deeper cups could be formed by the single and double stretch-drawings from smaller cirlcular blanks due to such wall-thinning action than in the usual deep-drawing of larger blanks. From this fact, it is emphasized that the deep-drawability of a sheet metal is not evaluated simply by the conventional LDR (=limiting drawing ratio), but the depth of the drawn cup should also be taken into account. Many experimental data about various metals and thicknesses given in this paper offer a valueable information on this process for more general use which recommends to replace the conventional deep-drawing process by the stretch-drawing process both for single and double operations. In the single stretch-drawing, it is also confirmed that a deeper cup can be produced by raising the blank-holding force at later stage of operation. Fracturing is found to occur at the middle section of the wall part or at the die-profile other than at the punch profile common in the usual deep-drawing process. Numerical simulation of the single stretch-drawing process is also performed by use of DYNA-3D code to confirm that a satisfactory prediction especially in the depth of the drawn-cup can be done at least in a practical sense, although this kind of numerical analysis is very difficult because of the severity or localization of deformation around the die profile. The drawn cup of SUS304 among others fractures in a couple of weeks after the operation due to the residual circumferential tensile stress, whereas that of SUS304L does not. In the double stretch-drawing, it is confirmed that very deeper cups can be produced when compared to the usual re-drawing process, which assures typically the usefulness of this operation as a practical process. Fracture often takes place circumferentially or, very peculiarly, even in a spiral mode for SUS304 at the middle of the wall part of the cup.

  4. Studies in Cup Drawing Behavior of Polymer Laminated Sheet Metal

    NASA Astrophysics Data System (ADS)

    Elnagmi, M.; Jain, M.; Bruhis, M.; Nielsen, K.

    2011-08-01

    Axisymmetric deep drawing behavior of a polymer laminated sheet metal (PLSM) is investigated using an axisymmetric cup drawing test. PLSMs are of interest as a replacement for painted finishes for automotive applications as they have the potential to achieve good quality long lasting and aesthetically appealing surfaces on stamped parts. However, there is limited understanding of PLSMs in automotive deep drawing situations to produce complex 3-D parts. The tests are carried out using well-controlled, laboratory-based, dual-action, servo-hydraulic forming presses under blank-holder force and punch displacement control conditions. An optical strain mapping system is used to measure the surface strains (and to construct 3D strain maps) from the film side of the deformed samples for a range of forming conditions. Deep drawing characteristics such as punch load versus punch displacement traces, strain distribution along the cup profile, flange wrinkling and fracture characteristics are experimentally assessed for stainless steel-plastic film laminated sheet materials. Also the effect of lamination pressure on wrinkling and delamination is investigated for a decorative pressure sensitive adhesive film affixed to the stainless steel sheet.

  5. Deep drawability of Ti/resin/Ti laminated sheet

    NASA Astrophysics Data System (ADS)

    Hardada, Yasunroi; Hattori, Shuji

    2017-10-01

    Aiming to enhance functionality of titanium cup, the formability of titanium/resin/titanium laminated sheet by deep drawing was investigated. Although pure titanium has excellent corrosion resistance, the density of titanium is higher than that of light metals, such as aluminum and magnesium. Part of the titanium cup made of resin allows for weight reduction of the cup. Furthermore, the clad cup is more likely to have heat retention and protection against vibration characteristics. In the experiment, the materials were pure titanium and polycarbonate. The initial thickness of the sheet was 0.2 to 0.5 mm in thickness. A total plate thickness of the blank was 1.0 to 1.5 mm in thickness. The blank diameter is 70 mm. The laminated sheet was constituted by interposing resin between two titanium sheets. Each sheet in stacked condition was not joined each other. In the deep drawing process, the laminated sheet was employed and a flat sheet blank was formed into a circle by a punch. For the prevention of seizure in contact area between a drawing tool and titanium, titanium blank was treated by oxide coating. By this method, the fresh and clean titanium is not in direct contact with the die during the forming due to the existence of the oxide layer. The deep drawing was carried out to investigate the formability. The laminated sheet was successfully drawn without the cracks. The section of the drawn cup was observed to examine a formability of the resin sheet. The reduction rate of the thickness was less than 10%. It was found that the titanium/resin/titanium clad cup was successfully drawn.

  6. Micro-hydromechanical deep drawing of metal cups with hydraulic pressure effects

    NASA Astrophysics Data System (ADS)

    Luo, Liang; Jiang, Zhengyi; Wei, Dongbin; Wang, Xiaogang; Zhou, Cunlong; Huang, Qingxue

    2018-03-01

    Micro-metal products have recently enjoyed high demand. In addition, metal microforming has drawn increasing attention due to its net-forming capability, batch manufacturing potential, high product quality, and relatively low equipment cost. Micro-hydromechanical deep drawing (MHDD), a typical microforming method, has been developed to take advantage of hydraulic force. With reduced dimensions, the hydraulic pressure development changes; accordingly, the lubrication condition changes from the macroscale to the microscale. A Voronoi-based finite element model is proposed in this paper to consider the change in lubrication in MHDD according to open and closed lubricant pocket theory. Simulation results agree with experimental results concerning drawing force. Changes in friction significantly affect the drawing process and the drawn cups. Moreover, defined wrinkle indexes have been shown to have a complex relationship with hydraulic pressure. High hydraulic pressure can increase the maximum drawing ratio (drawn cup height), whereas the surface finish represented by the wear is not linearly dependent on the hydraulic pressure due to the wrinkles.

  7. Numerical Simulation of Hydro-mechanical Deep Drawing — A Study on the Effect of Process Parameters on Drawability and Thickness Variation

    NASA Astrophysics Data System (ADS)

    Singh, Swadesh Kumar; Kumar, D. Ravi

    2005-08-01

    Hydro-mechanical deep drawing is a process for producing cup shaped parts with the assistance of a pressurized fluid. In the present work, numerical simulation of the conventional and counter pressure deep drawing processes has been done with the help of a finite element method based software. Simulation results were analyzed to study the improvement in drawability by using hydro-mechanical processes. The thickness variations in the drawn cups were analyzed and also the effect of counter pressure and oil gap on the thickness distribution was studied. Numerical simulations were also used for the die design, which combines both drawing and ironing processes in a single operation. This modification in the die provides high drawability, facilitates smooth material flow, gives more uniform thickness distribution and corrects the shape distortion.

  8. Constitutive Behavior and Deep Drawability of Three Aluminum Alloys Under Different Temperatures and Deformation Speeds

    NASA Astrophysics Data System (ADS)

    Panicker, Sudhy S.; Prasad, K. Sajun; Basak, Shamik; Panda, Sushanta Kumar

    2017-08-01

    In the present work, uniaxial tensile tests were carried out to evaluate the stress-strain response of AA2014, AA5052 and AA6082 aluminum alloys at four temperatures: 303, 423, 523 and 623 K, and three strain rates: 0.0022, 0.022 and 0.22 s-1. It was found that the Cowper-Symonds model was not a robust constitutive model, and it failed to predict the flow behavior, particularly the thermal softening at higher temperatures. Subsequently, a comparative study was made on the capability of Johnson-Cook (JC), modified Zerilli-Armstrong (m-ZA), modified Arrhenius (m-ARR) and artificial neural network (ANN) for modeling the constitutive behavior of all the three aluminum alloys under the mentioned strain rates and temperatures. Also, the improvement in formability of the materials was evaluated at an elevated temperature of 623 K in terms of cup height and maximum safe strains by conducting cylindrical cup deep drawing experiments under two different punch speeds of 4 and 400 mm/min. The cup heights increased during warm deep drawing due to thermal softening and increase in failure strains. Also, a small reduction in cup height was observed when the punch speed increased from 4 to 400 mm/min at 623 K. Hence, it was suggested to use high-speed deformation at elevated temperature to reduce both punch load and cycle time during the deep drawing process.

  9. Deep Drawing Behavior of CoCrFeMnNi High-Entropy Alloys

    NASA Astrophysics Data System (ADS)

    Bae, Jae Wung; Moon, Jongun; Jang, Min Ji; Ahn, Dong-Hyun; Joo, Soo-Hyun; Jung, Jaimyun; Yim, Dami; Kim, Hyoung Seop

    2017-09-01

    Herein, the deep drawability and deep drawing behavior of an equiatomic CoCrFeMnNi HEA and its microstructure and texture evolution are first studied for future applications. The CoCrFeMnNi HEA is successfully drawn to a limit drawing ratio (LDR) of 2.14, while the planar anisotropy of the drawn cup specimen is negligible. The moderate combination of strain hardening exponent and strain rate sensitivity and the formation of deformation twins in the edge region play important roles in successful deep drawing. In the meanwhile, the texture evolution of CoCrFeMnNi HEA has similarities with conventional fcc metals.

  10. The effect of elevated die temperature on deformation of deep drawn round metal cup

    NASA Astrophysics Data System (ADS)

    Basril, M. A. M.; Hafsyam, Y. M.; Azuddin, M.; Choudhury, I. A.

    2017-06-01

    One of the major considerations in the current deep drawing practice is the product quality. In this research, the effect of heating temperature on the drawability of the round metal cup has been investigated. Firstly, round metal cups of aluminium and mild steel were drawn from the blank diameters of 60 mm, 65 mm and 70 mm. The experiment conducted at room temperature first, then at 50°C and 100°C. The elongation of the major and minor strains along the cup profile after the process is measured and analysed. On the other hand, the defects from the experiment output and ABAQUS/CAE simulation are compared. The result from experiment shows that the highest major elongation is 11.64 mm and it is happened to a deep drawn aluminium round cup with LDR of 1.69 at temperature of 100°C. On the other hand, for deep drawn mild steel round cup, shows highest major elongation of 12.44 mm for a cup with LDR of 1.56 at 100°C. Both of these statements indicates that the higher temperature could improve the formability of the deep drawn parts besides reducing the probability of the defect to be happened.

  11. Analysis of Square Cup Deep-Drawing Test of Pure Titanium

    NASA Astrophysics Data System (ADS)

    Ogawa, Takaki; Ma, Ninshu; Ueyama, Minoru; Harada, Yasunori

    2016-08-01

    The prediction of formability of titunium is more difficult than steels since its strong anisotropy. If computer simulation can estimate the formability of titanium, we can select the optimal forming conditions. The purpose of this study was to acquire knowledge for the formability prediction by the computer simulation of the square cup deep-drawing of pure titanium. In this paper, the results of FEM analsis of pure titanium were compared with the experimental results to examine the analysis validity. We analyzed the formability of deepdrawing square cup of titanium by the FEM using solid elements. Compared the analysis results with the experimental results such as the forming shape, the punch load, and the thickness, the validity was confirmed. Further, through analyzing the change of the thickness around the forming corner, it was confirmed that the thickness increased to its maximum value during forming process at the stroke of 35mm more than the maximum stroke.

  12. Applying a punch with microridges in multistage deep drawing processes.

    PubMed

    Lin, Bor-Tsuen; Yang, Cheng-Yu

    2016-01-01

    The developers of high aspect ratio components aim to minimize the processing stages in deep drawing processes. This study elucidates the application of microridge punches in multistage deep drawing processes. A microridge punch improves drawing performance, thereby reducing the number of stages required in deep forming processes. As an example, the original eight-stage deep forming process for a copper cylindrical cup with a high aspect ratio was analyzed by finite element simulation. Microridge punch designs were introduced in Stages 4 and 7 to replace the original punches. In addition, Stages 3 and 6 were eliminated. Finally, these changes were verified through experiments. The results showed that the microridge punches reduced the number of deep drawing stages yielding similar thickness difference percentages. Further, the numerical and experimental results demonstrated good consistency in the thickness distribution.

  13. Modeling of the minimum variable blank holder force based on forming limit diagram (FLD) in deep drawing process

    NASA Astrophysics Data System (ADS)

    Candra, S.; Batan, I. M. L.; Berata, W.; Pramono, A. S.

    2017-11-01

    This paper presents the mathematical approach of minimum blank holder force to prevent wrinkling in deep drawing process of the cylindrical cup. Based on the maximum of minor-major strain ratio, the slab method was applied to determine the modeling of minimum variable blank holder force (VBHF) and it compared to FE simulation. The Tin steel sheet of T4-CA grade, with the thickness of 0.2 mm was used in this study. The modeling of minimum VBHF can be used as a simple reference to prevent wrinkling in deep drawing.

  14. Validation of the FEA of a deep drawing process with additional force transmission

    NASA Astrophysics Data System (ADS)

    Behrens, B.-A.; Bouguecha, A.; Bonk, C.; Grbic, N.; Vucetic, M.

    2017-10-01

    In order to meet requirements by automotive industry like decreasing the CO2 emissions, which reflects in reducing vehicles mass in the car body, the chassis and the powertrain, the continuous innovation and further development of existing production processes are required. In sheet metal forming processes the process limits and components characteristics are defined through the process specific loads. While exceeding the load limits, a failure in the material occurs, which can be avoided by additional force transmission activated in the deep drawing process before the process limit is achieved. This contribution deals with experimental investigations of a forming process with additional force transmission regarding the extension of the process limits. Based on FEA a tool system is designed and developed by IFUM. For this purpose, the steel material HCT600 is analyzed numerically. Within the experimental investigations, the deep drawing processes, with and without the additional force transmission are carried out. Here, a comparison of the produced rectangle cups is done. Subsequently, the identical deep drawing processes are investigated numerically. Thereby, the values of the punch reaction force and displacement are estimated and compared with experimental results. Thus, the validation of material model is successfully carried out on process scale. For further quantitative verification of the FEA results the experimental determined geometry of the rectangular cup is measured optically with ATOS system of the company GOM mbH and digitally compared with external software Geomagic®QualifyTM. The goal of this paper is the verification of the transferability of the FEA model for a conventional deep drawing process to a deep drawing process with additional force transmission with a counter punch.

  15. Study the effect of elevated dies temperature on aluminium and steel round deep drawing

    NASA Astrophysics Data System (ADS)

    Lean, Yeong Wei; Azuddin, M.

    2016-02-01

    Round deep drawing operation can only be realized by expensive multi-step production processes. To reduce the cost of processes while expecting an acceptable result, round deep drawing can be done at elevated temperature. There are 3 common problems which are fracture, wrinkling and earing of deep drawing a round cup. The main objective is to investigate the effect of dies temperature on aluminium and steel round deep drawing; with a sub-objective of eliminate fracture and reducing wrinkling effect. Experimental method is conducted with 3 different techniques on heating the die. The techniques are heating both upper and lower dies, heating only the upper dies, and heating only the lower dies. 4 different temperatures has been chosen throughout the experiment. The experimental result then will be compared with finite element analysis software. There is a positive result from steel material on heating both upper and lower dies, where the simulation result shows comparable as experimental result. Heating both upper and lower dies will be the best among 3 types of heating techniques.

  16. Effect of the Yield Stress and r-value Distribution on the Earing Profile of Cup Drawing with Yld2000-2d Yield Function

    NASA Astrophysics Data System (ADS)

    Lou, Yanshan; Bae, Gihyun; Lee, Changsoo; Huh, Hoon

    2010-06-01

    This paper deals with the effect of the yield stress and r-value distribution on the earing in the cup drawing. The anisotropic yield function, Yld2000-2d yield function, is selected to describe the anisotropy of two metal sheets, 719B and AA5182-O. The tool dimension is referred from the Benchmark problem of NUMISHEET'2002. The Downhill Simplex method is applied to identify the anisotropic coefficients in Yld2000-2d yield function. Simulations of the drawing process are performed to investigate the earing profile of two materials. The earing profiles obtained from simulations are compared with the analytical model developed by Hosford and Caddell. Simulations are conducted with respect to the change of the yield stress and r-value distribution, respectively. The correlation between the anisotropy and the earing tendency is investigated based on simulation data. Finally, the earing mechanism is analyzed through the deformation process of the blank during the cup deep drawing. It can be concluded that ears locate at angular positions with lower yield stress and higher r-value while the valleys appear at the angular position with higher yield stress and lower r-value. The effect of the yield stress distribution is more important for the cup height distribution than that of the r-value distribution.

  17. Springback optimization in automotive Shock Absorber Cup with Genetic Algorithm

    NASA Astrophysics Data System (ADS)

    Kakandikar, Ganesh; Nandedkar, Vilas

    2018-02-01

    Drawing or forming is a process normally used to achieve a required component form from a metal blank by applying a punch which radially draws the blank into the die by a mechanical or hydraulic action or combining both. When the component is drawn for more depth than the diameter, it is usually seen as deep drawing, which involves complicated states of material deformation. Due to the radial drawing of the material as it enters the die, radial drawing stress occurs in the flange with existence of the tangential compressive stress. This compression generates wrinkles in the flange. Wrinkling is unwanted phenomenon and can be controlled by application of a blank-holding force. Tensile stresses cause thinning in the wall region of the cup. Three main types of the errors occur in such a process are wrinkling, fracturing and springback. This paper reports a work focused on the springback and control. Due to complexity of the process, tool try-outs and experimentation may be costly, bulky and time consuming. Numerical simulation proves to be a good option for studying the process and developing a control strategy for reducing the springback. Finite-element based simulations have been used popularly for such purposes. In this study, the springback in deep drawing of an automotive Shock Absorber Cup is simulated with finite element method. Taguchi design of experiments and analysis of variance are used to analyze the influencing process parameters on the springback. Mathematical relations are developed to relate the process parameters and the resulting springback. The optimization problem is formulated for the springback, referring to the displacement magnitude in the selected sections. Genetic Algorithm is then applied for process optimization with an objective to minimize the springback. The results indicate that a better prediction of the springback and process optimization could be achieved with a combined use of these methods and tools.

  18. Effect of Hydraulic Pressure on Warm Hydro Mechanical Deep Drawing of Magnesium Alloy Sheet

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Wu, Linzhi; Yuan, Shijian

    The uniaxial tensile test and hydraulic bulging test of AZ31 magnesium alloy sheets were applied to study the influence of temperature on the material properties and obtain the forming limit curves at different temperatures. Numerical simulations of warm hydro mechanical deep drawing were carried out to investigate the effect of hydraulic pressure on the formability of a cylindrical cup, and the simplified hydraulic pressure profiles were used to simulate the loading procedure of hydraulic pressure. The optimal hydraulic pressure at different temperatures were given and verified by experimental studies at temperature 100°C and 170V.

  19. Analysis of earing behaviour in deep drawing of ASS 304 at elevated temperature

    NASA Astrophysics Data System (ADS)

    Gupta, Amit Kumar; Deole, Aditya; Kotkunde, Nitin; Singh, Swadesh Kumar; jella, Gangadhar

    2016-08-01

    Earing tendency in a deep drawn cup of circular blanks is one the most prominent characteristics observed due to anisotropy in a metal sheet. Such formation of uneven rim is mainly due to dissimilarity in yield stress as well as Lankford parameter (r- value) in different orientations. In this paper, an analytical function coupled with different yield functions viz., Hill 1948, Barlat 1989 and Barlat Yld 2000-2d has been used to provide an approximation of earing profile. In order to validate the results, material parameters for yield functions and hardening rule have been calibrated for ASS 304 at 250°C and deep drawing experiment is conducted to measure the earing profile. The predicted earing profiles based on analytical results have been validated using experimental earing profile. Based on this analysis, Barlat Yld 2000-2d has been observed to be a well suited yield model for deep drawing of ASS 304, which also confirms the reliability of analytical function for earing profile estimation.

  20. Formability analysis of aluminum alloys through deep drawing process

    NASA Astrophysics Data System (ADS)

    Pranavi, U.; Janaki Ramulu, Perumalla; Chandramouli, Ch; Govardhan, Dasari; Prasad, PVS. Ram

    2016-09-01

    Deep drawing process is a significant metal forming process used in the sheet metal forming operations. From this process complex shapes can be manufactured with fewer defects. Deep drawing process has different effectible process parameters from which an optimum level of parameters should be identified so that an efficient final product with required mechanical properties will be obtained. The present work is to evaluate the formability of Aluminum alloy sheets using deep drawing process. In which effects of punch radius, lubricating conditions, die radius, and blank holding forces on deep drawing process observed for AA 6061 aluminum alloy sheet of 2 mm thickness. The numerical simulations are performed for deep drawing of square cups using three levels of aforesaid parameters like lubricating conditions and blank holding forces and two levels of punch radii and die radii. For numerical simulation a commercial FEM code is used in which Hollomon's power law and Hill's 1948 yield criterions are implemented. The deep drawing setup used in the FEM code is modeled using a CAD tool by considering the modeling requirements from the literature. Two different strain paths (150x150mm and 200x200mm) are simulated. Punch forces, thickness distributions and dome heights are evaluated for all the conditions. In addition failure initiation and propagation is also observed. From the results, by increasing the coefficient of friction and blank holding force, punch force, thickness distribution and dome height variations are observed. The comparison has done and the optimistic parameters were suggested from the results. From this work one can predict the formability for different strain paths without experimentation.

  1. AISI/DOE Technology Roadmap Program: Cold Work Embrittlement of Interstitial Free Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John T Bowker; Pierre Martin

    2002-10-31

    This work addresses the issues of measurement of secondary cold work embrittlement (SCWE) of an IF steel in deep-drawn parts using laboratory tests, and its correlation with real part fracture. It aimed at evaluating the influence of the steel chemistry and processing condition, microstructure, and test conditions, on SCWE as well as the effect of SCWE on fatigue properties. Size 6-in. cups produced with various draw ratios or trimmed at different heights were tested to determine the ductile-to-brittle-transition temperature (DBTT) as a function of strain. The 2-in. cup/expansion test, bend test and fracture of notched specimens were also used tomore » generate information complementary to that provided by the 6-inch cup/expansion test. The relationship between laboratory tests and fracture in real parts was established by testing large-scale parts. The fatigue behavior was investigated in the as-rolled and deep drawn (high stain) conditions, using prestrained specimens taken from the wall of a formed part.« less

  2. In-Situ-measurement of restraining forces during forming of rectangular cups

    NASA Astrophysics Data System (ADS)

    Singer, M.; Liewald, M.

    2016-11-01

    This contribution introduces a new method for evaluating the restraining forces during forming of rectangular cups with the goal of eliminating the disadvantages of the currently used scientifically established measurement procedures. With this method forming forces are measured indirectly by the elastic deformation of die structure caused by locally varying tribological system. Therefore, two sensors were integrated into the punch, which measure the restraining forces during the forming process. Furthermore, it was possible to evaluate the effects of different lubricants showing the time dependent trend as a function of stroke during the forming of the materials DP600 and DC04. A main advantage of this testing method is to get real friction corresponding data out of the physical deep drawing process as well as the measurement of real acting restraining forces at different areas of the deep drawing part by one single test. Measurement results gained by both sensors have been integrated into LS-Dyna simulation in which the coefficient of friction was regarded as a function of time. The simulated and deep drawn parts afterwards are analysed and compared to specific areas with regard to locally measured thickness of part. Results show an improvement of simulation quality when using locally varying, time dependent coefficients of friction compared to commonly used constant values.

  3. Formability analysis of austenitic stainless steel-304 under warm conditions

    NASA Astrophysics Data System (ADS)

    Lade, Jayahari; Singh, Swadesh Kumar; Banoth, Balu Naik; Gupta, Amit Kumar

    2013-12-01

    A warm deep drawing process of austenitic stainless steel-304 (ASS-304) of circular blanks with coupled ther mal analysis is studied in this article. 65 mm blanks were deep drawn at different temperatures and thickness distribution is experimentally measured after cutting the drawn component into two halves. The process is simulated using explicit fin ite element code LS-DYNA. A Barlat 3 parameter model is used in the simulation, as the material is anisotropic up to 30 0°C. Material properties for the simulation are determined at different temperatures using a 5 T UTM coupled with a furn ace. In this analysis constant punch speed and variable blank holder force (BHF) is applied to draw cups without wrinkle.

  4. Characterization of Tensile Properties, Limiting Strains, and Deep Drawing Behavior of AA5754-H22 Sheet at Elevated Temperature

    NASA Astrophysics Data System (ADS)

    Panicker, Sudhy S.; Singh, Har Govind; Panda, Sushanta Kumar; Dashwood, Richard

    2015-11-01

    Automotive industries are very much interested in characterization of formability improvement of aluminum alloys at elevated temperatures before designing tools, heating systems, and processing sequences for fabrication of auto-body panels by warm forming technology. In this study, tensile tests of AA5754-H22 aluminum alloy were carried out at five different temperatures and three different strain rates to investigate the deformation behavior correlating with Cowper-Symonds constitutive equation. Laboratory scale warm forming facilities were designed and fabricated to perform limiting dome height and deep drawing tests to evaluate forming limit strains and drawability of sheet metal at different tool temperatures. The forming limit strain and dome height improved significantly when both the die and punch were heated to 200 °C. Remarkable improvement in deep drawn cup depth was observed when die and punch temperatures were maintained at 200 and 30 °C, respectively, producing a non-isothermal temperature gradient of approximately 93 °C across the blank from flange to center. The forming behavior at different isothermal and non-isothermal conditions were predicted successfully using a thermo-mechanical FE model incorporating temperature-dependent properties in Barlat-89 yield criterion coupled with Cowper-Symonds hardening model, and the thinning/failure location in deformed cups were validated implementing the experimental limiting strains as damage model.

  5. Experimental analysis of the sheet metal forming behavior of newly developed press hardening steels

    NASA Astrophysics Data System (ADS)

    Meza-García, Enrique; Kräusel, Verena; Landgrebe, Dirk

    2018-05-01

    The aim of this work was the characterization of the newly developed press hardening sheet alloys 1800 PHS and 2000 PHS developed by SSAB with regard to their hot forming behavior on the basis of the experimental determination of relevant mechanical and technological properties. For this purpose conventional and non-conventional sheet metal testing methods were used. To determine the friction coefficient, the strip drawing test was applied, while the deep drawing cup test was used to determine the maximum draw depth. Finally, a V-bending test was carried out to evaluate the springback behavior of the investigated alloys by varying the blank temperature and quenching media. This work provides a technological guideline for the production of press hardened sheet parts made of these investigated sheet metals.

  6. Cup-Drawing Behavior of High-Strength Steel Sheets Containing Different Volume Fractions of Martensite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Shi-Hoon; Kim, Dae-Wan; Yang, Hoe-Seok

    Planar anisotropy and cup-drawing behavior were investigated for high-strength steel sheets containing different volume fractions of martensite. Macrotexture analysis using XRD was conducted to capture the effect of crystallographic orientation on the planar anisotropy of high-strength steel sheets. A phenomenological yield function, Yld96, which accounts for the anisotropy of yield stress and r-values, was implemented into ABAQUS using the user subroutine UMAT. Cup drawing of high-strength steel sheets was simulated using the FEM code. The profiles of earing and thickness strain were compared with the experimentally measured results.

  7. Experimental formability analysis of bondal sandwich sheet

    NASA Astrophysics Data System (ADS)

    Kami, Abdolvahed; Banabic, Dorel

    2018-05-01

    Metal/polymer/metal sandwich sheets have recently attracted the interests of industries like automotive industry. These sandwich sheets have superior properties over single-layer metallic sheets including good sound and vibration damping and light weight. However, the formability of these sandwich sheets should be enhanced which requires more research. In this paper, the formability of Bondal sheet (DC06/viscoelastic polymer/DC06 sandwich sheet) was studied through different types of experiments. The mechanical properties of Bondal were determined by uniaxial tensile tests. Hemispherical punch stretching and hydraulic bulge tests were carried out to determine the forming limit diagram (FLD) of Bondal. Furthermore, cylindrical and square cup drawing tests were performed in dry and oil lubricated conditions. These tests were conducted at different blank holding forces (BHFs). An interesting observation about Bondal sheet deep drawing was obtaining of higher drawing depths at dry condition in comparison with oil-lubricated condition.

  8. Facial expression drawings and the full cup test: valid tools for the measurement of swelling after dental surgery.

    PubMed

    Al-Samman, A A; Othman, H A

    2017-01-01

    Assessment of postoperative swelling is subjective and depends on the patient's opinion. The aim of this study was to evaluate the validity of facial expression drawings and the full cup test and to compare their performance with that of other scales in measuring postoperative swelling. Fifty patients who had one of several procedures were included. All patients were asked to fill in a form for six days postoperatively (including the day of operation) that contained four scales to rate the amount of swelling: facial expression drawings, the full cup test, the visual analogue scale (VAS), and the verbal rating scale (VRS). Seven patients did not know how to use some of the scales. However, all patients successfully used the facial expression drawings. There was a significant difference between the scale that patients found easiest to use and the others (p<0.008). Fourteen patients selected facial expression drawings and five the VRS. The results showed that the correlations between the scales were good (p<0.01). Facial expression drawings and the full cup test are valid tools and could be used to assess postoperative swelling interchangeably with other scales for rating swelling, and some patients found facial expression drawings were the easiest to use. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Estimating surface hardening profile of blank for obtaining high drawing ratio in deep drawing process using FE analysis

    NASA Astrophysics Data System (ADS)

    Tan, C. J.; Aslian, A.; Honarvar, B.; Puborlaksono, J.; Yau, Y. H.; Chong, W. T.

    2015-12-01

    We constructed an FE axisymmetric model to simulate the effect of partially hardened blanks on increasing the limiting drawing ratio (LDR) of cylindrical cups. We partitioned an arc-shaped hard layer into the cross section of a DP590 blank. We assumed the mechanical property of the layer is equivalent to either DP980 or DP780. We verified the accuracy of the model by comparing the calculated LDR for DP590 with the one reported in the literature. The LDR for the partially hardened blank increased from 2.11 to 2.50 with a 1 mm depth of DP980 ring-shaped hard layer on the top surface of the blank. The position of the layer changed with drawing ratios. We proposed equations for estimating the inner and outer diameters of the layer, and tested its accuracy in the simulation. Although the outer diameters fitted in well with the estimated line, the inner diameters are slightly less than the estimated ones.

  10. In-situ-measurement of the friction coefficient in the deep drawing process

    NASA Astrophysics Data System (ADS)

    Recklin, V.; Dietrich, F.; Groche, P.

    2017-09-01

    The surface texture plays an important role in the tribological behaviour of deep drawn components. It influences both the process of sheet metal forming as well as the properties for post processing, such as paint appearance, bonding, or corrosion tendency. During the forming process, the texture of the sheet metal and therefore its friction coefficient, changes due to process related strains. This contribution focuses on the development and validation of a tool to investigate the friction coefficient of the flange region of deep drawn components. The influence of biaxial strain on the friction coefficient will be quantified through a comparison of the experimental results with a conventional friction test (stand). The presented method will be applied on a cup drawing test, using a segmented and sensor-monitored blankholder. This setup allows the measurement of the friction coefficient in-situ without simplification of the real process. The experiments were carried out using DX 56D+Z as sheet metal and PL61 as lubricant. The results show a characteristic change in the friction coefficient over the displacement of the punch, which is assumed to be caused by strain induced change of the surface texture.

  11. Experimental and Numerical Studies on Isothermal and Non-isothermal Deep Drawing of IS 513 CR3 Steel Sheets

    NASA Astrophysics Data System (ADS)

    Mayavan, T.; Karthikeyan, L.; Senthilkumar, V. S.

    2016-11-01

    The present work aims to investigate the effects of the temperature gradient developed within the tool profiles on the formability of IS 513 CR3-grade steel sheets using the cup drawing test. The deformation characteristics of steel sheets were analyzed by comparing the thicknesses in various regions of the formed cup and also the limiting drawing ratios (LDR). Finite element simulations were carried out to predict the behavior of the steel sheets in isothermal and non-isothermal forming using Abaqus/Standard 6.12-1. An analytical model created by Kim was used to validate the experimental and finite element analysis (FEA) results on identical process parameters. Both the FEA and analytical modeling results showed that formability improvement is possible in warm forming; the findings are in good agreement with the experimental results in determining the locations and values of excessive thinning. The results also indicated that formability improvement cannot be achieved by keeping the tooling temperature at the same level. The LDR increased by around 9.5% in isothermal forming and by 19% in non-isothermal forming (with the punch maintained at a lower temperature compared with the die and blank holder). In addition, the fractured surfaces of unsuccessfully formed samples were analyzed using scanning electron microscopy. Metallographic investigations confirmed that the fracture mechanism during the forming of IS 513 CR3-grade steel sheets depends on the brittleness, strain hardening value, forming temperature, and magnitude of stresses developed.

  12. Influence of Drawbeads in Deep-Drawing of Plane-Strain Channel Sections: Experimental and FE Analysis

    NASA Astrophysics Data System (ADS)

    Oliveira, M. C.; Baptista, A. J.; Alves, J. L.; Menezes, L. F.; Green, D. E.; Ghaei, A.

    2007-05-01

    The main purpose of the "Numisheet'05 Benchmark♯3: Channel Draw/Cylindrical Cup" was to evaluate the forming characteristics of materials in multi-stage processes. The concept was to verify the strain fields achieved during the two stage forming process and also to test the ability of numerical models to predict both strain and stress fields. The first stage consisted of forming channel sections in an industrial-scale channel draw die. The material that flows through the drawbead and over the die radii into the channel sidewalls is prestrained by cyclic bending and unbending. The prestrained channel sidewalls are subsequently cut and subjected to near plane-strain Marciniak-style cup test. This study emphasizes the analysis of the first stage process, the Channel Draw, since accurate numerical results for the first stage forming and springback are essential to guarantee proper initial state variables for the subsequent stage simulation. Four different sheet materials were selected: mild steel AKDQ-HDG, high strength steel HSLA-HDG, dual phase steel DP600-HDG and an aluminium alloy AA6022-T43. The four sheet materials were formed in the same channel draw die, but with drawbead penetrations of 25%, 50% and 100%. This paper describes the testing and measurement procedures for the numerical simulation of these conditions with DD3IMP FE code. A comparison between experimental and numerical simulation results for the first stage is presented. The experimental results indicate that an increase in drawbead penetration is accompanied by a general decrease in springback, with both sidewall radius of curvature and the sidewall angle increasing with increasing drawbead penetration. An exception to this trend occurs at the shallowest bead penetration: the radius of curvature in the sidewall is larger than expected. The sequence of cyclic tension and compression is numerically studied for each drawbead penetration in order to investigate this phenomenon.

  13. Alignment Pins for Assembling and Disassembling Structures

    NASA Technical Reports Server (NTRS)

    Campbell, Oliver C.

    2008-01-01

    Simple, easy-to-use, highly effective tooling has been devised for maintaining alignment of bolt holes in mating structures during assembly and disassembly of the structures. The tooling was originally used during removal of a body flap from the space shuttle Atlantis, in which misalignments during removal of the last few bolts could cause the bolts to bind in their holes. By suitably modifying the dimensions of the tooling components, the basic design of the tooling can readily be adapted to other structures that must be maintained in alignment. The tooling includes tapered, internally threaded alignment pins designed to fit in the bolt holes in one of the mating structures, plus a draw bolt and a cup that are used to install or remove each alignment pin. In preparation for disassembly of two mating structures, external supports are provided to prevent unintended movement of the structures. During disassembly of the structures, as each bolt that joins the structures is removed, an alignment pin is installed in its place. Once all the bolts have been removed and replaced with pins, the pins maintain alignment as the structures are gently pushed or pulled apart on the supports. In assembling the two structures, one reverses the procedure described above: pins are installed in the bolt holes, the structures are pulled or pushed together on the supports, then the pins are removed and replaced with bolts. The figure depicts the tooling and its use. To install an alignment pin in a bolt hole in a structural panel, the tapered end of the pin is inserted from one side of the panel, the cup is placed over the pin on the opposite side of the panel, the draw bolt is inserted through the cup and threaded into the pin, the draw bolt is tightened to pull the pin until the pin is seated firmly in the hole, then the draw bolt and cup are removed, leaving the pin in place. To remove an alignment pin, the cup is placed over the pin on the first-mentioned side of the panel, the draw bolt is inserted through the cup and threaded into the pin, then the draw bolt is tightened to pull the pin out of the hole.

  14. Effects of process variation in short cycle stretch forming in beverage can production

    NASA Astrophysics Data System (ADS)

    Schneider, Matthias; Liewald, Mathias

    2016-10-01

    Short Cycle Stretch Forming (SCS) is an innovative stretch forming technology developed at the Institute for Metal Forming Technology (IFU) at the University of Stuttgart. The SCS technology combines plane pre-stretching and deep drawing operations within the same stroke of press ram. Material is yielding from the inner to the outer part of the sheet. The sheet thickness is reduced and denting resistance and yield stress are increased due to hardening effects. SCS-Technology is enhanced due to rotational-symmetrical bodies by applying this technology to a cupping process in tinplate can production. A process simulation for SCS-Cupping processes was conducted. Based on these results a tool was manufactured and commissioned. Experimental results showed that material yields from the middle of the blank to the outer area of the cup wall. Due to the volume of material, the initial diameter can be reduced and material costs can be saved. In this paper different process settings and their effect on the amount of material, which yielded from the middle of the blank to its outside, are observed in a number of experimental series. A blank holder is added to the process in order to avoid wrinkling. The influence of this additional blank holder is therefore investigated in a first experimental set-up by varying blank holder force. In a further investigation the effects of two materials with different thicknesses is observed. Finally, an experimental series is conducted to observe the effect of blank diameter on the SCS-Cupping process. The results of this paper show that SCS-Cupping offers a promising potential for material savings and outline main effects for this technology.

  15. 78 FR 40396 - Safety Zone; America's Cup Safety Zone and No Loitering Area, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-05

    ... were issued for this series of races. Only after the Coast Guard learned that the racing vessels.... Additionally, members of the deep-draft commercial shipping community raised concerns pertaining to the... associated with the viewing of the America's Cup in vicinity of buoys ``1'' and ``2'', marking the deep water...

  16. Prediction of fracture initiation in square cup drawing of DP980 using an anisotropic ductile fracture criterion

    NASA Astrophysics Data System (ADS)

    Park, N.; Huh, H.; Yoon, J. W.

    2017-09-01

    This paper deals with the prediction of fracture initiation in square cup drawing of DP980 steel sheet with the thickness of 1.2 mm. In an attempt to consider the influence of material anisotropy on the fracture initiation, an uncoupled anisotropic ductile fracture criterion is developed based on the Lou—Huh ductile fracture criterion. Tensile tests are carried out at different loading directions of 0°, 45°, and 90° to the rolling direction of the sheet using various specimen geometries including pure shear, dog-bone, and flat grooved specimens so as to calibrate the parameters of the proposed fracture criterion. Equivalent plastic strain distribution on the specimen surface is computed using Digital Image Correlation (DIC) method until surface crack initiates. The proposed fracture criterion is implemented into the commercial finite element code ABAQUS/Explicit by developing the Vectorized User-defined MATerial (VUMAT) subroutine which features the non-associated flow rule. Simulation results of the square cup drawing test clearly show that the proposed fracture criterion is capable of predicting the fracture initiation with sufficient accuracy considering the material anisotropy.

  17. Model Identification and FE Simulations: Effect of Different Yield Loci and Hardening Laws in Sheet Forming

    NASA Astrophysics Data System (ADS)

    Flores, P.; Duchêne, L.; Lelotte, T.; Bouffioux, C.; El Houdaigui, F.; Van Bael, A.; He, S.; Duflou, J.; Habraken, A. M.

    2005-08-01

    The bi-axial experimental equipment developed by Flores enables to perform Baushinger shear tests and successive or simultaneous simple shear tests and plane-strain tests. Such experiments and classical tensile tests investigate the material behavior in order to identify the yield locus and the hardening models. With tests performed on two steel grades, the methods applied to identify classical yield surfaces such as Hill or Hosford ones as well as isotropic Swift type hardening or kinematic Armstrong-Frederick hardening models are explained. Comparison with the Taylor-Bishop-Hill yield locus is also provided. The effect of both yield locus and hardening model choice will be presented for two applications: Single Point Incremental Forming (SPIF) and a cup deep drawing.

  18. [Analysis on the adverse events of cupping therapy in the application].

    PubMed

    Zhou, Xin; Ruan, Jing-wen; Xing, Bing-feng

    2014-10-01

    The deep analysis has been done on the cases of adverse events and common injury of cupping therapy encountered in recent years in terms of manipulation and patient's constitution. The adverse events of cupping therapy are commonly caused by improper manipulation of medical practitioners, ignoring contraindication and patient's constitution. Clinical practitioners should use cupping therapy cautiously, follow strictly the rules of standard manipulation and medical core system, pay attention to the contraindication and take strict precautions against the occurrence of adverse events.

  19. Pregnancy test

    MedlinePlus

    For the urine test, you urinate into a cup. For the blood test, the health care provider uses a needle and syringe to draw blood from your vein into a tube. Any discomfort you might feel from the blood draw will only last a few seconds.

  20. On Using Homogeneous Polynomials To Design Anisotropic Yield Functions With Tension/Compression Symmetry/Assymetry

    NASA Astrophysics Data System (ADS)

    Soare, S.; Yoon, J. W.; Cazacu, O.

    2007-05-01

    With few exceptions, non-quadratic homogeneous polynomials have received little attention as possible candidates for yield functions. One reason might be that not every such polynomial is a convex function. In this paper we show that homogeneous polynomials can be used to develop powerful anisotropic yield criteria, and that imposing simple constraints on the identification process leads, aposteriori, to the desired convexity property. It is shown that combinations of such polynomials allow for modeling yielding properties of metallic materials with any crystal structure, i.e. both cubic and hexagonal which display strength differential effects. Extensions of the proposed criteria to 3D stress states are also presented. We apply these criteria to the description of the aluminum alloy AA2090T3. We prove that a sixth order orthotropic homogeneous polynomial is capable of a satisfactory description of this alloy. Next, applications to the deep drawing of a cylindrical cup are presented. The newly proposed criteria were implemented as UMAT subroutines into the commercial FE code ABAQUS. We were able to predict six ears on the AA2090T3 cup's profile. Finally, we show that a tension/compression asymmetry in yielding can have an important effect on the earing profile.

  1. AFTERRISE: Deep Body Temperature Following Exercise

    DTIC Science & Technology

    1992-04-01

    Egalement, les effets de la posture et des v~tements durant la r~cup~ration et la temperature de la salle de r~cup~ration furent examines. Cinq hommes...une chemise a manches courtes). Les tempdratures rectales et de la peau furent mesurdes & chaque minute durant les exercices et la r6cupdration...Ndcnillll~ l OLen 1+ 1DNfnce na~on~e :x DTIC Ss ELECTE FEB 5 1993DI C AFTERRISE: DEEP BODY TEMPERATURE FOLLOWING EXERCISE (U) by S. Tuck and A.A

  2. Combining morphometric features and convolutional networks fusion for glaucoma diagnosis

    NASA Astrophysics Data System (ADS)

    Perdomo, Oscar; Arevalo, John; González, Fabio A.

    2017-11-01

    Glaucoma is an eye condition that leads to loss of vision and blindness. Ophthalmoscopy exam evaluates the shape, color and proportion between the optic disc and physiologic cup, but the lack of agreement among experts is still the main diagnosis problem. The application of deep convolutional neural networks combined with automatic extraction of features such as: the cup-to-disc distance in the four quadrants, the perimeter, area, eccentricity, the major radio, the minor radio in optic disc and cup, in addition to all the ratios among the previous parameters may help with a better automatic grading of glaucoma. This paper presents a strategy to merge morphological features and deep convolutional neural networks as a novel methodology to support the glaucoma diagnosis in eye fundus images.

  3. Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

    PubMed

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-02-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.

  4. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    PubMed Central

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-01-01

    Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150

  5. Cupping for Treating Pain: A Systematic Review

    PubMed Central

    Kim, Jong-In; Lee, Myeong Soo; Lee, Dong-Hyo; Boddy, Kate; Ernst, Edzard

    2011-01-01

    The objective of this study was to assess the evidence for or against the effectiveness of cupping as a treatment option for pain. Fourteen databases were searched. Randomized clinical trials (RCTs) testing cupping in patients with pain of any origin were considered. Trials using cupping with or without drawing blood were included, while trials comparing cupping with other treatments of unproven efficacy were excluded. Trials with cupping as concomitant treatment together with other treatments of unproven efficacy were excluded. Trials were also excluded if pain was not a central symptom of the condition. The selection of studies, data extraction and validation were performed independently by three reviewers. Seven RCTs met all the inclusion criteria. Two RCTs suggested significant pain reduction for cupping in low back pain compared with usual care (P < .01) and analgesia (P < .001). Another two RCTs also showed positive effects of cupping in cancer pain (P < .05) and trigeminal neuralgia (P < .01) compared with anticancer drugs and analgesics, respectively. Two RCTs reported favorable effects of cupping on pain in brachialgia compared with usual care (P = .03) or heat pad (P < .001). The other RCT failed to show superior effects of cupping on pain in herpes zoster compared with anti-viral medication (P = .065). Currently there are few RCTs testing the effectiveness of cupping in the management of pain. Most of the existing trials are of poor quality. Therefore, more rigorous studies are required before the effectiveness of cupping for the treatment of pain can be determined. PMID:19423657

  6. On Using Homogeneous Polynomials To Design Anisotropic Yield Functions With Tension/Compression Symmetry/Assymetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soare, S.; Cazacu, O.; Yoon, J. W.

    With few exceptions, non-quadratic homogeneous polynomials have received little attention as possible candidates for yield functions. One reason might be that not every such polynomial is a convex function. In this paper we show that homogeneous polynomials can be used to develop powerful anisotropic yield criteria, and that imposing simple constraints on the identification process leads, aposteriori, to the desired convexity property. It is shown that combinations of such polynomials allow for modeling yielding properties of metallic materials with any crystal structure, i.e. both cubic and hexagonal which display strength differential effects. Extensions of the proposed criteria to 3D stressmore » states are also presented. We apply these criteria to the description of the aluminum alloy AA2090T3. We prove that a sixth order orthotropic homogeneous polynomial is capable of a satisfactory description of this alloy. Next, applications to the deep drawing of a cylindrical cup are presented. The newly proposed criteria were implemented as UMAT subroutines into the commercial FE code ABAQUS. We were able to predict six ears on the AA2090T3 cup's profile. Finally, we show that a tension/compression asymmetry in yielding can have an important effect on the earing profile.« less

  7. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.

    PubMed

    Li, Zhixi; He, Yifan; Keel, Stuart; Meng, Wei; Chang, Robert T; He, Mingguang

    2018-03-02

    To assess the performance of a deep learning algorithm for detecting referable glaucomatous optic neuropathy (GON) based on color fundus photographs. A deep learning system for the classification of GON was developed for automated classification of GON on color fundus photographs. We retrospectively included 48 116 fundus photographs for the development and validation of a deep learning algorithm. This study recruited 21 trained ophthalmologists to classify the photographs. Referable GON was defined as vertical cup-to-disc ratio of 0.7 or more and other typical changes of GON. The reference standard was made until 3 graders achieved agreement. A separate validation dataset of 8000 fully gradable fundus photographs was used to assess the performance of this algorithm. The area under receiver operator characteristic curve (AUC) with sensitivity and specificity was applied to evaluate the efficacy of the deep learning algorithm detecting referable GON. In the validation dataset, this deep learning system achieved an AUC of 0.986 with sensitivity of 95.6% and specificity of 92.0%. The most common reasons for false-negative grading (n = 87) were GON with coexisting eye conditions (n = 44 [50.6%]), including pathologic or high myopia (n = 37 [42.6%]), diabetic retinopathy (n = 4 [4.6%]), and age-related macular degeneration (n = 3 [3.4%]). The leading reason for false-positive results (n = 480) was having other eye conditions (n = 458 [95.4%]), mainly including physiologic cupping (n = 267 [55.6%]). Misclassification as false-positive results amidst a normal-appearing fundus occurred in only 22 eyes (4.6%). A deep learning system can detect referable GON with high sensitivity and specificity. Coexistence of high or pathologic myopia is the most common cause resulting in false-negative results. Physiologic cupping and pathologic myopia were the most common reasons for false-positive results. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Strain and mechanical properties of the VCM multilayer sheet and their composites using the digital speckle correlation method.

    PubMed

    Zhang, Dehai; Xie, Guizhong; Li, Yanqin; Liu, Jianxiu

    2015-09-01

    The digital speckle correlation method (DSCM) is introduced to solve the challenging problems in the related geometric measurement. Theoretical calculations of strain are deduced using the DSCM. Corresponding strains along x and y directions are obtained from uniaxial tension experiments and digital speckle measurements, using the VCM nondeep drawing multilayer sheet, the VCM deep-drawing multilayer sheet, clad films, nondeep drawing substrate, and deep-drawing substrate sheet as the targeted experimental objects. The results show that the maximum strains along the x direction of the VCM nondeep drawing multilayer sheet, the VCM deep-drawing multilayer sheet, clad film, nondeep drawing substrate, and deep-drawing substrate sheet are 68.473%, 48.632%, 91.632%, 50.784% and 40.068%, respectively, while the maximum strains along the y direction are -2.657%, -15.381%, 2.826%, -9.780% and -7.783%, respectively. The mechanical properties of the VCM multilayer sheet are between those of the substrate and clad film, while mechanical properties of the VCM deep-drawing multilayer sheet are superior to those of the VCM nondeep drawing multi-layer sheet.

  9. Anisotropic yield function capable of predicting eight ears

    NASA Astrophysics Data System (ADS)

    Yoon, J. H.; Cazacu, O.

    2011-08-01

    Deep drawing of a cylindrical cup from a rolled sheet is one of the typical forming operations where the effect of this anisotropy is most evident. Indeed, it is well documented in the literature that the number of ears and the shape of the earing pattern correlate with the r-values profile. For the strongly textured aluminum alloy AA 5042 (Numisheet Benchmark 2011), the experimental r-value distribution has two minima between the rolling and transverse direction data provided for this show that the r-value along the transverse direction (TD) is five times larger than the value corresponding to the rolling direction. Therefore, it is expected that there are more that the earing profile has more than four ears. The main objective of this paper is to assess whether a new form of CPB06ex2 yield function (Plunkett et al. (2008)) tailored for metals with no tension-compression asymmetry is capable of predicting more than four ears for this material.

  10. Numerical and Experimental Study on Manufacture of a Novel High-Capacity Engine Oil Pan Subjected to Hydro-Mechanical Deep Drawing

    NASA Astrophysics Data System (ADS)

    Chen, D. Y.; Xu, Y.; Zhang, S. H.; El-Aty, A. Abd; Ma, Y.

    2017-09-01

    The oil pan is equipped at the bottom of engine crankcase of the automobile to prevent impurity and collect the lubrication oil from the surfaces of the engine which is helpful for heat dissipation and oxidation prevention. The present study aims at manufacturing a novel high-capacity engine oil pan, which is considered as a complex shaped component with features of thin wall, large size and asymmetric deep cavity through both numerical and experimental methods. The result indicated that it is difficult to form the current part through the common deep drawing process. Accordingly, the hydro-mechanical deep drawing technology was conducted, which consisted of two steps, previous local drawing and the final integral deep drawing with hydraulic pressure. The finite element analysis (FEA) was carried out to investigate the influence of initial blank dimension and the key process parameters such as loading path, draw-bead force and fillet radius on the formability of the sheet blank. Compared with the common deep drawing, the limit drawing ratio by hydro-mechanical deep drawing can be increased from 2.34 to 2.77, while the reduction in blank wall thickness can be controlled in the range of 28%. The formability is greatly improved without any defects such as crack and wrinkle by means of parameters optimisation. The results gained from simulation keep a reasonable agreement with that obtained from experiment trials.

  11. Inverse Analysis to Formability Design in a Deep Drawing Process

    NASA Astrophysics Data System (ADS)

    Buranathiti, Thaweepat; Cao, Jian

    Deep drawing process is an important process adding values to flat sheet metals in many industries. An important concern in the design of a deep drawing process generally is formability. This paper aims to present the connection between formability and inverse analysis (IA), which is a systematical means for determining an optimal blank configuration for a deep drawing process. In this paper, IA is presented and explored by using a commercial finite element software package. A number of numerical studies on the effect of blank configurations to the quality of a part produced by a deep drawing process were conducted and analyzed. The quality of the drawing processes is numerically analyzed by using an explicit incremental nonlinear finite element code. The minimum distance between elemental principal strains and the strain-based forming limit curve (FLC) is defined as tearing margin to be the key performance index (KPI) implying the quality of the part. The initial blank configuration has shown that it plays a highly important role in the quality of the product via the deep drawing process. In addition, it is observed that if a blank configuration is not greatly deviated from the one obtained from IA, the blank can still result a good product. The strain history around the bottom fillet of the part is also observed. The paper concludes that IA is an important part of the design methodology for deep drawing processes.

  12. Computer Aided Process Planning for Non-Axisymmetric Deep Drawing Products

    NASA Astrophysics Data System (ADS)

    Park, Dong Hwan; Yarlagadda, Prasad K. D. V.

    2004-06-01

    In general, deep drawing products have various cross-section shapes such as cylindrical, rectangular and non-axisymmetric shapes. The application of the surface area calculation to non-axisymmetric deep drawing process has not been published yet. In this research, a surface area calculation for non-axisymmetric deep drawing products with elliptical shape was constructed for a design of blank shape of deep drawing products by using an AutoLISP function of AutoCAD software. A computer-aided process planning (CAPP) system for rotationally symmetric deep drawing products has been developed. However, the application of the system to non-axisymmetric components has not been reported yet. Thus, the CAPP system for non-axisymmetric deep drawing products with elliptical shape was constructed by using process sequence design. The system developed in this work consists of four modules. The first is recognition of shape module to recognize non-axisymmetric products. The second is a three-dimensional (3-D) modeling module to calculate the surface area for non-axisymmetric products. The third is a blank design module to create an oval-shaped blank with the identical surface area. The forth is a process planning module based on the production rules that play the best important role in an expert system for manufacturing. The production rules are generated and upgraded by interviewing field engineers. Especially, the drawing coefficient, the punch and die radii for elliptical shape products are considered as main design parameters. The suitability of this system was verified by applying to a real deep drawing product. This CAPP system constructed would be very useful to reduce lead-time for manufacturing and improve an accuracy of products.

  13. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty

    PubMed Central

    2012-01-01

    Background and purpose Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. Methods We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip Arthroplasty Register (SHAR). 2 such cup designs were identified: Harris-Galante and Trilogy, both available either with or without HA coating. These cups had been used as revision components in 1,780 revisions of total hip arthroplasties (THA) between 1986 and 2009. A Cox proportional hazards model including the type of coating, age at index revision, sex, cause of cup revision, cup design, the use of bone graft at the revision procedure, and the type of cup fixation at primary THA were used to calculate adjusted risk ratios (RRs with 95% CI) for re-revision for any reason or due to aseptic loosening. Results 71% of the cups were coated with HA and 29% were uncoated. At a mean follow-up time of 6.9 (0–24) years, 159 (9%) of all 1,780 cups had been re-revised, mostly due to aseptic loosening (5%), dislocation (2%), or deep infection (1%). HA coating had no significant influence on the risk of re-revision of the cup for any reason (RR = 1.4, CI: 0.9–2.0) or due to aseptic loosening (RR = 1.1, 0.6–1.9). In contrast, HA coating was found to be a risk factor for isolated liner re-revision for any reason (RR = 1.8, CI: 1.01–3.3). Age below 60 years at the index cup revision, dislocation as the cause of the index cup revision, uncemented cup fixation at primary THA, and use of the Harris-Galante cup also increased the risk of re-revision of the cup. In separate analyses in which isolated liner revisions were excluded, bone grafting was found to be a risk factor for re-revision of the metal shell due to aseptic loosening (RR = 2.1, CI: 1.05–4.2). Interpretation We found no evidence to support the notion that HA coating improves the performance of the 2 studied cup designs in revision arthroplasty. In contrast, patient-related factors such as younger age and dislocation as the reason for cup revision, and technical factors such as the choice of revision cup were found to influence the risk of subsequent re-revision of the cup. The reason for inferior results after revision of uncemented cups is not known, but it is possible that these hips more often had pronounced bone loss at the index cup revision. PMID:22937978

  14. A 2- to 7-Year Follow-Up of a Modular Iliac Screw Cup in Major Acetabular Defects: Clinical, Radiographic and Survivorship Analysis With Comparison to the Literature.

    PubMed

    Cadossi, Matteo; Garcia, Flávio Luís; Sambri, Andrea; Andreoli, Isabella; Dallari, Dante; Pignatti, Giovanni

    2017-01-01

    Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Outcomes of cup revision for ilio-psoas impingement after total hip arthroplasty: Retrospective study of 46 patients.

    PubMed

    Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S

    2017-12-01

    Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion<10° and/or inclination>50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier Masson SAS.

  16. Development of a novel cup cake with unique properties of essential oil of betel leaf (Piper betle L.) for sustainable entrepreneurship.

    PubMed

    Roy, Arnab; Guha, Proshanta

    2015-08-01

    Betel vine (Piper betle L.) is a root climber with deep green heart shaped leaves. It belongs to the Piperaceae family. There is a huge wastage of the leaves during glut season and it can be reduced by various means including extraction of medicinal essential oil which can be considered as GRAS (generally recognized as safe) materials. Therefore, attempts were made to develop a novel cup cake by incorporating essential oil of betel leaf. The textural properties of the cakes were measured by texture analyzer instrument; whereas the organoleptic properties were adjudged by human preferences using sensory tables containing 9-point hedonic scale. Price estimation was done considering all costs and charges. Finally, all parameters of the developed cake were compared with different cup cakes available in the market for ascertaining consumer acceptability of the newly developed product in terms of quality and market price. Results revealed that the Novel cup cake developed with 0.005 % (v/w) essential oil of betel leaf occupied the 1st place among the four developed novel cup cakes. However, it occupied 4th place among the nine cup cakes in the overall preference list prepared based on the textural and organoleptic qualities, though its market price was calculated to be comparable to all the leading cupcakes available in the market. This indicates that manufacturing of novel cup cake with essential oil of betel leaf would be a profitable and self-sustaining entrepreneurship.

  17. Determination of Process Parameters in Multi-Stage Hydro-Mechanical Deep Drawing by FE Simulation

    NASA Astrophysics Data System (ADS)

    Kumar, D. Ravi; Manohar, M.

    2017-09-01

    In this work, analysis has been carried to simulate manufacturing of a near hemispherical bottom part with large depth by hydro-mechanical deep drawing with an aim to reduce the number of forming steps and to reduce the extent of thinning in the dome region. Inconel 718 has been considered as the material due to its importance in aerospace industry. It is a Ni-based super alloy and it is one of the most widely used of all super alloys primarily due to large-scale applications in aircraft engines. Using Finite Element Method (FEM), numerical simulations have been carried out for multi-stage hydro-mechanical deep drawing by using the same draw ratios and design parameters as in the case of conventional deep drawing in four stages. The results showed that the minimum thickness in the final part can be increased significantly when compared to conventional deep drawing. It has been found that the part could be deep drawn to the desired height (after trimming at the final stage) without any severe wrinkling. Blank holding force (BHF) and peak counter pressure have been found to have a strong influence on thinning in the component. Decreasing the coefficient of friction has marginally increased the minimum thickness in the final component. By increasing the draw ratio and optimizing BHF, counter pressure and die corner radius in the simulations, it has been found that it is possible to draw the final part in three stages. It has been found that thinning can be further reduced by decreasing the initial blank size without any reduction in the final height. This reduced the draw ratio at every stage and optimum combination of BHF and counter pressure have been found for the 3-stage process also.

  18. Effect of Evolutionary Anisotropy on Earing Prediction in Cylindrical Cup Drawing

    NASA Astrophysics Data System (ADS)

    Choi, H. J.; Lee, K. J.; Choi, Y.; Bae, G.; Ahn, D.-C.; Lee, M.-G.

    2017-05-01

    The formability of sheet metals is associated with their planar anisotropy, and finite element simulations have been applied to the sheet metal-forming process by describing the anisotropic behaviors using yield functions and hardening models. In this study, the evaluation of anisotropic constitutive models was performed based on the non-uniform height profile or earing in circular cylindrical cup drawing. Two yield functions, a quadratic Hill1948 and a non-quadratic Yld2000-2d model, were used under non-associated and associated flow rules, respectively, to simultaneously capture directional differences in yield stress and r value. The effect of the evolution of anisotropy on the earing prediction was also investigated by employing simplified equivalent plastic strain rate-dependent anisotropic coefficients. The computational results were in good agreement with experiments when the proper choice of the yield function and flow rule, which predicts the planar anisotropy, was made. Moreover, the accuracy of the earing profile could be significantly enhanced if the evolution of anisotropy between uniaxial and biaxial stress states was additionally considered.

  19. Sunspot drawings handwritten character recognition method based on deep learning

    NASA Astrophysics Data System (ADS)

    Zheng, Sheng; Zeng, Xiangyun; Lin, Ganghua; Zhao, Cui; Feng, Yongli; Tao, Jinping; Zhu, Daoyuan; Xiong, Li

    2016-05-01

    High accuracy scanned sunspot drawings handwritten characters recognition is an issue of critical importance to analyze sunspots movement and store them in the database. This paper presents a robust deep learning method for scanned sunspot drawings handwritten characters recognition. The convolution neural network (CNN) is one algorithm of deep learning which is truly successful in training of multi-layer network structure. CNN is used to train recognition model of handwritten character images which are extracted from the original sunspot drawings. We demonstrate the advantages of the proposed method on sunspot drawings provided by Chinese Academy Yunnan Observatory and obtain the daily full-disc sunspot numbers and sunspot areas from the sunspot drawings. The experimental results show that the proposed method achieves a high recognition accurate rate.

  20. The Use of Match Statistics that Discriminate Between Successful and Unsuccessful Soccer Teams

    PubMed Central

    Castellano, Julen; Casamichana, David; Lago, Carlos

    2012-01-01

    Three soccer World Cups were analysed with the aim of identifying the match statistics which best discriminated between winning, drawing and losing teams. The analysis was based on 177 matches played during the three most recent World Cup tournaments: Korea/Japan 2002 (59), Germany 2006 (59) and South Africa 2010 (59). Two categories of variables were studied: 1) those related to attacking play: goals scored, total shots, shots on target, shots off target, ball possession, number of off-sides committed, fouls received and corners; and 2) those related to defence: total shots received, shots on target received, shots off target received, off-sides received, fouls committed, corners against, yellow cards and red cards. Discriminant analysis of these matches revealed the following: (a) the variables related to attacking play that best differentiated between winning, drawing and losing teams were total shots, shots on target and ball possession; and (b) the most discriminating variables related to defence were total shots received and shots on target received. These results suggest that winning, drawing and losing national teams may be discriminated from one another on the basis of variables such as ball possession and the effectiveness of their attacking play. This information may be of benefit to both coaches and players, adding to their knowledge about soccer performance indicators and helping to guide the training process. PMID:23487020

  1. A Comparative Study on Formability of the Third-Generation Automotive Medium-Mn Steel and 22MnB5 Steel

    NASA Astrophysics Data System (ADS)

    Zheng, Guojun; Li, Xiaodong; Chang, Ying; Wang, Cunyu; Dong, Han

    2018-02-01

    Third-generation advanced automotive medium-Mn steel, which can replace 22MnB5 steel, was newly developed to improve the lightweight and crashworthiness of automobile. Studies on the formability and simulation method of medium-Mn steel have just been initiated. In this study, finite element simulation models of square-cup deep drawing were established based on various material property experiments and validated by experiments. The effects of blank holder force (BHF), fillet radii of tools (die and punch) on the maximum drawing depth (MDD), thickness distribution of the formed products, and the microstructure before and after forming were investigated and compared with those on 22MnB5 steel. Results show that the MDD of the two steels decreased with increased BHF but increased with the fillet radius of punch; however, the fillet radius of die showed no significant effect on the MDD for both steels. Compared with hot-formed 22MnB5 steel, the martensitic transformation of the hot-formed medium-Mn steel is rarely influenced by the process parameters; thus, it holds the complete, fine-grained, and uniform martensitic microstructure. Moreover, the medium-Mn has better formability, lower initial blank temperature, and smaller impact of BHF and fillet radius of tools on the hot-formed product. Thus, a theoretical basis for the replacement of 22MnB5 steel by medium-Mn steel in hot forming process is provided.

  2. The Effect of Chin-cup Therapy in Class III Malocclusion: A Systematic Review

    PubMed Central

    Mousoulea, Sophia; Tsolakis, Ioannis; Ferdianakis, Efstratios; Tsolakis, Apostolos I.

    2016-01-01

    Background: The treatment of Class III malocclusion has been challenging for orthodontists. Among a plethora of treatment modalities, the chin-cup is considered a traditional appliance for early orthopedic intervention. Objective: The present study aims to investigate the current scientific evidence regarding the effectiveness of chin-cup therapy in Class III malocclusion of prognathic growing patients. Method: A systematic review of the literature was conducted using PubMed/Medline and the Cochrane Central Register of Controlled Trials from January 1954 to October 2015. Articles were selected based on established inclusion/ exclusion criteria. Results: The search strategy resulted in 3285 articles.14 studies were selected for the final analysis. They were all CCTs, 13 of retrospective and 1 of prospective design. Methodological quality was evaluated by a risk of bias assessment, as suggested by the Cochrane Risk of Bias Assessment Tool for Non-Randomized Studies on Interventions. The reported evidence presented favorable short-term outcomes both in hard and soft tissues improving the Class III profile, as well as desirable dento-alveolar changes, positively affecting the Class III malocclusion. Conclusion: There is considerable agreement between studies that chin-cup therapy can be considered for the short-term treatment of growing patients with Class III malocclusion, as indicated by favorable changes both in the hard and soft tissues. The existence of considerable risk of bias in all selected studies and the unclear long-term effectiveness of chin-cup therapy highlight the need for further investigation to draw reliable conclusions. PMID:28077971

  3. Sex work and the 2010 FIFA World Cup: time for public health imperatives to prevail

    PubMed Central

    2010-01-01

    Background Sex work is receiving increased attention in southern Africa. In the context of South Africa's intense preparation for hosting the 2010 FIFA World Cup, anxiety over HIV transmission in the context of sex work has sparked debate on the most appropriate legal response to this industry. Discussion Drawing on existing literature, the authors highlight the increased vulnerability of sex workers in the context of the HIV pandemic in southern Africa. They argue that laws that criminalise sex work not only compound sex workers' individual risk for HIV, but also compromise broader public health goals. International sporting events are thought to increase demand for paid sex and, particularly in countries with hyper-endemic HIV such as South Africa, likely to foster increased HIV transmission through unprotected sex. Summary The 2010 FIFA World Cup presents a strategic opportunity for South Africa to respond to the challenges that the sex industry poses in a strategic and rights-based manner. Public health goals and growing evidence on HIV prevention suggest that sex work is best approached in a context where it is decriminalised and where sex workers are empowered. In short, the authors argue for a moratorium on the enforcement of laws that persecute and victimise sex workers during the World Cup period. PMID:20181213

  4. Integrated piezoelectric actuators in deep drawing tools

    NASA Astrophysics Data System (ADS)

    Neugebauer, R.; Mainda, P.; Drossel, W.-G.; Kerschner, M.; Wolf, K.

    2011-04-01

    The production of car body panels are defective in succession of process fluctuations. Thus the produced car body panel can be precise or damaged. To reduce the error rate, an intelligent deep drawing tool was developed at the Fraunhofer Institute for Machine Tools and Forming Technology IWU in cooperation with Audi and Volkswagen. Mechatronic components in a closed-loop control is the main differentiating factor between an intelligent and a conventional deep drawing tool. In correlation with sensors for process monitoring, the intelligent tool consists of piezoelectric actuators to actuate the deep drawing process. By enabling the usage of sensors and actuators at the die, the forming tool transform to a smart structure. The interface between sensors and actuators will be realized with a closed-loop control. The content of this research will present the experimental results with the piezoelectric actuator. For the analysis a production-oriented forming tool with all automotive requirements were used. The disposed actuators are monolithic multilayer actuators of the piezo injector system. In order to achieve required force, the actuators are combined in a cluster. The cluster is redundant and economical. In addition to the detailed assembly structures, this research will highlight intensive analysis with the intelligent deep drawing tool.

  5. Integrated piezoelectric actuators in deep drawing tools to reduce the try-out

    NASA Astrophysics Data System (ADS)

    Neugebauer, Reimund; Mainda, Patrick; Kerschner, Matthias; Drossel, Welf-Guntram; Roscher, Hans-Jürgen

    2011-05-01

    Tool making is a very time consuming and expensive operation because many iteration loops are used to manually adjust tool components during the try-out process. That means that trying out deep drawing tools is 30% of the total costs. This is the reason why an active deep drawing tool was developed at the Fraunhofer Institute for Machine Tools and Forming Technology IWU in cooperation with Audi and Volkswagen to reduce the costs and production rates. The main difference between the active and conventional deep drawing tools is using piezoelectric actuators to control the forming process. The active tool idea, which is the main subject of this research, will be presented as well as the findings of experiments with the custom-built deep drawing tool. This experimental tool was designed according to production requirements and has been equipped with piezoelectric actuators that allow active pressure distribution on the sheet metal flange. The disposed piezoelectric elements are similar to those being used in piezo injector systems for modern diesel engines. In order to achieve the required force, the actuators are combined in a cluster that is embedded in the die of the deep drawing tool. One main objective of this work, i.e. reducing the time-consuming try-out-period, has been achieved with the experimental tool which means that the actuators were used to set static pressure distribution between the blankholder and die. We will present the findings of our analysis and the advantages of the active system over a conventional deep drawing tool. In addition to the ability of changing the static pressure distribution, the piezoelectric actuator can also be used to generate a dynamic pressure distribution during the forming process. As a result the active tool has the potential to expand the forming constraints to make it possible to manage forming restrictions caused by light weight materials in future.

  6. Improved process robustness by using closed loop control in deep drawing applications

    NASA Astrophysics Data System (ADS)

    Barthau, M.; Liewald, M.; Christian, Held

    2017-09-01

    The production of irregular shaped deep-drawing parts with high quality requirements, which are common in today’s automotive production, permanently challenges production processes. High requirements on lightweight construction of passenger car bodies following European regulations until 2020 have been massively increasing the use of high strength steels substantially for years and are also leading to bigger challenges in sheet metal part production. Of course, the more and more complex shapes of today’s car body shells also intensify the issue due to modern and future design criteria. The metal forming technology tries to meet these challenges by developing a highly sophisticated layout of deep drawing dies that consider part quality requirements, process robustness and controlled material flow during the deep or stretch drawing process phase. A new method for controlling material flow using a closed loop system was developed at the IFU Stuttgart. In contrast to previous approaches, this new method allows a control intervention during the deep-drawing stroke. The blank holder force around the outline of the drawn part is used as control variable. The closed loop is designed as trajectory follow up with feed forward control. The used command variable is the part-wall stress that is measured with a piezo-electric measuring pin. In this paper the used control loop will be described in detail. The experimental tool that was built for testing the new control approach is explained here with its features. A method for gaining the follow up trajectories from simulation will also be presented. Furthermore, experimental results considering the robustness of the deep drawing process and the gain in process performance with developed control loop will be shown. Finally, a new procedure for the industrial application of the new control method of deep drawing will be presented by using a new kind of active element to influence the local blank holder pressure onto part flange.

  7. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    PubMed

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Effect of processing parameters on the earing and mechanical properties of strip cast type 3004 Al alloy

    NASA Astrophysics Data System (ADS)

    Es-Said, O. S.; Zeihen, A.; Ruprich, M.; Quattrocchi, J.; Thomas, M.; H. Shin, K.; O'Brien, M.; Johansen, D.; Tijoe, W. H.; Ruhl, D.

    1995-06-01

    Electrical resistivity, superficial hardness, tensile testing, and quantitative metallography techniques were used in this study. The strip cast type 3004 aluminum alloy received sixteen different thermomechanical treatments before cups were drawn. The top edges of the drawn cups were not flat. Rather there were high points or ears with valleys between them. The homogenization temperature varied form 510 to 621 °C at 24 h. Some samples received an additional 426 °C/24 h homogenization anneal. Most specimens were rolled along the longitudinal direction of the as-cast material, and some were rolled in the transverse direction. Most samples were recrystallized at 454 °C for 24 h in addition to the homogenization treatment. Some were recrystallized for 168 h. All samples were subsequently rolled to 0.33 mm for cup drawing and percent earing determination. The percent earing results of some samples were less than 1.5%, but the mechanical strength was also lowered. The high-temperature recrystallization anneal of 454 °C was the controlling factor in determining the earing and mechanical strength of the final rolled sheet.

  9. Effect of processing parameters on the earing and mechanical properties of strip cast type 3004 Al alloy

    NASA Astrophysics Data System (ADS)

    Es-Said, O. S.; Zeihen, A.; Ruprich, M.; Quattrocchi, J.; Thomas, M.; Shin, K. H.; O'Brien, M.; Johansen, D.; Tijoe, W. H.; Ruhl, D.

    1994-02-01

    Electrical resistivity, superficial hardness, tensile testing, and quantitative metallography techniques were used in this study. The strip cast type 3004 aluminum alloy received sixteen different thermomechanical treatments before cups were drawn. The top edges of the drawn cups were not flat. Rather, there were high points or ears with valleys between them. The homogenization temperature varied from 510 to 621 °C at 24 h. Some samples received an additional 426 °C/24 h homogenization anneal. Most specimens were rolled along the longitudinal direction of the as-cast material, and some were rolled in the transverse direction. Most samples were recrystallized at 454 °C for 24 h in addition to the homogenization treatment. Some were recrystallized for 168 h. All samples were subsequently rolled to 0.33 mm for cup drawing and percent earing determination. The percent earing results of some samples were less than 1.5%, but the mechanical strength was also lowered. The high-temperature recrystallization anneal of 454 °C was the controlling factor in determining the earing and mechanical strength of the final rolled sheet.

  10. Futsal World Cup: Differences Created by Winning, Losing and Drawing Variables in Scored Goals and Offensive Variations

    ERIC Educational Resources Information Center

    Balyan, Melih; Vural, Faik

    2018-01-01

    Futsal, which can be defined as a new sports branch compared to football, has some shortcomings in comparison with football as well according to the studies carried out. Studies have rather focused on the movement characteristics of futsal players during the game and the physiological effects of games. On the other hand, there are only a limited…

  11. An advanced constitutive model in the sheet metal forming simulation: the Teodosiu microstructural model and the Cazacu Barlat yield criterion

    NASA Astrophysics Data System (ADS)

    Alves, J. L.; Oliveira, M. C.; Menezes, L. F.

    2004-06-01

    Two constitutive models used to describe the plastic behavior of sheet metals in the numerical simulation of sheet metal forming process are studied: a recently proposed advanced constitutive model based on the Teodosiu microstructural model and the Cazacu Barlat yield criterion is compared with a more classical one, based on the Swift law and the Hill 1948 yield criterion. These constitutive models are implemented into DD3IMP, a finite element home code specifically developed to simulate sheet metal forming processes, which generically is a 3-D elastoplastic finite element code with an updated Lagrangian formulation, following a fully implicit time integration scheme, large elastoplastic strains and rotations. Solid finite elements and parametric surfaces are used to model the blank sheet and tool surfaces, respectively. Some details of the numerical implementation of the constitutive models are given. Finally, the theory is illustrated with the numerical simulation of the deep drawing of a cylindrical cup. The results show that the proposed advanced constitutive model predicts with more exactness the final shape (medium height and ears profile) of the formed part, as one can conclude from the comparison with the experimental results.

  12. Process Simulation of Aluminium Sheet Metal Deep Drawing at Elevated Temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winklhofer, Johannes; Trattnig, Gernot; Lind, Christoph

    Lightweight design is essential for an economic and environmentally friendly vehicle. Aluminium sheet metal is well known for its ability to improve the strength to weight ratio of lightweight structures. One disadvantage of aluminium is that it is less formable than steel. Therefore complex part geometries can only be realized by expensive multi-step production processes. One method for overcoming this disadvantage is deep drawing at elevated temperatures. In this way the formability of aluminium sheet metal can be improved significantly, and the number of necessary production steps can thereby be reduced. This paper introduces deep drawing of aluminium sheet metalmore » at elevated temperatures, a corresponding simulation method, a characteristic process and its optimization. The temperature and strain rate dependent material properties of a 5xxx series alloy and their modelling are discussed. A three dimensional thermomechanically coupled finite element deep drawing simulation model and its validation are presented. Based on the validated simulation model an optimised process strategy regarding formability, time and cost is introduced.« less

  13. Tribology and Tool Wear of Hot Dip Galvanized Zinc Magnesium Alloys on Cold Rolled Steel Sheets

    NASA Astrophysics Data System (ADS)

    Raab, A. E.; Berger, E.; Freudenthaler, J.; Leomann, F.; Walch, C.

    2011-05-01

    Recently zinc based coatings on cold rolled steel with improved functionality in terms of forming and/or corrosion behaviour have been intensively investigated in the steel industry1,2,3. One of the most promising products are zinc magnesium alloys produced in hot dip galvanizing process. These coatings were already introduced in construction industry a few years ago1. With some modifications the improved properties of the coating are also interesting for automotive industry. In the present work the tribological potential of hot dip galvanized zinc magnesium coatings (HDG/ZM) produced at an industrial line under regular production, was studied in terms of sliding properties, adhesive and abrasive tool wear. First a short introduction into surface morphology of HDG/ZM will be given. For the tribological characterization of the material, which is the main topic of the contribution, different tests were performed on hot dip galvanised zinc magnesium material and results were compared with classic hot dip galvanized zinc coating (HDG/Z). The investigations are mainly based on the strip draw test which allows the determination of the friction coefficient directly by using a constant contact pressure. Deep drawing property was tested by forming model cups. The abrasive tool wear was tested using a standard test for material used in automotive industry. The adhesive tool wear was investigated by characterizing the coating material transferred to the tool in the strip draw test. All performed tests show an improved drawability of HDG/ZM compared to classical HDG/Z reference material. However the most promising difference between HDG/ZM and HDG/Z is that galling was found to be less for HDG/ZM than for HDG/Z. Therefore HDG/ZM is an interesting system not only with respect to corrosion protection but also in terms of tribology and provides clear advantages in formability.

  14. Tribology and Tool Wear of Hot Dip Galvanized Zinc Magnesium Alloys on Cold Rolled Steel Sheets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raab, A. E.; Berger, E.; Freudenthaler, J.

    Recently zinc based coatings on cold rolled steel with improved functionality in terms of forming and/or corrosion behaviour have been intensively investigated in the steel industry. One of the most promising products are zinc magnesium alloys produced in hot dip galvanizing process. These coatings were already introduced in construction industry a few years ago. With some modifications the improved properties of the coating are also interesting for automotive industry. In the present work the tribological potential of hot dip galvanized zinc magnesium coatings (HDG/ZM) produced at an industrial line under regular production, was studied in terms of sliding properties, adhesivemore » and abrasive tool wear.First a short introduction into surface morphology of HDG/ZM will be given. For the tribological characterization of the material, which is the main topic of the contribution, different tests were performed on hot dip galvanised zinc magnesium material and results were compared with classic hot dip galvanized zinc coating (HDG/Z). The investigations are mainly based on the strip draw test which allows the determination of the friction coefficient directly by using a constant contact pressure. Deep drawing property was tested by forming model cups. The abrasive tool wear was tested using a standard test for material used in automotive industry. The adhesive tool wear was investigated by characterizing the coating material transferred to the tool in the strip draw test.All performed tests show an improved drawability of HDG/ZM compared to classical HDG/Z reference material. However the most promising difference between HDG/ZM and HDG/Z is that galling was found to be less for HDG/ZM than for HDG/Z. Therefore HDG/ZM is an interesting system not only with respect to corrosion protection but also in terms of tribology and provides clear advantages in formability.« less

  15. Investigation of surface finishing of carbon based coated tools for dry deep drawing of aluminium alloys

    NASA Astrophysics Data System (ADS)

    Steiner, J.; Andreas, K.; Merklein, M.

    2016-11-01

    Global trends like growing environmental awareness and demand for resource efficiency motivate an abandonment of lubricants in metal forming. However, dry forming evokes increased friction and wear. Especially, dry deep drawing of aluminum alloys leads to intensive interaction between tool and workpiece due to its high adhesion tendency. One approach to improve the tribological behavior is the application of carbon based coatings. These coatings are characterized by high wear resistance. In order to investigate the potential of carbon based coatings for dry deep drawing, friction and wear behavior of different coating compositions are evaluated in strip drawing tests. This setup is used to model the tribological conditions in the flange area of deep drawing operations. The tribological behavior of tetrahedral amorphous (ta-C) and hydrogenated amorphous carbon coatings with and without tungsten modification (a-C:H:W, a-C:H) is investigated. The influence of tool topography is analyzed by applying different surface finishing. The results show reduced friction with decreased roughness for coated tools. Besides tool topography the coating type determines the tribological conditions. Smooth tools with ta-C and a-C:H coatings reveal low friction and prevent adhesive wear. In contrast, smooth a-C:H:W coated tools only lead to slight improvement compared to rough, uncoated specimen.

  16. 5. INTERIOR VIEW OF BASEMENT, LOOKING WEST. DEEP DRAW, HEAVY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INTERIOR VIEW OF BASEMENT, LOOKING WEST. DEEP DRAW, HEAVY PRESS MANUFACTURED BY E. W. BLISS CO., BROOKLYN, NEW YORK. PRESS #3-3/4 S, PATENTED BY E. W. BLISS CO., AUGUST 16, 1892, AND JANUARY 31, 1893. THIS PRESS DATES FROM CA. 1920. - Illinois Pure Aluminum Company, 109 Holmes Street, Lemont, Cook County, IL

  17. Retinal fundus images for glaucoma analysis: the RIGA dataset

    NASA Astrophysics Data System (ADS)

    Almazroa, Ahmed; Alodhayb, Sami; Osman, Essameldin; Ramadan, Eslam; Hummadi, Mohammed; Dlaim, Mohammed; Alkatee, Muhannad; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2018-03-01

    Glaucoma neuropathy is a major cause of irreversible blindness worldwide. Current models of chronic care will not be able to close the gap of growing prevalence of glaucoma and challenges for access to healthcare services. Teleophthalmology is being developed to close this gap. In order to develop automated techniques for glaucoma detection which can be used in tele-ophthalmology we have developed a large retinal fundus dataset. A de-identified dataset of retinal fundus images for glaucoma analysis (RIGA) was derived from three sources for a total of 750 images. The optic cup and disc boundaries for each image was marked and annotated manually by six experienced ophthalmologists and included the cup to disc (CDR) estimates. Six parameters were extracted and assessed (the disc area and centroid, cup area and centroid, horizontal and vertical cup to disc ratios) among the ophthalmologists. The inter-observer annotations were compared by calculating the standard deviation (SD) for every image between the six ophthalmologists in order to determine if the outliers amongst the six and was used to filter the corresponding images. The data set will be made available to the research community in order to crowd source other analysis from other research groups in order to develop, validate and implement analysis algorithms appropriate for tele-glaucoma assessment. The RIGA dataset can be freely accessed online through University of Michigan, Deep Blue website (doi:10.7302/Z23R0R29).

  18. Feedback control in deep drawing based on experimental datasets

    NASA Astrophysics Data System (ADS)

    Fischer, P.; Heingärtner, J.; Aichholzer, W.; Hortig, D.; Hora, P.

    2017-09-01

    In large-scale production of deep drawing parts, like in automotive industry, the effects of scattering material properties as well as warming of the tools have a significant impact on the drawing result. In the scope of the work, an approach is presented to minimize the influence of these effects on part quality by optically measuring the draw-in of each part and adjusting the settings of the press to keep the strain distribution, which is represented by the draw-in, inside a certain limit. For the design of the control algorithm, a design of experiments for in-line tests is used to quantify the influence of the blank holder force as well as the force distribution on the draw-in. The results of this experimental dataset are used to model the process behavior. Based on this model, a feedback control loop is designed. Finally, the performance of the control algorithm is validated in the production line.

  19. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter.

    PubMed

    Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A

    2016-04-01

    Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Eggs in the Freezer: Energetic Consequences of Nest Site and Nest Design in Arctic Breeding Shorebirds

    PubMed Central

    Tulp, Ingrid; Schekkerman, Hans; de Leeuw, Joep

    2012-01-01

    Birds construct nests for several reasons. For species that breed in the Arctic, the insulative properties of nests are very important. Incubation is costly there and due to an increasing surface to volume ratio, more so in smaller species. Small species are therefore more likely to place their nests in thermally favourable microhabitats and/or to invest more in nest insulation than large species. To test this hypothesis, we examined characteristics of nests of six Arctic breeding shorebird species. All species chose thermally favourable nesting sites in a higher proportion than expected on the basis of habitat availability. Site choice did not differ between species. Depth to frozen ground, measured near the nests, decreased in the course of the season at similar non-species-specific speeds, but this depth increased with species size. Nest cup depth and nest scrape depth (nest cup without the lining) were unrelated to body mass (we applied an exponent of 0.73, to account for metabolic activity of the differently sized species). Cup depth divided by diameter2 was used as a measure of nest cup shape. Small species had narrow and deep nests, while large species had wide shallow nests. The thickness of nest lining varied between 0.1 cm and 7.6 cm, and decreased significantly with body mass. We reconstruct the combined effect of different nest properties on the egg cooling coefficient using previously published quantitative relationships. The predicted effect of nest cup depth and lining depth on heat loss to the frozen ground did not correlate with body mass, but the sheltering effect of nest cup diameter against wind and the effects of lining material on the cooling coefficient increased with body mass. Our results suggest that small arctic shorebirds invest more in the insulation of their nests than large species. PMID:22701596

  1. Risk of symptomatic dengue for foreign visitors to the 2014 FIFA World Cup in Brazil

    PubMed Central

    Massad, Eduardo; Wilder-Smith, Annelies; Ximenes, Raphael; Amaku, Marcos; Lopez, Luis Fernandez; Coutinho, Francisco Antonio Bezerra; Coelho, Giovanini Evelim; da Silva, Jarbas Barbosa; Struchiner, Claudio José; Burattini, Marcelo Nascimento

    2014-01-01

    Brazil will host the FIFA World Cup™, the biggest single-event competition in the world, from June 12-July 13 2014 in 12 cities. This event will draw an estimated 600,000 international visitors. Brazil is endemic for dengue. Hence, attendees of the 2014 event are theoretically at risk for dengue. We calculated the risk of dengue acquisition to non-immune international travellers to Brazil, depending on the football match schedules, considering locations and dates of such matches for June and July 2014. We estimated the average per-capita risk and expected number of dengue cases for each host-city and each game schedule chosen based on reported dengue cases to the Brazilian Ministry of Health for the period between 2010-2013. On the average, the expected number of cases among the 600,000 foreigner tourists during the World Cup is 33, varying from 3-59. Such risk estimates will not only benefit individual travellers for adequate pre-travel preparations, but also provide valuable information for public health professionals and policy makers worldwide. Furthermore, estimates of dengue cases in international travellers during the World Cup can help to anticipate the theoretical risk for exportation of dengue into currently non-infected areas. PMID:24863976

  2. Risk of symptomatic dengue for foreign visitors to the 2014 FIFA World Cup in Brazil.

    PubMed

    Massad, Eduardo; Wilder-Smith, Annelies; Ximenes, Raphael; Amaku, Marcos; Lopez, Luis Fernandez; Coutinho, Francisco Antonio Bezerra; Coelho, Giovanini Evelim; Silva, Jarbas Barbosa da; Struchiner, Claudio José; Burattini, Marcelo Nascimento

    2014-06-01

    Brazil will host the FIFA World Cup™, the biggest single-event competition in the world, from June 12-July 13 2014 in 12 cities. This event will draw an estimated 600,000 international visitors. Brazil is endemic for dengue. Hence, attendees of the 2014 event are theoretically at risk for dengue. We calculated the risk of dengue acquisition to non-immune international travellers to Brazil, depending on the football match schedules, considering locations and dates of such matches for June and July 2014. We estimated the average per-capita risk and expected number of dengue cases for each host-city and each game schedule chosen based on reported dengue cases to the Brazilian Ministry of Health for the period between 2010-2013. On the average, the expected number of cases among the 600,000 foreigner tourists during the World Cup is 33, varying from 3-59. Such risk estimates will not only benefit individual travellers for adequate pre-travel preparations, but also provide valuable information for public health professionals and policy makers worldwide. Furthermore, estimates of dengue cases in international travellers during the World Cup can help to anticipate the theoretical risk for exportation of dengue into currently non-infected areas.

  3. Formability of paperboard during deep-drawing with local steam application

    NASA Astrophysics Data System (ADS)

    Franke, Wilken; Stein, Philipp; Dörsam, Sven; Groche, Peter

    2018-05-01

    The use of paperboard can significantly improve the environmental compatibility of everyday products such as packages. Nevertheless, most packages are currently made of plastics, since the three-dimensional shaping of paperboard is possible only to a limited extent. In order to increase the forming possibilities, deep drawing of cardboard has been intensively investigated for more than a decade. An improvement with regard to increased forming limits has been achieved by heating of the tool parts, which leads to a softening of paperboard constituents such as lignin. A further approach is the moistening of the samples, whereby the hydrogen bonds between the fibers are weakened and as a result an increase of the formability. It is expected that a combination of both parameter approaches will result in a significant increase in the forming capacity and in the shape accuracy. For this reason, a new tool concept is introduced within the scope of this work which makes it possible to moisten samples during the deep drawing process by means of steam supply. The conducted investigations show that spring-back in the preferred fiber direction can be reduced by 38 %. Orthogonal to the preferred fiber direction a reduction of spring back of up to 79 % is determined, which corresponds to a perfect shape. Moreover, it was determined that the steam duration and the initial moisture content have an influence on the final shape. In addition to the increased dimensional accuracy, an optimized wrinkle compression compared to conventional deep drawing is found. According to the results, it can be summarized that a steam application in the deep drawing of paperboard significantly improves the part quality.

  4. Numerical-experimental investigation of load paths in DP800 dual phase steel during Nakajima test

    NASA Astrophysics Data System (ADS)

    Bergs, Thomas; Nick, Matthias; Feuerhack, Andreas; Trauth, Daniel; Klocke, Fritz

    2018-05-01

    Fuel efficiency requirements demand lightweight construction of vehicle body parts. The usage of advanced high strength steels permits a reduction of sheet thickness while still maintaining the overall strength required for crash safety. However, damage, internal defects (voids, inclusions, micro fractures), microstructural defects (varying grain size distribution, precipitates on grain boundaries, anisotropy) and surface defects (micro fractures, grooves) act as a concentration point for stress and consequently as an initiation point for failure both during deep drawing and in service. Considering damage evolution in the design of car body deep drawing processes allows for a further reduction in material usage and therefore body weight. Preliminary research has shown that a modification of load paths in forming processes can help mitigate the effects of damage on the material. This paper investigates the load paths in Nakajima tests of a DP800 dual phase steel to research damage in deep drawing processes. Investigation is done via a finite element model using experimentally validated material data for a DP800 dual phase steel. Numerical simulation allows for the investigation of load paths with respect to stress states, strain rates and temperature evolution, which cannot be easily observed in physical experiments. Stress triaxiality and the Lode parameter are used to describe the stress states. Their evolution during the Nakajima tests serves as an indicator for damage evolution. The large variety of sheet metal forming specific load paths in Nakajima tests allows a comprehensive evaluation of damage for deep drawing. The results of the numerical simulation conducted in this project and further physical experiments will later be used to calibrate a damage model for simulation of deep drawing processes.

  5. Shear Fracture of Dual Phase AHSS in the Process of Stamping: Macroscopic Failure Mode and Micro-level Metallographical Observation

    NASA Astrophysics Data System (ADS)

    Wang, Wurong; Wei, Xicheng; Yang, Jun; Shi, Gang

    2011-08-01

    Due to its excellent strength and formability combinations, dual phase (DP) steels offer the potential to improve the vehicle crashworthiness performance without increasing car body weight and have been increasingly used into new vehicles. However, a new type of crack mode termed as shear fracture is accompanied with the application of these high strength DP steel sheets. With the cup drawing experiment to identify the limit drawing ratio (LDR) of three DP AHSS with strength level from 600 MPa to 1000 MPa, the study compared and categorized the macroscopic failure mode of these three types of materials. The metallographical observation along the direction of crack was conducted for the DP steels to discover the micro-level propagation mechanism of the fracture.

  6. Cupping Therapy May be Harmful for Eczema: A PubMed Search

    PubMed Central

    Hon, Kam Lun E.; Luk, David Chi Kong; Leong, Kin Fon; Leung, Alexander K. C.

    2013-01-01

    Eczema is a common childhood atopic condition and treatment is with emollients, topical corticosteroids, and avoidance of possible triggers. S. aureus colonization is a common complication. As there is no immediate cure, many parents seek alternative therapies that claim unproven therapeutic efficacy. We report a girl with long history of treatment noncompliance. After practicing a long period of dietary avoidance and supplementation, the grandparents took her to an alternative medicine practitioner. Following cupping therapy and acupuncture, the child developed blistering and oozing over her back the next day, which rapidly evolved to two large irregular-edge deep ulcers. She was treated with intravenous antibiotics and received multidisciplinary supportive intervention. Using search words of  “cupping,” “eczema,” and “atopic dermatitis,” only two reports were found on PubMed. Therapeutic efficacy was claimed but not scientifically documented in these reports. Childhood eczema is an eminently treatable atopic disease. Extreme alternative therapy seems not to be efficacious and may even be associated with serious undesirable sequelae. Physicians should be aware of various alternative treatment modalities and be prepared to offer evidence-based advice to the patients with eczema and their families. PMID:24282650

  7. Afterrise: Deep Body Temperature Following Exercise

    DTIC Science & Technology

    1992-03-01

    Egalement, les effets de la posture et des v~tements durant la recuperation et la temperature de la salle de recuperation furent examines. Cinq hommes se...chemise a manches courtes). Les temperatures rectales et de la peau furent mesurees A chaque minute durant les exercices et la r~cup~ration affectaient...overgarment. RESUME Cette etude fut entreprise pour documenter l’augmentation continue de la temperature rectale apres exercice dans la chaleur

  8. Effects of hypnosis and level of processing on repeated recall of line drawings.

    PubMed

    McKelvie, S J; Pullara, M

    1988-07-01

    Moderately susceptible subjects (N = 30) initially judged 30 line drawings of objects for pleasantness (deep processing) and 30 line drawings for visual complexity (shallow processing), after which they were given two immediate recall tests. Following a 48-hr delay, subjects were allocated randomly to hypnosis, simulation, or neutral control conditions and were tested four more times. Subjects produced more correct and incorrect responses over the six trials and gave a higher number of correct responses for deep items than for shallow items. Over the last four trials, hypnosis had no general facilitative effect relative to the other two treatments, but the effect of depth was strongest for hypnotized subjects, who recalled more deep items than did the controls. Finally, both hypnotized and simulating subjects rated their recall as more involuntary and their experimental treatment as more helpful than did the controls. Caution is urged in the forensic use of hypnosis as a retrieval device.

  9. The drawing effect: Evidence for reliable and robust memory benefits in free recall.

    PubMed

    Wammes, Jeffrey D; Meade, Melissa E; Fernandes, Myra A

    2016-01-01

    In 7 free-recall experiments, the benefit of creating drawings of to-be-remembered information relative to writing was examined as a mnemonic strategy. In Experiments 1 and 2, participants were presented with a list of words and were asked to either draw or write out each. Drawn words were better recalled than written. Experiments 3-5 showed that the memory boost provided by drawing could not be explained by elaborative encoding (deep level of processing, LoP), visual imagery, or picture superiority, respectively. In Experiment 6, we explored potential limitations of the drawing effect, by reducing encoding time and increasing list length. Drawing, relative to writing, still benefited memory despite these constraints. In Experiment 7, the drawing effect was significant even when encoding trial types were compared in pure lists between participants, inconsistent with a distinctiveness account. Together these experiments indicate that drawing enhances memory relative to writing, across settings, instructions, and alternate encoding strategies, both within- and between-participants, and that a deep LoP, visual imagery, or picture superiority, alone or collectively, are not sufficient to explain the observed effect. We propose that drawing improves memory by encouraging a seamless integration of semantic, visual, and motor aspects of a memory trace.

  10. Experimental and Numerical Studies on Fiber Deformation and Formability in Thermoforming Process Using a Fast-Cure Carbon Prepreg: Effect of Stacking Sequence and Mold Geometry.

    PubMed

    Bae, Daeryeong; Kim, Shino; Lee, Wonoh; Yi, Jin Woo; Um, Moon Kwang; Seong, Dong Gi

    2018-05-21

    A fast-cure carbon fiber/epoxy prepreg was thermoformed against a replicated automotive roof panel mold (square-cup) to investigate the effect of the stacking sequence of prepreg layers with unidirectional and plane woven fabrics and mold geometry with different drawing angles and depths on the fiber deformation and formability of the prepreg. The optimum forming condition was determined via analysis of the material properties of epoxy resin. The non-linear mechanical properties of prepreg at the deformation modes of inter- and intra-ply shear, tensile and bending were measured to be used as input data for the commercial virtual forming simulation software. The prepreg with a stacking sequence containing the plain-woven carbon prepreg on the outer layer of the laminate was successfully thermoformed against a mold with a depth of 20 mm and a tilting angle of 110°. Experimental results for the shear deformations at each corner of the thermoformed square-cup product were compared with the simulation and a similarity in the overall tendency of the shear angle in the path at each corner was observed. The results are expected to contribute to the optimization of parameters on materials, mold design and processing in the thermoforming mass-production process for manufacturing high quality automotive parts with a square-cup geometry.

  11. Experimental and Numerical Studies on Fiber Deformation and Formability in Thermoforming Process Using a Fast-Cure Carbon Prepreg: Effect of Stacking Sequence and Mold Geometry

    PubMed Central

    Bae, Daeryeong; Kim, Shino; Lee, Wonoh; Yi, Jin Woo; Um, Moon Kwang; Seong, Dong Gi

    2018-01-01

    A fast-cure carbon fiber/epoxy prepreg was thermoformed against a replicated automotive roof panel mold (square-cup) to investigate the effect of the stacking sequence of prepreg layers with unidirectional and plane woven fabrics and mold geometry with different drawing angles and depths on the fiber deformation and formability of the prepreg. The optimum forming condition was determined via analysis of the material properties of epoxy resin. The non-linear mechanical properties of prepreg at the deformation modes of inter- and intra-ply shear, tensile and bending were measured to be used as input data for the commercial virtual forming simulation software. The prepreg with a stacking sequence containing the plain-woven carbon prepreg on the outer layer of the laminate was successfully thermoformed against a mold with a depth of 20 mm and a tilting angle of 110°. Experimental results for the shear deformations at each corner of the thermoformed square-cup product were compared with the simulation and a similarity in the overall tendency of the shear angle in the path at each corner was observed. The results are expected to contribute to the optimization of parameters on materials, mold design and processing in the thermoforming mass-production process for manufacturing high quality automotive parts with a square-cup geometry. PMID:29883413

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebenga, J. H.; Atzema, E. H.; Boogaard, A. H. van den

    Robust design of forming processes using numerical simulations is gaining attention throughout the industry. In this work, it is demonstrated how robust optimization can assist in further stretching the limits of metal forming processes. A deterministic and a robust optimization study are performed, considering a stretch-drawing process of a hemispherical cup product. For the robust optimization study, both the effect of material and process scatter are taken into account. For quantifying the material scatter, samples of 41 coils of a drawing quality forming steel have been collected. The stochastic material behavior is obtained by a hybrid approach, combining mechanical testingmore » and texture analysis, and efficiently implemented in a metamodel based optimization strategy. The deterministic and robust optimization results are subsequently presented and compared, demonstrating an increased process robustness and decreased number of product rejects by application of the robust optimization approach.« less

  13. Impact of redox and transport processes in a riparian wetland on stream water quality in the Fichtelgebirge region, southern Germany

    NASA Astrophysics Data System (ADS)

    Lischeid, G.; Kolb, A.; Alewell, C.; Paul, S.

    2007-01-01

    Biologically mediated redox processes in the riparian zone, like denitrification, can have substantially beneficial impacts on stream water quality. The extent of these effects, however, depends greatly on the hydrological boundary conditions. The impact of hydrological processes on a wetland's nitrogen sink capacity was investigated in a forested riparian fen which is drained by a first-order perennial stream. Here, we analysed the frequency distributions and time-series of pH and nitrogen, silica, organic carbon and oxygen concentrations in throughfall, soil solution, groundwater and stream water, and the groundwater levels and stream discharges from a 3-year period. During baseflow conditions, the stream was fed by discharging shallow, anoxic groundwater and by deep, oxic groundwater. Whereas the latter delivered considerable amounts of nitrogen (0.37 mg l-1) to the stream, the former was almost entirely depleted of nitrogen. During stormflow, near-surface runoff in the upper 30 cm soil layer bypassed the denitrifying zone and added significant amounts to the nitrogen load of the stream. Nitrate-nitrogen was close to 100% of deep groundwater and stream-water nitrogen concentration. Stream-water baseflow concentrations of nitrate, dissolved carbon and silica were about 1.6 mg l-1, 4 mg l-1 and 7.5 mg l-1 respectively, and >3 mg l-1, >10 mg l-1 and <4 mg l-1 respectively during discharge peaks. In addition to that macroscale bypassing effect, there was evidence for a corresponding microscale effect: Shallow groundwater sampled by soil suction cups indicated complete denitrification and lacked any seasonal signal of solute concentration, which was in contrast to piezometer samples from the same depth. Moreover, mean solute concentration in the piezometer samples resembled more that of suction-cup samples from shallower depth than that of the same depth. We conclude that the soil solution cups sampled to a large extent the immobile soil-water fraction. In contrast, the mobile fraction that was sampled by the piezometers exhibited substantially shorter residence time, thus being less exposed to denitrification, but predominating discharge of that layer to the stream. Consequently, assessing the nitrogen budget based on suction-cup data tended to overestimate the nitrogen consumption in the riparian wetland. These effects are likely to become more important with the increased frequency and intensity of rainstorms that are expected due to climate change. Copyright

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, H; Gao, Y; Liu, T

    Purpose: To develop quantitative clinical guidelines between supine Deep Inspiratory Breath Hold (DIBH) and prone free breathing treatments for breast patients, we applied 3D deformable phantoms to perform Monte Carlo simulation to predict corresponding Dose to the Organs at Risk (OARs). Methods: The RPI-adult female phantom (two selected cup sizes: A and D) was used to represent the female patient, and it was simulated using the MCNP6 Monte Carlo code. Doses to OARs were investigated for supine DIBH and prone treatments, considering two breast sizes. The fluence maps of the 6-MV opposed tangential fields were exported. In the Monte Carlomore » simulation, the fluence maps allow each simulated photon particle to be weighed in the final dose calculation. The relative error of all dose calculations was kept below 5% by simulating 3*10{sup 7} photons for each projection. Results: In terms of dosimetric accuracy, the RPI Adult Female phantom with cup size D in DIBH positioning matched with a DIBH treatment plan of the patient. Based on the simulation results, for cup size D phantom, prone positioning reduced the cardiac dose and the dose to other OARs, while cup size A phantom benefits more from DIBH positioning. Comparing simulation results for cup size A and D phantom, dose to OARs was generally higher for the large breast size due to increased scattering arising from a larger portion of the body in the primary beam. The lower dose that was registered for the heart in the large breast phantom in prone positioning was due to the increase of the distance between the heart and the primary beam when the breast was pendulous. Conclusion: Our 3D deformable phantom appears an excellent tool to predict dose to the OARs for the supine DIBH and prone positions, which might help quantitative clinical decisions. Further investigation will be conducted. National Institutes of Health R01EB015478.« less

  15. The Underground Laboratory in South Korea : facilities and experiments

    NASA Astrophysics Data System (ADS)

    Kim, Yeongduk

    2017-01-01

    We have developed underground physics programs for last 15 years in South Korea. The scientific and technical motivation for this initiative was the lack of local facility of a large accelerator in Korea. Thanks to the large underground electric power generator in Yangyang area, we could construct a deep underground laboratory (Yangyang Laboratory, Y2L) and has performed some pioneering experiments for dark matter search and double beta decay experiments. Since year of 2013, a new research center in the Institute for Basic Science (IBS), Center for Underground Physics (CUP), is approved by the government and Y2L laboratory is managed by CUP. Due to the limited space in Y2L, we are proposing to construct a new deep underground laboratory where we can host larger scale experiments of next generation. The site is in an active iron mine, and will be made in 1100 meter underground with a space of about 2000 m2 by the end of 2019. I will describe the status and future plan for this underground laboratory. CUP has two main experimental programs. (1) Identification of dark matter : The annual modulation signal of DAMA/LIBRA experiment has been contradictory to many other experiments such as XENON100, LUX, and Super CDMS. Yale University and CUP (COSINE-100) experimentalists agreed to do an experiment together at the Y2L and recently commissioned a 100kg scale low background NaI(Tl) crystal experiment. In future, we will develop NaI(Tl) crystals with lower internal backgrounds and try to run identical detectors at both north and south hemisphere. Low mass WIMP search is also planned with a development of low temperature sensors coupled with highly scintillating crystals. (2) Neutrinoless double beta decay search : The mass of the lightest neutrino and the Majorana nature of the neutrinos are not determined yet. Neutrinoless double beta decay experiment can answer both of the questions directly, and ultra-low backgrounds and excellent energy resolution are critical to discover this ultra rare phenomena. AMoRE (Advanced Mo-based Rare phenomena Experiment) is a state-of-art experiment based on low temperature MMC sensor and ultra pure molybdate crystals containing highly enriched isotopes. With 200 kg of molybdate crystals running 3 years, It's sensitivity goal is reaching 1027 years of half-life and down to 15-30 meV neutrino mass. AMoRE-pilot experiment with 1.5 kg of enriched Mo-100 crystals is running at Y2L now. In addition to the two main physics program, CUP is doing NEOS short baseline neutrino experiment and also develops new experiments for new parameter search for dark photons, WIMPs, and double beta decay experiments.

  16. Prediction of forming limit in hydro-mechanical deep drawing of steel sheets using ductile fracture criterion

    NASA Astrophysics Data System (ADS)

    Oh, S.-T.; Chang, H.-J.; Oh, K. H.; Han, H. N.

    2006-04-01

    It has been observed that the forming limit curve at fracture (FLCF) of steel sheets, with a relatively higher ductility limit have linear shapes, similar to those of a bulk forming process. In contrast, the FLCF of sheets with a relatively lower ductility limit have rather complex shapes approaching the forming limit curve at neck (FLCN) towards the equi-biaxial strain paths. In this study, the FLCFs of steel sheets were measured and compared with the fracture strains predicted from specific ductile fracture criteria, including a criterion suggested by the authors, which can accurately describe FLCFs with both linear and complex shapes. To predict the forming limit for hydro-mechanical deep drawing of steel sheets, the ductile fracture criteria were integrated into a finite element simulation. The simulation, results based on the criterion suggested by authors accurately predicted the experimetal, fracture limits of steel sheets for the hydro-mechanical deep drawing process.

  17. Forming Limit Diagram of Titanium and Stainless Steel Alloys to Study the Formability of Hydro-Mechanical Deep Drawing Parts

    NASA Astrophysics Data System (ADS)

    Shirizly, A.

    2005-08-01

    The increase demand for stronger, lighter and economic sheet metal products, make the Hydromecanical deep drawing process lately more and more popular. The Hydromecanical process is used in almost all types of sheet metal parts from home appliances and kitchenware to automotive and aviation industries. Therefore, many common materials were tested and characterized by their ability to sustain large strains via the well known Forming Limit Diagram (FLD). The aim of this work is to examine the forming capability if the Hydromecanical process in production of hemisphere parts made of materials commonly used in the aviation and aerospace industries. Experimental procedures were carried out to assess their ductility through FLD and the Forming Limit Carve (FLC).Two type of material sheets were tested herewith for demonstrating the procedure: commercial pure titanium and stainless steel 316L. A numerical simulation of the Hydromecanical process was examined and compared to self made Hydromecanical deep drawing of hemispherical parts.

  18. Postural stability, clicker reaction time and bow draw force predict performance in elite recurve archery.

    PubMed

    Spratford, Wayne; Campbell, Rhiannon

    2017-06-01

    Recurve archery is an Olympic sport that requires extreme precision, upper body strength and endurance. The purpose of this research was to quantify how postural stability variables both pre- and post-arrow release, draw force, flight time, arrow length and clicker reaction time, collectively, impacted on the performance or scoring outcomes in elite recurve archery athletes. Thirty-nine elite-level recurve archers (23 male and 16 female; mean age = 24.7 ± 7.3 years) from four different countries volunteered to participate in this study prior to competing at a World Cup event. An AMTI force platform (1000Hz) was used to obtain centre of pressure (COP) measurements 1s prior to arrow release and 0.5s post-arrow release. High-speed footage (200Hz) allowed for calculation of arrow flight time and score. Results identified clicker reaction time, draw force and maximum sway speed as the variables that best predicted shot performance. Specifically, reduced clicker reaction time, greater bow draw force and reduced postural sway speed post-arrow release were predictors of higher scoring shots. It is suggested that future research should focus on investigating shoulder muscle tremors at full draw in relation to clicker reaction time, and the effect of upper body strength interventions (specifically targeting the musculature around the shoulder girdle) on performance in recurve archers.

  19. [Clinical observation on common peroneal nerve palsy treated with comprehensive therapy].

    PubMed

    Yang, Li-Juan; Liu, Ya-Li; Wang, Shu-Bin; Jin, Zhi-Gao

    2014-04-01

    To compare the difference of the clinical efficacy on common peroneal palsy between the comprehensive therapy of electroacupuncture, moxibustion and moving cupping method and western medication. Ninety cases of common peroneal nerve palsy were randomized into a comprehensive therapy group and a western medication group, 45 cases in each one. In the comprehensive therapy group, electroacupuncture was applied to Yanglingquan (GB 34), Zusanli (ST 36), Xuanzhong (GB 39), Jiexi (ST 41), Taichong (LR 3), Zulinqi (GB 41) and the others, combined with warm moxibustion and moving cupping on the lateral side of the affected leg. The comprehensive therapy was used once a day. In the western medication group, vitamin B1 , 10 mg each time, 3 times a day; and mecobalamine, 0. 5 mg each time, three times a day were prescribed for oral administration. In the two groups, 15 days made one session, and the efficacy was observed after 2 sessions treatment. The total effective rate of the improvement of sensory function and motor nerve function was 97. 8% (44/45) in the comprehensive therapy group and was 82. 2% (37/ 45) in the western medication. The efficacy in the comprehensive therapy group was better than that of the western medication (P<0. 01). The electrophysiological examination showed that the amplitude of motor conduction of deep peroneal nerve and that of sensory conduction of surficial peroneal nerve after treatment were improved remarkably as compared with those before treatment in the comprehensive therapy group (both P<0. 05). The amplitude of motor conduction of deep peroneal nerve was improved significantly in the comprehensive therapy group as compared with that in the western medication group (P<0. 05). The comprehensive therapy of electroacupuncture, moxibustion and moving cupping method achieves the significant efficacy on common peroneal nerve palsy as compared with western medication.

  20. Earing Prediction in Cup Drawing using the BBC2008 Yield Criterion

    NASA Astrophysics Data System (ADS)

    Vrh, Marko; Halilovič, Miroslav; Starman, Bojan; Štok, Boris; Comsa, Dan-Sorin; Banabic, Dorel

    2011-08-01

    The paper deals with constitutive modelling of highly anisotropic sheet metals. It presents FEM based earing predictions in cup drawing simulation of highly anisotropic aluminium alloys where more than four ears occur. For that purpose the BBC2008 yield criterion, which is a plane-stress yield criterion formulated in the form of a finite series, is used. Thus defined criterion can be expanded to retain more or less terms, depending on the amount of given experimental data. In order to use the model in sheet metal forming simulations we have implemented it in a general purpose finite element code ABAQUS/Explicit via VUMAT subroutine, considering alternatively eight or sixteen parameters (8p and 16p version). For the integration of the constitutive model the explicit NICE (Next Increment Corrects Error) integration scheme has been used. Due to the scheme effectiveness the CPU time consumption for a simulation is comparable to the time consumption of built-in constitutive models. Two aluminium alloys, namely AA5042-H2 and AA2090-T3, have been used for a validation of the model. For both alloys the parameters of the BBC2008 model have been identified with a developed numerical procedure, based on a minimization of the developed cost function. For both materials, the predictions of the BBC2008 model prove to be in very good agreement with the experimental results. The flexibility and the accuracy of the model together with the identification and integration procedure guarantee the applicability of the BBC2008 yield criterion in industrial applications.

  1. Underground laboratories in Asia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Shin Ted, E-mail: linst@mails.phys.sinica.edu.tw; Yue, Qian, E-mail: yueq@mail.tsinghua.edu.cn

    2015-08-17

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed.

  2. Underground laboratories in Asia

    NASA Astrophysics Data System (ADS)

    Lin, Shin Ted; Yue, Qian

    2015-08-01

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed.

  3. Steel Foil Improves Performance Of Blasting Caps

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J.; Perry, Ronnie; Schimmel, Morry L.

    1990-01-01

    Blasting caps, which commonly include deep-drawn aluminum cups, give significantly higher initiation performance by application of steel foils on output faces. Steel closures 0.005 in. (0.13 mm) thick more effective than aluminum. Caps with directly bonded steel foil produce fragment velocities of 9,300 ft/s (2.8 km/s) with large craters and unpredictable patterns to such degree that no attempts made to initiate explosions. Useful in military and aerospace applications and in specialized industries as mining and exploration for oil.

  4. Electro-thermo-mechanical coupling analysis of deep drawing with resistance heating for aluminum matrix composites sheet

    NASA Astrophysics Data System (ADS)

    Zhang, Kaifeng; Zhang, Tuoda; Wang, Bo

    2013-05-01

    Recently, electro-plastic forming to be a focus of attention in materials hot processing research area, because it is a sort of energy-saving, high efficient and green manufacturing technology. An electro-thermo-mechanical model can be adopted to carry out the sequence simulation of aluminum matrix composites sheet deep drawing via electro-thermal coupling and thermal-mechanical coupling method. The first step of process is resistance heating of sheet, then turn off the power, and the second step is deep drawing. Temperature distribution of SiCp/2024Al composite sheet by resistance heating and sheet deep drawing deformation were analyzed. During the simulation, effect of contact resistances, temperature coefficient of resistance for electrode material and SiCp/2024Al composite on temperature distribution were integrally considered. The simulation results demonstrate that Sicp/2024Al composite sheet can be rapidly heated to 400° in 30s using resistances heating and the sheet temperature can be controlled by adjusting the current density. Physical properties of the electrode materials can significantly affect the composite sheet temperature distribution. The temperature difference between the center and the side of the sheet is proportional to the thermal conductivity of the electrode, the principal cause of which is that the heat transfers from the sheet to the electrode. SiCp/2024Al thin-wall part can be intactly manufactured at strain rate of 0.08s-1 and the sheet thickness thinning rate is limited within 20%, which corresponds well to the experimental result.

  5. [Innovation of characteristic medicinal cupping devices].

    PubMed

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both P<0. 05). The comfort with the innovated medicinal cupping device was remarkably improved as compared with the traditional one at the two acupoints (both P<0. 05). The medicinal leakage was similar between the two different devices during the cupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  6. [Clinical value of cupping spot effect].

    PubMed

    Ji, Chang-Chun; Huang, Li-Ping; Yang, Gai-Qin; Zhao, Jing-Yu; Zou, Wei; Guo, Xiao-Chuan; Liu, Shao-Ming

    2014-12-01

    The cupping spot is considered as one kind of skin change due to cupping treatment. With literature regarding cupping spot, the influencing factors and value of cupping spot in clinical diagnosis and treatment were analyzed, which could make a further exploration on the action mechanism of cupping treatment. The literature showed that the formation of cupping spot was related with cupping temperature, pressure, cup-retaining time, cupping area, individual difference and health condition, etc; cupping spot had the ability to assist diagnosis, prevent disease, cure disease and evaluate clinical efficacy. Previous studies on cupping spot have already made some progress, and played a positive significance on finding cupping rule and studying its mechanism. However, the research for this area is still in the primary stage, which needed deeper study to reveal scientific connotations of cupping spot.

  7. [Mid-Term to Long-Term Results of Revision Total Hip Arthroplasty Using the Oval-Shaped Acetabular Cup - TC Type].

    PubMed

    Šťastný, E; Trč, T; Frýdl, J; Kopečný, Z; Philippou, T; Lisý, J

    2017-01-01

    INTRODUCTION The purpose of our paper is to evaluate the mid-term to long-term results and to confirm the basic criteria of a high-quality revision implant: safe bridging of bone defects, achievement of reliable primary fixation of revision acetabular cup, achievement of good secondary stability with documentable osteointegration of cup and demonstration of remodelling of transplanted bone tissue in the area of defects and in spaces between the implant ribs. MATERIAL AND METHODS Altogether 36 patients (38 cups) were evaluated who had undergone revision hip arthroplasty in the period from 2004 to 2010. The mean follow-up was 8.2 years (5.1-11.6 years after the reimplantation, more than 10 years in 16 patients who underwent surgery). The position and osseointegration of the implant were assessed by digital radiography, the remodelling of transplanted bone tissues in the area of defects and between the implant ribs by computed tomography with reducing artefacts around the metal implant (Aquilion 64 - Toshiba Medical Systems), and for the clinical outcomes the Harris Hip Score was used. RESULTS Preoperatively, the condition of the hip joint based on the Harris Hip Score was in 30 cases evaluated as poor, in 8 patients as satisfactory. At the time of final evaluation, 8 patients achieved excellent results, in 19 patients the condition of the joint was very good (in 2 patients bilaterally), in 6 patients it was considered satisfactory and in 3 patients poor. The mean value for HHS increased from 39.5 to 84.5. Based on the radiography evaluation, in 27 patients (in 2 patients bilaterally) the osseointegration of the revision cup was good, in 8 cases with a radiolucent line of 2-4 mm in width in DeLee zone III, in one case proximal migration of the cup occurred caused by deep infection. The informed consent form for pelvic CT was signed by 25 patients of our cohort. Remodelling of bone tissue in the space between the ribs of the implant was always detected, the presence of bone cysts was not reported, the bone defects following the application of autologous spongioplasty in the monitored patients were healed. In 6 patients, an ingrowth of fibrous tissue of 2-4 mm in width in the convexity of the cup was detected. The mean survival of the revision oval-shaped cup - TC type with a follow-up of 8.2 years after the reimplantation based on Kaplan-Meier analysis was 91.4 %. DISCUSSION The number of revision total hip arthroplasties due to a younger age of patients who undergo alloplasty keeps growing. The choice of a revision implant should always match the intraoperative finding and the bone tissue quality. The standard uncemented implants with osteoactive surface can be opted for when anterior and posterior column of the acetabulum are intact (IIA and IIB according to Paprosky). Starting from type IIC, also the proximal part of acetabulum shall be considered. At our department, preference is given to the revision cup - TC type. The oval shape facilitates a lower degree of bone resection and easier restoration of the anatomical centre of rotation. Careful debridement of granulating and necrotic tissue, thorough treatment of bone defects and osteoactive surface of implants in case of adequate primary fixation of the cup substantially contribute to the quality of its osseointegration. Greater rigidity of fixation verified by pull-out tests enables to insert angular stable screws into the gaps in the proximal part of the cup. There is still room for improvement in treating the bone defect. The application of allogenic bone grafts into the defects and spaces between the ribs of the TC cup is more challenging than the use of augmentation in the systems with trabecular titanium. Based on the evaluation of CT scans, remodelling of the transplanted bone occurs, therefore the defect zone is reduced. CONCLUSIONS The oval-shaped uncemented cup - type TC meets the requirements placed on a state-of the art revision implant, moreover its specific construction helps improve the conditions where another re-operation of acetabulum is necessary. By evaluating mid-term to long-term results of non-homogenous group of 36 patients (38 cups) we have obtained data on joint function comparable to similar groups with revision uncemented implants presented in our and foreign literature. Key words: revision oval-shaped cup, bone remodelling, pull-out tests, angular stable screws, computed tomography.

  8. The interaction between short-term heat-treatment and the formability of an Al-Mg-Si alloy regarding deep drawing processes

    NASA Astrophysics Data System (ADS)

    Machhammer, M.; Sommitsch, C.

    2016-11-01

    Research conducted in recent years has shown that heat-treatable Al-Mg-Si alloys (6xxx) have great potential concerning the design of lightweight car bodies. Compared to conventional deep drawing steels the field of application is limited by a lower formability. In order to minimize the disadvantage of a lower drawability a short-term heat-treatment (SHT) can be applied before the forming process. The SHT, conducted in selected areas on the initial blank, leads to a local reduction of strength aiming at the decrease of critical stress during the deep drawing process. For the successful procedure of the SHT a solid knowledge about the crucial process parameters such as the design of the SHT layout, the SHT process time and the maximum SHT temperature are urgently required. It also should be noted that the storage time between the SHT and the forming processes affects the mechanical properties of the SHT area. In this paper, the effect of diverse SHT process parameters and various storage time-frames on the major and minor strain situation of a deep drawn part is discussed by the evaluation of the forming limit diagram. For the purpose of achieving short heating times and a homogenous temperature distribution a one side contact heating tool has been used for the heat treatment in this study.

  9. Development of a Hybrid Deep Drawing Process to Reduce Springback of AHSS

    NASA Astrophysics Data System (ADS)

    Boskovic, Vladimir; Sommitsch, Christoph; Kicin, Mustafa

    2017-09-01

    In future, the steel manufacturers will strive for the implementation of Advanced High Strength Steels (AHSS) in the automotive industry to reduce mass and improve structural performance. A key challenge is the definition of optimal and cost effective processes as well as solutions to introduce complex steel products in cold forming. However, the application of these AHSS often leads to formability problems such as springback. One promising approach in order to minimize springback is the relaxation of stress through the targeted heating of materials in the radius area after the deep drawing process. In this study, experiments are conducted on a Dual Phase (DP) and TWining Induced Plasticity (TWIP) steel for the process feasibility study. This work analyses the influence of various heat treatment temperatures on the springback reduction of deep drawn AHSS.

  10. Modified Diet Recipes for Army Medical Facilities

    DTIC Science & Technology

    1983-10-20

    Mashed 1/2 cup 100 Whole .1-2" diam. 100 Dried Beans 1/2 cup 100 Kidney Corn 1/3 cup 80 Macaroni 1/2 cup 70 Noodles 1/2 cup 80 Peas, green 1/2...5 mg sodium Na/R Bread or Toast Cereal, Cooked Na/R Potato, Sweet Na/R Mashed Na/R Whole Dried Beans Kidney Corn Macaroni Noodles Peas...cup Mashed - no milk 1/3 cup Baked-1/3 of 2-1/4 diam. Diced 1/3 cup Mashed - no milk 1/3 cup Beans, Kidney 1/3 cup Corn Macaroni Noodles

  11. Dynamic analysis of six-bar mechanical press for deep drawing

    NASA Astrophysics Data System (ADS)

    Mitsi, S.; Tsiafis, I.; Bouzakis, K. D.

    2017-02-01

    This paper analyzes the dynamical behavior of a six-bar linkage used in mechanical presses for metal forming such as deep drawing. In the under study mechanism, a four-bar linkage is connected to a slider through an articulated binary link. The motion of the six-bar linkage is studied by kinematic analysis developing an analytical method. Furthermore, using an iterative method and d’ Alembert’s principle, the joint forces and drive moment are evaluated considering joint frictions. The simulation results obtained with a MATLAB program are validated by comparing the theoretical values of the input moment with the ones obtained from the conservation of energy law.

  12. Source and transport of human enteric viruses in deep municipal water supply wells

    USGS Publications Warehouse

    Bradbury, Kenneth R.; Borchardt, Mark A.; Gotkowitz, Madeline; Spencer, Susan K.; Zhu, Jun; Hunt, Randall J.

    2013-01-01

    Until recently, few water utilities or researchers were aware of possible virus presence in deep aquifers and wells. During 2008 and 2009 we collected a time series of virus samples from six deep municipal water-supply wells. The wells range in depth from approximately 220 to 300 m and draw water from a sandstone aquifer. Three of these wells draw water from beneath a regional aquitard, and three draw water from both above and below the aquitard. We also sampled a local lake and untreated sewage as potential virus sources. Viruses were detected up to 61% of the time in each well sampled, and many groundwater samples were positive for virus infectivity. Lake samples contained viruses over 75% of the time. Virus concentrations and serotypes observed varied markedly with time in all samples. Sewage samples were all extremely high in virus concentration. Virus serotypes detected in sewage and groundwater were temporally correlated, suggesting very rapid virus transport, on the order of weeks, from the source(s) to wells. Adenovirus and enterovirus levels in the wells were associated with precipitation events. The most likely source of the viruses in the wells was leakage of untreated sewage from sanitary sewer pipes.

  13. An incremental analysis of a deep drawing steel’s material behaviour undergoing the predeformation using drawbeads

    NASA Astrophysics Data System (ADS)

    Schmid, H.; Suttner, S.; Merklein, M.

    2017-09-01

    Nowadays lightweight design in metal forming processes leads to complex deep drawing geometries, which can cause multiple damages. Therefore, drawbeads are one way to regulate and control material flow during the forming process. Not only in research, but also in industrial practice, it could be determined that material is work hardened passing drawbead geometries. It particularly means when material is pre-deformed with tensile and alternating bending loads. This incident also gives the opportunity to utilize it in a reasonable way if examined properly. To investigate these findings, a process oriented and comprehensive analysis of the material behaviour during these forming operations is needed. In this paper, sheet metal strips are linearly drawn through a drawbead and stopped after passing the drawbead. Within this forming operation, the material undergoes non-linear straining before reaching the in-plane position again. Here, the process will be stopped to investigate a permanent strengthening local along the sheet thickness. Therefore, microhardness measurements are realized before and after passing the drawbead. Because of its common use and its wide known material data, a deep drawing steel DC will be used for these studies. Additionally, the strategy is applied to advanced high strength steel.

  14. Spoon-to-Cup Fading as Treatment for Cup Drinking in a Child with Intestinal Failure

    ERIC Educational Resources Information Center

    Groff, Rebecca A.; Piazza, Cathleen C.; Zeleny, Jason R.; Dempsey, Jack R.

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup. (Contains 2…

  15. DEEP SPACE: High Resolution VR Platform for Multi-user Interactive Narratives

    NASA Astrophysics Data System (ADS)

    Kuka, Daniela; Elias, Oliver; Martins, Ronald; Lindinger, Christopher; Pramböck, Andreas; Jalsovec, Andreas; Maresch, Pascal; Hörtner, Horst; Brandl, Peter

    DEEP SPACE is a large-scale platform for interactive, stereoscopic and high resolution content. The spatial and the system design of DEEP SPACE are facing constraints of CAVETM-like systems in respect to multi-user interactive storytelling. To be used as research platform and as public exhibition space for many people, DEEP SPACE is capable to process interactive, stereoscopic applications on two projection walls with a size of 16 by 9 meters and a resolution of four times 1080p (4K) each. The processed applications are ranging from Virtual Reality (VR)-environments to 3D-movies to computationally intensive 2D-productions. In this paper, we are describing DEEP SPACE as an experimental VR platform for multi-user interactive storytelling. We are focusing on the system design relevant for the platform, including the integration of the Apple iPod Touch technology as VR control, and a special case study that is demonstrating the research efforts in the field of multi-user interactive storytelling. The described case study, entitled "Papyrate's Island", provides a prototypical scenario of how physical drawings may impact on digital narratives. In this special case, DEEP SPACE helps us to explore the hypothesis that drawing, a primordial human creative skill, gives us access to entirely new creative possibilities in the domain of interactive storytelling.

  16. Experimental Investigation of the Robinson-Type Cup Anemometer

    NASA Technical Reports Server (NTRS)

    Brevoort, M J; Joyner, U T

    1936-01-01

    This report presents the results of wind tunnel tests on a Robinson-type anemometer. The investigation covered force measurements on individual cups, as well as static and dynamic torque measurements and calibrations on complete cup wheels. In the tests on individual cups 5 cup forms were used and in the measurements on complete cup wheels 4 cup wheels with 3 arm lengths for each cup wheel were tested. All the results are presented in graphical form.

  17. Short-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery.

    PubMed

    Mohaddes, Maziar; Rolfson, Ola; Kärrholm, Johan

    2015-02-01

    The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were performed using a TM cup. We compared the risk of reoperation and re-revision for TM cups and the 2 other most frequently used cup designs in acetabular revisions reported to the SHAR. The hypothesis was that the performance of TM cups is as good as that of established designs in the short term. The study population consisted of 2,384 patients who underwent 2,460 revisions during the period 2006 through 2012. The most commonly used cup designs were the press-fit porous-coated cup (n = 870), the trabecular metal cup (n = 805), and the cemented all-polyethylene cup (n = 785). 54% of the patients were female, and the median age at index revision was 72 (19-95) years. Reoperation was defined as a second surgical intervention, and re-revision-meaning exchange or removal of the cup-was used as endpoint. The mean follow-up time was 3.3 (0-7) years. There were 215 reoperations, 132 of which were re-revisions. The unadjusted and adjusted risk of reoperation or re-revision was not significantly different for the TM cup and the other 2 cup designs. Our data support continued use of TM cups in acetabular revisions. Further follow-up is necessary to determine whether trabecular metal cups can reduce the re-revision rate in the long term, compared to the less costly porous press-fit and cemented designs.

  18. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    PubMed

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  19. Our Everyday Cup of Coffee: The Chemistry behind Its Magic

    NASA Astrophysics Data System (ADS)

    Petracco, Marino

    2005-08-01

    Coffee beverages are so popular all over the world that there is hardly any need to describe them. But underlying this seemingly commonplace beverage there is a whole realm worth serious scientific study. The complexity of the raw seed matrix, made even more intricate when roasted, requires a deep understanding of its chemical nature. While coffee is not consumed for nutritional purposes, it is appreciated for its taste appeal along with its stimulating effects on mental and physical activity. The attention to quality is of paramount importance to both of these aspects to supply the customers with a pleasant and wholesome product. The chemical approach to the sensory sphere has seen the development of increasingly sophisticated analytical methods where the parts per billion of volatile aromas are not the ultimate frontier of detection limits. In spite of the progress of instrumental techniques, the cup-testing approach still remains the final assessment tool to obtain the approval for choosing the right plant and for conveying the product to the market. This is even truer when espresso, the fashionable type of coffee brewing methods, is considered.

  20. Acoustic Performance of 3D Printed Nanocomposite Earmuff

    PubMed Central

    Ahmadi, Saeid; Nassiri, Parvin; Ghasemi, Ismaeil; Monazzam Ep, Mohammad R.

    2016-01-01

    Introduction: Hearing protection devices are one of the primary noise reduction tools in developing countries. This study is intended to produce and apply acrylonitrile butadiene styrene (ABS)/clay nanocomposites to fabricate a laboratory single cup earmuffs and then compare it with double cup and single cup pure ABS earmuffs in terms of noise attenuation performance and comfort. In addition, the noise attenuation performance of single cup pure ABS earmuffs is compared with double cup pure ABS earmuffs. Methods: ABS/nanoclay filament was fabricated using a twin screw extruder. A three dimensional (3D) printing machine and a 3D model of earcup, designed by solid work software, were applied to print single and double cup earmuffs using ABS/nanoclay composite and pure ABS filaments. Finally, using an acoustic test fixture, objective noise attenuation test was performed on three different types of earmuffs, including with and without nano material and a secondary cup. Moreover, earmuffs weight was measured as a comfort component. Results: Insertion loss and calculated noise reduction rating (NRR) of single cup ABS/nanoclay earmuffs (NRR=19.4 dB) and double cup pure ABS earmuffs (NRR=18.93 dB) were improved in comparison with single cup pure ABS earmuffs (NRR=15.7 dB). Additionally, both single cup earmuffs were significantly lighter than double cup earmuffs. Although single cup nano and double cup earmuffs had nearly the same attenuation performance, single cup nano earmuffs were 74 gr lighter than double cup earmuffs, so with reference to comfort, single cup nano earmuffs will probably be more acceptable. Conclusions: From this survey it might be concluded that, even though single cup ABS/nanoclay earmuffs was lighter than double cup pure ABS earmuffs, it had approximately more attenuation performance in comparison with double cup pure ABS earmuffs. Consequently, users are probably more prone to wear light- weight single cup ABS/nanoclay earmuffs as a result of improved comfort. In short, ABS/nanoclay composite can be considered a good choice in products with the necessity of high acoustic performance and low weight. PMID:26234977

  1. Co-ordination of NDH and Cup proteins in CO2 uptake in cyanobacterium Synechocystis sp. PCC 6803.

    PubMed

    Han, Xunling; Sun, Nan; Xu, Min; Mi, Hualing

    2017-06-01

    High and low affinity CO2-uptake systems containing CupA (NDH-1MS) and CupB (NDH-1MS'), respectively, have been identified in Synechocystis sp. PCC 6803, but it is yet unknown how the complexes function in CO2 uptake. In this work, we found that deletion of cupB significantly lowered the growth of cells, and deletion of both cupA and cupB seriously suppressed the growth below pH 7.0 even under 3% CO2. The rate of photosynthetic oxygen evolution was decreased slightly by deletion of cupA but significantly by deletion of cupB and more severely by deletion of both cupA and cupB, especially in response to changed pH conditions under 3% CO2. Furthermore, we found that assembly of CupB into NDH-1MS' was dependent on NdhD4 and NdhF4. NDH-1MS' was not affected in the NDH-1MS-degradation mutant and NDH-1MS was not affected in the NDH-1MS'-degradation mutants, indicating the existence of independent CO2-uptake systems under high CO2 conditions. The light-induced proton gradient across thylakoid membranes was significantly inhibited in ndhD-deletion mutants, suggesting that NdhDs functions in proton pumping. The carbonic anhydrase activity was suppressed partly in the cupA- or cupB-deletion mutant but severely in the mutant with both cupA and cupB deletion, indicating that CupA and CupB function in conversion of CO2 to HCO3-. In turn, deletion of cup genes lowered the transthylakoid membrane proton gradient and deletion of ndhDs decreased the CO2 hydration. Our results suggest that NDH-1M provides an alkaline region to activate Cup proteins involved in CO2 uptake. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  2. 77 FR 2659 - Airworthiness Directives; Cessna Aircraft Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ...), and of the bearing cup for corrosion, turned cup, or clearance that exceeds limits, and repair as... cup for corrosion, turned cup, or clearance that exceeds limits, and repair if necessary; measuring... on the metal), and of the bearing cup for corrosion, turned cup, or clearance that exceeds limits...

  3. Cup tool use by squirrel monkeys.

    PubMed

    Buckmaster, Christine L; Hyde, Shellie A; Parker, Karen J; Lyons, David M

    2015-12-01

    Captive-born male and female squirrel monkeys spontaneously 'invented' a cup tool use technique to Contain (i.e., hold and control) food they reduced into fragments for consumption and to Contain water collected from a valve to drink. Food cup use was observed more frequently than water cup use. Observations indicate that 68% (n = 39/57) of monkeys in this population used a cup (a plastic slip cap) to Contain food, and a subset of these monkeys, 10% (n = 4/39), also used a cup to Contain water. Cup use was optional and did not replace, but supplemented, the hand/arm-to-mouth eating and direct valve drinking exhibited by all members of the population. Strategies monkeys used to bring food and cups together for food processing activity at preferred upper-level perching areas, in the arboreal-like environment in which they lived, provides evidence that monkeys may plan food processing activity with the cups. Specifically, prior to cup use monkeys obtained a cup first before food, or obtained food and a cup from the floor simultaneously, before transporting both items to upper-level perching areas. After food processing activity with cups monkeys rarely dropped the cups and more often placed the cups onto perching. Monkeys subsequently returned to use cups that they previously placed on perching after food processing activity. The latter behavior is consistent with the possibility that monkeys may keep cups at preferred perching sites for future food processing activity and merits experimental investigation. Reports of spontaneous tool use by squirrel monkeys are rare and this is the first report of population-level tool use. These findings offer insights into the cognitive abilities of squirrel monkeys and provide a new context for behavior studies with this genus and for comparative studies with other primates. © 2015 Wiley Periodicals, Inc.

  4. Enhancing Deep Learning: Lessons from the Introduction of Learning Teams in Management Education in France

    ERIC Educational Resources Information Center

    Borredon, Liz; Deffayet, Sylvie; Baker, Ann C.; Kolb, David

    2011-01-01

    Drawing from the reflective teaching and learning practices recommended in influential publications on learning styles, experiential learning, deep learning, and dialogue, the authors tested the concept of "learning teams" in the framework of a leadership program implemented for the first time in a top French management school…

  5. Wet cupping therapy restores sympathovagal imbalances in cardiac rhythm.

    PubMed

    Arslan, Müzeyyen; Yeşilçam, Nesibe; Aydin, Duygu; Yüksel, Ramazan; Dane, Senol

    2014-04-01

    A recent study showed that cupping had therapeutic effects in rats with myocardial infarction and cardiac arrhythmias. The current studyaimed to investigate the possible useful effects of cupping therapy on cardiac rhythm in terms of heart rate variability (HRV). Forty healthy participants were included. Classic wet cupping therapy was applied on five points of the back. Recording electrocardiography (to determine HRV) was applied 1 hour before and 1 hour after cupping therapy. All HRV parameters increased after cupping therapy compared with before cupping therapy in healthy persons. These results indicate for the first time in humans that cupping might be cardioprotective. In this study, cupping therapy restored sympathovagal imbalances by stimulating the peripheral nervous system.

  6. Local laser-strengthening: Customizing the forming behavior of car body steel sheets

    NASA Astrophysics Data System (ADS)

    Wagner, M.; Jahn, A.; Beyer, E.; Balzani, D.

    2018-05-01

    Future trends in designing lightweight components especially for automotive applications increasingly require complex and delicate structures with highest possible level of capacity [1]. The manufacturing of metallic car body components is primarily realized by deep or stretch drawing. The forming process of especially cold rolled and large-sized components is typically characterized by inhomogeneous stress and strain distributions. As a result, the avoidance of undesirable deep drawing effects like earing and local necking is among the greatest challenges in forming complex car body structures [2]. Hence, a novel local laser-treatment approach with the objective of customizing the forming behavior of car body steel sheets is currently explored.

  7. Fixation strength analysis of cup to bone material using finite element simulation

    NASA Astrophysics Data System (ADS)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; van der Heide, Emile

    2016-04-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw inside of cup is effective; however, it has little effect in whole fixation. Therefore, an acetabular cup with good fixation, easy manufacture and easy installation is required. This paper is aiming at evaluating and proposing a new cup fixation design. To prove the strength of the present cup fixation design, the finite element simulation of three dimensional cup with new fixation design was performed. The present cup design was examined with twist axial and radial rotation. Results showed that the proposed cup design was better than the general version.

  8. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    PubMed

    Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram

    2016-03-01

    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.

  9. [Progress of researches on the mechanism of cupping therapy].

    PubMed

    Cui, Shuai; Cui, Jin

    2012-12-01

    Cupping therapy of Chinese medicine is able to relieve a variety of diseases or clinical conditions, which results from the comprehensive effects of multiple types of stimulation exerted onto the regional acupoint areas. Among the stimuli, the negative pressure from cupping is one of the main factors inducing therapeutic effects. In the present paper, the authors review development of researches on the underlying mechanism of therapeutic effects of cupping-negative pressure from 1) the factor of intra-cup negative pressure; 2) influence of intra-cup negative pressure on cup-blackspot formation; 3) influence of cupping on regional blood vessels and blood flow; 4) effect of cupping on regional ultrastructure of the capillary in the raw-surface tissue; 5) effect of cupping-negative pressure on regional endothelial cells; and 6) biological effects of negative pressure drainage. Generally, cupping induced negative pressure can dilate local blood vessels to improve microcirculation, promote capillary endothelial cells repair, accelerate granulation and angiogenesis, etc., in the regional tissues, normalizing the patients' functional state at last.

  10. Vacuum foil insulation system

    DOEpatents

    Hanson, John P.; Sabolcik, Rudolph E.; Svedberg, Robert C.

    1976-11-16

    In a multifoil thermal insulation package having a plurality of concentric cylindrical cups, means are provided for reducing heat loss from the penetration region which extends through the cups. At least one cup includes an integral skirt extending from one end of the cup to intersection with the penetration means. Assembly of the insulation package with the skirted cup is facilitated by splitting the cup to allow it to be opened up and fitted around the other cups during assembly.

  11. An updated review of the efficacy of cupping therapy.

    PubMed

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted.

  12. 78 FR 32990 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ...] Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA AGENCY: Coast... ``Louis Vuitton Cup, Red Bull Youth America's Cup and the 34th America's Cup'' regatta scheduled from July... associated with the 34th America's Cup sailing events taking place adjacent to the City of San Francisco...

  13. [Impacts on skin blood flow under moving cupping along meridians in different directions].

    PubMed

    Tian, Yu-Ying; Wang, Guang-Jun; Huang, Tao; Jia, Shu-Yong; Zhang, Yu-Qin; Zhang, Wei-Bo

    2013-03-01

    To compare the impacts on skin blood flow between moving cupping following the meridian running direction and that against the running direction. JLG-2 meridian cupping drainage instru ment was used for moving cupping on the back along the Bladder Meridian running course in either single direction for 20 times. The cupping device was Bian stone cup, 44 mm in inner diameter, negative pressure from -0.03 to -0.04 MPa. PeriScan PIM II laser Doppler perfusion imager was used to observe the changes in skin blood flow on the running course of the Bladder Meridian with cup moved up and down and in the same region on the contralateral Bladder Meridian. Blood flow was measured before cupping, at the immediate time after cupping and 10 min after cupping separately. Fourteen healthy volunteers received the test. The measuring region was subdivided into a moving cupping area, an upstream area, a downstream area, a contralateral moving cupping area, a contralateral upstream area and a contralateral downstream area. The mean blood flow was calculated in each area. Blood flow was increased significantly in each area and was more apparently increased in the moving cupping area. In comparison of the changing rate of blood flow between cupping following the meridian running direction and that against the running direction, it was only found that the changing rate in the upstream area of moving cupping against the running direction was significantly higher than that following the running direction (P < 0.05). The differences were not statistically significant in comparison among the other areas. Additionally, the changing rates of blood flow in the upstream and downstream area of the Bladder Meridian were increased significantly as compared with the contralateral Bladder Meridian. The local effects are similar between moving cupping following the meridian running direction and that against the running direction. The abscopal effect of moving cupping against the running direction is superior to that following the running direction. It is suggested that the dual-directional moving cupping is applicable for the treatment of local disorders and the abscopal effect is better with moving cupping against the meridian running direction.

  14. Developing and validating a sham cupping device.

    PubMed

    Lee, Myeong Soo; Kim, Jong-In; Kong, Jae Cheol; Lee, Dong-Hyo; Shin, Byung-Cheul

    2010-12-01

    The aims of this study were to develop a sham cupping device and to validate its use as a placebo control for healthy volunteers. A sham cupping device was developed by establishing a small hole to reduce the negative pressure after suction such that inner pressure could not be maintained in the cup. We enrolled 34 healthy participants to evaluate the validity of the sham cupping device as a placebo control. The participants were informed that they would receive either real or sham cupping and were asked which treatment they thought they had received. Other sensations and adverse events related to cupping therapy were investigated. 17 patients received real cupping therapy and 17 received sham cupping. The two groups felt similar sensations. There was a tendency for subjects to feel that real cupping created a stronger sensation than sham cupping (48.9±21.4 vs 33.3±20.3 on a 100mm visual analogue scale). There were only mild to moderate adverse events observed in both groups. We developed a new sham cupping device that seems to provide a credible control for real cupping therapy by producing little or no negative pressure. This conclusion was supported by a pilot study, but more rigorous research is warranted regarding the use of this device.

  15. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    PubMed

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  16. Acetabular Cup Revision.

    PubMed

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  17. A Hybrid Spectral Clustering and Deep Neural Network Ensemble Algorithm for Intrusion Detection in Sensor Networks

    PubMed Central

    Ma, Tao; Wang, Fen; Cheng, Jianjun; Yu, Yang; Chen, Xiaoyun

    2016-01-01

    The development of intrusion detection systems (IDS) that are adapted to allow routers and network defence systems to detect malicious network traffic disguised as network protocols or normal access is a critical challenge. This paper proposes a novel approach called SCDNN, which combines spectral clustering (SC) and deep neural network (DNN) algorithms. First, the dataset is divided into k subsets based on sample similarity using cluster centres, as in SC. Next, the distance between data points in a testing set and the training set is measured based on similarity features and is fed into the deep neural network algorithm for intrusion detection. Six KDD-Cup99 and NSL-KDD datasets and a sensor network dataset were employed to test the performance of the model. These experimental results indicate that the SCDNN classifier not only performs better than backpropagation neural network (BPNN), support vector machine (SVM), random forest (RF) and Bayes tree models in detection accuracy and the types of abnormal attacks found. It also provides an effective tool of study and analysis of intrusion detection in large networks. PMID:27754380

  18. A Hybrid Spectral Clustering and Deep Neural Network Ensemble Algorithm for Intrusion Detection in Sensor Networks.

    PubMed

    Ma, Tao; Wang, Fen; Cheng, Jianjun; Yu, Yang; Chen, Xiaoyun

    2016-10-13

    The development of intrusion detection systems (IDS) that are adapted to allow routers and network defence systems to detect malicious network traffic disguised as network protocols or normal access is a critical challenge. This paper proposes a novel approach called SCDNN, which combines spectral clustering (SC) and deep neural network (DNN) algorithms. First, the dataset is divided into k subsets based on sample similarity using cluster centres, as in SC. Next, the distance between data points in a testing set and the training set is measured based on similarity features and is fed into the deep neural network algorithm for intrusion detection. Six KDD-Cup99 and NSL-KDD datasets and a sensor network dataset were employed to test the performance of the model. These experimental results indicate that the SCDNN classifier not only performs better than backpropagation neural network (BPNN), support vector machine (SVM), random forest (RF) and Bayes tree models in detection accuracy and the types of abnormal attacks found. It also provides an effective tool of study and analysis of intrusion detection in large networks.

  19. Through-process modelling of texture and anisotropy in AA5182

    NASA Astrophysics Data System (ADS)

    Crumbach, M.; Neumann, L.; Goerdeler, M.; Aretz, H.; Gottstein, G.; Kopp, R.

    2006-07-01

    A through-process texture and anisotropy prediction for AA5182 sheet production from hot rolling through cold rolling and annealing is reported. Thermo-mechanical process data predicted by the finite element method (FEM) package T-Pack based on the software LARSTRAN were fed into a combination of physics based microstructure models for deformation texture (GIA), work hardening (3IVM), nucleation texture (ReNuc), and recrystallization texture (StaRT). The final simulated sheet texture was fed into a FEM simulation of cup drawing employing a new concept of interactively updated texture based yield locus predictions. The modelling results of texture development and anisotropy were compared to experimental data. The applicability to other alloys and processes is discussed.

  20. Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.

    PubMed

    Equy, Véronique; David-Tchouda, Sandra; Dreyfus, Michel; Riethmuller, Didier; Vendittelli, Françoise; Cabaud, Victoire; Langer, Bruno; Margier, Jennifer; Bosson, Jean-Luc; Schaal, Jean-Patrick

    2015-12-15

    Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup. This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears. 335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events. While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries. www.clinicaltrials.gov : NCT01058200 on Jan. 27 2010.

  1. Prediction of thinning of the sheet metal in the program AutoForm and its experimental verification

    NASA Astrophysics Data System (ADS)

    Fedorko, M.; Urbánek, M.; Rund, M.

    2017-02-01

    The manufacture of press-formed parts often involves deep-drawing operations. Deep drawing, however, can be deemed an industrial branch in its own right. Today, many experimental as well as numerical methods are available for designing and optimizing deep drawing operations. The best option, however, is to combine both approaches. The present paper describes one such investigation. Here, measurements and numerical simulation were used for mapping the impact of anisotropy on thickness variation in a spherical-shaped drawn part of DC01 steel. Variation in sheet thickness was measured on spherical-shaped drawn parts of various geometries by means of two cameras, and evaluated with digital image correlation using the ARAMIS software from the company GOM. The forming experiment was carried out on an INOVA 200 kN servohydraulic testing machine in which the force vs. piston displacement curve was recorded. The same experiment was then numerically simulated and analyzed using the AUTOFORM software. Various parameters were monitored, such as thinning, strain magnitude, formability, and others. For the purpose of this simulation, a series of mechanical tests was conducted to obtain descriptions of the experimental material of 1.5 mm thickness. A material model was constructed from the tests data involving the work-hardening curve, the impact of anisotropy, and the forming limit diagram. Specifically, these tests included tensile tests, the Nakajima test, and the stacked test, which were carried out to determine materials data for the model. The actual sheet thickness was measured on a sectioned spherical-shaped drawn part using a NIKON optical microscope. The variations in thickness along defined lines on the sectioned drawn part were compared with the numerical simulations data using digital image correlation. The above-described experimental programme is suitable for calibrating a material model for any computational software and can correctly solve deep-drawing problems.

  2. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    PubMed Central

    Shawaf, Turke; El-Deeb, Wael; Hussen, Jamal; Hendi, Mahmoud; Al-Bulushi, Shahab

    2018-01-01

    Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama) on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml) size with narrow mouths were used. A manual pump (sucking cups) was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusions: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  3. An Updated Review of the Efficacy of Cupping Therapy

    PubMed Central

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Background Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Method Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. Results 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Conclusions Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted. PMID:22389674

  4. Combining the pressure effect with local heat treatment for improving the sheet metal forming process

    NASA Astrophysics Data System (ADS)

    Palumbo, G.; Piccininni, A.; Guglielmi, P.; Sorgente, D.; Tricarico, L.

    2016-08-01

    The present work deals with the advantages in the Hydromechanical Deep Drawing (HDD) when AA5754 Tailored Heat Treated Blanks (THTBs) are adopted. It is well known that the creation of a suitable distribution of material properties increases the process performance. When non heat-treatable alloys are considered, the THTB approach can be successfully applied to increase the Limit Drawing Ratio (LDR) by changing the peripheral zone into the annealed state starting from a cold-worked blank. If this approach is combined with the advantages of a counterpressure, even more remarkable improvements can be achieved. Due to the large number of involved parameters, the optimized design of both the local treatment and the pressure profile were investigated coupling an axial symmetric Finite Element model with the integration platform modeFRONTIER. Results confirmed the possibility of increasing the LDR from 2.0 (Deep Drawing using a blank in the annealed state) up to about 3.0 if combining the adoption of a THTB with the optimal pressure profile.

  5. SPECIAL ACTIVITIES SUPPLEMENTAL TO AND RELATED TO THE ART PROGRAM AT DEEP RIVER OUTDOOR EDUCATION CENTER.

    ERIC Educational Resources Information Center

    Gary City Public School System, IN.

    A CURRICULUM GUIDE DEALING WITH VARIOUS SUBJECT AREAS WAS PREPARED FOR POSSIBLE STUDY ACTIVITIES THAT WOULD USE THE LEARNING RESOURCES AVAILABLE AT THE DEEP RIVER OUTDOOR EDUCATION CENTER IN GARY, INDIANA. ACTIVITIES GUIDES ARE PRESENTED FOR (1) ART ACTITIVIES RELATED TO DESIGN, COLOR, LANDSCAPE REPRESENTATION, PAPER CONSTRUCTION, DRAWING, PRINT…

  6. 10-year results of the uncemented Allofit press-fit cup in young patients.

    PubMed

    Streit, Marcus R; Weiss, Stefan; Andreas, Franziska; Bruckner, Thomas; Walker, Tilman; Kretzer, J Philippe; Ewerbeck, Volker; Merle, Christian

    2014-08-01

    Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21-60) years. Mean time of follow-up evaluation was 11 (10-12) years. At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92-99). Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low.

  7. A novel method to assess primary stability of press-fit acetabular cups.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2014-11-01

    Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs. © IMechE 2014.

  8. Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction-First Clinical Results.

    PubMed

    Schumann, Steffen; Sato, Yoshinobu; Nakanishi, Yuki; Yokota, Futoshi; Takao, Masaki; Sugano, Nobuhiko; Zheng, Guoyan

    2015-11-01

    In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.

  9. Eat for Health

    MedlinePlus

    ... pasta, or cereal Vegetables 4-5 1 cup raw leafy vegetables ½ cup cooked vegetables 6 oz vegetable juice Fruits 4-5 1 medium fruit ¼ cup dried fruit ½ cup fresh, frozen, or canned fruit ½ cup fruit juice Low-fat or fat-free milk and milk products 2- ...

  10. New is the well-forgotten old: The use of dry cupping in musculoskeletal medicine.

    PubMed

    Rozenfeld, Evgeni; Kalichman, Leonid

    2016-01-01

    Cupping is an ancient technique used in treating pain and various disorders. Different techniques have been developed over time, however, applying a cup to create suction over a painful area, is common to all. Dry or fire cupping, used on the intact skin, leaves bluish circular hematomas. Recently, interest in cupping has re-emerged and subsequently, several studies have begun to investigate the mechanisms of cupping therapy. Mechanically, cupping increases blood circulation, whereas physiologically it activates the immune system and stimulates the mechanosensitive fibers, thus leading to a reduction in pain. There is initial scientific evidence that dry cupping is able to reduce musculoskeletal pain. Since cupping is an inexpensive, noninvasive and low-risk (if performed by a trained practitioner) therapeutic modality, we believe that it should be included in the arsenal of musculoskeletal medicine. It is essential to perform additional studies clarifying the biological mechanism and clinical effects of cupping. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Jacketed lamp bulb envelope

    DOEpatents

    MacLennan, Donald A.; Turner, Brian P.; Gitsevich, Aleksandr; Bass, Gary K.; Dolan, James T.; Kipling, Kent; Kirkpatrick, Douglas A.; Leng, Yongzhang; Levin, Izrail; Roy, Robert J.; Shanks, Bruce; Smith, Malcolm; Trimble, William C.; Tsai, Peter

    2001-01-01

    A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

  12. Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

    PubMed

    Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John

    2013-11-01

    Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.

  13. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    PubMed

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  14. History of cupping (Hijama): a narrative review of literature.

    PubMed

    Qureshi, Naseem Akhtar; Ali, Gazzaffi Ibrahim; Abushanab, Tamer Shaban; El-Olemy, Ahmed Tawfik; Alqaed, Meshari Saleh; El-Subai, Ibrahim S; Al-Bedah, Abdullah M N

    2017-05-01

    Cupping (Hijama in Arabic) is an ancient, holistic method for the treatment of a variety of diseases. Though the exact origin of cupping therapy is a matter of controversy, its use has been documented in early Egyptian and Chinese medical practices. Diverse human civilizations have contributed to the historical development and continuation of cupping therapy. This narrative review describes the history of cupping, historical definitions, cupping instruments and uses of cupping therapy. Electronic searches of relevant databases (PubMed, Google Scholar and OvidSP) were conducted using keywords and Boolean operators. Manual searches and references of published articles and books were also conducted. A number of articles (N = 625) were retained for extensive review, and finally 83 articles were included in this paper. The historical descriptions of cupping therapy were found in ancient human civilizations of the Eastern and Western world. There were inconsistent data concerning the origin of cupping, definitions, instruments, procedures, definite advancements and research in Hijama over centuries. Cupping therapy fell out of favor in 17th and mid-18th centuries but recovered popularity in modern medicine. Currently, cupping therapy is used for health promotion, prophylaxis and treatment of a variety of diseases around the world. Cupping therapy with a good safety profile has a checkered history and is a well-recognized traditional method for managing medical conditions. Currently, the scope of cupping therapy is expanding, and a growing body of research is providing additional evidence-based data for the further advancement of cupping therapy in the treatment of a variety of diseases.

  15. Study of wear performance of deep drawing tooling

    NASA Astrophysics Data System (ADS)

    Naranje, Vishal G.; Karthikeyan, Ram; Nair, Vipin

    2017-09-01

    One of the most common challenges for many of the mechanical engineers and also in the field of materials science is the issue of occurrences of wear of the material parts which is used in certain applications that involves such surface interactions. In this paper, wear behaviour of particular grade High Carbon High Chromium Steel and many most famously D2, H13, O1 known as the Viking steel has been studied, evaluated and analyzed under certain processing parameters such as speed, load, track diameter and time required for deep drawing process to know it’s the wear rate and coefficient of friction. Also, the significance of the processing parameters which is used for wear testing analysis is also examined.

  16. Recommended Dietary Menus for Use in Operational and Research Saturation Diving

    DTIC Science & Technology

    1991-05-01

    GMS MARGARINE-CORN-REG 1.0 TBSP 14.1 GMS CAKE-POUND 1.0 SLICE 33.0 GMS SNACK RAISINS-SEEDLESS 0.7 CUP 108.8 GMS NUTS - CASHEWS -DRY ROASTED 0.2 CUP 34.3...CUP 250.0 GMS TEA-INSTANT-PREP-UNSWEET 2.0 CUPS 474.0 GMS MARGARINE-CORN-REG 1.0 TBSP 14.1 GMS SNACK NUTS - CASHEWS -OIL ROASTED 0.3 CUP 39.0 GMS...GMS SNACK RAISINS-SEEDLESS 0.7 CUP 108.8 GMS NUTS - CASHEWS -DRY ROASTED 0.3 CUP 41.1 GMS NUTRIENT VALUES Kcalories 3694 Kc Carbohydrate 545.0 Gm Protein

  17. Alternative medicine: an update on cupping therapy.

    PubMed

    Chen, B; Li, M-Y; Liu, P-D; Guo, Y; Chen, Z-L

    2015-07-01

    To know the research progress of cupping therapy all over the world, the authors analyze the research of cupping therapy in recent 5 years. It indicates that cupping therapy can be applied to extensive curable disease, but has poor clinical evidence. Some improvements in the mechanism research of cupping therapy have been made, but it needs further research. The adverse events of cupping therapy attract attention. The standardization of cupping therapy has emerged. © The Author 2014. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Menses cup evaluation study.

    PubMed

    Cheng, M; Kung, R; Hannah, M; Wilansky, D; Shime, J

    1995-09-01

    To determine whether the menses cup is well tolerated by menstruating women. Prospective descriptive clinical study. Normal human volunteers in an academic research environment. Fifty-one menstruating women recruited between June to December 1991. Each participant was provided with two menses cups and an instruction sheet. Baseline information, including age, occupation, martial status, parity, description of menstrual flow, and current method used to cope with menstrual flow was collected. Subjects were asked to describe their experience with the cup at 1-, 2-, 6-, and 12-month intervals. The proportion of women who found the cup acceptable. The cup was used by 51 subjects for a total of 159 cycles. Overall, 23 women (45%) found the cup an acceptable method for coping with menses. Among 29 (57%) women who used the cup for two or more cycles, 62% found it acceptable. The menses cup may be an acceptable method for some women for coping with menstrual flow.

  19. Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty.

    PubMed

    Ozden, Vahit Emre; Dikmen, Goksel; Beksac, Burak; Tozun, Ismail Remzi

    2018-05-01

    Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Fracture prediction using modified mohr coulomb theory for non-linear strain paths using AA3104-H19

    NASA Astrophysics Data System (ADS)

    Dick, Robert; Yoon, Jeong Whan

    2016-08-01

    Experiment results from uniaxial tensile tests, bi-axial bulge tests, and disk compression tests for a beverage can AA3104-H19 material are presented. The results from the experimental tests are used to determine material coefficients for both Yld2000 and Yld2004 models. Finite element simulations are developed to study the influence of materials model on the predicted earing profile. It is shown that only the YLD2004 model is capable of accurately predicting the earing profile as the YLD2000 model only predicts 4 ears. Excellent agreement with the experimental data for earing is achieved using the AA3104-H19 material data and the Yld2004 constitutive model. Mechanical tests are also conducted on the AA3104-H19 to generate fracture data under different stress triaxiality conditions. Tensile tests are performed on specimens with a central hole and notched specimens. Torsion of a double bridge specimen is conducted to generate points near pure shear conditions. The Nakajima test is utilized to produce points in bi-axial tension. The data from the experiments is used to develop the fracture locus in the principal strain space. Mapping from principal strain space to stress triaxiality space, principal stress space, and polar effective plastic strain space is accomplished using a generalized mapping technique. Finite element modeling is used to validate the Modified Mohr-Coulomb (MMC) fracture model in the polar space. Models of a hole expansion during cup drawing and a cup draw/reverse redraw/expand forming sequence demonstrate the robustness of the modified PEPS fracture theory for the condition with nonlinear forming paths and accurately predicts the onset of failure. The proposed methods can be widely used for predicting failure for the examples which undergo nonlinear strain path including rigid-packaging and automotive forming.

  1. Biometry and spectral domain optical coherence tomography parameters in children with large cupping.

    PubMed

    Jung, Jong Jin; Baek, Seung-Hee; Kim, Ungsoo Samuel

    2013-09-01

    The purpose of this study is to investigate optic nerve head using spectral domain optical coherence tomography (SD-OCT) in children with large cupping. 111 eyes (4-10 years) were divided into three groups according to the cup to disc ratio: group 1, ≤0.3; group 2, 0.4-0.6; and group 3, ≥0.7. The rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were investigated using SD-OCT (Cirrus HD-OCT, Carl Zeiss, Jena, Germany), and the axial length and anterior chamber depth (ACD) were measured by IOL master (IOL master 500, Carl Zeiss, Jena, Germany). Next, we compared ocular biometry and SD-OCT between the three groups. The mean age of group 1 was 6.48 ± 1.42 years, 7.00 ± 1.75 years in group 2, and 6.63 ± 1.82 years in group 3 (p = 0.370). A significant difference was seen in the spherical equivalent between the groups (p = 0.001). Group 2 had the most myopic refractive errors. As the cup to disc ratio increases, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume increase significantly. When the results of ocular biometry and SD-OCT are adjusted for axial length, only disc area showed a significant correlation with cup to disc ratio (ACD: p = 0.473, rim area: p = 0.639, disc area: p = 0.005, and cup volume: p = 0.325). Axial length is the key factor determining disc size, which in turn is important for determining cup to disc ratio. Normal children with large cupping should be examined for axial length, myopic refractive errors, and disc size.

  2. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    PubMed

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (P<.001). However, both methods yielded highly correlated measurements for cup coverage (Pearson r=0.761, P<.001). The size of the acetabular cup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  3. Is cupping blister harmful?-A proteomical analysis of blister fluid induced by cupping therapy and scald.

    PubMed

    Liu, Zhidan; Chen, Chunlan; Li, Xiaoyan; Zhao, Chuang; Li, Zunyuan; Liang, Wei; Lin, Yufang

    2018-02-01

    Cupping therapy has a long history in traditional medicine especially in Asian countries. It was controversial whether cupping induced blisters are beneficial to healing effects, and the formation and content in the blisters remain unexplored. We aimed to identify and compare the molecular components of the blister fluid from the cupping therapy and the scalds to explore the necessary of inducing cupping induced blisters. Fluid sample of blisters from fifteen patients receiving cupping therapy (Cupping group) and scald burns (Scald group) were collected in this study. Proteins from the blisters were separated by two-dimensional electrophoresis (2D-gel) and further analyzed by mass spectrometry. In addition, the changes in particular proteins were confirmed by Western blotting. The protein components are significantly different between blister from cupping therapy and scalds. The immune responses, oxidative stress and metabolic related proteins (Ig lambda-2 chain C regions, Ig gamma-1 chain C region, hemopexin, prdx2, calmodulin, succinyl-CoA ligase and tetranectin) were increased, whereas the hemoglobin subunit beta was decreased in the Cupping group compared with the Scald group. Cupping induced blisters contain several proteins which relate to the activation of certain immune pathways including anti-oxidation, anti-apoptosis, tissue repairing and metabolic regulation. This proteomic analysis may indicate a significant clue to the mechanism study of cupping. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. 77 FR 22706 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ...] Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA AGENCY: Coast... regulation and temporary safety zone proposed for those portions of the ``America's Cup World Series,'' the ``Louis Vuitton Cup'' challenger selection series, and the ``America's Cup Finals Match'' sailing regattas...

  5. 78 FR 36426 - Safety Zone; Queen's Cup; Lake Michigan; Milwaukee, WI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ...-AA00 Safety Zone; Queen's Cup; Lake Michigan; Milwaukee, WI AGENCY: Coast Guard, DHS. ACTION: Temporary... Lake Michigan due to the 2013 Queen's Cup Race. This temporary safety zone is necessary to protect the... Queen's Cup Regatta. The Queen's Cup Regatta is a race from Milwaukee, WI to Ludington, MI that is...

  6. Exploring Volumetrically Indexed Cups

    ERIC Educational Resources Information Center

    Jones, Dustin L.

    2011-01-01

    This article was inspired by a set of 12 cylindrical cups, which are volumetrically indexed; that is to say, the volume of cup "n" is equal to "n" times the volume of cup 1. Various sets of volumetrically indexed cylindrical cups are explored. I demonstrate how this children's toy is ripe for mathematical investigation, with connections to…

  7. Effect of Seed Density on Splash Cup Seed Dispersal

    NASA Astrophysics Data System (ADS)

    Wigger, Patrick; Pepper, Rachel

    2017-11-01

    Splash cup plants are plants that utilize a small, mm-sized cup filled with seeds as a method of seed dispersal. The cup uses kinetic energy of an incident raindrop in order to project the seeds away from the plant up to 1 meter. The dispersal distance is important to ensure the offspring are not clustered too tightly to the parent plant. It has previously been found that a cup angle of 40 degrees to the horizontal is optimal for maximum dispersal of water from cups with no seeds. In this study we examine if the 40 degree cup is optimal for cups containing seeds with varying densities. We released uniform water drops above 5.0 mm 3D printed models of splash cups, using 1.0 mm plastic and glass microspheres of varying densities to simulate seeds. We observed the dispersal characteristics of each bead type by measuring the final seed locations after each splash, and by recording high speed video to determine the angle and velocity of the seeds as they exited the cup.

  8. Retinal and anterior eye compartments derive from a common progenitor pool in the avian optic cup

    PubMed Central

    Venters, Sara J.; Cuenca, Paulina D.

    2011-01-01

    Purpose The optic cup is created through invagination of the optic vesicle. The morphogenetic rearrangement creates a double-layered cup, with a hinge (the Optic Cup Lip) where the epithelium bends back upon itself. Shortly after the optic cup forms, it is thought to be sub-divided into separate lineages: i) pigmented epithelium in the outer layer; ii) presumptive iris and ciliary body at the most anterior aspect of the inner layer; and iii) presumptive neural retina in the remainder of the inner layer. We test the native developmental potential of the anterior cup to determine if it normally contributes to the retina. Methods Vital dye and green fluorescent protein (GFP) expressing replication-incompetent retroviral vectors were used to label cells in the nascent optic cup and follow their direct progeny throughout development. Label was applied to either the optic cup lip (n=40), or to the domain just posterior to the lip (n=20). Retroviral labeling is a permanent lineage marker and enabled the analysis of advanced stages of development. Results Labeling within the optic cup gave rise to labeled progeny in the posterior optic cup that differentiated as neural retina (20 of 20). In contrast, labeling cells in the optic cup lip gave rise to progeny of labeled cells arrayed in a linear progression, from the lip into the neural retina (36 of 40). Label was retained in cells at the optic cup lip, regardless of age at examination. In older embryos, labeled progeny delaminated from the optic cup lip to differentiate as muscle of the pupillary margin. Conclusions The data show that the cells at the optic cup lip are a common progenitor population for pigmented epithelium, anterior eye tissues (ciliary body, iris, and pupillary muscle) and retinal neurons. The findings are supportive of an interpretation where the optic cup lip is a specialized niche containing a multipotent progenitor population. PMID:22219630

  9. Imitation, Inspiration, and Creation: Cognitive Process of Creative Drawing by Copying Others' Artworks.

    PubMed

    Okada, Takeshi; Ishibashi, Kentaro

    2017-09-01

    To investigate the cognitive processes underlying creative inspiration, we tested the extent to which viewing or copying prior examples impacted creative output in art. In Experiment 1, undergraduates made drawings under three conditions: (a) copying an artist's drawing, then producing an original drawing; (b) producing an original drawing without having seen another's work; and (c) copying another artist's work, then reproducing that artist's style independently. We discovered that through copying unfamiliar abstract drawings, participants were able to produce creative drawings qualitatively different from the model drawings. Process analyses suggested that participants' cognitive constraints became relaxed, and new perspectives were formed from copying another's artwork. Experiment 2 showed that exposure to styles of artwork considered unfamiliar facilitated creativity in drawing, while styles considered familiar did not do so. Experiment 3 showed that both copying and thoroughly viewing artwork executed using an unfamiliar style facilitated creativity in drawing, whereas merely thinking about alternative styles of artistic representation did not do so. These experiments revealed that deep encounters with unfamiliar artworks-whether through copying or prolonged observation-change people's cognitive representations of the act of drawing to produce novel artwork. Copyright © 2016 Cognitive Science Society, Inc.

  10. KSC-04PD-1316

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. In the Orbiter Processing Facility, Mike Bolt holds the Stanley Cup, won this year by the National Hockey Leagues Tampa Bay Lightning. Bolt is the Stanley Cup keeper. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. Jay Feaster, general manager of the Tampa Bay Lightning, brought the cup to KSC while on a tour. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  11. Factitious panniculitis induced by cupping therapy.

    PubMed

    Moon, Suk-Ho; Han, Hyun-Ho; Rhie, Jong-Won

    2011-11-01

    Cupping therapy is an alternative medical procedure that has been widely performed in Asian countries to relieve pain. It is known that there is no complication to this therapy, so many non-health care professionals have performed this procedure. However, there have been few reports on complications, such as iron deficiency anemia, hemorrhagic bullae, kelloids, vasovagal syncope, and foreign body reactions. Masses associated with panniculitis induced by cupping are extremely rare, and they require a unique approach.A 56-year-old woman presented with a 10-month history of multiple masses in the posterior neck and right shoulder areas. The patient repeatedly attempted cupping therapy by herself, and multiple palpable masses developed in the posterior neck and right shoulder area where cupping therapy had been performed. The masses were enlarged by repeated cupping, and they decreased in size when cupping was stopped. Among all lesions, the 2 masses with tenderness were surgically excised. The remaining masses resolved after cupping therapy was ceased. When a patient with subcutaneous mass has a history of cupping or trace of cupping marks, panniculitis induced by cupping should be suspected. The lesion seems to spontaneously resolve unless they are repeatedly stimulated. However, surgical resection is considered in patients with infections or severe tenderness as a complication.

  12. Differences in experiences of care between patients diagnosed with metastatic cancer of known and unknown primaries: mixed-method findings from the 2013 cancer patient experience survey in England

    PubMed Central

    Bracher, Mike; Drosdowsky, Allison; Richardson, Alison; Symons, John; Mileshkin, Linda; Schofield, Penny

    2017-01-01

    Objectives To explore differences in experiences of care reported in the Cancer Patient Experience Survey (CPES) between patients with cancer of unknown primary (CUP) and those with metastatic disease of known primary (non-CUP); to determine insights pertaining to the experiences of care for CUP respondents from free-text comments. Design Two separate, but related, studies, involving secondary analysis of existing data. Using frequency matching of CUP and non-CUP patients, statistical comparisons of responses to CPES questions were conducted. Free-text comments from CUP respondents were analysed thematically. Setting and participants The CPES questionnaire comprises 63 closed questions measuring 8 areas that relate to experience of care and 3 free-text questions. Questionnaires were mailed to all adult patients (aged ≥16 years) in England with cancer admitted to hospital between 1 September 2013 and 30 November 2013. Results Matched analysis of closed response items from 2992 patients found significant differences between CUP (n=1496) and non-CUP patients (n=1496): CUP patients were more likely to want more written information about their type of cancer and tests received, to receive their diagnosis from a general practitioner (GP) and have seen allied health professionals, but less likely to have understood explanations of their condition or had surgery. Freetext responses (n=3055) were coded into 17 categories and provided deeper insight regarding patient information and interactions with GPs. CPES data may include a preponderance of patients with favourable CUP subtypes and patients initially identified as CUP but whose primary was subsequently identified. Conclusions These are the first large-scale studies to explore the experiences of care of CUP patients. The significant differences identified between the experiences of CUP and non-CUP patients suggest CUP patients require more psychosocial support and specific interventions to manage diagnostic uncertainty and the multiple investigations many CUP patients face. Substantial limitations were identified with the CPES data, emphasising the need for prospective studies. PMID:28963312

  13. 77 FR 4501 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ...] RIN 1625-AA00; 1625-AA08 Special Local Regulation and Safety Zone; America's Cup Sailing Events, San... those portions of the ``America's Cup World Series,'' the ``Louis Vuitton Cup'' challenger selection series, and the ``America's Cup Finals Match'' sailing regattas that may be conducted in the waters of...

  14. [Tripolar cups].

    PubMed

    Fink, B

    2015-04-01

    Tripolar cups can be separated into constrained and unconstrained dual-mobility cups. The latter show better survival and revision rates. The main problem is the polyethylene wear. Therefore modern types of polyethylene are used in these cups. The indications for dual-mobility cups are recurrent dislocation and situations where the risk of dislocation is increased. Georg Thieme Verlag KG Stuttgart · New York.

  15. Reusable and disposable cups: An energy-based evaluation

    NASA Astrophysics Data System (ADS)

    Hocking, Martin B.

    1994-11-01

    A group of five different types of reusable and disposable hot drink cups have been analyzed in detail with respect to their overall energy costs during fabrication and use. Electricity generating methods and efficiencies have been found to be key factors in the primary energy consumption for the washing of reusable cups and a less important factor in cup fabrication. In Canada or the United States, over 500 or more use cycles, reusable cups are found to have about the same or slightly more energy consumption, use for use, as moulded polystyrene foam cups used once and then discarded. For the same area paper cups used once and discarded are found to consume less fossil fuel energy per use than any of the other cup types examined. Details of this analysis, which could facilitate the comparative assessment of other scenarios, are presented.

  16. Clinical research evidence of cupping therapy in China: a systematic literature review.

    PubMed

    Cao, Huijuan; Han, Mei; Li, Xun; Dong, Shangjuan; Shang, Yongmei; Wang, Qian; Xu, Shu; Liu, Jianping

    2010-11-16

    Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it.This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs), 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice.

  17. Micro-wear features on unique 100-Mrad cups: two retrieved cups compared to hip simulator wear study.

    PubMed

    Yamamoto, Kengo; Masaoka, Toshinori; Manaka, Masakazu; Oonishi, Hironobu; Clarke, Ian; Shoji, Hiromu; Kawanabe, Keiichi; Imakiire, Atsuhiro

    2004-04-01

    We studied the micro-wear phenomena of unique, extensively cross-linked polyethylene cups (cross-linked with 1,000 kGy-irradiation) that had been used briefly in Japan. Two retrievals (at 15 years) came from the Japanese "SOM" hip system (implanted 1971-78). These were compared to a set of 0 kGy and 500-1,500 kGy cups run in our hip simulator. The polyethylene cups that had not been cross-linked had the greatest wear. The worn areas had a burnished appearance and were clearly separated from the unworn region by a distinct ridge-line. The worn areas had lost all machine tracks, showed a large amount of UHMWPE 'flow', and long PE fibrils. The associated surface rippling was degraded. These features were considered synonymous with severe polyethylene wear. In contrast, the worn areas in the very cross-linked cups had a visibly matte surface and no ridge-line. Micro-examination showed that the machine tracks were still present. Ripple formations were less obvious than in the cups that were not cross-linked, polyethylene surface fibrils were scarcer and all the fibrils were much smaller than in the cups that were not crosslinked. Our two retrieved cups and the simulator cups confirmed the greater wear-resistance of very cross-linked polyethylene. It should also be noted that the SOM cup design and processing were unique and differed greatly from that of modern polyethylene cups.

  18. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    PubMed

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  19. Archaeological Investigation at El Dorado Lake, Butler County, Kansas. Phase III.

    DTIC Science & Technology

    1982-01-01

    time during which deep disturbance predominated is estimated to be roughly equal to the number of years surface and shallow techniques have been... during excavation, but sampled. Measurements are therefore estimated from scale drawings of feature plans. However, the drawing of Feature 3 consists... roasting features with the limestones and/or deposited as refuse during separate disposal episodes. Fauna and Flora A total of 862 bones and bone

  20. KSC-04PD-1319

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Sitting in front of the open hatch into Discovery, which is in the Orbiter Processing Facility, Mike Bolt (left), NASAs Jack Legere (center front) and Jay Feaster (right) display the Stanley Cup. Feaster is general manager of the Tampa Bay Lightning, who won the cup in 2004, and Bolt is keeper of the cup. Legere is NASA Quality Assurance specialist for the Shuttle Program. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. Feaster brought the cup to KSC while on a tour. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  1. Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

    PubMed Central

    Sanz-Andrés, Ángel; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  2. Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses. A randomized clinical RSA study with 2-year follow-up.

    PubMed

    Hansen, Torben Baek; Stilling, Maiken

    2013-02-01

    Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. In a prospective, parallel-group, randomized patient-blinded clinical trial, we included 32 hands in 28 patients (5 males) with a mean age of 58 (40-77) years and with Eaton stage-2 or -3 osteoarthritis of the trapeziometacarpal joint. Patients were randomized to surgery with a cemented DLC all-polyethylene cup (C) (n = 16) or an uncemented hydroxyapatite-coated chrome-cobalt Elektra screw cup (UC) (n = 16). Uncemented cups were inserted without threading of the bone. Stereoradiographs for evaluation of cup migration (primary effect size) and DASH and pain scores were obtained during 2 years of follow-up. The 2-year total translation (TT) was similar (p = 0.2): 0.24 mm (SD 0.10) for the C (n = 11) and 0.19 mm (SD 0.16) for the UC (n = 11). Variances were similar (p = 0.4). Judged by RSA, 2 UC cups and 1 C cup became loose (TT > 1 mm). Both UC cups were found to be loose at revision. Grip strength, pain, and DASH scores were similar between groups at all measurement points. Early implant fixation and clinical outcome were equally good with both cup designs. This is the first clinical RSA study on trapezium cups, and the method appears to be clinically useful for detection of loose implants.

  3. Multiple data sets and modelling choices in a comparative LCA of disposable beverage cups.

    PubMed

    van der Harst, Eugenie; Potting, José; Kroeze, Carolien

    2014-10-01

    This study used multiple data sets and modelling choices in an environmental life cycle assessment (LCA) to compare typical disposable beverage cups made from polystyrene (PS), polylactic acid (PLA; bioplastic) and paper lined with bioplastic (biopaper). Incineration and recycling were considered as waste processing options, and for the PLA and biopaper cup also composting and anaerobic digestion. Multiple data sets and modelling choices were systematically used to calculate average results and the spread in results for each disposable cup in eleven impact categories. The LCA results of all combinations of data sets and modelling choices consistently identify three processes that dominate the environmental impact: (1) production of the cup's basic material (PS, PLA, biopaper), (2) cup manufacturing, and (3) waste processing. The large spread in results for impact categories strongly overlaps among the cups, however, and therefore does not allow a preference for one type of cup material. Comparison of the individual waste treatment options suggests some cautious preferences. The average waste treatment results indicate that recycling is the preferred option for PLA cups, followed by anaerobic digestion and incineration. Recycling is slightly preferred over incineration for the biopaper cups. There is no preferred waste treatment option for the PS cups. Taking into account the spread in waste treatment results for all cups, however, none of these preferences for waste processing options can be justified. The only exception is composting, which is least preferred for both PLA and biopaper cups. Our study illustrates that using multiple data sets and modelling choices can lead to considerable spread in LCA results. This makes comparing products more complex, but the outcomes more robust. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Cupping in dermatology: a critical review and update.

    PubMed

    Soliman, Yssra; Hamed, Nouran; Khachemoune, Amor

    2018-06-01

    Cupping is an ancient procedure that has been practiced for thousands of years. It has been used to treat a variety of medical conditions, including dermatological ones. Cupping has been described in the literature for the treatment of conditions such as acne and eczema. The procedure is fundamentally divided into dry cupping and wet cupping; however, there have been many modern adaptations. Adverse events related to the procedure have been reported in the literature and should be considered by patients. However, cupping has a promising role in helping manage dermatological conditions.

  5. Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

    PubMed

    Schwarz, T; Weber, M; Wörner, M; Renkawitz, T; Grifka, J; Craiovan, B

    2017-05-01

    Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text] for inclination. This novel calculation for central beam offset correction enables highly accurate measurement of the cup position.

  6. Press-fit acetabular cup fixation: principles and testing.

    PubMed

    Macdonald, W; Carlsson, L V; Charnley, G J; Jacobsson, C M

    1999-01-01

    Pre-clinical testing of the fixation of press-fit acetabular components of total hip prostheses relies on cadaver or synthetic bone, but the properties and geometry of bone models differ from those of physiological bone. Cup designs use varied mechanisms for initial stability in bone; therefore, using different analogues and tests is appropriate. Press-fit cup stability was tested in the following: firstly, polyurethane (PU) foam modelling cancellous support; secondly, glass-fibre reinforced epoxide (GFRE) tubes modelling acetabular cortical support; thirdly, cadaveric acetabula. Three commercial cups [Harris-Galante II (H-G-II), Zimmer; Optifix, Smith & Nephew, Richards; porous coated anatomic (PCA), Howmedica] and an experimental cup with enhanced rim fixation were tested in three modes: direct pull-out, lever-out and axial torque. The fixation stabilities measured in the PU and the GFRE models showed trends consistent with those in cadaver bone, differing in the oversizing and cup geometry. The experimental cup was significantly more secure in most modes than other cups; the H-G II and Optifix cups showed similar stabilities, lower than that of the experimental cup but greater than that of the PCA cup (analysis of variance and Tukey's highly significant test; p < 0.001). The stabilities measured in cadaver bone more closely approximated those in GFRE. The use of several bone analogues enables separation of fixation mechanisms, allowing more accurate prediction of in vivo performance.

  7. The Simpsons: Public Choice in the Tradition of Swift and Orwell

    ERIC Educational Resources Information Center

    Considine, John

    2006-01-01

    The author disagrees with Homer Simpson who claims that "...cartoons don't have any deep meaning. They're just stupid drawings that give you a cheap laugh." He argues that The Simpsons have a deep meaning in the same way as the works of Jonathan Swift and George Orwell. The message in The Simpsons, Swift, and Orwell is that those in charge do not…

  8. Stability of Uncemented Cups - Long-Term Effect of Screws, Pegs and HA Coating: A 14-Year RSA Follow-Up of Total Hip Arthroplasty.

    PubMed

    Otten, Volker T C; Crnalic, Sead; Röhrl, Stephan M; Nivbrant, Bo; Nilsson, Kjell G

    2016-01-01

    Screws, pegs and hydroxyapatite-coating are used to enhance the primary stability of uncemented cups. We present a 14-year follow-up of 48 hips randomized to four groups: press-fit only, press-fit plus screws, press-fit plus pegs and hydroxyapatite-coated cups. Radiostereometric migration measurements showed equally good stability regardless cup augmentation. The mean wear rate was high, 0.21 mm/year, with no differences between the groups. Seven hips had radiographical osteolysis but only in hips with augmented cups. Cups without screw-holes compared with cups with screw-holes resulted in better clinical outcome at the 14-year follow-up. Thus, augmentation of uncemented cups with screws, pegs, or hydroxyapatite did not appear to improve the long-term stability compared with press-fit only. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Dispersal of seeds from splash-cup plants

    NASA Astrophysics Data System (ADS)

    Pepper, Rachel

    2017-11-01

    Splash cup plants disperse their seeds with the help of raindrops. The seeds sit in a small (mm-scale) conical cup and are ejected upon drop impact. The seeds are ejected at velocities up to five times the impact speed of the raindrop, and are dispersed up to 1 m away from the parent plant, which is only a few cm high. Previous work investigating the mechanism of this remarkable dispersal predicted an optimum cup opening angle of around 40°, which matched reasonably well with experiments performed with 3D-printed splash cup models. Those experiments were done with off-center drop impacts on initially empty cups with no seeds. We discuss similar experiments for cups that are not initially empty, but rather contain seed mimics, water, or both seeds and water. For some of these realistic initial states results are strikingly different from empty cups. Connections to theory will also be discussed.

  10. Clinical research evidence of cupping therapy in China: a systematic literature review

    PubMed Central

    2010-01-01

    Background Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it. This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. Methods We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. Results 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs), 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. Conclusions According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice. PMID:21078197

  11. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review.

    PubMed

    Snijders, Thom E; Willemsen, Koen; van Gaalen, Steven M; Castelein, Rene M; Weinans, Harrie; de Gast, Arthur

    2018-05-01

    Dislocation is one of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. Twenty eight relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.

  12. Effect of palady and cup feeding on premature neonates' weight gain and reaching full oral feeding time interval.

    PubMed

    Marofi, Maryam; Abedini, Fatemeh; Mohammadizadeh, Majid; Talakoub, Sedigheh

    2016-01-01

    Premature neonates' feeding is of great importance due to its effective role in their growth. These neonates should reach an independent oral nutrition stage before being discharged from the Neonatal Intensive care Unit. Therefore, the researcher decided to conduct a study on the effect of palady and cup feeding on premature neonates' weight gain and their reaching full oral feeding time interval. This is a clinical trial with a quantitative design conducted on 69 premature infants (gestational age between 29 and 32 weeks) who were assigned to cup (n = 34) and palady (n = 35) feeding groups through random allocation. The first feeding was administrated either by cup or palady method in each shift within seven sequential days (total of 21 cup and palady feedings). Then, the rest of feeding was administrated by gavage. Mean hospitalization time (cup = 39.01 and palady = 30.4; P < 0.001) and mean time interval to reach full oral feeding (cup = 33.7 and palady = 24.1; P < 0.001) were significantly lower in palady group compared to cup group. Mean weight changes of neonates 7 weeks after the intervention compared to those in the beginning of the intervention were significantly more in palady group compared to the cup group (cup = 146.7 and palady = 198.8; P < 0.001). The neonates in palady group reached full oral feeding earlier than those of cup group. Subjects' weight gain was also higher in palady group compared to the cup group. Premature neonates with over 30 weeks of gestational age and physiological stability can be fed by palady.

  13. The efficacy of a “double-D-shaped” wire marker for radiographic measurement of acetabular cup orientation and wear

    PubMed Central

    Derbyshire, Brian; Raut, Videshnandan V.

    2013-01-01

    Historically, wire markers were attached to cemented all-plastic acetabular cups to demarcate the periphery and to measure socket wear. The wire shape was either a semi-circle passing over the pole of the cup, or a circle around the cup equator. More recently, “double-D” shaped markers were introduced with a part-circular aspect passing over the pole and a semi-circular aspect parallel to the equatorial plane. This configuration enabled cup retroversion to be distinguished from anteversion. In this study, the accuracy of radiographic measurement of cup orientation and wear was assessed for cups with “double-D” and circular markers. Each cup was attached to a measurement jig which could vary the anteversion/retroversion and internal/external rotation of the cup. A metal femoral head was fixed within the socket and radiographic images were created for all combinations of cup orientation settings. The images were measured using software with automatic edge detection, and cup orientation and zero-wear accuracies were determined for each setting. The median error for cup version measurements was similar for both types of wire marker (0.2° double-D marker, −0.24° circular marker), but measurements of the circular marker were more repeatable. The median inclination errors were 2.05° (double-D marker) and 0.23° (circular marker). The median overall “zero wear” errors were 0.19 mm (double-D marker) and 0.03 mm (circular marker). Measurements of the circular wire marker were much more repeatable. PMID:23813165

  14. Degenerative effects in rat eyes after experimental ocular hypertension.

    PubMed

    Scarsella, G; Nebbioso, M; Stefanini, S; Pescosolido, N

    2012-10-08

    This study was used to evaluate the degenerative effects on the retina and eye-cup sections after experimental induction of acute ocular hypertension on animal models. In particular, vascular events were directly focused in this research in order to assess the vascular remodeling after transient ocular hypertension on rat models. After local anaesthesia by administration of eye drops of 0.4% oxibuprocaine, 16 male adult Wistar rats were injected in the anterior chamber of the right eye with 15 µL of methylcellulose (MTC) 2% in physiological solution. The morphology and the vessels of the retina and eye-cup sections were examined in animals sacrificed 72 h after induction of ocular hypertension. In retinal fluorescein angiographies (FAGs), by means of fluorescein isothiocyanate-coniugated dextran (FITC), the radial venules showed enlargements and increased branching, while the arterioles appeared focally thickened. The length and size of actually perfused vessels appeared increased in the whole superficial plexus. In eye-cup sections of MTC-injected animals, in deep plexus and connecting layer there was a bigger increase of vessels than in controls. Moreover, the immunolocalization of astrocytic marker glial fibrillary acidic protein (GFAP) revealed its increased expression in internal limiting membrane and ganglion cell layer, as well as its presence in Müller cells. Finally, the pro-angiogenic factor vascular endothelial growth factor (VEGF) was found to be especially expressed by neurones of ganglion cell layer, both in control and in MTC-injected eyes. The data obtained in this experimental model on the interactions among glia, vessels and neurons should be useful to evaluate if also in glaucomatous patients the activation of vessel-adjacent glial cells might play key roles in following neuronal dysfunction.

  15. Migration of the Duraloc cup after 5 years.

    PubMed

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard

    2008-12-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).

  16. A level set method for cupping artifact correction in cone-beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Shipeng; Li, Haibo; Ge, Qi

    2015-08-15

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts inmore » CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts.« less

  17. Welding torch gas cup extension

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S. (Inventor)

    1988-01-01

    The invention relates to a gas shielded electric arc welding torch having a detachable gas cup extension which may be of any desired configuration or length. The gas cup extension assembly is mounted on a standard electric welding torch gas cup to enable welding in areas with limited access. The gas cup assembly has an upper tubular insert that fits within the gas cup such that its lower portion protrudes thereform and has a lower tubular extension that is screwed into the lower portion. The extension has a rim to define the outer perimeter of the seat edge about its entrance opening so a gasket may be placed to effect an airtight seal between the gas cup and extension. The tubular extension may be made of metal or cermaic material that can be machined. The novelty lies in the use of an extension assembly for a standard gas cup of an electric arc welding torch which extension assembly is detachable permitting the use of a number of extensions which may be of different configurations and materials and yet fit the standard gas cup.

  18. Soft drink, software and softening of teeth - a case report of tooth wear in the mixed dentition due to a combination of dental erosion and attrition.

    PubMed

    Gambon, D L; Brand, H S; Nieuw Amerongen, A V

    2010-10-21

    This case report describes a 9-year-old boy with severe tooth wear as a result of drinking a single glass of soft drink per day. This soft drink was consumed over a period of one to two hours, while he was gaming intensively on his computer. As a result, a deep bite, enamel cupping, sensitivity of primary teeth and loss of fillings occurred. Therefore, dentists should be aware that in patients who are gaming intensively, the erosive potential of soft drinks can be potentiated by mechanical forces leading to excessive tooth wear.

  19. Early loosening of a press-fit cup with ceramic-on-ceramic articulation: our early results.

    PubMed

    Haverkamp, Daniël; Westerbos, Stijn; Campo, Martin M; Boonstra, Ritsert H; Rob Albers, G H; van der Vis, Harm M

    2013-12-01

    In this study, we present the short-term results of the Selexys TH+ cup with the Ceramys inlay which is a press-fit cup with a ceramic-on-ceramic articulation. (Mathys, Bettlach, Switzerland). We compared the results with a retrospective-matched control group with a Delta PF cup (Lima, Udine, Italy), which is also a press-fit cup with a ceramic-on-ceramic articulation. 257 elective hip arthroplasties with the Selexys TH+ cup in 250 patients placed in 2009 and 2010 were analyzed and compared with a control group retrospective analysis of the uncemented Delta PF cup (Lima, Udine, Italy) placed in 2007 and 2008 in 208 patients (222 hips). Surgical technique and surgeons were identical in both groups. During a follow-up period of 3-21 months, 19 aseptic loosenings (7.4 %) were found for the Selexys TH+ cup. The survival plotted by a Kaplan-Meier curve shows a 1-year survival of 87.4 %. The Lima Delta PF cup showed a 1-year survival of 99.5 %. Failure analysis showed no clear explanation for this early loosening. The Selexys TH+ cup combined with the Ceramys ceramic-on-ceramic inlay coupling show an unacceptable high early revision rate. Therefore, we advice against using this combination.

  20. Lean blowout limits of a gas turbine combustor operated with aviation fuel and methane

    NASA Astrophysics Data System (ADS)

    Xiao, Wei; Huang, Yong

    2016-05-01

    Lean blowout (LBO) limits is critical to the operational performance of combustion systems in propulsion and power generation. The swirl cup plays an important role in flame stability and has been widely used in aviation engines. Therefore, the effects of swirl cup geometry and flow dynamics on LBO limits are significant. An experiment was conducted for studying the lean blowout limits of a single dome rectangular model combustor with swirl cups. Three types of swirl cup (dual-axial swirl cup, axial-radial swirl cup, dual-radial swirl cup) were employed in the experiment which was operated with aviation fuel (Jet A-1) and methane under the idle condition. Experimental results showed that, with using both Jet A-1 and methane, the LBO limits increase with the air flow of primary swirler for dual-radial swirl cup, while LBO limits decrease with the air flow of primary swirler for dual-axial swirl cup. In addition, LBO limits increase with the swirl intensity for three swirl cups. The experimental results also showed that the flow dynamics instead of atomization poses a significant influence on LBO limits. An improved semi-empirical correlation of experimental data was derived to predict the LBO limits for gas turbine combustors.

  1. Pulsatile dry cupping in chronic low back pain - a randomized three-armed controlled clinical trial.

    PubMed

    Teut, M; Ullmann, A; Ortiz, M; Rotter, G; Binting, S; Cree, M; Lotz, F; Roll, S; Brinkhaus, B

    2018-04-02

    We aimed to investigate the effectiveness of two different forms of dry pulsatile cupping in patients with chronic low back pain (cLBP) compared to medication on demand only in a three-armed randomized trial. 110 cLBP patients were randomized to regular pulsatile cupping with 8 treatments plus paracetamol on demand (n = 37), minimal cupping with 8 treatments plus paracetamol on demand (n = 36) or the control group with paracetamol on demand only (n = 37). Primary outcome was the pain intensity on a visual analogue scale (VAS, 0-100 mm) after 4 weeks, secondary outcome parameter included VAS pain intensity after 12 weeks, back function as measured with the 'Funktionsfragebogen Hannover Rücken' (FFbH-R) and health related quality of life questionnaire Short form 36 (SF-36) after 4 and 12 weeks. The mean baseline-adjusted VAS after 4 weeks was 34.9 mm (95% CI: 28.7; 41.2) for pulsatile cupping, 40.4 (34.2; 46.7) for minimal cupping and 56.1 (49.8; 62.4) for control group, resulting in statistically significant differences between pulsatile cupping vs. control (21.2 (12.2; 30.1); p < 0.001) and minimal cupping vs. control (15.7 (6.9; 24.4); p = 0.001). After 12 weeks, mean adjusted VAS difference between pulsatile cupping vs. control was 15.1 ((3.1; 27.1); p = 0.014), and between minimal cupping vs. control 11.5 ((- 0.44; 23.4); p = 0.059). Differences of VAS between pulsatile cupping and minimal cupping showed no significant differences after 4 or 12 weeks. Pulsatile cupping was also better (- 5.8 (- 11.5;-0.1); p = 0.045) compared to control for back function after 4 weeks, but not after 12 weeks (- 5.4 (- 11.7;0.8); p = 0.088), pulsatile cupping also showed better improvements on SF-36 physical component scale compared to control at 4 and 12 weeks (- 5.6 (- 9.3;-2.0); p = 0.003; - 6.1 (- 9.9;-2.4); p = 0.002). For back function and quality of life minimal cupping group was not statistically different to control after 4 and 12 weeks. Paracetamol intake did not differ between the groups (cupping vs. control (7.3 (- 0.4;15.0); p = 0.063); minimal cupping vs. control (6.3 (- 2.0;14.5); p = 0.133). Both forms of cupping were effective in cLBP without showing significant differences in direct comparison after four weeks, only pulsatile cupping showed effects compared to control after 12 weeks. The study was registered at ClinicalTrials.gov (identifier: NCT02090686 ).

  2. Changes in dive behavior during naval sonar exposure in killer whales, long-finned pilot whales, and sperm whales.

    PubMed

    Sivle, L D; Kvadsheim, P H; Fahlman, A; Lam, F P A; Tyack, P L; Miller, P J O

    2012-01-01

    Anthropogenic underwater sound in the environment might potentially affect the behavior of marine mammals enough to have an impact on their reproduction and survival. Diving behavior of four killer whales (Orcinus orca), seven long-finned pilot whales (Globicephala melas), and four sperm whales (Physeter macrocephalus) was studied during controlled exposures to naval sonar [low frequency active sonar (LFAS): 1-2 kHz and mid frequency active sonar (MFAS): 6-7 kHz] during three field seasons (2006-2009). Diving behavior was monitored before, during and after sonar exposure using an archival tag placed on the animal with suction cups. The tag recorded the animal's vertical movement, and additional data on horizontal movement and vocalizations were used to determine behavioral modes. Killer whales that were conducting deep dives at sonar onset changed abruptly to shallow diving (ShD) during LFAS, while killer whales conducting deep dives at the onset of MFAS did not alter dive mode. When in ShD mode at sonar onset, killer whales did not change their diving behavior. Pilot and sperm whales performed normal deep dives (NDD) during MFAS exposure. During LFAS exposures, long-finned pilot whales mostly performed fewer deep dives and some sperm whales performed shallower and shorter dives. Acoustic recording data presented previously indicates that deep diving (DD) is associated with feeding. Therefore, the observed changes in dive behavior of the three species could potentially reduce the foraging efficiency of the affected animals.

  3. Changes in dive behavior during naval sonar exposure in killer whales, long-finned pilot whales, and sperm whales

    PubMed Central

    Sivle, L. D.; Kvadsheim, P. H.; Fahlman, A.; Lam, F. P. A.; Tyack, P. L.; Miller, P. J. O.

    2012-01-01

    Anthropogenic underwater sound in the environment might potentially affect the behavior of marine mammals enough to have an impact on their reproduction and survival. Diving behavior of four killer whales (Orcinus orca), seven long-finned pilot whales (Globicephala melas), and four sperm whales (Physeter macrocephalus) was studied during controlled exposures to naval sonar [low frequency active sonar (LFAS): 1–2 kHz and mid frequency active sonar (MFAS): 6–7 kHz] during three field seasons (2006–2009). Diving behavior was monitored before, during and after sonar exposure using an archival tag placed on the animal with suction cups. The tag recorded the animal's vertical movement, and additional data on horizontal movement and vocalizations were used to determine behavioral modes. Killer whales that were conducting deep dives at sonar onset changed abruptly to shallow diving (ShD) during LFAS, while killer whales conducting deep dives at the onset of MFAS did not alter dive mode. When in ShD mode at sonar onset, killer whales did not change their diving behavior. Pilot and sperm whales performed normal deep dives (NDD) during MFAS exposure. During LFAS exposures, long-finned pilot whales mostly performed fewer deep dives and some sperm whales performed shallower and shorter dives. Acoustic recording data presented previously indicates that deep diving (DD) is associated with feeding. Therefore, the observed changes in dive behavior of the three species could potentially reduce the foraging efficiency of the affected animals. PMID:23087648

  4. Wet-cupping removes oxidants and decreases oxidative stress.

    PubMed

    Tagil, Suleyman Murat; Celik, Huseyin Tugrul; Ciftci, Sefa; Kazanci, Fatmanur Hacievliyagil; Arslan, Muzeyyen; Erdamar, Nazan; Kesik, Yunus; Erdamar, Husamettin; Dane, Senol

    2014-12-01

    Wet-cupping therapy is one of the oldest known medical techniques. Although it is widely used in various conditions such as acute\\chronic inflammation, infectious diseases, and immune system disorders, its mechanism of action is not fully known. In this study, we investigated the oxidative status as the first step to elucidate possible mechanisms of action of wet cupping. Wet cupping therapy is implemented to 31 healthy volunteers. Venous blood samples and Wet cupping blood samples were taken concurrently. Serum nitricoxide, malondialdehyde levels and activity of superoxide dismutase and myeloperoxidase were measured spectrophotometrically. Wet cupping blood had higher activity of myeloperoxidase, lower activity of superoxide dismutase, higher levels of malondialdehyde and nitricoxide compared to the venous blood. Wet cupping removes oxidants and decreases oxidative stress. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit cups and UHMWPE liners: a finite element analysis.

    PubMed

    Goebel, Paul; Kluess, Daniel; Wieding, Jan; Souffrant, Robert; Heyer, Horst; Sander, Manuela; Bader, Rainer

    2013-03-01

    To increase the range of motion of total hip endoprostheses, prosthetic heads need to be enlarged, which implies that the cup and/or liner thickness must decrease. This may have negative effects on the wear rate, because the acetabular cups and liners could deform during press-fit implantation and hip joint loading. We compared the metal cup and polyethylene liner deformations that occurred when different wall thicknesses were used in order to evaluate the resulting changes in the clearance of the articulating region. A parametric finite element model utilized three cup and liner wall thicknesses to analyze cup and liner deformations after press-fit implantation into the pelvic bone. The resultant hip joint force during heel strike was applied while the femur was fixed, accounting for physiological muscle forces. The deformation behavior of the liner under joint loading was therefore assessed as a function of the head diameter and the resulting clearance. Press-fit implantation showed diametral cup deformations of 0.096, 0.034, and 0.014 mm for cup wall thicknesses of 3, 5, and 7 mm, respectively. The largest deformations (average 0.084 ± 0.003 mm) of liners with thicknesses of 4, 6, and 8 mm occurred with the smallest cup wall thickness (3 mm). The smallest liner deformation (0.011 mm) was obtained with largest cup and liner wall thicknesses. Under joint loading, liner deformations in thin-walled acetabular cups (3 mm) reduced the initial clearance by about 50 %. Acetabular press-fit cups with wall thicknesses of ≤5 mm should only be used in combination with polyethylene liners >6 mm thick in order to minimize the reduction in clearance.

  6. Radiographic cup anteversion measurement corrected from pelvic tilt.

    PubMed

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P < 0.001). The mean of 90 slopes and y-intercepts of the regression lines were -0.8 and -2.5°, which were applied as the general correction parameters for the proposed tool to correct conventional cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    PubMed

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Comparison of optic disc topography in non-glaucomatous eyes of children with juvenile diabetes mellitus and normal children.

    PubMed

    Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen

    2010-01-01

    To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.

  9. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    PubMed

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p < 0.05). Early construct migration occurred in 4 patients, with stabilization prior to 2-year follow-up in all but 1 patient. Incomplete, zone-3, nonprogressive acetabular radiolucencies were observed in 2 (7%) of the full cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  10. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup

    PubMed Central

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described. PMID:26361491

  11. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup.

    PubMed

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described.

  12. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    PubMed

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Migration of the Duraloc cup after 5 years

    PubMed Central

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter

    2007-01-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters ≥54 mm migrated significantly more than cups <54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%). PMID:17609953

  14. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  15. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing agents during prophylaxis (cleaning). The dental handpiece spins the rubber cup holding the polishing...

  16. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing agents during prophylaxis (cleaning). The dental handpiece spins the rubber cup holding the polishing...

  17. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing agents during prophylaxis (cleaning). The dental handpiece spins the rubber cup holding the polishing...

  18. Cup Stacking: Does It Deserve a Place in Physical Education Curricula?

    ERIC Educational Resources Information Center

    Udermann, Brian E.; Murray, Steven R.

    2006-01-01

    Cup stacking has become commonplace in today's physical education nomenclature. Proponents make claims that cup stacking improves cognitive, affective, and psychomotor abilities. At physical education conferences, scores of professional physical educators eagerly watch cup stacking representatives construct and deconstruct a variety of pyramids…

  19. KSC-04PD-1317

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. In the Orbiter Processing Facility, Jay Feaster, general manager of the National Hockey League 2004 Champions Tampa Bay Lightning, displays the Stanley Cup. At right is KSC Deputy Director Woodrow Whitlow. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. Feaster brought the cup to KSC while on a tour. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  20. Exploring volumetrically indexed cups

    NASA Astrophysics Data System (ADS)

    Jones, Dustin L.

    2011-03-01

    This article was inspired by a set of 12 cylindrical cups, which are volumetrically indexed; that is to say, the volume of cup n is equal to n times the volume of cup 1. Various sets of volumetrically indexed cylindrical cups are explored. I demonstrate how this children's toy is ripe for mathematical investigation, with connections to geometry, algebra and differential calculus. Students with an understanding of these topics should be able to complete the analysis and related exercises contained herein.

  1. Sample rotating turntable kit for infrared spectrometers

    DOEpatents

    Eckels, Joel Del [Livermore, CA; Klunder, Gregory L [Oakland, CA

    2008-03-04

    An infrared spectrometer sample rotating turntable kit has a rotatable sample cup containing the sample. The infrared spectrometer has an infrared spectrometer probe for analyzing the sample and the rotatable sample cup is adapted to receive the infrared spectrometer probe. A reflectance standard is located in the rotatable sample cup. A sleeve is positioned proximate the sample cup and adapted to receive the probe. A rotator rotates the rotatable sample cup. A battery is connected to the rotator.

  2. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial

    PubMed Central

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-01-01

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain sensitivity, satisfaction and safety at day 18 and 6 months. Altogether 141 patients were included in this study (139 females, 55.8 ± 9.1 years). After 18 days patients reported significant less pain after cupping compared to usual care (difference −12.4; 95% CI: −18.9; −5.9, p < 0.001) but not compared to sham (difference −3.0; 95% CI: −9.9, 3.9, p = 0.396). Further effects were found for quality of life compared to usual care. Patients were mildly satisfied with cupping and sham cupping; and only minor side effects were observed. Despite cupping therapy being more effective than usual care to improve pain intensity and quality of life, effects of cupping therapy were small and comparable to those of a sham treatment, and as such cupping cannot be recommended for fibromyalgia at the current time. PMID:27853272

  3. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial.

    PubMed

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-11-17

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain sensitivity, satisfaction and safety at day 18 and 6 months. Altogether 141 patients were included in this study (139 females, 55.8 ± 9.1 years). After 18 days patients reported significant less pain after cupping compared to usual care (difference -12.4; 95% CI: -18.9; -5.9, p < 0.001) but not compared to sham (difference -3.0; 95% CI: -9.9, 3.9, p = 0.396). Further effects were found for quality of life compared to usual care. Patients were mildly satisfied with cupping and sham cupping; and only minor side effects were observed. Despite cupping therapy being more effective than usual care to improve pain intensity and quality of life, effects of cupping therapy were small and comparable to those of a sham treatment, and as such cupping cannot be recommended for fibromyalgia at the current time.

  4. Dual-water mixture fuel burner

    DOEpatents

    Brown, Thomas D.; Reehl, Douglas P.; Walbert, Gary F.

    1986-08-05

    A coal-water mixture (CWM) burner includes a conically shaped rotating cup into which fuel comprised of coal particles suspended in a slurry is introduced via a first, elongated inner tube coupled to a narrow first end portion of the cup. A second, elongated outer tube is coaxially positioned about the first tube and delivers steam to the narrow first end of the cup. The fuel delivery end of the inner first tube is provided with a helical slot on its lateral surface for directing the CWM onto the inner surface of the rotating cup in the form of a uniform, thin sheet which, under the influence of the cup's centrifugal force, flows toward a second, open, expanded end portion of the rotating cup positioned immediately adjacent to a combustion chamber. The steam delivered to the rotating cup wets its inner surface and inhibits the coal within the CWM from adhering to the rotating cup. A primary air source directs a high velocity air flow coaxially about the expanded discharge end of the rotating cup for applying a shear force to the CWM in atomizing the fuel mixture for improved combustion. A secondary air source directs secondary air into the combustion chamber adjacent to the outlet of the rotating cup at a desired pitch angle relative to the fuel mixture/steam flow to promote recirculation of hot combustion gases within the ignition zone for increased flame stability.

  5. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Gene Expression Profiling of the Intact Dermal Sheath Cup of Human Hair Follicles.

    PubMed

    Niiyama, Shiro; Ishimatsu-Tsuji, Yumiko; Nakazawa, Yosuke; Yoshida, Yuzo; Soma, Tsutomu; Ideta, Ritsuro; Mukai, Hideki; Kishimoto, Jiro

    2018-04-24

    Cells that constitute the dermal papillae of hair follicles might be derived from the dermal sheath, the peribulbar component of which is the dermal sheath cup. The dermal sheath cup is thought to include the progenitor cells of the dermal papillae and possesses hair inductive potential; however, it has not yet been well characterized. This study investigated the gene expression profile of the intact dermal sheath cup, and identified dermal sheath cup signature genes, including extracellular matrix components and BMP-binding molecules, as well as TGF-b1 as an upstream regulator. Among these, GREM2, a member of the BMP antagonists, was found by in situ hybridization to be highly specific to the dermal sheath cup, implying that GREM2 is a key molecule contributing to maintenance of the properties of the dermal sheath cup.

  7. Mode of action of cupping--local metabolism and pain thresholds in neck pain patients and healthy subjects.

    PubMed

    Emerich, M; Braeunig, M; Clement, H W; Lüdtke, R; Huber, R

    2014-02-01

    Cupping worldwide has been part of traditional medicine systems and is in the western world used as CAM therapy mainly for treating pain syndromes. The mode of action is up to now unclear. In order to investigate its mechanism we measured in parallel metabolic changes in the tissue under the cupping glass and pressure pain thresholds. In 12 volunteers (6 healthy subjects and 6 patients with chronic neck pain) a microdialysis system was implanted subcutaneously on both sides (left and right) above the trapezius muscle. After baseline measures cupping was performed at one randomly selected side (left or right), the other side served as control. Every 20 min during baseline measures and for 280 min after cupping, microdialysis probes for detection of lactate, pyruvate, glucose and glycerin were taken. In addition, pain thresholds were measured before and after cupping with algometry. Cupping resulted in a strong increase of lactate (beginning 160 min after cupping until the end of the measurements) and the lactate/pyruvate ratio, indicating an anaerobe metabolism in the surrounding tissue. Baseline pain thresholds were non-significantly lower in neck pain patients compared to healthy controls and slightly increased immediately after cupping (p<0.05 compared to baseline close to the area of cupping in healthy subjects and on the foot in neck pain patients). After 280 min no more significant changes of pain thresholds were detected. Cupping induces >280 min lasting anaerobe metabolism in the subcutaneous tissue and increases immediate pressure pain thresholds in some areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Germline genetics of cancer of unknown primary (CUP) and its specific subtypes.

    PubMed

    Hemminki, Kari; Chen, Bowang; Kumar, Abhishek; Melander, Olle; Manjer, Jonas; Hallmans, Göran; Pettersson-Kymmer, Ulrika; Ohlsson, Claes; Folprecht, Gunnar; Löffler, Harald; Krämer, Alwin; Försti, Asta

    2016-04-19

    Cancer of unknown primary site (CUP) is a fatal cancer diagnosed through metastases at various organs. Little is known about germline genetics of CUP which appears worth of a search in view of reported familial associations in CUP. In the present study, samples from CUP patients were identified from 2 Swedish biobanks and a German clinical trial, totaling 578 CUP patients and 7628 regionally matched controls. Diagnostic data specified the organ where metastases were diagnosed. We carried out a genome-wide association study on CUP cases and controls. In the whole sample set, 6 loci reached an allelic p-value in the range of 10-7 and were supported by data from the three centers. Three associations were located next to non-coding RNA genes. rs2660852 flanked 5'UTR of LTA4H (leukotriene A4 hydrolase), rs477145 was intronic to TIAM1 (T-cell lymphoma invasion and metastases) and rs2835931 was intronic to KCNJ6 (potassium channel, inwardly rectifying subfamily J, member 6). In analysis of subgroups of CUP patients (smokers, non-smokers and CUP with liver metastases) genome-wide significant associations were noted. For patients with liver metastases associations on chromosome 6 and 11, the latter including a cluster of genes DHCR7 and NADSYN1, encoding key enzymes in cholesterol and NAD synthesis, and KRTAP5-7, encoding a keratin associated protein. This first GWAS on CUP provide preliminary evidence that germline genes relating to inflammation (LTA4H), metastatic promotion (TIAM1) in association with lipid metabolic disturbance (chromosome 11 cluster) may contribute to the risk of CUP.

  9. Factors influencing initial cup stability in total hip arthroplasty.

    PubMed

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Mechanical Behaviour of Conventional Materials at Experimental Conditions of Deep Drawing Technological Process

    NASA Astrophysics Data System (ADS)

    Nikolov, N.; Pashkouleva, D.; Kavardzhikov, V.

    2012-09-01

    The paper deals with experimental investigations on the mechanical behaviour of body-centred-cubic (BCC) and face-centred-cubic (FCC)-conventionally structured sheet metalic-metalic materials under stress-strain conditions of a deep drawing process determined by a coefficient close to the limiting one for Steel 08 and punch diameter of 50 mm. The mechanical characteristics of the investigated materials are identified by one-dimensional tension tests. The materials' responses, as results of identical loading conditions, are described by the change of blank sizes and characteristics of the forming processes. The chosen deformation path ensures obtaining a qualitative steel piece and leads to failures of aluminium and brass blanks. The reported results could be useful for investigations and predictions of the mechanical responses of such type metallic structures applying microscopic instrumented observations and numerical simulations.

  11. 29 CFR 1910.241 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reinforced does not cover wheels using such mechanical additions as steel rings, steel cup backs or wire or tape winding. (8) Type 11 flaring cup wheels. Type 11 flaring cup wheels have double diameter... mounting listed for Type 6 straight sided cup wheels definition in subparagraph (9) of this paragraph. Type...

  12. 77 FR 20846 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items and Packaging Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-835] Certain Food Containers, Cups, Plates... the sale within the United States after importation of certain food containers, cups, plates, cutlery... importation, or the sale within the United States after importation of certain food containers, cups, plates...

  13. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  14. 29 CFR 1910.241 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reinforced does not cover wheels using such mechanical additions as steel rings, steel cup backs or wire or tape winding. (8) Type 11 flaring cup wheels. Type 11 flaring cup wheels have double diameter... mounting listed for Type 6 straight sided cup wheels definition in subparagraph (9) of this paragraph. Type...

  15. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  16. 77 FR 14423 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof; Notice...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... INTERNATIONAL TRADE COMMISSION [DN 2883] Certain Food Containers, Cups, Plates, Cutlery, and... Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof, DN 2883; the Commission is... importation of certain food containers, cups, plates, cutlery, and related items, and packaging thereof. The...

  17. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and... OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5400 Menstrual cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  18. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and... OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5400 Menstrual cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  19. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and... OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5400 Menstrual cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  20. Deep level transient spectroscopy (DLTS) on colloidal-synthesized nanocrystal solids.

    PubMed

    Bozyigit, Deniz; Jakob, Michael; Yarema, Olesya; Wood, Vanessa

    2013-04-24

    We demonstrate current-based, deep level transient spectroscopy (DLTS) on semiconductor nanocrystal solids to obtain quantitative information on deep-lying trap states, which play an important role in the electronic transport properties of these novel solids and impact optoelectronic device performance. Here, we apply this purely electrical measurement to an ethanedithiol-treated, PbS nanocrystal solid and find a deep trap with an activation energy of 0.40 eV and a density of NT = 1.7 × 10(17) cm(-3). We use these findings to draw and interpret band structure models to gain insight into charge transport in PbS nanocrystal solids and the operation of PbS nanocrystal-based solar cells.

  1. KSC-04PD-1318

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. In the Orbiter Processing Facility, Jay Feaster, general manager of the National Hockey League 2004 Champions Tampa Bay Lightning, sits next to the Stanley Cup in front of the open hatch into Discovery. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. Feaster brought the cup to KSC while on a tour. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  2. KSC-04PD-1314

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Jay Feaster, general manager of the National Hockey League 2004 Champions Tampa Bay Lightning, stands next to the Stanley Cup, which he brought to KSC while on a tour. The cup stands next to the orbiter Discovery in the Orbiter Processing Facility. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  3. KSC-04PD-1315

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Jack Legere, NASA Quality Assurance specialist for the Shuttle Program, displays the Stanley Cup to employees in the Orbiter Processing Facility. Behind him is Discovery. Jay Feaster, general manager of the National Hockey League 2004 Champions Tampa Bay Lightning, brought the cup to KSC while on a tour. The cup was also briefly available for viewing by employees in the KSC Training Auditorium. The Stanley Cup weighs 35 pounds and is more than 100 years old. The Lightning will be added to the cup in September.

  4. [Development of lipoma following a single cupping massage - a case report].

    PubMed

    Schumann, Stefan; Lauche, Romy; Hohmann, Claudia; Zirbes, Thomas; Dobos, Gustav; Saha, Felix Joyonto

    2012-01-01

    The cupping massage is a form of bloodless cupping. This type of cupping is particularly used to treat muscular tension and musculoskeletal pain, such as chronic neck pain; however the data records on mechanisms and potential side effects are not satisfactory. In a study on the effectiveness of cupping massage in patients with chronic neck pain, one patient showed a formation of a lipoma in the cupping area after the first treatment session. Because of the short time interval between therapy and development of the lipoma, a primary cause is not realistic. This adverse event has not been described in the literature before, and the present report describes the case in summary.

  5. Evaluation of Porcelain Cup Soil Water Samplers for Bacteriological Sampling1

    PubMed Central

    Dazzo, Frank B.; Rothwell, Donald F.

    1974-01-01

    The validity of obtaining soil water for fecal coliform analyses by porcelain cup soil water samplers was examined. Numbers from samples of manure slurry drawn through porcelain cups were reduced 100- to 10,000,000-fold compared to numbers obtained from the external manure slurry, and 65% of the cups yielded coliform-free samples. Fecal coliforms adsorbed to cups apparently were released, thus influencing the counts of subsequent samples. Fecal coliforms persisted in soil water samplers buried in soil and thus could significantly influence the coliform counts of water samples obtained a month later. These studies indicate that porcelain cup soil water samplers do not yield valid water samples for fecal coliform analyses. Images PMID:16349998

  6. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy.

    PubMed

    Li, Ting; Li, Yaoxian; Lin, Yu; Li, Kai

    2017-01-01

    Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO 2 ]), deoxy-hemoglobin ([Hb]), and blood volume in the course of cupping therapy over 13 volunteers on the infraspinatus muscle, where is usually applied for shoulder pains. Both a prominent drop in [Hb] and a significant elevation in [HbO 2 ] in the tissue surrounding the cupping site were observed during both cupping and post-treatment, manifesting the enhancement of oxygen uptake. This resulting promotion indicates potential positive therapeutic effect of cupping therapy in hemodynamics for facilitating muscular functions.

  7. Proteomic effects of wet cupping (Al-hijamah).

    PubMed

    Almaiman, Amer A

    2018-01-01

    Wet cupping (Al-hijamah) is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient's skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted.

  8. Paradoxical, Cupping-Induced Localized Psoriasis: A Koebner Phenomenon.

    PubMed

    Vender, Reid; Vender, Ronald

    2015-01-01

    Cupping therapy is a traditional Chinese medicine used to heal psoriasis. The Koebner phenomenon is the occurrence of psoriatic lesions at the site of cutaneous injury. To describe the first case of biopsy-proven cupping-induced localized psoriasis, an example of the Koebner phenomenon. The histopathology of the lesions is described. A brief review of the literature regarding cupping therapy and its efficacy are discussed. A 45-year-old Asian male presented himself to the dermatology clinic for further treatment of his psoriasis. Four unusually circular plaques on the lower back were discovered. Pathologic diagnosis revealed an early lesion of psoriasis. on further inquiry, the patient admitted to undergoing a recent "cupping" procedure in an attempt to cure his condition. The efficacy of cupping therapy is controversial, and psoriatic patients may develop localized psoriasis through koebnerization as a result of cupping therapy rather than achieve desirable therapeutic benefits. © 2014 Canadian Dermatology Association.

  9. Proteomic effects of wet cupping (Al-hijamah)

    PubMed Central

    Almaiman, Amer A.

    2018-01-01

    Wet cupping (Al-hijamah) is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient’s skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted. PMID:29332103

  10. Automated volumetric evaluation of stereoscopic disc photography

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S

    2010-01-01

    PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996

  11. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  12. 78 FR 24063 - Special Local Regulation; Hebda Cup Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-24

    ...-AA08 Special Local Regulation; Hebda Cup Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI..., during, and immediately after the Hebda Cup Rowing Regatta. This special local regulation will establish... this boat race. It is also unnecessary to solicit public comments because the Hebda Cup Rowing Regatta...

  13. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  14. 76 FR 39289 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ...-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI AGENCY: Coast Guard... immediately after the Detroit APBA Gold Cup boat race. This special local regulation will establish... entry found in 33 CFR 100.918, Detroit APBA Gold Cup, Detroit, MI. Currently, the regulations located at...

  15. 29 CFR 1910.211 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... having a diameter, thickness and wall—wheel is mounted on the diameter. (3) Type 6 straight cup wheels...—Type 6 Straight Cup Wheels EC27OC91.054 Type 6—Straight-cup Wheel Side grinding wheel having a diameter... describe this shape type. (4) Type 11 flaring cup wheels mean wheels having double diameter dimensions D...

  16. 75 FR 39448 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ...-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI AGENCY: Coast Guard... APBA Gold Cup. This special local regulation is necessary to protect spectators and vessels from the... Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI in the Federal Register (75 FR 21191). We...

  17. 76 FR 53051 - Safety Zone; ISAF Nations Cup Grand Final Fireworks Display, Sheboygan, WI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-25

    ...-AA00 Safety Zone; ISAF Nations Cup Grand Final Fireworks Display, Sheboygan, WI AGENCY: Coast Guard.... Background and Purpose The ISAF Nations Cup Grand Final fireworks are a City permitted fireworks display that.... 165.T09-0755 Safety Zone; ISAF Nations Cup Grand Final Fireworks Display, Sheboygan, Wisconsin. (a...

  18. 77 FR 73311 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-10

    ...-AA00; 1625-AA08 Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco... the 2013 America's Cup events. This document corrects those erroneous coordinates. DATES: Effective on... published a temporary final rule regulating the on-water activities associated with the ``Louis Vuitton Cup...

  19. 75 FR 21191 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-23

    ...-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI AGENCY: Coast Guard... the Detroit APBA Gold Cup. This special local regulation is necessary to protect spectators and... race in conjunction with the Detroit APBA Gold Cup. The powerboat race and associated testing will...

  20. 77 FR 25073 - Special Local Regulation; Hebda Cup Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ...-AA08 Special Local Regulation; Hebda Cup Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI..., during, and immediately after the Hebda Cup Rowing Regatta. This special local regulation will establish....35T09-0340 Special Local Regulation; Hebda Cup Rowing Regatta, Wyandotte, MI. (a) Regulated area. A...

  1. Calcium and Vitamin D: Important at Every Age

    MedlinePlus

    ... 100 Turnip greens, boiled, ½ cup 99 Broccoli, raw, 1 cup 90 Ice cream, vanilla, ½ cup 85 Soy or rice milk, fortified with calcium, 1 cup 80–500 (varies) Calcium Culprits Although a balanced diet aids calcium absorption, high levels of protein and sodium (salt) in the diet are thought ...

  2. Dummy Cup Helps Robot-Welder Programmers

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S.

    1990-01-01

    Dummy gas cup used on torch of robotic welder during programming and practice runs. Made of metal or plastic, dummy cup inexpensive and durable. Withstands bumps caused by programming errors, and is sized for special welding jobs within limited clearances. After robot satisfactorily programmed, replaced by ceramic cup of same dimensions for actual welding.

  3. 77 FR 7025 - Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ...-AA00 Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... the America's Cup World Series sailing vessel racing event. This safety zone is intended to safeguard... participants and spectators involved with the America's Cup World Series in the vicinity of Newport, RI...

  4. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ...-AA00 Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... navigable waters of the East Passage, Narragansett Bay, Rhode Island, during the America's Cup World Series... rulemaking (NPRM) entitled ``Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI...

  5. Investigation of turbine ventilator performance after added wind cup for room exhaust air applications

    NASA Astrophysics Data System (ADS)

    Harun, D.; Zulfadhli; Akhyar, H.

    2018-05-01

    The turbine ventilator is a wind turbine with a vertical axis that has a combined function of the wind turbine and a suction fan. In this study, the turbine ventilator modified by adding a wind cup on the top (cap) turbine ventilator. The purpose of this experiment is to investigated the effect of the addition of wind cup on the turbine ventilator. Turbine ventilator used is type v30 and wind cup with diameter 77 mm. The experiment was conducted using a triangular pentagon model space chamber which was cut off to place the ventilator turbine ventilation cup with a volume of 0.983 m3 (equivalent to 1 mm3). The results of this study indicate that at an average wind speed of 1.8 m/s, the rotation of the turbine produced without a wind cup is 60.6 rpm while with the addition of a wind cup in the turbine ventilator is 69 rpm. The average increase of rotation turbine after added win cup is 8.4 rpm and the efficiency improvement of turbine ventilator is 1.7 %.

  6. Segmentation of optic disc and optic cup in retinal fundus images using shape regression.

    PubMed

    Sedai, Suman; Roy, Pallab K; Mahapatra, Dwarikanath; Garnavi, Rahil

    2016-08-01

    Glaucoma is one of the leading cause of blindness. The manual examination of optic cup and disc is a standard procedure used for detecting glaucoma. This paper presents a fully automatic regression based method which accurately segments optic cup and disc in retinal colour fundus image. First, we roughly segment optic disc using circular hough transform. The approximated optic disc is then used to compute the initial optic disc and cup shapes. We propose a robust and efficient cascaded shape regression method which iteratively learns the final shape of the optic cup and disc from a given initial shape. Gradient boosted regression trees are employed to learn each regressor in the cascade. A novel data augmentation approach is proposed to improve the regressors performance by generating synthetic training data. The proposed optic cup and disc segmentation method is applied on an image set of 50 patients and demonstrate high segmentation accuracy for optic cup and disc with dice metric of 0.95 and 0.85 respectively. Comparative study shows that our proposed method outperforms state of the art optic cup and disc segmentation methods.

  7. The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.

    PubMed

    Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner

    2016-07-01

    The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Patient-derived orthotopic xenograft models for cancer of unknown primary precisely distinguish chemotherapy, and tumor-targeting S. typhimurium A1-R is superior to first-line chemotherapy.

    PubMed

    Miyake, Kentaro; Kiyuna, Tasuku; Miyake, Masuyo; Kawaguchi, Kei; Yoon, Sang Nam; Zhang, Zhiying; Igarashi, Kentaro; Razmjooei, Sahar; Wangsiricharoen, Sintawat; Murakami, Takashi; Li, Yunfeng; Nelson, Scott D; Russell, Tara A; Singh, Arun S; Hiroshima, Yukihiko; Momiyama, Masashi; Matsuyama, Ryusei; Chishima, Takashi; Singh, Shree Ram; Endo, Itaru; Eilber, Fritz C; Hoffman, Robert M

    2018-01-01

    Cancer of unknown primary (CUP) is a recalcitrant disease with poor prognosis because it lacks standard first-line therapy. CUP consists of diverse malignancy groups, making personalized precision therapy essential. The present study aimed to identify an effective therapy for a CUP patient using a patient-derived orthotopic xenograft (PDOX) model. This paper reports the usefulness of the PDOX model to precisely identify effective and ineffective chemotherapy and to compare the efficacy of S. typhimurium A1-R with first-line chemotherapy using the CUP PDOX model. The present study is the first to use a CUP PDOX model, which was able to precisely distinguish the chemotherapeutic course. We found that a carboplatinum (CAR)-based regimen was effective for this CUP patient. We also demonstrated that S. typhimurium A1-R was more effective against the CUP tumor than first-line chemotherapy. Our results indicate that S. typhimurium A1-R has clinical potential for CUP, a resistant disease that requires effective therapy.

  9. A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.

    PubMed

    Busch, Vincent J J F; Verschueren, Joost; Adang, Eddy M; Lie, Stein A; Havelin, Leif I; Schreurs, Berend W

    2016-01-01

    Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? We designed a decision model for a cost-utility analysis of a cemented cup with acetabular impaction bone grafting versus an uncemented cup, in terms of cost per quality-adjusted life year (QALY) for the young adult with acetabular bone deficiency, in need for a primary total hip arthroplasty. Outcome probabilities and effectiveness were derived from the Radboud University Nijmegen Medical Centre and the Norwegian Hip Register. Multiple sensitivity analyses were used to assess the contribution of the included variables in the model's outcome. Cemented cups with impaction bone grafting were more cost-effective compared to the uncemented option in terms of costs per QALY. A scenario suggesting equal primary survival rates of both cemented and uncemented cups still showed an effect gain of the cemented cup with impaction bone grafting, but at higher costs. Based on this model, the first choice of treatment of the acetabular bone deficient osteoarthritic hip in a young patient is reconstruction with impaction bone grafting and a cemented cup.

  10. Initial stability of a highly porous titanium cup in an acetabular bone defect model.

    PubMed

    Yoshimoto, Kensei; Nakashima, Yasuharu; Wakiyama, Miyo; Hara, Daisuke; Nakamura, Akihiro; Iwamoto, Mikio

    2018-04-12

    The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. The maximum torque of a highly porous titanium cup, with a pore size of 640 μm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects. Copyright © 2018. Published by Elsevier B.V.

  11. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

    PubMed

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-02-01

    Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41-78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ -1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2-10) years. Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were "at risk" (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the 10 cases were "at risk" in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3-48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually.

  12. The Ca2+/Calcineurin-Regulated cup Gene Family in Dictyostelium discoideum and Its Possible Involvement in Development

    PubMed Central

    Coukell, Barrie; Li, Yi; Moniakis, John; Cameron, Anne

    2004-01-01

    Changes in free intracellular Ca2+ are thought to regulate several major processes during Dictyostelium development, including cell aggregation and cell type-specific gene expression, but the mechanisms involved are unclear. To learn more about Ca2+ signaling and Ca2+ homeostasis in this organism, we used suppression subtractive hybridization to identify genes up-regulated by high extracellular Ca2+. Unexpectedly, many of the genes identified belong to a novel gene family (termed cup) with seven members. In vegetative cells, the cup genes were up-regulated by high Ca2+ but not by other ions or by heat, oxidative, or osmotic stress. cup induction by Ca2+ was blocked completely by inhibitors of calcineurin and protein synthesis. In developing cells, cup expression was high during aggregation and late development but low during the slug stage. This pattern correlates closely with reported levels of free intracellular Ca2+ during development. The cup gene products are highly homologous, acidic proteins possessing putative ricin domains. BLAST searches failed to reveal homologs in other organisms, but Western analyses suggested that Cup-like proteins might exist in certain other cellular slime mold species. Localization experiments indicated that Cup proteins are primarily cytoplasmic but become cell membrane-associated during Ca2+ stress and cell aggregation. When cup expression was down-regulated by antisense RNA, the cells failed to aggregate. However, this developmental block was overcome by partially up-regulating cup expression. Together, these results suggest that the Cup proteins in Dictyostelium might play an important role in stabilizing and/or regulating the cell membrane during Ca2+ stress and/or certain stages of development. PMID:14871937

  13. Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.

    PubMed

    Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho

    2017-12-01

    To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all P<0.001). The percentile rates of mean cup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; P<0.001) and mild-or-moderate glaucoma (-4.20±0.33 vs. -3.14±0.19; P<0.001); and conversely, in severe glaucoma, mean cup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; P<0.001). In early-to-moderate glaucoma, the cup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.

  14. Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma

    PubMed Central

    Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki

    2015-01-01

    Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580

  15. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if cups are oriented at more than 40° of abduction.

  16. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    PubMed

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for the clinical indication of the examined cementless cups in osteoporotic bone.

  17. Efficacy of a Pelvic Lateral Positioner With a Mechanical Cup Navigator Based on the Anatomical Pelvic Plane in Total Hip Arthroplasty.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Ohta, Yoichi; Minoda, Yukihide; Takaoka, Kunio; Nakamura, Hiroaki

    2017-12-01

    The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide. The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators. The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012). The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Melted Ice

    NASA Image and Video Library

    2009-06-24

    These drawings depict explanations for the source of intense heat that has been measured coming from Enceladus south polar region. These models predict that water could exist in a deep layer as an ocean or sea and also near the surface.

  19. Impact of the Parameter Identification of Plastic Potentials on the Finite Element Simulation of Sheet Metal Forming

    NASA Astrophysics Data System (ADS)

    Rabahallah, M.; Bouvier, S.; Balan, T.; Bacroix, B.; Teodosiu, C.

    2007-04-01

    In this work, an implicit, backward Euler time integration scheme is developed for an anisotropic, elastic-plastic model based on strain-rate potentials. The constitutive algorithm includes a sub-stepping procedure to deal with the strong nonlinearity of the plastic potentials when applied to FCC materials. The algorithm is implemented in the static implicit version of the Abaqus finite element code. Several recent plastic potentials have been implemented in this framework. The most accurate potentials require the identification of about twenty material parameters. Both mechanical tests and micromechanical simulations have been used for their identification, for a number of BCC and FCC materials. The impact of the identification procedure on the prediction of ears in cup drawing is investigated.

  20. 33 CFR 165.T11-0551 - Safety Zone; America's Cup Sailing Events.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Sailing Events. 165.T11-0551 Section 165.T11-0551 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... § 165.T11-0551 Safety Zone; America's Cup Sailing Events. (a) Definitions—(1) America's Cup Racing... 34th America's Cup sailing events. (2) Patrol Commander. As used in this section, “Patrol Commander” or...

  1. 78 FR 57482 - Safety Zone; America's Cup Aerobatic Box, San Francisco Bay, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ...-AA00 Safety Zone; America's Cup Aerobatic Box, San Francisco Bay, San Francisco, CA AGENCY: Coast Guard... America's Cup air shows. These safety zones are established to provide a clear area on the water for... announced by America's Cup Race Management. ADDRESSES: Documents mentioned in this preamble are part of...

  2. 77 FR 46285 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-03

    ...] Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA AGENCY: Coast... 2012 program calendar for the on-water activities associated with the ``2012 America's Cup World Series... waters of San Francisco Bay associated with the 34th America's Cup sailing events taking place adjacent...

  3. 46 CFR 30.10-27 - Flashpoint-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...

  4. 77 FR 50373 - Special Local Regulation and Safety Zone; America's Cup World Series Regattas, San Francisco Bay...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ...] RIN 1625-AA00; 1625-AA08 Special Local Regulation and Safety Zone; America's Cup World Series Regattas... Acronyms APA Administrative Procedure Act ACRM America's Cup Race Management DHS Department of Homeland... associated with the ``2012 America's Cup World Series'' regatta scheduled to occur August 21-26, 2012 (77 FR...

  5. 78 FR 39588 - Special Local Regulations; Revision of 2013 America's Cup Regulated Area, San Francisco Bay; San...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-02

    ...-AA08 Special Local Regulations; Revision of 2013 America's Cup Regulated Area, San Francisco Bay; San...: The Coast Guard is revising the regulated area for the 2013 America's Cup sailing events. Previously... final rule regulating the on-water activities associated with the ``Louis Vuitton Cup,'' ``Red Bull...

  6. 46 CFR 30.10-27 - Flashpoint-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...

  7. 77 FR 54815 - Safety Zone: America's Cup World Series Regattas, San Francisco Bay; San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ...-AA00 Safety Zone: America's Cup World Series Regattas, San Francisco Bay; San Francisco, CA AGENCY... the on-water activities associated with 2012 America's Cup World Series regattas scheduled for October..., the City of San Francisco plans to host two America's Cup World Series regattas as part of a circuit...

  8. Physiological and Subjective Responses to Wearing the A/P22P-9(V) helicopter Aircrewman Chemical, Biological Protection Ensemble

    DTIC Science & Technology

    1992-04-21

    information processing than someone still learning. As such, skilled responses are less susceptible to thermal stress decrements. Based on these test data...quantity you consume. Caffeine Coffee cups Tea ____ cups Soda cans Decaffeinated Coffee cups Tea _ _ cups Soda cans Alcoholic Beer 12 oz Wine 8 oz Liquor

  9. A Laboratory Study of the Effects of Diet and Bright Light Countermeasures to Jet Lag

    DTIC Science & Technology

    1990-03-01

    3) Dinner : 1 cup raw vegetables or 1/2 cup cooked vegetables (several vegetables were unlimited such as lettuce) 1 egg or ounce of cheese or meat...1 tbsp butter or margarine 1 fruit exchange* 1 bread or pasta exchange* 2 1/ 3 cups raw vegetables or 1 1/ 4 cups cooked 1/ 4 cup milk...Search and the Human Observer. Clare W and Sinclair MA (eds) . Taylor and Francis~ondon , ~ pp. 30-39. (18) Rechtschaffen A and Kales A. ~Manual of

  10. Cupping regulates local immunomodulation to activate neural-endocrine-immune worknet.

    PubMed

    Guo, Yang; Chen, Bo; Wang, Dong-Qiang; Li, Ming-Yue; Lim, Calista Hui-Min; Guo, Yi; Chen, Zelin

    2017-08-01

    Research on cupping therapy is lacking at home and abroad. However, cupping and acupuncture therapy are both surface stimulation therapies. This paper suggests the mechanism of cupping therapy and proposes that the same mechanism underlies both cupping and acupuncture therapy. The microenvironment is changed when stimulating the surface of the skin, and physical signals transform into biological signals, which also interact with each other in the body. These signalling cascades activate the neuroendocrine-immune system, which produces the therapeutic effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Anaemia and skin pigmentation after excessive cupping therapy by an unqualified therapist in Korea: a case report.

    PubMed

    Kim, Kun Hyung; Kim, Tae-Hun; Hwangbo, Min; Yang, Gi Young

    2012-09-01

    A case is reported of skin pigmentation and associated anemia resulting from persistently repeated cupping therapies performed by an unqualified practitioner in South Korea. Almost 30 sessions of excessive cupping therapies with blood loss over two months yielded little benefit but led the patient to admit a hospital and receive blood transfusion for acquired iron deficiency anemia. Skin pigmentation on the cupping-attached region remained without any subjective discomfort. We suggest the importance of qualified health professionals when receiving cupping treatments.

  12. Plastic cup traps equipped with light-emitting diodes for monitoring adult Bemisia tabaci (Homoptera: Aleyrodidae).

    PubMed

    Chu, Chang-Chi; Jackson, Charles G; Alexander, Patrick J; Karut, Kamil; Henneberry, Thomas J

    2003-06-01

    Equipping the standard plastic cup trap, also known as the CC trap, with lime-green light-emitting diodes (LED-plastic cup trap) increased its efficacy for catching Bemisia tabaci by 100%. Few Eretmocerus eremicus Rose and Zolnerowich and Encarsia formosa Gahan were caught in LED-plastic cup traps. The LED-plastic cup traps are less expensive than yellow sticky card traps for monitoring adult whiteflies in greenhouse crop production systems and are more compatible with whitefly parasitoids releases for Bemisia nymph control.

  13. [Clinical application of moving cupping therapy based on skin reaction observation and syndrome differentiation].

    PubMed

    Deng, Xiao-Lan; Chen, Bo; Chen, Ze-Lin

    2014-12-01

    The diagnostic evidence on clinical diseases and theoretic basis of moving cupping therapy were ex- plored in the paper. By the observation of the local reaction, such as skin appearance and color, the affected location, duration of sickness and nature of disease were judged. Different moving cupping methods were selected for different disorders. It was discovered that the property of syndromes should be recognized by the palpation on skin and muscle in the moving cupping therapy so that the pathogenesis and treating principle could be carefully determined. The moving cupping therapy is the important component of body surface therapy. Skin reaction observation and syndrome differentiation is the essential guidance of the moving cupping therapy.

  14. Soft Drink, Software and Softening of Teeth – a Case Report of Tooth Wear in the Mixed Dentition Due to a Combination of Dental Erosion and Attrition

    PubMed Central

    Gambon, D. L; Brand, H. S; Nieuw Amerongen, A.V

    2010-01-01

    This case report describes a 9-year-old boy with severe tooth wear as a result of drinking a single glass of soft drink per day. This soft drink was consumed over a period of one to two hours, while he was gaming intensively on his computer. As a result, a deep bite, enamel cupping, sensitivity of primary teeth and loss of fillings occurred. Therefore, dentists should be aware that in patients who are gaming intensively, the erosive potential of soft drinks can be potentiated by mechanical forces leading to excessive tooth wear. PMID:21243073

  15. Antifouling leaching technique for optical lenses

    USGS Publications Warehouse

    Strahle, William J.; Perez, C. L.; Martini, Marinna A.

    1994-01-01

    The effectiveness of optical lenses deployed in water less than 100 m deep is significantly reduced by biofouling caused by the settlement of macrofauna, such as barnacles, hydroids, and tunicates. However, machineable porous plastic rings can be used to dispense antifoulant into the water in front of the lens to retard macrofaunal growth without obstructing the light path. Unlike coatings which can degrade the optical performance, antifouling rings do not interfere with the instrument optics. The authors have designed plastic, reusable cup-like antifouling rings to slip over the optical lenses of a transmissometer. These rings have been used for several deployments on shallow moorings in Massachusetts Bay, MA and have increased the time before fouling degrades optical characteristics

  16. The effect of wet cupping on quality of life of adult patients with chronic medical conditions in King Abdulaziz University Hospital.

    PubMed

    Al Jaouni, Soad K; El-Fiky, Eman A; Mourad, Samiha A; Ibrahim, Nahla Khamis; Kaki, Abdullah M; Rohaiem, Sawsan M; Qari, Mohamad H; Tabsh, Laila M; Aljawhari, Adel A

    2017-01-01

    To assess the effect of wet cupping on health-related quality of life (HRQOL) of adult patients with chronic medical conditions, who were referred to the Cupping Clinic of King Abdulaziz University Hospital (KAUH), Jeddah, Kingdom of Saudi Arabia. Methods: A controlled, quasi-experimental study design was carried out among 629 patients referred for cupping from the KAUH Specialty Clinics, during the period from January to December 2014. Patients in the intervention group (309 patients) completed a pre-test included WHO quality of life-BREF, received one wet-cupping session, and filled-out the post-test (1 month later). Patients in the control group (320 patients) completed the pre-test during their enrollment in the study and post-test one month later. Both groups received their ordinary treatment. Descriptive and inferential statistics were performed.  Results: Pain was the most common cause for cupping referral. After cupping intervention, the mean scores of most of the HRQOL domains, especially the physical domain, improved significantly among patients in the intervention group. The mean total score of physical HRQOL domain was 61.6 ± 13.6 before cupping, and reached 69.7 ± 12.6 after intervention (paired t-test=11.3, p=0.000). Improvements in HRQOL were noticed for almost all types of pain and other medical conditions.  Conclusion: There are promising effects in favor of using wet cupping for improving HRQOL of patients with chronic conditions. Cupping is recommended as a complementary treatment modality for chronic medical conditions, especially pain.

  17. Feeding neonates by cup: A systematic review of the literature

    PubMed Central

    McKinney, Christy M.; Glass, Robin P.; Coffey, Patricia; Rue, Tessa; Vaughn, Matthew G.; Cunningham, Michael

    2016-01-01

    Objective WHO and UNICEF recommend cup feeding for neonates unable to breastfeed in low-resource settings. In developed countries, cup feeding in lieu of bottle feeding in the neonatal period is hypothesized to improve breastfeeding outcomes for those initially unable to breastfeed. Our aim was to synthesize the entire body of evidence on cup feeding. Methods We searched domestic and international databases for original research. Our search criteria required original data on cup feeding in neonates published in English between January 1990 and December 2014. Results We identified 28 original research papers. Ten were randomized clinical trials, 7 non-randomized intervention studies, and 11 observational studies; 11 were conducted in developing country. Outcomes evaluated included physiologic stability, safety, intake, duration, spillage, weight gain, any and exclusive breastfeeding, length of hospital stay, compliance, and acceptability. Cup feeding appears to be safe though intake may be less and spillage greater relative to bottle or tube feeding. Overall, slightly higher proportions of cup fed versus bottle fed infants report any breastfeeding; a greater proportion of cup fed infants reported exclusive breastfeeding at discharge and beyond. Cup feeding increases breastfeeding in subgroups (e.g. those who intend to breastfeed or women who had a Caesarean section). Compliance and acceptability is problematic in certain settings. Conclusions Further research on long-term breastfeeding outcomes and in low-resource settings would be helpful. Research data on high risk infants (e.g. those with cleft palates) would be informative. Innovative cup feeding approaches to minimize spillage, optimize compliance, and increase breastfeeding feeding are needed. PMID:27016350

  18. Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

    PubMed

    Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee

    2017-08-01

    Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.

  19. Impact of currently marketed tampons and menstrual cups on Staphylococcus aureus growth and TSST-1 production in vitro.

    PubMed

    Nonfoux, Louis; Chiaruzzi, Myriam; Badiou, Cédric; Baude, Jessica; Tristan, Anne; Thioulouse, Jean; Muller, Daniel; Prigent Combaret, Claire; Lina, Gérard

    2018-04-20

    Fifteen currently marketed intravaginal protection products (11 types of tampon and four menstrual cups) were tested by the modified tampon sac method to determine their effect on Staphylococcus aureus growth and toxic shock toxin 1 (TSST-1) production. Most tampons reduced S. aureus growth and TSST-1 production, with differences based on brand and composition, and S. aureus growth was higher in de-structured than in unaltered tampons. We observed higher S. aureus growth and toxin production in menstrual cups than in tampons, potentially due to the additional air introduced to the bag by cups, with differences based on cup composition and size. Importance Menstrual toxic shock syndrome is a rare but severe disease. It occurs in healthy women vaginally colonized by Staphylococcus aureus producing toxic shock syndrome toxin 1 using intravaginal protection such as tampons or menstrual cups. Intravaginal protection induces TSS production by collecting catamenial products which act as a growth medium for S. aureus Previous studies have evaluated the impact of tampon composition on S. aureus producing toxic shock syndrome toxin 1, but they are not recent and did not include menstrual cups. This study demonstrates that highly reproducible results for S. aureus growth and TSST-1 production can be obtained using a simple protocol that reproduces the physiological conditions of tampon and cup usage as closely as possible, providing recommendations for tampon or cup use to both manufacturers and consumers. Notably, our results do not show that menstrual cups are safer than tampons and suggest that they require similar precautions. Copyright © 2018 American Society for Microbiology.

  20. The effect of wet cupping on quality of life of adult patients with chronic medical conditions in King Abdulaziz University Hospital

    PubMed Central

    Jaouni, Soad K. Al; El-Fiky, Eman A.; Mourad, Samiha A.; Ibrahim, Nahla Khamis; Kaki, Abdullah M.; Rohaiem, Sawsan M.; Qari, Mohamad H.; Tabsh, Laila M.; Aljawhari, Adel A.

    2017-01-01

    Objectives: To assess the effect of wet cupping on health-related quality of life (HRQOL) of adult patients with chronic medical conditions, who were referred to the Cupping Clinic of King Abdulaziz University Hospital (KAUH), Jeddah, Kingdom of Saudi Arabia. Methods: A controlled, quasi-experimental study design was carried out among 629 patients referred for cupping from the KAUH Specialty Clinics, during the period from January to December 2014. Patients in the intervention group (309 patients) completed a pre-test included WHO quality of life-BREF, received one wet-cupping session, and filled-out the post-test (1 month later). Patients in the control group (320 patients) completed the pre-test during their enrollment in the study and post-test one month later. Both groups received their ordinary treatment. Descriptive and inferential statistics were performed. Results: Pain was the most common cause for cupping referral. After cupping intervention, the mean scores of most of the HRQOL domains, especially the physical domain, improved significantly among patients in the intervention group. The mean total score of physical HRQOL domain was 61.6 ± 13.6 before cupping, and reached 69.7 ± 12.6 after intervention (paired t-test=11.3, p=0.000). Improvements in HRQOL were noticed for almost all types of pain and other medical conditions. Conclusion: There are promising effects in favor of using wet cupping for improving HRQOL of patients with chronic conditions. Cupping is recommended as a complementary treatment modality for chronic medical conditions, especially pain. PMID:28042631

  1. Vacuum delivery at The Maternity Hospital Kuala Lumpur: a comparison of metal and silicone cups.

    PubMed

    Lee, H Y; Subramaniam, N; Nordin, M M

    1996-02-01

    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries. A prospective randomised study of all vacuum deliveries from 1 December 1991 to 31 April 1992. The Hanshin electrical vacuum pump was used. A large obstetric unit-The Maternity Hospital Kuala Lumpur (MHKL). Seventy-two consecutive patients where vacuum deliveries were indicated. Forty had metal and 32 had silicone cups. Another 7 vacuum deliveries using the manual vacuum pump were excluded. Success rate of vaginal delivery, birth canal injuries, post-partum haemorrhage, duration of hospital stay, Apgar score, foetal injuries (scalp-ecchymosis, haematomas) neonatal jaundice, the rate of special care nursery (SCN) admission and neonatal mortality rate. Failure to deliver with silicone cups alone was 21.9% compared to 10% for metal cups alone. Material morbidities and serious foetal scalp injuries were almost the same in both cups. However, minor foetal scalp injuries were significantly lower with silicone cups. Maternal height and baby's weight had no independent predictive values for successful vacuum delivery. When the foetal head was palpable per abdomen, the failure rate was 54.5% compared to 8.2% when it was not. Failed vacuum deliveries were associated with increased maternal and foetal morbidities. Silicone cups and metal cups can be equally dangerous to the baby. Although our sample size was small, we recommend that vacuum delivery be avoided if the foetal head is palpable per abdomen.

  2. Feeding Neonates by Cup: A Systematic Review of the Literature.

    PubMed

    McKinney, Christy M; Glass, Robin P; Coffey, Patricia; Rue, Tessa; Vaughn, Matthew G; Cunningham, Michael

    2016-08-01

    Objective WHO and UNICEF recommend cup feeding for neonates unable to breastfeed in low-resource settings. In developed countries, cup feeding in lieu of bottle feeding in the neonatal period is hypothesized to improve breastfeeding outcomes for those initially unable to breastfeed. Our aim was to synthesize the entire body of evidence on cup feeding. Methods We searched domestic and international databases for original research. Our search criteria required original data on cup feeding in neonates published in English between January 1990 and December 2014. Results We identified 28 original research papers. Ten were randomized clinical trials, 7 non-randomized intervention studies, and 11 observational studies; 11 were conducted in developing country. Outcomes evaluated included physiologic stability, safety, intake, duration, spillage, weight gain, any and exclusive breastfeeding, length of hospital stay, compliance, and acceptability. Cup feeding appears to be safe though intake may be less and spillage greater relative to bottle or tube feeding. Overall, slightly higher proportions of cup fed versus bottle fed infants report any breastfeeding; a greater proportion of cup fed infants reported exclusive breastfeeding at discharge and beyond. Cup feeding increases breastfeeding in subgroups (e.g. those who intend to breastfeed or women who had a Caesarean section). Compliance and acceptability is problematic in certain settings. Conclusions Further research on long-term breastfeeding outcomes and in low-resource settings would be helpful. Research data on high risk infants (e.g. those with cleft palates) would be informative. Innovative cup feeding approaches to minimize spillage, optimize compliance, and increase breastfeeding feeding are needed.

  3. The translational regulator Cup controls NMJ presynaptic terminal morphology.

    PubMed

    Menon, Kaushiki P; Carrillo, Robert A; Zinn, Kai

    2015-07-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with two genes, EndoA and Dap160, that encode proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The translational regulator Cup controls NMJ presynaptic terminal morphology

    PubMed Central

    Menon, Kaushiki P.; Carrillo, Robert A.; Zinn, Kai

    2015-01-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with four genes (EndoA, WASp, Dap160, and Synj) encoding proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. PMID:26102195

  5. Chronological changes in functional cup position at 10 years after total hip arthroplasty.

    PubMed

    Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko

    2017-09-19

    This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p<0.01). The maximum postoperative change in F-Ant was 17.0° anteriorly; 12 cases (21%) showed a postoperative change in F-Ant by >10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.

  6. Cupping for stroke rehabilitation: a systematic review.

    PubMed

    Lee, Myeong Soo; Choi, Tae-Young; Shin, Byung-Cheul; Han, Chang-ho; Ernst, Edzard

    2010-07-15

    Cupping is often used for stroke rehabilitation in Asian countries. Currently, no systematic review of this topic is available. The aim of this systematic review is to summarize and critically evaluate the evidence for and against the effectiveness of cupping for stroke rehabilitation. Thirteen databases were searched from their inception through March of 2010 without language restrictions. Prospective clinical trials were included if cupping was tested as the sole treatment or as an adjunct to other conventional treatments for stroke rehabilitation. We found 43 potentially relevant articles, of which 5 studies including 3 randomized clinical trials (RCTs) and 2 uncontrolled observational studies (UOSs) met our inclusion criteria. Cupping was compared with acupuncture, electro-acupuncture and warm needling. Some superior effects of cupping were found in two of the RCTs when compared to acupuncture in hemiplegic shoulder pain and high upper-limb myodynamia after stroke. The other RCT failed to show favorable effects of cupping when compared to acupuncture and warm needling in patients with hemiplegic hand edema. The two UOSs reported favorable effects of cupping on aphasia and intractable hiccup after stroke. There are not enough trials to provide evidence for the effectiveness of cupping for stroke rehabilitation because most of the included trials compared the effects with unproven evidence and were not informative. Future RCTs seem warranted but must overcome the methodological shortcomings of the existing evidence. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Dual Mobility Cemented Cups Have Low Dislocation Rates in THA Revisions

    PubMed Central

    Langlais, Frantz L.; Gaucher, François; Musset, Thierry; Chaix, Olivier

    2008-01-01

    THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head ≥ 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108°). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65–86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196422

  8. Contact of dual mobility implants: effects of cup wear and inclination.

    PubMed

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.

  9. Spatial and Seasonal Distributions of Current Use Pesticides (CUPs) in the Atmospheric Particulate Phase in the Great Lakes Region.

    PubMed

    Wang, Shaorui; Salamova, Amina; Hites, Ronald A; Venier, Marta

    2018-06-05

    The authors analyzed spatial and seasonal variations of current use pesticides (CUPs) levels in the atmospheric particulate phase in the Great Lakes basin. Twenty-four hour air samples were collected at six sites (two urban, two rural, and two remote) in 2015. The concentrations of 15 CUPs, including nine pyrethroid insecticides, four herbicides, one organophosphate insecticide, and one fungicide, were measured. The total CUPs concentrations were higher at the urban sites (0.38-1760 pg/m 3 ) than at the rural and remote sites (0.07-530 pg/m 3 ). The most abundant CUPs were pyrethroid insecticides at the urban sites. The levels of the other CUPs did not vary much among the six sites, except at the most remote site at Eagle Harbor, where the levels were significantly lower. Chlorothalonil was the most frequently detected CUP, which was detected in more than 76% of the samples. The atmospheric concentrations of total pyrethroid insecticides and total herbicides were correlated with local human population and developed land use. Significantly higher concentrations of most CUPs were observed in the warmer months than in the colder months at all sites. In addition to agricultural applications, which occur during the warmer months, the CUPs atmospheric concentrations may also be influenced by nonagricultural activities and the urban development.

  10. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    PubMed

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  11. 75 FR 29889 - Special Local Regulation for Marine Event; 2010 International Cup Regatta, Pasquotank River...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ...-AA08 Special Local Regulation for Marine Event; 2010 International Cup Regatta, Pasquotank River... traffic in a portion of the Pasquotank River, near Elizabeth City, NC, during the 2010 International Cup... event in 33 CFR 100.501 and 33 CFR Table to Sec. 100.501, No. 54. On June 5 and 6, 2010, Carolina Cup...

  12. The Cup'ik People of the Western Tundra: A Curriculum.

    ERIC Educational Resources Information Center

    Pingayak, John

    The Cup'ik people are a group of Yup'ik Eskimos who live in southwest Alaska. This curriculum aims to enhance Cup'ik students' interest in their own culture by making that culture a part of their daily activities; to teach students to practice the traditional Cup'ik respect for elders, fellow students, and others in the community; and to teach…

  13. Semantics versus Statistics in the Retreat from Locative Overgeneralization Errors

    ERIC Educational Resources Information Center

    Ambridge, Ben; Pine, Julian M.; Rowland, Caroline F.

    2012-01-01

    The present study investigated how children learn that some verbs may appear in the figure-locative but not the ground-locative construction (e.g., "Lisa poured water into the cup"; "*Lisa poured the cup with water"), with some showing the opposite pattern (e.g., "*Bart filled water into the cup"; "Bart filled the cup with water"), and others…

  14. ION PRODUCING MECHANISM (CHARGE CUPS)

    DOEpatents

    Brobeck, W.W.

    1959-04-21

    The problems of confining a charge material in a calutron and uniformly distributing heat to the charge is described. The charge is held in a cup of thermally conductive material removably disposed within the charge chamber of the ion source block. A central thermally conducting stem is incorporated within the cup for conducting heat to the central portion of the charge contained within the cup.

  15. 16 CFR 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... flammable materials by Tagliabue open-cup apparatus. 1500.43 Section 1500.43 Commercial Practices CONSUMER... materials by Tagliabue open-cup apparatus. Scope 1. (a) This method describes a test procedure for the..., that is, ignite but not continue to burn. Apparatus 3. The Tag open-cup tester is illustrated in Fig. 1...

  16. 16 CFR 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... flammable materials by Tagliabue open-cup apparatus. 1500.43 Section 1500.43 Commercial Practices CONSUMER... materials by Tagliabue open-cup apparatus. Scope 1. (a) This method describes a test procedure for the..., that is, ignite but not continue to burn. Apparatus 3. The Tag open-cup tester is illustrated in Fig. 1...

  17. Deep Drawing Simulations With Different Polycrystalline Models

    NASA Astrophysics Data System (ADS)

    Duchêne, Laurent; de Montleau, Pierre; Bouvier, Salima; Habraken, Anne Marie

    2004-06-01

    The goal of this research is to study the anisotropic material behavior during forming processes, represented by both complex yield loci and kinematic-isotropic hardening models. A first part of this paper describes the main concepts of the `Stress-strain interpolation' model that has been implemented in the non-linear finite element code Lagamine. This model consists of a local description of the yield locus based on the texture of the material through the full constraints Taylor's model. The texture evolution due to plastic deformations is computed throughout the FEM simulations. This `local yield locus' approach was initially linked to the classical isotropic Swift hardening law. Recently, a more complex hardening model was implemented: the physically-based microstructural model of Teodosiu. It takes into account intergranular heterogeneity due to the evolution of dislocation structures, that affects isotropic and kinematic hardening. The influence of the hardening model is compared to the influence of the texture evolution thanks to deep drawing simulations.

  18. Identification of inelastic parameters based on deep drawing forming operations using a global-local hybrid Particle Swarm approach

    NASA Astrophysics Data System (ADS)

    Vaz, Miguel; Luersen, Marco A.; Muñoz-Rojas, Pablo A.; Trentin, Robson G.

    2016-04-01

    Application of optimization techniques to the identification of inelastic material parameters has substantially increased in recent years. The complex stress-strain paths and high nonlinearity, typical of this class of problems, require the development of robust and efficient techniques for inverse problems able to account for an irregular topography of the fitness surface. Within this framework, this work investigates the application of the gradient-based Sequential Quadratic Programming method, of the Nelder-Mead downhill simplex algorithm, of Particle Swarm Optimization (PSO), and of a global-local PSO-Nelder-Mead hybrid scheme to the identification of inelastic parameters based on a deep drawing operation. The hybrid technique has shown to be the best strategy by combining the good PSO performance to approach the global minimum basin of attraction with the efficiency demonstrated by the Nelder-Mead algorithm to obtain the minimum itself.

  19. Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers.

    PubMed

    Valstar, E R; Spoor, C W; Nelissen, R G; Rozing, P M

    1997-11-01

    A method for the detection of micromotion of a metal-backed hemispherical acetabular cup is presented and tested. Unlike in conventional roentgen stereophotogrammetric analysis, the cup does not have to be marked with tantalum markers; the micromotion is calculated from the contours of the hemispherical part and the base circle of the cup. In this way, two rotations (tilt and anteversion) and the translations along the three cardinal axes are obtained. In a phantom study, the maximum error in the position of the cup's centre was 0.04 mm. The mean error in the orientation of the cup was 0.41 degree, with a 95% confidence interval of 0.28-0.54 degree. The in vivo accuracy was tested by repeated measurement of 21 radiographs from seven patients. The upper bound of the 95% tolerance interval for the translations along the transversal, longitudinal, and sagittal axes was 0.09, 0.07, and 0.34 mm, respectively: for the rotation, this upper bound was 0.39 degree. These results show that the new method, in which the position and orientation of metal-backed hemispherical cup is calculated from its projected contours, is a simple and accurate alternative to attaching markers to the cup.

  20. The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2016-08-01

    The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Chimpanzees Sometimes See Fuller as Better: Judgments of Food Quantities Based on Container Size and Fullness

    PubMed Central

    Parrish, Audrey E.; Beran, Michael J.

    2014-01-01

    The context in which food is presented can alter quantity judgments leading to sub-optimal choice behavior. Humans often over-estimate food quantity on the basis of how food is presented. Food appears larger if plated on smaller dishes than larger dishes and liquid volumes appear larger in taller cups than shorter cups. Moreover, smaller but fuller containers are preferred in comparison to larger, but less full containers with a truly larger quantity. Here, we assessed whether similar phenomena occur in chimpanzees. Four chimpanzees chose between two amounts of food presented in different sized containers, a large (2 oz.) and small (1 oz.) cup. When different quantities were presented in the same-sized cups or when the small cup contained the larger quantity, chimpanzees were highly accurate in choosing the larger food amount. However, when different-sized cups contained the same amount of food or the smaller cup contained the smaller amount of food (but looked relatively fuller), the chimpanzees often showed a bias to select the smaller but fuller cup. These findings contribute to our understanding of how quantity estimation and portion judgment is impacted by the surrounding context in which it is presented. PMID:24374384

  2. CUP-1 Is a Novel Protein Involved in Dietary Cholesterol Uptake in Caenorhabditis elegans

    PubMed Central

    Valdes, Victor J.; Athie, Alejandro; Salinas, Laura S.; Navarro, Rosa E.; Vaca, Luis

    2012-01-01

    Sterols transport and distribution are essential processes in all multicellular organisms. Survival of the nematode Caenorhabditis elegans depends on dietary absorption of sterols present in the environment. However the general mechanisms associated to sterol uptake in nematodes are poorly understood. In the present work we provide evidence showing that a previously uncharacterized transmembrane protein, designated Cholesterol Uptake Protein-1 (CUP-1), is involved in dietary cholesterol uptake in C. elegans. Animals lacking CUP-1 showed hypersensitivity to cholesterol limitation and were unable to uptake cholesterol. A CUP-1-GFP fusion protein colocalized with cholesterol-rich vesicles, endosomes and lysosomes as well as the plasma membrane. Additionally, by FRET imaging, a direct interaction was found between the cholesterol analog DHE and the transmembrane “cholesterol recognition/interaction amino acid consensus” (CRAC) motif present in C. elegans CUP-1. In-silico analysis identified two mammalian homologues of CUP-1. Most interestingly, CRAC motifs are conserved in mammalian CUP-1 homologous. Our results suggest a role of CUP-1 in cholesterol uptake in C. elegans and open up the possibility for the existence of a new class of proteins involved in sterol absorption in mammals. PMID:22479487

  3. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy

    PubMed Central

    Li, Ting; Li, Yaoxian; Lin, Yu; Li, Kai

    2016-01-01

    Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO2]), deoxy-hemoglobin ([Hb]), and blood volume in the course of cupping therapy over 13 volunteers on the infraspinatus muscle, where is usually applied for shoulder pains. Both a prominent drop in [Hb] and a significant elevation in [HbO2] in the tissue surrounding the cupping site were observed during both cupping and post-treatment, manifesting the enhancement of oxygen uptake. This resulting promotion indicates potential positive therapeutic effect of cupping therapy in hemodynamics for facilitating muscular functions. PMID:28101413

  4. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    PubMed Central

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  5. A Quality Model to Select Patients in Cupping Therapy Clinics: A New Tool for Ensuring Safety in Clinical Practice.

    PubMed

    Aboushanab, Tamer; AlSanad, Saud

    2018-06-08

    Cupping therapy is a popular treatment in various countries and regions, including Saudi Arabia. Cupping therapy is regulated in Saudi Arabia by the National Center for Complementary and Alternative Medicine (NCCAM), Ministry of Health. The authors recommend that this quality model for selecting patients in cupping clinics - first version (QMSPCC-1) - be used routinely as part of clinical practice and quality management in cupping clinics. The aim of the quality model is to ensure the safety of patients and to introduce and facilitate quality and auditing processes in cupping therapy clinics. Clinical evaluation of this tool is recommended. Continued development, re-evaluation and reassessment of this tool are important. Copyright © 2018. Published by Elsevier B.V.

  6. Gas-Diverting Cup For Welding At An Angle

    NASA Technical Reports Server (NTRS)

    Dyer, G. E.

    1988-01-01

    Attachment makes automatic arc welders more versatile. Stainless-steel diverting cup slips over standard torch cup. Bent electrode inserted in torch. Assembly reaches weld joints inaccessible to straight welding torch.

  7. "Greening" a Familiar General Chemistry Experiment: Coffee Cup Calorimetry to Determine the Enthalpy of Neutralization of an Acid-Base Reaction and the Specific Heat Capacity of Metals

    ERIC Educational Resources Information Center

    Bopegedera, A. M. R. P.; Perera, K. Nishanthi R.

    2017-01-01

    Coffee cup calorimetry, performed with calorimeters made with styrofoam coffee cups, is a familiar experiment in the general chemistry laboratory. These calorimeters are inexpensive, easy to use, and provide good insulation for most thermodynamics experiments. This paper presents the successful substitution of paper coffee cups for styrofoam cups…

  8. Comparative study of optic disc measurement by Copernicus optical coherence tomography and Heidelberg retinal tomography.

    PubMed

    Yang, Qing-Song; Yu, Ya-Jie; Li, Shu-Ning; Liu, Juan; Hao, Ying-Juan

    2012-08-01

    Copernicus optical coherence tomography (SOCT) is a new, ultra high-speed and high-resolution instrument available for clinical evaluation of optic nerve. The purpose of the study was to compare the agreements between SOCT and Heidelberg retinal tomography (HRT). A total of 44 healthy normal volunteers were recruited in this study. One eye in each subject was selected randomly. Agreement between SOCT and HRT-3 in measuring optic disc area was assessed using Bland-Altman plots. Relationships between measurements of optic nerve head parameter obtained by SOCT and HRT-3 were assessed by Pearson correlation. There was no significant difference in the average cup area (0.306 vs. 0.355 mm, P = 0.766), cup volume (0.158 vs. 0.130 mm, P = 0.106) and cup/disc ration (0.394 vs. 0.349 mm, P = 0.576) measured by the two instruments. However, other optic disc parameters from SOCT were significantly lower compared with HRT-3. The Bland-Altman plot revealed good agreement of cup area and cup volume measured by SOCT and HRT-3. Bad agreement of disc area, rim area, rim volume and cup/disc ratio were found between SOCT and HRT-3. The highest correlations between the two instruments were observed for cup area (r(2) = 0.783, P = 0.000) and cup/disc ratio (r(2) = 0.669, P = 0.000), whereas the lowest correlation was observed for disc area (r(2) = 0.100, P = 0.037), rim area (r(2) = 0.275, P = 0.000), cup volume (r(2) = 0.005, P = 0.391) and rim volume (r(2) = 0.021, P = 0.346). There were poor agreements between SOCT and HRT-3 for measurement of optic nerve parameters except cup area and cup volume. Measurement results of the two instruments are not interchangeable.

  9. Menu Ideas for Vegetarian Teens

    MedlinePlus

    ... 1 ounce pistachios Snack 8 ounces Greek style yogurt ¼ cup granola 1 apple 1 ounce almonds ... Jicama Salad Recipe Recipes Jicama Salad Recipe Rainbow Yogurt Trifle Cups Recipe Recipes Rainbow Yogurt Trifle Cups ...

  10. A novel approach to determine primary stability of acetabular press-fit cups.

    PubMed

    Weißmann, Volker; Boss, Christian; Bader, Rainer; Hansmann, Harald

    2018-04-01

    Today hip cups are used in a large variety of design variants and in increasing numbers of units. Their development is steadily progressing. In addition to conventional manufacturing methods for hip cups, additive methods, in particular, play an increasingly important role as development progresses. The present paper describes a modified cup model developed based on a commercially available press-fit cup (Allofit 54/JJ). The press-fit cup was designed in two variants and manufactured using selective laser melting (SLM). Variant 1 (Ti) was modeled on the Allofit cup using an adapted process technology. Variant 2 (Ti-S) was provided with a porous load bearing structure on its surface. In addition to the typical (complete) geometry, both variants were also manufactured and tested in a reduced shape where only the press-fit area was formed. To assess the primary stability of the press-fit cups in the artificial bone cavity, pull-out and lever-out tests were carried out. Exact fit conditions and two-millimeter press-fit were investigated. The closed-cell PU foam used as an artificial bone cavity was mechanically characterized to exclude any influence on the results of the investigation. The pull-out forces of the Ti-variant (complete-526 N, reduced-468 N) and the Ti-S variant (complete-548 N, reduced-526 N) as well as the lever-out moments of the Ti-variant (complete-10 Nm, reduced-9.8 Nm) and the Ti-S variant (complete-9 Nm, reduced-7.9 N) show no significant differences in the results between complete and reduced cups. The results show that the use of reduced cups in a press-fit design is possible within the scope of development work. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. [Clinical observation on therapeutic effect of cupping combined with acupuncture stimulation at trigger points for lumbar myofascial pain syndrome].

    PubMed

    Zhao, Hong

    2014-08-01

    To observe the clinical effect of cupping combined with acupuncture stimulation of trigger points on lumbar myofascial pain syndrome (MPS). Sixty MPS patients were randomly divided into acupuncture + TDP group (n = 30), and cupping + acupuncture group (n = 30). Patients in the acupuncture + TDP group were treated by acupuncture stimulation of trigger points and local TDP irradiation, and patients of the cupping + acupuncture group treated by intensive cupping applied to the myofascial band and acupuncture stimulation of the locus according to the position of muscular tension band. The therapeutic effects were assessed according to the score of the McGill pain questionnaire composing of pain rating index (PRI), visual analogue scale (VAS) and present pain intensity (PPI) before, immediately and 1 month after the treatment. After the treatment, the total effective rates of the acupuncture+ TDP and cupping + acupuncture groups were 83.3% (25/30) and 96.6% (29/30), respectively, without significant difference between the two groups (P > 0.05). One month's follow-up showed that the total effective rates of the acupuncture + TDP and cupping + acupuncture groups were 40.0% and 90.0% respectively, and the latter group was significantly better than the acupuncture + TDP group in the therapeutic effect (P < 0.05). The scores of PRI, VAS, PPI after the treatment were markedly decreased in both groups (P < 0.05). One month later, the scores of PRI, VAS and PPI in the cupping + acupuncture group were obviously lower than those of the acupuncture group (P < 0.05). Both acupuncture stimulation of trigger points plus TDP and cupping plus acupuncture can effectively relieve pain in MPS patients, while the therapeutic effect of cupping plus acupuncture treatment lasts longer analgesic effect.

  12. Prospective study of coffee consumption and all-cause, cancer, and cardiovascular mortality in Swedish women.

    PubMed

    Löf, Marie; Sandin, Sven; Yin, Li; Adami, Hans-Olov; Weiderpass, Elisabete

    2015-09-01

    We investigated whether coffee consumption was associated with all-cause, cancer, or cardiovascular mortality in a prospective cohort of 49,259 Swedish women. Of the 1576 deaths that occurred in the cohort, 956 were due to cancer and 158 were due to cardiovascular disease. We used Cox proportional hazard models with adjustment for potential confounders to estimate multivariable relative risks (RR) and 95 % confidence intervals (CI). Compared to a coffee consumption of 0-1 cups/day, the RR for all cause-mortality was 0.81 (95 % CI 0.69-0.94) for 2-5 cups/day and 0.88 (95 % CI 0.74-1.05) for >5 cups/day. Coffee consumption was not associated with cancer mortality or cardiovascular mortality when analyzed in the entire cohort. However, in supplementary analyses of women over 50 years of age, the RR for all cause-mortality was 0.74 (95 % CI 0.62-0.89) for 2-5 cups/day and 0.86 (95 % CI 0.70-1.06) for >5 cups/day when compared to 0-1 cups/day. In this same subgroup, the RRs for cancer mortality were 1.06 (95 % CI 0.81-1.38) for 2-5 cups/day and 1.40 (95 % CI 1.05-1.89) for >5 cups/day when compared to 0-1 cups/day. No associations between coffee consumption and all-cause mortality, cancer mortality, or cardiovascular mortality were observed among women below 50 years of age. In conclusion, higher coffee consumption was associated with lower all-cause mortality when compared to a consumption of 0-1 cups/day. Furthermore, coffee may have differential effects on mortality before and after 50 years of age.

  13. Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty.

    PubMed

    Gonzalez, Amanda Inez; Bartolone, Placido; Lubbeke, Anne; Dupuis Lozeron, Elise; Peter, Robin; Hoffmeyer, Pierre; Christofilopoulos, Panayiotis

    2017-02-01

    Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.

  14. Crystal structure of a minimal eIF4E–Cup complex reveals a general mechanism of eIF4E regulation in translational repression

    PubMed Central

    Kinkelin, Kerstin; Veith, Katharina; Grünwald, Marlene; Bono, Fulvia

    2012-01-01

    Cup is an eIF4E-binding protein (4E-BP) that plays a central role in translational regulation of localized mRNAs during early Drosophila development. In particular, Cup is required for repressing translation of the maternally contributed oskar, nanos, and gurken mRNAs, all of which are essential for embryonic body axis determination. Here, we present the 2.8 Å resolution crystal structure of a minimal eIF4E–Cup assembly, consisting of the interacting regions of the two proteins. In the structure, two separate segments of Cup contact two orthogonal faces of eIF4E. The eIF4E-binding consensus motif of Cup (YXXXXLΦ) binds the convex side of eIF4E similarly to the consensus of other eIF4E-binding proteins, such as 4E-BPs and eIF4G. The second, noncanonical, eIF4E-binding site of Cup binds laterally and perpendicularly to the eIF4E β-sheet. Mutations of Cup at this binding site were shown to reduce binding to eIF4E and to promote the destabilization of the associated mRNA. Comparison with the binding mode of eIF4G to eIF4E suggests that Cup and eIF4G binding would be mutually exclusive at both binding sites. This shows how a common molecular surface of eIF4E might recognize different proteins acting at different times in the same pathway. The structure provides insight into the mechanism by which Cup disrupts eIF4E–eIF4G interaction and has broader implications for understanding the role of 4E-BPs in translational regulation. PMID:22832024

  15. Nitrate Contamination of Deep Aquifers in the Salinas Valley, California

    NASA Astrophysics Data System (ADS)

    Moran, J. E.; Esser, B. K.; Hillegonds, D. J.; Holtz, M.; Roberts, S. K.; Singleton, M. J.; Visser, A.; Kulongoski, J. T.; Belitz, K.

    2011-12-01

    The Salinas Valley, known as 'the salad bowl of the world', has been an agricultural center for more than 100 years. Irrigated row crops such as lettuce and strawberries dominate both land use and water use. Groundwater is the exclusive supply for both irrigation and drinking water. Some irrigation wells and most public water supply wells in the Salinas Valley are constructed to draw water from deep portions of the aquifer system, where contamination by nitrate is less likely than in the shallow portions of the aquifer system. However, a number of wells with top perforations greater than 75 m deep, screened below confining or semi-confining units, have nitrate concentrations greater than the Maximum Contaminant Limit (MCL) of 45 mg/L as NO3-. This study uses nitrate concentrations from several hundred irrigation, drinking water, and monitoring wells (Monterey County Water Resources Agency, 1997), along with tritium-helium groundwater ages acquired at Lawrence Livermore National Laboratory through the State of California Groundwater Monitoring and Assessment (GAMA) program (reported in Kulongoski et al., 2007 and in Moran et al., in press), to identify nitrate 'hot spots' in the deep aquifer and to examine possible modes of nitrate transport to the deep aquifer. In addition, observed apparent groundwater ages are compared with the results of transport simulations that use particle tracking and a stochastic-geostatistical framework to incorporate aquifer heterogeneity to determine the distribution of travel times from the water table to each well (Fogg et al., 1999). The combined evidence from nitrate, tritium, tritiogenic 3He, and radiogenic 4He concentrations, reveals complex recharge and flow to the capture zone of the deep drinking water wells. Widespread groundwater pumping for irrigation accelerates vertical groundwater flow such that high nitrate groundwater reaches some deep drinking water wells. Deeper portions of the wells often draw in water that recharged before agricultural activity began in the valley, while some shallower intervals draw in recycled irrigation water which can have a low tritium concentration but high nitrate concentration. The irrigation return water may take a decade or more to reach the water table, given that the vadose zone in some affected areas is more than 30 m deep, but downward migration is likely enhanced by preferential flow paths, plowing, crop removal, and sprinkler irrigation in surrounding fields. This work was performed under the auspices of the U.S. DOE by LLNL under Contract DE-AC52-07NA27344. Fogg et al., 1999, in AGU Geophysical Monograph 108. Kulongoski et al., 2007. USGS Data Series Report 167 Monterey County Water Agency, 1997. Water Resources Data Report (Water Year 1994-1995) Moran et al., 2011. California GAMA Special Study: Nitrate Fate and Transport in the Salinas Valley. LLNL, in press.

  16. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    PubMed

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  17. The current evidence for a biomarker-based approach in cancer of unknown primary.

    PubMed

    El Rassy, Elie; Pavlidis, Nicholas

    2018-05-02

    Cancer of unknown primary (CUP) accounts for the seventh to eighth most frequently diagnosed cancer yet its prognosis remains poor with conventional chemotherapy. The spectrum of therapeutic management includes both locoregional and systemic therapy and should intend to offer optimal benefit to favorable CUP patients and palliative care to unfavorable cases. The recent molecular advances have revolutionized the armamentarium of cancer treatments though a biomarker-based approach. Unfortunately, solid data in CUP is lacking in the absence of a CUP-specific driver molecular signature. This prompted us to screen the medical literature for clinical data that evaluates the efficacy and safety of the biomarker-based approach in CUP patients. In this review, we will summarize the available evidence for the applicability of targeted therapies in CUP. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Automated detection of kinks from blood vessels for optic cup segmentation in retinal images

    NASA Astrophysics Data System (ADS)

    Wong, D. W. K.; Liu, J.; Lim, J. H.; Li, H.; Wong, T. Y.

    2009-02-01

    The accurate localization of the optic cup in retinal images is important to assess the cup to disc ratio (CDR) for glaucoma screening and management. Glaucoma is physiologically assessed by the increased excavation of the optic cup within the optic nerve head, also known as the optic disc. The CDR is thus an important indicator of risk and severity of glaucoma. In this paper, we propose a method of determining the cup boundary using non-stereographic retinal images by the automatic detection of a morphological feature within the optic disc known as kinks. Kinks are defined as the bendings of small vessels as they traverse from the disc to the cup, providing physiological validation for the cup boundary. To detect kinks, localized patches are first generated from a preliminary cup boundary obtained via level set. Features obtained using edge detection and wavelet transform are combined using a statistical approach rule to identify likely vessel edges. The kinks are then obtained automatically by analyzing the detected vessel edges for angular changes, and these kinks are subsequently used to obtain the cup boundary. A set of retinal images from the Singapore Eye Research Institute was obtained to assess the performance of the method, with each image being clinically graded for the CDR. From experiments, when kinks were used, the error on the CDR was reduced to less than 0.1 CDR units relative to the clinical CDR, which is within the intra-observer variability of 0.2 CDR units.

  19. Effects of wet-cupping on blood pressure in hypertensive patients: a randomized controlled trial.

    PubMed

    Aleyeidi, Nouran A; Aseri, Khaled S; Matbouli, Shadia M; Sulaiamani, Albaraa A; Kobeisy, Sumayyah A

    2015-11-01

    Although cupping remains a popular treatment modality worldwide, its efficacy for most diseases, including hypertension, has not been scientifically evaluated. We aimed to determine the efficacy of wet-cupping for high blood pressure, and the incidence of the procedure's side effects in the intervention group. This is a randomized controlled trial conducted in the General Practice Department at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between May 2013 and February 2014. There were two groups (40 participants each): intervention group undergoing wet-cupping (hijama) in addition to conventional hypertension treatment, and a control group undergoing only conventional hypertension treatment. Three wet-cupping sessions were performed every other day. The mean systolic and diastolic blood pressures were measured using a validated automatic sphygmomanometer. The follow-up period was 8 weeks. Wet-cupping provided an immediate reduction of systolic blood pressure. After 4 weeks of follow-up, the mean systolic blood pressure in the intervention group was 8.4 mmHg less than in the control group (P=0.046). After 8 weeks, there were no significant differences in blood pressures between the intervention and control groups. In this study, wet-cupping did not result in any serious side effects. Wet-cupping therapy is effective for reducing systolic blood pressure in hypertensive patients for up to 4 weeks, without serious side effects. Wet-cupping should be considered as a complementary hypertension treatment, and further studies are needed. ClinicalTrials.gov Identifier NCT01987583.

  20. Köebner phenomenon induced by cupping therapy in a psoriasis patient.

    PubMed

    Yu, Rui-Xing; Hui, Yun; Li, Cheng-Rang

    2013-06-15

    Psoriasis is a chronic, immune-mediated inflammatory and refractory disease. The koebner phenomenon, which can be induced by trauma, is common in psoriasis patients. Herein, we report a patient with psoriasis who was treated by cupping therapy and subsequently developed the koebner phenomenon (KP) at the cupped sites. To our knowledge, it is the first report about cupping therapy leading to KP in a psoriasis patient.

  1. [Effect of cupping on hemodynamic levels in the regional sucked tissues in patients with lumbago].

    PubMed

    Tang, Xiao; Xiao, Xue-Hua; Zhang, Guo-Qing

    2012-10-01

    To observe hemodynamic changes in the local sucked tissue of lower back undergoing negative pressure after cupping in patients with lumbago. Twenty-two lumbago outpatients were recruited in the present study and 32 sucked tissues accepted measurements. The cupping was applied to the tenderpoint of the patients' lower back for 10 min by using a glass-mug (5 cm in diameter). Hemodynamic indexes [peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI)] of the sucked skin and subcutaneous tissues at the lower back were detected before and after cupping by using a color Doppler flow imaging. After cupping intervention at the lower back, the PSV [(14.2 +/- 1.8) cm/s] and EDV [(5.5 +/- 0.7) cm/s] levels were increased significantly in comparison with those [(5.9 +/- 0.9) and (1.9 +/- 0.3) cm/s] before cupping (P < 0.01), while RI was reduced evidently after cupping (0.61 +/- 0.05 vs 0.68 +/- 0.06, P < 0.01), suggesting an increase of the regional blood flow. Cupping therapy can increase the peak systolic velocity and end-diastolic velocity and lower vascular resistance of the subcutaneous arterioles in the regional tissue, which may contribute to its effect in relieving lumbago.

  2. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction

    PubMed Central

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu’s segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images. PMID:28515636

  3. Optic cup segmentation: type-II fuzzy thresholding approach and blood vessel extraction.

    PubMed

    Almazroa, Ahmed; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    We introduce here a new technique for segmenting optic cup using two-dimensional fundus images. Cup segmentation is the most challenging part of image processing of the optic nerve head due to the complexity of its structure. Using the blood vessels to segment the cup is important. Here, we report on blood vessel extraction using first a top-hat transform and Otsu's segmentation function to detect the curves in the blood vessels (kinks) which indicate the cup boundary. This was followed by an interval type-II fuzzy entropy procedure. Finally, the Hough transform was applied to approximate the cup boundary. The algorithm was evaluated on 550 fundus images from a large dataset, which contained three different sets of images, where the cup was manually marked by six ophthalmologists. On one side, the accuracy of the algorithm was tested on the three image sets independently. The final cup detection accuracy in terms of area and centroid was calculated to be 78.2% of 441 images. Finally, we compared the algorithm performance with manual markings done by the six ophthalmologists. The agreement was determined between the ophthalmologists as well as the algorithm. The best agreement was between ophthalmologists one, two and five in 398 of 550 images, while the algorithm agreed with them in 356 images.

  4. Human coffee drinking: manipulation of concentration and caffeine dose.

    PubMed Central

    Griffiths, R R; Bigelow, G E; Liebson, I A; O'Keeffe, M; O'Leary, D; Russ, N

    1986-01-01

    In a residential research ward coffee drinking was studied in 9 volunteer human subjects with histories of heavy coffee drinking. A series of five experiments was undertaken to characterize adlibitum coffee consumption and to investigate the effects of manipulating coffee concentration, caffeine dose per cup, and caffeine preloads prior to coffee drinking. Manipulations were double-blind and scheduled in randomized sequences across days. When cups of coffee were freely available, coffee drinking tended to be rather regularly spaced during the day with intercup intervals becoming progressively longer throughout the day; experimental manipulations showed that this lengthening of intercup intervals was not due to accumulating caffeine levels. Number of cups of coffee consumed was an inverted U-shaped function of both coffee concentration and caffeine dose per cup; however, coffee-concentration and dose-per-cup manipulations did not produce similar effects on other measures of coffee drinking (intercup interval, time to drink a cup, within-day distribution of cups). Caffeine preload produced dose-related decreases in number of cups consumed. As a whole, these experiments provide some limited evidence for both the suppressive and the reinforcing effects of caffeine on coffee consumption. Examination of total daily coffee and caffeine intake across experiments, however, provides no evidence for precise regulation (i.e., titration) of coffee or caffeine intake. PMID:3958660

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu Jing; Rovey, Joshua L.

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fallmore » time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.« less

  6. Quick Beef Casserole

    MedlinePlus

    ... teaspoon of salt 1/2 teaspoon of ground black pepper 1/4 teaspoon of paprika 1 cup of frozen peas 2 small carrots, rinsed, peeled, and diced 1 cup of uncooked rice 1 and 1/2 cups of water Directions ...

  7. Keep the Beat Recipes | NIH MedlinePlus the Magazine

    MedlinePlus

    ... Cup celery, rinsed and diced 1 Cup pearl onions, raw or frozen 3 Cup low-sodium chicken ... 5 minutes. Add leeks, potatoes, celery, and pearl onions, and continue to cook until the vegetables become ...

  8. Snacks for adults

    MedlinePlus

    ... into wedges), 1 medium or ¼ cup (35 grams) Bananas, 1 medium Raisins, ¼ cup (35 grams) Fruit leather (dried fruit puree) without added sugar ... into strips, or baby carrots ), 1 cup (130 grams) Snap peas (the pods are edible), 1.5 ...

  9. 6 Easy Steps toward healthier eating | NIH MedlinePlus the Magazine

    MedlinePlus

    ... Good Smoothie Ingredients: 1 cup low-fat strawberry yogurt 1 cup orange juice with added calcium 1 ... cup frozen raspberries Instructions: Combine the low-fat yogurt and the orange juice in a blender and ...

  10. Fast-response cup anemometer features cosine response

    NASA Technical Reports Server (NTRS)

    Frenzen, P.

    1968-01-01

    Six-cup, low-inertia anemometer combines high resolution and fast response with a unique ability to sense only the horizontal component of the winds fluctuating rapidly in three dimensions. Cup assemblies are fabricated of expanded polystyrene plastic.

  11. Lamp with a truncated reflector cup

    DOEpatents

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  12. Finger-triggered portable PDMS suction cup for equipment-free microfluidic pumping

    NASA Astrophysics Data System (ADS)

    Lee, Sanghyun; Kim, Hojin; Lee, Wonhyung; Kim, Joonwon

    2018-12-01

    This study presents a finger-triggered portable polydimethylsiloxane suction cup that enables equipment-free microfluidic pumping. The key feature of this method is that its operation only involves a "pressing-and-releasing" action for the cup placed at the outlet of a microfluidic device, which transports the fluid at the inlet toward the outlet through a microchannel. This method is simple, but effective and powerful. The cup is portable and can easily be fabricated from a three-dimensional printed mold, used without any pre-treatment, reversibly bonded to microfluidic devices without leakage, and applied to various material-based microfluidic devices. The effect of the suction cup geometry and fabrication conditions on the pumping performance was investigated. Furthermore, we demonstrated the practical applications of the suction cup by conducting an equipment-free pumping of thermoplastic-based microfluidic devices and water-in-oil droplet generation.

  13. Magnetic core mounting system

    DOEpatents

    Ronning, Jeffrey J.

    2002-01-01

    A mounting apparatus for an electromagnetic device such as a transformer of inductor includes a generally planar metallic plate as a first heat sink, and a metallic mounting cup as a second heat sink. The mounting cup includes a cavity configured to receive the electromagnetic device, the cavity being defined by a base, and an axially-extending annular sidewall extending from the base to a flange portion of the mounting cup. The mounting cup includes first and second passages for allowing the leads of first and second windings of the electromagnetic device to be routed out of the cavity. The cavity is filled with a polyurethane potting resin, and the mounting cup, including the potted electromagnetic device, is mounted to the plate heat sink using fasteners. The mounting cup, which surrounds the electromagnetic device, in combination with the potting resin provides improved thermal transfer to the plate heat sink, as well as providing resistance to vibration and shocks.

  14. Assessing the Linguistic Productivity of Unsupervised Deep Neural Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, Lawrence A.; Hodas, Nathan O.

    Increasingly, cognitive scientists have demonstrated interest in applying tools from deep learning. One use for deep learning is in language acquisition where it is useful to know if a linguistic phenomenon can be learned through domain-general means. To assess whether unsupervised deep learning is appropriate, we first pose a smaller question: Can unsupervised neural networks apply linguistic rules productively, using them in novel situations. We draw from the literature on determiner/noun productivity by training an unsupervised, autoencoder network measuring its ability to combine nouns with determiners. Our simple autoencoder creates combinations it has not previously encountered, displaying a degree ofmore » overlap similar to actual children. While this preliminary work does not provide conclusive evidence for productivity, it warrants further investigation with more complex models. Further, this work helps lay the foundations for future collaboration between the deep learning and cognitive science communities.« less

  15. A critical comparison of ten disposable cup LCAs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harst, Eugenie van der, E-mail: eugenie.vanderharst@wur.nl; Potting, José, E-mail: jose.potting@wur.nl; Environmental Strategies Research

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) alsomore » shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches.« less

  16. Second-order motor planning in children: insights from a cup-manipulation-task.

    PubMed

    Wunsch, Kathrin; Weiss, Daniel J; Schack, Thomas; Weigelt, Matthias

    2015-07-01

    The present study examined the development of anticipatory motor planning in an object manipulation task that has been used to successfully demonstrate motor planning in non-human primates (Weiss et al. in Psychol Sci 18:1063-1068, 2007). Seventy-five participants from four different age groups participated in a cup-manipulation task. One group was preschool children (average age of 5.1 years), two groups were primary school children (7.7 and 9.8 years old respectively) and the final group was comprised of adults. The experimental task entailed reaching for a plastic cup that was vertically suspended in an apparatus in either upright or inverted orientation, removing the cup by its stem and then retrieving a small toy from the inside of the cup. When the cup was inverted in the apparatus, evidence for anticipatory motor planning could be achieved by initially gripping the stem using an inverted (thumb-down) grip posture. We found that when the cup was in upright orientation, all participants reached for the cup using an upright grip (i.e., thumb-up posture). However, when the cup was inverted in the apparatus, only adults consistently used an inverted grasping posture, though the percentage of inverted grips among participants did increase with age. These results suggest a protracted development for anticipatory motor planning abilities in children. Surprisingly, the performance of adults on this task more closely resembles the performance of several nonhuman primate species as opposed to children even at approximately 10 years of age. We discuss how morphological constraints on flexibility may help account for these findings.

  17. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    PubMed

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. The benefit of cup medialization is variable and depends on the individual anatomy. Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.

  18. Reduction by coffee consumption of prostate cancer risk: Evidence from the Moli-sani cohort and cellular models.

    PubMed

    Pounis, George; Tabolacci, Claudio; Costanzo, Simona; Cordella, Martina; Bonaccio, Marialaura; Rago, Livia; D'Arcangelo, Daniela; Filippo Di Castelnuovo, Augusto; de Gaetano, Giovanni; Donati, Maria Benedetta; Iacoviello, Licia; Facchiano, Francesco

    2017-07-01

    Meta-analytic data on the effect of coffee in prostate cancer risk are controversial. Caffeine as a bioactive compound of coffee has not yet been studied in deep in vitro. Our study aimed at evaluating in a population cohort the effect of Italian-style coffee consumption on prostate cancer risk and at investigating in vitro the potential antiproliferative and antimetastatic activity of caffeine on prostate cancer cell lines. 6,989 men of the Moli-sani cohort aged ≥50 years were followed for a mean of 4.24 ± 1.35 years and 100 new prostate cancer cases were identified. The European Prospective Investigation into Cancer and Nutrition-Food Frequency Questionnaire was used for the dietary assessment and the evaluation of Italian-style coffee consumption. Two human prostate cancer cell lines, PC-3 and DU145, were tested with increasing concentrations of caffeine, and their proliferative/metastatic features were evaluated. The newly diagnosed prostate cancer participants presented lower coffee consumption (60.1 ± 51.3 g/day) compared to the disease-free population (74.0 ± 51.7 g/day) (p < 0.05). Multiadjusted analysis showed that the subjects at highest consumption (>3 cups/day) had 53% lower prostate cancer risk as compared to participants at the lowest consumption (0-2 cups/day) (p = 0.02). Both human prostate cancer cell lines treated with caffeine showed a significant reduction in their proliferative and metastatic behaviors (p < 0.05). In conclusion, reduction by Italian-style coffee consumption of prostate cancer risk (>3 cups/day) was observed in epidemiological level. Caffeine appeared to exert both antiproliferative and antimetastatic activity on two prostate cancer cell lines, thus providing a cellular confirmation for the cohort study results. © 2017 UICC.

  19. Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach?

    PubMed

    Song, Xinggui; Ni, Ming; Li, Heng; Li, Xin; Li, Xiang; Fu, Jun; Chen, Jiying

    2018-05-23

    The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone. The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared. The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p < 0.001). The mean abduction was 37.50 (37.50° ± 6.76°) in left THA and 38.59 (38.59° ± 6.84°) in right THA (p = 0.011). In the left side, the cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p < 0.001) and for both anteversion and inclination (p < 0.001). Dislocation occurred in 7.0% (35/498) of cases in left THA and 3.2% (16/498) in right THA. The percentages of patients experiencing dislocation were significantly different between the two sides (p = 0.006). This current study demonstrated that surgeon handedness is likely to be a contributing factor that affects cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.

  20. Differential effects of tamoxifen and anastrozole on optic cup size in breast cancer survivors

    PubMed Central

    Toomey, Maureen D.; Falardeau, Julie; Samples, John R.; Vetto, John T.

    2007-01-01

    Introduction The main purpose of this study was to determine whether the optic cups of tamoxifen users and anastrozole users differ in size, with the cups of the tamoxifen users being smaller. Methods Optic nerve head (ONH) topography was measured using a commercially available, confocal scanning laser ophthalmoscope for three populations of amenorrheic women ages 40–69 years: subjects using (1) tamoxifen (20 mg/day) or (2) anastrozole (1 mg/day) for ≤ 2 years as adjuvant therapy after successful primary treatment for breast cancer, and (3) control subjects with no breast cancer histories and not using any hormonal medication. All subjects had excellent visual acuity and healthy eyes, based on conventional photographic assessment. Results The cup volumes of the tamoxifen users were shown to be significantly smaller than the cup volumes of the anastrozole users, which were indistinguishable from normal. Because the cup volumes of the tamoxifen users decreased markedly with age at about 50 years and because anastrozole is indicated only for post-menopausal women, comparisons were reassessed for subjects older than 50 years. For these subjects, the cup volumes of the tamoxifen users averaged less than half of the volumes for each of the other two subject groups, and significant between-group differences existed in both the lateral (cup area) and axial (cup depth) directions. In contrast, any between-group differences at the ONH margin were small and not significant. Conclusions The results of this study suggest that the ONH be assessed biomorphometrically for tamoxifen users reporting visual change that cannot be attributed to non-tamoxifen causes. The ability of modern intraocular imaging techniques to reveal anatomic change on the order of tens of microns may be useful for assessing tamoxifen-induced effects occurring simultaneously elsewhere in the brain, particularly since the presence of small cups is consistent with the possibility of tamoxifen-induced astrocytic swelling. PMID:17260092

  1. FLOW (finding lasting options for women): multicentre randomized controlled trial comparing tampons with menstrual cups.

    PubMed

    Howard, Courtney; Rose, Caren Lee; Trouton, Konia; Stamm, Holly; Marentette, Danielle; Kirkpatrick, Nicole; Karalic, Sanja; Fernandez, Renee; Paget, Julie

    2011-06-01

    To determine whether menstrual cups are a viable alternative to tampons. Randomized controlled trial. Prince George, Victoria, and Vancouver, BC. A total of 110 women aged 19 to 40 years who had previously used tampons as their main method of menstrual management. Participants were randomized into 2 groups, a tampon group and a menstrual cup group. Using online diaries, participants tracked 1 menstrual cycle using their regular method and 3 menstrual cycles using the method of their allocated group. Overall satisfaction; secondary outcomes included discomfort, urovaginal infection, cost, and waste. Forty-seven women in each group completed the final survey, 5 of whom were subsequently excluded from analysis (3 from the tampon group and 2 from the menstrual cup group). Overall satisfaction on a 7-point Likert scale was higher for the menstrual cup group than for the tampon group (mean [standard deviation] score 5.4 [1.5] vs 5.0 [1.0], respectively; P=.04). Approximately 91% of women in the menstrual cup group said they would continue to use the cup and recommend it to others. Women used a median of 13 menstrual products per cycle, or 169 products per year, which corresponds to approximately 771,248,400 products used annually in Canada. Estimated cost for tampon use was $37.44 a year (similar to the retail cost of 1 menstrual cup). Subjective vaginal discomfort was initially higher in the menstrual cup group, but the discomfort decreased with continued use. There was no significant difference in physician-diagnosed urovaginal symptoms between the 2 groups. Both of the menstrual management methods evaluated were well tolerated by subjects. Menstrual cups are a satisfactory alternative to tampons and have the potential to be a sustainable solution to menstrual management, with moderate cost savings and much-reduced environmental effects compared with tampons. Trial registration number C06-0478 (ClinicalTrials.gov).

  2. Coffee and depression in Korea: the fifth Korean National Health and Nutrition Examination Survey.

    PubMed

    Park, R J; Moon, J D

    2015-04-01

    There is substantial interest in the health effects of coffee because it is the leading worldwide beverage after water. Existing literature on the connection between depression and coffee is scarce, and studies have yielded inconsistent results. The aim of this study was to examine the association between coffee consumption and depression in the Korean population. We conducted a cross-sectional study in 10,177 Korean individuals aged 20-97 years who participated in the fifth Korean National Health and Nutrition Examination Survey. Consumption of coffee and depression were assessed using a questionnaire. Multiple logistic regression analysis was used to compute odds ratios (ORs) and 95% confidence intervals (CIs) for depression. The lifetime prevalence of self-reported depression was 14.0% and that of self-reported clinical depression was 3.7%. After adjustment for potential confounders, the adjusted ORs for self-reported depression across coffee consumption categories were 1.00 (reference) for less than one cup/week, 0.84 (95% CI: 0.66, 1.07) for one to six cups/week, 0.63 (95% CI: 0.51, 0.79) for one cup/day, 0.69 (95% CI: 0.54, 0.88) for two cups/day and 0.58 (95% CI: 0.44, 0.76) for three or more cups/day (P for trend, <0.01). A similar association was observed for self-reported clinical depression, for which the multiple-adjusted ORs were 1.00 (reference) for less than one cup/week, 0.61 (95% CI: 0.40, 0.92) for one to six cups/week, 0.51 (95% CI: 0.34, 0.74) for one cup/day, 0.57 (95% CI: 0.39, 0.84) for two cups/day and 0.41 (95% CI: 0.24, 0.70) for three or more cups/day, respectively (P for trend, <0.01). These findings support a possible protective effect of coffee on the risk of depression.

  3. Cupping for chronic nonspecific neck pain: a 2-year follow-up.

    PubMed

    Lauche, Romy; Cramer, Holger; Langhorst, Jost; Dobos, Gustav

    2013-01-01

    Several trials have shown that cupping might be an effective treatment for chronic nonspecific neck pain, but little is known about the long-term effectiveness. This study aimed to investigate long-term effects of a short series of cupping; therefore additional follow-up measurements were conducted 2 years after completion of 3 studies. Participants from 3 randomized waitlist controlled trials on cupping for chronic nonspecific neck pain were followed 2 years after treatment. Outcome measures included neck pain intensity (100 mm Visual Analog Scale; VAS), functional disability (Neck Disability Index, NDI), and health-related quality of life (Short Form 36 Health Survey Questionnaire; SF-36). 133 of 150 patients had received cupping treatment and were contacted; 82 of them (61.7%) returned the follow-up questionnaires. No effect was found for neck pain intensity, but for physical function (∆ NDI: -3.15; 95% CI: -5.89; -0.41; p = 0.025) and quality of life (∆ physical component summary: 2.97; 95% CI: 0.97; 4.97; p = 0.004; ∆ bodily pain: 14.53; 95 % CI: 9.67; 19.39; p < 0.001). Mean duration of cupping effect was 8.9 ± 8.7 months with 16 patients reporting that neck pain had not yet reached the level before cupping. The majority of the patients did not continue cupping therapy, mostly due to lack of providers, costs or loss of interest. A series of cupping treatments did not influence neck pain intensity on the longer term, however significant increases were found for physical function and quality of life in patients with chronic nonspecific neck pain. Due to the considerable drop-out rate conclusions are limited. There is evidence suggesting that cupping treatment might have sustainable effects in some patients. Further randomized controlled trials with long-term follow-up are urgently needed for conclusive judgment of long-term effectiveness. © 2013 S. Karger GmbH, Freiburg.

  4. Cupping reversal in pediatric glaucoma--evaluation of the retinal nerve fiber layer and visual field.

    PubMed

    Ely, Amanda L; El-Dairi, Mays A; Freedman, Sharon F

    2014-11-01

    To identify optic nerve head (ONH) cupping reversal and associated optical coherence tomography (OCT) and Humphrey visual field changes in pediatric glaucoma. Retrospective observational case series. Sequential surgical cases of juvenile open-angle glaucoma (OAG) or primary congenital glaucoma (PCG) with sustained postoperative intraocular pressure (IOP) reduction. Group 1 had preoperative and postoperative ONH photographs and OCT; Group 2 had preoperative clinical ONH assessment and postoperative imaging. Cupping evaluation was confirmed by masked glaucoma and neuro-ophthalmology specialists. Of 80 cases, 9 eyes (9 children) met criteria for Group 1; 24 eyes (19 children) met criteria for Group 2. Group 1: Five of 9 eyes (56%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 34.2 ± 6.6 mm Hg vs 10.6 ± 4.1 mm Hg (P < .00001) and mean average retinal nerve fiber layer (RNFL) 71.0 ± 30 μm vs 62.8 ± 24 μm (P = .4), respectively. RNFL was stable in 4 of 5 eyes (all juvenile OAG), but thinned (Δ = -41 μm) in 1 eye with PCG. Humphrey visual fields (reliable in 2 of 3 eyes) showed no significant change. Group 2: Fourteen of 24 PCG eyes (58%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 36.1 ± 8.9 mm Hg vs 13.3 ± 2.1 mm Hg (P < .00001). Two eyes had thin RNFL postoperatively despite healthy-appearing ONH. Postoperative RNFL showed statistically significant linear correlation with preoperative (but not postoperative) cup-to-disc ratio. Limitations include small numbers, few reliable Humphrey visual fields, and absent preoperative imaging (Group 2). Some eyes with IOP reduction and ONH cupping reversal show continued RNFL thinning postoperatively. The preoperative ONH cup-to-disc ratio predicted the postoperative RNFL better than the postoperative "reversed and smaller" cup-to-disc ratio. Cupping reversal in pediatric glaucoma may not predict improved ONH health and deserves further study. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Phosphorus-Rich Copper Phosphide Nanowires for Field-Effect Transistors and Lithium-Ion Batteries.

    PubMed

    Li, Guo-An; Wang, Chiu-Yen; Chang, Wei-Chung; Tuan, Hsing-Yu

    2016-09-27

    Phosphorus-rich transition metal phosphide CuP2 nanowires were synthesized with high quality and high yield (∼60%) via the supercritical fluid-liquid-solid (SFLS) growth at 410 °C and 10.2 MPa. The obtained CuP2 nanowires have a high aspect ratio and exhibit a single crystal structure of monoclinic CuP2 without any impurity phase. CuP2 nanowires have progressive improvement for semiconductors and energy storages compared with bulk CuP2. Being utilized for back-gate field effect transistor (FET) measurement, CuP2 nanowires possess a p-type behavior intrinsically with an on/off ratio larger than 10(4) and its single nanowire electrical transport property exhibits a hole mobility of 147 cm(2) V(-1) s(-1), representing the example of a CuP2 transistor. In addition, CuP2 nanowires can serve as an appealing anode material for a lithium-ion battery electrode. The discharge capacity remained at 945 mA h g(-1) after 100 cycles, showing a good capacity retention of 88% based on the first discharge capacity. Even at a high rate of 6 C, the electrode still exhibited an outstanding result with a capacity of ∼600 mA h g(-1). Ex-situ transmission electron microscopy and CV tests demonstrate that the stability of capacity retention and remarkable rate capability of the CuP2 nanowires electrode are attributed to the role of the metal phosphide conversion-type lithium storage mechanism. Finally, CuP2 nanowire anodes and LiFePO4 cathodes were assembled into pouch-type lithium batteries offering a capacity over 60 mA h. The full cell shows high capacity and stable capacity retention and can be used as an energy supply to operate electronic devices such as mobile phones and mini 4WD cars.

  6. Prediction of specialty coffee cup quality based on near infrared spectra of green coffee beans.

    PubMed

    Tolessa, Kassaye; Rademaker, Michael; De Baets, Bernard; Boeckx, Pascal

    2016-04-01

    The growing global demand for specialty coffee increases the need for improved coffee quality assessment methods. Green bean coffee quality analysis is usually carried out by physical (e.g. black beans, immature beans) and cup quality (e.g. acidity, flavour) evaluation. However, these evaluation methods are subjective, costly, time consuming, require sample preparation and may end up in poor grading systems. This calls for the development of a rapid, low-cost, reliable and reproducible analytical method to evaluate coffee quality attributes and eventually chemical compounds of interest (e.g. chlorogenic acid) in coffee beans. The aim of this study was to develop a model able to predict coffee cup quality based on NIR spectra of green coffee beans. NIR spectra of 86 samples of green Arabica beans of varying quality were analysed. Partial least squares (PLS) regression method was used to develop a model correlating spectral data to cupping score data (cup quality). The selected PLS model had a good predictive power for total specialty cup quality and its individual quality attributes (overall cup preference, acidity, body and aftertaste) showing a high correlation coefficient with r-values of 90, 90,78, 72 and 72, respectively, between measured and predicted cupping scores for 20 out of 86 samples. The corresponding root mean square error of prediction (RMSEP) was 1.04, 0.22, 0.27, 0.24 and 0.27 for total specialty cup quality, overall cup preference, acidity, body and aftertaste, respectively. The results obtained suggest that NIR spectra of green coffee beans are a promising tool for fast and accurate prediction of coffee quality and for classifying green coffee beans into different specialty grades. However, the model should be further tested for coffee samples from different regions in Ethiopia and test if one generic or region-specific model should be developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study.

    PubMed

    Yamada, Kazuki; Endo, Hirosuke; Tetsunaga, Tomonori; Miyake, Takamasa; Sanki, Tomoaki; Ozaki, Toshifumi

    2018-01-01

    The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation in computed tomography (CT)-based 2D-3D (two-dimensional to three-dimensional) matched navigation. In a prospective, randomized controlled study, 80 hips including 44 with developmental dysplasia of the hips were divided into a CT-based 2D-3D matched navigation group (2D-3D group) and a paired-point matched navigation group (PPM group). The accuracy of cup orientation (absolute difference between the intraoperative record and the postoperative measurement) was compared between groups. Additionally, multiple logistic regression analysis was performed to evaluate patient factors affecting the accuracy of cup orientation in each navigation. The accuracy of cup inclination was 2.5° ± 2.2° in the 2D-3D group and 4.6° ± 3.3° in the PPM group (P = .0016). The accuracy of cup anteversion was 2.3° ± 1.7° in the 2D-3D group and 4.4° ± 3.3° in the PPM group (P = .0009). In the PPM group, the presence of roof osteophytes decreased the accuracy of cup inclination (odds ratio 8.27, P = .0140) and the absolute value of pelvic tilt had a negative influence on the accuracy of cup anteversion (odds ratio 1.27, P = .0222). In the 2D-3D group, patient factors had no effect on the accuracy of cup orientation. The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors. It is a useful system for even severely deformed pelvises such as developmental dysplasia of the hips. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images

    NASA Astrophysics Data System (ADS)

    Hatanaka, Yuji; Noudo, Atsushi; Muramatsu, Chisako; Sawada, Akira; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2010-03-01

    Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.

  9. Splash-cup plants accelerate raindrops to disperse seeds.

    PubMed

    Amador, Guillermo J; Yamada, Yasukuni; McCurley, Matthew; Hu, David L

    2013-02-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6-18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle.

  10. Burns induced by cupping therapy in a burn center in northeast china.

    PubMed

    Jing-Chun, Zhao; Jia-Ao, Yu; Chun-Jing, Xian; Kai, Shi; Lai-Jin, Lu

    2014-07-01

    Cupping therapy as a curative skill has been developed and applied throughout history. Despite reports of adverse effects, this therapy is considered to be relatively safe with no systemic reviews documenting negative side effects. The aim of this study was to explore methods that avoid the adverse effects sometimes associated with this therapy. Clinical records of 14 outpatients and inpatients that visited the First Hospital of Jilin University (Changchun, China) for management of burn injuries caused by cupping therapy were retrospectively reviewed. Characteristics, history of injury, and treatment of each patient was collected and analyzed. Burn injury induced by cupping therapy was not uncommon. Most of the injuries were mild to moderate and cured by conservative methods without severe complications. The use of wet cupping was more prevalent among injured patients than dry cupping. Cupping therapy as an ancient alternative treatment is still popular with a large number of devoted practitioners. Although there is the potential for injury during the application of this therapy, this is mostly preventable. Standardized training for health care professionals and increased the awareness among the public about the proper methods to administer this therapy to avoid adverse effects is important.

  11. A Zero-Gravity Cup for Drinking Beverages in Microgravity

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Weislogel, Mark; Concus, Paul; Finn, Robert

    2011-01-01

    To date, the method for astronauts to drink liquids in microgravity or weightless environments is to suck the liquid from a bag or pouch through a straw. A new beverage cup works in microgravity and allows astronauts to drink liquids from a cup in a manner consistent with that on Earth. The cup is capable of holding beverages with an angled channel running along the wall from the bottom to the lip. In microgravity, a beverage is placed into the cup using the galley dispenser. The angled channel acts as an open passage that contains only two sides where capillary forces move the liquid along the channel until it reaches the top lip where the forces reach an equilibrium and the flow stops. When one sips the liquid at the lip of the channel, the capillary force equilibrium is upset and more liquid flows to the lip from the reservoir at the bottom to re-establish the equilibrium. This sipping process can continue until the total liquid contents of the cup is consumed, leaving only a few residual drops about the same quantity as in a ceramic cup when it is drunk dry on Earth.

  12. Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

    PubMed

    Salemyr, Mats; Muren, Olle; Eisler, Thomas; Bodén, Henrik; Chammout, Ghazi; Stark, André; Sköldenberg, Olof

    2015-05-01

    The purpose of this study was to determine if a new titanium cup with increased porosity resulted in different periacetabular bone loss and migration compared to a porous coated cup. Fifty-one patients with primary hip osteoarthritis were randomized to either a cup with porous titanium construct backside (porous titanium group, n = 25) or a conventional porous coated titanium cup (control group, n = 26). The primary outcome variable was change in periacetabular bone mineral density two years after surgery measured with dual energy X-ray absorptiometry (DXA). Secondary outcomes were implant fixation measured with radiostereometry (RSA) and clinical outcome scores. The pattern of bone remodelling was similar in the two groups with almost complete restoration to baseline values. BMD diminished in the two proximal zones and increased in the two distal zones. After minimal migration up to six months all implants in both groups became stable. We found no difference between the two groups in clinical outcome scores. In this prospective, randomized, controlled trial on a new porous titanium cup we found, compared to the control group, no clinically relevant differences regarding periacetabular bone preservation, implant fixation or clinical outcome up to two years postoperatively.

  13. Rising to the challenge: Deep acting is more beneficial when tasks are appraised as challenging.

    PubMed

    Huang, Jason L; Chiaburu, Dan S; Zhang, Xin-an; Li, Ning; Grandey, Alicia A

    2015-09-01

    Cumulative research indicates that deep acting has a nonsignificant relationship with employee exhaustion, despite arguments that deep acting can be beneficial. To illuminate when deep acting leads to more positive employee outcomes, we draw on the resource conservation perspective to propose a within-individual model of deep acting that focuses on service employees' daily fluctuation of emotional labor and emotional exhaustion. Specifically, we propose that the ongoing experience of felt challenge is a within-person boundary condition that moderates deep acting's relationship with emotional exhaustion, and model emotional exhaustion as a mediating mechanism that subsequently predicts momentary job satisfaction and daily customer conflict handling. Using an experience sampling design, we collected data from 84 service employees over a 3-week period. Deep acting was less emotionally exhausting for service providers when they saw their tasks as more challenging. Furthermore, emotional exhaustion mediated the deep acting by felt challenge interaction effect on momentary job satisfaction and daily customer conflict handling. The findings contribute to a better understanding of the deep acting experience at work, while highlighting customer conflict handling as a key behavioral outcome of emotional labor. (c) 2015 APA, all rights reserved).

  14. Cheaper Custom Shielding Cups For Arc Welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.

    1992-01-01

    New way of making special-purpose shielding cups for gas/tungsten arc welding from hobby ceramic greatly reduces cost. Pattern machined in plastic. Plaster-of-paris mold made, and liquid ceramic poured into mold. Cost 90 percent less than cup machined from lava rock.

  15. World cup soccer players tend to be born with sun and moon in adjacent zodiacal signs

    PubMed Central

    Verhulst, J

    2000-01-01

    The ecliptic elongation of the moon with respect to the sun does not show uniform distribution on the birth dates of the 704 soccer players selected for the 1998 World Cup. However, a uniform distribution is expected on astronomical grounds. The World Cup players show a very pronounced tendency (p = 0.00001) to be born on days when the sun and moon are in adjacent zodiacal signs. Key Words: soccer; World Cup; astrology; moon PMID:11131239

  16. The geochemistry of deep-sea coral skeletons: a review of vital effects and applications for palaeoceanography

    USGS Publications Warehouse

    Robinson, Laura F.; Adkins, Jess F.; Frank, Norbert; Gagon, Alexander C.; Prouty, Nancy G.; Roark, E. Brendan; van de Flierdt, Tina

    2014-01-01

    Deep-sea corals were discovered over a century ago, but it is only over recent years that focused efforts have been made to explore the history of the oceans using the geochemistry of their skeletal remains. They offer a promising archive of past oceanic environments given their global distribution, layered growth patterns, longevity and preservation as well as our ability to date them using radiometric techniques. This paper provides an overview of the current state-of-the-art in terms of geochemical approaches to using deep-sea coral skeletons to explore the history of the ocean. Deep-sea coral skeletons have a wide array of morphologies (e.g. solitary cup corals, branching colonial corals) and materials (calcite, aragonite and proteins). As such their biomineralization strategies are diverse, leading to complex geochemistry within coral skeletons. Notwithstanding these complications, progress has been made on developing methods for reconstructing the oceanographic environment in the past using trace elements and isotopic methods. Promising approaches within certain coral groups include clumped isotopes and Mg/Li for temperature reconstructions, boron isotopes and radiocarbon for carbon cycling, εNd, and radiocarbon for circulation studies and δ15N, P/Ca and Ba/Ca for nutrient tracer studies. Likewise there is now a range of techniques for dating deep-sea corals skeletons (e.g. U-series, radiocarbon), and determining their growth rates (e.g. radiocarbon and 210Pb). Dating studies on historic coral populations in the Atlantic, Southern Ocean and Pacific point to climate and environmental changes being dominant controls on coral populations over millennial and orbital timescales. This paper provides a review of a range of successes and promising approaches. It also highlights areas in which further research would likely provide new insights into biomineralization, palaeoceanography and distribution of past coral populations.

  17. Formability of dual-phase steels in deep drawing of rectangular parts: Influence of blank thickness and die radius

    NASA Astrophysics Data System (ADS)

    López, Ana María Camacho; Regueras, José María Gutiérrez

    2017-10-01

    The new goals of automotive industry related with environment concerns, the reduction of fuel emissions and the security requirements have driven up to new designs which main objective is reducing weight. It can be achieved through new materials such as nano-structured materials, fibre-reinforced composites or steels with higher strength, among others. Into the last group, the Advance High Strength Steels (AHSS) and particularly, dual-phase steels are in a predominant situation. However, despite of their special characteristics, they present issues related to their manufacturability such as springback, splits and cracks, among others. This work is focused on the deep drawing processof rectangular shapes, a very usual forming operation that allows manufacturing several automotive parts like oil pans, cases, etc. Two of the main parameters in this process which affect directly to the characteristics of final product are blank thickness (t) and die radius (Rd). Influence of t and Rd on the formability of dual-phase steels has been analysed considering values typically used in industrial manufacturing for a wide range of dual-phase steels using finite element modelling and simulation; concretely, the influence of these parameters in the percentage of thickness reduction pt(%), a quite important value for manufactured parts by deep drawing operations, which affects to its integrity and its service behaviour. Modified Morh Coulomb criteria (MMC) has been used in order to obtain Fracture Forming Limit Diagrams (FFLD) which take into account an important failure mode in dual-phase steels: shear fracture. Finally, a relation between thickness reduction percentage and studied parameters has been established fordual-phase steels, obtaining a collection of equations based on Design of Experiments (D.O.E) technique, which can be useful in order to predict approximate results.

  18. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT.

    PubMed

    Knight, O'Rese J; Girkin, Christopher A; Budenz, Donald L; Durbin, Mary K; Feuer, William J

    2012-03-01

    To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.

  19. Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT

    PubMed Central

    Knight, O’Rese J.; Girkin, Christopher A.; Budenz, Donald L.; Durbin, Mary K.; Feuer, William J.

    2017-01-01

    Objective To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. Methods In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. Results The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P≤.005) except rim area (P=.22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r2=0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. Conclusions There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups. PMID:22411660

  20. Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements.

    PubMed

    Vogel, Danny; Rathay, Andreas; Teufel, Stephanie; Ellenrieder, Martin; Zietz, Carmen; Sander, Manuela; Bader, Rainer

    2017-01-01

    In THA a sufficient primary implant stability is the precondition for successful secondary stability. Industrial foams of different densities have been used for primary stability investigations. The aim of this study was to analyse and compare the insertion behaviour of threaded and press-fit cups in vivo and ex vivo using bone substitutes with various densities. Two threaded (Bicon Plus®, Trident® TC) and one press-fit cup (Trident PSL®) were inserted by orthopaedic surgeons (S1, S2) into 10, 20 and 31 pcf blocks, using modified surgical instruments allowing measurements of the insertion forces and torques. Furthermore, the insertion behaviour of two cups were analysed intraoperatively. Torques for the threaded cups increased while bone substitute density increased. Maximum insertion torques were observed for S2 with 102 Nm for the Bicon Plus® in 20 pcf blocks and 77 Nm for the Trident® TC in 31 pcf blocks, which compares to the in vivo measurement (85 Nm). The average insertion forces for the press-fit cup varied from 5.2 to 6.8 kN (S1) and 7.2-11.5 kN (S2) ex vivo. Intraoperatively an average insertion force of 8.0 kN was determined. Implantation behaviour was influenced by acetabular cup design, bone substitute and experience of the surgeon. No specific density of bone substitute could be favoured for ex vivo investigations on the implantation behaviour of acetabular cups. The use synthetic bone blocks of high density (31 pcf) led to problems regarding cup orientation and seating. Therefore, bone substitutes used should be critically scrutinized in terms of the comparability to the in vivo situation.

  1. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  2. All dual mobility cups are not the same.

    PubMed

    Aslanian, Thierry

    2017-03-01

    Although the natural history of dual mobility has been exclusively borne for 20 years by a single company (due to industrial ownership), the concept has undeniably been very widely popularised with nearly 40 cups on the French market which should be regarded as a weight bearing surface, both broadly and in their own right. However, within the same original idea, these implants are not all identical (design, material, fixation ect.).The aim of this work is to propose a classification of different dual mobility cups by distinguishing between thegeneral characteristics of a conventional cup and those particular to this type of implant. By comparison with a standard metal-back cup, dual mobility is based on at least one additional interface corresponding to the mobility of the polyethylene insert in the concavity of the acetabular cup called the outersurface. Design, constitutive material, fixation of the cup and characteristics of the retentive insert are analysed through the published results. The complications associated, in particular, the intraprosthetic dislocation and to a lesser extent fixation failures undoubtedly condemned the dissemination of the dual mobility concept, as witnessed by the fact that despite the precedence of this 40-year old concept, the overriding majority of publications (more than 95%) have only appeared in the last ten years. The latest generation of dual mobility cups combines: 1) a cast chrome-cobalt alloy cup covered with a bilayer coating of porous titanium and hydroxyapatite for long-term press-fit fixation to 2) an insert designed to eliminate all of the risks of intraprosthetic dislocation, whilst keeping all of the elasticity properties of the polyethylene, which has demonstrated its medium and long term effectiveness on preventing instability by overcoming other complications.

  3. Early migration characteristics of a 180° porous-coated cup with 1-mm press fit.

    PubMed

    Stihsen, Christoph; Rath, Christopher; Radl, Roman; Saalabian, Ali A; Materna, Wilfried; Rehak, Peter; Windhager, Reinhard

    2013-05-01

    Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component. We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey. The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down. Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.

  4. Effects of Cupping Therapy in Amateur and Professional Athletes: Systematic Review of Randomized Controlled Trials.

    PubMed

    Bridgett, Rhianna; Klose, Petra; Duffield, Rob; Mydock, Suni; Lauche, Romy

    2018-03-01

    Despite the recent re-emergence of the process of cupping by athletes, supporting evidence for its efficacy and safety remains scarce. This systematic review aims to summarize the evidence of clinical trials on cupping for athletes. SCOPUS, Cochrane Library, PubMed, AMED, and CNKI databases were searched from their inception to December 10, 2016. Randomized controlled trials on cupping therapy with no restriction regarding the technique, or cointerventions, were included, if they measured the effects of cupping compared with any other intervention on health and performance outcomes in professionals, semi-professionals, and leisure athletes. Data extraction and risk of bias assessment using the Cochrane Risk of Bias Tool were conducted independently by two pairs of reviewers. Eleven trials with n = 498 participants from China, the United States, Greece, Iran, and the United Arab Emirates were included, reporting effects on different populations, including soccer, football, and handball players, swimmers, gymnasts, and track and field athletes of both amateur and professional nature. Cupping was applied between 1 and 20 times, in daily or weekly intervals, alone or in combination with, for example, acupuncture. Outcomes varied greatly from symptom intensity, recovery measures, functional measures, serum markers, and experimental outcomes. Cupping was reported as beneficial for perceptions of pain and disability, increased range of motion, and reductions in creatine kinase when compared to mostly untreated control groups. The majority of trials had an unclear or high risk of bias. None of the studies reported safety. No explicit recommendation for or against the use of cupping for athletes can be made. More studies are necessary for conclusive judgment on the efficacy and safety of cupping in athletes.

  5. The effectiveness of wet cupping vs. venesection on arterial O2 saturation level of cigarette smokers: A randomized controlled clinical trial

    PubMed Central

    D, Hekmatpou; L, Moeini; S, Haji-Nadali

    2013-01-01

    Objective: Wet cupping is a traditional bloodletting method recommended for controlling of respiratory disease complications. This study aimed to compare the efficacy of wet cupping vs. venesection on arterial O2 saturation level of smokers. Methods: This is a randomized controlled clinical trial which started with simple sampling of smokers. After administering spirometery, participants (N = 110 male smokers) with positive pulmonary function test (PFT), who manifested Chronic Obstructive Pulmonary Disease (COPD), were randomly assigned to intervention and control groups. The two groups were assessed in terms of demographic data, rate of hemoglobin (Hb), hematocrit (Hct), and arterial O2 saturation. Then, the intervention participants underwent wet cupping whereas venesection was performed on the control participants. At four stages after the two treatments, pulse oximetery was performed. Data was analyzed using SPSS (Version 17). Results: Result shows that mean arterial O2 sat level increased at three stages, namely before, immediately after, and 6 and 12 hrs after these two treatments (p ≤ 0.001). This indicates that wet cupping and venesection alike were effective on O2 sat level in the two groups, but the increasing pattern was maintained 12 hrs afterward only in those participants who had received wet cupping (p ≤ 0.001). Moreover, the results of repeated measure ANOVA between the two groups at the four stages showed that there were significant differences between the means of O2 saturation level at the 6- and 12-hrs stages (F = 66.92, p ≤ 0.001). Conclusion: Wet cupping caused a continued O2 saturation in the intervention group even up to 12 hrs afterward. Participants expressed liveliness and improved respiration after wet cupping. Therefore, wet cupping is recommended for promoting the health of cigarette smokers. PMID:24550951

  6. Can an agent’s false belief be corrected by an appropriate communication? Psychological reasoning in 18-month-old infants

    PubMed Central

    Song, Hyun-joo; Onishi, Kristine H.; Baillargeon, Renée; Fisher, Cynthia

    2008-01-01

    Do 18-month-olds understand that an agent’s false belief can be corrected by an appropriate, though not an inappropriate, communication? In Experiment 1, infants watched a series of events involving two agents, a ball, and two containers: a box and a cup. To start, agent1 played with the ball and then hid it in the box, while agent2 looked on. Next, in agent1’s absence, agent2 moved the ball from the box to the cup. When agent1 returned, agent2 told her “The ball is in the cup!” (informative-intervention condition) or “I like the cup!” (uninformative-intervention condition). During test, agent1 reached for either the box (box event) or the cup (cup event). In the informative-intervention condition, infants who saw the box event looked reliably longer than those who saw the cup event; in the uninformative-intervention condition, the reverse pattern was found. These results suggest that infants expected agent1’s false belief about the ball’s location to be corrected when she was told “The ball is in the cup!”, but not “I like the cup!”. In Experiment 2, agent2 simply pointed to the ball’s new location, and infants again expected agent1’s false belief to be corrected. These and control results provide additional evidence that infants in the second year of life can attribute false beliefs to agents. In addition, the results suggest that by 18 months of age infants expect agents’ false beliefs to be corrected by relevant communications involving words or gestures. PMID:18976745

  7. What Is the Standard Volume to Increase a Cup Size for Breast Augmentation Surgery? A Novel Three-Dimensional Computed Tomographic Approach.

    PubMed

    King, Nina-Marie; Lovric, Vedran; Parr, William C H; Walsh, W R; Moradi, Pouria

    2017-05-01

    Breast augmentation surgery poses many challenges, and meeting the patient's expectations is one of the most important. Previous reports equate 100 cc to a one-cup-size increase; however, no studies have confirmed this between commercially available bras. The aim of this study was to identify the volume increase between cup sizes across different brands and the relationship with implant selection. Five bra cup sizes from three different companies were analyzed for their volume capacity. Three methods were used to calculate the volume of the bras: (1) linear measurements; (2) volume measurement by means of water displacement; and (3) volume calculation after three-dimensional reconstruction of serial radiographic data (computed tomography). The clinical arm consisted of 79 patients who underwent breast augmentation surgery from February 1, 2014, to June 30, 2016. Answers from a short questionnaire in combination with the implant volume were analyzed. Across all three brands, the interval volume increase varied between sizes, but not all were above 100 cc. There was some variation in the volume capacity of the same cup size among the different brands. The average incremental increase in bra cup size across all three brands in the laboratory arm was 135 cc. The mean volume increase per cup size was 138.23 cc in the clinical arm. This article confirms that there is no standardization within the bra manufacturing industry. On the basis of this study, patients should be advised that 130 to 150 cc equates to a one-cup-size increase. Bras with narrower band widths need 130 cc and wider band widths require 150 cc to increase one cup size.

  8. Effect of cup feeding and bottle feeding on breastfeeding in late preterm infants: a randomized controlled study.

    PubMed

    Yilmaz, Gonca; Caylan, Nilgun; Karacan, Can Demir; Bodur, İlknur; Gokcay, Gulbin

    2014-05-01

    Cup feeding has been used as an alternative feeding method for preterm infants. The purpose of this study was to determine the effect of bottle and cup feeding on exclusive breastfeeding rates at hospital discharge and 3 and 6 months post-discharge in late preterm infants. Included in the study were preterm infants of 32 to 35 weeks' gestation fed only by intermittent gastric tube at the time of recruitment; 522 infants were randomly assigned to 2 groups: the cup-fed group (n = 254) and bottle-fed group (n = 268). Main outcomes were prevalence of exclusive breastfeeding at discharge and 3 and 6 months after discharge, and length of hospital stay. Infants randomized to cup versus bottle feeding were more likely to be exclusively breastfed at discharge home (relative risk [RR], 1.58; 95% confidence interval [CI], 1.36-1.83), 3 months after discharge (RR, 1.64; 95% CI, 1.42-1.89), and 6 months after discharge (RR, 1.36; 95% CI, 1.14-1.63). There was no significant difference between groups for length of hospital stay. The mean hospital stay was 25.96 ± 2.20 days in the bottle-fed group and 25.68 ± 2.22 days in the cup-fed group. There was no significant difference between groups for time spent feeding, feeding problems, or weight gain in hospital. Cup feeding significantly increased the likelihood of late preterm infants being exclusively breastfed at discharge and 3 and 6 months after discharge, and cup feeding did not increase the length of hospital stay. Overall, we recommend cup feeding as a transitional method prior to breastfeeding for late preterm infants during hospitalization.

  9. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    PubMed

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P <.0001). Significant variabilities in specimen size (P = .001), the presence of intact urothelium (P = .008), and crush artifact (P = .028) were found among the biopsy devices. The quality of specimens from backloaded cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Targeting a Hidden Enemy: Pyriproxyfen Autodissemination Strategy for the Control of the Container Mosquito Aedes albopictus in Cryptic Habitats

    PubMed Central

    Suman, Devi Shankar; Wang, Yi; Unlu, Isik; Williges, Eric; Williams, Gregory M.; Gaugler, Randy

    2016-01-01

    Background The Asian tiger mosquito, Aedes albopictus, is a vector of dengue, Chikungunya, and Zika viruses. This mosquito inhabits a wide range of artificial water-holding containers in urban and suburban areas making it difficult to control. We tested the hypothesis that female-driven autodissemination of an insect growth regulator could penetrate cryptic oviposition habitats difficult to treat with conventional insecticidal sprays. Methodology Oviposition preferences of Ae. albopictus females for open and cryptic cups were tested in semi-field experiments. Two conventional larvicidal sprayers were tested to determine droplet penetration and larvicidal efficacy in open and cryptic habitats using Bacillus thuringiensis var. israelensis (Bti) in the field. Finally, the efficacy of pyriproxyfen autodissemination stations was assessed in cryptic and open cups in residential areas during 2013 and 2014. Principal Findings Gravid females strongly preferred cryptic (53.1±12.9 eggs/cup) over open (10.3±4.3 eggs/cup) cups for oviposition. Cryptic cups showed limited droplet penetration and produced 0.1–0.3% larval mortality with a conventional backpack and low-volume sprays of Bti. The autodissemination stations effectively contaminated these cryptic cups (59.3–84.6%) and produced 29.7–40.8% pupal mortality during 2013–2014. Significant pupal mortality was also observed in open cups. Conclusions The autodissemination station effectively exploits the oviposition behavior of wild gravid females to deliver pyriproxyfen to targeted oviposition habitats. Although the pupal mortality in cryptic cups was relatively lower than expected for the effective vector control. Autodissemination approach may be a suitable supporting tool to manage Ae. albopictus immatures in the cryptic habitats those are less accessible to conventional larvicidal sprays. PMID:28033379

  11. EOS-based cup navigation: Randomised controlled trial in 78 total hip arthroplasties.

    PubMed

    Verdier, N; Billaud, A; Masquefa, T; Pallaro, J; Fabre, T; Tournier, C

    2016-06-01

    Minimising the risk of cup implantation outside the safe zone is among the objectives of navigation during total hip arthroplasty (THA). However, given the technical challenges raised by navigation when the patient is lying on the side, many surgeons still use the freehand technique. We conducted a randomised controlled trial to evaluate the new navigation system NAVEOS in the iliac plane, which is easily identified in the lateral decubitus position, with the objective of determining whether NAVEOS navigation decreased the frequency of cup implantation outside the safe zone compared to freehand cup positioning, without increasing the operative time or the frequency of complications. NAVEOS navigation decreases the frequency of cup positioning outside the safe zone compared to freehand positioning. This randomised controlled trial compared cup positioning using NAVEOS navigation versus the freehand technique in patients undergoing primary THA. The safe zone was defined according to Lewinnek as 15±10° of radiological anteversion and 40±10° of radiological inclination. Cup position parameters were measured on computed tomography images obtained 3months after THA. The images were read by two independent observers who were blinded to group assignment. The primary evaluation criterion was cup position within the safe zone. A 1:1 randomisation scheme was used to assign 78 patients (mean age, 68years; age range, 44-91years) to NAVEOS navigation or freehand cup positioning. The two groups were comparable for age, gender distribution, body mass index, and preoperative functional scores. In the NAVEOS group, navigation was discontinued prematurely in 6 patients, because of technical difficulties (n=2) or a marked discrepancy with clinical findings (n=4); however, the intention-to-treat approach was used for the analysis. The proportion of cups in the safe zone was 67% (28/39) in the NAVEOS group and 38% (17/39) in the freehand group (P=0.012). Anteversion was within the 5-25° range for 72% (28/39) cups in the NAVEOS group and 46% (18/39) in the freehand group (P=0.021). Inclination was within the 30-50° range for 95% (37/39) of cups with NAVEOS navigation and 85% (33/39) with freehand positioning (P=0.135). The odds ratio for cup implantation outside the safe zone was significantly lower with NAVEOS compared to freehand positioning (0.54; 95% confidence interval, 0.31-0.91). Mean operative time was 74 (range, 45-115) minutes with NAVEOS navigation and 70 (range, 40-105) minutes with freehand positioning (P=0.382). Complications consisted of 1 case each of anterior dislocation and infection, both in the freehand group. Compared to freehand positioning, NAVEOS navigation significantly lowered the risk of cup positioning outside the safe zone, chiefly via improved achievement of the anteversion target. NAVEOS was not associated with increases in operative time or morbidity. II, randomised controlled trial with limited statistical power. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Influence of small-scale turbulence on cup anemometer calibrations

    NASA Astrophysics Data System (ADS)

    Marraccini, M.; Bak-Kristensen, K.; Horn, A.; Fifield, E.; Hansen, S. O.

    2017-11-01

    The paper presents and discusses the calibration results of cup anemometers under different levels of small-scale turbulence. Small-scale turbulence is known to govern the curvature of shear layers around structures and is not related to the traditional under and over speeding of cup anemometers originating from large-scale turbulence components. The paper has shown that the small-scale turbulence has a significant effect on the calibration results obtained for cup anemometers. At 10m/s the rotational speed seems to change by approx. 0.5% due to different simulations of the small-scale turbulence. The work which this paper is based on, is part of the TrueWind research project, aiming to increase accuracy of mast top-mounted cup anemometer measurements.

  13. A new technique for radiographic measurement of acetabular cup orientation.

    PubMed

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  14. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

    PubMed

    Badhe, Sachin; Livesley, Peter

    2006-02-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7-12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup . The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92-97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61-78%) and survival of the acetabular liner for wear was 62% (95% CI: 48-74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups.

  15. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)

    PubMed Central

    Livesley, Peter

    2005-01-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7–12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup .The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92–97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61–78%) and survival of the acetabular liner for wear was 62% (95% CI: 48–74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups. PMID:16283307

  16. Optic cup segmentation from fundus images for glaucoma diagnosis.

    PubMed

    Hu, Man; Zhu, Chenghao; Li, Xiaoxing; Xu, Yongli

    2017-01-02

    Glaucoma is a serious disease that can cause complete, permanent blindness, and its early diagnosis is very difficult. In recent years, computer-aided screening and diagnosis of glaucoma has made considerable progress. The optic cup segmentation from fundus images is an extremely important part for the computer-aided screening and diagnosis of glaucoma. This paper presented an automatic optic cup segmentation method that used both color difference information and vessel bends information from fundus images to determine the optic cup boundary. During the implementation of this algorithm, not only were the locations of the 2 types of information points used, but also the confidences of the information points were evaluated. In this way, the information points with higher confidence levels contributed more to the determination of the final cup boundary. The proposed method was evaluated using a public database for fundus images. The experimental results demonstrated that the cup boundaries obtained by the proposed method were more consistent than existing methods with the results obtained by ophthalmologists.

  17. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    PubMed

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  18. Optic cup segmentation from fundus images for glaucoma diagnosis

    PubMed Central

    Hu, Man; Zhu, Chenghao; Li, Xiaoxing; Xu, Yongli

    2017-01-01

    ABSTRACT Glaucoma is a serious disease that can cause complete, permanent blindness, and its early diagnosis is very difficult. In recent years, computer-aided screening and diagnosis of glaucoma has made considerable progress. The optic cup segmentation from fundus images is an extremely important part for the computer-aided screening and diagnosis of glaucoma. This paper presented an automatic optic cup segmentation method that used both color difference information and vessel bends information from fundus images to determine the optic cup boundary. During the implementation of this algorithm, not only were the locations of the 2 types of information points used, but also the confidences of the information points were evaluated. In this way, the information points with higher confidence levels contributed more to the determination of the final cup boundary. The proposed method was evaluated using a public database for fundus images. The experimental results demonstrated that the cup boundaries obtained by the proposed method were more consistent than existing methods with the results obtained by ophthalmologists. PMID:27764542

  19. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  20. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    PubMed

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P < .001), psoas tendinopathy (P = .02), and iliopsoas bursitis (P < .001) were significantly associated with iliopsoas impingement syndrome, the latter reported with specificity of 100%. In the sagittal plane at the level of the psoas tendon, a maximum sagittal length of greater than 5 mm and a posteroanterior cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  1. Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position.

    PubMed

    Brodt, Steffen; Nowack, Dimitri; Jacob, Benjamin; Krakow, Linda; Windisch, Christoph; Matziolis, Georg

    2017-09-01

    Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup. Strong traction caused by retractors leads to iatrogenic pelvic lift and can thus be partly responsible for cup malpositioning. The objective of this study was to investigate such factors that influence pelvic lift. The dynamic movement of the pelvis was measured during implantation of THA in 67 patients. This was done by measuring the acceleration using the SensorLog app on a smartphone. At its maximum, the pelvis was lifted by an average of 6.7°. When impacting the press-fit cup, the surgical side was raised by 4.4° compared with the time of skin incision. This lift at the time of cup implantation correlates significantly with the body mass index and the patient's abdominal and pelvic circumference. Every surgeon performing THA must be aware of the pelvic lift during an operation. Especially in patients with a high body mass index, a large abdominal circumference, or a large pelvic circumference, there is an increased risk of malpositioning of the acetabular cup. When impacting the cup, we recommend releasing the traction of the retractor, so that the pelvis can tilt back into its natural position, and thus, the anticipated cup positioning can be implemented as exactly as possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. [Acetabular Osteolysis in Total Hip Replacement - When to Retain the Cup?].

    PubMed

    Lutz, B; Faschingbauer, M; Bieger, R; Reichel, H; Kappe, T

    2016-08-01

    Periacetabular osteolysis is a frequent long-term complication of cementless total hip arthroplasty. The decision whether to retain or to revise a cup in the presence of osteolysis remains a challenge. The options are regular clinical and radiological check-ups, isolated liner exchange with and without bone grafting, and complete cup revision. Thorough preoperative diagnostics, including a medical history, examination and imaging, are mandatory for correct decision making. In most patients, computed tomography is useful to assess periacetabular osteolysis. If the cup is well-fixed and positioned in an asymptomatic patient without progressive osteolysis and no implant defect or higher grade polyethylene wear and no signs of infection, continuous clinical and radiological monitoring is preferred. If imaging reveals cup loosening, malposition, osteolysis localised in a weight-bearing area, imminent or present periprosthetic fractures, rapid progressive osteolysis, implant defects or massive inlay wear, surgical treatment may be preferred. Cup revision is usually performed in such patients. If the cup is well-positioned and well-fixed in the X-ray, the procedure has to be discussed with the patient individually. Apart from patient-specific risk factors, the risk of further progression has to be assessed. Isolated liner exchange can be performed if the patient is asymptomatic and the cup proves to be stable intraoperatively. It is still unclear whether filling osteolyses through screw holes or osseous windows is of long-term benefit. Georg Thieme Verlag KG Stuttgart · New York.

  3. CUP promotes deadenylation and inhibits decapping of mRNA targets

    PubMed Central

    Igreja, Catia; Izaurralde, Elisa

    2011-01-01

    CUP is an eIF4E-binding protein (4E-BP) that represses the expression of specific maternal mRNAs prior to their posterior localization. Here, we show that CUP employs multiple mechanisms to repress the expression of target mRNAs. In addition to inducing translational repression, CUP maintains mRNA targets in a repressed state by promoting their deadenylation and protects deadenylated mRNAs from further degradation. Translational repression and deadenylation are independent of eIF4E binding and require both the middle and C-terminal regions of CUP, which collectively we termed the effector domain. This domain associates with the deadenylase complex CAF1–CCR4–NOT and decapping activators. Accordingly, in isolation, the effector domain is a potent trigger of mRNA degradation and promotes deadenylation, decapping and decay. However, in the context of the full-length CUP protein, the decapping and decay mediated by the effector domain are inhibited, and target mRNAs are maintained in a deadenylated, repressed form. Remarkably, an N-terminal regulatory domain containing a noncanonical eIF4E-binding motif is required to protect CUP-associated mRNAs from decapping and further degradation, suggesting that this domain counteracts the activity of the effector domain. Our findings indicate that the mode of action of CUP is more complex than previously thought and provide mechanistic insight into the regulation of mRNA expression by 4E-BPs. PMID:21937713

  4. Authenticity and autonomy in deep-brain stimulation.

    PubMed

    Wardrope, Alistair

    2014-08-01

    Felicitas Kraemer draws on the experiences of patients undergoing deep-brain stimulation (DBS) to propose two distinct and potentially conflicting principles of respect: for an individual's autonomy (interpreted as mental competence), and for their authenticity. I argue instead that, according to commonly-invoked justifications of respect for autonomy, authenticity is itself in part constitutive of an analysis of autonomy worthy of respect; Kraemer's argument thus highlights the shortcomings of practical applications of respect for autonomy that emphasise competence while neglecting other important dimensions of autonomy such as authenticity, since it shows that competence alone cannot be interpreted as a reliable indicator of an individual's capacity for exercising autonomy. I draw from relational accounts to suggest how respect for a more expansive conception of autonomy might be interpreted for individuals undergoing DBS and in general. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Evaluation of wet-cupping therapy for persistent non-specific low back pain: a randomised, waiting-list controlled, open-label, parallel-group pilot trial.

    PubMed

    Kim, Jong-In; Kim, Tae-Hun; Lee, Myeong Soo; Kang, Jung Won; Kim, Kun Hyung; Choi, Jun-Yong; Kang, Kyung-Won; Kim, Ae-Ran; Shin, Mi-Suk; Jung, So-Young; Choi, Sun-mi

    2011-06-10

    Persistent non-specific low back pain (PNSLBP) is one of the most frequently experienced types of back pain around the world. Wet-cupping is a common intervention for various pain conditions, especially in Korea. In this context, we conducted a pilot study to determine the effectiveness and safety of wet-cupping treatment for PNSLBP. We recruited 32 participants (21 in the wet-cupping group and 11 in the waiting-list group) who had been having PNSLBP for at least 3 months. The participants were recruited at the clinical research centre of the Korea Institute of Oriental Medicine, Korea. Eligible participants were randomly allocated to wet-cupping and waiting-list groups. Following the practice of traditional Korean medicine, the treatment group was provided with wet-cupping treatment at two acupuncture points among the BL23, BL24 and BL25 6 times within 2 weeks. Usual care, including providing brochures for exercise, general advice for PNSLBP and acetaminophen, was allowed in both groups. Separate assessors participated in the outcome assessment. We used the 0 to 100 numerical rating scale (NRS) for pain, the McGill Pain Questionnaire for pain intensity (PPI) and the Oswestry Disability Questionnaire (ODQ), and we assessed acetaminophen use and safety issues. The results showed that the NRS score for pain decreased (-16.0 [95% CI: -24.4 to -7.7] in the wet-cupping group and -9.1 [-18.1 to -0.1] in the waiting-list group), but there was no statistical difference between the groups (p = 0.52). However, the PPI scores showed significant differences between the two groups (-1.2 [-1.6 to -0.8] for the wet-cupping group and -0.2 [-0.8 to 0.4] for the waiting-list group, p < 0.01). In addition, less acetaminophen was used in the wet-cupping group during 4 weeks (p = 0.09). The ODQ score did not show significant differences between the two groups (-5.60 [-8.90 to -2.30] in the wet-cupping group and -1.8 [-5.8 to 2.2] in the waiting-list group, p = 0.14). There was no report of adverse events due to wet-cupping. This pilot study may provide preliminary data on the effectiveness and safety of wet-cupping treatments for PNSLBP. Future full-scale randomised controlled trials will be needed to provide firm evidence of the effectiveness of this intervention.

  6. Digital Peer-Support Platform (7Cups) as an Adjunct Treatment for Women With Postpartum Depression: Feasibility, Acceptability, and Preliminary Efficacy Study.

    PubMed

    Baumel, Amit; Tinkelman, Amanda; Mathur, Nandita; Kane, John M

    2018-02-13

    Peer support is considered to be an important framework of support for mothers experiencing postpartum depression (PPD); however, some barriers exist that may limit its use including peer availability and mothers' lack of time due to child care. This non-randomized study was designed to examine the feasibility, acceptance, and preliminary clinical outcomes of using 7 Cups of Tea (7Cups), a digital platform that delivers self-help tools and 24/7 emotional support delivered by trained volunteers, as an adjunct treatment for mothers diagnosed with PPD. Mothers with PPD were referred during intake to the study coach who provided guidance about 7Cups. 7Cups features included self-help tools and chats with trained volunteers who had experienced a perinatal mood disorder in their past. Acceptability was measured by examining self-reports and user engagement with the program. The primary outcome was the Edinburgh Postnatal Depression Scale (EPDS) change score between pre- and postintervention at 2 months, as collected in usual care by clinicians blinded to the study questions. Using a propensity score matching to control for potential confounders, we compared women receiving 7Cups to women receiving treatment as usual (TAU). Participants (n=19) proactively logged into 7Cups for a median of 12 times and 175 minutes. Program use was mostly through the mobile app (median of mobile use 94%) and between 18:00 and 08:00 when clinicians are unavailable (68% of total program use time). Participants chatted with volunteers for a total of 3064 minutes and have indicated in their responses 0 instances in which they felt unsafe. Intent-to-treat analysis revealed that 7Cups recipients experienced significant decreases in EPDS scores (P<.001, Cohen d=1.17). No significant difference in EPDS decrease over time was found between 7Cups and TAU, yet the effect size was medium favoring 7Cups (P=.05, Cohen d=0.58). This study supports using a computerized method to train lay people, without any in-person guidance or screening, and engage them with patients diagnosed with mental illness as part of usual care. The medium effect size (d=0.58) favoring the 7Cups group relative to TAU suggests that 7Cups might enhance treatment outcomes. A fully powered trial has to be conducted to examine this effect. ©Amit Baumel, Amanda Tinkelman, Nandita Mathur, John M Kane. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 13.02.2018.

  7. Influence of the pressure dependent coefficient of friction on deep drawing springback predictions

    NASA Astrophysics Data System (ADS)

    Gil, Imanol; Galdos, Lander; Mendiguren, Joseba; Mugarra, Endika; Sáenz de Argandoña, Eneko

    2016-10-01

    This research studies the effect of considering an advanced variable friction coefficient on the springback prediction of stamping processes. Traditional constant coefficient of friction considerations are being replaced by more advanced friction coefficient definitions. The aim of this work is to show the influence of defining a pressure dependent friction coefficient on numerical springback predictions of a DX54D mild steel, a HSLA380 and a DP780 high strength steel. The pressure dependent friction model of each material was fitted to the experimental data obtained by Strip Drawing tests. Then, these friction models were implemented in a numerical simulation of a drawing process of an industrial automotive part. The results showed important differences between defining a pressure dependent friction coefficient or a constant friction coefficient.

  8. 9 CFR 590.522 - Breaking room operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... equipment shall be rotated with clean equipment every 21/2 hours. (e) Cups shall not be filled to... blood spots, and other foreign material accidentally falling into the cups or trays shall be removed... to this section. (j) The contents of any cup or other liquid egg receptacle containing one or more...

  9. 75 FR 43150 - Marine Mammals; File Nos. 10018, 13846, 14451, 14585, 14599, 14122, 14296, and 14353

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-23

    ... of sloughed skin, photogrammetry, biopsy sampling, playback experiments, and/or suction- cup and... to individuals; (6) attachment of suction cup tags; (7) SCUBA observations; and (8) opportunistic.... Research will include vessel-based approaches: (1) to humpback whales for biological sampling, suction cup...

  10. 9 CFR 590.522 - Breaking room operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... equipment shall be rotated with clean equipment every 21/2 hours. (e) Cups shall not be filled to... blood spots, and other foreign material accidentally falling into the cups or trays shall be removed... to this section. (j) The contents of any cup or other liquid egg receptacle containing one or more...

  11. 75 FR 30421 - Central Utah Project Completion Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-01

    ... facilities of the Wasatch County Water Efficiency Project (WCWEP), Bonneville Unit, Central Utah Project (CUP... conservation and wise use of water, all of which are objectives of the CUP Completion Act. The proposed action would allow recycled water to be conveyed and used in WCWEP facilities and through exchange become CUP...

  12. A Homemade Instrument for Collecting Soil Water From Porous Ceramic Cups

    Treesearch

    M. Dean Knighton; Dwight E. Streblow

    1981-01-01

    An efficient Ceramic-Cup Water Collection Instrument (CCWCI, "quickie") is described. Soil water collection from ceramic-cup samplers may require compositing by equal volume from distantly spaced samplers, or simultaneous water collection spaced samplers, or simultaneous water collection from closely spaced samplers without compositing. All collection must...

  13. A retained menstrual cup.

    PubMed

    Day, S

    2012-05-01

    A 20-year-old woman attended a genitourinary clinic with a retained vaginal Mooncup that she had inserted the night before. A Mooncup is one type of menstrual cup. On speculum examination the device was visualized high in the vagina and the cervix appeared firmly lodged within it. The physician experienced difficulty in retrieving the cup despite following product instructions. This case highlights a new adverse event with an increasingly used sanitation product. It is important that clinicians are familiar with the cup, its removal process and are able to counsel patients with retained devices on future correct placement.

  14. Sound of a cup with and without instant coffee

    NASA Astrophysics Data System (ADS)

    Morrison, Andrew; Rossing, Thomas D.

    2002-05-01

    An empty coffee cup, like an ancient Chinese two-tone bell, emits two distinctly different tones, depending upon where it is tapped. When it is filled with hot water, and some instant coffee is added, however, a whole new set of sounds is heard when the cup is tapped. The pitch rises an octave or more as the foam clears due to the dramatic change in the speed of sound in the bubble-filled liquid. A similar, but smaller, effect was noted in beer by Bragg [The World of Sound (1968)] and in hot chocolate by Crawford [Am. J. Phys. (1982)]. We describe the modes of vibration in a coffee cup and the sound emitted by a coffee cup as filled with instant coffee as the bubble density changes.

  15. On cup anemometer rotor aerodynamics.

    PubMed

    Pindado, Santiago; Pérez, Javier; Avila-Sanchez, Sergio

    2012-01-01

    The influence of anemometer rotor shape parameters, such as the cups' front area or their center rotation radius on the anemometer's performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results were compared to the ones resulting from classical analytical models. The results clearly showed a linear dependency of both calibration constants, the slope and the offset, on the cups' center rotation radius, the influence of the front area of the cups also being observed. The analytical model of Kondo et al. was proved to be accurate if it is based on precise data related to the aerodynamic behavior of a rotor's cup.

  16. Photogrammetry experiments with a model eye.

    PubMed Central

    Rosenthal, A R; Falconer, D G; Pieper, I

    1980-01-01

    Digital photogrammetry was performed on stereophotographs of the optic nerve head of a modified Zeiss model eye in which optic cups of varying depths could be simulated. Experiments were undertaken to determine the impact of both photographic and ocular variables on the photogrammetric measurements of cup depth. The photogrammetric procedure tolerates refocusing, repositioning, and realignment as well as small variations in the geometric position of the camera. Progressive underestimation of cup depth was observed with increasing myopia, while progressive overestimation was noted with increasing hyperopia. High cylindrical errors at axis 90 degrees led to significant errors in cup depth estimates, while high cylindrical errors at axis 180 degrees did not materially affect the accuracy of the analysis. Finally, cup depths were seriously underestimated when the pupil diameter was less than 5.0 mm. Images PMID:7448139

  17. Developing a trend prediction model of subsurface damage for fixed-abrasive grinding of optics by cup wheels.

    PubMed

    Dong, Zhichao; Cheng, Haobo

    2016-11-10

    Fixed-abrasive grinding by cup wheels plays an important role in the production of precision optics. During cup wheel grinding, we strive for a large removal rate while maintaining fine integrity on the surface and subsurface layers (academically recognized as surface roughness and subsurface damage, respectively). This study develops a theoretical model used to predict the trend of subsurface damage of optics (with respect to various grinding parameters) in fixed-abrasive grinding by cup wheels. It is derived from the maximum undeformed chip thickness model, and it successfully correlates the pivotal parameters of cup wheel grinding with the subsurface damage depth. The efficiency of this model is then demonstrated by a set of experiments performed on a cup wheel grinding machine. In these experiments, the characteristics of subsurface damage are inspected by a wedge-polishing plus microscopic inspection method, revealing that the subsurface damage induced in cup wheel grinding is composed of craterlike morphologies and slender cracks, with depth ranging from ∼6.2 to ∼13.2  μm under the specified grinding parameters. With the help of the proposed model, an optimized grinding strategy is suggested for realizing fine subsurface integrity as well as high removal rate, which can alleviate the workload of subsequent lapping and polishing.

  18. Splash-cup plants accelerate raindrops to disperse seeds

    PubMed Central

    Amador, Guillermo J.; Yamada, Yasukuni; McCurley, Matthew; Hu, David L.

    2013-01-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6–18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle. PMID:23235266

  19. Evaluation of a menstrual cup to collect shed endometrium for in vitro studies.

    PubMed

    Koks, C A; Dunselman, G A; de Goeij, A F; Arends, J W; Evers, J L

    1997-09-01

    To evaluate whether a menstrual cup is a suitable instrument to collect antegradely shed endometrium for in vitro studies. A prospective, descriptive, cell biological and immunohistochemical study. Tertiary care university medical center. Nine female volunteers with regular cycles. Menstrual effluent was collected with a menstrual cup. Experience with the menstrual cup was described. Cytospin specimens, frozen sections, and cultures were prepared from the obtained menstrual tissue. The acceptability of the menstrual cup. The presence and viability of endometrial tissue was evaluated using immunohistochemical staining and culture outcome. All women except one described the menstrual cup as acceptable. Menstrual effluent contained single cells, clumps of cells, and glandlike structures. After 5 days of culture, the endometrial tissue appeared to be viable. Immunohistochemistry showed positive staining for vimentin in most cytospin specimens, in all cryostat specimens, and in 10 of 17 cultures. Cytokeratin 18 stained most cytospin specimens, all cryostat specimens, and 10 of 17 cultures. Positive staining for BW495/36 was observed in most cytospin specimens, all cryostat specimens, and 11 of 17 cultures. A menstrual cup in an acceptable instrument to collect antegradely shed menstrual tissue. Menstruum contains viable endometrial tissue that can be used for in vitro studies of endometrium and endometriosis.

  20. Numerical analysis of the change in skin color due to ecchymosis and petechiae generated by cupping: a pilot study.

    PubMed

    Kim, Soo-Byeong; Lee, Yong-Heum

    2014-12-01

    Cupping is one of the various treatment methods used in traditional oriental medicine. Cupping is also used as a diagnostic method and it may cause skin hyperpigmentation. Quantitative measurements and analysis of changes in skin color due to cupping are critical. The purpose of this study is to suggest an optical technique to visualize and identify changes in skin color due to cupping. We suggest the following analysis methods: digital color spaces [red, green, and blue (RGB) and L∗a∗b], the Erythema Index (E.I.), and the Melanin Index (M.I.). For experiments, we selected and stimulated 10 acupoints at 80 kilopascals (kPa) per minute. The RGB and L∗a∗b color spaces were observed to be decreased (p < 0.05) after cupping. The E.I. and M.I. were observed to be increased significantly (p < 0.05) after cupping. To assess various changes in skin color, we observed the changes for 72 hours. We also obtained the color changes by using the recovery pattern during the recovery period (p < 0.01). We propose that this method can be useful for visual identification and as a way to improve the identification of skin color changes. Copyright © 2014. Published by Elsevier B.V.

  1. Inferential reasoning by exclusion in children (Homo sapiens).

    PubMed

    Hill, Andrew; Collier-Baker, Emma; Suddendorf, Thomas

    2012-08-01

    The cups task is the most widely adopted forced-choice paradigm for comparative studies of inferential reasoning by exclusion. In this task, subjects are presented with two cups, one of which has been surreptitiously baited. When the empty cup is shaken or its interior shown, it is possible to infer by exclusion that the alternative cup contains the reward. The present study extends the existing body of comparative work to include human children (Homo sapiens). Like chimpanzees (Pan troglodytes) that were tested with the same equipment and near-identical procedures, children aged three to five made apparent inferences using both visual and auditory information, although the youngest children showed the least-developed ability in the auditory modality. However, unlike chimpanzees, children of all ages used causally irrelevant information in a control test designed to examine the possibility that their apparent auditory inferences were the product of contingency learning (the duplicate cups test). Nevertheless, the children's ability to reason by exclusion was corroborated by their performance on a novel verbal disjunctive syllogism test, and we found preliminary evidence consistent with the suggestion that children used their causal-logical understanding to reason by exclusion in the cups task, but subsequently treated the duplicate cups information as symbolic or communicative, rather than causal. Implications for future comparative research are discussed. 2012 APA, all rights reserved

  2. A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Xiao, Ruo-Xiu; Zhao, Zhe; Zhang, Li-Hai; Zhang, Li-Cheng; Tang, Pei-Fu

    2016-11-01

    We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. dlx and sp6-9 Control Optic Cup Regeneration in a Prototypic Eye

    PubMed Central

    Lapan, Sylvain W.; Reddien, Peter W.

    2011-01-01

    Optic cups are a structural feature of diverse eyes, from simple pit eyes to camera eyes of vertebrates and cephalopods. We used the planarian prototypic eye as a model to study the genetic control of optic cup formation and regeneration. We identified two genes encoding transcription factors, sp6-9 and dlx, that were expressed in the eye specifically in the optic cup and not the photoreceptor neurons. RNAi of these genes prevented formation of visible optic cups during regeneration. Planarian regeneration requires an adult proliferative cell population with stem cell-like properties called the neoblasts. We found that optic cup formation occurred only after migration of progressively differentiating progenitor cells from the neoblast population. The eye regeneration defect caused by dlx and sp6-9 RNAi can be explained by a failure to generate these early optic cup progenitors. Dlx and Sp6-9 genes function as a module during the development of diverse animal appendages, including vertebrate and insect limbs. Our work reveals a novel function for this gene pair in the development of a fundamental eye component, and it utilizes these genes to demonstrate a mechanism for total organ regeneration in which extensive cell movement separates new cell specification from organ morphogenesis. PMID:21852957

  4. Travelers to the FIFA world cup 2014 in Brazil: Health risks related to mass gatherings/sports events and implications for the Summer Olympic Games in Rio de Janeiro in 2016.

    PubMed

    Eberhardt, Kirsten Alexandra; Vinnemeier, Christof David; Dehnerdt, Johanna; Rolling, Thierry; Steffen, Robert; Cramer, Jakob Peter

    2016-01-01

    Health threats during mass gatherings, such as the FIFA world cup 2014 differ from traditional health risks. The influence of event type, demographics of attendees and environmental conditions are still not fully understood. An observational, prospective case-control survey conducted at the Frankfurt international airport in Germany on 544 travelers to the FIFA world cup 2014 and 432 regular travelers to Brazil departing after the end of the world cup. Travelers to the FIFA world cup 2014 were predominantly male whereas the gender distribution in the control group was more balanced. The majority in both groups obtained insect bites and sunburns as environmental risk factors. Every third traveler suffered from diarrheal complaints in both groups, whereas the proportion of travelers with flu-like symptoms was higher in the case group. Travelers to the FIFA world cup 2014 indicated alcohol intake and sexual contacts outside of a relationship more frequently than travelers in the control group. The additional health risks of travelers to sporting events as the FIFA world cup 2014 should be addressed in addition to traditional health threats in pre-travel counseling for the Summer Olympic Games 2016 in Brazil. Copyright © 2016. Published by Elsevier Ltd.

  5. In vitro reproduction of incisal/occlusal cupping/cratering.

    PubMed

    Dzakovich, John J; Oslak, Robert R

    2013-06-01

    Occlusal cupping/cratering (depressed dentin surrounded by elevated rims of enamel) has been postulated to be the result of abrasion, bruxism, attrition, acid erosion, stress corrosion, or a combination of these. The primary etiology or the multifactorial sequence of occlusal cupping/cratering remains scientifically unsubstantiated. The purpose of this study was to reproduce occlusal/incisal cupping/cratering in vitro. This study was designed to create cupping/cratering on the occlusal surfaces of extracted human teeth rather than to quantify the amount of lost tooth structure caused by abrasion. One name-brand toothbrush was tested with 2 different dentifrices (of different abrasive potentials [low and high]) and water only (nonabrasive) on extracted human teeth. Six specimens of 4 teeth each (24 teeth) were subjected to horizontal brushing in a 1:1 toothpaste/water slurry and water only. The control group, brushed with water only, demonstrated no visible loss of tooth structure. Each of the specimens brushed with toothpaste, regardless of the degree of abrasivity, demonstrated visible wear of the dentin, resulting in occlusal/incisal cupping/cratering. Pronounced cupping/cratering was caused by horizontal brushing with commercial toothpastes. Brushing in water demonstrated no visual loss of occlusal tooth structure. (J Prosthet Dent 2013;109:384-391). Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Prototype CoolCup cryolipolysis applicator with over 40% reduced treatment time demonstrates equivalent safety and efficacy with greater patient preference.

    PubMed

    Kilmer, Suzanne L

    2017-01-01

    Cryolipolysis is a safe, effective non-surgical procedure to reduce fat. For most cryolipolysis treatments, tissue is pulled between parallel cooling plates with a treatment duration of 60 minutes. A novel contoured cup, medium-sized applicator was developed to increase tissue contact with reduced skin tension and reduced treatment time. This prototype contoured cup was investigated with a standard cryolipolysis applicator to evaluate safety, efficacy, and patient preference. A prototype CoolCup medium-sized vacuum applicator (CoolSculpting System, ZELTIQ Aesthetics) was used to treat n = 19 subjects in the flanks. Randomly assigned, one flank received standard treatment with the CoolCore applicator (-10°C for 60 minutes). The contralateral flank received treatment from the CoolCup (-11°C for 35 minutes). The clinical study primary efficacy endpoint was 70% correct identification of baseline photographs by independent physician review. Incidence of adverse device effects was monitored. Fat layer reduction was measured by ultrasound and subject surveys were administered 12 weeks post-treatment. Equivalent efficacy was demonstrated between the CoolCore standard treatment and the prototype CoolCup. Independent review from three blinded physicians found 81% correct identification of baseline photographs for the standard treatment and 79% for the CoolCup. Ultrasound measurements indicated mean fat layer reduction of 4.38 mm for the standard treatment and 4.40 mm for the CoolCup; no statistically significant difference was found when comparing treatment efficacy of the two applicators (P = 0.96). Patient questionnaires revealed 85% preferred CoolCup because of shorter treatment duration and greater comfort. Procedural assessments revealed 45% lower pain scores for CoolCup. Immediate post-treatment clinical assessments revealed 82% less bruising. Typical side effects, such as numbness and erythema, were similar. There were no adverse events. This clinical study of a prototype medium-sized vacuum applicator with a cooled contoured surface indicates that the CoolCup produces equivalent safety and efficacy to the standard CoolCore cryolipolysis applicator. With a 42% reduction in treatment time, the procedure was found to be more comfortable because of lower vacuum skin tension and shorter treatment duration. Lasers Surg. Med. 49:63-68, 2017. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. © 2016 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  7. Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty: A Randomized Controlled Trial.

    PubMed

    Sariali, Elhadi; Boukhelifa, Nadia; Catonne, Yves; Pascal Moussellard, Hugues

    2016-01-20

    Malpositioning of the acetabular cup during total hip arthroplasty increases the risk of dislocation, edge-loading, squeaking, early wear, and loosening. We hypothesized that the use of three-dimensional (3-D) visualization tools to identify the planned cup position relative to the acetabular edge intraoperatively would increase the accuracy of cup orientation. The purpose of this study was to compare 3-D planning-assisted implantation and freehand insertion of the acetabular cup. This was a prospective randomized controlled study of two groups of twenty-eight patients each. In the first group, cup positioning was guided by 3-D views of the cup within the acetabulum obtained during 3-D preoperative planning. In the control group, the cup was placed freehand. All of the patients were operated on by the same surgeon, through a minimally invasive direct anterior approach with the patient in the supine position. Cup anteversion and abduction angles were measured on 3-D computed tomography (CT) reconstructions. The main evaluation criterion was the percentage of outliers according to the Lewinnek safe zone. Operative time did not differ between the two groups. The cup anteversion was more accurate in the 3-D planning group (mean difference from the planned angle [and standard deviation], -2.7° ± 5.4°) compared with the freehand-placement group (6.6° ± 9.5°). According to the Lewinnek safe zone, overall, the percentage of outliers was lower in the 3-D planning group (21%; six patients) than in the control group (46%; thirteen patients). According to the Callanan safe zone, the percentage of outliers was also lower in the 3-D planning group (25% versus 64%). Although cup abduction was also restored with greater accuracy in the 3-D planning group, on the basis of the Lewinnek safe zone, the percentage of abduction outliers was comparable between groups, with fewer high-abduction values, but more low-abduction values, in the 3-D planning group. Preoperative 3-D planning increased the accuracy of anteversion restoration and reduced the percentage of outliers without increasing the operative time. In this study, the same advantage could not be demonstrated for abduction. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  8. Fate of the unrevised cemented stem following cup only revision: 227 hips at an average of 6 years follow-up.

    PubMed

    McGonagle, L; Siney, P D; Raut, V V

    2015-11-01

    After primary total hip replacement, aseptic loosening of the acetabular cup is more common than loosening of the femoral stem. Removal of a well-fixed stem adds to operative time, blood loss, risk of bone loss and fracture. There is limited evidence that isolated cup revision can be a safe option in revision hip arthroplasty. We question the following regarding the unrevised cemented stem after isolated cup revision: 1) Does the unrevised stem require revision after isolated cup revision? 2) When is the stem subsequently revised? 3) Why is the stem subsequently revised? 4) Do unrevised stems exhibit radiographic loosening? We hypothesise that after isolated cup revision most unrevised stems do not need subsequent revision, and that most do not exhibit evidence of radiographic loosening. A retrospective analysis of all patients who underwent revision of the acetabular component only during revision hip arthroplasty between March 1970 and July 2013 was carried out. We assessed survival of the unrevised stem, reasons for subsequent revision, plus radiographic analysis for stem loosening. Two hundred and twenty-seven hips were included [215 patients with an average age at the time of primary surgery was 47 (13-70) years]. The Charnley stem was used in 161 cases; C-stem 65, Howse 1. Average time between primary surgery and cup revision was 15.9 (1.6-33.4) years. Average follow-up for all stems post-isolated cup revision was 6.1 (0.1-30.7) years. Twenty-eight stems (12.3%) were subsequently revised 5.1 (0.1-12.6) years after the isolated cup revision. Reasons for subsequent revision were: aseptic loosening (10); infection (8); dislocation (6); unreconstructable joint post-loose cup removal (2); fracture (2). Radiographic review was possible on 140 cases. Five femoral stems were revised and 2 others showed evidence of possible radiological loosening but were not revised. To our knowledge this is the largest series showing that isolated cup revision in the place of a well-fixed cemented stem is safe and is associated with ongoing good long-term survival of the stem. Level IV, retrospective case series. Copyright © 2015. Published by Elsevier Masson SAS.

  9. Birth weight and optic nerve head parameters.

    PubMed

    Samarawickrama, Chameen; Huynh, Son C; Liew, Gerald; Burlutsky, George; Mitchell, Paul

    2009-06-01

    To assess the relationship of birth weight, birth length, and head circumference as proxy markers of intrauterine growth, cup/disc ratio, and other optic disc parameters measured using optical coherence tomography (OCT). Population-based cross sectional analysis. The Sydney Childhood Eye Study examined 2353 primarily 12-year-old children from 21 randomly selected secondary schools during 2003 to 2005. Of 2353 children examined, 2134 (90.7%) had OCT scans (Zeiss Stratus OCT, Carl Zeiss Meditec, Dublin, CA) and are included in this study. The "fast" optic disc scan protocol was used. Birth weight, birth length, and head circumference were ascertained from health records. Height and weight were measured using standardized protocols, body mass index (BMI) was defined as weight (kilograms)/ height squared (meters), and sociodemographic information was collected in a questionnaire completed by parents. Low birth weight was defined as birth weight

  10. Effects of Advice to Drink 8 Cups of Water per Day in Adolescents With Overweight or Obesity: A Randomized Clinical Trial.

    PubMed

    Wong, Julia M W; Ebbeling, Cara B; Robinson, Lisa; Feldman, Henry A; Ludwig, David S

    2017-05-01

    Health care professionals commonly recommend increased water consumption, typically to 8 cups per day, as part of a weight-reducing diet. However, this recommendation is based on limited evidence and virtually no experimental data from the pediatric population. To compare 2 standardized weight-loss diets among adolescents with overweight or obesity, either with or without additional advice and behavioral support to increase habitual water intake to 8 cups per day. A randomized clinical, parallel-group trial was conducted between February 2, 2011, and June 26, 2014, at Boston Children's Hospital, Boston, Massachusetts, among 38 adolescents with overweight or obesity who reported drinking 4 cups or less of water per day. All participants in both groups received similar weight-reducing interventions, differentiated by advice about water intake (the water group received advice to increase water intake to 8 cups per day; the control group did not receive such advice) but controlled for other dietary recommendations and treatment intensity. The interventions included dietary counseling, daily text messages, and a cookbook with health guides. To support adherence to 8 cups of water per day, the water group received well-defined messages about water through counseling and daily text messages, a water bottle, and a water pitcher with filters. The primary outcome was 6-month change in body mass index z score. Data analyses followed the intention-to-treat principle. All 38 participants (27 girls and 11 boys; mean [SD] age, 14.9 [1.7] years) completed the study. Both groups reported drinking approximately 2 cups of water per day at baseline. Self-reported change in water intake at 6 months was greater in the water group (difference from baseline, 2.8 cups per day [95% CI, 1.8 to 3.8]; P < .001) compared with that in the control group (difference from baseline, 1.2 cups per day [95% CI, 0.2 to 2.2]; P = .02) (difference between groups, 1.6 cups per day [95% CI, 0.2 to 3.0 cups per day]; P = .03). The 6-month change in body mass index z score did not differ between the water group (difference from baseline, -0.1 [95% CI, -0.2 to -0.0]; P = .005) and the control group (difference from baseline, -0.1 [95% CI, -0.2 to -0.0]; P = .008) (difference between groups, -0.0 [95% CI, -0.1 to 0.1]; P = .88). Advice and behavioral supports to consume 8 cups of water per day in the context of a weight-reducing diet did not affect body weight among adolescents with overweight or obesity. Despite intensive behavior supports, few adolescents achieved the target of 8 cups of water per day. Environmental interventions to reduce barriers to water consumption at school may be necessary in future research of the feasibility and effectiveness to achieve the target of an intake of 8 cups of water per day in adolescents. clinicaltrials.gov Identifier: NCT01044134.

  11. Teaching Flowers: A Photo Essay

    ERIC Educational Resources Information Center

    Hewson, Federico

    2017-01-01

    "Teaching Flowers" reflects on humanity's deep connections to horticulture by gathering varied thoughts from seminal writers in the field. In addition, this visual article draws attention to labor issues within the U.S. floral industry by documenting the author's exploration of flowers as social sculpture in New York City.

  12. Phonetics and Other Disciplines: Then and Now.

    ERIC Educational Resources Information Center

    Bronstein, Arthur J.; Raphael, Lawrence J.

    Phonetic science is becoming increasingly interdisciplinary. Phoneticians rely on, or at least collaborate with, sociologists, psychologists, biologists, poets, physicists, anthropologists, neurologists and others. A look at the history of phonetics reveals that this seemingly recent trend has deep roots. In fact, it is possible to draw parallels…

  13. Thinking big

    NASA Astrophysics Data System (ADS)

    Collins, Harry

    2008-02-01

    Physicists are often quick to discount social research based on qualitative techniques such as ethnography and "deep case studies" - where a researcher draws conclusions about a community based on immersion in the field - thinking that only quantitative research backed up by statistical analysis is sound. The balance is not so clear, however.

  14. Finding Meaning: Sense Inventories for Improved Word Sense Disambiguation

    ERIC Educational Resources Information Center

    Brown, Susan Windisch

    2010-01-01

    The deep semantic understanding necessary for complex natural language processing tasks, such as automatic question-answering or text summarization, would benefit from highly accurate word sense disambiguation (WSD). This dissertation investigates what makes an appropriate and effective sense inventory for WSD. Drawing on theories and…

  15. The Impact of Data Fragmentation on High-Throughput Clinical Phenotyping

    ERIC Educational Resources Information Center

    Wei, Weiqi

    2012-01-01

    Subject selection is essential and has become the rate-limiting step for harvesting knowledge to advance healthcare through clinical research. Present manual approaches inhibit researchers from conducting deep and broad studies and drawing confident conclusions. High-throughput clinical phenotyping (HTCP), a recently proposed approach, leverages…

  16. Wilderness Vision Quest: A Journey of Transformation.

    ERIC Educational Resources Information Center

    Brown, Michael H.

    The Wilderness Vision Quest is an outdoor retreat which helps participants touch, explore, and develop important latent human resources such as imagination, intuition, creativity, inspiration, and insight. Through the careful and focused use of techniques such as deep relaxation, reflective writing, visualization, guided imagery, symbolic drawing,…

  17. Catholic Education: From and for Faith

    ERIC Educational Resources Information Center

    Groome, Thomas

    2014-01-01

    Catholic education arises from the deep structures and earliest traditions of Christian faith. Its commitments throughout the centuries have been to educate both "from" and "for" faith. It educates from a faith perspective by drawing upon the universal values of Catholicism to provide a distinctive philosophy, perhaps even more…

  18. Investigation of trophic ecology in Newfoundland cold-water deep-sea corals using lipid class and fatty acid analyses

    NASA Astrophysics Data System (ADS)

    Salvo, Flora; Hamoutene, Dounia; Hayes, Vonda E. Wareham; Edinger, Evan N.; Parrish, Christopher C.

    2018-03-01

    The trophic behavior of some deep-sea Newfoundland cold-water corals was explored using fatty acid (FA) and lipid profiles. No significant effect of geographic location and/or depth was identified in lipid or FA composition. However, differences were detected between and within taxon groups in hexa- or octocoral subclasses. Phospholipids constituted the main lipid class in all groups except black-thorny corals which had less structural lipids likely due to their morphology (stiff axes) and slower growth rates. Within each subclass, major differences in the identity of dominant FAs were detected at the order level, whereas differences between species and taxon groups of the same order were mainly driven by a variation in proportions of the dominant FA. Soft corals and gorgonians (Order Alcyonacea) were close in composition and are likely relying on phytodetritus resulting from algae, macrophytes and/or foraminifera, while sea pens (Order Pennatulacea) seem to consume more diatoms and/or herbivorous zooplankton with the exception of Pennatula sp. In the hexacoral subclass, black-thorny corals ( Stauropathes arctica) differed significantly from the stony-cup corals ( Flabellum alabastrum); S. arctica was seemingly more carnivorous (zooplankton markers) than F. alabastrum, which appears omnivorous (phyto- and zooplankton markers). Our results suggest that deep-sea corals are not as opportunistic as expected but have some selective feeding associated with taxonomy.

  19. The effect of bearing friction torques on the primary stability of press-fit acetabular cups: A novel in vitro method.

    PubMed

    Alexander, Jahnke; Stefan, Schroeder; Alfonso, Fonseca Ulloa Carlos; Adam, Ahmed Gafar; Alexander, Ishaque Bernd; Markus, Rickert

    2018-05-10

    Aseptic loosening is the main reason for revision of total hip arthroplasty, and relative micromotions between cementless acetabular cups and bone play an important role regarding their comparatively high loosening rate. Therefore, the aim of the present study was to analyze the influence of resulting frictional torques on the primary stability of press-fit acetabular cups subjected to two different bearing partners. A cementless press-fit cup was implanted in bone-like foam. Primary stability of the cup was analyzed by determining spatial total, translational and rotational interface micromotions by means of an eddy current sensor measuring system. Torque transmission into the cup was realized by three synchronous servomotors considering resultant friction torques based on constant friction for ceramic-on-ceramic (CoC: µ = 0.044; max. resultant torque: 1.5 Nm) and for ceramic-on-polyethylene (CoP: µ = 0.063; max. resultant torque: 1.9 Nm) bearing partners. Rotational micromotion of CoC was 8.99 ± 0.85µm and of CoP 13.39 ± 1.43µm. Translational micromotion of CoC was 29.93 ± 1.44µm and of CoP 39.91 ± 2.25µm. Maximum total relative micromotions were 37.10 ± 1.07µm for CoC and 51.64 ± 2.18µm for CoP. Micromotions resulting from CoC were statistically lower than those resulting from CoP (p < 0.05). The described 3D-measuring set-up offers a novel in vitro method of measuring primary stability of acetabular cups. We can therefore conclude, that primary stability of acetabular cup systems can be observed using either the lower friction curve (CoC) or the higher friction curve (CoP). In future studies different cup designs or cup fixation mechanisms may be tested and compared in vitro and assessed prior to implantation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. [Combination of acupuncture, cupping and medicine for treatment of fibromyalgia syndrome: a multi-central randomized controlled trial].

    PubMed

    Jang, Zhen-Ya; Li, Chang-Du; Qiu, Ling; Guo, Jun-Hua; He, Ling-Na; Yue, Yang; Li, Fang-Ze; Qin, Wen-Yi

    2010-04-01

    To evaluate the clinical effect of combination of acupuncture, cupping and medicine for treatment of fibromyalgia syndrome. By using multi-central randomized controlled method, 186 cases were randomly divided into an acupuncture combined with cupping and western medicine group (group A), an acupuncture combined with cupping group (group B) and a western medicine group (group C) and treated continuously for 4 weeks. The treatment of acupuncture combined with cupping was produced by acupuncture at five mental points and moving cupping on the Hechelu of the back, once evrey other day, thrice each week, and the western medicine therapy by oral administration of Amitriptyline, once each day. The scores of McGill Pain Questionnaire (MPQ), the amount of tenderness point and the time of producing effect were compared and the therapeutic effects were assessed with the Hamilton Depression Scale (HAMD). The cured and markedly effective rate was 65.0% (39/60) in the group A, which was superior to 15.9% (10/63) in the group B and 16.1% (9/56) in the group C (both P < 0.001). After treatment, the scores of MPQ and HAMD and the amount of tenderness point all decreased in the three groups, group A being significantly better than group B and group C, and the time of producing effect in the group A was more earlier than those in the group B and the group C. The therapeutic effect of combination of acupuncture, cupping and medicine on fibromyalgia syndrome is superior to that of the simple acupuncture combined with cupping or the simple medicine.

  1. [Observation on therapeutic effect of chronic fatigue syndrome treated with coiling dragon needling and moving cupping on back].

    PubMed

    Xu, Wei; Zhou, Ri-Hua; Li, Lei; Jiang, Ming-Wei

    2012-03-01

    To compare the differences of therapeutic effect of chronic fatigue syndrome treated with the combined therapy of coiling dragon needling and cupping on back and the western medicine therapy with Prednisone. Seventy-two cases were randomly divided into an acupuncture and cupping group (37 cases) and a Prednisone group (35 cases). In acupuncture and cupping group, Jiaji (EX-B 2) points of T1--L5 were applied with coiling dragon needling (once a day), combined with moving cupping on back (once every two days); in Prednisone group, Prednisone tablets were orally taken for 10 mg at 8:00 am. Seven days made one course, and 2 courses were carried on totally. FS-14 scale and BELL's chronic fatigue syndrome integral table were applied to evaluate the fatigue degree of patients before and after treatment, and the therapeutic effects of both groups were compared. After one course of treatment, the BELL's scores of both groups were obviously improved (both P < 0.01), but there was no significant difference between groups (P > 0.05); after two courses of treatment, the BELL's score in acupuncture and cupping group improved more obviously than that in Prednisone group, and the total effective rate of 91.9% (34/37) in acupuncture and cupping group was superior to that of 71.4% (25/35) in Prednisone group (P < 0.05). The therapeutic effect of chronic fatigue syndrome treated with coiling dragon needling and moving cupping on back is positive, superior to that of Prednisone with oral administration.

  2. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    PubMed

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    PubMed

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of <50). The proportion of patients with the cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  4. Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions.

    PubMed

    Yun, Hohyun; Murphy, William S; Ward, Daniel M; Zheng, Guoyan; Hayden, Brett L; Murphy, Stephen B

    2018-05-01

    The purpose of this study is to analyze the effect of pelvic tilt and rotation on radiographic measurement of cup orientation. A total of 68 patients (79 hips) were included in this study. The patients had a computed tomography study and approximately 3 months of postoperative standing anteroposterior pelvic radiographs in both supine and standing positions. We used 2-dimensional (2D)/3-dimensional (3D) matching to measure pelvic tilt and rotation, and cup orientation. There was a wide range of pelvic tilt between individuals in both supine and standing positions. Supine pelvic tilt was different from standing pelvic tilt (P < .05). There were differences in cup anteversion before and after 2D/3D matching in both supine and standing positions (P < .05). Supine and standing pelvic tilt correlated with differences in cup anteversion before and after 2D/3D matching. When all 79 hips were separated into right and left side, pelvic rotation inversely correlated with the pelvic tilt-adjusted difference in anteversion before and after 2D/3D matching of the right side but directly correlated with that of the left side in both supine and standing positions. This study demonstrated that the measurement of cup anteversion on anteroposterior radiographs is significantly affected by both pelvic tilt and pelvic rotation (depending on the side). Improved understanding of pelvic orientation and improved ability to measure pelvic orientation may eventually allow for desired cup positioning to potentially protect against complications associated with malposition of the cup. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Influence of Surgical Approach on Pelvic Lift in Hip Arthroplasty During Cup Insertion.

    PubMed

    Brodt, Steffen; Windisch, Christoph; Krakow, Linda; Nowack, Dimitri; Matziolis, Georg

    2017-07-01

    The position of the acetabular cup is a major factor in the long-term outcome of total hip arthroplasty (THA). Malpositioning of the acetabular cup frequently has been reported with the use of a minimally invasive implantation technique. It remains unclear whether the limited visibility or the increased retractor traction and thus tilting of the pelvis during cup implantation is the cause. This study investigated the influence of iatrogenically related pelvic lift using an anterolateral minimally invasive THA technique. In a group of 30 consecutive patients who underwent THA via a minimally invasive anterolateral approach, iatrogenic lifting of the pelvis was measured with a smartphone using a 3-axis accelerometer and compared with patients in a historical age- and sex-matched control group who underwent THA using a transgluteal approach. Postoperatively, the inclination and anteversion of the cup was determined on pelvic radiographs. In the anterolateral group, the pelvis was lifted by a maximum of 6.3° and by an average of 3.9° when the acetabular cup was impacted; no difference was noted compared with the transgluteal group. In contrast, the cups in the anterolateral group showed significantly increased inclination and reduced anteversion. In both techniques, the iatrogenic tilting of the pelvis at the time of cup implantation occurred to a comparable extent. Therefore, the significant differences in postoperative radiographs cannot be attributed to increased retractor traction on exposure of the acetabulum, which means that the limited visibility must be responsible. [Orthopedics. 2017; 40(4):e589-e593.]. Copyright 2017, SLACK Incorporated.

  6. Application of shell elements in simulation of cans ironing

    NASA Astrophysics Data System (ADS)

    Andrianov, A. V.; Erisov, Y. A.; Aryshensky, E. V.; Aryshensky, V. Y.

    2017-01-01

    In the present study, the special shell finite elements are used to simulate the drawing with high ironing ratio of aluminum beverage cans. These elements are implemented in commercial software complex PAM-STAMP 2G by means of T.T.S. normal stress option, which is used for ironing to describe well normal stress. By comparison of simulation and experimental data, it is shown that shell elements with T.T.S. option are capable to provide accurate simulation of deep drawing and ironing. The error of can thickness and height computation agrees with the engineering computation accuracy.

  7. STS mission duration enhancement study: (orbiter habitability)

    NASA Technical Reports Server (NTRS)

    Carlson, A. D.

    1979-01-01

    Habitability improvements for early flights that could be implemented with minimum impact were investigated. These included: (1) launching the water dispenser in the on-orbit position instead of in a locker; (2) the sleep pallet concept; and (3) suction cup foot restraints. Past studies that used volumetric terms and requirements for crew size versus mission duration were reviewed and common definitions of key habitability terms were established. An accurately dimensioned drawing of the orbiter mid-deck, locating all of the known major elements was developed. Finally, it was established that orbiter duration and crew size can be increased with minimum modification and impact to the crew module. Preliminary concepts of the aft med-deck, external versions of expanded tunnel adapters (ETA), and interior concepts of ETA-3 were developed and comparison charts showing the various factors of volume, weight, duration, size, impact to orbiter, and number of sleep stations were generated.

  8. a Walk Through Earth's Time

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Turrin, M.

    2012-12-01

    After "What is this rock?" the most common questions that is asked of Geologists is "How old is this rock/fossil?" For geologists considering ages back to millions of years is routine. Sorting and cataloguing events into temporal sequences is a natural tendency for all humans. In fact, it is an everyday activity for humans, i.e., keeping track of birthdays, anniversaries, appointments, meetings, AGU abstract deadlines etc… However, the time frames that are most familiar to the non scientist (seconds, minutes, hours, days, years) generally extend to only a few decades or at most centuries. Yet the vast length of time covered by Earth's history, 4.56 billion years, greatly exceeds these timeframes and thus is commonly referred to as "Deep Time". This is a challenging concept for most students to comprehend as it involves temporal and abstract thinking, yet it is key to their successful understanding of numerous geologic principles. We have developed an outdoor learning activity for general Introductory Earth Science courses that incorporates several scientific and geologic concepts such as: linear distance or stratigraphic thickness representing time, learning about major events in Earth's history and locating them in a scaled temporal framework, field mapping, abstract thinking, scaling and dimensional analysis, and the principles of radio isotopic dating. The only supplies needed are readily available in local hardware stores i.e. a 300 ft. surveyor's tape marked in feet, and tenths and hundredths of a foot, and the student's own introductory geology textbook. The exercise employs a variety of pedagogical learning modalities, including traditional lecture-based, the use of Art/Drawing, use of Visualization, Collaborative learning, and Kinesthetic and Experiential learning. Initially the students are exposed to the concept of "Deep Time" in a short conventional introductory lecture; this is followed by a 'field day'. Prior to the field exercise, students work with their textbook selecting events is Earth History that they find interesting. Using the textbook and online resources they then draw figures that represent these events. The drawing exercise reinforces the learning by having students visualize (imprinting an image) of these geologic events. Once the students have produced their drawings, the outdoor field exercise follows. Working collaboratively, the students measure and lay out a scaled linear model representing 4.56 billion years of geologic time. They then organize and place their drawings in the proper sequence on the temporal model that they have created. Once all the drawings are in place they are able to visualize the expanse of time in Earth's history. Through comparing results from a pre-test to those from a post-test we can show the gains in student understanding of Deep Time, a concept that is central to many of our geologic understandings.

  9. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver Cup...

  10. 76 FR 66613 - Airworthiness Directives; Eurocopter France (Eurocopter) Model EC225LP Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-27

    ... were missing. Further investigation has shown that some of the cup washers that need to be used in... cup washers that need to be used in installing the countersunk head screws, which attach the pilot's... is missing, the ASB specifies removing the affected seat, checking for cup washers, and performing...

  11. Athletic Departments' Operating Expenses as a Predictor of Their Directors' Cup Standing

    ERIC Educational Resources Information Center

    Magner, Amber

    2014-01-01

    The NACDA Directors' Cup is a competition utilizing an unbiased scoring system that encourages a broad based athletic department as the standard for defining intercollegiate athletic success. Therefore, for NCAA DI athletic administrators the Directors' Cup should be the standard for defining intercollegiate athletic success. The purpose of this…

  12. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver Cup...

  13. 75 FR 18231 - Central Utah Project Completion Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-09

    ... a proposed conversion of up to 12,100 acre feet of Central Utah Project (CUP) Bonneville Unit water... that has been made available under Block Notice 1A of the CUP. The delivery area could be expanded to include additional land in Wasatch County. The Bonneville Unit of the CUP was authorized to develop a...

  14. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  15. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  16. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  17. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  18. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  19. 7 CFR 225.16 - Meal service requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... cup. Cooked pasta or noodle products or an equivalent quantity of any combination of bread/bread... measuring cup. 2 Bread, pasta or noodle products, and cereal grains (such as rice, bulgur, or corn grits..., muffins, etc. or 1 serving. 7 Cooked pasta or noodle products or 1/2 cup. Cooked cereal grains or an...

  20. Acquisition of cup drinking using previously refused foods as positive and negative reinforcement.

    PubMed

    Kelley, Michael E; Piazza, Cathleen C; Fisher, Wayne W; Oberdorff, Amanda J

    2003-01-01

    We used previously refused foods as positive and negative reinforcement in the acquisition of cup drinking. Cup drinking increased with positive and negative reinforcement, both alone and in combination (without escape extinction), indicating that treatment of food refusal can establish some foods as appetitive stimuli whereas others remain aversive.

  1. Numerosity Discrimination in Preschool Children

    ERIC Educational Resources Information Center

    Almeida, Alzira; Arantes, Joana; Machado, Armando

    2007-01-01

    We used a numerical bisection procedure to examine preschool children's sensitivity to the numerical attributes of stimuli. In Experiment 1 children performed two tasks. In the Cups Task they earned coins for choosing a green cup after two drumbeats and a blue cup after eight drumbeats. In the Gloves Task they earned coins for raising a red glove…

  2. Impact of the National School Lunch Program on Fruit and Vegetable Selection in Northeastern Elementary Schoolchildren, 2012-2013.

    PubMed

    Amin, Sarah A; Yon, Bethany A; Taylor, Jennifer C; Johnson, Rachel K

    2015-01-01

    Increasing children's fruit and vegetable (FV) consumption is an important goal of the U.S. Department of Agriculture's (USDA's) National School Lunch Program. Since 2012, the USDA's requirement that children select FVs at lunch as part of the reimbursable school meal has been met with concern and evidence of food waste. We compared elementary schoolchildren's FV selection, consumption, and waste before (10 school visits, 498 tray observations) and after (11 school visits, 944 tray observations) implementation of this requirement using validated dietary assessment measures. More children selected FVs in higher amounts when FVs were required compared with when they were optional (0.69 cups vs. 0.89 cups, p<0.001); however, consumption decreased slightly (0.51 cups vs. 0.45 cups, p=0.01) and waste increased (0.25 cups vs. 0.39 cups, p<0.001) when FVs were required compared with when they were optional. More exposure to FVs in schools through programmatic efforts and in the home environment may help familiarize children with FV offerings and encourage consumption.

  3. Dielectric elastomer actuators for octopus inspired suction cups.

    PubMed

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  4. Octopus-like suction cups: from natural to artificial solutions.

    PubMed

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  5. Characterization and correction of cupping effect artefacts in cone beam CT

    PubMed Central

    Hunter, AK; McDavid, WD

    2012-01-01

    Objective The purpose of this study was to demonstrate and correct the cupping effect artefact that occurs owing to the presence of beam hardening and scatter radiation during image acquisition in cone beam CT (CBCT). Methods A uniform aluminium cylinder (6061) was used to demonstrate the cupping effect artefact on the Planmeca Promax 3D CBCT unit (Planmeca OY, Helsinki, Finland). The cupping effect was studied using a line profile plot of the grey level values using ImageJ software (National Institutes of Health, Bethesda, MD). A hardware-based correction method using copper pre-filtration was used to address this artefact caused by beam hardening and a software-based subtraction algorithm was used to address scatter contamination. Results The hardware-based correction used to address the effects of beam hardening suppressed the cupping effect artefact but did not eliminate it. The software-based correction used to address the effects of scatter resulted in elimination of the cupping effect artefact. Conclusion Compensating for the presence of beam hardening and scatter radiation improves grey level uniformity in CBCT. PMID:22378754

  6. Ilaj bil hijamah (cupping therapy) in the Unani system of medicine: anecdotal practice to evidence based therapy.

    PubMed

    Abbas Zaidi, S M; Jameel, S S; Jafri, Kehkashan; Khan, Shariq A; Ahmad, Ehsan

    2016-08-01

    Cupping (Hijamah) therapy is very well documented as a result of several thousand years of clinical experiences in Unani medicine. In this procedure, suction is created by various means either with or without bloodletting. Though this therapy is being widely practiced across the globe for treating many chronic and intractable ailments but many reports reveal its unscientific and improper practices which results in many complications. Therefore to develop standard operative procedures and to propose protocols of cupping therapy in various diseases is the need of hour. A thorough literature review of relevant journals and textbooks was performed to gather the maximum available data on cupping therapy. This paper seeks to introduce the general concepts of cupping therapy in Unani medicine and other traditional systems of medicine, shortcomings and limitations of the currently published studies and suggest ways to improve these technical/methodological flaws. In addition, the authors have also attempted to provide the cupping related materials, hypotheses, observations which will provide the researchers the base for evaluating their usefulness in future clinical trials.

  7. Safety of cupping during bevacizumab therapy.

    PubMed

    Klempner, Samuel J; Costa, Daniel B; Wu, Peggy A; Ariyabuddhiphongs, Kim D

    2013-08-01

    This study reports on the safety of the complementary and alternative medicine (CAM) practice of cupping in a patient undergoing concomitant therapy with bevacizumab for advanced non-small-cell lung cancer (NSCLC), and raises awareness of the need for improved communication between CAM practitioners and oncologists during the care of patients with cancer. The practice of cupping generates local hyperemia, disrupts superficial vasculature in the dermis, and leads to cutaneous lesions including circular erythema, edema, and subsequently ecchymosis. There are no data on the safety of cupping in patients being treated with bevacizumab. This is a single-institution case report. The setting for this study was a tertiary-care academic medical center. A patient with advanced NSCLC received four cycles of carboplatin AUC 6, paclitaxel 200 mg/m(2), and bevacizumab 15 mg/kg, and was continued on every-3-week maintenance bevacizumab 15 mg/kg. The patient underwent glass dry cupping during cycle six of maintenance bevacizumab treatment without overt cutaneous adverse events or bleeding. The patient did not realize he should have communicated his cupping plans or recent bevacizumab treatment with his providers.

  8. Testing methods of pressure distribution of bra cups on breasts soft tissue

    NASA Astrophysics Data System (ADS)

    Musilova, B.; Nemcokova, R.; Svoboda, M.

    2017-10-01

    Objective of this study is to evaluate testing methods of pressure distribution of bra cups on breasts soft tissue, the system which do not affect the space between the wearer's body surface and bra cups and thus do not influence the geometry of the measured body surface and thus investigate the functional performance of brassieres. Two measuring systems were used for the pressure comfort evaluating: 1) The pressure distribution of a wearing bra during 20 minutes on women's breasts has been directly measured using pressure sensor, a dielectricum which is elastic polyurethane foam bra cups. Twelve points were measured in bra cups. 2) Simultaneously the change of temperature in the same points bra was tested with the help of noncontact system the thermal imager. The results indicate that both of those systems can identify different pressure distribution at different points. The same size of bra designing features bra cups made from the same material and which is define by the help of same standardised body dimensions (bust and underbust) can cause different value of a compression on different shape of a woman´s breast soft tissue.

  9. Region-based multi-step optic disk and cup segmentation from color fundus image

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Lock, Jane; Manresa, Javier Moreno; Vignarajan, Janardhan; Tay-Kearney, Mei-Ling; Kanagasingam, Yogesan

    2013-02-01

    Retinal optic cup-disk-ratio (CDR) is a one of important indicators of glaucomatous neuropathy. In this paper, we propose a novel multi-step 4-quadrant thresholding method for optic disk segmentation and a multi-step temporal-nasal segmenting method for optic cup segmentation based on blood vessel inpainted HSL lightness images and green images. The performance of the proposed methods was evaluated on a group of color fundus images and compared with the manual outlining results from two experts. Dice scores of detected disk and cup regions between the auto and manual results were computed and compared. Vertical CDRs were also compared among the three results. The preliminary experiment has demonstrated the robustness of the method for automatic optic disk and cup segmentation and its potential value for clinical application.

  10. Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component.

    PubMed

    John, Thomas K; Ghosh, Gaurav; Ranawat, Chitranjan S; Ranawat, Amar S; Meftah, Morteza

    2015-12-01

    The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan-Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Match statistics related to winning in the group stage of 2014 Brazil FIFA World Cup.

    PubMed

    Liu, Hongyou; Gomez, Miguel-Ángel; Lago-Peñas, Carlos; Sampaio, Jaime

    2015-01-01

    Identifying match statistics that strongly contribute to winning in football matches is a very important step towards a more predictive and prescriptive performance analysis. The current study aimed to determine relationships between 24 match statistics and the match outcome (win, loss and draw) in all games and close games of the group stage of FIFA World Cup (2014, Brazil) by employing the generalised linear model. The cumulative logistic regression was run in the model taking the value of each match statistic as independent variable to predict the logarithm of the odds of winning. Relationships were assessed as effects of a two-standard-deviation increase in the value of each variable on the change in the probability of a team winning a match. Non-clinical magnitude-based inferences were employed and were evaluated by using the smallest worthwhile change. Results showed that for all the games, nine match statistics had clearly positive effects on the probability of winning (Shot, Shot on Target, Shot from Counter Attack, Shot from Inside Area, Ball Possession, Short Pass, Average Pass Streak, Aerial Advantage and Tackle), four had clearly negative effects (Shot Blocked, Cross, Dribble and Red Card), other 12 statistics had either trivial or unclear effects. While for the close games, the effects of Aerial Advantage and Yellow Card turned to trivial and clearly negative, respectively. Information from the tactical modelling can provide a more thorough and objective match understanding to coaches and performance analysts for evaluating post-match performances and for scouting upcoming oppositions.

  12. FLOW (finding lasting options for women)

    PubMed Central

    Howard, Courtney; Rose, Caren Lee; Trouton, Konia; Stamm, Holly; Marentette, Danielle; Kirkpatrick, Nicole; Karalic, Sanja; Fernandez, Renee; Paget, Julie

    2011-01-01

    Abstract Objective To determine whether menstrual cups are a viable alternative to tampons. Design Randomized controlled trial. Setting Prince George, Victoria, and Vancouver, BC. Participants A total of 110 women aged 19 to 40 years who had previously used tampons as their main method of menstrual management. Intervention Participants were randomized into 2 groups, a tampon group and a menstrual cup group. Using online diaries, participants tracked 1 menstrual cycle using their regular method and 3 menstrual cycles using the method of their allocated group. Main outcome measures Overall satisfaction; secondary outcomes included discomfort, urovaginal infection, cost, and waste. Results Forty-seven women in each group completed the final survey, 5 of whom were subsequently excluded from analysis (3 from the tampon group and 2 from the menstrual cup group). Overall satisfaction on a 7-point Likert scale was higher for the menstrual cup group than for the tampon group (mean [standard deviation] score 5.4 [1.5] vs 5.0 [1.0], respectively; P = .04). Approximately 91% of women in the menstrual cup group said they would continue to use the cup and recommend it to others. Women used a median of 13 menstrual products per cycle, or 169 products per year, which corresponds to approximately 771 248 400 products used annually in Canada. Estimated cost for tampon use was $37.44 a year (similar to the retail cost of 1 menstrual cup). Subjective vaginal discomfort was initially higher in the menstrual cup group, but the discomfort decreased with continued use. There was no significant difference in physician-diagnosed urovaginal symptoms between the 2 groups. Conclusion Both of the menstrual management methods evaluated were well tolerated by subjects. Menstrual cups are a satisfactory alternative to tampons and have the potential to be a sustainable solution to menstrual management, with moderate cost savings and much-reduced environmental effects compared with tampons. Trial registration number C06-0478 (ClinicalTrials.gov). PMID:21673197

  13. The effectiveness of wet-cupping for nonspecific low back pain in Iran: a randomized controlled trial.

    PubMed

    Farhadi, Khosro; Schwebel, David C; Saeb, Morteza; Choubsaz, Mansour; Mohammadi, Reza; Ahmadi, Alireza

    2009-01-01

    To determine the efficacy of wet-cupping for treating persistent nonspecific low back pain. Wet-cupping therapy is one of the oldest known medical techniques. It is still used in several contemporary societies. Very minimal empirical study has been conducted on its efficacy. Randomized controlled trial with two parallel groups. Patients in the experimental group were offered the option of referral to the wet-cupping service; all accepted that option. The control group received usual care. Medical clinic in Kermanshah, Iran. In total, 98 patients aged 17-68 years with nonspecific low back pain; 48 were randomly assigned to experimental group and 50 to the control group. Patients in the experimental group were prescribed a series of three staged wet-cupping treatments, placed at 3 days intervals (i.e., 0, 3, and 6 days). Patients in the control group received usual care from their general practitioner. Three outcomes assessed at baseline and again 3 months following intervention: the McGill Present Pain Index, Oswestry Pain Disability Index, and the Medication Quantification Scale. Wet-cupping care was associated with clinically significant improvement at 3-month follow-up. The experimental group who received wet-cupping care had significantly lower levels of pain intensity ([95% confidence interval (CI) 1.72-2.60] mean difference=2.17, p<0.01), pain-related disability (95% CI=11.18-18.82, means difference=14.99, p<0.01), and medication use (95% CI=3.60-9.50, mean difference=6.55, p<0.01) than the control group. The differences in all three measures were maintained after controlling for age, gender, and duration of lower back pain in regression models (p<0.01). Traditional wet-cupping care delivered in a primary care setting was safe and acceptable to patients with nonspecific low back pain. Wet-cupping care was significantly more effective in reducing bodily pain than usual care at 3-month follow-up.

  14. [Clinical observation of post-herpetic neuralgia treated with TCM herbal cupping therapy].

    PubMed

    Wu, Xi; Hu, Hui; Guo, Liang; Wang, Hui

    2013-02-01

    To compare the difference in the efficacy on post-herpetic neuralgia among TCM herbal cupping therapy, Chinese medicine thermal compressing therapy and mecobalamine. Fifty-seven cases were randomized into a TCM herbal cupping group, a thermal compressing group and a western medicine group, 19 cases in each one. The oral administration of ibuprofen was applied in every group. In the herbal cupping group, the bamboo cups soaked in the boiled Chinese herbal decoction were sucked on the most significant painful area. In the thermal compressing group, the towel soaked in the boiled Chinese herbal decoction was compressed on the most significant painful area. In the medication group, the muscular injection of mecobalamine was adopted. The treatment was given once a day, for 2 weeks totally in each group. SF-MPQ score and clinical efficacy before and after treatment were observed in each group. The remarkable effective rates were 78.9% (15/19), 36.8% (7/19) and 5.3% (1/19) in the TCM herbal cupping group, thermal compressing group and western medicine group separately. The efficacy in the TCM herbal cupping group was significantly superior to the thermal compressing group and western medicine group (all P < 0.05), and that in the thermal compressing group was superior to the western medicine group (P < 0.05). After treatment, SF-MPQ score was reduced significantly in each group (P < 0.001, P < 0.01). The score in the herbal cupping group was reduced more significantly as compared with the thermal compressing group and western medicine group (all P < 0.01). The improvement in pain in the thermal compressing group was superior to the western medicine group (P < 0.01). TCM herbal cupping therapy achieves the superior efficacy for post-herpetic neuralgia and relieves pain effectively of the patients, which is more advantageous than CM herbal thermal compressing therapy and Mecobalamine.

  15. [Clinical observation on the therapeutic effect of electroacupuncture combined with cupping on post-stroke fatigue].

    PubMed

    Zhou, Yuan; Zhou, Guo-Ying; Li, Shao-Kun; Jin, Jian-Hong

    2010-10-01

    To observe the therapeutic effect of electroacupuncture (EA) combined with cupping at the lumbo-back on post-stroke fatigue. A total of 128 cases of post-stroke fatigue patients were randomly divided into EA + cupping group and medication group, with 64 cases in each group. EA (20 Hz, 2 mA) was applied to Baihui (GV 20), Yintang (EX-HN 3), Shuigou (GV 26), Hegu (LI 4), Zusanli (ST 36), Sanyinjiao (SP 6), and Taichong (LR 3) for 30 min, once daily for 30 times, and cupping was applied at the patient's lumbo-back region once every two days, and continuously for 5 weeks. Patients of medication group were ordered to take compound aminobutyric acid vitamin E capsule (20 mg, t. i.d, po), magnesium gluconate solution (10 mL, t. i. d, po), sertraline hydrochloridetablet (50 mg, qd, po) for 5 weeks. The Stroke Specific Quality of Life Scale (SS-QOL) was used to evaluate the patients' energy state. After the treatment, the energy scores of SS-QOL of both EA + cupping and medication groups were increased significantly in comparison with the pre-treatment in each group (P < 0.05), and that of the EA+ cupping group was significantly higher than the score of the medication group (P < 0.05). Of the two 64 cases in EA + cupping group and medication group, 42 and 23 were recovered basically, 13 and 13 experienced marked improvement, 7 and 18 were effective, 2 and 10 failed in the treatment, with the effective rates being 96.87% and 84.37% respectively. The effective rate of EA + cupping group was obviously higher than that of medication group (P < 0.01). EA+ cupping at the lumbo-back can effectively relieve fatigue of post-stroke patients, and its therapeutic effect is superior to medication.

  16. The challenge of pelvic discontinuity: cup-cage reconstruction does better than conventional cages in mid-term.

    PubMed

    Abolghasemian, M; Tangsaraporn, S; Drexler, M; Barbuto, R; Backstein, D; Safir, O; Kuzyk, P; Gross, A

    2014-02-01

    The use of ilioischial cage reconstruction for pelvic discontinuity has been replaced by the Trabecular Metal (Zimmer, Warsaw, Indiana) cup-cage technique in our institution, due to the unsatisfactory outcome of using a cage alone in this situation. We report the outcome of 26 pelvic discontinuities in 24 patients (20 women and four men, mean age 65 years (44 to 84)) treated by the cup-cage technique at a mean follow-up of 82 months (12 to 113) and compared them with a series of 19 pelvic discontinuities in 19 patients (18 women and one man, mean age 70 years (42 to 86)) treated with a cage at a mean follow-up of 69 months (1 to 170). The clinical and radiological outcomes as well as the survivorship of the groups were compared. In all, four of the cup-cage group (15%) and 13 (68%) of the cage group failed due to septic or aseptic loosening. The seven-year survivorship was 87.2% (95% confidence interval (CI) 71 to 103) for the cup-cage group and 49.9% (95% CI 15 to 84) for the cage-alone group (p = 0.009). There were four major complications in the cup-cage group and nine in the cage group. Radiological union of the discontinuity was found in all successful cases in the cup-cage group and three of the successful cage cases. Three hips in the cup-cage group developed early radiological migration of the components, which stabilised with a successful outcome. Cup-cage reconstruction is a reliable technique for treating pelvic discontinuity in mid-term follow-up and is preferred to ilioischial cage reconstruction. If the continuity of the bone graft at the discontinuity site is not disrupted, early migration of the components does not necessarily result in failure.

  17. Patterns of care and survival after a cancer of unknown primary (CUP) diagnosis: A population-based nested cohort study in Australian Government Department of Veterans' Affairs clients.

    PubMed

    Schaffer, Andrea L; Pearson, Sallie-Anne; Dobbins, Timothy A; Er, Chuang C; Ward, Robyn L; Vajdic, Claire M

    2015-08-01

    Little is known about patterns of care after a cancer of unknown primary (CUP) diagnosis. We performed a retrospective cohort study to describe and compare the treatment, health service use and survival of patients with CUP and metastatic cancer of known primary among 143,956 Australian Government Department of Veterans' Affairs clients, 2004-2007. We randomly matched clients with CUP (C809; n=252) with clients with a first diagnosis of metastatic solid cancer of known primary (n=980). We ascertained health services from the month of diagnosis up to 2 months post-diagnosis for consultations, hospitalizations and emergency department visits, and up to 1 year for treatment. We compared cancer treatments using conditional logistic regression; consultation rates using negative binomial regression; and survival using stratified Cox regression. 30% of CUP patients and 70% of patients with known primary received cancer treatment and the median survival was 37 days and 310 days respectively. CUP patients received fewer cancer medicines (odds ratio (OR)=0.54, 95% confidence interval (CI) 0.33-0.89) and less cancer-related surgery (OR=0.25, 95% CI 0.15-0.41); males with CUP received more radiation therapy (OR=2.88, 95% CI 1.69-4.91). CUP patients had more primary care consultations (incidence rate ratio (IRR)=1.25, 95% CI 1.11-1.41), emergency department visits (IRR=1.86, 95% CI 1.50-2.31) and hospitalizations (IRR=1.18, 95% CI 1.03-1.35), and a higher risk of death within 30 days (hazard ratio=3.30, 95% CI 1.69-6.44). Patients with CUP receive less treatment but use more health services, which may reflect underlying patient and disease characteristics. Copyright © 2015 Commonwealth of Australia. Published by Elsevier Ltd.. All rights reserved.

  18. Investigation on paper cup waste degradation by bacterial consortium and Eudrillus eugeinea through vermicomposting.

    PubMed

    Arumugam, Karthika; Renganathan, Seenivasagan; Babalola, Olubukola Oluranti; Muthunarayanan, Vasanthy

    2018-04-01

    Disposable Paper cups are a threat to the environment and are composed of 90% high strength paper with 5% thin coating of polyethylene. This polyethylene prevents the paper cup from undergoing degradation in the soil. Hence, in the present study two different approaches towards the management of paper cup waste through vermicomposting technology has been presented. The experimental setup includes 2 plastic reactors namely Vermicompost (VC) (Cow dung + Paper cup waste + Earthworm (Eudrillus eugeinea)) and Vermicompost with bacterial consortium (VCB) (Cow dung + Paper cup waste + Eudrillus eugeinea + Microbial consortia such as Bacillus anthracis, B. endophyticus, B. funiculus, B. thuringiensis, B. cereus, B. toyonensis, Virigibacillius chiquenigi, Acinetobacter baumanni and Lactobacillus pantheries). After treatment the physicochemical parameters were analysed. The results showed that the values of TOC (26.52 and 37.47%), TOM (36.01 and 33.13%) and C/N (15.02 and 11.92%) ratio are reduced in both VC and VCB whereas, the values of pH (8.01 and 7.56), EC (1.2-1.9 µs -1 and 1.4-1.9 µs -1 ), TP (46.1 and 51%), TMg (50.52 and 64.3%), TCa (50 and 64%), TNa (1.39 and 1.75%) and TK (1.75 and 1.86%) have increased. This study substantiates the addition of the microbial consortia augmenting the degradation in VCB reactor by reducing the period of process from 19 to 12 weeks. Further the characterisation of the vermicompost prepared from paper cup with FT-IR shows high degradation of carboxylic and aliphatic group; SEM analysis shows the disaggregation of cellulose and lignin; XRD shows the degradation of cellulose. All these analyses endorse the degradation of the paper cup waste faster with microbes (VCB). Thus, this present study high lights management of the paper cup waste in a relatively short period of time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Cervical spinal epidural abscess following acupuncture and wet-cupping therapy: A case report.

    PubMed

    Yao, Yindan; Hong, Wenke; Chen, Huimin; Guan, Qiongfeng; Yu, Hu; Chang, Xianchao; Yu, Yaoping; Xu, Shanhu; Fan, Weinv

    2016-02-01

    Report of an uncommon complication of acupuncture and wet cupping. A 54-year-old man presented with neck pain and fever. Magnetic resonance imaging of the cervical spine revealed an epidural abscess at C4 to T2. The symptoms related to epidural abscess resolved partially after treatment with antibiotics. Acupuncture and wet-cupping therapy should be taken into consideration as a cause of spinal epidural abscesses in patients who present with neck pain and fever. Furthermore, acupuncture and wet-cupping practitioners should pay attention to hygienic measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. PROCESS FOR JACKETING A CORE

    DOEpatents

    Last, G.A.

    1960-07-19

    A process is given for enclosing the uranium core of a nuclear fuel element by placing the core in an aluminum cup and closing the open end of the cup over the core. As the metal of the cup is brought together in a weld over the center of the end of the core, it is extruded inwardly as internal projection into a central recess in the core and outwardly as an external projection. Thus oxide inclusions in the weld of the cup are spread out into the internal and external projections and do not interfere with the integrity of the weld.

  1. Dietary Plans for Carbohydrate Loading

    DTIC Science & Technology

    1989-11-01

    BOIL 0.75 CUP 142.5 GMS FRUIT COCKTAIL-CAN/JUICE 1.50 CUPS 372.0 GMS CIDER- FERMENTED 11.00 FL OZS 330.0 GMS DINNER BEEF-LEAN-SIMMER/ROAST 1.50 SLICES... YOGURT -PLAIN-LOWFAT 1.00 TBSP 14.2 GMS HONEY-STRAINED/EXTRACTED 1.00 TBSP 21.0 GMS RASPBERRIES-CAN/SYRUP 1.00 CUP 256.0 GMS MILK-NONFAT-FLUID 1.00 CUP...CIDER- FERMENTED 11.00 FL OZS 3.30 Gm (1%) LETTUCE-ICEBERG-RAW-LEAVES 1.00 SERVING 2.82 Gm (0%) NUT-WALNUT-PERSIAN/ENGLISH 4.00 TSPS 1.83 Gm (0

  2. Bleeding and cupping.

    PubMed Central

    Turk, J. L.; Allen, E.

    1983-01-01

    Bleeding and cupping have been used in medicine since ancient times in the treatment of fevers and local inflammatory disorders. Local bleeding, by 'wet cupping', was effected by a scarificator or by leeches. John Hunter recommended venesection in moderation but preferred leeches for local bleeding. Bleeding as an accepted therapeutic practice went out of vogue in the middle of the nineteenth century as a result of the introduction of modern scientific methods. Dry cupping and the use of leeches, as counter irritants, persisted until the middle of this century. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:6338802

  3. Evaluation of wet-cupping therapy for persistent non-specific low back pain: a randomised, waiting-list controlled, open-label, parallel-group pilot trial

    PubMed Central

    2011-01-01

    Background Persistent non-specific low back pain (PNSLBP) is one of the most frequently experienced types of back pain around the world. Wet-cupping is a common intervention for various pain conditions, especially in Korea. In this context, we conducted a pilot study to determine the effectiveness and safety of wet-cupping treatment for PNSLBP. Methods We recruited 32 participants (21 in the wet-cupping group and 11 in the waiting-list group) who had been having PNSLBP for at least 3 months. The participants were recruited at the clinical research centre of the Korea Institute of Oriental Medicine, Korea. Eligible participants were randomly allocated to wet-cupping and waiting-list groups. Following the practice of traditional Korean medicine, the treatment group was provided with wet-cupping treatment at two acupuncture points among the BL23, BL24 and BL25 6 times within 2 weeks. Usual care, including providing brochures for exercise, general advice for PNSLBP and acetaminophen, was allowed in both groups. Separate assessors participated in the outcome assessment. We used the 0 to100 numerical rating scale (NRS) for pain, the McGill Pain Questionnaire for pain intensity (PPI) and the Oswestry Disability Questionnaire (ODQ), and we assessed acetaminophen use and safety issues. Results The results showed that the NRS score for pain decreased (-16.0 [95% CI: -24.4 to -7.7] in the wet-cupping group and -9.1 [-18.1 to -0.1] in the waiting-list group), but there was no statistical difference between the groups (p = 0.52). However, the PPI scores showed significant differences between the two groups (-1.2 [-1.6 to -0.8] for the wet-cupping group and -0.2 [-0.8 to 0.4] for the waiting-list group, p < 0.01). In addition, less acetaminophen was used in the wet-cupping group during 4 weeks (p = 0.09). The ODQ score did not show significant differences between the two groups (-5.60 [-8.90 to -2.30] in the wet-cupping group and -1.8 [-5.8 to 2.2] in the waiting-list group, p = 0.14). There was no report of adverse events due to wet-cupping. Conclusion This pilot study may provide preliminary data on the effectiveness and safety of wet-cupping treatments for PNSLBP. Future full-scale randomised controlled trials will be needed to provide firm evidence of the effectiveness of this intervention. Trial Registration ClinicalTrials.gov: (Identifier: NCT00925951) Date of trial registration: June 19th, 2009 The date when the first patient was randomised: July 15th, 2009 The date when the study was completed: November 27th, 2009 PMID:21663617

  4. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    PubMed

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup orientation after THA. · Cup anteversion and inclination should be referenced to the pelvis. · Radiological measurement errors of cup position may be reduced by mathematical concepts. Citation Format · Schwarz TJ, Weber M, Dornia C et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Fortschr Röntgenstr 2017; 189: 864 - 873. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Data Literacy: Real-World Learning through Problem-Solving with Data Sets

    ERIC Educational Resources Information Center

    Erwin, Robin W., Jr.

    2015-01-01

    The achievement of deep learning by secondary students requires teaching approaches that draw students into task commitment, integrated curricula, and analytical thinking. By using real-world data sets in project based instructional units, teachers can guide students in analyzing, interpreting, and reporting quantitative data. Working with…

  6. Helping Disadvantaged Students: Findings from the Thuthuka Programme

    ERIC Educational Resources Information Center

    Barac, Karin

    2015-01-01

    Drawing on social closure theory, this study achieved a deep understanding of the perceptions and experiences of the first cohort of candidates passing through the Thuthuka support programme. Using semi-structured interviews as part of a qualitative approach, currently prevalent modes of professional closure were considered by taking the…

  7. A Study of Undergraduate Students' Alternative Conceptions of Earth's Interior Using Drawing Tasks

    ERIC Educational Resources Information Center

    McAllister, Meredith L.

    2014-01-01

    Learning fundamental geoscience topics such as plate tectonics, earthquakes, and volcanoes requires students to develop a deep understanding of the conceptual models geologists use when describing the structure and dynamics of Earth's interior. Despite the importance of these mental models underlying much of the undergraduate geoscience…

  8. Dance Like a Butterfly

    ERIC Educational Resources Information Center

    Stapp, Alicia; Chessin, Debby; Deason, Rebecca

    2018-01-01

    The authors represent the life cycle of the butterfly through writing, drawing, dance, and math. The Next Generation Science Standards (NGSS) (NGSS Lead States 2013) emphasize college and career readiness as well as critical thinking and problem-solving skills. Students must develop a deep understanding of science concepts and engage in scientific…

  9. Intimacy and Ethical Action in Adult Education

    ERIC Educational Resources Information Center

    Plumb, Donovan

    2009-01-01

    This article suggests that thinking about the nature of intimacy, especially sexual intimacy, is a good way of deepening our understanding of how deep-seated psychic vulnerabilities play an important role in adult education contexts. Drawing on psychoanalytic accounts of human development, the paper outlines how the capacity for ethical action in…

  10. Into the Deep: Mindful Music Learning

    ERIC Educational Resources Information Center

    Lind, Vicki R.

    2014-01-01

    This article outlines strategies for using thinking routines in the general music classroom to foster deeper learning. Based on the Artful Thinking program, a model developed by Harvard's Project Zero in collaboration with Traverse City [Michigan] Area Public Schools, thinking routines were developed to draw students into a more meaningful…

  11. Determination of cup-to-disc ratio of optical nerve head for diagnosis of glaucoma on stereo retinal fundus image pairs

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Nakagawa, Toshiaki; Sawada, Akira; Hatanaka, Yuji; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2009-02-01

    A large cup-to-disc (C/D) ratio, which is the ratio of the diameter of the depression (cup) to that of the optical nerve head (ONH, disc), can be one of the important signs for diagnosis of glaucoma. Eighty eyes, including 25 eyes with the signs of glaucoma, were imaged by a stereo retinal fundus camera. An ophthalmologist provided the outlines of cup and disc on a regular monitor and on the stereo display. The depth image of the ONH was created by determining the corresponding pixels in a pair of images based on the correlation coefficient in localized regions. The areas of the disc and cup were determined by use of the red component in one of the color images and by use of the depth image, respectively. The C/D ratio was determined based on the largest vertical lengths in the cup and disc areas, which was then compared with that by the ophthalmologist. The disc areas determined by the computerized method agreed relatively well with those determined by the ophthalmologist, whereas the agreement for the cup areas was somewhat lower. When C/D ratios were employed for distinction between the glaucomatous and non-glaucomatous eyes, the area under the receiver operating characteristic curve (AUC) was 0.83. The computerized analysis of ONH can be useful for diagnosis of glaucoma.

  12. [Impacts of bleeding and cupping therapy on serum P substance in patients of postherpetic neuralgia].

    PubMed

    Tian, Hao; Tian, Yong-Jing; Wang, Bing; Yang, Li; Wang, Ying-Ying; Yang, Jin-Sheng

    2013-08-01

    To observe the effect of bleeding and cupping therapy on postherpetic neuralgia (PHN) and preliminarily discuss the analgesic mechanism. Sixty-four cases of PHN were randomized into two groups, 32 cases in each one. In the bleeding and cupping group, the local pricking with syringe needle and cupping was applied in the local painful area, once every two days. And totally 8 treatments were required. In the pregabalin group, pregabalin was prescribed for oral administration, 150mg/time, twice a day. And totally 16 days of medication were required. Visual analogue scale (VAS) score and the changes of P substance content in the peripheral and local serum before and after treatment were observed in the two groups. VAS score and peripheral serum P substance after treatment were lower significantly than those before treatment in the two groups (all P<0.01). The result in the bleeding and cupping group was much more significant (P<0.01). The local serum P substance after treatment was reduced significantly than that before treatment in the bleeding and cupping group [(93.86 +/- 9.87) pg/mL vs (46.13 +/- 6.31) pg/mL, P<0.01]. Bleeding and cupping therapy achieves the definite efficacy on PHN and it can reduce significantly peripheral and local serum P substance content in the patients. It is possibly one of the mechanisms of analgesic effect.

  13. The Caenorhabditis elegans mucolipin-like gene cup-5 is essential for viability and regulates lysosomes in multiple cell types.

    PubMed

    Hersh, Bradley M; Hartwieg, Erika; Horvitz, H Robert

    2002-04-02

    The misregulation of programmed cell death, or apoptosis, contributes to the pathogenesis of many diseases. We used Nomarski microscopy to screen for mutants containing refractile cell corpses in a C. elegans strain in which all programmed cell death is blocked and such corpses are absent. We isolated a mutant strain that accumulates refractile bodies resembling irregular cell corpses. We rescued this mutant phenotype with the C. elegans mucolipidosis type IV (ML-IV) homolog, the recently identified cup-5 (coelomocyte-uptake defective) gene. ML-IV is a human autosomal recessive lysosomal storage disease characterized by psychomotor retardation and ophthalmological abnormalities. Our null mutations in cup-5 cause maternal-effect lethality. In addition, cup-5 mutants contain excess lysosomes in many and possibly all cell types and contain lamellar structures similar to those observed in ML-IV cell lines. The human ML-IV gene is capable of rescuing both the maternal-effect lethality and the lysosome-accumulation abnormality of cup-5 mutants. cup-5 mutants seem to contain excess apoptotic cells as detected by staining with terminal deoxynucleotidyltransferase-mediated dUTP nick end labeling. We suggest that the increased apoptosis seen in cup-5 mutants is a secondary consequence of the lysosomal defect, and that abnormalities in apoptosis may be associated with human lysosomal storage disorders.

  14. A new approach for assessment of wear in metal-backed acetabular cups using computed tomography: a phantom study with retrievals.

    PubMed

    Jedenmalm, Anneli; Noz, Marilyn E; Olivecrona, Henrik; Olivecrona, Lotta; Stark, Andre

    2008-04-01

    Polyethylene wear is an important cause of aseptic loosening in hip arthroplasty. Detection of significant wear usually happens late on, since available diagnostic techniques are either not sensitive enough or too complicated and expensive for routine use. This study evaluates a new approach for measurement of linear wear of metal-backed acetabular cups using CT as the intended clinically feasible method. 8 retrieved uncemented metal-backed acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral head into the cup was measured in the CT volumes using dedicated software. Landmark points were placed on the CT images of cup and head, and also on a reference plane in order to calculate the wear vector magnitude and angle to one of the axes. A coordinate-measuring machine was used to test the accuracy of the proposed CT method. For this purpose, the head diameters were also measured by both methods. Accuracy of the CT method for linear wear measurements was 0.6 mm and wear vector angle was 27 degrees . No systematic difference was found between CT scans. This study on explanted acetabular cups shows that CT is capable of reliable measurement of linear wear in acetabular cups at a clinically relevant level of accuracy. It was also possible to use the method for assessment of direction of wear.

  15. Validation of a 3D CT method for measurement of linear wear of acetabular cups.

    PubMed

    Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik

    2011-02-01

    We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

  16. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    PubMed

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  17. A simple technique to strengthen the initial and mid-term to long-term stability of the cup during total hip arthroplasty in developmental dysplasia of the hip.

    PubMed

    Guan, Mingqiang; Zhou, Guanming; Li, Xue

    2018-04-01

    To assess the effects of a technique of cup blocking screws combined with impaction bone grafting during total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH). From August 2011 to July 2015, 53 patients (59 hips) with DDH in our hospital were treated with THA using the technique of cup blocking screws combined with impaction particulate bone grafting. These patients were prospectively followed, and the clinical and imaging results were collected. Harris hip score (HHS) was raised from 41.24 before surgery to 91.49 at the latest follow-up (p less than 0.001). Length discrepancy (LLD) was reduced from 28.97 mm before surgery to 6.08 mm after surgery (p less than 0.001). No loosening of the cup was detected at the last follow-up. The differences were insignificant in cup inclination and rate of cup coverage among the 3 groups of Crowe type II, type III, and type IV DDH (p greater than 0.05). The technique of cup blocking screws combined with impaction particulate bone grafting is simple and reliable, and it not only simplifies the attainment of initial stability, but also strengthens the mid-term to long-term stability during THA in DDH.

  18. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    PubMed

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  19. A technological advance for 21st century obstetricians: the electronically-controlled vacuum extractor.

    PubMed

    Perone, Nicola

    2018-04-25

    To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.

  20. Inter- and intra-observer variability of radiography and computed tomography for evaluation of Zurich cementless acetabular cup placement ex vivo.

    PubMed

    Leasure, Jessica O; Peck, Jeffrey N; Villamil, Armando; Fiore, Kara L; Tano, Cheryl A

    2016-11-23

    To evaluate the inter- and intra-observer variability in measurement of the angle of lateral opening (ALO) and version angle measurement using digital radiography and computed tomography (CT). Each hemipelvis was implanted with a cementless acetabular cup. Ventrodorsal and mediolateral radiographs were made of each pelvis, followed by CT imaging. After removal of the first cup, the pelves were implanted with an acetabular cup in the contralateral acetabulum and imaging was repeated. Three surgeons measured the ALO and version angles three times for each cup from the mediolateral radiographic projection. The same measurements were made using three-dimensional multiplanar reconstructions from CT images. Two anatomical axes were used to measure pelvic inclination in the sagittal plane, resulting in six measurements per cup. Two-way repeated measures analysis of variance evaluated inter- and intra-observer repeatability for radiographic and CT-based measurements. Version angle based on radiographic measurement did not differ within surgeons (p = 0.433), but differed between surgeons (p <0.001). Radiographic measurement of ALO differed within surgeons (p = 0.006) but not between surgeons (p = 0.989). The ALO and version angle measured on CT images did not differ with or between surgeons. Assessment of inter- and intra-observer measurement of ALO and version angle was more reproducible using CT images than conventional mediolateral radiography for a Zurich cementless acetabular cup.

Top