Sample records for current calibration procedures

  1. Reconstructing the calibrated strain signal in the Advanced LIGO detectors

    NASA Astrophysics Data System (ADS)

    Viets, A. D.; Wade, M.; Urban, A. L.; Kandhasamy, S.; Betzwieser, J.; Brown, Duncan A.; Burguet-Castell, J.; Cahillane, C.; Goetz, E.; Izumi, K.; Karki, S.; Kissel, J. S.; Mendell, G.; Savage, R. L.; Siemens, X.; Tuyenbayev, D.; Weinstein, A. J.

    2018-05-01

    Advanced LIGO’s raw detector output needs to be calibrated to compute dimensionless strain h(t) . Calibrated strain data is produced in the time domain using both a low-latency, online procedure and a high-latency, offline procedure. The low-latency h(t) data stream is produced in two stages, the first of which is performed on the same computers that operate the detector’s feedback control system. This stage, referred to as the front-end calibration, uses infinite impulse response (IIR) filtering and performs all operations at a 16 384 Hz digital sampling rate. Due to several limitations, this procedure currently introduces certain systematic errors in the calibrated strain data, motivating the second stage of the low-latency procedure, known as the low-latency gstlal calibration pipeline. The gstlal calibration pipeline uses finite impulse response (FIR) filtering to apply corrections to the output of the front-end calibration. It applies time-dependent correction factors to the sensing and actuation components of the calibrated strain to reduce systematic errors. The gstlal calibration pipeline is also used in high latency to recalibrate the data, which is necessary due mainly to online dropouts in the calibrated data and identified improvements to the calibration models or filters.

  2. Video-guided calibration of an augmented reality mobile C-arm.

    PubMed

    Chen, Xin; Naik, Hemal; Wang, Lejing; Navab, Nassir; Fallavollita, Pascal

    2014-11-01

    The augmented reality (AR) fluoroscope augments an X-ray image by video and provides the surgeon with a real-time in situ overlay of the anatomy. The overlay alignment is crucial for diagnostic and intra-operative guidance, so precise calibration of the AR fluoroscope is required. The first and most complex step of the calibration procedure is the determination of the X-ray source position. Currently, this is achieved using a biplane phantom with movable metallic rings on its top layer and fixed X-ray opaque markers on its bottom layer. The metallic rings must be moved to positions where at least two pairs of rings and markers are isocentric in the X-ray image. The current "trial and error" calibration process currently requires acquisition of many X-ray images, a task that is both time consuming and radiation intensive. An improved process was developed and tested for C-arm calibration. Video guidance was used to drive the calibration procedure to minimize both X-ray exposure and the time involved. For this, a homography between X-ray and video images is estimated. This homography is valid for the plane at which the metallic rings are positioned and is employed to guide the calibration procedure. Eight users having varying calibration experience (i.e., 2 experts, 2 semi-experts, 4 novices) were asked to participate in the evaluation. The video-guided technique reduced the number of intra-operative X-ray calibration images by 89% and decreased the total time required by 59%. A video-based C-arm calibration method has been developed that improves the usability of the AR fluoroscope with a friendlier interface, reduced calibration time and clinically acceptable radiation doses.

  3. HYDICE postflight data processing

    NASA Astrophysics Data System (ADS)

    Aldrich, William S.; Kappus, Mary E.; Resmini, Ronald G.; Mitchell, Peter A.

    1996-06-01

    The hyperspectral digital imagery collection experiment (HYDICE) sensor records instrument counts for scene data, in-flight spectral and radiometric calibration sequences, and dark current levels onto an AMPEX DCRsi data tape. Following flight, the HYDICE ground data processing subsystem (GDPS) transforms selected scene data from digital numbers (DN) to calibrated radiance levels at the sensor aperture. This processing includes: dark current correction, spectral and radiometric calibration, conversion to radiance, and replacement of bad detector elements. A description of the algorithms for post-flight data processing is presented. A brief analysis of the original radiometric calibration procedure is given, along with a description of the development of the modified procedure currently used. Example data collected during the 1995 flight season, but uncorrected and processed, are shown to demonstrate the removal of apparent sensor artifacts (e.g., non-uniformities in detector response over the array) as a result of this transformation.

  4. Calibration procedures for imaging spectrometers: improving data quality from satellite missions to UAV campaigns

    NASA Astrophysics Data System (ADS)

    Brachmann, Johannes F. S.; Baumgartner, Andreas; Lenhard, Karim

    2016-10-01

    The Calibration Home Base (CHB) at the Remote Sensing Technology Institute of the German Aerospace Center (DLR-IMF) is an optical laboratory designed for the calibration of imaging spectrometers for the VNIR/SWIR wavelength range. Radiometric, spectral and geometric characterization is realized in the CHB in a precise and highly automated fashion. This allows performing a wide range of time consuming measurements in an efficient way. The implementation of ISO 9001 standards ensures a traceable quality of results. DLR-IMF will support the calibration and characterization campaign of the future German spaceborne hyperspectral imager EnMAP. In the context of this activity, a procedure for the correction of imaging artifacts, such as due to stray light, is currently being developed by DLR-IMF. Goal is the correction of in-band stray light as well as ghost images down to a level of a few digital numbers in the whole wavelength range 420-2450 nm. DLR-IMF owns a Norsk Elektro Optikks HySpex airborne imaging spectrometer system that has been thoroughly characterized. This system will be used to test stray light calibration procedures for EnMAP. Hyperspectral snapshot sensors offer the possibility to simultaneously acquire hyperspectral data in two dimensions. Recently, these rather new spectrometers have arisen much interest in the remote sensing community. Different designs are currently used for local area observation such as by use of small unmanned aerial vehicles (sUAV). In this context the CHB's measurement capabilities are currently extended such that a standard measurement procedure for these new sensors will be implemented.

  5. Calibration and Temperature Profile of a Tungsten Filament Lamp

    ERIC Educational Resources Information Center

    de Izarra, Charles; Gitton, Jean-Michel

    2010-01-01

    The goal of this work proposed for undergraduate students and teachers is the calibration of a tungsten filament lamp from electric measurements that are both simple and precise, allowing to determine the temperature of tungsten filament as a function of the current intensity. This calibration procedure was first applied to a conventional filament…

  6. Hydrological processes and model representation: impact of soft data on calibration

    Treesearch

    J.G. Arnold; M.A. Youssef; H. Yen; M.J. White; A.Y. Sheshukov; A.M. Sadeghi; D.N. Moriasi; J.L. Steiner; Devendra Amatya; R.W. Skaggs; E.B. Haney; J. Jeong; M. Arabi; P.H. Gowda

    2015-01-01

    Hydrologic and water quality models are increasingly used to determine the environmental impacts of climate variability and land management. Due to differing model objectives and differences in monitored data, there are currently no universally accepted procedures for model calibration and validation in the literature. In an effort to develop accepted model calibration...

  7. A new calibration code for the JET polarimeter.

    PubMed

    Gelfusa, M; Murari, A; Gaudio, P; Boboc, A; Brombin, M; Orsitto, F P; Giovannozzi, E

    2010-05-01

    An equivalent model of JET polarimeter is presented, which overcomes the drawbacks of previous versions of the fitting procedures used to provide calibrated results. First of all the signal processing electronics has been simulated, to confirm that it is still working within the original specifications. Then the effective optical path of both the vertical and lateral chords has been implemented to produce the calibration curves. The principle approach to the model has allowed obtaining a unique procedure which can be applied to any manual calibration and remains constant until the following one. The optical model of the chords is then applied to derive the plasma measurements. The results are in good agreement with the estimates of the most advanced full wave propagation code available and have been benchmarked with other diagnostics. The devised procedure has proved to work properly also for the most recent campaigns and high current experiments.

  8. Toward Increasing Fairness in Score Scale Calibrations Employed in International Large-Scale Assessments

    ERIC Educational Resources Information Center

    Oliveri, Maria Elena; von Davier, Matthias

    2014-01-01

    In this article, we investigate the creation of comparable score scales across countries in international assessments. We examine potential improvements to current score scale calibration procedures used in international large-scale assessments. Our approach seeks to improve fairness in scoring international large-scale assessments, which often…

  9. The analytical calibration in (bio)imaging/mapping of the metallic elements in biological samples--definitions, nomenclature and strategies: state of the art.

    PubMed

    Jurowski, Kamil; Buszewski, Bogusław; Piekoszewski, Wojciech

    2015-01-01

    Nowadays, studies related to the distribution of metallic elements in biological samples are one of the most important issues. There are many articles dedicated to specific analytical atomic spectrometry techniques used for mapping/(bio)imaging the metallic elements in various kinds of biological samples. However, in such literature, there is a lack of articles dedicated to reviewing calibration strategies, and their problems, nomenclature, definitions, ways and methods used to obtain quantitative distribution maps. The aim of this article was to characterize the analytical calibration in the (bio)imaging/mapping of the metallic elements in biological samples including (1) nomenclature; (2) definitions, and (3) selected and sophisticated, examples of calibration strategies with analytical calibration procedures applied in the different analytical methods currently used to study an element's distribution in biological samples/materials such as LA ICP-MS, SIMS, EDS, XRF and others. The main emphasis was placed on the procedures and methodology of the analytical calibration strategy. Additionally, the aim of this work is to systematize the nomenclature for the calibration terms: analytical calibration, analytical calibration method, analytical calibration procedure and analytical calibration strategy. The authors also want to popularize the division of calibration methods that are different than those hitherto used. This article is the first work in literature that refers to and emphasizes many different and complex aspects of analytical calibration problems in studies related to (bio)imaging/mapping metallic elements in different kinds of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. An IMU-to-Body Alignment Method Applied to Human Gait Analysis.

    PubMed

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-12-10

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

  11. Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    PubMed

    van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W

    2016-07-01

    Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.

  12. Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population

    PubMed Central

    Gandolla, Marta; Guanziroli, Eleonora; D'Angelo, Andrea; Cannaviello, Giovanni; Molteni, Franco; Pedrocchi, Alessandra

    2018-01-01

    Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial—it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be robust, and to be in agreement with the current gold standard (i.e., manual calibration performed by an expert engineer). The use of a graphical user interface is a promising tool for the effective use of an automatic procedure in a clinical context. PMID:29615890

  13. Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population.

    PubMed

    Gandolla, Marta; Guanziroli, Eleonora; D'Angelo, Andrea; Cannaviello, Giovanni; Molteni, Franco; Pedrocchi, Alessandra

    2018-01-01

    Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial-it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be robust, and to be in agreement with the current gold standard (i.e., manual calibration performed by an expert engineer). The use of a graphical user interface is a promising tool for the effective use of an automatic procedure in a clinical context.

  14. Observed Score and True Score Equating Procedures for Multidimensional Item Response Theory

    ERIC Educational Resources Information Center

    Brossman, Bradley Grant

    2010-01-01

    The purpose of this research was to develop observed score and true score equating procedures to be used in conjunction with the Multidimensional Item Response Theory (MIRT) framework. Currently, MIRT scale linking procedures exist to place item parameter estimates and ability estimates on the same scale after separate calibrations are conducted.…

  15. Consistency of L4 TM absolute calibration with respect to the L5 TM sensor based on near-simultaneous image acquisition

    NASA Astrophysics Data System (ADS)

    Chander, Gyanesh; Helder, Dennis L.; Malla, Rimy; Micijevic, Esad; Mettler, Cory J.

    2007-09-01

    The Landsat archive provides more than 35 years of uninterrupted multispectral remotely sensed data of Earth observations. Since 1972, Landsat missions have carried different types of sensors, from the Return Beam Vidicon (RBV) camera to the Enhanced Thematic Mapper Plus (ETM+). However, the Thematic Mapper (TM) sensors on Landsat 4 (L4) and Landsat 5 (L5), launched in 1982 and 1984 respectively, are the backbone of an extensive archive. Effective April 2, 2007, the radiometric calibration of L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) was updated to use an improved lifetime gain model, based on the instrument's detector response to pseudo-invariant desert site data and cross-calibration with the L7 ETM+. However, no modifications were ever made to the radiometric calibration procedure of the Landsat 4 (L4) TM data. The L4 TM radiometric calibration procedure has continued to use the Internal Calibrator (IC) based calibration algorithms and the post calibration dynamic ranges, as previously defined. To evaluate the "current" absolute accuracy of these two sensors, image pairs from the L5 TM and L4 TM sensors were compared. The number of coincident image pairs in the USGS EROS archive is limited, so the scene selection for the cross-calibration studies proved to be a challenge. Additionally, because of the lack of near-simultaneous images available over well-characterized and traditionally used calibration sites, alternate sites that have high reflectance, large dynamic range, high spatial uniformity, high sun elevation, and minimal cloud cover were investigated. The alternate sites were identified in Yuma, Iraq, Egypt, Libya, and Algeria. The cross-calibration approach involved comparing image statistics derived from large common areas observed eight days apart by the two sensors. This paper summarizes the average percent differences in reflectance estimates obtained between the two sensors. The work presented in this paper is a first step in understanding the current performance of L4 TM absolute calibration and potentially serves as a platform to revise and improve the radiometric calibration procedures implemented for the processing of L4 TM data.

  16. Consistency of L4 TM absolute calibration with respect to the L5 TM sensor based on near-simultaneous image acquisition

    USGS Publications Warehouse

    Chander, G.; Helder, D.L.; Malla, R.; Micijevic, E.; Mettler, C.J.

    2007-01-01

    The Landsat archive provides more than 35 years of uninterrupted multispectral remotely sensed data of Earth observations. Since 1972, Landsat missions have carried different types of sensors, from the Return Beam Vidicon (RBV) camera to the Enhanced Thematic Mapper Plus (ETM+). However, the Thematic Mapper (TM) sensors on Landsat 4 (L4) and Landsat 5 (L5), launched in 1982 and 1984 respectively, are the backbone of an extensive archive. Effective April 2, 2007, the radiometric calibration of L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) was updated to use an improved lifetime gain model, based on the instrument's detector response to pseudo-invariant desert site data and cross-calibration with the L7 ETM+. However, no modifications were ever made to the radiometric calibration procedure of the Landsat 4 (L4) TM data. The L4 TM radiometric calibration procedure has continued to use the Internal Calibrator (IC) based calibration algorithms and the post calibration dynamic ranges, as previously defined. To evaluate the "current" absolute accuracy of these two sensors, image pairs from the L5 TM and L4 TM sensors were compared. The number of coincident image pairs in the USGS EROS archive is limited, so the scene selection for the cross-calibration studies proved to be a challenge. Additionally, because of the lack of near-simultaneous images available over well-characterized and traditionally used calibration sites, alternate sites that have high reflectance, large dynamic range, high spatial uniformity, high sun elevation, and minimal cloud cover were investigated. The alternate sites were identified in Yuma, Iraq, Egypt, Libya, and Algeria. The cross-calibration approach involved comparing image statistics derived from large common areas observed eight days apart by the two sensors. This paper summarizes the average percent differences in reflectance estimates obtained between the two sensors. The work presented in this paper is a first step in understanding the current performance of L4 TM absolute calibration and potentially serves as a platform to revise and improve the radiometric calibration procedures implemented for the processing of L4 TM data.

  17. Force Measurement Services at Kebs: AN Overview of Equipment, Procedures and Uncertainty

    NASA Astrophysics Data System (ADS)

    Bangi, J. O.; Maranga, S. M.; Nganga, S. P.; Mutuli, S. M.

    This paper describes the facilities, instrumentation and procedures currently used in the force laboratory at the Kenya Bureau of Standards (KEBS) for force measurement services. The laboratory uses the Force Calibration Machine (FCM) to calibrate force-measuring instruments. The FCM derives its traceability via comparisons using reference transfer force transducers calibrated by the Force Standard Machines (FSM) of a National Metrology Institute (NMI). The force laboratory is accredited to ISO/IEC 17025 by the Germany Accreditation Body (DAkkS). The accredited measurement scope of the laboratory is 1 MN to calibrate force transducers in both compression and tension modes. ISO 376 procedures are used while calibrating force transducers. The KEBS reference transfer standards have capacities of 10, 50, 300 and 1000 kN to cover the full range of the FCM. The uncertainty in the forces measured by the FCM were reviewed and determined in accordance to the new EURAMET calibration guide. The relative expanded uncertainty of force W realized by FCM was evaluated in a range from 10 kN-1 MN, and was found to be 5.0 × 10-4 with the coverage factor k being equal to 2. The overall normalized error (En) of the comparison results was also found to be less than 1. The accredited Calibration and Measurement Capability (CMC) of the KEBS force laboratory was based on the results of those intercomparisons. The FCM enables KEBS to provide traceability for the calibration of class ‘1’ force instruments as per the ISO 376.

  18. SCALA: In situ calibration for integral field spectrographs

    NASA Astrophysics Data System (ADS)

    Lombardo, S.; Küsters, D.; Kowalski, M.; Aldering, G.; Antilogus, P.; Bailey, S.; Baltay, C.; Barbary, K.; Baugh, D.; Bongard, S.; Boone, K.; Buton, C.; Chen, J.; Chotard, N.; Copin, Y.; Dixon, S.; Fagrelius, P.; Feindt, U.; Fouchez, D.; Gangler, E.; Hayden, B.; Hillebrandt, W.; Hoffmann, A.; Kim, A. G.; Leget, P.-F.; McKay, L.; Nordin, J.; Pain, R.; Pécontal, E.; Pereira, R.; Perlmutter, S.; Rabinowitz, D.; Reif, K.; Rigault, M.; Rubin, D.; Runge, K.; Saunders, C.; Smadja, G.; Suzuki, N.; Taubenberger, S.; Tao, C.; Thomas, R. C.; Nearby Supernova Factory

    2017-11-01

    Aims: The scientific yield of current and future optical surveys is increasingly limited by systematic uncertainties in the flux calibration. This is the case for type Ia supernova (SN Ia) cosmology programs, where an improved calibration directly translates into improved cosmological constraints. Current methodology rests on models of stars. Here we aim to obtain flux calibration that is traceable to state-of-the-art detector-based calibration. Methods: We present the SNIFS Calibration Apparatus (SCALA), a color (relative) flux calibration system developed for the SuperNova integral field spectrograph (SNIFS), operating at the University of Hawaii 2.2 m (UH 88) telescope. Results: By comparing the color trend of the illumination generated by SCALA during two commissioning runs, and to previous laboratory measurements, we show that we can determine the light emitted by SCALA with a long-term repeatability better than 1%. We describe the calibration procedure necessary to control for system aging. We present measurements of the SNIFS throughput as estimated by SCALA observations. Conclusions: The SCALA calibration unit is now fully deployed at the UH 88 telescope, and with it color-calibration between 4000 Å and 9000 Å is stable at the percent level over a one-year baseline.

  19. Calibration of areal surface topography measuring instruments

    NASA Astrophysics Data System (ADS)

    Seewig, J.; Eifler, M.

    2017-06-01

    The ISO standards which are related to the calibration of areal surface topography measuring instruments are the ISO 25178-6xx series which defines the relevant metrological characteristics for the calibration of different measuring principles and the ISO 25178-7xx series which defines the actual calibration procedures. As the field of areal measurement is however not yet fully standardized, there are still open questions to be addressed which are subject to current research. Based on this, selected research results of the authors in this area are presented. This includes the design and fabrication of areal material measures. For this topic, two examples are presented with the direct laser writing of a stepless material measure for the calibration of the height axis which is based on the Abbott- Curve and the manufacturing of a Siemens star for the determination of the lateral resolution limit. Based on these results, as well a new definition for the resolution criterion, the small scale fidelity, which is still under discussion, is presented. Additionally, a software solution for automated calibration procedures is outlined.

  20. In Search of Easy-to-Use Methods for Calibrating ADCP's for Velocity and Discharge Measurements

    USGS Publications Warehouse

    Oberg, K.; ,

    2002-01-01

    A cost-effective procedure for calibrating acoustic Doppler current profilers (ADCP) in the field was presented. The advantages and disadvantages of various methods which are used for calibrating ADCP were discussed. The proposed method requires the use of differential global positioning system (DGPS) with sub-meter accuracy and standard software for collecting ADCP data. The method involves traversing a long (400-800 meter) course at a constant compass heading and speed, while collecting simultaneous DGPS and ADCP data.

  1. 8s, a numerical simulator of the challenging optical calibration of the E-ELT adaptive mirror M4

    NASA Astrophysics Data System (ADS)

    Briguglio, Runa; Pariani, Giorgio; Xompero, Marco; Riccardi, Armando; Tintori, Matteo; Lazzarini, Paolo; Spanò, Paolo

    2016-07-01

    8s stands for Optical Test TOwer Simulator (with 8 read as in italian 'otto'): it is a simulation tool for the optical calibration of the E-ELT deformable mirror M4 on its test facility. It has been developed to identify possible criticalities in the procedure, evaluate the solutions and estimate the sensitivity to environmental noise. The simulation system is composed by the finite elements model of the tower, the analytic influence functions of the actuators, the ray tracing propagation of the laser beam through the optical surfaces. The tool delivers simulated phasemaps of M4, associated with the current system status: actuator commands, optics alignment and position, beam vignetting, bench temperature and vibrations. It is possible to simulate a single step of the optical test of M4 by changing the system parameters according to a calibration procedure and collect the associated phasemap for performance evaluation. In this paper we will describe the simulation package and outline the proposed calibration procedure of M4.

  2. An IMU-to-Body Alignment Method Applied to Human Gait Analysis

    PubMed Central

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-01-01

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis. PMID:27973406

  3. Calibration of transonic and supersonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Reed, T. D.; Pope, T. C.; Cooksey, J. M.

    1977-01-01

    State-of-the art instrumentation and procedures for calibrating transonic (0.6 less than M less than 1.4) and supersonic (M less than or equal to 3.5) wind tunnels were reviewed and evaluated. Major emphasis was given to transonic tunnels. Continuous, blowdown and intermittent tunnels were considered. The required measurements of pressure, temperature, flow angularity, noise and humidity were discussed, and the effects of measurement uncertainties were summarized. A comprehensive review of instrumentation currently used to calibrate empty tunnel flow conditions was included. The recent results of relevant research are noted and recommendations for achieving improved data accuracy are made where appropriate. It is concluded, for general testing purposes, that satisfactory calibration measurements can be achieved in both transonic and supersonic tunnels. The goal of calibrating transonic tunnels to within 0.001 in centerline Mach number appears to be feasible with existing instrumentation, provided correct calibration procedures are carefully followed. A comparable accuracy can be achieved off-centerline with carefully designed, conventional probes, except near Mach 1. In the range 0.95 less than M less than 1.05, the laser Doppler velocimeter appears to offer the most promise for improved calibration accuracy off-centerline.

  4. Solid State Power Controller Fuse Development Program.

    DTIC Science & Technology

    1983-10-01

    4NYP Appendix A nic =,-, ’XW LX, nII4CD1AFam" CC,’AP44 257-290 TABLE I - FAULT CURRENT TRIP TJMWS Fa’ Ii AC Volts Seconds Rema:ks 1. 1.6 100Z 234.0 417.0...calibration date: 12 July 1983 Biddle Power Rheostat, 1000 W, Cat. No. 20 4.2 Procedure Testing was accomplished in two lots, one consisting of the SPC-2A and...Last calibration date: 12 July 1983 Biddle 100dW Power Rheostat, Cat. No. 20 Variac, Environ No. 380-503 4.2 Procedure The test specimens were suspended

  5. ASCAL: A Microcomputer Program for Estimating Logistic IRT Item Parameters.

    ERIC Educational Resources Information Center

    Vale, C. David; Gialluca, Kathleen A.

    ASCAL is a microcomputer-based program for calibrating items according to the three-parameter logistic model of item response theory. It uses a modified multivariate Newton-Raphson procedure for estimating item parameters. This study evaluated this procedure using Monte Carlo Simulation Techniques. The current version of ASCAL was then compared to…

  6. Standard Procedure for Calibrating an Areal Calorimetry Based Dosimeter

    DTIC Science & Technology

    2015-05-01

    detector target surface. In this case, the source was on for approximately 2.5 s, shortly after which the data acquisition ends. For this shot , the...no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control...48 APPENDIX D – CALIBRATION DATA SHOT RESULTS ...................................................... 49 APPENDIX E – SAMPLE

  7. Extrinsic Calibration of a Laser Galvanometric Setup and a Range Camera.

    PubMed

    Sels, Seppe; Bogaerts, Boris; Vanlanduit, Steve; Penne, Rudi

    2018-05-08

    Currently, galvanometric scanning systems (like the one used in a scanning laser Doppler vibrometer) rely on a planar calibration procedure between a two-dimensional (2D) camera and the laser galvanometric scanning system to automatically aim a laser beam at a particular point on an object. In the case of nonplanar or moving objects, this calibration is not sufficiently accurate anymore. In this work, a three-dimensional (3D) calibration procedure that uses a 3D range sensor is proposed. The 3D calibration is valid for all types of objects and retains its accuracy when objects are moved between subsequent measurement campaigns. The proposed 3D calibration uses a Non-Perspective-n-Point (NPnP) problem solution. The 3D range sensor is used to calculate the position of the object under test relative to the laser galvanometric system. With this extrinsic calibration, the laser galvanometric scanning system can automatically aim a laser beam to this object. In experiments, the mean accuracy of aiming the laser beam on an object is below 10 mm for 95% of the measurements. This achieved accuracy is mainly determined by the accuracy and resolution of the 3D range sensor. The new calibration method is significantly better than the original 2D calibration method, which in our setup achieves errors below 68 mm for 95% of the measurements.

  8. Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vilches-Freixas, Gloria; Létang, Jean Michel; Rit,

    2016-09-15

    Purpose: The aim of this work is to propose a general and simple procedure for the calibration and validation of kilo-voltage cone-beam CT (kV CBCT) models against experimental data. Methods: The calibration and validation of the CT model is a two-step procedure: the source model then the detector model. The source is described by the direction dependent photon energy spectrum at each voltage while the detector is described by the pixel intensity value as a function of the direction and the energy of incident photons. The measurements for the source consist of a series of dose measurements in air performedmore » at each voltage with varying filter thicknesses and materials in front of the x-ray tube. The measurements for the detector are acquisitions of projection images using the same filters and several tube voltages. The proposed procedure has been applied to calibrate and assess the accuracy of simple models of the source and the detector of three commercial kV CBCT units. If the CBCT system models had been calibrated differently, the current procedure would have been exclusively used to validate the models. Several high-purity attenuation filters of aluminum, copper, and silver combined with a dosimeter which is sensitive to the range of voltages of interest were used. A sensitivity analysis of the model has also been conducted for each parameter of the source and the detector models. Results: Average deviations between experimental and theoretical dose values are below 1.5% after calibration for the three x-ray sources. The predicted energy deposited in the detector agrees with experimental data within 4% for all imaging systems. Conclusions: The authors developed and applied an experimental procedure to calibrate and validate any model of the source and the detector of a CBCT unit. The present protocol has been successfully applied to three x-ray imaging systems. The minimum requirements in terms of material and equipment would make its implementation suitable in most clinical environments.« less

  9. A Focusing Method in the Calibration Process of Image Sensors Based on IOFBs

    PubMed Central

    Fernández, Pedro R.; Lázaro, José L.; Gardel, Alfredo; Cano, Ángel E.; Bravo, Ignacio

    2010-01-01

    A focusing procedure in the calibration process of image sensors based on Incoherent Optical Fiber Bundles (IOFBs) is described using the information extracted from fibers. These procedures differ from any other currently known focusing method due to the non spatial in-out correspondence between fibers, which produces a natural codification of the image to transmit. Focus measuring is essential prior to carrying out calibration in order to guarantee accurate processing and decoding. Four algorithms have been developed to estimate the focus measure; two methods based on mean grey level, and the other two based on variance. In this paper, a few simple focus measures are defined and compared. Some experimental results referred to the focus measure and the accuracy of the developed methods are discussed in order to demonstrate its effectiveness. PMID:22315526

  10. Prediction of SOFC Performance with or without Experiments: A Study on Minimum Requirements for Experimental Data

    DOE PAGES

    Yang, Tao; Sezer, Hayri; Celik, Ismail B.; ...

    2015-06-02

    In the present paper, a physics-based procedure combining experiments and multi-physics numerical simulations is developed for overall analysis of SOFCs operational diagnostics and performance predictions. In this procedure, essential information for the fuel cell is extracted first by utilizing empirical polarization analysis in conjunction with experiments and refined by multi-physics numerical simulations via simultaneous analysis and calibration of polarization curve and impedance behavior. The performance at different utilization cases and operating currents is also predicted to confirm the accuracy of the proposed model. It is demonstrated that, with the present electrochemical model, three air/fuel flow conditions are needed to producemore » a set of complete data for better understanding of the processes occurring within SOFCs. After calibration against button cell experiments, the methodology can be used to assess performance of planar cell without further calibration. The proposed methodology would accelerate the calibration process and improve the efficiency of design and diagnostics.« less

  11. Maximum likelihood estimation in calibrating a stereo camera setup.

    PubMed

    Muijtjens, A M; Roos, J M; Arts, T; Hasman, A

    1999-02-01

    Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-20 radiopaque markers at known positions. Unfortunately, an accidental change of the position of a camera after calibration requires complete recalibration. Alternatively, redundant information in the measured image positions of stereo pairs can be used for calibration. Thus, a separate calibration procedure can be avoided. In the current study a model is developed that describes the geometry of the camera setup by five dimensionless parameters. Maximum Likelihood (ML) estimates of these parameters were obtained in an error analysis. It is shown that the ML estimates can be found by application of a nonlinear least squares procedure. Compared to the standard unweighted least squares procedure, the ML method resulted in more accurate estimates without noticeable bias. The accuracy of the ML method was investigated in relation to the object aperture. The reconstruction problem appeared well conditioned as long as the object aperture is larger than 0.1 rad. The angle between the two viewing directions appeared to be the parameter that was most likely to cause major inaccuracies in the reconstruction of the 3-D positions of the markers. Hence, attempts to improve the robustness of the method should primarily focus on reduction of the error in this parameter.

  12. A procedure for accurate calibration of the orientation of the three sensors in a vector magnetometer. [at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Mcpherron, R. L.

    1977-01-01

    Procedures are described for the calibration of a vector magnetometer of high absolute accuracy. It is assumed that the calibration will be performed in the magnetic test facility of Goddard Space Flight Center (GSFC). The first main section of the report describes the test equipment and facility calibrations required. The second presents procedures for calibrating individual sensors. The third discusses the calibration of the sensor assembly. In a final section recommendations are made to GSFC for modification of the test facility required to carry out the calibration procedures.

  13. Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO

    NASA Astrophysics Data System (ADS)

    Kim, Myong-Seop; Park, Byung-Gun; Kang, Gi-Doo

    2018-01-01

    A calibration technology of the self-powered neutron detectors (SPNDs) using a large vertical irradiation hole of HANARO is developed. The 40 Rh-SPNDs are installed on the polycarbonate plastic support, and the gold wires with the same length as the effective length of the rhodium emitter of the SPND are also installed to measure the neutron flux on the SPND. They are irradiated at a low reactor power, and the SPND current is measured using the pico-ammeter. The external gamma-rays which affect the SPND current response are analyzed using the Monte Carlo simulation for various irradiation conditions in HANARO. It is confirmed that the effect of the external gamma-rays to the SPND current is dependent on the reactor characteristics, and that it is affected by materials around the detector. The current signals due to the external gamma-rays can be either positive or negative, in that the net flow of the current may be either in the same or the opposite direction as the neutron-induced current by the rhodium emitter. From the above procedure, the effective calibration methodology of multiple SPNDs using the large hole of HANARO is developed. It could be useful for the calibration experiment of the neutron detectors in the research reactors.

  14. Implementation and local calibration of the MEPDG transfer functions in Wyoming.

    DOT National Transportation Integrated Search

    2015-11-01

    The Wyoming Department of Transportation (WYDOT) currently uses the empirical AASHTO Design for Design of : Pavement Structures as their standard pavement design procedure. WYDOT plans to transition to the Mechanistic : Empirical Pavement Design Guid...

  15. Calibration of the MEPDG transfer functions in Georgia : task order 2 report.

    DOT National Transportation Integrated Search

    2015-03-28

    The Georgia Department of Transportation (GDOT) currently uses the empirical 1972 AASHTO Interim Guide for : Design of Pavement Structures as their standard pavement design procedure. However, GDOT plans to transition to the : Mechanistic Empirical P...

  16. Time Transfer Through Optical Fibers (TTTOF): First Results of Calibrated Clock Comparisons

    DTIC Science & Technology

    2009-11-01

    satellite time and frequency transfer ( TWSTFT ) scheme. We discuss procedures for a proper calibration of such time transfer through optical fibers links... TWSTFT ground stations, which are currently spread over the PTB campus, to a common location at a Report Documentation Page Form ApprovedOMB No. 0704...PTTI) Meeting 90 new site (see Figure 1 and [6] for details). From late 2010 onwards, the TWSTFT stations will be installed on top of a high

  17. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...

  18. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and linearity checks (e.g., how gases are to be injected..., and when calibration adjustments should be made). Identify any calibration error test and linearity...

  19. Multiple-Objective Stepwise Calibration Using Luca

    USGS Publications Warehouse

    Hay, Lauren E.; Umemoto, Makiko

    2007-01-01

    This report documents Luca (Let us calibrate), a multiple-objective, stepwise, automated procedure for hydrologic model calibration and the associated graphical user interface (GUI). Luca is a wizard-style user-friendly GUI that provides an easy systematic way of building and executing a calibration procedure. The calibration procedure uses the Shuffled Complex Evolution global search algorithm to calibrate any model compiled with the U.S. Geological Survey's Modular Modeling System. This process assures that intermediate and final states of the model are simulated consistently with measured values.

  20. Methods for accurate estimation of net discharge in a tidal channel

    USGS Publications Warehouse

    Simpson, M.R.; Bland, R.

    2000-01-01

    Accurate estimates of net residual discharge in tidally affected rivers and estuaries are possible because of recently developed ultrasonic discharge measurement techniques. Previous discharge estimates using conventional mechanical current meters and methods based on stage/discharge relations or water slope measurements often yielded errors that were as great as or greater than the computed residual discharge. Ultrasonic measurement methods consist of: 1) the use of ultrasonic instruments for the measurement of a representative 'index' velocity used for in situ estimation of mean water velocity and 2) the use of the acoustic Doppler current discharge measurement system to calibrate the index velocity measurement data. Methods used to calibrate (rate) the index velocity to the channel velocity measured using the Acoustic Doppler Current Profiler are the most critical factors affecting the accuracy of net discharge estimation. The index velocity first must be related to mean channel velocity and then used to calculate instantaneous channel discharge. Finally, discharge is low-pass filtered to remove the effects of the tides. An ultrasonic velocity meter discharge-measurement site in a tidally affected region of the Sacramento-San Joaquin Rivers was used to study the accuracy of the index velocity calibration procedure. Calibration data consisting of ultrasonic velocity meter index velocity and concurrent acoustic Doppler discharge measurement data were collected during three time periods. Two sets of data were collected during a spring tide (monthly maximum tidal current) and one of data collected during a neap tide (monthly minimum tidal current). The relative magnitude of instrumental errors, acoustic Doppler discharge measurement errors, and calibration errors were evaluated. Calibration error was found to be the most significant source of error in estimating net discharge. Using a comprehensive calibration method, net discharge estimates developed from the three sets of calibration data differed by less than an average of 4 cubic meters per second, or less than 0.5% of a typical peak tidal discharge rate of 750 cubic meters per second.

  1. Historical Precision of an Ozone Correction Procedure for AM0 Solar Cell Calibration

    NASA Technical Reports Server (NTRS)

    Snyder, David B.; Jenkins, Phillip; Scheiman, David

    2005-01-01

    In an effort to improve the accuracy of the high altitude aircraft method for calibration of high band-gap solar cells, the ozone correction procedure has been revisited. The new procedure adjusts the measured short circuit current, Isc, according to satellite based ozone measurements and a model of the atmospheric ozone profile then extrapolates the measurements to air mass zero, AMO. The purpose of this paper is to assess the precision of the revised procedure by applying it to historical data sets. The average Isc of a silicon cell for a flying season increased 0.5% and the standard deviation improved from 0.5% to 0.3%. The 12 year average Isc of a GaAs cell increased 1% and the standard deviation improved from 0.8% to 0.5%. The slight increase in measured Isc and improvement in standard deviation suggests that the accuracy of the aircraft method may improve from 1% to nearly 0.5%.

  2. Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.

    2001-01-01

    This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

  3. Improving the Thermal, Radial and Temporal Accuracy of the Analytical Ultracentrifuge through External References

    PubMed Central

    Ghirlando, Rodolfo; Balbo, Andrea; Piszczek, Grzegorz; Brown, Patrick H.; Lewis, Marc S.; Brautigam, Chad A.; Schuck, Peter; Zhao, Huaying

    2013-01-01

    Sedimentation velocity (SV) is a method based on first-principles that provides a precise hydrodynamic characterization of macromolecules in solution. Due to recent improvements in data analysis, the accuracy of experimental SV data emerges as a limiting factor in its interpretation. Our goal was to unravel the sources of experimental error and develop improved calibration procedures. We implemented the use of a Thermochron iButton® temperature logger to directly measure the temperature of a spinning rotor, and detected deviations that can translate into an error of as much as 10% in the sedimentation coefficient. We further designed a precision mask with equidistant markers to correct for instrumental errors in the radial calibration, which were observed to span a range of 8.6%. The need for an independent time calibration emerged with use of the current data acquisition software (Zhao et al., doi 10.1016/j.ab.2013.02.011) and we now show that smaller but significant time errors of up to 2% also occur with earlier versions. After application of these calibration corrections, the sedimentation coefficients obtained from eleven instruments displayed a significantly reduced standard deviation of ∼ 0.7 %. This study demonstrates the need for external calibration procedures and regular control experiments with a sedimentation coefficient standard. PMID:23711724

  4. Improving the thermal, radial, and temporal accuracy of the analytical ultracentrifuge through external references.

    PubMed

    Ghirlando, Rodolfo; Balbo, Andrea; Piszczek, Grzegorz; Brown, Patrick H; Lewis, Marc S; Brautigam, Chad A; Schuck, Peter; Zhao, Huaying

    2013-09-01

    Sedimentation velocity (SV) is a method based on first principles that provides a precise hydrodynamic characterization of macromolecules in solution. Due to recent improvements in data analysis, the accuracy of experimental SV data emerges as a limiting factor in its interpretation. Our goal was to unravel the sources of experimental error and develop improved calibration procedures. We implemented the use of a Thermochron iButton temperature logger to directly measure the temperature of a spinning rotor and detected deviations that can translate into an error of as much as 10% in the sedimentation coefficient. We further designed a precision mask with equidistant markers to correct for instrumental errors in the radial calibration that were observed to span a range of 8.6%. The need for an independent time calibration emerged with use of the current data acquisition software (Zhao et al., Anal. Biochem., 437 (2013) 104-108), and we now show that smaller but significant time errors of up to 2% also occur with earlier versions. After application of these calibration corrections, the sedimentation coefficients obtained from 11 instruments displayed a significantly reduced standard deviation of approximately 0.7%. This study demonstrates the need for external calibration procedures and regular control experiments with a sedimentation coefficient standard. Published by Elsevier Inc.

  5. Mathematical Model and Calibration Procedure of a PSD Sensor Used in Local Positioning Systems.

    PubMed

    Rodríguez-Navarro, David; Lázaro-Galilea, José Luis; Bravo-Muñoz, Ignacio; Gardel-Vicente, Alfredo; Domingo-Perez, Francisco; Tsirigotis, Georgios

    2016-09-15

    Here, we propose a mathematical model and a calibration procedure for a PSD (position sensitive device) sensor equipped with an optical system, to enable accurate measurement of the angle of arrival of one or more beams of light emitted by infrared (IR) transmitters located at distances of between 4 and 6 m. To achieve this objective, it was necessary to characterize the intrinsic parameters that model the system and obtain their values. This first approach was based on a pin-hole model, to which system nonlinearities were added, and this was used to model the points obtained with the nA currents provided by the PSD. In addition, we analyzed the main sources of error, including PSD sensor signal noise, gain factor imbalances and PSD sensor distortion. The results indicated that the proposed model and method provided satisfactory calibration and yielded precise parameter values, enabling accurate measurement of the angle of arrival with a low degree of error, as evidenced by the experimental results.

  6. Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current.

    PubMed

    Choleau, C; Klein, J C; Reach, G; Aussedat, B; Demaria-Pesce, V; Wilson, G S; Gifford, R; Ward, W K

    2002-08-01

    The calibration of a continuous glucose monitoring system, i.e. the transformation of the signal I(t) generated by the glucose sensor at time (t) into an estimation of glucose concentration G(t), represents a key issue. The two-point calibration procedure consists of the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The estimation of G(t) is subsequently given by G(t) = (I(t)-I(o))/S. A glucose sensor was implanted in the subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). For each individual trial, S and I(o) were determined by taking into account the values of two sets of sensor output and blood glucose concentration distant by at least 1 h, the procedure being repeated for each consecutive set of values. S and I(o) were found to be negatively correlated, the value of I(o) being sometimes negative. Theoretical analysis demonstrates that this phenomenon can be explained by the effect of measurement uncertainties on the determination of capillary glucose concentration and of sensor output.

  7. A novel calibration method for non-orthogonal shaft laser theodolite measurement system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Bin, E-mail: wubin@tju.edu.cn, E-mail: xueting@tju.edu.cn; Yang, Fengting; Ding, Wen

    2016-03-15

    Non-orthogonal shaft laser theodolite (N-theodolite) is a new kind of large-scale metrological instrument made up by two rotary tables and one collimated laser. There are three axes for an N-theodolite. According to naming conventions in traditional theodolite, rotary axes of two rotary tables are called as horizontal axis and vertical axis, respectively, and the collimated laser beam is named as sight axis. And the difference between N-theodolite and traditional theodolite is obvious, since the former one with no orthogonal and intersecting accuracy requirements. So the calibration method for traditional theodolite is no longer suitable for N-theodolite, while the calibration methodmore » applied currently is really complicated. Thus this paper introduces a novel calibration method for non-orthogonal shaft laser theodolite measurement system to simplify the procedure and to improve the calibration accuracy. A simple two-step process, calibration for intrinsic parameters and for extrinsic parameters, is proposed by the novel method. And experiments have shown its efficiency and accuracy.« less

  8. A calibration-free electrode compensation method

    PubMed Central

    Rossant, Cyrille; Fontaine, Bertrand; Magnusson, Anna K.

    2012-01-01

    In a single-electrode current-clamp recording, the measured potential includes both the response of the membrane and that of the measuring electrode. The electrode response is traditionally removed using bridge balance, where the response of an ideal resistor representing the electrode is subtracted from the measurement. Because the electrode is not an ideal resistor, this procedure produces capacitive transients in response to fast or discontinuous currents. More sophisticated methods exist, but they all require a preliminary calibration phase, to estimate the properties of the electrode. If these properties change after calibration, the measurements are corrupted. We propose a compensation method that does not require preliminary calibration. Measurements are compensated offline by fitting a model of the neuron and electrode to the trace and subtracting the predicted electrode response. The error criterion is designed to avoid the distortion of compensated traces by spikes. The technique allows electrode properties to be tracked over time and can be extended to arbitrary models of electrode and neuron. We demonstrate the method using biophysical models and whole cell recordings in cortical and brain-stem neurons. PMID:22896724

  9. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence ofmore » Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.« less

  10. Calibration Of Partial-Pressure-Of-Oxygen Sensors

    NASA Technical Reports Server (NTRS)

    Yount, David W.; Heronimus, Kevin

    1995-01-01

    Report and analysis of, and discussion of improvements in, procedure for calibrating partial-pressure-of-oxygen sensors to satisfy Spacelab calibration requirements released. Sensors exhibit fast drift, which results in short calibration period not suitable for Spacelab. By assessing complete process of determining total drift range available, calibration procedure modified to eliminate errors and still satisfy requirements without compromising integrity of system.

  11. High-precision reflectivity measurements: improvements in the calibration procedure

    NASA Astrophysics Data System (ADS)

    Jupe, Marco; Grossmann, Florian; Starke, Kai; Ristau, Detlev

    2003-05-01

    The development of high quality optical components is heavily depending on precise characterization procedures. The reflectance and transmittance of laser components are the most important parameters for advanced laser applications. In the industrial fabrication of optical coatings, quality management is generally insured by spectral photometric methods according to ISO/DIS 15386 on a medium level of accuracy. Especially for high reflecting mirrors, a severe discrepancy in the determination of the absolute reflectivity can be found for spectral photometric procedures. In the first part of the CHOCLAB project, a method for measuring reflectance and transmittance with an enhanced precision was developed, which is described in ISO/WD 13697. In the second part of the CHOCLAB project, the evaluation and optimization for the presented method is scheduled. Within this framework international Round-Robin experiment is currently in progress. During this Round-Robin experiment, distinct deviations could be observed between the results of high precision measurement facilities of different partners. Based on the extended experiments, the inhomogeneity of the sample reflectivity was identified as one important origin for the deviation. Consequently, this inhomogeneity is also influencing the calibration procedure. Therefore, a method was developed that allows the calibration of the chopper blade using always the same position on the reference mirror. During the investigations, the homogeneity of several samples was characterized by a surface mapping procedure for 1064 nm. The measurement facility was extended to the additional wavelength 532 nm and a similar set-up was assembled at 10.6 μm. The high precision reflectivity procedure at the mentioned wavelengths is demonstrated for exemplary measurements.

  12. ASRDI oxygen technology survey. Volume 8: Pressure measurement

    NASA Technical Reports Server (NTRS)

    Arvidson, J. M.; Brennan, J. A.

    1975-01-01

    Pressure transducers and their current uses with gaseous or liquid oxygen are reviewed. All transducer types such as strain gage, capacitance, potentiometric, piezoelectric, etc., are included. Topics covered include: cryogenic pressure measurement; material compatibility with gaseous and liquid oxygen; cleaning procedures; pressure tap connections; transducer types and descriptions; and calibration techniques.

  13. Experimental calibration procedures for rotating Lorentz-force flowmeters

    DOE PAGES

    Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; ...

    2017-07-14

    Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.

  14. Experimental calibration procedures for rotating Lorentz-force flowmeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hvasta, M. G.; Slighton, N. T.; Kolemen, E.

    Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.

  15. Improving Photometric Calibration of Meteor Video Camera Systems

    NASA Technical Reports Server (NTRS)

    Ehlert, Steven; Kingery, Aaron; Cooke, William

    2016-01-01

    Current optical observations of meteors are commonly limited by systematic uncertainties in photometric calibration at the level of approximately 0.5 mag or higher. Future improvements to meteor ablation models, luminous efficiency models, or emission spectra will hinge on new camera systems and techniques that significantly reduce calibration uncertainties and can reliably perform absolute photometric measurements of meteors. In this talk we discuss the algorithms and tests that NASA's Meteoroid Environment Office (MEO) has developed to better calibrate photometric measurements for the existing All-Sky and Wide-Field video camera networks as well as for a newly deployed four-camera system for measuring meteor colors in Johnson-Cousins BV RI filters. In particular we will emphasize how the MEO has been able to address two long-standing concerns with the traditional procedure, discussed in more detail below.

  16. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR HARVARD PM IMPACTOR CALIBRATION AND LEAK TESTING (UA-L-7.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR HARVARD PM IMPACTOR CALIBRATION AND LEAK TESTING (UA-L-7.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...

  18. The in-flight calibration of the Hubble Space Telescope attitude sensors

    NASA Technical Reports Server (NTRS)

    Welter, Gary L.

    1991-01-01

    A detailed review of the in-flight calibration of the Hubble Space Telescope attitude sensors is presented. The review, which covers the period from the April 24, 1990, launch of the spacecraft until the time of this writing (June 1991), describes the calibrations required and accuracies achieved for the four principal attitude sensing systems on the spacecraft: the magnetometers, the fixed head star trackers, the gyroscopes, and the fine guidance sensors (FGS's). In contrast to the other three sensor groups, the Hubble Telecope's FGS's are unique in the precision and performance levels being attempted; spacecraft control and astrometric research at the near-milliarcsecond level are the ultimate goals. FGS calibration accuracies at the 20-milliarcsecond level have already been achieved, and plans for new data acquisitions and reductions that should substantially improve these results are in progress. A summary of the basic attributes of each of the four sensor groups with respect to its usage as an attitude measuring system is presented, followed by a discussion of the calibration items of interest for that group. The calibration items are as follows: for the magnetometers, the corrections for the spacecraft's static and time-varying magnetic fields; for the fixed-head star trackers, their relative alignments and use in performing onboard attitude updates; for the gyroscopes, their scale factors, alignments, and drift rate biases; and for the FGS's, their magnifications, optical distortions, and alignments. The discussion covers the procedures used for each calibration, as well as the order of the calibrations within the general flow of orbital verification activities. It also includes a synopsis of current plans for the eventual calibration of the FGS's to achieve their near-milliarcsecond design accuracy. The conclusions include a table indicating the current and predicted ultimate accuracies for each of the calibration items.

  19. A BPM calibration procedure using TBT data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, M.J.; Crisp, J.; Prieto, P.

    2007-06-01

    Accurate BPM calibration is crucial for lattice analysis. It is also reassuring when the calibration can be independently verified. This paper outlines a procedure that can extract BPM calibration information from TBT orbit data. The procedure is developed as an extension to the Turn-By-Turn lattice analysis [1]. Its application to data from both Recycler Ring and Main Injector (MI) at Fermilab have produced very encouraging results. Some specifics in hardware design will be mentioned to contrast that of analysis results.

  20. Radiometrie recalibration procedure for landsat-5 thematic mapper data

    USGS Publications Warehouse

    Chander, G.; Micijevic, E.; Hayes, R.W.; Barsi, J.A.

    2008-01-01

    The Landsat-5 (L5) satellite was launched on March 01, 1984, with a design life of three years. Incredibly, the L5 Thematic Mapper (TM) has collected data for 23 years. Over this time, the detectors have aged, and its radiometric characteristics have changed since launch. The calibration procedures and parameters have also changed with time. Revised radiometric calibrations have improved the radiometric accuracy of recently processed data; however, users with data that were processed prior to the calibration update do not benefit from the revisions. A procedure has been developed to give users the ability to recalibrate their existing Level 1 (L1) products without having to purchase reprocessed data from the U.S. Geological Survey (USGS). The accuracy of the recalibration is dependent on the knowledge of the prior calibration applied to the data. The ""Work Order" file, included with standard National Land Archive Production System (NLAFS) data products, gives parameters that define the applied calibration. These are the Internal Calibrator (IC) calibration parameters or the default prelaunch calibration, if there were problems with the IC calibration. This paper details the recalibration procedure for data processed using IC, in which users have the Work Order file. ?? 2001 IEEE.

  1. APEX/SPIN: a free test platform to measure speech intelligibility.

    PubMed

    Francart, Tom; Hofmann, Michael; Vanthornhout, Jonas; Van Deun, Lieselot; van Wieringen, Astrid; Wouters, Jan

    2017-02-01

    Measuring speech intelligibility in quiet and noise is important in clinical practice and research. An easy-to-use free software platform for conducting speech tests is presented, called APEX/SPIN. The APEX/SPIN platform allows the use of any speech material in combination with any noise. A graphical user interface provides control over a large range of parameters, such as number of loudspeakers, signal-to-noise ratio and parameters of the procedure. An easy-to-use graphical interface is provided for calibration and storage of calibration values. To validate the platform, perception of words in quiet and sentences in noise were measured both with APEX/SPIN and with an audiometer and CD player, which is a conventional setup in current clinical practice. Five normal-hearing listeners participated in the experimental evaluation. Speech perception results were similar for the APEX/SPIN platform and conventional procedures. APEX/SPIN is a freely available and open source platform that allows the administration of all kinds of custom speech perception tests and procedures.

  2. Representing operations procedures using temporal dependency networks

    NASA Technical Reports Server (NTRS)

    Fayyad, Kristina E.; Cooper, Lynne P.

    1993-01-01

    DSN Link Monitor & Control (LMC) operations consist primarily of executing procedures to configure, calibrate, test, and operate a communications link between an interplanetary spacecraft and its mission control center. Currently the LMC operators are responsible for integrating procedures into an end-to-end series of steps. The research presented in this paper is investigating new ways of specifying operations procedures that incorporate the insight of operations, engineering, and science personnel to improve mission operations. The paper describes the rationale for using Temporal Dependency Networks (TDN's) to represent the procedures, a description of how the data is acquired, and the knowledge engineering effort required to represent operations procedures. Results of operational tests of this concept, as implemented in the LMC Operator Assistant Prototype (LMCOA), are also presented.

  3. Calibration of steady-state car-following models using macroscopic loop detector data.

    DOT National Transportation Integrated Search

    2010-05-01

    The paper develops procedures for calibrating the steady-state component of various car following models using : macroscopic loop detector data. The calibration procedures are developed for a number of commercially available : microscopic traffic sim...

  4. Calibration procedure for a laser triangulation scanner with uncertainty evaluation

    NASA Astrophysics Data System (ADS)

    Genta, Gianfranco; Minetola, Paolo; Barbato, Giulio

    2016-11-01

    Most of low cost 3D scanning devices that are nowadays available on the market are sold without a user calibration procedure to correct measurement errors related to changes in environmental conditions. In addition, there is no specific international standard defining a procedure to check the performance of a 3D scanner along time. This paper aims at detailing a thorough methodology to calibrate a 3D scanner and assess its measurement uncertainty. The proposed procedure is based on the use of a reference ball plate and applied to a triangulation laser scanner. Experimental results show that the metrological performance of the instrument can be greatly improved by the application of the calibration procedure that corrects systematic errors and reduces the device's measurement uncertainty.

  5. Risk prediction models for major adverse cardiac event (MACE) following percutaneous coronary intervention (PCI): A review

    NASA Astrophysics Data System (ADS)

    Manan, Norhafizah A.; Abidin, Basir

    2015-02-01

    Five percent of patients who went through Percutaneous Coronary Intervention (PCI) experienced Major Adverse Cardiac Events (MACE) after PCI procedure. Risk prediction of MACE following a PCI procedure therefore is helpful. This work describes a review of such prediction models currently in use. Literature search was done on PubMed and SCOPUS database. Thirty literatures were found but only 4 studies were chosen based on the data used, design, and outcome of the study. Particular emphasis was given and commented on the study design, population, sample size, modeling method, predictors, outcomes, discrimination and calibration of the model. All the models had acceptable discrimination ability (C-statistics >0.7) and good calibration (Hosmer-Lameshow P-value >0.05). Most common model used was multivariate logistic regression and most popular predictor was age.

  6. Methods for Calibration of Prout-Tompkins Kinetics Parameters Using EZM Iteration and GLO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wemhoff, A P; Burnham, A K; de Supinski, B

    2006-11-07

    This document contains information regarding the standard procedures used to calibrate chemical kinetics parameters for the extended Prout-Tompkins model to match experimental data. Two methods for calibration are mentioned: EZM calibration and GLO calibration. EZM calibration matches kinetics parameters to three data points, while GLO calibration slightly adjusts kinetic parameters to match multiple points. Information is provided regarding the theoretical approach and application procedure for both of these calibration algorithms. It is recommended that for the calibration process, the user begin with EZM calibration to provide a good estimate, and then fine-tune the parameters using GLO. Two examples have beenmore » provided to guide the reader through a general calibrating process.« less

  7. Special features of the dayCent modeling package and additional procedures for parameterization, calibration, validation, and applications

    USDA-ARS?s Scientific Manuscript database

    DayCent (Daily Century) is a biogeochemical model of intermediate complexity used to simulate flows of carbon and nutrients for crop, grassland, forest, and savanna ecosystems. Required model inputs are: soil texture, current and historical land use, vegetation cover, and daily maximum/minimum tempe...

  8. Calibration of collection procedures for the determination of precipitation chemistry

    Treesearch

    James N. Galloway; Gene E. Likens

    1976-01-01

    Precipitation is currently collected by several methods, including several different designs of collection apparatus. We are investigating these differing methods and designs to determine which gives the most representative sample of precipitation for the analysis of some 25 chemical parameters. The experimental site, located in Ithaca, New York, has 22 collectors of...

  9. On the use of mobile phones and wearable microphones for noise exposure measurements: Calibration and measurement accuracy

    NASA Astrophysics Data System (ADS)

    Dumoulin, Romain

    Despite the fact that noise-induced hearing loss remains the number one occupational disease in developed countries, individual noise exposure levels are still rarely known and infrequently tracked. Indeed, efforts to standardize noise exposure levels present disadvantages such as costly instrumentation and difficulties associated with on site implementation. Given their advanced technical capabilities and widespread daily usage, mobile phones could be used to measure noise levels and make noise monitoring more accessible. However, the use of mobile phones for measuring noise exposure is currently limited due to the lack of formal procedures for their calibration and challenges regarding the measurement procedure. Our research investigated the calibration of mobile phone-based solutions for measuring noise exposure using a mobile phone's built-in microphones and wearable external microphones. The proposed calibration approach integrated corrections that took into account microphone placement error. The corrections were of two types: frequency-dependent, using a digital filter and noise level-dependent, based on the difference between the C-weighted noise level minus A-weighted noise level of the noise measured by the phone. The electro-acoustical limitations and measurement calibration procedure of the mobile phone were investigated. The study also sought to quantify the effect of noise exposure characteristics on the accuracy of calibrated mobile phone measurements. Measurements were carried out in reverberant and semi-anechoic chambers with several mobiles phone units of the same model, two types of external devices (an earpiece and a headset with an in-line microphone) and an acoustical test fixture (ATF). The proposed calibration approach significantly improved the accuracy of the noise level measurements in diffuse and free fields, with better results in the diffuse field and with ATF positions causing little or no acoustic shadowing. Several sources of errors and uncertainties were identified including the errors associated with the inter-unit-variability, the presence of signal saturation and the microphone placement relative to the source and the wearer. The results of the investigations and validation measurements led to recommendations regarding the measurement procedure including the use of external microphones having lower sensitivity and provided the basis for a standardized and unique factory default calibration method intended for implementation in any mobile phone. A user-defined adjustment was proposed to minimize the errors associated with calibration and the acoustical field. Mobile phones implementing the proposed laboratory calibration and used with external microphones showed great potential as noise exposure instruments. Combined with their potential as training and prevention tools, the expansion of their use could significantly help reduce the risks of noise-induced hearing loss.

  10. Development of a new calibration procedure and its experimental validation applied to a human motion capture system.

    PubMed

    Royo Sánchez, Ana Cristina; Aguilar Martín, Juan José; Santolaria Mazo, Jorge

    2014-12-01

    Motion capture systems are often used for checking and analyzing human motion in biomechanical applications. It is important, in this context, that the systems provide the best possible accuracy. Among existing capture systems, optical systems are those with the highest accuracy. In this paper, the development of a new calibration procedure for optical human motion capture systems is presented. The performance and effectiveness of that new calibration procedure are also checked by experimental validation. The new calibration procedure consists of two stages. In the first stage, initial estimators of intrinsic and extrinsic parameters are sought. The camera calibration method used in this stage is the one proposed by Tsai. These parameters are determined from the camera characteristics, the spatial position of the camera, and the center of the capture volume. In the second stage, a simultaneous nonlinear optimization of all parameters is performed to identify the optimal values, which minimize the objective function. The objective function, in this case, minimizes two errors. The first error is the distance error between two markers placed in a wand. The second error is the error of position and orientation of the retroreflective markers of a static calibration object. The real co-ordinates of the two objects are calibrated in a co-ordinate measuring machine (CMM). The OrthoBio system is used to validate the new calibration procedure. Results are 90% lower than those from the previous calibration software and broadly comparable with results from a similarly configured Vicon system.

  11. Line fiducial material and thickness considerations for ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower echogenicity are more accurately segmented in comparison to highly reflective thin phantoms. This improvement in segmentation accuracy leads to a lower fiducial localization error, which ultimately results in low target registration error. This would have a profound effect on calibration procedures and the feasibility of different calibration procedures in the context of image-guided procedures.

  12. Evaluation of Airborne Visible/Infrared Imaging Spectrometer Data of the Mountain Pass, California carbonatite complex

    NASA Technical Reports Server (NTRS)

    Crowley, James; Rowan, Lawrence; Podwysocki, Melvin; Meyer, David

    1988-01-01

    Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of the Mountain Pass, California carbonatite complex were examined to evaluate the AVIRIS instrument performance and to explore alternative methods of data calibration. Although signal-to-noise estimates derived from the data indicated that the A, B, and C spectrometers generally met the original instrument design objectives, the S/N performance of the D spectrometer was below expectations. Signal-to-noise values of 20 to 1 or lower were typical of the D spectrometer and several detectors in the D spectrometer array were shown to have poor electronic stability. The AVIRIS data also exhibited periodic noise, and were occasionally subject to abrupt dark current offsets. Despite these limitations, a number of mineral absorption bands, including CO3, Al-OH, and unusual rare earth element bands, were observed for mine areas near the main carbonatite body. To discern these bands, two different calibration procedures were applied to remove atmospheric and solar components from the remote sensing data. The two procedures, referred to as the single spectrum and the flat field calibration methods gave distinctly different results. In principle, the single spectrum method should be more accurate; however, additional fieldwork is needed to rigorously determine the degree of calibration success.

  13. Multi-sensor calibration of low-cost magnetic, angular rate and gravity systems.

    PubMed

    Lüken, Markus; Misgeld, Berno J E; Rüschen, Daniel; Leonhardt, Steffen

    2015-10-13

    We present a new calibration procedure for low-cost nine degrees-of-freedom (9DOF) magnetic, angular rate and gravity (MARG) sensor systems, which relies on a calibration cube, a reference table and a body sensor network (BSN). The 9DOF MARG sensor is part of our recently-developed "Integrated Posture and Activity Network by Medit Aachen" (IPANEMA) BSN. The advantage of this new approach is the use of the calibration cube, which allows for easy integration of two sensor nodes of the IPANEMA BSN. One 9DOF MARG sensor node is thereby used for calibration; the second 9DOF MARG sensor node is used for reference measurements. A novel algorithm uses these measurements to further improve the performance of the calibration procedure by processing arbitrarily-executed motions. In addition, the calibration routine can be used in an alignment procedure to minimize errors in the orientation between the 9DOF MARG sensor system and a motion capture inertial reference system. A two-stage experimental study is conducted to underline the performance of our calibration procedure. In both stages of the proposed calibration procedure, the BSN data, as well as reference tracking data are recorded. In the first stage, the mean values of all sensor outputs are determined as the absolute measurement offset to minimize integration errors in the derived movement model of the corresponding body segment. The second stage deals with the dynamic characteristics of the measurement system where the dynamic deviation of the sensor output compared to a reference system is Sensors 2015, 15 25920 corrected. In practical validation experiments, this procedure showed promising results with a maximum RMS error of 3.89°.

  14. Multi-Sensor Calibration of Low-Cost Magnetic, Angular Rate and Gravity Systems

    PubMed Central

    Lüken, Markus; Misgeld, Berno J.E.; Rüschen, Daniel; Leonhardt, Steffen

    2015-01-01

    We present a new calibration procedure for low-cost nine degrees-of-freedom (9DOF) magnetic, angular rate and gravity (MARG) sensor systems, which relies on a calibration cube, a reference table and a body sensor network (BSN). The 9DOF MARG sensor is part of our recently-developed “Integrated Posture and Activity Network by Medit Aachen” (IPANEMA) BSN. The advantage of this new approach is the use of the calibration cube, which allows for easy integration of two sensor nodes of the IPANEMA BSN. One 9DOF MARG sensor node is thereby used for calibration; the second 9DOF MARG sensor node is used for reference measurements. A novel algorithm uses these measurements to further improve the performance of the calibration procedure by processing arbitrarily-executed motions. In addition, the calibration routine can be used in an alignment procedure to minimize errors in the orientation between the 9DOF MARG sensor system and a motion capture inertial reference system. A two-stage experimental study is conducted to underline the performance of our calibration procedure. In both stages of the proposed calibration procedure, the BSN data, as well as reference tracking data are recorded. In the first stage, the mean values of all sensor outputs are determined as the absolute measurement offset to minimize integration errors in the derived movement model of the corresponding body segment. The second stage deals with the dynamic characteristics of the measurement system where the dynamic deviation of the sensor output compared to a reference system is corrected. In practical validation experiments, this procedure showed promising results with a maximum RMS error of 3.89°. PMID:26473873

  15. Landsat-5 TM reflective-band absolute radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Helder, D.L.; Markham, B.L.; Dewald, J.D.; Kaita, E.; Thome, K.J.; Micijevic, E.; Ruggles, T.A.

    2004-01-01

    The Landsat-5 Thematic Mapper (TM) sensor provides the longest running continuous dataset of moderate spatial resolution remote sensing imagery, dating back to its launch in March 1984. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset of each detector. Due to observed degradations in the IC, a new procedure was implemented for U.S.-processed data in May 2003. This new calibration procedure is based on a lifetime radiometric calibration model for the instrument's reflective bands (1-5 and 7) and is derived, in part, from the IC response without the related degradation effects and is tied to the cross calibration with the Landsat-7 Enhanced Thematic Mapper Plus. Reflective-band absolute radiometric accuracy of the instrument tends to be on the order of 7% to 10%, based on a variety of calibration methods.

  16. IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use.

    PubMed

    Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders

    2017-02-01

    Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Energy calibration issues in nuclear resonant vibrational spectroscopy: observing small spectral shifts and making fast calibrations.

    PubMed

    Wang, Hongxin; Yoda, Yoshitaka; Dong, Weibing; Huang, Songping D

    2013-09-01

    The conventional energy calibration for nuclear resonant vibrational spectroscopy (NRVS) is usually long. Meanwhile, taking NRVS samples out of the cryostat increases the chance of sample damage, which makes it impossible to carry out an energy calibration during one NRVS measurement. In this study, by manipulating the 14.4 keV beam through the main measurement chamber without moving out the NRVS sample, two alternative calibration procedures have been proposed and established: (i) an in situ calibration procedure, which measures the main NRVS sample at stage A and the calibration sample at stage B simultaneously, and calibrates the energies for observing extremely small spectral shifts; for example, the 0.3 meV energy shift between the 100%-(57)Fe-enriched [Fe4S4Cl4](=) and 10%-(57)Fe and 90%-(54)Fe labeled [Fe4S4Cl4](=) has been well resolved; (ii) a quick-switching energy calibration procedure, which reduces each calibration time from 3-4 h to about 30 min. Although the quick-switching calibration is not in situ, it is suitable for normal NRVS measurements.

  18. NASA Glenn Icing Research Tunnel: 2014 and 2015 Cloud Calibration Procedures and Results

    NASA Technical Reports Server (NTRS)

    Steen, Laura E.; Ide, Robert F.; Van Zante, Judith F.; Acosta, Waldo J.

    2015-01-01

    This report summarizes the current status of the NASA Glenn Research Center (GRC) Icing Research Tunnel cloud calibration: specifically, the cloud uniformity, liquid water content, and drop-size calibration results from both the January-February 2014 full cloud calibration and the January 2015 interim cloud calibration. Some aspects of the cloud have remained the same as what was reported for the 2014 full calibration, including the cloud uniformity from the Standard nozzles, the drop-size equations for Standard and Mod1 nozzles, and the liquid water content for large-drop conditions. Overall, the tests performed in January 2015 showed good repeatability to 2014, but there is new information to report as well. There have been minor updates to the Mod1 cloud uniformity on the north side of the test section. Also, successful testing with the OAP-230Y has allowed the IRT to re-expand its operating envelopes for large-drop conditions to a maximum median volumetric diameter of 270 microns. Lastly, improvements to the collection-efficiency correction for the SEA multi-wire have resulted in new calibration equations for Standard- and Mod1-nozzle liquid water content.

  19. Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

    NASA Technical Reports Server (NTRS)

    Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.

    2010-01-01

    Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

  20. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    PubMed

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  1. New Method of Calibrating IRT Models.

    ERIC Educational Resources Information Center

    Jiang, Hai; Tang, K. Linda

    This discussion of new methods for calibrating item response theory (IRT) models looks into new optimization procedures, such as the Genetic Algorithm (GA) to improve on the use of the Newton-Raphson procedure. The advantages of using a global optimization procedure like GA is that this kind of procedure is not easily affected by local optima and…

  2. Step wise, multiple objective calibration of a hydrologic model for a snowmelt dominated basin

    USGS Publications Warehouse

    Hay, L.E.; Leavesley, G.H.; Clark, M.P.; Markstrom, S.L.; Viger, R.J.; Umemoto, M.

    2006-01-01

    The ability to apply a hydrologic model to large numbers of basins for forecasting purposes requires a quick and effective calibration strategy. This paper presents a step wise, multiple objective, automated procedure for hydrologic model calibration. This procedure includes the sequential calibration of a model's simulation of solar radiation (SR), potential evapotranspiration (PET), water balance, and daily runoff. The procedure uses the Shuffled Complex Evolution global search algorithm to calibrate the U.S. Geological Survey's Precipitation Runoff Modeling System in the Yampa River basin of Colorado. This process assures that intermediate states of the model (SR and PET on a monthly mean basis), as well as the water balance and components of the daily hydrograph are simulated, consistently with measured values.

  3. A novel method for determining calibration and behavior of PVDF ultrasonic hydrophone probes in the frequency range up to 100 MHz.

    PubMed

    Bleeker, H J; Lewin, P A

    2000-01-01

    A new calibration technique for PVDF ultrasonic hydrophone probes is described. Current implementation of the technique allows determination of hydrophone frequency response between 2 and 100 MHz and is based on the comparison of theoretically predicted and experimentally determined pressure-time waveforms produced by a focused, circular source. The simulation model was derived from the time domain algorithm that solves the non linear KZK (Khokhlov-Zabolotskaya-Kuznetsov) equation describing acoustic wave propagation. The calibration technique data were experimentally verified using independent calibration procedures in the frequency range from 2 to 40 MHz using a combined time delay spectrometry and reciprocity approach or calibration data provided by the National Physical Laboratory (NPL), UK. The results of verification indicated good agreement between the results obtained using KZK and the above-mentioned independent calibration techniques from 2 to 40 MHz, with the maximum discrepancy of 18% at 30 MHz. The frequency responses obtained using different hydrophone designs, including several membrane and needle probes, are presented, and it is shown that the technique developed provides a desirable tool for independent verification of primary calibration techniques such as those based on optical interferometry. Fundamental limitations of the presented calibration method are also examined.

  4. Calibration of 3D ultrasound to an electromagnetic tracking system

    NASA Astrophysics Data System (ADS)

    Lang, Andrew; Parthasarathy, Vijay; Jain, Ameet

    2011-03-01

    The use of electromagnetic (EM) tracking is an important guidance tool that can be used to aid procedures requiring accurate localization such as needle injections or catheter guidance. Using EM tracking, the information from different modalities can be easily combined using pre-procedural calibration information. These calibrations are performed individually, per modality, allowing different imaging systems to be mixed and matched according to the procedure at hand. In this work, a framework for the calibration of a 3D transesophageal echocardiography probe to EM tracking is developed. The complete calibration framework includes three required steps: data acquisition, needle segmentation, and calibration. Ultrasound (US) images of an EM tracked needle must be acquired with the position of the needles in each volume subsequently extracted by segmentation. The calibration transformation is determined through a registration between the segmented points and the recorded EM needle positions. Additionally, the speed of sound is compensated for since calibration is performed in water that has a different speed then is assumed by the US machine. A statistical validation framework has also been developed to provide further information related to the accuracy and consistency of the calibration. Further validation of the calibration showed an accuracy of 1.39 mm.

  5. An automatic calibration procedure for remote eye-gaze tracking systems.

    PubMed

    Model, Dmitri; Guestrin, Elias D; Eizenman, Moshe

    2009-01-01

    Remote gaze estimation systems use calibration procedures to estimate subject-specific parameters that are needed for the calculation of the point-of-gaze. In these procedures, subjects are required to fixate on a specific point or points at specific time instances. Advanced remote gaze estimation systems can estimate the optical axis of the eye without any personal calibration procedure, but use a single calibration point to estimate the angle between the optical axis and the visual axis (line-of-sight). This paper presents a novel automatic calibration procedure that does not require active user participation. To estimate the angles between the optical and visual axes of each eye, this procedure minimizes the distance between the intersections of the visual axes of the left and right eyes with the surface of a display while subjects look naturally at the display (e.g., watching a video clip). Simulation results demonstrate that the performance of the algorithm improves as the range of viewing angles increases. For a subject sitting 75 cm in front of an 80 cm x 60 cm display (40" TV) the standard deviation of the error in the estimation of the angles between the optical and visual axes is 0.5 degrees.

  6. SPRT Calibration Uncertainties and Internal Quality Control at a Commercial SPRT Calibration Facility

    NASA Astrophysics Data System (ADS)

    Wiandt, T. J.

    2008-06-01

    The Hart Scientific Division of the Fluke Corporation operates two accredited standard platinum resistance thermometer (SPRT) calibration facilities, one at the Hart Scientific factory in Utah, USA, and the other at a service facility in Norwich, UK. The US facility is accredited through National Voluntary Laboratory Accreditation Program (NVLAP), and the UK facility is accredited through UKAS. Both provide SPRT calibrations using similar equipment and procedures, and at similar levels of uncertainty. These uncertainties are among the lowest available commercially. To achieve and maintain low uncertainties, it is required that the calibration procedures be thorough and optimized. However, to minimize customer downtime, it is also important that the instruments be calibrated in a timely manner and returned to the customer. Consequently, subjecting the instrument to repeated calibrations or extensive repeated measurements is not a viable approach. Additionally, these laboratories provide SPRT calibration services involving a wide variety of SPRT designs. These designs behave differently, yet predictably, when subjected to calibration measurements. To this end, an evaluation strategy involving both statistical process control and internal consistency measures is utilized to provide confidence in both the instrument calibration and the calibration process. This article describes the calibration facilities, procedure, uncertainty analysis, and internal quality assurance measures employed in the calibration of SPRTs. Data will be reviewed and generalities will be presented. Finally, challenges and considerations for future improvements will be discussed.

  7. STIS Data Handbook v. 6.0

    NASA Astrophysics Data System (ADS)

    Bostroem, K. A.; Proffitt, C.

    2011-05-01

    This handbook describes data from the Space Telescope Imaging Spectrograph (STIS) onboard the Hubble Space Telescope (HST), and how to manipulate, calibrate, and analyze those data. The current version of the STIS Data Handbook is presented as an independent and self-contained document, extensively built on the contents of version 6 of the HST Data Handbook. Users are referred to a companion volume, Introduction to the HST Data Handbooks, for more general information about the details of acquiring data from the HST archive, HST file formats, and general purpose software for displaying and processing HST data. For detailed information on the capabilities of the instrument, and how to plan observations, users should refer to the STIS Instrument Handbook. For further information and timely updates, users should consult the STIS Web page (http://www.stsci.edu/hst/stis), especially the Document Archive link. In particular, the STScI Analysis Newsletters (STANs) highlight changes in code and calibration procedures and provide other instrument-related news. The Instrument Science Reports (ISRs) present in-depth characterizations of the instrument and detailed explanations of calibration code and procedures. The current edition of the STIS Data Handbook was completed in early-2011. The last major revision was published in January 2002, following the failure of the Side-1 electronics and the successful resumption of operations using Side-2 electronics in the summer of 2001. STIS continued to perform well until the Side-2 electronics failed on 3 August 2004. STIS was successfully repaired during the fourth HST servicing mission (SM4) in May 2009 and has resumed science operations with all channels. A static archive of all STIS data taken prior to the Side-2 failure was prepared in 2006 using the latest calibration code and reference files, and has now replaced On-the-Fly Reprocessing (OTFR) of STIS data. At that time, substantial improvements were made to calibration and pipeline codes and reference files (see Section 1.5). New STIS data taken after the 2009 repair will be processed through OTFR when requested from the HST archive. This will allow the data to be calibrated with the most up-to-date versions of the software and reference files.

  8. Development of an in situ calibration technique for combustible gas detectors

    NASA Technical Reports Server (NTRS)

    Shumar, J. W.; Wynveen, R. A.; Lance, N., Jr.; Lantz, J. B.

    1977-01-01

    This paper describes the development of an in situ calibration procedure for combustible gas detectors (CGD). The CGD will be a necessary device for future space vehicles as many subsystems in the Environmental Control/Life Support System utilize or produce hydrogen (H2) gas. Existing calibration techniques are time-consuming and require support equipment such as an environmental chamber and calibration gas supply. The in situ calibration procedure involves utilization of a water vapor electrolysis cell for the automatic in situ generation of a H2/air calibration mixture within the flame arrestor of the CGD. The development effort concluded with the successful demonstration of in situ span calibrations of a CGD.

  9. Automation is an Effective Way to Improve Quality of Verification (Calibration) of Measuring Instruments

    NASA Astrophysics Data System (ADS)

    Golobokov, M.; Danilevich, S.

    2018-04-01

    In order to assess calibration reliability and automate such assessment, procedures for data collection and simulation study of thermal imager calibration procedure have been elaborated. The existing calibration techniques do not always provide high reliability. A new method for analyzing the existing calibration techniques and developing new efficient ones has been suggested and tested. A type of software has been studied that allows generating instrument calibration reports automatically, monitoring their proper configuration, processing measurement results and assessing instrument validity. The use of such software allows reducing man-hours spent on finalization of calibration data 2 to 5 times and eliminating a whole set of typical operator errors.

  10. Standardization of gamma-glutamyltransferase assays by intermethod calibration. Effect on determining common reference limits.

    PubMed

    Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph

    2007-01-01

    The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.

  11. A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer.

    PubMed

    Pagoulatos, N; Haynor, D R; Kim, Y

    2001-09-01

    We have developed a fast calibration method for computing the position and orientation of 2-D ultrasound (US) images in 3-D space where a position sensor is mounted on the US probe. This calibration is required in the fields of 3-D ultrasound and registration of ultrasound with other imaging modalities. Most of the existing calibration methods require a complex and tedious experimental procedure. Our method is simple and it is based on a custom-built phantom. Thirty N-fiducials (markers in the shape of the letter "N") embedded in the phantom provide the basis for our calibration procedure. We calibrated a 3.5-MHz sector phased-array probe with a magnetic position sensor, and we studied the accuracy and precision of our method. A typical calibration procedure requires approximately 2 min. We conclude that we can achieve accurate and precise calibration using a single US image, provided that a large number (approximately ten) of N-fiducials are captured within the US image, enabling a representative sampling of the imaging plane.

  12. Polymers for Traveling Wave Ion Mobility Spectrometry Calibration

    NASA Astrophysics Data System (ADS)

    Duez, Quentin; Chirot, Fabien; Liénard, Romain; Josse, Thomas; Choi, ChangMin; Coulembier, Olivier; Dugourd, Philippe; Cornil, Jérôme; Gerbaux, Pascal; De Winter, Julien

    2017-07-01

    One of the main issues when using traveling wave ion mobility spectrometry (TWIMS) for the determination of collisional cross-section (CCS) concerns the need for a robust calibration procedure built from referent ions of known CCS. Here, we implement synthetic polymer ions as CCS calibrants in positive ion mode. Based on their intrinsic polydispersities, polymers offer in a single sample the opportunity to generate, upon electrospray ionization, numerous ions covering a broad mass range and a large CCS window for different charge states at a time. In addition, the key advantage of polymer ions as CCS calibrants lies in the robustness of their gas-phase structure with respect to the instrumental conditions, making them less prone to collisional-induced unfolding (CIU) than protein ions. In this paper, we present a CCS calibration procedure using sodium cationized polylactide and polyethylene glycol, PLA and PEG, as calibrants with reference CCS determined on a home-made drift tube. Our calibration procedure is further validated by testing the polymer calibration to determine CCS of numerous different ions for which CCS are reported in the literature. [Figure not available: see fulltext.

  13. Direct current electrical potential measurement of the growth of small cracks

    NASA Technical Reports Server (NTRS)

    Gangloff, Richard P.; Slavik, Donald C.; Piascik, Robert S.; Van Stone, Robert H.

    1992-01-01

    The analytical and experimental aspects of the direct-current electrical potential difference (dcEPD) method for continuous monitoring of the growth kinetics of short (50 to 500 microns) fatigue cracks are reviewed, and successful applications of the deEPD method to study fatigue crack propagation in a variety of metallic alloys exposed to various environments are described. Particular attention is given to the principle of the dcEPD method, the analytical electrical potential calibration relationships, and the experimental procedures and equipment.

  14. NASA Glenn Icing Research Tunnel: 2012 Cloud Calibration Procedure and Results

    NASA Technical Reports Server (NTRS)

    VanZante, Judith Foss; Ide, Robert F.; Steen, Laura E.

    2012-01-01

    In 2011, NASA Glenn s Icing Research Tunnel underwent a major modification to it s refrigeration plant and heat exchanger. This paper presents the results of the subsequent full cloud calibration. Details of the calibration procedure and results are presented herein. The steps include developing a nozzle transfer map, establishing a uniform cloud, conducting a drop sizing calibration and finally a liquid water content calibration. The goal of the calibration is to develop a uniform cloud, and to build a transfer map from the inputs of air speed, spray bar atomizing air pressure and water pressure to the output of median volumetric droplet diameter and liquid water content.

  15. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James F.; Cobb, Ernest D.; Kilpatrick, F.A.

    1986-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.

  16. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James F.

    1968-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.

  17. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James E.; Cobb, Ernest D.; Kilpatrick, Frederick A.

    1984-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The outstanding characteristics of dye tracing are: (1) the low detection and measurement limits, and (2) the simplicity and accuracy of measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a general guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section is included on aerial photography because of its possible use to supplement ground-level fluorometry.

  18. Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

    PubMed

    Choleau, C; Klein, J C; Reach, G; Aussedat, B; Demaria-Pesce, V; Wilson, G S; Gifford, R; Ward, W K

    2002-08-01

    Calibration, i.e. the transformation in real time of the signal I(t) generated by the glucose sensor at time t into an estimation of glucose concentration G(t), represents a key issue for the development of a continuous glucose monitoring system. To compare two calibration procedures. In the one-point calibration, which assumes that I(o) is negligible, S is simply determined as the ratio I/G, and G(t) = I(t)/S. The two-point calibration consists in the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The subsequent estimation of G(t) is given by G(t) = (I(t)-I(o))/S. A glucose sensor was implanted in the abdominal subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). The one-point calibration was performed a posteriori either once per day before breakfast, or twice per day before breakfast and dinner, or three times per day before each meal. The two-point calibration was performed each morning during breakfast. The percentages of points present in zones A and B of the Clarke Error Grid were significantly higher when the system was calibrated using the one-point calibration. Use of two one-point calibrations per day before meals was virtually as accurate as three one-point calibrations. This study demonstrates the feasibility of a simple method for calibrating a continuous glucose monitoring system.

  19. Status of calibration and data evaluation of AMSR on board ADEOS-II

    NASA Astrophysics Data System (ADS)

    Imaoka, Keiji; Fujimoto, Yasuhiro; Kachi, Misako; Takeshima, Toshiaki; Igarashi, Tamotsu; Kawanishi, Toneo; Shibata, Akira

    2004-02-01

    The Advanced Microwave Scanning Radiometer (AMSR) is the multi-frequency, passive microwave radiometer on board the Advanced Earth Observing Satellite-II (ADEOS-II), currently called Midori-II. The instrument has eight-frequency channels with dual polarization (except 50-GHz band) covering frequencies between 6.925 and 89.0 GHz. Measurement of 50-GHz channels is the first attempt by this kind of conically scanning microwave radiometers. Basic concept of the instrument including hardware configuration and calibration method is almost the same as that of ASMR for EOS (AMSR-E), the modified version of AMSR. Its swath width of 1,600 km is wider than that of AMSR-E. In parallel with the calibration and data evaluation of AMSR-E instrument, almost identical calibration activities have been made for AMSR instrument. After finished the initial checkout phase, the instrument has been continuously obtaining the data in global basis. Time series of radiometer sensitivities and automatic gain control telemetry indicate the stable instrument performance. For the radiometric calibration, we are now trying to apply the same procedure that is being used for AMSR-E. This paper provides an overview of the instrument characteristics, instrument status, and preliminary results of calibration and data evaluation activities.

  20. Portable light source unit for simulating fires having an adjustable aperture

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C. (Inventor); Moerk, John S. (Inventor); Strobel, James P. (Inventor)

    1997-01-01

    A portable, hand held light source unit is employed to check operation of fire detectors, such as hydrogen fire detectors. The unit emits radiation in a narrow band of wavelengths which are generated by the type of fire to be tested, but not by other light sources such as the sun or incandescent lamps. The unit can test fire detectors at different distances, and of different sensitivities. The intensity of the radiation emitted by the unit is adjustable for this purpose by means of a rotatable disk having a plurality of different sized apertures for selective placement between the light source and an output lens. The disk can also be rotated to a calibration position which causes a microprocessor circuit in the unit to initiate a calibration procedure. During this procedure, the lamp intensity is measured by a photodetector contained within the unit, and the microprocessor adjusts the lamp current to insure that its intensity remains within a preset range of values. A green and a red LED are mounted on the unit which indicate to an operator whether the calibration is successful, as well as the condition of the unit's battery power supply.

  1. Comparison of Signal Response Between EDM Notch and Cracks in Eddy-Current Testing

    NASA Technical Reports Server (NTRS)

    Kane, Mary; Koshti, Ajay

    2008-01-01

    In the field of ET an eddy-current instrument is calibrated on a manufactured notch that is designed to simulate a defect in a part. The calibrated instrument is then used to scan parts with the assumption that any response that is over half the amplitude of the notch signal is taken to be defective. The purpose of this study is to attempt a direct comparison of the signal response observed from an EDM notch to a crack of the same size. To make this comparison test equipment will be set up and calibrated as per normal inspection procedures. Once this has been achieved both notches and as many different sizes of crack specimens will be scanned and the data recorded. This data will then be analyzed to provide a comparison of the response. The results should also provide information that shows it is acceptable to use the half-amplitude method for determining if a part is defective. The tests will be performed on two different materials commonly inspected, titanium and aluminum. This will allow a comparison of the results between materials.

  2. Procedures for establishing and maintaining consistent air-kerma strength standards for low-energy, photon-emitting brachytherapy sources: recommendations of the Calibration Laboratory Accreditation Subcommittee of the American Association of Physicists in Medicine.

    PubMed

    DeWerd, Larry A; Huq, M Saiful; Das, Indra J; Ibbott, Geoffrey S; Hanson, William F; Slowey, Thomas W; Williamson, Jeffrey F; Coursey, Bert M

    2004-03-01

    Low dose rate brachytherapy is being used extensively for the treatment of prostate cancer. As of September 2003, there are a total of thirteen 125I and seven 103Pd sources that have calibrations from the National Institute of Standards and Technology (NIST) and the Accredited Dosimetry Calibration Laboratories (ADCLs) of the American Association of Physicists in Medicine (AAPM). The dosimetry standards for these sources are traceable to the NIST wide-angle free-air chamber. Procedures have been developed by the AAPM Calibration Laboratory Accreditation Subcommittee to standardize quality assurance and calibration, and to maintain the dosimetric traceability of these sources to ensure accurate clinical dosimetry. A description of these procedures is provided to the clinical users for traceability purposes as well as to provide guidance to the manufacturers of brachytherapy sources and ADCLs with regard to these procedures.

  3. 40 CFR 91.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... required (see following table). Example calibration points (percent) Acceptable for calibration? 20, 30, 40... periodic interference, system check, and calibration test procedures specified in 40 CFR part 1065...

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CALIBRATION OF HARVARD PM SAMPLERS (UA-L-6.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for calibrating Harvard particulate matter (PM) samplers. This procedure applies directly to the Harvard particulate matter (PM) samplers used during the Arizona NHEXAS project and the "Border" study. Keywords: lab; equipmen...

  5. Calibration of low-temperature ac susceptometers with a copper cylinder standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, D.-X.; Skumryev, V.

    2010-02-15

    A high-quality low-temperature ac susceptometer is calibrated by comparing the measured ac susceptibility of a copper cylinder with its eddy-current ac susceptibility accurately calculated. Different from conventional calibration techniques that compare the measured results with the known property of a standard sample at certain fixed temperature T, field amplitude H{sub m}, and frequency f, to get a magnitude correction factor, here, the electromagnetic properties of the copper cylinder are unknown and are determined during the calibration of the ac susceptometer in the entire T, H{sub m}, and f range. It is shown that the maximum magnitude error and the maximummore » phase error of the susceptometer are less than 0.7% and 0.3 deg., respectively, in the region T=5-300 K and f=111-1111 Hz at H{sub m}=800 A/m, after a magnitude correction by a constant factor as done in a conventional calibration. However, the magnitude and phase errors can reach 2% and 4.3 deg. at 10 000 and 11 Hz, respectively. Since the errors are reproducible, a large portion of them may be further corrected after a calibration, the procedure for which is given. Conceptual discussions concerning the error sources, comparison with other calibration methods, and applications of ac susceptibility techniques are presented.« less

  6. Workcell calibration for effective offline programming

    NASA Technical Reports Server (NTRS)

    Stiles, Roger D.; Jones, Clyde S.

    1989-01-01

    In the application of graphics systems for off-line programming (OLP) of robotic systems, the inevitability of errors in the model representation of real-world situations requires that a method to map these differences is incorporated as an integral part of the overall system progamming procedures. This paper discusses several proven robot-to-positioner calibration techniques necessary to reflect real-world parameters in a work-cell model. Particular attention is given to the procedures used to adjust a graphics model to an acceptable degree of accuracy for integration of OLP for the Space Shuttle Main Engine welding automation. Consideration is given to the levels of calibration, requirements, special considerations for coordinated motion, and calibration procedures.

  7. Evaluation of variability and quality control procedures for a receptor-binding assay for paralytic shellfish poisoning toxins.

    PubMed

    Ruberu, S R; Langlois, G W; Masuda, M; Perera, S Kusum

    2012-01-01

    The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to method variability. The overall inherent RBA variability was determined to be 17%. Variability within the 12 detectors was observed; however, there was no reproducible pattern in detector performance. This observed variability among detectors could be attributed to other factors, such as pipetting errors. In an attempt to reduce the number of plates rejected due to excessive variability in the method's quality control parameters, a statistical approach was evaluated using either Grubbs' test or the Student's t-test for rejecting outliers in the measurement of triplicate wells. This approach improved the ratio of accepted versus rejected plates, saving cost and time for rerunning the assay. However, the potential reduction in accuracy and the lack of improvement in precision suggests caution when using this approach. The current study has recommended an alternate quality control procedure for accepting or rejecting plates in place of the criteria currently used in the published assay, or the alternative of outlier testing. The recommended procedure involves the development of control charts to monitor the critical parameters identified in the published method (QC sample, EC₅₀, slope of calibration curve), with the addition of a fourth critical parameter which is the top value (100% binding) of the calibration curve.

  8. Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ferris, A. T. Judy

    1999-01-01

    This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

  9. Sensitivity and Calibration of Non-Destructive Evaluation Method That Uses Neural-Net Processing of Characteristic Fringe Patterns

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.; Weiland, Kenneth E.

    2003-01-01

    This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

  10. Chasing the TIRS ghosts: calibrating the Landsat 8 thermal bands

    NASA Astrophysics Data System (ADS)

    Schott, John R.; Gerace, Aaron; Raqueno, Nina; Ientilucci, Emmett; Raqueno, Rolando; Lunsford, Allen W.

    2014-10-01

    The Thermal Infrared Sensor (TIRS) on board Landsat 8 has exhibited a number of anomalous characteristics that have made it difficult to calibrate. These anomalies include differences in the radiometric appearance across the blackbody pre- and post-launch, variations in the cross calibration ratios between detectors that overlap on adjacent arrays (resulting in banding) and bias errors in the absolute calibration that can change spatially/temporally. Several updates to the TIRS calibration procedures were made in the months after launch to attempt to mitigate the impact of these anomalies on flat fielding (cosmetic removal of banding and striping) and mean level bias correction. As a result, banding and striping variations have been reduced but not eliminated and residual bias errors in band 10 should be less than 2 degrees for most targets but can be significantly more in some cases and are often larger in band 11. These corrections have all been essentially ad hoc without understanding or properly accounting for the source of the anomalies, which were, at the time unknown. This paper addresses the procedures that have been undertaken to; better characterize the nature of these anomalies, attempt to identify the source(s) of the anomalies, quantify the phenomenon responsible for them, and develop correction procedures to more effectively remove the impacts on the radiometric products. Our current understanding points to all of the anomalies being the result of internal reflections of energy from outside the target detector's field-of-view, and often outside the telescope field-of-view, onto the target detector. This paper discusses how various members of the Landsat calibration team discovered the clues that led to how; these "ghosts" were identified, they are now being characterized, and their impact can hopefully eventually be corrected. This includes use of lunar scans to generate initial maps of influence regions, use of long path overlap ratios to explore sources of change and use of variations in bias calculated from truth sites to quantify influences from the surround on absolute bias errors.

  11. Non-uniformity calibration for MWIR polarization imagery obtained with integrated microgrid polarimeters

    NASA Astrophysics Data System (ADS)

    Liu, Hai-Zheng; Shi, Ze-Lin; Feng, Bin; Hui, Bin; Zhao, Yao-Hong

    2016-03-01

    Integrating microgrid polarimeters on focal plane array (FPA) of an infrared detector causes non-uniformity of polarization response. In order to reduce the effect of polarization non-uniformity, this paper constructs an experimental setup for capturing raw flat-field images and proposes a procedure for acquiring non-uniform calibration (NUC) matrix and calibrating raw polarization images. The proposed procedure takes the incident radiation as a polarization vector and offers a calibration matrix for each pixel. Both our matrix calibration and two-point calibration are applied to our mid-wavelength infrared (MWIR) polarization imaging system with integrated microgrid polarimeters. Compared with two point calibration, our matrix calibration reduces non-uniformity by 30 40% under condition of flat-field data test with polarization. The ourdoor scene observation experiment indicates that our calibration can effectively reduce polarization non-uniformity and improve the image quality of our MWIR polarization imaging system.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR CALIBRATION OF HARVARD PM SAMPLERS (UA-L-6.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for calibrating Harvard particulate matter (PM) samplers. This procedure applies directly to the Harvard particulate matter (PM) samplers used during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment;...

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CALIBRATION, MAINTENANCE AND OPERATION OF ELECTRONIC BALANCES (BCO-L-23.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures to be followed for the operation, calibration and maintenance of electronic balances. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: ...

  14. Calibration and correction procedures for cosmic-ray neutron soil moisture probes located across Australia

    NASA Astrophysics Data System (ADS)

    Hawdon, Aaron; McJannet, David; Wallace, Jim

    2014-06-01

    The cosmic-ray probe (CRP) provides continuous estimates of soil moisture over an area of ˜30 ha by counting fast neutrons produced from cosmic rays which are predominantly moderated by water molecules in the soil. This paper describes the setup, measurement correction procedures, and field calibration of CRPs at nine locations across Australia with contrasting soil type, climate, and land cover. These probes form the inaugural Australian CRP network, which is known as CosmOz. CRP measurements require neutron count rates to be corrected for effects of atmospheric pressure, water vapor pressure changes, and variations in incoming neutron intensity. We assess the magnitude and importance of these corrections and present standardized approaches for network-wide analysis. In particular, we present a new approach to correct for incoming neutron intensity variations and test its performance against existing procedures used in other studies. Our field calibration results indicate that a generalized calibration function for relating neutron counts to soil moisture is suitable for all soil types, with the possible exception of very sandy soils with low water content. Using multiple calibration data sets, we demonstrate that the generalized calibration function only applies after accounting for persistent sources of hydrogen in the soil profile. Finally, we demonstrate that by following standardized correction procedures and scaling neutron counting rates of all CRPs to a single reference location, differences in calibrations between sites are related to site biomass. This observation provides a means for estimating biomass at a given location or for deriving coefficients for the calibration function in the absence of field calibration data.

  15. Geometrical Characterisation of a 2D Laser System and Calibration of a Cross-Grid Encoder by Means of a Self-Calibration Methodology

    PubMed Central

    Torralba, Marta; Díaz-Pérez, Lucía C.

    2017-01-01

    This article presents a self-calibration procedure and the experimental results for the geometrical characterisation of a 2D laser system operating along a large working range (50 mm × 50 mm) with submicrometre uncertainty. Its purpose is to correct the geometric errors of the 2D laser system setup generated when positioning the two laser heads and the plane mirrors used as reflectors. The non-calibrated artefact used in this procedure is a commercial grid encoder that is also a measuring instrument. Therefore, the self-calibration procedure also allows the determination of the geometrical errors of the grid encoder, including its squareness error. The precision of the proposed algorithm is tested using virtual data. Actual measurements are subsequently registered, and the algorithm is applied. Once the laser system is characterised, the error of the grid encoder is calculated along the working range, resulting in an expanded submicrometre calibration uncertainty (k = 2) for the X and Y axes. The results of the grid encoder calibration are comparable to the errors provided by the calibration certificate for its main central axes. It is, therefore, possible to confirm the suitability of the self-calibration methodology proposed in this article. PMID:28858239

  16. Fermentation process tracking through enhanced spectral calibration modeling.

    PubMed

    Triadaphillou, Sophia; Martin, Elaine; Montague, Gary; Norden, Alison; Jeffkins, Paul; Stimpson, Sarah

    2007-06-15

    The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

  17. Toward a standard line for use in multibeam echo sounder calibration

    NASA Astrophysics Data System (ADS)

    Weber, Thomas C.; Rice, Glen; Smith, Michael

    2018-06-01

    A procedure is suggested in which a relative calibration for the intensity output of a multibeam echo sounder (MBES) can be performed. This procedure identifies a common survey line (i.e., a standard line), over which acoustic backscatter from the seafloor is collected with multiple MBES systems or by the same system multiple times. A location on the standard line which exhibits temporal stability in its seafloor backscatter response is used to bring the intensity output of the multiple MBES systems to a common reference. This relative calibration procedure has utility for MBES users wishing to generate an aggregate seafloor backscatter mosaic using multiple systems, revisiting an area to detect changes in substrate type, and comparing substrate types in the same general area but with different systems or different system settings. The calibration procedure is demonstrated using three different MBES systems over 3 different years in New Castle, NH, USA.

  18. LANDSAT-4 multispectral scanner (MSS) subsystem radiometric characterization

    NASA Technical Reports Server (NTRS)

    Alford, W. (Editor); Barker, J. (Editor); Clark, B. P.; Dasgupta, R.

    1983-01-01

    The multispectral band scanner (mass) and its spectral characteristics are described and methods are given for relating video digital levels on computer compatible tapes to radiance into the sensor. Topics covered include prelaunch calibration procedures and postlaunch radiometric processng. Examples of current data resident on the MSS image processing system are included. The MSS on LANDSAT 4 is compared with the scanners on earlier LANDSAT satellites.

  19. A multi-objective approach to improve SWAT model calibration in alpine catchments

    NASA Astrophysics Data System (ADS)

    Tuo, Ye; Marcolini, Giorgia; Disse, Markus; Chiogna, Gabriele

    2018-04-01

    Multi-objective hydrological model calibration can represent a valuable solution to reduce model equifinality and parameter uncertainty. The Soil and Water Assessment Tool (SWAT) model is widely applied to investigate water quality and water management issues in alpine catchments. However, the model calibration is generally based on discharge records only, and most of the previous studies have defined a unique set of snow parameters for an entire basin. Only a few studies have considered snow observations to validate model results or have taken into account the possible variability of snow parameters for different subbasins. This work presents and compares three possible calibration approaches. The first two procedures are single-objective calibration procedures, for which all parameters of the SWAT model were calibrated according to river discharge alone. Procedures I and II differ from each other by the assumption used to define snow parameters: The first approach assigned a unique set of snow parameters to the entire basin, whereas the second approach assigned different subbasin-specific sets of snow parameters to each subbasin. The third procedure is a multi-objective calibration, in which we considered snow water equivalent (SWE) information at two different spatial scales (i.e. subbasin and elevation band), in addition to discharge measurements. We tested these approaches in the Upper Adige river basin where a dense network of snow depth measurement stations is available. Only the set of parameters obtained with this multi-objective procedure provided an acceptable prediction of both river discharge and SWE. These findings offer the large community of SWAT users a strategy to improve SWAT modeling in alpine catchments.

  20. The Calibration of dc Voltage Standards at NIST

    PubMed Central

    Field, Bruce F.

    1990-01-01

    This document describes the procedures used at NIST to calibrate dc voltage standards in terms of the NIST volt. Three calibration services are offered by the Electricity Division: Regular Calibration Service (RCS) of client standard cells at NIST; the Volt Transfer Program (VTP) a process to determine the difference between the NIST volt and the volt as maintained by a group of standard cells in a client laboratory; and the calibration of client solid-state dc voltage standards at NIST. The operational procedures used to compare these voltage standards to NIST voltage standards and to maintain the NIST volt via the ac Josephson effect are discussed. PMID:28179777

  1. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF FIXED AND ADJUSTABLE VOLUME PIPETTE GUNS (BCO-L-9.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures for the operation, calibration, and maintenance of fixed- and adjustable-volume pipette guns. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Ke...

  2. Mathematical calibration procedure of a capacitive sensor-based indexed metrology platform

    NASA Astrophysics Data System (ADS)

    Brau-Avila, A.; Santolaria, J.; Acero, R.; Valenzuela-Galvan, M.; Herrera-Jimenez, V. M.; Aguilar, J. J.

    2017-03-01

    The demand for faster and more reliable measuring tasks for the control and quality assurance of modern production systems has created new challenges for the field of coordinate metrology. Thus, the search for new solutions in coordinate metrology systems and the need for the development of existing ones still persists. One example of such a system is the portable coordinate measuring machine (PCMM), the use of which in industry has considerably increased in recent years, mostly due to its flexibility for accomplishing in-line measuring tasks as well as its reduced cost and operational advantages compared to traditional coordinate measuring machines. Nevertheless, PCMMs have a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification and optimization procedures. In this work the mathematical calibration procedure of a capacitive sensor-based indexed metrology platform (IMP) is presented. This calibration procedure is based on the readings and geometric features of six capacitive sensors and their targets with nanometer resolution. The final goal of the IMP calibration procedure is to optimize the geometric features of the capacitive sensors and their targets in order to use the optimized data in the verification procedures of PCMMs.

  3. Energy Reconstruction for Events Detected in TES X-ray Detectors

    NASA Astrophysics Data System (ADS)

    Ceballos, M. T.; Cardiel, N.; Cobo, B.

    2015-09-01

    The processing of the X-ray events detected by a TES (Transition Edge Sensor) device (such as the one that will be proposed in the ESA AO call for instruments for the Athena mission (Nandra et al. 2013) as a high spectral resolution instrument, X-IFU (Barret et al. 2013)), is a several step procedure that starts with the detection of the current pulses in a noisy signal and ends up with their energy reconstruction. For this last stage, an energy calibration process is required to convert the pseudo energies measured in the detector to the real energies of the incoming photons, accounting for possible nonlinearity effects in the detector. We present the details of the energy calibration algorithm we implemented as the last part of the Event Processing software that we are developing for the X-IFU instrument, that permits the calculation of the calibration constants in an analytical way.

  4. Experimental light scattering by small particles: system design and calibration

    NASA Astrophysics Data System (ADS)

    Maconi, Göran; Kassamakov, Ivan; Penttilä, Antti; Gritsevich, Maria; Hæggström, Edward; Muinonen, Karri

    2017-06-01

    We describe a setup for precise multi-angular measurements of light scattered by mm- to μm-sized samples. We present a calibration procedure that ensures accurate measurements. Calibration is done using a spherical sample (d = 5 mm, n = 1.517) fixed on a static holder. The ultimate goal of the project is to allow accurate multi-wavelength measurements (the full Mueller matrix) of single-particle samples which are levitated ultrasonically. The system comprises a tunable multimode Argon-krypton laser, with 12 wavelengths ranging from 465 to 676 nm, a linear polarizer, a reference photomultiplier tube (PMT) monitoring beam intensity, and several PMT:s mounted radially towards the sample at an adjustable radius. The current 150 mm radius allows measuring all azimuthal angles except for ±4° around the backward scattering direction. The measurement angle is controlled by a motor-driven rotational stage with an accuracy of 15'.

  5. A self-calibrating multicomponent force/torque measuring system

    NASA Astrophysics Data System (ADS)

    Marangoni, Rafael R.; Schleichert, Jan; Rahneberg, Ilko; Hilbrunner, Falko; Fröhlich, Thomas

    2018-07-01

    A multicomponent self-calibrating force and torque sensor is presented. In this system, the principle of a Kibble balance is adapted for the traceable force and torque measurement in three orthogonal directions. The system has two operating modes: the velocity mode and the force/torque sensing mode. In the velocity mode, the calibration of the sensor is performed, while in the force/torque sensing mode, forces and torques are measured by using the principle of the electromagnetic force compensation. Details about the system are provided, with the main components of the sensor and a description of the operational procedure. A prototype of the system is currently being implemented for measuring forces and torques in a range of  ±2 N and  ±0.1 N · m respectively. A maximal relative expanded measurement uncertainty (k  =  2) of 1 · 10‑4 is expected for the force and torque measurements.

  6. Hydrodynamic Energy Saving Enhancements for DDG 51 Class Ships

    DTIC Science & Technology

    2012-02-01

    temperature and pressure in the hydraulic pitch control system, expansion and contraction of the pitch control rods, improper pitch calibration procedure ...outdated pitch calibration, etc. Experience during hot pitch calibration procedures conducted by NSWCCD prior to powering trials has indicated that...18% increase in power.10 Sea trials conducted during a long-term evaluation on the USS WHIPPLE (FF 1062), showed that by 800 days out of drydock

  7. SWAT: Model use, calibration, and validation

    USDA-ARS?s Scientific Manuscript database

    SWAT (Soil and Water Assessment Tool) is a comprehensive, semi-distributed river basin model that requires a large number of input parameters which complicates model parameterization and calibration. Several calibration techniques have been developed for SWAT including manual calibration procedures...

  8. 40 CFR 1065.325 - Intake-flow calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 1065.325 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Flow-Related Measurements § 1065.325 Intake-flow calibration. (a) Calibrate intake-air flow meters upon initial installation. Follow the...

  9. Simulation model calibration and validation : phase II : development of implementation handbook and short course.

    DOT National Transportation Integrated Search

    2006-01-01

    A previous study developed a procedure for microscopic simulation model calibration and validation and evaluated the procedure via two relatively simple case studies using three microscopic simulation models. Results showed that default parameters we...

  10. 40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...

  11. 40 CFR 1066.215 - Summary of verification and calibration procedures for chassis dynamometers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer... manufacturer instructions and good engineering judgment. (c) Automated dynamometer verifications and... accomplish the verifications and calibrations specified in this subpart. You may use these automated...

  12. First full dynamic range calibration of the JUNGFRAU photon detector

    NASA Astrophysics Data System (ADS)

    Redford, S.; Andrä, M.; Barten, R.; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Fröjdh, E.; Greiffenberg, D.; Lopez-Cuenca, C.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Ruat, M.; Ruder, C.; Schmitt, B.; Shi, X.; Thattil, D.; Tinti, G.; Vetter, S.; Zhang, J.

    2018-01-01

    The JUNGFRAU detector is a charge integrating hybrid silicon pixel detector developed at the Paul Scherrer Institut for photon science applications, in particular for the upcoming free electron laser SwissFEL. With a high dynamic range, analogue readout, low noise and three automatically switching gains, JUNGFRAU promises excellent performance not only at XFELs but also at synchrotrons in areas such as protein crystallography, ptychography, pump-probe and time resolved measurements. To achieve its full potential, the detector must be calibrated on a pixel-by-pixel basis. This contribution presents the current status of the JUNGFRAU calibration project, in which a variety of input charge sources are used to parametrise the energy response of the detector across four orders of magnitude of dynamic range. Building on preliminary studies, the first full calibration procedure of a JUNGFRAU 0.5 Mpixel module is described. The calibration is validated using alternative sources of charge deposition, including laboratory experiments and measurements at ESRF and LCLS. The findings from these measurements are presented. Calibrated modules have already been used in proof-of-principle style protein crystallography experiments at the SLS. A first look at selected results is shown. Aspects such as the conversion of charge to number of photons, treatment of multi-size pixels and the origin of non-linear response are also discussed.

  13. ACCOUNTING FOR CALIBRATION UNCERTAINTIES IN X-RAY ANALYSIS: EFFECTIVE AREAS IN SPECTRAL FITTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hyunsook; Kashyap, Vinay L.; Drake, Jeremy J.

    2011-04-20

    While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here, we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can bemore » applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.« less

  14. ERS-1 scatterometer calibration and validation activities at ECMWF. B: From radar backscatter characteristics to wind vector solutions

    NASA Technical Reports Server (NTRS)

    Stoffelen, AD; Anderson, David L. T.; Woiceshyn, Peter M.

    1992-01-01

    Calibration and validation activities for the ERS-1 scatterometer were carried out at ECMWF (European Center for Medium range Weather Forecast) complementary to the 'Haltenbanken' field campaign off the coast of Norway. At a Numerical Weather Prediction (NWP) center a wealth of verifying data is available both in time and space. This data is used to redefine the wind retrieval procedure given the instrumental characteristics. It was found that a maximum likelihood estimation procedure to obtain the coefficients of a reformulated sigma deg to wind relationship should use radar measurements in logarithmic rather than physical space, and use winds as the wind components rather than wind speed and direction. Doing this, a much more accurate transfer function than the one currently operated by ESA was derived. Sigma deg measurement space shows no signature of a separation in an upwind solution cone and a downwind solution cone. As such signature was anticipated in ESA's wind direction ambiguity removal algorithm, reconsideration of the procedure is necessary. Despite the fact that revisions have to be made in the process of wind retrieval; a grid potential is shown for scatterometry in meteorology and climatology.

  15. 40 CFR 90.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (64 percent) is required (see following table). Example calibration points (%) Acceptable for... periodic interference, system check, and calibration test procedures specified in 40 CFR part 1065...

  16. 40 CFR 90.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (64 percent) is required (see following table). Example calibration points (%) Acceptable for... periodic interference, system check, and calibration test procedures specified in 40 CFR part 1065...

  17. 40 CFR 90.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (64 percent) is required (see following table). Example calibration points (%) Acceptable for... periodic interference, system check, and calibration test procedures specified in 40 CFR part 1065...

  18. SU-E-T-749: Thorough Calibration of MOSFET Dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plenkovich, D; Thomas, J

    Purpose: To improve the accuracy of the MOSFET calibration procedure by performing the measurement several times and calculating the average value of the calibration factor for various photon and electron energies. Methods: The output of three photon and six electron beams of Varian Trilogy linear accelerator SN 5878 was calibrated. Five reinforced standard sensitivity MOSFET dosimeters were placed in the calibration jig and connected to the Reader Module. As the backscatter material was used 7 cm of Virtual Water. The MOSFET dosimeters were covered with 1.5 cm thick bolus for the regular and SRS 6 MV beams, 3 cm bolusmore » for 15 MV beam, 1.5 cm bolus for 6 MeV electron beam, and 2 cm bolus for the electron energies of 9, 12, 15, 18, and 22 MeV. The dosimeters were exposed to 100 MU, and the calibration factor was determined using the mobileMOSFET software. To improve the accuracy of calibration, this procedure was repeated ten times and the calibration factors were averaged. Results: As the number of calibrations was increasing the variability of calibration factors of different dosimeters was decreasing. After ten calibrations, the calibration factors for all five dosimeters were within 1% of one another for all energies, except 6 MV SRS photons and 6 MeV electrons, for which the variability was 2%. Conclusions: The described process results in calibration factors which are almost independent of modality or energy. Once calibrated, the dosimeters may be used for in-vivo dosimetry or for daily verification of the beam output. Measurement of the radiation dose under bolus and scatter to the eye are examples of frequent use of calibrated MOSFET dosimeters. The calibration factor determined for full build-up is used under these circumstances. To the best of our knowledge, such thorough procedure for calibrating MOSFET dosimeters has not been reported previously. Best Medical Canada provided MOSFET dosimeters for this project.« less

  19. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in section 2.3 of this appendix and the Hg emission tests described in §§ 75.81(c) and 75.81(d)(4). 1.2Specific Requirements for Continuous Emissions Monitoring Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and...

  20. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF FIXED AND ADJUSTABLE VOLUME PIPETTE GUNS (BCO-L-9.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures for the operation, calibration, and maintenance of fixed- and adjustable-volume pipette guns. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keyw...

  1. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND ROUTINE USE OF THE SPECTRACE 9000 FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER (UA-L-10.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for operating and calibrating the Spectrace 9000 field portable X-ray fluorescence analyzer. This procedure applies to the determination of metal concentrations in samples during the Arizona NHEXAS project and the "Border" st...

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF THE PERKIN-ELMER 1100B ATOMIC ABSORPTION SPECTROMETER (BCO-L-5.1)

    EPA Science Inventory

    The purpose of this SOP is to outline the start-up, calibration, operation, and maintenance procedures for the Perkin-Elmer 5100 PC Atomic Absorption Spectrophotometer (PE 5100). These procedures are used for the determination of the target trace metal, as in soil, house dust, f...

  3. 40 CFR 91.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (64 percent) is required (see following table). Example calibration points (percent) Acceptable for...) The initial and periodic interference, system check, and calibration test procedures specified in 40...

  4. 40 CFR 91.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (64 percent) is required (see following table). Example calibration points (percent) Acceptable for...) The initial and periodic interference, system check, and calibration test procedures specified in 40...

  5. 40 CFR 91.320 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (64 percent) is required (see following table). Example calibration points (percent) Acceptable for...) The initial and periodic interference, system check, and calibration test procedures specified in 40...

  6. Calibrating SANS data for instrument geometry and pixel sensitivity effects: access to an extended Q range

    PubMed Central

    Karge, Lukas; Gilles, Ralph

    2017-01-01

    An improved data-reduction procedure is proposed and demonstrated for small-angle neutron scattering (SANS) measurements. Its main feature is the correction of geometry- and wavelength-dependent intensity variations on the detector in a separate step from the different pixel sensitivities: the geometric and wavelength effects can be corrected analytically, while pixel sensitivities have to be calibrated to a reference measurement. The geometric effects are treated for position-sensitive 3He proportional counter tubes, where they are anisotropic owing to the cylindrical geometry of the gas tubes. For the calibration of pixel sensitivities, a procedure is developed that is valid for isotropic and anisotropic signals. The proposed procedure can save a significant amount of beamtime which has hitherto been used for calibration measurements. PMID:29021734

  7. Neural-Net Based Optical NDE Method for Structural Health Monitoring

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.; Weiland, Kenneth E.

    2003-01-01

    This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

  8. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

    NASA Astrophysics Data System (ADS)

    Astrua, M.; Iacomini, L.; Battuello, M.

    2008-10-01

    The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

  9. 40 CFR 204.54 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... frequency response calibration and an attenuator (gain control) calibration plus a measurement of dynamic... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Test procedures. 204.54 Section 204.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS NOISE EMISSION...

  10. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  11. 40 CFR 91.425 - CVS calibration frequency.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...

  12. 40 CFR 91.425 - CVS calibration frequency.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...

  13. 40 CFR 91.425 - CVS calibration frequency.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...

  14. 40 CFR 91.425 - CVS calibration frequency.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...

  15. 40 CFR 91.425 - CVS calibration frequency.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...

  16. Materials Evaluation in the Tri-Service Thermal Radiation Test Facility.

    DTIC Science & Technology

    1981-02-28

    degradation of materials exposed to the radiant heating generated by a nuclear blast can vary enor- mously. The intense radiation needed to simulate a...of surface degradation was accomplished with limited success during the current contract effort. Procedures still need refining to make surface...147; 148; 149 (Table I) 6648-6666 FACILITY CALIBRATION 6667 Aluminized Tape No coating 6668-6742 Aluminum NBR /EDPM blends, Vamac 6743-6755 Wind tunnel

  17. 40 CFR 1065.640 - Flow meter calibration calculations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Flow meter calibration calculations... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.640 Flow meter calibration calculations. This section describes the calculations for calibrating various flow meters. After...

  18. Finding trap stiffness of optical tweezers using digital filters.

    PubMed

    Almendarez-Rangel, Pedro; Morales-Cruzado, Beatriz; Sarmiento-Gómez, Erick; Pérez-Gutiérrez, Francisco G

    2018-02-01

    Obtaining trap stiffness and calibration of the position detection system is the basis of a force measurement using optical tweezers. Both calibration quantities can be calculated using several experimental methods available in the literature. In most cases, stiffness determination and detection system calibration are performed separately, often requiring procedures in very different conditions, and thus confidence of calibration methods is not assured due to possible changes in the environment. In this work, a new method to simultaneously obtain both the detection system calibration and trap stiffness is presented. The method is based on the calculation of the power spectral density of positions through digital filters to obtain the harmonic contributions of the position signal. This method has the advantage of calculating both trap stiffness and photodetector calibration factor from the same dataset in situ. It also provides a direct method to avoid unwanted frequencies that could greatly affect calibration procedure, such as electric noise, for example.

  19. a Contemporary Approach for Evaluation of the best Measurement Capability of a Force Calibration Machine

    NASA Astrophysics Data System (ADS)

    Kumar, Harish

    The present paper discusses the procedure for evaluation of best measurement capability of a force calibration machine. The best measurement capability of force calibration machine is evaluated by a comparison through the precision force transfer standards to the force standard machines. The force transfer standards are calibrated by the force standard machine and then by the force calibration machine by adopting the similar procedure. The results are reported and discussed in the paper and suitable discussion has been made for force calibration machine of 200 kN capacity. Different force transfer standards of nominal capacity 20 kN, 50 kN and 200 kN are used. It is found that there are significant variations in the .uncertainty of force realization by the force calibration machine according to the proposed method in comparison to the earlier method adopted.

  20. Radiometer calibration methods and resulting irradiance differences: Radiometer calibration methods and resulting irradiance differences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin

    Accurate solar radiation measured by radiometers depends on instrument performance specifications, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methodologies and resulting differences provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these methods calibrate radiometers indoors and some outdoors. To establish or understand the differences in calibration methodologies, we processed and analyzed field-measured data from radiometers deployed for 10 months at NREL's Solar Radiation Research Laboratory. These different methods of calibration resulted in a difference ofmore » +/-1% to +/-2% in solar irradiance measurements. Analyzing these differences will ultimately assist in determining the uncertainties of the field radiometer data and will help develop a consensus on a standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainties will help the accurate prediction of the output of planned solar conversion projects and improve the bankability of financing solar projects.« less

  1. Effects of line fiducial parameters and beamforming on ultrasound calibration

    PubMed Central

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Peters, Terry M.; Chen, Elvis C. S.

    2017-01-01

    Abstract. Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures. PMID:28331886

  2. Effects of line fiducial parameters and beamforming on ultrasound calibration.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; McLeod, A Jonathan; Peters, Terry M; Chen, Elvis C S

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures.

  3. Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Tcheng, Ping

    1999-01-01

    Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

  4. Raman water vapor lidar calibration

    NASA Astrophysics Data System (ADS)

    Landulfo, E.; Da Costa, R. F.; Torres, A. S.; Lopes, F. J. S.; Whiteman, D. N.; Venable, D. D.

    2009-09-01

    We show here new results of a Raman LIDAR calibration methodology effort putting emphasis in the assessment of the cross-section ratio between water vapor and nitrogen by the use of a calibrated NIST traceable tungsten lamp. Therein we give a step by step procedure of how to employ such equipment by means of a mapping/scanning procedure over the receiving optics of a water vapor Raman LIDAR. This methodology has been independently used at Howard University Raman LIDAR and at IPEN Raman LIDAR what strongly supports its reproducibility and points towards an independently calibration methodology to be carried on within an experiment routine.

  5. A formulation of tissue- and water-equivalent materials using the stoichiometric analysis method for CT-number calibration in radiotherapy treatment planning.

    PubMed

    Yohannes, Indra; Kolditz, Daniel; Langner, Oliver; Kalender, Willi A

    2012-03-07

    Tissue- and water-equivalent materials (TEMs) are widely used in quality assurance and calibration procedures, both in radiodiagnostics and radiotherapy. In radiotherapy, particularly, the TEMs are often used for computed tomography (CT) number calibration in treatment planning systems. However, currently available TEMs may not be very accurate in the determination of the calibration curves due to their limitation in mimicking radiation characteristics of the corresponding real tissues in both low- and high-energy ranges. Therefore, we are proposing a new formulation of TEMs using a stoichiometric analysis method to obtain TEMs for the calibration purposes. We combined the stoichiometric calibration and the basic data method to compose base materials to develop TEMs matching standard real tissues from ICRU Report 44 and 46. First, the CT numbers of six materials with known elemental compositions were measured to get constants for the stoichiometric calibration. The results of the stoichiometric calibration were used together with the basic data method to formulate new TEMs. These new TEMs were scanned to validate their CT numbers. The electron density and the stopping power calibration curves were also generated. The absolute differences of the measured CT numbers of the new TEMs were less than 4 HU for the soft tissues and less than 22 HU for the bone compared to the ICRU real tissues. Furthermore, the calculated relative electron density and electron and proton stopping powers of the new TEMs differed by less than 2% from the corresponding ICRU real tissues. The new TEMs which were formulated using the proposed technique increase the simplicity of the calibration process and preserve the accuracy of the stoichiometric calibration simultaneously.

  6. Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images.

    PubMed

    van der Laak, Jeroen A W M; Dijkman, Henry B P M; Pahlplatz, Martin M M

    2006-03-01

    The magnification factor in transmission electron microscopy is not very precise, hampering for instance quantitative analysis of specimens. Calibration of the magnification is usually performed interactively using replica specimens, containing line or grating patterns with known spacing. In the present study, a procedure is described for automated magnification calibration using digital images of a line replica. This procedure is based on analysis of the power spectrum of Fourier transformed replica images, and is compared to interactive measurement in the same images. Images were used with magnification ranging from 1,000 x to 200,000 x. The automated procedure deviated on average 0.10% from interactive measurements. Especially for catalase replicas, the coefficient of variation of automated measurement was considerably smaller (average 0.28%) compared to that of interactive measurement (average 3.5%). In conclusion, calibration of the magnification in digital images from transmission electron microscopy may be performed automatically, using the procedure presented here, with high precision and accuracy.

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION, AND ROUTINE USE OF THE SPECTRACE 9000 FIELD PORTABLE X-RAY FLUORESCENCE ANALYZER (UA-L-10.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for operating and calibrating the Spectrace 9000 field portable X-ray fluorescence analyzer. This procedure applies to the determination of metal concentrations in samples during the Arizona NHEXAS project and the Border stud...

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION, AND MAINTENANCE OF THE PERKIN-ELMER 5100 PC ATOMIC ABSORPTION SPECTROMETER (BCO-L-5.1)

    EPA Science Inventory

    The purpose of this SOP is to outline the start-up, calibration, operation, and maintenance procedures for the Perkin-Elmer 5100 PC Atomic Absorption Spectrophotometer (PE 5100). These procedures are used for the determination of the target trace metal, as in soil, house dust, f...

  9. 40 CFR 90.425 - CVS calibration frequency.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...

  10. 40 CFR 90.425 - CVS calibration frequency.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...

  11. 40 CFR 90.425 - CVS calibration frequency.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...

  12. 40 CFR 90.425 - CVS calibration frequency.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...

  13. 40 CFR 90.425 - CVS calibration frequency.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...

  14. 40 CFR 86.1524 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Carbon dioxide analyzer calibration. 86.1524 Section 86.1524 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Test Procedures § 86.1524 Carbon dioxide analyzer calibration. (a) The calibration requirements for the...

  15. 40 CFR 86.1524 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Carbon dioxide analyzer calibration. 86.1524 Section 86.1524 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Procedures § 86.1524 Carbon dioxide analyzer calibration. (a) The calibration requirements for the dilute...

  16. 40 CFR 86.1325-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Methane analyzer calibration. 86.1325... Procedures § 86.1325-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the manufacturer's instructions for...

  17. 40 CFR 86.1325-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Methane analyzer calibration. 86.1325... Procedures § 86.1325-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the manufacturer's instructions for...

  18. 40 CFR 86.1325-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Methane analyzer calibration. 86.1325... Procedures § 86.1325-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the manufacturer's instructions for...

  19. 40 CFR 86.1325-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Methane analyzer calibration. 86.1325... Procedures § 86.1325-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the manufacturer's instructions for...

  20. Four years of Landsat-7 on-orbit geometric calibration and performance

    USGS Publications Warehouse

    Lee, D.S.; Storey, James C.; Choate, M.J.; Hayes, R.W.

    2004-01-01

    Unlike its predecessors, Landsat-7 has undergone regular geometric and radiometric performance monitoring and calibration since launch in April 1999. This ongoing activity, which includes issuing quarterly updates to calibration parameters, has generated a wealth of geometric performance data over the four-year on-orbit period of operations. A suite of geometric characterization (measurement and evaluation procedures) and calibration (procedures to derive improved estimates of instrument parameters) methods are employed by the Landsat-7 Image Assessment System to maintain the geometric calibration and to track specific aspects of geometric performance. These include geodetic accuracy, band-to-band registration accuracy, and image-to-image registration accuracy. These characterization and calibration activities maintain image product geometric accuracy at a high level - by monitoring performance to determine when calibration is necessary, generating new calibration parameters, and verifying that new parameters achieve desired improvements in accuracy. Landsat-7 continues to meet and exceed all geometric accuracy requirements, although aging components have begun to affect performance.

  1. 40 CFR 205.174 - Remedial orders.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... calibrated with the acoustic calibrator as often as is necessary throughout testing to maintain the accuracy... TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycle Exhaust Systems § 205.174 Remedial orders. The... Noise Emission Test Procedures Appendix I-1 to Subparts D and E—Test Procedure for Street and off-road...

  2. About “SI” Traceability of Micromasses And/or Microforces

    NASA Astrophysics Data System (ADS)

    Vâlcu, Adriana; Ştefănescu, Dan Mihai

    Over the last period, increasing attention has been paid to measurement of small forces which play a more important role in nanotechnology and other significant areas such as MEMS (Micro-Electro-Mechanical Systems) and NEMS (nano-electro-mechanical systems) which can be found into everyday products (mobile phones, MP3 players, PCs, cars). In this respect, the development of mass standards and measurement techniques below the current limit of 1 milligram is vital to provide traceability to the SI for such measurements. In Romania, the Mass laboratory of INM considered it necessary to extend the dissemination of the mass unit below 1 mg, in order to meet current needs. Using the subdivision method and starting from the national prototype kilogram No. 2, all necessary experiments were performed for the first time in Romania to extend mass unit traceability till 100 μg. This extension also supports the provision of mass calibrations for low force measurements. The associated measurement procedure and measurement uncertainty results obtained in the calibration are described. In the article are also presented some of the worldwide methods currently used for measuring small forces.

  3. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guillot, Mathieu; Gingras, Luc; Archambault, Louis

    2011-04-15

    Purpose: The purposes of this work were: (1) To determine if a spectral method can accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for situations where the Cerenkov light is dominant over the scintillation light and (2) to develop a procedural guideline for accurately determining the calibration factors of PSDs. Methods: The authors demonstrate, by using the equations of the spectral method, that the condition for accurately correcting the effect of Cerenkov light is that the ratio of the two calibration factors must be equal to the ratio of the Cerenkov light measured within the two differentmore » spectral regions used for analysis. Based on this proof, the authors propose two new procedures to determine the calibration factors of PSDs, which were designed to respect this condition. A PSD that consists of a cylindrical polystyrene scintillating fiber (1.6 mm{sup 3}) coupled to a plastic optical fiber was calibrated by using these new procedures and the two reference procedures described in the literature. To validate the extracted calibration factors, relative dose profiles and output factors for a 6 MV photon beam from a medical linac were measured with the PSD and an ionization chamber. Emphasis was placed on situations where the Cerenkov light is dominant over the scintillation light and on situations dissimilar to the calibration conditions. Results: The authors found that the accuracy of the spectral method depends on the procedure used to determine the calibration factors of the PSD and on the attenuation properties of the optical fiber used. The results from the relative dose profile measurements showed that the spectral method can correct the Cerenkov light effect with an accuracy level of 1%. The results obtained also indicate that PSDs measure output factors that are lower than those measured with ionization chambers for square field sizes larger than 25x25 cm{sup 2}, in general agreement with previously published Monte Carlo results. Conclusions: The authors conclude that the spectral method can be used to accurately correct the Cerenkov light effect in PSDs. The authors confirmed the importance of maximizing the difference of Cerenkov light production between calibration measurements. The authors also found that the attenuation of the optical fiber, which is assumed to be constant in the original formulation of the spectral method, may cause a variation of the calibration factors in some experimental setups.« less

  4. 40 CFR 86.125-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Methane analyzer calibration. 86.125... Complete Heavy-Duty Vehicles; Test Procedures § 86.125-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the...

  5. 40 CFR 86.125-94 - Methane analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Methane analyzer calibration. 86.125... Complete Heavy-Duty Vehicles; Test Procedures § 86.125-94 Methane analyzer calibration. Prior to introduction into service and monthly thereafter, the methane analyzer shall be calibrated: (a) Follow the...

  6. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION, AND MAINTENANCE OF THE THERMO JARRELL ASH ICAP 61-975 PLASMA ATOMCOMP EMISSION SPECTROMETER (BCO-L-8.0)

    EPA Science Inventory

    The purpose of this SOP is to detail the procedures for the start-up, operation, calibration, shut-down, and maintenance of the Thermo Jarrell Ash ICAP 61-975 Plasma AtomComp Emission Spectrometer. These procedures were used in determining the trace target metals Al, As, Ba, Cd,...

  7. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit.

    PubMed

    Poitout, V; Moatti-Sirat, D; Reach, G; Zhang, Y; Wilson, G S; Lemonnier, F; Klein, J C

    1993-07-01

    We have developed a miniaturized glucose sensor which has been shown previously to function adequately when implanted in the subcutaneous tissue of rats and dogs. Following a glucose load, the sensor output increases, making it possible to calculate a sensitivity coefficient to glucose in vivo, and an extrapolated background current in the absence of glucose. These parameters are used for estimating at any time the apparent subcutaneous glucose concentration from the current. In the previous studies, this calibration was performed a posteriori, on the basis of the retrospective analysis of the changes in blood glucose and in the current generated by the sensor. However, for clinical application of the system, an on line estimation of glucose concentration would be necessary. Thus, this study was undertaken in order to assess the possibility of calibrating the sensor in real time, using a novel calibration procedure and a monitoring unit which was specifically designed for this purpose. This electronic device is able to measure, to filter and to store the current. During an oral glucose challenge, when a stable current is reached, it is possible to feed the unit with two different values of blood glucose and their corresponding times. The unit calculates the in vivo parameters, transforms every single value of current into an estimation of the glucose concentration, and then displays this estimation. In this study, 11 sensors were investigated of which two did not respond to glucose. In the other nine trials, the volunteers were asked to record every 30 s what appeared on the display during the secondary decrease in blood glucose.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. 40 CFR 91.316 - Hydrocarbon analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operating adjustment using the appropriate fuel (see § 91.312) and purified synthetic air or zero-grade nitrogen. (2) One of the following procedures is required for FID or HFID optimization: (i) The procedure...) Initial and periodic calibration. Prior to introduction into service and monthly thereafter, or within one...

  9. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.8 Procedure... radiation pyrometer. Repeat for each temperature. (b) Total heat flux meter. The total flux meter shall be... meter. This latter calibration shall make use of the radiant panel tester as the heat source...

  10. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.8 Procedure... radiation pyrometer. Repeat for each temperature. (b) Total heat flux meter. The total flux meter shall be... meter. This latter calibration shall make use of the radiant panel tester as the heat source...

  11. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.8 Procedure... radiation pyrometer. Repeat for each temperature. (b) Total heat flux meter. The total flux meter shall be... meter. This latter calibration shall make use of the radiant panel tester as the heat source...

  12. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.8 Procedure... radiation pyrometer. Repeat for each temperature. (b) Total heat flux meter. The total flux meter shall be... meter. This latter calibration shall make use of the radiant panel tester as the heat source...

  13. Remote Calibration Procedure and Results for the Ctbto AS109 STS-2HG at Ybh

    NASA Astrophysics Data System (ADS)

    Uhrhammer, R. A.; Taira, T.; Hellweg, M.

    2013-12-01

    Berkeley Digital Seismic Station (BDSN) YBH, located in Yreka, CA, USA, is certified as Auxiliary Seismic Station 109 (AS109) by the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty organization (CTBTO). YBH, sited in an abandoned hard rock mining drift, houses a Streckeisen STS-2HG triaxial broadband seismometer (the AS109 sensor) and a co-sited three-component set of Streckeisen STS-1 broadband seismometers and a Kinemetrics Episensor strong motion accelerometer (the BDSN sensors). CTBTO requested that we preform a remote calibration test of the STS-2HG (20,000 V/(m/s) nominal sensitivity) to verify its response and sensitivity. The remote calibration test was done successfully on June 17, 2013 and we report here on the procedure and results of the calibration. The calibration of the STS-2HG (s/n 30235) was accomplished using two Random Telegraph (RT) stimuli which were applied to the triaxial U,V,W component calibration coils through an appropriate series resistance to limit the drive current. The first was a four hour RT at 1.25 Hz (to determine the low-frequency response) and the second was a one hour RT at 25 Hz (to determine the high-frequency response). The RT stimulus signals were generated by the Kinemetrics Q330 data logger and both the stimuli and the response were recorded simultaneously with synchronous sampling at 100 sps. The RT calibrations were invoked remotely from Berkeley. The response to the 1.25 Hz RT stimulus was used to determine the seismometer natural period, fraction of critical damping and sensitivity of the STS-2HG sensors and the response to the 25 Hz RT stimulus was used to determine their corresponding high-frequency response. The accuracy of the sensitivity as determined by the response to the RT stimuli is limited by the accuracy of the calibration coil motor constant (2 g/A) provided on the factory calibration sheet. As a check on the accuracy of the sensitivity determined from the response to the RT stimuli, we also compare the ground motions inferred from the STS-2HG with the corresponding ground motions inferred from the co-sited STS-1's and the Episensor strong motion accelerometer using seismic signals which have adequate signal-to-noise ratios in passband common to both instruments.

  14. Calibration and Data Efforts of the National Ecological Observatory Network (NEON) Airborne Observation Platform during its Engineering Development Phase

    NASA Astrophysics Data System (ADS)

    Adler, J.; Goulden, T.; Kampe, T. U.; Leisso, N.; Musinsky, J.

    2014-12-01

    The National Ecological Observatory Network (NEON) has collected airborne photographic, lidar, and imaging spectrometer data in 5 of 20 unique ecological climate regions (domains) within the United States. As part of its mission to detect and forecast ecological change at continental scales over multiple decades, NEON Airborne Observation Platform (AOP) will aerially survey the entire network of 60 core and re-locatable terrestrial sites annually, each of which are a minimum of 10km-by-10km in extent. The current effort encompasses three years of AOP engineering test flights; in 2017 NEON will transition to full operational status in all 20 domains. To date the total airborne data collected spans 34 Terabytes, and three of the five sampled domain's L1 data are publically available upon request. The large volume of current data, and the expected data collection over the remaining 15 domains, is challenging NEON's data distribution plans, backup capability, and data discovery processes. To provide the public with the highest quality data, calibration and validation efforts of the camera, lidar, and spectrometer L0 data are implemented to produce L1 datasets. Where available, the collected airborne measurements are validated against ground reference points and surfaces and adjusted for instrumentation and atmospheric effects. The imaging spectrometer data is spectrally and radiometrically corrected using NIST-traceable procedures. This presentation highlights three years of flight operation experiences including:1) Lessons learned on payload re-configuration, data extraction, data distribution, permitting requirements, flight planning, and operational procedures2) Lidar validation through control data comparisons collected at the Boulder Municipal Airport (KBDU), the site of NEON's new hangar facility3) Spectrometer calibration efforts, to include both the laboratory and ground observations

  15. Sensitivity Study of the Wall Interference Correction System (WICS) for Rectangular Tunnels

    NASA Technical Reports Server (NTRS)

    Walker, Eric L.; Everhart, Joel L.; Iyer, Venkit

    2001-01-01

    An off-line version of the Wall Interference Correction System (WICS) has been implemented for the NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for Mach numbers less than 0.45 due to a limitation in tunnel calibration data. A study to assess output sensitivity to measurement uncertainty was conducted to determine standard operational procedures and guidelines to ensure data quality during the testing process. Changes to the current facility setup and design recommendations for installing the WICS code into a new facility are reported.

  16. The Sixth SeaWiFS/SIMBIOS Intercalibration Round-Robin Experiment (SIRREX-6)

    NASA Technical Reports Server (NTRS)

    Riley, Thomas; Bailey, Sean

    1998-01-01

    For the sixth Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-6), NASA personnel carried the same four Satlantic in-water radiometers to nine separate laboratories and calibrated them. Two of the sensors were seven-channel radiance heads and two were seven-channel irradiance heads. The calibration and data reduction procedures used at each site followed that laboratory's normal procedures. The reference lamps normally used for the calibration of these types of instruments by the various laboratories were also used for this experiment. NASA personnel processed the data to produce calibration parameters from the various laboratories

  17. Parameter estimation procedure for complex non-linear systems: calibration of ASM No. 1 for N-removal in a full-scale oxidation ditch.

    PubMed

    Abusam, A; Keesman, K J; van Straten, G; Spanjers, H; Meinema, K

    2001-01-01

    When applied to large simulation models, the process of parameter estimation is also called calibration. Calibration of complex non-linear systems, such as activated sludge plants, is often not an easy task. On the one hand, manual calibration of such complex systems is usually time-consuming, and its results are often not reproducible. On the other hand, conventional automatic calibration methods are not always straightforward and often hampered by local minima problems. In this paper a new straightforward and automatic procedure, which is based on the response surface method (RSM) for selecting the best identifiable parameters, is proposed. In RSM, the process response (output) is related to the levels of the input variables in terms of a first- or second-order regression model. Usually, RSM is used to relate measured process output quantities to process conditions. However, in this paper RSM is used for selecting the dominant parameters, by evaluating parameters sensitivity in a predefined region. Good results obtained in calibration of ASM No. 1 for N-removal in a full-scale oxidation ditch proved that the proposed procedure is successful and reliable.

  18. A New Approach to the Internal Calibration of Reverberation-Mapping Spectra

    NASA Astrophysics Data System (ADS)

    Fausnaugh, M. M.

    2017-02-01

    We present a new procedure for the internal (night-to-night) calibration of timeseries spectra, with specific applications to optical AGN reverberation mapping data. The traditional calibration technique assumes that the narrow [O iii] λ5007 emission-line profile is constant in time; given a reference [O iii] λ5007 line profile, nightly spectra are aligned by fitting for a wavelength shift, a flux rescaling factor, and a change in the spectroscopic resolution. We propose the following modifications to this procedure: (1) we stipulate a constant spectral resolution for the final calibrated spectra, (2) we employ a more flexible model for changes in the spectral resolution, and (3) we use a Bayesian modeling framework to assess uncertainties in the calibration. In a test case using data for MCG+08-11-011, these modifications result in a calibration precision of ˜1 millimagnitude, which is approximately a factor of five improvement over the traditional technique. At this level, other systematic issues (e.g., the nightly sensitivity functions and Feii contamination) limit the final precision of the observed light curves. We implement this procedure as a python package (mapspec), which we make available to the community.

  19. Velocity precision measurements using laser Doppler anemometry

    NASA Astrophysics Data System (ADS)

    Dopheide, D.; Taux, G.; Narjes, L.

    1985-07-01

    A Laser Doppler Anemometer (LDA) was calibrated to determine its applicability to high pressure measurements (up to 10 bars) for industrial purposes. The measurement procedure with LDA and the experimental computerized layouts are presented. The calibration procedure is based on absolute accuracy of Doppler frequency and calibration of interference strip intervals. A four-quadrant detector allows comparison of the interference strip distance measurements and computer profiles. Further development of LDA is recommended to increase accuracy (0.1% inaccuracy) and to apply the method industrially.

  20. 40 CFR 86.124-78 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon dioxide analyzer calibration... Complete Heavy-Duty Vehicles; Test Procedures § 86.124-78 Carbon dioxide analyzer calibration. Prior to its introduction into service and monthly thereafter the NDIR carbon dioxide analyzer shall be calibrated: (a...

  1. 40 CFR 86.124-78 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Carbon dioxide analyzer calibration... Complete Heavy-Duty Vehicles; Test Procedures § 86.124-78 Carbon dioxide analyzer calibration. Prior to its introduction into service and monthly thereafter the NDIR carbon dioxide analyzer shall be calibrated: (a...

  2. 40 CFR 86.124-78 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Carbon dioxide analyzer calibration... Complete Heavy-Duty Vehicles; Test Procedures § 86.124-78 Carbon dioxide analyzer calibration. Prior to its introduction into service and monthly thereafter the NDIR carbon dioxide analyzer shall be calibrated: (a...

  3. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  4. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  5. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  6. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  7. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  8. 40 CFR 86.516-90 - Calibrations, frequency and overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be checked at a frequency consistent with observed column life or when the indicator of the column... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.516-90 Calibrations, frequency and...) At least monthly or after any maintenance which could alter calibration, the following calibrations...

  9. 40 CFR 86.516-90 - Calibrations, frequency and overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be checked at a frequency consistent with observed column life or when the indicator of the column... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.516-90 Calibrations, frequency and...) At least monthly or after any maintenance which could alter calibration, the following calibrations...

  10. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

    PubMed

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2015-09-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

  11. Validation and calibration of structural models that combine information from multiple sources.

    PubMed

    Dahabreh, Issa J; Wong, John B; Trikalinos, Thomas A

    2017-02-01

    Mathematical models that attempt to capture structural relationships between their components and combine information from multiple sources are increasingly used in medicine. Areas covered: We provide an overview of methods for model validation and calibration and survey studies comparing alternative approaches. Expert commentary: Model validation entails a confrontation of models with data, background knowledge, and other models, and can inform judgments about model credibility. Calibration involves selecting parameter values to improve the agreement of model outputs with data. When the goal of modeling is quantitative inference on the effects of interventions or forecasting, calibration can be viewed as estimation. This view clarifies issues related to parameter identifiability and facilitates formal model validation and the examination of consistency among different sources of information. In contrast, when the goal of modeling is the generation of qualitative insights about the modeled phenomenon, calibration is a rather informal process for selecting inputs that result in model behavior that roughly reproduces select aspects of the modeled phenomenon and cannot be equated to an estimation procedure. Current empirical research on validation and calibration methods consists primarily of methodological appraisals or case-studies of alternative techniques and cannot address the numerous complex and multifaceted methodological decisions that modelers must make. Further research is needed on different approaches for developing and validating complex models that combine evidence from multiple sources.

  12. Improved infra-red procedure for the evaluation of calibrating units.

    DOT National Transportation Integrated Search

    2011-01-04

    Introduction. The NHTSA Model Specifications for Calibrating Units for Breath : Alcohol Testers (FR 72 34742-34748) requires that calibration units submitted for : inclusion on the NHTSA Conforming Products List for such devices be evaluated using : ...

  13. Wind Tunnel Balance Calibration: Are 1,000,000 Data Points Enough?

    NASA Technical Reports Server (NTRS)

    Rhew, Ray D.; Parker, Peter A.

    2016-01-01

    Measurement systems are typically calibrated based on standard practices established by a metrology standards laboratory, for example the National Institute for Standards and Technology (NIST), or dictated by an organization's metrology manual. Therefore, the calibration is designed and executed according to an established procedure. However, for many aerodynamic research measurement systems a universally accepted standard, traceable approach does not exist. Therefore, a strategy for how to develop a calibration protocol is left to the developer or user to define based on experience and recommended practice in their respective industry. Wind tunnel balances are one such measurement system. Many different calibration systems, load schedules and procedures have been developed for balances with little consensus on a recommended approach. Especially lacking is guidance the number of calibration data points needed. Regrettably, the number of data points tends to be correlated with the perceived quality of the calibration. Often, the number of data points is associated with ones ability to generate the data rather than by a defined need in support of measurement objectives. Hence the title of the paper was conceived to challenge recent observations in the wind tunnel balance community that shows an ever increasing desire for more data points per calibration absent of guidance to determine when there are enough. This paper presents fundamental concepts and theory to aid in the development of calibration procedures for wind tunnel balances and provides a framework that is generally applicable to the characterization and calibration of other measurement systems. Questions that need to be answered are for example: What constitutes an adequate calibration? How much data are needed in the calibration? How good is the calibration? This paper will assist a practitioner in answering these questions by presenting an underlying theory on how to evaluate a calibration based on objective measures. This will enable the developer and user to design calibrations with quantified performance in terms of their capability to meet the user's objectives and a basis for comparing existing calibrations that may have been developed in an ad-hoc manner.

  14. [Fundamental aspects for accrediting medical equipment calibration laboratories in Colombia].

    PubMed

    Llamosa-Rincón, Luis E; López-Isaza, Giovanni A; Villarreal-Castro, Milton F

    2010-02-01

    Analysing the fundamental methodological aspects which should be considered when drawing up calibration procedure for electro-medical equipment, thereby permitting international standard-based accreditation of electro-medical metrology laboratories in Colombia. NTC-ISO-IEC 17025:2005 and GTC-51-based procedures for calibrating electro-medical equipment were implemented and then used as patterns. The mathematical model for determining the estimated uncertainty value when calibrating electro-medical equipment for accreditation by the Electrical Variable Metrology Laboratory's Electro-medical Equipment Calibration Area accredited in compliance with Superintendence of Industry and Commerce Resolution 25771 May 26th 2009 consists of two equations depending on the case; they are: E = (Ai + sigmaAi) - (Ar + sigmaAr + deltaAr1) and E = (Ai + sigmaAi) - (Ar + sigmaA + deltaAr1). The mathematical modelling implemented for measuring uncertainty in the Universidad Tecnológica de Pereira's Electrical Variable Metrology Laboratory (Electro-medical Equipment Calibration Area) will become a good guide for calibration initiated in other laboratories in Colombia and Latin-America.

  15. Evaluation of commercially available techniques and development of simplified methods for measuring grille airflows in HVAC systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain S.; Wray, Craig P.; Guillot, Cyril

    2003-08-01

    In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accuratemore » as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.« less

  16. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CALIBRATION AND OPERATION OF BALANCES (UA-L-1.2)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures used when calibrating and operating balances during the Arizona NHEXAS project and the "Border" study. Keywords: lab; equipment; balances.

    The National Human Exposure Assessment Survey (NHEXAS) is a federal interagency rese...

  17. Application of the Reference Method Isotope Dilution Gas Chromatography Mass Spectrometry (ID/GC/MS) to Establish Metrological Traceability for Calibration and Control of Blood Glucose Test Systems

    PubMed Central

    Andreis, Elisabeth; Küllmer, Kai

    2014-01-01

    Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614

  18. Cross modality registration of video and magnetic tracker data for 3D appearance and structure modeling

    NASA Astrophysics Data System (ADS)

    Sargent, Dusty; Chen, Chao-I.; Wang, Yuan-Fang

    2010-02-01

    The paper reports a fully-automated, cross-modality sensor data registration scheme between video and magnetic tracker data. This registration scheme is intended for use in computerized imaging systems to model the appearance, structure, and dimension of human anatomy in three dimensions (3D) from endoscopic videos, particularly colonoscopic videos, for cancer research and clinical practices. The proposed cross-modality calibration procedure operates this way: Before a colonoscopic procedure, the surgeon inserts a magnetic tracker into the working channel of the endoscope or otherwise fixes the tracker's position on the scope. The surgeon then maneuvers the scope-tracker assembly to view a checkerboard calibration pattern from a few different viewpoints for a few seconds. The calibration procedure is then completed, and the relative pose (translation and rotation) between the reference frames of the magnetic tracker and the scope is determined. During the colonoscopic procedure, the readings from the magnetic tracker are used to automatically deduce the pose (both position and orientation) of the scope's reference frame over time, without complicated image analysis. Knowing the scope movement over time then allows us to infer the 3D appearance and structure of the organs and tissues in the scene. While there are other well-established mechanisms for inferring the movement of the camera (scope) from images, they are often sensitive to mistakes in image analysis, error accumulation, and structure deformation. The proposed method using a magnetic tracker to establish the camera motion parameters thus provides a robust and efficient alternative for 3D model construction. Furthermore, the calibration procedure does not require special training nor use expensive calibration equipment (except for a camera calibration pattern-a checkerboard pattern-that can be printed on any laser or inkjet printer).

  19. PSA discriminator influence on (222)Rn efficiency detection in waters by liquid scintillation counting.

    PubMed

    Stojković, Ivana; Todorović, Nataša; Nikolov, Jovana; Tenjović, Branislava

    2016-06-01

    A procedure for the (222)Rn determination in aqueous samples using liquid scintillation counting (LSC) was evaluated and optimized. Measurements were performed by ultra-low background spectrometer Quantulus 1220™ equipped with PSA (Pulse Shape Analysis) circuit which discriminates alpha/beta spectra. Since calibration procedure is carried out with (226)Ra standard, which has both alpha and beta progenies, it is clear that PSA discriminator has vital importance in order to provide precise spectra separation. Improvement of calibration procedure was done through investigation of PSA discriminator level and, consequentially, the activity of (226)Ra calibration standard influence on (222)Rn efficiency detection. Quench effects on generated spectra i.e. determination of radon efficiency detection were also investigated with quench calibration curve obtained. Radon determination in waters based on modified procedure according to the activity of (226)Ra standard used, dependent on PSA setup, was evaluated with prepared (226)Ra solution samples and drinking water samples with assessment of measurement uncertainty variation included. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Dual echelon femtosecond single-shot spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Taeho; Wolfson, Johanna W.; Teitelbaum, Samuel W.

    We have developed a femtosecond single-shot spectroscopic technique to measure irreversible changes in condensed phase materials in real time. Crossed echelons generate a two-dimensional array of time-delayed pulses with one femtosecond probe pulse. This yields 9 ps of time-resolved data from a single laser shot, filling a gap in currently employed measurement methods. We can now monitor ultrafast irreversible dynamics in solid-state materials or other samples that cannot be flowed or replenished between laser shots, circumventing limitations of conventional pump-probe methods due to sample damage or product buildup. Despite the absence of signal-averaging in the single-shot measurement, an acceptable signal-to-noisemore » level has been achieved via background and reference calibration procedures. Pump-induced changes in relative reflectivity as small as 0.2%−0.5% are demonstrated in semimetals, with both electronic and coherent phonon dynamics revealed by the data. The optical arrangement and the space-to-time conversion and calibration procedures necessary to achieve this level of operation are described. Sources of noise and approaches for dealing with them are discussed.« less

  1. Building Energy Simulation Test for Existing Homes (BESTEST-EX) (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Judkoff, R.; Neymark, J.; Polly, B.

    2011-12-01

    This presentation discusses the goals of NREL Analysis Accuracy R&D; BESTEST-EX goals; what BESTEST-EX is; how it works; 'Building Physics' cases; 'Building Physics' reference results; 'utility bill calibration' cases; limitations and potential future work. Goals of NREL Analysis Accuracy R&D are: (1) Provide industry with the tools and technical information needed to improve the accuracy and consistency of analysis methods; (2) Reduce the risks associated with purchasing, financing, and selling energy efficiency upgrades; and (3) Enhance software and input collection methods considering impacts on accuracy, cost, and time of energy assessments. BESTEST-EX Goals are: (1) Test software predictions of retrofitmore » energy savings in existing homes; (2) Ensure building physics calculations and utility bill calibration procedures perform up to a minimum standard; and (3) Quantify impact of uncertainties in input audit data and occupant behavior. BESTEST-EX is a repeatable procedure that tests how well audit software predictions compare to the current state of the art in building energy simulation. There is no direct truth standard. However, reference software have been subjected to validation testing, including comparisons with empirical data.« less

  2. How [NOT] to Measure a Solar Cell to Get the Highest Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The multibillion-dollar photovoltaic (PV) industry sells products by the watt; the calibration labs measure this parameter at the cell and module level with the lowest possible uncertainty of 1-2 percent. The methods and procedures to achieve a measured 50 percent efficiency on a thin-film solar cell are discussed. This talk will describe methods that ignore procedures that increase the uncertainty. Your questions will be answered concerning 'Everything you Always Wanted to Know about Efficiency Enhancements But Were Afraid to Ask.' The talk will cover a step-by-step procedure using examples found in literature or encountered in customer samples by the Nationalmore » Renewable Energy Laboratory's (NREL's) PV Performance Characterization Group on how to artificially enhance the efficiency. The procedures will describe methods that have been used to enhance the current voltage and fill factor.« less

  3. 40 CFR 92.121 - Oxides of nitrogen analyzer calibration and check.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Oxides of nitrogen analyzer calibration... Procedures § 92.121 Oxides of nitrogen analyzer calibration and check. (a) Quench checks; NO X analyzer. (1... performed in step in paragraph (a)(3)(i) this section. (b) Oxides of nitrogen analyzer calibration. (1...

  4. Issues concerning international comparison of free-field calibrations of acoustical standards

    NASA Astrophysics Data System (ADS)

    Nedzelnitsky, Victor

    2002-11-01

    Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.

  5. Statistical photocalibration of photodetectors for radiometry without calibrated light sources

    NASA Astrophysics Data System (ADS)

    Yielding, Nicholas J.; Cain, Stephen C.; Seal, Michael D.

    2018-01-01

    Calibration of CCD arrays for identifying bad pixels and achieving nonuniformity correction is commonly accomplished using dark frames. This kind of calibration technique does not achieve radiometric calibration of the array since only the relative response of the detectors is computed. For this, a second calibration is sometimes utilized by looking at sources with known radiances. This process can be used to calibrate photodetectors as long as a calibration source is available and is well-characterized. A previous attempt at creating a procedure for calibrating a photodetector using the underlying Poisson nature of the photodetection required calculations of the skewness of the photodetector measurements. Reliance on the third moment of measurement meant that thousands of samples would be required in some cases to compute that moment. A photocalibration procedure is defined that requires only first and second moments of the measurements. The technique is applied to image data containing a known light source so that the accuracy of the technique can be surmised. It is shown that the algorithm can achieve accuracy of nearly 2.7% of the predicted number of photons using only 100 frames of image data.

  6. Calibration of Viking imaging system pointing, image extraction, and optical navigation measure

    NASA Technical Reports Server (NTRS)

    Breckenridge, W. G.; Fowler, J. W.; Morgan, E. M.

    1977-01-01

    Pointing control and knowledge accuracy of Viking Orbiter science instruments is controlled by the scan platform. Calibration of the scan platform and the imaging system was accomplished through mathematical models. The calibration procedure and results obtained for the two Viking spacecraft are described. Included are both ground and in-flight scan platform calibrations, and the additional calibrations unique to optical navigation.

  7. Improving the Traceability of Meteorological Measurements at Automatic Weather Stations in Thailand

    NASA Astrophysics Data System (ADS)

    Keawprasert, T.; Sinhaneti, T.; Phuuntharo, P.; Phanakulwijit, S.; Nimsamer, A.

    2017-08-01

    A joint project between the National Institute of Metrology Thailand (NIMT) and the Thai Meteorology Department (TMD) was established for improving the traceability of meteorology measurements at automatic weather stations (AWSs) in Thailand. The project aimed to improve traceability of air temperature, relative humidity and atmospheric pressure by implementing on-site calibration facilities and developing of new calibration procedures. First, new portable calibration facilities for air temperature, humidity and pressure were set up as working standard of the TMD. A portable humidity calibrator was applied as a uniform and stable source for calibration of thermo-hygrometers. A dew-point hygrometer was employed as reference hygrometer and a platinum resistance thermometer (PRT) traceable to NIMT was used as reference thermometer. The uniformity and stability in both temperature and relative humidity were characterized at NIMT. A transportable pressure calibrator was used for calibration of air pressure sensor. The estimate overall uncertainty of the calibration setup is 0.2 K for air temperature, 1.0 % for relative humidity and 0.2 hPa for atmospheric pressure, respectively. Second, on-site calibration procedures were developed and four AWSs in the central part and the northern of Thailand were chosen as pilot stations for on-site calibration using the new calibration setups and developed calibration procedures. At each station, the calibration was done at the minimum temperature, average temperature and maximum temperature of the year, for air temperature, 20 %, 55 % and 90 % for relative humidity at the average air temperature of that station and at a one-year statistics pressure range for atmospheric pressure at ambient temperature. Additional in-field uncertainty contributions such as the temperature dependence on relative humidity measurement were evaluated and included in the overall uncertainty budget. Preliminary calibration results showed that using a separate PRT probe at these AWSs would be recommended for improving the accuracy of air temperature measurement. In case of relative humidity measurement, the data logger software is needed to be upgraded for achieving higher accuracy of less than 3 %. For atmospheric pressure measurement, a higher accuracy barometer traceable to NIMT could be used to reduce the calibration uncertainty to below 0.2 hPa.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Wei; Balkovic, Juraj; van der Velde, M.

    Crop models are increasingly used to assess impacts of climate change/variability and management practices on productivity and environmental performance of alternative cropping systems. Calibration is an important procedure to improve reliability of model simulations, especially for large area applications. However, global-scale crop model calibration has rarely been exercised due to limited data availability and expensive computing cost. Here we present a simple approach to calibrate Environmental Policy Integrated Climate (EPIC) model for a global implementation of rice. We identify four parameters (potential heat unit – PHU, planting density – PD, harvest index – HI, and biomass energy ratio – BER)more » and calibrate them regionally to capture the spatial pattern of reported rice yield in 2000. Model performance is assessed by comparing simulated outputs with independent FAO national data. The comparison demonstrates that the global calibration scheme performs satisfactorily in reproducing the spatial pattern of rice yield, particularly in main rice production areas. Spatial agreement increases substantially when more parameters are selected and calibrated, but with varying efficiencies. Among the parameters, PHU and HI exhibit the highest efficiencies in increasing the spatial agreement. Simulations with different calibration strategies generate a pronounced discrepancy of 5–35% in mean yields across latitude bands, and a small to moderate difference in estimated yield variability and yield changing trend for the period of 1981–2000. Present calibration has little effects in improving simulated yield variability and trends at both regional and global levels, suggesting further works are needed to reproduce temporal variability of reported yields. This study highlights the importance of crop models’ calibration, and presents the possibility of a transparent and consistent up scaling approach for global crop simulations given current availability of global databases of weather, soil, crop calendar, fertilizer and irrigation management information, and reported yield.« less

  9. Calibration of Low Cost Digital Camera Using Data from Simultaneous LIDAR and Photogrammetric Surveys

    NASA Astrophysics Data System (ADS)

    Mitishita, E.; Debiasi, P.; Hainosz, F.; Centeno, J.

    2012-07-01

    Digital photogrammetric products from the integration of imagery and lidar datasets are a reality nowadays. When the imagery and lidar surveys are performed together and the camera is connected to the lidar system, a direct georeferencing can be applied to compute the exterior orientation parameters of the images. Direct georeferencing of the images requires accurate interior orientation parameters to perform photogrammetric application. Camera calibration is a procedure applied to compute the interior orientation parameters (IOPs). Calibration researches have established that to obtain accurate IOPs, the calibration must be performed with same or equal condition that the photogrammetric survey is done. This paper shows the methodology and experiments results from in situ self-calibration using a simultaneous images block and lidar dataset. The calibration results are analyzed and discussed. To perform this research a test field was fixed in an urban area. A set of signalized points was implanted on the test field to use as the check points or control points. The photogrammetric images and lidar dataset of the test field were taken simultaneously. Four strips of flight were used to obtain a cross layout. The strips were taken with opposite directions of flight (W-E, E-W, N-S and S-N). The Kodak DSC Pro SLR/c digital camera was connected to the lidar system. The coordinates of the exposition station were computed from the lidar trajectory. Different layouts of vertical control points were used in the calibration experiments. The experiments use vertical coordinates from precise differential GPS survey or computed by an interpolation procedure using the lidar dataset. The positions of the exposition stations are used as control points in the calibration procedure to eliminate the linear dependency of the group of interior and exterior orientation parameters. This linear dependency happens, in the calibration procedure, when the vertical images and flat test field are used. The mathematic correlation of the interior and exterior orientation parameters are analyzed and discussed. The accuracies of the calibration experiments are, as well, analyzed and discussed.

  10. Qualification of the RSRM field joint CF case-to-insulation bondline inspection using the Thiokol Corporation ultrasonic RSRM bondline inspection system

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1990-01-01

    Qualification testing of Combustion Engineering's AMDATA Intraspect/98 Data Acquisition and Imaging System that applies to the redesigned solid rocket motor field joint capture feature case-to-insulation bondline inspection was performed. Testing was performed at M-111, the Thiokol Corp. Inert Parts Preparation Building. The purpose of the inspection was to verify the integrity of the capture feature area case-to-insulation bondline. The capture feature scanner was calibrated over an intentional 1.0 to 1.0 in. case-to-insulation unbond. The capture feature scanner was then used to scan 60 deg of a capture feature field joint. Calibration of the capture feature scanner was then rechecked over the intentional unbond to ensure that the calibration settings did not change during the case scan. This procedure was successfully performed five times to qualify the unbond detection capability of the capture feature scanner. The capture feature scanner qualified in this test contains many points of mechanical instability that can affect the overall ultrasonic signal response. A new generation scanner, designated the sigma scanner, should be implemented to replace the current configuration scanner. The sigma scanner eliminates the unstable connection points of the current scanner and has additional inspection capabilities.

  11. U.K. National Radiological Protection Board Radon Calibration Procedures

    PubMed Central

    Cliff, K. D.

    1990-01-01

    A procedure for the calibration of instruments for the detection of 222Rn in air is described. The method is based on the alpha-spectrometric determination of the concentration in air of 218Po in the calibration chamber. The calibration chamber is described, together with the method of maintaining a high aerosol concentration. The 218Po concentration at steady state in the chamber is found to be 98% of the 222Rn concentration typically. An assessment of the sources of uncertainty in the method presented indicate that the 222Rn concentration in the chamber can be determined with an overall uncertainty of about 7% at the 95% confidence level. PMID:28179765

  12. L5 TM radiometric recalibration procedure using the internal calibration trends from the NLAPS trending database

    USGS Publications Warehouse

    Chander, G.; Haque, Md. O.; Micijevic, E.; Barsi, J.A.

    2008-01-01

    From the Landsat program's inception in 1972 to the present, the earth science user community has benefited from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time causing radiometric calibration errors up to 20 percent. In May 2003 the National Landsat Archive Production System (NLAPS) was updated to use a gain model rather than the scene acquisition specific IC gains to calibrate TM data processed in the United States. Further modification of the gain model was performed in 2007. L5 TM data that were processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing Level-1 products. The best recalibration results are obtained if the work order report that was originally included in the standard data product delivery is available. However, many users may not have the original work order report. In such cases, the IC gain look-up table that was generated using the radiometric gain trends recorded in the NLAPS database can be used for recalibration. This paper discusses the procedure to recalibrate L5 TM data when the work order report originally used in processing is not available. A companion paper discusses the generation of the NLAPS IC gain and bias look-up tables required to perform the recalibration.

  13. Synthetic aperture imaging in ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Jayaranthe, Uditha L.; Chen, Elvis C. S.; Peters, Terry M.

    2014-03-01

    Ultrasound calibration allows for ultrasound images to be incorporated into a variety of interventional applica­ tions. Traditional Z- bar calibration procedures rely on wired phantoms with an a priori known geometry. The line fiducials produce small, localized echoes which are then segmented from an array of ultrasound images from different tracked probe positions. In conventional B-mode ultrasound, the wires at greater depths appear blurred and are difficult to segment accurately, limiting the accuracy of ultrasound calibration. This paper presents a novel ultrasound calibration procedure that takes advantage of synthetic aperture imaging to reconstruct high resolution ultrasound images at arbitrary depths. In these images, line fiducials are much more readily and accu­ rately segmented, leading to decreased calibration error. The proposed calibration technique is compared to one based on B-mode ultrasound. The fiducial localization error was improved from 0.21mm in conventional B-mode images to 0.15mm in synthetic aperture images corresponding to an improvement of 29%. This resulted in an overall reduction of calibration error from a target registration error of 2.00mm to 1.78mm, an improvement of 11%. Synthetic aperture images display greatly improved segmentation capabilities due to their improved resolution and interpretability resulting in improved calibration.

  14. Project MAGNET High-level Vector Survey Data Reduction

    NASA Technical Reports Server (NTRS)

    Coleman, Rachel J.

    1992-01-01

    Since 1951, the U.S. Navy, under its Project MAGNET program, has been continuously collecting vector aeromagnetic survey data to support the U.S. Defense Mapping Agency's world magnetic and charting program. During this forty-year period, a variety of survey platforms and instrumentation configurations have been used. The current Project MAGNET survey platform is a Navy Orion RP-3D aircraft which has been specially modified and specially equipped with a redundant suite of navigational positioning, attitude, and magnetic sensors. A review of the survey data collection procedures and calibration and editing techniques applied to the data generated by this suite of instrumentation will be presented. Among the topics covered will be the determination of its parameters from the low-level calibration maneuvers flown over geomagnetic observatories.

  15. 40 CFR 1065.330 - Exhaust-flow calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 1065.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Flow-Related Measurements § 1065.330... ultrasonic flow meter for raw exhaust flow measurement, we recommend that you calibrate it as described in...

  16. 40 CFR 1066.130 - Measurement instrument calibrations and verifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Measurement instrument calibrations... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Equipment, Measurement Instruments, Fuel, and Analytical Gas Specifications § 1066.130 Measurement instrument calibrations and verifications. The...

  17. US Army Test and Evaluation Command, Test Operations Procedure, Gamma Ray Source Calibration

    DTIC Science & Technology

    1980-03-28

    SUPPLEMENTARY NOTES Safety, HTP 6-2-507 and AMCR-385-25. Related MTP’s: 8-3-171, AD 871790, 26 May 70 Radiation Detection Equipment 8-3-172, AD 728455, 1...perienced in Radiac calibration equipment and for that reason the procedures are not step-by-step but are planned to be interpreted by the operator in...is to be used by personnel trained and ex- perienced in the use of radiac calibration equipment and radiation prin- ciples. It ognnot be interpreted

  18. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR CALIBRATION AND OPERATION OF NHEXAS BALANCES (UA-L-1.2)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures used when calibrating and operating balances during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment; balances.

    The U.S.-Mexico Border Program is sponsored by the Environmental Health Workgroup of t...

  19. Invasive and non-invasive measurement in medicine and biology: calibration issues

    NASA Astrophysics Data System (ADS)

    Rolfe, P.; Zhang, Yan; Sun, Jinwei; Scopesi, F.; Serra, G.; Yamakoshi, K.; Tanaka, S.; Yamakoshi, T.; Yamakoshi, Y.; Ogawa, M.

    2010-08-01

    Invasive and non-invasive measurement sensors and systems perform vital roles in medical care. Devices are based on various principles, including optics, photonics, and plasmonics, electro-analysis, magnetics, acoustics, bio-recognition, etc. Sensors are used for the direct insertion into the human body, for example to be in contact with blood, which constitutes Invasive Measurement. This approach is very challenging technically, as sensor performance (sensitivity, response time, linearity) can deteriorate due to interactions between the sensor materials and the biological environment, such as blood or interstitial fluid. Invasive techniques may also be potentially hazardous. Alternatively, sensors or devices may be positioned external to the body surface, for example to analyse respired breath, thereby allowing safer Non-Invasive Measurement. However, such methods, which are inherently less direct, often requiring more complex calibration algorithms, perhaps using chemometric principles. This paper considers and reviews the issue of calibration in both invasive and non-invasive biomedical measurement systems. Systems in current use usually rely upon periodic calibration checks being performed by clinical staff against a variety of laboratory instruments and QC samples. These procedures require careful planning and overall management if reliable data are to be assured.

  20. Boresight Calibration of Construction Misalignments for 3D Scanners Built with a 2D Laser Rangefinder Rotating on Its Optical Center

    PubMed Central

    Morales, Jesús; Martínez, Jorge L.; Mandow, Anthony; Reina, Antonio J.; Pequeño-Boter, Alejandro; García-Cerezo, Alfonso

    2014-01-01

    Many applications, like mobile robotics, can profit from acquiring dense, wide-ranging and accurate 3D laser data. Off-the-shelf 2D scanners are commonly customized with an extra rotation as a low-cost, lightweight and low-power-demanding solution. Moreover, aligning the extra rotation axis with the optical center allows the 3D device to maintain the same minimum range as the 2D scanner and avoids offsets in computing Cartesian coordinates. The paper proposes a practical procedure to estimate construction misalignments based on a single scan taken from an arbitrary position in an unprepared environment that contains planar surfaces of unknown dimensions. Inherited measurement limitations from low-cost 2D devices prevent the estimation of very small translation misalignments, so the calibration problem reduces to obtaining boresight parameters. The distinctive approach with respect to previous plane-based intrinsic calibration techniques is the iterative maximization of both the flatness and the area of visible planes. Calibration results are presented for a case study. The method is currently being applied as the final stage in the production of a commercial 3D rangefinder. PMID:25347585

  1. Description of ARCAL XXXIV Project: Repair and Calibration of Electrometers and Ionization Chambers Used in Radiotherapy

    NASA Astrophysics Data System (ADS)

    Cruz-Estrada, P.; Ramírez-Jiménez, F. J.; Villaverde-Lozano, A.

    2003-09-01

    The technological tools for the diagnosis of diseases and treatment of cancer are based mostly on the use of ionizing radiations. This situation worries to the International Atomic Energy Agency (IAEA), which has implemented programs of technical cooperation for the protection of the human health. One of these programs is running in Latin America under the ARCAL project (Regional Agreement of Cooperation for the Promotion of the Nuclear Science and Technology in Latin America and the Caribbean). One objective of the ARCAL XXXIV project is the establishment of three Regional Centres for the repair, maintenance and electrical calibration of clinical dosimeters, in Mexico we have one of these centres. Some other objectives of the project are: the generation of calibration procedures, the release of training courses in the region, the establishment of an inter-comparison network for the region in the control of standards of calibration with electrometers and the design of low current sources that simulates the ionization chamber and can serve as field standards for each of the participant countries. A description of the results of the project is presented in this work.

  2. System calibration method for Fourier ptychographic microscopy

    NASA Astrophysics Data System (ADS)

    Pan, An; Zhang, Yan; Zhao, Tianyu; Wang, Zhaojun; Dan, Dan; Lei, Ming; Yao, Baoli

    2017-09-01

    Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic.

  3. Generic Techniques for the Calibration of Robots with Application of the 3-D Fixtures and Statistical Technique on the PUMA 500 and ARID Robots

    NASA Technical Reports Server (NTRS)

    Tawfik, Hazem

    1991-01-01

    A relatively simple, inexpensive, and generic technique that could be used in both laboratories and some operation site environments is introduced at the Robotics Applications and Development Laboratory (RADL) at Kennedy Space Center (KSC). In addition, this report gives a detailed explanation of the set up procedure, data collection, and analysis using this new technique that was developed at the State University of New York at Farmingdale. The technique was used to evaluate the repeatability, accuracy, and overshoot of the Unimate Industrial Robot, PUMA 500. The data were statistically analyzed to provide an insight into the performance of the systems and components of the robot. Also, the same technique was used to check the forward kinematics against the inverse kinematics of RADL's PUMA robot. Recommendations were made for RADL to use this technique for laboratory calibration of the currently existing robots such as the ASEA, high speed controller, Automated Radiator Inspection Device (ARID) etc. Also, recommendations were made to develop and establish other calibration techniques that will be more suitable for site calibration environment and robot certification.

  4. Precise Haptic Device Co-Location for Visuo-Haptic Augmented Reality.

    PubMed

    Eck, Ulrich; Pankratz, Frieder; Sandor, Christian; Klinker, Gudrun; Laga, Hamid

    2015-12-01

    Visuo-haptic augmented reality systems enable users to see and touch digital information that is embedded in the real world. PHANToM haptic devices are often employed to provide haptic feedback. Precise co-location of computer-generated graphics and the haptic stylus is necessary to provide a realistic user experience. Previous work has focused on calibration procedures that compensate the non-linear position error caused by inaccuracies in the joint angle sensors. In this article we present a more complete procedure that additionally compensates for errors in the gimbal sensors and improves position calibration. The proposed procedure further includes software-based temporal alignment of sensor data and a method for the estimation of a reference for position calibration, resulting in increased robustness against haptic device initialization and external tracker noise. We designed our procedure to require minimal user input to maximize usability. We conducted an extensive evaluation with two different PHANToMs, two different optical trackers, and a mechanical tracker. Compared to state-of-the-art calibration procedures, our approach significantly improves the co-location of the haptic stylus. This results in higher fidelity visual and haptic augmentations, which are crucial for fine-motor tasks in areas such as medical training simulators, assembly planning tools, or rapid prototyping applications.

  5. Calibrating a tensor magnetic gradiometer using spin data

    USGS Publications Warehouse

    Bracken, Robert E.; Smith, David V.; Brown, Philip J.

    2005-01-01

    Scalar magnetic data are often acquired to discern characteristics of geologic source materials and buried objects. It is evident that a great deal can be done with scalar data, but there are significant advantages to direct measurement of the magnetic gradient tensor in applications with nearby sources, such as unexploded ordnance (UXO). To explore these advantages, we adapted a prototype tensor magnetic gradiometer system (TMGS) and successfully implemented a data-reduction procedure. One of several critical reduction issues is the precise determination of a large group of calibration coefficients for the sensors and sensor array. To resolve these coefficients, we devised a spin calibration method, after similar methods of calibrating space-based magnetometers (Snare, 2001). The spin calibration procedure consists of three parts: (1) collecting data by slowly revolving the sensor array in the Earth?s magnetic field, (2) deriving a comprehensive set of coefficients from the spin data, and (3) applying the coefficients to the survey data. To show that the TMGS functions as a tensor gradiometer, we conducted an experimental survey that verified that the reduction procedure was effective (Bracken and Brown, in press). Therefore, because it was an integral part of the reduction, it can be concluded that the spin calibration was correctly formulated with acceptably small errors.

  6. Calibration and evaluation of a dispersant application system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shum, J.S.

    1987-05-01

    The report presents recommended methods for calibrating and operating boat-mounted dispersant application systems. Calibration of one commercially-available system and several unusual problems encountered in calibration are described. Charts and procedures for selecting pump rates and other operating parameters in order to achieve a desired dosage are provided. The calibration was performed at the EPA's Oil and Hazardous Materials Simulated Environmental Test Tank (OHMSETT) facility in Leonardo, New Jersey.

  7. Calibration procedure for Slocum glider deployed optical instruments.

    PubMed

    Cetinić, Ivona; Toro-Farmer, Gerardo; Ragan, Matthew; Oberg, Carl; Jones, Burton H

    2009-08-31

    Recent developments in the field of the autonomous underwater vehicles allow the wide usage of these platforms as part of scientific experiments, monitoring campaigns and more. The vehicles are often equipped with sensors measuring temperature, conductivity, chlorophyll a fluorescence (Chl a), colored dissolved organic matter (CDOM) fluorescence, phycoerithrin (PE) fluorescence and spectral volume scattering function at 117 degrees, providing users with high resolution, real time data. However, calibration of these instruments can be problematic. Most in situ calibrations are performed by deploying complementary instrument packages or water samplers in the proximity of the glider. Laboratory calibrations of the mounted sensors are difficult due to the placement of the instruments within the body of the vehicle. For the laboratory calibrations of the Slocum glider instruments we developed a small calibration chamber where we can perform precise calibrations of the optical instruments aboard our glider, as well as sensors from other deployment platforms. These procedures enable us to obtain pre- and post-deployment calibrations for optical fluorescence instruments, which may differ due to the biofouling and other physical damage that can occur during long-term glider deployments. We found that biofouling caused significant changes in the calibration scaling factors of fluorescent sensors, suggesting the need for consistent and repetitive calibrations for gliders as proposed in this paper.

  8. Electronic test and calibration circuits, a compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.

  9. On combination of strict Bayesian principles with model reduction technique or how stochastic model calibration can become feasible for large-scale applications

    NASA Astrophysics Data System (ADS)

    Oladyshkin, S.; Schroeder, P.; Class, H.; Nowak, W.

    2013-12-01

    Predicting underground carbon dioxide (CO2) storage represents a challenging problem in a complex dynamic system. Due to lacking information about reservoir parameters, quantification of uncertainties may become the dominant question in risk assessment. Calibration on past observed data from pilot-scale test injection can improve the predictive power of the involved geological, flow, and transport models. The current work performs history matching to pressure time series from a pilot storage site operated in Europe, maintained during an injection period. Simulation of compressible two-phase flow and transport (CO2/brine) in the considered site is computationally very demanding, requiring about 12 days of CPU time for an individual model run. For that reason, brute-force approaches for calibration are not feasible. In the current work, we explore an advanced framework for history matching based on the arbitrary polynomial chaos expansion (aPC) and strict Bayesian principles. The aPC [1] offers a drastic but accurate stochastic model reduction. Unlike many previous chaos expansions, it can handle arbitrary probability distribution shapes of uncertain parameters, and can therefore handle directly the statistical information appearing during the matching procedure. We capture the dependence of model output on these multipliers with the expansion-based reduced model. In our study we keep the spatial heterogeneity suggested by geophysical methods, but consider uncertainty in the magnitude of permeability trough zone-wise permeability multipliers. Next combined the aPC with Bootstrap filtering (a brute-force but fully accurate Bayesian updating mechanism) in order to perform the matching. In comparison to (Ensemble) Kalman Filters, our method accounts for higher-order statistical moments and for the non-linearity of both the forward model and the inversion, and thus allows a rigorous quantification of calibrated model uncertainty. The usually high computational costs of accurate filtering become very feasible for our suggested aPC-based calibration framework. However, the power of aPC-based Bayesian updating strongly depends on the accuracy of prior information. In the current study, the prior assumptions on the model parameters were not satisfactory and strongly underestimate the reservoir pressure. Thus, the aPC-based response surface used in Bootstrap filtering is fitted to a distant and poorly chosen region within the parameter space. Thanks to the iterative procedure suggested in [2] we overcome this drawback with small computational costs. The iteration successively improves the accuracy of the expansion around the current estimation of the posterior distribution. The final result is a calibrated model of the site that can be used for further studies, with an excellent match to the data. References [1] Oladyshkin S. and Nowak W. Data-driven uncertainty quantification using the arbitrary polynomial chaos expansion. Reliability Engineering and System Safety, 106:179-190, 2012. [2] Oladyshkin S., Class H., Nowak W. Bayesian updating via Bootstrap filtering combined with data-driven polynomial chaos expansions: methodology and application to history matching for carbon dioxide storage in geological formations. Computational Geosciences, 17 (4), 671-687, 2013.

  10. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

    PubMed Central

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-01

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745

  11. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors.

    PubMed

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-22

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors' radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors' application, and as such will promote the development of Chinese satellite data.

  12. Polarimetric SAR calibration experiment using active radar calibrators

    NASA Astrophysics Data System (ADS)

    Freeman, Anthony; Shen, Yuhsyen; Werner, Charles L.

    1990-03-01

    Active radar calibrators are used to derive both the amplitude and phase characteristics of a multichannel polarimetric SAR from the complex image data. Results are presented from an experiment carried out using the NASA/JPL DC-8 aircraft SAR over a calibration site at Goldstone, California. As part of the experiment, polarimetric active radar calibrators (PARCs) with adjustable polarization signatures were deployed. Experimental results demonstrate that the PARCs can be used to calibrate polarimetric SAR images successfully. Restrictions on the application of the PARC calibration procedure are discussed.

  13. Polarimetric SAR calibration experiment using active radar calibrators

    NASA Technical Reports Server (NTRS)

    Freeman, Anthony; Shen, Yuhsyen; Werner, Charles L.

    1990-01-01

    Active radar calibrators are used to derive both the amplitude and phase characteristics of a multichannel polarimetric SAR from the complex image data. Results are presented from an experiment carried out using the NASA/JPL DC-8 aircraft SAR over a calibration site at Goldstone, California. As part of the experiment, polarimetric active radar calibrators (PARCs) with adjustable polarization signatures were deployed. Experimental results demonstrate that the PARCs can be used to calibrate polarimetric SAR images successfully. Restrictions on the application of the PARC calibration procedure are discussed.

  14. Calibration of High Heat Flux Sensors at NIST

    PubMed Central

    Murthy, A. V.; Tsai, B. K.; Gibson, C. E.

    1997-01-01

    An ongoing program at the National Institute of Standards and Technology (NIST) is aimed at improving and standardizing heat-flux sensor calibration methods. The current calibration needs of U.S. science and industry exceed the current NIST capability of 40 kW/m2 irradiance. In achieving this goal, as well as meeting lower-level non-radiative heat flux calibration needs of science and industry, three different types of calibration facilities currently are under development at NIST: convection, conduction, and radiation. This paper describes the research activities associated with the NIST Radiation Calibration Facility. Two different techniques, transfer and absolute, are presented. The transfer calibration technique employs a transfer standard calibrated with reference to a radiometric standard for calibrating the sensors using a graphite tube blackbody. Plans for an absolute calibration facility include the use of a spherical blackbody and a cooled aperture and sensor-housing assembly to calibrate the sensors in a low convective environment. PMID:27805156

  15. Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera.

    PubMed

    Reyes, Bersain A; Reljin, Natasa; Kong, Youngsun; Nam, Yunyoung; Ha, Sangho; Chon, Ki H

    2016-03-18

    A smartphone-based tidal volume (V(T)) estimator was recently introduced by our research group, where an Android application provides a chest movement signal whose peak-to-peak amplitude is highly correlated with reference V(T) measured by a spirometer. We found a Normalized Root Mean Squared Error (NRMSE) of 14.998% ± 5.171% (mean ± SD) when the smartphone measures were calibrated using spirometer data. However, the availability of a spirometer device for calibration is not realistic outside clinical or research environments. In order to be used by the general population on a daily basis, a simple calibration procedure not relying on specialized devices is required. In this study, we propose taking advantage of the linear correlation between smartphone measurements and V(T) to obtain a calibration model using information computed while the subject breathes through a commercially-available incentive spirometer (IS). Experiments were performed on twelve (N = 12) healthy subjects. In addition to corroborating findings from our previous study using a spirometer for calibration, we found that the calibration procedure using an IS resulted in a fixed bias of -0.051 L and a RMSE of 0.189 ± 0.074 L corresponding to 18.559% ± 6.579% when normalized. Although it has a small underestimation and slightly increased error, the proposed calibration procedure using an IS has the advantages of being simple, fast, and affordable. This study supports the feasibility of developing a portable smartphone-based breathing status monitor that provides information about breathing depth, in addition to the more commonly estimated respiratory rate, on a daily basis.

  16. Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera

    PubMed Central

    Reyes, Bersain A.; Reljin, Natasa; Kong, Youngsun; Nam, Yunyoung; Ha, Sangho; Chon, Ki H.

    2016-01-01

    A smartphone-based tidal volume (VT) estimator was recently introduced by our research group, where an Android application provides a chest movement signal whose peak-to-peak amplitude is highly correlated with reference VT measured by a spirometer. We found a Normalized Root Mean Squared Error (NRMSE) of 14.998% ± 5.171% (mean ± SD) when the smartphone measures were calibrated using spirometer data. However, the availability of a spirometer device for calibration is not realistic outside clinical or research environments. In order to be used by the general population on a daily basis, a simple calibration procedure not relying on specialized devices is required. In this study, we propose taking advantage of the linear correlation between smartphone measurements and VT to obtain a calibration model using information computed while the subject breathes through a commercially-available incentive spirometer (IS). Experiments were performed on twelve (N = 12) healthy subjects. In addition to corroborating findings from our previous study using a spirometer for calibration, we found that the calibration procedure using an IS resulted in a fixed bias of −0.051 L and a RMSE of 0.189 ± 0.074 L corresponding to 18.559% ± 6.579% when normalized. Although it has a small underestimation and slightly increased error, the proposed calibration procedure using an IS has the advantages of being simple, fast, and affordable. This study supports the feasibility of developing a portable smartphone-based breathing status monitor that provides information about breathing depth, in addition to the more commonly estimated respiratory rate, on a daily basis. PMID:26999152

  17. An experimental protocol for the definition of upper limb anatomical frames on children using magneto-inertial sensors.

    PubMed

    Ricci, L; Formica, D; Tamilia, E; Taffoni, F; Sparaci, L; Capirci, O; Guglielmelli, E

    2013-01-01

    Motion capture based on magneto-inertial sensors is a technology enabling data collection in unstructured environments, allowing "out of the lab" motion analysis. This technology is a good candidate for motion analysis of children thanks to the reduced weight and size as well as the use of wireless communication that has improved its wearability and reduced its obtrusivity. A key issue in the application of such technology for motion analysis is its calibration, i.e. a process that allows mapping orientation information from each sensor to a physiological reference frame. To date, even if there are several calibration procedures available for adults, no specific calibration procedures have been developed for children. This work addresses this specific issue presenting a calibration procedure for motion capture of thorax and upper limbs on healthy children. Reported results suggest comparable performance with similar studies on adults and emphasize some critical issues, opening the way to further improvements.

  18. Multiple calibrator measurements improve accuracy and stability estimates of automated assays.

    PubMed

    Akbas, Neval; Budd, Jeffrey R; Klee, George G

    2016-01-01

    The effects of combining multiple calibrations on assay accuracy (bias) and measurement of calibration stability were investigated for total triiodothyronine (TT3), vitamin B12 and luteinizing hormone (LH) using Beckman Coulter's Access 2 analyzer. Three calibration procedures (CC1, CC2 and CC3) combined 12, 34 and 56 calibrator measurements over 1, 2, and 3 days. Bias was calculated between target values and average measured value over 3 consecutive days after calibration. Using regression analysis of calibrator measurements versus measurement date, calibration stability was determined as the maximum number of days before a calibrator measurement exceeded 5% tolerance limits. Competitive assays (TT3, vitamin B12) had positive time regression slopes, while sandwich assay (LH) had a negative slope. Bias values for TT3 were -2.49%, 1.49%, and -0.50% using CC1, CC2 and CC3 respectively, with calibrator stability of 32, 20, and 30 days. Bias values for vitamin B12 were 2.44%, 0.91%, and -0.50%, with calibrator stability of 4, 9, and 12 days. Bias values for LH were 2.26%, 1.44% and -0.29% with calibrator stability of >43, 39 and 36 days. Measured stability was more consistent across calibration procedures using percent change rather than difference from target: 26 days for TT3, 12 days for B12 and 31 days for LH. Averaging over multiple calibrations produced smaller bias, consistent with improved accuracy. Time regression slopes in percent change were unaffected by number of calibration measurements but calibrator stability measured from the target value was highly affected by the calibrator value at time zero.

  19. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Torque transducer verification and...

  20. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Torque transducer verification and...

  1. Online C-arm calibration using a marked guide wire for 3D reconstruction of pulmonary arteries

    NASA Astrophysics Data System (ADS)

    Vachon, Étienne; Miró, Joaquim; Duong, Luc

    2017-03-01

    3D reconstruction of vessels from 2D X-ray angiography is highly relevant to improve the visualization and the assessment of vascular structures such as pulmonary arteries by interventional cardiologists. However, to ensure a robust and accurate reconstruction, C-arm gantry parameters must be properly calibrated to provide clinically acceptable results. Calibration procedures often rely on calibration objects and complex protocol which is not adapted to an intervention context. In this study, a novel calibration algorithm for C-arm gantry is presented using the instrumentation such as catheters and guide wire. This ensures the availability of a minimum set of correspondences and implies minimal changes to the clinical workflow. The method was evaluated on simulated data and on retrospective patient datasets. Experimental results on simulated datasets demonstrate a calibration that allows a 3D reconstruction of the guide wire up to a geometric transformation. Experiments with patients datasets show a significant decrease of the retro projection error to 0.17 mm 2D RMS. Consequently, such procedure might contribute to identify any calibration drift during the intervention.

  2. Gaussian process based modeling and experimental design for sensor calibration in drifting environments

    PubMed Central

    Geng, Zongyu; Yang, Feng; Chen, Xi; Wu, Nianqiang

    2016-01-01

    It remains a challenge to accurately calibrate a sensor subject to environmental drift. The calibration task for such a sensor is to quantify the relationship between the sensor’s response and its exposure condition, which is specified by not only the analyte concentration but also the environmental factors such as temperature and humidity. This work developed a Gaussian Process (GP)-based procedure for the efficient calibration of sensors in drifting environments. Adopted as the calibration model, GP is not only able to capture the possibly nonlinear relationship between the sensor responses and the various exposure-condition factors, but also able to provide valid statistical inference for uncertainty quantification of the target estimates (e.g., the estimated analyte concentration of an unknown environment). Built on GP’s inference ability, an experimental design method was developed to achieve efficient sampling of calibration data in a batch sequential manner. The resulting calibration procedure, which integrates the GP-based modeling and experimental design, was applied on a simulated chemiresistor sensor to demonstrate its effectiveness and its efficiency over the traditional method. PMID:26924894

  3. Assessment and certification of neonatal incubator sensors through an inferential neural network.

    PubMed

    de Araújo, José Medeiros; de Menezes, José Maria Pires; Moura de Albuquerque, Alberto Alexandre; da Mota Almeida, Otacílio; Ugulino de Araújo, Fábio Meneghetti

    2013-11-15

    Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal.

  4. Assessment and Certification of Neonatal Incubator Sensors through an Inferential Neural Network

    PubMed Central

    de Araújo Júnior, José Medeiros; de Menezes Júnior, José Maria Pires; de Albuquerque, Alberto Alexandre Moura; Almeida, Otacílio da Mota; de Araújo, Fábio Meneghetti Ugulino

    2013-01-01

    Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal. PMID:24248278

  5. Jeff Cheatham, senior metrologist

    NASA Image and Video Library

    2015-01-27

    JEFF CHEATHAM, SENIOR METROLOGIST AT THE MARSHALL METROLOGY AND CALIBRATION LABORATORY, SPENT 12 YEARS DEVELOPING 2400 AUTOMATED SOFTWARE PROCEDURES USED FOR CALIBRATION AND TESTING SPACE VEHICLES AND EQUIPMENT

  6. Ability Estimation and Item Calibration Using the One and Three Parameter Logistic Models: A Comparative Study. Research Report 77-1.

    ERIC Educational Resources Information Center

    Reckase, Mark D.

    Latent trait model calibration procedures were used on data obtained from a group testing program. The one-parameter model of Wright and Panchapakesan and the three-parameter logistic model of Wingersky, Wood, and Lord were selected for comparison. These models and their corresponding estimation procedures were compared, using actual and simulated…

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF CALIBRATION AND SURROGATE RECOVERY SOLUTIONS FOR GC/MS ANALYSIS OF PESTICIDES (BCO-L-21.1)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for preparing calibration curve solutions used for gas chromatography/mass spectrometry (GC/MS) analysis of chlorpyrifos, diazinon, malathion, DDT, DDE, DDD, a-chlordane, and g-chlordane in dust, soil, air, and handwipe sample ext...

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF THE PERKIN-ELMER ZEEMAN/5000 SYSTEM ATOMIC ABSORPTION SPECTROMETER (BCO-L-6.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the start-up, calibration, operation, and maintenance procedures for the Perkin-Elmer 5000 atomic absorption spectrophotometer (PE 5000 AA), and the Perkin Elmer 5000 Zeeman graphite furnace atomic absorption spectrophotometer (PE 5000Z GFAA)...

  9. Improving Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2012-02-01

    New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market. Reducing the energy use of existing homes in the United States offers significant energy-saving opportunities, which can be identified through building simulation software tools that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis for residential buildings, the National Renewable Energy Laboratory's (NREL) Buildings Research team developed the Building Energy Simulation Test for Existing Homes (BESTEST-EX), a method for diagnosing and correcting errors in building energy audit software and calibration procedures. BESTEST-EX consists of building physics and utility billmore » calibration test cases, which software developers can use to compare their tools simulation findings to reference results generated with state-of-the-art simulation tools. Overall, the BESTEST-EX methodology: (1) Tests software predictions of retrofit energy savings in existing homes; (2) Ensures building physics calculations and utility bill calibration procedures perform to a minimum standard; and (3) Quantifies impacts of uncertainties in input audit data and occupant behavior. BESTEST-EX is helping software developers identify and correct bugs in their software, as well as develop and test utility bill calibration procedures.« less

  10. Metafitting: Weight optimization for least-squares fitting of PTTI data

    NASA Technical Reports Server (NTRS)

    Douglas, Rob J.; Boulanger, J.-S.

    1995-01-01

    For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

  11. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    PubMed Central

    Kashani, Alireza G.; Olsen, Michael J.; Parrish, Christopher E.; Wilson, Nicholas

    2015-01-01

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration. PMID:26561813

  12. Reprocessing VIIRS sensor data records from the early SNPP mission

    NASA Astrophysics Data System (ADS)

    Blonski, Slawomir; Cao, Changyong

    2016-10-01

    The Visible-Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite began acquiring Earth observations in November 2011. VIIRS data from all spectral bands became available three months after launch when all infrared-band detectors were cooled down to operational temperature. Before that, VIIRS sensor data record (SDR) products were successfully generated for the visible and near infrared (VNIR) bands. Although VIIRS calibration has been significantly improved through the four years of the SNPP mission, SDR reprocessing for this early mission phase has yet to be performed. Despite a rapid decrease in the telescope throughput that occurred during the first few months on orbit, calibration coefficients for the VNIR bands were recently successfully generated using an automated procedure that is currently deployed in the operational SDR production system. The reanalyzed coefficients were derived from measurements collected during solar calibration events that occur on every SNPP orbit since the beginning of the mission. The new coefficients can be further used to reprocess the VIIRS SDR products. In this study, they are applied to reprocess VIIRS data acquired over pseudo-invariant calibration sites Libya 4 and Sudan 1 in Sahara between November 2011 and February 2012. Comparison of the reprocessed SDR products with the original ones demonstrates improvements in the VIIRS calibration provided by the reprocessing. Since SNPP is the first satellite in a series that will form the Joint Polar Satellite System (JPSS), calibration methods developed for the SNPP VIIRS will also apply to the future JPSS measurements.

  13. Data Quality Assurance and Control for AmeriFlux Network at CDIAC, ORNL

    NASA Astrophysics Data System (ADS)

    Shem, W.; Boden, T.; Krassovski, M.; Yang, B.

    2014-12-01

    The Carbon Dioxide Information Analysis Center (CDIAC) at the Oak Ridge National Laboratory (ORNL) serves as the long-term data repository for the AmeriFlux network. Datasets currently available include hourly or half-hourly meteorological and flux observations, biological measurement records, and synthesis data products. Currently there is a lack of standardized nomenclature and specifically designed procedures for data quality assurance/control in processing and handling micrometeorological and ecological data at individual flux sites. CDIAC's has bridged this gap by providing efficient and accurate procedures for data quality control and standardization of the results for easier assimilation by the models used in climate science. In this presentation we highlight the procedures we have put in place to scrutinize continuous flux and meteorological data within Ameriflux network. We itemize some basic data quality issues that we have observed over the past years and include some examples of typical data quality issues. Such issues, e.g., incorrect time-stamping, poor calibration or maintenance of instruments, missing or incomplete metadata and others that are commonly over-looked by PI's, invariably impact the time-series observations.

  14. Calibration of ground-based microwave radiometers - Accuracy assessment and recommendations for network users

    NASA Astrophysics Data System (ADS)

    Pospichal, Bernhard; Küchler, Nils; Löhnert, Ulrich; Crewell, Susanne; Czekala, Harald; Güldner, Jürgen

    2016-04-01

    Ground-based microwave radiometers (MWR) are becoming widely used in atmospheric remote sensing and start to be routinely operated by national weather services and other institutions. However, common standards for calibration of these radiometers and a detailed knowledge about the error characteristics is needed, in order to assimilate the data into models. Intercomparisons of calibrations by different MWRs have rarely been done. Therefore, two calibration experiments in Lindenberg (2014) and Meckenheim (2015) were performed in the frame of TOPROF (Cost action ES1303) in order to assess uncertainties and differences between various instruments. In addition, a series of experiments were taken in Oklahoma in autumn 2014. The focus lay on the performance of the two main instrument types, which are currently used operationally. These are the MP-Profiler series by Radiometrics Corporation as well as the HATPRO series by Radiometer Physics GmbH (RPG). Both instrument types are operating in two frequency bands, one along the 22 GHz water vapour line, the other one at the lower wing of the 60 GHz oxygen absorption complex. The goal was to establish protocols for providing quality controlled (QC) MWR data and their uncertainties. To this end, standardized calibration procedures for MWR were developed and recommendations for radiometer users were compiled. We focus here mainly on data types, integration times and optimal settings for calibration intervals, both for absolute (liquid nitrogen, tipping curve) as well as relative (hot load, noise diode) calibrations. Besides the recommendations for ground-based MWR operators, we will present methods to determine the accuracy of the calibration as well as means for automatic data quality control. In addition, some results from the intercomparison of different radiometers will be discussed.

  15. Development of dynamic calibration methods for POGO pressure transducers. [for space shuttle

    NASA Technical Reports Server (NTRS)

    Hilten, J. S.; Lederer, P. S.; Vezzetti, C. F.; Mayo-Wells, J. F.

    1976-01-01

    Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

  16. BESTEST-EX | Buildings | NREL

    Science.gov Websites

    method for testing home energy audit software and associated calibration methods. BESTEST-EX is one of Energy Analysis Model Calibration Methods. When completed, the ANSI/RESNET SMOT will specify test procedures for evaluating calibration methods used in conjunction with predicting building energy use and

  17. 30 CFR 90.203 - Certified person; maintenance and calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.203 Certified person; maintenance and calibration. (a) Approved sampling devices shall be maintained and calibrated by a certified person. (b) To be certified, a...

  18. Procedure for calibrating the Technicon Colorimeter I.

    PubMed

    Black, J C; Furman, W B

    1975-05-01

    We describe a rapid method for calibrating the Technicon AutoAnalyzer colorimeter I. Test solutions of bromphenol blue are recommended for the calibration, in preference to solutions of potassium dichromate, based on considerations of the instrument's working range and of the stray light characteristics of the associated filters.

  19. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... accuracy of the test system throughout the laboratory's reportable range of test results for the test system. Unless otherwise specified in this subpart, for each applicable test system the laboratory must... test system instructions, using calibration materials provided or specified, and with at least the...

  20. CATE 2016 Indonesia: Image Calibration, Intensity Calibration, and Drift Scan

    NASA Astrophysics Data System (ADS)

    Hare, H. S.; Kovac, S. A.; Jensen, L.; McKay, M. A.; Bosh, R.; Watson, Z.; Mitchell, A. M.; Penn, M. J.

    2016-12-01

    The citizen Continental America Telescopic Eclipse (CATE) experiment aims to provide equipment for 60 sites across the path of totality for the United States August 21st, 2017 total solar eclipse. The opportunity to gather ninety minutes of continuous images of the solar corona is unmatched by any other previous eclipse event. In March of 2016, 5 teams were sent to Indonesia to test CATE equipment and procedures on the March 9th, 2016 total solar eclipse. Also, a goal of the trip was practice and gathering data to use in testing data reduction methods. Of the five teams, four collected data. While in Indonesia, each group participated in community outreach in the location of their site. The 2016 eclipse allowed CATE to test the calibration techniques for the 2017 eclipse. Calibration dark current and flat field images were collected to remove variation across the cameras. Drift scan observations provided information to rotationally align the images from each site. These image's intensity values allowed for intensity calibration for each of the sites. A GPS at each site corrected for major computer errors in time measurement of images. Further refinement of these processes is required before the 2017 eclipse. This work was made possible through the NSO Training for the 2017 Citizen CATE Experiment funded by NASA (NASA NNX16AB92A).

  1. Input variable selection and calibration data selection for storm water quality regression models.

    PubMed

    Sun, Siao; Bertrand-Krajewski, Jean-Luc

    2013-01-01

    Storm water quality models are useful tools in storm water management. Interest has been growing in analyzing existing data for developing models for urban storm water quality evaluations. It is important to select appropriate model inputs when many candidate explanatory variables are available. Model calibration and verification are essential steps in any storm water quality modeling. This study investigates input variable selection and calibration data selection in storm water quality regression models. The two selection problems are mutually interacted. A procedure is developed in order to fulfil the two selection tasks in order. The procedure firstly selects model input variables using a cross validation method. An appropriate number of variables are identified as model inputs to ensure that a model is neither overfitted nor underfitted. Based on the model input selection results, calibration data selection is studied. Uncertainty of model performances due to calibration data selection is investigated with a random selection method. An approach using the cluster method is applied in order to enhance model calibration practice based on the principle of selecting representative data for calibration. The comparison between results from the cluster selection method and random selection shows that the former can significantly improve performances of calibrated models. It is found that the information content in calibration data is important in addition to the size of calibration data.

  2. Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fat’yanov, O. V., E-mail: fatyan1@gps.caltech.edu; Asimow, P. D., E-mail: asimow@gps.caltech.edu

    2015-10-15

    We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documentedmore » methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.« less

  3. On-Demand Calibration and Evaluation for Electromagnetically Tracked Laparoscope in Augmented Reality Visualization

    PubMed Central

    Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2017-01-01

    Purpose Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that calibration can be performed in the OR on demand. Methods We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration result in the OR, we integrated a tube phantom with fCalib and overlaid a virtual representation of the tube on the live video scene. Results We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggested that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, would affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s – 22.7 s). Conclusions We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand. PMID:27250853

  4. On-demand calibration and evaluation for electromagnetically tracked laparoscope in augmented reality visualization.

    PubMed

    Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2016-06-01

    Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that the calibration can be performed in the OR on demand. We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration results in the OR, we integrated a tube phantom with fCalib prototype and overlaid a virtual representation of the tube on the live video scene. We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggest that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, might affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s-22.7 s). We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand.

  5. 40 CFR 86.1422 - Analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Trucks; Certification Short Test Procedures § 86.1422 Analyzer calibration. (a) Determine that the... check. Prior to its introduction into service and at specified periods thereafter, the analyzer must...

  6. 40 CFR 86.1323-2007 - Oxides of nitrogen analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Oxides of nitrogen analyzer... Exhaust Test Procedures § 86.1323-2007 Oxides of nitrogen analyzer calibration. This section describes the initial and periodic calibration of the chemiluminescent oxides of nitrogen analyzer. (a) Prior to...

  7. 40 CFR 86.1323-2007 - Oxides of nitrogen analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Oxides of nitrogen analyzer... Exhaust Test Procedures § 86.1323-2007 Oxides of nitrogen analyzer calibration. This section describes the initial and periodic calibration of the chemiluminescent oxides of nitrogen analyzer. (a) Prior to...

  8. 40 CFR 86.1323-2007 - Oxides of nitrogen analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Oxides of nitrogen analyzer... Exhaust Test Procedures § 86.1323-2007 Oxides of nitrogen analyzer calibration. This section describes the initial and periodic calibration of the chemiluminescent oxides of nitrogen analyzer. (a) Prior to...

  9. 40 CFR 86.1323-2007 - Oxides of nitrogen analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Oxides of nitrogen analyzer... Exhaust Test Procedures § 86.1323-2007 Oxides of nitrogen analyzer calibration. This section describes the initial and periodic calibration of the chemiluminescent oxides of nitrogen analyzer. (a) Prior to...

  10. 40 CFR 86.524-78 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Carbon dioxide analyzer calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.524-78 Carbon dioxide analyzer calibration. (a) Prior to its introduction into service and monthly thereafter the NDIR carbon dioxide...

  11. 40 CFR 86.1416 - Calibration; frequency and overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Emission Regulations for New Gasoline-Fueled Otto-Cycle Light-Duty Vehicles and New Gasoline-Fueled Otto-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1416 Calibration; frequency and... calibration of the analyzer must be checked. The analyzer must be adjusted or repaired as necessary. (c) Water...

  12. 40 CFR 86.1416 - Calibration; frequency and overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Emission Regulations for New Gasoline-Fueled Otto-Cycle Light-Duty Vehicles and New Gasoline-Fueled Otto-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1416 Calibration; frequency and... calibration of the analyzer must be checked. The analyzer must be adjusted or repaired as necessary. (c) Water...

  13. 40 CFR 86.1416 - Calibration; frequency and overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Emission Regulations for New Gasoline-Fueled Otto-Cycle Light-Duty Vehicles and New Gasoline-Fueled Otto-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1416 Calibration; frequency and... calibration of the analyzer must be checked. The analyzer must be adjusted or repaired as necessary. (c) Water...

  14. 40 CFR 86.1416 - Calibration; frequency and overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Emission Regulations for New Gasoline-Fueled Otto-Cycle Light-Duty Vehicles and New Gasoline-Fueled Otto-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1416 Calibration; frequency and... calibration of the analyzer must be checked. The analyzer must be adjusted or repaired as necessary. (c) Water...

  15. 40 CFR 86.124-78 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon dioxide analyzer calibration... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... Complete Heavy-Duty Vehicles; Test Procedures § 86.124-78 Carbon dioxide analyzer calibration. Prior to its...

  16. 40 CFR 90.315 - Analyzer initial calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... specifications in § 90.316(b). (c) Zero setting and calibration. Using purified synthetic air (or nitrogen), set the CO, CO2, NOX. and HC analyzers at zero. Connect the appropriate calibrating gases to the analyzers...) Rechecking of zero setting. Recheck the zero setting and, if necessary, repeat the procedure described in...

  17. 40 CFR 90.315 - Analyzer initial calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... specifications in § 90.316(b). (c) Zero setting and calibration. Using purified synthetic air (or nitrogen), set the CO, CO2, NOX. and HC analyzers at zero. Connect the appropriate calibrating gases to the analyzers...) Rechecking of zero setting. Recheck the zero setting and, if necessary, repeat the procedure described in...

  18. 40 CFR 90.315 - Analyzer initial calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... specifications in § 90.316(b). (c) Zero setting and calibration. Using purified synthetic air (or nitrogen), set the CO, CO2, NOX. and HC analyzers at zero. Connect the appropriate calibrating gases to the analyzers...) Rechecking of zero setting. Recheck the zero setting and, if necessary, repeat the procedure described in...

  19. 40 CFR 90.315 - Analyzer initial calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specifications in § 90.316(b). (c) Zero setting and calibration. Using purified synthetic air (or nitrogen), set the CO, CO2, NOX. and HC analyzers at zero. Connect the appropriate calibrating gases to the analyzers...) Rechecking of zero setting. Recheck the zero setting and, if necessary, repeat the procedure described in...

  20. 40 CFR 90.315 - Analyzer initial calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specifications in § 90.316(b). (c) Zero setting and calibration. Using purified synthetic air (or nitrogen), set the CO, CO2, NOX. and HC analyzers at zero. Connect the appropriate calibrating gases to the analyzers...) Rechecking of zero setting. Recheck the zero setting and, if necessary, repeat the procedure described in...

  1. Photogrammetric camera calibration

    USGS Publications Warehouse

    Tayman, W.P.; Ziemann, H.

    1984-01-01

    Section 2 (Calibration) of the document "Recommended Procedures for Calibrating Photogrammetric Cameras and Related Optical Tests" from the International Archives of Photogrammetry, Vol. XIII, Part 4, is reviewed in the light of recent practical work, and suggestions for changes are made. These suggestions are intended as a basis for a further discussion. ?? 1984.

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION, AND MAINTENANCE OF THE PERKIN-ELMER ZEEMAN/5000 SYSTEM ATOMIC ABSORPTION SPECTROPHOTOMETER (BCO-L-6.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the start-up, calibration, operation, and maintenance procedures for the Perkin-Elmer 5000 atomic absorption spectrophotometer (PE 5000 AA), and the Perkin Elmer 5000 Zeeman graphite furnace atomic absorption spectrophotometer (PE 5000Z GFAA)...

  3. Performance of ground attitude determination procedures for HEAO-1

    NASA Technical Reports Server (NTRS)

    Fallon, L., III; Sturch, C. R.

    1978-01-01

    Ground attitude support for HEAO 1 provided at GSFC by the HEAO 1 Attitude Ground Support System (AGSS) is described. Information telemetered from Sun sensors, gyroscopes, star trackers, and an onboard computer are used by the AGSS to compute updates to the onboard attitude reference and gyro calibration parameters. The onboard computer utilizes these updates in providing continuous attitudes (accurate to 0.25degree) for use in the observatory's attitude control procedures. The relationship between HEAO 1 onboard and ground processing, the procedures used by the AGSS in computing attitude and gyro calibration updates, and the performance of these procedures in the HEAO 1 postlaunch environment is discussed.

  4. Calibration method for a large-scale structured light measurement system.

    PubMed

    Wang, Peng; Wang, Jianmei; Xu, Jing; Guan, Yong; Zhang, Guanglie; Chen, Ken

    2017-05-10

    The structured light method is an effective non-contact measurement approach. The calibration greatly affects the measurement precision of structured light systems. To construct a large-scale structured light system with high accuracy, a large-scale and precise calibration gauge is always required, which leads to an increased cost. To this end, in this paper, a calibration method with a planar mirror is proposed to reduce the calibration gauge size and cost. An out-of-focus camera calibration method is also proposed to overcome the defocusing problem caused by the shortened distance during the calibration procedure. The experimental results verify the accuracy of the proposed calibration method.

  5. Performance of CMOS imager as sensing element for a Real-time Active Pixel Dosimeter for Interventional Radiology procedures

    NASA Astrophysics Data System (ADS)

    Magalotti, D.; Bissi, L.; Conti, E.; Paolucci, M.; Placidi, P.; Scorzoni, A.; Servoli, L.

    2014-01-01

    Staff members applying Interventional Radiology procedures are exposed to ionizing radiation, which can induce detrimental effects to the human body, and requires an improvement of radiation protection. This paper is focused on the study of the sensor element for a wireless real-time dosimeter to be worn by the medical staff during the interventional radiology procedures, in the framework of the Real-Time Active PIxel Dosimetry (RAPID) INFN project. We characterize a CMOS imager to be used as detection element for the photons scattered by the patient body. The CMOS imager has been first characterized in laboratory using fluorescence X-ray sources, then a PMMA phantom has been used to diffuse the X-ray photons from an angiography system. Different operating conditions have been used to test the detector response in realistic situations, by varying the X-ray tube parameters (continuous/pulsed mode, tube voltage and current, pulse parameters), the sensor parameters (gain, integration time) and the relative distance between sensor and phantom. The sensor response has been compared with measurements performed using passive dosimeters (TLD) and also with a certified beam, in an accredited calibration centre, in order to obtain an absolute calibration. The results are very encouraging, with dose and dose rate measurement uncertainties below the 10% level even for the most demanding Interventional Radiology protocols.

  6. 40 CFR 1065.330 - Exhaust-flow calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Flow-Related Measurements § 1065.330... use other reference meters such as laminar flow elements, which are not commonly designed to withstand...

  7. Experimental techniques for the calibration of lidar depolarization channels in EARLINET

    NASA Astrophysics Data System (ADS)

    Belegante, Livio; Bravo-Aranda, Juan Antonio; Freudenthaler, Volker; Nicolae, Doina; Nemuc, Anca; Ene, Dragos; Alados-Arboledas, Lucas; Amodeo, Aldo; Pappalardo, Gelsomina; D'Amico, Giuseppe; Amato, Francesco; Engelmann, Ronny; Baars, Holger; Wandinger, Ulla; Papayannis, Alexandros; Kokkalis, Panos; Pereira, Sérgio N.

    2018-02-01

    Particle depolarization ratio retrieved from lidar measurements are commonly used for aerosol-typing studies, microphysical inversion, or mass concentration retrievals. The particle depolarization ratio is one of the primary parameters that can differentiate several major aerosol components but only if the measurements are accurate enough. The accuracy related to the retrieval of particle depolarization ratios is the driving factor for assessing and improving the uncertainties of the depolarization products. This paper presents different depolarization calibration procedures used to improve the quality of the depolarization data. The results illustrate a significant improvement of the depolarization lidar products for all the selected lidar stations that have implemented depolarization calibration procedures. The calibrated volume and particle depolarization profiles at 532 nm show values that fall within a range that is generally accepted in the literature.

  8. Node-to-node field calibration of wireless distributed air pollution sensor network.

    PubMed

    Kizel, Fadi; Etzion, Yael; Shafran-Nathan, Rakefet; Levy, Ilan; Fishbain, Barak; Bartonova, Alena; Broday, David M

    2018-02-01

    Low-cost air quality sensors offer high-resolution spatiotemporal measurements that can be used for air resources management and exposure estimation. Yet, such sensors require frequent calibration to provide reliable data, since even after a laboratory calibration they might not report correct values when they are deployed in the field, due to interference with other pollutants, as a result of sensitivity to environmental conditions and due to sensor aging and drift. Field calibration has been suggested as a means for overcoming these limitations, with the common strategy involving periodical collocations of the sensors at an air quality monitoring station. However, the cost and complexity involved in relocating numerous sensor nodes back and forth, and the loss of data during the repeated calibration periods make this strategy inefficient. This work examines an alternative approach, a node-to-node (N2N) calibration, where only one sensor in each chain is directly calibrated against the reference measurements and the rest of the sensors are calibrated sequentially one against the other while they are deployed and collocated in pairs. The calibration can be performed multiple times as a routine procedure. This procedure minimizes the total number of sensor relocations, and enables calibration while simultaneously collecting data at the deployment sites. We studied N2N chain calibration and the propagation of the calibration error analytically, computationally and experimentally. The in-situ N2N calibration is shown to be generic and applicable for different pollutants, sensing technologies, sensor platforms, chain lengths, and sensor order within the chain. In particular, we show that chain calibration of three nodes, each calibrated for a week, propagate calibration errors that are similar to those found in direct field calibration. Hence, N2N calibration is shown to be suitable for calibration of distributed sensor networks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A procedure for radiometric recalibration of Landsat 5 TM reflective-band data

    USGS Publications Warehouse

    Chander, G.; Haque, M.O.; Micijevic, E.; Barsi, J.A.

    2010-01-01

    From the Landsat program's inception in 1972 to the present, the Earth science user community has been benefiting from a historical record of remotely sensed data. The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone for this extensive archive. Historically, the radiometric calibration procedure for the L5 TM imagery used the detectors' response to the internal calibrator (IC) on a scene-by-scene basis to determine the gain and offset for each detector. The IC system degraded with time, causing radiometric calibration errors up to 20%. In May 2003, the L5 TM data processed and distributed by the U.S. Geological Survey (USGS) Earth Resources Observation and Science Center through the National Landsat Archive Production System (NLAPS) were updated to use a lifetime lookup-table (LUT) gain model to radiometrically calibrate TM data instead of using scene-specific IC gains. Further modification of the gain model was performed in 2007. The L5 TM data processed using IC prior to the calibration update do not benefit from the recent calibration revisions. A procedure has been developed to give users the ability to recalibrate their existing level-1 products. The best recalibration results are obtained if the work-order report that was included in the original standard data product delivery is available. However, if users do not have the original work-order report, the IC trends can be used for recalibration. The IC trends were generated using the radiometric gain trends recorded in the NLAPS database. This paper provides the details of the recalibration procedure for the following: 1) data processed using IC where users have the work-order file; 2) data processed using IC where users do not have the work-order file; 3) data processed using prelaunch calibration parameters; and 4) data processed using the previous version of the LUT (e.g., LUT03) that was released before April 2, 2007.

  10. Methods and apparatus for measurement of the resistivity of geological formations from within cased boreholes

    DOEpatents

    Vail, W.B. III.

    1989-04-11

    Methods and apparatus are disclosed which allow measurement of the resistivity of a geological formation through borehole casing which may be surrounded by brine saturated cement. A.C. current is passed from an electrode in electrical contact with the interior of the borehole casing to an electrode on the surface of the earth. The A.C. voltage difference is measured between two additional vertically disposed electrodes on the interior of the casing which provides a measure of the resistivity of the geological formation. A calibration and nulling procedure is presented which minimizes the influence of variations in the thickness of the casing. The procedure also minimizes the influence of inaccurate placements of the additional vertically disposed electrodes. 3 figs.

  11. Methods and apparatus for measurement of the resistivity of geological formations from within cased boreholes

    DOEpatents

    Vail, III, William B.

    1989-01-01

    Methods and apparatus are disclosed which allow measurement of the resistivity of a geological formation through borehole casing which may be surrounded by brine saturated cement. A.C. current is passed from an electrode in electrical contact with the interior of the borehole casing to an electrode on the surface of the earth. The A.C. voltage difference is measured between two additional vertically disposed electrodes on the interior of the casing which provides a measure of the resistivity of the geological formation. A calibration and nulling procedure is presented which minimizes the influence of variations in the thickness of the casing. The procedure also minimizes the influence of inaccurate placements of the additional vertically disposed electrodes.

  12. A versatile calibration procedure for portable coded aperture gamma cameras and RGB-D sensors

    NASA Astrophysics Data System (ADS)

    Paradiso, V.; Crivellaro, A.; Amgarou, K.; de Lanaute, N. Blanc; Fua, P.; Liénard, E.

    2018-04-01

    The present paper proposes a versatile procedure for the geometrical calibration of coded aperture gamma cameras and RGB-D depth sensors, using only one radioactive point source and a simple experimental set-up. Calibration data is then used for accurately aligning radiation images retrieved by means of the γ-camera with the respective depth images computed with the RGB-D sensor. The system resulting from such a combination is thus able to retrieve, automatically, the distance of radioactive hotspots by means of pixel-wise mapping between gamma and depth images. This procedure is of great interest for a wide number of applications, ranging from precise automatic estimation of the shape and distance of radioactive objects to Augmented Reality systems. Incidentally, the corresponding results validated the choice of a perspective design model for a coded aperture γ-camera.

  13. Preliminary Evaluation of the Radiometric Calibration of LANDSAT-4 Thematic Mapper Data by the Canada Centre for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Murphy, J.; Park, W.; Fitzgerald, A.

    1985-01-01

    The radiometric characteristics of the LANDSAT-4 TM sensor are being studied with a view to developing absolute and relative radiometric calibration procedures. Preliminary results from several different approaches to the relative correction of all detectors within each band are reported. Topics covered include: the radiometric correction method; absolute calibration; the relative radiometric calibration algorithm; relative gain and offset calibration; relative gain and offset observations; and residual radiometric stripping.

  14. Automatic Calibration of Global Flow Routing Model Parameters in the Amazon Basin Using Virtual SWOT Data

    NASA Astrophysics Data System (ADS)

    Mouffe, Melodie; Getirana, Augusto; Ricci, Sophie; Lion, Christine; Biancamaria, Sylvian; Boone, Aaron; Mognard, Nelly; Rogel, Philippe

    2013-09-01

    The Surface Water and Ocean Topography (SWOT) wide swath altimetry mission will provide measurements of water surface elevations (WSE) at a global scale. The aim of this study is to investigate the potential of these satellite data for the calibration of the hydrological model HyMAP, over the Amazon river basin. Since SWOT has not yet been launched, synthetical observations are used to calibrate the river bed depth and width, the Manning coefficient and the baseflow concentration time. The calibration process stands in the minimization of a cost function using an evolutionnary, global and multi-objective algorithm that describes the difference between the simulated and the observed WSE. We found that the calibration procedure is able to retrieve an optimal set of parameters such that it brings the simulated WSE closer to the observation. Still with a global calibration procedure where a uniform correction is applied, the improvement is limited to a mean correction over the catchment and the simulation period. We conclude that in order to benefit from the high resolution and complete coverage of the SWOT mission, the calibration process should be achieved sequentially in time over sub-domains as observations become available.

  15. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  16. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  17. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  18. NASA-6 atmospheric measuring station. [calibration, functional checks, and operation of measuring instruments

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Information required to calibrate, functionally check, and operate the Instrumentation Branch equipment on the NASA-6 aircraft is provided. All procedures required for preflight checks and in-flight operation of the NASA-6 atmospheric measuring station are given. The calibration section is intended for only that portion of the system maintained and calibrated by IN-MSD-12 Systems Operation contractor personnel. Maintenance is not included.

  19. Flush Airdata Sensing (FADS) System Calibration Procedures and Results for Blunt Forebodies

    NASA Technical Reports Server (NTRS)

    Cobleigh, Brent R.; Whitmore, Stephen A.; Haering, Edward A., Jr.; Borrer, Jerry; Roback, V. Eric

    1999-01-01

    Blunt-forebody pressure data are used to study the behavior of the NASA Dryden Flight Research Center flush airdata sensing (FADS) pressure model and solution algorithm. The model relates surface pressure measurements to the airdata state. Spliced from the potential flow solution for uniform flow over a sphere and the modified Newtonian impact theory, the model was shown to apply to a wide range of blunt-forebody shapes and Mach numbers. Calibrations of a sphere, spherical cones, a Rankine half body, and the F-14, F/A-18, X-33, X-34, and X-38 configurations are shown. The three calibration parameters are well-behaved from Mach 0.25 to Mach 5.0, an angle-of-attack range extending to greater than 30 deg, and an angle-of-sideslip range extending to greater than 15 deg. Contrary to the sharp calibration changes found on traditional pitot-static systems at transonic speeds, the FADS calibrations are smooth, monotonic functions of Mach number and effective angles of attack and sideslip. Because the FADS calibration is sensitive to pressure port location, detailed measurements of the actual pressure port locations on the flight vehicle are required and the wind-tunnel calibration model should have pressure ports in similar locations. The procedure for calibrating a FADS system is outlined.

  20. User-friendly freehand ultrasound calibration using Lego bricks and automatic registration.

    PubMed

    Xiao, Yiming; Yan, Charles Xiao Bo; Drouin, Simon; De Nigris, Dante; Kochanowska, Anna; Collins, D Louis

    2016-09-01

    As an inexpensive, noninvasive, and portable clinical imaging modality, ultrasound (US) has been widely employed in many interventional procedures for monitoring potential tissue deformation, surgical tool placement, and locating surgical targets. The application requires the spatial mapping between 2D US images and 3D coordinates of the patient. Although positions of the devices (i.e., ultrasound transducer) and the patient can be easily recorded by a motion tracking system, the spatial relationship between the US image and the tracker attached to the US transducer needs to be estimated through an US calibration procedure. Previously, various calibration techniques have been proposed, where a spatial transformation is computed to match the coordinates of corresponding features in a physical phantom and those seen in the US scans. However, most of these methods are difficult to use for novel users. We proposed an ultrasound calibration method by constructing a phantom from simple Lego bricks and applying an automated multi-slice 2D-3D registration scheme without volumetric reconstruction. The method was validated for its calibration accuracy and reproducibility. Our method yields a calibration accuracy of [Formula: see text] mm and a calibration reproducibility of 1.29 mm. We have proposed a robust, inexpensive, and easy-to-use ultrasound calibration method.

  1. Calibration of a parsimonious distributed ecohydrological daily model in a data-scarce basin by exclusively using the spatio-temporal variation of NDVI

    NASA Astrophysics Data System (ADS)

    Ruiz-Pérez, Guiomar; Koch, Julian; Manfreda, Salvatore; Caylor, Kelly; Francés, Félix

    2017-12-01

    Ecohydrological modeling studies in developing countries, such as sub-Saharan Africa, often face the problem of extensive parametrical requirements and limited available data. Satellite remote sensing data may be able to fill this gap, but require novel methodologies to exploit their spatio-temporal information that could potentially be incorporated into model calibration and validation frameworks. The present study tackles this problem by suggesting an automatic calibration procedure, based on the empirical orthogonal function, for distributed ecohydrological daily models. The procedure is tested with the support of remote sensing data in a data-scarce environment - the upper Ewaso Ngiro river basin in Kenya. In the present application, the TETIS-VEG model is calibrated using only NDVI (Normalized Difference Vegetation Index) data derived from MODIS. The results demonstrate that (1) satellite data of vegetation dynamics can be used to calibrate and validate ecohydrological models in water-controlled and data-scarce regions, (2) the model calibrated using only satellite data is able to reproduce both the spatio-temporal vegetation dynamics and the observed discharge at the outlet and (3) the proposed automatic calibration methodology works satisfactorily and it allows for a straightforward incorporation of spatio-temporal data into the calibration and validation framework of a model.

  2. 40 CFR 600.110-08 - Equipment calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.110-08 Equipment calibration. The equipment used for fuel economy...

  3. 40 CFR 600.110-08 - Equipment calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.110-08 Equipment calibration. The equipment used for fuel economy...

  4. Radiation exposure from fluoroscopy during orthopedic surgical procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, S.A.

    1989-11-01

    The use of fluoroscopy has enabled orthopedic surgeons to become technically more proficient. In addition, these surgical procedures tend to have less associated patient morbidity by decreasing operative time and minimizing the area of the operative field. The trade-off, however, may be an increased risk of radiation exposure to the surgeon on an annual or lifetime basis. The current study was designed to determine the amount of radiation received by the primary surgeon and the first assistant during selected surgical procedures involving the use of fluoroscopy. Five body sites exposed to radiation were monitored for dosage. The results of thismore » study indicate that with appropriate usage, (1) radiation exposure from fluoroscopy is relatively low; (2) the surgeon's dominant hand receives the most exposure per case; and (3) proper maintenance and calibration of fluoroscopic machines are important factors in reducing exposure risks. Therefore, with proper precautions, the use of fluoroscopy in orthopedic procedures can remain a safe practice.« less

  5. Airborne Topographic Mapper Calibration Procedures and Accuracy Assessment

    NASA Technical Reports Server (NTRS)

    Martin, Chreston F.; Krabill, William B.; Manizade, Serdar S.; Russell, Rob L.; Sonntag, John G.; Swift, Robert N.; Yungel, James K.

    2012-01-01

    Description of NASA Airborn Topographic Mapper (ATM) lidar calibration procedures including analysis of the accuracy and consistancy of various ATM instrument parameters and the resulting influence on topographic elevation measurements. The ATM elevations measurements from a nominal operating altitude 500 to 750 m above the ice surface was found to be: Horizontal Accuracy 74 cm, Horizontal Precision 14 cm, Vertical Accuracy 6.6 cm, Vertical Precision 3 cm.

  6. Reflexion measurements for inverse characterization of steel diffusion bond mechanical properties

    NASA Astrophysics Data System (ADS)

    Le Bourdais, Florian; Cachon, Lionel; Rigal, Emmanuel

    2017-02-01

    The present work describes a non-destructive testing method aimed at securing high manufacturing quality of the innovative compact heat exchanger developed under the framework of the CEA R&D program dedicated to the Advanced Sodium Technological Reactor for Industrial Demonstration (ASTRID). The heat exchanger assembly procedure currently proposed involves high temperature and high pressure diffusion welding of stainless steel plates. The aim of the non-destructive method presented herein is to characterize the quality of the welds obtained through this assembly process. Based on a low-frequency model developed by Baik and Thompson [1], pulse-echo normal incidence measurements are calibrated according to a specific procedure and allow the determination of the welding interface stiffness using a nonlinear fitting procedure in the frequency domain. Performing the characterization of plates after diffusion welding using this method allows a useful assessment of the material state as a function of the diffusion bonding process.

  7. Scanning the pressure-induced distortion of fingerprints.

    PubMed

    Mil'shtein, S; Doshi, U

    2004-01-01

    Fingerprint recognition technology is an important part of criminal investigations it is the basis of some security systems and an important tool of government operations such as the Immigration and Naturalization Services, registration procedures in the Armed Forces, and so forth. After the tragic events of September 11, 2001, the importance of reliable fingerprint recognition technology became even more obvious. In the current study, pressure-induced changes of distances between ridges of a fingerprint were measured. Using calibrated silicon pressure sensors we scanned the distribution of pressure across a finger pixel by pixel, and also generated maps of an average pressure distribution during fingerprinting. Emulating the fingerprinting procedure employed with widely used optical scanners, we found that on average the distance between ridges decreases by about 20% when a finger is positioned on a scanner. Controlled loading of a finger demonstrated that it is impossible to reproduce the same distribution of pressure across a given finger during repeated fingerprinting procedures.

  8. Development of a High Accuracy Angular Measurement System for Langley Research Center Hypersonic Wind Tunnel Facilities

    NASA Technical Reports Server (NTRS)

    Newman, Brett; Yu, Si-bok; Rhew, Ray D. (Technical Monitor)

    2003-01-01

    Modern experimental and test activities demand innovative and adaptable procedures to maximize data content and quality while working within severely constrained budgetary and facility resource environments. This report describes development of a high accuracy angular measurement capability for NASA Langley Research Center hypersonic wind tunnel facilities to overcome these deficiencies. Specifically, utilization of micro-electro-mechanical sensors including accelerometers and gyros, coupled with software driven data acquisition hardware, integrated within a prototype measurement system, is considered. Development methodology addresses basic design requirements formulated from wind tunnel facility constraints and current operating procedures, as well as engineering and scientific test objectives. Description of the analytical framework governing relationships between time dependent multi-axis acceleration and angular rate sensor data and the desired three dimensional Eulerian angular state of the test model is given. Calibration procedures for identifying and estimating critical parameters in the sensor hardware is also addressed.

  9. 40 CFR 92.121 - Oxides of nitrogen analyzer calibration and check.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Oxides of nitrogen analyzer... Procedures § 92.121 Oxides of nitrogen analyzer calibration and check. (a) Quench checks; NO X analyzer. (1... performed in step in paragraph (a)(3)(i) this section. (b) Oxides of nitrogen analyzer calibration. (1...

  10. 40 CFR 92.121 - Oxides of nitrogen analyzer calibration and check.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Oxides of nitrogen analyzer... Procedures § 92.121 Oxides of nitrogen analyzer calibration and check. (a) Quench checks; NO X analyzer. (1... performed in step in paragraph (a)(3)(i) this section. (b) Oxides of nitrogen analyzer calibration. (1...

  11. 40 CFR 92.121 - Oxides of nitrogen analyzer calibration and check.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Oxides of nitrogen analyzer... Procedures § 92.121 Oxides of nitrogen analyzer calibration and check. (a) Quench checks; NO X analyzer. (1... performed in step in paragraph (a)(3)(i) this section. (b) Oxides of nitrogen analyzer calibration. (1...

  12. 40 CFR 89.322 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engineering practice. For each range calibrated, if the deviation from a least-squares best-fit straight line... range. If the deviation exceeds these limits, the best-fit non-linear equation which represents the data... interference, system check, and calibration test procedures specified in 40 CFR part 1065 may be used in lieu...

  13. 40 CFR 89.322 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... engineering practice. For each range calibrated, if the deviation from a least-squares best-fit straight line... range. If the deviation exceeds these limits, the best-fit non-linear equation which represents the data... interference, system check, and calibration test procedures specified in 40 CFR part 1065 may be used in lieu...

  14. 40 CFR 89.322 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... engineering practice. For each range calibrated, if the deviation from a least-squares best-fit straight line... range. If the deviation exceeds these limits, the best-fit non-linear equation which represents the data... interference, system check, and calibration test procedures specified in 40 CFR part 1065 may be used in lieu...

  15. 40 CFR 89.322 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... engineering practice. For each range calibrated, if the deviation from a least-squares best-fit straight line... range. If the deviation exceeds these limits, the best-fit non-linear equation which represents the data... interference, system check, and calibration test procedures specified in 40 CFR part 1065 may be used in lieu...

  16. Calibration of solar radiation measuring instruments. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bahm, R J; Nakos, J C

    A review of solar radiation measurement of instruments and some types of errors is given; and procedures for calibrating solar radiation measuring instruments are detailed. An appendix contains a description of various agencies who perform calibration of solar instruments and a description of the methods they used at the time this report was prepared. (WHK)

  17. Calibration Of Airborne Visible/IR Imaging Spectrometer

    NASA Technical Reports Server (NTRS)

    Vane, G. A.; Chrien, T. G.; Miller, E. A.; Reimer, J. H.

    1990-01-01

    Paper describes laboratory spectral and radiometric calibration of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) applied to all AVIRIS science data collected in 1987. Describes instrumentation and procedures used and demonstrates that calibration accuracy achieved exceeds design requirements. Developed for use in remote-sensing studies in such disciplines as botany, geology, hydrology, and oceanography.

  18. Online Calibration of Polytomous Items Under the Generalized Partial Credit Model

    PubMed Central

    Zheng, Yi

    2016-01-01

    Online calibration is a technology-enhanced architecture for item calibration in computerized adaptive tests (CATs). Many CATs are administered continuously over a long term and rely on large item banks. To ensure test validity, these item banks need to be frequently replenished with new items, and these new items need to be pretested before being used operationally. Online calibration dynamically embeds pretest items in operational tests and calibrates their parameters as response data are gradually obtained through the continuous test administration. This study extends existing formulas, procedures, and algorithms for dichotomous item response theory models to the generalized partial credit model, a popular model for items scored in more than two categories. A simulation study was conducted to investigate the developed algorithms and procedures under a variety of conditions, including two estimation algorithms, three pretest item selection methods, three seeding locations, two numbers of score categories, and three calibration sample sizes. Results demonstrated acceptable estimation accuracy of the two estimation algorithms in some of the simulated conditions. A variety of findings were also revealed for the interacted effects of included factors, and recommendations were made respectively. PMID:29881063

  19. Calibration and temperature correction of heat dissipation matric potential sensors

    USGS Publications Warehouse

    Flint, A.L.; Campbell, G.S.; Ellett, K.M.; Calissendorff, C.

    2002-01-01

    This paper describes how heat dissipation sensors, used to measure soil water matric potential, were analyzed to develop a normalized calibration equation and a temperature correction method. Inference of soil matric potential depends on a correlation between the variable thermal conductance of the sensor's porous ceramic and matric poten-tial. Although this correlation varies among sensors, we demonstrate a normalizing procedure that produces a single calibration relationship. Using sensors from three sources and different calibration methods, the normalized calibration resulted in a mean absolute error of 23% over a matric potential range of -0.01 to -35 MPa. Because the thermal conductivity of variably saturated porous media is temperature dependent, a temperature correction is required for application of heat dissipation sensors in field soils. A temperature correction procedure is outlined that reduces temperature dependent errors by 10 times, which reduces the matric potential measurement errors by more than 30%. The temperature dependence is well described by a thermal conductivity model that allows for the correction of measurements at any temperature to measurements at the calibration temperature.

  20. System calibration method for Fourier ptychographic microscopy.

    PubMed

    Pan, An; Zhang, Yan; Zhao, Tianyu; Wang, Zhaojun; Dan, Dan; Lei, Ming; Yao, Baoli

    2017-09-01

    Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  1. Calibration of the Oscillating Screen Viscometer

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    We have devised a calibration procedure for the oscillating screen viscometer which can provide the accuracy needed for the flight measurement of viscosity near the liquid-vapor critical point of xenon. The procedure, which makes use of the viscometer's wide bandwidth and hydrodynamic similarity, allows the viscometer to be self-calibrating. To demonstrate the validity of this procedure we measured the oscillator's transfer function under a wide variety of conditions. We obtained data using CO2 at temperatures spanning a temperature range of 35 K and densities varying by a factor of 165, thereby encountering viscosity variations as great as 50%. In contrast the flight experiment will be performed over a temperature range of 29 K and at only a single density, and the viscosity is expected to change by less than 40%. The measurements show that, after excluding data above 10 Hz (where frequency-dependent corrections are poorly modeled) and making a plausible adjustment to the viscosity value used at high density, the viscometer's behavior is fully consistent with the use of hydrodynamic similarity for calibration. Achieving this agreement required understanding a 1% anelastic effect present in the oscillator's torsion fiber.

  2. An Approach to Remove the Systematic Bias from the Storm Surge forecasts in the Venice Lagoon

    NASA Astrophysics Data System (ADS)

    Canestrelli, A.

    2017-12-01

    In this work a novel approach is proposed for removing the systematic bias from the storm surge forecast computed by a two-dimensional shallow-water model. The model covers both the Adriatic and Mediterranean seas and provides the forecast at the entrance of the Venice Lagoon. The wind drag coefficient at the water-air interface is treated as a calibration parameter, with a different value for each range of wind velocities and wind directions. This sums up to a total of 16-64 parameters to be calibrated, depending on the chosen resolution. The best set of parameters is determined by means of an optimization procedure, which minimizes the RMS error between measured and modeled water level in Venice for the period 2011-2015. It is shown that a bias is present, for which the peaks of wind velocities provided by the weather forecast are largely underestimated, and that the calibration procedure removes this bias. When the calibrated model is used to reproduce events not included in the calibration dataset, the forecast error is strongly reduced, thus confirming the quality of our procedure. The proposed approach it is not site-specific and could be applied to different situations, such as storm surges caused by intense hurricanes.

  3. Novel Real-time Alignment and Calibration of the LHCb detector in Run2

    NASA Astrophysics Data System (ADS)

    Martinelli, Maurizio; LHCb Collaboration

    2017-10-01

    LHCb has introduced a novel real-time detector alignment and calibration strategy for LHC Run2. Data collected at the start of the fill are processed in a few minutes and used to update the alignment parameters, while the calibration constants are evaluated for each run. This procedure improves the quality of the online reconstruction. For example, the vertex locator is retracted and reinserted for stable beam conditions in each fill to be centred on the primary vertex position in the transverse plane. Consequently its position changes on a fill-by-fill basis. Critically, this new real-time alignment and calibration procedure allows identical constants to be used in the online and offline reconstruction, thus improving the correlation between triggered and offline-selected events. This offers the opportunity to optimise the event selection in the trigger by applying stronger constraints. The required computing time constraints are met thanks to a new dedicated framework using the multi-core farm infrastructure for the trigger. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configuration are discussed, as well as the working procedures of the framework and its performance.

  4. Calibrating and Evaluating Boomless Spray Systems for Applying Forest Herbicides

    Treesearch

    Michael A. Wehr; Russell W. Johnson; Robert L. Sajdak

    1985-01-01

    Describes a testing procedure used to calibrate and evaluate agricultureal boomless spray systems. Tests allow the user to obtain dependable and satisfactory results when used in actual forest situations.

  5. Solar panel acceptance testing using a pulsed solar simulator

    NASA Technical Reports Server (NTRS)

    Hershey, T. L.

    1977-01-01

    Utilizing specific parameters as area of an individual cell, number in series and parallel, and established coefficient of current and voltage temperature dependence, a solar array irradiated with one solar constant at AMO and at ambient temperature can be characterized by a current-voltage curve for different intensities, temperatures, and even different configurations. Calibration techniques include: uniformity in area, depth and time, absolute and transfer irradiance standards, dynamic and functional check out procedures. Typical data are given for individual cell (2x2 cm) to complete flat solar array (5x5 feet) with 2660 cells and on cylindrical test items with up to 10,000 cells. The time and energy saving of such testing techniques are emphasized.

  6. Nonlinear, non-stationary image processing technique for eddy current NDE

    NASA Astrophysics Data System (ADS)

    Yang, Guang; Dib, Gerges; Kim, Jaejoon; Zhang, Lu; Xin, Junjun; Udpa, Lalita

    2012-05-01

    Automatic analysis of eddy current (EC) data has facilitated the analysis of large volumes of data generated in the inspection of steam generator tubes in nuclear power plants. The traditional procedure for analysis of EC data includes data calibration, pre-processing, region of interest (ROI) detection, feature extraction and classification. Accurate ROI detection has been enhanced by pre-processing, which involves reducing noise and other undesirable components as well as enhancing defect indications in the raw measurement. This paper presents the Hilbert-Huang Transform (HHT) for feature extraction and support vector machine (SVM) for classification. The performance is shown to significantly better than the existing rule based classification approach used in industry.

  7. Correct calibration procedure for the Q-switched ruby laser and checking the treatment irradiation pattern

    PubMed Central

    Ohshiro, Takafumi; Sasaki, Katsumi; Takenouchi, Kiyofumi; Kozuma, Mituaki; Ohshiro, Naoyuki; Kageyama, Yuichi

    2013-01-01

    Background and aims: There are many Q-switched lasers. The Q-switched ruby laser is the one most popularly used in dermatology, aesthetic surgery and plastic surgery, to remove pigmented lesions or tattoos. Correct and regular calibration of such a system is essential. However, some clinics fail to perform this with the excuse of having no measuring instrument (MI) in their offices or treatment rooms in some of their hospitals or clinics, or even the case of well-known medical universities in Japan. The present article explains the precise calibration procedure and beam pattern checking for the Q-switched ruby systems in the first author's clinic. Rationale: In the case of treatment with a medical laser, the calibration and the irradiated pattern (IP) check of the laser being used for treatment are the most important factors for treatment efficacy and safety. If these factors change, the treatment result could be different from that expected. Such kind of data are not acceptable as scientific information for a presentation or published paper. With such unreliable results and incorrect beam pattern, replicating such a study would be impossible Regular calibration check: In our clinic, we have 2 Q-switched ruby laser systems. On a daily basis, the beam patterns, both the optical axis of the beam and its treatment footprint, are checked on dedicated printed sheets and footprint paper, respectively, at the beginning of the day and after the last procedure. Every two weeks we calibrate our systems in-house using a precise MI. Every six months we calibrate the systems in-house with the MI, and then we send the systems back to the manufacturers for calibration. Once every year, we have our MI calibrated by an accredited facility in Japan. In this way, we are not only ensuring accurate and safe treatment for our patients, but we are also producing accurate system and treatment data which can be replicated by others, the basis of evidence-based medicine. PMID:24204090

  8. Conditional Versus Unconditional Procedures for Sample-Free Item Analysis

    ERIC Educational Resources Information Center

    Wright, Benjamin D.; Douglas, Graham A.

    1977-01-01

    Two procedures for Rasch, sample-free item calibration are reviewed and compared for accuracy. The theoretically ideal "conditional" procedure is impractical for more than fifteen items. The more practical but biased "unconditional" procedure is discussed in detail. (Author/JKS)

  9. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  10. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  11. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  12. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  13. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  14. 40 CFR Appendix F to Part 60 - Quality Assurance Procedures

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... automatically adjust the data to the corrected calibration values (e.g., microprocessor control) must be... calibration values (e.g., microprocessor control), you must program your PM CEMS to record the unadjusted...

  15. 40 CFR 86.1324-84 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Exhaust Test Procedures § 86.1324-84 Carbon dioxide analyzer calibration. Prior to its introduction into...) Follow good engineering practices for instrument start-up and operation. Adjust the analyzer to optimize...

  16. SRAM Detector Calibration

    NASA Technical Reports Server (NTRS)

    Soli, G. A.; Blaes, B. R.; Beuhler, M. G.

    1994-01-01

    Custom proton sensitive SRAM chips are being flown on the BMDO Clementine missions and Space Technology Research Vehicle experiments. This paper describes the calibration procedure for the SRAM proton detectors and their response to the space environment.

  17. SUMS calibration test report

    NASA Technical Reports Server (NTRS)

    Robertson, G.

    1982-01-01

    Calibration was performed on the shuttle upper atmosphere mass spectrometer (SUMS). The results of the calibration and the as run test procedures are presented. The output data is described, and engineering data conversion factors, tables and curves, and calibration on instrument gauges are included. Static calibration results which include: instrument sensitive versus external pressure for N2 and O2, data from each scan of calibration, data plots from N2 and O2, and sensitivity of SUMS at inlet for N2 and O2, and ratios of 14/28 for nitrogen and 16/32 for oxygen are given.

  18. Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

    PubMed

    Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C

    2001-06-01

    This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

  19. Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration

    PubMed Central

    Majarena, Ana C.; Brau, Agustín; Velázquez, Jesús

    2014-01-01

    A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs. Next, a nonlinear optimization algorithm for the identification procedure of the AACMM is explained. An objective function based on Euclidean distances and standard deviations is developed. This function is obtained from the captured nominal data (given by the LTs used as a gauge instrument) and the data obtained by the AACMM and compares the measured and calculated coordinates of the target to obtain the identified model parameters that minimize this difference. Finally, results show that the procedure presented, using the measurements of the LTs as a gauge instrument, is very effective by improving the AACMM precision. PMID:24688418

  20. Calibration of strain-gage installations in aircraft structures for the measurement of flight loads

    NASA Technical Reports Server (NTRS)

    Skopinski, T H; Aiken, William S , Jr; Huston, Wilber B

    1954-01-01

    A general method has been developed for calibrating strain-gage installations in aircraft structures, which permits the measurement in flight of the shear or lift, the bending moment, and the torque or pitching moment on the principal lifting or control surfaces. Although the stress in structural members may not be a simple function of the three loads of interest, a straightforward procedure is given for numerically combining the outputs of several bridges in such a way that the loads may be obtained. Extensions of the basic procedure by means of electrical combination of the strain-gage bridges are described which permit compromises between strain-gage installation time, availability of recording instruments, and data reduction time. The basic principles of strain-gage calibration procedures are illustrated by reference to the data for two aircraft structures of typical construction, one a straight and the other a swept horizontal stabilizer.

  1. Comparison Between One-Point Calibration and Two-Point Calibration Approaches in a Continuous Glucose Monitoring Algorithm

    PubMed Central

    Mahmoudi, Zeinab; Johansen, Mette Dencker; Christiansen, Jens Sandahl

    2014-01-01

    Background: The purpose of this study was to investigate the effect of using a 1-point calibration approach instead of a 2-point calibration approach on the accuracy of a continuous glucose monitoring (CGM) algorithm. Method: A previously published real-time CGM algorithm was compared with its updated version, which used a 1-point calibration instead of a 2-point calibration. In addition, the contribution of the corrective intercept (CI) to the calibration performance was assessed. Finally, the sensor background current was estimated real-time and retrospectively. The study was performed on 132 type 1 diabetes patients. Results: Replacing the 2-point calibration with the 1-point calibration improved the CGM accuracy, with the greatest improvement achieved in hypoglycemia (18.4% median absolute relative differences [MARD] in hypoglycemia for the 2-point calibration, and 12.1% MARD in hypoglycemia for the 1-point calibration). Using 1-point calibration increased the percentage of sensor readings in zone A+B of the Clarke error grid analysis (EGA) in the full glycemic range, and also enhanced hypoglycemia sensitivity. Exclusion of CI from calibration reduced hypoglycemia accuracy, while slightly increased euglycemia accuracy. Both real-time and retrospective estimation of the sensor background current suggest that the background current can be considered zero in the calibration of the SCGM1 sensor. Conclusions: The sensor readings calibrated with the 1-point calibration approach indicated to have higher accuracy than those calibrated with the 2-point calibration approach. PMID:24876420

  2. Solar Cell Calibration and Measurement Techniques

    NASA Technical Reports Server (NTRS)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    1997-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WDI 5387, 'Requirements for Measurement and Calibration Procedures for Space Solar Cells' was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and the international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  3. Solar Cell Calibration and Measurement Techniques

    NASA Technical Reports Server (NTRS)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    2004-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  4. Short-Chain Polysaccharide Analysis in Ethanol-Water Solutions.

    PubMed

    Yan, Xun

    2017-07-01

    This study demonstrates that short-chain polysaccharides, or oligosaccharides, could be sufficiently separated with hydrophilic interaction LC (HILIC) conditions and quantified by evaporative light-scattering detection (ELSD). The multianalyte calibration approach improved the efficiency of calibrating the nonlinear detector response. The method allowed easy quantification of short-chain carbohydrates. Using the HILIC method, the oligosaccharide solubility and its profile in water/alcohol solutions at room temperature were able to be quantified. The results showed that the polysaccharide solubility in ethanol-water solutions decreased as ethanol content increased. The results also showed oligosaccharides to have minimal solubility in pure ethanol. In a saturated maltodextrin ethanol (80%) solution, oligosaccharide components with a degree of polymerization >12 were practically insoluble and contributed less than 0.2% to the total solute dry weight. The HILIC-ELSD method allows for the identification and quantification of low-MW carbohydrates individually and served as an alternative method to current gel permeation chromatography procedures.

  5. Standard Reference Specimens in Quality Control of Engineering Surfaces

    PubMed Central

    Song, J. F.; Vorburger, T. V.

    1991-01-01

    In the quality control of engineering surfaces, we aim to understand and maintain a good relationship between the manufacturing process and surface function. This is achieved by controlling the surface texture. The control process involves: 1) learning the functional parameters and their control values through controlled experiments or through a long history of production and use; 2) maintaining high accuracy and reproducibility with measurements not only of roughness calibration specimens but also of real engineering parts. In this paper, the characteristics, utilizations, and limitations of different classes of precision roughness calibration specimens are described. A measuring procedure of engineering surfaces, based on the calibration procedure of roughness specimens at NIST, is proposed. This procedure involves utilization of check specimens with waveform, wavelength, and other roughness parameters similar to functioning engineering surfaces. These check specimens would be certified under standardized reference measuring conditions, or by a reference instrument, and could be used for overall checking of the measuring procedure and for maintaining accuracy and agreement in engineering surface measurement. The concept of “surface texture design” is also suggested, which involves designing the engineering surface texture, the manufacturing process, and the quality control procedure to meet the optimal functional needs. PMID:28184115

  6. A Procedure to Measure the in-Situ Hygrothermal Behavior of Earth Walls

    PubMed Central

    Chabriac, Pierre-Antoine; Fabbri, Antonin; Morel, Jean-Claude; Laurent, Jean-Paul; Blanc-Gonnet, Joachim

    2014-01-01

    Rammed earth is a sustainable material with low embodied energy. However, its development as a building material requires a better evaluation of its moisture-thermal buffering abilities and its mechanical behavior. Both of these properties are known to strongly depend on the amount of water contained in wall pores and its evolution. Thus the aim of this paper is to present a procedure to measure this key parameter in rammed earth or cob walls by using two types of probes operating on the Time Domain Reflectometry (TDR) principle. A calibration procedure for the probes requiring solely four parameters is described. This calibration procedure is then used to monitor the hygrothermal behavior of a rammed earth wall (1.5 m × 1 m × 0.5 m), instrumented by six probes during its manufacture, and submitted to insulated, natural convection and forced convection conditions. These measurements underline the robustness of the calibration procedure over a large range of water content, even if the wall is submitted to quite important temperature variations. They also emphasize the importance of gravity on water content heterogeneity when the saturation is high, as well as the role of liquid-to-vapor phase change on the thermal behavior. PMID:28788603

  7. First test results of the airborne dispersive pushbroom imaging spectrometer APEX

    NASA Astrophysics Data System (ADS)

    Meuleman, K.; Itten, K.; Schaepman, M.

    2009-04-01

    APEX, ESA-Prodex "Airborne Prism Experiment" comprises the development of an airborne dispersive pushbroom imaging spectrometer and has originally been designed as flexible hyperspectral mission simulator and calibrator for existing and upcoming or planned future space missions. The APEX project is co-funded by Switzerland and Belgium and built by a Belgian-Swiss industrial team under the prime RUAG Aerospace (CH), responsible for the total system and the mechanical components, OIP (Oudenaarde, BE) contributing the spectrometer, and Netcetera (Zurich, CH) being responsible for the electronics. RSL (University of Zurich, CH) acts as scientific PI together with the Co-PI VITO (Mol, BE). The APEX sensor is operating between 380 nm and 2500 nm in more than 300 freely configurable bands (up to 512 bands in full spectral mode), by means of two dispersive spectrometer channels. 1000 pixels across track and a total field of view of 28° define the ground pixel size (e.g. 2,5 m from 5000 m AGL). A stabilized platform (Leica PAV-30) reduces major geometric distortions due to aircraft instabilities while a GPS/IMU system (Applanix PosAV 410) measures continuously the sensors' position and orientation allowing direct georeferencing of the acquired data . The system is currently is phase D, the calibration and test phase, and first testflights have been performed on a Do-228 in cooperation of DLR while the acquired data is currently under evaluation. Discussions are ongoing to fly APEX on the new DLR High Altitude Research Aircraft (HALO) as well. The system is currently in phase D, the calibration and test phase, and will deliver first scientific data to users by mid 2009. The APEX processing and archiving facility (PAF) is hosted by VITO in the APEX Operations Center (AOC) at Mol, Belgium . A specific level 0-1 processing software module producing uniform, radiometrically calibrated data has been developed by RSL and is integrated into the PAF by VITO. An APEX Calibration Home Base has been developed at DLR and serves as generic institution for the calibration of imaging spectrometers. Since special emphasis is on delivering reliable, well calibrated data, an in-flight calibration tool in form of a diffuser disk and specific absorption filters are used to monitor the stability of the APEX system. We anticipate major application innovations in limnology and coastal oceans research, atmospheric studies, in agriculture as well as land use and ecosystems mapping and monitoring, in geology and security questions.. The paper describes the APEX system, overall specifications as well as system validation procedures and preliminary performance results. A 5-year's exploitation phase is planned form mid 2009 onwards. The programme and flight opportunities will be addressed, and researchers invited to propose experiments.

  8. Desing of Digital Calliper for Control of Selected Parameters of Railway Wheels

    NASA Astrophysics Data System (ADS)

    Ticha, Šarka; Zelnak, Michal; Vavrina, Jan

    2014-12-01

    This contribution deals with new design of digital calliper for transferring of width dimension scale from the ring interface to tyre of railway wheel. Based on the problem definition were solved variants of design with possibility of improvement current measurement technique. For selected variant of production was developed calibration procedures for ensure of required accuracy. At the end solution that was significantly influenced by economic recession was realized variant for single production. Manufacturer and exclusive supplier of this digital calliper is UNIMETRA Company, Ltd.

  9. Use of Spectralon as a diffuse reflectance standard for in-flight calibration of earth-orbiting sensors

    NASA Technical Reports Server (NTRS)

    Bruegge, Carol J.; Stiegman, Albert E.; Rainen, Richard A.; Springsteen, Arthur W.

    1993-01-01

    Spectralon, a commercially available diffuse reflectance material made from polytetrafluoroethylene (PTFE), is being evaluated for the multiangle imaging spectroradiometer (MISR), currently under development for the Earth Observing System. Results of a series of environmental exposure tests indicate that no degradation of the optical properties was apparent following proton bombardment, and stability through UV illumination was satisfactory, provided simple cleaning and handling procedures were implemented. A buildup of several thousand volts of static charge was found to develop while simulating a rare pass through an auroral storm.

  10. Initial processing and analysis of forward- and side-looking data from the Spectrally Agile Frequency-Incrementing Reconfigurable (SAFIRE) radar

    NASA Astrophysics Data System (ADS)

    Ranney, Kenneth; Phelan, Brian; Sherbondy, Kelly; Kirose, Getachew; Smith, Gregory; Clark, John; Harrison, Arthur; Ressler, Marc; Nguyen, Lam; Narayanan, Ram

    2017-05-01

    A new, versatile, UHF/L band, ultrawideband (UWB), vehicle-mounted radar system developed at the U.S. Army Research Laboratory (ARL) has recently been exercised at an arid U.S. test site. The unique switching scheme implemented to record data from all receive channels is described, along with the current calibration procedure. Radar and global positioning system (GPS) data collected in both forwardand side-looking configurations are processed, and synthetic aperture radar (SAR) images are formed. Results are presented for various target emplacement scenarios.

  11. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... affect the range used to report patient test results, and control values are not adversely affected by... that may influence test performance. (iii) Control materials reflect an unusual trend or shift, or are...

  12. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... affect the range used to report patient test results, and control values are not adversely affected by... that may influence test performance. (iii) Control materials reflect an unusual trend or shift, or are...

  13. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... affect the range used to report patient test results, and control values are not adversely affected by... that may influence test performance. (iii) Control materials reflect an unusual trend or shift, or are...

  14. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... affect the range used to report patient test results, and control values are not adversely affected by... that may influence test performance. (iii) Control materials reflect an unusual trend or shift, or are...

  15. A Bayesian procedure for evaluating the frequency of calibration factor updates in highway safety manual (HSM) applications.

    PubMed

    Saha, Dibakar; Alluri, Priyanka; Gan, Albert

    2017-01-01

    The Highway Safety Manual (HSM) presents statistical models to quantitatively estimate an agency's safety performance. The models were developed using data from only a few U.S. states. To account for the effects of the local attributes and temporal factors on crash occurrence, agencies are required to calibrate the HSM-default models for crash predictions. The manual suggests updating calibration factors every two to three years, or preferably on an annual basis. Given that the calibration process involves substantial time, effort, and resources, a comprehensive analysis of the required calibration factor update frequency is valuable to the agencies. Accordingly, the objective of this study is to evaluate the HSM's recommendation and determine the required frequency of calibration factor updates. A robust Bayesian estimation procedure is used to assess the variation between calibration factors computed annually, biennially, and triennially using data collected from over 2400 miles of segments and over 700 intersections on urban and suburban facilities in Florida. Bayesian model yields a posterior distribution of the model parameters that give credible information to infer whether the difference between calibration factors computed at specified intervals is credibly different from the null value which represents unaltered calibration factors between the comparison years or in other words, zero difference. The concept of the null value is extended to include the range of values that are practically equivalent to zero. Bayesian inference shows that calibration factors based on total crash frequency are required to be updated every two years in cases where the variations between calibration factors are not greater than 0.01. When the variations are between 0.01 and 0.05, calibration factors based on total crash frequency could be updated every three years. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Dynamic trends in cardiac surgery: why the logistic EuroSCORE is no longer suitable for contemporary cardiac surgery and implications for future risk models

    PubMed Central

    Hickey, Graeme L.; Grant, Stuart W.; Murphy, Gavin J.; Bhabra, Moninder; Pagano, Domenico; McAllister, Katherine; Buchan, Iain; Bridgewater, Ben

    2013-01-01

    OBJECTIVES Progressive loss of calibration of the original EuroSCORE models has necessitated the introduction of the EuroSCORE II model. Poor model calibration has important implications for clinical decision-making and risk adjustment of governance analyses. The objective of this study was to explore the reasons for the calibration drift of the logistic EuroSCORE. METHODS Data from the Society for Cardiothoracic Surgery in Great Britain and Ireland database were analysed for procedures performed at all National Health Service and some private hospitals in England and Wales between April 2001 and March 2011. The primary outcome was in-hospital mortality. EuroSCORE risk factors, overall model calibration and discrimination were assessed over time. RESULTS A total of 317 292 procedures were included. Over the study period, mean age at surgery increased from 64.6 to 67.2 years. The proportion of procedures that were isolated coronary artery bypass grafts decreased from 67.5 to 51.2%. In-hospital mortality fell from 4.1 to 2.8%, but the mean logistic EuroSCORE increased from 5.6 to 7.6%. The logistic EuroSCORE remained a good discriminant throughout the study period (area under the receiver-operating characteristic curve between 0.79 and 0.85), but calibration (observed-to-expected mortality ratio) fell from 0.76 to 0.37. Inadequate adjustment for decreasing baseline risk affected calibration considerably. DISCUSSIONS Patient risk factors and case-mix in adult cardiac surgery change dynamically over time. Models like the EuroSCORE that are developed using a ‘snapshot’ of data in time do not account for this and can subsequently lose calibration. It is therefore important to regularly revalidate clinical prediction models. PMID:23152436

  17. Calibration of groundwater vulnerability mapping using the generalized reduced gradient method.

    PubMed

    Elçi, Alper

    2017-12-01

    Groundwater vulnerability assessment studies are essential in water resources management. Overlay-and-index methods such as DRASTIC are widely used for mapping of groundwater vulnerability, however, these methods mainly suffer from a subjective selection of model parameters. The objective of this study is to introduce a calibration procedure that results in a more accurate assessment of groundwater vulnerability. The improvement of the assessment is formulated as a parameter optimization problem using an objective function that is based on the correlation between actual groundwater contamination and vulnerability index values. The non-linear optimization problem is solved with the generalized-reduced-gradient (GRG) method, which is numerical algorithm based optimization method. To demonstrate the applicability of the procedure, a vulnerability map for the Tahtali stream basin is calibrated using nitrate concentration data. The calibration procedure is easy to implement and aims the maximization of correlation between observed pollutant concentrations and groundwater vulnerability index values. The influence of each vulnerability parameter in the calculation of the vulnerability index is assessed by performing a single-parameter sensitivity analysis. Results of the sensitivity analysis show that all factors are effective on the final vulnerability index. Calibration of the vulnerability map improves the correlation between index values and measured nitrate concentrations by 19%. The regression coefficient increases from 0.280 to 0.485. It is evident that the spatial distribution and the proportions of vulnerability class areas are significantly altered with the calibration process. Although the applicability of the calibration method is demonstrated on the DRASTIC model, the applicability of the approach is not specific to a certain model and can also be easily applied to other overlay-and-index methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Calibration of groundwater vulnerability mapping using the generalized reduced gradient method

    NASA Astrophysics Data System (ADS)

    Elçi, Alper

    2017-12-01

    Groundwater vulnerability assessment studies are essential in water resources management. Overlay-and-index methods such as DRASTIC are widely used for mapping of groundwater vulnerability, however, these methods mainly suffer from a subjective selection of model parameters. The objective of this study is to introduce a calibration procedure that results in a more accurate assessment of groundwater vulnerability. The improvement of the assessment is formulated as a parameter optimization problem using an objective function that is based on the correlation between actual groundwater contamination and vulnerability index values. The non-linear optimization problem is solved with the generalized-reduced-gradient (GRG) method, which is numerical algorithm based optimization method. To demonstrate the applicability of the procedure, a vulnerability map for the Tahtali stream basin is calibrated using nitrate concentration data. The calibration procedure is easy to implement and aims the maximization of correlation between observed pollutant concentrations and groundwater vulnerability index values. The influence of each vulnerability parameter in the calculation of the vulnerability index is assessed by performing a single-parameter sensitivity analysis. Results of the sensitivity analysis show that all factors are effective on the final vulnerability index. Calibration of the vulnerability map improves the correlation between index values and measured nitrate concentrations by 19%. The regression coefficient increases from 0.280 to 0.485. It is evident that the spatial distribution and the proportions of vulnerability class areas are significantly altered with the calibration process. Although the applicability of the calibration method is demonstrated on the DRASTIC model, the applicability of the approach is not specific to a certain model and can also be easily applied to other overlay-and-index methods.

  19. Procedure for the Selection and Validation of a Calibration Model I-Description and Application.

    PubMed

    Desharnais, Brigitte; Camirand-Lemyre, Félix; Mireault, Pascal; Skinner, Cameron D

    2017-05-01

    Calibration model selection is required for all quantitative methods in toxicology and more broadly in bioanalysis. This typically involves selecting the equation order (quadratic or linear) and weighting factor correctly modelizing the data. A mis-selection of the calibration model will generate lower quality control (QC) accuracy, with an error up to 154%. Unfortunately, simple tools to perform this selection and tests to validate the resulting model are lacking. We present a stepwise, analyst-independent scheme for selection and validation of calibration models. The success rate of this scheme is on average 40% higher than a traditional "fit and check the QCs accuracy" method of selecting the calibration model. Moreover, the process was completely automated through a script (available in Supplemental Data 3) running in RStudio (free, open-source software). The need for weighting was assessed through an F-test using the variances of the upper limit of quantification and lower limit of quantification replicate measurements. When weighting was required, the choice between 1/x and 1/x2 was determined by calculating which option generated the smallest spread of weighted normalized variances. Finally, model order was selected through a partial F-test. The chosen calibration model was validated through Cramer-von Mises or Kolmogorov-Smirnov normality testing of the standardized residuals. Performance of the different tests was assessed using 50 simulated data sets per possible calibration model (e.g., linear-no weight, quadratic-no weight, linear-1/x, etc.). This first of two papers describes the tests, procedures and outcomes of the developed procedure using real LC-MS-MS results for the quantification of cocaine and naltrexone. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Methods to produce calibration mixtures for anesthetic gas monitors and how to perform volumetric calculations on anesthetic gases.

    PubMed

    Christensen, P L; Nielsen, J; Kann, T

    1992-10-01

    A simple procedure for making calibration mixtures of oxygen and the anesthetic gases isoflurane, enflurane, and halothane is described. One to ten grams of the anesthetic substance is evaporated in a closed, 11,361-cc glass bottle filled with oxygen gas at atmospheric pressure. The carefully mixed gas is used to calibrate anesthetic gas monitors. By comparison of calculated and measured volumetric results it is shown that at atmospheric conditions the volumetric behavior of anesthetic gas mixtures can be described with reasonable accuracy using the ideal gas law. A procedure is described for calculating the deviation from ideal gas behavior in cases in which this is needed.

  1. GIFTS SM EDU Radiometric and Spectral Calibrations

    NASA Technical Reports Server (NTRS)

    Tian, J.; Reisse, R. a.; Johnson, D. G.; Gazarik, J. J.

    2007-01-01

    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

  2. Calibration of the ROSAT HRI Spectral Response

    NASA Technical Reports Server (NTRS)

    Prestwich, Andrea

    1998-01-01

    The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases-with time and also is a function of position on the detector. To complicate matters further, the satellite is "wobbled", possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT HRI from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

  3. Calibration of the ROSAT HRI Spectral Response

    NASA Technical Reports Server (NTRS)

    Prestwich, Andrea H.; Silverman, John; McDowell, Jonathan; Callanan, Paul; Snowden, Steve

    2000-01-01

    The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases with time and also is a function of position on the detector. To complicate matters further, the satellite is 'wobbled', possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT High Resolution Imager (HRI) from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC (an x ray spectral fitting package) response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how, the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

  4. Utilization of Expert Knowledge in a Multi-Objective Hydrologic Model Automatic Calibration Process

    NASA Astrophysics Data System (ADS)

    Quebbeman, J.; Park, G. H.; Carney, S.; Day, G. N.; Micheletty, P. D.

    2016-12-01

    Spatially distributed continuous simulation hydrologic models have a large number of parameters for potential adjustment during the calibration process. Traditional manual calibration approaches of such a modeling system is extremely laborious, which has historically motivated the use of automatic calibration procedures. With a large selection of model parameters, achieving high degrees of objective space fitness - measured with typical metrics such as Nash-Sutcliffe, Kling-Gupta, RMSE, etc. - can easily be achieved using a range of evolutionary algorithms. A concern with this approach is the high degree of compensatory calibration, with many similarly performing solutions, and yet grossly varying parameter set solutions. To help alleviate this concern, and mimic manual calibration processes, expert knowledge is proposed for inclusion within the multi-objective functions, which evaluates the parameter decision space. As a result, Pareto solutions are identified with high degrees of fitness, but also create parameter sets that maintain and utilize available expert knowledge resulting in more realistic and consistent solutions. This process was tested using the joint SNOW-17 and Sacramento Soil Moisture Accounting method (SAC-SMA) within the Animas River basin in Colorado. Three different elevation zones, each with a range of parameters, resulted in over 35 model parameters simultaneously calibrated. As a result, high degrees of fitness were achieved, in addition to the development of more realistic and consistent parameter sets such as those typically achieved during manual calibration procedures.

  5. Nuclear Gauge Calibration and Testing Guidelines for Hawaii

    DOT National Transportation Integrated Search

    2006-12-15

    Project proposal brief: AASHTO and ASTM nuclear gauge testing procedures can lead to misleading density and moisture readings for certain Hawaiian soils. Calibration curves need to be established for these unique materials, along with clear standard ...

  6. 40 CFR 1066.310 - Coastdown procedures for vehicles above 14,000 pounds GVWR.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Calibrate the equipment by running the zero-wind and zero-angle calibrations within 24 hours before... = mean ambient absolute temperature during testing, in K. p act = average ambient pressuring during the...

  7. Airport Landside - Volume III : ALSIM Calibration and Validation.

    DOT National Transportation Integrated Search

    1982-06-01

    This volume discusses calibration and validation procedures applied to the Airport Landside Simulation Model (ALSIM), using data obtained at Miami, Denver and LaGuardia Airports. Criteria for the selection of a validation methodology are described. T...

  8. Modeling and characterization of the Earth Radiation Budget Experiment (ERBE) nonscanner and scanner sensors

    NASA Technical Reports Server (NTRS)

    Halyo, Nesim; Pandey, Dhirendra K.; Taylor, Deborah B.

    1989-01-01

    The Earth Radiation Budget Experiment (ERBE) is making high-absolute-accuracy measurements of the reflected solar and Earth-emitted radiation as well as the incoming solar radiation from three satellites: ERBS, NOAA-9, and NOAA-10. Each satellite has four Earth-looking nonscanning radiometers and three scanning radiometers. A fifth nonscanner, the solar monitor, measures the incoming solar radiation. The development of the ERBE sensor characterization procedures are described using the calibration data for each of the Earth-looking nonscanners and scanners. Sensor models for the ERBE radiometers are developed including the radiative exchange, conductive heat flow, and electronics processing for transient and steady state conditions. The steady state models are used to interpret the sensor outputs, resulting in the data reduction algorithms for the ERBE instruments. Both ground calibration and flight calibration procedures are treated and analyzed. The ground and flight calibration coefficients for the data reduction algorithms are presented.

  9. NASA Glenn Icing Research Tunnel: Upgrade and Cloud Calibration

    NASA Technical Reports Server (NTRS)

    VanZante, Judith Foss; Ide, Robert F.; Steen, Laura E.

    2012-01-01

    In 2011, NASA Glenn s Icing Research Tunnel underwent a major modification to it s refrigeration plant and heat exchanger. This paper presents the results of the subsequent full cloud calibration. Details of the calibration procedure and results are presented herein. The steps include developing a nozzle transfer map, establishing a uniform cloud, conducting a drop sizing calibration and finally a liquid water content calibration. The goal of the calibration is to develop a uniform cloud, and to build a transfer map from the inputs of air speed, spray bar atomizing air pressure and water pressure to the output of median volumetric droplet diameter and liquid water content.

  10. Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

    NASA Technical Reports Server (NTRS)

    Vane, Gregg; Chrien, Thomas G.; Miller, Edward A.; Reimer, John H.

    1987-01-01

    The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

  11. Validating and comparing GNSS antenna calibrations

    NASA Astrophysics Data System (ADS)

    Kallio, Ulla; Koivula, Hannu; Lahtinen, Sonja; Nikkonen, Ville; Poutanen, Markku

    2018-03-01

    GNSS antennas have no fixed electrical reference point. The variation of the phase centre is modelled and tabulated in antenna calibration tables, which include the offset vector (PCO) and phase centre variation (PCV) for each frequency according to the elevations and azimuths of the incoming signal. Used together, PCV and PCO reduce the phase observations to the antenna reference point. The remaining biases, called the residual offsets, can be revealed by circulating and rotating the antennas on pillars. The residual offsets are estimated as additional parameters when combining the daily GNSS network solutions with full covariance matrix. We present a procedure for validating the antenna calibration tables. The dedicated test field, called Revolver, was constructed at Metsähovi. We used the procedure to validate the calibration tables of 17 antennas. Tables from the IGS and three different calibration institutions were used. The tests show that we were able to separate the residual offsets at the millimetre level. We also investigated the influence of the calibration tables from the different institutions on site coordinates by performing kinematic double-difference baseline processing of the data from one site with different antenna tables. We found small but significant differences between the tables.

  12. Transferable Calibration Standard Developed for Quantitative Raman Scattering Diagnostics in High-Pressure Flames

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet; Kojima, Jun

    2005-01-01

    Researchers from NASA Glenn Research Center s Combustion Branch and the Ohio Aerospace Institute (OAI) have developed a transferable calibration standard for an optical technique called spontaneous Raman scattering (SRS) in high-pressure flames. SRS is perhaps the only technique that provides spatially and temporally resolved, simultaneous multiscalar measurements in turbulent flames. Such measurements are critical for the validation of numerical models of combustion. This study has been a combined experimental and theoretical effort to develop a spectral calibration database for multiscalar diagnostics using SRS in high-pressure flames. However, in the past such measurements have used a one-of-a-kind experimental setup and a setup-dependent calibration procedure to empirically account for spectral interferences, or crosstalk, among the major species of interest. Such calibration procedures, being non-transferable, are prohibitively expensive to duplicate. A goal of this effort is to provide an SRS calibration database using transferable standards that can be implemented widely by other researchers for both atmospheric-pressure and high-pressure (less than 30 atm) SRS studies. A secondary goal of this effort is to provide quantitative multiscalar diagnostics in high pressure environments to validate computational combustion codes.

  13. A new approach for the pixel map sensitivity (PMS) evaluation of an electronic portal imaging device (EPID)

    PubMed Central

    Lucio, Francesco; Calamia, Elisa; Russi, Elvio; Marchetto, Flavio

    2013-01-01

    When using an electronic portal imaging device (EPID) for dosimetric verifications, the calibration of the sensitive area is of paramount importance. Two calibration methods are generally adopted: one, empirical, based on an external reference dosimeter or on multiple narrow beam irradiations, and one based on the EPID response simulation. In this paper we present an alternative approach based on an intercalibration procedure, independent from external dosimeters and from simulations, and is quick and easy to perform. Each element of a detector matrix is characterized by a different gain; the aim of the calibration procedure is to relate the gain of each element to a reference one. The method that we used to compute the relative gains is based on recursive acquisitions with the EPID placed in different positions, assuming a constant fluence of the beam for subsequent deliveries. By applying an established procedure and analysis algorithm, the EPID calibration was repeated in several working conditions. Data show that both the photons energy and the presence of a medium between the source and the detector affect the calibration coefficients less than 1%. The calibration coefficients were then applied to the acquired images, comparing the EPID dose images with films. Measurements were performed with open field, placing the film at the level of the EPID. The standard deviation of the distribution of the point‐to‐point difference is 0.6%. An approach of this type for the EPID calibration has many advantages with respect to the standard methods — it does not need an external dosimeter, it is not related to the irradiation techniques, and it is easy to implement in the clinical practice. Moreover, it can be applied in case of transit or nontransit dosimetry, solving the problem of the EPID calibration independently from the dose reconstruction method. PACS number: 87.56.‐v PMID:24257285

  14. SU-C-202-07: Protocol and Hardware for Improved Flood Field Calibration of TrueBeam FFF Cine Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamson, J; Faught, A; Yin, F

    2016-06-15

    Purpose: Flattening filter free photon energies are commonly used for high dose treatments such as SBRT, where localization accuracy is essential. Often, MV cine imaging may be employed to verify correct localization. TrueBeam Electronic Portal Imaging Devices (EPIDs) equipped with the 40×30cm{sup 2} Image Detection Unit (IDU) are prone to image saturation at the image center especially for higher dose rates. While saturation often does not occur for cine imaging during treatment because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Here we describe the hardware and protocolmore » to achieve improved image quality for this model of TrueBeam EPID. Methods: A stainless steel filter of uniform thickness was designed to have sufficient attenuation to avoid panel saturation for both 6XFFF and 10XFFF at the maximum dose rates (1400 MU/min & 2400 MU/min, respectively). The cine imaging flood field calibration was then acquired with the filter in place for the FFF energies under the standard calibration geometry (SDD=150cm). Image quality during MV cine was assessed with & without the modified flood field calibration using a low contrast resolution phantom and an anthropomorphic phantom. Results: When the flood field is acquired using the standard procedure (no filter in place), a pixel gain artifact is clearly present in the image center (r=3cm for 10XFFF at 2400 MU/min) which appears similar to and may be mis-attributed to panel saturation in the subject image. The artifact obscured all low contrast inserts at the image center and was also visible on the anthropomorphic phantom. Using the filter for flood field calibration eliminated the artifact. Conclusion: Use of a modified flood field calibration procedure improves image quality for cine MV imaging with TrueBeams equipped with the 40×30cm{sup 2} IDU.« less

  15. Defining and Verifying Research Grade Airborne Laser Swath Mapping (ALSM) Observations

    NASA Astrophysics Data System (ADS)

    Carter, W. E.; Shrestha, R. L.; Slatton, C. C.

    2004-12-01

    The first and primary goal of the National Science Foundation (NSF) supported Center for Airborne Laser Mapping (NCALM), operated jointly by the University of Florida and the University of California, Berkeley, is to make "research grade" ALSM data widely available at affordable cost to the national scientific community. Cost aside, researchers need to know what NCALM considers research grade data and how the quality of the data is verified, to be able to determine the likelihood that the data they receive will meet their project specific requirements. Given the current state of the technology it is reasonable to expect a well planned and executed survey to produce surface elevations with uncertainties less than 10 centimeters and horizontal uncertainties of a few decimeters. Various components of the total error are generally associated with the aircraft trajectory, aircraft orientation, or laser vectors. Aircraft trajectory error is dependent largely on the Global Positioning System (GPS) observations, aircraft orientation on Inertial Measurement Unit (IMU) observations, and laser vectors on the scanning and ranging instrumentation. In addition to the issue of the precision or accuracy of the coordinates of the surface points, consideration must also be given to the point-to-point spacing and voids in the coverage. The major sources of error produce distinct artifacts in the data set. For example, aircraft trajectory errors tend to change slowly as the satellite constellation geometry varies, producing slopes within swaths and offsets between swaths. Roll, pitch and yaw biases in the IMU observations tend to persist through whole flights, and created distinctive artifacts in the swath overlap areas. Errors in the zero-point and scale of the laser scanner cause the edges of swaths to turn up or down. Range walk errors cause offsets between bright and dark surfaces, causing paint stripes to float above the dark surfaces of roads. The three keys to producing research grade ALSM observations are calibration, calibration, calibration. In this paper we discuss our general calibrations procedures, give examples of project specific calibration procedures, and discuss the use of ground truth data to verify the accuracy of ALSM surface coordinates.

  16. The Calibration and error analysis of Shallow water (less than 100m) Multibeam Echo-Sounding System

    NASA Astrophysics Data System (ADS)

    Lin, M.

    2016-12-01

    Multibeam echo-sounders(MBES) have been developed to gather bathymetric and acoustic data for more efficient and more exact mapping of the oceans. This gain in efficiency does not come without drawbacks. Indeed, the finer the resolution of remote sensing instruments, the harder they are to calibrate. This is the case for multibeam echo-sounding systems (MBES). We are no longer dealing with sounding lines where the bathymetry must be interpolated between them to engender consistent representations of the seafloor. We now need to match together strips (swaths) of totally ensonified seabed. As a consequence, misalignment and time lag problems emerge as artifacts in the bathymetry from adjacent or overlapping swaths, particularly when operating in shallow water. More importantly, one must still verify that bathymetric data meet the accuracy requirements. This paper aims to summarize the system integration involved with MBES and identify the various source of error pertaining to shallow water survey (100m and less). A systematic method for the calibration of shallow water MBES is proposed and presented as a set of field procedures. The procedures aim at detecting, quantifying and correcting systematic instrumental and installation errors. Hence, calibrating for variations of the speed of sound in the water column, which is natural in origin, is not addressed in this document. The data which used in calibration will reference International Hydrographic Organization(IHO) and other related standards to compare. This paper aims to set a model in the specific area which can calibrate the error due to instruments. We will construct a procedure in patch test and figure out all the possibilities may make sounding data with error then calculate the error value to compensate. In general, the problems which have to be solved is the patch test's 4 correction in the Hypack system 1.Roll 2.GPS Latency 3.Pitch 4.Yaw. Cause These 4 correction affect each others, we run each survey line to calibrate. GPS Latency is synchronized GPS to echo sounder. Future studies concerning any shallower portion of an area, by this procedure can be more accurate sounding value and can do more detailed research.

  17. TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen-Mayer, H; Judy, P; Fain, S

    Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze themore » images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).« less

  18. Stepwise calibration procedure for regional coupled hydrological-hydrogeological models

    NASA Astrophysics Data System (ADS)

    Labarthe, Baptiste; Abasq, Lena; de Fouquet, Chantal; Flipo, Nicolas

    2014-05-01

    Stream-aquifer interaction is a complex process depending on regional and local processes. Indeed, the groundwater component of hydrosystem and large scale heterogeneities control the regional flows towards the alluvial plains and the rivers. In second instance, the local distribution of the stream bed permeabilities controls the dynamics of stream-aquifer water fluxes within the alluvial plain, and therefore the near-river piezometric head distribution. In order to better understand the water circulation and pollutant transport in watersheds, the integration of these multi-dimensional processes in modelling platform has to be performed. Thus, the nested interfaces concept in continental hydrosystem modelling (where regional fluxes, simulated by large scale models, are imposed at local stream-aquifer interfaces) has been presented in Flipo et al (2014). This concept has been implemented in EauDyssée modelling platform for a large alluvial plain model (900km2) part of a 11000km2 multi-layer aquifer system, located in the Seine basin (France). The hydrosystem modelling platform is composed of four spatially distributed modules (Surface, Sub-surface, River and Groundwater), corresponding to four components of the terrestrial water cycle. Considering the large number of parameters to be inferred simultaneously, the calibration process of coupled models is highly computationally demanding and therefore hardly applicable to a real case study of 10000km2. In order to improve the efficiency of the calibration process, a stepwise calibration procedure is proposed. The stepwise methodology involves determining optimal parameters of all components of the coupled model, to provide a near optimum prior information for the global calibration. It starts with the surface component parameters calibration. The surface parameters are optimised based on the comparison between simulated and observed discharges (or filtered discharges) at various locations. Once the surface parameters have been determined, the groundwater component is calibrated. The calibration procedure is performed under steady state hypothesis (to minimize the procedure time length) using recharge rates given by the surface component calibration and imposed fluxes boundary conditions given by the regional model. The calibration is performed using pilot point where the prior variogram is calculated from observed transmissivities values. This procedure uses PEST (http//:www.pesthomepage.org/Home.php) as the inverse modelling tool and EauDyssée as the direct model. During the stepwise calibration process, each modules, even if they are actually dependant from each other, are run and calibrated independently, therefore contributions between each module have to be determined. For the surface module, groundwater and runoff contributions have been determined by hydrograph separation. Among the automated base-flow separation methods, the one-parameter Chapman filter (Chapman et al 1999) has been chosen. This filter is a decomposition of the actual base-flow between the previous base-flow and the discharge gradient weighted by functions of the recession coefficient. For the groundwater module, the recharge has been determined from surface and sub-surface module. References : Flipo, N., A. Mourhi, B. Labarthe, and S. Biancamaria (2014). Continental hydrosystem modelling : the concept of nested stream-aquifer interfaces. Hydrol. Earth Syst. Sci. Discuss. 11, 451-500. Chapman,TG. (1999). A comparison of algorithms for stream flow recession and base-flow separation. hydrological Processes 13, 701-714.

  19. Definition of energy-calibrated spectra for national reachback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunz, Christopher L.; Hertz, Kristin L.

    2014-01-01

    Accurate energy calibration is critical for the timeliness and accuracy of analysis results of spectra submitted to National Reachback, particularly for the detection of threat items. Many spectra submitted for analysis include either a calibration spectrum using 137Cs or no calibration spectrum at all. The single line provided by 137Cs is insufficient to adequately calibrate nonlinear spectra. A calibration source that provides several lines that are well-spaced, from the low energy cutoff to the full energy range of the detector, is needed for a satisfactory energy calibration. This paper defines the requirements of an energy calibration for the purposes ofmore » National Reachback, outlines a method to validate whether a given spectrum meets that definition, discusses general source considerations, and provides a specific operating procedure for calibrating the GR-135.« less

  20. Chaos, Consternation and CALIPSO Calibration: New Strategies for Calibrating the CALIOP 1064 nm Channel

    NASA Technical Reports Server (NTRS)

    Vaughan, Mark; Garnier, Anne; Liu, Zhaoyan; Josset, Damien; Hu, Yongxiang; Lee, Kam-Pui; Hunt, William; Vernier, Jean-Paul; Rodier, Sharon; Pelon, Jaques; hide

    2012-01-01

    The very low signal-to-noise ratios of the 1064 nm CALIOP molecular backscatter signal make it effectively impossible to employ the "clear air" normalization technique typically used to calibrate elastic back-scatter lidars. The CALIPSO mission has thus chosen to cross-calibrate their 1064 nm measurements with respect to the 532 nm data using the two-wavelength backscatter from cirrus clouds. In this paper we discuss several known issues in the version 3 CALIOP 1064 nm calibration procedure, and describe the strategies that will be employed in the version 4 data release to surmount these problems.

  1. Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

    DOE PAGES

    Beresh, Steven J.; Wagner, Justin L.; Smith, Barton L.

    2016-03-16

    Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Furthermore, we our measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. In spite of the different answers obtained by varied self-calibrations, each implementation locked onto anmore » apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Thus, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.« less

  2. Spectra Transfer Between a Fourier Transform Near-Infrared Laboratory and a Miniaturized Handheld Near-Infrared Spectrometer.

    PubMed

    Hoffmann, Uwe; Pfeifer, Frank; Hsuing, Chang; Siesler, Heinz W

    2016-05-01

    The aim of this contribution is to demonstrate the transfer of spectra that have been measured on two different laboratory Fourier transform near-infrared (FT-NIR) spectrometers to the format of a handheld instrument by measuring only a few samples with both spectrometer types. Thus, despite the extreme differences in spectral range and resolution, spectral data sets that have been collected and quantitative as well as qualitative calibrations that have been developed thereof, respectively, over a long period on a laboratory instrument can be conveniently transferred to the handheld system. Thus, the necessity to prepare completely new calibration samples and the effort required to develop calibration models when changing hardware platforms is minimized. The enabling procedure is based on piecewise direct standardization (PDS) and will be described for the data sets of a quantitative and a qualitative application case study. For this purpose the spectra measured on the FT-NIR laboratory spectrometers were used as "master" data and transferred to the "target" format of the handheld instrument. The quantitative test study refers to transmission spectra of three-component liquid solvent mixtures whereas the qualitative application example encompasses diffuse reflection spectra of six different current polymers. To prove the performance of the transfer procedure for quantitative applications, partial least squares (PLS-1) calibrations were developed for the individual components of the solvent mixtures with spectra transferred from the master to the target instrument and the cross-validation parameters were compared with the corresponding parameters obtained for spectra measured on the master and target instruments, respectively. To test the retention of the discrimination ability of the transferred polymer spectra sets principal component analyses (PCAs) were applied exemplarily for three of the six investigated polymers and their identification was demonstrated by Mahalanobis distance plots for all polymers. © The Author(s) 2016.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, T; Graham, C L; Sundsmo, T

    This procedure provides instructions for the calibration and use of the Canberra iSolo Low Background Alpha/Beta Counting System (iSolo) that is used for counting air filters and swipe samples. This detector is capable of providing radioisotope identification (e.g., it can discriminate between radon daughters and plutonium). This procedure includes step-by-step instructions for: (1) Performing periodic or daily 'Background' and 'Efficiency QC' checks; (2) Setting-up the iSolo for counting swipes and air filters; (3) Counting swipes and air filters for alpha and beta activity; and (4) Annual calibration.

  4. Timing Calibration of the NEMO Optical Sensors

    NASA Astrophysics Data System (ADS)

    Circella, M.; de Marzo, C.; Megna, R.; Ruppi, M.

    2006-04-01

    This paper describes the timing calibration system for the NEMO underwater neutrino telescope. The NEMO Project aims at the construction of a km3 detector, equipped with a large number of photomultipliers, in the Mediterranean Sea. We foresee a redundant system to perform the time calibration of our apparatus: 1) A two-step procedure for measuring the offsets in the time measurements of the NEMO optical sensors, so as to measure separately the time delay for the synchronization signals to reach the offshore electronics and the response time of the photomultipliers to calibration signals delivered from optical pulsers through an optical fibre distribution system; 2) an all-optical procedure for measuring the differences in the time offsets of the different optical modules illuminated by calibration pulses. Such a system can be extended to work for a very large apparatus, even for complex arrangements of widely spaced sensors. The NEMO prototyping activities ongoing at a test site off the coast of Sicily will allow the system described in this work to be operated and tested in situ next year.

  5. Shape calibration of a conformal ultrasound therapy array.

    PubMed

    McGough, R J; Cindric, D; Samulski, T V

    2001-03-01

    A conformal ultrasound phased array prototype with 96 elements was recently calibrated for electronic steering and focusing in a water tank. The procedure for calibrating the shape of this 2D therapy array consists of two steps. First, a least squares triangulation algorithm determines the element coordinates from a 21 x 21 grid of time delays. The triangulation algorithm also requires temperature measurements to compensate for variations in the speed of sound. Second, a Rayleigh-Sommerfeld formulation of the acoustic radiation integral is aligned to a second grid of measured pressure amplitudes in a least squares sense. This shape calibration procedure, which is applicable to a wide variety of ultrasound phased arrays, was tested on a square array panel consisting of 7- x 7-mm elements operating at 617 kHz. The simulated fields generated by an array of 96 equivalent elements are consistent with the measured data, even in the fine structure away from the primary focus and sidelobes. These two calibration steps are sufficient for the simulation model to predict successfully the pressure field generated by this conformal ultrasound phased array prototype.

  6. The preliminary checkout, evaluation and calibration of a 3-component force measurement system for calibrating propulsion simulators for wind tunnel models

    NASA Technical Reports Server (NTRS)

    Scott, W. A.

    1984-01-01

    The propulsion simulator calibration laboratory (PSCL) in which calibrations can be performed to determine the gross thrust and airflow of propulsion simulators installed in wind tunnel models is described. The preliminary checkout, evaluation and calibration of the PSCL's 3 component force measurement system is reported. Methods and equipment were developed for the alignment and calibration of the force measurement system. The initial alignment of the system demonstrated the need for more efficient means of aligning system's components. The use of precision alignment jigs increases both the speed and accuracy with which the system is aligned. The calibration of the force measurement system shows that the methods and equipment for this procedure can be successful.

  7. A method of calibrating wind velocity sensors with a modified gas flow calibrator

    NASA Technical Reports Server (NTRS)

    Stump, H. P.

    1978-01-01

    A procedure was described for calibrating air velocity sensors in the exhaust flow of a gas flow calibrator. The average velocity in the test section located at the calibrator exhaust was verified from the mass flow rate accurately measured by the calibrator's precision sonic nozzles. Air at elevated pressures flowed through a series of screens, diameter changes, and flow straighteners, resulting in a smooth flow through the open test section. The modified system generated air velocities of 2 to 90 meters per second with an uncertainty of about two percent for speeds below 15 meters per second and four percent for the higher speeds. Wind tunnel data correlated well with that taken in the flow calibrator.

  8. Application of virtual distances methodology to laser tracker verification with an indexed metrology platform

    NASA Astrophysics Data System (ADS)

    Acero, R.; Santolaria, J.; Pueo, M.; Aguilar, J. J.; Brau, A.

    2015-11-01

    High-range measuring equipment like laser trackers need large dimension calibrated reference artifacts in their calibration and verification procedures. In this paper, a new verification procedure for portable coordinate measuring instruments based on the generation and evaluation of virtual distances with an indexed metrology platform is developed. This methodology enables the definition of an unlimited number of reference distances without materializing them in a physical gauge to be used as a reference. The generation of the virtual points and reference lengths derived is linked to the concept of the indexed metrology platform and the knowledge of the relative position and orientation of its upper and lower platforms with high accuracy. It is the measuring instrument together with the indexed metrology platform one that remains still, rotating the virtual mesh around them. As a first step, the virtual distances technique is applied to a laser tracker in this work. The experimental verification procedure of the laser tracker with virtual distances is simulated and further compared with the conventional verification procedure of the laser tracker with the indexed metrology platform. The results obtained in terms of volumetric performance of the laser tracker proved the suitability of the virtual distances methodology in calibration and verification procedures for portable coordinate measuring instruments, broadening and expanding the possibilities for the definition of reference distances in these procedures.

  9. Current profilers and current meters: compass and tilt sensors errors and calibration

    NASA Astrophysics Data System (ADS)

    Le Menn, M.; Lusven, A.; Bongiovanni, E.; Le Dû, P.; Rouxel, D.; Lucas, S.; Pacaud, L.

    2014-08-01

    Current profilers and current meters have a magnetic compass and tilt sensors for relating measurements to a terrestrial reference frame. As compasses are sensitive to their magnetic environment, they must be calibrated in the configuration in which they will be used. A calibration platform for magnetic compasses and tilt sensors was built, based on a method developed in 2007, to correct angular errors and guarantee a measurement uncertainty for instruments mounted in mooring cages. As mooring cages can weigh up to 800 kg, it was necessary to find a suitable place to set up this platform, map the magnetic fields in this area and dimension the platform to withstand these loads. It was calibrated using a GPS positioning technique. The platform has a table that can be tilted to calibrate the tilt sensors. The measurement uncertainty of the system was evaluated. Sinusoidal corrections based on the anomalies created by soft and hard magnetic materials were tested, as well as manufacturers’ calibration methods.

  10. Error analysis of speed of sound reconstruction in ultrasound limited angle transmission tomography.

    PubMed

    Jintamethasawat, Rungroj; Lee, Won-Mean; Carson, Paul L; Hooi, Fong Ming; Fowlkes, J Brian; Goodsitt, Mitchell M; Sampson, Richard; Wenisch, Thomas F; Wei, Siyuan; Zhou, Jian; Chakrabarti, Chaitali; Kripfgans, Oliver D

    2018-04-07

    We have investigated limited angle transmission tomography to estimate speed of sound (SOS) distributions for breast cancer detection. That requires both accurate delineations of major tissues, in this case by segmentation of prior B-mode images, and calibration of the relative positions of the opposed transducers. Experimental sensitivity evaluation of the reconstructions with respect to segmentation and calibration errors is difficult with our current system. Therefore, parametric studies of SOS errors in our bent-ray reconstructions were simulated. They included mis-segmentation of an object of interest or a nearby object, and miscalibration of relative transducer positions in 3D. Close correspondence of reconstruction accuracy was verified in the simplest case, a cylindrical object in homogeneous background with induced segmentation and calibration inaccuracies. Simulated mis-segmentation in object size and lateral location produced maximum SOS errors of 6.3% within 10 mm diameter change and 9.1% within 5 mm shift, respectively. Modest errors in assumed transducer separation produced the maximum SOS error from miscalibrations (57.3% within 5 mm shift), still, correction of this type of error can easily be achieved in the clinic. This study should aid in designing adequate transducer mounts and calibration procedures, and in specification of B-mode image quality and segmentation algorithms for limited angle transmission tomography relying on ray tracing algorithms. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A high-precision voltage source for EIT

    PubMed Central

    Saulnier, Gary J; Liu, Ning; Ross, Alexander S

    2006-01-01

    Electrical impedance tomography (EIT) utilizes electrodes placed on the surface of a body to determine the complex conductivity distribution within the body. EIT can be performed by applying currents through the electrodes and measuring the electrode voltages or by applying electrode voltages and measuring the currents. Techniques have also been developed for applying the desired currents using voltage sources. This paper describes a voltage source for use in applied-voltage EIT that includes the capability of measuring both the applied voltage and applied current. A calibration circuit and calibration algorithm are described which enables all voltage sources in an EIT system to be calibrated to a common standard. The calibration minimizes the impact of stray shunt impedance, passive component variability and active component non-ideality. Simulation data obtained using PSpice are used to demonstrate the effectiveness of the circuits and calibration algorithm. PMID:16636413

  12. Evaluation of platinum resistance thermometers

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Dillon-Townes, Lawrence A.

    1988-01-01

    An evaluation procedure for the characterization of industrial platinum resistance thermometers (PRTs) for use in the temperature range -120 to 160 C was investigated. This evaluation procedure consisted of calibration, thermal stability and hysteresis testing of four surface measuring PRTs. Five different calibration schemes were investigated for these sensors. The IPTS-68 formulation produced the most accurate result, yielding average sensor systematic error of 0.02 C and random error of 0.1 C. The sensors were checked for thermal stability by successive and thermal cycling between room temperature, 160 C, and boiling point of nitrogen. All the PRTs suffered from instability and hysteresis. The applicability of the self-heating technique as an in situ method for checking the calibration of PRTs located inside wind tunnels was investigated.

  13. The ISO SWS on-line system

    NASA Technical Reports Server (NTRS)

    Roelfsema, P. R.; Kester, D. J. M.; Wesselius, P. R.; Wieprech, E.; Sym, N.

    1992-01-01

    The software which is currently being developed for the Short Wavelength Spectrometer (SWS) of the Infrared Space Observatory (ISO) is described. The spectrometer has a wide range of capabilities in the 2-45 micron infrared band. SWS contains two independent gratings, one for the long and one for the short wavelength section of the band. With the gratings a spectral resolution of approximately 1000 to approximately 2500 can be obtained. The instrument also contains two Fabry-Perault's yielding a resolution between approximately 1000 and approximately 20000. Software is currently being developed for the acquisition, calibration, and analysis of SWS data. The software is firstly required to run in a pipeline mode without human interaction, to process data as they are received from the telescope. However, both for testing and calibration of the instrument as well as for evaluation of the planned operating procedures the software should also be suitable for interactive use. Thirdly the same software will be used for long term characterization of the instrument. The software must work properly within the environment designed by the European Space Agency (ESA) for the spacecraft operations. As a result strict constraints are put on I/O devices, throughput etc.

  14. Enhancing NDOT's Traffic Safety Programs

    DOT National Transportation Integrated Search

    2013-10-01

    This report summarizes three tasks of the UTC project. Firstly, the report presents the SPF calibration procedures and results for rural two-way two-lane roads. A calibration factor was found to be 1.21 for both total and Fatal and Injury crashes. In...

  15. Tracking system analytic calibration activities for the Mariner Mars 1971 mission

    NASA Technical Reports Server (NTRS)

    Madrid, G. A.; Chao, C. C.; Fliegel, H. F.; Leavitt, R. K.; Mottinger, N. A.; Winn, F. B.; Wimberly, R. N.; Yip, K. B.; Zielenbach, J. W.

    1974-01-01

    Data covering various planning aspects of Mariner Mars 1971 mission are summarized. Data cover calibrating procedures for tracking stations, radio signal propagation in the troposphere, effects of charged particles on radio transmission, orbit calculation, and data smoothing.

  16. Collection of Calibration and Validation Data for An Airport Landside Dynamic Simulation Model

    DOT National Transportation Integrated Search

    1980-04-01

    The report summarizes the airport data collection procedures employed to obtain the necessary calibration and validation information. The preparation for the data collection effort is explained. A description is presented of the initial work tasks, w...

  17. Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin

    Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibrationmore » service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These different methods of calibration demonstrated +1% to +2% differences in solar irradiance measurement. Analyzing these differences will ultimately help determine the uncertainty of the field radiometer data and guide the development of a consensus standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainty will allow more accurate prediction of solar output and improve the bankability of solar projects.« less

  18. Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dongsu; Cox, Sam J.; Cho, Heejin

    With increased use of variable refrigerant flow (VRF) systems in the U.S. building sector, interests in capability and rationality of various building energy modeling tools to simulate VRF systems are rising. This paper presents the detailed procedures for model calibration of a VRF system with a dedicated outdoor air system (DOAS) by comparing to detailed measured data from an occupancy emulated small office building. The building energy model is first developed based on as-built drawings, and building and system characteristics available. The whole building energy modeling tool used for the study is U.S. DOE’s EnergyPlus version 8.1. The initial modelmore » is, then, calibrated with the hourly measured data from the target building and VRF-DOAS system. In a detailed calibration procedures of the VRF-DOAS, the original EnergyPlus source code is modified to enable the modeling of the specific VRF-DOAS installed in the building. After a proper calibration during cooling and heating seasons, the VRF-DOAS model can reasonably predict the performance of the actual VRF-DOAS system based on the criteria from ASHRAE Guideline 14-2014. The calibration results show that hourly CV-RMSE and NMBE would be 15.7% and 3.8%, respectively, which is deemed to be calibrated. As a result, the whole-building energy usage after calibration of the VRF-DOAS model is 1.9% (78.8 kWh) lower than that of the measurements during comparison period.« less

  19. Radiometric responsivity determination for Feature Identification and Location Experiment (FILE) flown on space shuttle mission

    NASA Technical Reports Server (NTRS)

    Wilson, R. G.; Davis, R. E.; Wright, R. E., Jr.; Sivertson, W. E., Jr.; Bullock, G. F.

    1986-01-01

    A procedure was developed to obtain the radiometric (radiance) responsivity of the Feature Identification and Local Experiment (FILE) instrument in preparation for its flight on Space Shuttle Mission 41-G (November 1984). This instrument was designed to obtain Earth feature radiance data in spectral bands centered at 0.65 and 0.85 microns, along with corroborative color and color-infrared photographs, and to collect data to evaluate a technique for in-orbit autonomous classification of the Earth's primary features. The calibration process incorporated both solar radiance measurements and radiative transfer model predictions in estimating expected radiance inputs to the FILE on the Shuttle. The measured data are compared with the model predictions, and the differences observed are discussed. Application of the calibration procedure to the FILE over an 18-month period indicated a constant responsivity characteristic. This report documents the calibration procedure and the associated radiometric measurements and predictions that were part of the instrument preparation for flight.

  20. Development of a drift-correction procedure for a direct-reading spectrometer

    NASA Technical Reports Server (NTRS)

    Chapman, G. B., II; Gordon, W. A.

    1977-01-01

    A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

  1. A Single-Vector Force Calibration Method Featuring the Modern Design of Experiments

    NASA Technical Reports Server (NTRS)

    Parker, P. A.; Morton, M.; Draper, N.; Line, W.

    2001-01-01

    This paper proposes a new concept in force balance calibration. An overview of the state-of-the-art in force balance calibration is provided with emphasis on both the load application system and the experimental design philosophy. Limitations of current systems are detailed in the areas of data quality and productivity. A unique calibration loading system integrated with formal experimental design techniques has been developed and designated as the Single-Vector Balance Calibration System (SVS). This new concept addresses the limitations of current systems. The development of a quadratic and cubic calibration design is presented. Results from experimental testing are compared and contrasted with conventional calibration systems. Analyses of data are provided that demonstrate the feasibility of this concept and provide new insights into balance calibration.

  2. Comparison of spectral radiance responsivity calibration techniques used for backscatter ultraviolet satellite instruments

    NASA Astrophysics Data System (ADS)

    Kowalewski, M. G.; Janz, S. J.

    2015-02-01

    Methods of absolute radiometric calibration of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration uncertainties. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV, Total Ozone Mapping Spectrometer, Ozone Mapping Instrument, and Global Ozone Monitoring Experiment 2 using standardized procedures traceable to national standards. These sphere-based spectral responsivities agree to within the derived combined standard uncertainty of 1.87% relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary spectral radiance responsivity calibration method for BUV instruments. The combined standard uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Center’s Radiometric Calibration and Development Laboratory is shown to less than 2% at 250 nm when using a single traceable calibration standard.

  3. Generic System for Remote Testing and Calibration of Measuring Instruments: Security Architecture

    NASA Astrophysics Data System (ADS)

    Jurčević, M.; Hegeduš, H.; Golub, M.

    2010-01-01

    Testing and calibration of laboratory instruments and reference standards is a routine activity and is a resource and time consuming process. Since many of the modern instruments include some communication interfaces, it is possible to create a remote calibration system. This approach addresses a wide range of possible applications and permits to drive a number of different devices. On the other hand, remote calibration process involves a number of security issues due to recommendations specified in standard ISO/IEC 17025, since it is not under total control of the calibration laboratory personnel who will sign the calibration certificate. This approach implies that the traceability and integrity of the calibration process directly depends on the collected measurement data. The reliable and secure remote control and monitoring of instruments is a crucial aspect of internet-enabled calibration procedure.

  4. Quantitative X-ray Map Analyser (Q-XRMA): A new GIS-based statistical approach to Mineral Image Analysis

    NASA Astrophysics Data System (ADS)

    Ortolano, Gaetano; Visalli, Roberto; Godard, Gaston; Cirrincione, Rosolino

    2018-06-01

    We present a new ArcGIS®-based tool developed in the Python programming language for calibrating EDS/WDS X-ray element maps, with the aim of acquiring quantitative information of petrological interest. The calibration procedure is based on a multiple linear regression technique that takes into account interdependence among elements and is constrained by the stoichiometry of minerals. The procedure requires an appropriate number of spot analyses for use as internal standards and provides several test indexes for a rapid check of calibration accuracy. The code is based on an earlier image-processing tool designed primarily for classifying minerals in X-ray element maps; the original Python code has now been enhanced to yield calibrated maps of mineral end-members or the chemical parameters of each classified mineral. The semi-automated procedure can be used to extract a dataset that is automatically stored within queryable tables. As a case study, the software was applied to an amphibolite-facies garnet-bearing micaschist. The calibrated images obtained for both anhydrous (i.e., garnet and plagioclase) and hydrous (i.e., biotite) phases show a good fit with corresponding electron microprobe analyses. This new GIS-based tool package can thus find useful application in petrology and materials science research. Moreover, the huge quantity of data extracted opens new opportunities for the development of a thin-section microchemical database that, using a GIS platform, can be linked with other major global geoscience databases.

  5. International Round-Robin Testing of Bulk Thermoelectrics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hsin; Porter, Wallace D; Bottner, Harold

    2011-11-01

    Two international round-robin studies were conducted on transport properties measurements of bulk thermoelectric materials. The study discovered current measurement problems. In order to get ZT of a material four separate transport measurements must be taken. The round-robin study showed that among the four properties Seebeck coefficient is the one can be measured consistently. Electrical resistivity has +4-9% scatter. Thermal diffusivity has similar +5-10% scatter. The reliability of the above three properties can be improved by standardizing test procedures and enforcing system calibrations. The worst problem was found in specific heat measurements using DSC. The probability of making measurement error ismore » great due to the fact three separate runs must be taken to determine Cp and the baseline shift is always an issue for commercial DSC. It is suggest the Dulong Petit limit be always used as a guide line for Cp. Procedures have been developed to eliminate operator and system errors. The IEA-AMT annex is developing standard procedures for transport properties testing.« less

  6. Contactless measurement of alternating current conductance in quantum Hall structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drichko, I. L.; Diakonov, A. M.; Malysh, V. A.

    2014-10-21

    We report a procedure to determine the frequency-dependent conductance of quantum Hall structures in a broad frequency domain. The procedure is based on the combination of two known probeless methods—acoustic spectroscopy and microwave spectroscopy. By using the acoustic spectroscopy, we study the low-frequency attenuation and phase shift of a surface acoustic wave in a piezoelectric crystal in the vicinity of the electron (hole) layer. The electronic contribution is resolved using its dependence on a transverse magnetic field. At high frequencies, we study the attenuation of an electromagnetic wave in a coplanar waveguide. To quantitatively calibrate these data, we use themore » fact that in the quantum-Hall-effect regime the conductance at the maxima of its magnetic field dependence is determined by extended states. Therefore, it should be frequency independent in a broad frequency domain. The procedure is verified by studies of a well-characterized p-SiGe/Ge/SiGe heterostructure.« less

  7. Design and Mechanical Evaluation of a Capacitive Sensor-Based Indexed Platform for Verification of Portable Coordinate Measuring Instruments

    PubMed Central

    Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar

    2014-01-01

    During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures. PMID:24451458

  8. Design and mechanical evaluation of a capacitive sensor-based indexed platform for verification of portable coordinate measuring instruments.

    PubMed

    Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar

    2014-01-02

    During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures.

  9. Performance analysis of a film dosimetric quality assurance procedure for IMRT with regard to the employment of quantitative evaluation methods.

    PubMed

    Winkler, Peter; Zurl, Brigitte; Guss, Helmuth; Kindl, Peter; Stuecklschweiger, Georg

    2005-02-21

    A system for dosimetric verification of intensity-modulated radiotherapy (IMRT) treatment plans using absolute calibrated radiographic films is presented. At our institution this verification procedure is performed for all IMRT treatment plans prior to patient irradiation. Therefore clinical treatment plans are transferred to a phantom and recalculated. Composite treatment plans are irradiated to a single film. Film density to absolute dose conversion is performed automatically based on a single calibration film. A software application encompassing film calibration, 2D registration of measurement and calculated distributions, image fusion, and a number of visual and quantitative evaluation utilities was developed. The main topic of this paper is a performance analysis for this quality assurance procedure, with regard to the specification of tolerance levels for quantitative evaluations. Spatial and dosimetric precision and accuracy were determined for the entire procedure, comprising all possible sources of error. The overall dosimetric and spatial measurement uncertainties obtained thereby were 1.9% and 0.8 mm respectively. Based on these results, we specified 5% dose difference and 3 mm distance-to-agreement as our tolerance levels for patient-specific quality assurance for IMRT treatments.

  10. Data Processing for Atmospheric Phase Interferometers

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J.; Nessel, James A.; Morabito, David D.

    2009-01-01

    This paper presents a detailed discussion of calibration procedures used to analyze data recorded from a two-element atmospheric phase interferometer (API) deployed at Goldstone, California. In addition, we describe the data products derived from those measurements that can be used for site intercomparison and atmospheric modeling. Simulated data is used to demonstrate the effectiveness of the proposed algorithm and as a means for validating our procedure. A study of the effect of block size filtering is presented to justify our process for isolating atmospheric fluctuation phenomena from other system-induced effects (e.g., satellite motion, thermal drift). A simulated 24 hr interferometer phase data time series is analyzed to illustrate the step-by-step calibration procedure and desired data products.

  11. NREL Improves Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2012-01-01

    This technical highlight describes NREL research to develop Building Energy Simulation Test for Existing Homes (BESTEST-EX) to increase the quality and accuracy of energy analysis tools for the building retrofit market. Researchers at the National Renewable Energy Laboratory (NREL) have developed a new test procedure to increase the quality and accuracy of energy analysis tools for the building retrofit market. The Building Energy Simulation Test for Existing Homes (BESTEST-EX) is a test procedure that enables software developers to evaluate the performance of their audit tools in modeling energy use and savings in existing homes when utility bills are available formore » model calibration. Similar to NREL's previous energy analysis tests, such as HERS BESTEST and other BESTEST suites included in ANSI/ASHRAE Standard 140, BESTEST-EX compares software simulation findings to reference results generated with state-of-the-art simulation tools such as EnergyPlus, SUNREL, and DOE-2.1E. The BESTEST-EX methodology: (1) Tests software predictions of retrofit energy savings in existing homes; (2) Ensures building physics calculations and utility bill calibration procedures perform to a minimum standard; and (3) Quantifies impacts of uncertainties in input audit data and occupant behavior. BESTEST-EX includes building physics and utility bill calibration test cases. The diagram illustrates the utility bill calibration test cases. Participants are given input ranges and synthetic utility bills. Software tools use the utility bills to calibrate key model inputs and predict energy savings for the retrofit cases. Participant energy savings predictions using calibrated models are compared to NREL predictions using state-of-the-art building energy simulation programs.« less

  12. Accounting for temporal variation in soil hydrological properties when simulating surface runoff on tilled plots

    NASA Astrophysics Data System (ADS)

    Chahinian, Nanée; Moussa, Roger; Andrieux, Patrick; Voltz, Marc

    2006-07-01

    Tillage operations are known to greatly influence local overland flow, infiltration and depressional storage by altering soil hydraulic properties and soil surface roughness. The calibration of runoff models for tilled fields is not identical to that of untilled fields, as it has to take into consideration the temporal variability of parameters due to the transient nature of surface crusts. In this paper, we seek the application of a rainfall-runoff model and the development of a calibration methodology to take into account the impact of tillage on overland flow simulation at the scale of a tilled plot (3240 m 2) located in southern France. The selected model couples the (Morel-Seytoux, H.J., 1978. Derivation of equations for variable rainfall infiltration. Water Resources Research. 14(4), 561-568). Infiltration equation to a transfer function based on the diffusive wave equation. The parameters to be calibrated are the hydraulic conductivity at natural saturation Ks, the surface detention Sd and the lag time ω. A two-step calibration procedure is presented. First, eleven rainfall-runoff events are calibrated individually and the variability of the calibrated parameters are analysed. The individually calibrated Ks values decrease monotonously according to the total amount of rainfall since tillage. No clear relationship is observed between the two parameters Sd and ω, and the date of tillage. However, the lag time ω increases inversely with the peakflow of the events. Fairly good agreement is observed between the simulated and measured hydrographs of the calibration set. Simple mathematical laws describing the evolution of Ks and ω are selected, while Sd is considered constant. The second step involves the collective calibration of the law of evolution of each parameter on the whole calibration set. This procedure is calibrated on 11 events and validated on ten runoff inducing and four non-runoff inducing rainfall events. The suggested calibration methodology seems robust and can be transposed to other gauged sites.

  13. Determination of $sup 241$Am in soil using an automated nuclear radiation measurement laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engstrom, D.E.; White, M.G.; Dunaway, P.B.

    The recent completion of REECo's Automated Laboratory and associated software systems has provided a significant increase in capability while reducing manpower requirements. The system is designed to perform gamma spectrum analyses on the large numbers of samples required by the current Nevada Applied Ecology Group (NAEG) and Plutonium Distribution Inventory Program (PDIP) soil sampling programs while maintaining sufficient sensitivities as defined by earlier investigations of the same type. The hardware and systems are generally described in this paper, with emphasis being placed on spectrum reduction and the calibration procedures used for soil samples. (auth)

  14. Plume Measurement System (PLUMES) Calibration Experiment

    DTIC Science & Technology

    1994-08-01

    calibration chamber was lished and documented. To apply acoustic designed and built Particles were suspended technology to monitoring suspended sedi- in the...procedures are described in Chap- ter 2. Repeatability of the experiments and validity of the results are de - scribed in Chapter 3. In Chapter 4, the range...went into their design . The first two subsections give an overview of the calibration chamber and its characteristics. The remaining subsections describe

  15. Design and calibration of a scanning tunneling microscope for large machined surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigg, D.A.; Russell, P.E.; Dow, T.A.

    During the last year the large sample STM has been designed, built and used for the observation of several different samples. Calibration of the scanner for prope dimensional interpretation of surface features has been a chief concern, as well as corrections for non-linear effects such as hysteresis during scans. Several procedures used in calibration and correction of piezoelectric scanners used in the laboratorys STMs are described.

  16. Thematic mapper flight model preshipment review data package. Volume 3, part B: System data

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Procedures and results are presented for performance and systems integration tests of flight model-1 thematic mapper. Aspects considered cover electronic module integration, radiometric calibration, spectral matching, spatial coverage, radiometric calibration of the calibrator, coherent noise, dynamic square wave response, band to band registration, geometric accuracy, and self induced vibration. Thermal vacuum tests, EMI/EMS, and mass properties are included. Liens are summarized.

  17. The photomultiplier tube calibration system of the MicroBooNE experiment

    DOE PAGES

    Conrad, J.; Jones, B. J. P.; Moss, Z.; ...

    2015-06-03

    Here, we report on the design and construction of a LED-based fiber calibration system for large liquid argon time projection detectors. This system was developed to calibrate the optical systems of the MicroBooNE experiment. As well as detailing the materials and installation procedure, we provide technical drawings and specifications so that the system may be easily replicated in future LArTPC detectors.

  18. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    NASA Astrophysics Data System (ADS)

    Chatzidimitriou-Dreismann, C. A.; Gray, E. MacA.; Blach, T. P.

    2012-06-01

    The "standard" procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the "standard" calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D2 in the backscattering angular range (θ>90°) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the "standard" calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present "standard" calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H2 molecules. For Case (B), some suggestions as to how the "standard" calibration could be considerably improved are made.

  19. 40 CFR 160.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (b) The written standard operating procedures required under § 160.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  20. 40 CFR 160.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (b) The written standard operating procedures required under § 160.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  1. 40 CFR 160.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (b) The written standard operating procedures required under § 160.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  2. 40 CFR 160.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (b) The written standard operating procedures required under § 160.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  3. 40 CFR 160.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (b) The written standard operating procedures required under § 160.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  4. 40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...

  5. TNT Prout-Tompkins Kinetics Calibration with PSUADE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wemhoff, A P; Hsieh, H

    2007-04-11

    We used the code PSUADE to calibrate Prout-Tompkins kinetic parameters for pure recrystallized TNT. The calibration was based on ALE3D simulations of a series of One Dimensional Time to Explosion (ODTX) experiments. The resultant kinetic parameters differed from TNT data points with an average error of 28%, which is slightly higher than the value of 23% previously calculated using a two-point optimization. The methodology described here provides a basis for future calibration studies using PSUADE. The files used in the procedure are listed in the Appendix.

  6. NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration Procedure and Results

    NASA Technical Reports Server (NTRS)

    Van Zante, Judith F.; Ide, Robert F.; Steen, Laura E.; Acosta, Waldo J.

    2014-01-01

    The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are presented. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C ('typical' icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

  7. Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

    NASA Technical Reports Server (NTRS)

    Jelinsky, P.; Jelinsky, S. R.; Miller, A.; Vallerga, J.; Malina, R. F.

    1988-01-01

    The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

  8. 40 CFR 86.221-94 - Hydrocarbon analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Hydrocarbon analyzer calibration. 86.221-94 Section 86.221-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.221-94 Hydrocarbon analyzer...

  9. 40 CFR 86.221-94 - Hydrocarbon analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Hydrocarbon analyzer calibration. 86.221-94 Section 86.221-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.221-94 Hydrocarbon analyzer...

  10. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it

    2016-06-28

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behaviormore » if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.« less

  11. Indirect check of the stability of the reference ion chamber used for accelerator output calibration

    NASA Astrophysics Data System (ADS)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Park, Soah; Hwang, Taejin; Cheong, Kwang-Ho; Han, Tae Jin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Bae, Hoonsik

    2014-11-01

    A linear accelerator's output is periodically checked by using a reference ion chamber which is also periodically calibrated at the accredited standard dosimetry laboratories. We suggest a simple procedure for checking the chamber's stability between calibrations by comparison with another ion chamber. To identify the long-term stability of chambers, we collected and assessed the dose-to-water conversion factors provided by standard laboratories for three chambers during a period of four years. To develop the chamber constancy check program, we used one Farmer-type reference ion chamber FC65-G, two ion chambers (CC13a and CC13b) and one CC01 ion chamber (IBA). Under the accelerator, each chamber was placed inside the solid phantom and irradiated; the experimental configurations were identical. To check the variation in charge collection of the reference chamber, we monitored the ratios of the FC65-G values over each chamber reading. Based on the error propagation of the two chamber ratios, we estimated the uncertainty of the output calibration from the chamber variation. The calibration factors provided for the three chambers showed 0.04 ˜ 0.12% standard deviations during four years. For procedure development, the reading ratios of FC65-G over CCxx showed very good stability; the ratios of FC65-G over CC13a, CC13b and CC01 varied less than 0.059, 0.087 and 0.248%, respectively, over five measurements. By ascribing possible uncertainties of the ratio to the reference chamber alone, we could conservatively check the stability of the reference chamber for treatment safety. An extension of the chamber calibration period was also evaluated. In conclusion, we designed a stability check procedure for the reference chamber based on a reading ratio of two chambers. This could help the user assess the chamber stability between periodic chamber calibration, and the associated patient treatment could be carried out with enhanced safety.

  12. Monitoring scanner calibration using the image-derived arterial blood SUV in whole-body FDG-PET.

    PubMed

    Maus, Jens; Hofheinz, Frank; Apostolova, Ivayla; Kreissl, Michael C; Kotzerke, Jörg; van den Hoff, Jörg

    2018-05-15

    The current de facto standard for quantification of tumor metabolism in oncological whole-body PET is the standardized uptake value (SUV) approach. SUV determination requires accurate scanner calibration. Residual inaccuracies of the calibration lead to biased SUV values. Especially, this can adversely affect multicenter trials where it is difficult to ensure reliable cross-calibration across participating sites. The goal of the present work was the evaluation of a new method for monitoring scanner calibration utilizing the image-derived arterial blood SUV (BSUV) averaged over a sufficiently large number of whole-body FDG-PET investigations. Data of 681 patients from three sites which underwent routine 18 F-FDG PET/CT or PET/MR were retrospectively analyzed. BSUV was determined in the descending aorta using a three-dimensional ROI concentric to the aorta's centerline. The ROI was delineated in the CT or MRI images and transferred to the PET images. A minimum ROI volume of 5 mL and a concentric safety margin to the aortic wall was observed. Mean BSUV, standard deviation (SD), and standard error of the mean (SE) were computed for three groups of patients at each site, investigated 2 years apart, respectively, with group sizes between 53 and 100 patients. Differences of mean BSUV between the individual groups and sites were determined. SD (SE) of BSUV in the different groups ranged from 14.3 to 20.7% (1.7 to 2.8%). Differences of mean BSUV between intra-site groups were small (1.1-6.3%). Only one out of nine of these differences reached statistical significance. Inter-site differences were distinctly larger (12.6-25.1%) and highly significant (P<0.001). Image-based determination of the group-averaged blood SUV in modestly large groups of whole-body FDG-PET investigations is a viable approach for ensuring consistent scanner calibration over time and across different sites. We propose this approach as a quality control and cross-calibration tool augmenting established phantom-based procedures.

  13. A graphical method to evaluate spectral preprocessing in multivariate regression calibrations: example with Savitzky-Golay filters and partial least squares regression.

    PubMed

    Delwiche, Stephen R; Reeves, James B

    2010-01-01

    In multivariate regression analysis of spectroscopy data, spectral preprocessing is often performed to reduce unwanted background information (offsets, sloped baselines) or accentuate absorption features in intrinsically overlapping bands. These procedures, also known as pretreatments, are commonly smoothing operations or derivatives. While such operations are often useful in reducing the number of latent variables of the actual decomposition and lowering residual error, they also run the risk of misleading the practitioner into accepting calibration equations that are poorly adapted to samples outside of the calibration. The current study developed a graphical method to examine this effect on partial least squares (PLS) regression calibrations of near-infrared (NIR) reflection spectra of ground wheat meal with two analytes, protein content and sodium dodecyl sulfate sedimentation (SDS) volume (an indicator of the quantity of the gluten proteins that contribute to strong doughs). These two properties were chosen because of their differing abilities to be modeled by NIR spectroscopy: excellent for protein content, fair for SDS sedimentation volume. To further demonstrate the potential pitfalls of preprocessing, an artificial component, a randomly generated value, was included in PLS regression trials. Savitzky-Golay (digital filter) smoothing, first-derivative, and second-derivative preprocess functions (5 to 25 centrally symmetric convolution points, derived from quadratic polynomials) were applied to PLS calibrations of 1 to 15 factors. The results demonstrated the danger of an over reliance on preprocessing when (1) the number of samples used in a multivariate calibration is low (<50), (2) the spectral response of the analyte is weak, and (3) the goodness of the calibration is based on the coefficient of determination (R(2)) rather than a term based on residual error. The graphical method has application to the evaluation of other preprocess functions and various types of spectroscopy data.

  14. PSF mapping-based correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging.

    PubMed

    In, Myung-Ho; Posnansky, Oleg; Speck, Oliver

    2016-05-01

    To accurately correct diffusion-encoding direction-dependent eddy-current-induced geometric distortions in diffusion-weighted echo-planar imaging (DW-EPI) and to minimize the calibration time at 7 Tesla (T). A point spread function (PSF) mapping based eddy-current calibration method is newly presented to determine eddy-current-induced geometric distortions even including nonlinear eddy-current effects within the readout acquisition window. To evaluate the temporal stability of eddy-current maps, calibration was performed four times within 3 months. Furthermore, spatial variations of measured eddy-current maps versus their linear superposition were investigated to enable correction in DW-EPIs with arbitrary diffusion directions without direct calibration. For comparison, an image-based eddy-current correction method was additionally applied. Finally, this method was combined with a PSF-based susceptibility-induced distortion correction approach proposed previously to correct both susceptibility and eddy-current-induced distortions in DW-EPIs. Very fast eddy-current calibration in a three-dimensional volume is possible with the proposed method. The measured eddy-current maps are very stable over time and very similar maps can be obtained by linear superposition of principal-axes eddy-current maps. High resolution in vivo brain results demonstrate that the proposed method allows more efficient eddy-current correction than the image-based method. The combination of both PSF-based approaches allows distortion-free images, which permit reliable analysis in diffusion tensor imaging applications at 7T. © 2015 Wiley Periodicals, Inc.

  15. Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography

    PubMed Central

    Szkulmowski, Maciej; Tamborski, Szymon; Wojtkowski, Maciej

    2016-01-01

    We propose a simple and robust procedure for Fourier domain optical coherence tomography (FdOCT) that allows to linearize the detected FdOCT spectra to wavenumber domain and, at the same time, to determine the wavelength of light for each point of detected spectrum. We show that in this approach it is possible to use any measurable physical quantity that has linear dependency on wavenumber and can be extracted from spectral fringes. The actual values of the measured quantity have no importance for the algorithm and do not need to be known at any stage of the procedure. As example we calibrate a spectral OCT spectrometer using Doppler frequency. The technique of spectral calibration can be in principle adapted to of all kind of Fourier domain OCT devices. PMID:28018723

  16. Discordance between net analyte signal theory and practical multivariate calibration.

    PubMed

    Brown, Christopher D

    2004-08-01

    Lorber's concept of net analyte signal is reviewed in the context of classical and inverse least-squares approaches to multivariate calibration. It is shown that, in the presence of device measurement error, the classical and inverse calibration procedures have radically different theoretical prediction objectives, and the assertion that the popular inverse least-squares procedures (including partial least squares, principal components regression) approximate Lorber's net analyte signal vector in the limit is disproved. Exact theoretical expressions for the prediction error bias, variance, and mean-squared error are given under general measurement error conditions, which reinforce the very discrepant behavior between these two predictive approaches, and Lorber's net analyte signal theory. Implications for multivariate figures of merit and numerous recently proposed preprocessing treatments involving orthogonal projections are also discussed.

  17. SERPent: Automated reduction and RFI-mitigation software for e-MERLIN

    NASA Astrophysics Data System (ADS)

    Peck, Luke W.; Fenech, Danielle M.

    2013-08-01

    The Scripted E-merlin Rfi-mitigation PipelinE for iNTerferometry (SERPent) is an automated reduction and RFI-mitigation procedure utilising the SumThreshold methodology (Offringa et al., 2010a), originally developed for the LOFAR pipeline. SERPent is written in the Parseltongue language enabling interaction with the Astronomical Image Processing Software (AIPS) program. Moreover, SERPent is a simple 'out of the box' Python script, which is easy to set up and is free of compilers. In addition to the flagging of RFI affected visibilities, the script also flags antenna zero-amplitude dropouts and Lovell telescope phase calibrator stationary scans inherent to the e-MERLIN system. Both the flagging and computational performances of SERPent are presented here, for e-MERLIN commissioning datasets for both L-band (1.3-1.8 GHz) and C-band (4-8 GHz) observations. RFI typically amounts to <20%-25% for the more problematic L-band observations and <5% for the generally RFI quieter C-band. The level of RFI detection and flagging is more accurate and delicate than visual manual flagging, with the output immediately ready for AIPS calibration. SERPent is fully parallelised and has been tested on a range of computing systems. The current flagging rate is at 110 GB day-1 on a 'high-end' computer (16 CPUs, 100 GB memory) which amounts to ˜6.9 GB CPU-1 day-1, with an expected increase in performance when e-MERLIN has completed its commissioning. The refining of automated reduction and calibration procedures is essential for the e-MERLIN legacy projects and future interferometers such as the SKA and the associated pathfinders (MeerKAT and ASKAP), where the vast data sizes (>TB) make traditional astronomer interactions unfeasible.

  18. Multiplexed fluctuation-dissipation-theorem calibration of optical tweezers inside living cells

    NASA Astrophysics Data System (ADS)

    Yan, Hao; Johnston, Jessica F.; Cahn, Sidney B.; King, Megan C.; Mochrie, Simon G. J.

    2017-11-01

    In order to apply optical tweezers-based force measurements within an uncharacterized viscoelastic medium such as the cytoplasm of a living cell, a quantitative calibration method that may be applied in this complex environment is needed. We describe an improved version of the fluctuation-dissipation-theorem calibration method, which has been developed to perform in situ calibration in viscoelastic media without prior knowledge of the trapped object. Using this calibration procedure, it is possible to extract values of the medium's viscoelastic moduli as well as the force constant describing the optical trap. To demonstrate our method, we calibrate an optical trap in water, in polyethylene oxide solutions of different concentrations, and inside living fission yeast (S. pombe).

  19. Calibration and Measurement Uncertainty Estimation of Radiometric Data: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Sengupta, M.; Reda, I.

    2014-11-01

    Evaluating the performance of photovoltaic cells, modules, and arrays that form large solar deployments relies on accurate measurements of the available solar resource. Therefore, determining the accuracy of these solar radiation measurements provides a better understanding of investment risks. This paper provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements by radiometers using methods that follow the International Bureau of Weights and Measures Guide to the Expression of Uncertainty (GUM). Standardized analysis based on these procedures ensures that the uncertainty quoted is well documented.

  20. Construction of a Cr3C2-C Peritectic Point Cell for Thermocouple Calibration

    NASA Astrophysics Data System (ADS)

    Ogura, Hideki; Deuze, Thierry; Morice, Ronan; Ridoux, Pascal; Filtz, Jean-Remy

    The melting points of Cr3C2-C peritectic (1826°C) and Cr7C3-Cr3C2 eutectic (1742°C) alloys as materials for high-temperature fixed point cells are investigated for the use of thermocouple calibration. Pretests are performed to establish a suitable procedure for constructing contact thermometry cells based on such chromium-carbon mixtures. Two cells are constructed following two different possible procedures. The above two melting points are successfully observed for one of these cells using tungsten-rhenium alloy thermocouples.

  1. Airborne hygrometer calibration inter-comparison against a metrological water vapour standard

    NASA Astrophysics Data System (ADS)

    Smorgon, Denis; Boese, Norbert; Ebert, Volker

    2014-05-01

    Water vapour is the most important atmospheric greenhouse gas, which causes a major feedback to warming and other changes in the climate system. Knowledge of the distribution of water vapour and its climate induced changes is especially important in the upper troposphere and lower stratosphere (UT/LS) where vapour plays a critical role in atmospheric radiative balance, cirrus cloud formation, and photochemistry. But, our understanding of water in the UT/LS is limited by significant uncertainties in current UT/LS water measurements. One of the most comprehensive inter-comparison campaigns for airborne hygrometers, termed AQUAVIT (AV1) [1], took place in 2007 at the AIDA chamber at the Karlsruhe Institute of Technology (KIT) in Germany. AV1 was a well-defined, referred, blind inter-comparison of 22 airborne field instruments from 17 international research groups. One major metrological deficit of AV1, however, was, that no traceable reference instrument participated in the inter-comparison experiments and that the calibration procedures of the participating instruments were not monitored or interrogated. Consequently a follow-up inter-comparison was organized in April 2013, which for the first time also provides a traceable link to the international humidity scale. This AQUAVIT2 (AV2) campaign (details see: http://www.imk-aaf.kit.edu/aquavit/index.php/Main_Page) was again located at KIT/AIDA and organised by an international organizing committee including KIT, PTB, FZJ and others. Generally AV2 is divided in two parallel comparisons: 1) AV2-A uses the AIDA chamber for a simultaneous comparison of all instruments (incl. sampling and in-situ instruments) over a broad range of conditions characteristic for the UT/LS; 2) AV2-B, about which this paper is reporting, is a sequential comparison of selected hygrometers and (when possible) their reference calibration infrastructures by means of a chilled mirror hygrometer traced back to the primary National humidity standard of PTB and a validated, two-pressure generator acting as a highly stable and reproducible source of water vapour. The aim of AV2-B was to perform an absolute, metrological comparison of the field instruments/calibration infrastructures to the metrological humidity scale, and to collect essential information about methods and procedures used by the atmospheric community for instrument calibration and validation, in order to investigate e.g. the necessity and possible comparability advantage by a standardized calibration procedure. The work will give an overview over the concept of the AV2-B inter-comparison, the various general measurement and calibration principles, and discuss the outcome and consequences of the comparison effort. The AQUAVIT effort is linked to the EMRP project METEOMET (ENV07) and partially supported by the EMRP and ENV07. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. [1] H. Saathoff, C. Schiller, V. Ebert, D. W. Fahey, R.-S. Gao, O. Möhler, and the aquavit team, The AQUAVIT formal intercomparison of atmospheric water measurement methods, 5th General Assembly of the European Geosciences Union, 13-18 April 2008, Vienna, Austria Keywords: humidity, water vapour, inter-comparison, airborne instruments.

  2. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  3. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  4. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  5. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  6. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  7. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  8. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  9. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  10. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  11. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  12. Accurate calibration of a molecular beam time-of-flight mass spectrometer for on-line analysis of high molecular weight species.

    PubMed

    Apicella, B; Wang, X; Passaro, M; Ciajolo, A; Russo, C

    2016-10-15

    Time-of-Flight (TOF) Mass Spectrometry is a powerful analytical technique, provided that an accurate calibration by standard molecules in the same m/z range of the analytes is performed. Calibration in a very large m/z range is a difficult task, particularly in studies focusing on the detection of high molecular weight clusters of different molecules or high molecular weight species. External calibration is the most common procedure used for TOF mass spectrometric analysis in the gas phase and, generally, the only available standards are made up of mixtures of noble gases, covering a small mass range for calibration, up to m/z 136 (higher mass isotope of xenon). In this work, an accurate calibration of a Molecular Beam Time-of Flight Mass Spectrometer (MB-TOFMS) is presented, based on the use of water clusters up to m/z 3000. The advantages of calibrating a MB-TOFMS with water clusters for the detection of analytes with masses above those of the traditional calibrants such as noble gases were quantitatively shown by statistical calculations. A comparison of the water cluster and noble gases calibration procedures in attributing the masses to a test mixture extending up to m/z 800 is also reported. In the case of the analysis of combustion products, another important feature of water cluster calibration was shown, that is the possibility of using them as "internal standard" directly formed from the combustion water, under suitable experimental conditions. The water clusters calibration of a MB-TOFMS gives rise to a ten-fold reduction in error compared to the traditional calibration with noble gases. The consequent improvement in mass accuracy in the calibration of a MB-TOFMS has important implications in various fields where detection of high molecular mass species is required. In combustion products analysis, it is also possible to obtain a new calibration spectrum before the acquisition of each spectrum, only modifying some operative conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. GEOS-C noncoherent C-band transponder test procedure for spacecraft level tests

    NASA Technical Reports Server (NTRS)

    Selser, A. R.

    1973-01-01

    Test procedures necessary for the calibration and performance verification of the noncoherent C-band transponders after spacecraft hardware integration, but prior to spacecraft/launch vehicle integration are presented.

  14. Quality control and assurance for validation of DOS/I measurements

    NASA Astrophysics Data System (ADS)

    Cerussi, Albert; Durkin, Amanda; Kwong, Richard; Quang, Timothy; Hill, Brian; Tromberg, Bruce J.; MacKinnon, Nick; Mantulin, William W.

    2010-02-01

    Ongoing multi-center clinical trials are crucial for Biophotonics to gain acceptance in medical imaging. In these trials, quality control (QC) and assurance (QA) are key to success and provide "data insurance". Quality control and assurance deal with standardization, validation, and compliance of procedures, materials and instrumentation. Specifically, QC/QA involves systematic assessment of testing materials, instrumentation performance, standard operating procedures, data logging, analysis, and reporting. QC and QA are important for FDA accreditation and acceptance by the clinical community. Our Biophotonics research in the Network for Translational Research in Optical Imaging (NTROI) program for breast cancer characterization focuses on QA/QC issues primarily related to the broadband Diffuse Optical Spectroscopy and Imaging (DOS/I) instrumentation, because this is an emerging technology with limited standardized QC/QA in place. In the multi-center trial environment, we implement QA/QC procedures: 1. Standardize and validate calibration standards and procedures. (DOS/I technology requires both frequency domain and spectral calibration procedures using tissue simulating phantoms and reflectance standards, respectively.) 2. Standardize and validate data acquisition, processing and visualization (optimize instrument software-EZDOS; centralize data processing) 3. Monitor, catalog and maintain instrument performance (document performance; modularize maintenance; integrate new technology) 4. Standardize and coordinate trial data entry (from individual sites) into centralized database 5. Monitor, audit and communicate all research procedures (database, teleconferences, training sessions) between participants ensuring "calibration". This manuscript describes our ongoing efforts, successes and challenges implementing these strategies.

  15. Development of procedures for programmable proximity aperture lithography

    NASA Astrophysics Data System (ADS)

    Whitlow, H. J.; Gorelick, S.; Puttaraksa, N.; Napari, M.; Hokkanen, M. J.; Norarat, R.

    2013-07-01

    Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyväskylä and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeatability of the translator end-point switches. Another area of consideration has been the fluence control procedures. These involve control of the uniformity of the beam where different approaches for fluence measurement such as simultaneous aperture current and the ion current passing through the aperture using a Faraday cup are used. Microfluidic patterns may contain many elements that make-up mixing sections, reaction chambers, separation columns and fluid reservoirs. To facilitate conception and planning we have implemented a .svg file interpreter, that allows the use of scalable vector graphics files produced by standard drawing software for generation of patterns made up of rectangular elements.

  16. Standardization of the capillary electrophoresis procedures Capillarys® CDT and Minicap® CDT in comparison to the IFCC reference measurement procedure.

    PubMed

    Schellenberg, François; Humeau, Camille

    2017-06-01

    CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.

  17. Multiresidue determination of pesticides in crop plants by the quick, easy, cheap, effective, rugged, and safe method and ultra-high-performance liquid chromatography tandem mass spectrometry using a calibration based on a single level standard addition in the sample.

    PubMed

    Viera, Mariela S; Rizzetti, Tiele M; de Souza, Maiara P; Martins, Manoel L; Prestes, Osmar D; Adaime, Martha B; Zanella, Renato

    2017-12-01

    In this study, a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method, optimized by a 2 3 full factorial design, was developed for the determination of 72 pesticides in plant parts of carrot, corn, melon, rice, soy, silage, tobacco, cassava, lettuce and wheat by ultra-high-performance liquid chromatographic tandem mass spectrometry (UHPLC-MS/MS). Considering the complexity of these matrices and the need of use calibration in matrix, a new calibration approach based on single level standard addition in the sample (SLSAS) was proposed in this work and compared with the matrix-matched calibration (MMC), the procedural standard calibration (PSC) and the diluted standard addition calibration (DSAC). All approaches presented satisfactory validation parameters with recoveries from 70 to 120% and relative standard deviations≤20%. SLSAS was the most practical from the evaluated approaches and proved to be an effective way of calibration. Method limit of detection were between 4.8 and 48μgkg -1 and limit of quantification were from 16 to 160μgkg -1 . Method application to different kinds of plants found residues of 20 pesticides that were quantified with z-scores values≤2 in comparison with other calibration approaches. The proposed QuEChERS method combined with UHPLC-MS/MS analysis and using an easy and effective calibration procedure presented satisfactory results for pesticide residues determination in different crop plants and is a good alternative for routine analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. In-process, non-destructive, dynamic testing of high-speed polymer composite rotors

    NASA Astrophysics Data System (ADS)

    Kuschmierz, Robert; Filippatos, Angelos; Günther, Philipp; Langkamp, Albert; Hufenbach, Werner; Czarske, Jürgen; Fischer, Andreas

    2015-03-01

    Polymer composite rotors are lightweight and offer great perspectives in high-speed applications such as turbo machinery. Currently, novel rotor structures and materials are investigated for the purpose of increasing machine efficiency and lifetime, as well as allowing for higher dynamic loads. However, due to the complexity of the composite materials an in-process measurement system is required. This allows for monitoring the evolution of damages under dynamic loads, for testing and predicting the structural integrity of composite rotors in process. In rotor design, it can be used for calibrating and improving models, simulating the dynamic behaviour of polymer composite rotors. The measurement system is to work non-invasive, offer micron uncertainty, as well as a high measurement rate of several tens of kHz. Furthermore, it must be applicable at high surface speeds and under technical vacuum. In order to fulfil these demands a novel laser distance measurement system was developed. It provides the angle resolved measurement of the biaxial deformation of a fibre-reinforced polymer composite rotor with micron uncertainty at surface speeds of more than 300 m/s. Furthermore, a simulation procedure combining a finite element model and a damage mechanics model is applied. A comparison of the measured data and the numerically calculated data is performed to validate the simulation towards rotor expansion. This validating procedure can be used for a model calibration in the future. The simulation procedure could be used to investigate different damage-test cases of the rotor, in order to define its structural behaviour without further experiments.

  19. 40 CFR 86.224-94 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Carbon dioxide analyzer calibration. 86.224-94 Section 86.224-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.224-94 Carbon dioxide...

  20. 40 CFR 57.404 - Measurements, records, and reports.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and record at least one measurement of sulfur dioxide concentration and stack gas flow rate from the... manufacturer's recommended zero adjustment and calibration procedures at least once per 24-hour operating... which clearly show instrument readings before and after zero adjustment and calibration. (5) The results...

  1. 40 CFR 86.218-94 - Dynamometer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.218-94 Dynamometer calibration. The...

  2. 40 CFR 86.224-94 - Carbon dioxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon dioxide analyzer calibration... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.224-94 Carbon dioxide...

  3. 40 CFR 86.222-94 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide analyzer calibration... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.222-94 Carbon monoxide...

  4. 40 CFR Appendix I to Subparts D... - Motorcycle Noise Emission Test Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... calibrated with the acoustic calibrator as often as is necessary throughout testing to maintain the accuracy... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Motorcycle Noise Emission Test... AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycle...

  5. 40 CFR Appendix I to Subparts D... - Motorcycle Noise Emission Test Procedures

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... calibrated with the acoustic calibrator as often as is necessary throughout testing to maintain the accuracy... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Motorcycle Noise Emission Test... AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycle...

  6. Temperature compensated and self-calibrated current sensor using reference current

    DOEpatents

    Yakymyshyn, Christopher Paul [Seminole, FL; Brubaker, Michael Allen [Loveland, CO; Yakymyshyn, Pamela Jane [Seminole, FL

    2008-01-22

    A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference electrical current carried by a conductor positioned within the sensing window of the current sensor is used to correct variations in the output signal due to temperature variations and aging.

  7. An integrated approach to monitoring the calibration stability of operational dual-polarization radars

    DOE PAGES

    Vaccarono, Mattia; Bechini, Renzo; Chandrasekar, Chandra V.; ...

    2016-11-08

    The stability of weather radar calibration is a mandatory aspect for quantitative applications, such as rainfall estimation, short-term weather prediction and initialization of numerical atmospheric and hydrological models. Over the years, calibration monitoring techniques based on external sources have been developed, specifically calibration using the Sun and calibration based on ground clutter returns. In this paper, these two techniques are integrated and complemented with a self-consistency procedure and an intercalibration technique. The aim of the integrated approach is to implement a robust method for online monitoring, able to detect significant changes in the radar calibration. The physical consistency of polarimetricmore » radar observables is exploited using the self-consistency approach, based on the expected correspondence between dual-polarization power and phase measurements in rain. This technique allows a reference absolute value to be provided for the radar calibration, from which eventual deviations may be detected using the other procedures. In particular, the ground clutter calibration is implemented on both polarization channels (horizontal and vertical) for each radar scan, allowing the polarimetric variables to be monitored and hardware failures to promptly be recognized. The Sun calibration allows monitoring the calibration and sensitivity of the radar receiver, in addition to the antenna pointing accuracy. It is applied using observations collected during the standard operational scans but requires long integration times (several days) in order to accumulate a sufficient amount of useful data. Finally, an intercalibration technique is developed and performed to compare colocated measurements collected in rain by two radars in overlapping regions. The integrated approach is performed on the C-band weather radar network in northwestern Italy, during July–October 2014. The set of methods considered appears suitable to establish an online tool to monitor the stability of the radar calibration with an accuracy of about 2 dB. In conclusion, this is considered adequate to automatically detect any unexpected change in the radar system requiring further data analysis or on-site measurements.« less

  8. Astronomical Polarimetry with the RIT Polarization Imaging Camera

    NASA Astrophysics Data System (ADS)

    Vorobiev, Dmitry V.; Ninkov, Zoran; Brock, Neal

    2018-06-01

    In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device performance in the lab, by determining the relative throughput, efficiency, and orientation of every pixel, as a function of wavelength. Using the resulting pixel response model, we developed demodulation procedures for aperture photometry and imaging polarimetry observing modes. We found that, using the current calibration, RITPIC is capable of detecting polarization signals as small as ∼0.3%. The relative ease of data collection, calibration, and analysis provided by these sensors suggest than they may become an important tool for a number of astronomical targets.

  9. Conditional Versus Unconditional Procedures for Sample-Free Item Analysis

    ERIC Educational Resources Information Center

    Wright, Benjamin D.; Douglas, Graham A.

    1977-01-01

    Procedures for the Rasch model, sample free item calibration are reviewed and compared for accuracy. The theoretically ideal procedure is shown to have practical limitations. Two alternatives to the ideal are presented and discussed. A correction for bias in the most widely used alternative is presented. (Author/JKS)

  10. In-Situ Transfer Standard and Coincident-View Intercomparisons for Sensor Cross-Calibration

    NASA Technical Reports Server (NTRS)

    Thome, Kurt; McCorkel, Joel; Czapla-Myers, Jeff

    2013-01-01

    There exist numerous methods for accomplishing on-orbit calibration. Methods include the reflectance-based approach relying on measurements of surface and atmospheric properties at the time of a sensor overpass as well as invariant scene approaches relying on knowledge of the temporal characteristics of the site. The current work examines typical cross-calibration methods and discusses the expected uncertainties of the methods. Data from the Advanced Land Imager (ALI), Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER), Enhanced Thematic Mapper Plus (ETM+), Moderate Resolution Imaging Spectroradiometer (MODIS), and Thematic Mapper (TM) are used to demonstrate the limits of relative sensor-to-sensor calibration as applied to current sensors while Landsat-5 TM and Landsat-7 ETM+ are used to evaluate the limits of in situ site characterizations for SI-traceable cross calibration. The current work examines the difficulties in trending of results from cross-calibration approaches taking into account sampling issues, site-to-site variability, and accuracy of the method. Special attention is given to the differences caused in the cross-comparison of sensors in radiance space as opposed to reflectance space. The results show that cross calibrations with absolute uncertainties lesser than 1.5 percent (1 sigma) are currently achievable even for sensors without coincident views.

  11. Web-based assessments of physical activity in youth: considerations for design and scale calibration.

    PubMed

    Saint-Maurice, Pedro F; Welk, Gregory J

    2014-12-01

    This paper describes the design and methods involved in calibrating a Web-based self-report instrument to estimate physical activity behavior. The limitations of self-report measures are well known, but calibration methods enable the reported information to be equated to estimates obtained from objective data. This paper summarizes design considerations for effective development and calibration of physical activity self-report measures. Each of the design considerations is put into context and followed by a practical application based on our ongoing calibration research with a promising online self-report tool called the Youth Activity Profile (YAP). We first describe the overall concept of calibration and how this influences the selection of appropriate self-report tools for this population. We point out the advantages and disadvantages of different monitoring devices since the choice of the criterion measure and the strategies used to minimize error in the measure can dramatically improve the quality of the data. We summarize strategies to ensure quality control in data collection and discuss analytical considerations involved in group- vs individual-level inference. For cross-validation procedures, we describe the advantages of equivalence testing procedures that directly test and quantify agreement. Lastly, we introduce the unique challenges encountered when transitioning from paper to a Web-based tool. The Web offers considerable potential for broad adoption but an iterative calibration approach focused on continued refinement is needed to ensure that estimates are generalizable across individuals, regions, seasons and countries.

  12. Improvements in Calibration and Analysis of the CTBT-relevant Radioxenon Isotopes with High Resolution SiPIN-based Electron Detectors

    NASA Astrophysics Data System (ADS)

    Khrustalev, K.

    2016-12-01

    Current process for the calibration of the beta-gamma detectors used for radioxenon isotope measurements for CTBT purposes is laborious and time consuming. It uses a combination of point sources and gaseous sources resulting in differences between energy and resolution calibrations. The emergence of high resolution SiPIN based electron detectors allows improvements in the calibration and analysis process to be made. Thanks to high electron resolution of SiPIN detectors ( 8-9 keV@129 keV) compared to plastic scintillators ( 35 keV@129keV) there are a lot more CE peaks (from radioxenon and radon progenies) can be resolved and used for energy and resolution calibration in the energy range of the CTBT-relevant radioxenon isotopes. The long term stability of the SiPIN energy calibration allows one to significantly reduce the time of the QC measurements needed for checking the stability of the E/R calibration. The currently used second order polynomials for the E/R calibration fitting are unphysical and shall be replaced by a linear energy calibration for NaI and SiPIN, owing to high linearity and dynamic range of the modern digital DAQ systems, and resolution calibration functions shall be modified to reflect the underlying physical processes. Alternatively, one can completely abandon the use of fitting functions and use only point-values of E/R (similar to the efficiency calibration currently used) at the energies relevant for the isotopes of interest (ROI - Regions Of Interest ). Current analysis considers the detector as a set of single channel analysers, with an established set of coefficients relating the positions of ROIs with the positions of the QC peaks. The analysis of the spectra can be made more robust using peak and background fitting in the ROIs with a single free parameter (peak area) of the potential peaks from the known isotopes and a fixed E/R calibration values set.

  13. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  14. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  15. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  16. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  17. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  18. Increasing the sensitivity of the Jaffe reaction for creatinine

    NASA Technical Reports Server (NTRS)

    Tom, H. Y.

    1973-01-01

    Study of analytical procedure has revealed that linearity of creatinine calibration curve can be extended by using 0.03 molar picric acid solution made up in 70 percent ethanol instead of water. Three to five times more creatinine concentration can be encompassed within linear portion of calibration curve.

  19. Method and apparatus of a portable imaging-based measurement with self calibration

    DOEpatents

    Chang, Tzyy-Shuh [Ann Arbor, MI; Huang, Hsun-Hau [Ann Arbor, MI

    2012-07-31

    A portable imaging-based measurement device is developed to perform 2D projection based measurements on an object that is difficult or dangerous to access. This device is equipped with self calibration capability and built-in operating procedures to ensure proper imaging based measurement.

  20. 40 CFR 86.118-00 - Dynamometer calibrations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles and New Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.118-00 Dynamometer calibrations. (a) The dynamometer shall be...