DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanders, R.S.
The effects of heat strip time, heat strip temperature, catalyst ratio, mold cure time, post cure time, and post cure temperature on a hybrid (UCC/SE-54/497XL) cellular silicone molding compound are reported.
Esposito Corcione, Carola; Freuli, Fabrizio; Frigione, Mariaenrica
2014-01-01
The curing reaction of a commercial cold-curing structural epoxy resin, specifically formulated for civil engineering applications, was analyzed by thermal analysis as a function of the curing time and the sample thickness. Original and remarkable results regarding the effects of curing time on the glass transition temperature and on the residual heat of reaction of the cold-cured epoxy were obtained. The influence of the sample thickness on the curing reaction of the cold-cured resin was also deeply investigated. A highly exothermal reaction, based on a self-activated frontal polymerization reaction, was supposed and verified trough a suitable temperature signal acquisition system, specifically realized for this measurement. This is one of the first studies carried out on the curing behavior of these peculiar cold-cured epoxy resins as a function of curing time and thickness. PMID:28788215
Corcione, Carola Esposito; Freuli, Fabrizio; Frigione, Mariaenrica
2014-09-22
The curing reaction of a commercial cold-curing structural epoxy resin, specifically formulated for civil engineering applications, was analyzed by thermal analysis as a function of the curing time and the sample thickness. Original and remarkable results regarding the effects of curing time on the glass transition temperature and on the residual heat of reaction of the cold-cured epoxy were obtained. The influence of the sample thickness on the curing reaction of the cold-cured resin was also deeply investigated. A highly exothermal reaction, based on a self-activated frontal polymerization reaction, was supposed and verified trough a suitable temperature signal acquisition system, specifically realized for this measurement. This is one of the first studies carried out on the curing behavior of these peculiar cold-cured epoxy resins as a function of curing time and thickness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kao, Kai-Chieh; Cheng, Yi-Lung, E-mail: yjcheng@ncnu.edu.tw; Chang, Wei-Yuan
2014-11-01
This study comprehensively investigates the effect of ultraviolet (UV) curing time on the physical, electrical, and reliability characteristics of porous low-k materials. Following UV irradiation for various periods, the depth profiles of the chemical composition in the low-k dielectrics were homogeneous. Initially, the UV curing process preferentially removed porogen-related CH{sub x} groups and then modified Si-CH{sub 3} and cage Si-O bonds to form network Si-O bonds. The lowest dielectric constant (k value) was thus obtained at a UV curing time of 300 s. Additionally, UV irradiation made porogen-based low-k materials hydrophobic and to an extent that increased with UV curing time.more » With a short curing time (<300 s), porogen was not completely removed and the residues degraded reliability performance. A long curing time (>300 s) was associated with improved mechanical strength, electrical performance, and reliability of the low-k materials, but none of these increased linearly with UV curing time. Therefore, UV curing is necessary, but the process time must be optimized for porous low-k materials on back-end of line integration in 45 nm or below technology nodes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulauskas, F.L.
The objective of this work was to investigate the beneficial effect of the variable frequency microwave (VFM) technology to cure thermosetting prepreg laminates. Further, it was to investigate the interrelationship and effect on the curing process of frequency, band width, and curing time with different types of laminates. Previous studies of microwave-assisted curing of neat resins (epoxy) and unidirectional glass and carbon fiber laminates with a fixed frequency of 2.45 GHz, have shown that a substantial reduction in the curing time was obtained. Results of this earlier work indicate that the microwave-assisted curing of multidirectional glass fiber laminates also showmore » a substantial reduction of the required curing time. This may be explained by the penetration of microwave energy directly and throughout the laminate with enhancement of the kinetics of the chemical reaction. The fixed frequency microwave radiation of 2.45 GHz has been demonstrated to be a partially acceptable method to cure unidirectional carbon fiber laminates. Multidirectional carbon fiber/epoxy laminates demonstrate a lack of coupling during the curing process. A direct curing of these laminates was not possible by microwave radiation with the experimental approach used in agreement with previous work. In addition to this short coming, the unidirectional laminate samples cured with the fixed frequency are visually nonuniform. Localized areas of darker colors (burn, hot spots, overheating) are attributed to the formation of standing waves within the microwave cavity. For this reason, the laminates are subject to proper rotation while curing through fixed frequency. The present research indicates that variable frequency microwave technology is a sound and acceptable processing method to effectively cure uni-, bi- or multi-directional thermosetting glass fiber laminates. Also, this methodology will effectively cure unidirectional thermosetting carbon fiber laminates. For all these cases, this technology yielded a substantial reduction in the required cure time of these laminates. Multidirectional carbon fiber laminates demonstrated a lack of coupling of VFM energy during the curing process.« less
Effect of post cure time and temperature on the properties of two phenolic-fiber composites
NASA Technical Reports Server (NTRS)
Lucy, M. H.; Price, H. L.
1975-01-01
Some effects of post-cure time and temperature on the physicomechanical properties of a phenolic-asbestos and a phenolic-glass composite are studied. The molding and post-curing procedures are discussed along with physical and mechanical test results. It is found that the specific gravity of the panels tested decreased slightly but the hardness always increased with post cure, and that the mechanical properties had different patterns of response to increasing post-cure time and temperature. For tensile properties, strength decreased, modulus increased, and elongation at break exhibited little change. In general, the phenolic-asbestos showed more positive response to post cure than did the phenolic-glass. Mold venting is found to impart better properties to the composites concerned.
Effect of long steam curing durations on the strength of A5 concrete.
DOT National Transportation Integrated Search
1976-01-01
Based on the results of this investigation in which the longest steam curing time was 72 hours, it was concluded that increasing the curing times did not adversely affect the strength of the concrete. However, at the later stages of steam curing, gai...
Kopperud, Hilde M; Johnsen, Gaute F; Lamolle, Sébastien; Kleven, Inger S; Wellendorf, Hanne; Haugen, Håvard J
2013-08-01
The latest LED dental curing devices claim sufficient curing of restorative materials with short curing times. This study evaluates mechanical and chemical properties as a function of curing time of two commercial composite filling materials cured with three different LED lamps. The composites were Filtek Z250 (3M ESPE) and Tetric EvoCeram (Ivoclar Vivadent) and the LED curing devices were bluephase 16i (Ivoclar Vivadent), L.E.Demetron II (Kerr) and Mini L.E.D. (Satelec). Control samples were cured with a QTH-lamp (VCL 400, Kerr). The wear resistance after simulated tooth brushing, degree of conversion, curing depth, and amounts of residual monomers were measured after different curing times. The results of this study show that short curing time with high-intensity LEDs may influence the bulk properties of the materials, resulting in lower curing depth and increased residual monomer content. The measured surface properties of the materials, degree of conversion and wear resistance, were not affected by short curing times to the same extent. This study demonstrates that reduced exposure time with high intensity LEDs can result in composite restorations with inferior curing depth and increased leaching of monomers. Dentists are recommended to use sufficient curing times even with high intensity LEDs to ensure adequate curing and minimize the risk of monomer leaching. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Accelerated dry curing of hams.
Marriott, N G; Kelly, R F; Shaffer, C K; Graham, P P; Boling, J W
1985-01-01
Uncured pork legs from the right side of 18 carcasses were treated with a Ross Tenderizer and the left side were controls. All 36 samples were dry-cured for 40, 56 or 70 days and evaluated for appearance traits, cure penetration characteristics, microbial load, Kramer Shear force and taste attributes. The tenderization treatment had no effect (P > 0·05) on visual color or cure penetration rate, weight loss before curing, percentage moisture, nitrate level, nitrite level, total plate count, anaerobic counts, psychrotrophic counts, objective and subjective tenderness measurements or juiciness. However, the higher values of salt suggested a possible acceleration of the dry cure penetration process among the tenderized samples. Cure time had no effect (P > 0·05) on percentage moisture, percentage salt, nitrate content, nitrite content, shear force and juiciness. Results suggest a limited effect of the mechanical tenderization process on certain traits related to dry curing and that total process time should be at least 70 days if color stability during cooking is desired. Copyright © 1985. Published by Elsevier Ltd.
Cure Cycle Optimization of Rapidly Cured Out-Of-Autoclave Composites.
Dong, Anqi; Zhao, Yan; Zhao, Xinqing; Yu, Qiyong
2018-03-13
Out-of-autoclave prepreg typically needs a long cure cycle to guarantee good properties as the result of low processing pressure applied. It is essential to reduce the manufacturing time, achieve real cost reduction, and take full advantage of out-of-autoclave process. The focus of this paper is to reduce the cure cycle time and production cost while maintaining high laminate quality. A rapidly cured out-of-autoclave resin and relative prepreg were independently developed. To determine a suitable rapid cure procedure for the developed prepreg, the effect of heating rate, initial cure temperature, dwelling time, and post-cure time on the final laminate quality were evaluated and the factors were then optimized. As a result, a rapid cure procedure was determined. The results showed that the resin infiltration could be completed at the end of the initial cure stage and no obvious void could be seen in the laminate at this time. The laminate could achieve good internal quality using the optimized cure procedure. The mechanical test results showed that the laminates had a fiber volume fraction of 59-60% with a final glass transition temperature of 205 °C and excellent mechanical strength especially the flexural properties.
Cure Cycle Optimization of Rapidly Cured Out-Of-Autoclave Composites
Dong, Anqi; Zhao, Yan; Zhao, Xinqing; Yu, Qiyong
2018-01-01
Out-of-autoclave prepreg typically needs a long cure cycle to guarantee good properties as the result of low processing pressure applied. It is essential to reduce the manufacturing time, achieve real cost reduction, and take full advantage of out-of-autoclave process. The focus of this paper is to reduce the cure cycle time and production cost while maintaining high laminate quality. A rapidly cured out-of-autoclave resin and relative prepreg were independently developed. To determine a suitable rapid cure procedure for the developed prepreg, the effect of heating rate, initial cure temperature, dwelling time, and post-cure time on the final laminate quality were evaluated and the factors were then optimized. As a result, a rapid cure procedure was determined. The results showed that the resin infiltration could be completed at the end of the initial cure stage and no obvious void could be seen in the laminate at this time. The laminate could achieve good internal quality using the optimized cure procedure. The mechanical test results showed that the laminates had a fiber volume fraction of 59–60% with a final glass transition temperature of 205 °C and excellent mechanical strength especially the flexural properties. PMID:29534048
Effect of CNT addition on cure kinetics of glass fiber/epoxy composite
NASA Astrophysics Data System (ADS)
Fulmali, A. O.; Kattaguri, R.; Mahato, K. K.; Prusty, R. K.; Ray, B. C.
2018-03-01
In present time, developments in reinforced polymer composites have acquired preferential attention for high performance and high precision applications like aerospace, marine and transportation. Fibre reinforced polymer (FRP) composites are being substituted because of their low density, higher strength, stiffness, impact resistance, and improved corrosion resistance. Further laminated composites exhibit superior in-plane mechanical properties that are mostly governed by the fibers. However, laminated FRP composites suffer from poor out of plane properties in some applications. These properties can further be improved by the addition of Nano fillers like carbon nanotube (CNT), graphene and so on. Curing cycle plays a very important role in drawing out the optimum property of glass fiber/epoxy (GE) composite. It is expected that the cure kinetics can further be altered by addition of CNT due to its higher aspect ratio. The main objective of this work is to study the effect of CNT addition on cure kinetics of GE composite as multi-segment adsorption of polymer takes place on the CNT surface. In this study effects of curing parameters on mechanical properties and glass transition temperature of CNT embedded glass fiber/epoxy composite (CNT-GE) has been evaluated. For this study control GE and CNT-GE (with 0.1 wt. %) laminates were fabricated using hand lay-up technique followed by hot compression. The curing parameters that were considered in the present investigation were temperature (80°C, 110°C, and 140°C) and time (0.5 hr, 3 hr and 6 hr). For different combination of above mentioned temperature and time, samples of GE and CNT-GE composites were post cured. Mechanical properties were determined by flexural testing using 3 point bending fixture on INSTRON-5967 and thermal properties i.e. glass transition temperature (Tg) determined by Differential Scanning Calorimeter (DSC) to evaluate the effects of curing parameters. For CNT-GE samples, No much variation observed in flexural modulus with increase in post curing temperature and time, but swift increment was observed in flexural strength at 140°C with increase in post cure time. Elevation in Tg observed with increase in temperature and time duration of post curing; highest Tg noted at 140°C-6hr. Optimum post curing parameters for CNT-GE composite observed to be 140°C-6hr.
Wu, Bin; Li, Ning; Liu, Yi; Huang, Chang-qiong; Zhang, Yong-ling
2006-03-01
To investigate the adverse effects of acupuncture on the prognosis, and effectiveness of acupuncture combined with far infrared ray in the patient of acute Bell's facial paralysis within 48 h. Clinically randomized controlled trial was used, and the patients were divided into 3 groups: group A (early acupuncture group), group B (acupuncture combined with far infrared ray) and group C (acupuncture after 7 days). The facial nerve functional classification at the attack, 7 days after the attack and after treatment, the clinically cured rate of following-up of 6 months, and the average cured time, the cured time of complete facial paralysis were observed in the 3 groups. There were no significant differences among the 3 groups in the facial nerve functional classification 7 days after the attack, the clinically cured rate of following-up of 6 months and the average cured time (P > 0.05), but the cured time of complete facial paralysis in the group A and the group B were shorter than that in the group C (P < 0.05). The patient of acute Bell's facial paralysis can be treated with acupuncture and moxibustion, and traditional moxibustion can be replaced by far infrared way.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulauskas, F.L.; Meek, T.T.
Studies of microwave-assisted curing of neat resins (epoxy) and unidirectional glass and carbon fiber laminates have shown that a substantial reduction in the curing time was obtained. This may be explained by the penetration of microwave energy directly and throughout the laminate with enhancement of the kinetics of the chemical reaction. Results of this work indicate that the microwave assisted curing of glass fiber laminates also shows a substantial reduction of the required curing time. Microwave radiation of 2.45 GHz has been demonstrated to be an acceptable method to cure unidirectional carbon fiber laminates. Also, effective curing of crossply (0/90)more » laminates through this method was observed when proper rotation of the parts accompanied the curing process. This is in accordance with previous work. Multidirectional carbon fiber/epoxy laminates demonstrate a lack of coupling during the curing process. A direct curing of these laminates was not possible by microwave radiation with the experimental approach used, in agreement with previous work. Nevertheless, a moderate reduction in the curing time of these thin laminates was observed due to hybrid curing.« less
Effect of bench time polymerization on depth of cure of dental composite resin
NASA Astrophysics Data System (ADS)
Harahap, K.; Yudhit, A.; Sari, F.
2017-07-01
The aim of this research was to investigate the effect of bench time before light cured polymerization on the depth of cure of dental composite resin. Nanofiller composite resin (Filtek Z350 XT,3M, ESPE,China) was used in this study. Sixty samples of nanofiller composite resin were made and divided into control and test groups with bench time for 0, 15, 30, 45, and 60 min. For the test group, composite resins were stored in refrigerator with 4°C temperatures. Meanwhile, for the control groups, the composite resin was stored at room temperature. The samples were prepared using metal mould with size diameter of 6 mm and 4 mm in thickness. Samples were cured for 20 s by using visible blue light curing unit. Part of samples that unpolymerized were removed by using a plastic spatula. The remaining parts of samples were measured by digital caliper and noted as depth of cure (mm). Data were analyzed to one-way ANOVA and LSD tests (p≤0.05). Results showed there was no significance differences between test groups (p=0.5). A 60 minutes bench time group showed the highest depth of cure value among test group, and it was almost similar with control group value. It can be concluded that longer bench time can increase the depth of cure of composite resin.
Effect of rheological parameters on curing rate during NBR injection molding
NASA Astrophysics Data System (ADS)
Kyas, Kamil; Stanek, Michal; Manas, David; Skrobak, Adam
2013-04-01
In this work, non-isothermal injection molding process for NBR rubber mixture considering Isayev-Deng curing kinetic model, generalized Newtonian model with Carreau-WLF viscosity was modeled by using finite element method in order to understand the effect of volume flow rate, index of non-Newtonian behavior and relaxation time on the temperature profile and curing rate. It was found that for specific geometry and processing conditions, increase in relaxation time or in the index of non-Newtonian behavior increases the curing rate due to viscous dissipation taking place at the flow domain walls.
Differential Curing In Fiber/Resin Laminates
NASA Technical Reports Server (NTRS)
Webster, Charles N.
1989-01-01
Modified layup schedule counteracts tendency toward delamination. Improved manufacturing process resembles conventional process, except prepregs partially cured laid on mold in sequence in degree of partial cure decreases from mold side to bag side. Degree of partial cure of each layer at time of layup selected by controlling storage and partial-curing temperatures of prepreg according to Arrhenius equation for rate of gel of resin as function of temperature and time from moment of mixing. Differential advancement of cure in layers made large enough to offset effect of advance bag-side heating in oven or autoclave. Technique helps prevent entrapment of volatile materials during manufacturing of fiber/resin laminates.
Lian, Zixuan; Qiao, Longshan; Zhu, Guanghong; Deng, Yun; Qian, Bingjun; Yue, Jin; Zhao, Yanyun
2014-03-01
The effects of use of sodium dodecyl sulfate (SDS) pretreatment and 2-stage curing on the microbial, physicochemical, and microstructural qualities of salted duck eggs were studied. After pretreatment in 0.5% (w/v) SDS solution at room conditions for 15 min, no discolorations were observed and no microorganisms were detected on the egg shells. In the 2-stage curing process, 25% (w/v) and 30% (w/v) saline solutions were evaluated in the 1st step (Stage I, approximately 18 d), whereas 4% (w/v) saline solution was applied in the 2nd step (Stage II, approximately 15 d). Along with increased curing time, water content decreased and NaCl content increased in the egg yolks from approximately 0.40% to 0.86%, whereas the water content of egg albumen remained at approximately 85% during the 2-stage curing. More importantly, the NaCl content of albumen maintained at approximately 4.0% at Stage II curing. Yolk index as a sign of maturity for salted duck eggs reached 1 at the end of Stage I (18 d) and retained the same value during Stage II curing regardless of the NaCl concentration in the Stage I saline solution. Oil exudation in egg yolks increased as the time of curing increased. As seen from scanning electron microscopy, oil was released from yolk granules. This study indicated that SDS pretreatment is effective to reduce microbial load on the shells of fresh duck eggs and the 2-stage curing can improve physicochemical qualities of the salted duck eggs and shortened curing time to about 7 to 17 d as compared to the traditional 1-step curing method. Spoiled saline solution and uneven distribution of salt are the 2 major problems in producing salted duck eggs. Sodium dodecyl sulfate (SDS) pretreatment and 2-stage curing process have shown effective to solve these problems, respectively. The SDS pretreatment was able to remove microorganisms and soil from the surface of fresh egg shells, thus preventing the spoilage of the saline solution. The 2-stage curing process successfully controlled the NaCl content of egg albumen and yolk in the final product, and shortened the curing time compared to the traditional 1-step curing method. © 2014 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Mohamed, R.; Nurazzi, N. Mohd; Huzaifah, M.
2017-07-01
This study was conducted to investigate the possibility of utilizing sludge palm oil (SPO) as processing oil, with various amount of carbon black as its reinforcing filler, and its effects on the curing characteristics and mechanical properties of natural rubber/styrene butadiene rubber (NR/SBR) compound. Rubber compound with fixed 15 pphr of SPO loading, and different carbon black loading from 20 to 50 pphr, was prepared using two roll mills. The cure characteristics and mechanical tests that have been conducted are the scorch and cure time analysis, tensile strength and tear strength. Scorch time (ts5) and cure time (t90) of the compound increases with the increasing carbon black loading. The mechanical properties of NR/SBR compound viz. the tensile strength, modulus at 300% strain and tear strength were also improved by the increasing carbon black loading.
Network Formation in Piperidine-Cured Epoxy and Epoxy-Rubber Systems: Effects of Cure Time.
NASA Astrophysics Data System (ADS)
D'Oyen, Raquel M.; Carr, Stephen H.
1996-03-01
The system, piperidine-cured diglycidyl ether of bisphenol-A (DGEBA) to which various amounts of carboxyl terminated acrylonitrile-butadiene (CTBN) have been added, is used as a model rubber modified thermoset. The glass transition temperatures (T_g) of a low molecular weight (374 g/eq) epoxy, cured with piperidine at 120 degC, have been measured by differential scanning calorimetry in order to follow the curing process. The maximum Tg is found after curing for 16 hours. Systems that have been modified with varied concentrations of an adducted CTBN, also show Tg maxima at this time. Addition of 5-20in long-time T_gs, indicating complete segregation of the rubber. The T_gs of the CTBN modified systems at short times are higher than in the unmodified epoxy. This acceleration of the initial stage of cure indicates that the CTBN acts as a diluent, increasing the initial rate of reaction by changing the mobility of the reactive sites. The mechanical properties--toughness, yield and modulus--are related to the CTBN content and to the degree of cure of the system.
Clinical effect of reducing curing times with high-intensity LED lights
Ward, Justin D.; Wolf, Bethany J.; Leite, Luis P.; Zhou, Jing
2016-01-01
Objective To evaluate the clinical performance of brackets cured with a high-intensity, light-emitting diode (LED) with a shorter curing time. Materials and Methods Thirty-four patients and a total of 680 brackets were examined using a randomized split-mouth design. The maxillary right and mandibular left quadrants were cured for 6 seconds with a high-intensity LED light (3200 mW/cm2) and the maxillary left and mandibular right quadrants were cured for 20 seconds with a standard-intensity LED light (1200 mW/cm2). Alternating patients had the quadrants inverted for the curing protocol. The number and date of each first-time bracket failure was recorded from 199 to 585 days posttreatment. Results The bracket failure rate was 1.18% for both curing methods. The proportion of bracket failure was not significantly different between curing methods (P = 1.000), genders (P = 1.000), jaws (P = .725), sides (P = .725), or quadrants (P = .547). Posterior teeth exhibited a greater proportion of failures (2.21%) relative to anterior teeth (0.49%), although the difference was not statistically significant (P = .065). Conclusions No difference was found in bond failure rates between the two curing methods. Both methods showed bond failure rates low enough to be considered clinically sufficient. The high-intensity LED light used with a shorter curing time may be considered an advantage due to the reduced chair time. PMID:25760887
Temperature and curing time affect composite sorption and solubility
de CASTRO, Fabrício Luscino Alves; CAMPOS, Bruno Barbosa; BRUNO, Kely Firmino; REGES, Rogério Vieira
2013-01-01
Objective: This study evaluated the effect of temperature and curing time on composite sorption and solubility. Material and Methods: Seventy five specimens (8x2 mm) were prepared using a commercial composite resin (ICE, SDI). Three temperatures (10º C, 25º C and 60º C) and five curing times (5 s, 10 s, 20 s, 40 s and 60 s) were evaluated. The specimens were weighed on an analytical balance three times: A: before storage (M1); B: 7 days after storage (M2); C: 7 days after storage plus 1 day of drying (M3). The storage solution consisted of 75% alcohol/25% water. Sorption and solubility were calculated using these three weights and specimen dimensions. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U Tests (α=5%). Results: The results showed that time, temperature and their interaction influenced the sorption and solubility of the composite (p<0.05). At 60º C, the composite sorption showed an inverse relationship with the curing time (p<0.05). The composite cured for 5 s showed higher sorption for the 40 s or 60 s curing times when compared with all temperatures (p<0.05). Curing times of 20 s and 40 s showed similar sorption data for all temperatures (p>0.05). The 60º C composite temperature led to lower values of sorption for all curing times when compared with the 10º C temperature (p<0.05). The same results were found when comparing 10º C and 25º C (p<0.05), except that the 20 s and 40 s curing times behaved similarly (p>0.05). Solubility was similar at 40 s and 60 s for all temperatures (p>0.05), but was higher at 10º C than at 60º C for all curing times (p<0.05). When the composite was cured at 25º C, similar solubility values were found when comparing the 5 s and 10 s or 20 s and 40 s curing times (p>0.05). Conclusion: In conclusion, higher temperatures or longer curing times led to lower sorption and solubility values for the composite tested; however, this trend was only significant in specific combinations of temperature and curing times. PMID:23739853
Arano, Ichiro; Sugimoto, Tomoyuki; Hamasaki, Toshimitsu; Ohno, Yuko
2010-04-23
Survival analysis methods such as the Kaplan-Meier method, log-rank test, and Cox proportional hazards regression (Cox regression) are commonly used to analyze data from randomized withdrawal studies in patients with major depressive disorder. However, unfortunately, such common methods may be inappropriate when a long-term censored relapse-free time appears in data as the methods assume that if complete follow-up were possible for all individuals, each would eventually experience the event of interest. In this paper, to analyse data including such a long-term censored relapse-free time, we discuss a semi-parametric cure regression (Cox cure regression), which combines a logistic formulation for the probability of occurrence of an event with a Cox proportional hazards specification for the time of occurrence of the event. In specifying the treatment's effect on disease-free survival, we consider the fraction of long-term survivors and the risks associated with a relapse of the disease. In addition, we develop a tree-based method for the time to event data to identify groups of patients with differing prognoses (cure survival CART). Although analysis methods typically adapt the log-rank statistic for recursive partitioning procedures, the method applied here used a likelihood ratio (LR) test statistic from a fitting of cure survival regression assuming exponential and Weibull distributions for the latency time of relapse. The method is illustrated using data from a sertraline randomized withdrawal study in patients with major depressive disorder. We concluded that Cox cure regression reveals facts on who may be cured, and how the treatment and other factors effect on the cured incidence and on the relapse time of uncured patients, and that cure survival CART output provides easily understandable and interpretable information, useful both in identifying groups of patients with differing prognoses and in utilizing Cox cure regression models leading to meaningful interpretations.
Cure rate model with interval censored data.
Kim, Yang-Jin; Jhun, Myoungshic
2008-01-15
In cancer trials, a significant fraction of patients can be cured, that is, the disease is completely eliminated, so that it never recurs. In general, treatments are developed to both increase the patients' chances of being cured and prolong the survival time among non-cured patients. A cure rate model represents a combination of cure fraction and survival model, and can be applied to many clinical studies over several types of cancer. In this article, the cure rate model is considered in the interval censored data composed of two time points, which include the event time of interest. Interval censored data commonly occur in the studies of diseases that often progress without symptoms, requiring clinical evaluation for detection (Encyclopedia of Biostatistics. Wiley: New York, 1998; 2090-2095). In our study, an approximate likelihood approach suggested by Goetghebeur and Ryan (Biometrics 2000; 56:1139-1144) is used to derive the likelihood in interval censored data. In addition, a frailty model is introduced to characterize the association between the cure fraction and survival model. In particular, the positive association between the cure fraction and the survival time is incorporated by imposing a common normal frailty effect. The EM algorithm is used to estimate parameters and a multiple imputation based on the profile likelihood is adopted for variance estimation. The approach is applied to the smoking cessation study in which the event of interest is a smoking relapse and several covariates including an intensive care treatment are evaluated to be effective for both the occurrence of relapse and the non-smoking duration. Copyright (c) 2007 John Wiley & Sons, Ltd.
Use of near-IR to monitor the influence of external heating on dental composite photopolymerization.
Trujillo, Marianela; Newman, Sheldon M; Stansbury, Jeffrey W
2004-10-01
This study was conducted to determine the effect of modest external heating on the photopolymerization kinetics and conversion of commercial dental composite restorative materials. A transmission-mode, real-time near-infrared spectroscopic technique was used to monitor the photopolymerization process in the composite materials at various temperatures between 23 and 70 degrees C. Several light curing units, differing in spectral output and power densities were compared at the different cure temperatures. Several significantly different commercial composites were compared for their response. Regardless of the curing light or composite material used, photopolymerization at a moderate curing temperature of 54.5 degrees C resulted in significantly higher immediate and final conversion values compared with room temperature photocuring. Contrary to the room temperature cured materials, at the elevated cure temperature the extent of post-cure was minor and different curing lights produced very uniform conversion values within a given material. The time required to reach a given level of conversion, established as full conversion with the room temperature cure, was reduced typically by 80-90% using the elevated curing conditions. Complementary kinetic studies confirmed the effect of cure temperature on increasing the polymerization rate in dental composites as significant. Increasing the temperature of composite resin within potentially biologically compatible limits can significantly influences resin polymerization. These increased rates and conversion could lead to improved properties of composite restorative materials.
Evaluation of curing compound application time on concrete surface durability.
DOT National Transportation Integrated Search
2015-03-01
The effect of curing compound application time after concrete finishing was examined in the study. Times of 30 minutes, 2 hours and 4 hours were considered and repeatability was evaluated with comparisons to a Phase I portion of the study. Scaling re...
2014-01-01
Background The aim of this study is to compare the microleakage of Class II dental composite resin restorations which have been cured by three different LED (light emitting diode) light curing modes compared to control samples cured by QTH (quartz tungsten halogen) light curing units (LCUs), to determine the most effective light curing unit and mode of curing. Results In this experimental study, class II cavities were prepared on 100 sound human premolars which have been extracted for orthodontic treatment. The teeth were randomly divided into four groups; three experimental and one control group of 25 teeth each. Experimental groups were cured by either conventional, pulse-delay, or ramped curing modes of LED. The control group was cured for 20 seconds by QTH. The restorations were thermocycled (1000 times, between 5 and 55°C, for 5 seconds dwell time), dyed, sectioned mesio-distally and viewed under stereo-microscope (40×) magnification. Teeth were then scored on a 0 to 4 scale based on the amount of microleakage. The data were analyzed by Chi-square test. No significant difference was demonstrated between the different LCUs (light curing units), or modes of curing, at the enamel side (p > 0.05). At the dentin side, all modes of LED curing could significantly reduce microleakage (p < 0.05). The results suggest that slow start curing improves marginal integrity and seal. High intense curing endangers those aims. Conclusions Comparison between the three LED mode cured composite resin restorations and QTH curing showed LED curing in all modes is more effective than QTH for reducing microleakage. Both LED and QTH almost completely eliminate the microleakage on the enamel side, however none of them absolutely eliminated microleakage on the dentin side. PMID:24990296
Howland, Harris; Fahmy, Raafat; Hoag, Stephen W
2015-01-01
For controlled release, latex or pseudolatex coatings to function as designed, it must be cured at temperatures at or slightly above the polymer's glass transition temperature. The focus of this study is to develop an understanding of the curing process and to develop near infrared spectroscopy as a tool for monitoring curing. Differential scanning calorimetry studies were used to determine how the thermal properties of glyceryl monostearate (GMS) and its polymorphic forms relate to the extent of Eudragit® polymer coat curing at different curing temperatures. The different GMS melting endotherms were used to monitor the extent of curing and as references for model development. The calculated melting peak areas for the GMS were plotted versus time and found to be dependent on time and temperature used for curing. Principal component analysis and parallel factor analysis were used to investigate the effect of curing on the films and showed that spectral changes could be could be directly related to the changes associated with the GMS during curing. Partial least square models developed could predict the extent of curing and the final state of GMS post curing.
Warpage of QFN Package in Post Mold Cure Process of integrated circuit packaging
NASA Astrophysics Data System (ADS)
Sriwithoon, Nattha; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon
2017-09-01
This research studied about warpage of QFN package in post mold cure process of integrated circuit (IC) packages using pre-plated (PPF) leadframe. For IC package, epoxy molding compound (EMC) are molded by cross linking of compound stiffness but incomplete crosslinked network and leading the fully cured thermoset by post mold cure (PMC) process. The cure temperature of PMC can change microstructure of EMC in term of stress inside the package and effect to warpage of the package due to coefficient of thermal expansion (CTE) between EMC and leadframe. In experiment, cure temperatures were varied to check the effect of internal stress due to different cure temperature after completed post mold cure for TDFN 2×3 8L. The cure temperature were varied with 180 °C, 170 °C, 160 °C, and 150°C with cure time 4 and 6 hours, respectively. For analysis, the TDFN 2×3 8L packages were analyzed the warpage by thickness gauge and scanning acoustic microscope (SAM) after take the test samples out from the oven cure. The results confirmed that effect of different CTE between EMC and leadframe due to different cure temperature resulting to warpage of the TDFN 2×3 8L packages.
Effect of mold diameter on the depth of cure of a resin-based composite material.
Erickson, Robert L; Barkmeier, Wayne W
2017-02-01
The purpose of this study was to examine the effect of mold diameter on depth of cure of a resin-based composite material for varying amounts of irradiation. A resin-based composite was light-cured for 10-80 s in stainless-steel molds of either 6 mm or 4 mm in diameter and then dark-stored for 24 h. Specimens were then scraped back and the length of the cured specimens was measured to provide depth of cure (D SB ). Radiant exposure to each of the mold diameters was determined by measuring the power. The D SB values using the 4-mm molds were lower than those of the 6-mm molds. The average difference between the two groups for each irradiation time was 0.45 ± 0.02 mm. A fixed depth of cure required about 39% more irradiation time for the 4-mm mold than for the 6-mm mold but 75% more radiant exposure. The difference in cure depth for a fixed radiant exposure was 0.79 mm. A better comparison of depth of cure is obtained by using identical radiant exposures for different mold diameters. It is believed that greater loss of light by absorption at the stainless-steel cylinder walls for the 4-mm-diameter cylinders accounts for the lower depth of cure when compared with the 6-mm molds. © 2017 Eur J Oral Sci.
Intravascular low-intensity He-Ne laser irradiation therapy on idiopathic edema
NASA Astrophysics Data System (ADS)
Gao, Yunqing; Liu, T. C.; Tang, Xiang-Jun
1998-11-01
194 patients with psoriasis were treated by intravascular low level laser irradiation combined with Vit C 2.0g iv and O2 inhale to the nose. An hour once a day, for 5-40 times, and 13.06 times in average, ten times with 4-7 days intervals. The results: cured 23 cases, good effected 61 cases, improved 110 cases, relapsed 10 cases. Curative effect was related to treatment times, cured and good effected 5 times 12.5 percent, 10 times 31 percent, 15 times 94 percent. A matched control group in 17 patients was treated by drug. The results: good effected 1 case, improved 13 cases, not effected 3 cases.
Curing mode affects bond strength of adhesively luted composite CAD/CAM restorations to dentin.
Lührs, Anne-Katrin; Pongprueksa, Pong; De Munck, Jan; Geurtsen, Werner; Van Meerbeek, Bart
2014-03-01
To determine the effect of curing mode and restoration-surface pre-treatment on the micro-tensile bond strength (μTBS) to dentin. Sandblasted CAD/CAM composite blocks (LAVA Ultimate, 3M ESPE) were cemented to bur-cut dentin using either the etch & rinse composite cement Nexus 3 ('NX3', Kerr) with Optibond XTR ('XTR', Kerr), or the self-etch composite cement RelyX Ultimate ('RXU', 3M ESPE) with Scotchbond Universal ('SBU', 3M ESPE). All experimental groups included different 'curing modes' (light-curing of adhesive and cement ('LL'), light-curing of adhesive and auto-cure of cement ('LA'), co-cure of adhesive through light-curing of cement ('AL'), or complete auto-cure ('AA')) and different 'restoration-surface pre-treatments' of the composite block (NX3: either a silane primer (Kerr), or the XTR adhesive; RXU: either silane primer (RelyX Ceramic Primer, 3M ESPE) and SBU, or solely SBU). After water-storage (7 days, 37°C), the μTBS was measured. Additionally, the degree of conversion (DC) of both cements was measured after 10min and after 1 week, either auto-cured (21°C/37°C) or light-cured (directly/through 3-mm CAD/CAM composite). The linear mixed-effects model (α=0.05) revealed a significant influence of the factors 'curing mode' and 'composite cement', and a less significant effect of the factor 'restoration-surface pre-treatment'. Light-curing 'LL' revealed the highest μTBS, which decreased significantly for all other curing modes. For curing modes 'AA' and 'AL', the lowest μTBS and a high percentage of pre-testing failures were reported. Overall, DC increased with light-curing and incubation time. The curing mode is decisive for the bonding effectiveness of adhesively luted composite CAD/CAM restorations to dentin. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Krömker, Volker; Zinke, Claudia; Paduch, Jan-Hendrik; Klocke, Doris; Reimann, Anette; Eller, Georg
2010-02-01
This field study focused on the possible effects of increased milking frequency (milking four times a day in comparison with milking twice a day) on clinical and bacteriological cure rates of clinical, antibiotically treated mastitis cases. Parameters tested were clinical, microbiological and full (cytomicrobiological) cure as well as the development of milk yield after the clinical mastitis episode. Cows from a large dairy herd meeting the study criteria (n=93) were assigned to two treatment groups by a systematic randomization scheme (blocked by body temperature <=or >39.5 degrees C). Both groups were randomly divided by experimental treatments: a) antibiotic intramammary treatment and milking 2-times a day; b) antibiotic intramammary treatment and milking 4-times a day. Treatments were initiated before the culture results were known. Cows were surveyed and evaluated on days 1-6, 24 and 31. No significant differences between treatment and control groups regarding clinical cure, microbiological cure, full cure and milk production could be established. Applying a 4-times a day milking regime did not lead to any significant effect, either positive or negative. Therefore, the results suggest that milking 4-times a day as a supporting therapy for mild, moderate and severe antimicrobially treated mastitis cases cannot be recommended.
Effects of Temperature and Humidity on Wilethane 44 Cure
DOE Office of Scientific and Technical Information (OSTI.GOV)
John C. Weigle
Wilethane 44 is a polyurethane adhesive developed by the Materials Team within ESA-MEE at Los Alamos National Laboratory as a replacement for Hexcel Corporation Urethane 7200. Urethane 7200 is used in numerous weapon systems, but it was withdrawn from the market in 1989. The weapons complex requires a replacement material for use in the W76-1 LEP and the W88, as well as for assembly of JTAs for other warheads. All polyurethane systems are susceptible to moisture reacting with unreacted isocyanate groups. This side reaction competes with the curing reaction and results in CO{sub 2} formation. Therefore, a polyurethane adhesive canmore » exhibit foaming if appropriate environmental controls are not in place while it cures. A designed experiment has been conducted at TA-16-304 to determine the effects of ambient conditions on the properties of cured Wilethane 44. Temperature was varied from 15 C to 30 C and relative humidity from 15% to 40%. The density, hardness at 24 hours, and butt tensile strength on aluminum substrates were measured and fitted to quadratic equations over the experimental space. Additionally, the loss and storage moduli during cure were monitored as a function of cure temperature. These experiments provide a stronger basis for establishing appropriate environmental conditions and cure times when using Wilethane 44. The current guidelines are a working time of 90 minutes, a cure time of 18 hours, and a relative humidity of less than 25%, regardless of ambient temperature. Viscosity measurements revealed that the working time is a strong function of temperature and can be as long as 130 minutes at 15 C or as short as 90 minutes at 30 C. The experiments also showed that the gel time is much longer than originally thought, as long as 13 hours at 15 C. Consequently, it may be necessary to extend the required cure time at temperatures below 20 C. Allowable humidity varies as a function of temperature from 34% at 15 C to 15% at 30 C.« less
Effect of commercially available egg cures on the survival of juvenile salmonids
Clements, S.; Chitwood, R.; Schreck, C.B.
2011-01-01
There is some concern that incidental consumption of eggs cured with commercially available cures for the purpose of sport fishing causes mortality in juvenile salmon. We evaluated this by feeding juvenile spring Chinook (Oncorhynchus tshawytscha) and steelhead (O. mykiss) with eggs cured with one of five commercially available cures. We observed significant levels of mortality in both pre-smolts and smolts. Depending on the experiment, 2, 3, or 4 of the cures were associated with mortality. Mortality tended to be higher in the smolts than in the parr, but there was no clear species effect. The majority of mortality occurred within the first 10 d of feeding. Removal of sodium sulfite from the cure significantly reduced the level of mortality. Soaking the eggs prior to feeding did not reduce mortality. We observed a clear relationship between the amount of cured egg consumed each day and the survival time. We conclude that consumption of eggs cured with sodium sulfite has the potential to cause mortality in juvenile steelhead and Chinook salmon in the wild.
Effect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power led
ERGUN, Gulfem; EGILMEZ, Ferhan; YILMAZ, Sukran
2011-01-01
Objective Applications of resin luting agents and high-power light-emitting diodes (LED) light-curing units (LCUs) have increased considerably over the last few years. However, it is not clear whether the effect of reduced exposure time on cytotoxicity of such products have adequate biocompatibility to meet clinical success. This study aimed at assessing the effect of reduced curing time of five resin luting cements (RLCs) polymerized by high-power LED curing unit on the viability of a cell of L-929 fibroblast cells. Material and Methods Disc-shaped samples were prepared in polytetrafluoroethylene moulds with cylindrical cavities. The samples were irradiated from the top through the ceramic discs and acetate strips using LED LCU for 20 s (50% of the manufacturer's recommended exposure time) and 40 s (100% exposure time). After curing, the samples were transferred into a culture medium for 24 h. The eluates were obtained and pipetted onto L-929 fibroblast cultures (3x104 per well) and incubated for evaluating after 24 h. Measurements were performed by dimethylthiazol diphenyltetrazolium assay. Statistical significance was determined by two-way ANOVA and two independent samples were compared by t-test. Results Results showed that eluates of most of the materials polymerized for 20 s (except Rely X Unicem and Illusion) reduced to a higher extent cell viability compared to samples of the same materials polymerized for 40 s. Illusion exhibited the least cytotoxicity for 20 s exposure time compared to the control (culture without samples) followed by Rely X Unicem and Rely X ARC (90.81%, 88.90%, and 83.11%, respectively). For Rely X ARC, Duolink and Lute-It 40 s exposure time was better (t=-1.262 p=0,276; t=-9.399 p=0.001; and t=-20.418 p<0.001, respectively). Conclusion The results of this study suggest that reduction of curing time significantly enhances the cytotoxicity of the studied resin cement materials, therefore compromising their clinical performance. PMID:21625748
Polymerization of a dual-cured cement through ceramic: LED curing light vs halogen lamp.
Lopes, Lawrence Gonzaga; Franco, Eduardo Batista; Name Neto, Abrão; Herrera, Francyle S; Kurachi, Cristina; Castañeda-Espinosa, Juan C; Lauris, José Roberto Pereira
2004-12-01
The aim of this study was to investigate the influence of light source, LED unit and halogen lamp (HL), on the effectiveness of Enforce dual-cured cement cured under a ceramic disc. Three exposure times (60, 80 and 120 s) were also evaluated. Two experimental groups, in which the polymerization of the dual-cured cement was performed through a ceramic disc, and two control groups, in which the polymerization of the dual-cured cement was performed directly without presence of ceramic disc were subdivided into three subgroups (three different exposure times), with five specimens each: G1A- HL 60s; G1B- HL 80s; G1C- HL 120s; G2A- LED 60s; G2B- LED 80s; G2C- LED 120s; and control groups: G3A- HL 60s; G3B- HL 80s; G3C- HL 120s; G4A- LED 60s; G4B- LED 80s and G4C- LED 120s. Cement was applied in a steel matrix (4mm diameter, 1.2mm thickness). In the experimental groups, a ceramic disc was placed on top. The cement was light-cured through the ceramic by a HL and LED, however, the control groups were cured without the ceramic disc. The specimens were stored in a light-proof container at 37ºC for 24 hours, then Vickers hardness was determined. A four-way ANOVA and Tukey test (p£ 0.05) were performed. All specimens cured by LED for 60s showed inferior values compared with the halogen groups. In general, light-curing by LED for 80s and 120s was comparable to halogen groups (60s and 80s) and their control groups. LED technology can be viable for light-curing through conventional ceramic indirect restorations, when curing time is increased in relation to HL curing time.
Viswanathan, R; Shashibhushan, K K; Subba Reddy, V V
2011-12-01
To evaluate and compare shear bond strengths of composite resins to primary enamel and dentine when the adhesives are pre-cured (light cured before the application of the resin) or co-cured (adhesive and the resin light cured together). Buccal surfaces of 80 caries-free primary molars were wet ground to create bonding surfaces on enamel and dentine and specimens mounted on acrylic blocks. Two bonding agents (Prime and Bond NT® and Xeno III®) were applied to either enamel or dentine as per manufacturer's instructions. In 40 specimens, the bonding agent was light cured immediately after the application (pre-cured). The other 40 specimens were not light cured until the composite resin application (co-cured). Resin composite cylinders were made incrementally using acrylic moulds over the adhesives and light cured. Specimens were stored in deionised water for 24 hours at room temperature. Shear bond strength was measured using an Instron universal testing machine (in MPa) and was analysed with Student's unpaired t test. Light curing the adhesive separately produced significantly higher bond strengths to primary dentine than co-curing (p<0.001). At the same time light curing the adhesive separately did not produce significantly different bond strengths to primary enamel (p>0.05). Curing sequence had no significant effect on shear bond strength of adhesives on the primary enamel. Pre-curing adhesives before curing composite resins produced greater shear bond strength to primary dentine.
Time scales of radiation damage decay in four optical materials
NASA Astrophysics Data System (ADS)
Grupp, Frank; Geis, Norbert; Katterloher, Reinhard; Bender, Ralf
2017-09-01
In the framework of the qualification campaigns for the near infrared spectrometer and photometer instrument (NISP) on board the ESA/EUCLID satellite six optical materials where characterized with respect to their transmission losses after a radiation dose representing the mission exposure to high energy particles in the outer Lagrange point L2. Data was taken between 500 and 2000nm on six 25mm thick coated probes. Thickness and coating being representative for the NISP flight configuration. With this paper we present results owing up the radiation damage shown in [1]. We where able to follow up the decay of the radiation damage over almost one year under ambient conditions. This allows us to distinguish between curing effects that happen on different time-scales. As for some of the materials no radiation damage and thus no curing was detected, all materials that showed significant radiation damage in the measured passband showed two clearly distinguished time scales of curing. Up to 70% of the transmission losses cured on half decay time scales of several tens of days, while the rest of the damage cures on time scales of years.
Effect of Strength Enhancement of Soil Treated with Environment-Friendly Calcium Carbonate Powder
Park, Kyungho; Jun, Sangju; Kim, Daehyeon
2014-01-01
This study aims to investigate the effects of the strength improvement of soft ground (sand) by producing calcium carbonate powder through microbial reactions. To analyze the cementation effect of calcium carbonate produced through microbial reaction for different weight ratios, four different types of specimens (untreated, calcium carbonate, cement, and calcium carbonate + cement) with different weight ratios (2%, 4%, 6%, and 8%) were produced and cured for a period of 3 days, 7 days, 14 days, 21 days, and 28 days to test them. The uniaxial compression strength of specimens was measured, and the components in the specimen depending on the curing period were analyzed by means of XRD analysis. The result revealed that higher weight ratios and longer curing period contributed to increased strength of calcium carbonate, cement, and calcium carbonate + cement specimens. The calcium carbonate and the calcium carbonate + cement specimens in the same condition showed the tendency of decreased strength approximately 3 times and two times in comparison with the 8% cement specimens cured for 28 days, but the tendency of increased strength was approximately 4 times and 6 times in comparison with the untreated specimen. PMID:24688401
Effect of strength enhancement of soil treated with environment-friendly calcium carbonate powder.
Park, Kyungho; Jun, Sangju; Kim, Daehyeon
2014-01-01
This study aims to investigate the effects of the strength improvement of soft ground (sand) by producing calcium carbonate powder through microbial reactions. To analyze the cementation effect of calcium carbonate produced through microbial reaction for different weight ratios, four different types of specimens (untreated, calcium carbonate, cement, and calcium carbonate + cement) with different weight ratios (2%, 4%, 6%, and 8%) were produced and cured for a period of 3 days, 7 days, 14 days, 21 days, and 28 days to test them. The uniaxial compression strength of specimens was measured, and the components in the specimen depending on the curing period were analyzed by means of XRD analysis. The result revealed that higher weight ratios and longer curing period contributed to increased strength of calcium carbonate, cement, and calcium carbonate + cement specimens. The calcium carbonate and the calcium carbonate + cement specimens in the same condition showed the tendency of decreased strength approximately 3 times and two times in comparison with the 8% cement specimens cured for 28 days, but the tendency of increased strength was approximately 4 times and 6 times in comparison with the untreated specimen.
Enayatifard, Reza; Mahjoob, Aiding; Ebrahimi, Pouneh; Ebrahimnejad, Pedram
2015-01-01
Objective(s): A Box-Behnken design was used for evaluation of Eudragit coated diclofenac pellets. The purpose of this work was to optimize diclofenac pellets to improve the physicochemical properties using experimental design. Materials and Methods: Diclofenac was loaded onto the non-pareil beads using conventional coating pan. Film coating of pellets was done at the same pan. The effect of plasticizer level, curing temperature and curing time was determined on the release of diclofenac from pellets coated with polymethacrylates. Results: Increasing the plasticizer in the coating formula led to decrease in drug release and increasing the curing temperature and time resulted in higher drug release. The optimization process generated an optimum of 35% drug release at 3 hr. The level of plasticizer concentration, curing temperature and time were 20% w/w, 55 °C and 24 hr, respectively. Conclusion: This study showed that by controllinig the physical variables optimum drug release were obtained. PMID:26351563
Tracking Polymer Cure Via Embedded Optical Fibers
NASA Technical Reports Server (NTRS)
Dean, David L.; Davidson, T. Fred
1993-01-01
Fourier-transform infrared spectroscopy applied in interior of specimen of material by bringing infrared light through specimen in optical fiber. Light interacts with material via evanescent-wave effect. Spectra obtained in this way at various times during curing process also combined with data from ultrasonic, thermographic, and dielectric-impedance monitoring, and other measurement techniques to obtain more complete characterization of progress of curing process.
A new approach to estimate time-to-cure from cancer registries data.
Boussari, Olayidé; Romain, Gaëlle; Remontet, Laurent; Bossard, Nadine; Mounier, Morgane; Bouvier, Anne-Marie; Binquet, Christine; Colonna, Marc; Jooste, Valérie
2018-04-01
Cure models have been adapted to net survival context to provide important indicators from population-based cancer data, such as the cure fraction and the time-to-cure. However existing methods for computing time-to-cure suffer from some limitations. Cure models in net survival framework were briefly overviewed and a new definition of time-to-cure was introduced as the time TTC at which P(t), the estimated covariate-specific probability of being cured at a given time t after diagnosis, reaches 0.95. We applied flexible parametric cure models to data of four cancer sites provided by the French network of cancer registries (FRANCIM). Then estimates of the time-to-cure by TTC and by two existing methods were derived and compared. Cure fractions and probabilities P(t) were also computed. Depending on the age group, TTC ranged from to 8 to 10 years for colorectal and pancreatic cancer and was nearly 12 years for breast cancer. In thyroid cancer patients under 55 years at diagnosis, TTC was strikingly 0: the probability of being cured was >0.95 just after diagnosis. This is an interesting result regarding the health insurance premiums of these patients. The estimated values of time-to-cure from the three approaches were close for colorectal cancer only. We propose a new approach, based on estimated covariate-specific probability of being cured, to estimate time-to-cure. Compared to two existing methods, the new approach seems to be more intuitive and natural and less sensitive to the survival time distribution. Copyright © 2018 Elsevier Ltd. All rights reserved.
Factors affecting dry-cured ham consumer acceptability.
Morales, R; Guerrero, L; Aguiar, A P S; Guàrdia, M D; Gou, P
2013-11-01
The objectives of the present study were (1) to compare the relative importance of price, processing time, texture and intramuscular fat in purchase intention of dry-cured ham through conjoint analysis, (2) to evaluate the effect of dry-cured ham appearance on consumer expectations, and (3) to describe the consumer sensory preferences of dry-cured ham using external preference mapping. Texture and processing time influenced the consumer preferences in conjoint analysis. Red colour intensity, colour uniformity, external fat and white film presence/absence influenced consumer expectations. The consumer disliked hams with bitter and metallic flavour and with excessive saltiness and piquantness. Differences between expected and experienced acceptability were found, which indicates that the visual preference of consumers does not allow them to select a dry-cured ham that satisfies their sensory preferences of flavour and texture. Copyright © 2013 Elsevier Ltd. All rights reserved.
Heravi, Farzin; Moazzami, Saied Mostafa; Ghaffari, Negin; Jalayer, Javad; Bozorgnia, Yasaman
2013-11-21
Although using light-cured composites for bonding orthodontic brackets has become increasingly popular, curing light cannot penetrate the metallic bulk of brackets and polymerization of composites is limited to the edges. Limited access and poor direct sight may be a problem in the posterior teeth. Meanwhile, effectiveness of the trans-illumination technique is questionable due to increased bucco-lingual thickness of the posterior teeth. Light-emitting diode (LED) light-curing units cause less temperature rise and lower risk to the pulpal tissue. The purpose of this study was to evaluate the clinical effectiveness of trans-illumination technique in bonding metallic brackets to premolars, using different light intensities and curing times of an LED light-curing unit. Sixty premolars were randomly divided into six groups. Bonding of brackets was done with 40- and 80-s light curing from the buccal or lingual aspect with different intensities. Shear bond strengths of brackets were measured using a universal testing machine. Data were analyzed by one-way analysis of variance test and Duncan's post hoc test. The highest shear bond belonged to group 2 (high intensity, 40 s, buccal) and the lowest belonged to group 3 (low intensity, 40 s, lingual). Bond strength means in control groups were significantly higher than those in experimental groups. In all experimental groups except group 6 (80 s, high intensity, lingual), shear bond strength was below the clinically accepted values. In clinical limitations where light curing from the same side of the bracket is not possible, doubling the curing time and increasing the light intensity during trans-illumination are recommended for achieving acceptable bond strengths.
Lim, H J; Kim, G D; Jung, E Y; Seo, H W; Joo, S T; Jin, S K; Yang, H S
2014-08-01
This study was done to investigate the quality properties of beef jerky with soy sauce, red pepper paste, and soybean paste replacing salt. Sliced beef samples were cured in salt (control), soy sauce, red pepper paste, and soybean paste for 24 or 48 h and then dried at 70°C for 8 h. Treatments showed higher final moisture content and lower Na(+) concentration than the control after drying for 8 h. The lightness and shear force values were lower in all treatment samples than in the control during 48 h of curing time. In particular, lower lipid oxidation was found in the jerky cured with red pepper paste than in the control. Sensory evaluation showed that color, flavor, and tenderness of jerky samples were improved by replacing salt with soy sauce, red pepper paste and soybean paste, and higher likeability scores of the beef jerky were obtained among those treatments after 48 h of curing time.
Multi-state models for colon cancer recurrence and death with a cured fraction.
Conlon, A S C; Taylor, J M G; Sargent, D J
2014-05-10
In cancer clinical trials, patients often experience a recurrence of disease prior to the outcome of interest, overall survival. Additionally, for many cancers, there is a cured fraction of the population who will never experience a recurrence. There is often interest in how different covariates affect the probability of being cured of disease and the time to recurrence, time to death, and time to death after recurrence. We propose a multi-state Markov model with an incorporated cured fraction to jointly model recurrence and death in colon cancer. A Bayesian estimation strategy is used to obtain parameter estimates. The model can be used to assess how individual covariates affect the probability of being cured and each of the transition rates. Checks for the adequacy of the model fit and for the functional forms of covariates are explored. The methods are applied to data from 12 randomized trials in colon cancer, where we show common effects of specific covariates across the trials. Copyright © 2013 John Wiley & Sons, Ltd.
Curing efficacy of a new generation high-power LED lamp.
Yap, Adrian U J; Soh, M S
2005-01-01
This study investigated the curing efficacy of a new generation high-power LED lamp (Elipar Freelight 2 [N] 3M-ESPE). The effectiveness of composite cure with this new lamp was compared to conventional LED/halogen (Elipar Freelight [F], 3M-ESPE; Max [M], Dentsply-Caulk) and high-power halogen (Elipar Trilight [T], 3M-ESPE; Astralis 10 [A], Ivoclar Vivadent) lamps. Standard continuous (NS, FS, TS; MS), turbo (AT) and exponential (NE, FE, TE) curing modes of the various lights were examined. Curing efficacy of the various lights and modes were determined by measuring the top and bottom surface hardness of 2-mm thick composite specimens (Z100, 3M-ESPE) using a digital microhardness tester (n=5; load=500 g; dwell time=15 seconds) one hour after light polymerization. The hardness ratio was computed by dividing HK (Knoops Hardness) of the bottom surface by HK of the top surface. The data was analyzed using one-way ANOVA/Scheffe's test and Independent Samples t-test at significance level 0.05. Results of the statistical analysis were as follows: HK top--E, FE, NE > NS and NE > AT, TS, FS; HK bottom--TE, NE > NS; Hardness ratio--NS > FE and FS, TS > NE. No significant difference in HK bottom and hardness ratio was observed between the two modes of Freelight 2 and Max. Freelight 2 cured composites as effectively as conventional LED/halogen and high-power halogen lamps, even with a 50% reduction in cure time. The exponential modes of Freelight 2, Freelight and Trilight appear to be more effective than their respective standard modes.
Creatine and creatinine evolution during the processing of dry-cured ham.
Mora, Leticia; Hernández-Cázares, Aleida S; Sentandreu, Miguel Angel; Toldrá, Fidel
2010-03-01
Dry-curing of ham involves many biochemical reactions that depend on the processing conditions. The aim of this study was to evaluate the effect of the dry-cured processing on the concentration of creatine, creatinine and the creatinine/creatine ratio. Dry-cured hams under study were salted using three different salt mixtures (100% NaCl; NaCl and KCl at 50% each; and 55% NaCl, 25% KCl, 15% CaCl(2) and 5% MgCl(2)) in order to observe its influence on creatinine formation but no significant differences were found between them at any time of processing. However, significant differences between different post-salting times (20, 50 and 80 days) and the ripened hams (7, 9 and 11 months of ripening) were observed. Results showed that creatine and creatinine remain stable once the ripening period is reached. These results were confirmed when analysing dry-cured ham samples submitted to extreme conditions of temperature and time (20, 30, 40 and 70 degrees C during 0, 20, 40 and 60 min) as well as commercial dry-cured hams with more than 12 months of processing. Copyright 2009 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Möginger, B.; Kehret, L.; Hausnerova, B.; Steinhaus, J.
2016-05-01
3D-Printing is an efficient method in the field of additive manufacturing. In order to optimize the properties of manufactured parts it is essential to adapt the curing behavior of the resin systems with respect to the requirements. Thus, effects of resin composition, e.g. due to different additives such as thickener and curing agents, on the curing behavior have to be known. As the resin transfers from a liquid to a solid glass the time dependent ion viscosity was measured using DEA with flat IDEX sensors. This allows for a sensitive measurement of resin changes as the ion viscosity changes two to four decades. The investigated resin systems are based on the monomers styrene and HEMA. To account for the effects of copolymerization in the calculation of the reaction kinetics it was assumed that the reaction can be considered as a homo-polymerization having a reaction order n≠1. Then the measured ion viscosity curves are fitted with the solution of the reactions kinetics - the time dependent degree of conversion (DC-function) - for times exceeding the initiation phase representing the primary curing. The measured ion viscosity curves can nicely be fitted with the DC-function and the determined fit parameters distinguish distinctly between the investigated resin compositions.
Moon, H-J; Lee, Y-K; Lim, B-S; Kim, C-W
2004-03-01
The purpose of this study was to evaluate the effect of the various light curing units (plasma arc, halogen and light-emitting diodes) and irradiation methods (one-step, two-step and pulse) using different light energy densities on the leachability of unreacted monomers (Bis-GMA and UDMA) and the surface hardness of a composite resin (Z250, 3M). Leachability of the specimens immersed for 7 days in ethanol was analysed by HPLC. Vicker's hardness number (VHN) was measured immediately after curing (IC) and after immersion in ethanol for 7 days. Various irradiation methods with three curing units resulted in differences in the amount of leached monomers and VHN of IC when light energy density was lower than 17.0 J cm(-2) (P = 0.05). However, regardless of curing units and irradiation methods, these results were not different when the time or light energy density increased. When similar light energy density was irradiated (15.6-17.7 J cm(-2)), the efficiency of irradiation methods was different by the following order: one-step > or = two-step > pulse. These results suggest that the amount of leached monomers and VHN were influenced by forming polymer structure in activation and initiation stages of polymerization process with different light source energies and curing times.
Acoustic Monitoring of Adhesive Bond Curing in Wood Laminates.
NASA Astrophysics Data System (ADS)
Biernacki, Jacek Marek
Challenges in manufacturing of wood products, such as glulam, include difficulty in controlling bonding variables and assessing bond quality. This dissertation investigates an ultrasonic method as a means of monitoring of curing and assessing bond quality in wood laminates. The effect of curing on ultrasonic transmission was studied using specimens of clear Douglas-fir, 100 x 200 x 600 mm, with the adhesive bond in the center of the specimen. Monitoring was performed simultaneously at normal and angular (5 ^circ nominal) incidence to the bond plane. Acoustic measurements were supplemented with destructive cure monitoring, standard bond strength measurement, monitoring of bulk viscosity curing, gel time measurement, and microscopic (SEM) examination. Angular incidence gave greater sensitivity to bond quality and curing status than did normal incidence. Analysis of wave propagation showed that displacement for transmission at a small angle (on the order of 5^circ ) was nearly parallel to the bond, which seems to explain greater sensitivity of angular incidence. Experimental results showed that this method was effective in detection of curing phases, such as spread, penetration, and hardening, defective bonds, and the effect of clamping pressure. An "unloading effect", measured as a relative transmission reduction after the clamping load was released, was sensitive to defective bonds, including uncured (kissing), underspread, and uneven spread bonds. Thick bonds (0.5 and 1.0 mm) caused the greatest increase in transmission, since waves at start of curing were highly attenuated. In angular transmission, thick-bond curing curves showed a characteristic inflection, which may be used to identify thick bonds and measure the curing rate. The results of this dissertation could be utilized to develop commercial systems in glulam manufacturing, which could evaluate: (a) phase of and completion of curing (b) bond quality (c) optimum clamping pressure. Similar systems could also be developed to monitor lumber and panel products curing at high temperature, such as LVL (laminated veneer lumber), OSB (oriented strandboard) and particleboard.
Flury, Simon; Lussi, Adrian; Hickel, Reinhard; Ilie, Nicoleta
2014-04-01
The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.
Parametric study on the compressive strength geopolymer paving block
NASA Astrophysics Data System (ADS)
Aman; Awaluddin, A.; Ahmad, A.; Olivia, M.
2018-04-01
This paper reported about the investigated of sodium hidroxida concentration, effect of ratio liquid to solid (L/S), temperature and time on the compressive strength of geopolymer paving block using fly ash and fine aggregate as base material and combination of sodium hidroxida and sodium silicate as alkaline activator and the ratio of Na2SiO3/NaOH was 2 and fly ash to aggregate of 1: 3. The experiments were conducted with variation of the sodium hidroxida concentration of (10-16 M) liquid to solid (L/S) 0.1- 0.7 ratio, curing temperature 30-100 °C and curing time (7-28 day). The main evaluation techniques in this experimental were Compressive strength, X-ray diffraction (XRD),and Scaning Electron Microscope (SEM). The result showed that the compressive strength of Geopolymer Paving block has increased with an increasing of concentration, liquid to solid ratio, curing temperature and curing time.
Exploration Of `Click' Chemistry For Microelectronic Applications
NASA Astrophysics Data System (ADS)
Musa, Osama M.; Sridhar, Laxmisha M.
The ‘Click’ chemistry was explored for low temperature snap cure and for possible use as an adhesion promoter in electronic applications. Several azide and alkyne resins were synthesized and their curing potential was evaluated with a special emphasis on exploring Cu(I) catalyst effect. The preliminary curing study in the absence of catalysts showed a strong dependence of cure temperatures on the electronic nature of alkynes. The cure temperatures showed a tendency to increase with decreasing electronegativity of the substituent on alkynes. The capability of Cu(I) catalysts to accelerate the ‘Click’ chemistry was demonstrated for the first time in bulk phase. Using several Cu(I) catalysts, the cure temperatures could be lowered by as much as 40-100°C compared to the control, depending on the nature of catalyst and the catalyst loading. We discovered a novel synergistic effect between Cu(I) and silver filler in lowering the cure temperatures. Using this combination, lower cure temperatures could be obtained than using either alone. Among several resins screened, one resin system has shown promise for 80°C snap-cure in which the aforementioned synergistic effect is operative. Solution phase ‘Click’ chemistry was employed for the synthesis of a hybrid triazole-epoxy resin system. This system was found to cure without added amine curative. The triazole group here serves as a linker as well as an internal adhesion promoter. To address the incompatibility and volatility issues, which arose during evaluation, a controlled oligomerization method has been developed using controlled heating of azides and alkynes in solution phase.
Screening and cervical cancer cure: population based cohort study
Andersson, Therese M-L; Lambert, Paul C; Kemetli, Levent; Silfverdal, Lena; Strander, Björn; Ryd, Walter; Dillner, Joakim; Törnberg, Sven; Sparén, Pär
2012-01-01
Objective To determine whether detection of invasive cervical cancer by screening results in better prognosis or merely increases the lead time until death. Design Nationwide population based cohort study. Setting Sweden. Participants All 1230 women with cervical cancer diagnosed during 1999-2001 in Sweden prospectively followed up for an average of 8.5 years. Main outcome measures Cure proportions and five year relative survival ratios, stratified by screening history, mode of detection, age, histopathological type, and FIGO (International Federation of Gynecology and Obstetrics) stage. Results In the screening ages, the cure proportion for women with screen detected invasive cancer was 92% (95% confidence interval 75% to 98%) and for symptomatic women was 66% (62% to 70%), a statistically significant difference in cure of 26% (16% to 36%). Among symptomatic women, the cure proportion was significantly higher for those who had been screened according to recommendations (interval cancers) than among those overdue for screening: difference in cure 14% (95% confidence interval 6% to 23%). Cure proportions were similar for all histopathological types except small cell carcinomas and were closely related to FIGO stage. A significantly higher cure proportion for screen detected cancers remained after adjustment for stage at diagnosis (difference 15%, 7% to 22%). Conclusions Screening is associated with improved cure of cervical cancer. Confounding cannot be ruled out, but the effect was not attributable to lead time bias and was larger than what is reflected by down-staging. Evaluations of screening programmes should consider the assessment of cure proportions. PMID:22381677
Screening and cervical cancer cure: population based cohort study.
Andrae, Bengt; Andersson, Therese M-L; Lambert, Paul C; Kemetli, Levent; Silfverdal, Lena; Strander, Björn; Ryd, Walter; Dillner, Joakim; Törnberg, Sven; Sparén, Pär
2012-03-01
To determine whether detection of invasive cervical cancer by screening results in better prognosis or merely increases the lead time until death. Nationwide population based cohort study. Sweden. All 1230 women with cervical cancer diagnosed during 1999-2001 in Sweden prospectively followed up for an average of 8.5 years. Cure proportions and five year relative survival ratios, stratified by screening history, mode of detection, age, histopathological type, and FIGO (International Federation of Gynecology and Obstetrics) stage. In the screening ages, the cure proportion for women with screen detected invasive cancer was 92% (95% confidence interval 75% to 98%) and for symptomatic women was 66% (62% to 70%), a statistically significant difference in cure of 26% (16% to 36%). Among symptomatic women, the cure proportion was significantly higher for those who had been screened according to recommendations (interval cancers) than among those overdue for screening: difference in cure 14% (95% confidence interval 6% to 23%). Cure proportions were similar for all histopathological types except small cell carcinomas and were closely related to FIGO stage. A significantly higher cure proportion for screen detected cancers remained after adjustment for stage at diagnosis (difference 15%, 7% to 22%). Screening is associated with improved cure of cervical cancer. Confounding cannot be ruled out, but the effect was not attributable to lead time bias and was larger than what is reflected by down-staging. Evaluations of screening programmes should consider the assessment of cure proportions.
High performance printed oxide field-effect transistors processed using photonic curing.
Garlapati, Suresh Kumar; Marques, Gabriel Cadilha; Gebauer, Julia Susanne; Dehm, Simone; Bruns, Michael; Winterer, Markus; Tahoori, Mehdi Baradaran; Aghassi-Hagmann, Jasmin; Hahn, Horst; Dasgupta, Subho
2018-06-08
Oxide semiconductors are highly promising candidates for the most awaited, next-generation electronics, namely, printed electronics. As a fabrication route for the solution-processed/printed oxide semiconductors, photonic curing is becoming increasingly popular, as compared to the conventional thermal curing method; the former offers numerous advantages over the latter, such as low process temperatures and short exposure time and thereby, high throughput compatibility. Here, using dissimilar photonic curing concepts (UV-visible light and UV-laser), we demonstrate facile fabrication of high performance In 2 O 3 field-effect transistors (FETs). Beside the processing related issues (temperature, time etc.), the other known limitation of oxide electronics is the lack of high performance p-type semiconductors, which can be bypassed using unipolar logics from high mobility n-type semiconductors alone. Interestingly, here we have found that our chosen distinct photonic curing methods can offer a large variation in threshold voltage, when they are fabricated from the same precursor ink. Consequently, both depletion and enhancement-mode devices have been achieved which can be used as the pull-up and pull-down transistors in unipolar inverters. The present device fabrication recipe demonstrates fast processing of low operation voltage, high performance FETs with large threshold voltage tunability.
High performance printed oxide field-effect transistors processed using photonic curing
NASA Astrophysics Data System (ADS)
Garlapati, Suresh Kumar; Cadilha Marques, Gabriel; Gebauer, Julia Susanne; Dehm, Simone; Bruns, Michael; Winterer, Markus; Baradaran Tahoori, Mehdi; Aghassi-Hagmann, Jasmin; Hahn, Horst; Dasgupta, Subho
2018-06-01
Oxide semiconductors are highly promising candidates for the most awaited, next-generation electronics, namely, printed electronics. As a fabrication route for the solution-processed/printed oxide semiconductors, photonic curing is becoming increasingly popular, as compared to the conventional thermal curing method; the former offers numerous advantages over the latter, such as low process temperatures and short exposure time and thereby, high throughput compatibility. Here, using dissimilar photonic curing concepts (UV–visible light and UV-laser), we demonstrate facile fabrication of high performance In2O3 field-effect transistors (FETs). Beside the processing related issues (temperature, time etc.), the other known limitation of oxide electronics is the lack of high performance p-type semiconductors, which can be bypassed using unipolar logics from high mobility n-type semiconductors alone. Interestingly, here we have found that our chosen distinct photonic curing methods can offer a large variation in threshold voltage, when they are fabricated from the same precursor ink. Consequently, both depletion and enhancement-mode devices have been achieved which can be used as the pull-up and pull-down transistors in unipolar inverters. The present device fabrication recipe demonstrates fast processing of low operation voltage, high performance FETs with large threshold voltage tunability.
The Effect on Final Bond Strength of Bracket Manipulation Subsequent To Initial Positioning
NASA Astrophysics Data System (ADS)
Beebe, David A.
The shear bond strength of light activated orthodontic adhesives varies according to the composition of the material, placement protocol, and time prior to light curing. Manipulating brackets after their initial placement on a tooth can disrupt the adhesive's polymerization and compromise final bond strength. No previous research has investigated how a specific degree of manipulation, and the amount of time elapsed prior to curing, under specific lighting conditions, affects the orthodontic adhesives shear bond strength. Victory SeriesRTM, MBT prescription, premolar (3M Unitek, Monrovia, CA) orthodontic brackets were bonded using three different adhesives to sixty (60) bicuspids and varying the time after bracket manipulation before curing. The shear bond strength was calculated for each specimen. The brackets were debonded and the same teeth were rebonded with new, identical brackets, using the same protocol and under the same conditions. The results showed a statistically significant difference between the shear bond strength of Transbond XT and Grengloo, with Transbond XT having the highest strength. There was also a statistically significance difference in bond strength between the group cured 30 seconds after manipulation and the groups manipulated at different intervals prior to curing, with the 30 second group having the highest bond strength. This study confirms that various orthodontic adhesives have different bond strengths depending on manipulation and varying times prior to curing each adhesive.
Investigation of Coatings Which Prevent Molten Aluminum/Water Explosions
NASA Astrophysics Data System (ADS)
León, D. D.; Richter, R. T.; Levendusky, T. L.
The Aluminum Association contracted Alcoa in 1995 to identify and test new protective coatings for casting pits as a replacement for Porter International's 7001 (Tarset Standard). Three new coatings have been identified through a series of selection criteria including: 1) A standardized splash test used to evaluate personal protective clothing, 2) An industry-standard molten metal explosion test, 3) A multiple-exposure test to measure durability, and 4) An external shock impact test. The results of this program will be reviewed. This study only tested protective coatings at the "in-service cure time", as defined by the manufacturer. These curing times can be excessive for a production casting facility. The Aluminum Association has contracted Alcoa in a second program to investigate the effect of reduced cure times on adhesion and their effectiveness in preventing molten metal/water explosions. A status update of this new two year program is provided.
Jackson, Armitra L; Kulchaiyawat, Charlwit; Sullivan, Gary A; Sebranek, Joseph G; Dickson, James S
2011-03-01
A major concern for processed meats marketed as natural/organic is that they do not contain nitrite in concentrations known to be most effective for inhibiting foodborne pathogens. Supplemental treatments to increase the level and consistency of antimicrobial protection in these products may be important to provide consumers with the degree of safety that they have come to expect from conventionally cured meats. Therefore, the objective of this study was to identify and test ingredients that might improve processed meat product safety without altering their natural/organic status. Eight treatments of hams and frankfurters were prepared: (A) uncured control (typical ingredients except nitrite and nitrate); (B) conventionally cured control (erythorbate, nitrite, and a lactate-diacetate blend); (C) natural nitrate cure (including starter culture containing Staphylococcus carnosus); (D) natural nitrate cure (culture and natural antimicrobial A containing a vinegar, lemon, and cherry powder blend); (E) natural nitrate cure (culture and antimicrobial B containing a cultured sugar and vinegar blend); (F) natural nitrite cure without additional antimicrobials; (G) natural nitrite cure with natural antimicrobial A; and (H) natural nitrite cure with antimicrobial B. For the hams, treatments C, D, E, and H impacted growth of Clostridium perfringens to the same extent (P < 0.05) as the conventionally cured control (approximately 2 log less growth over time than uncured control). For frankfurters, treatments D, G, and H had an effect (approximately 1 log) on growth equivalent to that of the conventionally cured control (P < 0.05). These results suggest that natural/organic cured meats have more potential for pathogen growth than conventionally cured products, but supplemental natural ingredients offer safety improvement.
Mousavinasab, Sayed Mostafa; Meyers, Ian
2011-07-01
To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was used to prepare ten samples with LED light source cured for forty seconds and ten samples prepared using high power QTH light unit, cured for four or six seconds recommended exposure time. Hardness, depth of cure (DOC) and thermal rise during exposure time by these light sources were measured. The data submitted to analysis of variance (ANOVA), Tukey's and student's t tests at 5% significance level. Significant differences were found in hardness, DOC of samples cured by above mentioned light sources and also in thermal rises during exposure time. The curing performance of the tested QTH was not as well as the LED light. TPB light source produced the maximum hardness (81.25, 73.29, 65.49,55.83 and 24.53 for 0 mm, 1 mm, 2 mm, 3 mm and 4 mm intervals) and DOC (2.64 mm) values with forty seconds irradiation time and the high power (QTH) the least hardness (73.27, 61.51 and 31.59 for 0 mm, 1 mm and 2 mm, respectively) and DOC (2 mm) values with four seconds irradiation time. Thermal rises during 4 s and 6 s curing time using high power QTH and tested LED were 1.88°C, 3°C and 1.87°C, respectively. The used high power LED light produced greater hardness and depth of cure during forty seconds exposure time compared to high power QTH light with four or six seconds curing time. Thermal rise during 6 s curing time with QTH was greater compared to thermal changes occurred during 40 s curing time with tested LED light source. There was no difference seen in thermal changes caused by LED light with 40 s and QTH light with 4 s exposure time.
Survival analysis of patients with esophageal cancer using parametric cure model.
Rasouli, Mahboube; Ghadimi, Mahmood Reza; Mahmoodi, Mahmood; Mohammad, Kazem; Zeraati, Hojjat; Hosseini, Mostafa
2011-01-01
Esophageal cancer is a major cause of mortality and morbidity in the Caspian littoral north-eastern part of Iran. The aim of this study was to calculate cure function as well as to identify the factors that are related to this function among patients with esophageal cancer in this geographical area. Three hundred fifty nine cases of esophageal cancer registered in the Babol cancer registry during the period of 1990 to 1991 (inclusive) were followed up for 15 years up to 2006. Parametric cure model was used to calculate cure fraction and investigate the factors responsible for probability of cure among patients. Sample of subjects encompassed 62.7% men and 37.3% women, with mean ages of diagnosis was 60.0 and 55.3 years, respectively. The median survival time reached about 9 months and estimated survival rates in 1, 3, and 5 years following diagnosis were 23%, 15% and 13%, respectively. Results show the family history affects the cured fraction independently of its effect on early outcome and has a significant effect on the probability of uncured. The average cure fraction was estimated to be 0.10. As the proportionality assumption of Cox model does not meet in certain circumstances, a parametric cure model can provide a better fit and a better description of survival related outcome.
Shear bond strength of orthodontic color-change adhesives with different light-curing times
Bayani, Shahin; Ghassemi, Amirreza; Manafi, Safa; Delavarian, Mohadeseh
2015-01-01
Background: The purpose of this study was to evaluate the effect of light-curing time on the shear bond strength (SBS) of two orthodontic color-change adhesives (CCAs). Materials and Methods: A total of 72 extracted premolars were randomly assigned into 6 groups of 12 teeth each. Subsequent to primer application, a metal bracket was bonded to the buccal surface using an orthodontic adhesive. Two CCAs (Greengloo and Transbond Plus) were tested and one conventional light-cured adhesive (Resilience) served as control. For each adhesive, the specimens were light-cured for two different times of 20 and 40 s. All the specimens underwent mechanical testing using a universal testing machine to measure the SBS. Adhesive remnant index (ARI) was used to assess the remnant adhesive material on the tooth surface. All statistical analyses were performed using SPSS software. The significance level for all statistical tests was set at P ≤ 0.05. Results: The SBSs of the tested groups were in the range of 14.05-31.25 MPa. Greengloo adhesive showed the highest SBS values when light-cured for 40 s, and Transbond Plus adhesive showed the lowest values when light-cured for 20 s. ARI scores of Transbond Plus adhesive were significantly higher than those of controls, while other differences in ARI values were not significant. Conclusion: Within the limitations of his study, decreasing the light-curing time from 40 to 20 s decreased the SBS of the tested adhesives; however, this decline in SBS was statistically significant only in Transbond Plus adhesive PMID:26005468
Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness.
Reges, Rogério Vieira; Costa, Ana Rosa; Correr, Américo Bortolazzo; Piva, Evandro; Puppin-Rontani, Regina Maria; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço
2009-01-01
The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm(2), respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukey's test (alpha=0.05). The QTH LCU provided significantly higher (p<0.05) KHN values than the LED LCU. When the post-cure times were compared for the same shade, QTH and LED at 24 h provided significantly higher (p<0.05) KHN values than at 15 min. It may be concluded that the Knoop hardness was generally dependent on the LCU and post-cure time. The opaque shade of the resin cement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.
Outgassing of Out-of-Autoclave Composite Primary Structures for Small Satellites
NASA Astrophysics Data System (ADS)
Komus, Alastair
Out-of-autoclave vacuum-bagged-only (VBO) processing is capable of producing lower cost composite primary structures for small satellites than autoclave processing. However, the outgassing performance of VBO structures in a vacuum environment has not been examined. Panels were manufactured from CYCOM 5320-1 and TC275-1 carbon fiber/epoxy prepreg using VBO processing. The humidity level, pre-cure dwell time, and cure cycle parameters were varied during manufacturing. The degree of cure and glass transition temperature were shown to increase with increasing oven temperature. Processing humidity levels and the length of pre-cure dwell times had no discernable effect on the total mass loss (TML) and collected volatile condensable material (CVCM) that were outgassed under vacuum. Instead the TML was controlled by moisture saturation after manufacturing. Fourier transform infrared spectroscopy showed that epoxy oligomers were the primary CVCM. The study showed the VBO laminates had outgassing values that were comparable to the autoclave-cured laminates.
Pharmacodynamic study on insomnia-curing effects of Shuangxia Decoction in Drosophila melanogaster.
Zhang, Zhi-Qian; Degejin; Geng, Di; Zhang, Qi; Tian, Yan; Xi, Yuan; Wang, Wen-Qi; Tang, Hua-Qi; Xu, Bing; Lin, Hong-Ying; Sun, Yi-Kun
2016-09-01
The present study aimed to establish a pharmacodynamic method using the pySolo software to explore the influence of freeze-dried powders of Shuangxia Decoction (SXD) on the sleep of normal Drosophila melanogaster and the Drosophila melanogaster whose sleep was divested by light. The dose-effect and the time-effect relationships of SXD on sleep were examined. The effect-onset concentration of SXD was 0.25%, the plateau appeared at the concentration of 2.5% and the total sleep time showed a downtrend when the concentration was greater than 2.5%. The sleep time was the longest on the fourth day after SXD was given. The fruit fly sleep deprivation model was repeated by light stimulation at night. The middle dosage group (2.5%) had the best insomnia-curing effect. In conclusion, using the pySolo software, an approach for the pharmacodynamics study was established with Drosophila melanogaster as a model organism to determine the insomnia-curing effects of the traditional Chinese medicine (TCM). Our results demonstrated the reliability of this method. The freeze-dried powders of SXD could effectively improve the sleep quality of Drosophila melanogaster. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Rodrigues, Jose Augusto; Tenorio, Ilana Pais; Mello, Ginger Baranhuk Rabello de; Reis, André Figueiredo; Shen, Chiayi; Roulet, Jean-François
2017-08-21
The effect of restoration depth on the curing time of a conventional and two bulk-fill composite resins by measuring microhardness and the respective radiosity of the bottom surface of the specimen was investigated. 1-, 3- and 5-mm thick washers were filled with Surefil SDR Flow-U (SDR), Tetric EvoCeram Bulk Fill-IVA (TEC) or Esthet-X HD-B1 (EHD), and cured with Bluephase® G2 for 40s. Additional 1-mm washers were filled with SDR, TEC or EHD, placed above the light sensor of MARC®, stacked with pre-cured 1-, 3- or 5-mm washer of respective material, and cured for 2.5~60s to mimic 2-, 4- and 6-mm thick composite curing. The sensor measured the radiosity (EB) at the bottom of specimen stacks. Vickers hardness (VH) was measured immediately at 5 locations with triplicate specimens. Nonlinear regression of VH vs EB by VH=α[1-exp(-EB/β)] with all thickness shows that the values of α, maximum hardness, are 21.6±1.0 kg/mm2 for SDR, 38.3±0.6 kg/mm2 for TEC and 45.3±2.6 kg/mm2 for EHD, and the values of β, rate parameter, are 0.40±0.06 J/cm2 for SDR, 0.77±0.04 J/cm2 for TEC and 0.58±0.09 J/cm2 for EHD. The radiosity of the bottom surface was calculated when the bottom surface of each material attained 80% of α of each material. The curing times for each material are in agreement with manufacturer recommendation for thickness. It is possible to estimate time needed to cure composite resin of known depth adequately by the radiosity and microhardness of the bottom surface.
NASA Astrophysics Data System (ADS)
Wangkheeree, W.; Meekum, U.
2016-03-01
The effect of IPDA, DDS, BPA and DICY, as main ingredient of TETA based hardener were examined. The 2k design of experiment(DOE) with k=3 were preliminary explored. The designed parameters A(IPDA), B(DDS) and C(BPA) were assigned as low(-) and high(+) levels, respectively. The Design Expert™ was hired as the analyzing tool at α=0.05. The mixed epoxy resin was based on the commercial one. The designed responds including tcure, t50, impact strengths, flexural properties and HDT were measured, respectively. Regarding to ANOVA conclusion, it was found that, there were no significant effects on the assigned parameters on the interested responds, except for the HDT where BPA(C) was negative effect was found. The lower in the crosslink density of cured epoxy, inferior in HDT, the higher in BPA addition was hypothesized. It was found that impact strength of cured epoxy derived from all formula were unacceptable low and tcure and t50, were too short. Thus, the further investigation by adding DICY into hardener was explored. The results showed that no significant change by mechanical means of cured epoxy by resolving 5-30 phr of DICY into the hardener. However, it was observed that the DICY added formula showed the obvious long cure times and behave as prepreg formula. The room temperature cured epoxy was incompletely crosslinked. The degrees of linear chain fragment were evidence, by weight, when higher DICY loading was engaged. Complete crosslink was achieved at 150°C post curing. The hardener comprised of TETA/aliphatic Epoxy(RD108) adduct was studied for enhancing the toughness of epoxy resin. It was observed that longer cure time at 150°C but lower toughness was experienced, on both prepreg and engineered wood made from the resins, at high TETA/RD108 ratio. Incomplete cure was explained for the mechanical inferior at high RD108 loading.
Mainardi, Maria do Carmo A J; Giorgi, Maria Cecília C; Lima, Débora A N L; Marchi, Giselle M; Ambrosano, Gláucia M; Paulillo, Luiz A M S; Aguiar, Flávio H B
2015-02-01
In the present study, we evaluated the influence of the photo-curing delay time and energy density on the degree of conversion and the Knoop microhardness of a resin cement. Seventy-eight samples were assigned to 13 groups (n = 6), one of which received no light curing (control). The samples were made of a dual-cured resin cement (RelyX ARC) with the aid of a Teflon matrix, submitted to one of the following energy densities (J/cm²): 7, 14, 20, and 28. Delay times were immediate (0), 1 min, or 2 min. After 24 h, the degree of conversion and microhardness were measured at three segments: cervical, medium, and apical. Data were submitted to three-way anova and Tukey's and Dunnett's tests, the latest of which was used to compare the control to the experimental groups. No interaction was observed between delay time and energy density regarding the degree of conversion. The cervical segment showed the highest values, while the apical showed the lowest. Microhardness values concerning the cervical segment in all groups were statistically different from that obtained for the control. A high-irradiance light-curing unit allows for a reduced irradiation exposure time with a short delay time, aimed at tooth restorations using a dual-cured resin cement. © 2014 Wiley Publishing Asia Pty Ltd.
25 CFR 162.592 - What will BIA do if a lessee does not cure a violation of a WSR lease on time?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false What will BIA do if a lessee does not cure a violation of a WSR lease on time? 162.592 Section 162.592 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER LEASES AND PERMITS Wind and Solar Resource Leases Wsr Lease Effectiveness...
25 CFR 162.592 - What will BIA do if a lessee does not cure a violation of a WSR lease on time?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false What will BIA do if a lessee does not cure a violation of a WSR lease on time? 162.592 Section 162.592 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER LEASES AND PERMITS Wind and Solar Resource Leases Wsr Lease Effectiveness...
Investigation of test methods, material properties, and processes for solar cell encapsulants
NASA Technical Reports Server (NTRS)
Willis, P. B.
1982-01-01
Technical investigations concerned the development of advanced cure chemistries for lamination type pottants; the continued evaluation of soil resistant surface treatments, and the results of an accelerated aging test program for the comparison of material stabilities. New compounds were evaluated for efficiency in curing both ethylene/vinyl acetate and ethylene/methyl acrylate pottants intended for vacuum bag lamination of solar cells. One compound in particular, designated Lupersol - TBEC (Lucidol Division of Pennwalt Corp.) was found to be unusually effective in promoting the rapid cure of both these materials. Formulation of these resins with TBEC resulted in compositions of very high gel content, lower temperatures of activation, and much lower cure times, even in the ethylene/methyl acrylate polymer that is more difficult to cure. It is expected that TBEC modified pottant formulations may permit the lamination/encapsulation step to be operated at lower temperatures, higher speed, higher throughput and a much wider tolerance for intentional or accidental variations in the cure schedule. An experimental program continued to determine the effectiveness of soil resistant coatings.
Contributions on the Study of the Compressive Strength of the Light-Cured Composite Resins
Manolea, H.; Degeratu, Sonia; Deva, V.; Coles, Evantia; Draghici, Emma
2009-01-01
The mechanical properties of the light-cured composite resins are related to the material composition, but also vary according to the light-source characteristics used for polymerization. In this study we followed the compressive strength variation for a light-cured composite resin according to the time of exposure to the curing light. With that end in view,18 test pieces were made from a light-cured hybrid composite material (Filtek Z250). The test pieces where then submitted to a compressive force by a mechanical properties universal testing machine. Our results didn’t show an increase of the compressive strength according to the light-curing time increasing, than only in the light-curing time limit indicated by the manufacturer. A longer light-curing time may induce a shrinkage polymerization growth with the formation of internal tensions inside the material. The composite materials light-curing in short layers as long as there is indicated by the manufacturer seems to be a safer method to make the best from a resin qualities, then an exaggerated increase of the light-curing time. The light-curing is indicated to be done in the direction of the compressive forces. To confirm this supposition other mechanical tests are also necessary PMID:24778814
Seong, Pil Nam; Park, Kuyng Mi; Kang, Sun Moon; Kang, Geun Ho; Cho, Soo Hyun; Park, Beom Young; Van Ba, Hoa
2014-01-01
The present study demonstrates the impact of specific breed on the characteristics of dry-cured ham. Eighty thighs from Korean native pig (KNP), crossbreed (Landrace×Yorkshire)♀×Duroc♂ (LYD), Berkshire (Ber), and Duroc (Du) pig breeds (n = 10 for each breed) were used for processing of dry-cured ham. The thighs were salted with 6% NaCl (w/w) and 100 ppm NaNO2, and total processing time was 413 days. The effects of breed on the physicochemical composition, texture, color and sensory characteristics were assessed on the biceps femoris muscle of the hams. The results revealed that the highest weight loss was found in the dry-cured ham of LYD breed and the lowest weight loss was found in Ber dry-cured ham. The KNP dry-cured ham contain higher intramuscular fat level than other breed hams (p<0.05). It was observed that the dry-cured ham made from KNP breed had the lowest water activity value and highest salt content, while the LYD dry-cure ham had higher total volatile basic nitrogen content than the Ber and Du hams (p<0.05). Zinc, iron and total monounsaturated fatty acids levels were higher in KNP ham while polyunsaturated fatty acids levels were higher in Du ham when compared to other breed hams (p<0.05). Additionally, the KNP dry-cured ham possessed higher Commission International de l’Eclairage (CIE) a* value, while the Du dry-cured ham had higher L*, CIE b* and hue angle values (p<0.05). Furthermore, breed significantly affected the sensory attributes of dry-cured hams with higher scores for color, aroma and taste found in KNP dry-cured ham as compared to other breed hams (p<0.05). The overall outcome of the study is that the breed has a potential effect on the specific chemical composition, texture, color and sensorial properties of dry-cured hams. These data could be useful for meat processors to select the suitable breeds for economical manufacturing of high quality dry-cured hams. PMID:25083111
Seong, Pil Nam; Park, Kuyng Mi; Kang, Sun Moon; Kang, Geun Ho; Cho, Soo Hyun; Park, Beom Young; Van Ba, Hoa
2014-08-01
The present study demonstrates the impact of specific breed on the characteristics of dry-cured ham. Eighty thighs from Korean native pig (KNP), crossbreed (Landrace×Yorkshire)♀×Duroc♂ (LYD), Berkshire (Ber), and Duroc (Du) pig breeds (n = 10 for each breed) were used for processing of dry-cured ham. The thighs were salted with 6% NaCl (w/w) and 100 ppm NaNO2, and total processing time was 413 days. The effects of breed on the physicochemical composition, texture, color and sensory characteristics were assessed on the biceps femoris muscle of the hams. The results revealed that the highest weight loss was found in the dry-cured ham of LYD breed and the lowest weight loss was found in Ber dry-cured ham. The KNP dry-cured ham contain higher intramuscular fat level than other breed hams (p<0.05). It was observed that the dry-cured ham made from KNP breed had the lowest water activity value and highest salt content, while the LYD dry-cure ham had higher total volatile basic nitrogen content than the Ber and Du hams (p<0.05). Zinc, iron and total monounsaturated fatty acids levels were higher in KNP ham while polyunsaturated fatty acids levels were higher in Du ham when compared to other breed hams (p<0.05). Additionally, the KNP dry-cured ham possessed higher Commission International de l'Eclairage (CIE) a* value, while the Du dry-cured ham had higher L*, CIE b* and hue angle values (p<0.05). Furthermore, breed significantly affected the sensory attributes of dry-cured hams with higher scores for color, aroma and taste found in KNP dry-cured ham as compared to other breed hams (p<0.05). The overall outcome of the study is that the breed has a potential effect on the specific chemical composition, texture, color and sensorial properties of dry-cured hams. These data could be useful for meat processors to select the suitable breeds for economical manufacturing of high quality dry-cured hams.
The first narrow-band XeCl-excilamp application for complex psoriasis curing
NASA Astrophysics Data System (ADS)
Dmitruck, Vadim S.; Sosnin, Edward A.; Obgol'tz, Irina A.
2006-05-01
Clinical efficiency estimation of XeCl-excilamp application for psoriasis curing in comparison with other methods of phototherapy for has been carried out for the first time. Curing psoriasis by XeCl-excilamp assistance is shown to be an effective and present-date method. Such a phototherapy advantages suggested are the good tolerance, and absence of intact skin irradiation. The use of chemicals is no longer relevant, and the total doze of irradiation happens to be rather low.
Prevent and cure disuse bone loss
NASA Technical Reports Server (NTRS)
Jee, Webster S. S.
1994-01-01
Anabolic agents like parathyroid hormone and postagladin E-like substances were studied in dogs and rats to determine their effectiveness in the prevention and cure of bone loss due to immobilization. It was determined that postagladin E2 administration prevented immobilization while at the same time it added extra bone in a dose responsive manner. Although bone mass returns, poor trabecular architecture remains after normal ambulation recovery from immobilization. Disuse related bone loss and poor trabecular architecture were cured by post-immobilization postagladin E2 treatment.
NASA Astrophysics Data System (ADS)
Guner, D.; Ozturk, H.
2016-08-01
The effects of curing time on tensile elastic material properties of thin spray-on liners (TSLs) were investigated in this study. Two different TSL products supplied by two manufacturers were tested comparatively. The "dogbone" tensile test samples that were prepared in laboratory conditions with different curing times (1, 7, 14, 21, and 28 days) were tested based on ASTM standards. It was concluded that longer curing times improves the tensile strength and the Young's Modulus of the TSLs but decreases their elongation at break. Moreover, as an additional conclusion of the testing procedure, it was observed that during the tensile tests, the common malpractice of measuring sample displacement from the grips of the loading machine with a linear variable displacement transducer versus the sample's gauge length had a major impact on modulus and deformation determination of TSLs. To our knowledge, true stress-strain curves were generated for the first time in TSL literature within this study. Numerical analyses of the laboratory tests were also conducted using Particle Flow Code in 2 Dimensions (PFC2D) in an attempt to guide TSL researchers throughout the rigorous PFC simulation process to model support behaviour of TSLs. A scaling coefficient between macro- and micro-properties of PFC was calculated which will help future TSL PFC modellers mimic their TSL behaviours for various tensile loading support scenarios.
Cure models for the analysis of time-to-event data in cancer studies.
Jia, Xiaoyu; Sima, Camelia S; Brennan, Murray F; Panageas, Katherine S
2013-11-01
In settings when it is biologically plausible that some patients are cured after definitive treatment, cure models present an alternative to conventional survival analysis. Cure models can inform on the group of patients cured, by estimating the probability of cure, and identifying factors that influence it; while simultaneously focusing on time to recurrence and associated factors for the remaining patients. © 2013 Wiley Periodicals, Inc.
Heat transfer properties and thermal cure of glass-ionomer dental cements.
Gavic, Lidia; Gorseta, Kristina; Glavina, Domagoj; Czarnecka, Beata; Nicholson, John W
2015-10-01
Under clinical conditions, conventional glass-ionomer dental cements can be cured by application of heat from dental cure lamps, which causes acceleration in the setting. In order for this to be successful, such heat must be able to spread sufficiently through the cement to enhance cure, but not transmit heat so effectively that the underlying dental pulp of the tooth is damaged. The current study was aimed at measuring heat transfer properties of modern restorative glass-ionomers to determine the extent to which they meet these twin requirements. Three commercial glass ionomer cements (Ionofil Molar, Ketac Molar and Equia™ Fill) were used in association with three different light emitting diode cure lamps designed for clinical use. In addition, for each cement, one set of specimens was allowed to cure without application of a lamp. Temperature changes were measured at three different depths (2, 3 and 4 mm) after cure times of 20, 40 and 60 s. The difference among the tested groups was evaluated by ANOVA (P < 0.05) and post hoc Newman-Keuls test. All brands of glass-ionomer showed a small inherent setting exotherm in the absence of heat irradiation, but much greater temperature increases when exposed to the cure lamp. However, temperature rises did not exceed 12.9 °C. Application of the cure lamp led to the establishment of a temperature gradient throughout each specimen. Differences were typically significant (P < 0.05) and did not reflect the nominal power of the lamps, because those lamps have variable cooling systems, and are designed to optimize light output, not heating effect. Because the thermal conductivity of glass-ionomers is low, temperature rises at 4 mm depths were much lower than at 2 mm. At no time did the temperature rise sufficiently to cause concern about potential damage to the pulp.
An infiltration/cure model for manufacture of fabric composites by the resin infusion process
NASA Technical Reports Server (NTRS)
Weideman, Mark H.; Loos, Alfred C.; Dexter, H. Benson; Hasko, Gregory H.
1992-01-01
A 1-D infiltration/cure model was developed to simulate fabrication of advanced textile composites by the resin film infusion process. The simulation model relates the applied temperature and pressure processing cycles, along with the experimentally measured compaction and permeability characteristics of the fabric preforms, to the temperature distribution, the resin degree of cure and viscosity, and the infiltration flow front position as a function of time. The model also predicts the final panel thickness, fiber volume fraction, and resin mass for full saturation as a function of compaction pressure. Composite panels were fabricated using the RTM (Resin Transfer Molding) film infusion technique from knitted, knitted/stitched, and 2-D woven carbon preforms and Hercules 3501-6 resin. Fabric composites were fabricated at different compaction pressures and temperature cycles to determine the effects of the processing on the properties. The composites were C-scanned and micrographed to determine the quality of each panel. Advanced cure cycles, developed from the RTM simulation model, were used to reduce the total cure cycle times by a factor of 3 and the total infiltration times by a factor of 2.
Mazzeti, Ana Lia; Diniz, Lívia de F; Gonçalves, Karolina R; Nascimento, Alvaro F S; Spósito, Pollyanna A F; Mosqueira, Vanessa C F; Machado-Coelho, George L L; Ribeiro, Isabela; Bahia, Maria T
2018-02-01
Benznidazole and nifurtimox-treatments regimens currently used in human are supported by very limited experimental data. This study was designed to evaluate the time and dose dependence for efficacy of the most important nitroheterocyclic drugs in use for Chagas disease. In order to evaluate time dependence, Y strain-infected mice received benznidazole for a total of 1, 3, 7, 10, 20, and 40 days. Treatment courses of 3-10-day were effective in clearing parasitaemia and suppressing mortality, but parasitological cure was not achieved. Extending the treatments to 20 or 40 days clearly improved benznidazole efficacy. The 20-day treatment induced cure in 57.1% of Y strain infections (partially drug resistant) but failed to cure Colombian strain infections (full drug resistant), while the 40-day treatment resulted in cure of 100% of Y and 50% of Colombian strain infected mice. The increased cure rates in T. cruzi infected animals that received nifurtimox for 40 days confirm the relationship between the length of treatment and efficacy. An improvement in efficacy was observed with increasing benznidazole doses; cure was verified in 28.6% (75 mg/kg), 57.1% (100 mg/kg) and 80% (300 mg/kg). Overall, these nonclinical study data provide evidence that the efficacy of benznidazole is dose and time dependent. These findings may be relevant for optimizing treatment of human Chagas disease. Copyright © 2018 Elsevier Inc. All rights reserved.
Effect of various light curing times on the elution of composite components.
Högg, Christof; Maier, Moritz; Dettinger-Maier, Katherina; He, Xiuli; Rothmund, Lena; Kehe, Kai; Hickel, Reinhard; Reichl, Franz-Xaver
2016-11-01
Polymerization of resin-based composites (RBCs) is incomplete. The aim of the present study was to determine whether a longer curing time than recommended by the manufacturer influences the amount of released composite components of RBCs. The composites Clearfil AP-X and els extra low shrinkage were polymerized for six different curing times: 4, 10, 20, 40, 100, and 200 s. Light curing time recommended by the manufacturer for both composites is 20 s. Subsequently, samples were eluted in methanol and water for 1, 3, and 7 days and analyzed by gas chromatography/mass spectrometry (GC/MS). For Clearfil AP-X ethylene glycol dimethacrylate (EGDMA), diethylene glycol dimethacrylate (DEGDMA), triethylene glycol dimethacrylate (TEGDMA), 2-hydroxy-4-methoxybenzophenone (HMBP), camphorquinone (CQ) and 2,6-di-tert-butyl-4-methylphenol (BHT) were detected in methanol. In the aqueous eluate, only TEGDMA was detected. In els extra low shrinkage, HMBP, BHT, and CQ were detected in methanol. Increasing the curing time compared to recommendation of the manufacturer reduces the release of most composite components. This could result in less exposure to human due to these substances. Methacrylates are classified as potential allergens. An increasing number of dentists and patients show allergic reaction to methacrylates. Therefore, a reduced elution of composite components is an advantage.
Electron Beam Cured Epoxy Resin Composites for High Temperature Applications
NASA Technical Reports Server (NTRS)
Janke, Christopher J.; Dorsey, George F.; Havens, Stephen J.; Lopata, Vincent J.; Meador, Michael A.
1997-01-01
Electron beam curing of Polymer Matrix Composites (PMC's) is a nonthermal, nonautoclave curing process that has been demonstrated to be a cost effective and advantageous alternative to conventional thermal curing. Advantages of electron beam curing include: reduced manufacturing costs; significantly reduced curing times; improvements in part quality and performance; reduced environmental and health concerns; and improvement in material handling. In 1994 a Cooperative Research and Development Agreement (CRADA), sponsored by the Department of Energy Defense Programs and 10 industrial partners, was established to advance the electron beam curing of PMC technology. Over the last several years a significant amount of effort within the CRADA has been devoted to the development and optimization of resin systems and PMCs that match the performance of thermal cured composites. This highly successful materials development effort has resulted in a board family of high performance, electron beam curable cationic epoxy resin systems possessing a wide range of excellent processing and property profiles. Hundreds of resin systems, both toughened and untoughened, offering unlimited formulation and processing flexibility have been developed and evaluated in the CRADA program.
RAMOS, Marcelo Barbosa; PEGORARO, Thiago Amadei; PEGORARO, Luiz Fernando; CARVALHO, Ricardo Marins
2012-01-01
Objectives To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray) used for cementing fiber-reinforced resin posts (Fibrekor® - Jeneric Pentron) under three different curing protocols and two water storage times. Material and methods Sixty 16mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: a) no light activation; b) light-activation immediately after seating the post, and; c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. Results Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. Conclusions The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent. PMID:23138743
Yu, Binbing
2012-01-01
Cancer survival is one of the most important measures to evaluate the effectiveness of treatment and early diagnosis. The ultimate goal of cancer research and patient care is the cure of cancer. As cancer treatments progress, cure becomes a reality for many cancers if patients are diagnosed early and get effective treatment. If a cure does exist for a certain type of cancer, it is useful to estimate the time of cure. For cancers that impose excess risk of mortality, it is informative to understand the difference in survival between cancer patients and the general cancer-free population. In population-based cancer survival studies, relative survival is the standard measure of excess mortality due to cancer. Cure is achieved when the survival of cancer patients is equivalent to that of the general population. This definition of cure is usually called the statistical cure, which is an important measure of burden due to cancer. In this paper, a minimum version of the log-rank test is proposed to test the equivalence of cancer patients' survival using the relative survival data. Performance of the proposed test is evaluated by simulation. Relative survival data from population-based cancer registries in SEER Program are used to examine patients' survival after diagnosis for various major cancer sites. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Venditti, T; D'Hallewin, G; Dore, A; Molinu, M G
2011-01-01
The restricted number of postharvest fungicides used in packing houses is leading to the selection of resistant strains of Penicillium digitatum (citrus green mould), one of the most common and serious pathogens during storage and marketing of lemons. Furthermore a growing concern for human health and a greater awareness for environmental conservation have multiplied the studies on new ecological technologies. Among the alternatives to synthetic postharvest fungicides, the use of acetic acid (classified as GRAS) together with a physical method such as curing, have led to encouraging results. In the present study is reported the combined use of curing, performed at reduced times compared to those reported to be effective, followed by acetic acid (AAC) treatments. Lemons of the variety "Limone di Massa" artificially inoculated with P. digitatum at a concentration of 10(4) spores/mL were cured for 0, 3, 6, 12 and 24 hours and then treated with three different concentrations of AAC (25, 50 and 75 microL/L) for 15 min. Fruit was then stored at 20 degrees C and 80% relative humidity (RH) for 9 days, when the number of decayed fruits was monitored. The same combined treatments were also carried out on naturally infected lemons, stored for 6 or 8 weeks at 5 degrees C and 90% RH. After 9 days of storage the lowest percentage of infected wounds, in artificially inoculated fruit, was 0% after 6 hours of curing followed by AAC fumigation performed at 50 microL/L, while lemons untreated or cured for three hours showed the worst results with 71.4 and 61.9% of rotted fruit respectively. In naturally infected lemons the best results were achieved with curing performed for 24 hours followed by AAC fumigation at 50 microL/L. In these cases the combined treatment reduced decay by the 91.0 and 66.5% after 6 or 8 weeks of storage respectively, if compared to untreated fruit. The weight loss was not affected by any of the treatments. These results show that a good control of green mould during storage could be achieved, on lemon fruit, by combining a reduced curing time of 24 hours to the effect of AAC. The best results were obtained after 6 week of storage even if a satisfactory control was observed after 8 weeks of storage.
Fitting Cure Rate Model to Breast Cancer Data of Cancer Research Center.
Baghestani, Ahmad Reza; Zayeri, Farid; Akbari, Mohammad Esmaeil; Shojaee, Leyla; Khadembashi, Naghmeh; Shahmirzalou, Parviz
2015-01-01
The Cox PH model is one of the most significant statistical models in studying survival of patients. But, in the case of patients with long-term survival, it may not be the most appropriate. In such cases, a cure rate model seems more suitable. The purpose of this study was to determine clinical factors associated with cure rate of patients with breast cancer. In order to find factors affecting cure rate (response), a non-mixed cure rate model with negative binomial distribution for latent variable was used. Variables selected were recurrence cancer, status for HER2, estrogen receptor (ER) and progesterone receptor (PR), size of tumor, grade of cancer, stage of cancer, type of surgery, age at the diagnosis time and number of removed positive lymph nodes. All analyses were performed using PROC MCMC processes in the SAS 9.2 program. The mean (SD) age of patients was equal to 48.9 (11.1) months. For these patients, 1, 5 and 10-year survival rates were 95, 79 and 50 percent respectively. All of the mentioned variables were effective in cure fraction. Kaplan-Meier curve showed cure model's use competence. Unlike other variables, existence of ER and PR positivity will increase probability of cure in patients. In the present study, Weibull distribution was used for the purpose of analysing survival times. Model fitness with other distributions such as log-N and log-logistic and other distributions for latent variable is recommended.
Ayzenberg, Mark; Narvaez, Michael; Raphael, James
2018-01-01
Casting is routinely used for acute and post-operative immobilization and remains a cornerstone in the non-operative management of fractures and deformities. The application of a properly fitted and wellmolded cast, especially for a trainee, can be challenging. We present a simple method of prolonging cure time of fiberglass cast — placing ice in the dip water. Eight-ply, fiveinch fiberglass cast was circumferentially applied to an aluminum-wrapped cardboard cylinder. An electronic, 2-channel temperature sensor (TR-71wf Temp Logger, T&D Corporation, Matsumoto, Japan), accurate to 0.1ºC and accurate to ±0.3ºC, was placed between the fourth and fifth layers of fiberglass. Thirty total casts were tested using 9±1ºC (cold), 22±1ºC (ambient), and 36±1ºC (warm) dip water. Room temperature was maintained at 24±1ºC. Cast temperatures were measured during the exothermic reaction generated by the cast curing. Peak temperatures and cure times were recorded. Cure time was defined as the point of downward deflection on the timetemperature curve immediately after peak. Cure and peak temperatures were compared among groups using analysis of variance. Mean cure time was 3.5±0.1 minutes for warm water, 5.0±0.4 minutes for ambient water and 7.0±0.5 minutes for cold water. Peak temperature, measured between layers 4 and 5 of the cast material, was 36.6±0.8ºC for warm water, 31.1±1.4ºC for ambient water and 25.2±0.5ºC for cold water. Cold afforded, on average, an additional 2 minutes (40% increase) in cure time compared to ambient water and an additional 3.5 minutes (100% increase) compared to warm water. Cure time differences were significant (P<0.001) for all groups, as were peak temperature differences (P<0.001). Temperatures concerning for development of burns were never reached. Utilizing iced dip water when casting is a simple and effective method to prolong the time available for cast application. Orthopedic residents and trainees may find this useful in learning to fabricate a high quality cast. For the experienced orthopedic surgeon, this method eliminates the need to bridge longlimb casts and facilitates the application of complex casts. PMID:29770174
Flooded Cell Permeation Testing of Elastomers
1994-03-01
cured hydrin (EC) elastomer 3. oxide cured neoprene (CR) 4. sulphur cured styrene-butadiene rubber (SBR) 5. sulphur cured nitrile rubber ( NBR ) 6. cured...Road Adelphi, MD 20783-1197 11. SUPPLEMENTARY NOTES Presented at the meeting of the American Chemical Society, Rubber Division, Orlando, Florida, 26 Oct...6 2. Permeation rate-time curve for DMSO through natural rubber ............................... 6 3. Permeation rate-time curve for DMSO through
NASA Astrophysics Data System (ADS)
Husnan, M. A.; Ismail, H.; Shuib, R. K.
2018-02-01
Recently, the interest of polymer industry researchers have grown rapidly on the use of specific techniques which can reduce cost and utilize rubber waste into the processing form. The increasing of cognizance in environmental matters and the desire to sustain the resources had fortified the practice of recycling waste materials. In this work, the effect of carbon black loading on curing characteristics and mechanical properties of virgin acrylonitrile butadiene rubber/recycled acrylonitrile butadiene rubber (NBRv/NBRr) blends were studied. Cure time (t90), scorch time (tS2) and swelling percentage decreased but minimum torque (ML) and maximum torque (MH) increased with increasing carbon black (CB) loading in the blends. Increasing CB loading also increased tensile strength, tensile modulus (M100), hardness and compression set but decreased elongation at break (Eb) of NBRv/NBRr blends.
The Effects of Long Term Cure on Offgassed Products of Coatings
NASA Technical Reports Server (NTRS)
Engle, Ginger; Whitfield, Steve
1997-01-01
The Environmental Chemistry and Compatability Team at The Marshall Space Flight Center conducts toxic offgassing analysis on materials and flight hardware for use in habitable environments aboard the Space Shuttle and the International Space Station. As part of Research and Development, the Toxic Offgassing Laboratory conducted a long term cure study on four polyurethane coatings which are slated for potential use on Space Station. This study demonstrates the effects of cure time and temperature on the total tox value (sum T) and the maximum usage weight for each coating. All analysis was conducted according to test procedures outlined specifically for Space Station environments. Therefore, the ratings and weight limits generated for these materials are most applicable to space environments. However, this test does give some indication of time frames for solvent removal and is therefore of interest to, the environmental community as a whole.
Tompkin, R B; Christiansen, L N; Shaparis, A B
1978-01-01
Perishable canned cured meat inoculated with Clostridium botulinum spores was placed at 4.4 or 10 degrees C after manufacture. Spore germination occurred at 10 degrees C. The germinated cell count remained stable over a period of 16 to 18 weeks. During that time period the inhibitory system and residual nitrite descreased. These factors combine to make perishable canned cured meats more prone to spoilage and potential hazard if they are temperature abused after a period of refrigerated storage. PMID:350155
Maiden, Nicholas R; Fisk, Wesley; Wachsberger, Christian; Byard, Roger W
2015-08-01
A study was undertaken to determine whether different concentrations of ordnance gelatine, water types, temperatures and curing times would have an effect on projectile penetration of a gelatine tissue surrogate. Both Federal Bureau of Investigation (FBI) and North Atlantic Treaty Organization (NATO) specified gelatines were compared against the FBI calibration standard. 10% w/w and 20% w/w concentrations of gelatine with Bloom numbers of 250 and 285 were prepared and cured at variable temperatures (3-20°C) for 21 hours-3 weeks. Each block was shot on four occasions on the same range using steel calibre 4.5 mm BBs fired from a Daisy(®) air rifle at the required standard velocity of 180 ± 4.5 m/s, to ascertain the mean penetration depth. The results showed no significant difference in mean penetration depth using the three different water types (p > 0.05). Temperature changes and curing times did affect penetration depth. At 10°C, mean penetration depth with 20% gelatine 285 Bloom for the two water types tested was 49.7 ± 1.5 mm after 21 h curing time, whereas the same formulation at 20°C using two different water types was 79.1 ± 2.1 mm after 100 h curing time (p < 0.001). Neither of the NATO 20% concentrations of gelatine at 10°C or a 20% concentration of 285 Bloom gelatine at 10°C met the same calibration standard as the FBI recommended 10% formulation at 4°C. A 20% concentration of 285 Bloom at 20°C met the same calibration/penetration criteria as a 10% concentration of 250 Bloom at 4 °C after 100 h of curing, therefore matching the FBI calibration standard for a soft tissue simulant for wound ballistics research. These results demonstrate significant variability in simulant properties. Failure to standardise ballistic simulants may invalidate experimental results. Copyright © 2015. Published by Elsevier Ltd.
Sm, Mousavinasab; M, Atai; N, Salehi; A, Salehi
2016-12-01
The degree of conversion depends on the material composition, light source properties, distance from light source, light intensity, curing time, and other factors such as shade and translucency. In the present study, we evaluated the effects of different light-curing modes and shades of methacrylate and silorane-based resin composites on the degree of conversion of resin composites (DC). The methacrylate-based (Filtek Z250, 3M, ESPE) and low-shrinkage silorane-based (Filtek P90, 3M, ESPE) resin composites were used in three groups as follows: group 1-Filtek Z250 (shade A3), group 2-Filtek Z250 (shade B2), and group 3-Filtek P90 (shade A3). We used a light-emitting diode (LED) curing unit for photopolymerization. 10 samples were prepared in each group to evaluate the degree of conversion; 5 samples were cured using soft-start curing mode, and the other 5 were cured using standard curing mode. The DC of the resin composites was measured using Fourier Transform Infrared Spectroscopy (FTIR). The data were analyzed using Kruskal Wallis and one-way ANOVA statistical tests. The degree of conversion of silorane-based resin composite was 70 - 75.8% and that of methacrylate-based resin composites was 60.2 - 68.2% (p = 0.009). The degree of conversion of the composite with brighter colour (B2) was statistically more than the darker composite (A3). Higher degree of conversion was achieved applying the standard curing mode. The results of the study showed that the colour and type of the resin composite and also the curing mode influence the degree of conversion of resin composites.
Can hepatic resection provide a long-term cure for patients with intrahepatic cholangiocarcinoma?
Spolverato, Gaya; Vitale, Alessandro; Cucchetti, Alessandro; Popescu, Irinel; Marques, Hugo P; Aldrighetti, Luca; Gamblin, T Clark; Maithel, Shishir K; Sandroussi, Charbel; Bauer, Todd W; Shen, Feng; Poultsides, George A; Marsh, J Wallis; Pawlik, Timothy M
2015-11-15
A patient can be considered statistically cured from a specific disease when their mortality rate returns to the same level as that of the general population. In the current study, the authors sought to assess the probability of being statistically cured from intrahepatic cholangiocarcinoma (ICC) by hepatic resection. A total of 584 patients who underwent surgery with curative intent for ICC between 1990 and 2013 at 1 of 12 participating institutions were identified. A nonmixture cure model was adopted to compare mortality after hepatic resection with the mortality expected for the general population matched by sex and age. The median, 1-year, 3-year, and 5-year disease-free survival was 10 months, 44%, 18%, and 11%, respectively; the corresponding overall survival was 27 months, 75%, 37%, and 22%, respectively. The probability of being cured of ICC was 9.7% (95% confidence interval, 6.1%-13.4%). The mortality of patients undergoing surgery for ICC was higher than that of the general population until year 10, at which time patients alive without tumor recurrence can be considered cured with 99% certainty. Multivariate analysis demonstrated that cure probabilities ranged from 25.8% (time to cure, 9.8 years) in patients with a single, well-differentiated ICC measuring ≤5 cm that was without vascular/periductal invasion and lymph nodes metastases versus <0.1% (time to cure, 12.6 years) among patients with all 6 of these risk factors. A model with which to calculate cure fraction and time to cure was developed. The cure model indicated that statistical cure was possible in patients undergoing hepatic resection for ICC. The overall probability of cure was approximately 10% and varied based on several tumor-specific factors. Cancer 2015;121:3998-4006. © 2015 American Cancer Society. © 2015 American Cancer Society.
Sindelar, J J; Cordray, J C; Sebranek, J G; Love, J A; Ahn, D U
2007-06-01
Uncured, no-nitrate/nitrite-added meat products can be manufactured with vegetable juice powder (VJP) and a starter culture containing Staphylococcus carnosus, resulting in quality and sensory attributes similar to traditional cured products. The 1st objective of this study was to determine the effects of varying concentrations of VJP and incubation times (MIN-HOLD) on quality characteristics, including lipid oxidation, color, and cured meat pigment concentrations, of emulsified-frankfurter-style-cooked (EFSC) sausages over a 90-d storage period. The 2nd objective was to compare residual nitrate and nitrite content resulting from different processing treatments and the 3rd objective was to assess sensory properties of finished products. Four EFSC sausage treatments (TRT) (TRT 1: 0.20% VJP, 30 MIN-HOLD; TRT 2: 0.20% VJP, 120 MIN-HOLD; TRT 3: 0.40% VJP, 30 MIN-HOLD; TRT 4: 0.40% VJP, 120 MIN-HOLD) and a sodium nitrite-added control (C) were used for this study. No differences for lipid oxidation (TBARS) between any TRTs and C or over time were observed. No differences (P > 0.05) for CIE L* values were found between TRTs. CIE a* and reflectance ratio values revealed that TRTs 2, 4, and C were redder than TRTs 1 and 3 at day 0. Trained sensory intensity ratings for cured aroma, cured color, cured flavor, uniform color, and firmness determined that all but TRT 1 were similar to C. These results indicate a longer incubation time (120 compared with 30 min) was found more critical than VJP level (0.20% or 0.40%) to result in products comparable to a sodium nitrite-added control.
Polymerization kinetics of experimental bioactive composites containing bioactive glass.
Par, Matej; Tarle, Zrinka; Hickel, Reinhard; Ilie, Nicoleta
2018-06-21
To investigate the polymerization kinetics and the degree of conversion (DC) of experimental resin composites with varying amount of bioactive glass 45S5 (BG). Experimental resin composites based on a photo-curable Bis-GMA/TEGDMA resin system were prepared. The composite series contained 0, 5, 10, 20, and 40 wt% of BG and reinforcing fillers up to the total filler amount of 70 wt%. Composite specimens were light cured with 1,219 mW/cm 2 for 20 or 40 s and their DC was monitored during 5 min at the data collection rate of 2 s -1 using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). The 5-min DC values for experimental composites were in the range of 42.4-55.9% and 47.3-57.9% for curing times of 20 and 40 s, respectively. The differences in the 5-min DC between curing times of 20 s or 40 s became more pronounced in materials with higher BG amount. Within both curing times, a decreasing trend of the 5-min DC values was observed with the increasing percentage of BG fillers. The maximum polymerization rate also decreased consistently with the increasing BG amount. Unsilanized BG fillers showed a dose-dependent inhibitory effect on polymerization rate and the DC. Extending the curing time from 20 to 40 s showed a limited potential to improve the DC of composites with higher BG amount. The observed inhibitory effect of BG fillers on the polymerization of resin composites may have a negative influence on mechanical properties and biocompatibility. Copyright © 2018. Published by Elsevier Ltd.
Investigation of Test Methods, Material Properties, and Processes for Solar Cell Encapsulants
NASA Technical Reports Server (NTRS)
Willis, P. B.
1981-01-01
Encapsulant materials and processes for the production of cost effective, long life solar cell modules are identified, and evaluated. Ethylene vinyl acetate lamination pottant studies are conducted with respect to the time/temperature cure requirements for successful use of this compound. The time needed to produce successful gel contents are redetermined at a variety of temperatures and are related to the peroxide half life temperature curve. Formulation of the butyl acrylate syrup casting pottant is complete. The formulation contains an ultraviolet stabilizer system and is cured with an initiator that presents no shipping or handling hazards. The catalyzed syrup is stable at room temperature and has a pot life of at least an eight hour period of time. The syrup cures to a transparent rubber in 18 minutes at a temperature of 60 C.
Alpöz, A. Riza; Ertuḡrul, Fahinur; Cogulu, Dilsah; Ak, Asli Topaloḡlu; Tanoḡlu, Metin; Kaya, Elçin
2008-01-01
Objectives The aim of this study was to investigate microhardness and compressive strength of composite resin (Tetric-Ceram, Ivoclar Vivadent), compomer (Compoglass, Ivoclar, Vivadent), and resin modified glass ionomer cement (Fuji II LC, GC Corp) polymerized using halogen light (Optilux 501, Demetron, Kerr) and LED (Bluephase C5, Ivoclar Vivadent) for different curing times. Methods Samples were placed in disc shaped plastic molds with uniform size of 5 mm diameter and 2 mm in thickness for surface microhardness test and placed in a diameter of 4 mm and a length of 2 mm teflon cylinders for compressive strength test. For each subgroup, 20 samples for microhardness (n=180) and 5 samples for compressive strength were prepared (n=45). In group 1, samples were polymerized using halogen light source for 40 seconds; in group 2 and 3 samples were polymerized using LED light source for 20 seconds and 40 seconds respectively. All data were analyzed by two way analysis of ANOVA and Tukey’s post-hoc tests. Results Same exposure time of 40 seconds with a low intensity LED was found similar or more efficient than a high intensity halogen light unit (P>.05), however application of LED for 20 seconds was found less efficient than 40 seconds curing time (P=.03). Conclusions It is important to increase the light curing time and use appropriate light curing devices to polymerize resin composite in deep cavities to maximize the hardness and compressive strength of restorative materials. PMID:19212507
Zhang, Z
1989-12-01
Cf, the methodology and diagnostic standard of 12 collaborative units about "Epidemiological investigation" of 1982, we traced to investigate the relation between the patients' condition outcome and drug maintain therapy of 324 cases with schizophrenia in community. The investigative result showed the cure rate of insisting on taking medicine group was 25.21%, the effective rate was 97.48%, the cure rate of irregular taking medicine groups was 6.63%, the effective rate was 68.37%, there was remarkable difference between the cure rate and the effective rate in two groups. Otherwise we also compared the patients, condition of insisting on taking drug groups with during investigation. We found there was no remarkable change that showed insisting a drug maintain therapy out the hospital to the curative effect of the disease to possess on important meaning. The pattern also compared the curative effect of a time onset of disease group and many times. There was no remarkable difference about the statistical analysis of the curative effect among each group. It showed me never lose confidence to the patients. We should treat actively them.
Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B
2016-01-01
Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.
Wang, Lijun; Zhang, Chun; Gong, Wei; Ji, Yubi; Qin, Shuhao; He, Li
2018-01-01
3D cross-linking networks are generated through chemical reactions between thermosetting epoxy resin and hardener during curing. The curing degree of epoxy material can be increased by increasing curing temperature and/or time. The epoxy material must then be fully cured through a postcuring process to optimize its material characteristics. Here, a limited-foaming method is introduced for the preparation of microcellular epoxy foams (Lim-foams) with improved cell morphology, high thermal expansion coefficient, and good compressive properties. Lim-foams exhibit a lower glass transition temperature (T g ) and curing degree than epoxy foams fabricated through free-foaming process (Fre-foams). Surprisingly, however, the T g of Lim-foams is unaffected by postcuring temperature and time. This phenomenon, which is related to high gas pressure in the bubbles, contradicts that indicated by the time-temperature-transformation cure diagram. High bubble pressure promotes the movement of molecular chains under heating at low temperature and simultaneously suppresses the etherification cross-linking reaction during post-curing. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cure modeling in real-time prediction: How much does it help?
Ying, Gui-Shuang; Zhang, Qiang; Lan, Yu; Li, Yimei; Heitjan, Daniel F
2017-08-01
Various parametric and nonparametric modeling approaches exist for real-time prediction in time-to-event clinical trials. Recently, Chen (2016 BMC Biomedical Research Methodology 16) proposed a prediction method based on parametric cure-mixture modeling, intending to cover those situations where it appears that a non-negligible fraction of subjects is cured. In this article we apply a Weibull cure-mixture model to create predictions, demonstrating the approach in RTOG 0129, a randomized trial in head-and-neck cancer. We compare the ultimate realized data in RTOG 0129 to interim predictions from a Weibull cure-mixture model, a standard Weibull model without a cure component, and a nonparametric model based on the Bayesian bootstrap. The standard Weibull model predicted that events would occur earlier than the Weibull cure-mixture model, but the difference was unremarkable until late in the trial when evidence for a cure became clear. Nonparametric predictions often gave undefined predictions or infinite prediction intervals, particularly at early stages of the trial. Simulations suggest that cure modeling can yield better-calibrated prediction intervals when there is a cured component, or the appearance of a cured component, but at a substantial cost in the average width of the intervals. Copyright © 2017 Elsevier Inc. All rights reserved.
Surgical Treatments for Infantile Purulent Meningitis Complicated by Subdural Effusion.
Wang, Xianshu; Zhang, Xiaoru; Cao, Hongbin; Jing, Shiyuan; Yang, Zhiguo; Cheng, Zhenghai; Liu, Ye; Li, Xin; Gao, Feifei; Ji, Yuanqi
2015-10-20
Infantile purulent meningitis (PM) is a commonly severe intracranial infectious disease in infants under age 1 year. In recent years, several diagnostic and treatment methods were reported, but in these cases the neurological complications and sequel were often observed, among which subdural effusion (SE) is the most common complication in PM. Timely diagnosis and early intervention are vital for better outcomes. In this study, the surgical treatments for infantile PM complicated by SE were investigated. Patients who had PM complicated by SE in the Children's Hospital of Hebei Province from June 2000 to June 2012 were retrospectively analyzed and 170 patients were enrolled in the study. Surgical treatment for each patient was adopted according to producing effusion time, leucocyte count, protein content, intracranial pressure, and bacteria culture, coupled with cranial ultrasound examination, CT, and MRI scans. Nearly, 15 patients were cured using serial taps, with a 50% cure rate. Seventeen out of 30 (56.6%) patients receiving subcutaneous reservoir drainage had better outcome. Nearly 80% of patients (55/69) who underwent minimally invasive trepanation and drainage were positive. Surgical procedure of minimally invasive trepanation and drainage combined with drug douche was effective in 63% of patients (19/30). In addition, 6 patients were cured with subdural-peritoneal shunt. Only 1 patient died, after the recurrence of meningitis, and the remaining 4 patients were cured by craniotomy. For infantile PM complicated with SE, treatment needs be chosen according to the specific situation. Surgical procedure of minimally invasive trepanation and drainage is a very effective treatment in curing PM complicated by SE. The treatment was highly effective with the use of drug douche. Subdural-peritoneal shunt and craniotomy were as effective as in refractory cases.
Surgical Treatments for Infantile Purulent Meningitis Complicated by Subdural Effusion
Wang, Xianshu; Zhang, Xiaoru; Cao, Hongbin; Jing, Shiyuan; Yang, Zhiguo; Cheng, Zhenghai; Liu, Ye; Li, Xin; Gao, Feifei; Ji, Yuanqi
2015-01-01
Background Infantile purulent meningitis (PM) is a commonly severe intracranial infectious disease in infants under age 1 year. In recent years, several diagnostic and treatment methods were reported, but in these cases the neurological complications and sequel were often observed, among which subdural effusion (SE) is the most common complication in PM. Timely diagnosis and early intervention are vital for better outcomes. In this study, the surgical treatments for infantile PM complicated by SE were investigated. Material/Methods Patients who had PM complicated by SE in the Children’s Hospital of Hebei Province from June 2000 to June 2012 were retrospectively analyzed and 170 patients were enrolled in the study. Surgical treatment for each patient was adopted according to producing effusion time, leucocyte count, protein content, intracranial pressure, and bacteria culture, coupled with cranial ultrasound examination, CT, and MRI scans. Results Nearly, 15 patients were cured using serial taps, with a 50% cure rate. Seventeen out of 30 (56.6%) patients receiving subcutaneous reservoir drainage had better outcome. Nearly 80% of patients (55/69) who underwent minimally invasive trepanation and drainage were positive. Surgical procedure of minimally invasive trepanation and drainage combined with drug douche was effective in 63% of patients (19/30). In addition, 6 patients were cured with subdural-peritoneal shunt. Only 1 patient died, after the recurrence of meningitis, and the remaining 4 patients were cured by craniotomy. Conclusions For infantile PM complicated with SE, treatment needs be chosen according to the specific situation. Surgical procedure of minimally invasive trepanation and drainage is a very effective treatment in curing PM complicated by SE. The treatment was highly effective with the use of drug douche. Subdural-peritoneal shunt and craniotomy were as effective as in refractory cases. PMID:26482715
NASA Astrophysics Data System (ADS)
Kim, Do-Kyung; Lee, Gyu-Jeong; Lee, Jae-Hyun; Kim, Min-Hoi; Bae, Jin-Hyuk
2018-05-01
We suggest a viable surface control method to improve the electrical properties of organic nonvolatile memory transistors. For viable surface control, the surface of the ferroelectric insulator in the memory field-effect transistors was modified using a smooth-contact-curing process. For the modification of the ferroelectric polymer, during the curing of the ferroelectric insulators, the smooth surface of a soft elastomer contacts intimately with the ferroelectric surface. This smooth-contact-curing process reduced the surface roughness of the ferroelectric insulator without degrading its ferroelectric properties. The reduced roughness of the ferroelectric insulator increases the mobility of the organic field-effect transistor by approximately eight times, which results in a high memory on–off ratio and a low-voltage reading operation.
Murthy, S Srinivasa; Murthy, Gargi S
2015-01-01
Background: Dentistry in general and prosthodontics in particular is evolving at greater pace, but the denture base resins poly methyl methacrylate. There has been vast development in modifying chemically and the polymerization techniques for better manipulation and enhancement of mechanical properties. One such invention was introduction of visible light cure (VLC) denture base resin. Argon ion lasers have been used extensively in dentistry, studies has shown that it can polymerize restorative composite resins. Since composite resin and VLC resin share the same photo initiator, Argon laser is tested as activator for polymerizing VLC resin. In the Phase 1 study, the VLC resin was evaluated for exposure time for optimum polymerization using argon ion laser and in Phase 2; flexural strength, impact strength, surface hardness and surface characteristics of laser cured resin was compared with light cure and conventional heat cure resin. Materials and Methods: Phase 1; In compliance with American Dental Association (ADA) specification no. 12, 80 samples were prepared with 10 each for different curing time using argon laser and evaluated for flexural strength on three point bend test. Results were compared to established performance requirement specified. Phase 2, 10 specimen for each of the mechanical properties (30 specimen) were polymerized using laser, visible light and heat and compared. Surface and fractured surface of laser, light and heat cured resins were examined under scanning electron microscope (SEM). Results: In Phase 1, the specimen cured for 7, 8, 9 and 10 min fulfilled ADA requirement. 8 min was taken as suitable curing time for laser curing. Phase 2 the values of mechanical properties were computed and subjected to statistical analysis using one-way ANOVA and Tukey post-hoc test. The means of three independent groups showed significant differences between any two groups (P < 0.001). Conclusion: Triad VLC resin can be polymerized by argon ion laser with 1 W/mm2 power and exposure time of 8 min to satisfy ADA specification. Impact strength, surface hardness of laser cure was better than light cure and heat cure resin. Flexural strength of light cure was better than laser cure and heat cure resin. The SEM study showed similar density on surface, the fractured surface of heat cure resin was dense and compact. PMID:26124596
Chai, Mei; Tang, Xuyan; Liang, Guangku
2015-12-01
To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo. A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures. There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor. Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.
Light curing in orthodontics; should we be concerned?
McCusker, Neil; Lee, Siu Man; Robinson, Stephen; Patel, Naresh; Sandy, Jonathan R; Ireland, Anthony J
2013-06-01
Light cured materials are increasingly used in orthodontic clinical practice and concurrent with developments in materials have been developments in light curing unit technology. In recent years the irradiances of these units have increased. The aim of this study was to determine the safe exposure times to both direct and reflected light. The weighted irradiance and safe exposure times of 11 dental curing lights (1 plasma arc, 2 halogen and 8 LED lights) were determined at 6 distances (2-60 cm) from the light guide tip using a spectroradiometer. In addition, using the single most powerful light, the same two parameters were determined for reflected light. This was done at a distance of 10 cm from the reflected light, but during simulated bonding of 8 different orthodontic brackets of three material types, namely stainless steel, ceramic and composite. The results indicate that the LED Fusion lamp had the highest weighted irradiance and the shortest safe exposure time. With this light the maximum safe exposure time without additional eye protection for the patient (at 10 cm), the operator (at 30 cm) and the assistant (at 60 cm) ranged from 2.5 min, 22.1 min and 88.8 min respectively. This indicates a relatively low short term risk during normal operation of dental curing lights. For reflected light at a distance of 10 cm the risk was even lower, but was affected by the material and shape of the orthodontic bracket under test. The short term risks associated with the use of dental curing lights, halogen, LED or plasma, appear to be low, particularly if as is the case adequate safety precautions are employed. The same is true for reflected light from orthodontic brackets during bonding. What is still unclear is the potential long term ocular effects of prolonged exposure to the blue light generated from dental curing lights. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Cationic cure kinetics of a polyoxometalate loaded epoxy nanocomposite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Benjamin J.
2012-08-06
The reaction cure kinetics of a novel polyoxometalate (POM) loaded epoxy nanocomposite is described. The POM is dispersed in the epoxy resin up to volume fractions of 0.1. Differential scanning calorimetry measurements show the cure of the epoxy resin to be sensitive to the POM loading. A kinetics study of the cure exotherm confirms that POM acts as a catalyst promoting cationic homopolymerization of the epoxy resin. The cure reaction is shown to propagate through two cure regimes. A fast cure at short time is shown to be propagation by the activated chain end (ACE) mechanism. A slow cure atmore » long time is shown to be propagation by the activated monomer (AM) mechanism. The activation energies for the fast and slow cure regimes agree well with other epoxy based systems that have been confirmed to propagate by the ACE and AM mechanisms.« less
Dingwell, R T; Leslie, K E; Duffield, T F; Schukken, Y H; DesCoteaux, L; Keefe, G P; Kelton, D F; Lissemore, K D; Shewfelt, W; Dick, P; Bagg, R
2003-01-01
The objective ofthis study was to evaluate the efficacy of intramammary tilmicosin, administered at drying-off, for eliminating Staphylococcus aureus infection, and to identify risk factors for S. aureus cure during the dry period. A total of 219 naturally infected cows, representing 308 quarters, were randomized to receive either one of two treatments at drying-off. Cows received either an intramammary infusion of 500 mg of benzathine cloxacillin, or a sterile solution containing 1,500 mg of tilmicosin. All cows had quarter milk samples taken aseptically three times before dry-off, and at wk 1, 2, and 4 of the subsequent lactation. Overall, 62% of cows and 67.5% of quarters infected with S. aureus cured during the dry period. The cure following administraton of tilmicosin was 67.3 and 72.5% for cows and quarters, respectively. By comparison, the cure achieved with cloxacillin was 56.9 and 62.9% of cows and quarters. Cows receiving tilmicosin were 2.1 times more likely to cure. The cure rate for cows decreased as the linear score on the last DHI test increased, and as the amount of S. aureus being shed increased. Quarters that cultured positive multiple times before drying-off were less likely to cure. Staphylococcus aureus infections located in front quarters of the udder were 2 times more likely to cure than those in hind quarters. Results of this study demonstrate that intramammary tilmicosin at drying-off is efficacious in curing existing S. aureus during the dry period. Risk factors associated with the cure of S. aureus were identified.
Matan, N; Matan, N; Ketsa, S
2013-08-01
This study aimed to examine heat curing effect (30-100°C) on antifungal activities of lime oil and its components (limonene, p-cymene, β-pinene and α-pinene) at concentrations ranging from 100 to 300 μl ml(-1) against Aspergillus niger in microbiological medium and to optimize heat curing of lime oil for efficient mould control on sedge (Lepironia articulata). Broth dilution method was employed to determine lime oil minimum inhibitory concentration, which was at 90 μl ml(-1) with heat curing at 70°C. Limonene, a main component of lime oil, was an agent responsible for temperature dependencies of lime oil activities observed. Response surface methodology was used to construct the mathematical model describing a time period of zero mould growth on sedge as functions of heat curing temperature and lime oil concentration. Heat curing of 90 μl ml(-1) lime oil at 70°C extended a period of zero mould growth on sedge to 18 weeks under moist conditions. Heat curing at 70°C best enhanced antifungal activity of lime oil against A. niger both in medium and on sedge. Heat curing of lime oil has potential to be used to enhance the antifungal safety of sedge products. © 2013 The Society for Applied Microbiology.
Color Developing Capacity of Plasma-treated Water as a Source of Nitrite for Meat Curing.
Jung, Samooel; Kim, Hyun Joo; Park, Sanghoo; Yong, Hae In; Choe, Jun Ho; Jeon, Hee-Joon; Choe, Wonho; Jo, Cheorun
2015-01-01
The interaction of plasma with liquid generates nitrogen species including nitrite (NO(-) 2). Therefore, the color developing capacity of plasma-treated water (PTW) as a nitrite source for meat curing was investigated in this study. PTW, which is generated by surface dielectric barrier discharge in air, and the increase of plasma treatment time resulted in increase of nitrite concentration in PTW. The PTW used in this study contains 46 ppm nitrite after plasma treatment for 30 min. To evaluate the effect of PTW on the cured meat color, meat batters were prepared under three different conditions (control, non-cured meat batter; PTW, meat batter cured with PTW; Sodium nitrite, meat batter cured with sodium nitrite). The meat batters were vacuum-packaged and cooked in a water-bath at 80℃ for 30 min. The typical color of cured meat developed in cooked meat batter treated with sodium nitrite or PTW. The lightness (L*) and yellowness (b*) values were similar in all conditions, whereas, the redness (a*) values of cooked meat batter with PTW and sodium nitrite (p<0.05) were significantly higher than the control. These data indicate that PTW can be used as a nitrite source in the curing process of meat without addition of other nitrite sources.
Color Developing Capacity of Plasma-treated Water as a Source of Nitrite for Meat Curing
Jung, Samooel; Kim, Hyun Joo; Park, Sanghoo; Choe, Jun Ho; Jeon, Hee-Joon; Choe, Wonho
2015-01-01
The interaction of plasma with liquid generates nitrogen species including nitrite (NO−2). Therefore, the color developing capacity of plasma-treated water (PTW) as a nitrite source for meat curing was investigated in this study. PTW, which is generated by surface dielectric barrier discharge in air, and the increase of plasma treatment time resulted in increase of nitrite concentration in PTW. The PTW used in this study contains 46 ppm nitrite after plasma treatment for 30 min. To evaluate the effect of PTW on the cured meat color, meat batters were prepared under three different conditions (control, non-cured meat batter; PTW, meat batter cured with PTW; Sodium nitrite, meat batter cured with sodium nitrite). The meat batters were vacuum-packaged and cooked in a water-bath at 80℃ for 30 min. The typical color of cured meat developed in cooked meat batter treated with sodium nitrite or PTW. The lightness (L*) and yellowness (b*) values were similar in all conditions, whereas, the redness (a*) values of cooked meat batter with PTW and sodium nitrite (p<0.05) were significantly higher than the control. These data indicate that PTW can be used as a nitrite source in the curing process of meat without addition of other nitrite sources. PMID:26761900
NASA Astrophysics Data System (ADS)
Raharja, Danang S.; Hadiwardoyo, Sigit P.; Rahayu, Wiwik; Zain, Nasuhi
2017-06-01
Geopolymer is binder material that consists of solid material and the activator solution. Geopolymer material has successfully replaced cement in the manufacture of concrete with aluminosilicate bonding system. Geopolymer concrete has properties similar to cement concrete with high compressive strength, low shrinkage value, relatively low creep value, as well as acid-resistant. Based on these, the addition of polymers in peat soils is expected to improve the bearing capacity of peat soils. A study on the influence of geopolymer addition in peat soils was done by comparing before and after the peat soil was mixed with geopolymer using CBR (California Bearing Ratio) test in unsoaked and soaked conditions. 10% mixture content of the peat dry was used, weighted with a variety of curing time 4 hours, 5 days, and 10 days. There were two methods of mixing: first, peat was mixed with fly ash geopolymer activators and mixed solution (waterglass, NaOH, water), and second, peat was mixed with fly ash and mixed geopolymer (waterglass, NaOH, water, fly ash). Changes were observed in specific gravity, dry density, acidity (pH), and the microscopic structure with Scanning Electron Microscope (SEM). Curing time did not significantly affect the CBR value. It even shows a tendency to decline with longer curing time. The first type mixture obtained CBR value of: 5.4% for 4 hours curing, 4.6% for 5 days curing and 3.6% for 10 days curing. The second type mixture obtained CBR value of: 6.1% for 4 hours curing, 5.2% for 5 days curing and 5.2% for 10 days curing. Furthermore, the specific gravity value, dry density, pH near neutral and swelling percentage increased. From both variants, the second type mixture shows better results than the first type mixture. The results of SEM (Scanning Electron Microscopy) show the structure of the peat which became denser with the fly ash particles filling the peat microporous. Also, the reaction of fly ash with geopolymer is indicated by the solid agglomerates that are larger than normal fly ash particle size.
Bayarri, Susana; Gracia, María J; Lázaro, Regina; Pe Rez-Arquillué, Consuelo; Barberán, Montserrat; Herrera, Antonio
2010-12-01
Toxoplasmosis is a zoonotic disease caused by the protozoan Toxoplasma gondii and distributed worldwide. Ingestion of viable cysts from infected raw or undercooked meat is an important route of horizontal transmission of the parasite to humans. Little information is available concerning the effect of commercial curing on cysts of T. gondii. This study is the first in which the influence of processing of cured ham on the viability of T. gondii has been evaluated, using bioassay to assess the risk of infection from eating this meat product. Naturally infected pigs were selected for the study, and a mouse concentration bioassay technique was used to demonstrate viable bradyzoites of T. gondii in porcine tissues and hams. No viable parasites were found in the final product (14 months of curing) based on results of the indirect immunofluorescence assay and histological and PCR analyses. Our results indicate that the consumption of hams cured as described here poses an insignificant risk of acquiring toxoplasmosis. However, additional studies are required to evaluate the safety of ham products cured under different conditions of curing time, salt, and nitrite concentration.
Monitoring the Cure State of Thermosetting Resins by Ultrasound.
Lionetto, Francesca; Maffezzoli, Alfonso
2013-09-05
The propagation of low intensity ultrasound in a curing resin, acting as a high frequency oscillatory excitation, has been recently proposed as an ultrasonic dynamic mechanical analysis (UDMA) for cure monitoring. The technique measures sound velocity and attenuation, which are very sensitive to changes in the viscoelastic characteristics of the curing resin, since the velocity is related to the resin storage modulus and density, while the attenuation is related to the energy dissipation and scattering in the curing resin. The paper reviews the results obtained by the authors' research group in the last decade by means of in-house made ultrasonic set-ups for both contact and air-coupled ultrasonic experiments. The basics of the ultrasonic wave propagation in polymers and examples of measurements of the time-evolution of ultrasonic longitudinal modulus and chemical conversion of different thermosetting resins are presented. The effect of temperature on the cure kinetics, the comparison with rheological, low frequency dynamic mechanical and calorimetric results, and the correlation between ultrasonic modulus and crosslinking density will be also discussed. The paper highlights the reliability of ultrasonic wave propagation for monitoring the physical changes taking place during curing and the potential for online monitoring during polymer and polymer matrix composite processing.
Monitoring the Cure State of Thermosetting Resins by Ultrasound
Lionetto, Francesca; Maffezzoli, Alfonso
2013-01-01
The propagation of low intensity ultrasound in a curing resin, acting as a high frequency oscillatory excitation, has been recently proposed as an ultrasonic dynamic mechanical analysis (UDMA) for cure monitoring. The technique measures sound velocity and attenuation, which are very sensitive to changes in the viscoelastic characteristics of the curing resin, since the velocity is related to the resin storage modulus and density, while the attenuation is related to the energy dissipation and scattering in the curing resin. The paper reviews the results obtained by the authors’ research group in the last decade by means of in-house made ultrasonic set-ups for both contact and air-coupled ultrasonic experiments. The basics of the ultrasonic wave propagation in polymers and examples of measurements of the time-evolution of ultrasonic longitudinal modulus and chemical conversion of different thermosetting resins are presented. The effect of temperature on the cure kinetics, the comparison with rheological, low frequency dynamic mechanical and calorimetric results, and the correlation between ultrasonic modulus and crosslinking density will be also discussed. The paper highlights the reliability of ultrasonic wave propagation for monitoring the physical changes taking place during curing and the potential for online monitoring during polymer and polymer matrix composite processing. PMID:28788306
Ramos-Tonello, Carla M; Lisboa-Filho, Paulo N; Arruda, Larisa B; Tokuhara, Cintia K; Oliveira, Rodrigo C; Furuse, Adilson Y; Rubo, José H; Borges, Ana Flávia S
2017-07-01
This study has investigated the influence of Titanium dioxide nanotubes (TiO 2 -nt) addition to self-adhesive resin cement on the degree of conversion, water sorption, and water solubility, mechanical and biological properties. A commercially available auto-adhesive resin cement (RelyX U200™, 3M ESPE) was reinforced with varying amounts of nanotubes (0.3, 0.6, 0.9wt%) and evaluated at different curing modes (self- and dual cure). The DC in different times (3, 6, 9, 12 and 15min), water sorption (Ws) and solubility (Sl), 3-point flexural strength (σf), elastic modulus (E), Knoop microhardness (H) and viability of NIH/3T3 fibroblasts were performed to characterize the resin cement. Reinforced self-adhesive resin cement, regardless of concentration, increased the DC for the self- and dual-curing modes at all times studied. The concentration of the TiO 2 -nt and the curing mode did not influence the Ws and Sl. Regarding σf, concentrations of both 0.3 and 0.9wt% for self-curing mode resulted in data similar to that of dual-curing unreinforced cement. The E increased with the addition of 0.9wt% for self-cure mode and H increased with 0.6 and 0.9wt% for both curing modes. Cytotoxicity assays revealed that reinforced cements were biocompatible. TiO 2 -nt reinforced self-adhesive resin cement are promising materials for use in indirect dental restorations. Taken together, self-adhesive resin cement reinforced with TiO 2 -nt exhibited physicochemical and mechanical properties superior to those of unreinforced cements, without compromising their cellular viability. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Giorgini, Loris; Mazzocchetti, Laura; Minak, Giangiacomo; Dolcini, Enrico
2012-07-01
A case-study is presented, in cooperation with RI-BA Composites srl, where the industrial production of a thick part for primary structural application is analysed. The final product is a bulk carbon fiber reinforced object characterized by great dimensions, with thickness ranging between 10mm and 35mm and obtained by Hand-Lay-Up of prepregs. The study shows that prepregs age along the time required for the process work up. Moreover, the isothermal curing investigation of the prepreg used in the production gives some useful hint for the design of a new thermal curing cycle, in order to avoid exotherm problems along the thickness of the object. The effect of the applied curing cycle on thermal properties of the object are reported.
Slide Rule For Calculating Curing Schedules
NASA Technical Reports Server (NTRS)
Heater, Don
1995-01-01
Special-purpose slide rule devised for calculating schedules for storing and curing adhesives, sealants, and other materials characterized by known curing times and shelf lives. Prevents mistakes commonly made in determining storage and curing schedules.
Frey, Melissa K; Ellis, Annie E; Koontz, Laura M; Shyne, Savannah; Klingenberg, Bernhard; Fields, Jessica C; Chern, Jing-Yi; Blank, Stephanie V
2017-08-01
Women with ovarian cancer can have long overall survival and goals of treatment change over time from cure to remission to stable disease. We sought to determine whether survivors' acceptance of treatment side effects also changes over the disease continuum. Women with ovarian cancer completed an online survey focusing on survivors' goals and priorities. The survey was distributed through survivor networks and social media. Four hundred and thirty-four women visited the survey website and 328 (76%) completed the survey. Among participants, 141 (43%) identified themselves as having ever recurred, 119 (36%) were undergoing treatment at the time of survey completion and 86 (26%) had received four or more chemotherapy regimens. Respondents' goals of care were cure for 115 women (35%), remission for 156 (48%) and stable disease for 56 (17%). When asked what was most meaningful, 148 women (45%) reported overall survival, 135 (41%) reported quality of life and 40 (12%) reported progression-free survival. >50% of survivors were willing to tolerate the following symptoms for the goal of cure: fatigue (283, 86%), alopecia (281, 86%), diarrhea (232, 71%), constipation (227, 69%), neuropathy (218, 66%), arthralgia (210, 64%), sexual side effects (201, 61%), reflux symptoms (188, 57%), memory loss (180, 55%), nausea/vomiting (180, 55%), hospitalization for treatment side effects (179, 55%) and pain (169, 52%). The rates of tolerance for most symptoms decreased significantly as the goal of treatment changed from cure to remission to stable disease. Women with ovarian cancer willingly accept many treatment side effects when the goal of treatment is cure, however become less accepting when the goal is remission and even less so when the goal is stable disease. Physicians and survivors must carefully consider treatment toxicities and quality of life effects when selecting drugs for patients with incurable disease. Copyright © 2017 Elsevier Inc. All rights reserved.
Khan, M A; Walley, J D; Witter, S N; Imran, A; Safdar, N
2002-06-01
An economic study was conducted alongside a clinical trial at three sites in Pakistan to establish the costs and effectiveness of different strategies for implementing directly observed treatment (DOT) for tuberculosis. Patients were randomly allocated to one of three arms: DOTS with direct observation by health workers (at health centres or by community health workers); DOTS with direct observation by family members; and DOTS without direct observation. The clinical trial found no statistically significant difference in cure rate for the different arms. The economic study collected data on the full range of health service costs and patient costs of the different treatment arms. Data were also disaggregated by gender, rural and urban patients, by treatment site and by economic categories, to investigate the costs of the different strategies, their cost-effectiveness and the impact that they might have on patient compliance with treatment. The study found that direct observation by health centre-based health workers was the least cost-effective of the strategies tested (US dollars 310 per case cured). This is an interesting result, as this is the model recommended by the World Health Organization and International Union against Tuberculosis and Lung Disease. Attending health centres daily during the first 2 months generated high patient costs (direct and in terms of time lost), yet cure rates for this group fell below those of the non-observed group (58%, compared with 62%). One factor suggested by this study is that the high costs of attending may be deterring patients, and in particular, economically active patients who have most to lose from the time taken by direct observation. Without stronger evidence of benefits, it is hard to justify the costs to health services and patients that this type of direct observation imposes. The self-administered group came out as most cost-effective (164 dollars per case cured). The community health worker sub-group achieved the highest cure rates (67%), with a cost per case only slightly higher than the self-administered group (172 dollars per case cured). This approach should be investigated further, along with other approaches to improving patient compliance.
Methods for analysis of the occurrence of abscess in patients with pancreatitis.
Roca-Antonio, J; Escudero, L E; Gener, J; Oller, B; Rodríguez, N; Muñoz, A
1997-01-01
Standard survival analysis methods are useful for data involving censored cases when cures do not generally occur. If the object is to study, for instance, the development of a complication in the progress of an infectious disease, some people may be cured before complications develop. In this article, we provide methods for the analysis of data when cures do occur. An example is a study of prognostic factors for pancreatic abscess in patients with pancreatitis, some of whom leave the risk set because the pancreatitis clears. We present methods for estimating the survival curves and comparing hazard function for two objectives: (1) the occurrence of an abscess, irrespective of whether the patients are cured or not, and (2) the occurrence of an abscess for patients who, at that stage, have not been cured. We illustrate the applications of the methods using a sample of 50 patients with severe pancreatitis. To study the occurrence of an abscess, regardless of whether the patients are cured or not, we show that the appropriate strategy is to assign to the cured patients an infinite time to the appearance of an abscess. If the cured were considered censored at the moment the pancreatitis cleared, this would result in an overestimation of the hazard of presenting an abscess. On the other hand, if the objective is to compare the occurrence of abscess according to an exposure for patients who have not been cured, one needs to censor the cured patients at the time they are cured. For the analysis of survival data in the context of infectious diseases when cure is possible, it is important to use a censoring strategy that is pertinent to the specific aims of the study. Considering cures as censored at the time of cure is not always appropriate.
Post-irradiation hardening of dual-cured and light-cured resin cements through machinable ceramics.
Yoshida, Keiichi; Atsuta, Mitsuru
2006-10-01
To evaluate the surface hardness (Knoop Hardness Number) of the thin layer in three light-cured and dual-cured resin cements irradiated through or not through 2.0 mm thick machinable ceramics. A piece of adhesive polyethylene tape with a circular hole was positioned on the surface of the ceramic plate to control the cement layer (approximately 50 microm). The cement paste was placed on the ceramic surface within the circle. The ceramic plate with resin cement paste was placed on a clear micro cover glass over a zirconia ceramic block to obtain a flat surface, and the material was polymerized using a visible-light-curing unit. The surface hardness was recorded at a series of time intervals up to 5 days, starting from the end of a light-irradiation period. The hardness steadily increased with post-irradiation time and tended towards a maximum, usually reached after 1 or 2 days. In all cases, the increase in hardness was relatively rapid over the first 30 minutes and continued at a lower rate thereafter. The dual-cured resin cement for each material showed a significantly higher hardness value than the light-cured resin cement irradiated either through or not through ceramics at all post-irradiation times. The resin cements cured through ceramic for each material were significantly less hard compared with those cured not through ceramics at all post-irradiation times.
A flexible cure rate model with dependent censoring and a known cure threshold.
Bernhardt, Paul W
2016-11-10
We propose a flexible cure rate model that accommodates different censoring distributions for the cured and uncured groups and also allows for some individuals to be observed as cured when their survival time exceeds a known threshold. We model the survival times for the uncured group using an accelerated failure time model with errors distributed according to the seminonparametric distribution, potentially truncated at a known threshold. We suggest a straightforward extension of the usual expectation-maximization algorithm approach for obtaining estimates in cure rate models to accommodate the cure threshold and dependent censoring. We additionally suggest a likelihood ratio test for testing for the presence of dependent censoring in the proposed cure rate model. We show through numerical studies that our model has desirable properties and leads to approximately unbiased parameter estimates in a variety of scenarios. To demonstrate how our method performs in practice, we analyze data from a bone marrow transplantation study and a liver transplant study. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Ghavami, Vahid; Mahmoudi, Mahmood; Rahimi Foroushani, Abbas; Baghishani, Hossein; Homaei Shandiz, Fatemeh; Yaseri, Mehdi
2017-10-26
Introduction: Survival modeling is a very important tool to detect risk factors and provide a basis for health care planning. However, cancer data may have properties leading to distorted results with routine methods. Therefore, this study aimed to cover specific factors (competing risk, cure fraction and heterogeneity) with a real dataset of Iranian breast cancer patients using a competing risk-cure-frailty model. Materials and methods: For this historical cohort study, information for 550 Iranian breast cancer patients who underwent surgery for tumor removal from 2001 to 2007 and were followed up to March 2017, was analyzed using R 3.2 software. Results: In contrast to T-stage and N-stage, hormone receptor status did not have any significant effect on the cure fraction (long-term disease-free survival). However, T-stage, N-stage and hormone receptor status all had a significant effect on short-term disease-free survival so that the hazard of loco-regional relapse or distant metastasis in cases positive for a hormone receptor was only 0.3 times that for their negative hormone receptor counterparts. The likelihood of locoregional relapse in the first quartile of follow up was nearly twice that of other quartiles. The least cumulative incidence of time to locoregional relapse was for cases with a positive hormone receptor, low N stage and low T stage. The effect of frailty term was significant in this study and a model with frailty appeared more appropriate than a model without, based on the Akaike information criterion (AIC); values for the frailty model and one without the frailty parameter were 1370.39 and 1381.46, respectively. Conclusions: The data from this study indicate ae necessity to consider competing risk, cure fraction and heterogeneity in survival modeling. The competing risk-cure-frailty model can cover complex situations with survival data. Creative Commons Attribution License
Flury, Simon; Lussi, Adrian; Hickel, Reinhard; Ilie, Nicoleta
2013-12-01
The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance-Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Maximum irradiances were 1,545 mW/cm(2) (SM), 2,179 mW/cm(2) (HPM), and 4,156 mW/cm(2) (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.
Acoustic emission analysis of tooth-composite interfacial debonding.
Cho, N Y; Ferracane, J L; Lee, I B
2013-01-01
This study detected tooth-composite interfacial debonding during composite restoration by means of acoustic emission (AE) analysis and investigated the effects of composite properties and adhesives on AE characteristics. The polymerization shrinkage, peak shrinkage rate, flexural modulus, and shrinkage stress of a methacrylate-based universal hybrid, a flowable, and a silorane-based composite were measured. Class I cavities on 49 extracted premolars were restored with 1 of the 3 composites and 1 of the following adhesives: 2 etch-and-rinse adhesives, 2 self-etch adhesives, and an adhesive for the silorane-based composite. AE analysis was done for 2,000 sec during light-curing. The silorane-based composite exhibited the lowest shrinkage (rate), the longest time to peak shrinkage rate, the lowest shrinkage stress, and the fewest AE events. AE events were detected immediately after the beginning of light-curing in most composite-adhesive combinations, but not until 40 sec after light-curing began for the silorane-based composite. AE events were concentrated at the initial stage of curing in self-etch adhesives compared with etch-and-rinse adhesives. Reducing the shrinkage (rate) of composites resulted in reduced shrinkage stress and less debonding, as evidenced by fewer AE events. AE is an effective technique for monitoring, in real time, the debonding kinetics at the tooth-composite interface.
NASA Astrophysics Data System (ADS)
Knoth, Kenneth Charles
Course-based undergraduate research experiences (CUREs) provide authentic research benefits to an entire laboratory course population. CURE experiences are proposed to enhance research skills, critical thinking, productivity, and retention in science. CURE curriculum developers face numerous obstacles, such as the logistics and time commitment involved in bringing a CURE to larger student populations. In addition, an ideal CURE topic requires affordable resources, lab techniques that can be quickly mastered, time for multiple iterations within one semester, and the opportunity to generate new data. This study identifies some of the CURE activities that lead to proposed participant outcomes. Introductory Biology I CURE lab students at Southern Illinois University Edwardsville completed research related to the process of converting storage lipids in microalgae into biodiesel. Data collected from CURE and traditional lab student participants indicate increased CURE student reports of project ownership, scientific self-efficacy, identification as a scientist, and sense of belonging to a science community. Study limitations and unanticipated benefits are discussed.
7 CFR 58.412 - Coolers or curing rooms.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...
7 CFR 58.412 - Coolers or curing rooms.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...
7 CFR 58.412 - Coolers or curing rooms.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...
7 CFR 58.412 - Coolers or curing rooms.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...
7 CFR 58.412 - Coolers or curing rooms.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...
A comparative study of mixture cure models with covariate
NASA Astrophysics Data System (ADS)
Leng, Oh Yit; Khalid, Zarina Mohd
2017-05-01
In survival analysis, the survival time is assumed to follow a non-negative distribution, such as the exponential, Weibull, and log-normal distributions. In some cases, the survival time is influenced by some observed factors. The absence of these observed factors may cause an inaccurate estimation in the survival function. Therefore, a survival model which incorporates the influences of observed factors is more appropriate to be used in such cases. These observed factors are included in the survival model as covariates. Besides that, there are cases where a group of individuals who are cured, that is, not experiencing the event of interest. Ignoring the cure fraction may lead to overestimate in estimating the survival function. Thus, a mixture cure model is more suitable to be employed in modelling survival data with the presence of a cure fraction. In this study, three mixture cure survival models are used to analyse survival data with a covariate and a cure fraction. The first model includes covariate in the parameterization of the susceptible individuals survival function, the second model allows the cure fraction to depend on covariate, and the third model incorporates covariate in both cure fraction and survival function of susceptible individuals. This study aims to compare the performance of these models via a simulation approach. Therefore, in this study, survival data with varying sample sizes and cure fractions are simulated and the survival time is assumed to follow the Weibull distribution. The simulated data are then modelled using the three mixture cure survival models. The results show that the three mixture cure models are more appropriate to be used in modelling survival data with the presence of cure fraction and an observed factor.
de Lana, Marta; Martins-Filho, Olindo Assis
2015-01-01
One of the most relevant issues beyond the effectiveness of etiological treatment of Chagas disease is the lack of consensual/feasible tools to identify and certify the definitive parasitological cure. Several methods of distinct natures (parasitological, serological, and molecular) have been continuously proposed and novel perspectives are currently under investigation. Although the simultaneous use of distinct tests may offer better contributions and advances, it also leads to controversies of interpretation, with lack of mutual consent of cure criterion amongst researchers and physicians. In fact, when distinct host compartments (blood/tissues) are evaluated and explored, novel questions may arise due to the nature and sensitivity limit of each test. This short analytical review intends to present a chronological and critical overview and discuss the state-of-the-art distinct devices available for posttherapeutic cure assessment in Chagas disease, their contributions, meanings, and interpretation, aiming to point out the major gaps and propose novel insight for future perspectives of posttherapeutic management of Chagas disease patients. PMID:26583124
Purriños, Laura; García Fontán, María C; Carballo, Javier; Lorenzo, José M
2013-05-01
The aim of this work was to study the yeast population during the manufacture of dry-cured "lacón" (a Spanish traditional meat product) and the effect of the salting time. For this study, six batches of "lacón" were manufactured with three different salting times (LS (3 days of salting), MS (4 days of salting) and HS (5 days of salting)). Yeast counts increased significantly (P < 0.001) during the whole process from 2.60 to 6.37 log cfu/g. An increased length of salting time did not affect yeast counts throughout the manufacture of dry-cured "lacón", although the highest yeast counts were obtained from LS batches. A total of 226 isolates were obtained from dry-cured "lacón" during drying-ripening stage, of which 151 were yeasts and were identified at the species level using molecular techniques. The total of 151 identified yeasts belonged to 4 different genera: Debaryomyces, Candida, Cryptococcus and Rhodotorula. Debaryomyces hansenii was the most abundant species isolated throughout the whole process as much in the interior as in the exterior of the pieces of three salt levels of "lacón" studied, while Candida zeylanoides was only isolated from the interior of MS and HS batches and from the exterior of LS and HS groups, but at lesser proportion than D. hansenii. Copyright © 2012. Published by Elsevier Ltd.
D'Arcangelo, Camillo; De Angelis, Francesco; Vadini, Mirco; Carluccio, Fabio; Vitalone, Laura Merla; D'Amario, Maurizio
2012-08-01
To assess the microhardness of three resin composites employed in the adhesive luting of indirect composite restorations and examine the influence of the overlay material and thickness as well as the curing time on polymerization rate. Three commercially available resin composites were selected: Enamel Plus HRI (Micerium) (ENA), Saremco ELS (Saremco Dental) (SAR), Esthet-X HD (Dentsply/DeTrey) (EST-X). Post-polymerized cylinders of 6 different thicknesses were produced and used as overlays: 2 mm, 3 mm, 3.5 mm, 4 mm, 5 mm, and 6 mm. Two-mm-thick disks were produced and employed as underlays. A standardized amount of composite paste was placed between the underlay and the overlay surfaces which were maintained at a fixed distance of 0.5 mm. Light curing of the luting composite layer was performed through the overlays for 40, 80, or 120 s. For each specimen, the composite to be cured, the cured overlay, and the underlay were made out of the same batch of resin composite. All specimens were assigned to three experimental groups on the basis of the resin composite used, and to subgroups on the basis of the overlay thickness and the curing time, resulting in 54 experimental subgroups (n = 5). Forty-five additional specimens, 15 for each material under investigation, were produced and subjected to 40, 80, or 120 s of light curing using a microscope glass as an overlay; they were assigned to 9 control subgroups (n = 5). Three Vicker's hardness (VH) indentations were performed on each specimen. Means and standard deviations were calculated. Data were statistically analyzed using 3-way ANOVA. Within the same material, VH values lower than 55% of control were not considered acceptable. The used material, the overlay thickness, and the curing time significantly influenced VH values. In the ENA group, acceptable hardness values were achieved with 3.5-mm or thinner overlays after 120 or 80 s curing time (VH 41.75 and 39.32, respectively), and with 2-mm overlays after 40 s (VH 54.13). In the SAR group, acceptable hardness values were only achieved with 2-mm-thick overlays after 120 or 80 s curing time (VH 39.81 and 29.78, respectively). In the EST-X group, acceptable hardness values were only achieved with 3-mm or thinner overlays, after 120 or 80 s curing time (VH 36.20 and 36.03, respectively). Curing time, restoration thickness, and overlay material significantly influenced the microhardness of the tested resin composites employed as luting agents. The clinician should carefully keep these factors under control.
Lima, Ana Paula Barbosa; Vitti, Rafael Pino; Amaral, Marina; Neves, Ana Christina Claro; da Silva Concilio, Lais Regiane
2018-04-01
This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values ( P <.05). No statistical differences were found for area of contact points among the groups ( P =.7150). The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.
Legan, J D; Seman, D L; Milkowski, A L; Hirschey, J A; Vandeven, M H
2004-10-01
A central composite response surface design was used to determine the time to growth of Listeria monocytogenes as a function of four continuous variables: added sodium chloride (0.8 to 3.6%), sodium diacetate (0 to 0.2%), potassium lactate syrup (60% [wt/wt]; 0.25 to 9.25%), and finished-product moisture (45.5 to 83.5%) in ready-to-eat cured meat products. The design was repeated for ready-to-eat uncured meat products giving a fifth categorical variable for cure status. Products were stored at 4 degrees C. The results were modeled using a generalized regression approach. All five main effects, six two-factor interactions, and two quadratic terms were statistically significant. The model was used to show the boundary between growth and no-growth conditions at 4 degrees C using contour plots of time to growth. It was validated using independent challenge studies of cured and uncured products. Generally, the model predicted well, particularly for cured products, where it will be useful for establishing conditions that prevent the growth of L. monocytogenes. For uncured products, there was good agreement overall between predicted and observed times to growth, but the model is less thoroughly validated than for cured products. The model should initially only be used for screening of formulations likely to prevent growth of Listeria monocytogenes in uncured products, with recommendations subject to confirmation by challenge studies.
Karateke, Ates; Haliloglu, Berna; Cam, Cetin; Sakalli, Mustafa
2009-02-01
Recently, mid-urethral slings have been commonly used in treatment of patients with stress urinary incontinence (SUI). To investigate tension-free vaginal tape (TVT) and tension-free obturator tape (TVT-O) for surgical treatment of SUI for cure rates (primary endpoint), complications and factors influencing cure rate (secondary endpoints). One-hundred and sixty-four patients were included in the study (n = 81 for TVT, n = 83 for TVT-O). The cure rates, complications, preoperative and postoperative urodynamic evaluation, Q-tip test, the Turkish version of Incontinence Impact Questionnaire (IIQ-7) and Urogenital Distress Inventory (UDI-6) scores were recorded. At three and 12 months, the patients were evaluated regarding outcome measures. The cure rates were similar in TVT and TVT-O groups, 88.9% versus 86.7% respectively. Mean operative time was significantly shorter in TVT-O group (P = 0.001). The cure rate was significantly higher in both groups in patients with urethral hypermobility when compared with those with no hypermobility (P = 0.001). The TVT and TVT-O procedures appear to be equally effective for the treatment of SUI. Also, urethral hypermobility seems to be a factor influencing cure rate of mid-urethral slings.
Morotomi, Takahiko; Hirata-Tsuchiya, Shizu; Washio, Ayako; Kitamura, Chiaki
2016-01-01
To assess the effects of different curing stages of 4-META/MMA-TBB resin on osteoblasts and gingival keratinocytes. The MC3T3-E1 murine pre-osteoblastic cell line and GE-1 murine gingival epithelial cell line were cultured with mixtures of Super-Bond C&B at different curing stages, and the cell viability was assessed. The alkaline phosphatase (ALP) activity of the MC3T3-E1 cells was also assessed. The majority of the MC3T3-E1 cells died and showed no ALP activity when cultured with 4-META/MMA-TBB resin during the initial curing phase (1 min of curing). A later curing phase of the 4-META/MMA-TBB resin (7 min of curing) showed cytotoxicity at day 1, but the toxic effect was temporary and the proliferative capacity and ALP activity in the cells were similar to control cells at day 7. Completely cured 4-META/MMA-TBB resin (after 1 or 12 h of curing) did not affect the cell viability or ALP activity of the MC3T3-E1 cells. In contrast, 4-META/MMA-TBB resin showed no effect on the GE-1 cells at any stage of curing. Although 4-META/MMA-TBB resin during the initial curing phase shows toxic effects on MC3T3-E1 cells, that cytotoxicity is minimal at later curing phases. In contrast, neither the uncured nor cured resins affected the GE-1 cells.
NASA Astrophysics Data System (ADS)
Cantor, Kirk Martin
1998-12-01
Moisture-crosslinkable polyethylene used in the extrusion coating of electrical cable has many advantages over other polymer systems used for crosslinked cable coating. However, one of its major drawbacks is the long cure times required. The purpose of this study was to describe how curing takes place in cable systems using moisture-crosslinkable polyethylene, with an ultimate goal of gaining insight into how cure times might be reduced. Crosslinking was investigated with an emphasis on how the curing reaction proceeds through the coating, using analyses to characterize processing conditions and resulting mechanical and structural properties. In the design of the study, material compounds were varied as were curing conditions. Cable coatings were sectioned by position through the coating thickness and characterized using several techniques. Mechanical, thermal, and structural properties of the polymer coating were measured. A significant finding from the study was that the degree of cure was highest at positions in the coating closest to the conductor. Because this was opposite to what was expected, an investigation into the cause of this finding was pursued. It was found that during cure at elevated temperature, the inside surface of the coating remains at a generally higher temperature than the outside surface. This provides a more favorable cure condition for positions in the coating closest to the conductor. Based on the results of this study, a list of suggested follow-up studies is provided at the end of the dissertation. One proposal for investigating reduced cure times involves providing heat to the interior of the cable during cure.
Clariana, Maria; Guerrero, Luis; Sárraga, Carmen; Garcia-Regueiro, José A
2012-02-01
The effect of high pressure processing at 400 MPa and 900 MPa on the oxidative stability of sliced and vacuum packaged commercial dry-cured ham was determined by analyzing the antioxidant enzyme activities, TBARS levels (thiobarbituric acid reactive substances), vitamin E content and physicochemical characteristics during refrigerated storage for 50 days in different light conditions. In dry-cured ham pressurized at 400 MPa color changes and sensory analyses were also assessed. The high pressure process at 900 MPa produced a decrease in superoxide dismutase (SOD) and glutathione peroxidase (GSHPx) activities and increased vitamin E content. In contrast, pressurization at 400 MPa, increased SOD activity, and showed no effect on vitamin E content and GSHPx activity. In general the physicochemical parameters determined (fat, moisture and collagen) were unaffected by pressurization. Treatment at 400 MPa increased the instrumental color measurement of lightness (L* values, CIELAB). This level of pressure also modified the hardness, chewiness, saltiness and color intensity. These changes of the sensory attributes in dry-cured ham were significant, but small. Copyright © 2011 Elsevier Ltd. All rights reserved.
Okumura, Tetsu; Okanoya, Kazuo; Tani, Jun
2007-01-01
In chronic recording experiments, self-curing dental acrylic resins have been used as a mounting base of electrodes or microdialysis-probes. Since these acrylics do not bond to the bone, screws have been used as anchors. However, in small experimental animals like finches or mouse, their craniums are very fragile and can not successfully hold the anchors. In this report, we propose a new application of light-curing dental resins for mounting base of electrodes or microdialysis probes in chronic experiments. This material allows direct bonding to the cranium. Therefore, anchor screws are not required and surgical field can be reduced considerably. Past experiences show that the bonding effect maintains more than 2 months. Conventional resin's window of time when the materials are pliable and workable is a few minutes. However, the window of working time for these dental adhesives is significantly wider and adjustable. PMID:18997897
Poggio, C; Lombardini, M; Gaviati, S; Chiesa, M
2012-07-01
The current in vitro study evaluated Vickers hardness (VK) and depth of cure (hardness ratio) of six resin composites, polymerized with a light-emitting diode (LED) curing unit by different polymerization modes: Standard 20 s, Standard 40 s, Soft-start 40 s. SIX RESIN COMPOSITES WERE SELECTED FOR THE PRESENT STUDY: three microhybrid (Esthet.X HD, Amaris, Filtek Silorane), two nanohybrid (Grandio, Ceram.X mono) and one nanofilled (Filtek Supreme XT). The VK of the surface was determined with a microhardness tester using a Vickers diamond indenter and a 200 g load applied for 15 seconds. The mean VK and hardness ratio of the specimens were calculated using the formula: hardness ratio = VK of bottom surface / VK of top surface. For all the materials tested and with all the polymerization modes, hardness ratio was higher than the minimum value indicated in literature in order to consider the bottom surface as adequately cured (0.80). Curing time did not affect hardness ratio values for Filtek Silorane, Grandio and Filtek Supreme XT. The effectiveness of cure at the top and bottom surface was not affected by Soft-start polymerization mode.
NASA Astrophysics Data System (ADS)
Burnham, Steven Robert
As much as 50% of ageing-related problems with concrete structures can be attributed to con-struction deficiencies at the time of placement. The most influential time affecting longevity of concrete structures is the curing phase, or commonly the initial 28 days following its placement. A novel advanced atomistic analysis of novel concrete chemistry is presented in this dissertation with the objective to improve concrete structural properties and its longevity. Based on experiments and computational models, this novel concrete chemistry is discussed in two cases: (a) concrete chemistry changes when exposed to low-dose gamma radiation in its early curing stage, thus improving its strength in a shorter period of time then curing for the conventional 28 days; (b) concrete chemistry is controlled by its atomistic components to assure strength is not reduced but that its activation due to long-term exposure to neutron flux in nuclear power plants is negligible. High dose gamma radiation is well documented as a degradation mechanism that decreases concrete's compressive strength; however, the effects of low-dose gamma radiation on the initial curing phase of concrete, having never been studied before, proved its compressive strength increases. Using a 137 Cs source, concrete samples were subjected to gamma radiation during the initial curing phase for seven, 14, and 28 days. The compressive strength after seven days is improved for gamma cured concrete by 24% and after 14 days by 76%. Concrete shows no improvement in compressive strength after 28 days of exposure to gamma radiation, showing that there is a threshold effect. Scanning Electron Microscopy is used to examine the microstructure of low-dose gamma radiation where no damage to its microstructure is found, showing no difference between gamma cured and conventionally cured concrete. Molecular dynamics modeling based on the MOPAC package is used to study how gamma radiation during the curing stage improves compressive strength of concrete. The modeling shows that when radiolysis occurs in freshly mixed concrete, the reactivity between key molecules responsible for bonding between cement and aggregate is enhanced due to improved reactivity at the molecular level. A new method is developed that successfully controls a concrete chemistry at the atomistic level by assuring its long-term exposure to neutron flux in nuclear power plants will not activate the dome wall to the level of low-level radioactive waste. This methodology is established to detect and select the level of trace elemental composition in concrete based on a low-flux neutron activation analysis (NAA). By carefully selecting aggregates that do not contain certain elements that activate to high concentrations after decades of concrete exposure to neutron flux, the end of life for concrete is improved by declassifying it as low-level radioactive waste. Directly, it improves economy of commissioning nuclear power plants to be built in near future and reducing important quantities of waste to be disposed at high costs.
Sociedad Española de Patología Digestiva
2014-01-01
The advent of direct-action antivirals telaprevir and boceprevir has entailed a radical change in the healing possibilities for patients with hepatitis C. This change has coincided with the emergence of highly robust evidence on the benefits of cure as regards increased overall survival, mainly brought about by a reduction in liver-related events in the long run. Therefore, a finite-in-time treatment is available that achieves very notable results both short- and long-term. Triple therapy, consisting of the association of one of these novel drugs with the previously standard regimen of pegylated interferon and ribavirin, has come in the setting of a financial crisis, which has led to restrict its use primarily for patients with advanced fibrosis. These patients--who need a cure the most--are those with the lowest healing rates and the commonest, most severe side effects. The time has then come to shift the aim point towards patients with less severe fibrosis, better cure rates, and fewer side effects where therapeutic intervention may prevent the development of significant liver disease. Despite record-time approval by the European Medicines Agency, various barriers--mainly at the Autonomic regional level--have delayed access to these therapies by our patients, thus giving rise to inequality situations. New oral therapies are now on the near horizon that will increase the numbers of patients eligible for treatment with fewer side effects and a higher cure rate. We hope that the lesson is learned and no such situation will be repeated. An Integrated National Action Plan Against Hepatitis C would be an essential tool for countering this disease.
A cellular automata model for avascular solid tumor growth under the effect of therapy
NASA Astrophysics Data System (ADS)
Reis, E. A.; Santos, L. B. L.; Pinho, S. T. R.
2009-04-01
Tumor growth has long been a target of investigation within the context of mathematical and computer modeling. The objective of this study is to propose and analyze a two-dimensional stochastic cellular automata model to describe avascular solid tumor growth, taking into account both the competition between cancer cells and normal cells for nutrients and/or space and a time-dependent proliferation of cancer cells. Gompertzian growth, characteristic of some tumors, is described and some of the features of the time-spatial pattern of solid tumors, such as compact morphology with irregular borders, are captured. The parameter space is studied in order to analyze the occurrence of necrosis and the response to therapy. Our findings suggest that transitions exist between necrotic and non-necrotic phases (no-therapy cases), and between the states of cure and non-cure (therapy cases). To analyze cure, the control and order parameters are, respectively, the highest probability of cancer cell proliferation and the probability of the therapeutic effect on cancer cells. With respect to patterns, it is possible to observe the inner necrotic core and the effect of the therapy destroying the tumor from its outer borders inwards.
Cao, Li; Wang, Fan
2014-05-01
To compare the efficacy differences between needle-knife therapy and acupuncture-cupping for treatment of cervical spondylosis (CS) of cervical type. Sixty cases of CS were randomly divided into a needle-knife group (30 cases) and an acupuncture-cupping group (30 cases). The needle-knife therapy was applied at points among superior nuchal line of occipital bone, bilateral neck muscle, neck centerline, trapezius and medial border scapula for only once. In the acupuncture-cupping group, acupuncture was applied at Fengchi (GB 20), Fengfu (GV 16), Tianzhu (BL 10), Dazhui (GV 14), Jianjing (GB 21), Jiaji (Ex-B2, from C4 to C6), Houxi (SI 3) and Ashi point, followed by cupping on local skin, once every other day for totally six times. The score of neck stiffness and visual analogue scale (VAS) were observed before and after treatment, in follow-up of 1, 3 and 6 months after treatment in the two groups, and the efficacy was compared. In the needle-knife group, 9 cases were cured, 12 cases were markedly effective, 8 cases were effective and 1 case was failed; the total effective rate was 96.7% (29/30) and the cured and markedly effective rate was 70.0% (21/30). In the acupuncture-cupping group, 8 cases were cured, 9 cases were markedly effective, 11 cases were effective and 2 cases were failed; the total effective rate was 93.3% (28/30) and the cured and markedly effective rate was 56.7% (17/30). The difference of total effective rate in the two groups was not statistically significant (P > 0.05), but the cured and markedly effective rate of needle-knife group was significantly superior to that of acupuncture-cupping group (P < 0.05). The needle-knife therapy was significantly superior to acupuncture-cupping on improvement of neck stiffness in the follow-up of 1, 3, 6 months after treatment (P < 0.05, P < 0.001); both treatments were effective on relief of neck pain, but the needle-knife group had better effects in the follow-up of 3 and 6 months after treatment compared with acupuncture-cupping group (both P < 0.01). The needle-knife therapy has better effects on neck stiffness and pain relief than acupuncture-cupping, and it is more treatment time saving.
NASA Astrophysics Data System (ADS)
Smith, Ryan Scott
As the gate density increases in microelectronic devices, the interconnect delay or RC response also increases and has become the limiting delay to faster devices. In order to decrease the RC time delay, a new metallization scheme has been chosen by the semiconductor industry. Copper has replaced aluminum as the metal lines and new low-k dielectric materials are being developed to replace silicon dioxide. A promising low-k material is porous organosilicate glass or p-OSG. The p-OSG film is a hybrid material where the silicon dioxide backbone is terminated with methyl or hydrogen, reducing the dielectric constant and creating mechanically weak films that are prone to fracture. A few methods of improving the mechanical properties of p-OSG films have been attempted-- exposing the film to hydrogen plasma, electron beam curing, and ultra-violet light curing. Hydrogen plasma and electron-beam curing suffer from a lack of specificity and can cause charging damage to the gates. Therefore, ultra-violet light curing (UV curing) is preferable. The effect of UV curing on an ultra-low-k, k~2.5, p-OSG film is studied in this dissertation. Changes in the molecular structure were measured with Fourier Transform Infrared Spectroscopy and X-ray Photoelectron Spectroscopy. The evolution of the molecular structure with UV curing was correlated with material and fracture properties. The material properties were film shrinkage, densification, and an increase in dielectric constant. From the changes in molecular structure and material properties, a set of condensation reactions with UV light are predicted. The connectivity of the film increases with the condensation reactions and, therefore, the fracture toughness should also increase. The effect of UV curing on the critical and sub-critical fracture toughness was also studied. The critical fracture toughness was measured at four different mode-mixes-- zero, 15°, 32°, and 42°. It was found that the critical fracture toughness increases with UV exposure for all mode mixes. The sub-critical fracture toughness was measured in Mode I and found to be insensitive to UV cure. A simple reaction rate model is used to explain the difference in critical and sub-critical fracture toughness.
Light-attenuating effect of dentin on the polymerization of light-activated restorative resins.
Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Ban, Seiji; Takahashi, Hideo
2004-12-01
The light-attenuating effect of dentin on the mechanical properties of light-activated composite resins was evaluated using a simple experimental filter. The filter was designed to simulate the light transmittance and light diffusion characteristics of 1.0-mm thick dentin. The depth of cure, surface hardness, and flexural strength for 13 shades of three light-activated restorative resins were examined. These resins were cured either using direct irradiation with a light source, or indirect irradiation through the filter. The attenuation of light intensity by 1.0-mm thick dentin reached 85-90% in the 400-550 nm wavelength region. For all materials, the values of depth of cure, surface hardness on the top and bottom surfaces, and flexural strength of specimens irradiated indirectly through the simulated 1.0-mm thick dentin filter decreased by 37-60%, 16-55%, 50-83%, and 44-82% in comparison with those by direct irradiation, respectively. Recovery from mechanical properties' reduction was achieved when materials were irradiated 1.5-4 times longer than the standard irradiation time.
Rubio-Celorio, Marc; Garcia-Gil, Núria; Gou, Pere; Arnau, Jacint; Fulladosa, Elena
2015-02-01
Dielectric Time Domain Reflectometry (TDR) is a useful technique for the characterization and classification of dry-cured ham according to its composition. However, changes in the behavior of dielectric properties may occur depending on environmental factors and processing. The effect of temperature, high pressure (HP) and freezing/thawing of dry-cured ham slices on the obtained TDR curves and on the predictions of salt and water contents when using previously developed predictive models, was evaluated in three independent experiments. The results showed that at temperatures below 20 °C there is an increase of the predicted salt content error, being more important in samples with higher water content. HP treatment caused a decrease of the reflected signal intensity due to the major mobility of available ions promoting an increase of the predicted salt content. Freezing/thawing treatment caused an increase of the reflected signal intensity due to the microstructural damages and the loss of water and ions, promoting a decrease of the predicted salt content.
McMurtrie, K E; Kerth, C R; Bratcher, C L; Curtis, P A; Smith, B
2012-03-01
Beef inside round roasts (n=144) were cut from rounds obtained from both forage-finished cattle (n=72) and commercially-sourced beef (n=72). Roasts were portioned to weigh 0.45-0.68kg each. Each roast was then randomly assigned one of the following treatments: control, injected-no cure, or injected-cured. Additionally, roasts were assigned a serving temperature (hot or cold) and storage treatments (0d or 28d post cooking). Roasts from forage-fed beef had a more red interior color and higher shear values, and also retained more brine than commercially-sourced beef (P<0.05). Curing roasts improved TBARS values in roasts served hot and significantly reduced sensory warmed-over and grassy flavors (P<0.05). Marinating forage-finished beef roasts significantly improves tenderness and flavor characteristics. Copyright © 2011 Elsevier Ltd. All rights reserved.
Evaluating the bakeout effectiveness of RTV-S691 silicone adhesive by measuring outgassing rate
NASA Astrophysics Data System (ADS)
Miyazaki, Eiji; Miura, Yuka; Numata, Osamu; Yamanaka, Riyo; Baba, Susumu; Ishizawa, Junichiro; Kimoto, Yugo; Tamura, Takashi
2014-09-01
Outgassing rate measurements are basically performed for fresh materials, e.g. just cured adhesives, paints, etc. and reveal a lot about how the material can behave as a contamination source. It is also important to determine the bakeout process sufficiently. In the present study, a typical silicone adhesive for use in space, RTV S-691, Wacker Chemie, was selected for the measurement. Two cured specimens, 40 × 40 mm in size, were applied for several isothermal tests under identical conditions: a specimen at 125 degrees C for 144 hours with CQCM at -193 degrees C to measure TML. Consequently, it was determined that the TML and TML rate could be reduced by bakeout as expected. It also emerged that a longer bakeout, i.e. a longer cumulative bakeout time, for the material would reduce the TML and TML rate more effectively. The results suggest that bakeout mainly affects the behavior in the "low-rate" phase, whereby the TML rate curve can be divided into two phases. The elapsed time for a specimen can also be considered the cumulative test time. Based on the cumulative elapsed time, the TML rate curve is replotted and a correlation emerges between the cumulative bakeout time and TML rate. The first measurement data of TML and the TML rate could be affected by the stored time from cure, which might result from the change in unreacted substances declining as the stored time elapsed.
7 CFR 1463.106 - Base quota levels for eligible tobacco producers.
Code of Federal Regulations, 2012 CFR
2012-01-01
...)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm's average... (35-36)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 6 Multiply the sum from Step 5 times the farm... (35-36)—.94264 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm...
7 CFR 1463.106 - Base quota levels for eligible tobacco producers.
Code of Federal Regulations, 2013 CFR
2013-01-01
...)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm's average... (35-36)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 6 Multiply the sum from Step 5 times the farm... (35-36)—.94264 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm...
7 CFR 1463.106 - Base quota levels for eligible tobacco producers.
Code of Federal Regulations, 2014 CFR
2014-01-01
...)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm's average... (35-36)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 6 Multiply the sum from Step 5 times the farm... (35-36)—.94264 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm...
7 CFR 1463.106 - Base quota levels for eligible tobacco producers.
Code of Federal Regulations, 2011 CFR
2011-01-01
...)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm's average... (35-36)—.952381 (iv) Virginia Sun-cured (type 37) 1.0000 6 Multiply the sum from Step 5 times the farm... (35-36)—.94264 (iv) Virginia Sun-cured (type 37) 1.0000 3 Multiply the sum from Step 2 times the farm...
[Effect of Radii barrier sleeves on cure depth of composite resin].
Wang, Binping; DU, Yongxiu
2009-01-01
To explore the effect of Radii barrier sleeves on the cure depth of composite resin. Cylinder mold was prepared, and the resin was filled strictly into the mold. The surface was flattened and then cured with plastic engraver's knife.The depth of composite resin which was cured by QHL75TM with or without Radii barrier sleeves was compared. The cure depth of composite resin which were cured by QHL75TM with or without Radii barrier sleeves of photo-curing machine was 4.38 mm and 4.27 mm respectively,with no statistical difference. The cure depth of composite resin is not influenced by Radii barrier sleeves under the same light condition.
Assessment of Salmonella survival in dry-cured Italian salami.
Bonardi, S; Bruini, I; Bolzoni, L; Cozzolino, P; Pierantoni, M; Brindani, F; Bellotti, P; Renzi, M; Pongolini, S
2017-12-04
The inactivation of Salmonella during curing of Italian traditional pork salami was investigated. A total of 150 batches of ground raw meat (GRM) used for salami manufacturing by four producers were tested for Salmonella by real-time PCR followed by ISO 6579 cultural confirmation and MPN enumeration. Salami produced with Salmonella positive GRMs were re-tested at the end of their curing period. Aw, pH and NaCl content were also measured. Detection of Salmonella was performed testing both 25 and 50g of the samples. By Real-Time PCR 37% of the GRMs resulted positive, but cultural detection of Salmonella was obtained in 14% of the samples only. Salmonella enumeration ranged from 31 MPN/g to <1.3 MPN/g. The difference between testing 50g and 25g of the samples was statistically significant (p value≤0.01). In particular, ISO-50g detected Salmonella in 100% of all positive samples, vs. 62% of ISO-25g. Salami made of the contaminated GRMs were 29% Salmonella-positive, as most batches of salami produced with Salmonella-positive GRMs resulted negative after regular curing (20-48days). Overall, 13% of salami produced with Salmonella-contaminated GRMs were positive. They belonged to six batches, which turned out negative after prolonged curing ranging between 49 and 86days. Salmonella enumeration in salami ranged from 8.7 MPN/g to <1.3 MPN/g. Unlike GRMs, no significant difference was observed between the ISO-50g and the ISO-25g in detecting Salmonella in cured salami (p value: >0.05). The most common Salmonella serovars in GRMs were Derby (52%), Typhimurium monophasic variant 4, (Barbuti et al., 1993), 12:i:- (19%) and Stanley (10%). Salmonella Derby (56%), London, Branderup, Panama (13%, respectively) and Goldcoast (6%) were most frequent in cured salami. The study showed negative correlation between real-time CT values and cultural confirmation of Salmonella, as well as the importance of sample size for Salmonella detection. Among considered factors with possible effect on the occurrence of Salmonella in salami, statistical analysis revealed a role for aw in salami and for Salmonella load in GRMs, while pH and NaCl content did not significantly affect the probability of finding Salmonella in dry-cured salami in the context of this study. In particular the lower aw values due to longer curing were associated with lower Salmonella presence in traditional dry-cured salami. Copyright © 2017 Elsevier B.V. All rights reserved.
Insufficient cure under the condition of high irradiance and short irradiation time.
Feng, Li; Carvalho, Ricardo; Suh, Byoung I
2009-03-01
To investigate if and why a plasma arc curing (PAC) light tends to undercure methacrylate-based resins or resin composites. Model dimethacrylate resins, commercial dental adhesives, and commercial resin composites were cured using a PAC light and a halogen light with the similar radiant exposures but different combinations of irradiance and irradiation time. The degree of double bond conversion (DC) was measured with FTIR spectroscopy and analyzed as a function of radiant exposure. The PAC light produced a lower DC than the halogen light for the model resin with the lowest viscosity and for three of the four adhesives. With a high irradiance, the PAC light could cure three of the four composites as thoroughly as its halogen counterpart. When the irradiance was reduced, however, three composites yielded a lower DC. Insufficient cure by PAC lights or any curing lights with very high irradiance is likely to happen when too short an irradiation time is used. It is because under higher irradiance, the lifetime of free radicals is shorter.
Development of processing diagrams for polymeric die attach adhesives
NASA Astrophysics Data System (ADS)
Hsiung, Jen-Chou
With a processing diagram, one can reduce the effort required to customize curing process conditions for polymeric die attach adhesives. Polymeric die attach adhesives are often cured per the manufacturer's recommendations during initial screening evaluations. In most cases, the recommended cure schedules have to be modified so as to fit differences in process equipment. Unfortunately, the modified cure schedule is usually determined by a trial-and-error method. An aim of our experiments is to understand the curing process of a wide range of polymeric die attach adhesives (conventional, fast, and snap cure adhesives) and to construct a processing diagram, i.e., "Bondability Diagram", so as to define the processing window. Such diagrams should be helpful in determining both the time and cure temperature required to produce high quality bonds. The bondability diagram can be constructed based on fundamental understandings of the phenomena involved in the curing process using a wide variety of tools. Differential Scanning Calorimetry (DSC) is utilized to study the cure kinetics and the extent of reaction. Dynamic Mechanical Analysis (DMA) is used to determine gelation times and melt viscosity under a shear mode. A modified Rheovibron is employed to perform cure characterizations under a tensile mode so that cure stresses could be determined. Thermogravimetric Analysis (TGA) is used to evaluate the outgassing phenomena. Optical Microscopy (OM) is used to detect voids. Results indicate that the cure behaviors of conventional, fast, and snap cure adhesives are different in several respects. The combination of DSC, DMA, TGA, OM, and lap shear test leads to a frame work of developing the bondability diagram concept. The bondability diagram concept provides a foundation for an understanding of the recommended cure schedule and allows one to design their own cure schedule.
NASA Astrophysics Data System (ADS)
Chankrachang, M.; Limphirat, W.; Yongyingsakthavorn, P.; Nontakaew, U.; Tohsan, A.
2017-09-01
A study of sulfidic linkages formed in natural rubber (NR) latex medical gloves by using X-ray Absorption Near Edge Structure (XANES) is presented in this paper. The NR latex compound was prepared by using prevulcanization method, that is, it was prevulcanized at room temperature for 24 hrs before utilization. After the 24 hrs of prevulcanization, the latex film samples were obtained by dipping process. The dipped films were subjected to vulcanize at 110°C for 5 to 25 min. It was observed that after the compound was prevulcanized for 24 hrs, polysulfidic linkages were mainly formed in the sample. It was however found that after curing at 110°C for 5-25 min, the polysulfidic linkages are tended to change into disulfide linkages. Especially, in the case of 25 minutes cured sample, disulfide linkages are found to be the main linkages. In term of tensile strength, it was observed that when cure time increased from 5 - 10 min, tensile strengths were also increased. But when the cure time of the film is 25 minutes, tensile strength was slightly dropped. The dropped of tensile strength when cure time is longer than 10 minutes can be ascribed to a degradation of polysulfidic and disulfidic linkages during curing. Therefore, by using XANES analysis, it was found to be very useful to understand the cure characteristic, thus it can be very helpful to optimize cure time and tensile properties of the product.
Giuliodori, M J; Magnasco, M; Magnasco, R P; Lacau-Mengido, I M; de la Sota, R L
2017-05-01
The objectives of this study were to assess the association of a 4-point scale of vaginal discharge score (VDS) with time to pregnancy to define criteria for a practical case of purulent vaginal discharge (PVD) in dairy cows, to test the risk factors for PVD, and, finally, the effect of a dose of PGF 2α on cure and reproductive performance. In experiment 1, grazing Holstein cows (n = 2,414) had their vaginal discharge scored at ∼32 d in milk (DIM) on a 4-point scale, the effect of VDS on the hazard of pregnancy by 300 DIM was then assessed to derive a case definition of PVD. Risk factors for PVD and self-cure were also assessed. In experiment 2, grazing Holstein cows (n = 6,326) from 5 herds were checked for PVD at ∼30 DIM. Cows with PVD were assigned to receive one dose of 500 μg of PGF 2α analog (Cloprostenol; Ciclase, Syntex SA, Buenos Aires, Argentina) per cow (odd ear tag number) or to remain untreated (even tag number). Cure was declared if cows presented clear normal vaginal discharge (VDS-0) at visit 2 (∼62 DIM). Data were analyzed with Cox's regression and mixed logistic models. In experiment 1, cows with VDS ≥1 had lower hazard of pregnancy and longer calving to pregnancy interval than cows with VDS-0. This finding was not affected by the time at which the diagnosis was performed. Therefore, a cow ≥21 DIM and having VDS ≥1 was used to define a case of PVD. The odds of PVD were greater in primiparous cows compared with multiparous, in cows with abnormal calving compared with those with normal calving, and in those losing BCS peripartum. In experiment 2, PGF 2α treatment tended to slightly increase the hazard of pregnancy (adjusted hazard ratio = 1.13). Conversely, PGF 2α had no effect on the odds of cure of PVD [adjusted odds ratio (AOR) = 1.19], pregnancy at first service (AOR = 1.03), or pregnancy by 100 DIM (AOR = 0.89) or 200 DIM (AOR = 1.27). In conclusion, cows with VDS ≥1 can be considered to have PVD because of their lower hazard of pregnancy and longer calving to pregnancy interval (up to 48 d). Important risk factors are parity, calving, and body condition score loss peripartum. Optimal time of diagnosis is ≥28 to 35 DIM because cows experience a high self-cure rate. Self-cure is also affected by parity, prepartum BCS, and VDS. Finally, as treatment with one dose of PGF 2α had a small effect on the hazard of pregnancy and no effect on clinical cure, its therapeutic use in grazing dairy cows with PVD is not recommended. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mu, Quanyi; Dunn, Conner K.; Wang, Lei; Dunn, Martin L.; Qi, H. Jerry; Wang, Tiejun
2017-04-01
Recent developments in soft materials and 3D printing are promoting the rapid development of novel technologies and concepts, such as 4D printing and soft machines, that in turn require new methods for fabricating conductive materials. Despite the ubiquity of silver nanoparticles (NPs) in the conducting electrodes of printed electronic devices, their potential use in stretchable conductors has not been fully explored in 4D printing and soft machines. This paper studies the effect of thermal cure conditions on conductivity and electro-mechanical behaviors of silver ink by the direct ink write (DIW) printing approach. We found that the electro-mechanical properties of silver wires can be tailored by controlling cure time and cure temperature to achieve conductivity as well as stretchability. For the silver NP ink we used in the experiments, silver wires cured at 80 °C for 10-30 min have conductivity >1% bulk silver, Young’s modulus <100 MPa, yield strain ˜9%, and can retain conductivity up to 300% strain. In addition, under stress controlled cyclic loading/unloading conditions, the resistance of these wires is only about 1.3 times the initial value after the 100th repeat cycle (7.6% maximum strain in the first cycle). Silver wires cured at 120 °C for 10-20 min are more sensitive to strain and have a yield strain of around 6%. These properties indicate that the silver ink can be used to fabricate stretchable electrodes and flex sensors. Using the DIW fabrication method, we printed silver ink patterns on the surface of 3D printed polymer parts, with the future goal of constructing fully 3D printed arbitrarily formed soft and stretchable devices and of applying them to 4D printing. We demonstrated a fully printed functional soft-matter sensor and a circuit element that can be stretched by as much as 45%.
Katsumasa Miyake; Bunichiro Tomita; Chung-Yun Hse; George E. Myers
1989-01-01
A new curing system for urea-formaldehyde (UF) resins was investigated using poly(methacryloyl hydrazide) as the curing reagent. Results were as follows: 1) Gel time and the water-soluble part of cured resins were determined as function of pH and molar ratio [hydrazide group/(free formaldehyde+methylol group)]. It was found that the reaction in this system proceeds for...
Analysing malaria drug trials on a per-individual or per-clone basis: a comparison of methods.
Jaki, Thomas; Parry, Alice; Winter, Katherine; Hastings, Ian
2013-07-30
There are a variety of methods used to estimate the effectiveness of antimalarial drugs in clinical trials, invariably on a per-person basis. A person, however, may have more than one malaria infection present at the time of treatment. We evaluate currently used methods for analysing malaria trials on a per-individual basis and introduce a novel method to estimate the cure rate on a per-infection (clone) basis. We used simulated and real data to highlight the differences of the various methods. We give special attention to classifying outcomes as cured, recrudescent (infections that never fully cleared) or ambiguous on the basis of genetic markers at three loci. To estimate cure rates on a per-clone basis, we used the genetic information within an individual before treatment to determine the number of clones present. We used the genetic information obtained at the time of treatment failure to classify clones as recrudescence or new infections. On the per-individual level, we find that the most accurate methods of classification label an individual as newly infected if all alleles are different at the beginning and at the time of failure and as a recrudescence if all or some alleles were the same. The most appropriate analysis method is survival analysis or alternatively for complete data/per-protocol analysis a proportion estimate that treats new infections as successes. We show that the analysis of drug effectiveness on a per-clone basis estimates the cure rate accurately and allows more detailed evaluation of the performance of the treatment. Copyright © 2012 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
El Labban, A.; Mousseau, P.; Bailleul, J. L.; Deterre, R.
2007-04-01
Although numerical simulation has proved to be a useful tool to predict the rubber vulcanization process, few applications in the process control have been reported. Because the end-use rubber properties depend on the state of cure distribution in the parts thickness, the prediction of the optimal distribution remains a challenge for the rubber industry. The analysis of the vulcanization process requires the determination of the thermal behavior of the material and the cure kinetics. A nonisothermal vulcanization model with nonisothermal induction time is used in this numerical study. Numerical results are obtained for natural rubber (NR) thick-section part curing. A controlled gradient of the state of cure in the part thickness is obtained by a curing process that consists not only in mold heating phase, but also a forced convection mold cooling phase in order to stop the vulcanization process and to control the vulcanization distribution. The mold design that allows this control is described. In the heating phase, the state of cure is mainly controlled by the chemical kinetics (the induction time), but in the cooling phase, it is the heat diffusion that controls the state of cure distribution. A comparison among different cooling conditions is shown and a good state of cure gradient control is obtained.
NASA Technical Reports Server (NTRS)
Hou, Tan-Hung
2014-01-01
For the fabrication of resin matrix fiber reinforced composite laminates, a workable cure cycle (i.e., temperature and pressure profiles as a function of processing time) is needed and is critical for achieving void-free laminate consolidation. Design of such a cure cycle is not trivial, especially when dealing with reactive matrix resins. An empirical "trial and error" approach has been used as common practice in the composite industry. Such an approach is not only costly, but also ineffective at establishing the optimal processing conditions for a specific resin/fiber composite system. In this report, a rational "processing science" based approach is established, and a universal cure cycle design protocol is proposed. Following this protocol, a workable and optimal cure cycle can be readily and rationally designed for most reactive resin systems in a cost effective way. This design protocol has been validated through experimental studies of several reactive polyimide composites for a wide spectrum of usage that has been documented in the previous publications.
Microhardness of resin composites polymerized by plasma arc or conventional visible light curing.
Park, S Ho; Krejci, I; Lutz, F
2002-01-01
This study evaluated the effectiveness of the plasma arc curing (PAC) unit for composite curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing units, the microhardness of two composites (Z100 and Tetric Ceram) that had been light cured by the PAC or QTH units, were compared according to the depth from the composite surface. In addition, linear polymerization shrinkage was compared using a custom-made linometer between composites which were light cured by PAC or QTH units. Measuring polymerization shrinkage for two resin composites (Z100 and Tetric Ceram) was performed after polymerization with either QTH or PAC units. In the case of curing with the PAC unit, the composite was light cured with Apollo 95E for two (Group 1), three (Group 2), six (Group 3) or 2 x 6 (Group 4) seconds. For light curing with the QTH unit, the composite was light cured for 60 seconds with Optilux 500 (Group 5). The linear polymerization shrinkage of composites was determined in the linometer. Two resin composites were used to measure microhardness. Two-mm thick samples were light cured for three seconds (Group 1), six seconds (Group 2) or 12 (2 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). For 3 mm thick samples, the composites were light cured for six seconds (Group 1), 12 (2 x 6) seconds (Group 2) or 18 (3 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). Twenty samples were assigned to each group. The microhardness of the upper and lower surfaces was measured with a Vickers hardness-measuring instrument under load. The difference in microhardness between the upper and lower surfaces in each group was analyzed by paired t-test. For the upper or lower surfaces, one-way ANOVA with Tukey was used. For Tetric Ceram, the amount of polymerization shrinkage was lower when cured with the Apollo 95E for two or three seconds than when cured for six and 12 (2 x 6) seconds, or for 60 seconds with Optilux 500 (p<0.05). For Z100, the amount of linear polymerization shrinkage was lower when cured with the Apollo 95E for two, three and six seconds than for 12 (2 x 6) seconds with Apollo 95E or for 60 seconds with the Optilux 500 (p<0.05). The results of the microhardness test indicated that there was no statistically significant difference in microhardness between groups for the upper surface. However, for the lower surface, when the composites were light cured with Apollo 95E for three seconds as recommended by the manufacturer, microhardness of the lower surface was usually lower than that of the upper surface and did not cure sufficiently. Conclusively, when compared with conventional QTH unit, the PAC unit, Apollo 95E did not properly cure the lower composite surface when the layer thickness exceeded 2 mm. In addition, three seconds of curing time, which the manufacturer recommended, was insufficient for optimal curing of composites.
Properties of ambient cured blended alkali activated cement concrete
NASA Astrophysics Data System (ADS)
Talha Junaid, M.
2017-11-01
This paper presents results of the development and strength properties of ambient-cured alkali activated geopolymer concrete (GPC). The study looks at the strength properties, such as compressive strength, splitting tensile strength, and elastic modulus of such concretes and its dependency on various parameters. The parameters studied in this work are the type and proportions of pre-cursor materials, type of activator and their respective ratios and the curing time. Two types of pre-cursor material; low calcium fly ash (FA) and ground granulated blast furnace slag (GGBFS) were activated using different proportions of sodium silicate and sodium hydroxide solutions. The results indicate that ambient cured geopolymer concrete can be manufactured to match strength properties of ordinary Portland cement concrete (OPC). The strength properties of GPC are dependent on the type and ratio of activator and the proportion of GGBFS used. Increasing the percentage of GGBFS increased the compressive and tensile strengths, while reducing the setting time of the mix. The effect of GGBFS on strength was more pronounced in mixes that contained sodium silicate as activator solution. Unlike OPC, ambient-cured GPC containing sodium silicate gain most of their strength in the first 7 days and there is no change in strength thereafter. However, GPC mixes not containing sodium silicate only achieve a fraction of their strength at 7 days and extended curing is required for such concretes to gain full strength. The results also indicate that the elastic modulus values of GPC mixes without sodium silicate are comparable to OPC while mixes with sodium silicate have elastic modulus values much lower than ordinary concrete.
DSC and curing kinetics study of epoxy grouting diluted with furfural -acetone slurry
NASA Astrophysics Data System (ADS)
Yin, H.; Sun, D. W.; Li, B.; Liu, Y. T.; Ran, Q. P.; Liu, J. P.
2016-07-01
The use of furfural-acetone slurry as active diluents of Bisphenol-A epoxy resin (DGEBA) groutings has been studied by dynamic and non-isothermal DSC for the first time. Curing kinetics study was investigated by non-isothermal differential scanning calorimetries at different heating rates. Activation enery (Ea) was calculated based on Kissinger and Ozawa Methods, and the results showed that Ea increased from 58.87 to 71.13KJ/mol after the diluents were added. The furfural-acetone epoxy matrix could cure completely at the theoretical curing temperature of 365.8K and the curing time of 139mins, which were determined by the kinetic model parameters.
Measurement of the degree of cure in epoxies with ultrasonic velocity
NASA Technical Reports Server (NTRS)
Winfree, W. P.; Parker, F. R.
1986-01-01
The use of ultrasonic longitudinal velocity values to measure the degree of cure (defined for an epoxide system as the concentration of epoxide/amine bonds divided by the initial epoxide concentration) in epoxy resins is investigated. The experimental setup used to measure the changes in longitudinal velocity with time is described, together with the technique used to calculate the degree of cure from the acoustic data, using the principle of additive module. Measurements were done with diglycidyl ether of bisphenol A epoxy resin cured with an amine adduct agent. Good qualitative agreement was shown between the time dependence of the acoustically measured degree of cure and the predicted rate of reaction.
Dsouza, Roshan; Subhash, Hrebesh; Neuhaus, Kai; Kantamneni, Ramakrishna; McNamara, Paul M; Hogan, Josh; Wilson, Carol; Leahy, Martin
2016-01-01
Monitoring the curing kinetics of light-activated resin is a key area of research. These resins are used in restorative applications and particularly in dental applications. They can undergo volumetric shrinkage due to poor control of the depth dependent curing process, modulated by the intensity and duration of the curing light source. This often results in the formation of marginal gaps, causing pain and damage to the restoration site. In this study, we demonstrate the capabilities of a correlation method applied using a multiple references optical coherence tomography (MR-OCT) architecture to monitor the curing of the resin. A MR-OCT system is used in this study to monitor the curing of the resin. The system operates at the center wavelength of 1310 nm with an A-scan rate of 1200 A-scans per second. The axial and lateral resolution of the system is ∼13 μm and ∼27 μm. The method to determine the intensity correlation between adjacent B-frames is based on the Pearson correlation coefficient for a region of interest. Calculating the correlation coefficient for multiple B-frames related to the first B-frame at regular spaced time points, shows for a noncured resin a reduction of the correlation coefficient over time due to Brownian motion. The time constant of the reduction of the correlation value is a measure for the progress of the polymerization during LED light irradiation of the resin. The proposed approach is potentially a low-cost, powerful and unique optical imaging modality for measuring the curing behavior of dental resin and other resins, coatings, and adhesives in medical and industrial applications. To demonstrate the proposed method to monitor the curing process, a light-activated resin composite from GRADIA DIRECT ANTERIOR (GC Corporation, Japan) is studied. The curing time of resin was measured and monitored as a function of depth. The correlation coefficient method is highly sensitive to Brownian motion. The process of curing results in a change in intensity as measured by the MR-OCT signal and hence can be monitored using this method. These results show that MR-OCT has the potential to measure the curing time and monitor the curing process as a function of depth. Moreover, MR-OCT as a product has potential to be compact, low-cost and to fit into a smartphone. Using such a device for monitoring the curing of the resin will be suitable for dentists in stationary and mobile clinical settings. © 2015 Wiley Periodicals, Inc.
PLOTNIKOV, A; FISHMAN, D; TICHLER, T; KORENSTEIN, R; KEISARI, Y
2004-01-01
Low electric field cancer treatment − enhanced chemotherapy (LEFCT-EC) is a new anticancer treatment which utilizes a combination of chemotherapeutic agents and a low electric field. We investigated the antitumour effectiveness of this technique in a model of murine colon carcinoma (CT-26). The low electric field was applied to ∼65 mm3 intracutaneous tumours after intratumoral injection of 5FU, bleomycin or BCNU. We observed significant tumour size reduction and a prolongation of survival time. The complete cure of a significant fraction of animals treated by LEFCT-EC with 5FU (33%), bleomycin (51%) or BCNU (83%) was observed. Mice cured by LEFCT-EC developed resistance to a tumour challenge and their splenocytes had antitumour activity in vivo. Our results suggest that LEFCT-EC is an effective method for treatment of solid tumours. PMID:15544616
Plotnikov, A; Fishman, D; Tichler, T; Korenstein, R; Keisari, Y
2004-12-01
Low electric field cancer treatment-enhanced chemotherapy (LEFCT-EC) is a new anticancer treatment which utilizes a combination of chemotherapeutic agents and a low electric field. We investigated the antitumour effectiveness of this technique in a model of murine colon carcinoma (CT-26). The low electric field was applied to approximately 65 mm3 intracutaneous tumours after intratumoral injection of 5FU, bleomycin or BCNU. We observed significant tumour size reduction and a prolongation of survival time. The complete cure of a significant fraction of animals treated by LEFCT-EC with 5FU (33%), bleomycin (51%) or BCNU (83%) was observed. Mice cured by LEFCT-EC developed resistance to a tumour challenge and their splenocytes had antitumour activity in vivo. Our results suggest that LEFCT-EC is an effective method for treatment of solid tumours.
The Effect of Curing Temperature on the Fracture Toughness of Fiberglass Epoxy Composites
NASA Astrophysics Data System (ADS)
Ryan, Thomas J.
The curing reaction in a thermoset polymer matrix composite is often accelerated by the addition of heat in an oven or autoclave. The heat added increases the rate of the polymerization reaction and cross-linking in the material. The cure cycle used (temperature, pressure and time) can therefore alter the final material properties. This research focuses on how the curing temperature (250, 275, 300 °F) affects the yield strength and the mode I interlaminar fracture toughness, GI, of a unidirectional S-2 glass epoxy composite. The test method that was used for the tension test was ASTM D3039 and the test method for the mode I interlaminar fracture toughness, the double cantilever beam (DCB) test, was ASTM D5528. The DCB specimens were fabricated with a non-adhesive insert at the midplane of the composite that serves as the initiatior of the delamination. Opening forces were then applied to the specimen, causing the crack propagation. The results show that increasing the cure temperature by 50 °F increased the tensile strength by 10% (86.54 - 94.73 ksi) and decreased the fracture toughness 20% (506.23 - 381.31 J/m 2). Thus, the curing temperature can cause a trade-off between these two properties, which means that the curing cycle will need to be altered based on the intended use and the required material properties.
Population-based survival-cure analysis of ER-negative breast cancer.
Huang, Lan; Johnson, Karen A; Mariotto, Angela B; Dignam, James J; Feuer, Eric J
2010-08-01
This study investigated the trends over time in age and stage specific population-based survival of estrogen receptor negative (ER-) breast cancer patients by examining the fraction of cured patients and the median survival time for uncured patients. Cause-specific survival data from the Surveillance, Epidemiology, and End Results program for cases diagnosed during 1992-1998 were used in mixed survival cure models to evaluate the cure fraction and the extension in survival for uncured patients. Survival trends were compared with adjuvant chemotherapy data available from an overlapping patterns-of-care study. For stage II N+ disease, the largest increase in cure fraction was 44-60% (P = 0.0257) for women aged >or=70 in contrast to a 7-8% point increase for women aged <50 or 50-69 (P = 0.056 and 0.038, respectively). For women with stage III disease, the increases in the cure fraction were not statistically significant, although women aged 50-69 had a 10% point increase (P = 0.103). Increases in cure fraction correspond with increases in the use of adjuvant chemotherapy, particularly for the oldest age group. In this article, for the first time, we estimate the cure fraction for ER- patients. We notice that at age >o5r=70, the accelerated increase in cure fraction from 1992 to 1998 for women with stage II N+ compared with stage III suggests a selective benefit for chemotherapy in the lower stage group.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, S.; Chang, J.; Amin, S.
1981-01-01
Teste were conducted to determine the moisture retention for the 0.5 wt% borated concrete under three curing conditions. The three curing conditions are (1) curing at 100% relative humidity for a 28-day period at 21/degree/C, (2) curing at 100% relative humidity for a 7-day period, then at air-dry 50% relative humidity for the remaining 28-day curing period at 21/degree/C, and (3) curing at 100% relative humidity for a period of 7 days and then curing at air-dry 20% relative humidity for the remaining curing period at 21/degree/C. The concrete shielding curves are presented for several mositure contents. The results shouldmore » be helpful to assist the design of a cost effective concrete shield for fusion facilities.« less
Hazar, Fatma Yağmur; Kaban, Güzin; Kaya, Mükerrem
2017-11-01
Pastırma, a Turkish dry-cured meat product, was cured at two different temperatures (4 or 10 °C) with two different curing agents (150 mg/kg NaNO 2 or 300 mg/kg KNO 3 ). The aim of this research was to determine the effects of these factors on biogenic amine content and other qualitative properties (pH, a w , color, residual nitrite, TBARS, NPN-M, microbiological properties). Residual nitrite was below 10 mg/kg in all samples. Both the curing agent and temperature were found to have a very significant effect on the TBARS value, and the curing agent had a significant effect on the NPN-M content. Curing at 10 °C increased the L* value; the use of nitrate increased the a* value. The use of nitrite had a negative effect on the growth of lactic acid bacteria. Micrococcus/Staphylococcus showed good growth in the presence of nitrate. In all samples, Enterobacteriaceae counts were below detectable levels. Neither temperature nor curing agent had significant effects on the amounts of tryptamine, cadaverine, histamine, tyramine, or spermine. There were very significant effects of temperature on the amount of putrescine and of the curing agent on the amount of spermidine.
NASA Astrophysics Data System (ADS)
Ahmad, Z.; Ansell, M. P.; Smedley, D.
2006-09-01
Results of an experimental investigation into the thermal behavior and mechanical properties of a room-temperature-cured epoxy adhesive (diglycidyl ether of bisphenol A, DGEBA) cross-linked with polyetheramines and filled with different fillers, namely nanosilica, liquid rubber (CTBN), and clay, are reported. The nanosilica and liquid rubber increased the flexural strength and elastic modulus of the adhesive systems; the addition of clay particles raised the elastic modulus significantly, but embrittled the adhesive. Establishing a correct cure time is very important for bonded-in timber structures, as it will affect the bond strength. A study on the effect of cure time on the flexural strength was carried out, from which it follows that the adhesives should be cured for at least 20 days at room temperature. The damping characteristics and the glass-transition temperature of the adhesives were determined by using a dynamic mechanical thermal analysis. The results showed that the filled adhesives had a higher storage modulus, which was in agreement with the elastic moduli determined from static bending tests. The introduction of the fillers increased its glass-transition temperature considerably.
Assessing the irradiance delivered from light-curing units in private dental offices in Jordan.
Maghaireh, Ghada A; Alzraikat, Hanan; Taha, Nessrin A
2013-08-01
The authors conducted a study to examine the irradiance from light-curing units (LCUs) used in dental offices in Jordan. Two of the authors visited 295 private dental offices (15 percent) in Jordan and collected the following information about the LCUs: age, type (quartz-tungsten-halogen or light-emitting diode), date of last maintenance, type of maintenance, last date of use, number of times used during the day, availability of a radiometer, exposure time for each resin-based composite increment, size of light-curing tips and presence of resin-based composite on the tips. The authors used a radiometer to measure the irradiance from the LCUs. They used linear regression with stepwise correlation for the statistical analysis. The authors set the minimum acceptable irradiance at 300 milliwatts/square centimeter. The mean irradiance of the 295 LCUs examined was 361 mW/cm(2), and 136 LCUs (46.1 percent) delivered an irradiance of less than 300 mW/cm(2). The unit's age, type and presence of resin-based composite on the light-curing tips had a significant effect on the irradiance (P ≤ .001). Only 37 of the 141 quartz-tungsten-halogen units (26.2 percent) and 122 of the 154 light-emitting diode units (79.2 percent) delivered at least 300 mW/cm(2). Resin contamination on the light-curing tips had a significant effect on the irradiance delivered. The irradiance from the LCUs decreased with use. Practical Implications. The irradiance from many of the units in this study was less than 300 mW/cm(2), which may affect the quality of resin-based composite restorations. Dentists should monitor the performance of the LCUs in their offices weekly.
Öztürk, Elif; Bolay, Sükran; Hickel, Reinhard; Ilie, Nicoleta
2014-10-01
The aim of this study was to evaluate the micromechanical properties of different adhesive bonding agents when polymerized through ceramics. Sixty sound extracted human third molars were selected and the crowns were sectioned perpendicular to the long axis in order to obtain dentin slices to be bonded with one of the following adhesives: Syntac/Heliobond (Ivoclar-Vivadent) or Adper-Scotchbond-1XT (3M-ESPE). The adhesives were cured by using a LED-unit (Bluephase®, Ivoclar Vivadent) with three different curing times (10 s, 20 s and 30 s) under two ceramics (IPS-e.max-Press, Ivoclar-Vivadent; IPS-Empress®CAD, Ivoclar-Vivadent) of different thicknesses (0 mm, 0.75 mm, 2 mm). Thirty groups were included, each containing 60 measurements. Micromechanical properties (Hardness, HV; indentation modulus, E; and creep, Cr) of the adhesives were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). Data were statistically analyzed by using one-way ANOVA and Tukey's post-hoc test, as well as a multivariate analysis to test the influence of the study parameters (SPSS 18.0). Significant differences were observed between the micromechanical properties of the adhesives (p < 0.05). The ceramic type showed the highest effect on HV (Partial-eta squared (η(2)) = 0.109) of the tested adhesives, while E (η(2) = 0.275) and Cr (η(2) = 0.194) were stronger influenced by the adhesive type. Ceramic thickness showed no effect on the E and Cr of the adhesives. The adhesive bonding agents used in this study performed well by curing through different thicknesses of ceramics. The micromechanical properties of the adhesives were determined by the adhesive type and were less influenced by ceramic type and curing time.
Investigation into improved pavement curing materials and techniques : part 2 (phase III).
DOT National Transportation Integrated Search
2003-03-01
Appropriate curing is important for concrete to obtain the designed properties. This research was conducted to evaluate the curing : effects of different curing materials and methods on pavement properties. At present the sprayed curing compound is a...
Facile fabrication of superhydrophobic films with fractal structures using epoxy resin microspheres
NASA Astrophysics Data System (ADS)
Quan, Yun-Yun; Zhang, Li-Zhi
2014-02-01
A simple method has been developed to fabricate superhydrophobic surfaces with fractal structures with epoxy resin microspheres (ERMs). The ERMs is produced by phase separation in an epoxy-amine curing system with a silica sol (SS) dispersant. The transparent epoxy solution becomes cloudy and turns into epoxy suspension (ES) in this process. The fractal structure (two tier structure) generated by synthetic epoxy resin microspheres (ERMs) and deposited nanoincrutations on the surfaces of these ERMs, which have been observed by scanning electron microscope (SEM). The curing time of ES is an important condition to obtain films with good comprehensive performances. Superhydrophobic films can be prepared by adding extra SS into ES with a curing time longer than 5 h. The optimal curing time is 10 h to fabricate a film with good mechanical stability and high superhydrophobicity. In addition, a surface with anti-wetting property of impacting microdroplets can be fabricated by prolonging the curing time of ES to 24 h. The gradually decreased hydrophilic groups resulted from a longer curing time enable the surface to have smaller surface adhesions to water droplets, which is the main reason to keep its superhydrophobicity under impacting conditions. The coated surface is highly hydrophobic and the impacting water droplets are bounced off from the surface.
Ilie, Nicoleta
2017-05-01
The study aims to characterise the curing behaviour of a light-curing luting composite (Variolink® Aesthetic LC, Ivoclar Vivadent) polymerised at different exposure times (10 s, 20 s) through different ceramics (IPS Empress CAD and IPS e.max CAD, Ivoclar Vivadent) and ceramic thicknesses (no ceramic, 0.5, 1, 1.5 and 2 mm). Curing units' (Bluephase Style, Ivoclar Vivadent) variation in irradiance delivered up to 10-mm exposure distance as well as the incident and transmitted irradiance and radiant exposure up to 6-mm ceramic thickness were assessed on a laboratory-grade spectrometer. A total of 216 (18 groups, n = 12) thin and flat luting composite specimens of 500-μm thickness were prepared and stored after curing in a saturated vapour atmosphere for 24 h at 37 °C. Micro-mechanical properties (Vickers hardness, HV and indentation modulus, Y HU ) were determined by means of an automatic micro-hardness indenter. Within the study design, the radiant exposure received by the luting composite varied from 2.56 to 24.75 J/cm 2 , showing a high impact on the measured properties. Comparing the effect of the parameters exposure time, ceramic thickness and type, the highest influence on the micro-mechanical parameters was identified for exposure time, while this influence was stronger on HV (p < 0.001, η P 2 = 0.452) than on Y HU (p < 0.001, η P 2 = 0.178). The influence of ceramic type was significant but low (η P 2 = 0.161 on HV and 0.113 on Y HU ), while the influence of ceramic thickness was the lowest (η P 2 = 0.04 and 0.05, respectively). Slightly higher irradiance values were transmitted through Empress CAD up to a ceramic thickness of 3 mm (p < 0.001), while being comparable with e.max for thicker slices. Differences in translucency between ceramics were reflected in the micro-mechanical properties of the luting composite. The radiant exposure reaching the luting composite is determined by the incident irradiance, exposure time, ceramic type and ceramic thickness. At the analysed incident irradiance, exposure time was the most consistent parameter affecting the micro-mechanical properties of the luting composite, and this effect was strongly reflected in the more translucent ceramic Empress CAD. Within the curing conditions, an exposure time of 20 s is recommended.
NASA Astrophysics Data System (ADS)
Mu, Hai-Bin; Zhang, Man-Ling; Zhang, Xiao-Qiang; Zhang, Feng-Qiu; Kong, De-Jia; Tang, Li-Bin
1998-11-01
The patients who suffer from upper digestive tract tumor, such as cancer of esophagus, cancer of cardia, all have serious obstruction and fail to get nutrition and can not bear the strike of the radiotherapy and chemotherapy. In order to reduce the obstruction symptom and suffering of the patients and to prolong their life time, since 1989, our hospital used the laser to cure the upper digestive tract tumor 11 cases with serious obstruction and got remarkable curative effect.
NASA Astrophysics Data System (ADS)
Hastuty, I. P.; Roesyanto, R.; Napitupulu, S. M. A.
2018-02-01
Most areas in Indonesia consist of clay soils with high plasticity so that to meet technical requirements the soil needs improvement, which is known as soil stabilization.There are three ways of soil stabilization process, i.e. mechanical, physical and chemical. In this study, chemical stabilization was performed, that was by adding stabilizing agents to the soil. The stabilizing agent used was the ash of Mount Sinabung. Since 2010 until now, Sinabung Mountain is still experiencing eruption that produces a lot of volcanic ash and it inconveniences the environment. So, it is expected that this research will be able to optimize the utilization of Sinabung ash. The purpose of this study was to investigate the effect of the addition of Mount Sinabung ash to CBR (California Bearing Ratio) value, to determine the effect of the curing time of one day and fourteen days mixture on the CBR value, and to find the mixed content with effective curing time to produce the largest CBR value. Based on this study, the soil type CL (Clay - Low Plasticity) was obtained, based on the classification of USCS (Unified Soil Classification System) and categorized as A-6 (6) based on the classification of AASHTO (American Association of State Highway and Transportation officials) with the most effective mixed stabilizer material which was the variation of 10% Mount Sinabung ash with fourteen days of curing time. The CBR value resulted from the mixture of 10% Sinabung ash that was cured within fourteen days was 8.95%. By the increase of the content of the Sinabung ash, the CBR value always improved to the level of 10%, Sinabung ash then decreased and became constant at the mixture of higher volcanic ash mixture but remained above the CBR value of the original soil.
Materials Analysis and Modeling of Underfill Materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyatt, Nicholas B; Chambers, Robert S.
2015-08-01
The thermal-mechanical properties of three potential underfill candidate materials for PBGA applications are characterized and reported. Two of the materials are a formulations developed at Sandia for underfill applications while the third is a commercial product that utilizes a snap-cure chemistry to drastically reduce cure time. Viscoelastic models were calibrated and fit using the property data collected for one of the Sandia formulated materials. Along with the thermal-mechanical analyses performed, a series of simple bi-material strip tests were conducted to comparatively analyze the relative effects of cure and thermal shrinkage amongst the materials under consideration. Finally, current knowledge gaps asmore » well as questions arising from the present study are identified and a path forward presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Zemei; Department of Civil, Architectural and Environmental Engineering, Missouri University of Science and Technology, Rolla 65409, MO; Khayat, Kamal Henri, E-mail: khayatk@mst.edu
Bond properties between fibers and cementitious matrix have significant effect on the mechanical behavior of composite materials. In this study, the development of steel fiber-matrix interfacial bond properties in ultra-high strength concrete (UHSC) proportioned with nano-SiO{sub 2} varying between 0 and 2%, by mass of cementitious materials, was investigated. A statistical model relating either bond strength or pullout energy to curing time and nano-SiO{sub 2} content was proposed by using the response surface methodology. Mercury intrusion porosimetry (MIP) and backscatter scanning electron microscopy (BSEM) were used to characterize the microstructure of the matrix and the fiber-matrix interface, respectively. Micro-hardness aroundmore » the embedded fiber and hydration products of the matrix were evaluated as well. Test results indicated that the optimal nano-SiO{sub 2} dosage was 1% in terms of the bond properties and the microstructure. The proposed quadratic model efficiently predicted the bond strength and pullout energy with consideration of curing time and nano-SiO{sub 2} content. The improvement in bond properties associated with nano-silica was correlated with denser matrix and/or interface and stronger bond and greater strength of hydration products based on microstructural analysis.« less
Roy, Konda Karthik; Kumar, Kanumuru Pavan; John, Gijo; Sooraparaju, Sujatha Gopal; Nujella, Surya Kumari; Sowmya, Kyatham
2018-01-01
Aim: The aim of this study is to compare and to evaluate effect of curing light and curing modes on the nanohybrid composite resins with conventional Bis-GMA and novel tricyclodecane (TCD) monomers. Methodology: Two nanohybrid composites, IPS empress direct and charisma diamond were used in this study. Light-emitting diode (LED)-curing unit and quartz-tungsten-halogen (QTH)-curing unit which were operated into two different modes: continuous and soft start. Based on the composite resin, curing lights, and mode of curing used, the samples were divided into 8 groups. After polymerization, the samples were stored for 48 h in complete darkness at 37°C and 100% humidity. The Vickers hardness (VK) of the surface was determined with Vickers indenter by the application of 200 g for 15 s. Three VK readings were recorded for each sample surface both on top and bottom surfaces. For all the specimens, the three hardness values for each surface were averaged and reported as a single value. The mean VK and hardness ratio were calculated. The depth of cure was assessed based on the hardness ratio. Results: Comparison of mean hardness values and hardness ratios was done using ANOVA with post hoc Tukey's test. Conclusion: Both QTH- and LED-curing units had shown the adequate depth of cure. Soft-start-curing mode in both QTH- and LED-curing lights had effectively increased microhardness than the continuous mode of curing. TCD monomer had shown higher hardness values compared with conventional Bis-GMA-containing resin. PMID:29628651
de Oliveira, Dayane Carvalho Ramos Salles; Rocha, Mateus Garcia; Gatti, Alexandre; Correr, Americo Bortolazzo; Ferracane, Jack Liborio; Sinhoret, Mario Alexandre Coelho
2015-12-01
To evaluate the effect of photoinitiators and reducing agents on cure efficiency and color stability of resin-based composites using different LED wavelengths. Model resin-based composites were associated with diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO), phenylbis(2,4,6-trimethylbenzoyl) phosphine oxide (BAPO) or camphorquinone (CQ) associated with 2-(dimethylamino) ethyl methacrylate (DMAEMA), ethyl 4-(dimethyamino) benzoate (EDMAB) or 4-(N,N-dimethylamino) phenethyl alcohol (DMPOH). A narrow (Smartlite, Dentisply) and a broad spectrum (Bluephase G2, Ivoclar Vivadent) LEDs were used for photo-activation (20 J/cm(2)). Fourier transform infrared spectroscopy (FT-IR) was used to evaluate the cure efficiency for each composite, and CIELab parameters to evaluated color stability (ΔE00) after aging. The UV-vis absorption spectrophotometric analysis of each photoinitiator and reducing agent was determined. Data were analyzed using two-way ANOVA and Tukey's test for multiple comparisons (α=0.05). Higher cure efficiency was found for type-I photoinitiators photo-activated with a broad spectrum light, and for CQ-systems with a narrow band spectrum light, except when combined with an aliphatic amine (DMAEMA). Also, when combined with aromatic amines (EDMAB and DMPOH), similar cure efficiency with both wavelength LEDs was found. TPO had no cure efficiency when light-cured exclusively with a blue narrowband spectrum. CQ-systems presented higher color stability than type-I photoinitiators, especially when combined with DMPOH. After aging, CQ-based composites became more yellow and BAPO and TPO lighter and less yellow. However, CQ-systems presented higher color stability than type-I photoinitiators, as BAPO- and TPO-, despite their higher cure efficiency when photo-activated with corresponding wavelength range. Color matching is initially important, but color change over time will be one of the major reasons for replacing esthetic restorations; despite the less yellowing of these alternative photoinitiators, camphorquinone presented higher color stability. Copyright © 2015 Elsevier Ltd. All rights reserved.
The effect of curing conditions on the durability of high performance concrete
NASA Astrophysics Data System (ADS)
Bumanis, G.; Bajare, D.
2017-10-01
This study researches compressive strength and durability of the high strength self-compacting concrete (SCC) impacted at early stage by the curing conditions. The mixture compositions of metakaolin containing waste and cenospheres as partial cement replacement (15 wt%) were compared to reference SCC with 100% cement. The specimens prepared in advance were demoulded 24h after casting of the SCC and the specific curing conditions were applied for up to 28 days: standard water curing at 20°C (i); indoor curing at 20°C, RH 60% (ii) and low temperature air curing (2°C) at RH 60% (iii). Results indicate that at early stage (14 days) indoor curing conditions increase compressive strength of the SCC whilst no strength loss has been detected even at a low temperature curing. The further strength gain has been substantially reduced for samples cured indoor and at a low temperature with significant variation observed for long term compressive strength (180 days). The metakaolin containing waste has proved to be an effective partial cement replacement and it has improved strength gain even at a low temperature curing. Meanwhile cenospheres have reduced the SCC strength and with no positive effect on strength observed within the standard term. Freeze-thaw durability and resistance to the chloride penetration have been improved for the SCC cured at low temperature. The SCC with metakaolin containing waste has proved to be the most durable thus demonstrating importance of effective micro filler use.
NASA Astrophysics Data System (ADS)
Hudson, Tyler Blake
An in-process, in-situ cure monitoring technique utilizing a guided wave-based concept for carbon fiber reinforced polymer (CFRP) composites was investigated. Two automated cure monitoring systems using guided-wave ultrasonics were developed for characterizing the state of the cure. In the first system, surface mounted high-temperature piezoelectric transducer arrays were employed for actuation and sensing. The second system motivated by the success of the first system includes a single piezoelectric disc, bonded onto the surface of the composite for excitation; fiber Bragg gratings (FBGs) and/or phase-shifted fiber Bragg gratings (PSFBGs) were embedded in the composite for distributed cure sensing. Composite material properties (viscosity and degree of cure) evolved during cure of the panels fabricated from HexcelRTM IM7/8552 prepreg correlated well to the amplitude, time of arrival, and group velocity of the guided wave-based measurements during the cure cycle. In addition, key phase transitions (gelation and vitrification) were clearly identified from the experimental data during the same cure cycle. The material properties and phase transitions were validated using cure process modeling software (e.g., RAVENRTM). The high-temperature piezoelectric transducer array system demonstrated the feasibility of a guided wave-based, in-process, cure monitoring and provided the framework for defect detection during cure. Ultimately, this system could provide a traceable data stream for non-compliance investigations during serial production and perform closed-loop process control to maximize composite panel quality and consistency. In addition, this system could be deployed as a "smart" caul/tool plate to existing production lines without changing the design of the aircraft/structure. With the second system, strain in low frequency (quasi-static) and the guided wavebased signals in several hundred kilohertz range were measured almost simultaneously using the same FBG or PS-FBG throughout the cure cycle. Also, the residual strain can be readily determined at the end of the cure. This system demonstrated a real-time, in-situ, cure monitoring system using embedded multiplexed FBG/PS-FBG sensors to record both guided wave-based signals and strain. The distinct advantages of a fiber optic-based system include multiplexing, small size, embedding, utilization in harsh environments, electrically passive operation, and electromagnetic interference (EMI) immunity. The embedded multiplexed FBG/PS-FBG fiber optic sensor can monitor the entire life-cycle of the composite structure from curing, post-cure/assembly, and in-service for creating "smart structures".
Application of a Non-Mixture Cure Rate Model for Analyzing Survival of Patients with Breast Cancer.
Baghestani, Ahmad Reza; Moghaddam, Sahar Saeedi; Majd, Hamid Alavi; Akbari, Mohammad Esmaeil; Nafissi, Nahid; Gohari, Kimiya
2015-01-01
As a result of significant progress made in treatment of many types of cancers during the last few decades, there have been an increased number of patients who do not experience mortality. We refer to these observations as cure or immune and models for survival data which include cure fraction are known as cure rate models or long-term survival models. In this study we used the data collected from 438 female patients with breast cancer registered in the Cancer Research Center in Shahid Beheshti University of Medical Sciences, Tehran, Iran. The patients had been diagnosed from 1992 to 2012 and were followed up until October 2014. We had to exclude some because of incomplete information. Phone calls were made to confirm whether the patients were still alive or not. Deaths due to breast cancer were regarded as failure. To identify clinical, pathological, and biological characteristics of patients that might have had an effect on survival of the patients we used a non-mixture cure rate model; in addition, a Weibull distribution was proposed for the survival time. Analyses were performed using STATA version 14. The significance level was set at P ≤ 0.05. A total of 75 patients (17.1%) died due to breast cancer during the study, up to the last follow-up. Numbers of metastatic lymph nodes and histologic grade were significant factors. The cure fraction was estimated to be 58%. When a cure fraction is not available, the analysis will be changed to standard approaches of survival analysis; however when the data indicate that the cure fraction is available, we suggest analysis of survival data via cure models.
Dual and self-curing potential of self-adhesive resin cements as thin films.
Moraes, R R; Boscato, N; Jardim, P S; Schneider, L F J
2011-01-01
In this study, the dual- and self-curing potential of self-adhesive resin cements (SARCs) as thin, clinically-relevant cement films was investigated. The SARCs tested were: BisCem (BSC; Bisco), Maxcem Elite (MXE; Kerr), RelyX Unicem clicker (UNI; 3M ESPE), seT capsule (SET; SDI), and SmartCem 2 (SC2; Dentsply Caulk). The conventional cement RelyX ARC (3M ESPE) was tested as a reference. The degree of conversion (DC) as a function of time was evaluated by real-time Fourier transform infrared spectroscopy with an attenuated total reflectance (ATR) device. The cements were either photoactivated for 40 seconds (dual-cure mode) or not photoactivated (self-cure mode). The cement film thickness was 50 ± 10 μm. The DC (%) was evaluated 1, 5, 10, 15, 20, 25, and 30 minutes after placing the cement on the ATR cell. Data for DC as a function of time were analyzed by two-way repeated measures analysis of variance (ANOVA). DC values at 30 minutes for the self- and dual-cure modes were submitted to one-way ANOVA. Post hoc comparisons were performed using the Student-Newman-Keuls test (p<0.05). The rate and the extent of conversion were lower for the SARCs compared with the conventional cement. Means ± standard deviations (SD) for the dual-cure mode at 30 minutes were: 75 ± 5 (ARC)a, 73 ± 8 (SET)a, 61 ± 4 (MXE)b, 51 ± 9 (BSC)c, 51 ± 4 (UNI)c, and 48 ± 3 (SC2)c, while in the self-cure mode means and SD were 62 ± 6 (ARC)a, 54 ± 3 (MXE)b, 40 ± 6 (SC2)c, 35 ± 2 (UNI)c, 35 ± 3 (SET)c, and 11 ± 3 (BSC)d. The DC for the dual-cure mode was generally higher than the self-cure, irrespective of the time. Discrepancies in DC between the dual- and self-cure modes from 11% to 79% were observed. In conclusion, SARCs may present slower rate of polymerization and lower final DC than conventional resin cements, in either the dual- or self-cure mode.
Accounting for Cured Patients in Cost-Effectiveness Analysis.
Othus, Megan; Bansal, Aasthaa; Koepl, Lisel; Wagner, Samuel; Ramsey, Scott
2017-04-01
Economic evaluations often measure an intervention effect with mean overall survival (OS). Emerging types of cancer treatments offer the possibility of being "cured" in that patients can become long-term survivors whose risk of death is the same as that of a disease-free person. Describing cured and noncured patients with one shared mean value may provide a biased assessment of a therapy with a cured proportion. The purpose of this article is to explain how to incorporate the heterogeneity from cured patients into health economic evaluation. We analyzed clinical trial data from patients with advanced melanoma treated with ipilimumab (Ipi; n = 137) versus glycoprotein 100 (gp100; n = 136) with statistical methodology for mixture cure models. Both cured and noncured patients were subject to background mortality not related to cancer. When ignoring cured proportions, we found that patients treated with Ipi had an estimated mean OS that was 8 months longer than that of patients treated with gp100. Cure model analysis showed that the cured proportion drove this difference, with 21% cured on Ipi versus 6% cured on gp100. The mean OS among the noncured cohort patients was 10 and 9 months with Ipi and gp100, respectively. The mean OS among cured patients was 26 years on both arms. When ignoring cured proportions, we found that the incremental cost-effectiveness ratio (ICER) when comparing Ipi with gp100 was $324,000/quality-adjusted life-year (QALY) (95% confidence interval $254,000-$600,000). With a mixture cure model, the ICER when comparing Ipi with gp100 was $113,000/QALY (95% confidence interval $101,000-$154,000). This analysis supports using cure modeling in health economic evaluation in advanced melanoma. When a proportion of patients may be long-term survivors, using cure models may reduce bias in OS estimates and provide more accurate estimates of health economic measures, including QALYs and ICERs. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Hedges, L. M. (Editor)
1973-01-01
Detailed data are presented on phenolic-glass and phenolic-asbestos compounds which compare the effect of compression molding without degas to the effects of four variations of compression molding. These variations were designed to improve elimination of entrapped volatiles and the volatile products of the condensate reaction associated with the cure of phenolic resins. The utilization of conventional methods of degas plus degas by vacuum and directional heat flow methods are involved. Detailed data are also presented on these same compounds, comparing the effect of changes in post-bake time, and post-bake temperature for the five molding techniques.
Singh, Sunint; Palaskar, Jayant N.; Mittal, Sanjeev
2013-01-01
Background: Conventional heat cure poly methyl methacrylate (PMMA) is the most commonly used denture base resin despite having some short comings. Lengthy polymerization time being one of them and in order to overcome this fact microwave curing method was recommended. Unavailability of specially designed microwavable acrylic resin made it unpopular. Therefore, in this study, conventional heat cure PMMA was polymerized by microwave energy. Aim and Objectives: This study was designed to evaluate the surface porosities in PMMA cured by conventional water bath and microwave energy and compare it with microwavable acrylic resin cured by microwave energy. Materials and Methods: Wax samples were obtained by pouring molten wax into a metal mold of 25 mm × 12 mm × 3 mm dimensions. These samples were divided into three groups namely C, CM, and M. Group C denotes conventional heat cure PMMA cured by water bath method, CM denotes conventional heat cure PMMA cured by microwave energy, M denotes specially designed microwavable acrylic denture base resin cured by microwave energy. After polymerization, each sample was scanned in three pre-marked areas for surface porosities using the optical microscope. As per the literature available, this instrument is being used for the first time to measure the porosity in acrylic resin. It is a reliable method of measuring area of surface pores. Portion of the sample being scanned is displayed on the computer and with the help of software area of each pore was measured and data were analyzed. Results: Conventional heat cure PMMA samples cured by microwave energy showed maximum porosities than the samples cured by conventional water bath method and microwavable acrylic resin cured by microwave energy. Higher percentage of porosities was statistically significant, but well within the range to be clinically acceptable. Conclusion: Within the limitations of this in-vitro study, conventional heat cure PMMA can be cured by microwave energy without compromising on its property such as surface porosity. PMID:24015000
Kang, Da-Cheng; Gao, Xue-Qin; Ge, Qing-Feng; Zhou, Guang-Hong; Zhang, Wan-Gang
2017-09-01
The objective of this study was to explore the mechanisms of power ultrasound (PUS, 150 and 300W) and treatment time (30 and 120min) on the water-holding capacity (WHC) and tenderness of beef during curing. Beef muscle at 48h post mortem was subjected to PUS treatment at a frequency of 20kHz. Analysis of compression loss and shear force showed that PUS-assisted curing significantly increased the WHC and the tenderness of beef compared to static brining (p<0.05). According to the analysis of LF-NMR, PUS treatment could increase the P 21 values which indicated an improvement in water-binding ability of beef muscle. SDS-PAGE and LC-ESI-MS/MS analysis suggested that PUS induced moderate oxidation of myosin causing polymerization, which may contribute to increased water retention. On the other hand, an increased tenderness of beef is suggested by the increased MFI values and proteolysis of desmin and troponin-T. Transmission electron microscopy (TEM) further supported the effects of PUS on WHC and tenderness changes due to the swelling and disruption of myofibrils. Thus, these results provide knowledge about the mechanism for improving WHC and tenderness of beef by PUS curing, which could be employed as an emerging technology for various meat curing processes. Copyright © 2017 Elsevier B.V. All rights reserved.
Chemorheology of in-mold coating for compression molded SMC applications
NASA Astrophysics Data System (ADS)
Ko, Seunghyun; Straus, Elliott J.; Castro, Jose M.
2015-05-01
In-mold coating (IMC) is applied to compression molded sheet molding compound (SMC) exterior automotive or truck body panels as an environmentally friendly alternative to make the surface conductive for subsequent electrostatic painting operations. The coating is a thermosetting liquid that when injected onto the surface of the part cures and bonds to provide a smooth conductive surface. In order to optimize the IMC process, it is essential to predict the time available for flow, that is the time before the thermosetting reaction starts (inhibition time) as well as the time when the coating has enough structural integrity so that the mold can be opened without damaging the part surface (cure time). To predict both the inhibition time and the cure time, it is critical to study the chemorheology of IMC. In this paper, we study the chemorheology for a typical commercial IMC system, and show its relevance to both the flow and cure time for the IMC stage during SMC compression molding.
Curing of Thick Thermoset Composite Laminates: Multiphysics Modeling and Experiments
NASA Astrophysics Data System (ADS)
Anandan, S.; Dhaliwal, G. S.; Huo, Z.; Chandrashekhara, K.; Apetre, N.; Iyyer, N.
2017-11-01
Fiber reinforced polymer composites are used in high-performance aerospace applications as they are resistant to fatigue, corrosion free and possess high specific strength. The mechanical properties of these composite components depend on the degree of cure and residual stresses developed during the curing process. While these parameters are difficult to determine experimentally in large and complex parts, they can be simulated using numerical models in a cost-effective manner. These simulations can be used to develop cure cycles and change processing parameters to obtain high-quality parts. In the current work, a numerical model was built in Comsol MultiPhysics to simulate the cure behavior of a carbon/epoxy prepreg system (IM7/Cycom 5320-1). A thermal spike was observed in thick laminates when the recommended cure cycle was used. The cure cycle was modified to reduce the thermal spike and maintain the degree of cure at the laminate center. A parametric study was performed to evaluate the effect of air flow in the oven, post cure cycles and cure temperatures on the thermal spike and the resultant degree of cure in the laminate.
Liquid crystal materials and tunable devices for optical communications
NASA Astrophysics Data System (ADS)
Du, Fang
In this dissertation, liquid crystal materials and devices are investigated in meeting the challenges for photonics and communications applications. The first part deals with polymer-stabilized liquid crystal (PSLC) materials and devices. Three polymer-stabilized liquid crystal systems are developed for optical communications. The second part reports the experimental investigation of a novel liquid-crystal-infiltrated photonic crystal fiber (PCF) and explores its applications in fiber-optic communications. The curing temperature is found to have significant effects on the PSLC performance. The electro-optic properties of nematic polymer network liquid crystal (PNLC) at different curing temperatures are investigated experimentally. At high curing temperature, a high contrast, low drive voltage, and small hysteresis PNLC is obtained as a result of the formed large LC microdomains. With the help of curing temperature effect, it is able to develop PNLC based optical devices with highly desirable performances for optical communications. Such high performance is generally considered difficult to realize for a PNLC. In fact, the poor performance of PNLC, especially at long wavelengths, has hindered it from practical applications for optical communications for a long time. Therefore, the optimal curing temperature effect discovered in this thesis would enable PSLCs for practical industrial applications. Further more, high birefringence LCs play an important role for near infrared photonic devices. The isothiocyanato tolane liquid crystals exhibit a high birefringence and low viscosity. The high birefringence LC dramatically improves the PSLC contrast ratio while keeping a low drive voltage and fast response time. A free-space optical device by PNLC is experimentally demonstrated and its properties characterized. Most LC devices are polarization sensitive. To overcome this drawback, we have investigated the polymer-stabilized cholesteric LC (PSCLC). Combining the curing temperature effect and high birefringence LC, a polarization independent fiber-optical device is realized with over 30 dB attenuation, ˜12 V rms drive voltage and 11/28 milliseconds (rise/decay) response times. A polymer-stabilized twisted nematic LC (PS TNLC) is also proposed as a variable optical attenuator for optical communications. By using the polarization control system, the device is polarization independent. The polymer network in a PS TNLC not only results in a fast response time (0.9/9 milliseconds for rise/decay respectively), but also removes the backflow effect of TNLC which occurs in the high voltage regime. Another major achievement in this thesis is the first demonstration of an electrically tunable LC-infiltrated photonic crystal fiber (PCF). Two different LC PCF configurations are studied. For the first time, electrically tunable LC PCFs are demonstrated experimentally. The guiding mechanism and polarization properties are studied. Preliminary experimental results are also given for the thermo-optical properties of a LC filled air-core PCF. In conclusion, this dissertation has solved important issues related to PSLC and enables its applications as VOAs and light shutters in optical communications. Through experimental investigations of the LC filled PCFs, a new possibility of developing tunable micro-sized fiber devices is opened for optical communications as well.
Sampaio, Paula Costa Pinheiro; Kruly, Paula de Castro; Ribeiro, Clara Cabral; Hilgert, Leandro Augusto; Pereira, Patrícia Nóbrega Rodrigues; Scaffa, Polliana Mendes Candia; Di Hipólito, Vinicius; D'Alpino, Paulo Henrique Perlatti; Garcia, Fernanda Cristina Pimentel
2017-11-01
The purpose of this in vitro study was to evaluate the bonding ability and monomer conversion of a universal adhesive system applied to dentin as functions of different curing times and storage. The results were compared among a variety of commercial adhesives. Flat superficial dentin surfaces were exposed on human molars and assigned into one of the following adhesives (n = 15): total-etch Adper Single Bond 2 (SB) and Optibond Solo Plus (OS), self-etch Optibond All in One (OA) and Clearfil SE Bond (CSE), and Scotchbond Universal Adhesive in self-etch mode (SU). The adhesives were applied following the manufacturers' instructions and cured for 10, 20, or 40s. Specimens were processed for the microtensile bond strength (µTBS) test in accordance with the non-trimming technique and tested after 24h and 2 years. The fractured specimens were classified under scanning electron microscopy (SEM). Infrared (IR) spectra were obtained and monomer conversion (%) was calculated by comparing the aliphatic-to-aromatic IR absorption peak ratio before and after polymerization (n=5). Data were analyzed by 2-way ANOVA/Tukey's tests (α = 0.05). At 24-h evaluation, OA and CSE presented similar bond strength means irrespective of the curing time, whereas SB and SU exhibited significantly higher means when cured for 40s as did OS when cured for 20 or 40s (p < 0.05). At 2-year evaluation, only OA exhibited significantly higher bond strength when cured for 20 and 40s (p < 0.05). When the evaluation times were compared, OA also exhibited the same bonding ability when cured for longer periods of time (20 and 40s). All of the adhesives tested exhibited significantly lower monomer conversion when photoactivated according to the manufacturers' instructions (10s). Higher monomer conversions obtained with longer light exposure allow only higher immediate bond strength for most of the adhesives tested. After 2-year storage, only the self-etching adhesive Optibond All-In-One exhibited the same bonding ability when cured for longer periods of time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tiwari, Anil; Shyagali, Tarulatha; Kohli, Sarvraj; Joshi, Rishi; Gupta, Abhishek; Tiwari, Rana
2016-01-01
Aim: The aim of this in vitro study was to evaluate the influence of the Dental chair light on the bond strength of light cured composite resin. Materials and Methods: Sixty therapeutically extracted human premolar teeth were randomly allocated to two groups of 30 specimens each. In both groups light cured composite resin (Transbond XT) and MBT premolar metal brackets (3M Unitek) was used to bond brackets. In group I and II light curing was done using Light-emitting diode light curing units without and with the dental chair light respectively. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength and Adhesive Remnant Index (ARI) scores. Data was subjected to Mann Whitney U statistical test. Results: Results indicated that there was significantly higher shear bond strength (7.71 ± 1.90) for the Group II (composite cured with LED and dental chair light) compared with Group I (composite cured with LED LCU only) (5.74 ± 1.13).the obtained difference was statistically significant. There was no statistical significant difference between ARI scores in between the groups. Conclusions: light cure bonding with dental chair light switched on will produce greater bond strength than the conventional bonding. However, the ARI score were similar to both the groups. It is advised that the inexperienced orthodontist should always switch off the dental chair light while bonding for enough working time during the bracket placement. PMID:28077886
Reyes, J; Chaffer, M; Sanchez, J; Torres, G; Macias, D; Jaramillo, M; Duque, P C; Ceballos, A; Keefe, G P
2015-08-01
A randomized controlled trial was performed in 17 Colombian dairy herds to determine the cure risk among cows subclinically infected with Streptococcus agalactiae exposed to 2 antibiotic therapies. Composite milk samples were collected before milking at the onset of the trial (pretreatment) and 2 subsequent times over a period of approximately 63 d. The intramammary application (IMM) of ampicillin-cloxacillin was compared with the intramuscular application (IM) of penethamate hydriodide, and cure risks after an initial and retreatment application were assessed. Cure risk after the initial treatment was higher (82.4%) for the IMM treatment than for IM therapy (65.8%). However, no difference was observed in the cure risk of refractory cases after retreatment (IMM=52.6% vs. IM=51.2%). The cumulative cure risk (both initial and retreatment) was 90.4 and 82.9% for the IMM and IM products, respectively. A 2-level random effects logistic model that controlled for pretreatment cow-level somatic cell count, indicated that IM treatment (odds ratio=0.37) had a lower cure risk than IMM and a tendency for a lower cure risk with increasing baseline somatic cell count. Our findings suggest that both products and administration routes can reduce the prevalence of S. agalactiae in affected herds, but the IMM product had a better efficacy in curing the infection. In addition to the treatment protocol, the cow somatic cell count should be considered when making management decisions for cows infected with S. agalactiae. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Watanabe, H; Kazama, Re; Asai, T; Kanaya, F; Ishizaki, H; Fukushima, M; Okiji, T
2015-01-01
This study aimed to evaluate the ability of high-intensity light-emitting diode (LED) and other curing units to cure dual-cured resin cement through ceramic material. A halogen curing unit (Jetlite 3000, Morita), a second-generation LED curing unit (Demi, Kerr), and two high-intensity LED curing units (PenCure 2000, Morita; Valo, Ultradent) were tested. Feldspathic ceramic plates (VITABLOCS Mark II, A3; Vita Zahnfabrik) with thicknesses of 1.0, 2.0, and 3.0 mm were prepared. Dual-cured resin cement samples (Clearfil Esthetic Cement, Kuraray Noritake Dental) were irradiated directly or through one of the ceramic plates for different periods (5, 10, 15, or 20 seconds for the high-intensity LED units and 20, 40, 60, or 80 seconds for the others). The Knoop hardness test was used to determine the level of photopolymerization that had been induced in the resin cement. Data were analyzed by one-way analysis of variance and Dunnett's post-hoc test to identify test-control (maximum irradiation without a ceramic plate) differences for each curing unit (p<0.05). For all curing units, the curing conditions had a statistically significant effect on the Knoop hardness numbers (KHNs) of the irradiated cement samples (p<0.001). In general, the KHN decreased with increasing plate thickness and increased as the irradiation period was extended. Jetlite 3000 achieved control-level KHN values only when the plate thickness was 1.0 mm. At a plate thickness ≥2.0 mm, the LED units (except for PenCure 2000 at 3.0 mm) were able to achieve control-level KHN values when the irradiation time was extended. At a plate thickness of 3.0 mm, irradiation for 20 seconds with the Valo or for 80 seconds with the Demi were the only methods that produced KHN values equivalent to those produced by direct irradiation. Regardless of the type of curing unit used, indirect irradiation of dual-cured resin cement through a ceramic plate resulted in decreased KHN values compared with direct irradiation. When the irradiation period was extended, only the LED units were able to achieve similar KHN values to those observed under direct irradiation in the presence of plates ≥2.0-mm thick. High-intensity LED units require a shorter irradiation period than halogen and second-generation LED curing units to obtain KHN values similar to those observed during direct irradiation.
Collective antibiotic treatment of trachoma
Reinhards, J.; Weber, A.; Maxwell-Lyons, F.
1959-01-01
By the early 1950's, it was clear from numerous independent reports that certain of the broad-spectrum antibiotics were effective against the agent of trachoma. It seemed, however, that treatment had to be continued over long periods to effect a cure of the average case. With the assistance of WHO, comparative trials on a scale hitherto unprecedented in the disease—involving more than 9000 schoolchildren with active trachoma—have been conducted in Morocco since 1953 in order to assess the value of local treatment of trachoma with chlortetracycline and to develop simple and economic methods of treatment, for which there was a pressing need. Local application of 1% chlortetracycline ointment two or three times daily for 60 days gave almost 80% cures under reasonably favourable conditions and nearly 100% cures after re-treatment of cases not cured by the first course. Equally good results followed intermittent short-term treatment over longer periods. Relapse and reinfection rates were low. Collective mass treatment with antibiotics is clearly a valuable method of trachoma control. The use of intermittent treatment allows for a great economy both in antibiotics and in staff and other campaign expenses and makes possible the wide expansion of mass treatment programmes. PMID:14437176
NASA Astrophysics Data System (ADS)
Krishnan, Thulasirajan; Purushothaman, Revathi
2017-07-01
There are several parameters that influence the properties of geopolymer concrete, which contains recycled concrete aggregate as the coarse aggregate. In the present study, the vital parameters affecting the compressive strength of geopolymer concrete containing recycled concrete aggregate are analyzedby varying four parameters with two levels using full factorial design in statistical software Minitab® 17. The objective of the present work is to gain an idea on the optimization, main parameter effects, their interactions and the predicted response of the model generated using factorial design. The parameters such as molarity of sodium hydroxide (8M and 12M), curing time (6hrs and 24 hrs), curing temperature (60°C and 90°C) and percentage of recycled concrete aggregate (0% and 100%) are considered. The results show that the curing time, molarity of sodium hydroxide and curing temperature were the orderly significant parameters and the percentage of Recycled concrete aggregate (RCA) was statistically insignificant in the production of geopolymer concrete. Thus, it may be noticeable that the RCA content had negligible effect on the compressive strength of geopolymer concrete. The expected responses from the generated model showed a satisfactory and rational agreement to the experimental data with the R2 value of 97.70%. Thus, geopolymer concrete comprising recycled concrete aggregate can solve the major social and environmental concerns such as the depletion of the naturally available aggregate sources and disposal of construction and demolition waste into the landfill.
Effects of Meat-curing Salts and Temperature on Production of Staphylococcal Enterotoxin B1
McLean, Ruth A.; Lilly, Helen D.; Alford, John A.
1968-01-01
We investigated the effect of time, temperature, and the presence of sodium chloride, nitrates, and nitrites in the medium on the growth and production of enterotoxin B by Staphylococcus aureus. Assays by the double gel-diffusion method showed that maximal enterotoxin B production occurs at the beginning of the stationary phase of growth. Lowering the temperature of incubation decreased the amount of toxin produced without affecting the total amount of growth. Increases in concentration of curing salts reduced toxin production more rapidly than cell growth. The relationship of these observations to food-poisoning outbreaks is briefly discussed. PMID:4967190
Assessment and prediction of drying shrinkage cracking in bonded mortar overlays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beushausen, Hans, E-mail: hans.beushausen@uct.ac.za; Chilwesa, Masuzyo
2013-11-15
Restrained drying shrinkage cracking was investigated on composite beams consisting of substrate concrete and bonded mortar overlays, and compared to the performance of the same mortars when subjected to the ring test. Stress development and cracking in the composite specimens were analytically modeled and predicted based on the measurement of relevant time-dependent material properties such as drying shrinkage, elastic modulus, tensile relaxation and tensile strength. Overlay cracking in the composite beams could be very well predicted with the analytical model. The ring test provided a useful qualitative comparison of the cracking performance of the mortars. The duration of curing wasmore » found to only have a minor influence on crack development. This was ascribed to the fact that prolonged curing has a beneficial effect on tensile strength at the onset of stress development, but is in the same time not beneficial to the values of tensile relaxation and elastic modulus. -- Highlights: •Parameter study on material characteristics influencing overlay cracking. •Analytical model gives good quantitative indication of overlay cracking. •Ring test presents good qualitative indication of overlay cracking. •Curing duration has little effect on overlay cracking.« less
NASA Technical Reports Server (NTRS)
Loos, Alfred C.; Weideman, Mark H.; Long, Edward R., Jr.; Kranbuehl, David E.; Kinsley, Philip J.; Hart, Sean M.
1991-01-01
A model was developed which can be used to simulate infiltration and cure of textile composites by resin transfer molding. Fabric preforms were resin infiltrated and cured using model generated optimized one-step infiltration/cure protocols. Frequency dependent electromagnetic sensing (FDEMS) was used to monitor in situ resin infiltration and cure during processing. FDEMS measurements of infiltration time, resin viscosity, and resin degree of cure agreed well with values predicted by the simulation model. Textile composites fabricated using a one-step infiltration/cure procedure were uniformly resin impregnated and void free. Fiber volume fraction measurements by the resin digestion method compared well with values predicted using the model.
Jafari-Koshki, Tohid; Mansourian, Marjan; Mokarian, Fariborz
2014-01-01
Breast cancer is a fatal disease and the most frequently diagnosed cancer in women with an increasing pattern worldwide. The burden is mostly attributed to metastatic cancers that occur in one-third of patients and the treatments are palliative. It is of great interest to determine factors affecting time from cancer diagnosis to secondary metastasis. Cure rate models assume a Poisson distribution for the number of unobservable metastatic-component cells that are completely deleted from the non-metastasis patient body but some may remain and result in metastasis. Time to metastasis is defined as a function of the number of these cells and the time for each cell to develop a detectable sign of metastasis. Covariates are introduced to the model via the rate of metastatic-component cells. We used non-mixture cure rate models with Weibull and log-logistic distributions in a Bayesian setting to assess the relationship between metastasis free survival and covariates. The median of metastasis free survival was 76.9 months. Various models showed that from covariates in the study, lymph node involvement ratio and being progesterone receptor positive were significant, with an adverse and a beneficial effect on metastasis free survival, respectively. The estimated fraction of patients cured from metastasis was almost 48%. The Weibull model had a slightly better performance than log-logistic. Cure rate models are popular in survival studies and outperform other models under certain conditions. We explored the prognostic factors of metastatic breast cancer from a different viewpoint. In this study, metastasis sites were analyzed all together. Conducting similar studies in a larger sample of cancer patients as well as evaluating the prognostic value of covariates in metastasis to each site separately are recommended.
Serati, Maurizio; Sorice, Paola; Bogani, Giorgio; Braga, Andrea; Cantaluppi, Simona; Uccella, Stefano; Caccia, Giorgio; Salvatore, Stefano; Ghezzi, Fabio
2017-01-01
To assess long-term subjective, objective, and urodynamic outcomes of retropubic mid-urethral slings at 13-year follow-up. This was a prospective observational study. Consecutive women with proven urodynamic stress incontinence were treated with standard retropubic tension free vaginal tape (TVT). Patients with mixed incontinence and/or anatomic evidence of pelvic organ prolapse were excluded. All the included patients underwent preoperative clinical and urodynamic evaluations. During follow-up examinations, women were assessed for subjective satisfaction and objective cure rates. The Cox model was used in order to investigate factors predicting the risk of recurrent stress urinary incontinence (SUI), over the study period. Overall, 55 patients were suitable for the analysis. At 13-year follow-up, 47 out of 55 (85.5%) patients declared themselves cured (p-for-trend 0.02) and 48 out of 58 (87.2%) were at least improved (p-for-trend 0.07). No significant deterioration of objective cure rates was observed over time (P = 0.29). At the time of the last evaluation, 50 out of 55 (90.9%) women were objectively cured; urodynamic evaluation confirmed this finding in 49 (89.1%) patients. Considering factors predictive of SUI recurrence, we observed that, via multivariate analysis, obesity (HR 7.2; P = 0.01) and maximum detrusor pressure during the voiding phase ≤29 cmH 2 O (HR 8.0; P = 0.01) were the only independent predictors of recurrent SUI. Our data confirmed that TVT is a highly effective and safe procedure also at 13-year follow-up. Interestingly, we observed a significant decrease of subjective satisfaction over time. Neurourol. Urodynam. 36:192-197, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Sindelar, J J; Cordray, J C; Sebranek, J G; Love, J A; Ahn, D U
2007-08-01
Vegetable juice powder (VJP) and a starter culture containing Staphylococcus carnosus have been identified as necessary ingredients for the manufacture of uncured, no-nitrate/nitrite-added meat products with quality and sensory attributes similar to traditional cured products. The objectives of this study were to determine the effects of varying concentrations of VJP and incubation time (MIN-HOLD) on quality characteristics, including lipid oxidation, color, and cured meat pigment concentrations, of ham over a 90-d storage period, compare residual nitrate and nitrite content, and determine if differences exist in sensory properties of finished products. Four ham treatments (TRT) (TRT 1: 0.20% VJP, 0 MIN-HOLD; TRT 2: 0.20% VJP, 120 MIN-HOLD; TRT 3: 0.35% VJP, 0 MIN-HOLD; TRT 4: 0.35% VJP, 120 MIN-HOLD) and a sodium nitrite-added control (C) were used for this study. No differences (P > 0.05) were observed between TRTs and C for CIE L*, a*, b*, and cured color measured by reflectance ratio. Lipid oxidation (TBARS) for combined TRTs and C revealed little change over time while the C had less (P < 0.05) lipid oxidation than TRTs 2 and 4 for combined days. No differences (P > 0.05) were reported for cured pigment concentration between TRTs and C. Trained sensory panel intensity ratings for ham and vegetable aroma, and flavor, color, and firmness showed that a high concentration (0.35%) of VJP resulted in the highest scores for undesirable vegetable aroma and flavor. Treatment combinations with a low concentration (0.20%) of VJP were comparable to the C for all sensory attributes.
Szlavecz, Akos; Chiew, Yeong Shiong; Redmond, Daniel; Beatson, Alex; Glassenbury, Daniel; Corbett, Simon; Major, Vincent; Pretty, Christopher; Shaw, Geoffrey M; Benyo, Balazs; Desaive, Thomas; Chase, J Geoffrey
2014-09-30
Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. Using CURE Soft, patient's respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient's respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes.
Fast Curing of Composite Wood Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dr. Arthur J. Ragauskas
2006-04-26
The overall objective of this program is to develop low temperature curing technologies for UF and PF resins. This will be accomplished by: • Identifying the rate limiting UF and PF curing reactions for current market resins; • Developing new catalysts to accelerate curing reactions at reduced press temperatures and times. In summary, these new curing technologies will improve the strength properties of the composite wood products and minimize the detrimental effects of wood extractives on the final product while significantly reducing energy costs for wood composites. This study is related to the accelerated curing of resins for wood compositesmore » such as medium density fiberboard (MDF), particle board (PB) and oriented strandboard (OSB). The latter is frequently manufactured with a phenol-formaldehyde resin whereas ureaformaldehyde (UF) resins are usually used in for the former two grades of composite wood products. One of the reasons that hinder wider use of these resins in the manufacturing of wood composites is the slow curing speed as well as inferior bondability of UF resin. The fast curing of UP and PF resins has been identified as an attractive process development that would allow wood to be bonded at higher moisture contents and at lower press temperatures that currently employed. Several differing additives have been developed to enhance cure rates of PF resins including the use of organic esters, lactones and organic carbonates. A model compound study by Conner, Lorenz and Hirth (2002) employed 2- and 4-hydroxymethylphenol with organic esters to examine the chemical basis for the reported enhanced reactivity. Their studies suggested that the enhance curing in the presence of esters could be due to enhanced quinone methide formation or enhanced intermolecular SN2 reactions. In either case the esters do not function as true catalysts as they are consumed in the reaction and were not found to be incorporated in the polymerized resin product. An alternative approach to accelerated PF curing can be accomplished with the addition amines or amides. The later functionality undergoes base catalyzed hydrolysis yielding the corresponding carboxyl ate and free amine which rapidly reacts with the phenolic methylol groups facilitating polymerization and curing of the PF resin (Pizzi, 1997).« less
Ogunyinka, A; Palin, W M; Shortall, A C; Marquis, P M
2007-07-01
The effect of photoinitiator and co-initiator chemistry on the setting reaction and degree of conversion of dental resin-based composites (RBCs) has rarely been determined explicitly. This work examines the effect of type and concentration of photoinitiator and co-initiator on the rate of change of light transmission throughout polymerisation and degree of conversion of model RBC formulations. Bisphenol-A diglycidyl ether dimethacrylate (bis-GMA) and triethylene glycol dimethacrylate (TEGDMA) (6:4 molar ratio) resins filled with silanized glass filler (74wt.%) and containing various photoinitiators (camphorquinone; CQ, 1-phenyl-1,2-propanedione; PPD, benzil; BZ), co-initiator types (N,N-dimethyl-p-amino benzoic acid ethyl ester; DABE, N,N-cyanoethyl methylaniline; CEMA, N,N-diethanol-p-toluidine; DEPT) and concentration (0.0-0.3% DABE) were polymerised using a halogen or LED light curing-unit (LCU) for 10, 20 and 40s. The setting reaction was monitored in real-time by measuring the light transmittance through the curing specimen and bulk degree of conversion (DC) evaluated using Fourier transform infra-red spectroscopy. Specimens containing CQ and PPD cured with the halogen LCU did not have a significant effect on DC or changes in light transmission, although a significant increase in DC was observed for CQ compared with PPD specimens cured with the LED LCU. DABE and CEMA were more effective co-initiators than DEPT. Although DC was not limited by co-initiator concentration, the absence of a co-initiator resulted in marked differences in light transmission and decreased DC throughout 40s irradiation with each LCU type. The spectral range emitted from different types of LCU and absorption characteristics of the photoinitiator chemistry of light-activated resin-based composites play a critical role in the efficiency of polymerisation.
Quality of dry-cured ham compared with quality of dry-cured shoulder.
Reina, Raquel; Sánchez del Pulgar, José; Tovar, Jorge; López-Buesa, Pascual; García, Carmen
2013-08-01
The physicochemical and sensory properties of 30 dry-cured hams and 30 dry-cured shoulders were analyzed to determine the relationships between them. The variables used to characterize both products were: compositional parameters, instrumental texture, amino acid and fatty acid composition, and sensory profile. Despite being products from the same animal and composed mainly of fat, lean, and bone, their morphological differences determine the conditions of the processing time, which produced differences between products in most of the parameters evaluated. Dry-cured shoulders showed lower moisture content and greater instrumental hardness due to their morphology and muscular structure. Besides, these samples showed lower amino acid content according to the shorter ripening time. For the same reason, the dry-cured hams showed higher moisture content, lower instrumental hardness, and higher amino acid content. However, the differences in the muscular structure did not affect the sensory characteristics, which were more related with some compositional parameters, such as chloride, moisture, and amino acid content and with the length of the curing process. © 2013 Extremadura University.
Guo, Lei; Ye, Hua; Pan, Liwei; Sun, Laifang; Ying, Binyu
2014-12-01
To investigate the clinical effect of hemoperfusion combined with hemodialysis in the treatment of severe organophosphate pesticide poisoning. Ninety-eight patients with severe organophosphate pesticide poisoning who were admitted to the emergency department of our hospital from March 2005 to September 2013 were equally divided into control group and observation group according to treatment methods. The control group was given conventional emergency treatment, while the observation group was given hemoperfusion combined with hemodialysis and the conventional emergency treatment. The clinical outcomes and complications of two groups were compared. In the control group, 35 patients were cured and 14 patients died, so the cure rate was 71.4%. In the treatment group, 46 patients were cured and 3 patients died, so the cure rate was 93.9%. The treatment group had a significantly higher cure rate than the control group (χ² = 8.611, P < 0.05). And the treatment group had significantly shorter duration of coma (P < 0.01), mean length of hospital stay (P < 0.01), and time to recovery of cholinesterase activity (P < 0.01) and a significantly reduced dose of atropine than the control group (P < 0.01). The control group had significantly more cases of urinary retention than the treatment group (18 vs. 6, χ² = 4.991, P < 0.05). And the control group had more cases of intermediate syndrome, respiratory failure, delayed neurological damage, and rebound than the treatment group. Hemoperfusion combined hemodialysis has a good clinical effect and causes fewer complications in treating severe organophosphate pesticide poisoning, so it is worthy of clinical promotion.
Turk, Tamer; Elekdag-Turk, Selma; Isci, Devrim
2007-01-01
To evaluate the effect of a self-etching primer on shear bond strengths (SBS) at the different debond times of 5, 15, 30, and 60 minutes and 24 hours. Brackets were bonded to human premolars with different etching protocols. In the control group (conventional method [CM]) teeth were etched with 37% phosphoric acid. In the study group, a self-etching primer (SEP; Transbond Plus Self Etching Primer; 3M Unitek, Monrovia, Calif) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT; 3M Unitek) and light-cured for 20 seconds in both groups. The shear bond test was performed at the different debond times of 5, 15, 30 and 60 minutes and 24 hours. Lowest SBS was attained with a debond time of 5 minutes for the CM group (9.51 MPa) and the SEP group (8.97 MPa). Highest SBS was obtained with a debond time of 24 hours for the CM group (16.82 MPa) and the SEP group (19.11 MPa). Statistically significant differences between the two groups were not observed for debond times of 5, 15, 30, or 60 minutes. However, the SBS values obtained at 24 hours were significantly different (P < .001). Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method. It is reliable to load the bracket 5 minutes after bonding using self-etching primer (Transbond Plus) with the light-cure adhesive (Transbond XT).
Preparation and properties of isotropic Nd-Fe-B bonded magnets with sodium silicate binder
NASA Astrophysics Data System (ADS)
Liu, W. Q.; Hu, R. J.; Yue, M.; Yin, Y. X.; Zhang, D. T.
2017-08-01
In present study, sodium silicate, a kind of heat-resistant binder, was used to prepare bonded Nd-Fe-B magnets with improved thermal stability and mechanical strength. Effect of curing temperature and curing time of the new binder to the magnetic properties, microstructure, and mechanical strength of the magnets was systematically investigated. Fracture surface morphology observation show that sodium silicate in bonded magnets could completely be cured at 175 °C for 40 min, and the magnets prepared under this condition exhibit optimal properties. They exhibit usable magnetic properties of Br of 4.66 kGs, Hcj of 4.84 kOe, and (BH)max of 4.06 MGOe at 200 °C. Moreover, the magnets possess high compressive strength of 63 MPa.
Tulunoglu, O; Uçtaşh, M; Alaçam, A; Omürlü, H
2000-01-01
This in vitro study evaluated the effect of dentin bonding agents in reducing microleakage after three months in Class V restorations restored with Z100 resin composite. Materials tested were three types of resin-based dentin bonding agents: a multi-step (Scotchbond Multi-Purpose); a one-step (Scotchbond One-Step); a self-etching, self-priming (Clearfil Liner Bond) and a resin-modified glass ionomer (GC Fuji Bond LC). Class V cavity preparations with occlusal margins in enamel and gingival margins in cementum were prepared both on labial and lingual surfaces of extracted premolar teeth. Restorations (two per tooth) were distributed randomly into nine test groups (n = 10) consisting of the various DBAs applied with co-cure and pre-cure techniques, and no dentin bonding as a negative control group. Samples were stored in saline for three months, thermocycled, stained with silver nitrate, then sectioned through the middle of the preparation to facilitate the removal of the composite resin restoration. For groups treated with the pre-cure technique, the differences between the enamel leakage values of SBMP-control, CFLB-control and SB1S-control subgroups were significant (p < 0.05). For enamel leakage values of groups treated with the co-cure technique, the differences between the SBMP-control, SB1S-control, CFLB-control and Fuji LC-control subgroups were significant (p < 0.05). For cementum leakage values of groups treated with pre-cure technique, the difference between the CFLB-control and the Fuji, SBMP and SB1S groups was significant (p < 0.05). No significant differences could be detected between the cementum leakage values of groups treated with the co-cure technique (p > 0.05). The differences between the values obtained with application of CFLB with the pre-cure and co-cure techniques at the cementum margins were found to be statistically significant (p = 0.02). No statistically significant differences could be detected between the pre-cure and co-cure values of the other test materials. Generally for every group, cementum microleakage values were greater than enamel microleakage values (p < 0.05). The use of Scotchbond Multi-Purpose, Scotchbond One-Step and Fuji Bond LC with the co-cure technique to decrease the application time did not cause any significant increase in microleakage. Only pre-curing using Clearfil Liner Bond provided better microleakage properties than the other pre-cured adhesives.
Chemoviscosity modeling for thermosetting resin systems, 4
NASA Technical Reports Server (NTRS)
Hou, T. H.; Huang, Joan Y. Z.
1989-01-01
An experimental study on the changes of chemorheological properties has been conducted and analyzed on commercial Hercules 3501-6 resin system cured under several isothermal conditions between 375 and 435 K. For the cure temperatures equal to or greater than 385 K, the storage modulus curing curves, G prime (t), exhibited abrupt changes in slope which occurred at various times depending on the curing temperatures and were attributed to the onset of gelation reactions. The crossover points between G prime (t) and G double prime (t) curves were observed for curing temperatures equal to or greater than 400 K. The gelation and the crossover points obtained from the chemorheological measurements, therefore, defined two characteristic resin states during cure. Approximately the same value for the degree of cure was reached by the advancement of the reaction at each of these states. The temperature dependency of the viscosities for the characteristic resin states and the rate constants of increase in moduli at different stages of curing were analyzed. Various G prime (t) and G double prime (t) isothermal curing curves were also shown to be capable of being superimposed on one another by the principle of time-temperature superposition. The resultant shift factors a sub t(t) and a Eta(T) were shown to follow the Arrhenius type relationship. Values of the activation energy suggested that the reaction kinetics, instead of the diffusion mechanism, was the limiting step in the overall resin advancement for the cure at temperatures equal to or greater than 385 K.
Use of fiber reinforced concrete for concrete pavement slab replacement : [summary].
DOT National Transportation Integrated Search
2014-03-01
Replacing cracked concrete in roadways requires : lanes to be closed and traff c disrupted. One way : to reduce road closure time is to reduce concrete : curing time. To accelerate curing time, pavement : engineers mix a very low water-cement ratio w...
Influence of light-curing mode on the cytotoxicity of resin-based surface sealants.
Wegehaupt, Florian J; Tauböck, Tobias T; Attin, Thomas; Belibasakis, Georgios N
2014-05-06
Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity. Bovine dentine discs were treated as follows: group 1: untreated, groups 2-5: Seal&Protect and groups 6-9: experimental sealer. Groups 2 and 6 were light-cured (VALO LED light-curing device) for 40 s (1000 mW/cm2), groups 3 and 7 for 10 s (1000 mW/cm2), groups 4 and 8 for 7 s (1400 mW/cm2) and groups 5 and 9 for 3 s (3200 mW/cm2). Later, materials were extracted in culture medium for 24 h, and released lactate dehydrogenase (LDH) activity as a measure of cytotoxicity was determined photometrically after cells (dental pulp cells and gingival fibroblasts) were exposed to the extracts for 24 h. Three independent experiments, for both sample preparation and cytotoxicity testing, were performed. Overall, lowest cytotoxicity was observed for the unsealed control group. No significant influence of light-curing settings on the cytotoxicity was observed (p = 0.537 and 0.838 for pulp cells and gingival fibroblasts, respectively). No significant difference in the cytotoxicity of the two sealants was observed after light-curing with same light-curing settings (group 2 vs. 6, 3 vs. 7, 4 vs. 8 and 5 vs. 9: p > 0.05, respectively). Shortening the light-curing time, while maintaining constant energy density, resulted in no higher cytotoxicity of the investigated sealants.
Dataset of producing and curing concrete using domestic treated wastewater
Asadollahfardi, Gholamreza; Delnavaz, Mohammad; Rashnoiee, Vahid; Fazeli, Alireza; Gonabadi, Navid
2015-01-01
We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m3 of cement before chlorination and then cured concrete samples made with drinking water and treated wastewater. Second, concrete samples made with 350 kg/m3 of cement with a Superplasticizer admixture made with drinking water and treated wastewater and then cured with treated wastewater. The compressive strength of all the concrete samples made with treated wastewater had a high coefficient of determination with the control concrete samples. A 28-day tensile strength of all the samples was 96–100% of the tensile strength of the control samples and the setting time was reduced by 30 min which was consistent with a ASTMC191 standard. All samples produced and cured with treated waste water did not have a significant effect on water absorption, slump and surface electrical resistivity tests. However, compressive strength at 21 days of concrete samples using 300 kg/m3 of cement in rapid freezing and thawing conditions was about 11% lower than concrete samples made with drinking water. PMID:26862577
Dataset of producing and curing concrete using domestic treated wastewater.
Asadollahfardi, Gholamreza; Delnavaz, Mohammad; Rashnoiee, Vahid; Fazeli, Alireza; Gonabadi, Navid
2016-03-01
We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m(3) of cement before chlorination and then cured concrete samples made with drinking water and treated wastewater. Second, concrete samples made with 350 kg/m(3) of cement with a Superplasticizer admixture made with drinking water and treated wastewater and then cured with treated wastewater. The compressive strength of all the concrete samples made with treated wastewater had a high coefficient of determination with the control concrete samples. A 28-day tensile strength of all the samples was 96-100% of the tensile strength of the control samples and the setting time was reduced by 30 min which was consistent with a ASTMC191 standard. All samples produced and cured with treated waste water did not have a significant effect on water absorption, slump and surface electrical resistivity tests. However, compressive strength at 21 days of concrete samples using 300 kg/m(3) of cement in rapid freezing and thawing conditions was about 11% lower than concrete samples made with drinking water.
NASA Astrophysics Data System (ADS)
Surya, I.; Hayeemasae, N.; Ginting, M.
2018-03-01
The effects of alkanolamide (ALK) addition on cure characteristics, crosslink density and degree of filler dispersion of kaolin-filled natural rubber (NR) compounds were investigated. The kaolin filler was incorporated into NR compounds with a fixed loading, 30.0 phr. The ALK was prepared from Refined Bleached Deodorized Palm Stearin (RBDPS), a waste product of cooking oil production, and diethanolamine. The ALK is an oily material and added into the filled NR compounds as a rubber additive at different loadings, 0.0, 3.0, 5.0 and 7.0. The kaolin-filled NR compounds with and without ALK were vulcanized using a semi-efficient vulcanization system. It was found that ALK decreased the scorch and cure times and improved filler dispersion of the kaolin-filled NR compounds. The higher the ALK loading, the shorter were the scorch and cure times. It was also found that ALK increased the crosslink density of kaolin-filled NR compound up to 5.0 phr of loading. Due to its oily properties, The ALK acted as an internal plasticizer which decreased the minimum torque and improved the degree of kaolin dispersion in NR phases. The higher the ALK loading; the lower the minimum torque and better the filler dispersion.
NASA Astrophysics Data System (ADS)
Tomlins, Peter H.; Rahman, Mohammed Wahidur; Donnan, Robert S.
2016-04-01
This study aimed to determine the feasibility of using optical coherence elastography to measure internal displacements during the curing phase of a light-activated, resin-based composite material. Displacement vectors were spatially mapped over time within a commercial dental composite. Measurements revealed that the orientation of cure-induced displacement vectors varied spatially in a complex manner; however, each vector showed a systematic evolution with time. Precision of individual displacements was estimated to be ˜1 to 2 μm, enabling submicrometer time-varying displacements to be detected.
Comparison of the heat generation of light curing units.
Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda
2008-02-01
The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (p<.05). The least temperature increase (11.8+/-1.3 degrees C) occurred with a LED curing unit for each tested period except for the measurement of the temperature rise using the QTH curing unit at the tenth second interval (p<.05). These results indicate the choice of light activation unit and curing time is important when polymerizing light activated resin based restorations to avoid any thermal damage to the pulp.
Wagner, R; Wendlberger, U
2000-11-10
The efficacy of moxidectin 1% injectable for cattle was evaluated in dogs and rabbits with naturally acquired sarcoptic, demodectic or psoroptic mites. Twenty-two dogs with generalised demodicosis were orally treated with 0.4mg/kg moxidectin daily. Forty-one dogs suffering from sarcoptic mange were treated with 0.2-0.25mg/kg moxidectin either orally or subcutaneously every week for three to six times. Seven rabbits were treated orally with 0.2mg/kg moxidectin twice 10 days apart. Of the 22 dogs with demodicosis, 14% were stopped treatment because of side effects, 14% were lost and of the remaining 72% all were cured (mean therapy duration 2.4 months). Thirty-seven of the sarcoptic mange-infected dogs finished treatment and were cured. In 17% of dogs, side effects were noted. All seven rabbits treated for psoroptic mange were cured and did not show any side effect. Our results indicate that moxidectin is effective and a good alternative for the treatment of demodicosis and scabies in dogs and psoroptic mange in rabbits. Side effects seem to occur more frequently if applied subcutaneously, therefore the oral route should be preferred.
A Novel Approach to Monitoring the Curing of Epoxy in Closed Tools by Use of Ultrasonic Spectroscopy
2017-01-01
The increasing use of composite materials has led to a greater demand for efficient curing cycles to reduce costs and speed up production cycles in manufacturing. One method to achieve this goal is in-line cure monitoring to determine the exact curing time. This article proposes a novel method through which to monitor the curing process inside closed tools by employing ultrasonic spectroscopy. A simple experiment is used to demonstrate the change in the ultrasonic spectrum during the cure cycle of an epoxy. The results clearly reveal a direct correlation between the amplitude and state of cure. The glass transition point is indicated by a global minimum of the reflected amplitude. PMID:29301222
Egilmez, Ferhan; Ergun, Gulfem
2012-01-01
PURPOSE The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (α=.05). RESULTS ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance (P<.001). CONCLUSION Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials. PMID:22737314
GLASS TRANSITION AND DEGREE OF CONVERSION OF A LIGHT-CURED ORTHODONTIC COMPOSITE
Sostena, Michela M. D. S.; Nogueira, Renata A.; Grandini, Carlos R.; Moraes, João Carlos Silos
2009-01-01
Objective: This study evaluated the glass transition temperature (Tg) and degree of conversion (DC) of a light-cured (Fill Magic) versus a chemically cured (Concise) orthodontic composite. Material and Methods: Anelastic relaxation spectroscopy was used for the first time to determine the Tg of a dental composite, while the DC was evaluated by infrared spectroscopy. The light-cured composite specimens were irradiated with a commercial LED light-curing unit using different exposure times (40, 90 and 120 s). Results: Fill Magic presented lower Tg than Concise (35-84°C versus 135°C), but reached a higher DC. Conclusions: The results of this study suggest that Fill Magic has lower Tg than Concise due to its higher organic phase content, and that when this light-cured composite is used to bond orthodontic brackets, a minimum energy density of 7.8 J/cm2 is necessary to reach adequate conversion level and obtain satisfactory adhesion. PMID:20027428
Efficacy of oral moxifloxacin for aerobic vaginitis.
Wang, C; Han, C; Geng, N; Fan, A; Wang, Y; Yue, Y; Zhang, H; Xue, F
2016-01-01
The purpose of this study was to investigate the therapeutic efficacy of oral moxifloxacin for aerobic vaginitis (AV). We also identified factors that are associated with therapeutic efficacy. This prospective study enrolled general gynecological outpatients at Tianjin Medical University General Hospital between September 2012 and May 2014. Women diagnosed with AV (n = 102) were recruited. All enrolled women were treated with oral moxifloxacin, 400 mg once daily for 6 days (one course). Therapeutic efficacy was evaluated based on microscopic criteria, and cure rates were calculated. Women who were microscopically improved (but not cured) received a second course of therapy. Women classified with microscopic failure were treated using other strategies. Univariate and multivariate logistic regression analysis was used to identify factors that may be associated with a cure after one course of therapy. After one course of therapy, 65.7 % (67/102) of women were cured, 29.4 % (30/102) of women were improved (but not cured), 4.9 % (5/102) of women failed to respond to the therapy. After two courses of therapy, 85.3 % (87/102) of women were cured, 9.8 % (10/102) of women were improved, 4.9 % (5/102) of women failed to respond to the therapy, and clinical improvement was achieved in additional women. In the multivariate logistic regression analysis, women with a baseline vaginal pH value of <5.0 had a 3.5-times higher chance of being cured, compared with those with a baseline vaginal pH value of ≥5.0 (OR, 3.503; 95 % CI, 1.278-9.601). Moxifloxacin is an effective therapeutic option for patients with AV. Most women with AV were cured with one course of moxifloxacin. For those with a higher vaginal pH value of ≥5.0 before treatment, two courses of therapy should be considered.
Distance and protective barrier effects on the composite resin degree of conversion
Coutinho, Margareth; Trevizam, Natália Carvalho; Takayassu, Renata Nakase; Leme, Ariene Arcas; Soares, Giulliana Panfiglio
2013-01-01
Context: The food wrap films are used to cover the tip of curing light units in order to avoid contamination and prevent damage to the light guide. However, their effects on resin polymerization are not fully known. Aims: We investigated the effects on restoration efficiency of a food wrap protective barrier used on the tip of curing light units. Materials and Methods: For each treatment, five replications were performed, a total of 60 bovine incisor. The degree of conversion (%DC) of restorations with the composite resin Opallis EA2 was evaluated using 3 curing light devices (Optilux 501, Optilight and Ultra LED) and 2 curing distances (0 and 5 mm). The composite resin was tested for restoration of cavities in bovine crowns. %DC values were measured by the Fourier transform infrared spectroscopy-attenuated total reflectance technique. Statistical Analysis Used: The data were analyzed using 3-way ANOVA and Tukey's test. Results: Use of the protective film lowered %DC (F = 4.13; P = 0.05), and the effects of curing distance were associated to the curing light device (F = 3.61; P = 0.03). Conclusions: The distance from the light curing tip and use of a translucent protective barrier on the light-cure device can both impair composite resin %DC. PMID:24015001
Pinedo, Pablo; Karreman, Hubert; Bothe, Hans; Velez, Juan; Risco, Carlos
2013-01-01
The objective was to evaluate the efficacy of a botanical product (PHYTO-MAST®) for the intra-mammary treatment of clinical mastitis (CM) in dairy cows managed in an organic system. The study involved 194 naturally occurring cases of clinical mastitis. Treatment was applied every 12 hours for 3 days and cows were evaluated for clinical cure starting on day 4. Outcomes of interest consisted of mastitis resolution at day 4, time to resolution, somatic cell score (SCS) after recovery, and bacteriological cure at 14 and 28 d after treatment. There was no significant effect on clinical mastitis resolution at day 4 for treatment compared with the control group. However, there was a faster recovery for the treatment group compared to the control group with median intervals from end of treatment to recovery of 4.6 d and 6.5 d, respectively. There was no effect on the probability of a SCS < 4 (200 000 SC/mL) after treatment. No significant effects were found for treatment on bacteriological cure at days 14 and 28. PMID:24155432
NASA Astrophysics Data System (ADS)
Elkedrouci, L.; Diao, B.; Pang, S.; Li, Y.
2018-03-01
Deterioration of reinforced concrete structures is a serious concern in the construction engineering, largely due to chloride induced corrosion of reinforcement. Chloride penetration is markedly influenced by one or several major factors at the same time such as cuing in combination with different crack widths which have spectacular effect on reinforced concrete structures. This research presents the results of an experimental investigation involving reinforced concrete beams with three different crack widths ranging from 0 to 0.2mm, curing temperatures of 20°C or 40°C and water-to-cement of 0.5. Chloride content profiles were determined under non-steady state diffusion at 20°C. Based on the obtained results, higher chloride content was obtained under condition of high curing temperature in combination with large crack more than 0.1mm and there are no significant differences between narrow crack width (less than 0.1 mm) and beams without crack (0 mm).
Rouam, Sigrid; Broët, Philippe
2013-08-01
To identify genomic markers with consistent effect on tumor dynamics across multiple cancer series, discrimination indices based on proportional hazards models can be used since they do not depend heavily on the sample size. However, the underlying assumption of proportionality of the hazards does not always hold, especially when the studied population is a mixture of cured and uncured patients, like in early-stage cancers. We propose a novel index that quantifies the capability of a genomic marker to separate uncured patients, according to their time-to-event outcomes. It allows to identify genomic markers characterizing tumor growth dynamic across multiple studies. Simulation results show that our index performs better than classical indices based on the Cox model. It is neither affected by the sample size nor the cure rate fraction. In a cross-study of early-stage breast cancers, the index allows to select genomic markers with a potential consistent effect on tumor growth dynamics. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Surya, Indra; Fauzi Siregar, Syahrul; Ismail, Hanafi
2018-03-01
Effects of alkanolamide (ALK) addition on cure characteristics, swelling behaviour and tensile properties of silica-filled natural rubber (NR)/chloroprene rubber (CR) blends were investigated. The ALK was synthesized from Refined Bleached Deodorized Palm Stearin (RBDPS) and diethanolamine, and incorporated into the silica-filled NR/CR blends as a non-toxic rubber additive. The ALK loadings were 0.0, 1.0, 3.0, 5.0 and 7.0 phr. It was found that the ALK exhibited shorter scorch and cure times and higher elongation at break of the silica-filled NR/CR blends. The ALK also exhibited higher torque differences, tensile modulus and tensile strength at a 1.0 phr of ALK loading and then decreased with further increases in the ALK loading. The swelling measurement proved that the 1.0 phr loading of ALK caused the highest degree in crosslink density of the silica-filled NR/CR blends.
CaP CURE Initiatives and Projects
Soule, Howard R
2003-01-01
CaP CURE was founded in 1993 to help find better treatments and a cure for prostate cancer. By reducing the time and complexity required to apply for funding, and by funding many first-time applicants, CaP CURE has attracted a large number of high-level investigators to the field of prostate cancer research. The organization’s Therapy Consortium meets regularly to address major issues that impede progress in clinical development of new treatments for prostate cancer. CaP CURE has also sponsored an initiative to standardize clinical trial design scenarios for the clinical state of rising prostate-specific antigen and intends to present them to the Food and Drug Administration in partnership with the National Dialogue on Cancer. Finally, CaP CURE’s efforts have resulted in a significant increase in federal funding of prostate cancer research programs. PMID:16986049
The HIV Cure Research Agenda: The Role of Mathematical Modelling and Cost-Effectiveness Analysis.
Freedberg, Kenneth A; Possas, Cristina; Deeks, Steven; Ross, Anna Laura; Rosettie, Katherine L; Di Mascio, Michele; Collins, Chris; Walensky, Rochelle P; Yazdanpanah, Yazdan
The research agenda towards an HIV cure is building rapidly. In this article, we discuss the reasons for and methodological approach to using mathematical modeling and cost-effectiveness analysis in this agenda. We provide a brief description of the proof of concept for cure and the current directions of cure research. We then review the types of clinical economic evaluations, including cost analysis, cost-benefit analysis, and cost-effectiveness analysis. We describe the use of mathematical modeling and cost-effectiveness analysis early in the HIV epidemic as well as in the era of combination antiretroviral therapy. We then highlight the novel methodology of Value of Information analysis and its potential role in the planning of clinical trials. We close with recommendations for modeling and cost-effectiveness analysis in the HIV cure agenda.
Surgical cure rates of sporadic medullary thyroid cancer in the era of calcitonin screening.
Machens, Andreas; Dralle, Henning
2016-09-01
Time trends of the extent of disease at first diagnosis and biochemical cure remain ill-defined for sporadic medullary thyroid cancer (MTC). This investigation aimed to delineate time trends and biochemical cure rates for sporadic MTC. This was an observational study of consecutive patients operated on for sporadic MTC between 1995 and 2015. Time trends of clinical and histopathological variables indicative of the extent of disease and biochemical cure were calculated for 600 patients with sporadic MTC, 322 of whom had initial neck surgery and 278 of whom had neck reoperation at a tertiary surgical center in Germany. From 1995-2000 to 2011-2015, significant declines (all P<0.001) were noted in the percentage of node-positive tumors (from 73 to 49%), mediastinal lymph node metastasis (from 21 to 6%) and distant metastasis (from 23 to 6%). These changes were paralleled by significant increases (all P<0.001) in mean patient age (from 49.1 to 57.3years) and the percentage of MTC ≤10mm (from 19 to 39%) and biochemical cure (from 28 to 62%). When only patients with primary tumors >10mm were considered, the decreasing percentage of mediastinal lymph node metastasis and distant metastasis, and rising mean patient age and biochemical cure rates remained statistically significant. Significant reductions in the extent of the disease and improved biochemical cure rates pointed toward increasing therapeutic control of sporadic MTC. The independent contribution of routine calcitonin screening to these time-dependent changes warrants more research. © 2016 European Society of Endocrinology.
Comparison of halogen, plasma and LED curing units.
Nomoto, Rie; McCabe, John F; Hirano, Susumu
2004-01-01
This study evaluated the characteristics of two kinds of recently developed light-curing unit; plasma arc and blue light emitting diodes (LED), in comparison with a conventional tungsten-halogen light-curing unit. The light intensity and spectral distribution of light from these light-curing units, the temperature rise of the bovine enamel surface and the depth of cure of composites exposed to each unit were investigated. The light intensity and depth of cure were determined according to ISO standards. The spectral distributions of emitted light were measured using a spectro-radiometer. The temperature increase induced by irradiation was measured by using a thermocouple. Generally, light intensities in the range 400-515 nm emitted from the plasma arc were greater than those from other types. Light in the UV-A region was emitted from some plasma arc units. The required irradiation times were six to nine seconds for the plasma arc units and 40 to 60 seconds for the LED units to create a depth of cure equal to that produced by the tungsten-halogen light with 20 seconds of irradiation. The temperature increased by increasing the irradiation time for every light-curing unit. The temperature increases were 15 degrees C to 60 degrees C for plasma arc units, around 15 degrees C for a conventional halogen unit and under 10 degrees C for LED units. Both the plasma arc and LED units required longer irradiation times than those recommended by their respective manufacturers. Clinicians should be aware of potential thermal rise and UV-A hazard when using plasma arc units.
Polyacrylonitrile/Carbon Nanotube Composite: Precursor for Next Generation Carbon Fiber
2010-02-23
difficult to get the accurate time for the end of reactions. The curing process of thermosetting materials has been widely studied by investigating...Ramis X, Cadenato A, Morancho JM, Salla JM. Curing of a thermosetting powder coating by means of DMTA, TMA and DSC. Polymer. 2003;44(7):2067-79. [17...Cadenato A, Salla JM, Ramis X, Morancho JM, Marroyo LM, Martin JL. Determination of gel and vitrification times of thermoset curing process by means of
Kong, Yaning; Wang, Peiming; Liu, Shuhua; Zhao, Guorong; Peng, Yu
2016-01-01
In order to investigate the effects of microwave curing on the microstructure of the interfacial transition zone of mortar prepared with a composite binder containing glass powder and to explain the mechanism of microwave curing on the improvement of compressive strength, in this study, the compressive strength of mortar under microwave curing was compared against mortar cured using (a) normal curing at 20 ± 1 °C with relative humidity (RH) > 90%; (b) steam curing at 40 °C for 10 h; and (c) steam curing at 80 °C for 4 h. The microstructure of the interfacial transition zone of mortar under the four curing regimes was analyzed by Scanning electron microscopy (SEM). The results showed that the improvement of the compressive strength of mortar under microwave curing can be attributed to the amelioration of the microstructure of the interfacial transition zone. The hydration degree of cement is accelerated by the thermal effect of microwave curing and Na+ partially dissolved from the fine glass powder to form more reticular calcium silicate hydrate, which connects the aggregate, calcium hydroxide, and non-hydrated cement and glass powder into a denser integral structure. In addition, a more stable triangular structure of calcium hydroxide contributes to the improvement of compressive strength. PMID:28773854
Kong, Yaning; Wang, Peiming; Liu, Shuhua; Zhao, Guorong; Peng, Yu
2016-08-27
In order to investigate the effects of microwave curing on the microstructure of the interfacial transition zone of mortar prepared with a composite binder containing glass powder and to explain the mechanism of microwave curing on the improvement of compressive strength, in this study, the compressive strength of mortar under microwave curing was compared against mortar cured using (a) normal curing at 20 ± 1 °C with relative humidity (RH) > 90%; (b) steam curing at 40 °C for 10 h; and (c) steam curing at 80 °C for 4 h. The microstructure of the interfacial transition zone of mortar under the four curing regimes was analyzed by Scanning electron microscopy (SEM). The results showed that the improvement of the compressive strength of mortar under microwave curing can be attributed to the amelioration of the microstructure of the interfacial transition zone. The hydration degree of cement is accelerated by the thermal effect of microwave curing and Na⁺ partially dissolved from the fine glass powder to form more reticular calcium silicate hydrate, which connects the aggregate, calcium hydroxide, and non-hydrated cement and glass powder into a denser integral structure. In addition, a more stable triangular structure of calcium hydroxide contributes to the improvement of compressive strength.
Gamero-Negrón, Rafael; García, Carmen; Reina, Raquel; Sánchez Del Pulgar, José
2018-09-01
The aim of this study was to assess the effect of immune-spaying on sensory characteristics and the volatile organic compound (VOC) profile of dry-cured shoulders and loins by comparing Iberian × Duroc surgically spayed females, immune-spayed females and entire females. VOC profile of dry-cured shoulders was not significantly affected by the reproductive status, probably due to the large heterogeneity of dry-cured shoulders as a product. Correspondingly, dry-cured shoulders showed little differences among treatment groups, with better scores for marbling, hardness and chewiness attributes in the immune-spayed females. Dry-cured loin sensory traits such as brightness, marbling, chewiness and juiciness, presented better scores in immune-spayed females. Moreover, dry-cured loins showed a higher homogeneity that allowed the effects of spaying to be observed, thus the Principal Component Analysis performed on VOC profile data indicated a better separation of samples among treatment groups. Consequently, immune-spaying could be a viable alternative to surgical spaying from the point of view of meat quality. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effects of Using Pozzolan and Portland Cement in the Treatment of Dispersive Clay
Vakili, A. H.; Selamat, M. R.; Moayedi, H.
2013-01-01
Use of dispersive clay as construction material requires treatment such as by chemical addition. Treatments to dispersive clay using pozzolan and Portland cement, singly and simultaneously, were carried out in this study. When used alone, the optimum amount of pozzolan required to treat a fully dispersive clay sample was 5%, but the curing time to reduce dispersion potential, from 100% to 30% or less, was 3 month long. On the other hand, also when used alone, a 3% cement content was capable of reducing dispersion potential to almost zero percent in only 7 days; and a 2% cement content was capable of achieving similar result in 14 days. However, treatment by cement alone is costly and could jeopardize the long term performance. Thus, a combined 5% pozzolan and 1.5% cement content was found capable of reducing dispersion potential from 100% to zero percent in 14 days. The results indicate that although simultaneous treatment with pozzolan and cement would extend the required curing time in comparison to treatment by cement alone of a higher content, the task could still be carried out in a reasonable period of curing time while avoiding the drawbacks of using either pozzolan or cement alone. PMID:23864828
Marzocca, A J; Cerveny, S; Salgueiro, W; Somoza, A; Gonzalez, L
2002-02-01
An experimental investigation was performed to study the effect on the free volume of the advance of the cross-linking reaction in a copolymer of styrene butadiene rubber by sulfur vulcanization. The dynamic modulus and loss tangent were evaluated over samples cured for different times at 433 K by dynamic mechanical tests over a range of frequencies between 5 and 80 Hz at temperatures between 200 and 300 K. Using the William-Landel-Ferry relationship, master curves were obtained at a reference temperature of 298 K and the coefficients c(0)(1) and c(0)(2) were evaluated. From these parameters the dependence of the free volume on the cure time is obtained. Positron annihilation lifetime spectroscopy was also used to estimate the size and number density of free volume sites in the material. The spectra were analyzed in terms of continuous distributions of free volume size. The results suggest an increase of the lower free volume size when cross linking takes place. Both techniques give similar results for the dependence of free volume on the time of cure of the polymer.
Effects of using pozzolan and Portland cement in the treatment of dispersive clay.
Vakili, A H; Selamat, M R; Moayedi, H
2013-01-01
Use of dispersive clay as construction material requires treatment such as by chemical addition. Treatments to dispersive clay using pozzolan and Portland cement, singly and simultaneously, were carried out in this study. When used alone, the optimum amount of pozzolan required to treat a fully dispersive clay sample was 5%, but the curing time to reduce dispersion potential, from 100% to 30% or less, was 3 month long. On the other hand, also when used alone, a 3% cement content was capable of reducing dispersion potential to almost zero percent in only 7 days; and a 2% cement content was capable of achieving similar result in 14 days. However, treatment by cement alone is costly and could jeopardize the long term performance. Thus, a combined 5% pozzolan and 1.5% cement content was found capable of reducing dispersion potential from 100% to zero percent in 14 days. The results indicate that although simultaneous treatment with pozzolan and cement would extend the required curing time in comparison to treatment by cement alone of a higher content, the task could still be carried out in a reasonable period of curing time while avoiding the drawbacks of using either pozzolan or cement alone.
Analysis of rheological properties of bone cements.
Nicholas, M K D; Waters, M G J; Holford, K M; Adusei, G
2007-07-01
The rheological properties of three commercially available bone cements, CMW 1, Palacos R and Cemex ISOPLASTIC, were investigated. Testing was undertaken at both 25 and 37 degrees C using an oscillating parallel plate rheometer. Results showed that the three high viscosity cements exhibited distinct differences in curing rate, with CMW 1 curing in 8.7 min, Palacos R and Cemex ISOPLASTIC in 13 min at 25 degrees C. Furthermore it was found that these curing rates were strongly temperature dependent, with curing rates being halved at 37 degrees C. By monitoring the change of viscosity with time over the entire curing process, the results showed that these cements had differing viscosity profiles and hence exhibit very different handling characteristics. However, all the cements reached the same maximum viscosity of 75 x 10(3) Pa s. Also, the change in elastic/viscous moduli and tan delta with time, show the cements changing from a viscous material to an elastic solid with a clear peak in the viscous modulus during the latter stages of curing. These results give valuable information about the changes in rheological properties for each commercial bone cement, especially during the final curing process.
Pérez-Palacios, Trinidad; Ruiz, Jorge; Martín, Diana; Grau, Raúl; Antequera, Teresa
2010-04-15
This work was designed to study the effect of pre-cure freezing of raw thighs from Iberian pigs on the profile of volatile compounds during the processing of hams. Generation of volatile compounds during Iberian ham processing was similar in both pre-cure frozen and refrigerated hams, the main differences being at the final stage. The levels of 2-methylbutanal, 2-methyl-1-butanol, 2,3-butanediol and 2-heptanol were significantly higher in dry-cured hams that were pre-cure frozen than in refrigerated ones, whereas the content of most detected esters was statistically lower in pre-cure frozen than in refrigerated hams. The effect of pre-cure freezing of Iberian ham on the profile of volatile compounds during ripening was not remarkable. Few differences were found in the final product, which would not greatly modify the aroma and flavour features of the dry-cured hams. (c) 2010 Society of Chemical Industry.
Cherroud, Sanâa; Cachaldora, Aida; Fonseca, Sonia; Laglaoui, Amin; Carballo, Javier; Franco, Inmaculada
2014-10-01
The objective of this work was to define a simple technological process for dry-cured Halal goat meat elaboration. The aims of this study were to analyze physicochemical parameters and to enumerate the microbial population at the end of the different manufacturing processes (two salting times and the addition of olive oil and paprika covering) on 36 units of meat product. A total of 532 strains were isolated from several selective culture media and then identified using classical and molecular methods. In general, salt effect and the addition of olive oil and paprika were significant for all the studied microbial groups as well as on NaCl content and water activity. Molecular analysis proves that staphylococci, especially Staphylococcus xylosus and Staphylococcus equorum, were the most common naturally occurring microbiota. The best manufacturing process would be obtained with a longer salting time and the addition of the olive oil and paprika covering. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gardner, Timothy B.; Hill, David R.
2001-01-01
Giardia lamblia is both the most common intestinal parasite in the United States and a frequent cause of diarrheal illness throughout the world. In spite of its recognition as an important human pathogen, there have been relatively few agents used in therapy. This paper discusses each class of drugs used in treatment, along with their mechanism of action, in vitro and clinical efficacy, and side effects and contraindications. Recommendations are made for the preferred treatment in different clinical situations. The greatest clinical experience is with the nitroimidazole drugs, i.e., metronidazole, tinidazole, and ornidazole, which are highly effective. A 5- to 7-day course of metronidazole can be expected to cure over 90% of individuals, and a single dose of tinidazole or ornidazole will cure a similar number. Quinacrine, which is no longer produced in the United States, has excellent efficacy but may be poorly tolerated, especially in children. Furazolidone is an effective alternative but must be administered four times a day for 7 to 10 days. Paromomycin may be used during early pregnancy, because it is not systematically absorbed, but it is not always effective. Patients who have resistant infection can usually be cured by a prolonged course of treatment with a combination of a nitroimidazole with quinacrine. PMID:11148005
Curing dynamics of photopolymers measured by single-shot heterodyne transient grating method.
Arai, Mika; Fujii, Tomomi; Inoue, Hayato; Kuwahara, Shota; Katayama, Kenji
2013-01-01
The heterodyne transient grating (HD-TG) method was first applied to the curing dynamics measurement of photopolymers. The curing dynamics for various monomers including an initiator (2.5 vol%) was monitored optically via the refractive index change after a single UV pulse irradiation. We could obtain the polymerization time and the final change in the refractive index, and the parameters were correlated with the viscosity, molecular structure, and reaction sites. As the polymerization time was longer, the final refractive change was larger, and the polymerization time was explained in terms of the monomer properties.
Method of controlling a resin curing process. [for fiber reinforced composites
NASA Technical Reports Server (NTRS)
Webster, Charles Neal (Inventor); Scott, Robert O. (Inventor)
1989-01-01
The invention relates to an analytical technique for controlling the curing process of fiber-reinforced composite materials that are formed using thermosetting resins. The technique is the percent gel method and involves development of a time-to-gel equation as a function of temperature. From this equation a rate-of-gel equation is then determined, and a percent gel is calculated which is the product of rate-of-gel times time. Percent gel accounting is used to control the proper pressure application point in an autoclave cure process to achieve desired properties in a production composite part.
Spearing, Natalie M; Gyrd-Hansen, Dorte; Pobereskin, Louis H; Rowell, David S; Connelly, Luke B
2012-09-01
This study examines whether the lure of injury compensation prompts whiplash claimants to overstate their symptoms. Claim settlement is the intervention of interest, as it represents the point at which there is no further incentive to exaggerate symptoms, and neck pain at 24 months is the outcome of interest. Longitudinal data on neck pain scores and timing of claim settlement were regressed, controlling for the effect of time on recovery, to compare outcomes in claimants who had and had not settled their compensation claims. The results show clearly that removing the financial incentive to over-report symptoms has no effect on self-reported neck pain in a fault-based compensation scheme, and this finding concurs with other studies on this topic. Policy decisions to limit compensation in the belief that claimants systematically misrepresent their health status are not supported empirically Claimants do not appear to be "cured by a verdict".
Seahorses - a source of traditional medicine.
Kumaravel, K; Ravichandran, S; Balasubramanian, T; Sonneschein, Leonard
2012-01-01
Wild marine organisms have been used in the discovery and development of traditional and allopathic medical treatments for a long time. Seahorses, a syngnathidae fish, are one of the important candidate organisms which have been used in Chinese traditional medicine from time immemorial. It is believed that seahorses have the potential to cure infertility, baldness, asthma and arthritis. An authentic research work on the biomedical validation of seahorses proved that they have the ability to cure arthritis and its associated inflammation. A Cathepsin-derived peptide from the seahorse species of Hippocampus kuda proved to be effective in chondrocyte cells and its associated impaired arthritis inflammation. Apart from this, seahorses have a putative free radical scavenging effect in controlling the ageing process. More authentic research is needed in order to validate the biomedical potential. This article highlights the role of seahorses' value in traditional medicine and their biomedical properties.
East, J M; DuQuesnay, D
2007-12-01
Operating time for idiopathic hydroceles and epididymal cysts is scarce as these conditions compete with an increasing caseload of more consequential surgical disease. Therapy is often relegated to repeated aspiration. Sclerotherapy appears to be effective in a majority of published trials, but comparative effectiveness, efficacy and safety of most agents, including phenol versus tetracycline, has not been established A deliberate strategy of re-treatment until cure is not universally practised, with surgery still being offered after single-treatment failures. Two trials, the first consisting of 53 scrotal cysts treated with 5% phenol-in-water and the second, 42 cysts treated with tetracycline, are compared for effectiveness, efficacy and safety of sclerotherapy per se and of re-treatment. Intention-to-treat analysis yields similar cure rates (no re-accumulation three months after last injection) for phenol and tetracycline (83% and 81% respectively, p = 0.8). Per-protocol analysis also yields similar cure rates (100% and 97% respectively, p = 0.26) and mean number of injections to cure (1.34 and 1.12 respectively, p = 0.069), with range 1-4 and 1-3 respectively. Severe pain following tetracycline injection required administration of pre-injection cord block. Other complications occurred equally (25% and 25.7% respectively, p = 0.94) and were trivial except for one case of chronic haematocele treated by orchiectomy in the tetracycline group. Phenol (5%) and tetracycline are equally efficacious sclerosants for idiopathic scrotal cysts, achieving almost 100% cure with re-treatment and matching the efficacy of surgery. Concern about post-treatment fertility applies equally to surgery and demands informed consent for both modalities.
Monitoring cure of composite resins using frequency dependent electromagnetic sensing techniques
NASA Technical Reports Server (NTRS)
Kranbuehl, D. E.; Hoff, M. S.; Loos, A. C.; Freeman, W. T., Jr.; Eichinger, D. A.
1988-01-01
A nondestructive in situ measurement technique has been developed for monitoring and measuring the cure processing properties of composite resins. Frequency dependent electromagnetic sensors (FDEMS) were used to directly measure resin viscosity during cure. The effects of the cure cycle and resin aging on the viscosity during cure were investigated using the sensor. Viscosity measurements obtained using the sensor are compared with the viscosities calculated by the Loos-Springer cure process model. Good overall agreement was obtained except for the aged resin samples.
Xia, Z G; Zhou, X L; Kong, W C; Li, X Z; Song, J H; Fang, L S; Hu, D L; Cai, C; Tang, Y Z; Yu, Y X; Wang, C H; Xu, Q L
2018-03-20
Objective: To explore the influence of three-level collaboration network of pediatric burns in Anhui province on treatment effects of burn children. Methods: The data of medical records of pediatric burn children transferred from Lu'an People's Hospital and Fuyang People's Hospital to the First Affiliated Hospital of Anhui Medical University from January 2014 to December 2015 and January 2016 to September 2017 (before and after establishing three-level collaboration network of pediatric burns treatment) were analyzed: percentage of transferred burn children to hospitalized burn children in corresponding period, gender, age, burn degree, treatment method, treatment result, occurrence and treatment result of shock, and operative and non-operative treatment time and cost. Rehabilitation result of burn children transferred back to local hospitals in 2016 and 2017. Data were processed with t test, chi-square test, Mann-Whitney U test, and Fisher's exact test. Results: (1) Percentage of burn children transferred from January 2014 to December 2015 was 34.3% (291/848) of the total number of hospitalized burn children in the same period of time, which was close to 30.4% (210/691) of burn children transferred from January 2016 to September 2017 ( χ (2)=2.672, P >0.05). (2) Gender, age, burn degree, and treatment method of burn children transferred from the two periods of time were close ( χ (2)=3.382, Z =-1.917, -1.911, χ (2)=3.133, P >0.05). (3) Cure rates of children with mild, moderate, and severe burns transferred from January 2016 to September 2017 were significantly higher than those of burn children transferred from January 2014 to December 2015 ( χ (2)=11.777, 6.948, 4.310, P <0.05). Cure rates of children with extremely severe burns transferred from the two periods of time were close ( χ (2)=1.181, P >0.05). (4) Children with mild and moderate burns transferred from the two periods of time were with no shock. The incidence of shock of children with severe burns transferred from January 2014 to December 2015 was 6.0% (4/67), and 3 children among them were cured. The incidence of shock of children with severe burns transferred from January 2016 to September 2017 was 3.9% (2/51), and both children were cured. The incidences and cures of shock of children with severe burns transferred from the two periods of time were close ( χ (2)=0.006, P >0.05). Incidence of shock of children with extremely severe burns transferred from January 2014 to December 2015 was 57.1% (32/56), significantly higher than that of burn children transferred from January 2016 to September 2017 [34.5% (10/29), χ (2)=3.925, P <0.05]. Shock of 25 children with extremely severe burns transferred from January 2014 to December 2015 were cured, and shock of 9 children with extremely severe burns transferred from January 2016 to September 2017 were cured. The cures of shock of children with extremely severe burns transferred from the two periods of time were close ( χ (2)=0.139, P >0.05). (5) Time of operative treatment of children with moderate, severe, and extremely severe burns transferred from January 2014 to December 2015 was obviously longer than that of burn children transferred from January 2016 to September 2017 ( t =2.335, 2.065, 2.310, P <0.05). Time of operative treatment of children with mild burns transferred from the two periods of time was close ( Z =-0.417, P >0.05). Costs of operative treatment of children with moderate and severe burns transferred from January 2014 to December 2015 were significantly more than those of burn children transferred from January 2016 to September 2017 ( Z =-3.324, t =2.167, P <0.05). Costs of operative treatment of children with mild and extremely severe burns transferred from the two periods of time were close ( t =0.627, 0.808, P >0.05). (6)Time of non-operative treatment of children with mild, moderate, and severe burns transferred from January 2014 to December 2015 was obviously longer than that of burn children transferred from January 2016 to September 2017 ( t =2.335, Z =-2.095, t =2.152, P <0.05). Time of non-operative treatment of children with extremely severe burns transferred from the two periods of time was close ( t =0.450, P >0.05). Costs of non-operative treatment of children with moderate and severe burns transferred from January 2014 to December 2015 were obviously higher than those of burn children transferred from January 2016 to September 2017 ( Z =-2.164, t =2.040, P <0.05). Costs of non-operative treatment of children with mild and extremely severe burns transferred from the two periods of time were close ( t =0.146, 1.235, P >0.05). (7) Sixty-seven burn children transferred from January 2016 to September 2017 were transferred back to local hospitals for rehabilitation under the guidance of experts of the First Affiliated Hospital of Anhui Medical University, with 25 patients in 2016 and 42 patients in 2017. Effective rehabilitation rates of burn children transferred back to local hospitals for rehabilitation in 2016 and 2017 were both 100%. Conclusions: The three-level collaboration network of pediatric burns treatment in Anhui province can effectively increase cure rate of children with mild, moderate, and severe burns, reduce incidence of shock of children with extremely severe burns, shorten time of operative treatment of burn children with moderate, severe, and extremely severe burns, and time of non-operative treatment of children with mild, moderate, and severe burns, reduce treatment costs of children with moderate and severe burns, and improve rehabilitation effectiveness of children transferred from Lu'an People's Hospital and Fuyang People's Hospital to the the First Affiliated Hospital of Anhui Medical University.
Development and evaluation of epoxidized soybean oil-based polymers
NASA Astrophysics Data System (ADS)
Juangvanich, Nuanpen
Epoxidized Soybean Oil (ESO) based polymers were developed using diamine curing agents and BF3:NH2C2H5 as catalyst. Reactions involved the curing process were explored and monitored by DSC and IR analysis. Amine-epoxy addition reactions governed the main curing reaction at the temperature range of 60--235°C, and the supplementary reactions at higher temperatures were either homopolymerization or etherification reaction. In the aliphatic curing reactions, the epoxy-rich system favored the supplementary reactions at high temperature, however, ESO cured with 1,6 hexanediamine (HDA) always produced the high temperature reaction products, due to some side reactions and the high volatile nature. The curing reaction with aromatic diamines produced inherent rigidity to the cured ESO network, which decreased the high temperature reactions. The system cured with a short aromatic diamine, 1,4-phenyldiamine (PDA), produced a small extent of high temperature reaction, as well. It was believed that the long length diamine with wide separation of the two amines underwent an intermolecular cross-linking reaction, and derived better properties than the shorter diamine. A post-cure process was used to improve the final polymer properties by increasing the temperature after the initial curing reaction was quenched due to gelation. Extending the time of post-curing did not significantly improve properties of the final ESO polymers. Exposing the cured samples at 180°C for longer than 12 hours decreased the properties of the cured material, due to thermal strain generating in the network structure. To increase time efficiency, short heat cycles were performed by post-curing right after gelation, and the cured ESO polymer had tensile strength of 32 MPa, modulus 750 MPa and toughness 1.3 MPa. With the introduction of EPON 828, the mechanical properties of a new ESO polymer improved; having strength above 40 MPa, modulus great than 1,000 MPa, and Tg higher than 40°C. Finally, a rice hull particleboard was developed using the cured ESO resin as adhesive, and the board had strength comparable to the National Bureau of Standards minimum requirement for particleboard. A 35 wt % of ESO resin imparted the highest strength for the rice hull board, with a value of 15.5 MPa.
Electron beam curing — taking good ideas to the manufacturing floor
NASA Astrophysics Data System (ADS)
Saunders, C.; Lopata, V.; Barnard, J.; Stepanik, T.
2000-03-01
Acsion is exploiting several emerging electron beam EB applications ranging from composite curing and repair to viscose manufacturing. EB curing of composite structures offers several advantages: significantly reduced curing times; improvements in part quality and performance; reduced environmental and health concerns; improvements in material handling; and reduced overall manufacturing costs compared to thermal curing. The aerospace industry is developing EB technology in all of their market sectors, including military aviation and space products. Some specific products include cryogenic fuel tanks, improved canopy frames for jet aircraft, and the all-composite military aircraft. This paper discusses each of these opportunities.
Li, Na; Takagaki, Tomohiro; Sadr, Alireza; Waidyasekera, Kanchana; Ikeda, Masaomi; Chen, Jihua; Nikaido, Toru; Tagami, Junji
2011-12-01
To evaluate the microtensile bond strength (μTBS) and acid-base resistant zone (ABRZ) of two dualcuring core systems to dentin using four curing modes. Sixty-four caries-free human molars were randomly divided into two groups according to two dual-curing resin core systems: (1) Clearfil DC Core Automix; (2) Estelite Core Quick. For each core system, four different curing modes were applied to the adhesive and core resin: (1) dual-cured and dual-cured (DD); (2) chemically cured and dual-cured (CD); (3) dual-cured and chemically cured (DC); (4) chemically cured and chemically cured (CC). The specimens were sectioned into sticks (n = 20 for each group) for the microtensile bond test. μTBS data were analyzed using two-way ANOVA and the Dunnett T3 test. Failure patterns were examined with scanning electron microscopy (SEM) to determine the proportion of each mode. Dentin sandwiches were produced and subjected to an acid-base challenge. After argon-ion etching, the ultrastructure of ABRZ was observed using SEM. For Clearfil DC Core Automix, the μTBS values in MPa were as follows: DD: 29.1 ± 5.4, CD: 21.6 ± 5.6, DC: 17.9 ± 2.8, CC: 11.5 ± 3.2. For Estelite Core Quick, they were: DD: 48.9 ±5.7, CD: 20.5 ± 4.7, DC: 41.4 ± 8.3, CC: 19.1 ± 6.0. The bond strength was affected by both material and curing mode, and the interaction of the two factors was significant (p < 0.001). Within both systems, there were significant differences among groups, and the DD group showed the highest μTBS (p < 0.05). ABRZ morphology was not affected by curing mode, but it was highly adhesive-material dependent. The curing mode of dual-curing core systems affects bond strength to dentin, but has no significant effect on the formation of ABRZ.
Rondeau, Virginie; Schaffner, Emmanuel; Corbière, Fabien; Gonzalez, Juan R; Mathoulin-Pélissier, Simone
2013-06-01
Owing to the natural evolution of a disease, several events often arise after a first treatment for the same subject. For example, patients with a primary invasive breast cancer and treated with breast conserving surgery may experience breast cancer recurrences, metastases or death. A certain proportion of subjects in the population who are not expected to experience the events of interest are considered to be 'cured' or non-susceptible. To model correlated failure time data incorporating a surviving fraction, we compare several forms of cure rate frailty models. In the first model already proposed non-susceptible patients are those who are not expected to experience the event of interest over a sufficiently long period of time. The other proposed models account for the possibility of cure after each event. We illustrate the cure frailty models with two data sets. First to analyse time-dependent prognostic factors associated with breast cancer recurrences, metastases, new primary malignancy and death. Second to analyse successive rehospitalizations of patients diagnosed with colorectal cancer. Estimates were obtained by maximization of likelihood using SAS proc NLMIXED for a piecewise constant hazards model. As opposed to the simple frailty model, the proposed methods demonstrate great potential in modelling multivariate survival data with long-term survivors ('cured' individuals).
Kaczmarska, Karolina; Grabowska, Beata; Bobrowski, Artur; Cukrowicz, Sylwia
2018-04-24
Strength properties of the microwave cured molding sands containing binders in a form of the aqueous solution of sodium carboxymethyl starch (CMS-Na) are higher than the same molding composition cured by conventional heating. Finding the reason of this effect was the main purpose in this study. Structural changes caused by both physical curing methods of molding sands systems containing mineral matrix (silica sand) and polymer water-soluble binder (CMS-Na) were compared. It was shown, by means of the FT-IR spectroscopic studies, that the activation of the polar groups in the polymer macromolecules structure as well as silanol groups on the mineral matrix surfaces was occurred in the microwave radiation. Binding process in microwave-cured samples was an effect of formation the hydrogen bonds network between hydroxyl and/or carbonyl groups present in polymer and silanol groups present in mineral matrix. FT-IR studies of structural changes in conventional and microwave cured samples confirm that participation of hydrogen bonds is greater after microwave curing than conventional heating. Copyright © 2018 Elsevier B.V. All rights reserved.
HIV cure research in South Africa: a preliminary exploration of stakeholder perspectives.
Moodley, Keymanthri; Staunton, Ciara; de Roubaix, Malcolm; Cotton, Mark
2016-01-01
Innovative strategies for HIV cure are in development and research studies are being designed and planned globally. South Africa is no exception. However, little is known about stakeholders' knowledge, understanding and expectations of future cure research. This study aimed to obtain in-depth qualitative insights into stakeholder perspectives at this formative stage of HIV cure research. Fifteen stakeholders were interviewed in an HIV research clinic in the Western Cape, South Africa with their consent. Interviews were transcribed verbatim and analysed using thematic content analysis. Broad themes that emerged included the meaning of cure, awareness of HIV cure research, risks and benefits of such research. General awareness and understanding of HIV cure research was lower than expected. Some participants expressed a fatalistic attitude to HIV and described it as an "end-time illness" with no prospect of cure. In general, HIV cure research was regarded as risky - biologically psychologically and socially. If study designs were to include treatment interruption, participants would comply only if success was guaranteed. Given these perceptions of HIV cure research, significant challenges to consent processes and participant recruitment can be anticipated. Authentic community engagement and intensive educational interventions will be necessary prior to future cure research in South Africa.
Stedman, Margaret R; Feuer, Eric J; Mariotto, Angela B
2014-11-01
The probability of cure is a long-term prognostic measure of cancer survival. Estimates of the cure fraction, the proportion of patients "cured" of the disease, are based on extrapolating survival models beyond the range of data. The objective of this work is to evaluate the sensitivity of cure fraction estimates to model choice and study design. Data were obtained from the Surveillance, Epidemiology, and End Results (SEER)-9 registries to construct a cohort of breast and colorectal cancer patients diagnosed from 1975 to 1985. In a sensitivity analysis, cure fraction estimates are compared from different study designs with short- and long-term follow-up. Methods tested include: cause-specific and relative survival, parametric mixture, and flexible models. In a separate analysis, estimates are projected for 2008 diagnoses using study designs including the full cohort (1975-2008 diagnoses) and restricted to recent diagnoses (1998-2008) with follow-up to 2009. We show that flexible models often provide higher estimates of the cure fraction compared to parametric mixture models. Log normal models generate lower estimates than Weibull parametric models. In general, 12 years is enough follow-up time to estimate the cure fraction for regional and distant stage colorectal cancer but not for breast cancer. 2008 colorectal cure projections show a 15% increase in the cure fraction since 1985. Estimates of the cure fraction are model and study design dependent. It is best to compare results from multiple models and examine model fit to determine the reliability of the estimate. Early-stage cancers are sensitive to survival type and follow-up time because of their longer survival. More flexible models are susceptible to slight fluctuations in the shape of the survival curve which can influence the stability of the estimate; however, stability may be improved by lengthening follow-up and restricting the cohort to reduce heterogeneity in the data. Published by Oxford University Press 2014.
Paltiel, A. David; Zheng, Amy; Weinstein, Milton C.; Gaynes, Melanie R.; Wood, Robin; Freedberg, Kenneth A.; Sax, Paul E.
2017-01-01
Abstract Background. Reports of a single case of human immunodeficiency virus (HIV) eradication suggest that elimination of HIV from individuals is possible. Anticipating both increased research funding and the development of effective, durable cure technologies, we describe the circumstances under which a cure might improve survival and be cost-effective in South Africa. Methods. We adapted a simulation model comparing a hypothetical cure strategy (“Cure”) to the standard of care, lifetime antiretroviral therapy (“LifetimeART”) among adherent South Africans (58% female; mean age 33.8 years; mean CD4 257/µL; virologic suppression ≥1 year). We portrayed cure as a single intervention, producing sustained viral eradication without ART. We considered both a plausible, more imminently achievable “Baseline Scenario” and a more aspirational “Optimistic Scenario”. Inputs (Baseline/Optimistic) included the following: 50%/75% efficacy; 0.6%/0.0% fatal toxicity; 0.37%/0.085% monthly relapse over 5 years (0.185%/0.0425% per month thereafter); and $2000/$500 cost. These inputs were varied extensively in sensitivity analysis. Results. At baseline, Cure was “dominated,” yielding lower discounted life expectancy (19.31 life-years [LY] vs 19.37 LY) and greater discounted lifetime costs ($13 800 vs $13 700) than LifetimeART. Under optimistic assumptions, Cure was “cost-saving,” producing greater survival (19.91 LY) and lower lifetime costs ($11 000) than LifetimeART. Findings were highly sensitive to data assumptions, leaving little middle ground where a tradeoff existed between improved survival and higher costs. Conclusions. Only under the most favorable performance assumptions will an HIV cure strategy prove clinically and economically justifiable in South Africa. The scientific pursuit of a cure should not undermine continued expansions of access to proven, effective, and cost-effective ART. PMID:28680903
Huang, Lan; Cronin, Kathleen A; Johnson, Karen A; Mariotto, Angela B; Feuer, Eric J
2008-05-15
The objective of the current study was to investigate the long-term impact of treatment advances on the survival of patients with late-stage ovarian, colorectal (American Joint Committee on Cancer stage III, men), and testicular cancers by estimating the increase in the percentage cured from their disease and the change in survival time of uncured patients. Cause-specific survival data from 1973 to 2000 were obtained from the Surveillance, Epidemiology, and End Results Program. Survival cure models were fit and were used to estimate the gain in life expectancy (GLE) attributed to an increase in the fraction of cured patients and to prolonged survival among noncured patients. Treatment improvement for ovarian cancer resulted in a total GLE of 2 years, and 80% of that GLE was because of an extension of survival time in uncured patients (from 0.9 years to 2.1 years) rather than an increased cure fraction (from 12% to 14%). In contrast, the cure rate rose from 29% to 47% for colorectal cancer, representing 82% of a 2.8-year GLE, and from 23% to 81% for testicular cancer, representing 100% of a 24-year GLE. The current results suggested that treatment benefits for testicular and colorectal cancer in men with late-stage disease primarily are the result of increases in cure fraction, whereas survival gains for ovarian cancer occur despite persisting disease. Cure models, in combination with population-level data, provide insight into how treatment advances are changing survival and ultimately impacting mortality. Survival patterns reflect the underlying biology of response to cancer treatment and suggest promising directions for future research.
40 CFR 63.3965 - How do I determine the emission capture system efficiency?
Code of Federal Regulations, 2010 CFR
2010-07-01
...; coating solvent flash-off, curing, and drying occurs within the capture system; and the removal or... spray booth and a curing oven. (b) Measuring capture efficiency. If the capture system does not meet... surface preparation activities and drying and curing time. (c) Liquid-to-uncaptured-gas protocol using a...
NASA Astrophysics Data System (ADS)
Pang, Xueyu
This dissertation mainly focuses on studying the fundamental hydration kinetics and mechanisms of Portland cement as well as the effects of curing temperature and pressure on its various properties. An innovative test apparatus has been developed in this study to cure and test cement paste specimens under in-situ conditions, such as down-hole in oil wells with high temperature and high pressure. Two series of tests were performed using cement pastes prepared with four different classes of oilwell cement (namely Class A, C, G, and H cements). Specimens in groups of four were cured at temperatures ranging from ambient to 60 °C and pressures ranging from 0.69 to 51.7 MPa for a period of 48 or 72 hours. The density and w/c ratio of the specimens at the time of casting as well as at the end of the curing period were recorded. Total chemical shrinkage of the cement paste was measured continuously during the entire hydration period while tensile strength was obtained at the end of the curing period using both water pressure and splitting tension test methods. Due to capacity limitations of the test equipment, in-situ tensile strength was obtained for only one test series with a highest curing pressure of 13.1 MPa. Specimens from the other test series were depressurized before the tensile strength tests. Chemical shrinkage test is an important method of measuring cement hydration kinetics in that the normalized total chemical shrinkage is approximately equal to the degree of cement hydration. By studying the correlations between the chemical shrinkage and the non-evaporable water content of cement during hydration, a multi-linear model is first proposed to estimate the normalization factors for different types of cement under different curing conditions. Based on the hydration kinetics data obtained from chemical shrinkage test results, a new approach of modeling the effect of curing temperature and pressure on cement hydration kinetics is proposed. It is found that when a hydration kinetics curve is represented by an unknown function, the effect of curing condition on the curve can be modeled by incorporating a simple scale factor in this function. The relationship between this scale factor and curing condition is described by chemical kinetics laws. While the proposed new approach of modeling cement hydration kinetics has the advantage of being widely applicable to different types of cement, it only explains one influence factor of cement hydration (i.e. the curing condition). In order to take into account other influence factors and to further understand the fundamental mechanisms of cement hydration, a more complex particle-based numerical hydration model is developed by combining the two well-known cement hydration mechanisms, namely the nucleation and growth controlled mechanism and the diffusion controlled mechanism. The model is applied to experimental data of both C3S hydration in dilute suspensions and Class H cement paste hydration. Excellent agreement is observed between experimental and modeled results. Three rate-controlling parameters with clear physical meanings can be identified from the proposed model. Fitted model parameters are found to be in reasonable agreement with experimental observation. The dependencies of these parameters on particle size, cement composition, w/c ratio, and curing condition are also investigated. Finally, the importance of cement hydration kinetics is illustrated by showing their close correlations with the physical and mechanical properties. The various influence factors, including the curing temperature and pressure, of physical and mechanical property test results (particularly density and tensile strength) are evaluated. Potential damage mechanisms of cement paste specimens during depressurization are studied by analyzing the deformation behavior of the entire system consisting of the cement paste and pressurizing water.
Samimi, Pooran; Alizadeh, Mehdi; Shirban, Farinaz; Davoodi, Amin; Khoroushi, Maryam
2016-01-01
Dual-cured composite resins are similar to self-cured composite resins in some of their clinical applications due to inadequate irradiation, lack of irradiation, or delayed irradiation. Therefore, incompatibility with self-etch adhesives (SEAs) should be taken into account with their use. On the other, the extent of dentin dehydration has a great role in the quality of adhesion of these resin materials to dentin. The aim of this study was to investigate the effect of dentin dehydration and composite resin polymerization mode on bond strength of two SEAs. A total of 120 dentinal specimens were prepared from extracted intact third molars. Half of the samples were dehydrated in ethanol with increasing concentrations. Then Clearfil SE Bond (CSEB) and Prompt L-Pop (PLP) adhesives were applied in the two groups. Cylindrical composite resin specimens were cured using three polymerization modes: (1) Immediate light-curing, (2) delayed light-curing after 20 min, and (3) self-curing. Bond strength was measured using universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with two-way ANOVA and Duncan post hoc tests. Statistical significance was defined at P < 0.05. There were no significant differences for CSEB subgroups with hydrated and dehydrated dentin samples between the three different curing modes (P > 0.05). PLP showed significant differences between subgroups with the lowest bond strength in hydrated dentin with delayed light-curing and self-cured mode of polymerization. Within the limitations of this study, a delay in composite resin light-curing or using chemically cured composite resin had a deleterious effect on dentin bond strength of single-step SEAs used in the study.
Samimi, Pooran; Alizadeh, Mehdi; Shirban, Farinaz; Davoodi, Amin; Khoroushi, Maryam
2016-01-01
Background: Dual-cured composite resins are similar to self-cured composite resins in some of their clinical applications due to inadequate irradiation, lack of irradiation, or delayed irradiation. Therefore, incompatibility with self-etch adhesives (SEAs) should be taken into account with their use. On the other, the extent of dentin dehydration has a great role in the quality of adhesion of these resin materials to dentin. The aim of this study was to investigate the effect of dentin dehydration and composite resin polymerization mode on bond strength of two SEAs. Materials and Methods: A total of 120 dentinal specimens were prepared from extracted intact third molars. Half of the samples were dehydrated in ethanol with increasing concentrations. Then Clearfil SE Bond (CSEB) and Prompt L-Pop (PLP) adhesives were applied in the two groups. Cylindrical composite resin specimens were cured using three polymerization modes: (1) Immediate light-curing, (2) delayed light-curing after 20 min, and (3) self-curing. Bond strength was measured using universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with two-way ANOVA and Duncan post hoc tests. Statistical significance was defined at P < 0.05. Results: There were no significant differences for CSEB subgroups with hydrated and dehydrated dentin samples between the three different curing modes (P > 0.05). PLP showed significant differences between subgroups with the lowest bond strength in hydrated dentin with delayed light-curing and self-cured mode of polymerization. Conclusion: Within the limitations of this study, a delay in composite resin light-curing or using chemically cured composite resin had a deleterious effect on dentin bond strength of single-step SEAs used in the study. PMID:27041894
Human recombinant epidermal growth factor in skin lesions: 77 cases in EPItelizando project.
Esquirol-Caussa, Jordi; Herrero-Vila, Elisabeth
2018-05-10
To analyze compounded recombinant human epidermal growth factor (rhEGF) effectiveness on skin lesions through a case series. Multicentric series of skin lesions treated with topical rhEGF. Site: Patients from 56 different health professionals, three different countries, and two recruitment years. Seventy-seven patients with skin lesions, mean age of 63.15 years (min = 18, max = 95); 53.2% of patients were men and 46.8% were women; 47 of the lesions were ulcers (venous, arterial, and diabetic foot), others were surgical and traumatic wounds, burns, and scars. Most common pathologies were type 2 diabetes mellitus and chronic venous insufficiency. Mean previous evolution time before inclusion was 29.59 months. Cures using compounded topical rhEGF most commonly used rhEGF concentration: 30 μg/g; most used excipient: gel; average time between cures: 36 h (24-48); and mean follow-up: 6.6 weeks (max = 20). Lesions appearance, margins and bed, lesional size evolution, treatment subjective effectiveness, tolerability and comfort through professional oppinion. Qualitative assessment: effectiveness 8.65, tolerability 9.53, and comfort 8.86 (max = 10). Perilesional skin showed improvement in 93.5% of the cases, lesions margins and wound bed appearance improved in 92.2% of the cases, respectively. Wound area decreased a mean average of 66.7%. About 43.3% of included venous ulcers had a greater than 40% cure rate in 4 weeks. Heterogeneity of the included pathologies, limited time follow-up in some cases. Topical rhEGF in individualized formulation (compounding) seems to exhibit effectiveness, comfort, and tolerability. Further larger-size studies with experimental design will allow to establish more precise concentrations, indications, and clinical guidelines.
Oberholzer, T G; Makofane, M E; du Preez, I C; George, R
2012-06-01
Pulpal temperature changes induced by modern high powered light emitting diodes (LEDs) are of concern when used to cure composite resins. This study showed an increase in pulp chamber temperature with an increase in power density for all light cure units (LCU) when used to bulk cure composite resin. Amongst the three LEDs tested, the Elipar Freelight-2 recorded the highest temperature changes. Bulk curing recorded a significantly larger rise in pulp chamber temperature change than incrementally cured resin for all light types except for the Smartligh PS. Both the high powered LED and the conventional curing units can generate heat. Though this temperature rise may not be sufficient to cause irreversible pulpal damage, it would be safer to incrementally cure resins.
Fiber-optic epoxy composite cure sensor. II. Performance characteristics
NASA Astrophysics Data System (ADS)
Lam, Kai-Yuen; Afromowitz, Martin A.
1995-09-01
The performance of a fiber-optic epoxy composite cure sensor, as previously proposed, depends on the optical properties and the reaction kinetics of the epoxy. The reaction kinetics of a typical epoxy system are presented. It is a third-order autocatalytic reaction with a peak observed in each isothermal reaction-rate curve. A model is derived to describe the performance characteristics of the epoxy cure sensor. If a composite coupon is cured at an isothermal temperature, the sensor signal can be used to predict the time when the gel point occurs and to monitor the cure process. The sensor is also shown to perform well in nonstoichiometric epoxy matrices. In addition the sensor can detect the end of the cure without calibration.
Animal Models for HIV Cure Research.
Policicchio, Benjamin B; Pandrea, Ivona; Apetrei, Cristian
2016-01-01
The HIV-1/AIDS pandemic continues to spread unabated worldwide, and no vaccine exists within our grasp. Effective antiretroviral therapy (ART) has been developed, but ART cannot clear the virus from the infected patient. A cure for HIV-1 is badly needed to stop both the spread of the virus in human populations and disease progression in infected individuals. A safe and effective cure strategy for human immunodeficiency virus (HIV) infection will require multiple tools, and appropriate animal models are tools that are central to cure research. An ideal animal model should recapitulate the essential aspects of HIV pathogenesis and associated immune responses, while permitting invasive studies, thus allowing a thorough evaluation of strategies aimed at reducing the size of the reservoir (functional cure) or eliminating the reservoir altogether (sterilizing cure). Since there is no perfect animal model for cure research, multiple models have been tailored and tested to address specific quintessential questions of virus persistence and eradication. The development of new non-human primate and mouse models, along with a certain interest in the feline model, has the potential to fuel cure research. In this review, we highlight the major animal models currently utilized for cure research and the contributions of each model to this goal.
Animal Models for HIV Cure Research
Policicchio, Benjamin B.; Pandrea, Ivona; Apetrei, Cristian
2016-01-01
The HIV-1/AIDS pandemic continues to spread unabated worldwide, and no vaccine exists within our grasp. Effective antiretroviral therapy (ART) has been developed, but ART cannot clear the virus from the infected patient. A cure for HIV-1 is badly needed to stop both the spread of the virus in human populations and disease progression in infected individuals. A safe and effective cure strategy for human immunodeficiency virus (HIV) infection will require multiple tools, and appropriate animal models are tools that are central to cure research. An ideal animal model should recapitulate the essential aspects of HIV pathogenesis and associated immune responses, while permitting invasive studies, thus allowing a thorough evaluation of strategies aimed at reducing the size of the reservoir (functional cure) or eliminating the reservoir altogether (sterilizing cure). Since there is no perfect animal model for cure research, multiple models have been tailored and tested to address specific quintessential questions of virus persistence and eradication. The development of new non-human primate and mouse models, along with a certain interest in the feline model, has the potential to fuel cure research. In this review, we highlight the major animal models currently utilized for cure research and the contributions of each model to this goal. PMID:26858716
Pahlevan, Ayob; Tabatabaei, Masumeh Hasani; Arami, Sakineh; Valizadeh, Sara
2016-01-01
Objectives: Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights. Materials and Methods: DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were placed in Teflon molds and cured from the top. The thermocouple under samples recorded the temperature rise. After initial radiation and specimens reaching the ambient temperature, reirradiation was done and temperature was recorded again. Both temperature rise and DC data submitted to one-way ANOVA and Tukey-HSD tests (5% significance). Results: The obtained results revealed that DC was not significantly different between the understudy composite resins or curing units. Low shrinkage composite resin showed a significantly higher temperature rise than hybrid composite resin. Argon laser caused the lowest temperature rise among the curing units. Conclusion: Energy density of light curing units was correlated with the DC. Type of composite resin and light curing unit had a significant effect on temperature rise due to polymerization and curing unit, respectively. PMID:27843507
Pahlevan, Ayob; Tabatabaei, Masumeh Hasani; Arami, Sakineh; Valizadeh, Sara
2016-01-01
Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights. DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were placed in Teflon molds and cured from the top. The thermocouple under samples recorded the temperature rise. After initial radiation and specimens reaching the ambient temperature, reirradiation was done and temperature was recorded again. Both temperature rise and DC data submitted to one-way ANOVA and Tukey-HSD tests (5% significance). The obtained results revealed that DC was not significantly different between the understudy composite resins or curing units. Low shrinkage composite resin showed a significantly higher temperature rise than hybrid composite resin. Argon laser caused the lowest temperature rise among the curing units. Energy density of light curing units was correlated with the DC. Type of composite resin and light curing unit had a significant effect on temperature rise due to polymerization and curing unit, respectively.
The Effect of Curing Temperature on the Properties of Cement Pastes Modified with TiO2 Nanoparticles
Pimenta Teixeira, Karine; Perdigão Rocha, Isadora; De Sá Carneiro, Leticia; Flores, Jessica; Dauer, Edward A.; Ghahremaninezhad, Ali
2016-01-01
This paper investigates the effect of curing temperature on the hydration, microstructure, compressive strength, and transport of cement pastes modified with TiO2 nanoparticles. These characteristics of cement pastes were studied using non-evaporable water content measurement, X-ray diffraction (XRD), compressive strength test, electrical resistivity and porosity measurements, and scanning electron microscopy (SEM). It was shown that temperature enhanced the early hydration. The cement pastes cured at elevated temperatures generally showed an increase in compressive strength at an early age compared to the cement paste cured at room temperature, but the strength gain decreased at later ages. The electrical resistivity of the cement pastes cured at elevated temperatures was found to decrease more noticeably at late ages compared to that of the room temperature cured cement paste. SEM examination indicated that hydration product was more uniformly distributed in the microstructure of the cement paste cured at room temperature compared to the cement pastes cured at elevated temperatures. It was observed that high temperature curing decreased the compressive strength and electrical resistivity of the cement pastes at late ages in a more pronounced manner when higher levels of TiO2 nanoparticles were added. PMID:28774073
NASA Astrophysics Data System (ADS)
Chehura, E.; Skordos, A. A.; Ye, C.-C.; James, S. W.; Partridge, I. K.; Tatam, R. P.
2005-04-01
Fibre Bragg gratings (FBGs) fabricated in linearly birefringent fibres were embedded in glass fibre/epoxy composites and in the corresponding unreinforced resin to monitor the effective transverse strain development during the cure process. The optical fibres containing the FBG sensors were aligned either normal or parallel to the reinforcement fibres in unidirectional glass fibre/epoxy prepregs. The chemical cure kinetics of the epoxy resin system used were studied using differential scanning calorimetry, in order to investigate the correlation between the strain monitoring results and the evolution of the curing reaction. A non-parametric cure kinetics model was developed and validated for this purpose. The effective transverse strain measured by the FBGs demonstrated high sensitivity to the degree of cure as a result of the densification of the resin caused by the curing reaction. The effective compressive transverse strain developed during the reaction, and thus the corresponding sensitivity to chemical changes, was higher in the case of the sensing fibre aligned normal to the reinforcement fibres than in the case of the sensor fibre parallel to the reinforcement fibres. Small but measurable sensitivity to cure induced changes was observed in the case of the unreinforced resin.
Chu, Carissa; Ananworanich, Jintanat; Excler, Jean-Louis; Tucker, Joseph D.
2015-01-01
Abstract Clinical and basic science advances have raised considerable hope for achieving an HIV cure by accelerating research. This research is dominated primarily by issues about the nature and design of current and future clinical trials. Stakeholder engagement for HIV cure remains in its early stages. Our analysis examines timing and mechanisms of historical stakeholder engagement in other HIV research areas for HIV-uninfected individuals [vaccine development and pre-exposure prophylaxis (PrEP)], and HIV-infected individuals (treatment as prevention, prevention of mother-to-child transmission, and treatment of acute HIV infection) and articulate a plan for HIV cure stakeholder engagement. The experience from HIV vaccine development shows that early engagement of stakeholders helped manage expectations, mitigating the failure of several vaccine trials, while paving the way for subsequent trials. The relatively late engagement of HIV stakeholders in PrEP research may partly explain some of the implementation challenges. The treatment-related stakeholder engagement was strong and community-led from the onset and helped translation from research to implementation. We outline five steps to initiate and sustain stakeholder engagement in HIV cure research and conclude that stakeholder engagement represents a key investment in which stakeholders mutually agree to share knowledge, benefits, and risk of failure. Effective stakeholder engagement prevents misconceptions. As HIV cure research advances from early trials involving subjects with generally favorable prognosis to studies involving greater risk and uncertainty, success may depend on early and deliberate engagement of stakeholders. PMID:26061668
Lo, Ying-Ru; Chu, Carissa; Ananworanich, Jintanat; Excler, Jean-Louis; Tucker, Joseph D
2015-07-01
Clinical and basic science advances have raised considerable hope for achieving an HIV cure by accelerating research. This research is dominated primarily by issues about the nature and design of current and future clinical trials. Stakeholder engagement for HIV cure remains in its early stages. Our analysis examines timing and mechanisms of historical stakeholder engagement in other HIV research areas for HIV-uninfected individuals [vaccine development and pre-exposure prophylaxis (PrEP)], and HIV-infected individuals (treatment as prevention, prevention of mother-to-child transmission, and treatment of acute HIV infection) and articulate a plan for HIV cure stakeholder engagement. The experience from HIV vaccine development shows that early engagement of stakeholders helped manage expectations, mitigating the failure of several vaccine trials, while paving the way for subsequent trials. The relatively late engagement of HIV stakeholders in PrEP research may partly explain some of the implementation challenges. The treatment-related stakeholder engagement was strong and community-led from the onset and helped translation from research to implementation. We outline five steps to initiate and sustain stakeholder engagement in HIV cure research and conclude that stakeholder engagement represents a key investment in which stakeholders mutually agree to share knowledge, benefits, and risk of failure. Effective stakeholder engagement prevents misconceptions. As HIV cure research advances from early trials involving subjects with generally favorable prognosis to studies involving greater risk and uncertainty, success may depend on early and deliberate engagement of stakeholders.
Early hardness of self-adhesive resin cements cured under indirect resin composite restorations.
Giráldez, Isabel; Ceballos, Laura; Garrido, Miguel A; Rodríguez, Jesús
2011-04-01
To determine the influence of curing mode on the surface hardness of seven resin cements used to lute indirect composite restorations. Seven commercial dual-curing resin cements were tested: two were total-etch (RelyX ARC [3M ESPE, St. Paul, MN, USA] and Variolink II [Ivoclar Vivadent, Schaan, Liechtenstein]); one was self-etch (Multilink Automix [Ivoclar Vivadent]), and four were self-adhesive (RelyX Unicem [3M ESPE], Maxcem Elite [Kerr Corp., Orange, CA, USA], SmartCem2 [Dentsply, Detrey, GmbH, Konstanz, Germany], and G-Cem [GC CORPORATION, Itabashi-Ku, Tokyo, Japan]). Three specimens (0.5 × 6.5mm) of each material were prepared for each of three experimental groups: Group 1 (cements allowed to self cure); Group 2 (cements light-cured for 40 seconds); and Group 3 (cements light-cured for 80 seconds). All specimens were cured through a 4-mm-thick composite cylinder (Filtek Z250-A3). Surface microhardness numbers were determined at 20 min after preparation. Results were analyzed by two-way analysis of variance and Student-Newman-Keuls tests (p<0.05). Superficial hardness was significantly influenced by the resin cement tested (p<0.0001), the curing mode (p<0.0001), and their interaction (p<0.0001). RelyX ARC exhibited the highest mean microhardness values regardless of the curing mode. Light-curing significantly increased the microhardness of all resin cements studied, and these values increased even further with a doubling of irradiation time. Self-adhesive cements exhibited different behavior according to the curing mode. RelyX Unicem was highly sensitive to light irradiation, showing the lowest mean values in the self-curing mode. After light irradiation for 40 or 80 seconds, Maxcem Elite exhibited the lowest mean hardness values of all the resin cements tested. The microhardness of resin cements is highly dependent on the brand. Dual-curing resin cements should always be light irradiated for longer periods than that recommended by manufacturers. Dual-curing resin cements should always be light-cured for longer irradiation times, as light irradiation for 80 seconds yields the highest microhardness values in comparison with self-curing or light irradiation for 40 seconds. However, some self-adhesive resin cements exhibit low microhardness values when used to cement 4-mm-thick indirect composite restorations regardless of the curing mode applied. © 2011, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2011, WILEY PERIODICALS, INC.
Thermal Curing Process Monitoring of the Composite Material Using the FBG sensor
NASA Astrophysics Data System (ADS)
Zhang, Youhong; Chang, Xinlong; Zhang, Xiaojun; He, Xiangyong
2018-03-01
The raw composite material will suffer complex chemical and morphological changes during the thermal curing process, and it is difficult to monitor the curing process and curing effect. In this paper, the FBG sensor was embedded in the raw composite material to monitor the whole curing process. The experiment results showed that the FBG sensor can monitor the resin transformation and residual deformation of the composite material, and the FBG sensor can be applied to monitor the thermal curing process of the composite structure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janke, C.J.
Electron beam (EB) curing is a technology that promises, in certain applications, to deliver lower cost and higher performance polymer matrix composite (PMC) structures compared to conventional thermal curing processes. PMCs enhance performance by making products lighter, stronger, more durable, and less energy demanding. They are essential in weight- and performance-dominated applications. Affordable PMCs can enhance US economic prosperity and national security. US industry expects rapid implementation of electron beam cured composites in aircraft and aerospace applications as satisfactory properties are demonstrated, and implementation in lower performance applications will likely follow thereafter. In fact, at this time and partly becausemore » of discoveries made in this project, field demonstrations are underway that may result in the first fielded applications of electron beam cured composites. Serious obstacles preventing the widespread use of electron beam cured PMCs in many applications are their relatively poor interfacial properties and resin toughness. The composite shear strength and resin toughness of electron beam cured carbon fiber reinforced epoxy composites were about 25% and 50% lower, respectively, than those of thermally cured composites of similar formulations. The essential purpose of this project was to improve the mechanical properties of electron beam cured, carbon fiber reinforced epoxy composites, with a specific focus on composite shear properties for high performance aerospace applications. Many partners, sponsors, and subcontractors participated in this project. There were four government sponsors from three federal agencies, with the US Department of Energy (DOE) being the principal sponsor. The project was executed by Oak Ridge National Laboratory (ORNL), NASA and Department of Defense (DOD) participants, eleven private CRADA partners, and two subcontractors. A list of key project contacts is provided in Appendix A. In order to properly manage the large project team and properly address the various technical tasks, the CRADA team was organized into integrated project teams (IPT's) with each team focused on specific research areas. Early in the project, the end user partners developed ''exit criteria'', recorded in Appendix B, against which the project's success was to be judged. The project team made several important discoveries. A number of fiber coatings or treatments were developed that improved fiber-matrix adhesion by 40% or more, according to microdebond testing. The effects of dose-time and temperature-time profiles during the cure were investigated, and it was determined that fiber-matrix adhesion is relatively insensitive to the irradiation procedure, but can be elevated appreciably by thermal postcuring. Electron beam curable resin properties were improved substantially, with 80% increase in electron beam 798 resin toughness, and {approx}25% and 50% improvement, respectively, in ultimate tensile strength and ultimate tensile strain vs. earlier generation electron beam curable resins. Additionally, a new resin electron beam 800E was developed with generally good properties, and a very notable 120% improvement in transverse composite tensile strength vs. earlier generation electron beam cured carbon fiber reinforced epoxies. Chemical kinetics studies showed that reaction pathways can be affected by the irradiation parameters, although no consequential effects on material properties have been noted to date. Preliminary thermal kinetics models were developed to predict degree of cure vs. irradiation and thermal parameters. These models are continually being refined and validated. Despite the aforementioned impressive accomplishments, the project team did not fully realize the project objectives. The best methods for improving adhesion were combined with the improved electron beam 3K resin to make prepreg and uni-directional test laminates from which composite properties could be determined. Nevertheless, only minor improvements in the composite shear strength, and moderate improvements in the transverse tensile strength, were achieved. The project team was not satisfied with the laminate quality achieved, and low quality (specifically, high void fraction) laminates will compromise the composite properties. There were several problems with the prepregging and fabrication, many of them related to the use of new fiber treatments.« less
Self-curing concrete with different self-curing agents
NASA Astrophysics Data System (ADS)
Gopala krishna sastry, K. V. S.; manoj kumar, Putturu
2018-03-01
Concrete is recognised as a versatile construction material globally. Properties of concrete depend upon, to a greater extent, the hydration of cement and microstructure of hydrated cement. Congenial atmosphere would aid the hydration of cement and hence curing of concrete becomes essential, till a major portion of the hydration process is completed. But in areas of water inadequacy and concreting works at considerable heights, curing is problematic. Self-Curing or Internal Curing technique overcomes these problems. It supplies redundant moisture, for more than sufficient hydration of cement and diminish self-desiccation. Self-Curing agents substantially help in the conservation of water in concrete, by bringing down the evaporation during the hydration of Concrete. The present study focuses on the impact of self-curing agents such as Poly Ethylene Glycol (PEG), Poly Vinyl Alcohol (PVA) and Super Absorbent Polymer (SAP) on the concrete mix of M25 grade (reference mix). The effect of these agents on strength properties of Concrete such as compressive strength, split tensile strength and flexural strength was observed on a comparative basis which revealed that PEG 4000 was the most effective among all the agents.
del Olmo, Ana; Calzada, Javier; Nuñez, Manuel
2013-11-01
Lipolysis, lipid peroxidation, and colorimetric characteristics of Serrano hams from Duroc and Large White pigs along a 15-mo curing period were investigated. Physicochemical parameters of both types of hams evolved similarly during curing. Twelve of 13 free fatty acids (FFAs) increased during curing, eicosatrienoic acid being the only exception. Linoleic, stearic, and arachidonic acids and the minor heptadecanoic acid reached lower concentrations, and the rest of minor FFAs higher concentrations, in Duroc hams than in Large White hams. The index measuring the early stage of lipid peroxidation declined from month 5 onwards, indicating that the phenomenon had been completed by month 5, while the index of the secondary stage of lipid peroxidation increased with curing time. Higher values were found for the 1st index in Duroc hams. Curing affected color parameters. Lightness decreased and redness increased in both types of hams, while yellowness decreased only in Duroc hams. Lower redness values were found for Duroc hams. Major differences in color parameters were found between muscles. Principal components analysis of FFAs yielded 2 main principal components. The 1st factor, correlated with all FFAs excepting eicosatrienoic acid, allowed discrimination between curing times. The 2nd factor, correlated with eicosatrienoic acid, permitted discrimination between breeds. © 2013 Institute of Food Technologists®
Effect of cementitious permanent formwork on moisture field of internal-cured concrete under drying
NASA Astrophysics Data System (ADS)
Wang, Jiahe; Zhang, Jun; Ding, Xiaoping; Zhang, Jiajia
2018-02-01
Drying shrinkage of concrete may still be the main source of cracking in concrete structures, even though the autogenous shrinkage of concrete can be effectively reduced by using internal curing. In the present paper, the effect of internal curing with pre-soaked lightweight aggregate and engineered cementitious composite permanent formwork (ECC-PF) on a moisture distribution in three kinds of concrete in a drying environment are investigated from both aspects of experiments and theoretical modeling. The test results show that the combination use of ECC-PF and internal curing can well maintain the humidity at a relatively high level not only at a place far from drying surface, but also at a place close to the drying surfaces. The developed model can well catch the characteristics of the moisture distribution in concrete under drying and the impacts of internal curing and ECC-PF can well be reflected as well. The model can be used for the design of concrete structures with combination use of internal curing and permanent formwork.
Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne
2016-09-01
Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Changes in degree of conversion and microhardness of dental resin cements.
Yan, Yong Li; Kim, Young Kyung; Kim, Kyo-Han; Kwon, Tae-Yub
2010-01-01
There are few studies available on the post-light activation or post-mix polymerization of dental resin cements as a function of time. This in vitro study evaluated the successive changes in the degree of conversion (DC) and microhardness during polymerization of six commercial resin cements (light-cured [Choice 2, RelyX Veneer], chemical-cured [Multilink, C&B Cement] and dual-cured [Calibra, RelyX ARC]) within the first 24 hours and up to seven days. Resin specimens were prepared for Fourier transform infrared (FTIR) spectroscopy and microhardness testing to determine the DC and Vickers hardness (VH), respectively. The light-cured materials or mixed pastes of the dual-cured materials were irradiated with a light-curing unit (Elipar TriLight) through a precured composite overlay for 40 seconds. The FTIR spectra and microhardness readings were taken at specified times: 1, 2, 5, 10, 15, 30 and 60 minutes; 24 hours and after two days and seven days. According to the FTIR study, most of the curing reaction of Choice 2 and RelyX Veneer occurred within 10 and 30 minutes, respectively. Multilink, C&B Cement and Calibra exhibited gradual increases in the DC up to 24 hours, with no further statistically significant increase (p > 0.05). RelyX ARC attained a DC value within five minutes, similar to that at seven days (p > 0.05). Choice 2 and RelyXARC showed gradual increases in the VH, up to 15 minutes, with no further significant change over the remaining observation time (p > 0.05). For RelyX Veneer, Multilink, C&B Cement and Calibra, there were no significant increases in the VH value after 24 hours (p > 0.05). The light-cured materials produced significantly higher DC values than the chemical-cured materials (p < 0.05). The DC values of the two dual-cured resin cements were significantly different from each other (p < 0.001). The results suggest that the significant polymerization reaction was finished within 24 hours post-mix or post-light activation for all resin cements tested.
Thermal processing of EVA encapsulants and effects of formulation additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pern, F.J.; Glick, S.H.
1996-05-01
The authors investigated the in-situ processing temperatures and effects of various formulation additives on the formation of ultraviolet (UV) excitable chromophores, in the thermal lamination and curing of ethylene-vinyl acetate (EVA) encapsulants. A programmable, microprocessor-controlled, double-bag vacuum laminator was used to study two commercial as formulated EVA films, A9918P and 15295P, and solution-cast films of Elvaxrm (EVX) impregnated with various curing agents and antioxidants. The results show that the actual measured temperatures of EVA lagged significantly behind the programmed profiles for the heating elements and were affected by the total thermal mass loaded inside the laminator chamber. The antioxidant Naugardmore » P{trademark}, used in the two commercial EVA formulations, greatly enhances the formation of UV-excitable, short chromophores upon curing, whereas other tested antioxidants show little effect. A new curing agent chosen specifically for the EVA formulation modification produces little or no effect on chromophore formation, no bubbling problems in the glass/EVX/glass laminates, and a gel content of {approximately}80% when cured at programmed 155{degrees}C for 4 min. Also demonstrated is the greater discoloring effect with higher concentrations of curing-generated chromophores.« less
Thermal processing of EVA encapsulants and effects of formulation additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pern, F.J.; Glick, S.H.
1996-09-01
The authors investigated the in-situ processing temperatures and effects of various formulation additives on the formation of ultraviolet (UV) excitable chromophores in the thermal lamination and curing of ethylene-vinyl acetate (EVA) encapsulants. A programmable, microprocessor-controlled, double-bag vacuum laminator was used to study two commercial as-formulated EVA films. A9918P and 15295P, and solution-cast films of Elvax{trademark} (EVX) impregnated with various curing agents and antioxidants. The results show that the actual measured temperatures of EVA lagged significantly behind the programmed profiles for the heating elements and were affected by the total thermal mass loaded inside the laminator chamber. The antioxidant Naugard P{trademark},more » used in the two commercial EVA formulations, greatly enhances the formation of UV-excitable, short chromophores upon curing, whereas other tested antioxidants show little effect. A new curing agent chosen specifically for the EVA formulation modification produces little or no effect on chromophore formation, no bubbling problems in the glass/EVX/glass laminates, and a gel content of {approximately}80% when cured at programmed 155 C for 4 min. Also demonstrated is the greater discoloring effect with higher concentrations of curing-generated chromophores.« less
2.45 GHz Microwave Processing and Its Influence on Glass Fiber Reinforced Plastics.
Teufl, Daniel; Zaremba, Swen
2018-05-18
During the production of fiber-reinforced composite materials, liquid resin is introduced into the fiber material and cured, i.e., hardened. An elevated temperature is needed for this curing. Microwave curing of composites has been investigated for some time, but it has mostly been done using small domestic or laboratory equipment. However, no investigation has been carried out using an industrial-sized chamber-microwave for glass fiber-reinforced plastic (GFRP). Here, we show that microwave curing produces laminates of the same quality as oven-cured ones. The study shows that, if the process is done right, GFRP samples can be produced with an industrial scale microwave. Even if not fully cured, microwave samples show a glass transition temperature measured with DMA ( T g-DMA ) that is comparable to the T g-DMA according to the proposed cure cycle on the data sheet. Specific microwave-cured configurations show better inter-laminar shear strength than oven specimens. The results show that microwave-based heat introduction can be a beneficial curing method for GFRP laminates. A microwave-optimized process is faster and leads to better mechanical properties.
NASA Astrophysics Data System (ADS)
Li, Dongna; Li, Xudong; Dai, Jianfeng
2018-06-01
In this paper, two kinds of transient models, the viscoelastic model and the linear elastic model, are established to analyze the curing deformation of the thermosetting resin composites, and are calculated by COMSOL Multiphysics software. The two models consider the complicated coupling between physical and chemical changes during curing process of the composites and the time-variant characteristic of material performance parameters. Subsequently, the two proposed models are implemented respectively in a three-dimensional composite laminate structure, and a simple and convenient method of local coordinate system is used to calculate the development of residual stresses, curing shrinkage and curing deformation for the composite laminate. Researches show that the temperature, degree of curing (DOC) and residual stresses during curing process are consistent with the study in literature, so the curing shrinkage and curing deformation obtained on these basis have a certain referential value. Compared the differences between the two numerical results, it indicates that the residual stress and deformation calculated by the viscoelastic model are more close to the reference value than the linear elastic model.
2.45 GHz Microwave Processing and Its Influence on Glass Fiber Reinforced Plastics
Zaremba, Swen
2018-01-01
During the production of fiber-reinforced composite materials, liquid resin is introduced into the fiber material and cured, i.e., hardened. An elevated temperature is needed for this curing. Microwave curing of composites has been investigated for some time, but it has mostly been done using small domestic or laboratory equipment. However, no investigation has been carried out using an industrial-sized chamber-microwave for glass fiber-reinforced plastic (GFRP). Here, we show that microwave curing produces laminates of the same quality as oven-cured ones. The study shows that, if the process is done right, GFRP samples can be produced with an industrial scale microwave. Even if not fully cured, microwave samples show a glass transition temperature measured with DMA (Tg-DMA) that is comparable to the Tg-DMA according to the proposed cure cycle on the data sheet. Specific microwave-cured configurations show better inter-laminar shear strength than oven specimens. The results show that microwave-based heat introduction can be a beneficial curing method for GFRP laminates. A microwave-optimized process is faster and leads to better mechanical properties. PMID:29783684
NASA Technical Reports Server (NTRS)
Hudson, Tyler B.; Hou, Tan-Hung; Grimsley, Brian W.; Yaun, Fuh-Gwo
2016-01-01
A guided wave-based in-process cure monitoring technique for carbon fiber reinforced polymer (CFRP) composites was investigated at NASA Langley Research Center. A key cure transition point (vitrification) was identified and the degree of cure was monitored using metrics such as amplitude and time of arrival (TOA) of guided waves. Using an automated system preliminarily developed in this work, high-temperature piezoelectric transducers were utilized to interrogate a twenty-four ply unidirectional composite panel fabricated from Hexcel (Registered Trademark) IM7/8552 prepreg during cure. It was shown that the amplitude of the guided wave increased sharply around vitrification and the TOA curve possessed an inverse relationship with degree of cure. The work is a first step in demonstrating the feasibility of transitioning the technique to perform in-process cure monitoring in an autoclave, defect detection during cure, and ultimately a closed-loop process control to maximize composite part quality and consistency.
Concordance measure and discriminatory accuracy in transformation cure models.
Zhang, Yilong; Shao, Yongzhao
2018-01-01
Many populations of early-stage cancer patients have non-negligible latent cure fractions that can be modeled using transformation cure models. However, there is a lack of statistical metrics to evaluate prognostic utility of biomarkers in this context due to the challenges associated with unknown cure status and heavy censorship. In this article, we develop general concordance measures as evaluation metrics for the discriminatory accuracy of transformation cure models including the so-called promotion time cure models and mixture cure models. We introduce explicit formulas for the consistent estimates of the concordance measures, and show that their asymptotically normal distributions do not depend on the unknown censoring distribution. The estimates work for both parametric and semiparametric transformation models as well as transformation cure models. Numerical feasibility of the estimates and their robustness to the censoring distributions are illustrated via simulation studies and demonstrated using a melanoma data set. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Factors affecting marginal integrity of class II bulk-fill composite resin restorations
Savadi Oskoee, Siavash; Bahari, Mahmoud; Jafari Navimipour, Elmira; Ajami, Amir Ahmad; Ghiasvand, Negar; Savadi Oskoee, Ayda
2017-01-01
Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (P<0.05), post hoc Bonferroni test was used for further analyses. Results. The light-curing unit type had no effect on gap formation. However, the results were significant in relation to the composite resin type and margin location (P<0.001). The cumulative effects of light-curing unit*gingival margin and light-curing unit*composite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins. PMID:28748051
INTEGRATION OF COST MODELS AND PROCESS SIMULATION TOOLS FOR OPTIMUM COMPOSITE MANUFACTURING PROCESS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pack, Seongchan; Wilson, Daniel; Aitharaju, Venkat
Manufacturing cost of resin transfer molded composite parts is significantly influenced by the cycle time, which is strongly related to the time for both filling and curing of the resin in the mold. The time for filling can be optimized by various injection strategies, and by suitably reducing the length of the resin flow distance during the injection. The curing time can be reduced by the usage of faster curing resins, but it requires a high pressure injection equipment, which is capital intensive. Predictive manufacturing simulation tools that are being developed recently for composite materials are able to provide variousmore » scenarios of processing conditions virtually well in advance of manufacturing the parts. In the present study, we integrate the cost models with process simulation tools to study the influence of various parameters such as injection strategies, injection pressure, compression control to minimize high pressure injection, resin curing rate, and demold time on the manufacturing cost as affected by the annual part volume. A representative automotive component was selected for the study and the results are presented in this paper« less
40 CFR 63.4165 - How do I determine the emission capture system efficiency?
Code of Federal Regulations, 2010 CFR
2010-07-01
... system; coating solvent flash-off and coating, curing, and drying occurs within the capture system and... when being moved between a spray booth and a curing oven. (b) If the capture system does not meet both... surface preparation activities and drying or curing time. (c) Liquid-to-uncaptured-gas protocol using a...
Morphological and mechanical properties of styrene butadiene rubber/nano copper nanocomposites
NASA Astrophysics Data System (ADS)
Harandi, Maryam Hadizadeh; Alimoradi, Fakhrodin; Rowshan, Gholamhussein; Faghihi, Morteza; Keivani, Maryam; Abadyan, Mohamadreza
In this research, rubber based nanocomposites with presence of nanoparticle has been studied. Styrene butadiene rubber (SBR)/nanocopper (NC) composites were prepared using two-roll mill method. Transmission electron microscope (TEM) and scanning electron microscope (SEM) images showed proper dispersion of NC in the SBR matrix without substantial agglomeration of nanoparticles. To evaluate the curing properties of nanocomposite samples, swelling and cure rheometric tests were conducted. Moreover, the rheological studies were carried out over a range of shear rates. The effect of NC particles was examined on the thermal behavior of the SBR using thermal gravimetric analysis (TGA). Furthermore, tensile tests were employed to investigate the capability of nanoparticles to enhance mechanical behavior of the compounds. The results showed enhancement in tensile properties with incorporation of NC to SBR matrix. Moreover, addition of NC increased shear viscosity and curing time of SBR composites.
NASA Astrophysics Data System (ADS)
Miller, Albert E.
Early age shrinkage of cementitious systems can result in an increased potential for cracking which can lead to a reduction in service life. Early age shrinkage cracking can be particularly problematic for high strength concretes, which are often specified due to their high strength and low permeability. However, these high strength concretes frequently exhibit a reduction in the internal relative humidity (RH) due to the hydration reaction (chemical shrinkage) and self-desiccation which results in a bulk shrinkage, termed autogenous shrinkage, which is substantial at early ages. Due to the low permeability of these concretes, standard external curing is not always efficient in addressing this reduction in internal RH since the penetration of water can be limited. Internal curing has been developed to reduce autogenous shrinkage. Internally cured mixtures use internal reservoirs filled with fluid (generally water) that release this fluid at appropriate times to counteract the effects of self-desiccation thereby maintaining a high internal RH. Internally cured concrete is frequently produced in North America using pre-wetted lightweight aggregate. One important aspect associated with preparing quality internally cured concrete is being able to determine the absorbed moisture and surface moisture associated with the lightweight aggregate which enables aggregate moisture corrections to be made for the concrete mixture. This thesis represents work performed to develop a test method using a centrifuge to determine the moisture state of pre-wetted fine lightweight aggregate. The results of the test method are then used in a series of worksheets that were developed to assist field technicians when performing the tests and applying the results to a mixture design. Additionally, research was performed on superabsorbent polymers to assess their ability to be used as an internal curing reservoir.
Cure effects on microcracking in IM7 fiber/Matrimid 5292{reg_sign} BMI composites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilenski, M.S.; Shin, E.; Morgan, R.J.
1995-12-31
Initial results from a study of the microcracking behavior of the Matrimid 5292{reg_sign} BMI/IM7 carbon fiber system are presented. Studies were performed to determine the composite`s Stress Free Temperature (SFT) which is seen to control the presence and extent of microcracking. The SFT was determined using asymmetric laminates [0{sub 2}/90{sub 2}]. Varied post-cure cycles were utilized and it was found that until complete cure is obtained, the SFT is a function of the highest temperature experienced by the laminate, with little effect of previous thermal history. The reactions necessary to fully cure this system are not active at temperatures belowmore » 250 C, ruling out the possibility of obtaining a fully cured composite with a low SFT through extended post-cures at lower temperatures.« less
NASA Astrophysics Data System (ADS)
Golestanian, Hossein
This research focuses on modeling Resin Transfer Molding process for manufacture of composite parts with woven fiber mats. Models are developed to determine cure dependent stiffness matrices for composites manufactured with two types of woven fiber mats. Five-harness carbon and eight-harness fiberglass mats with EPON 826 resin composites are considered. The models presented here take into account important material/process parameters with emphasis on; (1) The effects of cure-dependent resin mechanical properties, (2) Fiber undulation due to the weave of the fiber fill and warp bundles, and (3) Resin interaction with the fiber bundles at a microscopic scale. Cure-dependent mechanical properties were then used in numerical models to determine residual stresses and deformation in the composite parts. The complete cure cycle was modeled in these analyses. Also the cool down stage after the composite cure was analyzed. The effect of 5% resin shrinkage on residual stresses and deformations was also investigated. In the second part of the study, Finite Element models were developed to simulate mold filling in RTM processes. Resin flow in the fiber mats was modeled as flow through porous media. Physical models were also developed to investigate resin flow behavior into molds of rectangular and irregular shapes. Silicone fluids of 50 and 100 centistoke viscosities as well as EPON 826 epoxy resin were used in the mold filling experiments. The reinforcements consisted of several layers of woven fiberglass and carbon fiber mats. The effects of injection pressure, fluid viscosity, type of reinforcement, and mold geometry on mold filling times were investigated. Fiber mat permeabilities were determined experimentally for both types of reinforcements. Comparison of experimental and numerical resin front positions indicated the importance of edge effects in resin flow behavior in small cavities. The resin front positions agreed well for the rectangular mold geometry.
Defining the Chance of Statistical Cure Among Patients with Extrahepatic Biliary Tract Cancer.
Spolverato, Gaya; Bagante, Fabio; Ethun, Cecilia G; Poultsides, George; Tran, Thuy; Idrees, Kamran; Isom, Chelsea A; Fields, Ryan C; Krasnick, Bradley; Winslow, Emily; Cho, Clifford; Martin, Robert C G; Scoggins, Charles R; Shen, Perry; Mogal, Harveshp D; Schmidt, Carl; Beal, Eliza; Hatzaras, Ioannis; Shenoy, Rivfka; Maithel, Shishir K; Pawlik, Timothy M
2017-01-01
While surgery offers the best curative-intent treatment, many patients with biliary tract malignancies have poor long-term outcomes. We sought to apply a non-mixture cure model to calculate the cure fraction and the time to cure after surgery of patients with peri-hilar cholangiocarcinoma (PHCC) or gallbladder cancer (GBC). Using the Extrahepatic Biliary Malignancy Consortium, 576 patients who underwent curative-intent surgery for gallbladder carcinoma or peri-hilar cholangiocarcinoma between 1998 and 2014 at 10 major hepatobiliary institutions were identified and included in the analysis. A non-mixture cure model was adopted to compare mortality after surgery to the mortality expected for the general population matched by sex and age. The median and 5-year overall survival (OS) were 1.9 years (IQR, 0.9-4.9) and 23.9 % (95 % CI, 19.6-28.6). Among all patients with PHCC or GBC, the probability of being cured after surgery was 14.5 % (95 % CI, 8.7-23.2); the time to cure was 9.7 years and the median survival of uncured patients was 1.8 years. Determinants of cure probabilities included lymph node metastasis and CA 19.9 level (p ≤ 0.05). The cure fraction for patients with a CA 19.9 < 50 U/ml and no lymph nodes metastases were 39.0 % versus only 5.1 % among patients with a CA 19.9 ≥ 50 who also had lymph node metastasis. Examining an "all comer" cohort, <15 % of patients with PHCC or GBC could be considered cured after surgery. Factors such CA 19.9 level and lymph node metastasis independently predicted long-term outcome. Estimating the odds of statistical cure following surgery for biliary tract cancer can assist in decision-making as well as inform discussions around survivorship.
Defining the Chance of Statistical Cure Among Patients with Extrahepatic Biliary Tract Cancer
Spolverato, Gaya; Bagante, Fabio; Ethun, Cecilia G.; Poultsides, George; Tran, Thuy; Idrees, Kamran; Isom, Chelsea A.; Fields, Ryan C.; Krasnick, Bradley; Winslow, Emily; Cho, Clifford; Martin, Robert C. G.; Scoggins, Charles R.; Shen, Perry; Mogal, Harveshp D.; Schmidt, Carl; Beal, Eliza; Hatzaras, Ioannis; Shenoy, Rivfka; Maithel, Shishir K.; Pawlik, Timothy M.
2017-01-01
Background While surgery offers the best curative-intent treatment, many patients with biliary tract malignancies have poor long-term outcomes. We sought to apply a non-mixture cure model to calculate the cure fraction and the time to cure after surgery of patients with peri-hilar cholangiocarcinoma (PHCC) or gallbladder cancer (GBC). Methods Using the Extrahepatic Biliary Malignancy Consortium, 576 patients who underwent curative-intent surgery for gallbladder carcinoma or peri-hilar cholangiocarcinoma between 1998 and 2014 at 10 major hepatobiliary institutions were identified and included in the analysis. A non-mixture cure model was adopted to compare mortality after surgery to the mortality expected for the general population matched by sex and age. Results The median and 5-year overall survival (OS) were 1.9 years (IQR, 0.9–4.9) and 23.9 % (95 % CI, 19.6–28.6). Among all patients with PHCC or GBC, the probability of being cured after surgery was 14.5 % (95 % CI, 8.7–23.2); the time to cure was 9.7 years and the median survival of uncured patients was 1.8 years. Determinants of cure probabilities included lymph node metastasis and CA 19.9 level (p ≤ 0.05). The cure fraction for patients with a CA 19.9 < 50 U/ml and no lymph nodes metastases were 39.0 % versus only 5.1 % among patients with a CA 19.9 ≥ 50 who also had lymph node metastasis. Conclusions Examining an “all comer” cohort, <15 % of patients with PHCC or GBC could be considered cured after surgery. Factors such CA 19.9 level and lymph node metastasis independently predicted long-term outcome. Estimating the odds of statistical cure following surgery for biliary tract cancer can assist in decision-making as well as inform discussions around survivorship. PMID:27549595
Composite cements benefit from light-curing.
Lührs, Anne-Katrin; De Munck, Jan; Geurtsen, Werner; Van Meerbeek, Bart
2014-03-01
To investigate the effect of curing of composite cements and a new ceramic silanization pre-treatment on the micro-tensile bond strength (μTBS). Feldspathic ceramic blocks were luted onto dentin using either Optibond XTR/Nexus 3 (XTR/NX3; Kerr), the silane-incorporated 'universal' adhesive Scotchbond Universal/RelyX Ultimate (SBU/RXU; 3M ESPE), or ED Primer II/Panavia F2.0 (ED/PAF; Kuraray Noritake). Besides 'composite cement', experimental variables were 'curing mode' ('AA': complete auto-cure at 21°C; 'AA*': complete auto-cure at 37°C; 'LA': light-curing of adhesive and auto-cure of cement; 'LL': complete light-curing) and 'ceramic surface pre-treatment' ('HF/S/HB': hydrofluoric acid ('HF': IPS Ceramic Etching Gel, Ivoclar-Vivadent), silanization ('S': Monobond Plus, Ivoclar-Vivadent) and application of an adhesive resin ('HB': Heliobond, Ivoclar-Vivadent); 'HF/SBU': 'HF' and application of the 'universal' adhesive Scotchbond Universal ('SBU'; 3M ESPE, only for SBU/RXU)). After water storage (7 days at 37°C), ceramic-dentin sticks were subjected to μTBS testing. Regarding the 'composite cement', the significantly lowest μTBSs were measured for ED/PAF. Regarding 'curing mode', the significantly highest μTBS was recorded when at least the adhesive was light-cured ('LA' and 'LL'). Complete auto-cure ('AA') revealed the significantly lowest μTBS. The higher auto-curing temperature ('AA*') increased the μTBS only for ED/PAF. Regarding 'ceramic surface pre-treatment', only for 'LA' the μTBS was significantly higher for 'HF/S/HB' than for 'HF/SBU'. Complete auto-cure led to inferior μTBS than when either the adhesive (on dentin) or both adhesive and composite cement were light-cured. The use of a silane-incorporated adhesive did not decrease luting effectiveness when also the composite cement was light-cured. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Plackett-Burman experimental design to facilitate syntactic foam development
Smith, Zachary D.; Keller, Jennie R.; Bello, Mollie; ...
2015-09-14
The use of an eight-experiment Plackett–Burman method can assess six experimental variables and eight responses in a polysiloxane-glass microsphere syntactic foam. The approach aims to decrease the time required to develop a tunable polymer composite by identifying a reduced set of variables and responses suitable for future predictive modeling. The statistical design assesses the main effects of mixing process parameters, polymer matrix composition, microsphere density and volume loading, and the blending of two grades of microspheres, using a dummy factor in statistical calculations. Responses cover rheological, physical, thermal, and mechanical properties. The cure accelerator content of the polymer matrix andmore » the volume loading of the microspheres have the largest effects on foam properties. These factors are the most suitable for controlling the gel point of the curing foam, and the density of the cured foam. The mixing parameters introduce widespread variability and therefore should be fixed at effective levels during follow-up testing. Some responses may require greater contrast in microsphere-related factors. As a result, compared to other possible statistical approaches, the run economy of the Plackett–Burman method makes it a valuable tool for rapidly characterizing new foams.« less
Hyun, Hoon; Park, Min Ho; Lim, Wonbong; Kim, So Yeon; Jo, Danbi; Jung, Jin Seok; Jo, Gayoung; Um, Sewook; Lee, Deok-Won; Yang, Dae Hyeok
2018-05-11
Currently available chemotherapy is associated with serious side effects, and therefore novel drug delivery systems (DDSs) are required to specifically deliver anticancer drugs to targeted sites. In this study, we evaluated the feasibility of visible light-cured glycol chitosan (GC) hydrogels with controlled release of doxorubicin⋅hydrochloride (DOX⋅HCl) as local DDSs for effective cancer therapy in vivo. The storage modulus of the hydrogel precursor solutions was increased as a function of visible light irradiation time. In addition, the swelling ratio of the hydrogel irradiated for 10 s (GC 10 /DOX) was greater than in 60 s (GC 60 /DOX). In vitro release test showed that DOX was rapidly released in GC 10 /DOX compared with GC 60 /DOX due to the density of cross-linking. In vitro and in vivo tests including cell viability and measurement of tumor volume showed that the local treatment of GC 10 /DOX yielded substantially greater antitumor effect compared with that of GC 60 /DOX. Therefore, the visible light-cured GC hydrogel system may exhibit clinical potential as a local DDS of anticancer drugs with controlled release, by modulating cross-linking density.
de Moraes Porto, Isabel Cristina Celerino; Ramos de Brito, Andréia Cristina; Parolia, Abhishek
2013-01-01
Background: Among the advice on prevent cross-infection was included usage of mechanical barriers on tips of photoactivation units. However, questions about the use of protective barriers placed on the light-curing unit's tips and the possibility of interference with the ability of guaranteeing an effective polymerization of composite resins need to be clarified. Aims: The aim of this study was to evaluate the effect of cross infection control barriers used on the light-curing device tips on the cure depth of composite resin. Materials and Methods: Power density measurements from the light-cure unit were recorded with a radiometer on ten separate occasions with different types and placement modes of each barrier (low-density polyethylene and polyvinyl chloride (PVC) film – smooth and folds) and no-barrier (control). Cure depth of TPH™ Spectrum™ resin, A2-A4, was evaluated by the scraping test. Statistical Analysis: The data were analyzed using Student's t-test or ANOVA one-way with Tukey's test (α =0.05). Results: Same type of barrier and different shades (A2, A4) of composite exhibited significant difference in the cure depth among all groups (P < 0.05). Both low-density polyethylene and PVC film folded barriers produced a significant reduction in the light intensity (P < 0.05). Conclusions: Regarding the resin shade, there was a significant reduction in the cure depth of A4 composite resin (dark shade) but this reduction is not enough to cause any adverse effect on the material's clinical performance. Therefore, disposable barriers can be recommended for use over the end of the light guide. PMID:23833455
Hoorizad Ganjkar, Maryam; Heshmat, Haleh; Hassan Ahangari, Reza
2017-01-01
Statement of the Problem: Increasing the thickness of the veneering porcelain may affect the polymerization of resin cements. Incomplete polymerization of resin cements can lead to compromised quality of restoration and decrease the longevity of indirect restorations. Purpose: This study sought to assess the effect of IPS Empress porcelain thickness on the degree of conversion of light-cure and dual-cure resin cements using Fourier transform infrared spectroscopy. Materials and Method: In this experimental study, IPS Empress porcelain discs (A2 shade) with 10mm diameter and 0.5, 1 and 1.5 mm thicknesses were fabricated. Choice2 (Bisco, USA) and Nexus3 (Kerr, USA) resin cements were light cured through the three porcelain thicknesses in two groups of 3 samples using a LED light-curing unit (LEDemetron II; Kerr, USA). The control group samples were cured individually with no porcelain disc. The degree of conversion of resin cements was determined using FTIR (Bruker; Equinox55, Germany). The data were analyzed using Dunn’s test. Results: The degree of conversion (in percent) beneath the 0.5, 1.5 and 2 mm thicknesses of IPS Empress was 68.67±0.88, 71.06±0.94 and 72.51±0.41 for Choice2 resin cement and 69.60±2.12, 69.64±1.63 and 69.24±2.12 for Nexus3, respectively. Porcelain thickness and type of resin cement had no significant effect on degree of conversion (p≥ 0.05). Conclusion: It seems that increasing the porcelain thickness by up to 1.5 mm has no adverse effect on degree of conversion of both dual cure and light cure resin cements evaluated in this study. PMID:28280757
Souza-Junior, Eduardo José; Borges, Boniek Castillo Dutra; Montes, Marcos Antônio Japiassú Resende; Alonso, Roberta Caroline Bruschi; Ambrosano, Glaucia Maria Bovi; Sinhoreti, Mário Alexandre Coelho
2012-01-01
This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.
Using cure models for analyzing the influence of pathogens on salmon survival
Ray, Adam R; Perry, Russell W.; Som, Nicholas A.; Bartholomew, Jerri L
2014-01-01
Parasites and pathogens influence the size and stability of wildlife populations, yet many population models ignore the population-level effects of pathogens. Standard survival analysis methods (e.g., accelerated failure time models) are used to assess how survival rates are influenced by disease. However, they assume that each individual is equally susceptible and will eventually experience the event of interest; this assumption is not typically satisfied with regard to pathogens of wildlife populations. In contrast, mixture cure models, which comprise logistic regression and survival analysis components, allow for different covariates to be entered into each part of the model and provide better predictions of survival when a fraction of the population is expected to survive a disease outbreak. We fitted mixture cure models to the host–pathogen dynamics of Chinook Salmon Oncorhynchus tshawytscha and Coho Salmon O. kisutch and the myxozoan parasite Ceratomyxa shasta. Total parasite concentration, water temperature, and discharge were used as covariates to predict the observed parasite-induced mortality in juvenile salmonids collected as part of a long-term monitoring program in the Klamath River, California. The mixture cure models predicted the observed total mortality well, but some of the variability in observed mortality rates was not captured by the models. Parasite concentration and water temperature were positively associated with total mortality and the mortality rate of both Chinook Salmon and Coho Salmon. Discharge was positively associated with total mortality for both species but only affected the mortality rate for Coho Salmon. The mixture cure models provide insights into how daily survival rates change over time in Chinook Salmon and Coho Salmon after they become infected with C. shasta.
Braga, Andrea; Caccia, Giorgio; Sorice, Paola; Cantaluppi, Simona; Coluccia, Anna Chiara; Di Dedda, Maria Carmela; Regusci, Luca; Ghezzi, Fabio; Uccella, Stefano; Serati, Maurizio
2018-07-01
To assess the efficacy and safety of retropubic tension-free vaginal tape (TVT) 17 years after implantation for the treatment of female pure stress urinary incontinence (SUI). A prospective study was conducted in two urogynaecological units in two countries. All consecutive women with urodynamically proven pure SUI treated by TVT were included. Patients with mixed incontinence and/or anatomical evidence of pelvic organ prolapse were excluded. Data regarding subjective outcomes (International Consultation on Incontinence Questionnaire-Short Form, Patient Global Impression of Improvement, and patient satisfaction scores), objective cure (stress test) rates, and adverse events were collected during follow-up. Univariable analysis was performed to investigate outcomes. A total of 52 women underwent TVT implantation. At 17-year follow-up, 46 women (88.4%) were available for the evaluation. We did not find any significant change in surgical outcomes during this time. At 17 years after surgery, 41 of 46 women (89.1%) declared themselves cured (P = 0.98). Similarly, at 17-year evaluation, 42 of 46 women (91.4%) were objectively cured. No significant deterioration in objective cure rates was observed over time (P for trend 0.50). The univariate analysis did not find any risk factor statistically associated with the recurrence of SUI. Of the 46 women, 15 (32.6%) reported the onset of de novo overactive bladder at 17-year follow-up. No other late complications were reported. The 17-year results of this study showed that TVT is a highly effective and safe option for the treatment of SUI. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
When Kids Want Too Much: Curing a Case of the "Gimmies."
ERIC Educational Resources Information Center
Villaire, Ted
2001-01-01
Asserts that as parents spend less time with their children and try to assuage their guilt by buying children things, the many effects of materialism must be prevented. Children need help understanding that spending time with friends and family is more rewarding than spending money. They need to be taught the strategies of media literacy while…
van den Borne, B H P; van Schaik, G; Lam, T J G M; Nielen, M
2010-01-01
Two linked randomized field trials were performed on 39 herds in the Netherlands to 1) determine therapeutic effects of antimicrobial treatment of recently acquired subclinical mastitis (RASCM) during lactation, 2) evaluate the effect of duration of subclinical mastitis on therapeutic outcome, and 3) identify factors related to the therapeutic success of RASCM. Cows with a first elevated composite somatic cell count (CSCC) after 2 consecutive low CSCC measurements were eligible for enrollment in trial 1 (treatment at the first elevated CSCC). Quarter milk samples were collected to determine bacteriological status for major pathogens and coagulase-negative staphylococci. Cows with one or more culture-positive quarters with a quarter somatic cell count (QSCC) >or=100,000 cells/mL were defined to have RASCM and were randomly assigned treatment or control (no treatment). Untreated cows from trial 1 that had a second elevated CSCC at the next milk recording were eligible for enrollment in trial 2 (treatment at the second elevated CSCC). In trial 2, staphylococci-positive cows (Staphylococcus aureus and coagulase-negative staphylococci) were randomly assigned to treatment or control. Farmers used their own treatment protocols to treat quarters in both trials. Bacteriological cure was defined as absence of the pathogen identified pre-intervention in 2 samples post-intervention; QSCC, CSCC, and milk yield were also analyzed. Hierarchical logistic and linear models were used to determine therapeutic effects and to identify factors related to therapy outcome. Treated quarters had a higher bacteriological cure rate than control quarters for all pathogens in both trials. Treatment resulted in lower QSCC and CSCC, whereas milk yield was not affected by treatment. Bacteriological cure of RASCM was better in quarters with a low QSCC pre-intervention and in coagulase-negative staphylococci-positive quarters. Control quarters with a single culture-positive sample pre-intervention also had a higher bacteriological cure than control quarters with >or=2 culture-positive samples. Time of antimicrobial treatment affected bacteriological cure for penicillin-sensitive Staph. aureus. Bacteriological cure tended to be higher for Staph. aureus after treatment at the first elevated CSCC compared with treatment at the second elevated CSCC. Thus, early treatment of Staph. aureus might be more effective than later treatment. Copyright 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Tsujimoto, Akimasa; Barkmeier, Wayne W; Takamizawa, Toshiki; Latta, Mark A; Miyazaki, Masashi
2017-03-31
The purpose of this study was to investigate the depth of cure, flexural properties and volumetric shrinkage of low and high viscosity bulk-fill giomers and resin composites. Depth of cure and flexural properties were determined according to ISO 4049, and volumetric shrinkage was measured using a dilatometer. The depths of cure of giomers were significantly lower than those of resin composites, regardless of photo polymerization times. No difference in flexural strength and modulus was found among either high or low viscosity bulk fill materials. Volumetric shrinkage of low and high viscosity bulk-fill resin composites was significantly less than low and high viscosity giomers. Depth of cure of both low and high viscosity bulk-fill materials is time dependent. Flexural strength and modulus of high viscosity or low viscosity bulk-fill giomer or resin composite materials are not different for their respective category. Resin composites exhibited less polymerization shrinkage than giomers.
Marko, Dritana; Calvet, Xavier; Ducons, Julio; Guardiola, Jordi; Tito, Llucia; Bory, Felipe
2005-02-01
First-line proton pump inhibitor-based triple and quadruple therapies for Helicobacter pylori eradication present similar levels of efficacy. Cross-over treatment (quadruple following triple failure, and triple following quadruple failure) seems the most sensible approach to treatment failures, but the two strategies -'quadruple first' versus 'triple first'- have not been previously compared. The aims of our study were to assess the usefulness and the cost-effectiveness of the two treatment strategies. Forty-nine out of 344 patients included in a previous study comparing triple therapy - 7 days of omeprazole, amoxicillin and clarithromycin twice a day - with quadruple therapy - 7 days of omeprazole twice a day, plus tetracycline, metronidazole and bismuth subcitrate three times a day - failed initial treatment and were assigned to cross-over therapy. Cure was determined by urea breath test. A decision analysis was performed to compare the two eradication strategies. Intention to treat cure rates were 46% (10/22 patients; 95% CI 24-68%) for second-line triple therapy and 63% (17/27 patients; 95% CI 42-81%) for second-line quadruple therapy. Per protocol cure rates were 71% and 85%, respectively. Intention to treat cure rates were 87% (95% CI 81-92%) for the 'triple first' versus 86% (95% CI 80-91%) for the 'quadruple first' strategy (p = .87). The 'quadruple first' strategy was more cost-effective. The incremental cost of 'triple first' strategy per person was 19 in the low-cost area and 65 US dollars in the high-cost area. The effectiveness of 'triple first' and 'quadruple first' strategies is similar, although the latter seems slightly more cost-effective.
Cordovil De Sousa Uva, Mariana; Luminet, Olivier; Cortesi, Marie; Constant, Eric; Derely, Marc; De Timary, Philippe
2010-01-01
The present study examined the effects of protracted alcohol withdrawal on affectivity, craving, selective attention and executive functions (EFs) in alcohol-dependent patients. Selective attention (The D2 Cancellation Test), flexibility (Trail Making Test), inhibition (Stroop Task), decision making (Iowa Gambling Task), craving (Obsessive-Compulsive Drinking Scale) and state affectivity (Positive and Negative Affectivity Schedule) were assessed in alcohol-dependent patients (DSM-IV, n = 35) matched to non-alcohol-dependent participants (n = 22) at the onset (T1: day 1 or 2) and at the end (T2: days 14-18) of protracted withdrawal during rehab. Alcohol-dependent patients' abilities to focus their attention on relevant information, to switch from one pattern to another, to inhibit irrelevant information and to make advantageous choices were lower than those of control participants during both times of a withdrawal cure. No effect of time emerged from analyses for selective attention and EF deficits. Conversely, significant differences between T1 and T2 were observed for craving and affect scores indicating a weakening of alcohol craving and negative affect as well as an improvement of positive affect among patients from onset to the end of cure. Control functions of the Supervisory Attentional System (Norman and Shallice, 1986) were impaired and did not improve during a 3-week withdrawal cure, whereas alcohol craving and negative state affectivity significantly improved in parallel during this period. Implications for understanding the clinical processes of withdrawal are discussed.
Ponzoni, Chiara; Lancellotti, Isabella; Barbieri, Luisa; Spinella, Alberto; Saladino, Maria Luisa; Martino, Delia Chillura; Caponetti, Eugenio; Armetta, Francesco; Leonelli, Cristina
2015-04-09
A class of inorganic binders, also known as geopolymers, can be obtained by alkali activation of aluminosilicate powders at room temperature. The process is affected by many parameters (curing time, curing temperature, relative humidity etc.) and leads to a resistant matrix usable for inertization of hazardous waste. In this study an industrial liquid waste containing a high amount of chromium (≈ 2.3 wt%) in the form of metalorganic salts is inertized into a metakaolin based geopolymer matrix. One of the innovative aspects is the exploitation of the water contained in the waste for the geopolymerization process. This avoided any drying treatment, a common step in the management of liquid hazardous waste. The evolution of the process--from the precursor dissolution to the final geopolymer matrix hardening--of different geopolymers containing a waste amount ranging from 3 to 20%wt and their capability to inertize chromium cations were studied by: i) the leaching tests, according to the EN 12,457 regulation, at different curing times (15, 28, 90 and 540 days) monitoring releases of chromium ions (Cr(III) and Cr(VI)) and the cations constituting the aluminosilicate matrix (Na, Si, Al); ii) the humidity variation for different curing times (15 and 540 days); iii) SEM characterization at different curing times (28 and 540 days); iv) the trend of the solution conductivity and pH during the leaching test; v) the characterization of the short-range ordering in terms of TOT bonds (where T is Al or Si) by (29)Si and (27)Al solid state magic-angle spinning nuclear magnetic resonance (ss MAS NMR) for geopolymers containing high amounts of waste (10-20%wt). The results show the formation of a stable matrix after only 15 days independently on the waste amount introduced; the longer curing times increase the matrices stabilities and their ability to immobilize chromium cations. The maximum amount of waste that can be inertized is around 10 wt% after a curing time of 28 days. Copyright © 2014 Elsevier B.V. All rights reserved.
Effects of silica-coated carbon nanotubes on the curing behavior and properties of epoxy composites
Li, Ao; Li, Weizhen; Ling, Yang; ...
2016-02-22
Multi-walled carbon nanotubes (MWCNTs) were coated with silica by a sol–gel method to improve interfacial bonding and dispersion of nanotubes in the diglycidyl ether of bisphenol A (DGEBA) matrix. TEM and FE-SEM measurements showed that the silica shell was successfully coated on the surface of r-MWCNTs (as-received MWCNTs), and that the dispersion of MWCNT@SiO 2 in the epoxy matrix and interfacial adhesion between MWCNTs and epoxy were improved through the silica shell formation. The effects of silica-coated multi-walled carbon nanotube (MWCNT@SiO 2) addition on the curing behavior of epoxy resin, and on the physical and thermomechanical properties of epoxy composites,more » were studied. FT-IR measurements of different blends at different curing times indicated that the curing reaction was accelerated with the presence of MWCNTs and increased with the content of MWCNT@SiO 2. DSC results confirmed that the value of activation energy decreased with the introduction of MWCNTs in the order of MWCNT@SiO 2 < r-MWCNTs < epoxy. It was found that the thermal conductivity of epoxy composites were significantly enhanced by incorporation of MWCNT@SiO 2, relative to composites with r-MWCNTs, while the values of the glass transition temperature slightly increased, and the high electrical resistivity of these composites was retained overall.« less
Bunichiro Tomita; Hideaki Osawa; Chung-Yun Hse; George E. Myers
1989-01-01
A nonconventional curing system was developed using a simple mixing of urea-formaldehyde (UF) resins with polyfunctional hydrazide compounds under neutral contition. Several kinds of low molecular-weight dihydrazide compounds were investigated as hardners of the UF resins. Results were as follows: 1) As the minimum gelation times were observed in the range of molar...
Photopolymerizable liquid encapsulants for microelectronic devices
NASA Astrophysics Data System (ADS)
Baikerikar, Kiran K.
2000-10-01
Plastic encapsulated microelectronic devices consist of a silicon chip that is physically attached to a leadframe, electrically interconnected to input-output leads, and molded in a plastic that is in direct contact with the chip, leadframe, and interconnects. The plastic is often referred to as the molding compound, and is used to protect the chip from adverse mechanical, thermal, chemical, and electrical environments. Encapsulation of microelectronic devices is typically accomplished using a transfer molding process in which the molding compound is cured by heat. Most transfer molding processes suffer from significant problems arising from the high operating temperatures and pressures required to fill the mold. These aspects of the current process can lead to thermal stresses, incomplete mold filling, and wire sweep. In this research, a new strategy for encapsulating microelectronic devices using photopolymerizable liquid encapsulants (PLEs) has been investigated. The PLEs consist of an epoxy novolac-based vinyl ester resin (˜25 wt.%), fused silica filler (70--74 wt.%), and a photoinitiator, thermal initiator, and silane coupling agent. For these encapsulants, the use of light, rather than heat, to initiate the polymerization allows precise control over when the reaction starts, and therefore completely decouples the mold filling and the cure. The low viscosity of the PLEs allows for low operating pressures and minimizes problems associated with wire sweep. In addition, the in-mold cure time for the PLEs is equivalent to the in-mold cure times of current transfer molding compounds. In this thesis, the thermal and mechanical properties, as well as the viscosity and adhesion of photopolymerizable liquid encapsulants, are reported in order to demonstrate that a UV-curable formulation can have the material properties necessary for microelectronic encapsulation. In addition, the effects of the illumination time, postcure time, fused silica loading, and the inclusion of a thermal initiator on the thermal and mechanical properties of the final cured encapsulants have been investigated. The results show that the material properties of the PLEs are the same, if not better, than those exhibited by conventional transfer molding compounds and demonstrate the potential of using PLEs for encapsulating microelectronic devices.
Kaneko, K
1989-09-01
A heating method using micro-waves was utilized to obtain strong thermosetting resin for crown and bridge. The physical and mechanical properties of the thermosetting resin were examined. The resin was cured in a shorter time by the micro-waves heating method than by the conventional heat curing method and the working time was reduced markedly. The base resins of the thermosetting resin for crown and bridge for the micro-waves heating method were 2 PA and diluent 3 G. A compounding volume of 30 wt% for diluent 3 G was considered good the results of compressive strength, bending strength and diametral tensile strength. Grams of 200-230 of the filler compounded to the base resins of 2 PA-3 G system provided optimal compressive strength, bending strength and diametral tensile strength. A filler gram of 230 provided optimal hardness and curing shrinkage rate, the coefficient of thermal expansion became smaller with the increase of the compounding volume of the filler. The trial thermosetting resin for crown and bridge formed by the micro-waves heating method was not inferior to the conventional resin by the heat curing method or the light curing method.
Pre-cure freezing effect on physicochemical, texture and sensory characteristics of Iberian ham.
Pérez-Palacios, T; Ruiz, J; Martín, D; Barat, J M; Antequera, T
2011-04-01
The aim of this work was to investigate the effect of pre-cure freezing on the physicochemical, texture and sensory characteristics of raw and dry-cured hams. Both, refrigerated (R) and pre-cure frozen (F) hams showed the same weight losses during the processing. At the green stage F Iberian hams had lower moisture content, higher values of a* and chroma, lower hardness and chewiness and higher adhesiveness and springiness than R ones. However, at the end of the processing R and F Iberian hams only were different in salt content, F hams showing lower values than R ones. Sensory analysis of Iberian dry-cured ham did not show differences in salty taste. Panelist detected a higher fat hardness and lean pastiness in F than in R hams. The overall acceptability for both groups of dry-cured hams was between average and good.
Ali, Shafqut; Iram, Samia
2009-01-01
Hepatitis C is major emerging challenge for pathologists and treating physicians all over the world. Already 10 million Pakistani population has become anti-HCV positive. It is not only affecting hepatobiliary system but with passage of time research is revealing that Hepatitis C is going to involve almost every organ of the body. With timely diagnosis and treatment, millions of patients can be saved from morbidity and mortality. The nation has to sacrifice initial economic allocations to avoid later millions of mortalities and greater economic losses on affected patients and to support their families. The objective of this study was to evaluate effectiveness of combine therapy of Hepatitis C in local population of Pakistan. This case series study was done at CMH Okara, Kohat, Abbottabad, and PAF Hospital, Shorkot from August 2000 to August 2009. All 1,000 patients from 10 to 60 years of age, confirmed anti-HCV Positive by ELISA and PCR Positive for HCV RNA, were subjected to Interferon alpha-2b and Ribavirin therapy for similar period of time. Response and adverse affects were observed by clinical examination, blood complete picture including platelet count and ALT fortnightly. PCR for HCV RNA and ultrasound abdomen (hepatobilliary system) was done quarterly during treatment and 6 monthly for 2 years after treatment to review the sustained response and relapse. Over all cure rate after 2 years was 855 (85.5%) excluding the 50 (5%) of initial resistant to one year treatment and 95 (9.5%) re-treated relapse cases. One hundred and forty-five (14.5%) patients were found to be resistant to treatment. Hepatitis C must be treated timely after proper diagnosis. Interferon and Ribavirin combination have shown high 'cure' rate in Hepatitis C. In spite of high cure rate of 85.5% with timely and proper treatment, low socio-economic status is a major problem for poor individuals to get treatment. Preventive aspect must be strictly followed and implemented.
Fuentes, Verónica; Utrera, Mariana; Estévez, Mario; Ventanas, Jesús; Ventanas, Sonia
2014-08-01
The effect of high hydrostatic pressure (HHP) (600MPa) and intramuscular fat content (IMF) on colour parameters and oxidative stability of lipids and proteins in sliced vacuum-packaged Iberian dry-cured ham during refrigerated storage (120 days at 2°C) was investigated. Several studies have investigated the influence of HHP on lipid oxidation of meat products. However, its effects on protein carbonylation, as also the influence of IMF content on this carbonylation are poorly understood. HHP treatment had a significant effect on lean lightness after 0 and 120 days of storage while IMF content increased lightness and yellowness over time. Regarding oxidative stability, the effect of HHP treatment depended on IMF content samples with a high IMF having greater lipid instability while samples with a low IMF underwent more protein carbonylation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Parvizi, Mohammad Mahdi; Moein, Mahmoodreza; Hatam, Gholamreza; Nimrouzi, Majid; Hassanzadeh, Jafar; Hamidizadeh, Nasrin; Khorrami, Hamid Reza; Zarshenas, Mohammad Mehdi
2017-01-01
Background Cutaneous leishmaniasis is one of the highly prevalent endemic diseases in the Middle East and North Africa. Many treatment modalities have been recommended for this condition but success rates remain limited. Herbal remedies have also been used for treatment but evidence-based clinical trials with these products are sparse. In-vitro and in-vivo studies have shown the anti-leishmanial and curative effects of extract of fruits and leaves of Juniperus excelsa (J. excelsa). The aim of this study was to determine the efficacy of topical J. excelsa M. Bieb extract as an adjuvant to cryotherapy for the treatment of human CL. Materials and methods This study was designed as a two-arm triple-blind randomized placebo-controlled clinical trial using a parallel design. Seventy-two patients with clinical diagnosis of CL confirmed by leishmania smears were allocated to receive either a topical formulation of leaf of J. excelsa extract (group A) or placebo (group B) for 3 months. Both groups received cryotherapy as baseline standard treatment. Patients were evaluated before and weekly after the intervention was initiated until complete cure. Results Overall, 82% of patients in group A, experienced complete cure and 9% of them had partial cure. On the other hand, 34% in group B reported complete cure, while 14% of them had partial cure at the end of treatment protocol with a significant difference between the two groups (P< 0.001). The mean duration to healing of the lesions in patients who received J. excelsa extract was statistically significantly shorter than the placebo group (p = 0.04). No significant side effect was seen in the J. excelsa extract group except for mild to moderate local irritation after a few weeks in a few numbers of patients. Conclusion The results of this study showed that topical J. excelsa extract can be used as an adjuvant treatment modality in addition to cryotherapy for accelerating the time to cure in addition to increasing the complete cure rate in CL. Trial registration ClinicalTrials.gov IRCT2015082523753N1 PMID:28981503
Ito, Yuri; Nakayama, Tomio; Tsukuma, Hideaki; Miyashiro, Isao; Ioka, Akiko; Sugimoto, Tomoyuki; Rachet, Bernard
2012-04-01
To evaluate progress in stomach cancer care in Japan since 1975. Population-based study of data extracted from the Osaka Cancer Registry. Population-based cancer registry in the area of Osaka Prefecture. All 66,032 cases diagnosed with a stomach cancer in Osaka Prefecture, Japan between 1975 and 2000 and registered in the Osaka Cancer Registry. 'Cure' fraction and median survival time for 'uncured' patients were estimated with multivariable mixture 'cure' model. The role played by age and stage at diagnosis on the changes in 'cure' parameters between 1975 and 2000 was evaluated. Missing stage was handled by multiple imputation approach. More than 50% of the patients diagnosed with a stomach cancer in 1996-2000 were estimated 'cured' from their cancer, corresponding to a 20% increase since 1975-1980. Median survival time for 'uncured' patients however remained unchanged at about 8 months. 'Cure' fraction was over 85% for localised tumours and 30% for regional tumours, but stayed as low as 2.5% for distant metastatic cancers. Improvement was underestimated by about 10% because of ageing of cancer patients. Changes in stage distribution explained up to 40% of the increase in 'cure' fraction among men and up to 13% in women. Overdiagnosis was unlikely to play any role in these patterns. 'Cure' fraction from stomach cancer dramatically increased in Osaka, Japan since 1975, partly because of earlier stage at diagnosis, but mostly due to improvement in treatment of stomach cancer patients. This study, based on a leading country in term of stomach cancer management, provides insightful results for other countries in which 'cure' fraction is usually much lower. Copyright © 2012 Elsevier Ltd. All rights reserved.
Relapse after Oral Terbinafine Therapy in Dermatophytosis: A Clinical and Mycological Study.
Majid, Imran; Sheikh, Gousia; Kanth, Farhath; Hakak, Rubeena
2016-01-01
The incidence of recurrent tinea infections after oral terbinafine therapy is on the rise. This study aims to identify the appearance of incomplete cure and relapse after 2-week oral terbinafine therapy in tinea corporis and/or tinea cruris. A total of 100 consecutive patients clinically and mycologically diagnosed to have tinea corporis and/or tinea cruris were included in the study. The enrolled patients were administered oral terbinafine 250 mg once daily for 2 weeks. All clinically cured patients were then followed up for 12 weeks to look for any relapse/cure. The common dermatophytes grown on culture were Trichophyton rubrum and Trichophyton tonsurans in 55% and 20% patients, respectively. At the end of 2-week oral terbinafine therapy, 30% patients showed a persistent disease on clinical examination while 35% patients showed a persistent positive fungal culture (persisters) at this time. These culture positive patients included all the clinically positive cases. Rest of the patients (65/100) demonstrated both clinical and mycological cure at this time (cured). Over the 12-week follow-up, clinical relapse was seen in 22 more patients (relapse) among those who had shown clinical and mycological cure at the end of terbinafine therapy. Thus, only 43% patients could achieve a long-term clinical and mycological cure after 2 weeks of oral terbinafine treatment. Majority of the relapses (16/22) were seen after 8 weeks of completion of treatment. There was no statistically significant difference in the body surface area involvement or the causative organism involved between the cured, persister, or relapse groups. Incomplete mycological cure as well as relapse is very common after standard (2-week) terbinafine therapy in our patients of tinea cruris/corporis.
USDA-ARS?s Scientific Manuscript database
The objective was: 1) to characterize the effect of marketing 30 group on fresh and cured ham quality, and 2) to determine which fresh ham traits correlated to cured ham quality traits. Pigs raised in 8 barns representing two seasons (hot and cold) and two production focuses (lean and quality) were ...
Characterization of the relationship of the cure cycle chemistry to cure cycle processing properties
NASA Technical Reports Server (NTRS)
Kranbuehl, D. E.
1985-01-01
Dynamic dielectric analysis (DDA) is used to study curing polymer systems and thermoplastics. Measurements are made over a frequency range of six decades. This wide range of frequencies increases the amount of information which can be obtained. The data is analyzed in terms of the frequency dependence of the complex permittivity epsilon sup *, specific conductivity sigma (ohm/cm) and the relaxation time tau, parameters which are characteristic of the cure state of the material and independent of the size of the sample.
2008-01-01
Background The primary objective of this study was to investigate if supplementary lactobacilli treatment could improve the initial cure rate after vaginal clindamycin therapy, and secondly, if lactobacilli as repeated adjunct treatment during 3 menstrual cycles could lengthen the time to relapse after initial cure. Methods Women (n = 100) with bacterial vaginosis diagnosed by Amsel criteria were after informed consent offered vaginal clindamycin therapy followed by vaginal gelatine capsules containing either 109 freeze-dried lactobacilli or identical placebo capsules for 10 days during 3 menstrual cycles in a double-blind, randomized, placebo-controlled trial. Results The initial intent to treat (ITT) analysis for the one-month cure rate was 64% in the lactobacilli group and 78% in the placebo group (p > 0.05). However, any patient with missing or unclassified smears at the initial visit who continued the study and whose next smear indicated a cure was included in the cured group; the study also excluded two of the patients in the lactobacilli group who reported that they did not take any vaginal capsules. With consideration to these population changes, the initial cure rate would be 77% in the lactobacilli group. The 76 cured women were followed for 6 menstrual cycles or until relapse within that time span. At the end of the study, 64.9% (24/37) of the lactobacilli treated women were still BV-free compared to 46.2% (18/39) of the placebo treated women. Comparison of the two groups regarding "Time from cure to relapse" was statistically significant (p = 0.027) in favour of the lactobacilli treatment. Adjuvant therapy with lactobacilli contributed significantly to avoidance of relapse with a proportional Hazard Risk ratio (HR) of 0.73 (0.54–0.98) (p < 0.05) Conclusion The study shows that supplementary treatment combining two different strains of probiotic lactobacilli does not improve the efficacy of BV therapy during the first month of treatment, but for women initially cured, adjunct treatment of lactobacilli during 3 menstrual cycles lengthens the time to relapse significantly in that more women remained BV free at the end of the 6-month follow up. Trial registration number ISRCTN62879834 PMID:18197974
Hwang, Ko-Eun
2017-01-01
The effect of fermented spinach extracts on color development in cured meats was investigated in this study. The pH values of raw cured meats without addition of fermented spinach extract or nitrite (negative control) were higher (p<0.05) than those added with fermented spinach extract. The pH values of raw and cooked cured meats in treatment groups were decreased with increasing addition levels of fermented spinach extract. The lightness and yellowness values of raw cured meats formulated with fermented spinach extract were higher (p<0.05) than those of the control groups (both positive and negative controls). The redness values of cooked cured meats were increased with increasing fermented spinach extract levels, whereas the yellowness values of cooked cured meats were decreased with increasing levels of fermented spinach extract. The lowest volatile basic nitrogen (VBN) and thiobarbituric acid reactive substances (TBARS) values were observed in the positive control group with addition of nitrite. TBARS values of cured meats added with fermented spinach extract were decreased with increasing levels of fermented spinach extract and VBN values of curing meat with 30% fermented spinach extract was lower than the other treatments. Total viable bacterial counts in cured meats added with fermented spinach extract ranged from 0.34-1.01 Log CFU/g. E. coli and coliform bacteria were not observed in any of the cured meats treated with fermented spinach extracts or nitrite. Residual nitrite contents in treatment groups were increased with increasing levels of fermented spinach extract added. These results demonstrated that fermented spinach could be added to meat products to improve own curing characteristics. PMID:28316477
Kim, Tae-Kyung; Kim, Young-Boong; Jeon, Ki-Hong; Park, Jong-Dae; Sung, Jung-Min; Choi, Hyun-Wook; Hwang, Ko-Eun; Choi, Yun-Sang
2017-01-01
The effect of fermented spinach extracts on color development in cured meats was investigated in this study. The pH values of raw cured meats without addition of fermented spinach extract or nitrite (negative control) were higher ( p <0.05) than those added with fermented spinach extract. The pH values of raw and cooked cured meats in treatment groups were decreased with increasing addition levels of fermented spinach extract. The lightness and yellowness values of raw cured meats formulated with fermented spinach extract were higher ( p <0.05) than those of the control groups (both positive and negative controls). The redness values of cooked cured meats were increased with increasing fermented spinach extract levels, whereas the yellowness values of cooked cured meats were decreased with increasing levels of fermented spinach extract. The lowest volatile basic nitrogen (VBN) and thiobarbituric acid reactive substances (TBARS) values were observed in the positive control group with addition of nitrite. TBARS values of cured meats added with fermented spinach extract were decreased with increasing levels of fermented spinach extract and VBN values of curing meat with 30% fermented spinach extract was lower than the other treatments. Total viable bacterial counts in cured meats added with fermented spinach extract ranged from 0.34-1.01 Log CFU/g. E. coli and coliform bacteria were not observed in any of the cured meats treated with fermented spinach extracts or nitrite. Residual nitrite contents in treatment groups were increased with increasing levels of fermented spinach extract added. These results demonstrated that fermented spinach could be added to meat products to improve own curing characteristics.
Zhao, Gui-Hong; Yu, Yan-Ling; Zhou, Xiang-Tong; Lu, Bin-Yu; Li, Zi-Mu; Feng, Yu-Jie
2017-05-01
The main characteristic of discarded flue-cured tobacco leaves is their high nicotine content. Aerobic composting is an effective method to decrease the nicotine level in tobacco leaves and stabilize tobacco wastes. However, high levels of nicotine in discarded flue-cured tobacco leaves complicate tobacco waste composting. This work proposes a drying pretreatment process to reduce the nicotine content in discarded flue-cured tobacco leaves and thus enhance its carbon-to-nitrogen ratio to a suitable level for composting. The effect of another pretreatment method, particle size adjustment, on composting efficiency was also tested in this work. The results indicated that the air-dried (nicotine content: 1.35%) and relatively long discarded flue-cured tobacco leaves (25 mm) had a higher composting efficiency than damp (nicotine content: 1.57%) and short discarded flue-cured tobacco leaves (15 mm). When dry/25 mm discarded flue-cured tobacco leaves mixed with tobacco stems in an 8:2 ratio was composted at a temperature above 55 °C for 9 days, the nicotine content dropped from 1.29% to 0.28%. Since the discarded flue-cured tobacco leaves was successfully composted to a fertile and harmless material, the germination index values increased to 85.2%. The drying pretreatment and particle size adjustment offered ideal physical and chemical conditions to support microbial growth and bioactivity during the composting process, resulting in efficient conversion of discarded flue-cured tobacco leaves into a high quality and mature compost.
Solid freeform fabrication of biomaterials
NASA Astrophysics Data System (ADS)
Chu, Tien-Min Gabriel
1999-12-01
The biological performance of porous Hydroxyapatite (HA) is closely related to the pore architecture in the implants. The study on the effect of architecture to the biological performance of porous HA requires new manufacturing methods that can fabricate implants with controlled pores channels. In this thesis, four highly loaded HA and alumina suspensions were formulated and three different processes involving Solid Freeform Fabrication (SFF) were developed. An aqueous HA suspension in acrylamides was first formulated and the UV-curing properties were evaluated. With a medical grade HA powder, two non-aqueous HA suspensions were formulated: a 40 vol.% HA suspension in Hexanediol Diacrylate (HDDA) and a 40 vol.% HA suspension in 1:1 mix of Propoxylated Neopentyl Glycol Diacrylate (PNPGDA) and Isobomyl Acrylate (EBA). A 50 vol.% Alumina suspension in PNPGDA/IBA was also formulated. The effect of dispersant to the viscosity of the suspensions was characterized. In the Stereolithography (SL) method, the curing parameters of HA/HDDA and HA/PNPGDA/IBA were determined. Prototype HA implants with 1,700 mum internal channels were built directly on an SL Apparatus (SLA). The designed internal channel patterns were preserved after sintering. In the Ink-jet printing method, the high temperature flow behaviors of the suspensions were characterized. The effects of solids loading to the viscosity of the suspensions were modeled with Krieger-Dougherty equation. Leveling theory developed in paint industry was employed to analyze the self-leveling capability of the suspensions. In the indirect SL method, the thermal curing behavior of HA and alumina suspensions were characterized. The total cure time was measured and the curing kinetics was modeled. Negative molds for the implants were designed and built on SLA with epoxy resin. HA/PNPGDA/IBA was cast into the mold and cured in an oven. The binders and the epoxy mold were pyrolyzed and the green bodies sintered. Internal channels with sizes in the range of 420 to 968 gm with standard deviation less than 50 mum were successfully built. The formulation and characterization techniques developed in this thesis were useful for evaluating the suspensions for SFF process. The manufacturing process developed in this thesis have provided new methods for controlling the channel size in porous HA implants.
Namnabat, Soha; Kim, Kyung-Jo; Jones, Adam; Himmelhuber, Roland; DeRose, Christopher T; Trotter, Douglas C; Starbuck, Andrew L; Pomerene, Andrew; Lentine, Anthony L; Norwood, Robert A
2017-09-04
Silicon photonics has gained interest for its potential to provide higher efficiency, bandwidth and reduced power consumption compared to electrical interconnects in datacenters and high performance computing environments. However, it is well known that silicon photonic devices suffer from temperature fluctuations due to silicon's high thermo-optic coefficient and therefore, temperature control in many applications is required. Here we present an athermal optical add-drop multiplexer fabricated from ring resonators. We used a sol-gel inorganic-organic hybrid material as an alternative to previously used materials such as polymers and titanium dioxide. In this work we studied the thermal curing parameters of the sol-gel and their effect on thermal wavelength shift of the rings. With this method, we were able to demonstrate a thermal shift down to -6.8 pm/°C for transverse electric (TE) polarization in ring resonators with waveguide widths of 325 nm when the sol-gel was cured at 130°C for 10.5 hours. We also achieved thermal shifts below 1 pm/°C for transverse magnetic (TM) polarization in the C band under different curing conditions. Curing time compared to curing temperature shows to be the most important factor to control sol-gel's thermo-optic value in order to obtain an athermal device in a wide temperature range.
Li, Lei; Yang, Min; Luo, Jun; Qu, Qing; Chen, Ying; Liang, Lianming; Zhang, Keqin
2016-11-01
In soil, nematode-trapping fungi and bacteria often share microhabitats and interact with each other, but effects of fungus-associated bacteria on its trap formation are underestimated. We have ascertained the presence of Stenotrophomonas and Rhizobium genera associated with A. oligospora GJ-1. After A. oligospora GJ-1 without associated bacteria (cured Arthrobotrys) was co-cultivated with Stenotrophomonas and its supernatant extract, microscopic study of hyphae from co-cultivation indicated that bacterial biofilm formation on hyphae was related to trap formation in fungi and Stenotrophomonas supernatant extract. Four diketopiperazines (DKPs) were purified from Stenotrophomonas supernatant extract that could not induce traps in the cured Arthrobotrys. When cured Arthrobotrys was cultured with Stenotrophomonas and one of DKPs, polar attachment, bacterial biofilms on hyphae and trap formation in fungi were observed. After cured Arthrobotrys with bacterial biofilms was consecutively transferred several times on nutrient poor medium, trap formation disappeared with the disappearance of bacterial biofilms on hyphae. DKPs could facilitate chemotaxis of Stenotrophomonas towards fungal extract which was suggested to contribute to bacterial biofilms on hyphae. Furthermore, when cured Arthrobotrys was cultured with Stenotrophomonas and DKPs in soil, trap formation in fungi and bacterial biofilms on hyphae were also observed, and the fungal activity against nematode was enhanced. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.
Patients cured of acromegaly do not experience improvement of their skull deformities.
Rick, Jonathan W; Jahangiri, Arman; Flanigan, Patrick M; Aghi, Manish K
2017-04-01
Acromegaly is a rare disease that is associated with many co-morbidities. This condition also causes progressive deformity of the skull which includes frontal bossing and cranial thickening. Surgical and/or medical management can cure this condition in many patients, but it is not understood if patients cured of acromegaly experience regression of their skull deformities. We performed a retrospective analysis on patients treated at our dedicated pituitary center from 2009 to 2014. We looked at all MRI images taken during the treatment of these patients and recorded measurements on eight skull dimensions. We then analyzed these measurements for changes over time. 29 patients underwent curative treatment for acromegaly within our timeframe. The mean age for this population was 45.0 years old (range 19-70) and 55.2 % (n = 16) were female. All of these patients were treated with a transsphenoidal resection for a somatotropic pituitary adenoma. 9 (31.1%) of these patients required further medical therapy to be cured. We found statically significant variation in the coronal width of the sella turcica after therapy, which is likely attributable to changes from transsphenoidal surgery. None of the other dimensions had significant variation over time after cure. Patients cured of acromegaly should not expect natural regression of their skull deformities. Our study suggests that both frontal bossing and cranial thickening do not return to normal after cure.
Study on potential of carbon dioxide absorption in reinforced concrete beams
NASA Astrophysics Data System (ADS)
Bambroo, Vibhas; Gupta, Shipali; Bhoite, Pratik; Sekar, S. K.
2017-11-01
The global gas emission is keeping on increasing for which cement industry alone contributes 5%. The enormous water is required for curing of concrete in construction industry which can effectively be used for various purposes. The accelerated carbonation curing shows a way to reduce these emissions in a very effective way by sequestering it in concrete elements. In this research the effect of accelerated carbonation curing was checked on non-reinforced concrete elements (cubes) and reinforced concrete elements (prisms). The 100mm × 100mm × 100 mm cubes and 150mm × 150mm × 1200mm prisms were cast. They were CO2 cured for 4 and 8 hours and were tested for compressive strength and flexural strength test. The CO2 curing results showed 27.7% and 1.8% increase in strength of cubes and prisms, respectively when compared to water cured specimens. This early age strength through waste gas proves beneficial in terms of reducing in atmospheric pollution and saving the water which is a critical resource now-a-days.
Low voltage polymer network liquid crystal for infrared spatial light modulators.
Peng, Fenglin; Xu, Daming; Chen, Haiwei; Wu, Shin-Tson
2015-02-09
We report a low-voltage and fast-response polymer network liquid crystal (PNLC) infrared phase modulator. To optimize device performance, we propose a physical model to understand the curing temperature effect on average domain size. Good agreement between model and experiment is obtained. By optimizing the UV curing temperature and employing a large dielectric anisotropy LC host, we have lowered the 2π phase change voltage to 22.8V at 1.55μm wavelength while keeping response time at about 1 ms. Widespread application of such a PNLC integrated into a high resolution liquid-crystal-on-silicon (LCoS) for infrared spatial light modulator is foreseeable.
Cure of cancer for seven cancer sites in the Flemish Region.
Silversmit, Geert; Jegou, David; Vaes, Evelien; Van Hoof, Elke; Goetghebeur, Els; Van Eycken, Liesbet
2017-03-01
Cumulative relative survival curves for many cancers reach a plateau several years after diagnosis, indicating that the cancer survivor group has reached "statistical" cure. Parametric mixture cure model analysis on grouped relative survival curves provide an interesting way to determine the proportion of statistically cured cases and the mean survival time of the fatal cases in particular for population-based cancer registries. Based on the relative survival data from the Belgian Cancer Registry, parametric cure models were applied to seven cancer sites (cervix, colon, corpus uteri, skin melanoma, pancreas, stomach and oesophagus), at the Flemish Regional level for the incidence period 1999-2011. Statistical cure was observed for the examined cancer sites except for oesophageal cancer. The estimated cured proportion ranged from 5.9% [5.7, 6.1] for pancreatic cancer to 80.8% [80.5, 81.2] for skin melanoma. Cure results were further stratified by gender or age group. Stratified cured proportions were higher for females compared to males in colon cancer, stomach cancer, pancreas cancer and skin melanoma, which can mainly be attributed to differences in stage and age distribution between both sexes. This study demonstrates the applicability of cure rate models for the selected cancer sites after 14 years of follow-up and presents the first population-based results on the cure of cancer in Belgium. © 2016 UICC.
Highlights from the HIV Cure and Reservoir Symposium, 11-12 September 2017, Ghent, Belgium.
Kint, Sam; Van Hecke, Clarissa; Cole, Basiel; Vandekerckhove, Linos; Sips, Magdalena
2018-01-01
For the second time, the HIV Cure Research Center (HCRC) at Ghent University organised the HIV Cure and Reservoir Symposium, in Ghent, Belgium, where in this two-day conference, virologists, molecular biologists, immunologists and clinicians presented the most recent achievements in the field of HIV cure, including data on therapeutic vaccines, HIV remission strategies such as 'shock and kill' or 'block and lock', benefits of early ART and potential of haematopoietic stem cell transplant in achieving cure. Furthermore, methods to characterise and quantify the HIV reservoir were discussed along with HIV reservoir characterisation in different body parts, including the central nervous system. An HIV activist and representative of a patients' agency also presented the patients' perspective on HIV cure. This report is a summary of all topics discussed during this symposium.
Khan, Aftab A; Al-Kheraif, Abdulaziz A; Al-Shehri, Abdullah M; Säilynoja, Eija; Vallittu, Pekka K
2018-02-01
This laboratory study was aimed to characterize semi-interpenetrating polymer network (semi-IPN) of fiber-reinforced composite (FRC) prepregs that had been stored for up to two years before curing. Resin impregnated prepregs of everStick C&B (StickTech-GC, Turku, Finland) glass FRC were stored at 4°C for various lengths of time, i.e., two-weeks, 6-months and 2-years. Five samples from each time group were prepared with a light initiated free radical polymerization method, which were embedded to its long axis in self-curing acrylic. The nanoindentation readings on the top surface toward the core of the sample were made for five test groups, which were named as "stage 1-5". To evaluate the nanohardness and modulus of elasticity of the polymer matrix, a total of 4 slices (100µm each) were cut from stage 1 to stage 5. Differences in nanohardness values were evaluated with analysis of variance (ANOVA), and regression model was used to develop contributing effect of the material's different stages to the total variability in the nanomechanical properties. Additional chemical and thermal characterization of the polymer matrix structure of FRC was carried out. It was hypothesized that time of storage may have an influence on the semi-IPN polymer structure of the cured FRC. The two-way ANOVA test revealed that the storage time had no significant effect on the nanohardness of FRC (p = 0.374). However, a highly significant difference in nanohardness values was observed between the different stages of FRC (P<0.001). The regression coefficient suggests nanohardness increased on average by 0.039GPa for every storage group. The increased nanohardness values in the core region of 6-months and 2-years stored prepregs might be due to phase-segregation of components of semi-IPN structure of FRC prepregs before their use. This may have an influence to the surface bonding properties of the cured FRC. Copyright © 2017 Elsevier Ltd. All rights reserved.
Long-Term Mechanical Behavior of Nano Silica Sol Grouting
Zhang, Nong; Zhang, Chenghao; Qian, Deyu; Han, Changliang; Yang, Sen
2018-01-01
The longevity of grouting has a significant effect on the safe and sustainable operation of many engineering projects. A 500-day experiment was carried out to study the long-term mechanical behavior of nano silica sol grouting. The nano silica sol was activated with different proportions of a NaCl catalyst and cured under fluctuating temperature and humidity conditions. The mechanical parameters of the grout samples were tested using an electrohydraulic uniaxial compression tester and an improved Vicat instrument. Scanning electron microscope, X-ray diffraction, and ultrasonic velocity tests were carried out to analyze the strength change micro-mechanism. Tests showed that as the catalyst dosage in the grout mix is decreased, the curves on the graphs showing changes in the weight and geometric parameters of the samples over time could be divided into three stages, a shrinkage stage, a stable stage, and a second shrinkage stage. The catalyst improved the stability of the samples and reduced moisture loss. Temperature rise was also a driving force for moisture loss. Uniaxial compressive stress-strain curves for all of the samples were elastoplastic. The curves for uniaxial compression strength and secant modulus plotted against time could be divided into three stages. Sample brittleness increased with time and the brittleness index increased with higher catalyst dosages in the latter part of the curing time. Plastic strength-time curves exhibit allometric scaling. Curing conditions mainly affect the compactness, and then affect the strength. PMID:29337897
Fiber Reinforced Polyester Resins Polymerized by Microwave Source
NASA Astrophysics Data System (ADS)
Visco, A. M.; Calabrese, L.; Cianciafara, P.; Bonaccorsi, L.; Proverbio, E.
2007-12-01
Polyester resin based composite materials are widely used in the manufacture of fiberglass boats. Production time of fiberglass laminate components could be strongly reduced by using an intense energy source as well as microwaves. In this work a polyester resin was used with 2% by weight of catalyst and reinforced with chopped or woven glass fabric. Pure resin and composite samples were cured by microwaves exposition for different radiation times. A three point bending test was performed on all the cured samples by using an universal testing machine and the resulting fracture surfaces were observed by means of scanning electron microscopy (SEM). The results of mechanical and microscopy analyses evidenced that microwave activation lowers curing time of the composite while good mechanical properties were retained. Microwaves exposition time is crucial for mechanical performance of the composite. It was evidenced that short exposition times suffice for resin activation while long exposure times cause fast cross linking and premature matrix fracture. Furthermore high-radiation times induce bubbles growth or defects nucleation within the sample, decreasing composite performance. On the basis of such results microwave curing activation of polyester resin based composites could be proposed as a valid alternative method for faster processing of laminated materials employed for large-scale applications.
Bayesian transformation cure frailty models with multivariate failure time data.
Yin, Guosheng
2008-12-10
We propose a class of transformation cure frailty models to accommodate a survival fraction in multivariate failure time data. Established through a general power transformation, this family of cure frailty models includes the proportional hazards and the proportional odds modeling structures as two special cases. Within the Bayesian paradigm, we obtain the joint posterior distribution and the corresponding full conditional distributions of the model parameters for the implementation of Gibbs sampling. Model selection is based on the conditional predictive ordinate statistic and deviance information criterion. As an illustration, we apply the proposed method to a real data set from dentistry.
Seman, D L; Quickert, S C; Borger, A C; Meyer, J D
2008-07-01
The effect of sodium benzoate (0.08 to 0.25%) in combination with different concentrations of sodium diacetate (0.05 to 0.15%) and NaClI (0.8 to 2%) and different finished product moisture (55 to 75%) on the growth of Listeria monocytogenes in ready-to-eat meat products was evaluated using a central composite design over 18 weeks of storage at 4 degrees C. The effects of these factors on time to growth were analyzed using a time-to-failure regression method. All main effects were significant except product moisture, which was significant when included in the two- and three-way interactions (P < 0.05). Sodium benzoate was more effective (lengthening time to growth) when used with increasing concentrations of sodium diacetate and salt and decreasing finished product moisture. The model indicated that low-moisture products, e.g., bologna or wieners, could have time-to-growth values longer than 18 weeks if they were formulated with 0.1% sodium benzoate and 0.1% sodium diacetate. Time to growth in high-moisture products, e.g., ham or cured turkey breast at 75% moisture, was predicted to be much shorter for the same basic formulation (0.1% sodium benzoate and 0.1% sodium diacetate). Consequently, high-moisture ready-to-eat products in which sodium benzoate is limited to 0.1% (current standard for generally recognized as safe) may need additional ingredients to effectively inhibit growth of L. monocytogenes.
Sua-iam, Gritsada; Makul, Natt
2013-10-15
For several decades, cathode ray tubes (CRTs) were the primary display component of televisions and computers. The CRT glass envelope contains sufficient levels of lead oxide (PbO) to be considered hazardous, and there is a need for effective methods of permanently encapsulating this material during waste disposal. We examined the effect of adding limestone powder (LS) on the fresh and cured properties of self-compacting concrete (SCC) mixtures containing waste CRT glass. The SCC mixtures were prepared using Type 1 Portland cement at a constant cement content of 600 kg/m(3) and a water-to-cement ratio (w/c) of 0.38. CRT glass waste cullet was blended with river sand in proportions of 20 or 40% by weight. To suppress potential viscosity effects limestone powder was added at levels of 5, 10, or 15% by weight. The slump flow time, slump flow diameter, V-funnel flow time, Marsh cone flow time, and setting time of the fresh concrete were tested, as well as the compressive strength and ultrasonic pulse velocity of the hardened concrete. Addition of limestone powder improved the fresh and hardened properties. Pb leaching levels from the cured concrete were within US EPA allowable limits. Copyright © 2013 Elsevier Ltd. All rights reserved.
Gupta, Sanjay Prasad; Shrestha, Basanta Kumar
2018-01-01
Purpose To determine and compare the shear bond strength (SBS) of bracket-bonding system cured with light-emitting diode (LED) and halogen-based light-curing unit at various polymerization times. Materials and methods Ninety six human maxillary premolar teeth extracted for orthodontic purpose were divided into four groups, according to the light-curing unit and exposure times used. In the halogen group, the specimens were light cured for 20 and 40 seconds. In the LED group, the specimens were light cured for 5 and 10 seconds. Stainless steel brackets were bonded with Enlight bonding system, stored in distilled water at 37°C for 24 hours and then submitted to SBS testing in a universal testing machine at a crosshead speed of 0.5 mm/minute. Adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth determined by stereomicroscope at 10× magnification. Results The highest mean SBS was obtained with the halogen 40 seconds (18.27 MPa) followed by halogen 20 seconds (15.36 MPa), LED 10 seconds (14.60 MPa) and least with LED 5 seconds (12.49 MPa) group. According to analysis of variance (ANOVA) and Tukey’s multiple-comparison test, SBS of halogen 20 seconds group was not significantly different from halogen 40 seconds group, LED 5 seconds group and LED 10 seconds group, whereas halogen 40 seconds group was significantly different from LED 5 seconds and LED 10 seconds group. The method of light curing did not influence the ARI, with score 2 being predominant. Conclusion Polymerization with both halogen and LED resulted in SBS values that were clinically acceptable for orthodontic treatment in all groups. Hence, for bonding orthodontic brackets, photoactivation with halogen for 20 seconds and LED for 5 seconds is suggested. PMID:29692633
Lombardini, Marco; Chiesa, Marco; Scribante, Andrea; Colombo, Marco; Poggio, Claudio
2012-11-01
Adequate polymerization of resin composites could be considered as a crucial factor in obtaining good clinical performance, particularly in stress-bearing areas. An insufficient curing degree affects the resin composite's chemical properties The current in vitro study evaluated the influence of polymerization time and depth of cure of six commercial resin composites by Vickers microhardness (VK). SIX RESIN COMPOSITES WERE SELECTED: Three microhybrid (Esthet.X HD, Amaris, Filtek Silorane), two nanohybrid (Grandio, Ceram.X mono), and one nanofilled (Filtek Supreme XT). The VK of the surface was determined by a microhardness tester using a Vickers diamond indenter and a 200 g load applied for 15 s. The bottom to top mean VK ratio was calculated using the formula: Hardness ratio = VK of bottom surface/VK of top surface. Vickers hardness values of test materials during exposure time of 20 and 40 s and depths of cure of 2 and 3 mm were determined and compared. Data were analyzed using analysis of variance (ANOVA) test. For all the tested materials and with all the exposure time periods, hardness ratio was higher than the minimum value indicated in literature (0.8). Exposure time and depth of cure did not affect hardness ratio values for Filtek Silorane, Grandio, and Filtek Supreme XT. Among the materials tested, the nanofilled and the nanohybrid resin composites were rather insensible to thickness variations. Miicrohybrid composites, instead, had features different from one another.
Hagar, Yolanda C; Harvey, Danielle J; Beckett, Laurel A
2016-08-30
We develop a multivariate cure survival model to estimate lifetime patterns of colorectal cancer screening. Screening data cover long periods of time, with sparse observations for each person. Some events may occur before the study begins or after the study ends, so the data are both left-censored and right-censored, and some individuals are never screened (the 'cured' population). We propose a multivariate parametric cure model that can be used with left-censored and right-censored data. Our model allows for the estimation of the time to screening as well as the average number of times individuals will be screened. We calculate likelihood functions based on the observations for each subject using a distribution that accounts for within-subject correlation and estimate parameters using Markov chain Monte Carlo methods. We apply our methods to the estimation of lifetime colorectal cancer screening behavior in the SEER-Medicare data set. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Teixeira, Alfredo; Fernandes, Aline; Pereira, Etelvina; Manuel, Aristides; Rodrigues, Sandra
2017-12-01
Physicochemical and sensory characteristics of sheep and goat cured legs were evaluated. The pH values (5.7-5.8) and aw (0.87 and 0.83) found to be adequate to control meat deterioration, promoting safety and stability to shelf life of products with respect to microbial growth. The high protein (46.2 and 38.4%) and low fat (5.3 and 8.7%) percentages of the goat and sheep cured legs were the main evidence of the effect of salting and ripening processes. A low cholesterol content of 4.5% is particularly evident in sheep cured legs. Curing process produced a slight increase in the P/S ratio 0.23 and 0.17 for goat and sheep cured legs, respectively. TBARS values are much lower than the value of 2mg of MDA/Kg which is the upper limit of rancidity. Physico-chemical and sensory characteristics indicate that producing cured goat and sheep legs from cull animals can be an interesting way of adding value to animals with very low commercial prices. Copyright © 2017 Elsevier Ltd. All rights reserved.
Curing mechanism of flexible aqueous polymeric coatings.
Irfan, Muhammad; Ahmed, Abid Riaz; Kolter, Karl; Bodmeier, Roland; Dashevskiy, Andriy
2017-06-01
The objective of this study was to explain curing phenomena for pellets coated with a flexible polymeric coating based on poly(vinyl acetate) (Kollicoat® SR 30D) with regard to the effect of starter cores, thickness of drug layer, adhesion of coating to drug-layered-cores as well as coating properties. In addition, appropriate approaches to eliminate the curing effect were identified. Sugar or MCC cores were layered with the model drugs carbamazepine, theophylline, propranolol HCl, tramadol HCl and metoprolol HCl using HPMC (5 or 25% w/w, based on drug) as a binder. Drug-layered pellets were coated with Kollicoat® SR 30D in a fluidized bed coater using TEC (10% w/w) as plasticizer and talc (35-100% w/w) as anti-tacking agent. Drug release, pellet properties (morphology, water uptake-weight loss and osmolality) and adhesion of the coating to the drug layer were investigated as a function of curing at 60°C or 60°C/75% RH for 24h. The film formation of the aqueous dispersion of Kollicoat® SR 30D was complete, and therefore, a strong curing effect (decrease in drug release) at elevated temperature and humidity (60°C/75% RH) could not be explained by the well-known hydroplasticization and the further gradual coalescence of the colloidal polymer particles. According to the provided mechanistic explanation, the observed curing effect was associated with (1) high flexibility of coating, (2) adhesion between coating and drug layer, (3) water retaining properties of the drug layer, and (4) osmotically active cores. Unwanted curing effects could be minimized/eliminated by the addition of talc or/and pore-forming water soluble polymers in the coating, increasing binder amount or applying an intermediate coating, by increasing the thickness of drug layer or using non-osmotic cores. A new insight into curing phenomena mainly associated with the adhesion between drug layer and coating was provided. Appropriate approaches to avoid unwanted curing effect were identified. Copyright © 2017 Elsevier B.V. All rights reserved.
Investigations on N-nitrosopyrrolidine in dry-cured bacon.
Fiddler, W; Pensabene, J W; Gates, R A; Foster, J M; Smith, W J
1989-01-01
Dry-cured or "country-style" bacon is a low volume specialty product typically made by small producers whose production practices vary widely. These practices include the direct application of dry-cure formulations containing varying concentrations of salt, sugar, flavoring agents, sodium nitrite, and sometimes sodium nitrate, and the use of lengthy curing and processing times. Because of the possibility of generating higher levels of N-nitrosopyrrolidine (NPYR) after frying in this product type compared with pump-cured bacon, an investigation was carried out on dry-cured bacon obtained from cooperating state or federally inspected establishments. Three different samples from each of the 16 plants were analyzed. Only one sample from each of 2 different producers exceeded the Food Safety and Inspection Service (FSIS) action level of 17 ppb NPYR, indicating that the majority of samples tested were in compliance. A significant correlation (P less than 0.01) was found between residual NaNO2 prior to frying and NPYR after frying. The elimination of added nitrate in the dry-cure formulations is recommended.
Roh, Kyung-Ho; Nerem, Robert M; Roy, Krishnendu
2016-06-07
Stem cells and other functionally defined therapeutic cells (e.g., T cells) are promising to bring hope of a permanent cure for diseases and disorders that currently cannot be cured by conventional drugs or biological molecules. This paradigm shift in modern medicine of using cells as novel therapeutics can be realized only if suitable manufacturing technologies for large-scale, cost-effective, reproducible production of high-quality cells can be developed. Here we review the state of the art in therapeutic cell manufacturing, including cell purification and isolation, activation and differentiation, genetic modification, expansion, packaging, and preservation. We identify current challenges and discuss opportunities to overcome them such that cell therapies become highly effective, safe, and predictively reproducible while at the same time becoming affordable and widely available.
NASA Astrophysics Data System (ADS)
Burrell, Derek; Middlebrook, Christopher
2016-03-01
Polymer waveguides (PWGs) are used within photonic interconnects as inexpensive and versatile substitutes for traditional optical fibers. The PWGs are typically aligned to silica-based optical fibers for coupling. An epoxide elastomer is then applied and cured at the interface for index matching and rigid attachment. Self-written waveguides (SWWs) are proposed as an alternative to further reduce connection insertion loss (IL) and alleviate marginal misalignment issues. Elastomer material is deposited after the initial alignment, and SWWs are formed by injecting ultraviolet (UV) light into the fiber or waveguide. The coupled UV light cures a channel between the two differing structures. A suitable cladding layer can be applied after development. Such factors as longitudinal gap distance, UV cure time, input power level, polymer material selection and choice of solvent affect the resulting SWWs. Experimental data are compared between purely index-matched samples and those with SWWs at the fiber-PWG interface. It is shown that < 1 dB IL per connection can be achieved by either method and results indicate lowest potential losses associated with a fine-tuned self-writing process. Successfully fabricated SWWs reduce overall processing time and enable an effectively continuous low-loss rigid interconnect.
Computational methods for yeast prion curing curves.
Ridout, Martin S
2008-10-01
If the chemical guanidine hydrochloride is added to a dividing culture of yeast cells in which some of the protein Sup35p is in its prion form, the proportion of cells that carry replicating units of the prion, termed propagons, decreases gradually over time. Stochastic models to describe this process of 'curing' have been developed in earlier work. The present paper investigates the use of numerical methods of Laplace transform inversion to calculate curing curves and contrasts this with an alternative, more direct, approach that involves numerical integration. Transform inversion is found to provide a much more efficient computational approach that allows different models to be investigated with minimal programming effort. The method is used to investigate the robustness of the curing curve to changes in the assumed distribution of cell generation times. Matlab code is available for carrying out the calculations.
Botsali, Murat Selim; Kuşgöz, Adem; Altintaş, Subutay Han; Ülker, Hayriye Esra; Kiliç, Serdar; Başak, Feridun; Ülker, Mustafa
2014-01-01
The purpose of this study was first to evaluate the elution of 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) monomers from resin-modified glass ionomer cement (RMGIC) and compomers cured with halogen and light-emitting diode (LED) light-curing units (LCUs). The effect of cured materials on the viability of L929 fibroblast cells was also evaluated. One RMGIC (Ketac N100) and two compomers (Dyract Extra and Twinkystar) were tested. Materials were prepared in teflon disks and light-cured with LED or halogen LCUs. The residual monomers of resin materials in solution were identified using high-performance liquid chromatography. The fibroblast cells' viability was analyzed using MTT assay. The type of LCU did not have a significant effect on the elution of HEMA and TEGDMA. A greater amount of HEMA than TEGMDA was eluted. The amount of TEGDMA eluted from Twinkystar was greater than Dyract Extra (P < 0.05) when cured with a halogen LCU. All material-LCU combinations decreased the fibroblast cells' viability more than the control group (P < 0.01), except for Dyract Extra cured with a halogen LCU (P > 0.05). Curing with the LED LCU decreased the cells' viability more than curing with the halogen LCU for compomers. For Ketac N100, the halogen LCU decreased the cells' viability more than the LED LCU. PMID:24592149
Effect of water curing duration on strength behaviour of portland composite cement (PCC) mortar
NASA Astrophysics Data System (ADS)
Caronge, M. A.; Tjaronge, M. W.; Hamada, H.; Irmawaty, R.
2017-11-01
Cement manufacturing of Indonesia has been introduced Portland Composite Cement (PCC) to minimize the rising production cost of cement which contains 80% clinker and 20% mineral admixture. A proper curing is very important when the cement contains mineral admixture materials. This paper reports the results of an experimental study conducted to evaluate the effect of water curing duration on strength behaviour of PCC mortar. Mortar specimens with water to cement ratio of (W/C) 0.5 were casted. Compressive strength, flexural strength and concrete resistance were tested at 7, 28 and 91 days cured water. The results indicated that water curing duration is essential to continue the pozzolanic reaction in mortar which contributes to the development of strength of mortar made with PCC.
Internal curing of high performance concrete using lightweight aggregates and other techniques.
DOT National Transportation Integrated Search
2014-02-01
Internally cured concrete has been rapidly emerging over the last decade as an effective way to improve the : performance of concrete. Internal curing (IC) holds promise for producing concrete with an increased : resistance to early-age cracking and ...
The Topp-Leone generalized Rayleigh cure rate model and its application
NASA Astrophysics Data System (ADS)
Nanthaprut, Pimwarat; Bodhisuwan, Winai; Patummasut, Mena
2017-11-01
Cure rate model is one of the survival analysis when model consider a proportion of the censored data. In clinical trials, the data represent time to recurrence of event or death of patients are used to improve the efficiency of treatments. Each dataset can be separated into two groups: censored and uncensored data. In this work, the new mixture cure rate model is introduced based on the Topp-Leone generalized Rayleigh distribution. The Bayesian approach is employed to estimate its parameters. In addition, a breast cancer dataset is analyzed for model illustration purpose. According to the deviance information criterion, the Topp-Leone generalized Rayleigh cure rate model shows better result than the Weibull and exponential cure rate models.
Post-cure heat treatments for composites: properties and fractography.
Ferracane, J L; Condon, J R
1992-09-01
Two commercial and four experimental composites were subjected to post-cure heat treatments of 10 min and 3 h duration immediately after light-curing. Fracture toughness, flexural modulus, microhardness and degree of conversion (FTIR) were evaluated 24 h later. The results showed that post-cure heat treatments at 120 degrees C of short or long duration can be used to produce significant improvements in the degree of cure and the mechanical properties of dental composites used as inlays. A 10 min heat treatment was as effective as a 3 h treatment in enhancing properties and degree of cure. In addition, a 3 h heat treatment carried out 7 days after the initial light-curing was capable of improving properties and cure to almost the same extent as the immediate heat treatments. The improvement in properties, in conjunction with the fractography, indicate a toughening of the filled resin matrix and possibly an improved filler/matrix adhesion in the microfills. The changes appear to be predominantly the result of an increase in degree of cure.
Martínez-Sánchez, Sara María; Minguela, Alfredo; Prieto-Merino, David; Zafrilla-Rentero, María Pilar; Abellán-Alemán, José; Montoro-García, Silvia
2017-01-01
Background and aims: Dietary studies have shown that active biopeptides provide protective health benefits, although the mediating pathways are somewhat uncertain. To throw light on this situation, we studied the effects of consuming Spanish dry-cured ham on platelet function, monocyte activation markers and the inflammatory status of healthy humans with pre-hypertension. Methods: Thirty-eight healthy volunteers with systolic blood pressure of >125 mmHg were enrolled in a two-arm crossover randomized controlled trial. Participants received 80 g/day dry-cured pork ham of >11 months proteolysis or 100 g/day cooked ham (control product) for 4 weeks followed by a 2-week washout before “crossing over” to the other treatment for 4 more weeks. Soluble markers and cytokines were analyzed by ELISA. Platelet function was assessed by measuring P-selectin expression and PAC-1 binding after ADP (adenosine diphosphate) stimulation using whole blood flow cytometry. Monocyte markers of the pathological status (adhesion, inflammatory and scavenging receptors) were also measured by flow cytometry in the three monocyte subsets after the interventional period. Results: The mean differences between dry-cured ham and cooked ham followed by a time period adjustment for plasmatic P-selectin and interleukin 6 proteins slightly failed (p = 0.062 and p = 0.049, respectively), notably increased for MCP-1 levels (p = 0.023) while VCAM-1 was not affected. Platelet function also decreased after ADP stimulation. The expression of adhesion and scavenging markers (ICAM1R, CXCR4 and TLR4) in the three subsets of monocytes was significantly higher (all p < 0.05). Conclusions: The regular consumption of biopeptides contained in the dry-cured ham but absent in cooked ham impaired platelet and monocyte activation and the levels of plasmatic P-selectin, MCP-1 and interleukin 6 in healthy subjects. This study strongly suggests the existence of a mechanism that links dietary biopeptides and beneficial health effects. PMID:28333093
Time dependence of composite shrinkage using halogen and LED light curing.
Uhl, Alexander; Mills, Robin W; Rzanny, Angelika E; Jandt, Klaus D
2005-03-01
The polymerization shrinkage of light cured dental composites presents the major drawback for these aesthetically adaptable restorative materials. LED based light curing technology has recently become commercially available. Therefore, the aim of the present study was to investigate if there was a statistically significant difference in linear and volumetric composite shrinkage strain if a LED LCU is used for the light curing process rather than a conventional halogen LCU. The volumetric shrinkage strain was determined using the Archimedes buoyancy principle after 5, 10, 20, 40 s of light curing and after 120 s following the 40 s light curing time period. The linear shrinkage strain was determined with a dynamic mechanical analyzer for the composites Z100, Spectrum, Solitaire2 and Definite polymerized with the LCUs Trilight (halogen), Freelight I (LED) and LED63 (LED LCU prototype). The changes in irradiance and spectra of the LCUs were measured after 0, 312 and 360 min of duty time. In general there was no considerable difference in shrinkage of the composites Z100, Spectrum or Solitaire2 when the LED63 was used instead of the Trilight. There was, however, a statistically significant difference in shrinkage strain when the composite Definite was polymerized with the LED63 instead of the Trilight. The spectrum of the Trilight changed during the experiment considerably whereas the LED63 showed an almost constant light output. The Freelight I dropped considerably in irradiance and had to be withdrawn from the study because of technical problems. The composites containing only the photoinitiator camphorquinone showed similar shrinkage strain behaviour when a LED or halogen LCU is used for the polymerization. The irradiance of some LED LCUs can also decrease over time and should therefore be checked on a regular basis.
Liu, Lu-Wen; Zeng, Wei-Li; Zhu, Xiang-Fei; Wu, Jin-Quan; Lin, Zhao-Xiang
2014-03-01
In the present paper, the time evolution study on slip soils treated by different proportions of ionic soil stabilizer (ISS) water solution was conducted by the LIBS system and the relationship between the cation exchange and such engineering properties of reinforcing soil as plasticity index, cohesive force and coefficient of compressibility were analyzed. The results showed that the cation exchange velocity of the proportion of 1:200 ISS reinforcing soil is the fastest among the three proportions (1:100, 1:200 and 1:300) and the modification effect of engineering performance index is quite obvious. These studies provide an experimental basis for the ISS applied to curing project, and monitoring geotechnical engineering performance by LIBS technology also provides a new way of thinking for the curing project monitoring.
Chemoviscosity modeling for thermosetting resins, 2
NASA Technical Reports Server (NTRS)
Hou, T. H.
1985-01-01
A new analytical model for simulating chemoviscosity of thermosetting resin was formulated. The model is developed by modifying the Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By assuming a linear relationship between the glass transition temperature and the degree of cure of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature dependent functions of the modified WLF theory constants were determined from the isothermal cure data of Lee, Loos, and Springer for the Hercules 3501-6 resin system. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data reported by Carpenter. A chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformations of the thermosetting resin systems during cure was established.
Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements.
Ilie, Nicoleta; Simon, Alexander
2012-04-01
Light supplying to luting resin cements is impeded in several clinical situations, causing us to question whether materials can properly be cured to achieve adequately (or adequate) mechanical properties. The aim of this study was therefore to analyse the effect of light on the micro-mechanical properties of eight popular dual-cured self-adhesive resin cements by comparing them with two conventional, also dual-cured, resin cements. Four different curing procedures were applied: auto-polymerisation (dark curing) and light curing (LED unit, Freelight 2, 20 s) by applying the unit directly on the samples' surface, at a distance of 5 and 10 mm. Twenty minutes after curing, the samples were stored for 1 week at 37°C in a water-saturated atmosphere. The micro-mechanical properties-Vickers hardness, modulus of elasticity, creep and elastic/plastic deformation-were measured. Data were analysed with multivariate ANOVA followed by Tukey's test and partial eta-squared statistics (p < 0.05). A very strong influence of the material as well as filler volume and weight on the micro-mechanical properties was measured, whereas the influence of the curing procedure and type of cement-conventional or self-adhesive-was generally low. The influence of light on the polymerisation process was material dependent, with four different behaviour patterns to be distinguished. As a material category, significantly higher micro-mechanical properties were measured for the conventional compared to the self-adhesive resin cements, although this difference was low. Within the self-adhesive resin cements group, the variation in micro-mechanical properties was high. The selection of suitable resin cements should be done by considering, besides its adhesive properties, its micro-mechanical properties and curing behaviour also.
Cui, Xu; Zhao, Cunju; Gu, Yifei; Li, Le; Wang, Hui; Huang, Wenhai; Zhou, Nai; Wang, Deping; Zhu, Yi; Xu, Jun; Luo, Shihua; Zhang, Changqing; Rahaman, Mohamed N
2014-03-01
Osteomyelitis (bone infection) is often difficult to cure. The commonly-used treatment of surgical debridement to remove the infected bone combined with prolonged systemic and local antibiotic treatment has limitations. In the present study, an injectable borate bioactive glass cement was developed as a carrier for the antibiotic vancomycin, characterized in vitro, and evaluated for its capacity to cure osteomyelitis in a rabbit tibial model. The cement (initial setting time = 5.8 ± 0.6 min; compressive strength = 25.6 ± 0.3 MPa) released vancomycin over ~25 days in phosphate-buffered saline, during which time the borate glass converted to hydroxyapatite (HA). When implanted in rabbit tibial defects infected with methicillin-resistant Staphylococcus aureus (MRSA)-induced osteomyelitis, the vancomycin-loaded cement converted to HA and supported new bone formation in the defects within 8 weeks. Osteomyelitis was cured in 87 % of the defects implanted with the vancomycin-loaded borate glass cement, compared to 71 % for the defects implanted with vancomycin-loaded calcium sulfate cement. The injectable borate bioactive glass cement developed in this study is a promising treatment for curing osteomyelitis and for regenerating bone in the defects following cure of the infection.
Steam Cured Self-Consolidating Concrete and the Effects of Limestone Filler
NASA Astrophysics Data System (ADS)
Aqel, Mohammad A.
The purpose of this thesis is to determine the effect and the mechanisms associated with replacing 15% of the cement by limestone filler on the mechanical properties and durability performance of self-consolidating concrete designed and cured for precast/prestressed applications. This study investigates the role of limestone filler on the hydration kinetics, mechanical properties (12 hours to 300 days), microstructural and durability performance (rapid chloride permeability, linear shrinkage, sulfate resistance, freeze-thaw resistance and salt scaling resistance) of various self-consolidating concrete mix designs containing 5% silica fume and steam cured at a maximum holding temperature of 55°C. This research also examines the resistance to delayed ettringite formation when the concrete is steam cured at 70°C and 82°C and its secondary consequences on the freeze-thaw resistance. The effect of several experimental variables related to the concrete mix design and also the curing conditions are examined, namely: limestone filler fineness, limestone filler content, cement type, steam curing duration and steam curing temperature. In general, the results reveal that self-consolidating concrete containing 15% limestone filler, steam cured at 55°C, 70°C and 82°C, exhibited similar or superior mechanical and transport properties as well as long term durability performance compared to similar concrete without limestone filler. When the concrete is steam cured at 55°C, the chemical reactivity of limestone filler has an important role in enhancing the mechanical properties at 16 hours (compared to the concrete without limestone filler) and compensating for the dilution effect at 28 days. Although, at 300 days, the expansion of all concrete mixes are below 0.05%, the corresponding freeze-thaw durability factors vary widely and are controlled by the steam curing temperature and the chemical composition of the cement. Overall, the material properties indicate that the use of 15% limestone filler as cement replacement is a viable option for the precast/prestressed concrete applications, and in addition, would also have economic and environmental benefits.
Comparative static curing versus dynamic curing on tablet coating structures.
Gendre, Claire; Genty, Muriel; Fayard, Barbara; Tfayli, Ali; Boiret, Mathieu; Lecoq, Olivier; Baron, Michel; Chaminade, Pierre; Péan, Jean Manuel
2013-09-10
Curing is generally required to stabilize film coating from aqueous polymer dispersion. This post-coating drying step is traditionally carried out in static conditions, requiring the transfer of solid dosage forms to an oven. But, curing operation performed directly inside the coating equipment stands for an attractive industrial application. Recently, the use of various advanced physico-chemical characterization techniques i.e., X-ray micro-computed tomography, vibrational spectroscopies (near infrared and Raman) and X-ray microdiffraction, allowed new insights into the film-coating structures of dynamically cured tablets. Dynamic curing end-point was efficiently determined after 4h. The aim of the present work was to elucidate the influence of curing conditions on film-coating structures. Results demonstrated that 24h of static curing and 4h of dynamic curing, both performed at 60°C and ambient relative humidity, led to similar coating layers in terms of drug release properties, porosity, water content, structural rearrangement of polymer chains and crystalline distribution. Furthermore, X-ray microdiffraction measurements pointed out different crystalline coating compositions depending on sample storage time. An aging mechanism might have occur during storage, resulting in the crystallization and the upward migration of cetyl alcohol, coupled to the downward migration of crystalline sodium lauryl sulfate within the coating layer. Interestingly, this new study clearly provided further knowledge into film-coating structures after a curing step and confirmed that curing operation could be performed in dynamic conditions. Copyright © 2013 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kropka, Jamie Michael; Stavig, Mark E.; Jaramillo, Rex
When thermosetting polymers are used to bond or encapsulate electrical, mechanical or optical assemblies, residual stress, which often affects the performance and/or reliability of these devices, develops within the structure. The Thin-Disk-on-Cylinder structural response test is demonstrated as a powerful tool to design epoxy encapsulant cure schedules to reduce residual stress, even when all the details of the material evolution during cure are not explicitly known. The test's ability to (1) distinguish between cohesive and adhesive failure modes and (2) demonstrate methodologies to eliminate failure and reduce residual stress, make choices of cure schedules that optimize stress in the encapsulantmore » unambiguous. For the 828/DEA/GMB material in the Thin-Disk-on-Cylinder geometry, the stress associated with cure is significant and outweighs that associated with cool down from the final cure temperature to room temperature (for measured lid strain, Scure I > I I e+h erma * II) * The difference between the final cure temperature and 1 1 -- the temperature at which the material gels, Tf-T ge i, was demonstrated to be a primary factor in determining the residual stress associated with cure. Increasing T f -T ge i leads to a reduction in cure stress that is described as being associated with balancing some of the 828/DEA/GMB cure shrinkage with thermal expansion. The ability to tune residual stress associated with cure by controlling T f -T ge i would be anticipated to translate to other thermosetting encapsulation materials, but the times and temperatures appropriate for a given material may vary widely.« less
Cytotoxicity of four categories of dental cements.
Schmid-Schwap, Martina; Franz, Alexander; König, Franz; Bristela, Margit; Lucas, Trevor; Piehslinger, Eva; Watts, David C; Schedle, Andreas
2009-03-01
Assessment of dental material biocompatibility is gaining increasing importance for both patients and dentists. Dental cements may be in contact with oral soft tissues for prolonged periods of time and play an important role in prosthetic rehabilitation. The aim of the present study was to evaluate eight dental cements using a standardized L929-fibroblast cell culture test. For each material, fresh specimens (added to the cultures immediately after preparation) and specimens preincubated for 7 days in cell culture medium were prepared according to the manufacturers' recommendations. After exposure to test specimens, cell numbers were compared to glass controls. The main outcome was a two-sided 95% confidence interval for the mean value of the standardized cell number for each substance investigated. Fresh specimens of all tested cements showed significant cytotoxicity, which diminished after 7 days preincubation. Cytotoxicity of fresh adhesive and self-adhesive resin cements was lower when specimens were dual-cured compared to self-cured. A rank order of cytotoxicity was established based on mean values: Nexus 2 (dual-cured) showed least cytotoxicity, followed by Variolink II (dual-cured), Nexus 2 (self-cured), Harvard, RelyxUnicem (dual-cured), Panavia 21, Fujicem, Durelon, Variolink II (self-cured), RelyxUnicem (self-cured), Maxcem (dual-cured) and Maxcem (self-cured). When bondings were added to Nexus 2 or Variolink II specimens, a slight increase in cytotoxicity was observed. Adhesive resin cements showed less cytotoxicity than self-adhesive and chemically setting cements. Bonding only slightly influenced cytotoxicity of the adhesive resin cements. Dual-cured specimens of adhesive and self-adhesive resin cements showed significantly less toxicity than self-cured specimens.
Robach, M C
1979-01-01
The effects of the initial pH and a "short pump" on the outgrowth of Clostridium sporogenes PA 3679 spores in comminuted cured pork were studied. Fresh ground pork was cured with salt, sugar, phosphate, ascorbate, and varying amounts of sodium nitrite and sorbic acid. The product was comminuted and inoculated with 1,000 spores of C. sporogenes per g. The meat was stuffed into 1-ounce (ca. 28.4-g) aluminum tubes, cooked to 58.5 degrees C, cooled, and incubated at 27 degrees C to observe for swells. Product cured with 0.2% sorbic acid in combination with 40 ppm sodium nitrite (40 microgram/g) had better clostridium inhibition than did product cured with 120 ppm nitrite within a pH range of 5.0 to 6.7. The sorbic acid-40 ppm nitrite combination also gave better clostridial protection than did the 120 ppm nitrite alone when reduced amounts of curing ingredients were present. PMID:44445
Robach, M C
1979-11-01
The effects of the initial pH and a "short pump" on the outgrowth of Clostridium sporogenes PA 3679 spores in comminuted cured pork were studied. Fresh ground pork was cured with salt, sugar, phosphate, ascorbate, and varying amounts of sodium nitrite and sorbic acid. The product was comminuted and inoculated with 1,000 spores of C. sporogenes per g. The meat was stuffed into 1-ounce (ca. 28.4-g) aluminum tubes, cooked to 58.5 degrees C, cooled, and incubated at 27 degrees C to observe for swells. Product cured with 0.2% sorbic acid in combination with 40 ppm sodium nitrite (40 microgram/g) had better clostridium inhibition than did product cured with 120 ppm nitrite within a pH range of 5.0 to 6.7. The sorbic acid-40 ppm nitrite combination also gave better clostridial protection than did the 120 ppm nitrite alone when reduced amounts of curing ingredients were present.
NASA Astrophysics Data System (ADS)
Arel, Hasan Şahan
The effects of silica fume fineness and fiber aspect ratio on the compressive strength and impact resistance of ultra high-performance fiber-reinforced concrete (UHPFRC) are investigated experimentally. To this end, UHPFRC mixtures are manufactured by combining silica fumes with different fineness (specific surface areas: 17,200, 20,000, and 27,600 m2/kg) and hooked-end steel fibers with various aspect ratios (lengths: 8, 13, and 16 mm). The samples are subjected to standard curing, steam curing, and hot-water curing. Compressive strength tests are conducted after 7-, 28-, 56-, and 90-day curing periods, and an impact resistance experiment is performed after the 90th day. A steam-cured mixture of silica fumes with a specific surface area of 27,600 m2/kg and 16-mm-long fibers produce better results than the other mixtures in terms of mechanical properties. Moreover, impact resistance increases with the fiber aspect ratio.
Wang, Yuan-Yuan; Liu, Xiao-Ying
2014-01-01
To observe clinical therapeutic effect of fuzhong (supporting the middle-jiao) manipulation of tuina for infantile anorexia. Eighty-one children with anorexia were treated with fuzhong manipulation, including abdominal kneading, acupressure at Zhongwan (CV 12), Lanmen (Extra), Tianshu (ST 25), Zusanli (ST 36), Sanyinjiao (SP 6), spine pinching, warm moxibustion and warm scraping with supporting-yang cupping, three times a week, six times as a session. Onset time, therapeutic effect and TCM symptom scores before and after treatment were observed after two sessions and differences of therapeutic effect among different patterns were compared. Seventy-two children had the effect in one session while 41 children had the effect within half of a session. 38 cases were clinically cured, 15 cases were markedly effective, 23 cases were effective and 5 cases were failed. The total effective rate was 93.8%. Compared with before treatment, TCM symptom scores, including appetite, food intake, complexion and defecation, were all obviously improved after treatment (all P < 0.001). The clinical cured rate was 45.2% (19/42) in the pattern of dysfunction of spleen in transportation, 45.8% (11/24) in the pattern of qi deficiency of spleen and stomach, 50.0% (4/8) in the pattern of yin deficiency of spleen and stomach, 57.1% (4/7) in the pattern of liver sufficiency and spleen insufficiency, which had no obvious differences among different patterns (all P > 0.05). The fuzhong manipulation of tuina has quick onset time and satisfied clinical therapeutic effect, which could obviously improve symptoms and is fit for different patterns of infantile anorexia.
Cure models for estimating hospital-based breast cancer survival.
Rama, Ranganathan; Swaminathan, Rajaraman; Venkatesan, Perumal
2010-01-01
Research on cancer survival is enriched by development and application of innovative analytical approaches in relation to standard methods. The aim of the present paper is to document the utility of a mixture model to estimate the cure fraction and compare it with other approaches. The data were for 1,107 patients with locally advanced breast cancer, who completed the neo-adjuvant treatment protocol during 1990-99 at the Cancer Institute (WIA), Chennai, India. Tumour stage, post-operative pathological node (PN) and tumour residue (TR) status were studied. Event free survival probability was estimated using the Kaplan-Meier method. Cure models under proportional and non-proportional hazard assumptions following log normal distribution for survival time were used to estimate both the cure fraction and the survival function for the uncured. Event free survival at 5 and 10 years were 64.2% and 52.6% respectively and cure fraction was 47.5% for all cases together. Follow up ranged between 0-15 years and survival probabilities showed minimal changes after 7 years of follow up. TR and PN emerged as independent prognostic factors using Cox and proportional hazard (PH) cure models. Proportionality condition was violated when tumour stage was considered and it was statistically significant only under PH and not under non PH cure models. However, TR and PN continued to be independent prognostic factors after adjusting for tumour stage using the non PH cure model. A consistent ordering of cure fractions with respect to factors of PN and TR was forthcoming across tumour stages using PH and non PH cure models, but perceptible differences in survival were observed between the two. If PH conditions are violated, analysis using a non PH model is advocated and mixture cure models are useful in estimating the cure fraction and constructing survival curves for non-cures.
Use of the Word "Cure" in the Oncology Literature.
Prasad, Vinay
2015-08-01
"Cure" is an important word in oncology but its use in the published literature has not been examined. I investigated all oncology articles using cure in the title field and published in 2012. The definition of cure was examined, specifically whether or not authors use the word to connote some surviving subset of patients who go on to experience outcomes similar to age-matched, normal controls-a definition favored by researchers and employed in survival function analyses. All articles published between January 1, 2012, and December 31, 2012, with the word cure in the title field were retrieved from Thompson Reuters' Web of Science. After exclusions, articles were read in full to examine what definitions of cure was used. Additionally, for each situation (type of cancer, stage/grade) where the word cure was used, a literature search was performed to ascertain whether there existed documented cases of cure. Twenty-nine oncology articles used the word cure in their title in 2012. Nearly half, 14 (48%) of 29, used the term in situations (cancer type, stage/grade) currently considered incurable. Approximately one-third (34.5%) of the articles used the word consistent with the definition that, after a set period of time, some surviving subset of patients experience survival similar to normal controls. There is heterogeneity in the use of the word cure in the literature. © The Author(s) 2014.
[Treatment of chronic bovine endometritis and factors for treatment success].
Feldmann, M; Tenhagen genannt Emming, S; Hoedemaker, M
2005-01-01
In a controlled field trial, 178 dairy cows with chronic endometritis and at least 21 days in lactation were randomly assigned to four different treatment groups: prostaglandin F2alpha intramuscularly (PG, 5 mg dinoprost (5 ml Dinolytic), n = 51), intrauterine antibiotics (AB; 400 mg ampicillin + 800 oxacillin (20 ml Totocillin), n = 49), intrauterine antiseptics (AS; 100 ml 4% Lotagen, n = 50); control (C, no initial treatment, n = 28). Before treatment, uterine swabs for bacteriologic examination and blood samples for determination of serum progesterone concentrations were collected. Two weeks following the first treatment, cows were reexamined. In case no clinical cure was diagnosed, treatment was repeated and control cows were treated for the first time with one of the three treatments mentioned above. The four treatment groups did not differ with respect to the clinical cure or reproductive performance. Therefore, factors that might have an influence on clinical cure and fertility were evaluated. With increasing duration of lactation, the clinical cure after a single treatment increased significantly over all treatment groups from 59.5% (treatment before day 42 postpartum) to 79.6% (treatment following day 42 postpartum) (P < 0.05). Within the PG group, a statistically significantly higher cure rate after a single treatment and first service conception rate and a lower pregnancy index were obtained when the treatment was performed following day 42 postpartum (P < 0.05). This was not the case in the other treatment groups. A retarded involution of the uterus based on the size had a negative effect on clinical cure over all groups (first treatment clinical cure: 68.2% (small uteri) vs 44.4% (large uteri); P < 0.05). Within groups, this effect was also detected, but only as a trend (P > 0.05). Isolation of Arcanobacterium (A.) pyogenes negatively influenced first treatment clinical cure over all treatment groups (79.0% vs 31.5%) and within treatment groups (P < 0.05). In the AB group, the pregnancy index, days open and the interval from first insemination to conception increased compared with the other treatment groups, when A. pyogenes was detected. Isolation of unspecific bacteria and the presence or absence of a corpus luteum only had minor effects over all and within the PG, AS and C group. Within the AB group, presence of luteal tissue was connected with a higher pregnancy index and increased days open and interval from first insemination to conception (P < 0.05). A multivariate analysis revealed that the presence of A. pyogenes and no initial treatment (control group) had a statistically significant independent and negative influence on the first treatment clinical cure. Ill-smelling vaginal discharge and no treatment had a negative independent effect on first service conception rate. Furthermore, days open were negatively influenced by the interval from calving to first examination and the presence of ill-smelling vaginal discharge. In conclusion, under the conditions of this field study, it seems preferrable to treat chronic endometritis. However, under the condition of a herd health program with continuous observation of sick and healthy animals, a wait-and-see attitude might also be justified.
Smith, Lesley; Glaser, Adam W; Kinsey, Sally E; Greenwood, Darren C; Chilton, Lucy; Moorman, Anthony V; Feltbower, Richard G
2018-05-29
'Cure models' offer additional information to traditional epidemiological approaches to assess survival for cancer patients by simultaneously estimating the proportion cured and the survival of those 'uncured'. The proportion cured is a summary of long-term survival while the median survival time of the uncured provides important information on those who are not long-term survivors. Population-based trends in the cure proportion and survival of the uncured for childhood acute lymphoblastic leukaemia (ALL) by clinical prognostic risk factors were estimated using flexible parametric cure models, based on overall survival and event-free survival. Children aged 1-17 years diagnosed between 1990 and 2011 in Yorkshire, UK, were included (n = 492). The percentage cured increased from 77% (95% confidence interval 70-84%) in 1990-1997 to 89% (84-93%) in 2003-2011, while the median survival time of the uncured decreased from 3·2 years (2·2-4·1 years) to 0·7 years (0-1·5 years). Models based on event-free survival showed a similar trend. The 5-year cumulative incidence of relapse substantially decreased from 35% in 1990-97 to 9% in 2003-2011. These results show selective improvement in survival between 1990 and 2011 with a significant reduction in the risk of relapse alongside a reduced absolute duration of survival for those destined to be uncured. © 2018 John Wiley & Sons Ltd.
Merino, Leonardo; Darnerud, Per Ola; Toldrá, Fidel; Ilbäck, Nils-Gunnar
2016-01-01
The food additive nitrite (E249, E250) is commonly used in meat curing as a food preservation method. Because of potential negative health effects of nitrite, its use is strictly regulated. In an earlier study we have shown that the calculated intake of nitrite in children can exceed the acceptable daily intake (ADI) when conversion from dietary nitrate to nitrite is included. This study examined time-dependent changes in nitrite levels in four Swedish meat products frequently eaten by children: pork/beef sausage, liver paté and two types of chicken sausage, and how the production process, storage and also boiling (e.g., simmering in salted water) and frying affect the initial added nitrite level. The results showed a steep decrease in nitrite level between the point of addition to the product and the first sampling of the product 24 h later. After this time, residual nitrite levels continued to decrease, but much more slowly, until the recommended use-by date. Interestingly, this continuing decrease in nitrite was much smaller in the chicken products than in the pork/beef products. In a pilot study on pork/beef sausage, we found no effects of boiling on residual nitrite levels, but frying decreased nitrite levels by 50%. In scenarios of time-dependent depletion of nitrite using the data obtained for sausages to represent all cured meat products and including conversion from dietary nitrate, calculated nitrite intake in 4-year-old children generally exceeded the ADI. Moreover, the actual intake of nitrite from cured meat is dependent on the type of meat source, with a higher residual nitrite levels in chicken products compared with pork/beef products. This may result in increased nitrite exposure among consumers shifting their consumption pattern of processed meats from red to white meat products.
Merino, Leonardo; Darnerud, Per Ola; Toldrá, Fidel; Ilbäck, Nils-Gunnar
2016-01-01
ABSTRACT The food additive nitrite (E249, E250) is commonly used in meat curing as a food preservation method. Because of potential negative health effects of nitrite, its use is strictly regulated. In an earlier study we have shown that the calculated intake of nitrite in children can exceed the acceptable daily intake (ADI) when conversion from dietary nitrate to nitrite is included. This study examined time-dependent changes in nitrite levels in four Swedish meat products frequently eaten by children: pork/beef sausage, liver paté and two types of chicken sausage, and how the production process, storage and also boiling (e.g., simmering in salted water) and frying affect the initial added nitrite level. The results showed a steep decrease in nitrite level between the point of addition to the product and the first sampling of the product 24 h later. After this time, residual nitrite levels continued to decrease, but much more slowly, until the recommended use-by date. Interestingly, this continuing decrease in nitrite was much smaller in the chicken products than in the pork/beef products. In a pilot study on pork/beef sausage, we found no effects of boiling on residual nitrite levels, but frying decreased nitrite levels by 50%. In scenarios of time-dependent depletion of nitrite using the data obtained for sausages to represent all cured meat products and including conversion from dietary nitrate, calculated nitrite intake in 4-year-old children generally exceeded the ADI. Moreover, the actual intake of nitrite from cured meat is dependent on the type of meat source, with a higher residual nitrite levels in chicken products compared with pork/beef products. This may result in increased nitrite exposure among consumers shifting their consumption pattern of processed meats from red to white meat products. PMID:26743589
Ito, Yuri; Nakayama, Tomio; Miyashiro, Isao; Sugimoto, Tomoyuki; Ioka, Akiko; Tsukuma, Hideaki; Abdel-Rahman, Manar E; Rachet, Bernard
2012-10-01
Since the 1960s, Japan has experienced a striking increase in the incidence of colorectal cancer, now the second most common cancer in the country. Meanwhile, the management of colorectal cancer has changed dramatically with the implementation of, for example, screening, endoscopy and adjuvant chemotherapy. It is therefore of interest to monitor the long-term trends in population 'cure' in Japan. We analysed 33 885 colorectal cancer cases diagnosed between 1975 and 2000 in Osaka. We applied the multivariable mixture cure model to estimate cure fraction and median survival time (MST) for 'uncured' patients, by sex, age, stage, period at diagnosis and subsite. For colon cancer, the cure fraction increased by about 25%, while MST for the uncured was prolonged from 8 to 12 months. The cure fraction was 5% higher in men than in women, while MST was similar in both. The cure fraction also increased for localized and regional tumours. For rectal cancer, the cure fraction increased by about 25-30%, but remained lower than for colon cancer. From the late 1970s, the cure fraction for colorectal cancer increased dramatically due to better management of detection and care for colorectal cancer. This improvement was obtained at the cost of shorter MST for uncured patients.
Cost-effectiveness of community health workers in tuberculosis control in Bangladesh.
Islam, Md Akramul; Wakai, Susumu; Ishikawa, Nobukatsu; Chowdhury, A. M. R.; Vaughan, J. Patrick
2002-01-01
OBJECTIVE: To compare the cost-effectiveness of the tuberculosis (TB) programme run by the Bangladesh Rural Advancement Committee (BRAC), which uses community health workers (CHWs), with that of the government TB programme which does not use CHWs. METHODS: TB control statistics and cost data for July 1996 - June 1997 were collected from both government and BRAC thanas (subdistricts) in rural Bangladesh. To measure the cost per patient cured, total costs were divided by the total number of patients cured. FINDINGS: In the BRAC and government areas, respectively, a total of 186 and 185 TB patients were identified over one year, with cure rates among sputum-positive patients of 84% and 82%. However, the cost per patient cured was US$ 64 in the BRAC area compared to US$ 96 in the government area. CONCLUSION: The government programme was 50% more expensive for similar outcomes. Although both the BRAC and government TB control programmes appeared to achieve satisfactory cure rates using DOTS (a five-point strategy), the involvement of CHWs was found to be more cost-effective in rural Bangladesh. With the same budget, the BRAC programme could cure three TB patients for every two in the government programme. PMID:12132000
Intelligent sensor-model automated control of PMR-15 autoclave processing
NASA Technical Reports Server (NTRS)
Hart, S.; Kranbuehl, D.; Loos, A.; Hinds, B.; Koury, J.
1992-01-01
An intelligent sensor model system has been built and used for automated control of the PMR-15 cure process in the autoclave. The system uses frequency-dependent FM sensing (FDEMS), the Loos processing model, and the Air Force QPAL intelligent software shell. The Loos model is used to predict and optimize the cure process including the time-temperature dependence of the extent of reaction, flow, and part consolidation. The FDEMS sensing system in turn monitors, in situ, the removal of solvent, changes in the viscosity, reaction advancement and cure completion in the mold continuously throughout the processing cycle. The sensor information is compared with the optimum processing conditions from the model. The QPAL composite cure control system allows comparison of the sensor monitoring with the model predictions to be broken down into a series of discrete steps and provides a language for making decisions on what to do next regarding time-temperature and pressure.
Self-Healing Nanotextured Vascular-like Materials: Mode I Crack Propagation.
Lee, Min Wook; Sett, Soumyadip; An, Seongpil; Yoon, Sam S; Yarin, Alexander L
2017-08-16
Here, we investigate crack propagation initiated from an initial notch in a self-healing material. The crack propagation in the core-shell nanofiber mats formed by coelectrospinning and the composites reinforced by them is in focus. All samples are observed from the crack initiation until complete failure. Due to the short-time experiments done on purpose, the resin and cure released from the cores of the core-shell nanofibers could not achieve a complete curing and stop crack growth, especially given the fact that no heating was used. The aim is to elucidate their effect on the rate of crack propagation. The crack propagation speed in polyacrylonitrile (PAN)-resin-cure nanofiber mats (with PAN being the polymer in the shell) was remarkably lower than that in the corresponding monolithic PAN nanofiber mat, down to 10%. The nanofiber mats were also encased in polydimethylsiloxane (PDMS) matrix to form composites. The crack shape and propagation in the composite samples were studied experimentally and analyzed theoretically, and the theoretical results revealed agreement with the experimental data.
Kanie, Takahito; Kadokawa, Akihiko; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji
2008-11-01
We investigated the viscosity and mechanical properties of experimental light-curing soft lining materials based on six commercially available urethane (meth)acrylate oligomers. The viscosities of the six oligomers were 1.9, 20.6, 26.8, 144.0, 185.3, and 8803.4 Pa*s at 25 degrees C. Two monomers (ethyl- and butyl-methacrylate) were added at 20 wt% to these oligomers to decrease the viscosity, resulting in viscosity reductions of 0.2 to 13.6 Pa*s for the six oligomers. The mechanical properties (compressive modulus, Shore A hardness, and tensile strength) were measured after two times light-polymerization for 3 min. The addition of the monomers to the oligomers only slightly changed the mechanical properties, in contrast to the large viscosity changes. Based on these results, it appears that the addition of ethyl- or butyl-methacrylate monomers is useful for decreasing the viscosity of experimental light-curing soft lining materials without changing their mechanical properties.
NASA Astrophysics Data System (ADS)
Tavakoli, Mahmoud; Rocha, Rui; Osorio, Luis; Almeida, Miguel; de Almeida, Anibal; Ramachandran, Vivek; Tabatabai, Arya; Lu, Tong; Majidi, Carmel
2017-03-01
Carbon doped PDMS (cPDMS), has been used as a conductive polymer for stretchable electronics. Compared to liquid metals, cPDMS is low cost and is easier to process or to print with an additive manufacturing process. However, changes on the conductance of the carbon based conductive PDMS (cPDMS) were observed over time, in particular after integration of cPDMS and the insulating polymer. In this article we investigate the process parameters that lead to improved stability over conductance of the cPDMS over time. Slight modifications to the fabrication process parameters were conducted and changes on the conductance of the samples for each method were monitored. Results suggested that change of the conductance happens mostly after integration of a pre-polymer over a cured cPDMS, and not after integration of the cPDMS over a cured insulating polymer. We show that such changes can be eliminated by adjusting the integration priority between the conductive and insulating polymers, by selecting the right curing temperature, changing the concentration of the carbon particles and the thickness of the conductive traces, and when possible by changing the insulating polymer material. In this way, we obtained important conclusions regarding the effect of these parameters on the change of the conductance over time, that should be considered for additive manufacturing of soft electronics. Also, we show that these changes can be possibly due to the diffusion from PDMS into cPDMS.
Shimamoto, Daisuke; Hotta, Yuji
2018-01-01
The interfacial adhesion of recycled carbon fiber (CF) reinforced epoxy composite heated by microwave (MW) irradiation were investigated by changing the curing state of the epoxy resin. The recycled CF was recovered from the composite, which was prepared by vacuum-assisted resin transfer molding, by thermal degradation at 500 or 600 °C. Thermogravimetric analysis showed that the heating at 600 °C caused rough damage to the CF surface, whereas recycled CF recovered at 500 °C have few defects. The interfacial shear strength (IFSS) between recycled CF and epoxy resin was measured by a single-fiber fragmentation test. The test specimen was heated by MW after mixing the epoxy resin with a curing agent or pre-curing, in order to investigate the curing effects on the matrix resin. The IFSSs of the MW-irradiated samples were significantly varied by the curing state of the epoxy resin and the surface condition of recycled CF, resulting that they were 99.5 to 131.7% of oven heated samples Furthermore, rheological measurements showed that the viscosity and shrinking behaviors of epoxy resin were affected based on the curing state of epoxy resin before MW irradiation. PMID:29587422
NASA Technical Reports Server (NTRS)
Giardini, A. A.
1986-01-01
Erratic pockets of erosion have occurred on the inner perimeter of the 404 rocket nozzle ring during liftoff firing. It is thought that it may be caused by pockets of volatile matter entrapped during manufacture. A thermal post cure was suggested as a possible means of outgassing such pockets, if they in fact do exist. To confirm an outgassing during a post cure and to establish a working upper temperature limit, thermal gravimetric and differential calorimetric analyses were made on a number of samples from two 404 rings supplied by the manufacturer. Continuous weight loss was observed over the temperature range explored (750 F) indicating outgassing, and a strong exothermic reaction occurs beginning about 390 F. Thus, an upper post cure temperature of 350 F is recommended. To determine the possible effect of a post cure on physical properties, the following tests will be made on matched sets of cured and post cured material: x-radiography (internal structure), linear dimensions, weight, porosity, cross ply thermal expansion, drop and double notch shear strengths, and tensional strength in the ply direction.
Tominaga, Yuichi; Shimamoto, Daisuke; Hotta, Yuji
2018-03-26
The interfacial adhesion of recycled carbon fiber (CF) reinforced epoxy composite heated by microwave (MW) irradiation were investigated by changing the curing state of the epoxy resin. The recycled CF was recovered from the composite, which was prepared by vacuum-assisted resin transfer molding, by thermal degradation at 500 or 600 °C. Thermogravimetric analysis showed that the heating at 600 °C caused rough damage to the CF surface, whereas recycled CF recovered at 500 °C have few defects. The interfacial shear strength (IFSS) between recycled CF and epoxy resin was measured by a single-fiber fragmentation test. The test specimen was heated by MW after mixing the epoxy resin with a curing agent or pre-curing, in order to investigate the curing effects on the matrix resin. The IFSSs of the MW-irradiated samples were significantly varied by the curing state of the epoxy resin and the surface condition of recycled CF, resulting that they were 99.5 to 131.7% of oven heated samples Furthermore, rheological measurements showed that the viscosity and shrinking behaviors of epoxy resin were affected based on the curing state of epoxy resin before MW irradiation.
Achieving interconnected pore architecture in injectable PolyHIPEs for bone tissue engineering.
Robinson, Jennifer L; Moglia, Robert S; Stuebben, Melissa C; McEnery, Madison A P; Cosgriff-Hernandez, Elizabeth
2014-03-01
Template polymerization of a high internal phase emulsion (polyHIPE) is a relatively new method to produce tunable high-porosity scaffolds for tissue regeneration. This study focuses on the development of biodegradable injectable polyHIPEs with interconnected porosity that have the potential to fill bone defects and enhance healing. Our laboratory previously fabricated biodegradable polyHIPEs that cure in situ upon injection; however, these scaffolds possessed a closed-pore morphology, which could limit bone ingrowth. To address this issue, HIPEs were fabricated with a radical initiator dissolved in the organic phase rather than the aqueous phase of the emulsion. Organic-phase initiation resulted in macromer densification forces that facilitated pore opening during cure. Compressive modulus and strength of the polyHIPEs were found to increase over 2 weeks to 43±12 MPa and 3±0.2 MPa, respectively, properties comparable to cancellous bone. The viscosity of the HIPE before cure (11.0±2.3 Pa·s) allowed for injection and filling of the bone defect, retention at the defect site during cure under water, and microscale integration of the graft with the bone. Precuring the materials before injection allowed for tuning of the work and set times. Furthermore, storage of the HIPEs before cure for 1 week at 4°C had a negligible effect on pore architecture after injection and cure. These findings indicate the potential of these emulsions to be stored at reduced temperatures and thawed in the surgical suite before injection. Overall, this work highlights the potential of interconnected propylene fumarate dimethacrylate polyHIPEs as injectable scaffolds for bone tissue engineering.
Nitrite, nitrite alternatives, and the control of Clostridium botulinum in cured meats.
Pierson, M D; Smoot, L A
1982-01-01
Historically, nitrite has been a component of meat-curing additives for several centuries. In recent years the safety of nitrite as an additive in cured meats has been questioned mainly because of the possible formation of carcinogenic nitrosamines. Nitrite has many important functions in meat curing including its role in color development, flavor, antioxidant properties, and antimicrobial activity. The inhibition of Clostridium botulinum growth and toxin production is an especially important antimicrobial property of nitrite. This review discusses the effects of processing, curing ingredients (especially nitrite), and storage of cured meats in relation to the control of C. botulinum. If nitrite is eliminated from cured meats or the level of usage decreased, then alternatives for the antibotulinal function of nitrite need to be considered. Several potential alternatives including sorbates, parabens, and biological acidulants are discussed.
Orihuel, Alejandra; Bonacina, Julieta; Vildoza, María José; Bru, Elena; Vignolo, Graciela; Saavedra, Lucila; Fadda, Silvina
2018-05-01
The aim of this work was to evaluate the effect of meat curing agents on the bioprotective activity of the bacteriocinogenic strain, Enterococcus (E.) mundtii CRL35 against Listeria (L.) monocytogenes during meat fermentation. The ability of E. mundtii CRL35 to grow, acidify and produce bacteriocin in situ was assayed in a meat model system in the presence of curing additives (CA). E. mundtii CRL35 showed optimal growth and acidification rates in the presence of CA. More importantly, the highest bacteriocin titer was achieved in the presence of these food agents. In addition, the CA produced a statistical significant enhancement of the enterocin CRL35 activity. This positive effect was demonstrated in vitro in a meat based culture medium, by time-kill kinetics and finally by using a beaker sausage model with a challenge experiment with the pathogenic L. monocytogenes FBUNT strain. E. mundtii CRL35 was found to be a promising strain of use as a safety adjunct culture in meat industry and a novel functional supplement for sausage fermentation, ensuring hygiene and quality of the final product. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effect of hydrated lime on compressive strength mortar of fly ash laterite soil geopolymer mortar
NASA Astrophysics Data System (ADS)
Wangsa, F. A.; Tjaronge, M. W.; Djamaluddin, A. R.; Muhiddin, A. B.
2017-11-01
This paper explored the suitability of fly ash, hydrated lime, and laterite soil with several activator (sodium hydroxide and sodium tiosulfate) to produce geopolymer mortar. Furthermore, the heat that released by hydrated lime was used instead of oven curing. In order to produce geopolymer mortar without oven curing, three variations of curing condition has been applied. Based on the result, all the curing condition showed that the hardener mortar can be produced and exhibited the increasing of compressive strength of geopolymer mortar from 3 days to 7 days without oven curing.
Energy curable compositions having improved cure speeds
Halm, L.W.
1993-05-18
The composition and method provide improved physical properties and cure speed of polyurethane precursors, with or without free radical polymerizable monomers or oligomers present, by use of a two component catalyst system. The resin blend can be activated with a latent organometallic catalyst combined with an organic peroxide which can be a hydroperoxide or an acyl peroxide to decrease the cure time while increasing the break energy and tangent modulus of the system.
Energy curable compositions having improved cure speeds
Halm, Leo W.
1993-01-01
A composition and method provide improved physical properties and cure speed of polyurethane precursors, with or without free radical polymerizable monomers or oligomers present, by use of a two component catalyst system. The resin blend can be activated with a latent organometallic catalyst combined with an organic peroxide which can be a hydroperoxide or an acyl peroxide to decrease the cure time while increasing the break energy and tangent modulus of the system.
[Methods Used for Monitoring Cure Reactions in Real-time in an Autoclave
NASA Technical Reports Server (NTRS)
Cooper, John B.; Wise, Kent L.; Jensen, Brian J. (Technical Monitor)
2000-01-01
The goal of the research was to investigate methods for monitoring cure reactions in real-time in an autoclave. This is of particular importance to NASA Langley Research Center because polyimides were proposed for use in the High Speed Civil Transport (HSCT) program. Understanding the cure chemistry behind the polyimides would allow for intelligent processing of the composites made from their use. This work has led to two publications in peer-reviewed journals and a patent. The journal articles are listed as Appendix A which is on the instrument design of the research and Appendix B which is on the cure chemistry. Also, a patent has been awarded for the instrumental design developed under this grant which is given as Appendix C. There has been a significant amount of research directed at developing methods for monitoring cure reactions in real-time within the autoclave. The various research efforts can be categorized as methods providing either direct chemical bonding information or methods that provide indirect chemical bonding information. Methods falling into the latter category are fluorescence, dielectric loss, ultrasonic and similar type methods. Correlation of such measurements with the underlying chemistry is often quite difficult since these techniques do not allow monitoring of the curing chemistry which is ultimately responsible for material properties. Direct methods such as vibrational spectroscopy, however, can often be easily correlated with the underlying chemistry of a reaction. Such methods include Raman spectroscopy, mid-IR absorbance, and near-IR absorbance. With the recent advances in fiber-optics, these spectroscopic techniques can be applied to remote on-line monitoring.
Cure fraction model with random effects for regional variation in cancer survival.
Seppä, Karri; Hakulinen, Timo; Kim, Hyon-Jung; Läärä, Esa
2010-11-30
Assessing regional differences in the survival of cancer patients is important but difficult when separate regions are small or sparsely populated. In this paper, we apply a mixture cure fraction model with random effects to cause-specific survival data of female breast cancer patients collected by the population-based Finnish Cancer Registry. Two sets of random effects were used to capture the regional variation in the cure fraction and in the survival of the non-cured patients, respectively. This hierarchical model was implemented in a Bayesian framework using a Metropolis-within-Gibbs algorithm. To avoid poor mixing of the Markov chain, when the variance of either set of random effects was close to zero, posterior simulations were based on a parameter-expanded model with tailor-made proposal distributions in Metropolis steps. The random effects allowed the fitting of the cure fraction model to the sparse regional data and the estimation of the regional variation in 10-year cause-specific breast cancer survival with a parsimonious number of parameters. Before 1986, the capital of Finland clearly stood out from the rest, but since then all the 21 hospital districts have achieved approximately the same level of survival. Copyright © 2010 John Wiley & Sons, Ltd.
Rapid Prototyping of Composite Structures
NASA Technical Reports Server (NTRS)
Colton, Jonathan S.
1998-01-01
This progress report for the project Rapid Production of Composite Structures covers the period from July 14, 1997 to June 30, 1998. It will present a short overview of the project, followed by the results to date and plans for the future. The goal of this research is to provide a minimum 100x reduction in the time required to produce arbitrary, laminated products without the need for a separate mold or an autoclave. It will accomplish this by developing the science underlying the rapid production of composite structures, specifically those of carbon fiber-epoxy materials. This scientific understanding will be reduced to practice in a demonstration device that will produce a part on the order of 12" by 12" by 6". Work in the past year has focussed on developing an understanding of the materials issues and of the machine design issues. Our initial goal was to use UV cureable resins to accomplish full cure on the machine. Therefore, we have centered our materials work around whether or not UV cureable resins will work. Currently, the answer seems to be that they will not work, because UV light cannot penetrate the carbon fibers, and because no "shadow" curing seems to occur. As a result, non-UV cureable resins are being investigated. This has resulted in a change in the machine design focus. We are now looking into a "dip and place" machine design, whereby a prepreg layer would have one side coated with a curing agent, and then would be placed onto the previous layer. This would lead to cure at the interface, but not to the top of the layer. The formulation of the resins to accomplish this task at room or slightly elevated temperatures is being investigated, as is the machine design needed to apply the curing agent and then cure or partially cure the part. A final, out-of-autoclave, post-cure may be needed with this strategy, as final cure on the machine may not be possible, as it was for the initial UV cure strategy. The remainder of this report details the progress in the materials and machine design areas. Materials Development The material system must be designed to fulfill the following requirements: to reduce the time and labor requirements of typical cure cycles; to reduce the thermal stresses developed during conventional heat curing; and to develop a structure that the build sequence requires. In order to accomplish these goals, there have been parallel tracks of investigation. One area has tested photopolymerizable (ultraviolet (UV) curable) materials and combinations of these materials with standard heat curing resins. The second area has investigated resins that cure rapidly at room or low heat temperatures. The main goal of these investigations has been to identify a system that will rapidly set or cure at room temperature during a tape lay-up process and hold its structure during a post-cure cycle.
Lise, Diogo Pedrollo; Van Ende, Annelies; De Munck, Jan; Yoshihara, Kumiko; Nagaoka, Noriyuki; Cardoso Vieira, Luiz Clovis; Van Meerbeek, Bart
2018-02-01
To assess light irradiance (LI) delivered by two light-curing units (LCU's) and to measure the degree of conversion (DC) of three composite cements, when cured through different thicknesses of two novel CAD-CAM block materials. 100-μm-thick films of a dual-curable composite cement (G-CEM LinkAce, GC), a light-curable flowable resin-based composite (RBC) (G-ænial Universal Flo, GC) and a micro-hybrid RBC (G-ænial Posterior, GC) were investigated as luting agents. Two 'polymer-ceramic' CAD-CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were sectioned in slabs with different thicknesses (1, 3 and 5mm). LI at the bottom of the specimens was measured using a calibrated spectrometer, while being light-cured through the CAD-CAM block slabs for 40s with a low- (±500mW/cm 2 ) or high- (±1,600mW/cm 2 ) irradiance LCU (n=5). After light-curing, micro-Raman spectra of the composite films were acquired to determine DC at 5min, 10min, 1h and 24h. LI data were statistically analyzed by Kruskal-Wallis followed by post-hoc comparisons, while a linear mixed-effect model was applied for the DC analysis. In addition, the CAD-CAM blocks ultrastructure was characterized upon argon-ion slicing using scanning transmission electron microscopy (STEM). Finally, light transmission (LT) through each CAD-CAM block material was assessed using a spectrophotometer. Curing-light attenuation and DC were significantly influenced by thickness and type of the overlying material. LCU only had a significant effect on DC of the micro-hybrid RBC. DC significantly increased over time for all composite cements. CAD-CAM block structural analysis revealed a relatively small and homogenous filler configuration (mean filler size of 0.2-0.5μm) for Cerasmart, while Enamic contained ceramic grains varying in shape and size (1-10μm), which were interconnected by the polymer-based network. LT was much higher at a wavelength range of 300-800nm for Cerasmart than for Enamic. Light-curable composite cements can be cured through a restoration up to 2.7-mm thickness, depending on the kind of CAD-CAM material. A high-irradiance LCU only has a limited effect on the maximum thickness of the polymer-ceramic CAD-CAM material that can be cured through. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Italian cancer figures, report 2014: Prevalence and cure of cancer in Italy.
2014-01-01
This Report intends to estimate the total number of people still alive in 2010 after cancer diagnosis in Italy, regardless of the time since diagnosis, and to project these estimates to 2015. This study is also aimed to estimate the number of already cured cancer patients, whose mortality rates have become undistinguishable from that of the general population of the same age and sex. The study took advantage of the information from the AIRTUM database, which included 29 Cancer Registries (covering 21 million people, 35% of the Italian population). A total of 1,624,533 cancer cases diagnosed between 1976 and 2009 contributed to the study. For each registry, the observed prevalence was calculated. Prevalence for lengths of time exceeding the maximum duration of the registration and of the complete prevalence were derived by applying an estimated correction factor, the completeness index. This index was estimated by means of statistical regression models using cancer incidence and survival data available in registries with 18 years of observation or more. For 50 types or combinations of neoplasms, complete prevalence was estimated at 1.1.2010 as an absolute number and as a proportion per 100,000 inhabitants by sex, age group, area of residence, and years since diagnosis. Projections of complete prevalence for 1.1.2015 were computed under the assumption of a linear trend of the complete prevalence observed until 2010. Validated mixture cure models were used to estimate: the cure fraction, that is the proportion of patients who, starting from the time of diagnosis, are expected to reach the same mortality rate of the general population; the conditional relative survival (CRS), that is the cumulative probability of surviving some additional years, given that patients already survived a certain number of years; the time to cure, that is the number of years necessary so that conditional survival in the following five years (5-year CRS) exceeds the conventional threshold of 95% (i.e., mortality rates in cancer patients become undistinguishable compared to those of the general population); the proportion of patients already cured, i.e., people alive since a number of years exceeding time to cure. As of 1.1.2010, it was estimated that 2,587,347 people were alive after a cancer diagnosis, corresponding to 4.4% of the Italian population. A relevant geographical heterogeneity emerged, with a prevalence above 5% in northern registries and below 4% in southern areas. Men were 45% of the total (1,154,289) and women 55% (1,433,058). In the population aged 75 years or more, the proportions of prevalent cases were 20% in males and 13% in females, 11% between 60 and 74 years of age in both sexes. Nearly 600,000 Italian women were alive after a breast cancer diagnosis (41% of all women with this neoplasm), followed by women with cancers of the colon rectum (12%), corpus uteri (7%), and thyroid (6%). In men, 26% of prevalent cases (295,624) were patients with prostate cancer, 16% with either bladder or colon rectum cancer. The projections for 1.1.2015 are of three million (3,036,741) people alive after a cancer diagnosis, 4.9% of the Italian population; with a 20% increase for males and 15% for females, compared to 2010. The cure fractions were heterogeneous according to cancer type and age. Estimates obtained as the sum of cure fractions for all cancer types showed that more than 60% of patients diagnosed below the age of 45 years will reach the same mortality rate of the general population. This proportion decreased with increasing age and it was <30% for cancer diagnosed after the age of 74 years. It was observed that 60% of all prevalent cases (1,543,531 people or 2.6% of overall Italian population) had been diagnosed >5 years earlier (long-term survivors). Time to cure (5-year CRS>95%) was reached in <10 years by patients with cancers of the stomach, colon rectum, pancreas, corpus and cervix uteri, brain, and Hodgkin lymphoma. Mortality rates similar to the ones reported by the general population were reached after approximately 20 years for breast and prostate cancer patients. Five-year CRS remained <95% for >25 years after cancer diagnosis in patients with liver and larynx cancers, non-Hodgkin lymphoma, myeloma, and leukaemia. Time to cure was reached by 27% (20% in men and 33% in women) of all people living after a cancer diagnosis, defined as already cured. The study showed a steady increase over time (nearly +3% per year) of prevalent cases in Italy. A quarter of Italian cancer patients alive in 2010 can be considered as already cured. The AIRTUM Report 2014 describes characteristics of cancer patients and former-patients for 50 cancer types or combinations by sex and age. This detailed information promotes the conduction of studies aimed at expanding the current knowledge on the quality of life of these patients during and after the active phase of treatments (prevalence according to health status), on the long-term effects of treatments (in particular for paediatric patients), on the cost profile of cancer patients, and on rare tumours. All these observations have a high potential impact on health planning, clinical practice, and, most of all, patients' perspective.
NASA Technical Reports Server (NTRS)
Clemons, J. M.; Penn, B. G.; Ledbetter, Frank E., III; Daniels, J. G.
1987-01-01
Improvement upon recommended procedures saves time and expense. Autoclave molding in vacuum bag cleaner if adhesive-backed covering placed around caul plate as well as on mold plate. Covering easy to remove after curing and leaves caul plate free of resin deposits.
2011-01-01
Background In aquaculture breeding, resistance against infectious diseases is commonly assessed as time until death under exposure to a pathogen. For some diseases, a fraction of the individuals may appear as "cured" (non-susceptible), and the resulting survival time may thus be a result of two confounded underlying traits, i.e., endurance (individual hazard) and susceptibility (whether at risk or not), which may be accounted for by fitting a cure survival model. We applied a cure model to survival data of Pacific white shrimp (Penaeus vannamei) challenged with the Taura syndrome virus, which is one of the major pathogens of Panaeid shrimp species. Methods In total, 15,261 individuals of 513 full-sib families from three generations were challenge-tested in 21 separate tests (tanks). All challenge-tests were run until mortality naturally ceased. Time-until-event data were analyzed with a mixed cure survival model using Gibbs sampling, treating susceptibility and endurance as separate genetic traits. Results Overall mortality at the end of test was 28%, while 38% of the population was considered susceptible to the disease. The estimated underlying heritability was high for susceptibility (0.41 ± 0.07), but low for endurance (0.07 ± 0.03). Furthermore, endurance and susceptibility were distinct genetic traits (rg = 0.22 ± 0.25). Estimated breeding values for endurance and susceptibility were only moderately correlated (0.50), while estimated breeding values from classical models for analysis of challenge-test survival (ignoring the cured fraction) were closely correlated with estimated breeding values for susceptibility, but less correlated with estimated breeding values for endurance. Conclusions For Taura syndrome resistance, endurance and susceptibility are apparently distinct genetic traits. However, genetic evaluation of susceptibility based on the cure model showed clear associations with standard genetic evaluations that ignore the cure fraction for these data. Using the current testing design, genetic variation in observed survival time and absolute survival at the end of test were most likely dominated by genetic variation in susceptibility. If the aim is to reduce susceptibility, earlier termination of the challenge-test or back-truncation of the follow-up period should be avoided, as this may shift focus of selection towards endurance rather than susceptibility. PMID:21418636
Effect of disposable infection control barriers on light output from dental curing lights.
Scott, Barbara A; Felix, Corey A; Price, Richard B T
2004-02-01
To prevent contamination of the light guide on a dental curing light, barriers such as disposable plastic wrap or covers may be used. This study compared the effect of 3 disposable barriers on the spectral output and power density from a curing light. The hypothesis was that none of the barriers would have a significant clinical effect on the spectral output or the power density from the curing light. Three disposable barriers were tested against a control (no barrier). The spectra and power from the curing light were measured with a spectrometer attached to an integrating sphere. The measurements were repeated on 10 separate occasions in a random sequence for each barrier. Analysis of variance (ANOVA) followed by Fisher's protected least significant difference test showed that the power density was significantly less than control (by 2.4% to 6.1%) when 2 commercially available disposable barriers were used (p < 0.05). There was no significant difference in the power density when general-purpose plastic wrap was used (p > 0.05). The effect of each of the barriers on the power output was small and probably clinically insignificant. ANOVA comparisons of mean peak wavelength values indicated that none of the barriers produced a significant shift in the spectral output relative to the control ( p > 0.05). Two of the 3 disposable barriers produced a significant reduction in power density from the curing light. This drop in power was small and would probably not adversely affect the curing of composite resin. None of the barriers acted as light filters.
NASA Astrophysics Data System (ADS)
Adiwijaya; Hamada, H.; Sagawa, Y.; Yamamoto, D.
2017-11-01
Generally, in the concrete industry, several billion tons of fresh water are annually used for mixing water, curing water and cleaning water. Nevertheless, the utilization of seawater in the concrete industry is prohibited, because it increases the risk of corrosion of steel bars in concrete. This study presents strength characteristics and porosity of seawater mixed concrete and tap water mixed concrete incorporating Ground Granulated Blast-Furnace Slag (GGBS) with water-binder ratio (W/B) of 40%, 50% and 60%. The influence of seawater mixing, GGBS and curing conditions such as tap water curing (TC), seawater curing (SC) and air curing (AC) on the strength and porosity of concrete were evaluated. Based on investigation result, it was shown that there is no significant influence of seawater mixing in improving strength of GGBS concrete up to 365 days in TC and SC. Effectiveness of seawater-mixing on strength enhancement of GGBS concrete is larger in air curing than in water curing. Porosity of seawater-mixed concrete is decreased compared to tap water-mixed concrete in all curing conditions.
Tai, Patricia; Yu, Edward; Cserni, Gábor; Vlastos, Georges; Royce, Melanie; Kunkler, Ian; Vinh-Hung, Vincent
2005-01-01
Background The present commonly used five-year survival rates are not adequate to represent the statistical cure. In the present study, we established the minimum number of years required for follow-up to estimate statistical cure rate, by using a lognormal distribution of the survival time of those who died of their cancer. We introduced the term, threshold year, the follow-up time for patients dying from the specific cancer covers most of the survival data, leaving less than 2.25% uncovered. This is close enough to cure from that specific cancer. Methods Data from the Surveillance, Epidemiology and End Results (SEER) database were tested if the survival times of cancer patients who died of their disease followed the lognormal distribution using a minimum chi-square method. Patients diagnosed from 1973–1992 in the registries of Connecticut and Detroit were chosen so that a maximum of 27 years was allowed for follow-up to 1999. A total of 49 specific organ sites were tested. The parameters of those lognormal distributions were found for each cancer site. The cancer-specific survival rates at the threshold years were compared with the longest available Kaplan-Meier survival estimates. Results The characteristics of the cancer-specific survival times of cancer patients who died of their disease from 42 cancer sites out of 49 sites were verified to follow different lognormal distributions. The threshold years validated for statistical cure varied for different cancer sites, from 2.6 years for pancreas cancer to 25.2 years for cancer of salivary gland. At the threshold year, the statistical cure rates estimated for 40 cancer sites were found to match the actuarial long-term survival rates estimated by the Kaplan-Meier method within six percentage points. For two cancer sites: breast and thyroid, the threshold years were so long that the cancer-specific survival rates could yet not be obtained because the SEER data do not provide sufficiently long follow-up. Conclusion The present study suggests a certain threshold year is required to wait before the statistical cure rate can be estimated for each cancer site. For some cancers, such as breast and thyroid, the 5- or 10-year survival rates inadequately reflect statistical cure rates, and highlight the need for long-term follow-up of these patients. PMID:15904508
Degree of conversion of two lingual retainer adhesives cured with different light sources.
Usümez, Serdar; Büyükyilmaz, Tamer; Karaman, Ali Ihya; Gündüz, Beniz
2005-04-01
The aim of this study was to evaluate the degree of conversion (DC) of two lingual retainer adhesives, Transbond Lingual Retainer (TLR) and Light Cure Retainer (LCR), cured with a fast halogen light, a plasma arc light and a light-emitting diode (LED) at various curing times. A conventional halogen light served as the control. One hundred adhesive samples (five per group) were cured for 5, 10 or 15 seconds with an Optilux 501 (fast halogen light), for 3, 6 or 9 seconds with a Power Pac (plasma arc light), or for 10, 20 or 40 seconds with an Elipar Freelight (LED). Samples cured for 40 seconds with the conventional halogen lamp were used as the controls. Absorbance peaks were recorded using Fourier transform infrared (FT-IR) spectroscopy. DC values were calculated. Data were analysed using Kruskal-Wallis and Mann-Whitney U-tests. For the TLR, the highest DC values were achieved in 6 and 9 seconds with the plasma arc light. Curing with the fast halogen light for 15 seconds and with the LED for 40 seconds produced statistically similar DC values, but these were lower than those with the plasma arc light. All of these light exposures yielded a statistically significantly higher DC than 40 seconds of conventional halogen light curing. The highest DC value for the LCR was achieved in 15 seconds with the fast halogen light, then the plasma arc light curing for 6 seconds. These two combinations produced a statistically significantly higher DC when compared with the 40 seconds of conventional halogen light curing. The lowest DC for the LCR was achieved with 10 seconds of LED curing. The overall DC of the LCR was significantly higher than that of the TLR. The results suggest that a similar or higher DC than the control values could be achieved in 6-9 seconds by plasma arc curing, in 10-15 seconds by fast halogen curing or in 20 seconds by LED curing.
Barnes, Emm
2007-12-01
During the course of the 1960s and 1970s, acute leukaemia in childhood ceased to be invariably fatal and was recategorized as curable. The meaning of cure in this case, however, was problematic, as it was impossible for physicians to be certain that cancer would not return. This paper uses historical methods to explore how remission was understood by families with children with acute leukaemia during the period in which the first cures were announced, roughly 1972-77. These comprised documentary analysis of records of the Medical Research Council's leukaemia working parties, published papers and letters on treatments for childhood leukaemia, and interviews with eight UK paediatric oncologists practising in UK hospitals in the 1960s and 1970s. Two approaches to defining 'cure' in leukaemia can be identified. The first relied on statistical assessment of survival rates. I argue that the concept of 'indefinite remission' came to serve for researchers and clinicians as a proxy measure of cure. However, the concept of 'indefinite remission' left many patients and their families quite uncertain as to whether a cure had really happened. A second approach to defining cure therefore developed. Faced with uncertainty, patients, parents and psychologists sought to develop alternative measures of success--including the notion of 'psychological cure'--that brought forward the moment of cure and its relief. Changing conceptualizations of leukaemia shaped and were shaped by negotiations over the meaning of 'remission' and 'cure'. On the one hand, the statistical definition of cure was not available for years. On the other hand, psychological cure could begin from the time of first remission, even if medical absolution was not available for years.
NASA Technical Reports Server (NTRS)
Hou, Jean W.
1985-01-01
The thermal analysis and the calculation of thermal sensitivity of a cure cycle in autoclave processing of thick composite laminates were studied. A finite element program for the thermal analysis and design derivatives calculation for temperature distribution and the degree of cure was developed and verified. It was found that the direct differentiation was the best approach for the thermal design sensitivity analysis. In addition, the approach of the direct differentiation provided time histories of design derivatives which are of great value to the cure cycle designers. The approach of direct differentiation is to be used for further study, i.e., the optimal cycle design.
2006-01-01
in progress 8 PvDBP Polymorphisms Study completed; publication in progress 9 Tafenoquine Cure /Radical Cure Dose Ranging NIH In life completed Jan...and II, as possibly phase III testing. We will continue efforts for tafenoquine development, especially towards an indication of radical cure for...disease (prophylaxis) and to cure the infection (therapeutic). Antimalarial drug screening in the rhesus monkey model is very effective for making
Accelerated aging effects on surface hardness and roughness of lingual retainer adhesives.
Ramoglu, Sabri Ilhan; Usumez, Serdar; Buyukyilmaz, Tamer
2008-01-01
To test the null hypothesis that accelerated aging has no effect on the surface microhardness and roughness of two light-cured lingual retainer adhesives. Ten samples of light-cured materials, Transbond Lingual Retainer (3M Unitek) and Light Cure Retainer (Reliance) were cured with a halogen light for 40 seconds. Vickers hardness and surface roughness were measured before and after accelerated aging of 300 hours in a weathering tester. Differences between mean values were analyzed for statistical significance using a t-test. The level of statistical significance was set at P < .05. The mean Vickers hardness of Transbond Lingual Retainer was 62.8 +/- 3.5 and 79.6 +/- 4.9 before and after aging, respectively. The mean Vickers hardness of Light Cure Retainer was 40.3 +/- 2.6 and 58.3 +/- 4.3 before and after aging, respectively. Differences in both groups were statistically significant (P < .001). Following aging, mean surface roughness was changed from 0.039 microm to 0.121 microm and from 0.021 microm to 0.031 microm for Transbond Lingual Retainer and Light Cure Retainer, respectively. The roughening of Transbond Lingual Retainer with aging was statistically significant (P < .05), while the change in the surface roughness of Light Cure Retainer was not (P > .05). Accelerated aging significantly increased the surface microhardness of both light-cured retainer adhesives tested. It also significantly increased the surface roughness of the Transbond Lingual Retainer.
A new UV-curing elastomeric substrate for rapid prototyping of microfluidic devices
NASA Astrophysics Data System (ADS)
Alvankarian, Jafar; Yeop Majlis, Burhanuddin
2012-03-01
Rapid prototyping in the design cycle of new microfluidic devices is very important for shortening time-to-market. Researchers are facing the challenge to explore new and suitable substrates with simple and efficient microfabrication techniques. In this paper, we introduce and characterize a UV-curing elastomeric polyurethane methacrylate (PUMA) for rapid prototyping of microfluidic devices. The swelling and solubility of PUMA in different chemicals is determined. Time-dependent measurements of water contact angle show that the native PUMA is hydrophilic without surface treatment. The current monitoring method is used for measurement of the electroosmotic flow mobility in the microchannels made from PUMA. The optical, physical, thermal and mechanical properties of PUMA are evaluated. The UV-lithography and molding process is used for making micropillars and deep channel microfluidic structures integrated to the supporting base layer. Spin coating is characterized for producing different layer thicknesses of PUMA resin. A device is fabricated and tested for examining the strength of different bonding techniques such as conformal, corona treating and semi-curing of two PUMA layers in microfluidic application and the results show that the bonding strengths are comparable to that of PDMS. We also report fabrication and testing of a three-layer multi inlet/outlet microfluidic device including a very effective fluidic interconnect for application demonstration of PUMA as a promising new substrate. A simple micro-device is developed and employed for observing the pressure deflection of membrane made from PUMA as a very effective elastomeric valve in microfluidic devices.
Effect of organo clay on curing, mechanical and dielectric properties of NR/SBR blends
NASA Astrophysics Data System (ADS)
Ravikumar, K.; Joseph, Reji; Ravichandran, K.
2018-04-01
Natural rubber (NR) and styrene butadiene rubber (SBR) based elastomeric blends reinforced with organically modified Sodium bentonite clay were prepared by two roll mills. Vulcanization parameters such as minimum and maximum torque values scorch and cure times are measured by Oscillating Disc Rheometer. Mechanical properties such as Tensile strength, modulus at 100%, 200% and 300% elongation and elongation at break and Hardness were measured by Universal testing machine and Durometer Shore A hardness meter respectively. Dielectric properties such as dielectric constant (ε’), dissipation factor (tanδ) and volume resistivity (ρv) were measured at room temperature. The curing studies show that torque values are increasing in NR/SBR blends by increase NR content. The scorch and optimum cure time in NR/SBR blends reinforced organo modified clay was found through increase in the SBR content. This may be due to better processing safety of the NR/SBR blends reinforced with organo modified clay. Mechanical properties show that addition of SBR in blends, tensile strength, elongation modulus increases, but 100% modulus slightly increases and no change was observed in Hardness. Dielectric studies show that dielectric constant of NR and SBR rubbers are almost same, it may due to their non-polar nature. But addition of SBR in NR/SBR blend, dielectric constant gradually increases and maximum value observed at 50/50 ratio. But no considerable change was observed in dissipation factor. Frequency dependant resistivity shows that volume resistivity was not changed with respect to frequency up to 3.5 kHz and beyond that the frequency dependence resistivity was found.
Rapid energy-efficient manufacturing of polymers and composites via frontal polymerization.
Robertson, Ian D; Yourdkhani, Mostafa; Centellas, Polette J; Aw, Jia En; Ivanoff, Douglas G; Goli, Elyas; Lloyd, Evan M; Dean, Leon M; Sottos, Nancy R; Geubelle, Philippe H; Moore, Jeffrey S; White, Scott R
2018-05-01
Thermoset polymers and composite materials are integral to today's aerospace, automotive, marine and energy industries and will be vital to the next generation of lightweight, energy-efficient structures in these enterprises, owing to their excellent specific stiffness and strength, thermal stability and chemical resistance 1-5 . The manufacture of high-performance thermoset components requires the monomer to be cured at high temperatures (around 180 °C) for several hours, under a combined external pressure and internal vacuum 6 . Curing is generally accomplished using large autoclaves or ovens that scale in size with the component. Hence this traditional curing approach is slow, requires a large amount of energy and involves substantial capital investment 6,7 . Frontal polymerization is a promising alternative curing strategy, in which a self-propagating exothermic reaction wave transforms liquid monomers to fully cured polymers. We report here the frontal polymerization of a high-performance thermoset polymer that allows the rapid fabrication of parts with microscale features, three-dimensional printed structures and carbon-fibre-reinforced polymer composites. Precise control of the polymerization kinetics at both ambient and elevated temperatures allows stable monomer solutions to transform into fully cured polymers within seconds, reducing energy requirements and cure times by several orders of magnitude compared with conventional oven or autoclave curing approaches. The resulting polymer and composite parts possess similar mechanical properties to those cured conventionally. This curing strategy greatly improves the efficiency of manufacturing of high-performance polymers and composites, and is widely applicable to many industries.
2015-05-20
TEMPERATURES IN HIGH-TEMPERATURE THERMOSETTING POLYMERS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...temperature thermosetting polymer via dynamic mechanical analysis alone. These difficulties result from the residual cure of samples heated beyond their...98) Prescribed by ANSI Std. 239.18 Effect of In-Situ Cure on Measurement of Glass Transition Temperatures in High-Temperature Thermosetting
Shpotyuk, Olha; Adamiak, Stanislaw; Bezvushko, Elvira; Cebulski, Jozef; Iskiv, Maryana; Shpotyuk, Oleh; Balitska, Valentina
2017-12-01
Light-curing volumetric shrinkage in dimethacrylate-based dental resin composites Dipol® is examined through comprehensive kinetics research employing nanoindentation measurements and nanoscale atomic-deficient study with lifetime spectroscopy of annihilating positrons. Photopolymerization kinetics determined through nanoindentation testing is shown to be described via single-exponential relaxation function with character time constants reaching respectively 15.0 and 18.7 s for nanohardness and elastic modulus. Atomic-deficient characteristics of composites are extracted from positron lifetime spectra parameterized employing unconstrained x3-term fitting. The tested photopolymerization kinetics can be adequately reflected in time-dependent changes observed in average positron lifetime (with 17.9 s time constant) and fractional free volume of positronium traps (with 18.6 s time constant). This correlation proves that fragmentation of free-volume positronium-trapping sites accompanied by partial positronium-to-positron traps conversion determines the light-curing volumetric shrinkage in the studied composites.
Micaceous Soil Strength And Permeability Improvement Induced By Microbacteria From Vegetable Waste
NASA Astrophysics Data System (ADS)
Omar, R. C.; Roslan, R.; Baharuddin, I. N. Z.; Hanafiah, M. I. M.
2016-11-01
Green technology method using vegetable waste are introduced in this paper for improvement of phyllite residual soil from UNITEN, Campus. Residual soil from phyllite are known as micaceous soils and it give problem in managing the stability of the slope especially in wet and extensively dry seasons. Micaceous soil are collected using tube sampler technique and mixed with liquid contain microorganism from fermented vegetable waste name as vege-grout to form remolded sample. The remolded sample are classify as 15.0%, 17.5%, 20.00% and 22.5% based on different incremental percentages of vege-grout. The curing time for the sample are 7, 14, 21, 28, and 35 days before the tests were conducted. Observation of the effect of treatment shows 20.0% of liquid contain Bacillus pasteurii and Bacillus Subtilis with 21 days curing time is the optimum value in strengthening the soil and improve the permeability.
Han, Youkui; Zhao, Hui; Xu, HongRui; Liu, Shuzhong; Li, Li; Jiang, Chunyang; Yang, Bingjun
2014-01-01
Gastrointestinal fistula is the most serious complication of esophageal and gastric cardiac cancer surgery. According to occurrence of organ, gastrointestinal fistula can be divided into anastomotic fistula, gastric fistula; According to occurrence site, fistula can be divided into cervical fistula, thoracic fistula; According to time of occurrence, can be divided into early, middle and late fistula. There are special types of fistula including ‘thoracic cavity’-stomach-bronchial fistula, ‘thoracic cavity’-stomach-aortic fistula. Early diagnosis needs familiarity with various types of clinical gastrointestinal fistulas. However, Prevention of gastrointestinal fistula is better than cure, including perioperative nutritional support, respiratory tract management, and acid suppression, positive treatment of complications, antibiotic prophylaxis, and gastrointestinal decompression and eating timing. Prevention can effectively reduce the incidence of postoperative gastrointestinal fistula. Collectively, early diagnosis and treatment, nutritional supports are key to reducing mortality of gastrointestinal fistula.
Adhesion at the interface in cured graphite fiber epoxy-amine resin composites
NASA Technical Reports Server (NTRS)
Needles, Howard L.; Alger, Kenneth W.; Okamoto, Robert
1987-01-01
The effect of high temperature curing on the interface between unsized or epoxy-sized graphite fiber tow and epoxy-amine resin was examined by scanning electron microscopy of compression and freeze fractured specimens. Little or no adhesion was found between the unsized graphite fiber tows and the epoxy-amine resin on curing at 165 C for 17 hrs. Epoxy-sized graphite fibers showed a similar lack of adhesion between the fiber tows and the epoxy-amine resin at 3 and 17 hr cures, although good penetration of the resin into the sized fiber tows had occurred. Interfacial bond strengths for the composites could not be effectively measured by compression fracture of specimens.
Quantifying Asphalt Emulsion-Based Chip Seal Curing Times Using Electrical Resistance Measurements.
DOT National Transportation Integrated Search
2017-04-15
Chip sealing typically consists of covering a pavement surface with asphalt emulsion into which aggregate chips are embedded. The asphalt emulsion cures through the evaporation of water, thus providing mechanical strength to adhere to the pavement wh...
Effects of Amine and Anhydride Curing Agents on the VARTM Matrix Processing Properties
NASA Technical Reports Server (NTRS)
Grimsley, Brian W.; Hubert, Pascal; Song, Xiaolan; Cano, Roberto J.; Loos, Alfred C.; Pipes, R. Byron
2002-01-01
To ensure successful application of composite structure for aerospace vehicles, it is necessary to develop material systems that meet a variety of requirements. The industry has recently developed a number of low-viscosity epoxy resins to meet the processing requirements associated with vacuum assisted resin transfer molding (VARTM) of aerospace components. The curing kinetics and viscosity of two of these resins, an amine-cured epoxy system, Applied Poleramic, Inc. VR-56-4 1, and an anhydride-cured epoxy system, A.T.A.R.D. Laboratories SI-ZG-5A, have been characterized for application in the VARTM process. Simulations were carried out using the process model, COMPRO, to examine heat transfer, curing kinetics and viscosity for different panel thicknesses and cure cycles. Results of these simulations indicate that the two resins have significantly different curing behaviors and flow characteristics.
Differences in interfacial bond strengths of graphite fiber-epoxy resin composites
NASA Technical Reports Server (NTRS)
Needles, H. L.
1985-01-01
The effect of epoxy-size and degree of cure on the interfacial bonding of an epoxy-amine-graphite fiber composite system is examined. The role of the fiber-resin interface in determining the overall mechanical properties of composites is poorly understood. A good interfacial adhesive bond is required to achieve maximum stress transfer to the fibers in composites, but at the same time some form of energy absorbing interfacial interaction is needed to achieve high fracture toughening. The incompatibility of these two processes makes it important to understand the nature and basic factors involved at the fiber-resin interface as stress is applied. The mechanical properties including interlaminar shear values for graphite fiber-resin composites are low compared to glass and boron-resin composites. These differences have been attributed to poor fiber-matrix adhesion. Graphite fibers are commonly subjected to post-treatments including application of organic sizing in order to improve their compatibility with the resin matrix and to protect the fiber tow from damage during processing and lay-up. In such processes, sized graphite fiber tow is impregnated with epoxy resin and then layed-up i nto the appropriate configuration. Following an extended ambient temperature cure, the graphite-resin composite structure is cured at elevated temperature using a programmed temperature sequence to cure and then cool the product.
NASA Astrophysics Data System (ADS)
Shekar, Yamini
This research investigates the nano-scale pore structure of cementitious mortars undergoing delayed ettringite formation (DEF) using small angle x-ray scattering (SAXS). DEF has been known to cause expansion and cracking during later ages (around 4000 days) in concrete that has been heat cured at temperatures of 70°C or above. Though DEF normally occurs in heat cured concrete, mass cured concrete can also experience DEF. Large crystalline pressures result in smaller pore sizes. The objectives of this research are: (1) to investigate why some samples expand early than later expansion, (2) to evaluate the effects of curing conditions and pore size distributions at high temperatures, and (3) to assess the evolution of the pore size distributions over time. The most important outcome of the research is the pore sizes obtained from SAXS were used in the development of a 3-stage model. From the data obtained, the pore sizes increase in stage 1 due to initial ettringite formation and in turn filling up the smallest pores. Once the critical pore size threshold is reached (around 20nm) stage 2 is formed due to cracking which tends to decrease in the pore sizes. Finally, in stage 3, the cracking continues, therefore increasing in the pore size.
López-Suevos, Francisco; Dickens, Sabine H.
2008-01-01
Objective Evaluate the effects of core structure and storage conditions on the mechanical properties of acid-resin modified composites and a control material by three-point bending and conversion measurements 15 min and 24 h after curing. Methods The monomers pyromellitic dimethacrylate (PMDM), biphenyldicarboxylic-acid dimethacrylate (BPDM), (isopropylidene-diphenoxy)bis(phthalic-acid) dimethacrylate (IPDM), oxydiphthalic-acid dimethacrylate (ODPDM), and Bis-GMA were mixed with triethyleneglycol dimethacrylate (TEGDMA) in a 40/60 molar ratio, and photo-activated. Composite bars (Barium-oxide-glass/resin = 3/1 mass ratio, (2 × 2 × 25) mm, n = 5) were light-cured for 1 min per side. Flexural strength (FS), elastic modulus (E), and work-of-fracture (WoF) were determined in three-point bending after 15 min (stored dry); and after 24 h under dry and wet storage conditions at 37 °C. Corresponding degrees of conversion (DC) were evaluated by Fourier transform infrared spectroscopy. Data was statistically analyzed (2-way analysis of variance, ANOVA, Holm-Sidak, p < 0.05). Results Post-curing significantly increased FS, E and DC in nearly all cases. WoF did not change, or even decreased with time. For all properties ANOVA found significant differences and interactions of time and material. Wet storage reduced the moduli and the other properties measured with the exception of FS and WoF of ODPDM; DC only decreased in BPDM and IPDM composites. Significance Differences in core structure resulted in significantly different physical properties of the composites studied with two phenyl rings connected by one ether linkage as in ODPDM having superior FS, WoF and DC especially after 24 h under wet conditions. As expected, post-curing significantly contributed to the final mechanical properties of the composites, while wet storage generally reduced the mechanical properties. PMID:17980422
HIV cure strategies: how good must they be to improve on current antiretroviral therapy?
Sax, Paul E; Sypek, Alexis; Berkowitz, Bethany K; Morris, Bethany L; Losina, Elena; Paltiel, A David; Kelly, Kathleen A; Seage, George R; Walensky, Rochelle P; Weinstein, Milton C; Eron, Joseph; Freedberg, Kenneth A
2014-01-01
We examined efficacy, toxicity, relapse, cost, and quality-of-life thresholds of hypothetical HIV cure interventions that would make them cost-effective compared to life-long antiretroviral therapy (ART). We used a computer simulation model to assess three HIV cure strategies: Gene Therapy, Chemotherapy, and Stem Cell Transplantation (SCT), each compared to ART. Efficacy and cost parameters were varied widely in sensitivity analysis. Outcomes included quality-adjusted life expectancy, lifetime cost, and cost-effectiveness in dollars/quality-adjusted life year ($/QALY) gained. Strategies were deemed cost-effective with incremental cost-effectiveness ratios <$100,000/QALY. For patients on ART, discounted quality-adjusted life expectancy was 16.4 years and lifetime costs were $591,400. Gene Therapy was cost-effective with efficacy of 10%, relapse rate 0.5%/month, and cost $54,000. Chemotherapy was cost-effective with efficacy of 88%, relapse rate 0.5%/month, and cost $12,400/month for 24 months. At $150,000/procedure, SCT was cost-effective with efficacy of 79% and relapse rate 0.5%/month. Moderate efficacy increases and cost reductions made Gene Therapy cost-saving, but substantial efficacy/cost changes were needed to make Chemotherapy or SCT cost-saving. Depending on efficacy, relapse rate, and cost, cure strategies could be cost-effective compared to current ART and potentially cost-saving. These results may help provide performance targets for developing cure strategies for HIV.
Ultrasonic Coating and Holographic Exposure Technology. Phase 1
2015-09-01
introducing plaques to cure, which allowed the UV lamps to warm up. Temperature inside the UV oven could reach 35 °C if left on continuously. Curing time for...the deposition of thin films using an ultrasonic spray coater and patterning of the films using an ultraviolet ( UV ) laser. The main objectives for...required, and include such items as a corona discharge device, a UV curing oven, hot plate, and jigging for optics that were fabricated at Revision. Test
Ferreira, Sabrina Queji; Costa, Thays Regina; Klein-Júnior, Celso Afonso; Accorinte, Maria de; Meier, Márcia Margarete; Loguercio, Alessandro Dourado; Reis, Alessandra
2011-06-01
This study evaluated the effect of prolonged polymerization times on the microtensile resin-dentin bond strength (μTBS), degree of conversion of adhesive films (DC) and silver nitrate uptake (SNU) for an ethanol/water- (Adper Single Bond 2, [SB]) and an acetone-based (One Step Plus, [OS]) etch-and-rinse adhesive. Thirty caries-free extracted molars were included in this study. The occlusal enamel of all teeth was removed by wet grinding the occlusal enamel on 180-grit SiC paper. Adhesives were applied according to the manufacturer's instructions, but they were light cured for 10, 20 and 40 s at 600 mW/cm2. Bonded sticks (0.6 mm2) were tested in tension (0.5 mm/min). Two bonded sticks from each tooth were immersed in an ammoniacal solution of silver nitrate (24 h), photodeveloped (8 h), and analyzed by SEM. The DC of the adhesives was evaluated under Fourier Transformed Infra-Red spectroscopy (FTIR). Data for each property were analyzed by two-way ANOVA and Tukey's test (α = 0.05). Statistically higher μTBS and DC were observed for SB and OS when both adhesives were light cured for 40 s in comparison with 10 s. For OS, the μTBS in the 20- and 40-s groups did not differ statistically, while for SB it did. Higher prolonged exposure times did not prevent nanoleakage within the hybrid layer for all groups regardless of the adhesive. This study supports the hypothesis that exposure times longer than those recommended can improve the degree of conversion of adhesive films and the immediate resin-dentin bonds. The prolonged curing times (20 and 40 s) for polymerization of simplified adhesives resulted in an increase in the degree of conversion of the adhesive films and resin-dentin bond strengths but did not reduce the nanoleakage within the hybrid layer.
Kessler, Lynn; Palla, Jyothsna; Baru, Joshua S; Onyenwenyi, Chioma; George, Amrutha M; Lucas, Brian P
2014-07-01
Radioactive iodine (RAI) is commonly used in the treatment of hyperthyroidism but is not uniformly successful. Lithium increases thyroidal iodine retention without reducing iodide uptake, increasing the radiation dose to the thyroid when administered with RAI. Although these actions suggest that adjuvant lithium may increase the efficacy of RAI, its role as an adjunct to RAI remains contentious. To evaluate the safety and efficacy of adding lithium to RAI to treat hyperthyroidism. Relevant studies were identified by a search of Medline and the Cochrane Central Register of Controlled Trials. To be included, a study had to be a controlled trial comparing the effect of RAI alone to RAI with lithium in the treatment of hyperthyroidism. Relevant data were extracted and meta-analyses were performed. Of the 75 identified studies, 6 met the inclusion criteria; 4 of these studies were interventional and 2 were observational trials. Meta-analysis of the observational trials (N = 851), both of which were retrospective cohort studies, showed significant improvement in the primary outcome (i.e., cure rate) with adjunctive lithium (odds ratio [OR], 1.92; 95% confidence interval [CI], 1.24 to 2.96). The combined interventional trials (N = 485) also showed an improvement in cure rate, but the difference did not reach statistical significance (OR, 1.28; 95% CI, 0.85 to 1.91). Adjunctive lithium reduced time to cure and blunted thyroid hormone excursions after RAI. Lithium-related side effects were infrequent and usually mild. The observational trials demonstrated significant improvement in the cure rate of hyperthyroidism when lithium is added to RAI. The improvements shown in the interventional trials did not reach statistical significance due to the effect of a single, large negative trial.
Light energy attenuation through orthodontic ceramic brackets at different irradiation times.
Santini, Ario; Tiu, Szu Hui; McGuinness, Niall J P; Aldossary, Mohammed Saeed
2016-09-01
To evaluate the total light energy (TLE) transmission through three types of ceramic brackets with, bracket alone and with the addition of orthodontic adhesive, at different exposure durations, and to compare the microhardness of the cured adhesive. Three different makes of ceramic brackets, Pure Sapphire(M), Clarity™ ADVANCED(P) and Dual Ceramic(P) were used. Eighteen specimens of each make were prepared and allocated to three groups (n = 6). MARC(®)-resin calibrator was used to determine the light curing unit (LCU) tip irradiance (mW/cm(2)) and TLE (J/cm(2)) transmitted through the ceramic brackets, and through ceramic bracket plus Transbond™ XT Light Cure Adhesive, for 5, 10 and 20 s. Vickers-hardness values at the bottom of the cured adhesive were determined. Statistical analysis used one-way analysis of variance (ANOVA); P = 0.05. TLE transmission rose significantly among all samples with increasing exposure durations. TLE reaching the adhesive- enamel interface was less than 10 J/cm(2), and through monocrystalline and polycrystalline ceramic brackets was significantly different (P < 0.05). Pure Sapphire(M) showed the highest amount of TLE transmission and Vickers-hardness values for 5, 10 and 20 s. Following manufacturer's recommendations, insufficient TLE may be delivered to the adhesive: increasing the exposure durations may be required when adhesive is cured through ceramic brackets. Clinicians are advised to measure the tip irradiance of their LCUs and increase curing time beyond 5 s. Orthodontic clinicians should understand the type of light curing device and the orthodontic adhesive used in their practice.
Development of a fast curing tissue adhesive for meniscus tear repair.
Bochyńska, Agnieszka Izabela; Hannink, Gerjon; Janssen, Dennis; Buma, Pieter; Grijpma, Dirk W
2017-01-01
Isocyanate-terminated adhesive amphiphilic block copolymers are attractive materials to treat meniscus tears due to their tuneable mechanical properties and good adhesive characteristics. However, a drawback of this class of materials is their relatively long curing time. In this study, we evaluate the use of an amine cross-linker and addition of catalysts as two strategies to accelerate the curing rates of a recently developed biodegradable reactive isocyanate-terminated hyper-branched adhesive block copolymer prepared from polyethylene glycol (PEG), trimethylene carbonate, citric acid and hexamethylene diisocyanate. The curing kinetics of the hyper-branched adhesive alone and in combination with different concentrations of spermidine solutions, and after addition of 2,2-dimorpholinodiethylether (DMDEE) or 1,4-diazabicyclo [2.2.2] octane (DABCO) were determined using FTIR. Additionally, lap-shear adhesion tests using all compositions at various time points were performed. The two most promising compositions of the fast curing adhesives were evaluated in a meniscus bucket handle lesion model and their performance was compared with that of fibrin glue. The results showed that addition of both spermidine and catalysts to the adhesive copolymer can accelerate the curing rate and that firm adhesion can already be achieved after 2 h. The adhesive strength to meniscus tissue of 3.2-3.7 N was considerably higher for the newly developed compositions than for fibrin glue (0.3 N). The proposed combination of an adhesive component and a cross-linking component or catalyst is a promising way to accelerate curing rates of isocyanate-terminated tissue adhesives.
Khode, Rajiv Tarachand; Shenoi, Pratima Ramakrishna; Kubde, Rajesh R; Makade, Chetana S; Wadekar, Kanchan D; Khode, Priyanka Tarachand
2017-01-01
This study evaluated effect of infection control barriers on light intensity (LI) of light-curing unit (LCU) and microhardness of composite. Four different disposable barriers ( n = 30) were tested against the control. LI for each barrier was measured with Lux meter. One hundred and fifty Teflon molds were equally divided into five groups of thirty each. Composite was filled in bulk in these molds and cured without and with barrier. Microhardness was evaluated on top and bottom surface of composite specimen with microhardness testing machine and hardness ratio (HR) was derived. One-way analysis of variance, Tukey's honestly significant difference test, and paired t -test using SPSS version 18 software. All barriers had significantly reduced the baseline LI of LCU ( P < 0.0001), but only Cure Elastic Steri-Shield and latex cut glove pieces (LCGP) significantly reduced the microhardness of the composite ( P < 0.05). However, HR determined inadequate curing only with LCGP. Although entire tested barrier significantly reduced the LI; none, except LCGP markedly affected the degree of cure of the composite.
Cilla, Irene; Martínez, Luis; Beltrán, José Antonio; Roncalés, Pedro
2006-05-01
The effect of storage on dry-cured ham quality was studied. Sixteen vacuum-packaged boneless dry-cured hams and sixteen vacuum-packaged dry-cured ham cuts were stored in darkness under refrigeration (4±2°C; 8 months) or freezing (-18±1°C; 24 months), respectively. Instrumental colour and texture, physico-chemical and biochemical parameters, sensory profile and consumer acceptability and purchase satisfaction were measured throughout storage. The overall quality of refrigerated boneless dry-cured hams and frozen dry-cured ham cuts showed only limited changes throughout long-term storage. Significant changes involved loss of odour and flavour, increased adhesiveness and modification of hardness, the Semimembranosus muscle became tender while Biceps femoris became harder, leading to a higher textural homogeneity. In agreement with those changes, the overall acceptability assessed by a trained panel decreased throughout storage, though this was significant regarding only frozen hams. However, consumer evaluation of acceptability, as well as satisfaction with hypothetical purchasing, did not vary significantly throughout storage.
Multiple imputation of missing covariates for the Cox proportional hazards cure model
Beesley, Lauren J; Bartlett, Jonathan W; Wolf, Gregory T; Taylor, Jeremy M G
2016-01-01
We explore several approaches for imputing partially observed covariates when the outcome of interest is a censored event time and when there is an underlying subset of the population that will never experience the event of interest. We call these subjects “cured,” and we consider the case where the data are modeled using a Cox proportional hazards (CPH) mixture cure model. We study covariate imputation approaches using fully conditional specification (FCS). We derive the exact conditional distribution and suggest a sampling scheme for imputing partially observed covariates in the CPH cure model setting. We also propose several approximations to the exact distribution that are simpler and more convenient to use for imputation. A simulation study demonstrates that the proposed imputation approaches outperform existing imputation approaches for survival data without a cure fraction in terms of bias in estimating CPH cure model parameters. We apply our multiple imputation techniques to a study of patients with head and neck cancer. PMID:27439726
Eloranta, Sandra; Lambert, Paul C; Andersson, Therese M-L; Björkholm, Magnus; Dickman, Paul W
2014-09-01
Quantifying cancer patient survival from the perspective of cure is clinically relevant. However, most cure models estimate cure assuming no competing causes of death. We use a relative survival framework to demonstrate how flexible parametric cure models can be used in combination with competing-risks theory to incorporate noncancer deaths. Under a model that incorporates statistical cure, we present the probabilities that cancer patients (1) have died from their cancer, (2) have died from other causes, (3) will eventually die from their cancer, or (4) will eventually die from other causes, all as a function of time since diagnosis. We further demonstrate how conditional probabilities can be used to update the prognosis among survivors (eg, at 1 or 5 years after diagnosis) by summarizing the proportion of patients who will not die from their cancer. The proposed method is applied to Swedish population-based data for persons diagnosed with melanoma, colon cancer, or acute myeloid leukemia between 1973 and 2007.
Studies on chemoviscosity modeling for thermosetting resins
NASA Technical Reports Server (NTRS)
Bai, J. M.; Hou, T. H.; Tiwari, S. N.
1987-01-01
A new analytical model for simulating chemoviscosity of thermosetting resins has been formulated. The model is developed by modifying the well-established Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By introducing a relationship between the glass transition temperature Tg(t) and the degree of cure alpha(t) of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature dependent functions of the modified WLF theory constants C sub 1 (t) and C sub 2 (t) were determined from the isothermal cure data. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data. This work represents progress toward establishing a chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformation of the thermosetting resin systems during cure.
Chemoviscosity modeling for thermosetting resin systems, part 3
NASA Technical Reports Server (NTRS)
Hou, T. H.; Bai, J. M.
1988-01-01
A new analytical model for simulating chemoviscosity resin has been formulated. The model is developed by modifying the well established Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By introducing a relationship between the glass transition temperature (T sub g (t)) and the degree of cure alpha(t) of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature-dependent functions of the modified WLF theory parameters C sub 1 (T) and C sub 2 (T) were determined from the isothermal cure data. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data. This work represents a progress toward establishing a chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformations of the thermosetting resin systems during cure.
Electronic nose for the identification of pig feeding and ripening time in Iberian hams.
Santos, J P; García, M; Aleixandre, M; Horrillo, M C; Gutiérrez, J; Sayago, I; Fernández, M J; Arés, L
2004-03-01
An electronic nose system to control the processing of dry-cured Iberian ham is presented. The sensors involved are tin oxide semiconductors thin films. They were prepared by RF sputtering. Some of the sensors were doped with metal catalysts as Pt and Pd, in order to improve the selectivity of the sensors. The multisensor with 16 semiconductor sensors, gave different responses from two types of dry-cured Iberian hams which differ in the feeding and curing time. The data has been analysed using the PCA (principal component analysis) and backpropagation and probabilistic neural networks. The analysis shows that different types of Iberian ham can be discriminated and identified successfully.
NASA Technical Reports Server (NTRS)
Pearce, E.; Lin, S. C.
1981-01-01
The effects of resin composition, curing conditions fillers, and flame retardant additives on the flammability of diglycidyl ether of bisphenol-A (DGEBA) as measured by the oxygen index is examined. The oxygen index of DGEBA cured with various curing agents was between 0.198 to 0.238. Fillers and flame retardant additives can increase the oxygen index dependent on the material and the amount used. Changes in the basic cured resin properties can be anticipated with the addition of noncompatible additives. High flame resistant epoxy resins with good stability and mechanical properties are investigated.
Qualitative Beam Profiling of Light Curing Units for Resin Based Composites.
Haenel, Thomas; Hausnerová, Berenika; Steinhaus, Johannes; Moeginger, Ing Bernhard
2016-12-01
This study investigates two technically simple methods to determine the irradiance distribution of light curing units that governs the performance of a visible-light curing resin-based composites. Insufficient light irradiation leads to under-cured composites with poor mechanical properties and elution of residual monomers. The unknown irradiance distribution and its effect on the final restoration are the main critical issues requiring highly sophisticated experimental equipment. The study shows that irradiance distributions of LCUs can easily be determined qualitatively with generally available equipment. This significantly helps dentists in practices to be informed about the homogeneity of the curing lights. Copyright© 2016 Dennis Barber Ltd.
Effect of light curing units on the polymerization of bulk fill resin-based composites.
Shimokawa, Carlos Alberto Kenji; Turbino, Míriam Lacalle; Giannini, Marcelo; Braga, Roberto Ruggiero; Price, Richard Bengt
2018-05-22
To determine the potential effect of four different light curing units (LCUs) on the curing profile of two bulk fill resin-based composites (RBCs). Four LCUs (Bluephase 20i, Celalux 3, Elipar DeepCure-S and Valo Grand) were used to light cure two RBCs (Filtek Bulk Fill Posterior Restorative and Tetric EvoCeram Bulk Fill). The effective tip diameter, radiant power, radiant emittance, emission spectrum and light beam profile of the LCUs were measured. Knoop microhardness was measured at the top and bottom surfaces of RBC specimens that were 12-mm in diameter and 4-mm deep (n=5). The distribution of the spectral radiant power that was delivered to the surface of the specimen and the light transmission through the 4-mm thick specimens was measured using an integrating sphere. Two-way ANOVA and Tukey tests (α=0.05) were applied. The Valo Grand produced the most homogeneous microhardness across the surfaces of the RBCs (p>0.05). When the Celalux 3, Bluephase 20i and Elipar DeepCure-S lights were used, the center of the specimens achieved greater hardness values compared to their outer regions (p<0.05). Approximately 10% of the radiant power delivered to the top reached the bottom of the specimen, although almost no violet light passed through 4mm of either RBC. A positive correlation was observed between the radiant exposure and microhardness. The characteristics of the LCUs influenced the photoactivation of the RBCs. The use of a wide tip with a homogeneous light distribution is preferred when light curing RBCs using a bulk curing technique. Copyright © 2018. Published by Elsevier Inc.
Luyten, Jeroen; Kessels, Roselinde; Goos, Peter; Beutels, Philippe
2015-03-01
Setting fair health care priorities counts among the most difficult ethical challenges our societies are facing. To elicit through a discrete choice experiment the Belgian adult population's (18-75 years; N = 750) preferences for prioritizing health care and investigate whether these preferences are different for prevention versus cure. We used a Bayesian D-efficient design with partial profiles, which enables considering a large number of attributes and interaction effects. We included the following attributes: 1) type of intervention (cure vs. prevention), 2) effectiveness, 3) risk of adverse effects, 4) severity of illness, 5) link between the illness and patient's health-related lifestyle, 6) time span between intervention and effect, and 7) patient's age group. All attributes were statistically significant contributors to the social value of a health care program, with patient's lifestyle and age being the most influential ones. Interaction effects were found, showing that prevention was preferred to cure for disease in young adults, as well as for severe and lethal disease in people of any age. However, substantial differences were found in the preferences of respondents from different age groups, with different lifestyles and different health states. Our study suggests that according to the Belgian public, contextual factors of health gains such as patient's age and health-related lifestyle should be considered in priority setting decisions. The studies, however, revealed substantial disagreement in opinion between different population subgroups. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Yun Hae; Han, Joong Won; Kim, Don Won; Choi, Byung Keun; Murakami, R.
Delamination can be observed in the sound areas during and/or after a couple times exposure to the elevated curing temperature due to the repeated repair condition. This study was conducted for checking the degree of degradation of properties of the cured parts and delamination between skin prepreg and honeycomb core. Specimens with glass honeycomb sandwich construction and glass/epoxy prepreg were prepared. The specimens were cured 1 to 5 times at 260°F in an autoclave and each additionally exposed 50, 100 and 150 hours in the 260°F oven. Each specimen was tested for tensile strength, compressive strength, flatwise tensile strength and interlaminar shear strength. To monitor the characteristics of the resin itself, the cured resin was tested using DMA and DSC. As a results, the decrease of Tg value were observed in the specific specimen which is exposed over 50 hrs at 260°F. This means the change or degradative of resin properties is also related to the decrease of flatwise tensile properties. Accordingly, minimal exposure on the curing temperature is recommended for parts in order to prevent the delation and maintain the better condition.
Chemoviscosity modeling for thermosetting resins - I
NASA Technical Reports Server (NTRS)
Hou, T. H.
1984-01-01
A new analytical model for chemoviscosity variation during cure of thermosetting resins was developed. This model is derived by modifying the widely used WLF (Williams-Landel-Ferry) Theory in polymer rheology. Major assumptions involved are that the rate of reaction is diffusion controlled and is linearly inversely proportional to the viscosity of the medium over the entire cure cycle. The resultant first order nonlinear differential equation is solved numerically, and the model predictions compare favorably with experimental data of EPON 828/Agent U obtained on a Rheometrics System 4 Rheometer. The model describes chemoviscosity up to a range of six orders of magnitude under isothermal curing conditions. The extremely non-linear chemoviscosity profile for a dynamic heating cure cycle is predicted as well. The model is also shown to predict changes of glass transition temperature for the thermosetting resin during cure. The physical significance of this prediction is unclear at the present time, however, and further research is required. From the chemoviscosity simulation point of view, the technique of establishing an analytical model as described here is easily applied to any thermosetting resin. The model thus obtained is used in real-time process controls for fabricating composite materials.
NASA Astrophysics Data System (ADS)
Shoushtari Zadeh Naseri, Aida; Jalali-Arani, Azam
2015-10-01
Rubber blends based on (styrene-butadiene rubber (SBR)/ethylene-propylene-diene monomer (EPDM)) with and without organoclay (OC) were prepared through a melt mixing process. The concentration ratio of the rubber phases (EPDM/SBR; 50/50 wt%) and the amount of the OC were kept constant. The samples were then vulcanized by means of gamma radiation using a Co-60 gamma source as well as sulfur cure system. The effect of absorbed dose on the formation of the crosslinks was confirmed by the Fourier transform infrared spectroscopy (FTIR). The effects of absorbed dose, sulfur cure system and OC on the gel content, and crosslink density were evaluated by the chemical tests. Applying the Charlesby-Pinner equation to estimate the radiation chemical yield, revealed that the use of OC in the blend caused 20% reduction in the degradation/crosslinking ratio. Employing the swelling test data, some thermodynamic parameters were determined. Using field emission scanning electron microscopy (FE-SEM) to investigate microstructure of the samples revealed a more homogeneous structure and also an increase in compatibility of the blend components in the sample cured by the irradiation in comparison to that cured by the sulfur curing system.
Effect of light energy density on conversion degree and hardness of dual-cured resin cement.
Komori, Paula Carolina de Paiva; de Paula, Andréia Bolzan; Martin, Airton Abrāo; Tango, Rubens Nisie; Sinhoreti, Mario Alexandre Coelho; Correr-Sobrinho, Lourenço
2010-01-01
This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm x 5 mm) and covered with a Mylar strip. The tip of the light-curing unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37 degrees C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (alpha = 0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the light-curing unit and by its light energy density.
Chism, Grady W.; Vaughan, Martin A.; Muralidharan, Pooja; Marrs, Jim A.
2016-01-01
Abstract A course-based undergraduate research experience (CURE) spanning three semesters was introduced into freshman and sophomore biology classes, with the hypothesis that participation in a CURE affects skills in research, communication, and collaboration, which may help students persist in science. Student research projects were centered on the hypothesis that nicotine and caffeine exposure during early development affects gastrulation and heart development in zebrafish. First, freshmen generated original data showing distinct effects of embryonic nicotine and caffeine exposure on zebrafish heart development and function. Next, Cell Biology laboratory students continued the CURE studies and identified novel teratogenic effects of nicotine and caffeine during gastrulation. Finally, new freshmen continued the CURE research, examining additional toxicant effects on development. Students designed new protocols, made measurements, presented results, and generated high-quality preliminary data that were studied in successive semesters. By implementing this project, the CURE extended faculty research and provided a scalable model to address national goals to involve more undergraduates in authentic scientific research. In addition, student survey results support the hypothesis that CUREs provide significant gains in student ability to (1) design experiments, (2) analyze data, and (3) make scientific presentations, translating into high student satisfaction and enhanced learning. PMID:26829498
Jafarzadeh-Kashi, Tahereh Sadat; Erfan, Mohmmad; Kalbasi, Salmeh; Ghadiri, Malihe; Rakhshan, Vahid
2014-10-01
Polymerization of bonding agents (BA) is a critical factor in determining the success of bonded restorations. We aimed to assess the effects of two light curing units and two temperatures on the extent of polymerization (EP) of a commercial BA and an experimental BA. Forty BA specimens were randomly divided into 8 subgroups of n = 5 to compare the polymerization of two BAs (experimental/Scotchbond) based on the variables: temperature (23/37 °C) and light-curing unit (quartz-tungsten-halogen/light-emitting diode). The EP (%) was measured using differential scanning calorimetry, and analyzed using the t-test, two- and three-way analyses of variance (ANOVA), and the Bonferroni test (α = 0.05). There were significant differences between the EP results between the two BAs (P = 0.012) and due to the different temperatures (P = 0.001), but not between the different light-curing units (P = 0.548). The interaction between BA and temperature was significant (P < 0.001). The other interactions were nonsignificant. The two light-curing units had similar effects on the EP. The EP values were better when curing was performed at human body temperature.
Sarmah, Swapnalee; Chism, Grady W; Vaughan, Martin A; Muralidharan, Pooja; Marrs, Jim A; Marrs, Kathleen A
2016-08-01
A course-based undergraduate research experience (CURE) spanning three semesters was introduced into freshman and sophomore biology classes, with the hypothesis that participation in a CURE affects skills in research, communication, and collaboration, which may help students persist in science. Student research projects were centered on the hypothesis that nicotine and caffeine exposure during early development affects gastrulation and heart development in zebrafish. First, freshmen generated original data showing distinct effects of embryonic nicotine and caffeine exposure on zebrafish heart development and function. Next, Cell Biology laboratory students continued the CURE studies and identified novel teratogenic effects of nicotine and caffeine during gastrulation. Finally, new freshmen continued the CURE research, examining additional toxicant effects on development. Students designed new protocols, made measurements, presented results, and generated high-quality preliminary data that were studied in successive semesters. By implementing this project, the CURE extended faculty research and provided a scalable model to address national goals to involve more undergraduates in authentic scientific research. In addition, student survey results support the hypothesis that CUREs provide significant gains in student ability to (1) design experiments, (2) analyze data, and (3) make scientific presentations, translating into high student satisfaction and enhanced learning.
Asano, Junichi; Hirakawa, Akihiro; Hamada, Chikuma; Yonemori, Kan; Hirata, Taizo; Shimizu, Chikako; Tamura, Kenji; Fujiwara, Yasuhiro
2013-01-01
In prognostic studies for breast cancer patients treated with neoadjuvant chemotherapy (NAC), the ordinary Cox proportional-hazards (PH) model has been often used to identify prognostic factors for disease-free survival (DFS). This model assumes that all patients eventually experience relapse or death. However, a subset of NAC-treated breast cancer patients never experience these events during long-term follow-up (>10 years) and may be considered clinically "cured." Clinical factors associated with cure have not been studied adequately. Because the ordinary Cox PH model cannot be used to identify such clinical factors, we used the Cox PH cure model, a recently developed statistical method. This model includes both a logistic regression component for the cure rate and a Cox regression component for the hazard for uncured patients. The purpose of this study was to identify the clinical factors associated with cure and the variables associated with the time to recurrence or death in NAC-treated breast cancer patients without a pathologic complete response, by using the Cox PH cure model. We found that hormone receptor status, clinical response, human epidermal growth factor receptor 2 status, histological grade, and the number of lymph node metastases were associated with cure.
Shack, L G; Shah, A; Lambert, P C; Rachet, B
2012-12-01
Stage and age at diagnosis are important prognostic factors for patients with colorectal cancer. However, the proportion cured by stage and age is unknown in England. This population-based study includes 29,563 adult patients who were diagnosed and registered with colorectal cancer during 1997-2004 and followed till 2007 in North West England. Multiple imputation was used to provide more reliable estimates of stage at diagnosis, when these data were missing. Cure mixture models were used to estimate the proportion 'cured' and the median survival of the uncured by age and stage. For both colon and rectal cancer the proportion of patients cured and median survival time of the uncured decreased with advancing stage and increasing age. Patients aged under 65 years had the highest proportion cured and longest median survival of the uncured. Cure of colorectal cancer patients is dependent on stage and age at diagnosis with younger patients or those with less advanced disease having a better prognosis. Further efforts are required, in order to reduce the proportion of patients presenting with stage III and IV disease and ultimately increase the chance of cure. Copyright © 2012 Elsevier Ltd. All rights reserved.
Fight fire with fire: Gene therapy strategies to cure HIV.
Huyghe, Jon; Magdalena, Sips; Vandekerckhove, Linos
2017-08-01
Human Immunodeficiency Virus (HIV) to date remains one of the most notorious viruses mankind has ever faced. Despite enormous investments in HIV research for more than 30 years an effective cure for HIV has been elusive. Areas covered: Combination antiretroviral therapy (cART) suppresses active viral replication, but is not able to eliminate the virus completely due to stable integration of HIV inside the host genome of infected cells and the establishment of a latent reservoir, that is insensitive to cART. Nevertheless, this latent HIV reservoir is fully capable to refuel viral replication when treatment is stopped, creating a major obstacle towards a cure for HIV. Several gene therapy approaches ranging from the generation of HIV resistant CD4 + T cells to the eradication of HIV infected cells by immune cell engineering are currently under pre-clinical and clinical investigation and may present a promising road to a cure. In this review, we focus on the status and the prospects of gene therapy strategies to cure/eradicate HIV. Expert commentary: Recent advances in gene therapy for oncology and infectious diseases indicate that gene therapy may be a feasible and very potent cure strategy, and therefore a potential game changer in the search for an effective HIV cure.
Hodson, Nicholas A; Dunne, Stephen M; Pankhurst, Caroline L
2005-04-01
Dental curing lights are vulnerable to contamination with oral fluids during routine intra-oral use. This controlled study aimed to evaluate whether or not disposable transparent barriers placed over the light-guide tip would affect light output intensity or the subsequent depth of cure of a composite restoration. The impact on light intensity emitted from high-, medium- and low-output light-cure units in the presence of two commercially available disposable infection-control barriers was evaluated against a no-barrier control. Power density measurements from the three intensity light-cure units were recorded with a radiometer, then converted to a digital image using an intra-oral camera and values determined using a commercial computer program. For each curing unit, the measurements were repeated on ten separate occasions with each barrier and the control. Depth of cure was evaluated using a scrape test in a natural tooth model. At each level of light output, the two disposable barriers produced a significant reduction in the mean power density readings compared to the no-barrier control (P<0.005). The cure sleeve inhibited light output to a greater extent than either the cling film or the control (P<0.005). Only composite restorations light-activated by the high level unit demonstrated a small but significant decrease in the depth of cure compared to the control (P<0.05). Placing disposable barriers over the light-guide tip reduced the light intensity from all three curing lights. There was no impact on depth of cure except for the high-output light, where a small decrease in cure depth was noted but this was not considered clinically significant. Disposable barriers can be recommended for use with light-cure lights.
Laser biostimulation in treatment of actinomycosis
NASA Astrophysics Data System (ADS)
Grzesiak-Janas, Grazyna; Janas, Anna
2003-10-01
Biostimulative laser therapy was used in 4 patients with actinomycosis. In each patient extraoral radiation by means of the "contact point" method was applied. The results were evaluated on the basis of clinical and bacteriological examinations. Laserotherapy had a beneficial effect on the course of treatment of actinomycosis and shortened the time of curing.
Corwin, Lisa A; Runyon, Christopher R; Ghanem, Eman; Sandy, Moriah; Clark, Greg; Palmer, Gregory C; Reichler, Stuart; Rodenbusch, Stacia E; Dolan, Erin L
2018-06-01
Course-based undergraduate research experiences (CUREs) provide a promising avenue to attract a larger and more diverse group of students into research careers. CUREs are thought to be distinctive in offering students opportunities to make discoveries, collaborate, engage in iterative work, and develop a sense of ownership of their lab course work. Yet how these elements affect students' intentions to pursue research-related careers remain unexplored. To address this knowledge gap, we collected data on three design features thought to be distinctive of CUREs (discovery, iteration, collaboration) and on students' levels of ownership and career intentions from ∼800 undergraduates who had completed CURE or inquiry courses, including courses from the Freshman Research Initiative (FRI), which has a demonstrated positive effect on student retention in college and in science, technology, engineering, and mathematics. We used structural equation modeling to test relationships among the design features and student ownership and career intentions. We found that discovery, iteration, and collaboration had small but significant effects on students' intentions; these effects were fully mediated by student ownership. Students in FRI courses reported significantly higher levels of discovery, iteration, and ownership than students in other CUREs. FRI research courses alone had a significant effect on students' career intentions.
B-Cure Laser Dental Pro technology for prevention and treatment of peri-implant mucositis
NASA Astrophysics Data System (ADS)
Gileva, O. S.; Libik, T. V.; Chuprakov, M. A.; Yakov, A. Y.; Mirsaeva, F. Z.
2017-09-01
Oral mucositis (OM) is the severe inflammation, lesioning and ulceration of the epithelia, accompanied by bleeding and intensive pain. OM is a common complication of dental implantation. Low-level laser therapy (LLLT) has been found to enhance the repair and healing of epithelia. The aim of this study was to evaluate the effectiveness of preventive and treatment use of LLLT (B-Cure Laser Dental Pro technology in original author's techniques) in the patients who have undergone dental implantation. Simple blind randomized prospective one-center comparative placebo-controlled clinical trial is carried out on the group of 30 partially edentulous patients. It is proved that the use of LLLT before and after installation of dental implants provides: 1) reliable reduction (by 3.5 times) of the frequency of implication and intensity of pain in the first days after operation; 2) reduction (by 3.3-3.7 times) of frequency, duration and intensity of local edematous and inflammatory processes in peri-implant zone and facial soft tissue edema; 3) effective prophylaxis of postoperative sensory, paresthesia and neurologic disturbances in maxillofacial area.
Modeling the filament winding process
NASA Technical Reports Server (NTRS)
Calius, E. P.; Springer, G. S.
1985-01-01
A model is presented which can be used to determine the appropriate values of the process variables for filament winding a cylinder. The model provides the cylinder temperature, viscosity, degree of cure, fiber position and fiber tension as functions of position and time during the filament winding and subsequent cure, and the residual stresses and strains within the cylinder during and after the cure. A computer code was developed to obtain quantitative results. Sample results are given which illustrate the information that can be generated with this code.
A combinaison of UV curing technology with ATL process
NASA Astrophysics Data System (ADS)
Balbzioui, I.; Hasiaoui, B.; Barbier, G.; L'hostis, G.; Laurent, F.; Ibrahim, A.; Durand, B.
2017-10-01
In order to reduce the time and the cost of manufacturing composite, UV curing technology combined with automated tape placement process (ATL) based on reverse approach by working with a fixed head was studied in this article. First, a brief description of the developed head placement is presented. Mechanical properties are then evaluated by varying process parameters, including compaction force and tape placement speed. Finally, a parametric study is carried out to identify suitable materials and process parameters to manufacture a photo composite material with high mechanical performances. The obtained results show that UV curing is a very good alternative for thermal polymerization because of its fast cure speed due to less dependency on temperature.
Fuentes, Verónica; Ventanas, Jesús; Morcuende, David; Estévez, Mario; Ventanas, Sonia
2010-07-01
The effect of HHP treatment (600 MPa) on the oxidative stability of lipids and proteins of vacuum-packaged Iberian dry-cured ham and the impact on the sensory characteristics of the product was investigated. In order to assess how different commercial presentations are affected by HHP treatment, three different presentations of vacuum-packaged Iberian dry-cured ham were considered, namely, (i) intact format (IF) corresponding to non-sliced vacuum-packaged dry-cured ham, (ii) conventional-sliced format (CSF) corresponding to dry-cured ham slices placed stretched out in the package and (iii) alternative-sliced format (ASF) corresponding to dry-cured ham slices piled up horizontally. The oxidation of dry-cured ham lipids and proteins was enhanced by HHP-treatment with the presentation being highly influential on these oxidative reactions. Pre-slicing dry-cured ham results in a more susceptible product to oxidative reactions during pressurisation and subsequent refrigerated storage. Possible mechanisms, by which HHP-induced oxidative reactions would affect particular sensory traits in vacuum-packaged Iberian dry-cured ham such as colour, texture and flavour attributes, are discussed. Copyright 2010 Elsevier Ltd. All rights reserved.
High-frequency and hot-platen curing of medium-density fiberboards
Robert R. Stevens; George E. Woodson
1977-01-01
The effects of two curing methods-high-frequencey heating and hot-platen heating-on the properties of a ureaformaldehyde-bonded medium-density fiberboard prepared with a southern-hardwoods furnish (50% southern read oak, 25% mockernut hickory, and 25% sweetgum) were studied. Boards of three densities-38, 44, and 50 lb./ft3-were cured by the two...
Computational study on UV curing characteristics in nanoimprint lithography: Stochastic simulation
NASA Astrophysics Data System (ADS)
Koyama, Masanori; Shirai, Masamitsu; Kawata, Hiroaki; Hirai, Yoshihiko; Yasuda, Masaaki
2017-06-01
A computational simulation model of UV curing in nanoimprint lithography based on a simplified stochastic approach is proposed. The activated unit reacts with a randomly selected monomer within a critical reaction radius. Cluster units are chained to each other. Then, another monomer is activated and the next chain reaction occurs. This process is repeated until a virgin monomer disappears within the reaction radius or until the activated monomers react with each other. The simulation model well describes the basic UV curing characteristics, such as the molecular weight distributions of the reacted monomers and the effect of the initiator concentration on the conversion ratio. The effects of film thickness on UV curing characteristics are also studied by the simulation.
Prevolnik, M; Andronikov, D; Žlender, B; Font-i-Furnols, M; Novič, M; Škorjanc, D; Čandek-Potokar, M
2014-01-01
An attempt to classify dry-cured hams according to the maturation time on the basis of near infrared (NIR) spectra was studied. The study comprised 128 samples of biceps femoris (BF) muscle from dry-cured hams matured for 10 (n=32), 12 (n=32), 14 (n=32) or 16 months (n=32). Samples were minced and scanned in the wavelength range from 400 to 2500 nm using spectrometer NIR System model 6500 (Silver Spring, MD, USA). Spectral data were used for i) splitting of samples into the training and test set using 2D Kohonen artificial neural networks (ANN) and for ii) construction of classification models using counter-propagation ANN (CP-ANN). Different models were tested, and the one selected was based on the lowest percentage of misclassified test samples (external validation). Overall correctness of the classification was 79.7%, which demonstrates practical relevance of using NIR spectroscopy and ANN for dry-cured ham processing control. Copyright © 2013 Elsevier Ltd. All rights reserved.
Khandaker, Morshed; Vaughan, Melville B; Morris, Tracy L; White, Jeremiah J; Meng, Zhaotong
2014-01-01
The most common bone cement material used clinically today for orthopedic surgery is poly(methyl methacrylate) (PMMA). Conventional PMMA bone cement has several mechanical, thermal, and biological disadvantages. To overcome these problems, researchers have investigated combinations of PMMA bone cement and several bioactive particles (micrometers to nanometers in size), such as magnesium oxide, hydroxyapatite, chitosan, barium sulfate, and silica. A study comparing the effect of these individual additives on the mechanical, thermal, and cell functional properties of PMMA would be important to enable selection of suitable additives and design improved PMMA cement for orthopedic applications. Therefore, the goal of this study was to determine the effect of inclusion of magnesium oxide, hydroxyapatite, chitosan, barium sulfate, and silica additives in PMMA on the mechanical, thermal, and cell functional performance of PMMA. American Society for Testing and Materials standard three-point bend flexural and fracture tests were conducted to determine the flexural strength, flexural modulus, and fracture toughness of the different PMMA samples. A custom-made temperature measurement system was used to determine maximum curing temperature and the time needed for each PMMA sample to reach its maximum curing temperature. Osteoblast adhesion and proliferation experiments were performed to determine cell viability using the different PMMA cements. We found that flexural strength and fracture toughness were significantly greater for PMMA specimens that incorporated silica than for the other specimens. All additives prolonged the time taken to reach maximum curing temperature and significantly improved cell adhesion of the PMMA samples. The results of this study could be useful for improving the union of implant-PMMA or bone-PMMA interfaces by incorporating nanoparticles into PMMA cement for orthopedic and orthodontic applications. PMID:24920906
Khandaker, Morshed; Vaughan, Melville B; Morris, Tracy L; White, Jeremiah J; Meng, Zhaotong
2014-01-01
The most common bone cement material used clinically today for orthopedic surgery is poly(methyl methacrylate) (PMMA). Conventional PMMA bone cement has several mechanical, thermal, and biological disadvantages. To overcome these problems, researchers have investigated combinations of PMMA bone cement and several bioactive particles (micrometers to nanometers in size), such as magnesium oxide, hydroxyapatite, chitosan, barium sulfate, and silica. A study comparing the effect of these individual additives on the mechanical, thermal, and cell functional properties of PMMA would be important to enable selection of suitable additives and design improved PMMA cement for orthopedic applications. Therefore, the goal of this study was to determine the effect of inclusion of magnesium oxide, hydroxyapatite, chitosan, barium sulfate, and silica additives in PMMA on the mechanical, thermal, and cell functional performance of PMMA. American Society for Testing and Materials standard three-point bend flexural and fracture tests were conducted to determine the flexural strength, flexural modulus, and fracture toughness of the different PMMA samples. A custom-made temperature measurement system was used to determine maximum curing temperature and the time needed for each PMMA sample to reach its maximum curing temperature. Osteoblast adhesion and proliferation experiments were performed to determine cell viability using the different PMMA cements. We found that flexural strength and fracture toughness were significantly greater for PMMA specimens that incorporated silica than for the other specimens. All additives prolonged the time taken to reach maximum curing temperature and significantly improved cell adhesion of the PMMA samples. The results of this study could be useful for improving the union of implant-PMMA or bone-PMMA interfaces by incorporating nanoparticles into PMMA cement for orthopedic and orthodontic applications.
Simultaneous acoustic and dielectric real time curing monitoring of epoxy systems
NASA Astrophysics Data System (ADS)
Gkikas, G.; Saganas, Ch.; Grammatikos, S. A.; Aggelis, D. G.; Paipetis, A. S.
2012-04-01
The attainment of structural integrity of the reinforcing matrix in composite materials is of primary importance for the final properties of the composite structure. The detailed monitoring of the curing process on the other hand is paramount (i) in defining the optimal conditions for the impregnation of the reinforcement by the matrix (ii) in limiting the effects of the exotherm produced by the polymerization reaction which create unwanted thermal stresses and (iii) in securing optimal behavior in matrix controlled properties, such as off axis or shear properties and in general the durability of the composite. Dielectric curing monitoring is a well known technique for distinguishing between the different stages of the polymerization of a typical epoxy system. The technique successfully predicts the gelation and the vitrification of the epoxy and has been extended for the monitoring of prepregs. Recent work has shown that distinct changes in the properties of the propagated sound in the epoxy which undergoes polymerization is as well directly related to the gelation and vitrification of the resin, as well as to the attainment of the final properties of the resin system. In this work, a typical epoxy is simultaneously monitored using acoustic and dielectric methods. The system is isothermally cured in an oven to avoid effects from the polymerization exotherm. Typical broadband sensors are employed for the acoustic monitoring, while flat interdigital sensors are employed for the dielectric scans. All stages of the polymerization process were successfully monitored and the validity of both methods was cross checked and verified.
A Call to Develop Course-Based Undergraduate Research Experiences (CUREs) for Nonmajors Courses
Ballen, Cissy J.; Blum, Jessamina E.; Brownell, Sara; Hebert, Sadie; Hewlett, James; Klein, Joanna R.; McDonald, Erik A.; Monti, Denise L.; Nold, Stephen C.; Slemmons, Krista E.; Soneral, Paula A. G.; Cotner, Sehoya
2017-01-01
Course-based undergraduate research experiences (CUREs) for non–science majors (nonmajors) are potentially distinct from CUREs for developing scientists in their goals, learning objectives, and assessment strategies. While national calls to improve science, technology, engineering, and mathematics education have led to an increase in research revealing the positive effects of CUREs for science majors, less work has specifically examined whether nonmajors are impacted in the same way. To address this gap in our understanding, a working group focused on nonmajors CUREs was convened to discuss the following questions: 1) What are our laboratory-learning goals for nonmajors? 2) What are our research priorities to determine best practices for nonmajors CUREs? 3) How can we collaborate to define and disseminate best practices for nonmajors in CUREs? We defined three broad student outcomes of prime importance to the nonmajors CURE: improvement of scientific literacy skills, proscience attitudes, and evidence-based decision making. We evaluated the state of knowledge of best practices for nonmajors, and identified research priorities for the future. The report that follows is a summary of the conclusions and future directions from our discussion. PMID:28450449
Influence of Curing on the Strength Development of Calcium-Containing Geopolymer Mortar
Li, Xueying; Wang, Zheng; Jiao, Zhenzhen
2013-01-01
This paper investigated the curing effects on the mechanical properties of calcium-containing geopolymer mortar. Three precursors are used: Class C fly ash, Class F fly ash plus calcium hydroxide and Class F fly ash plus slag. Curing conditions included: (1) standard curing at 20 ± 3 °C and RH 95% (C); (2) steam curing at 60 °C for 24 h (S); (3) steam curing at 60 °C for 6 h (S6); and (4) oven curing at 60 °C for 24 h (O), then the latter three followed by the standard curing. Under the standard conditions, the flexural strength and compressive strength of Class C fly ash geopolymer mortars developed quickly until the age of 7 days, followed by a gradual increase. Specimens with Class F fly ash plus Ca(OH)2 showed slow increase till the age of 28 days. Under these non-standard conditions (2–4), all specimens showed higher 3-day strength, while later strengths were either higher or lower than those in standard conditions, depending on the type of the precursor. PMID:28788377
Influence of Curing on the Strength Development of Calcium-Containing Geopolymer Mortar.
Li, Xueying; Wang, Zheng; Jiao, Zhenzhen
2013-11-07
This paper investigated the curing effects on the mechanical properties of calcium-containing geopolymer mortar. Three precursors are used: Class C fly ash, Class F fly ash plus calcium hydroxide and Class F fly ash plus slag. Curing conditions included: (1) standard curing at 20 ± 3 °C and RH 95% (C); (2) steam curing at 60 °C for 24 h (S); (3) steam curing at 60 °C for 6 h (S6); and (4) oven curing at 60 °C for 24 h (O), then the latter three followed by the standard curing. Under the standard conditions, the flexural strength and compressive strength of Class C fly ash geopolymer mortars developed quickly until the age of 7 days, followed by a gradual increase. Specimens with Class F fly ash plus Ca(OH)₂ showed slow increase till the age of 28 days. Under these non-standard conditions (2-4), all specimens showed higher 3-day strength, while later strengths were either higher or lower than those in standard conditions, depending on the type of the precursor.
Effectiveness and safety of nitrofurantoin in outpatient male veterans.
Ingalsbe, Michelle L; Wojciechowski, Amy L; Smith, Kelly A; Mergenhagen, Kari A
2015-08-01
The aim of the study was to assess both the safety and the effectiveness of nitrofurantoin in male veterans treated for urinary tract infections (UTIs) with varying degrees of renal impairment in the outpatient setting. Nitrofurantoin is an important oral option for treating UTIs given increasing resistance to commonly used agents. Nitrofurantoin is currently contraindicated in patients with a creatinine clearance (CrCl) of < 60 ml/min, but the reason for this threshold has not been well documented. Data were collected through a retrospective chart review from January 2004 to July 2013 of men who had received nitrofurantoin. Bivariate analyses followed by multivariate analyses were performed between patients experiencing clinical cure and those who did not, to determine factors significantly impacting effectiveness. The Gram stain of the organism causing the UTI and CrCl were significant factors impacting effectiveness. For every 1 ml/min increase in CrCl, the odds of clinical cure increased by 1.3%. Patients with Gram-negative UTIs predictably had 80% cure rates with CrCl around 60 ml/min. Patients with Gram-positive UTIs required higher CrCl, nearing 100 ml/min, to establish an 80% cure rate. Adverse effects did not vary with CrCl. The odds of clinical cure varied with CrCl and with the type of organism causing the UTI, while adverse events did not differ based on renal function. A minimum CrCl of 60 ml/min is suggested for men to achieve an 80% cure rate for UTIs with the most common urinary pathogens.
Liu, Yanguo; Li, Hao; Zheng, Xia; Li, Xiao; Li, Jianfeng; Jiang, Guanchao
2015-01-01
Purpose: To investigate the association between intraoperative palm temperature change and the curative effect of sympathicotomy. Methods: 49 patients with palmar hyperhidrosis were treated with bilateral endoscopic sympathicotomy. Ipsilateral palm temperature was monitored before and at 3–5 min increments after the sympathetic trunk was transected. The maximum temperature elevation (Tmax) was calculated and used to evaluate the effect on postoperative cure rates. Results: Forty-nine patients underwent 98 sympathicotomies. There were 77 T4 sympathicotomies, 15 T4 + T5 sympathicotomies, and six T3 sympathicotomies due to pleural adhesions or neurovascular proximity. The Tmax was ≤1°C in 49 (50.0%), 1–1.5°C in 17 (17.3%), and >1.5°C in 32 (32.7%) palms. Ninety-two palms of 46 patients were followed with complete efficacy, and three patients were lost to follow up. Cure was achieved in 86 palms (93.4%). Of the 71 palms which underwent T4 sympathicotomy, cure was achieved in 67 palms (94.3%). In those palms which did not achieve cure, the Tmax was less than 1°C in each case, while in palms with a Tmax ≤1°C, 32 of 36 (88.9%) were cured. Conclusion: There is an association between intraoperative palmar temperature change and curative effect. However, palmar temperature change cannot be used to predict cure or guide surgical approach. PMID:26041256
Labruyère, Céline; Monteverde, Fabien; Alexandre, Michaël; Dubois, Philippe
2009-04-01
Poly(dimethylsiloxane) (PDMS)/montmorillonite (MMT) composites have been prepared using a newly synthesized omega-ammonium functionalized poly(dimethylsiloxane) compatibilizer coupled with a dispersion technique in water. The organoclay containing the new siloxane surfactant was characterized by TGA and XRD. For the first time, a nanoscopic dispersion of MMT nanoplatelets in the PDMS composite cured by hydrosilylation and a good compatibility between clay layers and matrix were obtained. The beneficial effect of both the surfactant and the water onto clay nanoplatelet dispersion was evaluated by different microscopy techniques and by measuring different properties such as the viscosity of the uncured PDMS/MMT nanodispersions, and the swelling rate and Young's modulus of the cured PDMS/MMT nanocomposites.
Secondary prevention fallacy: pitfalls in comparing with primary.
Caro, J J; Huybrechts, K F; Klittich, W S
2001-10-01
A basic tenet of our culture is the idea that preventing ills is better than curing them. This principle is entrenched in many proverbs and popular admonitions: 'A stitch in time saves nine', 'An ounce of prevention is worth a pound of cure'. These well-worn sayings crisply convey our sense that it is preferable to intervene before a bad event occurs than to wait and try to mitigate it afterwards. Yet, economic analyses have demonstrated that in healthcare this does not hold: 'primary prevention' does not provide as good value-for-money as 'secondary prevention'. Is this reversal of folk wisdom correct? Or, instead, is it a result of faults in the application of the relatively new methodology of cost-effectiveness analyses?
Problems encountered with conventional fiber-reinforced composites
NASA Technical Reports Server (NTRS)
Landel, R. F.
1981-01-01
Preparational, computational, and operational problems associated with fiber-reinforced composites (FRC) are reviewed. Initial preparation of FRCs is shown to involve consideration of the type of prepreg, the setting time, cure conditions and cycles, and cure temperatures. The effects of the choice of bonding agents, the fiber transfer length, and individual fiber responses to bonding agents are noted to have an impact on fiber strength, moisture uptake, and fatigue resistance. The deformation prior to failure and the failure region are modeled through models of mini-, micro- and macro mechanics formulations employing a stiffness matrix, failure criterion, or fracture mechanics. The detection, evaluation, and repair of defects comprises the operational domain, and it is stressed that no good repair techniques exist for FRCs.
Aging Effects of Environmentally-Friendly Cleaners on Adhesive Bond Integrity
NASA Technical Reports Server (NTRS)
Biegert, L. L.; Anderson, G. L.; Evans, K. B.; Olsen, B. D.; Weber, B. L.; McCool, A. A. (Technical Monitor)
2000-01-01
Because of the 1990 Clean Air Act Amendment many chlorinated solvents are being phased out of use in manufacturing industries. Replacement of the ODC (ozone- depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past nine years at Thiokol Propulsion, Cordant Technologies. Many of the non-ODC cleaners contain compounds that can potentially degrade over time under conditions of high temperature, humidity and exposure to light. The chemical composition of environmentally conditioned cleaners and the subsequent effect on aluminum/amine-cured epoxy bond integrity as measured by Tapered Double Cantilever Beam were evaluated. From this study it is observed that moisture content increases for those cleaners containing polar compounds. Non-volatile residue content increases as stabilizers are depleted and the chemical compound limonene is oxidized. A change in aluminum/ amine-cured epoxy bond fracture toughness is observed as some of these cleaners age with increases in moisture and NVR content.
Modeling the VARTM Composite Manufacturing Process
NASA Technical Reports Server (NTRS)
Song, Xiao-Lan; Loos, Alfred C.; Grimsley, Brian W.; Cano, Roberto J.; Hubert, Pascal
2004-01-01
A comprehensive simulation model of the Vacuum Assisted Resin Transfer Modeling (VARTM) composite manufacturing process has been developed. For isothermal resin infiltration, the model incorporates submodels which describe cure of the resin and changes in resin viscosity due to cure, resin flow through the reinforcement preform and distribution medium and compaction of the preform during the infiltration. The accuracy of the model was validated by measuring the flow patterns during resin infiltration of flat preforms. The modeling software was used to evaluate the effects of the distribution medium on resin infiltration of a flat preform. Different distribution medium configurations were examined using the model and the results were compared with data collected during resin infiltration of a carbon fabric preform. The results of the simulations show that the approach used to model the distribution medium can significantly effect the predicted resin infiltration times. Resin infiltration into the preform can be accurately predicted only when the distribution medium is modeled correctly.
Mechanical impedance measurements for improved cost-effective process monitoring
NASA Astrophysics Data System (ADS)
Clopet, Caroline R.; Pullen, Deborah A.; Badcock, Rodney A.; Ralph, Brian; Fernando, Gerard F.; Mahon, Steve W.
1999-06-01
The aerospace industry has seen a considerably growth in composite usage over the past ten years, especially with the development of cost effective manufacturing techniques such as Resin Transfer Molding and Resin Infusion under Flexible Tooling. The relatively high cost of raw material and conservative processing schedules has limited their growth further in non-aerospace technologies. In-situ process monitoring has been explored for some time as a means to improving the cost efficiency of manufacturing with dielectric spectroscopy and optical fiber sensors being the two primary techniques developed to date. A new emerging technique is discussed here making use of piezoelectric wafers with the ability to sense not only aspects of resin flow but also to detect the change in properties of the resin as it cures. Experimental investigations to date have shown a correlation between mechanical impedance measurements and the mechanical properties of cured epoxy systems with potential for full process monitoring.
Effect of laser immunotherapy and surgery on the treatment of mouse mammary tumors
NASA Astrophysics Data System (ADS)
Chen, Vivian A.; Le, Henry; Li, Xiaosong; Wolf, Roman F.; Ferguson, Halie; Sarkar, Akhee; Liu, Hong; Nordquist, Robert E.; Chen, Wei R.
2010-02-01
Laser immunotherapy using laser photothermal therapy and immunological stimulation could achieve tumor-specific immune responses, as indicated by our previous pre-clinical and preliminary clinical studies. To further study the effect of laser immunotherapy, we conducted an investigation combining laser immunotherapy and surgery. After laser immunotherapy, treated tumors were surgically removed at different time points. The survival rates of treated mice were compared among different groups. Furthermore, the cured mice were rechallenged to test the immunity induced by laser immunotherapy. Our results showed that the mice treated with surgical removal one week after laser immunotherapy had the highest survival rate (77%). When the tumors were removed immediately after laser immunotherapy treatment, the survival rate was 57%. Most cured mice withstood tumor rechallenges, indicating an induction of tumor immunity by laser immunotherapy. The differentiations between different surgery groups indicate that the treated tumors have contributed to the immunological responses of the hosts.
Erratum to: Application of addition-cured silicone denture relining materials to adjust mouthguards.
Fukasawa, Shintaro; Churei, Hiroshi; Chowdhury, Ruman Uddin; Shirako, Takahiro; Shahrin, Sharika; Shrestha, Abhishekhi; Wada, Takahiro; Uo, Motohiro; Takahashi, Hidekazu; Ueno, Toshiaki
2016-01-01
The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.
Stress and flow analyses of ultraviolet-curable resin during curing
NASA Astrophysics Data System (ADS)
Umezaki, Eisaku; Okano, Akira; Koyama, Hiroto
2014-06-01
The stress and flow generated in ultraviolet (UV)-curable resin during curing in molds were measured to investigate their relationship. The specimens were molds consisting of glass plates and acrylic bars, and UV-curable liquid resin. The specimens were illuminated from above with UV rays. Photoelastic and visual images were separately obtained at a constant time interval using cameras during curing. To help obtain the visual images, acrylic powder was mixed with the liquid resin. The stress was obtained from the photoelastic images by a digital photoelastic technique with phase stepping, and the flow was obtained from the visual images by a particle-tracking velocimetry technique. Results indicate that the stress generated in the UV-curable resin during curing depends on the degree of contact between the mold and the cured area of the resin, and is hardly related to the flow.
Accelerated production of dry cured hams.
Marriott, N G; Graham, P P; Shaffer, C K; Phelps, S K
1987-01-01
Ten uncured legs from the right side of the sampled pork carcasses (Study A) were vacuum tumbled with the cure adjuncts for 30 min (T) and 10 counterparts from the left side were tumbled 30 min, rested 30 min and tumbled an additional 30 min (TRT). Evaluations were conducted at 40 and 70 days after cure application for color, taste attributes, percentage moisture, percentage salt and NO(3)(-) and NO(2)(-) content. Study B was the same except that 18 legs were boned, tumbled and cured for 40, 56 and 70 days. The TRT samples (Study A) at 40 days sustained less color fading (P < 0.05) during cookery, but no differences (P > 0.05) existed among the uncooked hams. Increased cure time enhanced moisture loss and salt content (Study A) and color retention during cookery (Study B). The TRT samples had increased moisture loss and salt content (Study A). Copyright © 1987. Published by Elsevier Ltd.
Wald, Ellen R; Nash, David; Eickhoff, Jens
2009-07-01
The role of antibiotic therapy in managing acute bacterial sinusitis (ABS) in children is controversial. The purpose of this study was to determine the effectiveness of high-dose amoxicillin/potassium clavulanate in the treatment of children diagnosed with ABS. This was a randomized, double-blind, placebo-controlled study. Children 1 to 10 years of age with a clinical presentation compatible with ABS were eligible for participation. Patients were stratified according to age (<6 or >or=6 years) and clinical severity and randomly assigned to receive either amoxicillin (90 mg/kg) with potassium clavulanate (6.4 mg/kg) or placebo. A symptom survey was performed on days 0, 1, 2, 3, 5, 7, 10, 20, and 30. Patients were examined on day 14. Children's conditions were rated as cured, improved, or failed according to scoring rules. Two thousand one hundred thirty-five children with respiratory complaints were screened for enrollment; 139 (6.5%) had ABS. Fifty-eight patients were enrolled, and 56 were randomly assigned. The mean age was 66 +/- 30 months. Fifty (89%) patients presented with persistent symptoms, and 6 (11%) presented with nonpersistent symptoms. In 24 (43%) children, the illness was classified as mild, whereas in the remaining 32 (57%) children it was severe. Of the 28 children who received the antibiotic, 14 (50%) were cured, 4 (14%) were improved, 4 (14%) experienced treatment failure, and 6 (21%) withdrew. Of the 28 children who received placebo, 4 (14%) were cured, 5 (18%) improved, and 19 (68%) experienced treatment failure. Children receiving the antibiotic were more likely to be cured (50% vs 14%) and less likely to have treatment failure (14% vs 68%) than children receiving the placebo. ABS is a common complication of viral upper respiratory infections. Amoxicillin/potassium clavulanate results in significantly more cures and fewer failures than placebo, according to parental report of time to resolution of clinical symptoms.
Intelligent processing for thick composites
NASA Astrophysics Data System (ADS)
Shin, Daniel Dong-Ok
2000-10-01
Manufacturing thick composite parts are associated with adverse curing conditions such as large in-plane temperature gradient and exotherms. The condition is further aggravated because the manufacturer's cycle and the existing cure control systems do not adequately counter such affects. In response, the forecast-based thermal control system is developed to have better cure control for thick composites. Accurate cure kinetic model is crucial for correctly identifying the amount of heat generated for composite process simulation. A new technique for identifying cure parameters for Hercules AS4/3502 prepreg is presented by normalizing the DSC data. The cure kinetics is based on an autocatalytic model for the proposed method, which uses dynamic and isothermal DSC data to determine its parameters. Existing models are also used to determine kinetic parameters but rendered inadequate because of the material's temperature dependent final degree of cure. The model predictions determined from the new technique showed good agreement to both isothermal and dynamic DSC data. The final degree of cure was also in good agreement with experimental data. A realistic cure simulation model including bleeder ply analysis and compaction is validated with Hercules AS4/3501-6 based laminates. The nonsymmetrical temperature distribution resulting from the presence of bleeder plies agreed well to the model prediction. Some of the discrepancies in the predicted compaction behavior were attributed to inaccurate viscosity and permeability models. The temperature prediction was quite good for the 3cm laminate. The validated process simulation model along with cure kinetics model for AS4/3502 prepreg were integrated into the thermal control system. The 3cm Hercules AS4/3501-6 and AS4/3502 laminate were fabricated. The resulting cure cycles satisfied all imposed requirements by minimizing exotherms and temperature gradient. Although the duration of the cure cycles increased, such phenomena was inevitable since longer time was required to maintain acceptable temperature gradient. The derived cure cycles were slightly different than what was anticipated by the offline simulation. Nevertheless, the system adapted to unanticipated events to satisfy the cure requirements.
Wambier, Letícia; Malaquias, Tamirez; Wambier, Denise Stadler; Patzlaff, Rafael T; Bauer, José; Loguercio, Alessandro D; Reis, Alessandra
2014-06-01
This study evaluated the effects of light exposure times on water sorption, solubility, and polymer cross-linking density of simplified etch-and-rinse adhesives. Four commercial adhesives (XP Bond, Adper Single Bond 2, Tetric N-Bond, and Ambar) were selected, and resin disks 5 mm in diameter and 1.0 mm thick were prepared and light cured for 20, 40, or 80 s using an LED light-curing unit at 1200 mW/cm2. Water sorption and solubility were evaluated over a 28-day period. For polymer cross-linking density, additional specimens were prepared and their Knoop hardness measured before and after immersion in 100% ethanol. The data from each test were evaluated using a two-way ANOVA and Tukey's test (α = 0.05). The XP Bond adhesive showed higher water sorption (similar to Adper Single Bond 2) and solubility (p < 0.05) than did the other materials. Prolonged exposure times did not reduce the water sorption but did reduce the solubility of all tested materials (p < 0.05). For Ambar, the increase in the exposure time resulted in a significantly lower percent reduction in hardness. Water sorption, solubility, and cross-linking density of the materials selected in this study seem to be mainly influenced by the adhesive composition. Prolonged light exposure times reduced the solubility of the materials.
Development of leachate test for delayed ettringite formation potential in cementitious materials
NASA Astrophysics Data System (ADS)
France-Mensah, Jojo
Delayed Ettringite Formation (DEF) has been known to be the cause of expansion and cracking at latter ages in concrete that has been heat cured at temperatures around 70 degree Celsius or above. Currently, the only method available for measuring DEF-related physical expansion in concrete can sometimes take over a year to yield relevant results. A leachate method was proposed as a means of taking advantage of the release and solubility of the adsorbed ions (e.g., calcium, sulfates and aluminates) and alkali ions (e.g., sodium and potassium) in the pore solution after heat curing of the cement paste matrix. These ions, known to contribute to DEF, were leached out of concrete into the leaching solution. The results of the leachate test were correlated to physical expansion data of similar samples from an earlier study. The aim of this research is to apply this knowledge to develop an accelerated leachate test method for identifying the potential for DEF in cementitious materials in a shorter time than the existing method. The objectives of this research are: (1) to identify the ion(s) through leaching that is/are the controlling factors in predicting the rate of expansion and overall expansion of mortar; (2) to identify the ion(s) that is/are responsible for the lag time or age of deleterious expansion through DEF; and (3) to investigate the effect of heat curing on the overall, rate of, and age (time) of expansion.
Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A
2017-01-01
Background Despite drawbacks, cold-cured acrylic resin is still the most common material used in denture repair. Zirconia nanoparticles were among the reinforcements added to increase the strength of the resin. The effect on Candida due to the addition of zirconia nanoparticles to the resin has not been investigated. Purpose The aim of this study was to evaluate the effect of zirconia nanoparticles added to cold-cured acrylic resin on Candida albicans adhesion. Materials and methods A total of 120 acrylic resin specimens with dimensions measuring 22×10×2.5 mm3 were prepared and divided into two equal groups. One group (repair) comprised heat-polymerized specimens that were sectioned at the center and prepared to create a 2 mm repair area that was repaired with cold-cured resin reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. The second group contained intact cold-cured acrylic resin specimens reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. Specimens were incubated at 37°C in artificial saliva containing C. albicans, and the effect of zirconia nanoparticles on C. albicans was assessed using two methods: 1) a slide count method and 2) a direct culture test. Variations in the number of living Candida were observed in relation to the different concentrations of zirconia nanoparticles. Analysis of variance (ANOVA) and post hoc Tukey’s tests were performed for data analysis. If the P-value was ≤0.05, then the difference was considered as statistically significant. Results It was found that C. albicans adhesion to repaired specimens was significantly decreased by the addition of zirconia nanoparticles (P<0.00001) in comparison with the control group. Intact cold-cured groups and groups repaired with cold-cured resin reinforced with 7.5% wt zirconia nanoparticles showed the lowest Candida count. Tukey’s test showed a significant difference between the repaired group and the intact cold-cured group, while the later demonstrated a lower Candida count. Conclusion The addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Clinical significance Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention. PMID:28814859
Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A
2017-01-01
Despite drawbacks, cold-cured acrylic resin is still the most common material used in denture repair. Zirconia nanoparticles were among the reinforcements added to increase the strength of the resin. The effect on Candida due to the addition of zirconia nanoparticles to the resin has not been investigated. The aim of this study was to evaluate the effect of zirconia nanoparticles added to cold-cured acrylic resin on Candida albicans adhesion. A total of 120 acrylic resin specimens with dimensions measuring 22×10×2.5 mm 3 were prepared and divided into two equal groups. One group (repair) comprised heat-polymerized specimens that were sectioned at the center and prepared to create a 2 mm repair area that was repaired with cold-cured resin reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. The second group contained intact cold-cured acrylic resin specimens reinforced with 0% wt, 2.5% wt, 5% wt, and 7.5% wt zirconia nanoparticles. Specimens were incubated at 37°C in artificial saliva containing C. albicans , and the effect of zirconia nanoparticles on C. albicans was assessed using two methods: 1) a slide count method and 2) a direct culture test. Variations in the number of living Candida were observed in relation to the different concentrations of zirconia nanoparticles. Analysis of variance (ANOVA) and post hoc Tukey's tests were performed for data analysis. If the P -value was ≤0.05, then the difference was considered as statistically significant. It was found that C. albicans adhesion to repaired specimens was significantly decreased by the addition of zirconia nanoparticles ( P <0.00001) in comparison with the control group. Intact cold-cured groups and groups repaired with cold-cured resin reinforced with 7.5% wt zirconia nanoparticles showed the lowest Candida count. Tukey's test showed a significant difference between the repaired group and the intact cold-cured group, while the later demonstrated a lower Candida count. The addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention.
Schwebke, Jane R; Marrazzo, Jeanne; Beelen, Andrew P; Sobel, Jack D
2015-07-01
Bacterial vaginosis (BV), a prevalent infection in women of reproductive age, is associated with increased risk of upper genital tract and sexually transmitted infections, and complications in pregnancy. Currently approved treatments include metronidazole, which requires once or twice daily intravaginal administration for 5 days or twice daily oral administration for 7 days. This phase 3 study determined the safety and efficacy of single-dose metronidazole vaginal gel (MVG) 1.3%. In this double-blind, vehicle-controlled study, 651 women with clinical diagnosis of BV were randomized 1:1 to receive MVG 1.3% or vehicle vaginal gel. Primary efficacy measure was clinical cure (normal discharge, negative "whiff test," and <20% clue cells) at day 21. Secondary measures included therapeutic cure (both clinical and bacteriological; day 21) and bacteriologic cure (Nugent score <4), clinical cure, and time to resolution of symptoms (day 7). A total of 487 participants were included in the primary analysis. Clinical and therapeutic cure rates (day 21) were higher in participants treated with MVG 1.3% compared with vehicle gel (37.2% vs. 26.6% [P = 0.010] and 16.8% vs. 7.2% [P = 0.001], respectively). Clinical and bacteriologic cure rates (day 7) were also higher in the MVG 1.3% group (46.0% vs. 20.0% [P < 0.001] and 32.7% vs. 6.3% [P < 0.001], respectively). The median time to resolution of symptoms was shorter in the MVG 1.3% (day 6) than vehicle group (not reached). No serious adverse events were reported, and incidence was similar across treatment groups. Single-dose MVG 1.3% was safe and superior to vehicle gel in producing cure among women with BV.