Sample records for current diagnostic systems

  1. Microfluidics-Enabled Diagnostic Systems: Markets, Challenges, and Examples.

    PubMed

    Becker, Holger; Gärtner, Claudia

    2017-01-01

    Microfluidics has become an important tool for the commercial product development in diagnostics. This article will focus on current technical demands during the development process such as material and integration challenges. Furthermore, we present data on the diagnostics market as well as examples of microfluidics-enabled systems currently under commercial development or already on the market.

  2. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    PubMed

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  3. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  4. Measurements of high-current electron beams from X pinches and wire array Z pinches.

    PubMed

    Shelkovenko, T A; Pikuz, S A; Blesener, I C; McBride, R D; Bell, K S; Hammer, D A; Agafonov, A V; Romanova, V M; Mingaleev, A R

    2008-10-01

    Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

  5. Electric Fuel Pump Condition Monitor System Using Electricalsignature Analysis

    DOEpatents

    Haynes, Howard D [Knoxville, TN; Cox, Daryl F [Knoxville, TN; Welch, Donald E [Oak Ridge, TN

    2005-09-13

    A pump diagnostic system and method comprising current sensing probes clamped on electrical motor leads of a pump for sensing only current signals on incoming motor power, a signal processor having a means for buffering and anti-aliasing current signals into a pump motor current signal, and a computer having a means for analyzing, displaying, and reporting motor current signatures from the motor current signal to determine pump health using integrated motor and pump diagnostic parameters.

  6. About increasing informativity of diagnostic system of asynchronous electric motor by extracting additional information from values of consumed current parameter

    NASA Astrophysics Data System (ADS)

    Zhukovskiy, Y.; Korolev, N.; Koteleva, N.

    2018-05-01

    This article is devoted to expanding the possibilities of assessing the technical state of the current consumption of asynchronous electric drives, as well as increasing the information capacity of diagnostic methods, in conditions of limited access to equipment and incompleteness of information. The method of spectral analysis of the electric drive current can be supplemented by an analysis of the components of the current of the Park's vector. The research of the hodograph evolution in the moment of appearance and development of defects was carried out using the example of current asymmetry in the phases of an induction motor. The result of the study is the new diagnostic parameters of the asynchronous electric drive. During the research, it was proved that the proposed diagnostic parameters allow determining the type and level of the defect. At the same time, there is no need to stop the equipment and taky it out of service for repair. Modern digital control and monitoring systems can use the proposed parameters based on the stator current of an electrical machine to improve the accuracy and reliability of obtaining diagnostic patterns and predicting their changes in order to improve the equipment maintenance systems. This approach can also be used in systems and objects where there are significant parasitic vibrations and unsteady loads. The extraction of useful information can be carried out in electric drive systems in the structure of which there is a power electric converter.

  7. When Less Is More: How Fewer Diagnostic Criteria Can Indicate Greater Severity

    ERIC Educational Resources Information Center

    Cooper, Luke D.; Balsis, Steve

    2009-01-01

    For diagnosing many mental disorders, the current "Diagnostic and Statistical Manual of Mental Disorders" ("DSM") system weights each diagnostic criterion equally--each criterion counts the same toward meeting the diagnostic threshold. Research on the diagnostic efficiency of criteria, however, reveals that some diagnostic criteria are more useful…

  8. DSM-5, ICD-10, ICD-11, the Psychodynamic Diagnostic Manual, and Person-Centered Integrative Diagnosis: An Overview for College Mental Health Therapists

    ERIC Educational Resources Information Center

    Cooper, Stewart E.

    2014-01-01

    Therapists in the field of college mental health counseling commonly voice an ambivalent orientation towards the utilization of formal psychological diagnostic systems yet often use diagnostic terms. Knowledge of the current and emerging diagnostic systems may contribute to greater syntheses of these differing approaches. This article will first…

  9. Diagnostic Tools for Performance Evaluation of Innovative In-Situ Remediation Technologies at Chlorinated Solvent-Contaminated Sites

    DTIC Science & Technology

    2011-07-01

    to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT...these innovative methods with conventional diagnostic tools that are currently used for assessing bioremediation performance. 132 Rula Deeb (510) 596...conventional diagnostic tools that are currently used for assessing bioremediation performance. DEMONSTRATION RESULTS 3-D multi-level systems

  10. CHANGING OUR DIAGNOSTIC PARADIGM: MOVEMENT SYSTEM DIAGNOSTIC CLASSIFICATION

    PubMed Central

    Kamonseki, Danilo H.; Staker, Justin L.; Lawrence, Rebekah L.; Braman, Jonathan P.

    2017-01-01

    Proper diagnosis is a first step in applying best available treatments, and prognosticating outcomes for clients. Currently, the majority of musculoskeletal diagnoses are classified according to pathoanatomy. However, the majority of physical therapy treatments are applied toward movement system impairments or pain. While advocated within the physical therapy profession for over thirty years, diagnostic classification within a movement system framework has not been uniformly developed or adopted. We propose a basic framework and rationale for application of a movement system diagnostic classification for atraumatic shoulder pain conditions, as a case for the broader development of movement system diagnostic labels. Shifting our diagnostic paradigm has potential to enhance communication, improve educational efficiency, facilitate research, directly link to function, improve clinical care, and accelerate preventive interventions. PMID:29158950

  11. Embedding CLIPS in a database-oriented diagnostic system

    NASA Technical Reports Server (NTRS)

    Conway, Tim

    1990-01-01

    This paper describes the integration of C Language Production Systems (CLIPS) into a powerful portable maintenance aid (PMA) system used for flightline diagnostics. The current diagnostic target of the system is the Garrett GTCP85-180L, a gas turbine engine used as an Auxiliary Power Unit (APU) on some C-130 military transport aircraft. This project is a database oriented approach to a generic diagnostic system. CLIPS is used for 'many-to-many' pattern matching within the diagnostics process. Patterns are stored in database format, and CLIPS code is generated by a 'compilation' process on the database. Multiple CLIPS rule sets and working memories (in sequence) are supported and communication between the rule sets is achieved via the export and import commands. Work is continuing on using CLIPS in other portions of the diagnostic system and in re-implementing the diagnostic system in the Ada language.

  12. Gear Damage Detection Integrating Oil Debris and Vibration Measurement Technologies Developed

    NASA Technical Reports Server (NTRS)

    Gyekeyeski, Andrew L.; Sawicki, Jerzy T.

    2001-01-01

    The development of highly reliable health-monitoring systems is one technology area recommended for reducing the number of helicopter accidents. Helicopter transmission diagnostics are an important part of a helicopter health-monitoring system because helicopters depend on the power train for propulsion, lift, and flight maneuvering. One technique currently being tested for increasing the reliability and decreasing the false alarm rate of current transmission diagnostic tools is the replacement of simple single-sensor limits with multisensor systems integrating different measurement technologies.

  13. Overcoming limitations of model-based diagnostic reasoning systems

    NASA Technical Reports Server (NTRS)

    Holtzblatt, Lester J.; Marcotte, Richard A.; Piazza, Richard L.

    1989-01-01

    The development of a model-based diagnostic system to overcome the limitations of model-based reasoning systems is discussed. It is noted that model-based reasoning techniques can be used to analyze the failure behavior and diagnosability of system and circuit designs as part of the system process itself. One goal of current research is the development of a diagnostic algorithm which can reason efficiently about large numbers of diagnostic suspects and can handle both combinational and sequential circuits. A second goal is to address the model-creation problem by developing an approach for using design models to construct the GMODS model in an automated fashion.

  14. Where Lies the Fault in Diagnosing Dhat Syndrome among Females? Understanding through a Case Study.

    PubMed

    Kar, Sujita Kumar; Singh, Amit

    2017-01-01

    Dhat syndrome is a culture-bound syndrome of South-East Asia, common in young men. However, similar entity has also been described in female patients who attribute their symptoms to nonpathological or physiological vaginal discharge. The current diagnostic system for psychiatric illnesses does not encompass Dhat syndrome in females, and so these group of patients receive alternative diagnoses such as somatoform disorder or depression. As a result of which the focus of unique Dhat syndrome-centered management gets weakened, affecting the clinical outcome. This case study focuses on the diagnostic dilemmas related to Dhat syndrome in females and pitfalls in the current diagnostic system.

  15. 2D imaging X-ray diagnostic for measuring the current density distribution in a wide-area electron beam produced in a multiaperture diode with plasma cathode

    NASA Astrophysics Data System (ADS)

    Kurkuchekov, V.; Kandaurov, I.; Trunev, Y.

    2018-05-01

    A simple and inexpensive X-ray diagnostic tool was designed for measuring the cross-sectional current density distribution in a low-relativistic pulsed electron beam produced in a source based on an arc-discharge plasma cathode and multiaperture diode-type electron optical system. The beam parameters were as follows: Uacc = 50–110 kV, Ibeam = 20–100 A, τbeam = 0.1–0.3 ms. The beam effective diameter was ca. 7 cm. Based on a pinhole camera, the diagnostic allows one to obtain a 2D profile of electron beam flux distribution on a flat metal target in a single shot. The linearity of the diagnostic system response to the electron flux density was established experimentally. Spatial resolution of the diagnostic was also estimated in special test experiments. The optimal choice of the main components of the diagnostic technique is discussed.

  16. Phenomenology of Schizophrenia and the Representativeness of Modern Diagnostic Criteria.

    PubMed

    Kendler, Kenneth S

    2016-10-01

    This article aims to determine the degree to which modern operationalized diagnostic criteria for schizophrenia reflect the main clinical features of the disorder as described historically by diagnostic experts. Amazon.com, the National Library of Medicine, and Forgottenbooks.com were searched for articles written or translated into English from 1900 to 1960. Clinical descriptions of schizophrenia or dementia praecox appearing in 16 textbooks or review articles published between 1899 and 1956 were reviewed and compared with the criteria for schizophrenia from 6 modern US operationalized diagnostic systems. Twenty prominent symptoms and signs were reported by 5 or more authors. A strong association was seen between the frequency with which the symptoms/signs were reported and the likelihood of their presence in modern diagnostic systems. Of these 20 symptoms/signs, 3 (thought disorder, delusions, and hallucinations) were included in all diagnostic systems and were among the 4 most frequently reported. Three symptoms/signs were added then kept in subsequent criteria: emotional blunting, changes in volition, and changes in social life. Three symptoms/signs were added but then dropped: bizarre delusions, passivity symptoms, and mood incongruity. Eleven symptoms/signs were never included in any diagnostic system. Compared with historical authors, modern criteria favored symptoms over signs. Odd movements and postures, noted by 16 of 18 historical authors, were absent from all modern criteria. DSM-5 criteria contain 6 of the 20 historically noted symptoms/signs. Although modern operationalized criteria for schizophrenia reflect symptoms and signs commonly reported by historical experts, many clinical features emphasized by these experts are absent from modern criteria. This is not necessarily problematic as diagnostic criteria are meant to index rather than thoroughly describe syndromes. However, the lack of correspondence in schizophrenia between historically important symptoms/signs and current diagnostic systems highlights the limitations of clinical evaluations and research studies that restrict the diagnostic assessments to current diagnostic criteria. We should not confuse our DSM diagnostic criteria with the disorders that they were designed to index.

  17. The development of a post-test diagnostic system for rocket engines

    NASA Technical Reports Server (NTRS)

    Zakrajsek, June F.

    1991-01-01

    An effort was undertaken by NASA to develop an automated post-test, post-flight diagnostic system for rocket engines. The automated system is designed to be generic and to automate the rocket engine data review process. A modular, distributed architecture with a generic software core was chosen to meet the design requirements. The diagnostic system is initially being applied to the Space Shuttle Main Engine data review process. The system modules currently under development are the session/message manager, and portions of the applications section, the component analysis section, and the intelligent knowledge server. An overview is presented of a rocket engine data review process, the design requirements and guidelines, the architecture and modules, and the projected benefits of the automated diagnostic system.

  18. Development of life prediction capabilities for liquid propellant rocket engines. Post-fire diagnostic system for the SSME system architecture study

    NASA Technical Reports Server (NTRS)

    Gage, Mark; Dehoff, Ronald

    1991-01-01

    This system architecture task (1) analyzed the current process used to make an assessment of engine and component health after each test or flight firing of an SSME, (2) developed an approach and a specific set of objectives and requirements for automated diagnostics during post fire health assessment, and (3) listed and described the software applications required to implement this system. The diagnostic system described is a distributed system with a database management system to store diagnostic information and test data, a CAE package for visual data analysis and preparation of plots of hot-fire data, a set of procedural applications for routine anomaly detection, and an expert system for the advanced anomaly detection and evaluation.

  19. Schizoaffective disorder--an ongoing challenge for psychiatric nosology.

    PubMed

    Jäger, M; Haack, S; Becker, T; Frasch, K

    2011-04-01

    Schizoaffective disorder is a common diagnosis in mental health services. The present article aims to provide an overview of diagnostic reliability, symptomatology, outcome, neurobiology and treatment of schizoaffective disorder. Literature was identified by searches in "Medline" and "Cochrane Library". The diagnosis of schizoaffective disorder has a low reliability. There are marked differences between the current diagnostic systems. With respect to psychopathological symptoms, no clear boundaries were found between schizophrenia, schizoaffective disorder and affective disorders. Common neurobiological factors were found across the traditional diagnostic categories. Schizoaffective disorder according to ICD-10 criteria, but not to DSM-IV criteria, shows a more favorable outcome than schizophrenia. With regard to treatment, only a small and heterogeneous database exists. Due to the low reliability and questionable validity there is a substantial need for revision and unification of the current diagnostic concepts of schizoaffective disorder. If future diagnostic systems return to Kraepelin's dichotomous classification of non-organic psychosis or adopt a dimensional diagnostic approach, schizoaffective disorder will disappear from the psychiatric nomenclature. A nosological model with multiple diagnostic entities, however, would be compatible with retaining the diagnostic category of schizoaffective disorder. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  20. Molecular diagnostics of inflammatory disease: New tools and perspectives.

    PubMed

    Garzorz-Stark, Natalie; Lauffer, Felix

    2017-08-01

    This essay reviews current approaches to establish novel molecular diagnostic tools for inflammatory skin diseases. Moreover, it highlights the importance of stratifying patients according to molecular signatures and revising current outdated disease classification systems to eventually reach the goal of personalized medicine. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. [Theoretical grounds of a structural and functional model for quality assurance of radiation diagnostics under conditions of development of the modern health care system in Ukraine].

    PubMed

    Korop, Oleg A; Lenskykh, Sergiy V

    2018-01-01

    Introduction: Modern changes in the health care system of Ukraine are focused on financial support in providing medical and diagnostic care to the population and are based on deep and consistent structural and functional transformations. They are aimed at providing adequate quality care, which is the main target function and a principal criterion for operation of health care system. The urgency of this problem is increasing in the context of reforming the health care system and global changes in the governmental financial guarantees for the provision of medical services to the population. The aim of the work is to provide theoretical grounds for a structural and functional model of quality assurance of radiation diagnostics at all levels of medical care given to the population under the current health care reform in Ukraine. Materials and methods: The object of the study is organizing the operation of the radiation diagnostic service; the information is based on the actual data on the characteristics of radiation diagnosis at different levels of medical care provision. Methods of systematic approach, system analysis and structural and functional analysis of the operating system of radiation diagnostics are used. Review: The basis of the quality assurance model is the cyclical process, which includes the stages of the problem identifition, planning of its solution, organization of the system for implementation of decisions, monitoring the quality management process of the radiation diagnostics, and factors influencing the quality of the radiation diagnostics service. These factors include the quality of the structure, process, results, organization of management and control of current processes and the results of radiation diagnostics management. Conclusions: The advantages of the proposed model for ensuring the quality of the radiation diagnostics service are its systemacy and complexity, elimination of identified defects and deficiencies, and achievement of profitability through modern redistribution and use of existing resources of the health care system. The results of adequate service quality management activities in radiation diagnostics are the improvement of organizational and economic principles along with legislative regulation, the implementation of a modern system of radiation diagnostics in the state health care at the national and regional levels, the increase of the accessibility, quality and efficiency of the radiation diagnostics service.

  2. Use of the focusing multi-slit ion optical system at RUssian Diagnostic Injector (RUDI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Listopad, A.; Davydenko, V.; Ivanov, A.

    2012-02-15

    The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35 deg. Additionally, the plasma generator was modified to extend the beam pulsemore » to 8 s.« less

  3. The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

    NASA Technical Reports Server (NTRS)

    Ricks, Brian W.; Mengshoel, Ole J.

    2009-01-01

    Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

  4. Electrically heated particulate filter diagnostic systems and methods

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2009-09-29

    A system that diagnoses regeneration of an electrically heated particulate filter is provided. The system generally includes a grid module that diagnoses a fault of the grid based on at least one of a current signal and a voltage signal. A diagnostic module at least one of sets a fault status and generates a warning signal based on the fault of the grid.

  5. Developmental trauma disorder: pros and cons of including formal criteria in the psychiatric diagnostic systems

    PubMed Central

    2013-01-01

    Background This article reviews the current debate on developmental trauma disorder (DTD) with respect to formalizing its diagnostic criteria. Victims of abuse, neglect, and maltreatment in childhood often develop a wide range of age-dependent psychopathologies with various mental comorbidities. The supporters of a formal DTD diagnosis argue that post-traumatic stress disorder (PTSD) does not cover all consequences of severe and complex traumatization in childhood. Discussion Traumatized individuals are difficult to treat, but clinical experience has shown that they tend to benefit from specific trauma therapy. A main argument against inclusion of formal DTD criteria into existing diagnostic systems is that emphasis on the etiology of the disorder might force current diagnostic systems to deviate from their purely descriptive nature. Furthermore, comorbidities and biological aspects of the disorder may be underdiagnosed using the DTD criteria. Summary Here, we discuss arguments for and against the proposal of DTD criteria and address implications and consequences for the clinical practice. PMID:23286319

  6. A modern diagnostic approach for automobile systems condition monitoring

    NASA Astrophysics Data System (ADS)

    Selig, M.; Shi, Z.; Ball, A.; Schmidt, K.

    2012-05-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  7. Paranoid Schizophrenia: Assessing the Validity of the Diagnostic Schemata.

    ERIC Educational Resources Information Center

    Dobbs, James Mark

    This paper is concerned with changes which have been proposed in the major current diagnostic system regarding paranoid schizophrenia. It is noted that the proposed changes to the Diagnostic and Statistical Manual of Mental Disorders, Third Edition (DSM-III) would remove paranoia as a schizophrenic subtype and institute a spectrum description of…

  8. An overview of beam diagnostic and control systems for 50 MeV AREAL Linac

    NASA Astrophysics Data System (ADS)

    Sargsyan, A. A.; Amatuni, G. A.; Sahakyan, V. V.; Zanyan, G. S.; Martirosyan, N. W.; Vardanyan, V. V.; Grigoryan, B. A.

    2017-03-01

    Advanced Research Electron Accelerator Laboratory (AREAL) is an electron linear accelerator project with a laser driven RF gun being constructed at CANDLE Synchrotron Research Institute. After the successful operation of the gun section at 5 MeV, a program of facility energy enhancement up to 50 MeV is launched. In this paper the current status of existing diagnostic and control systems, as well as the results of electron beam parameter measurements are presented. The approaches of intended diagnostic and control systems for the upgrade program are also described.

  9. Fusion programs in applied plasma physics

    NASA Astrophysics Data System (ADS)

    1992-07-01

    The Applied Plasma Physics (APP) program at General Atomics (GA) described here includes four major elements: (1) Applied Plasma Physics Theory Program, (2) Alpha Particle Diagnostic, (3) Edge and Current Density Diagnostic, and (4) Fusion User Service Center (USC). The objective of the APP theoretical plasma physics research at GA is to support the DIII-D and other tokamak experiments and to significantly advance our ability to design a commercially-attractive fusion reactor. We categorize our efforts in three areas: magnetohydrodynamic (MHD) equilibria and stability; plasma transport with emphasis on H-mode, divertor, and boundary physics; and radio frequency (RF). The objective of the APP alpha particle diagnostic is to develop diagnostics of fast confined alpha particles using the interactions with the ablation cloud surrounding injected pellets and to develop diagnostic systems for reacting and ignited plasmas. The objective of the APP edge and current density diagnostic is to first develop a lithium beam diagnostic system for edge fluctuation studies on the Texas Experimental Tokamak (TEXT). The objective of the Fusion USC is to continue to provide maintenance and programming support to computer users in the GA fusion community. The detailed progress of each separate program covered in this report period is described.

  10. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    PubMed

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  11. Enhanced NIF neutron activation diagnostics.

    PubMed

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  12. Halo current diagnostic system of experimental advanced superconducting tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, D. L.; Shen, B.; Sun, Y.

    2015-10-15

    The design, calibration, and installation of disruption halo current sensors for the Experimental Advanced Superconducting Tokamak are described in this article. All the sensors are Rogowski coils that surround conducting structures, and all the signals are analog integrated. Coils with two different cross-section sizes have been fabricated, and their mutual inductances are calibrated. Sensors have been installed to measure halo currents in several different parts of both the upper divertor (tungsten) and lower divertor (graphite) at several toroidal locations. Initial measurements from disruptions show that the halo current diagnostics are working well.

  13. Design and testing of a magnetically driven implosion peak current diagnostic

    NASA Astrophysics Data System (ADS)

    Hess, M. H.; Peterson, K. J.; Ampleford, D. J.; Hutsel, B. T.; Jennings, C. A.; Gomez, M. R.; Dolan, D. H.; Robertson, G. K.; Payne, S. L.; Stygar, W. A.; Martin, M. R.; Sinars, D. B.

    2018-04-01

    A critical component of the magnetically driven implosion experiments at Sandia National Laboratories is the delivery of high-current, 10s of MA, from the Z pulsed power facility to a target. In order to assess the performance of the experiment, it is necessary to measure the current delivered to the target. Recent Magnetized Liner Inertial Fusion (MagLIF) experiments have included velocimetry diagnostics, such as PDV (Photonic Doppler Velocimetry) or Velocity Interferometer System for Any Reflector, in the final power feed section in order to infer the load current as a function of time. However, due to the nonlinear volumetrically distributed magnetic force within a velocimetry flyer, a complete time-dependent load current unfold is typically a time-intensive process and the uncertainties in the unfold can be difficult to assess. In this paper, we discuss how a PDV diagnostic can be simplified to obtain a peak current by sufficiently increasing the thickness of the flyer. This effectively keeps the magnetic force localized to the flyer surface, resulting in fast and highly accurate measurements of the peak load current. In addition, we show the results of experimental peak load current measurements from the PDV diagnostic in recent MagLIF experiments.

  14. Diagnostic Tools for the Systemic Reform of Schools.

    ERIC Educational Resources Information Center

    Amsler, Mary; Kirsch, Kayla

    This paper presents three interrelated diagnostic tools that can be used by school staff as they begin to plan a systemic reform effort. These tools are designed to help educators reflect on their experiences in creating changes in their school and to examine the current barriers to and supports for the change process. The tools help school design…

  15. Development of a Diagnostic System for Information Ethics Education

    ERIC Educational Resources Information Center

    Shiota, Shingo; Sakai, Kyohei; Kobayashi, Keita

    2016-01-01

    This paper presents a new diagnostic system for information ethics education. In order to educate children about information ethics, it is necessary to know the stage at which they currently are in terms of their knowledge of the same. Some actual condition surveys have been conducted by the Cabinet Office and the National Police Agency to gauge…

  16. Eponymous Psychiatric Syndromes Revisited.

    PubMed

    Naguy, Ahmed

    2018-02-22

    This report provides an anthology of psychiatric eponyms. Clinically, many of these described syndromes represent valid diagnostic constructs and may accommodate the atypical cases that defy the official diagnostic designation in the current classificatory systems in psychiatry. © Copyright 2018 Physicians Postgraduate Press, Inc.

  17. Revising the personality disorder diagnostic criteria for the Diagnostic and Statistical Manual of Mental Disorders-Fifth Edition (DSM-V): consider the later life context.

    PubMed

    Balsis, Steve; Segal, Daniel L; Donahue, Cailin

    2009-10-01

    The categorical measurement approach implemented by the Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition (DSM-IV) personality disorder (PD) diagnostic system is theoretically and pragmatically limited. As a result, many prominent psychologists now advocate for a shift away from this approach in favor of more conceptually sound dimensional measurement. This shift is expected to improve the psychometric properties of the personality disorder (PD) diagnostic system and make it more useful for clinicians and researchers. The current article suggests that despite the probable benefits of such a change, several limitations will remain if the new diagnostic system does not closely consider the context of later life. A failure to address the unique challenges associated with the assessment of personality in older adults likely will result in the continued limited validity, reliability, and utility of the Diagnostic and Statistical Manual of Mental Disorders (DSM) system for this growing population. This article discusses these limitations and their possible implications. (c) 2009 APA, all rights reserved.

  18. Influence of environmental tobacco smoke on morphology and functions of cardiovascular system assessed using diagnostic imaging.

    PubMed

    Gać, Paweł; Poręba, Małgorzata; Pawlas, Krystyna; Sobieszczańska, Małgorzata; Poręba, Rafał

    Exposure to tobacco smoke is a significant problem of environmental medicine. Tobacco smoke contains over one thousand identified chemicals including numerous toxicants. Cardiovascular system diseases are the major cause of general mortality. The recent development of diagnostic imaging provided methods which enable faster and more precise diagnosis of numerous diseases, also those of cardiovascular system. This paper reviews the most significant scientific research concerning relationship between environmental exposure to tobacco smoke and the morphology and function of cardiovascular system carried out using diagnostic imaging methods, i.e. ultrasonography, angiography, computed tomography and magnetic resonance imaging. In the forthcoming future, the studies using current diagnostic imaging methods should contribute to the reliable documentation, followed by the wide-spreading knowledge of the harmful impact of the environmental tobacco smoke exposure on the cardiovascular system.

  19. System theory in medical diagnostic devices: an overview.

    PubMed

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  20. Diagnostics in Japan's microgravity experiments

    NASA Technical Reports Server (NTRS)

    Kadota, Toshikazu

    1995-01-01

    The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.

  1. A first characterization of the NIO1 particle beam by means of a diagnostic calorimeter

    NASA Astrophysics Data System (ADS)

    Pimazzoni, A.; Cavenago, M.; Cervaro, V.; Fasolo, D.; Serianni, G.; Tollin, M.; Veltri, P.

    2017-08-01

    Powerful neutral beam injectors (NBI) are required as heating and current drive systems for tokamaks like ITER. The development of negative ion sources and accelerators (40 A; 1 MeV D- beam) in particular, is a crucial point and many issues still require a better understanding. In this framework, the experiment NIO1 (9 beamlets of 15 mA H- each, 60 kV) operated at Consorzio RFX started operation in 2014[1]. Both its RF negative ion source (up to 2.5 kW) and its beamline are equipped with many diagnostics [2]. For the early tests on the extraction system, oxygen has been used as well as hydrogen due to its higher electronegativity, which allows reaching currents large enough to test the beam diagnostics even without caesium injection. In particular a 1D-CFC (carbon-fibre-carbon composite) tile is used as a calorimeter to determine the beam power deposition by observing the rear surface of the tile with an infra-red camera; the same design is applied as for STRIKE [3], one of the diagnostics of SPIDER (the ITER-like ion source prototype [4]) whose facility is currently under construction at Consorzio RFX. From this diagnostic it is also possible to assess the beam divergence and thus the beam optics. The present contribution describes the characterization of the NIO1 particle beam by means of temperature and current measurements with different source and accelerator parameters.

  2. A Model-Based Expert System for Space Power Distribution Diagnostics

    NASA Technical Reports Server (NTRS)

    Quinn, Todd M.; Schlegelmilch, Richard F.

    1994-01-01

    When engineers diagnose system failures, they often use models to confirm system operation. This concept has produced a class of advanced expert systems that perform model-based diagnosis. A model-based diagnostic expert system for the Space Station Freedom electrical power distribution test bed is currently being developed at the NASA Lewis Research Center. The objective of this expert system is to autonomously detect and isolate electrical fault conditions. Marple, a software package developed at TRW, provides a model-based environment utilizing constraint suspension. Originally, constraint suspension techniques were developed for digital systems. However, Marple provides the mechanisms for applying this approach to analog systems such as the test bed, as well. The expert system was developed using Marple and Lucid Common Lisp running on a Sun Sparc-2 workstation. The Marple modeling environment has proved to be a useful tool for investigating the various aspects of model-based diagnostics. This report describes work completed to date and lessons learned while employing model-based diagnostics using constraint suspension within an analog system.

  3. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders.

    PubMed

    Mashamba-Thompson, Tivani P; Jama, Ngcwalisa A; Sartorius, Benn; Drain, Paul K; Thompson, Rowan M

    2017-01-08

    Key stakeholders' involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients' needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.

  4. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders

    PubMed Central

    Mashamba-Thompson, Tivani P.; Jama, Ngcwalisa A.; Sartorius, Benn; Drain, Paul K.; Thompson, Rowan M.

    2017-01-01

    Introduction: Key stakeholders’ involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. Method: We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. Results: 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients’ needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Conclusions: Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics. PMID:28075337

  5. Diagnostics for real-time plasma control in PBX-M

    NASA Astrophysics Data System (ADS)

    Kaita, R.; Batha, S.; Bell, R. E.; Bernabei, S.; Hatcher, R.; Kozub, T.; Kugel, H.; Levinton, F.; Okabayashi, M.; Sesnic, S.; von Goeler, S.; Zolfaghari, A.; PBX-M Group

    1995-01-01

    An important issue for future tokamaks is real-time plasma control for the avoidance of magnetohydrodynamic instabilities and other applications that require detailed plasma profile and fluctuation data. Although measurements from diagnostics providing this information require significantly more processing than magnetic flux data, recent advancements could make them practical for adjusting operational settings for plasma heating and current drive systems as well as field coil currents. On the Princeton Beta Experiment-Modification (PBX-M), the lower hybrid current drive phasing can be varied during a plasma shot using digitally programmable ferrite phase shifters, and neural beam functions can be fully computer controlled. PBX-M diagnostics that may be used for control purposes include motional Stark-effect polarimetry for magnetic field pitch angle profiles, soft x-ray arrays for plasma position control and the separation of βp from li, hard x-ray detectors for energetic electron distributions, a multichannel electron cyclotron emission radiometer for ballooning mode identification, and passive plate eddy current monitors for kink stabilization. We will describe the present status of these systems on PBX-M, and discuss their suitability for feedback applications.

  6. Are there financial savings associated with supplementing current diagnostic practice for preeclampsia with a novel test? Learnings from a modeling analysis from a German payer perspective.

    PubMed

    Hadker, Nandini; Garg, Suchita; Costanzo, Cory; van der Helm, Wim; Creeden, James

    2013-05-01

    To quantify the financial impact of adding a novel serum test to the current diagnostic toolkit for preeclampsia (PE) detection in Germany. A decision-analytic model was created to quantify the economic impact of adding a recently developed novel diagnostic test for PE (Roche Diagnostics, Rotkreuz, Switzerland) to current diagnostic practice in Germany. The model simulated a cohort of 1000 pregnant patients receiving obstetric care and quantified the budget impact of adding the novel test to current German PE detection and management practices. The model estimates that the costs associated with managing a typical pregnancy in Germany are €941 when the novel test is used versus €1579 with standard practice. This represents savings of €637 per pregnant woman, even when the test is used as a supplementary diagnostic tool. The savings are attributed to the novel test's ability to better classify patients relative to current practice, specifically, its ability to reduce false negatives by 67% and false positives by 71%. The novel PE test has the potential to provide substantial cost savings to German healthcare payers, even when used as an addition to standard practice. Better classification of patients at risk for developing PE and declassification of those that are not compared to current practice leads to economic savings for the healthcare system. Furthermore, by reducing the rates of false-positive and false-negative classification relative to current standard of care, the test helps better target healthcare spending and lowers overall costs associated with PE care.

  7. Gold Nanoparticles for Diagnostics: Advances towards Points of Care

    PubMed Central

    Cordeiro, Mílton; Ferreira Carlos, Fábio; Pedrosa, Pedro; Lopez, António; Baptista, Pedro Viana

    2016-01-01

    The remarkable physicochemical properties of gold nanoparticles (AuNPs) have prompted developments in the exploration of biomolecular interactions with AuNP-containing systems, in particular for biomedical applications in diagnostics. These systems show great promise in improving sensitivity, ease of operation and portability. Despite this endeavor, most platforms have yet to reach maturity and make their way into clinics or points of care (POC). Here, we present an overview of emerging and available molecular diagnostics using AuNPs for biomedical sensing that are currently being translated to the clinical setting. PMID:27879660

  8. Women-specific mental disorders in DSM-V: are we failing again?

    PubMed

    Wittchen, Hans-Ulrich

    2010-02-01

    Despite a wealth of studies on differences regarding the biobehavioral and social-psychological bases of mental disorders in men and women and repeated calls for increased attention, women-specific issues have so far not been comprehensively addressed in past diagnostic classification systems of mental disorders. There is also increasing evidence that this situation will not change significantly in the upcoming revisions of ICD-11 and DSM-V. This paper explores reasons for this continued failure, highlighting three major barriers: the fragmentation of the field of women's mental health research, lack of emphasis on diagnostic classificatory issues beyond a few selected clinical conditions, and finally, the "current rules of game" used by the current DSM-V Task Forces in the revision process of DSM-V. The paper calls for concerted efforts of researchers, clinicians, and other stakeholders within a more coherent and comprehensive framework aiming at broader coverage of women-specific diagnostic classificatory issues in future diagnostic systems.

  9. Calibrations of the LHD Thomson scattering system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, I., E-mail: yamadai@nifs.ac.jp; Funaba, H.; Yasuhara, R.

    2016-11-15

    The Thomson scattering diagnostic systems are widely used for the measurements of absolute local electron temperatures and densities of fusion plasmas. In order to obtain accurate and reliable temperature and density data, careful calibrations of the system are required. We have tried several calibration methods since the second LHD experiment campaign in 1998. We summarize the current status of the calibration methods for the electron temperature and density measurements by the LHD Thomson scattering diagnostic system. Future plans are briefly discussed.

  10. Calibrations of the LHD Thomson scattering system.

    PubMed

    Yamada, I; Funaba, H; Yasuhara, R; Hayashi, H; Kenmochi, N; Minami, T; Yoshikawa, M; Ohta, K; Lee, J H; Lee, S H

    2016-11-01

    The Thomson scattering diagnostic systems are widely used for the measurements of absolute local electron temperatures and densities of fusion plasmas. In order to obtain accurate and reliable temperature and density data, careful calibrations of the system are required. We have tried several calibration methods since the second LHD experiment campaign in 1998. We summarize the current status of the calibration methods for the electron temperature and density measurements by the LHD Thomson scattering diagnostic system. Future plans are briefly discussed.

  11. 75 FR 32519 - Miracor Diagnostics, Inc., Monaco Finance, Inc., MPEL Holdings Corp. (f/k/a Computer Transceiver...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] Miracor Diagnostics, Inc., Monaco Finance, Inc., MPEL Holdings Corp. (f/k/a Computer Transceiver Systems, Inc.), MR3 Systems, Inc., Mutual Risk Management, Ltd.; Order of Suspension of Trading June 4, 2010. It appears to the Securities and Exchange Commission that there is a lack of current and...

  12. Better Tests, Better Care: Improved Diagnostics for Infectious Diseases

    PubMed Central

    Caliendo, Angela M.; Gilbert, David N.; Ginocchio, Christine C.; Hanson, Kimberly E.; May, Larissa; Quinn, Thomas C.; Tenover, Fred C.; Alland, David; Blaschke, Anne J.; Bonomo, Robert A.; Carroll, Karen C.; Ferraro, Mary Jane; Hirschhorn, Lisa R.; Joseph, W. Patrick; Karchmer, Tobi; MacIntyre, Ann T.; Reller, L. Barth; Jackson, Audrey F.

    2013-01-01

    In this IDSA policy paper, we review the current diagnostic landscape, including unmet needs and emerging technologies, and assess the challenges to the development and clinical integration of improved tests. To fulfill the promise of emerging diagnostics, IDSA presents recommendations that address a host of identified barriers. Achieving these goals will require the engagement and coordination of a number of stakeholders, including Congress, funding and regulatory bodies, public health agencies, the diagnostics industry, healthcare systems, professional societies, and individual clinicians. PMID:24200831

  13. Center conductor diagnostic for multipactor detection in inaccessible geometries

    NASA Astrophysics Data System (ADS)

    Chaplin, Vernon H.; Hubble, Aimee A.; Clements, Kathryn A.; Graves, Timothy P.

    2017-01-01

    Electron collecting current probes are the most reliable diagnostic of multipactor and radiofrequency (RF) ionization breakdown; however, stand-alone probes can only be used in test setups where the breakdown region is physically accessible. This paper describes techniques for measuring multipactor current directly on the center conductor of a coaxial RF device (or more generally, on the signal line in any two-conductor RF system) enabling global multipactor detection with improved sensitivity compared to other common diagnostics such as phase null, third harmonic, and reflected power. The center conductor diagnostic may be AC coupled for use in systems with a low DC impedance between the center conductor and ground. The effect of DC bias on the breakdown threshold was studied: in coaxial geometry, the change in threshold was <1 dB for positive biases satisfying VD C/VR F 0 <0.8 , where VRF0 is the RF voltage amplitude at the unperturbed breakdown threshold. In parallel plate geometry, setting VD C/VR F 0 <0.2 was necessary to avoid altering the threshold by more than 1 dB. In most cases, the center conductor diagnostic functions effectively with no bias at all—this is the preferred implementation, but biases in the range VD C=0 -10 V may be applied if necessary. The polarity of the detected current signal may be positive or negative depending on whether there is net electron collection or emission globally.

  14. Center conductor diagnostic for multipactor detection in inaccessible geometries.

    PubMed

    Chaplin, Vernon H; Hubble, Aimee A; Clements, Kathryn A; Graves, Timothy P

    2017-01-01

    Electron collecting current probes are the most reliable diagnostic of multipactor and radiofrequency (RF) ionization breakdown; however, stand-alone probes can only be used in test setups where the breakdown region is physically accessible. This paper describes techniques for measuring multipactor current directly on the center conductor of a coaxial RF device (or more generally, on the signal line in any two-conductor RF system) enabling global multipactor detection with improved sensitivity compared to other common diagnostics such as phase null, third harmonic, and reflected power. The center conductor diagnostic may be AC coupled for use in systems with a low DC impedance between the center conductor and ground. The effect of DC bias on the breakdown threshold was studied: in coaxial geometry, the change in threshold was <1 dB for positive biases satisfying V DC /V RF0 <0.8, where V RF0 is the RF voltage amplitude at the unperturbed breakdown threshold. In parallel plate geometry, setting V DC /V RF0 <0.2 was necessary to avoid altering the threshold by more than 1 dB. In most cases, the center conductor diagnostic functions effectively with no bias at all-this is the preferred implementation, but biases in the range V DC =0-10V may be applied if necessary. The polarity of the detected current signal may be positive or negative depending on whether there is net electron collection or emission globally.

  15. An ontology-driven, diagnostic modeling system.

    PubMed

    Haug, Peter J; Ferraro, Jeffrey P; Holmen, John; Wu, Xinzi; Mynam, Kumar; Ebert, Matthew; Dean, Nathan; Jones, Jason

    2013-06-01

    To present a system that uses knowledge stored in a medical ontology to automate the development of diagnostic decision support systems. To illustrate its function through an example focused on the development of a tool for diagnosing pneumonia. We developed a system that automates the creation of diagnostic decision-support applications. It relies on a medical ontology to direct the acquisition of clinic data from a clinical data warehouse and uses an automated analytic system to apply a sequence of machine learning algorithms that create applications for diagnostic screening. We refer to this system as the ontology-driven diagnostic modeling system (ODMS). We tested this system using samples of patient data collected in Salt Lake City emergency rooms and stored in Intermountain Healthcare's enterprise data warehouse. The system was used in the preliminary development steps of a tool to identify patients with pneumonia in the emergency department. This tool was compared with a manually created diagnostic tool derived from a curated dataset. The manually created tool is currently in clinical use. The automatically created tool had an area under the receiver operating characteristic curve of 0.920 (95% CI 0.916 to 0.924), compared with 0.944 (95% CI 0.942 to 0.947) for the manually created tool. Initial testing of the ODMS demonstrates promising accuracy for the highly automated results and illustrates the route to model improvement. The use of medical knowledge, embedded in ontologies, to direct the initial development of diagnostic computing systems appears feasible.

  16. Recent advances in tuberculosis diagnostics in resource-limited settings.

    PubMed

    Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi

    2018-04-19

    Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.

  17. Noise level measurements on the UMTA Mark I Diagnostic Car (R42 MODEL)

    DOT National Transportation Integrated Search

    1971-10-01

    The R42 Model mass transit car currently operating on the "N" line of the new York City Transit System was selected for experimentation and tests. For this purpose, the car was instrumented and designated as the UMTA Mark I Diagnostic Car. Noise leve...

  18. Beyond the DSM-IV: Assumptions, Alternatives, and Alterations

    ERIC Educational Resources Information Center

    Lopez, Shane J.; Edwards, Lisa M.; Pedrotti, Jennifer Teramoto; Prosser, Ellie C.; LaRue, Stephanie; Spalitto, Susan Vehige; Ulven, Jon C.

    2006-01-01

    Current diagnostic processes reflect the limitations and utility of the framework of the "Diagnostic and Statistical Manual of Mental Disorders" (4th ed.; DSM-IV; American Psychiatric Association, 1994). Clinical information in the DSM-IV's 5-axis system almost exclusively focuses on weaknesses and pathology and is summarized in a flawed…

  19. Comprehensive description of the Orion laser facility

    NASA Astrophysics Data System (ADS)

    Hopps, Nicholas; Oades, Kevin; Andrew, Jim; Brown, Colin; Cooper, Graham; Danson, Colin; Daykin, Simon; Duffield, Stuart; Edwards, Ray; Egan, David; Elsmere, Stephen; Gales, Steve; Girling, Mark; Gumbrell, Edward; Harvey, Ewan; Hillier, David; Hoarty, David; Horsfield, Colin; James, Steven; Leatherland, Alex; Masoero, Stephen; Meadowcroft, Anthony; Norman, Michael; Parker, Stefan; Rothman, Stephen; Rubery, Michael; Treadwell, Paul; Winter, David; Bett, Thomas

    2015-06-01

    The Orion laser facility at the atomic weapons establishment (AWE) in the UK has been operational since April 2013, fielding experiments that require both its long and short pulse capability. This paper provides a full description of the facility in terms of laser performance, target systems and diagnostics currently available. Inevitably, this is a snapshot of current capability—the available diagnostics and the laser capability are evolving continuously. The laser systems consist of ten beams, optimised around 1 ns pulse duration, which each provide a nominal 500 J at a wavelength of 351 nm. There are also two short pulse beams, which each provide 500 J in 0.5 ps at 1054 nm. There are options for frequency doubling one short pulse beam to enhance the pulse temporal contrast. More recently, further contrast enhancement, based on optical parametric amplification (OPA) in the front end with a pump pulse duration of a few ps, has been installed. An extensive suite of diagnostics are available for users, probing the optical emission, x-rays and particles produced in laser-target interactions. Optical probe diagnostics are also available. A description of the diagnostics is provided.

  20. Can and should value-based pricing be applied to molecular diagnostics?

    PubMed

    Garau, Martina; Towse, Adrian; Garrison, Louis; Housman, Laura; Ossa, Diego

    2013-01-01

    Current pricing and reimbursement systems for diagnostics are not efficient. Prices for diagnostics are often driven by administrative practices and expected production cost. The purpose of the paper is to discuss how a value-based pricing framework being used to ensure efficient use and price of medicines could also be applied to diagnostics. Diagnostics not only facilitates health gain and cost savings, but also information to guide patients' decisions on interventions and their future 'behaviors'. For value assessment processes we recommend a two-part approach. Companion diagnostics introduced at the launch of the drug should be assessed through new drug assessment processes considering a broad range of value elements and a balanced analysis of diagnostic impacts. A separate diagnostic-dedicated committee using value-based pricing principles should review other diagnostics lying outside the companion diagnostics-and-drug 'at-launch' situation.

  1. The role of modern diagnostic imaging in diagnosing and differentiating kidney diseases in children.

    PubMed

    Maliborski, Artur; Zegadło, Arkadiusz; Placzyńska, Małgorzata; Sopińska, Małgorzata; Lichosik, Marianna; Jobs, Katarzyna

    2018-01-01

    Urinary tract diseases are in the group of the most commonly diagnosed medical conditions in pediatric patients. Many diseases with different etiologies are accompanied by pain, fever, hematuria, or urinary tract dysfunction. Those most common ones in children are urinary tract infections and congenital malformation. They can also represent tumors or changes caused by systemic diseases. Clinical tests and even more often additional imaging studies are required to make a proper diagnosis of urinary tract diseases. Just a few decades ago urography, cystography or voiding cystourethrography were the main methods in diagnostic imaging of the urinary tract. Today's imaging methods supported by digital radiographic and fluoroscopy systems, high sensitivity detectors with quantum detection, advanced algorithms eliminating motion artifacts, modern medical imaging monitors with a resolution of three or even eight megapixels significantly differ from conventional radiographic methods. The methods that are currently usually performed are: computed tomography, magnetic resonance imaging, isotopic methods and ultrasonography using elastography and new solutions in Doppler imaging. Modern techniques are currently focused on reducing radiation exposure with better imaging capabilities. The development of these techniques became an essential diagnostic aid in nephrological and urological practice. The aim of this paper is to present the latest solutions that are currently used in the diagnostic imaging of urinary tract diseases.

  2. Update on diagnostics for Phytophthora ramorum

    Treesearch

    Philip Berger

    2006-01-01

    Diagnostics used by the U.S. Department of Agriculture (USDA), to determine absence or presence of Phytophthora ramorum in plant samples, are based on a combination of tests and depend on collaboration with external laboratories. The system currently in place attempts to maximize limited resources and at the same time provide the most scientifically...

  3. First results with a lab-on-a-chip system for a fast Phytophthora diagnosis.

    Treesearch

    Sonja Horatzek; Stephan König; Stefan Wagner; Sabine Werres; Lydia Schwenkbier; Karina Weber; Jörg. Weber

    2013-01-01

    For Phytophthora spp. that are quarantine or regulated organisms, highly specific and sensitive diagnostic tools are recommended for surveys and monitoring. Furthermore, these diagnostic techniques should give results within a short time and should be not be too expensive. The techniques currently used for routine diagnosis of ...

  4. Nanomedicines in gastroenterology and hepatology.

    PubMed

    Lamprecht, Alf

    2015-04-01

    Nanoscale systems are currently under investigation for multiple different diagnostic and therapeutic applications. These systems can be used to identify pathologically changed tissues or to selectively deliver drugs to these sites; both applications have an extremely high potential to ameliorate therapeutic outcomes for patients. Tissues as well as single cells can be targeted because of the small size of these systems, which enables enhanced diagnosis and increased specificity of therapy. Drug loads can be delivered directly to the site of action, which can result in a reduction in incidence and severity of adverse systemic effects. Several nano-based platform technologies are currently under investigation for use in therapeutic approaches, mainly for anti-inflammatory and anti-cancer therapies. Although many nanoscale systems show promising therapeutic outcomes in preclinical studies, only a limited number are ready for clinical use. This Review will discuss the diverse nanomaterials currently available and the first specific uses for select gastroenterological and hepatological pathologies. The discussion of diagnostic and therapeutic applications will consider realities of market introduction of these sometimes very complex systems in light of remaining regulatory challenges and hurdles for industrial production.

  5. Current and emerging technologies in melanoma diagnosis: the state of the art

    PubMed Central

    Psaty, Estee L.; Halpern, Allan C.

    2017-01-01

    Relative to other specialties, dermatologists have been slow to adopt advanced technologic diagnostic aids. After all, most skin disease can be diagnosed by simple visual inspection, and the skin is readily accessible for a diagnostic biopsy. Diagnostic aids such as total body photography and dermoscopy improve the clinician's ability to diagnose melanoma beyond unaided visual inspection, however, and are now considered mainstream methods for early detection. Emerging technologies such as in vivo reflectance confocal microscopy are currently being investigated to determine their utility for noninvasive diagnosis of melanoma. This review summarizes the currently available cutaneous imaging devices and new frontiers in noninvasive diagnosis of skin disease. We anticipate that multimodal systems that combine different imaging technologies will further improve our ability to detect, at the bedside, melanoma at an earlier stage. PMID:19095152

  6. Critical appraisal of the 1977 diagnostic criteria for Minamata disease.

    PubMed

    Yorifuji, Takashi; Tsuda, Toshihide; Inoue, Sachiko; Takao, Soshi; Harada, Masazumi; Kawachi, Ichiro

    2013-01-01

    Large-scale food poisoning caused by methylmercury was identified in Minamata, Japan, in the 1950s (Minamata disease). Although the diagnostic criteria for the disease remain current, few studies have been carried out to assess the diagnostic accuracy of the criteria. From a 1971 population-based investigation, data from 2 villages were selected: Minamata (high-exposure area; n = 779) and Ariake (low-exposure area; n = 755). The authors examined the prevalence of neurologic signs characteristic of methylmercury poisoning and the validity of the criteria. A substantial number of residents in the exposed area exhibited neurologic signs even after excluding officially certified patients. Using paresthesia of the extremities as the gold standard of diagnosis, the criteria had a sensitivity of 66%. The current diagnostic criteria as well as the official certification system substantially underestimate the incidence of Minamata disease.

  7. Diagnosis of schizophrenia: a critical review of current diagnostic systems.

    PubMed

    Fenton, W S; Mosher, L R; Matthews, S M

    1981-01-01

    The data relevant to the evaluation of six systems for diagnosing schizophrenia are reviewed. They are summarized in terms of the reliability, predictive validity, specificity, and comprehensiveness of each system. Unfortunately, none, of these systems (Schneider's First-rank Symptoms, New Haven Schizophrenia Index, Flexible System, Feighner Criteria, Research Diagnostic Criteria, and DSM-III) have established construct validity. It is noted therefore that they are all, in a sense, arbitrary. Choosing one over another cannot be data-based. Because the elevation of any one diagnostic system to an official status is thought to be premature, clinicians and researchers alike are advised to exercise caution and openmindedness in their use of DSM-III. There is as yet no evidence that its criteria for schizophrenia are either less arbitrary or better (in identifying a group of "true" schizophrenics) than those of other systems or DSM-II.

  8. Diagnostic Systems Plan for the Advanced Light Source Top-OffUpgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barry, Walter; Chin, Mike; Robin, David

    2005-05-10

    The Advanced Light Source (ALS) will soon be upgraded to enable top-off operations [1], in which electrons are quasi-continuously injected to produce constant stored beam current. The upgrade is structured in two phases. First, we will upgrade our injector from 1.5 GeV to 1.9 GeV to allow full energy injection and will start top-off operations. In the second phase, we will upgrade the Booster Ring (BR) with a bunch cleaning system to allow high bunch purity top-off injection. A diagnostics upgrade will be crucial for success in both phases of the top-off project, and our plan for it is describedmore » in this paper. New booster ring diagnostics will include updated beam position monitor (BPM) electronics, a tune monitoring system, and a new scraper. Two new synchrotron light monitors and a beam stop will be added to the booster-to-storage ring transfer line (BTS), and all the existing beam current monitors along the accelerator chain will be integrated into a single injection efficiency monitoring application. A dedicated bunch purity monitor will be installed in the storage ring (SR). Together, these diagnostic upgrades will enable smooth commissioning of the full energy injector and a quick transition to high quality top-off operation at the ALS.« less

  9. Cavity ring down spectrometry for disease diagnostics using exhaled air

    NASA Astrophysics Data System (ADS)

    Revalde, G.; Grundšteins, K.; Alnis, J.; Skudra, A.

    2017-12-01

    In this paper we report the current stage of the development of a cavity ring-down spectrometer (CRDS) system using exhaled human breath analysis for the diagnostics of different diseases like diabetes and later lung cancer. The portable CRDS system is made in ultraviolet spectral region using Nd:Yag laser 266 nm pulsed light. Calibration of the CRDS system was performed using generated samples by KinTek automated permeation tube system and self-prepared mixtures with known concentration of benzene and acetone in air. First experiments showed that the limits of detection for benzene and acetone are several tens of ppb.

  10. Applications of DC-Self Bias in CCP Deposition Systems

    NASA Astrophysics Data System (ADS)

    Keil, D. L.; Augustyniak, E.; Sakiyama, Y.

    2013-09-01

    In many commercial CCP plasma process systems the DC-self bias is available as a reported process parameter. Since commercial systems typically limit the number of onboard diagnostics, there is great incentive to understand how DC-self bias can be expected to respond to various system perturbations. This work reviews and examines DC self bias changes in response to tool aging, chamber film accumulation and wafer processing. The diagnostic value of the DC self bias response to transient and various steady state current draw schemes are examined. Theoretical models and measured experimental results are compared and contrasted.

  11. Saliva diagnostics – Current views and directions

    PubMed Central

    Kaczor-Urbanowicz, Karolina Elżbieta; Martin Carreras-Presas, Carmen; Aro, Katri; Tu, Michael; Wong, David TW

    2016-01-01

    In this review, we provide an update on the current and future applications of saliva for diagnostic purposes. There are many advantages of using saliva as a biofluid. Its collection is fast, easy, inexpensive, and non-invasive. In addition, saliva, as a “mirror of the body,” can reflect the physiological and pathological state of the body. Therefore, it serves as a diagnostic and monitoring tool in many fields of science such as medicine, dentistry, and pharmacotherapy. Introduced in 2008, the term “Salivaomics” aimed to highlight the rapid development of knowledge about various “omics” constituents of saliva, including: proteome, transcriptome, micro-RNA, metabolome, and microbiome. In the last few years, researchers have developed new technologies and validated a wide range of salivary biomarkers that will soon make the use of saliva a clinical reality. However, a great need still exists for convenient and accurate point-of-care devices that can serve as a non-invasive diagnostic tool. In addition, there is an urgent need to decipher the scientific rationale and mechanisms that convey systemic diseases to saliva. Another promising technology called liquid biopsy enables detection of circulating tumor cells (CTCs) and fragments of tumor DNA in saliva, thus enabling non-invasive early detection of various cancers. The newly developed technology—electric field-induced release and measurement (EFIRM) provides near perfect detection of actionable mutations in lung cancer patients. These recent advances widened the salivary diagnostic approach from the oral cavity to the whole physiological system, and thus point towards a promising future of salivary diagnostics for personalized individual medicine applications including clinical decisions and post-treatment outcome predictions. Impact statement The purpose of this mini-review is to make an update about the present and future applications of saliva as a diagnostic biofluid in many fields of science such as dentistry, medicine and pharmacotherapy. Using saliva as a fluid for diagnostic purposes would be a huge breakthrough for both patients and healthcare providers since saliva collection is easy, non-invasive and inexpensive. We will go through the current main diagnostic applications of saliva, and provide a highlight on the emerging, newly developing technologies and tools for cancer screening, detection and monitoring. PMID:27903834

  12. Architecture for a PACS primary diagnosis workstation

    NASA Astrophysics Data System (ADS)

    Shastri, Kaushal; Moran, Byron

    1990-08-01

    A major factor in determining the overall utility of a medical Picture Archiving and Communications (PACS) system is the functionality of the diagnostic workstation. Meyer-Ebrecht and Wendler [1] have proposed a modular picture computer architecture with high throughput and Perry et.al [2] have defined performance requirements for radiology workstations. In order to be clinically useful, a primary diagnosis workstation must not only provide functions of current viewing systems (e.g. mechanical alternators [3,4]) such as acceptable image quality, simultaneous viewing of multiple images, and rapid switching of image banks; but must also provide a diagnostic advantage over the current systems. This includes window-level functions on any image, simultaneous display of multi-modality images, rapid image manipulation, image processing, dynamic image display (cine), electronic image archival, hardcopy generation, image acquisition, network support, and an easy user interface. Implementation of such a workstation requires an underlying hardware architecture which provides high speed image transfer channels, local storage facilities, and image processing functions. This paper describes the hardware architecture of the Siemens Diagnostic Reporting Console (DRC) which meets these requirements.

  13. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    PubMed

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  14. RANZCR Body Systems Framework of diagnostic imaging examination descriptors.

    PubMed

    Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia

    2014-08-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.

  15. A 'difficult' insect allergy patient: reliable history of a sting, but all testing negative.

    PubMed

    Tracy, James M; Olsen, Jonathan A; Carlson, John

    2015-08-01

    Few conditions are as treatable as allergy to stinging insects, with venom immunotherapy (VIT) providing up to 98% protection to subsequent stings. The challenge with VIT is not in the treatment, but in the diagnosis. To offer VIT, one must determine a history of a systemic reaction to a stinging insect in conjunction with the presence venom-specific IgE. Current diagnostic methods, although sensitive and specific, are imperfect, and some newer testing options are not widely available. A conundrum occasionally faced is the patient with a reliable and compelling history of a systemic allergic reaction yet negative venom-specific testing. This diagnostic dilemma presents an opportunity to consider possible causes for this diagnostic challenge. Our evolving understanding of the role of occult mast cell disease may begin to help us understand this situation and develop appropriate management strategies. Venom-specific skin testing has long been the cornerstone of the evaluation of venom sensitivity and is often combined with in-vitro assays to add clarity, but even these occasionally may fall short. Exploring novel venom diagnostic testing methods may help to fill in some of the diagnostic gaps. Do currently available venom vaccines contain all the key venom species? Are there enough differences between insect species that we may simply be missing the relevant allergens? What is the significance of the antigenicity of carbohydrate moieties in venoms? What is the role of recombinant venom extracts? VIT is the definitive treatment for insect allergic individuals. To utilize VIT, identification of the relevant Hymenoptera is necessary. Unfortunately, this cannot always be accomplished. This deficiency can have several causes: a potential comorbid condition such as occult mast cell disease, limitations of currently available diagnostic resources, or testing vaccines with an insufficient coverage of relevant venom allergens. Exploring these potential causes may help to provide important insight into this important diagnostic conundrum. The use of a case report may help clarify this challenge.

  16. Signal processing in ultrasound. [for diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Le Croissette, D. H.; Gammell, P. M.

    1978-01-01

    Signal is the term used to denote the characteristic in the time or frequency domain of the probing energy of the system. Processing of this signal in diagnostic ultrasound occurs as the signal travels through the ultrasonic and electrical sections of the apparatus. The paper discusses current signal processing methods, postreception processing, display devices, real-time imaging, and quantitative measurements in noninvasive cardiology. The possibility of using deconvolution in a single transducer system is examined, and some future developments using digital techniques are outlined.

  17. Sensor Data Qualification for Autonomous Operation of Space Systems

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Melcher, Kevin J.; Chicatelli, Amy K.; Sowers, T. Shane

    2006-01-01

    NASA's new Exploration initiative for both robotic and manned missions will require higher levels of reliability, autonomy and reconfiguration capability to make the missions safe, successful and affordable. Future systems will require diagnostic reasoning to assess the health of the system in order to maintain the system s functionality. The diagnostic reasoning and assessment will involve data qualification, fault detection, fault isolation and remediation control. A team of researchers at the NASA Glenn Research Center is currently working on a Sensor Data Qualification (SDQ) system that will support these critical evaluation processes, for both automated and human-in-the-loop applications. Data qualification is required as a first step so that critical safety and operational decisions are based on good data. The SDQ system would monitor a network of related sensors to determine the health of individual sensors within that network. Various diagnostic systems such as the Caution and Warning System would then use the sensor health information with confidence. The proposed SDQ technology will be demonstrated on a variety of subsystems that are relevant to NASA s Exploration systems, which currently include an electrical power system and a cryogenic fluid management system. The focus of this paper is the development and demonstration of a SDQ application for a prototype power distribution unit that is representative of a Crew Exploration Vehicle electrical power system; this provides a unique and relevant environment in which to demonstrate the feasibility of the SDQ technology.

  18. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  19. Diagnostic imaging of the nasolacrimal drainage system. Part I. Radiological anatomy of lacrimal pathways. Physiology of tear secretion and tear outflow.

    PubMed

    Maliborski, Artur; Różycki, Radosław

    2014-04-17

    Excessive watering of the eye is a common condition in ophthalmological practice. It may be the result of excessive production of tear fluid or obstruction and insufficiency of efferent tear pathways. The differentiation between obstruction and insufficiency of the lacrimal pathways is still clinically questionable. In the diagnostic process it is necessary to perform clinical tests and additional diagnostic imaging is often needed. Dacryocystography, with or without the extension of the dynamic phase or subtraction option, still remains the criterion standard for diagnostic imaging of the lacrimal obstruction. It may help to clarify the cause and exact place of the obstruction and provide information for further management, especially surgical treatment. Increasingly, new techniques are used in diagnostic imaging of the lacrimal tract, such as computed tomography, magnetic resonance, and isotopic methods. Adequate knowledge of the anatomy and physiology of the lacrimal system and the secretion and outflow of tears is the basis for proper diagnostic imaging. The purpose of this paper is to present the exact anatomy of the lacrimal system, with particular emphasis on the radiological anatomy and the current state of knowledge about the physiology of tear secretion and drainage.

  20. Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nazififard, Mohammad, E-mail: nazifi@kashanu.ac.ir; Mahmoudieh, Afshin; Suh, Kune Y.

    Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty.more » Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.« less

  1. Sensors for noncontact vibration diagnostics in rotating machinery

    NASA Astrophysics Data System (ADS)

    Procházka, Pavel

    2016-06-01

    The paper deals with electromagnetic sensors for noncontact vibration diagnostics in rotating machinery. The sensors were designed for operational measurements in turbomachinery by means of the tip-timing method. The main properties of eddy-current, Hall effect, induction and magnetoresistive sensors are described and compared. Possible arrangements of the experimental systems for static and dynamic calibration of the sensors are suggested and discussed.

  2. Development of an Adaptable Display and Diagnostic System for the Evaluation of Tropical Cyclone Forecasts

    NASA Astrophysics Data System (ADS)

    Kucera, P. A.; Burek, T.; Halley-Gotway, J.

    2015-12-01

    NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.

  3. [The current clinical laboratory in the public health system and medical science: a lecture].

    PubMed

    Men'shikov, V V

    2011-11-01

    The analytic and diagnostic possibilities of current clinical laboratories are discussed. The roles of laboratory information in the formation of new research directions are characterized. The proposals on the development of economic basics of the development of laboratory medicine.

  4. Information engineering for molecular diagnostics.

    PubMed Central

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  5. Beam diagnostics at high-intensity storage rings

    NASA Astrophysics Data System (ADS)

    Plum, Mike

    1994-10-01

    Beam diagnostics at high-intensity facilities feature their own special set of problems and characteristics, issues peculiar to high-intensity storage rings include beam loss, beam halos, extraction efficiency, beam in the gap, clearing electrodes, and beam-profile measurement. The Los Alamos Proton Storage Ring (PSR) is a nice example of a high-intensity storage ring. I will discuss in some detail three diagnostic systems currently in use at the PSR: the beam-loss-monitor system, the electron-clearing system, and the beam-in-the-gap monitor. Much of our discussion is inspired by the problems we have encountered and the useful things we have learned while commissioning and developing the PSR. Another inspiration is our work on the next-generation neutron-spallation source, also known as the National Center for Neutron Research (NCNR).

  6. On-line experimental validation of a model-based diagnostic algorithm dedicated to a solid oxide fuel cell system

    NASA Astrophysics Data System (ADS)

    Polverino, Pierpaolo; Esposito, Angelo; Pianese, Cesare; Ludwig, Bastian; Iwanschitz, Boris; Mai, Andreas

    2016-02-01

    In the current energetic scenario, Solid Oxide Fuel Cells (SOFCs) exhibit appealing features which make them suitable for environmental-friendly power production, especially for stationary applications. An example is represented by micro-combined heat and power (μ-CHP) generation units based on SOFC stacks, which are able to produce electric and thermal power with high efficiency and low pollutant and greenhouse gases emissions. However, the main limitations to their diffusion into the mass market consist in high maintenance and production costs and short lifetime. To improve these aspects, the current research activity focuses on the development of robust and generalizable diagnostic techniques, aimed at detecting and isolating faults within the entire system (i.e. SOFC stack and balance of plant). Coupled with appropriate recovery strategies, diagnosis can prevent undesired system shutdowns during faulty conditions, with consequent lifetime increase and maintenance costs reduction. This paper deals with the on-line experimental validation of a model-based diagnostic algorithm applied to a pre-commercial SOFC system. The proposed algorithm exploits a Fault Signature Matrix based on a Fault Tree Analysis and improved through fault simulations. The algorithm is characterized on the considered system and it is validated by means of experimental induction of faulty states in controlled conditions.

  7. 42 CFR 414.65 - Payment for telehealth services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... professional service via an interactive telecommunications system is made according to the following... psychotherapy, psychiatric diagnostic interview examination, pharmacologic management, end-stage renal disease... intervention services furnished via an interactive telecommunications system is equal to the current fee...

  8. Current Research Activities in Drive System Technology in Support of the NASA Rotorcraft Program

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Zakrajsek, James J.

    2006-01-01

    Drive system technology is a key area for improving rotorcraft performance, noise/vibration reduction, and reducing operational and manufacturing costs. An overview of current research areas that support the NASA Rotorcraft Program will be provided. Work in drive system technology is mainly focused within three research areas: advanced components, thermal behavior/emergency lubrication system operation, and diagnostics/prognostics (also known as Health and Usage Monitoring Systems (HUMS)). Current research activities in each of these activities will be presented. Also, an overview of the conceptual drive system requirements and possible arrangements for the Heavy Lift Rotorcraft program will be reviewed.

  9. Intelligent model-based diagnostics for vehicle health management

    NASA Astrophysics Data System (ADS)

    Luo, Jianhui; Tu, Fang; Azam, Mohammad S.; Pattipati, Krishna R.; Willett, Peter K.; Qiao, Liu; Kawamoto, Masayuki

    2003-08-01

    The recent advances in sensor technology, remote communication and computational capabilities, and standardized hardware/software interfaces are creating a dramatic shift in the way the health of vehicles is monitored and managed. These advances facilitate remote monitoring, diagnosis and condition-based maintenance of automotive systems. With the increased sophistication of electronic control systems in vehicles, there is a concomitant increased difficulty in the identification of the malfunction phenomena. Consequently, the current rule-based diagnostic systems are difficult to develop, validate and maintain. New intelligent model-based diagnostic methodologies that exploit the advances in sensor, telecommunications, computing and software technologies are needed. In this paper, we will investigate hybrid model-based techniques that seamlessly employ quantitative (analytical) models and graph-based dependency models for intelligent diagnosis. Automotive engineers have found quantitative simulation (e.g. MATLAB/SIMULINK) to be a vital tool in the development of advanced control systems. The hybrid method exploits this capability to improve the diagnostic system's accuracy and consistency, utilizes existing validated knowledge on rule-based methods, enables remote diagnosis, and responds to the challenges of increased system complexity. The solution is generic and has the potential for application in a wide range of systems.

  10. Investigation of Radio Frequency Discharges and Langmuir Probe Diagnostic Methods in a Fast Flowing Electronegative Background Gas

    DTIC Science & Technology

    2007-12-01

    Pinhero and others, 1998). The Air Force is currently developing the Electric Chemical Oxygen Iodine Laser (ElectriCOIL) system to replace the liquid...chemistry generator currently used in the Air Borne Laser (ABL) system (Zimmerman and others, 2003). The ElectriCOIL system produces in a radio...convected downstream is critical to improving the performance of the ABL system . The use of a second non-self sustained discharge operating at a lower

  11. Surgical management of patients with primary brain tumors.

    PubMed

    Bohan, Eileen; Glass-Macenka, Deanna

    2004-11-01

    To provide an overview of the diagnostic work-up, intraoperative technologies, postoperative treatment options, and investigational new therapies in patients with malignant brain tumors. Published textbooks and articles and other reference materials. Recent improvements in diagnostic and surgical equipment have influenced outcomes and overall quality of life for patients with central nervous system tumors. The ability to more accurately target and more safely remove brain tumors has enhanced the postoperative period and decreased hospital stays. However, malignant neoplasms continue to be refractory to current treatments, necessitating innovative surgical approaches at the time of initial diagnosis and at tumor recurrence. Nurses with an understanding of current diagnostic and surgical treatment modalities for brain tumors are able to provide accurate patient education and comprehensive care, enhancing the overall hospital and outpatient experience.

  12. [Critical evaluation of current diagnostic classification systems in psychiatry: the case of DSM-5].

    PubMed

    Luciano, Mario; Sampogna, Gaia; Del Vecchio, Valeria; De Rosa, Corrado; Albert, Umberto; Carrà, Giuseppe; Dell'Osso, Bernardo; Lorenzo, Giorgio Di; Ferrari, Silvia; Martinotti, Giovanni; Nanni, Maria Giulia; Pinna, Federica; Pompili, Maurizio; Volpe, Umberto; Catapano, Francesco; Fiorillo, Andrea

    2016-01-01

    Since its first edition, the Diagnostic and Statistical manual of Mental disorders (DSM) has had a great impact on the scientific community and the public opinion as well. In 2013, the American Psychiatric Association released the fifth edition of the manual and - as for the previous versions - several criticisms raised. In particular, the persistence of the categorical approach to mental disorders represents one of the main debated topics, as well as the introduction of new diagnostic syndromes, which are not based on an adequate evidences. Moreover, the threshold of diagnostic criteria for many mental disorders has been lowered, with the consequence that the boundaries between "normality" and "pathology" is not so clear. In this paper, we will: 1) report the historical development of the DSM from the publication of its first edition; 2) describe the main changes introduced in the DSM-5; 3) discuss critical elements in the DSM-5. The current debate regarding the validity of diagnostic manuals and its criteria is threatening the psychiatric discipline, but a possible solution should be represented by the integration of diagnostic criteria with the in-depth description of patient's psychopathological experiences.

  13. Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baiao, D.; Varandas, C.; Medina, F.

    2012-10-15

    Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results frommore » the diagnostic are presented.« less

  14. A preterm infant with intestinal lymphangiectasia: a diagnostic dilemma.

    PubMed

    McDonald, Karen Q; Bears, Christina M

    2009-01-01

    Intestinal lymphangiectasia (IL) is a potentially fatal disorder of the lymphatic system if it is not recognized and proper treatment initiated. The disease is characterized by lymphocytopenia, peripheral edema, and hypoalbuminemia. Because IL is a rare disease, the symptoms, diagnostic workup, and treatment are unfamiliar to many clinicians. Current literature documents only a few reported cases of IL in a preterm infant. This case report of a preterm infant reviews history, symptomatology, and the diagnostic workup performed. The steps in making the diagnosis, the treatment, and the prognosis of this condition are also presented.

  15. Addressing the Real-World Challenges in the Development of Propulsion IVHM Technology Experiment (PITEX)

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Chicatelli, Amy; Fulton, Christopher E.; Balaban, Edward; Sweet, Adam; Hayden, Sandra Claire; Bajwa, Anupa

    2005-01-01

    The Propulsion IVHM Technology Experiment (PITEX) has been an on-going research effort conducted over several years. PITEX has developed and applied a model-based diagnostic system for the main propulsion system of the X-34 reusable launch vehicle, a space-launch technology demonstrator. The application was simulation-based using detailed models of the propulsion subsystem to generate nominal and failure scenarios during captive carry, which is the most safety-critical portion of the X-34 flight. Since no system-level testing of the X-34 Main Propulsion System (MPS) was performed, these simulated data were used to verify and validate the software system. Advanced diagnostic and signal processing algorithms were developed and tested in real-time on flight-like hardware. In an attempt to expose potential performance problems, these PITEX algorithms were subject to numerous real-world effects in the simulated data including noise, sensor resolution, command/valve talkback information, and nominal build variations. The current research has demonstrated the potential benefits of model-based diagnostics, defined the performance metrics required to evaluate the diagnostic system, and studied the impact of real-world challenges encountered when monitoring propulsion subsystems.

  16. A systems engineering approach to automated failure cause diagnosis in space power systems

    NASA Technical Reports Server (NTRS)

    Dolce, James L.; Faymon, Karl A.

    1987-01-01

    Automatic failure-cause diagnosis is a key element in autonomous operation of space power systems such as Space Station's. A rule-based diagnostic system has been developed for determining the cause of degraded performance. The knowledge required for such diagnosis is elicited from the system engineering process by using traditional failure analysis techniques. Symptoms, failures, causes, and detector information are represented with structured data; and diagnostic procedural knowledge is represented with rules. Detected symptoms instantiate failure modes and possible causes consistent with currently held beliefs about the likelihood of the cause. A diagnosis concludes with an explanation of the observed symptoms in terms of a chain of possible causes and subcauses.

  17. Mesoscopic Vortex–Meissner currents in ring ladders

    NASA Astrophysics Data System (ADS)

    Haug, Tobias; Amico, Luigi; Dumke, Rainer; Kwek, Leong-Chuan

    2018-07-01

    Recent experimental progress have revealed Meissner and Vortex phases in low-dimensional ultracold atoms systems. Atomtronic setups can realize ring ladders, while explicitly taking the finite size of the system into account. This enables the engineering of quantized chiral currents and phase slips in between them. We find that the mesoscopic scale modifies the current. Full control of the lattice configuration reveals a reentrant behavior of Vortex and Meissner phases. Our approach allows a feasible diagnostic of the currents’ configuration through time-of-flight measurements.

  18. An intelligent control system for rocket engines - Need, vision, and issues

    NASA Technical Reports Server (NTRS)

    Lorenzo, Carl F.; Merrill, Walter C.

    1991-01-01

    Several components of intelligence are defined. Within the context of these definitions an intelligent control system for rocket engines is described. The description includes a framework for development of an intelligent control system, including diagnostics, coordination, and direct control. Some current results and issues are presented.

  19. Design and development of a simple UV fluorescence multi-spectral imaging system

    NASA Astrophysics Data System (ADS)

    Tovar, Carlos; Coker, Zachary; Yakovlev, Vladislav V.

    2018-02-01

    Healthcare access in low-resource settings is compromised by the availability of affordable and accurate diagnostic equipment. The four primary poverty-related diseases - AIDS, pneumonia, malaria, and tuberculosis - account for approximately 400 million annual deaths worldwide as of 2016 estimates. Current diagnostic procedures for these diseases are prolonged and can become unreliable under various conditions. We present the development of a simple low-cost UV fluorescence multi-spectral imaging system geared towards low resource settings for a variety of biological and in-vitro applications. Fluorescence microscopy serves as a useful diagnostic indicator and imaging tool. The addition of a multi-spectral imaging modality allows for the detection of fluorophores within specific wavelength bands, as well as the distinction between fluorophores possessing overlapping spectra. The developed instrument has the potential for a very diverse range of diagnostic applications in basic biomedical science and biomedical diagnostics and imaging. Performance assessment of the microscope will be validated with a variety of samples ranging from organic compounds to biological samples.

  20. Evaluation of thermal helium beam and line-ratio fast diagnostic on the National Spherical Torus Experiment-Upgrade

    DOE PAGES

    Munoz Burgos, Jorge M.; Agostini, Matteo; Scarin, Paolo; ...

    2015-05-06

    A 1-D kinetic collisional radiative model (CRM) with state-of-the-art atomic data is developed and employed to simulate line emission to evaluate the Thermal Helium Beam (THB) diagnostic on NSTX-U. This diagnostic is currently in operation on RFX-mod, and it is proposed to be installed on NSTX-U. The THB system uses the intensity ratios of neutral helium lines 667.8, 706.5, and 728.1 nm to derive electron temperature (eV ) and density (cm –3) profiles. The purpose of the present analysis is to evaluate the applications of this diagnostic for determining fast (~4 μs) electron temperature and density radial profiles on themore » scrape-off layer (SOL) and edge regions of NSTX-U that are needed in turbulence studies. The diagnostic is limited by the level of detection of the 728.1 nm line, which is the weakest of the three. In conclusion, this study will also aid in future design of a similar 2-D diagnostic systems on the divertor.« less

  1. Cognitive impairment in schizophrenia and affective psychoses: implications for DSM-V criteria and beyond.

    PubMed

    Bora, Emre; Yücel, Murat; Pantelis, Christos

    2010-01-01

    It has recently been suggested that the diagnostic criteria of schizophrenia should include specific reference to cognitive impairments characterizing the disorder. Arguments in support of this assertion contend that such inclusion would not only serve to increase the awareness of cognitive deficits in affected patients, among both clinicians and researchers alike, but also increase the "point of rarity" between schizophrenia and mood disorders. The aim of the current article is to examine this latter assertion in light of the recent opinion piece provided by Keefe and Fenton (Keefe RSE, Fenton WS. How should DSM-V criteria for schizophrenia include cognitive impairment? Schizophr Bull. 2007;33:912-920). Through literature review, we explore the issue of whether cognitive deficits do in fact differentiate the major psychoses. The overall results of this inquiry suggest that inclusion of cognitive impairment criteria in Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) (DSM-V) would not provide a major advancement in discriminating schizophrenia from bipolar disorder and affective psychoses. Therefore, while cognitive impairment should be included in DSM-V, it should not dictate diagnostic specificity--at least not until more comprehensive evidence-based reviews of the current diagnostic system have been undertaken. Based on this evidence, we consider several alternatives for the DSM-V definition of cognitive impairment in schizophrenia, including (1) the inclusion of cognitive impairment as a specifier and (2) the definition of cognitive impairment as a dimension within a hybrid categorical-dimensional system. Given the state of current evidence, these possibilities appear to represent the most parsimonious approaches to the inclusion of cognitive deficits in the diagnostic criteria of schizophrenia and, potentially, of mood disorders.

  2. Gene expression-based molecular diagnostic system for malignant gliomas is superior to histological diagnosis.

    PubMed

    Shirahata, Mitsuaki; Iwao-Koizumi, Kyoko; Saito, Sakae; Ueno, Noriko; Oda, Masashi; Hashimoto, Nobuo; Takahashi, Jun A; Kato, Kikuya

    2007-12-15

    Current morphology-based glioma classification methods do not adequately reflect the complex biology of gliomas, thus limiting their prognostic ability. In this study, we focused on anaplastic oligodendroglioma and glioblastoma, which typically follow distinct clinical courses. Our goal was to construct a clinically useful molecular diagnostic system based on gene expression profiling. The expression of 3,456 genes in 32 patients, 12 and 20 of whom had prognostically distinct anaplastic oligodendroglioma and glioblastoma, respectively, was measured by PCR array. Next to unsupervised methods, we did supervised analysis using a weighted voting algorithm to construct a diagnostic system discriminating anaplastic oligodendroglioma from glioblastoma. The diagnostic accuracy of this system was evaluated by leave-one-out cross-validation. The clinical utility was tested on a microarray-based data set of 50 malignant gliomas from a previous study. Unsupervised analysis showed divergent global gene expression patterns between the two tumor classes. A supervised binary classification model showed 100% (95% confidence interval, 89.4-100%) diagnostic accuracy by leave-one-out cross-validation using 168 diagnostic genes. Applied to a gene expression data set from a previous study, our model correlated better with outcome than histologic diagnosis, and also displayed 96.6% (28 of 29) consistency with the molecular classification scheme used for these histologically controversial gliomas in the original article. Furthermore, we observed that histologically diagnosed glioblastoma samples that shared anaplastic oligodendroglioma molecular characteristics tended to be associated with longer survival. Our molecular diagnostic system showed reproducible clinical utility and prognostic ability superior to traditional histopathologic diagnosis for malignant glioma.

  3. Diagnostics for Magnetically Driven Implosions on the 1-MA MAIZE Facility

    NASA Astrophysics Data System (ADS)

    Campbell, Paul; Yager-Elorriaga, David; Miller, Stephanie; Woolstrum, Jeff; Jones, Michael; Jordan, Nicholas; Lau, Y. Y.; Gilgenbach, Ronald; McBride, Ryan

    2017-10-01

    The Michigan Accelerator for Inductive Z-pinch Experiments (MAIZE) is a 3-m-diameter Linear Transformer Driver (LTD) at the University of Michigan which supplies a fast electrical pulse (0-1 MA in 100 ns, for matched loads) to various experimental configurations. In order to better investigate these loads, new diagnostics are being developed. First, an EUV/XUV micro-channel plate pinhole camera and a UV laser imaging system are being implemented to better observe the instability structures that form during implosions. Second, an x-pinch radiography diagnostic is being developed to probe deeper into the plasma loads. Third, Rogowski coils are being developed for enhanced load current measurements. Finally, a bolometry system and photo-conducting diamond (PCD) detectors will be implemented to measure x-ray power and energy. These new systems, combined with the existing twelve-frame laser shadowgraphy, and b-dot current monitors, will be powerful tools for the investigation of imploding z-pinch experiments. This research was supported by the DOE through award DE-SC0012328, Sandia National Laboratories contract DE-NA0003525, the National Science Foundation, and a Nuclear Regulatory Commission new-faculty development Grant. D.Y.E. was supported by an NSF fello.

  4. Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.

    2004-01-01

    The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

  5. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-01-01

    Introduction With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. Materials and methods In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Results Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Conclusions Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia. PMID:27812306

  6. A meta-analysis of use of Prostate Imaging Reporting and Data System Version 2 (PI-RADS V2) with multiparametric MR imaging for the detection of prostate cancer.

    PubMed

    Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi

    2017-12-01

    This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.

  7. Metabolomics for laboratory diagnostics.

    PubMed

    Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman

    2015-09-10

    Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited).

    PubMed

    Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H

    2010-10-01

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  9. Lithium Battery Transient Response as a Diagnostic Tool

    NASA Astrophysics Data System (ADS)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  10. Climate Model Diagnostic Analyzer Web Service System

    NASA Astrophysics Data System (ADS)

    Lee, S.; Pan, L.; Zhai, C.; Tang, B.; Kubar, T. L.; Li, J.; Zhang, J.; Wang, W.

    2015-12-01

    Both the National Research Council Decadal Survey and the latest Intergovernmental Panel on Climate Change Assessment Report stressed the need for the comprehensive and innovative evaluation of climate models with the synergistic use of global satellite observations in order to improve our weather and climate simulation and prediction capabilities. The abundance of satellite observations for fundamental climate parameters and the availability of coordinated model outputs from CMIP5 for the same parameters offer a great opportunity to understand and diagnose model biases in climate models. In addition, the Obs4MIPs efforts have created several key global observational datasets that are readily usable for model evaluations. However, a model diagnostic evaluation process requires physics-based multi-variable comparisons that typically involve large-volume and heterogeneous datasets, making them both computationally- and data-intensive. In response, we have developed a novel methodology to diagnose model biases in contemporary climate models and implementing the methodology as a web-service based, cloud-enabled, provenance-supported climate-model evaluation system. The evaluation system is named Climate Model Diagnostic Analyzer (CMDA), which is the product of the research and technology development investments of several current and past NASA ROSES programs. The current technologies and infrastructure of CMDA are designed and selected to address several technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. In particular, we have three key technology components: (1) diagnostic analysis methodology; (2) web-service based, cloud-enabled technology; (3) provenance-supported technology. The diagnostic analysis methodology includes random forest feature importance ranking, conditional probability distribution function, conditional sampling, and time-lagged correlation map. We have implemented the new methodology as web services and incorporated the system into the Cloud. We have also developed a provenance management system for CMDA where CMDA service semantics modeling, service search and recommendation, and service execution history management are designed and implemented.

  11. Methods for Fault Detection, Diagnostics and Prognostics for Building Systems - A Review Part I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katipamula, Srinivas; Brambley, Michael R.

    This paper provides an overview of fault detection, diagnostics, and prognostics (FDD&P) starting with descriptions of the fundamental processes and some important definitions. This is followed by a review of FDD&P research in the HVAC&R field, and the paper concludes with discussions of the current state of applications in buildings and likely contributions to operating and maintaining buildings in the future.

  12. A Proposal for a Dimensional Classification System Based on the Shared Features of the "DSM-IV" Anxiety and Mood Disorders: Implications for Assessment and Treatment

    ERIC Educational Resources Information Center

    Brown, Timothy A.; Barlow, David H.

    2009-01-01

    A wealth of evidence attests to the extensive current and lifetime diagnostic comorbidity of the "Diagnostic and Statistical Manual of Mental Disorders" (4th ed., "DSM-IV") anxiety and mood disorders. Research has shown that the considerable cross-sectional covariation of "DSM-IV" emotional disorders is accounted for by common higher order…

  13. FPGA based charge acquisition algorithm for soft x-ray diagnostics system

    NASA Astrophysics Data System (ADS)

    Wojenski, A.; Kasprowicz, G.; Pozniak, K. T.; Zabolotny, W.; Byszuk, A.; Juszczyk, B.; Kolasinski, P.; Krawczyk, R. D.; Zienkiewicz, P.; Chernyshova, M.; Czarski, T.

    2015-09-01

    Soft X-ray (SXR) measurement systems working in tokamaks or with laser generated plasma can expect high photon fluxes. Therefore it is necessary to focus on data processing algorithms to have the best possible efficiency in term of processed photon events per second. This paper refers to recently designed algorithm and data-flow for implementation of charge data acquisition in FPGA. The algorithms are currently on implementation stage for the soft X-ray diagnostics system. In this paper despite of the charge processing algorithm is also described general firmware overview, data storage methods and other key components of the measurement system. The simulation section presents algorithm performance and expected maximum photon rate.

  14. Time-resolved energy spectrum measurement of a linear induction accelerator with the magnetic analyzer

    NASA Astrophysics Data System (ADS)

    Wang, Yuan; Jiang, Xiao-Guo; Yang, Guo-Jun; Chen, Si-Fu; Zhang, Zhuo; Wei, Tao; Li, Jin

    2015-01-01

    We recently set up a time-resolved optical beam diagnostic system. Using this system, we measured the high current electron beam energy in the accelerator under construction. This paper introduces the principle of the diagnostic system, describes the setup, and shows the results. A bending beam line was designed using an existing magnetic analyzer with a 300 mm-bending radius and a 60° bending angle at hard-edge approximation. Calculations show that the magnitude of the beam energy is about 18 MeV, and the energy spread is within 2%. Our results agree well with the initial estimates deduced from the diode voltage approach.

  15. Air Breathing Propulsion Controls and Diagnostics Research at NASA Glenn Under NASA Aeronautics Research Mission Programs

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2014-01-01

    This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

  16. A tangentially viewing fast ion D-alpha diagnostic for NSTX.

    PubMed

    Bortolon, A; Heidbrink, W W; Podestà, M

    2010-10-01

    A second fast ion D-alpha (FIDA) installation is planned at NSTX to complement the present perpendicular viewing FIDA diagnostics. Following the present diagnostic scheme, the new diagnostic will consist of two instruments: a spectroscopic diagnostic that measures fast ion spectra and profiles at 16 radial points with 5-10 ms resolution and a system that uses a band pass filter and photomultiplier to measure changes in FIDA light with 50 kHz sampling rate. The new pair of FIDA instruments will view the heating beams tangentially. The viewing geometry minimizes spectral contamination by beam emission or edge sources of background emission. The improved velocity-space resolution will provide detailed information about neutral-beam current drive and about fast ion acceleration and transport by injected radio frequency waves and plasma instabilities.

  17. Gynecologic electrical impedance tomograph

    NASA Astrophysics Data System (ADS)

    Korjenevsky, A.; Cherepenin, V.; Trokhanova, O.; Tuykin, T.

    2010-04-01

    Electrical impedance tomography extends to the new and new areas of the medical diagnostics: lungs, breast, prostate, etc. The feedback from the doctors who use our breast EIT diagnostic system has induced us to develop the 3D electrical impedance imaging device for diagnostics of the cervix of the uterus - gynecologic impedance tomograph (GIT). The device uses the same measuring approach as the breast imaging system: 2D flat array of the electrodes arranged on the probe with handle is placed against the body. Each of the 32 electrodes of the array is connected in turn to the current source while the rest electrodes acquire the potentials on the surface. The current flows through the electrode of the array and returns through the remote electrode placed on the patient's limb. The voltages are measured relative to another remote electrode. The 3D backprojection along equipotential surfaces is used to reconstruct conductivity distribution up to approximately 1 cm in depth. Small number of electrodes enables us to implement real time imaging with a few frames per sec. rate. The device is under initial testing and evaluation of the imaging capabilities and suitability of usage.

  18. A NEW HEALTH TECHNOLOGY ASSESSMENT SYSTEM FOR DEVICES: THE FIRST FIVE YEARS.

    PubMed

    Campbell, Bruce; Dobson, Lee; Higgins, Joanne; Dillon, Bernice; Marlow, Mirella; Pomfrett, Chris

    2017-01-01

    The aim of this study was to review 5 years of activity from a new system devised by the National Institute for Health and Care Excellence (NICE), for assessing medical devices and diagnostics aimed at identifying and speeding adoption of technologies with clinical and cost advantages, compared with current practice in the United Kingdom healthcare system. All eligible notified technologies were classified using the Food and Drug Administration and Global Medical Device Nomenclature nomenclatures. Decisions about selecting technologies for full assessment to produce NICE recommendations were reviewed, along with the reasons given to companies for not selecting products. Between 2009 and 2014, 186 technologies were notified (46 percent therapeutic and 54 percent diagnostic). Thirty-nine were judged ineligible (no regulatory approval), and 147 were considered by an independent committee. Of these, eighty (54 percent) were not selected for full assessment, most commonly because of insufficient evidence (86 percent): there were uncertainties specifically about benefits to the health service (54 percent), to patients (39 percent), and about cost (24 percent). The remaining 67 were selected and assessed for Medical Technology guidance (52 percent) (noninferior and/or lower cost consequences than current practice), for Diagnostics guidance (43 percent) or other NICE recommendations about adoption and use. Classifying technologies by two different systems showed no selection bias for any technology type or disease area. Identifying new or under-used devices and diagnostics with potential benefits and promoting their adoption is important to health services in the United Kingdom and worldwide. This new system offers a means of fostering both uptake and further research. Lack of research data on new products is a major obstacle to evaluation.

  19. Design and implementation of a status at a glance user interface for a power distribution expert system

    NASA Technical Reports Server (NTRS)

    Liberman, Eugene M.; Manner, David B.; Dolce, James L.; Mellor, Pamela A.

    1993-01-01

    A user interface to the power distribution expert system for Space Station Freedom is discussed. The importance of features which simplify assessing system status and which minimize navigating through layers of information are examined. Design rationale and implementation choices are also presented. The amalgamation of such design features as message linking arrows, reduced information content screens, high salience anomaly icons, and color choices with failure detection and diagnostic explanation from an expert system is shown to provide an effective status-at-a-glance monitoring system for power distribution. This user interface design offers diagnostic reasoning without compromising the monitoring of current events. The display can convey complex concepts in terms that are clear to its users.

  20. Systemic lupus erythematosus diagnostics in the ‘omics’ era

    PubMed Central

    Arriens, Cristina; Mohan, Chandra

    2014-01-01

    Systemic lupus erythematosus is a complex autoimmune disease affecting multiple organ systems. Currently, diagnosis relies upon meeting at least four out of eleven criteria outlined by the ACR. The scientific community actively pursues discovery of novel diagnostics in the hope of better identifying susceptible individuals in early stages of disease. Comprehensive studies have been conducted at multiple biological levels including: DNA (or genomics), mRNA (or transcriptomics), protein (or proteomics) and metabolites (or metabolomics). The ‘omics’ platforms allow us to re-examine systemic lupus erythematosus at a greater degree of molecular resolution. More importantly, one is hopeful that these ‘omics’ platforms may yield newer biomarkers for systemic lupus erythematosus that can help clinicians track the disease course with greater sensitivity and specificity. PMID:24860621

  1. A Research Agenda for Malaria Eradication: Diagnoses and Diagnostics

    PubMed Central

    2011-01-01

    Many of malaria's signs and symptoms are indistinguishable from those of other febrile diseases. Detection of the presence of Plasmodium parasites is essential, therefore, to guide case management. Improved diagnostic tools are required to enable targeted treatment of infected individuals. In addition, field-ready diagnostic tools for mass screening and surveillance that can detect asymptomatic infections of very low parasite densities are needed to monitor transmission reduction and ensure elimination. Antibody-based tests for infection and novel methods based on biomarkers need further development and validation, as do methods for the detection and treatment of Plasmodium vivax. Current rapid diagnostic tests targeting P. vivax are generally less effective than those targeting Plasmodium falciparum. Moreover, because current drugs for radical cure may cause serious side effects in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency, more information is needed on the distribution of G6PD-deficiency variants as well as tests to identify at-risk individuals. Finally, in an environment of very low or absent malaria transmission, sustaining interest in elimination and maintaining resources will become increasingly important. Thus, research is required into the context in which malaria diagnostic tests are used, into diagnostics for other febrile diseases, and into the integration of these tests into health systems. PMID:21311583

  2. Acute diagnostic biomarkers for spinal cord injury: review of the literature and preliminary research report.

    PubMed

    Yokobori, Shoji; Zhang, Zhiqun; Moghieb, Ahmed; Mondello, Stefania; Gajavelli, Shyam; Dietrich, W Dalton; Bramlett, Helen; Hayes, Ronald L; Wang, Michael; Wang, Kevin K W; Bullock, M Ross

    2015-05-01

    Many efforts have been made to create new diagnostic technologies for use in the diagnosis of central nervous system injury. However, there is still no consensus for the use of biomarkers in clinical acute spinal cord injury (SCI). The aims of this review are (1) to evaluate the current status of neurochemical biomarkers and (2) to discuss their potential acute diagnostic role in SCI by reviewing the literature. PubMed (http://www.ncbi.nlm.nih.gov/pubmed) was searched up to 2012 to identify publications concerning diagnostic biomarkers in SCI. To support more knowledge, we also checked secondary references in the primarily retrieved literature. Neurofilaments, cleaved-Tau, microtubule-associated protein 2, myelin basic protein, neuron-specific enolase, S100β, and glial fibrillary acidic protein were identified as structural protein biomarkers in SCI by this review process. We could not find reports relating ubiquitin C-terminal hydrolase-L1 and α-II spectrin breakdown products, which are widely researched in other central nervous system injuries. Therefore, we present our preliminary data relating to these two biomarkers. Some of biomarkers showed promising results for SCI diagnosis and outcome prediction; however, there were unresolved issues relating to accuracy and their accessibility. Currently, there still are not many reports focused on diagnostic biomarkers in SCI. This fact warranted the need for greater efforts to innovate sensitive and reliable biomarkers for SCI. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. How to diagnose neuropathic pain? The contribution from clinical examination, pain questionnaires and diagnostic tests.

    PubMed

    La Cesa, S; Tamburin, S; Tugnoli, V; Sandrini, G; Paolucci, S; Lacerenza, M; Marchettini, P; Cruccu, G; Truini, A

    2015-12-01

    Patients with peripheral and central nervous system diseases may suffer from different types of pain, namely nociceptive, neuropathic and mixed pain. Although in some cases, the distinction between these types of pain is clinically evident, yet in some patients an accurate differential diagnosis requires dedicated clinical examination, screening questionnaires and diagnostic techniques some of which are available only in specialized pain centres. This review briefly addresses the currently agreed definitions of the different types of pain and shows how clinical examination, pain questionnaires and diagnostic tests can help the clinicians in identifying neuropathic pain.

  4. Optimization of Antenna Current Feeding for the Alfvén Eigenmodes Active Diagnostic System of JET

    NASA Astrophysics Data System (ADS)

    Albarracin Manrique, Marcos A.; Ruchko, L.; Pires, C. J. A.; Galvão, R. M. O.; Elfimov, A. G.

    2018-04-01

    The possibility of exploring proper phasing of the feeding currents in the existing antenna of the Alfvén Eigenmodes Active Diagnostic system of JET, to excite pure toroidal spectra of Toroidal Alfvén Eigenmodes, is numerically investigated. Special attention is given to the actual perturbed fields excited in the plasma, which are calculated self-consistently using the antenna version of the CASTOR code. It is found that due to the close spacing of the JET antenna modules and quasi degeneracy of modes with medium to high values of the toroidal mode number n, although a proper choice of the phasing of the feeding currents of the antenna modules indeed leads to an increase of the perturbed fields of the selected mode, modes with nearby values of n are also excited with large amplitudes, so that a scheme to proper select the detected modes remains necessary. A scheme using different antenna position distribution is proposed to achieve successful optimization.

  5. Hyperspectral fluorescence imaging system for biomedical diagnostics

    NASA Astrophysics Data System (ADS)

    Martin, Matthew E.; Wabuyele, Musundi B.; Panjehpour, Masoud; Phan, Mary N.; Overholt, Bergein F.; Vo-Dinh, Tuan

    2006-02-01

    An advanced hyper-spectral imaging (HSI) system has been developed for use in medical diagnostics. One such diagnostic, esophageal cancer is diagnosed currently through biopsy and subsequent pathology. The end goal of this research is to develop an optical-based technique to assist or replace biopsy. In this paper, we demonstrate an instrument that has the capability to optically diagnose cancer in laboratory mice. We have developed a real-time HSI system based on state-of-the-art liquid crystal tunable filter (LCTF) technology coupled to an endoscope. This unique HSI technology is being developed to obtain spatially resolved images of the slight differences in luminescent properties of normal versus tumorous tissues. In this report, an in-vivo mouse study is shown. A predictive measure of cancer for the mice studied is developed and shown. It is hoped that the results of this study will lead to advances in the optical diagnosis of esophageal cancer in humans.

  6. Detection of inter-turn faults in transformer winding using the capacitor discharge method

    NASA Astrophysics Data System (ADS)

    Michna, Michał; Wilk, Andrzej; Ziółko, Michał; Wołoszyk, Marek; Swędrowski, Leon; Szwangruber, Piotr

    2017-12-01

    The paper presents results of an analysis of inter-turn fault effects on the voltage and current waveforms of a capacitor discharge through transformer windings. The research was conducted in the frame of the Facility of Antiproton and Ion Research project which goal is to build a new international accelerator facility that utilizes superconducting magnets. For the sake of electrical quality assurance of the superconducting magnet circuits, a measurement and diagnostic system is currently under development at Gdansk University of Technology (GUT). Appropriate measurements and simulations of the special transformer system were performed to verify the proposed diagnostic method. In order to take into account the nonlinearity and hysteresis of the magnetic yoke, a novel mathematical model of the transformer was developed. A special test bench was constructed to emulate the inter-turn faults within transformer windings.

  7. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  8. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD

    PubMed Central

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B.; Bramsen, Rikke H.; Nielsen, Anni B. S.; Armour, Cherie; Andersen, Søren B.; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E.

    2017-01-01

    ABSTRACT Background: Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives: The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students (N = 4213), chronic pain patients (N = 573), and military personnel (N = 118). Results: Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions: The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD. PMID:29201287

  9. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD.

    PubMed

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B; Bramsen, Rikke H; Nielsen, Anni B S; Armour, Cherie; Andersen, Søren B; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E

    2017-01-01

    Background : Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives : The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students ( N  = 4213), chronic pain patients ( N  = 573), and military personnel ( N  = 118). Results : Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions : The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD.

  10. Microfluidic paper-based analytical devices for potential use in quantitative and direct detection of disease biomarkers in clinical analysis.

    PubMed

    Lim, Wei Yin; Goh, Boon Tong; Khor, Sook Mei

    2017-08-15

    Clinicians, working in the health-care diagnostic systems of developing countries, currently face the challenges of rising costs, increased number of patient visits, and limited resources. A significant trend is using low-cost substrates to develop microfluidic devices for diagnostic purposes. Various fabrication techniques, materials, and detection methods have been explored to develop these devices. Microfluidic paper-based analytical devices (μPADs) have gained attention for sensing multiplex analytes, confirming diagnostic test results, rapid sample analysis, and reducing the volume of samples and analytical reagents. μPADs, which can provide accurate and reliable direct measurement without sample pretreatment, can reduce patient medical burden and yield rapid test results, aiding physicians in choosing appropriate treatment. The objectives of this review are to provide an overview of the strategies used for developing paper-based sensors with enhanced analytical performances and to discuss the current challenges, limitations, advantages, disadvantages, and future prospects of paper-based microfluidic platforms in clinical diagnostics. μPADs, with validated and justified analytical performances, can potentially improve the quality of life by providing inexpensive, rapid, portable, biodegradable, and reliable diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Methods for Fault Detection, Diagnostics and Prognostics for Building Systems - A Review Part II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katipamula, Srinivas; Brambley, Michael R.

    This paper provides the second part of an overview of fault detection, diagnostics, and prognostics (FDD&P) starting with descriptions of the fundamental processes and some important definitions. This is followed by a review of FDD&P research in the HVAC&R field, and the paper concludes with discussions of the current state of applications in buildings and likely contributions to operating and maintaining buildings in the future.

  12. Diagnostics monitor of the braking efficiency in the on board diagnostics system for the motor vehicles

    NASA Astrophysics Data System (ADS)

    Gajek, Andrzej

    2016-09-01

    The article presents diagnostics monitor for control of the efficiency of brakes in various road conditions in cars equipped with pressure sensor in brake (ESP) system. Now the brake efficiency of the vehicles is estimated periodically in the stand conditions on the base of brake forces measurement or in the road conditions on the base of the brake deceleration. The presented method allows to complete the stand - periodical tests of the brakes by current on board diagnostics system OBD for brakes. First part of the article presents theoretical dependences between deceleration of the vehicle and brake pressure. The influence of the vehicle mass, initial speed of braking, temperature of brakes, aerodynamic drag, rolling resistance, engine resistance, state of the road surface, angle of the road sloping on the deceleration have been analysed. The manner of the appointed of these parameters has been analysed. The results of the initial investigation have been presented. At the end of the article the strategy of the estimation and signalization of the irregular value of the deceleration are presented.

  13. Status of US ITER Diagnostics

    NASA Astrophysics Data System (ADS)

    Stratton, B.; Delgado-Aparicio, L.; Hill, K.; Johnson, D.; Pablant, N.; Barnsley, R.; Bertschinger, G.; de Bock, M. F. M.; Reichle, R.; Udintsev, V. S.; Watts, C.; Austin, M.; Phillips, P.; Beiersdorfer, P.; Biewer, T. M.; Hanson, G.; Klepper, C. C.; Carlstrom, T.; van Zeeland, M. A.; Brower, D.; Doyle, E.; Peebles, A.; Ellis, R.; Levinton, F.; Yuh, H.

    2013-10-01

    The US is providing 7 diagnostics to ITER: the Upper Visible/IR cameras, the Low Field Side Reflectometer, the Motional Stark Effect diagnostic, the Electron Cyclotron Emission diagnostic, the Toroidal Interferometer/Polarimeter, the Core Imaging X-Ray Spectrometer, and the Diagnostic Residual Gas Analyzer. The front-end components of these systems must operate with high reliability in conditions of long pulse operation, high neutron and gamma fluxes, very high neutron fluence, significant neutron heating (up to 7 MW/m3) , large radiant and charge exchange heat flux (0.35 MW/m2) , and high electromagnetic loads. Opportunities for repair and maintenance of these components will be limited. These conditions lead to significant challenges for the design of the diagnostics. Space constraints, provision of adequate radiation shielding, and development of repair and maintenance strategies are challenges for diagnostic integration into the port plugs that also affect diagnostic design. The current status of design of the US ITER diagnostics is presented and R&D needs are identified. Supported by DOE contracts DE-AC02-09CH11466 (PPPL) and DE-AC05-00OR22725 (UT-Battelle, LLC).

  14. Current trends from the USDA influenza a virus in swine surveillance system

    USDA-ARS?s Scientific Manuscript database

    A U.S. national surveillance system for influenza A viruses (IAV) in swine was initiated in 2009 with increasing participation to the present day. The objectives are to monitor genetic evolution of IAV in swine, make isolates available for research, diagnostic reagents, and vaccine development throu...

  15. Replacing Myalgic Encephalomyelitis and Chronic Fatigue Syndrome with Systemic Exercise Intolerance Disease Is Not the Way forward

    PubMed Central

    Twisk, Frank N.M.

    2016-01-01

    Myalgic encephalomyelitis (ME), described in the medical literature since 1938, is characterized by distinctive muscular symptoms, neurological symptoms, and signs of circulatory impairment. The only mandatory feature of chronic fatigue syndrome (CFS), introduced in 1988 and redefined in 1994, is chronic fatigue, which should be accompanied by at least four or more out of eight “additional” symptoms. The use of the abstract, polythetic criteria of CFS, which define a heterogeneous patient population, and self-report has hampered both scientific progress and accurate diagnosis. To resolve the “diagnostic impasse” the Institute of Medicine proposes that a new clinical entity, systemic exercise intolerance disease (SEID), should replace the clinical entities ME and CFS. However, adopting SEID and its defining symptoms, does not resolve methodological and diagnostic issues. Firstly, a new diagnostic entity cannot replace two distinct, partially overlapping, clinical entities such as ME and CFS. Secondly, due to the nature of the diagnostic criteria, the employment of self-report, and the lack of criteria to exclude patients with other conditions, the SEID criteria seem to select an even more heterogeneous patient population, causing additional diagnostic confusion. This article discusses methodological and diagnostic issues related to SEID and proposes a methodological solution for the current “diagnostic impasse”. PMID:26861399

  16. Towards diagnostic markers for the psychoses.

    PubMed

    Lawrie, Stephen M; O'Donovan, Michael C; Saks, Elyn; Burns, Tom; Lieberman, Jeffrey A

    2016-04-01

    Psychotic disorders are currently grouped under broad phenomenological diagnostic rubrics. Researchers hope that progress in identifying aetiological mechanisms will ultimately enable more precise division of heterogeneous diagnoses into specific and valid subgroups. This goal has been an aim of psychiatry since the 19th century, when patients with general paresis were thought to have "insanity" similar to dementia praecox and manic depressive illness. Nowadays, the constructs of organic-induced and substance-induced psychotic disorder show that our diagnostic classification system already reflects, in part, aetiological factors. Most recently, gene copy number variation and autoimmunity have been associated with schizophrenia. We suggest how, on the basis of recent scientific advances, we can progress the identification of further putative subgroups and make the most of currently available interventions. Prompt diagnosis and treatment, and a more routine search for causes, could preserve function and improve outcome, and therefore be more acceptable to patients and carers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Rocket engine exhaust plume diagnostics and health monitoring/management during ground testing

    NASA Technical Reports Server (NTRS)

    Chenevert, D. J.; Meeks, G. R.; Woods, E. G.; Huseonica, H. F.

    1992-01-01

    The current status of a rocket exhaust plume diagnostics program sponsored by NASA is reviewed. The near-term objective of the program is to enhance test operation efficiency and to provide for safe cutoff of rocket engines prior to incipient failure, thereby avoiding the destruction of the engine and the test complex and preventing delays in the national space program. NASA programs that will benefit from the nonintrusive remote sensed rocket plume diagnostics and related vehicle health management and nonintrusive measurement program are Space Shuttle Main Engine, National Launch System, National Aero-Space Plane, Space Exploration Initiative, Advanced Solid Rocket Motor, and Space Station Freedom. The role of emission spectrometry and other types of remote sensing in rocket plume diagnostics is discussed.

  18. Injector for the University of Maryland Electron Ring (UMER)

    NASA Astrophysics Data System (ADS)

    Kehne, D.; Godlove, T.; Haldemann, P.; Bernal, S.; Guharay, S.; Kishek, R.; Li, Y.; O'Shea, P.; Reiser, M.; Yun, V.; Zou, Y.; Haber, I.

    2001-05-01

    The electron beam injector constructed by FM technologies for the University of Maryland Electron Ring (UMER) program is described. The program will use an electron beam to model space-charge-dominated ion beams in a recirculating linac for heavy ion inertial fusion, as well as for high-current muon colliders. The injector consists of a 10 keV, 100 mA electron gun with 50-100 nsec pulse width and a repetition rate of 120 Hz. The e-gun system includes a 6-mask, rotatable aperture plate, a Rogowski current monitor, an ion pump, and a gate valve. The injector beamline consists of a solenoid, a five-quadrupole matching section, two diagnostic chambers, and a fast current monitor. An independent diagnostic chamber also built for UMER will be used to measure horizontal and vertical emittance, current, energy, energy spread, and the evolution of the beam envelope and profile along the injector beamline.

  19. Overview of ion source characterization diagnostics in INTF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bandyopadhyay, M., E-mail: mainak@iter-india.org; Sudhir, Dass; Bhuyan, M.

    2016-02-15

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction regionmore » will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.« less

  20. Overview of ion source characterization diagnostics in INTF

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, M.; Sudhir, Dass; Bhuyan, M.; Soni, J.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A.

    2016-02-01

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  1. Sub-nanosecond cinematography in laser fusion research: Current techniques and applications at the Lawrence Livermore Laboratory

    NASA Astrophysics Data System (ADS)

    Coleman, L. W.

    1985-01-01

    Progress in laser fusion research has increased the need for detail and precision in the diagnosis of experiments. This has spawned the development and use of sophisticated sub-nanosecond resolution diagnostic systems. These systems typically use ultrafast X-ray or optical streak cameras in combination with spatially imaging or spectrally dispersing elements. These instruments provide high resolution data essential for understanding the processes occurring in the interaction of high intensity laser light with targets. Several of these types of instruments and their capabilities will be discussed. The utilization of these kinds of diagnostics systems on the nearly completed 100 kJ Nova laser facility will be described.

  2. Utility of the Paris System in Reporting Urine Cytology.

    PubMed

    Malviya, Kiran; Fernandes, Gwendolyn; Naik, Leena; Kothari, Kanchan; Agnihotri, Mona

    2017-01-01

    To find out the utility of The Paris System (TPS) in reporting urine cytology and to compare it with the reporting system currently used in our laboratory. This retrospective study was undertaken over a period of 1 year during which slides of all the urine specimens sent for cytological examination were retrieved from our laboratory filling system. They were blindly reviewed and reclassified according to TPS. Surgical follow-up was obtained from the uropathology services of our department. A total of 176 cases were meticulously reviewed. The mean age of the patients was 52 years, and 71% of cases presented with hematuria. Histopathological follow-up was available in 34 cases. Reporting by TPS detected 13.0% high-grade urothelial carcinoma (HGUC) and 5.1% atypical urothelial cells versus 7.3 and 11.9% by the current reporting system, respectively. The sensitivity and diagnostic accuracy for detecting HGUC of TPS were higher than those of our reporting system. TPS has increased the rate of detection of HGUC and reduced the rate of reporting "atypical" urothelial cells. TPS has also standardized the diagnostic criteria, thereby bringing uniformity and reproducibility into the system of reporting for urine cytology. © 2017 S. Karger AG, Basel.

  3. Diagnosing Breast Cancer with Microwave Technology: remaining challenges and potential solutions with machine learning.

    PubMed

    Oliveira, Bárbara L; Godinho, Daniela; O'Halloran, Martin; Glavin, Martin; Jones, Edward; Conceição, Raquel C

    2018-05-19

    Currently, breast cancer often requires invasive biopsies for diagnosis, motivating researchers to design and develop non-invasive and automated diagnosis systems. Recent microwave breast imaging studies have shown how backscattered signals carry relevant information about the shape of a tumour, and tumour shape is often used with current imaging modalities to assess malignancy. This paper presents a comprehensive analysis of microwave breast diagnosis systems which use machine learning to learn characteristics of benign and malignant tumours. The state-of-the-art, the main challenges still to overcome and potential solutions are outlined. Specifically, this work investigates the benefit of signal pre-processing on diagnostic performance, and proposes a new set of extracted features that capture the tumour shape information embedded in a signal. This work also investigates if a relationship exists between the antenna topology in a microwave system and diagnostic performance. Finally, a careful machine learning validation methodology is implemented to guarantee the robustness of the results and the accuracy of performance evaluation.

  4. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy.

    PubMed

    Sun, Yang; Park, Jesung; Stephens, Douglas N; Jo, Javier A; Sun, Lei; Cannata, Jonathan M; Saroufeem, Ramez M G; Shung, K Kirk; Marcu, Laura

    2009-06-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 microm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque.

  5. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy

    PubMed Central

    Sun, Yang; Park, Jesung; Stephens, Douglas N.; Jo, Javier A.; Sun, Lei; Cannata, Jonathan M.; Saroufeem, Ramez M. G.; Shung, K. Kirk; Marcu, Laura

    2009-01-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 μm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque. PMID:19566223

  6. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy

    NASA Astrophysics Data System (ADS)

    Sun, Yang; Park, Jesung; Stephens, Douglas N.; Jo, Javier A.; Sun, Lei; Cannata, Jonathan M.; Saroufeem, Ramez M. G.; Shung, K. Kirk; Marcu, Laura

    2009-06-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 μm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque.

  7. Non-contact high resolution Bessel beam probe for diagnostic imaging of cornea and trabecular meshwork region in eye

    NASA Astrophysics Data System (ADS)

    Murukeshan, V. M.; Jesmond, Hong Xun J.; Shinoj, V. K.; Baskaran, M.; Tin, Aung

    2015-07-01

    Primary angle closure glaucoma is a major form of disease that causes blindness in Asia and worldwide. In glaucoma, irregularities in the ocular aqueous outflow system cause an elevation in intraocular pressure (IOP) with subsequent death of retinal ganglion cells, resulting in loss of vision. High resolution visualization of the iridocorneal angle region has great diagnostic value in understanding the disease condition which enables monitoring of surgical interventions that decrease IOP. None of the current diagnostic techniques such as goniophotography, ultrasound biomicroscopy (UBM), anterior segment optical coherence tomography (AS-OCT) and RetCam™ can image with molecular specificity and required spatial resolution that can delineate the trabecular meshwork structures. This paper in this context proposes new concepts and methodology using Bessel beams based illumination and imaging for such diagnostic ocular imaging applications. The salient features using Bessel beams instead of the conventional Gaussian beam, and the optimization challenges in configuring the probe system will be illustrated with porcine eye samples.

  8. Understanding diagnostic errors in medicine: a lesson from aviation

    PubMed Central

    Singh, H; Petersen, L A; Thomas, E J

    2006-01-01

    The impact of diagnostic errors on patient safety in medicine is increasingly being recognized. Despite the current progress in patient safety research, the understanding of such errors and how to prevent them is inadequate. Preliminary research suggests that diagnostic errors have both cognitive and systems origins. Situational awareness is a model that is primarily used in aviation human factors research that can encompass both the cognitive and the systems roots of such errors. This conceptual model offers a unique perspective in the study of diagnostic errors. The applicability of this model is illustrated by the analysis of a patient whose diagnosis of spinal cord compression was substantially delayed. We suggest how the application of this framework could lead to potential areas of intervention and outline some areas of future research. It is possible that the use of such a model in medicine could help reduce errors in diagnosis and lead to significant improvements in patient care. Further research is needed, including the measurement of situational awareness and correlation with health outcomes. PMID:16751463

  9. Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Smith, Kevin; Raulerson, David; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Brasche, Lisa

    2003-01-01

    Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

  10. DEB: A Diagnostic Experience Browser using similarity networks

    NASA Technical Reports Server (NTRS)

    Casadaban, Cyprian E.

    1990-01-01

    Diagnostic Experience Browser (DEB): a fusion of knowledge base and data base that allows users to examine only the data which is most useful to them is described. The system combines a data base of historical cases of diagnostic trouble-shooting experience with similarity networks. A menu-driven natural language interface receives input about the user's current problem. Similarity networks provide the user with references to past cases that are most similar or most related to those they now face. The user can then choose the case that is most pertinent and browse its full textual description which, in turn, may include references to other related cases.

  11. [Diagnosis and differential diagnostic features of gender identity disorder].

    PubMed

    Kórász, Krisztián; Simon, Lajos

    2008-01-01

    Gender identity disorder, or transsexualism as it is more commonly known, is a highly complex clinical entity. It is an identifiable and incapacitating disease which can be diagnosed and successfully treated by reassignment surgery. The diagnosis of gender identity disorder can be a difficult process. Transsexual patients will have to undergo extensive psychiatric assessment. The authors review the development of nosology of transsexualism. The current classification systems, symptoms and diagnostic features of gender identity disorders are discussed. The article also discusses differential diagnostic features, like intersex states, psychosis, transvestitism, autogynephilia, gynandromorphophilia, and self-amputation. The authors also discuss the problem of comorbidity, as well.

  12. Automated Diagnosis and Control of Complex Systems

    NASA Technical Reports Server (NTRS)

    Kurien, James; Plaunt, Christian; Cannon, Howard; Shirley, Mark; Taylor, Will; Nayak, P.; Hudson, Benoit; Bachmann, Andrew; Brownston, Lee; Hayden, Sandra; hide

    2007-01-01

    Livingstone2 is a reusable, artificial intelligence (AI) software system designed to assist spacecraft, life support systems, chemical plants, or other complex systems by operating with minimal human supervision, even in the face of hardware failures or unexpected events. The software diagnoses the current state of the spacecraft or other system, and recommends commands or repair actions that will allow the system to continue operation. Livingstone2 is an enhancement of the Livingstone diagnosis system that was flight-tested onboard the Deep Space One spacecraft in 1999. This version tracks multiple diagnostic hypotheses, rather than just a single hypothesis as in the previous version. It is also able to revise diagnostic decisions made in the past when additional observations become available. In such cases, Livingstone might arrive at an incorrect hypothesis. Re-architecting and re-implementing the system in C++ has increased performance. Usability has been improved by creating a set of development tools that is closely integrated with the Livingstone2 engine. In addition to the core diagnosis engine, Livingstone2 includes a compiler that translates diagnostic models written in a Java-like language into Livingstone2's language, and a broad set of graphical tools for model development.

  13. Catatonia among adolescents with Down syndrome: a review and 2 case reports.

    PubMed

    Jap, Shannon N; Ghaziuddin, Neera

    2011-12-01

    Catatonia is a relatively common condition with an estimated prevalence of 0.6% to 17% among youth with psychiatric disorders. Certain patient groups, such as those with autism, may be at a particularly high risk for catatonia. Most of the youth with catatonia are males with a diagnosis of a bipolar disorder. We describe here 2 adolescent females, both with Down syndrome, who presented with catatonia not accompanied by significant affective or psychotic symptoms or with a general medical condition. Both patients had functioned well until the onset of catatonic symptoms. In the current classification system used in the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, catatonia is described in association with schizophrenia, as a specifier of affective disorders or secondary to general medical conditions. The cases described here highlight the problem with this classification system when patients fail to meet any of the 3 diagnostic categories under which catatonia is currently described.

  14. Development and construction of a comprehensive set of research diagnostics for the FLARE user facility

    NASA Astrophysics Data System (ADS)

    Yoo, Jongsoo; Jara-Almonte, J.; Majeski, S.; Frank, S.; Ji, H.; Yamada, M.

    2016-10-01

    FLARE (Facility for Laboratory Reconnection Experiments) will be operated as a flexible user facility, and so a complete set of research diagnostics is under development, including magnetic probe arrays, Langmuir probes, Mach probes, spectroscopic probes, and a laser interferometer. In order to accommodate the various requirements of users, large-scale (1 m), variable resolution (0.5-4 cm) magnetic probes have been designed, and are currently being prototyped. Moreover, a fully fiber-coupled laser interferometer has been designed to measure the line-integrated electron density. This fiber-coupled interferometer system will reduce the complexity of alignment processes and minimize maintenance of the system. Finally, improvements to the electrostatic probes and spectroscopic probes currently used in the Magnetic Reconnection Experiment (MRX) are discussed. The specifications of other subsystems, such as integrators and digitizers, are also presented. This work is supported by DoE Contract No. DE-AC0209CH11466.

  15. [An update of the diagnostic coding system by the Spanish Society of Pediatric Emergencies].

    PubMed

    Benito Fernández, J; Luaces Cubells, C; Gelabert Colomé, G; Anso Borda, I

    2015-06-01

    The Quality Working Group of the Spanish Society of Pediatric Emergencies (SEUP) presents an update of the diagnostic coding list. The original list was prepared and published in Anales de Pediatría in 2000, being based on the International Coding system ICD-9-CM current at that time. Following the same methodology used at that time and based on the 2014 edition of the ICD-9-CM, 35 new codes have been added to the list, 15 have been updated, and a list of the most frequent references to trauma diagnoses in pediatrics have been provided. In the current list of diagnoses, SEUP reflects the significant changes that have taken place in Pediatric Emergency Services in the last decade. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  16. Rates of traumatization and psychopathology in criminal justice-involved women.

    PubMed

    Salina, Doreen D; Figge, Caleb; Ram, Daphna; Jason, Leonard A

    2017-01-01

    Prior research has consistently found disproportionate rates of traumatization and psychopathology in criminal justice-involved women. The current study aimed to characterize rates of traumatization, psychopathology, and diagnostic comorbidity in women involved with the justice system. Furthermore, this study examined the role of posttraumatic stress symptoms in the association between traumatic events and levels of self-esteem. Participants were 185 women from the Chicagoland area with current or previous (past 2 years) involvement with the criminal justice system. Results confirmed disproportionate rates of trauma experiences and psychopathology in this population, and logistic regression analyses indicated that rates of traumatization predicted diagnostic comorbidity. Analyses indicated an indirect effect of posttraumatic stress in the association between traumatic experiences and self-esteem. Findings highlight the importance of assessing and targeting both trauma experiences and posttraumatic stress in justice-involved women to optimize prevention and intervention efforts.

  17. An overview of serological tests currently available for laboratory diagnosis of parasitic infections.

    PubMed

    Fox, J C; Jordan, H E; Kocan, K M; George, T J; Mullins, S T; Barnett, C E; Glenn, B L; Cowell, R L

    1986-03-01

    Current methods and commercial test systems for the diagnosis of parasitic infections in both animals and humans are reviewed. Lists of test kits and their manufacturers are provided along with ordering information: the only commercially available test kits are for the diagnosis of toxoplasmosis in humans or animals and dirofilariasis (heartworm) in dogs. A partial list of diagnostic laboratories and the parasite tests they perform is also provided. Complete lists of diagnostic tests that could be obtained in the private sector are not available but would be useful. Two microfluorometric solid-phase assay systems are reviewed, and adaptations to custom assays for several kinds of parasites are briefly described. User problems in performing tests and interpreting results are stressed with emphasis placed on diagnosis of dirofilariasis in dogs. False-positive serology in dogs without heartworms and negative antibody responses in micro-filariae-positive animals are discussed with respect to proper interpretation of results.

  18. Can we estimate plasma density in ICP driver through electrical parameters in RF circuit?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bandyopadhyay, M., E-mail: mainak@iter-india.org; Sudhir, Dass, E-mail: dass.sudhir@iter-india.org; Chakraborty, A., E-mail: arunkc@iter-india.org

    2015-04-08

    To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveancemore » condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.« less

  19. Conversion-Integration of MSFC Nonlinear Signal Diagnostic Analysis Algorithms for Realtime Execution of MSFC's MPP Prototype System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1996-01-01

    NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, M. C., E-mail: mthompson@trialphaenergy.com; Gota, H.; Putvinski, S.

    The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions ofmore » the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.« less

  1. Application of nanotechnology in miniaturized systems and its use for advanced analytics and diagnostics - an updated review.

    PubMed

    Sandetskaya, Natalia; Allelein, Susann; Kuhlmeier, Dirk

    2013-12-01

    A combination of Micro-Electro-Mechanical Systems and nanoscale structures allows for the creation of novel miniaturized devices, which broaden the boundaries of the diagnostic approaches. Some materials possess unique properties at the nanolevel, which are different from those in bulk materials. In the last few years these properties became a focus of interest for many researchers, as well as methods of production, design and operation of the nanoobjects. Intensive research and development work resulted in numerous inventions exploiting nanotechnology in miniaturized systems. Modern technical and laboratory equipment allows for the precise control of such devices, making them suitable for sensitive and accurate detection of the analytes. The current review highlights recent patents in the field of nanotechnology in microdevices, applicable for medical, environmental or food analysis. The paper covers the structural and functional basis of such systems and describes specific embodiments in three principal branches: application of nanoparticles, nanofluidics, and nanosensors in the miniaturized systems for advanced analytics and diagnostics. This overview is an update of an earlier review article.

  2. Prostate cancer: predicting high-risk prostate cancer-a novel stratification tool.

    PubMed

    Buck, Jessica; Chughtai, Bilal

    2014-05-01

    Currently, numerous systems exist for the identification of high-risk prostate cancer, but few of these systems can guide treatment strategies. A new stratification tool that uses common diagnostic factors can help to predict outcomes after radical prostatectomy. The tool aids physicians in the identification of appropriate candidates for aggressive, local treatment.

  3. Development of a Prototype H-46 Helicopter Diagnostic Expert System.

    DTIC Science & Technology

    1987-09-01

    SQUADRON MAINTEN\\NCE: CURRENT PROCESS AND CA D S INTEG R ,ATIO N ........................................ 14 A. MAINTENANCE DATA SYSTEM...increasce the effectiveness of the maintenance process should enhance the ability of achieving :hee objectives. Artificial intelligence techniques offer a...completeiy validated. G. ORGANIZATION OF STUDY Chapter II contains a description of the Naval Aviation Maintenance Program’s Maintenance Data System (MDS

  4. Aircraft Turbine Engine Control Research at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2014-01-01

    This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

  5. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 7; Acquire Express-A3 SPT-100 Based Propulsion Subsystem and Other Subsystem Flight Operation TM-Data, Task 32

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  6. Develop Advanced Nonlinear Signal Analysis Topographical Mapping System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1997-01-01

    During the development of the SSME, a hierarchy of advanced signal analysis techniques for mechanical signature analysis has been developed by NASA and AI Signal Research Inc. (ASRI) to improve the safety and reliability for Space Shuttle operations. These techniques can process and identify intelligent information hidden in a measured signal which is often unidentifiable using conventional signal analysis methods. Currently, due to the highly interactive processing requirements and the volume of dynamic data involved, detailed diagnostic analysis is being performed manually which requires immense man-hours with extensive human interface. To overcome this manual process, NASA implemented this program to develop an Advanced nonlinear signal Analysis Topographical Mapping System (ATMS) to provide automatic/unsupervised engine diagnostic capabilities. The ATMS will utilize a rule-based Clips expert system to supervise a hierarchy of diagnostic signature analysis techniques in the Advanced Signal Analysis Library (ASAL). ASAL will perform automatic signal processing, archiving, and anomaly detection/identification tasks in order to provide an intelligent and fully automated engine diagnostic capability. The ATMS has been successfully developed under this contract. In summary, the program objectives to design, develop, test and conduct performance evaluation for an automated engine diagnostic system have been successfully achieved. Software implementation of the entire ATMS system on MSFC's OISPS computer has been completed. The significance of the ATMS developed under this program is attributed to the fully automated coherence analysis capability for anomaly detection and identification which can greatly enhance the power and reliability of engine diagnostic evaluation. The results have demonstrated that ATMS can significantly save time and man-hours in performing engine test/flight data analysis and performance evaluation of large volumes of dynamic test data.

  7. A new diagnostic method for separating airborne and structureborne noise radiated by plates with applications for propeller driven aircraft

    NASA Technical Reports Server (NTRS)

    Mcgary, Michael C.

    1988-01-01

    The anticipated application of advanced turboprop propulsion systems is expected to increase the interior noise of future aircraft to unacceptably high levels. The absence of technically and economically feasible noise source-path diagnostic tools has been a prime obstacle in the development of efficient noise control treatments for propeller-driven aircraft. A new diagnostic method that permits the separation and prediction of the fully coherent airborne and structureborne components of the sound radiated by plates or thin shells has been developed. Analytical and experimental studies of the proposed method were performed on an aluminum plate. The results of the study indicate that the proposed method could be used in flight, and has fewer encumbrances than the other diagnostic tools currently available.

  8. Impact of the diagnostic changes to post-traumatic stress disorder for DSM-5 and the proposed changes to ICD-11.

    PubMed

    O'Donnell, Meaghan L; Alkemade, Nathan; Nickerson, Angela; Creamer, Mark; McFarlane, Alexander C; Silove, Derrick; Bryant, Richard A; Forbes, David

    2014-09-01

    There have been changes to the criteria for diagnosing post-traumatic stress disorder (PTSD) in DSM-5 and changes are proposed for ICD-11. To investigate the impact of the changes to diagnostic criteria for PTSD in DSM-5 and the proposed changes in ICD-11 using a large multisite trauma-exposed sample and structured clinical interviews. Randomly selected injury patients admitted to four hospitals were assessed 72 months post trauma (n = 510). Structured clinical interviews for PTSD and major depressive episode, as well as self-report measures of disability and quality of life were administered. Current prevalence of PTSD under DSM-5 scoring was not significantly different from DSM-IV (6.7% v. 5.9%, z = 0.53, P = 0.59). However, the ICD-11 prevalence was significantly lower than ICD-10 (3.3% v. 9.0%, z = -3.8, P<0.001). The PTSD current prevalence was significantly higher for DSM-5 than ICD-11 (6.7% v. 3.3%, z = 2.5, P = 0.01). Using ICD-11 tended to show lower rates of comorbidity with depression and a slightly lower association with disability. The diagnostic systems performed in different ways in terms of current prevalence rates and levels of comorbidity with depression, but on other broad key indicators they were relatively similar. There was overlap between those with PTSD diagnosed by ICD-11 and DSM-5 but a substantial portion met one but not the other set of criteria. This represents a challenge for research because the phenotype that is studied may be markedly different according to the diagnostic system used. Royal College of Psychiatrists.

  9. [CGM-continuous glucose monitoring - statement of the Austrian Diabetes Association].

    PubMed

    Schütz-Fuhrmann, Ingrid; Schober, Edith; Rami, Birgit; Stadler, Marietta; Bischof, Martin; Fortunat, Sandra; Laimer, Markus; Weitgasser, Raimund; Prager, Rudolf

    2012-12-01

    This position statement represents the recommendations of the Austrian Diabetes Association regarding the clinical diagnostic and therapeutic application, safety and benefits of continuous subcutaneous glucose monitoring systems in patients with diabetes mellitus, based on current evidence.

  10. [CGM-Continuous Glucose Monitoring--Statement of the Austrian Diabetes Association].

    PubMed

    Schütz-Fuhrmann, Ingrid; Rami-Merhar, Birgit; Hofer, Sabine; Stadler, Marietta; Bischof, Martin; Zlamal-Fortunat, Sandra; Laimer, Markus; Weitgasser, Raimund; Prager, Rudolf

    2016-04-01

    This position statement represents the recommendations of the Austrian Diabetes Association regarding the clinical diagnostic and therapeutic application, safety and benefits of continuous subcutaneous glucose monitoring systems in patients with diabetes mellitus, based on current evidence.

  11. The current status and future potential of personalized diagnostics: Streamlining a customized process.

    PubMed

    Richmond, Terri D

    2008-01-01

    Recent genetic discoveries and related developments in genomic techniques have led to the commercialization of novel diagnostic platforms for studying disease or gauging therapeutic outcomes in individual patients. This newly emerging field is called "personalized medicine," and uses the patient's genetic composition to tailor strategies for patient-specific disease detection, treatment, or prevention. Personalized diagnostic tests are used to detect patient-to-patient variations in gene or protein expression levels, which act as indicators for drug treatments or disease prognosis. In turn, medical professionals can better answer questions such as: "Who should be treated with which drug?" and "How should the treatment be administered?" The regulations governing personalized medicine can be complicated because they encompass in vitro diagnostic systems and laboratory tests as well as methods of disease treatment and patient care. Industry, academia, medicine, and the Food and Drug Administration (FDA) are all involved in the cultivation of the field: substantial collaborations between drug developers and regulatory authorities are required to consider and shape emerging regulations as personalized drug strategies mature. Some of the regulatory issues identified by industry and the FDA about personalized medicine and personalized diagnostics will be addressed. In addition, relevant collaborations, advances, and current and draft regulatory guidances will be discussed with respect to the future of personalized medicine.

  12. The Bipolar Affective Disorder Dimension Scale (BADDS) – a dimensional scale for rating lifetime psychopathology in Bipolar spectrum disorders

    PubMed Central

    Craddock, Nick; Jones, Ian; Kirov, George; Jones, Lisa

    2004-01-01

    Background Current operational diagnostic systems have substantial limitations for lifetime diagnostic classification of bipolar spectrum disorders. Issues include: (1) It is difficult to operationalize the integration of diverse episodes of psychopathology, (2) Hierarchies lead to loss of information, (3) Boundaries between diagnostic categories are often arbitrary, (4) Boundaries between categories usually require a major element of subjective interpretation, (5) Available diagnostic categories are relatively unhelpful in distinguishing severity, (6) "Not Otherwise Specified (NOS)" categories are highly heterogeneous, (7) Subclinical cases are not accommodated usefully within the current diagnostic categories. This latter limitation is particularly pertinent in the context of the increasing evidence for the existence of a broader bipolar spectrum than has been acknowledged within existing classifications. Method We have developed a numerical rating system, the Bipolar Affective Disorder Dimension Scale, BADDS, that can be used as an adjunct to conventional best-estimate lifetime diagnostic procedures. The scale definitions were informed by (a) the current concepts of mood syndrome recognized within DSMIV and ICD10, (b) the literature regarding severity of episodes, and (c) our own clinical experience. We undertook an iterative process in which we initially agreed scale definitions, piloted their use on sets of cases and made modifications to improve utility and reliability. Results BADDS has four dimensions, each rated as an integer on a 0 – 100 scale, that measure four key domains of lifetime psychopathology: Mania (M), Depression (D), Psychosis (P) and Incongruence (I). In our experience it is easy to learn, straightforward to use, has excellent inter-rater reliability and retains the key information required to make diagnoses according to DSMIV and ICD10. Conclusions Use of BADDS as an adjunct to conventional categorical diagnosis provides a richer description of lifetime psychopathology that (a) can accommodate sub-clinical features, (b) discriminate between illness severity amongst individuals within a single conventional diagnostic category, and (c) demonstrate the similarity between the illness experience of individuals who have been classified into different disease categories but whose illnesses both fall near the boundaries between the two categories. BADDS may be useful for researchers and clinicians who are interested in description and classification of lifetime psychopathology of individuals with disorders lying on the bipolar spectrum. PMID:15236660

  13. Engineering aspects of design and integration of ECE diagnostic in ITER

    DOE PAGES

    Udintsev, V. S.; Taylor, G.; Pandya, H. K.B.; ...

    2015-03-12

    ITER ECE diagnostic [1] needs not only to meet measurement requirements, but also to withstand various loads, such as electromagnetic, mechanical, neutronic and thermal, and to be protected from stray ECH radiation at 170 GHz and other millimeter wave emission, like Collective Thomson scattering which is planned to operate at 60 GHz. Same or similar loads will be applied to other millimetre-wave diagnostics [2], located both in-vessel and in-port plugs. These loads must be taken into account throughout the design phases of the ECE and other microwave diagnostics to ensure their structural integrity and maintainability. The integration of microwave diagnosticsmore » with other ITER systems is another challenging activity which is currently ongoing through port integration and in-vessel integration work. Port Integration has to address the maintenance and the safety aspects of diagnostics, too. Engineering solutions which are being developed to support and to operate ITER ECE diagnostic, whilst complying with safety and maintenance requirements, are discussed in this paper.« less

  14. Biologics industry challenges for developing diagnostic tests for the National Veterinary Stockpile.

    PubMed

    Hardham, J M; Lamichhane, C M

    2013-01-01

    Veterinary diagnostic products generated ~$3 billion US dollars in global sales in 2010. This industry is poised to undergo tremendous changes in the next decade as technological advances move diagnostic products from the traditional laboratory-based and handheld immunologic assays towards highly technical, point of care devices with increased sensitivity, specificity, and complexity. Despite these opportunities for advancing diagnostic products, the industry continues to face numerous challenges in developing diagnostic products for emerging and foreign animal diseases. Because of the need to deliver a return on the investment, research and development dollars continue to be focused on infectious diseases that have a negative impact on current domestic herd health, production systems, or companion animal health. Overcoming the administrative, legal, fiscal, and technological barriers to provide veterinary diagnostic products for the National Veterinary Stockpile will reduce the threat of natural or intentional spread of foreign diseases and increase the security of the food supply in the US.

  15. Molecular Diagnostics in Transfusion Medicine: In Capillary, on a Chip, in Silico, or in Flight?

    PubMed Central

    Garritsen, Henk S.P.; Xiu-Cheng Fan, Alex; Lenz, Daniela; Hannig, Horst; Yan Zhong, Xiao; Geffers, Robert; Lindenmaier, Werner; Dittmar, Kurt E.J.; Wörmann, Bernhard

    2009-01-01

    Summary Serology, defined as antibody-based diagnostics, has been regarded as the diagnostic gold standard in transfusion medicine. Nowadays however the impact of molecular diagnostics in transfusion medicine is rapidly growing. Molecular diagnostics can improve tissue typing (HLA typing), increase safety of blood products (NAT testing of infectious diseases), and enable blood group typing in difficult situations (after transfusion of blood products or prenatal non-invasive RhD typing). Most of the molecular testing involves the determination of the presence of single nucleotide polymorphisms (SNPs). Antigens (e.g. blood group antigens) mostly result from single nucleotide differences in critical positions. However, most blood group systems cannot be determined by looking at a single SNP. To identify members of a blood group system a number of critical SNPs have to be taken into account. The platforms which are currently used to perform molecular diagnostics are mostly gel-based, requiring time-consuming multiple manual steps. To implement molecular methods in transfusion medicine in the future the development of higher-throughput SNP genotyping non-gel-based platforms which allow a rapid, cost-effective screening are essential. Because of its potential for automation, high throughput and cost effectiveness the special focus of this paper is a relative new technique: SNP genotyping by MALDI-TOF MS analysis. PMID:21113259

  16. Might telesonography be a new useful diagnostic tool aboard merchant ships? A pilot study.

    PubMed

    Nikolić, Nebojsa; Mozetić, Vladimir; Modrcin, Bob; Jaksić, Slaven

    2006-01-01

    Developments of new, ultra-light diagnostic ultrasound systems (UTS) and modern satellite telecommunication networks are opening new potential applications for diagnostic sonography. One such area is maritime medicine. It is our belief that ship officers can be trained to use diagnostic ultrasound systems with the aim to generate ultrasound images of sufficient quality to be interpreted by medical professionals qualified to read sonograms. To test our thesis we included lectures and hands on scanning practice to the current maritime medicine curriculum at the Faculty of Maritime Studies at the University of Rijeka. Following the didactic and practical training all participating students examined several patients, some with pathology some without. Images obtained by students were then submitted for interpretation to a qualified physician (specialist of general surgery trained in UTS) who was unaware of the patient's pathology. In total, 37 students performed 37 examinations and made 45 ultrasound images, on 3 patients. In this paper, results on this pilot study are presented. It is possible to teach ship officers to produce diagnostically usable ultrasound pictures aboard ships at sea. But before reaching final conclusion about applicability of telesonography on board merchant ships, further studies are necessary, that would include studies of economic feasibility, and on validity of introducing such a diagnostic tool to the maritime medical practice.

  17. Update on the DIII-D ECH system: experiments, gyrotrons, advanced diagnostics, and controls

    NASA Astrophysics Data System (ADS)

    Lohr, John; Brambila, Rigoberto; Cengher, Mirela; Gorelov, Yuri; Grosnickle, William; Moeller, Charles; Ponce, Dan; Torrezan, Antonio; Ives, Lawrence; Reed, Michael; Blank, Monica; Felch, Kevin; Parisuaña, Claudia; LeViness, Alexandra

    2017-08-01

    The ECH system on DIII-D is continuing to be upgraded, while simultaneously being operated nearly daily for plasma experiments. The latest major hardware addition is a new 117.5 GHz gyrotron, which generated 1.7 MW for short pulses during factory testing. A new gyrotron control system based on Field Programmable Gate Array (FPGA) technology with very high speed system data acquisition has significantly increased the flexibility and reliability of individual gyrotron operation. We have improved the performance of the fast mirror scanning, both by increasing the scan speeds and by adding new algorithms for controlling the aiming using commands generated by the Plasma Control System (PCS). The system is used for transport studies, ELM control, current profile control, non-inductive current generation, suppression of MHD modes, startup assist, plasma density control, and other applications. A program of protective measures, which has been in place for more than two years, has eliminated damage to hardware and diagnostics caused by overdense operation. Other activities not directly related to fusion research have used the ECH system to test components, study methods for improving production of semiconductor junctions and materials, and test the feasibility of using ground based microwave systems to power satellites into orbit.

  18. Quantifying Novice and Expert Differences in Visual Diagnostic Reasoning in Veterinary Pathology Using Eye-Tracking Technology.

    PubMed

    Warren, Amy L; Donnon, Tyrone L; Wagg, Catherine R; Priest, Heather; Fernandez, Nicole J

    2018-01-18

    Visual diagnostic reasoning is the cognitive process by which pathologists reach a diagnosis based on visual stimuli (cytologic, histopathologic, or gross imagery). Currently, there is little to no literature examining visual reasoning in veterinary pathology. The objective of the study was to use eye tracking to establish baseline quantitative and qualitative differences between the visual reasoning processes of novice and expert veterinary pathologists viewing cytology specimens. Novice and expert participants were each shown 10 cytology images and asked to formulate a diagnosis while wearing eye-tracking equipment (10 slides) and while concurrently verbalizing their thought processes using the think-aloud protocol (5 slides). Compared to novices, experts demonstrated significantly higher diagnostic accuracy (p<.017), shorter time to diagnosis (p<.017), and a higher percentage of time spent viewing areas of diagnostic interest (p<.017). Experts elicited more key diagnostic features in the think-aloud protocol and had more efficient patterns of eye movement. These findings suggest that experts' fast time to diagnosis, efficient eye-movement patterns, and preference for viewing areas of interest supports system 1 (pattern-recognition) reasoning and script-inductive knowledge structures with system 2 (analytic) reasoning to verify their diagnosis.

  19. Rolling Out Xpert® MTB/RIF for TB Detection in HIV-Infected Populations:An Opportunity for Systems Strengthening.

    PubMed

    Pathmanathan, Ishani; Date, Anand; Coggin, William L; Nkengasong, John; Piatek, Amy S; Alexander, Heather

    2017-03-31

    To eliminate preventable deaths, disease and suffering due to tuberculosis (TB), improved diagnostic capacity is critical. The Cepheid Xpert ® MTB/RIF assay is recommended by the World Health Organization as the initial diagnostic test for people with suspected HIV-associated TB. However, despite high expectations, its scale-up in real-world settings has faced challenges, often due to the systems that support it. In this commentary we discuss needs and opportunities for systems strengthening to support widespread scale-up of Xpert ® MTB/RIF as they relate to each step within the TB diagnostic cascade, from finding presumptive patients, to collecting, transporting and testing sputum specimens, to reporting and receiving results, to initiating and monitoring treatment and, ultimately, to ensuring successful and timely treatment and cure. Investments in evidence-based interventions at each step along the cascade and within the system as a whole will augment not only the utility of Xpert ® MTB/RIF, but also the successful implementation of future diagnostic tests. Xpert ® MTB/RIF will only improve patient outcomes if optimally implemented within the context of strong TB programs and systems. Roll-out of this technology to people living with HIV and others in resource-limited settings offers the opportunity to leverage current TB and HIV laboratory, diagnostic and programmatic investments, while also addressing challenges and strengthening coordination between laboratory systems, laboratory-program interfaces, and TB-HIV program interfaces. If successful, the benefits of this tool could extend beyond progress towards global End TB Strategy goals, to improve system-wide capacity for global disease detection and control.

  20. GIS diagnostics: thermal imaging systems used for poor contact detection

    NASA Astrophysics Data System (ADS)

    Avital, Doron; Brandenbursky, V.; Farber, A.

    2004-04-01

    The reliability of GIS is very high but any failure that occurs can cause extensive damage result and the repair times are considerably long. The consequential losses to system security and economically can be high, especially if the nominal GIS voltage is 420 kV and above. In view of these circumstances, increasing attention is being given to diagnostic techniques for in-service maintenance undertaken to improve the reliability and availability of GIS. Recently considerable progress has been made in diagnostic techniques and they are now used successfully during the service life of the equipment. These diagnostic techniques in general focus on the GIS insulation system and are based on partial discharge (PD) measurements in GIS. There are three main methods for in-service PD detection in GIS: - the chemical method that rely on the detection of cracked gas caused by PD, the acoustic method designed to detect the acoustic emission excited by PD, and, the electrical method which is based on detection of electrical resonance at ultra high frequencies (UHF) up to 1.5 GHz caused by PD excitation in GIS chambers (UHF method). These three dielectric diagnostic methods cannot be used for the detection of poor current carrying contacts in GIS. This problem does not always produce partial discharges and at early stages it does not cause gas cracking. An interesting solution to use two techniques - the current unbalance alarm scheme and partial discharge monitoring was advised by A. Salinas from South California Edison Co. Unfortunately this way is complicated and very expensive. The investigations performed in Japan on standing alone SF6 breaker showed that joule heating of the contact accompanied by released power of 1600 Watt produce temperature difference on the enclosure up to 7 degrees centigrade that could be detected by infra-red Thermal Imaging System. According to CIGRE Joint Working Group 33/23.12 Report, 11% of all GIS failures are due to poor current carrying contacts in GIS. The Israel Electric Company (IEC) in seeking a solution to this problem have undertaken experimental work to examine the possibility of in-service diagnostic of poor contact problem in GIS via direct local heating detection, using a Thermal Imaging System. The experiments were carried out on the part of the GIS with nominal SF6 pressure. The following aspects of the problem were examined: - the range of power released in the defective contact that could give the practical temperature rise on the surface of enclosure; - temperature distribution on the surface of enclosure; - the influence of spacer type (with holes or without) on the heat transfer process; - the influence of the length of SF6 tubes and there position (horizontal or vertical); - the temperature difference between upper and lower parts of the tubes in horizontal position; - practical use of the Thermal Imaging System for detecting poor contact problem in GIS.

  1. Status report on Project Hercules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loree, D.; Giesselmann, M.; Kristiansen, M.

    1993-01-01

    Project Hercules is a project to improve ignitron switches which will then be used on the upgrade of Lawrence Livermore's Nova Laser for their ICF program. The goals of Hercules, which stands for High Energy Research Concerning the Ultimate Lifetime of Experimental Switches, are to lifetime test (up to 10,000 shots) prototype ignitrons or other switches with the required Nova current and coulomb parameters (300 kA, 200 C), recommend design changes, and retest the second generation switches. This report describes the design and construction of the test circuit and necessary diagnostics. The details of the design and construction of themore » test circuit and necessary diagnostics. The details of the design and construction of a 0.5 MJ electrolytic capacitor bank and a semi-automatic diagnostic/control system are described. The required test run data include peak current and corresponding tube voltage for every shot, entire current and voltage waveforms every few shots, and ignitor resistance values every few shots. Additionally, the conversion of a 120 kW, 12 kV constant voltage supply to an 8 A constant current supply with the use of six SCRs and a commercial control board will be described. The final results of this project will be lifetime data at high current and high coulomb for and improvements on some of the best of the new generation of pulsed power switches.« less

  2. Company Level Logistics on the Future Battlefield.

    DTIC Science & Technology

    1993-12-17

    also expands the terrain envelope in which responsive logistics can be provided. Self diagnostic equipment is currently imbedded in many of our new ...satellite systems, improved sensors, better communications, and long range weapons systems. The combined effect of these systems creates a new ...battlefield. To support combat operations in light of these changes, logistics units must adapt to the new environment. In the past American logistics units

  3. Virtualization of AEGIS: A Study of the Feasibility of Applying Open Architecture Technology to the Surface Navy’s Most Complex Automated Weapon System

    DTIC Science & Technology

    2011-09-01

    diagnostics system. Aerospace and Electronic Systems Magazine, IEEE , 9(2), 40–45. Current version released August 2002 in IEEE Xplore . doi: 10.1109...Cramming more components onto integrated circuits. Electronics, 114–117. Reprinted January 1998 in Proceedings of the IEEE , 86(1), 82–85. doi: S 0018

  4. A modular neural network scheme applied to fault diagnosis in electric power systems.

    PubMed

    Flores, Agustín; Quiles, Eduardo; García, Emilio; Morant, Francisco; Correcher, Antonio

    2014-01-01

    This work proposes a new method for fault diagnosis in electric power systems based on neural modules. With this method the diagnosis is performed by assigning a neural module for each type of component comprising the electric power system, whether it is a transmission line, bus or transformer. The neural modules for buses and transformers comprise two diagnostic levels which take into consideration the logic states of switches and relays, both internal and back-up, with the exception of the neural module for transmission lines which also has a third diagnostic level which takes into account the oscillograms of fault voltages and currents as well as the frequency spectrums of these oscillograms, in order to verify if the transmission line had in fact been subjected to a fault. One important advantage of the diagnostic system proposed is that its implementation does not require the use of a network configurator for the system; it does not depend on the size of the power network nor does it require retraining of the neural modules if the power network increases in size, making its application possible to only one component, a specific area, or the whole context of the power system.

  5. A Modular Neural Network Scheme Applied to Fault Diagnosis in Electric Power Systems

    PubMed Central

    Flores, Agustín; Morant, Francisco

    2014-01-01

    This work proposes a new method for fault diagnosis in electric power systems based on neural modules. With this method the diagnosis is performed by assigning a neural module for each type of component comprising the electric power system, whether it is a transmission line, bus or transformer. The neural modules for buses and transformers comprise two diagnostic levels which take into consideration the logic states of switches and relays, both internal and back-up, with the exception of the neural module for transmission lines which also has a third diagnostic level which takes into account the oscillograms of fault voltages and currents as well as the frequency spectrums of these oscillograms, in order to verify if the transmission line had in fact been subjected to a fault. One important advantage of the diagnostic system proposed is that its implementation does not require the use of a network configurator for the system; it does not depend on the size of the power network nor does it require retraining of the neural modules if the power network increases in size, making its application possible to only one component, a specific area, or the whole context of the power system. PMID:25610897

  6. Teaching DSM-III to clinicians. Some problems of the DSM-III system reducing reliability, using the diagnosis and classification of depressive disorders as an example.

    PubMed

    Malt, U F

    1986-01-01

    Experiences from teaching DSM-III to more than three hundred Norwegian psychiatrists and clinical psychologists suggest that reliable DSM-III diagnoses can be achieved within a few hours training with reference to the decision trees and the diagnostic criteria only. The diagnoses provided are more reliable than the corresponding ICD diagnoses which the participants were more familiar with. The three main sources of reduced reliability of the DSM-III diagnoses are related to: poor knowledge of the criteria which often is connected with failure of obtaining diagnostic key information during the clinical interview; unfamiliar concepts and vague or ambiguous criteria. The two first issues are related to the quality of the teaching of DSM-III. The third source of reduced reliability reflects unsolved validity issues. By using the classification of five affective case stories as examples, these sources of diagnostic pitfalls, reducing reliability and ways to overcome these problems when teaching the DSM-III system, are discussed. It is concluded that the DSM-III system of classification is easy to teach and that the system is superior to other classification systems available from a reliability point of view. The current version of the DSM-III system, however, partly owes a high degree of reliability to broad and heterogeneous diagnostic categories like the concept major depression, which may have questionable validity. Thus, the future revisions of the DSM-III system should, above all, address the issue of validity.

  7. Current status for gastrointestinal nematode diagnosis in small ruminants: where are we and where are we going?

    PubMed

    Preston, Sarah Jane Margaret; Sandeman, Mark; Gonzalez, Jorge; Piedrafita, David

    2014-01-01

    Gastrointestinal nematode (GIN) parasites pose a significant economic burden particularly in small ruminant production systems. Anthelmintic resistance is a serious concern to the effective control of GIN parasites and has fuelled the focus to design and promote sustainable control of practices of parasite control. Many facets of sustainable GIN parasite control programs rely on the ability to diagnose infection both qualitatively and quantitatively. Diagnostics are required to determine anthelmintic efficacies, for targeted treatment programs and selection of animals for parasite resistant breeding. This review describes much of the research investigated to date to improve the current diagnostic for the above practices which is based on counting the number of parasite eggs in faeces.

  8. Linking medical records to an expert system

    NASA Technical Reports Server (NTRS)

    Naeymi-Rad, Frank; Trace, David; Desouzaalmeida, Fabio

    1991-01-01

    This presentation will be done using the IMR-Entry (Intelligent Medical Record Entry) system. IMR-Entry is a software program developed as a front-end to our diagnostic consultant software MEDAS (Medical Emergency Decision Assistance System). MEDAS (the Medical Emergency Diagnostic Assistance System) is a diagnostic consultant system using a multimembership Bayesian design for its inference engine and relational database technology for its knowledge base maintenance. Research on MEDAS began at the University of Southern California and the Institute of Critical Care in the mid 1970's with support from NASA and NSF. The MEDAS project moved to Chicago in 1982; its current progress is due to collaboration between Illinois Institute of Technology, The Chicago Medical School, Lake Forest College and NASA at KSC. Since the purpose of an expert system is to derive a hypothesis, its communication vocabulary is limited to features used by its knowledge base. The development of a comprehensive problem based medical record entry system which could handshake with an expert system while creating an electronic medical record at the same time was studied. IMR-E is a computer based patient record that serves as a front end to the expert system MEDAS. IMR-E is a graphically oriented comprehensive medical record. The programs major components are demonstrated.

  9. Strategic bombers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-07-01

    This paper reports on the questions: should Congress provide more funds for the Air Force's current plan---the CORE program---to upgrade the B-1B defense avionics system In GAO's view, more testing of the system is not necessary to determine whether to implement the CORE program. Flight testing has shown that the CORE modifications would provide similar operational capabilities to, and offer some survivability improvements over, the existing defense avionics system. The only reason for additional testing would be to prove that some problems with the maintenance diagnostic system has been resolved. Initial testing revealed that while some improvements were achieved, usermore » requirements were not met for such things as low false alarm rates and cannot duplicate rates. Even if the maintenance diagnostic capabilities were fully demonstrated, however, the CORE system should not be implemented until it is known whether the defense avionics system design can support the B-1B's new role as a conventional bomber.« less

  10. A review of intelligent systems for heart sound signal analysis.

    PubMed

    Nabih-Ali, Mohammed; El-Dahshan, El-Sayed A; Yahia, Ashraf S

    2017-10-01

    Intelligent computer-aided diagnosis (CAD) systems can enhance the diagnostic capabilities of physicians and reduce the time required for accurate diagnosis. CAD systems could provide physicians with a suggestion about the diagnostic of heart diseases. The objective of this paper is to review the recent published preprocessing, feature extraction and classification techniques and their state of the art of phonocardiogram (PCG) signal analysis. Published literature reviewed in this paper shows the potential of machine learning techniques as a design tool in PCG CAD systems and reveals that the CAD systems for PCG signal analysis are still an open problem. Related studies are compared to their datasets, feature extraction techniques and the classifiers they used. Current achievements and limitations in developing CAD systems for PCG signal analysis using machine learning techniques are presented and discussed. In the light of this review, a number of future research directions for PCG signal analysis are provided.

  11. Pregnancy and mesenchimal dysplasias (Marfan syndrome, Ehlers-Danlos syndrome, hereditary hemorrhagic telangiectasia).

    PubMed

    Radetskaya, L S; Makatsariya, A D; Bitsadze, V O; Khizroeva, J K

    2018-07-01

    The objective of this article is to attract the attention of clinical physicians to the rare but extremely relevant clinical pathology of mesenchymal dysplasias (Marfan syndrome, Ehlers-Danlos syndrome, hereditary hemorrhagic telangiectasia) and especially specific characteristics of such diseases during pregnancy. Connective tissue pathology can cover different organs and systems, symptoms of the same disease can vary in different patients thus making diagnostics significantly difficult. Here clinical diagnostic criteria and methods of molecular diagnostics of diseases are described. The pathogenesis of mesenchymal dysplasias is not currently well understood. For the patients with mesenchymal dysplasias pregnancy is fraught with high risk of life-threatening complications. The preferred delivery method for such patients is caesarean section.

  12. [Pedophilia: etiology, diagnostics and therapy].

    PubMed

    Fromberger, P; Jordan, K; Müller, J L

    2013-09-01

    Child sexual abuse is one of the most destructive events for healthy child development. Following psychiatric classification systems, pedophilia must be distinguished from child sexual abuse. Approximately only one half of all child abusers fulfill the diagnostic criteria for pedophilia which is defined as a persistent or dominating sexual preference for prepubescent children characterized by persistent thoughts, fantasies, urges, sexual arousal or behavior. This article describes the diagnostic criteria and potential differential diagnoses as well as epidemiological and etiological findings. From an etiological point of view multifactorial mechanisms are currently considered to be responsible especially genetic factors, learning theoretical and neurobiological factors. Psychotherapeutic and pharmaceutical treatment options will be discussed. According to the current state of knowledge cognitive-behavioral psychotherapy is the method of choice in the treatment of pedophilia and has demonstrated positive treatment effects in meta-analyses regarding relapse prevention. Medicinal treatment of pedophilia is only indicated for severe forms of pedophilia. Important aspects of risk management in the treatment of pedophilia and aspects which must be considered in the forensic psychiatric assessment are presented.

  13. Rapid tests for diagnosis of leptospirosis: current tools and emerging technologies.

    PubMed

    Picardeau, Mathieu; Bertherat, Eric; Jancloes, Michel; Skouloudis, Andreas N; Durski, Kara; Hartskeerl, Rudy A

    2014-01-01

    Leptospirosis is an emerging zoonosis with a worldwide distribution but is more commonly found in impoverished populations in developing countries and tropical regions with frequent flooding. The rapid detection of leptospirosis is a critical step to effectively manage the disease and to control outbreaks in both human and animal populations. Therefore, there is a need for accurate and rapid diagnostic tests and appropriate surveillance and alert systems to identify outbreaks. This review describes current in-house methods and commercialized tests for the rapid diagnosis of acute leptospirosis. It focuses on diagnostic tests that can be performed with minimal training and limited equipment in less-developed and newly industrialized countries, particularly in resource-limited settings and with results in minutes to less than 4 hours. We also describe recent technological advances in the field of diagnostic tests that could allow for the development of innovative rapid tests in the near future. © 2013 Elsevier Inc. All rights reserved.

  14. Application of Motion Induced Remote-Field Eddy-Current effect to online inspection and quality examination of rolling metallic strips

    NASA Astrophysics Data System (ADS)

    Sun, Yushi; Udpa, Satish; Lord, William; Udpa, Lalita; Ouyang, Tianhe

    2001-04-01

    The Motion Induced Remote-Field Eddy-Current (MIRFEC) effect was first observed in 1994. The effect was first exploited for detecting pipeline stress corrosion cracks as a part of a research project sponsored by the U.S. Department of Transportation. This paper presents a new application of the MIRFEC effect for online inspection of rolling metallic strips. Currently, rolled metallic strips and sheets are inspected off-line, which is costly, time consuming and not ideal for quality control. A well-designed online diagnostic and control system for metal rolling process may be able to reduce cost, improve quality, and hence enhance competitiveness of the product. The overall objective of this paper is to demonstrate the feasibility of a new nondestructive measurement system for on-line diagnostics and control of metallic rolling process using the MIRFEC effect. The system can be used to monitor, in real time, metallic strips/sheets for possible anomalies, inclusions, voids, bubbles, lamination, as well as variations in its magnetic and other properties. The potential advantages of the MIRFEC system include simplicity, robustness, low cost, high reliability, quick and accurate signal classification and characterization. Such systems can be used for real-time process control, or off-line data analysis. The technique also allows operation at high temperatures, tolerates large lift-off and vibration, and high rolling speed. Results of finite element modeling of the MIRFEC effect and experimental measurement data obtained from a prototype system are presented.

  15. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  16. Genetic tests in major psychiatric disorders-integrating molecular medicine with clinical psychiatry-why is it so difficult?

    PubMed

    Demkow, U; Wolańczyk, T

    2017-06-13

    With the advent of post-genomic era, new technologies create extraordinary possibilities for diagnostics and personalized therapy, transforming todays' medicine. Rooted in both medical genetics and clinical psychiatry, the paper is designed as an integrated source of information of the current and potential future application of emerging genomic technologies as diagnostic tools in psychiatry, moving beyond the classical concept of patient approach. Selected approaches are presented, starting from currently used technologies (next-generation sequencing (NGS) and microarrays), followed by newer options (reverse phenotyping). Next, we describe an old concept in a new light (endophenotypes), subsequently coming up with a sophisticated and complex approach (gene networks) ending by a nascent field (computational psychiatry). The challenges and barriers that exist to translate genomic research to real-world patient assessment are further discussed. We emphasize the view that only a paradigm shift can bring a fundamental change in psychiatric practice, allowing to disentangle the intricacies of mental diseases. All the diagnostic methods, as described, are directed at uncovering the integrity of the system including many types of relations within a complex structure. The integrative system approach offers new opportunity to connect genetic background with specific diseases entities, or concurrently, with symptoms regardless of a diagnosis. To advance the field, we propose concerted cross-disciplinary effort to provide a diagnostic platform operating at the general level of genetic pathogenesis of complex-trait psychiatric disorders rather than at the individual level of a specific disease.

  17. Genetic tests in major psychiatric disorders—integrating molecular medicine with clinical psychiatry—why is it so difficult?

    PubMed Central

    Demkow, U; Wolańczyk, T

    2017-01-01

    With the advent of post-genomic era, new technologies create extraordinary possibilities for diagnostics and personalized therapy, transforming todays’ medicine. Rooted in both medical genetics and clinical psychiatry, the paper is designed as an integrated source of information of the current and potential future application of emerging genomic technologies as diagnostic tools in psychiatry, moving beyond the classical concept of patient approach. Selected approaches are presented, starting from currently used technologies (next-generation sequencing (NGS) and microarrays), followed by newer options (reverse phenotyping). Next, we describe an old concept in a new light (endophenotypes), subsequently coming up with a sophisticated and complex approach (gene networks) ending by a nascent field (computational psychiatry). The challenges and barriers that exist to translate genomic research to real-world patient assessment are further discussed. We emphasize the view that only a paradigm shift can bring a fundamental change in psychiatric practice, allowing to disentangle the intricacies of mental diseases. All the diagnostic methods, as described, are directed at uncovering the integrity of the system including many types of relations within a complex structure. The integrative system approach offers new opportunity to connect genetic background with specific diseases entities, or concurrently, with symptoms regardless of a diagnosis. To advance the field, we propose concerted cross-disciplinary effort to provide a diagnostic platform operating at the general level of genetic pathogenesis of complex-trait psychiatric disorders rather than at the individual level of a specific disease. PMID:28608853

  18. A neutron diagnostic for high current deuterium beams.

    PubMed

    Rebai, M; Cavenago, M; Croci, G; Dalla Palma, M; Gervasini, G; Ghezzi, F; Grosso, G; Murtas, F; Pasqualotto, R; Cippo, E Perelli; Tardocchi, M; Tollin, M; Gorini, G

    2012-02-01

    A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45°. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

  19. A neutron diagnostic for high current deuterium beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rebai, M.; Perelli Cippo, E.; Cavenago, M.

    2012-02-15

    A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thinmore » polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.« less

  20. Conventional and molecular diagnostic strategies for prosthetic joint infections.

    PubMed

    Esteban, Jaime; Sorlí, Luisa; Alentorn-Geli, Eduard; Puig, Lluís; Horcajada, Juan P

    2014-01-01

    An accurate diagnosis of prosthetic joint infection (PJI) is the mainstay for an optimized clinical management. This review analyzes different diagnostic strategies of PJI, with special emphasis on molecular diagnostic tools and their current and future applications. Until now, the culture of periprosthetic tissues has been considered the gold standard for the diagnosis of PJI. However, sonication of the implant increases the sensitivity of those cultures and is being increasingly adopted by many centers. Molecular diagnostic methods compared with intraoperative tissue culture, especially if combined with sonication, have a higher sensitivity, a faster turnaround time and are not influenced by previous antimicrobial therapy. However, they still lack a system for detection of antimicrobial susceptibility, which is crucial for an optimized and less toxic therapy of PJI. More studies are needed to assess the clinical value of these methods and their cost-effectiveness.

  1. 21 CFR 868.6225 - Nose clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  2. An Overview of Prognosis Health Management Research at Glenn Research Center for Gas Turbine Engine Structures With Special Emphasis on Deformation and Damage Modeling

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M.; Goldberg, Robert K.; Lerch, Bradley A.; Saleeb, Atef F.

    2009-01-01

    Herein a general, multimechanism, physics-based viscoelastoplastic model is presented in the context of an integrated diagnosis and prognosis methodology which is proposed for structural health monitoring, with particular applicability to gas turbine engine structures. In this methodology, diagnostics and prognostics will be linked through state awareness variable(s). Key technologies which comprise the proposed integrated approach include (1) diagnostic/detection methodology, (2) prognosis/lifing methodology, (3) diagnostic/prognosis linkage, (4) experimental validation, and (5) material data information management system. A specific prognosis lifing methodology, experimental characterization and validation and data information management are the focal point of current activities being pursued within this integrated approach. The prognostic lifing methodology is based on an advanced multimechanism viscoelastoplastic model which accounts for both stiffness and/or strength reduction damage variables. Methods to characterize both the reversible and irreversible portions of the model are discussed. Once the multiscale model is validated the intent is to link it to appropriate diagnostic methods to provide a full-featured structural health monitoring system.

  3. An Overview of Prognosis Health Management Research at GRC for Gas Turbine Engine Structures With Special Emphasis on Deformation and Damage Modeling

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M.; Goldberg, Robert K.; Lerch, Bradley A.; Saleeb, Atef F.

    2009-01-01

    Herein a general, multimechanism, physics-based viscoelastoplastic model is presented in the context of an integrated diagnosis and prognosis methodology which is proposed for structural health monitoring, with particular applicability to gas turbine engine structures. In this methodology, diagnostics and prognostics will be linked through state awareness variable(s). Key technologies which comprise the proposed integrated approach include 1) diagnostic/detection methodology, 2) prognosis/lifing methodology, 3) diagnostic/prognosis linkage, 4) experimental validation and 5) material data information management system. A specific prognosis lifing methodology, experimental characterization and validation and data information management are the focal point of current activities being pursued within this integrated approach. The prognostic lifing methodology is based on an advanced multi-mechanism viscoelastoplastic model which accounts for both stiffness and/or strength reduction damage variables. Methods to characterize both the reversible and irreversible portions of the model are discussed. Once the multiscale model is validated the intent is to link it to appropriate diagnostic methods to provide a full-featured structural health monitoring system.

  4. Vanishing tattoo multi-sensor for biomedical diagnostics

    NASA Astrophysics Data System (ADS)

    Moczko, E.; Meglinski, I.; Piletsky, S.

    2008-04-01

    Currently, precise non-invasive diagnostics systems for the real-time multi detection and monitoring of physiological parameters and chemical analytes in the human body are urgently required by clinicians, physiologists and bio-medical researchers. We have developed a novel cost effective smart 'vanishing tattoo' (similar to temporary child's tattoos) consisting of environmental-sensitive dyes. Painlessly impregnated into the skin the smart tattoo is capable of generating optical/fluorescence changes (absorbance, transmission, reflectance, emission and/or luminescence within UV, VIS or NIR regions) in response to physical or chemical changes. These changes allow the identification of colour pattern changes similar to bar-code scanning. Such a system allows an easy, cheap and robust comprehensive detection of various parameters and analytes in a small volume of sample (e.g. variations in pH, temperature, ionic strength, solvent polarity, presence of redox species, surfactants, oxygen). These smart tattoos have possible applications in monitoring the progress of disease and transcutaneous drug delivery. The potential of this highly innovative diagnostic tool is wide and diverse and can impact on routine clinical diagnostics, general therapeutic management, skin care and cosmetic products testing as well as fundamental physiological investigations.

  5. Vanishing "tattoo" multisensor for biomedical diagnostics

    NASA Astrophysics Data System (ADS)

    Moczko, E.; Meglinski, I.; Piletsky, S.

    2008-02-01

    Currently, precise non-invasive diagnostics systems for the real-time multi detection and monitoring of physiological parameters and chemical analytes in the human body are urgently required by clinicians, physiologists and bio-medical researchers. We have developed a novel cost effective smart 'vanishing tattoo' (similar to temporary child's tattoos) consisting of environmental-sensitive dyes. Painlessly impregnated into the skin the smart tattoo is capable of generating optical/fluorescence changes (absorbance, transmission, reflectance, emission and/or luminescence within UV, VIS or NIR regions) in response to physical or chemical changes. These changes allow the identification of colour pattern changes similar to bar-code scanning. Such a system allows an easy, cheap and robust comprehensive detection of various parameters and analytes in a small volume of sample (e.g. variations in pH, temperature, ionic strength, solvent polarity, presence of redox species, surfactants, oxygen). These smart tattoos have possible applications in monitoring the progress of disease and transcutaneous drug delivery. The potential of this highly innovative diagnostic tool is wide and diverse and can impact on routine clinical diagnostics, general therapeutic management, skin care and cosmetic products testing as well as fundamental physiological investigations.

  6. Summary of EM launcher experiments performed at LLNL

    NASA Astrophysics Data System (ADS)

    Hawke, R. S.; Nellis, W. J.; Newman, G. H.; Rego, J.; Susoeff, A. R.

    1986-11-01

    Performance results for three railguns are summarized. The system used a helium gas-driven injector and railgun launcher to accelerate 1- and 4-g polycarbonate projectiles intact up to 6.6 and 3.0 km/sc, respectively. A 625 kJ capacitor bank powered the railgun, and an adjustable inductor provided pulse shaping and peak current control. Operation in hard and soft vacuum was reliably achieved. The diagnostic system measured the projectile position and launch velocity, verified that the projectile was launched intact in the desired direction, and identified system components where improvements could enhance performance. Flash X-ray radiography measured velocity and verified that projectiles were intact. Pre-launch projectile travel along the axis of the launcher without tilt was recorded with flash radiographs and impact impressions or holes in witness plates. The sysem performed as expected up to 4-5 km/sec but below expectations at higher velocities. Diagnostics suggest that the decreased performance was probably cuased by the restriking of a second arc in the breech of the railgun, which shunted the current from the propulsive arc.

  7. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  8. A proposal for antiparallel acceleration of positrons using CEBAF

    NASA Astrophysics Data System (ADS)

    Tiefenback, M.; Wojtsekhowski, B.

    2018-05-01

    We present a scheme for positron beam acceleration in CEBAF antiparallel to the normal electron path, requiring no change in polarity of the magnet systems. This feature is essential to the principal benefit: enabling extremely simple configuration changes between conventional (clockwise) e- acceleration and counter clockwise e+ acceleration. Additionally, it appears possible to configure the accelerating cavity phases to support concurrent acceleration of the electron and positron beams. The last mode also may enable use of the higher peak current electron beam for system diagnostics. The inherent penalty of the concurrent mode in acceleration efficiency and increased energy spread may render this a commissioning-only diagnostic option, but the possibility appears worthy of consideration.

  9. Electrical signal analysis to assess the physical condition of a human or animal

    DOEpatents

    Cox, Daryl F.; Hochanadel, Charles D.; Haynes, Howard D.

    2010-06-15

    The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

  10. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 2; Acquire TM Date for Type B Sensors for "Express-A" Number 2 Satellite for the Period of March 12, 2000 to and Including June 15, 2000, Task 25

    NASA Technical Reports Server (NTRS)

    Dunning, John (Technical Monitor); Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  11. Hall Effect Thruster Interactions Data from the Russian Express-A2 and Express-A3 Satellites. Part 4; Acquire TM-Data for Type A and Type B Sensors for "Express-A" Number 3 Satellite, Task 27A

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80deg E., and 11deg W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3-99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  12. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Acquire Express-A2 SPT-100 Based Propulsion Subsystem and Other Subsystem Flight Operation TM-Data for the Period of March 12, 2000 to and Including June 15, 2000, Task 29

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney s Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  13. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 11; Express/T-160E Project Express A2 and A3 Data Agreement Document

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.; Dunning, John (Technical Monitor)

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80deg E. and 11deg W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3-99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  14. Hall Effect Thruster Interactions Data from the Russian Express-A2 and Express-A3 Satellites. Part 5; Acquire Express-A3 SPT?100 Based Propulsion Subsystem and Other Subsystem Flight Operation TM-Data, Task 31

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80deg E. and 11deg W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3-99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  15. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 12; Express/T-160 Project Express A2 and A3 Sensors Operations Procedures Document

    NASA Technical Reports Server (NTRS)

    Dunning, John (Technical Monitor); Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 deg. E. and 11 deg. W respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  16. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Acquire Express-A3 SPT 100 Based Propulsion Subsystem and Other Subsystem Flight Operation TM-Data, Task 33

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 deg E and 11 deg W, respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3-99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  17. Development of a high current 60 keV neutral lithium beam injector for beam emission spectroscopy measurements on fusion experiments.

    PubMed

    Anda, G; Dunai, D; Lampert, M; Krizsanóczi, T; Németh, J; Bató, S; Nam, Y U; Hu, G H; Zoletnik, S

    2018-01-01

    A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

  18. Development of a high current 60 keV neutral lithium beam injector for beam emission spectroscopy measurements on fusion experiments

    NASA Astrophysics Data System (ADS)

    Anda, G.; Dunai, D.; Lampert, M.; Krizsanóczi, T.; Németh, J.; Bató, S.; Nam, Y. U.; Hu, G. H.; Zoletnik, S.

    2018-01-01

    A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

  19. Health care sensor--based systems for point of care monitoring and diagnostic applications: a brief survey.

    PubMed

    Tsakalakis, Michail; Bourbakis, Nicolaos G

    2014-01-01

    Continuous, real-time remote monitoring through medical point--of--care (POC) systems appears to draw the interest of the scientific community for healthcare monitoring and diagnostic applications the last decades. Towards this direction a significant merit has been due to the advancements in several scientific fields. Portable, wearable and implantable apparatus may contribute to the betterment of today's healthcare system which suffers from fundamental hindrances. The number and heterogeneity of such devices and systems regarding both software and hardware components, i.e sensors, antennas, acquisition circuits, as well as the medical applications that are designed for, is impressive. Objective of the current study is to present the major technological advancements that are considered to be the driving forces in the design of such systems, to briefly state the new aspects they can deliver in healthcare and finally, the identification, categorization and a first level evaluation of them.

  20. Point-of-care testing system enabling 30 min detection of influenza genes.

    PubMed

    Abe, Tomoteru; Segawa, Yuji; Watanabe, Hidetoshi; Yotoriyama, Tasuku; Kai, Shinichi; Yasuda, Akio; Shimizu, Norio; Tojo, Naoko

    2011-03-21

    We developed a portable and easy-to-use nucleic acid amplification test (NAT) system for use in point-of-care testing (POCT). The system shows sensitivity that is sufficiently higher than that of the currently available rapid diagnostic kit and is comparable to that of real-time reverse transcription polymerase chain reaction (RT-PCR) for influenza testing. This journal is © The Royal Society of Chemistry 2011

  1. A new beam diagnostic system for the MASHA setup

    NASA Astrophysics Data System (ADS)

    Motycak, S.; Rodin, A. M.; Novoselov, A. S.; Podshibyakin, A. V.; Krupa, L.; Belozerov, A. V.; Vedeneyev, V. Yu.; Gulyaev, A. V.; Gulyaeva, A. V.; Kliman, J.; Salamatin, V. S.; Stepantsov, S. V.; Chernysheva, E. V.; Yuchimchuk, S. A.; Komarov, A. B.; Kamas, D.

    2016-09-01

    A new beam diagnostic system based on the PXI standard was developed, tested, and used in the MASHA setup experiment. The beam energy and beam current measurements were carried out using several methods. The online time-of-flight energy measurements were carried out using three pick-up detectors. We used two electronic systems to measure the time between the pick-ups. The first system was based on fast Agilent digitizers (2-channel, 4-GHz sampling rate), and the second one was based on a constant fraction discriminator (CFD) connected to a time-to-digital converter (TDC, 5-ps resolution). A new graphical interface to monitor the electronic devices and to perform the online calculations of energy was developed using MFC C++. The second system based on microchannel plate (time-of-flight) and silicon detectors for the determination of beam energy and the type of accelerated particles was also used. The beam current measurements were carried out with two different sensors. The first sensor is a rotating Faraday cup placed in front of the target, and the second one is an emission detector installed at the rear of the target. This system is now used in experiments for the synthesis of superheavy elements at the U400M cyclotron of the Flerov Laboratory of Nuclear Reactions (FLNR).

  2. Diagnostic-management system and test pulse acquisition for WEST plasma measurement system

    NASA Astrophysics Data System (ADS)

    Wojenski, A.; Kasprowicz, G.; Pozniak, K. T.; Byszuk, A.; Juszczyk, B.; Zabolotny, W.; Zienkiewicz, P.; Chernyshova, M.; Czarski, T.; Mazon, D.; Malard, P.

    2014-11-01

    This paper describes current status of electronics, firmware and software development for new plasma measurement system for use in WEST facility. The system allows to perform two dimensional plasma visualization (in time) with spectrum measurement. The analog front-end is connected to Gas Electron Multiplier detector (GEM detector). The system architecture have high data throughput due to use of PCI-Express interface, Gigabit Transceivers and sampling frequency of ADC integrated circuits. The hardware is based on several years of experience in building X-ray spectrometer system for Joint European Torus (JET) facility. Data streaming is done using Artix7 FPGA devices. The system in basic configuration can work with up to 256 channels, while the maximum number of measurement channels is 2048. Advanced firmware for the FPGA is required in order to perform high speed data streaming and analog signal sampling. Diagnostic system management has been developed in order to configure measurement system, perform necessary calibration and prepare hardware for data acquisition.

  3. Current audiological diagnostics

    PubMed Central

    Hoth, Sebastian; Baljić, Izet

    2017-01-01

    Today’s audiological functional diagnostics is based on a variety of hearing tests, whose large number takes account of the variety of malfunctions of a complex sensory organ system and the necessity to examine it in a differentiated manner and at any age of life. The objective is to identify nature and origin of the hearing loss and to quantify its extent as far as necessary to dispose of the information needed to initiate the adequate medical (conservative or operational) treatment or the provision with technical hearing aids or prostheses. Moreover, audiometry provides the basis for the assessment of impairment and handicap as well as for the calculation of the degree of disability. In the present overview, the current state of the method inventory available for practical use is described, starting from basic diagnostics over to complex special techniques. The presentation is systematically grouped in subjective procedures, based on psychoacoustic exploration, and objective methods, based on physical measurements: preliminary hearing tests, pure tone threshold, suprathreshold processing of sound intensity, directional hearing, speech understanding in quiet and in noise, dichotic hearing, tympanogram, acoustic reflex, otoacoustic emissions and auditory evoked potentials. Apart from a few still existing gaps, this method inventory covers the whole spectrum of all clinically relevant functional deficits of the auditory system. PMID:29279727

  4. Direct measurements of safety factor profiles with motional Stark effect for KSTAR tokamak discharges with internal transport barriers

    NASA Astrophysics Data System (ADS)

    Ko, J.; Chung, J.

    2017-06-01

    The safety factor profile evolutions have been measured from the plasma discharges with the external current drive mechanism such as the multi-ion-source neutral beam injection for the Korea Superconducting Tokamak Advanced Research (KSTAR) for the first time. This measurement has been possible by the newly installed motional Stark effect (MSE) diagnostic system that utilizes the polarized Balmer-alpha emission from the energetic neutral deuterium atoms induced by the Stark effect under the Lorentz electric field. The 25-channel KSTAR MSE diagnostic is based on the conventional photoelastic modulator approach with the spatial and temporal resolutions less than 2 cm (for the most of the channels except 2 to 3 channels inside the magnetic axis) and about 10 ms, respectively. The strong Faraday rotation imposed on the optical elements in the diagnostic system is calibrated out from a separate and well-designed polarization measurement procedure using an in-vessel reference polarizer during the toroidal-field ramp-up phase before the plasma experiment starts. The combination of the non-inductive current drive during the ramp-up and shape control enables the formation of the internal transport barrier where the pitch angle profiles indicate flat or slightly hollow profiles in the safety factor.

  5. A Statistically Based Training Diagnostic Tool for Marine Aviation

    DTIC Science & Technology

    2014-06-01

    mission essential task list MDG maneuver description guide MOS military occupational specialty MSHARP Marine Sierra Hotel Aviation Reporting Program...include the Defense Readiness Reporting System (DRRS) Marine Corps, the Current Readiness Program (CRP), and the Marine Sierra Hotel Aviation...Beuschel, 2008). Many of these systems focus on business decisions regarding how companies can increase their bottom line, by appealing to customers more

  6. Rotor Smoothing and Vibration Monitoring Results for the US Army VMEP

    DTIC Science & Technology

    2009-06-01

    individual component CI detection thresholds, and development of models for diagnostics, prognostics , and anomaly detection . Figure 16 VMEP Server...and prognostics are of current interest. Development of those systems requires large amounts of data (collection, monitoring , manipulation) to capture...development of automated systems and for continuous updating of algorithms to improve detection , classification, and prognostic performance. A test

  7. Ultrasound and MRI of nerves for monitoring disease activity and treatment effects in chronic dysimmune neuropathies - Current concepts and future directions.

    PubMed

    Décard, Bernhard F; Pham, Mirko; Grimm, Alexander

    2018-01-01

    New imaging modalities like high-resolution-ultrasound (HRUS) and MR-Neurography (MRN) are increasingly used for the evaluation of the peripheral nervous system. The increasing knowledge on morphological changes observed in different neuropathies has led to a better understanding of underlying pathophysiological processes. The diagnosis of acquired chronic dysimmune neuropathies (CDN) like chronic inflammatory demyelinating polyneuropathy (CIDP), Lewis-Sumner Syndrome (LSS) or multifocal motor neuropathy (MMN) can be challenging. The current diagnostic criteria and outcome parameters are mainly based on clinical and electrophysiological parameters. Especially in CDN cases with atypical presentation or during early disease stages, the diagnostic accuracy is low and standardized protocols for the evaluation of disease activity and treatment response are lacking. The establishment of combined diagnostic criteria for CDN including imaging modalities could help to improve the diagnostic accuracy, allow a better differentiation of subtypes and facilitate the follow-up of disease course. The appropriate selection of eligible patients and sensitive monitoring of treatment response is mandatory future in treatment trials. In this article, we briefly summarize the clinical presentations and pathophysiological concepts of different CDN like CIDP, LSS and MMN. Furthermore, this review focuses on the diagnostic value of HRUS/MRN and its potential role for the monitoring of disease activity. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  8. Xpert®MTB/RIF for the Diagnosis of Tuberculosis in a Remote Arctic Setting: Impact on Cost and Time to Treatment Initiation.

    PubMed

    Oxlade, Olivia; Sugarman, Jordan; Alvarez, Gonzalo G; Pai, Madhukar; Schwartzman, Kevin

    2016-01-01

    Tuberculosis (TB) remains a significant health problem in the Canadian Arctic. Substantial health system delays in TB diagnosis can occur, in part due to the lack of capacity for onsite microbiologic testing. A study recently evaluated the yield and impact of a rapid automated PCR test (Xpert®MTB/RIF) for the diagnosis of TB in Iqaluit (Nunavut). We conducted an economic analysis to evaluate the expected cost relative to the expected reduction in time to treatment initiation, with the addition of Xpert®MTB/RIF to the current diagnostic and treatment algorithms used in this setting. A decision analysis model compared current microbiologic testing to a scenario where Xpert®MTB/RIF was added to the current diagnostic algorithm for active TB, and incorporated costs and clinical endpoints from the Iqaluit study. Several sensitivity analyses that considered alternative use were also considered. We estimated days to TB diagnosis and treatment initiation, health system costs, and the incremental cost per treatment day gained for each individual evaluated for possible TB. With the addition of Xpert®MTB/RIF, costs increased while days to TB treatment initiation were reduced. The incremental cost per treatment day gained (per individual investigated for TB) was $164 (95% uncertainty range $85, $452). In a sensitivity analysis that considered hospital discharge after a single negative Xpert®MTB/RIF, the Xpert®MTB/RIF scenario was cost saving. Adding Xpert®MTB/RIF to the current diagnostic algorithm for TB in Nunavut appears to reduce time to diagnosis and treatment at reasonable cost. It may be especially well suited to overcome some of the other logistical barriers that are unique to this and other remote communities.

  9. Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test

    NASA Technical Reports Server (NTRS)

    Huang, Wensheng; Kamhawi, Hani; Shastry, Rohit

    2012-01-01

    There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.

  10. Optical diagnostics of the arc plasma using fast intensified CCD-spectrograph system

    NASA Astrophysics Data System (ADS)

    Pavelescu, Gabriela; Guillot, Stephane; Braic, Mariana T.; Hong, Dunpin; Pavelescu, D.; Fleurier, Claude; Braic, Viorel; Gherendi, F.; Dumitrescu, G.; Anghelita, P.; Bauchire, J. M.

    2004-10-01

    Spectroscopic diagnostics, using intensified high speed CCD camera, was applied to study the arc dynamics in low voltage circuit breakers, in vacuum and in air. Time-resolved emission spectroscopy of the vacuum arc plasma, generated during electrode separation, provided information about the interruption process. The investigations were focused on the partial unsuccessful interruption around current zero. Absorption spectroscopy, in a peculiar setup, was used in order to determine the metallic atoms densities in the interelectrode space of a low voltage circuit breaker, working in ambient air.

  11. Fast-ion Dα spectrum diagnostic in the EAST

    NASA Astrophysics Data System (ADS)

    Hou, Y. M.; Wu, C. R.; Huang, J.; Heidbrink, W. W.; von Hellermann, M. G.; Xu, Z.; Jin, Z.; Chang, J. F.; Zhu, Y. B.; Gao, W.; Chen, Y. J.; Lyu, B.; Hu, R. J.; Zhang, P. F.; Zhang, L.; Gao, W.; Wu, Z. W.; Yu, Y.; Ye, M. Y.

    2016-11-01

    In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.

  12. The real time multi point Thomson scattering diagnostic at NSTX-U

    NASA Astrophysics Data System (ADS)

    Laggner, Florian; Kolemen, Egemen; Diallo, Ahmed; Leblanc, Benoit; Rozenblat, Roman; Tchilinguirian, Greg; NSTX-U Team Team

    2017-10-01

    This contribution presents the upgrade of the multi point Thomson scattering (MPTS) diagnostic for real time application. As a key diagnostic at NSTX-U, the MPTS diagnostic simultaneously measures the electron density (ne) and electron temperature (Te) profiles of a plasma discharge. Therefore, this powerful diagnostic can directly access the electron pressure of the plasma. Currently, only post-discharge evaluation of the data is available, however, since the plasma pressure is one important drive for instabilities, real time measurements of this quantities would be beneficial for plasma control. In a first step, ten MPTS channels were equipped with real time electronics, which improve the data acquisition rate by five orders of magnitude. The commissioning of the system is ongoing and first benchmarks of the real time evaluation routines against the standard, post-discharge evaluation show promising results: The Te as well as ne profiles of both types of analyses agree within their uncertainties. This work was supported by the US Department of Energy under DE-SC0015878 and DE-SC0015480.

  13. Soft X-ray tomography in support of impurity control in tokamaks

    NASA Astrophysics Data System (ADS)

    Mlynar, J.; Mazon, D.; Imrisek, M.; Loffelmann, V.; Malard, P.; Odstrcil, T.; Tomes, M.; Vezinet, D.; Weinzettl, V.

    2016-10-01

    This contribution reviews an important example of current developments in diagnostic systems and data analysis tools aimed at improved understanding and control of transport processes in magnetically confined high temperature plasmas. The choice of tungsten for the plasma facing components of ITER and probably also DEMO means that impurity control in fusion plasmas is now a crucial challenge. Soft X-ray (SXR) diagnostic systems serve as a key sensor for experimental studies of plasma impurity transport with a clear prospective of its control via actuators based mainly on plasma heating systems. The SXR diagnostic systems typically feature high temporal resolution but limited spatial resolution due to access restrictions. In order to reconstruct the spatial distribution of the SXR radiation from line integrated measurements, appropriate tomographic methods have been developed and validated, while novel numerical methods relevant for real-time control have been proposed. Furthermore, in order to identify the main contributors to the SXR plasma radiation, at least partial control over the spectral sensitivity range of the detectors would be beneficial, which motivates for developments of novel SXR diagnostic methods. Last, but not least, semiconductor photosensitive elements cannot survive in harsh conditions of future fusion reactors due to radiation damage, which calls for development of radiation hard SXR detectors. Present research in this field is exemplified on recent results from tokamaks COMPASS, TORE SUPRA and the Joint European Torus JET. Further planning is outlined.

  14. Intelligent monitoring of critical pathological events during anesthesia.

    PubMed

    Gohil, Bhupendra; Gholamhhosseini, Hamid; Harrison, Michael J; Lowe, Andrew; Al-Jumaily, Ahmed

    2007-01-01

    Expert algorithms in the field of intelligent patient monitoring have rapidly revolutionized patient care thereby improving patient safety. Patient monitoring during anesthesia requires cautious attention by anesthetists who are monitoring many modalities, diagnosing clinically critical events and performing patient management tasks simultaneously. The mishaps that occur during day-to-day anesthesia causing disastrous errors in anesthesia administration were classified and studied by Reason [1]. Human errors in anesthesia account for 82% of the preventable mishaps [2]. The aim of this paper is to develop a clinically useful diagnostic alarm system for detecting critical events during anesthesia administration. The development of an expert diagnostic alarm system called ;RT-SAAM' for detecting critical pathological events in the operating theatre is presented. This system provides decision support to the anesthetist by presenting the diagnostic results on an integrative, ergonomic display and thus enhancing patient safety. The performance of the system was validated through a series of offline and real-time testing in the operation theatre. When detecting absolute hypovolaemia (AHV), moderate level of agreement was observed between RT-SAAM and the human expert (anesthetist) during surgical procedures. RT-SAAM is a clinically useful diagnostic tool which can be easily modified for diagnosing additional critical pathological events like relative hypovolaemia, fall in cardiac output, sympathetic response and malignant hyperpyrexia during surgical procedures. RT-SAAM is currently being tested at the Auckland City Hospital with ethical approval from the local ethics committees.

  15. Applications and Experiences

    NASA Astrophysics Data System (ADS)

    Sacco, Giovanni Maria; Ferré, Sébastien

    This chapter discusses a number of real-world applications of dynamic taxonomies. Most current applications are object-seeking or knowledge-seeking exploratory tasks, and address important areas such as e-commerce, multimedia infobases, diagnostic systems, digital libraries and news systems, e-government, file systems, and geographical information systems. Applications in these areas are discussed in detail in the following, and applications in cultural heritage, art and architecture, e-recruitment, e-hrm, e-matchmaking, e-health, and e-learning are briefly reviewed.

  16. Multiparametric prostate MRI: technical conduct, standardized report and clinical use.

    PubMed

    Manfredi, Matteo; Mele, Fabrizio; Garrou, Diletta; Walz, Jochen; Fütterer, Jurgen J; Russo, Filippo; Vassallo, Lorenzo; Villers, Arnauld; Emberton, Mark; Valerio, Massimo

    2018-02-01

    Multiparametric prostate MRI (mp-MRI) is an emerging imaging modality for diagnosis, characterization, staging, and treatment planning of prostate cancer (PCa). The technique, results reporting, and its role in clinical practice have been the subject of significant development over the last decade. Although mp-MRI is not yet routinely used in the diagnostic pathway, almost all urological guidelines have emphasized the potential role of mp-MRI in several aspects of PCa management. Moreover, new MRI sequences and scanning techniques are currently under evaluation to improve the diagnostic accuracy of mp-MRI. This review presents an overview of mp-MRI, summarizing the technical applications, the standardized reporting systems used, and their current roles in various stages of PCa management. Finally, this critical review also reports the main limitations and future perspectives of the technique.

  17. Crack identification for reinforced concrete using PZT based smart rebar active sensing diagnostic network

    NASA Astrophysics Data System (ADS)

    Song, N. N.; Wu, F.

    2016-04-01

    An active sensing diagnostic system using PZT based smart rebar for SHM of RC structure has been currently under investigation. Previous test results showed that the system could detect the de-bond of concrete from reinforcement, and the diagnostic signals were increased exponentially with the de-bonding size. Previous study also showed that the smart rebar could function well like regular reinforcement to undertake tension stresses. In this study, a smart rebar network has been used to detect the crack damage of concrete based on guided waves. Experimental test has been carried out for the study. In the test, concrete beams with 2 reinforcements have been built. 8 sets of PZT elements were mounted onto the reinforcement bars in an optimized way to form an active sensing diagnostic system. A 90 kHz 5-cycle Hanning-windowed tone burst was used as input. Multiple cracks have been generated on the concrete structures. Through the guided bulk waves propagating in the structures from actuators and sensors mounted from different bars, crack damage could be detected clearly. Cases for both single and multiple cracks were tested. Different crack depths from the surface and different crack numbers have been studied. Test result shows that the amplitude of sensor output signals is deceased linearly with a propagating crack, and is decreased exponentially with increased crack numbers. From the study, the active sensing diagnostic system using PZT based smart rebar network shows a promising way to provide concrete crack damage information through the "talk" among sensors.

  18. Improvement of malaria diagnostic system based on acridine orange staining.

    PubMed

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  19. Measuring the spacecraft and environmental interactions of the 8-cm mercury ion thrusters on the P80-1 mission

    NASA Technical Reports Server (NTRS)

    Power, J. L.

    1981-01-01

    The subject interface measurements are described for the Ion Auxiliary Propulsion System (IAPS) flight test of two 8-cm thrusters. The diagnostic devices and the effects to be measured include: 1) quartz crystal microbalances to detect nonvolatile deposition due to thruster operation; 2) warm and cold solar cell monitors for nonvolatile and volatile (mercury) deposition; 3) retarding potential ion collectors to characterize the low energy thruster ionic efflux; and 4) a probe to measure the spacecraft potential and thruster generated electron currents to biased spacecraft surfaces. The diagnostics will also assess space environmental interactions of the spacecraft and thrusters. The diagnostic data will characterize mercury thruster interfaces and provide data useful for future applications.

  20. A review of current and future molecular diagnostic tests for use in the microbiology laboratory.

    PubMed

    Jannes, Geert; De Vos, Daniel

    2006-01-01

    Nucleic acid-based diagnostics gradually are replacing or complementing culture-based, biochemical, and immunological assays in routine microbiology laboratories. Similar to conventional tests, the first-generation deoxyribonucleic acid assays determined only a single analyte. Recent improvements in detection technologies have paved the way for the development of multiparameter assays using macroarrays or micro-arrays, while the introduction of closed-tube real-time polymerase chain reaction systems has resulted in the development of rapid microbial diagnostics with a reduced contamination risk. The use of these new molecular technologies is not restricted to detection and identification of microbial pathogens but also can be used for genotyping, allowing one to determine antibiotic resistance or to perform microbial fingerprinting.

  1. SMART Layer and SMART Suitcase for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Lin, Mark; Qing, Xinlin; Kumar, Amrita; Beard, Shawn J.

    2001-06-01

    Knowledge of integrity of in-service structures can greatly enhance their safety and reliability and lower structural maintenance cost. Current practices limit the extent of real-time knowledge that can be obtained from structures during inspection, are labor-intensive and thereby increase life-cycle costs. Utilization of distributed sensors integrated with the structure is a viable and cost-effective means of monitoring the structure and reducing inspection costs. Acellent Technologies is developing a novel system for actively and passively interrogating the health of a structure through an integrated network of sensors and actuators. Acellent's system comprises of SMART Layers, SMART Suitcase and diagnostic software. The patented SMART Layer is a thin dielectric film with an embedded network of distributed piezoelectric actuators/sensors that can be surface-mounted on metallic structures or embedded inside composite structures. The SMART Suitcase is a portable diagnostic unit designed with multiple sensor/actuator channels to interface with the SMART Layer, generate diagnostic signals from actuators and record measurements from the embedded sensors. With appropriate diagnostic software, Acellent's system can be used for monitoring structural condition and for detecting damage while the structures are in service. This paper enumerates on the SMART Layer and SMART Suitcase and their applicability to composite and metal structures.

  2. Lunar Surface Reference Missions: A Description of Human and Robotic Surface Activities

    NASA Technical Reports Server (NTRS)

    Duke, Michael B.; Hoffman, Stephen J.; Snook, Kelly

    2003-01-01

    Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.

  3. Evidentiary Reasoning in Diagnostic Classification Models

    ERIC Educational Resources Information Center

    Levy, Roy

    2009-01-01

    In "Unique Characteristics of Diagnostic Classification Models: A Comprehensive Review of the Current State-of-the-Art," Rupp and Templin (2008) undertake the ambitious task of providing a thorough portrait of the current state of diagnostic classification models (DCM). In this commentary, the author applauds Rupp and Templin for their…

  4. Gear noise, vibration, and diagnostic studies at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Zakrajsek, James J.; Oswald, Fred B.; Townsend, Dennis P.; Coy, John J.

    1990-01-01

    The NASA Lewis Research Center and the U.S. Army Aviation Systems Command are involved in a joint research program to advance the technology of rotorcraft transmissions. This program consists of analytical as well as experimental efforts to achieve the overall goals of reducing weight, noise, and vibration, while increasing life and reliability. Recent analytical activities are highlighted in the areas of gear noise, vibration, and diagnostics performed in-house and through NASA and U.S. Army sponsored grants and contracts. These activities include studies of gear tooth profiles to reduce transmission error and vibration as well as gear housing and rotordynamic modeling to reduce structural vibration transmission and noise radiation, and basic research into current gear failure diagnostic methodologies. Results of these activities are presented along with an overview of near term research plans in the gear noise, vibration, and diagnostics area.

  5. The Evolution of TMD Diagnosis

    PubMed Central

    Ohrbach, R.; Dworkin, S.F.

    2016-01-01

    This review explores the principles and process associated with the diagnosis of temporomandibular disorders (TMDs). TMD diagnosis has evolved substantially over the past 25 y. Previously, diagnosis focused solely on aberrations in oral structures, largely without empirical evidence. The Research Diagnostic Criteria for TMD (RDC/TMD) were developed on core principles of 1) a dual-axis system reflecting the biopsychosocial model, 2) a clear operationalization for reliability, and 3) the allowance of multiple diagnoses. These principles were retained in the subsequent validation research of the RDC/TMD, and the current diagnostic system—the Diagnostic Criteria for TMD (DC/TMD)—has improved on those principles as well as on diagnostic validity and protocols for assessing the psychosocial domain. Further investigations into etiology and its potential contribution to taxonomy revision are described, particularly within the context of complex disease. The review concludes with an outline of major research areas already underway that will support future revisions of the DC/TMD. PMID:27313164

  6. A WAO - ARIA - GA²LEN consensus document on molecular-based allergy diagnostics

    PubMed Central

    2013-01-01

    Molecular-based allergy (MA) diagnostics is an approach used to map the allergen sensitization of a patient at a molecular level, using purified natural or recombinant allergenic molecules (allergen components) instead of allergen extracts. Since its introduction, MA diagnostics has increasingly entered routine care, with currently more than 130 allergenic molecules commercially available for in vitro specific IgE (sIgE) testing. MA diagnostics allows for an increased accuracy in allergy diagnosis and prognosis and plays an important role in three key aspects of allergy diagnosis: (1) resolving genuine versus cross-reactive sensitization in poly-sensitized patients, thereby improving the understanding of triggering allergens; (2) assessing, in selected cases, the risk of severe, systemic versus mild, local reactions in food allergy, thereby reducing unnecessary anxiety for the patient and the need for food challenge testing; and (3) identifying patients and triggering allergens for specific immunotherapy (SIT). Singleplex and multiplex measurement platforms are available for MA diagnostics. The Immuno-Solid phase Allergen Chip (ISAC) is the most comprehensive platform currently available, which involves a biochip technology to measure sIgE antibodies against more than one hundred allergenic molecules in a single assay. As the field of MA diagnostics advances, future work needs to focus on large-scale, population-based studies involving practical applications, elucidation and expansion of additional allergenic molecules, and support for appropriate test interpretation. With the rapidly expanding evidence-base for MA diagnosis, there is a need for allergists to keep abreast of the latest information. The aim of this consensus document is to provide a practical guide for the indications, determination, and interpretation of MA diagnostics for clinicians trained in allergology. PMID:24090398

  7. A WAO - ARIA - GA²LEN consensus document on molecular-based allergy diagnostics.

    PubMed

    Canonica, Giorgio Walter; Ansotegui, Ignacio J; Pawankar, Ruby; Schmid-Grendelmeier, Peter; van Hage, Marianne; Baena-Cagnani, Carlos E; Melioli, Giovanni; Nunes, Carlos; Passalacqua, Giovanni; Rosenwasser, Lanny; Sampson, Hugh; Sastre, Joaquin; Bousquet, Jean; Zuberbier, Torsten

    2013-10-03

    Molecular-based allergy (MA) diagnostics is an approach used to map the allergen sensitization of a patient at a molecular level, using purified natural or recombinant allergenic molecules (allergen components) instead of allergen extracts. Since its introduction, MA diagnostics has increasingly entered routine care, with currently more than 130 allergenic molecules commercially available for in vitro specific IgE (sIgE) testing.MA diagnostics allows for an increased accuracy in allergy diagnosis and prognosis and plays an important role in three key aspects of allergy diagnosis: (1) resolving genuine versus cross-reactive sensitization in poly-sensitized patients, thereby improving the understanding of triggering allergens; (2) assessing, in selected cases, the risk of severe, systemic versus mild, local reactions in food allergy, thereby reducing unnecessary anxiety for the patient and the need for food challenge testing; and (3) identifying patients and triggering allergens for specific immunotherapy (SIT).Singleplex and multiplex measurement platforms are available for MA diagnostics. The Immuno-Solid phase Allergen Chip (ISAC) is the most comprehensive platform currently available, which involves a biochip technology to measure sIgE antibodies against more than one hundred allergenic molecules in a single assay. As the field of MA diagnostics advances, future work needs to focus on large-scale, population-based studies involving practical applications, elucidation and expansion of additional allergenic molecules, and support for appropriate test interpretation. With the rapidly expanding evidence-base for MA diagnosis, there is a need for allergists to keep abreast of the latest information. The aim of this consensus document is to provide a practical guide for the indications, determination, and interpretation of MA diagnostics for clinicians trained in allergology.

  8. Space Shuttle main engine OPAD: The search for a hardware enhanced plume

    NASA Astrophysics Data System (ADS)

    Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.

    1993-11-01

    The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.

  9. Space Shuttle main engine OPAD: The search for a hardware enhanced plume

    NASA Technical Reports Server (NTRS)

    Powers, W. T.; Cooper, A. E.; Wallace, Tim L.; Buntine, W. L.; Whitaker, K. W.

    1993-01-01

    The process of applying spectroscopy to the Space Shuttle Main Engine (SSME) for plume diagnostics, as it exists today, originated at Marshall Space Flight Center in Huntsville, Alabama, and its implementation was assured largely through the efforts of Sverdrup AEDC, in Tullahoma, Tennessee. This team continues to lead and guide efforts in the plume diagnostics arena. The process, Optical Plume Anomaly Detection (OPAD), formed the basis for various activities in the development of ground-based systems as well as the development of in-flight plume spectroscopy. OPAD currently provides and will continue to provide valuable information relative to future systems definitions, instrumentation development, code validation, and data diagnostic processing. OPAD is based on the detection of anomalous atomic and molecular species in the SSME plume using two complete, stand-alone optical spectrometers. To-date OPAD has acquired data on 44 test firings of the SSME at the Technology Test Bed (TTB) at MSFC. The purpose of this paper will be to provide an introduction to the OPAD system by discussing the process of obtaining data as well as the methods of examining and interpreting the data. It will encompass such issues as selection of instrumentation correlation of data to nominal engine operation, investigation of SSME component erosion via OPAD spectral data, necessity and benefits of plume seeding, application of artificial intelligence (AI) techniques to data analysis, and the present status of efforts to quantify specie erosion utilizing standard plume and chemistry codes as well as radiative models currently under development.

  10. Vascular tumors of the choroid and retina

    PubMed Central

    Shanmugam, P Mahesh; Ramanjulu, Rajesh

    2015-01-01

    Vascular tumors of the retina and choroid can be seen occasionally. In the following article, the key clinical and diagnostic features of the major retinal and choroidal vascular tumors, their systemic associations, and the literature pertaining to the most currently available treatment strategies are reviewed. PMID:25827544

  11. Diagnostic classification past, present, and future: implications for pharmacotherapy.

    PubMed

    Howland, Robert H

    2013-04-01

    Making a diagnosis is a key step in understanding the natural course of a disorder, selecting an appropriate treatment for the disorder, and predicting its response to treatment. Diagnostic proposals can be evaluated in two ways: reliability and validity. The reliability and validity of diagnoses are not one and the same, although establishing reliability is usually a necessary step before being able to evaluate and determine validity. There is little evidence that most psychiatric diagnoses are valid, but the reliability of diagnoses using classification systems developed since 1970 have greatly improved and are important for clinical practice and research. Past and current diagnostic systems have not optimally assisted the search for disorder-specific pathophysiological mechanisms, and they do not provide the specificity that clinicians would like when selecting medication. The Research Domain Criteria project is intended to shift research away from categorical diagnoses to focus on dysregulated neurobiological systems, and this approach ultimately may be more useful for understanding the pathophysiology of mental disorders and improving the development and use of treatment interventions. Copyright 2013, SLACK Incorporated.

  12. SYN-PEDS: SYNtactical Pediatric Evaluation and Diagnostic System

    PubMed Central

    Witten, Matthew; Maloney, David

    1980-01-01

    SYN-PEDS is a multimodular system which is designed to be an inhome interactive access to a neonatal and pediatric diagnostic information database. This system is designed to assist a parent in assessing his child's condition, as well as in determining whether or not the child needs immediate medical attention. This system is not designed to replace the pediatrician but rather, it is designed as a preventative and health maintenance information system which has the unusually nice side benefit if helping to reduce medical system costs by cutting down on the number of unnecessary visits to private and local clinics as well as private physicians. The current version of SYN-PEDS is composed of of four operative modules: CRITICAL, TREAT, CLINFO, and DIAGNOSE/SYMPTM. These four modules allow the parent/user to interact with the SYN-PEDS system in various modes. As an example, CLINFO is the module which provides clinical information on a variety of subjects. This module is for a parent who wishes information on a particular subject of interest.

  13. GENE-07. MOLECULAR NEUROPATHOLOGY 2.0 - INCREASING DIAGNOSTIC ACCURACY IN PEDIATRIC NEUROONCOLOGY

    PubMed Central

    Sturm, Dominik; Jones, David T.W.; Capper, David; Sahm, Felix; von Deimling, Andreas; Rutkoswki, Stefan; Warmuth-Metz, Monika; Bison, Brigitte; Gessi, Marco; Pietsch, Torsten; Pfister, Stefan M.

    2017-01-01

    Abstract The classification of central nervous system (CNS) tumors into clinically and biologically distinct entities and subgroups is challenging. Children and adolescents can be affected by >100 histological variants with very variable outcomes, some of which are exceedingly rare. The current WHO classification has introduced a number of novel molecular markers to aid routine neuropathological diagnostics, and DNA methylation profiling is emerging as a powerful tool to distinguish CNS tumor classes. The Molecular Neuropathology 2.0 study aims to integrate genome wide (epi-)genetic diagnostics with reference neuropathological assessment for all newly-diagnosed pediatric brain tumors in Germany. To date, >350 patients have been enrolled. A molecular diagnosis is established by epigenetic tumor classification through DNA methylation profiling and targeted panel sequencing of >130 genes to detect diagnostically and/or therapeutically useful DNA mutations, structural alterations, and fusion events. Results are aligned with the reference neuropathological diagnosis, and discrepant findings are discussed in a multi-disciplinary tumor board including reference neuroradiological evaluation. Ten FFPE sections as input material are sufficient to establish a molecular diagnosis in >95% of tumors. Alignment with reference pathology results in four broad categories: a) concordant classification (~77%), b) discrepant classification resolvable by tumor board discussion and/or additional data (~5%), c) discrepant classification without currently available options to resolve (~8%), and d) cases currently unclassifiable by molecular diagnostics (~10%). Discrepancies are enriched in certain histopathological entities, such as histological high grade gliomas with a molecularly low grade profile. Gene panel sequencing reveals predisposing germline events in ~10% of patients. Genome wide (epi-)genetic analyses add a valuable layer of information to routine neuropathological diagnostics. Our study provides insight into CNS tumors with divergent histopathological and molecular classification, opening new avenues for research discoveries and facilitating optimization of clinical management for affected patients in the future.

  14. Clinical diagnosis and staging of cholangiocarcinoma

    PubMed Central

    Blechacz, Boris; Komuta, Mina; Roskams, Tania; Gores, Gregory J.

    2012-01-01

    Cholangiocarcinoma is the most frequent biliary malignancy. It is difficult to diagnose owing to its anatomic location, growth patterns and lack of definite diagnostic criteria. Currently, cholangiocarcinoma is classified into the following types according to its anatomic location along the biliary tree: intrahepatic, perihilar or distal extrahepatic cholangiocarcinoma. These cholangiocarcinoma types differ in their biological behavior and management. The appropriate stratification of patients with regard to the anatomic location and stage of cholangiocarcinoma is a key determinate in their management. Staging systems can guide this stratification and provide prognostic information. In addition, staging systems are essential in order to compare and contrast the outcomes of different therapeutic approaches. A number of staging systems exist for cholangiocarcinoma—several early ones have been updated, and new ones are being developed. We discuss the emerging diagnostic criteria as well as the different staging systems for cholangiocarcinoma, and provide a critical appraisal regarding these advances in biliary tract malignancies. PMID:21808282

  15. Ares I-X Ground Diagnostic Prototype

    NASA Technical Reports Server (NTRS)

    Schwabacher, Mark; Martin, Rodney; Waterman, Robert; Oostdyk, Rebecca; Ossenfort, John; Matthews, Bryan

    2010-01-01

    Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.

  16. Multiplexed Molecular Diagnostics for Respiratory, Gastrointestinal, and Central Nervous System Infections.

    PubMed

    Hanson, Kimberly E; Couturier, Marc Roger

    2016-11-15

    The development and implementation of highly multiplexed molecular diagnostic tests have allowed clinical microbiology laboratories to more rapidly and sensitively detect a variety of pathogens directly in clinical specimens. Current US Food and Drug Administration-approved multiplex panels target multiple different organisms simultaneously and can identify the most common pathogens implicated in respiratory viral, gastrointestinal, or central nervous system infections. This review summarizes the test characteristics of available assays, highlights the advantages and limitations of multiplex technology for infectious diseases, and discusses potential utilization of these new tests in clinical practice. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  17. A proposal for antiparallel acceleration of positrons using CEBAF

    DOE PAGES

    Tiefenback, M.; Wojtsekhowski, B.

    2018-05-01

    Here, we present a scheme for positron beam acceleration in CEBAF antiparallel to the normal electron path, requiring no change in polarity of the magnet systems. This feature is essential to the principal benefit: enabling extremely simple configuration changes between conventional (clockwise) e - acceleration and counter clockwise e + acceleration. Additionally, it appears possible to configure the accelerating cavity phases to support concurrent acceleration of the electron and positron beams. The last mode also may enable use of the higher peak current electron beam for system diagnostics. The inherent penalty of the concurrent mode in acceleration efficiency and increasedmore » energy spread may render this a commissioning-only diagnostic option, but the possibility appears worthy of consideration.« less

  18. A proposal for antiparallel acceleration of positrons using CEBAF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tiefenback, M.; Wojtsekhowski, B.

    Here, we present a scheme for positron beam acceleration in CEBAF antiparallel to the normal electron path, requiring no change in polarity of the magnet systems. This feature is essential to the principal benefit: enabling extremely simple configuration changes between conventional (clockwise) e - acceleration and counter clockwise e + acceleration. Additionally, it appears possible to configure the accelerating cavity phases to support concurrent acceleration of the electron and positron beams. The last mode also may enable use of the higher peak current electron beam for system diagnostics. The inherent penalty of the concurrent mode in acceleration efficiency and increasedmore » energy spread may render this a commissioning-only diagnostic option, but the possibility appears worthy of consideration.« less

  19. Charge Exchange Recombination Spectroscopy Based on Diagnostic Neutral Beam in HT-7 Tokamak

    NASA Astrophysics Data System (ADS)

    Shi, Yuejiang; Fu, Jia; Li, Yingying; William, Rowan; Huang, He; Wang, Fudi; Gao, Huixian; Huang, Juann; Zhou, Qian; Liu, Sheng; Zhang, Jian; Li, Jun; Xie, Yuanlai; Liu, Zhimin; Huang, Yiyun; Hu, Chundong; Wan, Baonian

    2010-02-01

    Charge exchange recombination spectroscopy (CXRS) based on a diagnostic neutral beam (DNB) installed in the HT-7 tokamak is introduced. DNB can provide a 6 A extracted current at 50 kV for 0.1 s in hydrogen. It can penetrate into the core plasma in HT-7. The CXRS system is designed to observe charge exchange (CX) transitions in the visible spectrum. CX light from the beam is focused onto 10 optical fibers, which view the plasma from -5 cm to 20 cm. The CXRS system can measure the ion temperature as low as 0.1 keV. With CXRS, the local ion temperature profile in HT-7 was obtained for the first time.

  20. ISHM-oriented adaptive fault diagnostics for avionics based on a distributed intelligent agent system

    NASA Astrophysics Data System (ADS)

    Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei

    2015-10-01

    In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.

  1. Computer Aided Diagnostic Support System for Skin Cancer: A Review of Techniques and Algorithms

    PubMed Central

    Masood, Ammara; Al-Jumaily, Adel Ali

    2013-01-01

    Image-based computer aided diagnosis systems have significant potential for screening and early detection of malignant melanoma. We review the state of the art in these systems and examine current practices, problems, and prospects of image acquisition, pre-processing, segmentation, feature extraction and selection, and classification of dermoscopic images. This paper reports statistics and results from the most important implementations reported to date. We compared the performance of several classifiers specifically developed for skin lesion diagnosis and discussed the corresponding findings. Whenever available, indication of various conditions that affect the technique's performance is reported. We suggest a framework for comparative assessment of skin cancer diagnostic models and review the results based on these models. The deficiencies in some of the existing studies are highlighted and suggestions for future research are provided. PMID:24575126

  2. Fighting the Whole System: Dissociative Identity Disorder, Labeling Theory, and Iatrogenic Doubting.

    PubMed

    Floris, Jessica; McPherson, Susan

    2015-01-01

    This research examines how individuals diagnosed with dissociative identity disorder construe their experiences of being labeled with a contested diagnosis. Semistructured interviews were conducted in the United Kingdom with 5 women and 2 men diagnosed with dissociative identity disorder. A framework analysis was conducted. The analysis identified 2 overarching themes: diagnosis cross-examined and navigating care systems. The diagnosis appeared to be continually assessed by participants for its fit with symptoms, and the doubt among professionals seemed to be unhelpfully reflected in participants' attempts to understand and come to terms with their experiences. The findings are considered in light of labeling theory, the iatrogenic effects of professional doubt, and current debates concerning the reliability and validity of psychiatric diagnostic systems that have been reinvigorated by the publication of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition.

  3. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 3; Acquire Express-A3 SPT-100 Based Propulsion Subsystem and Other Subsystem Flight Operation TM-Data for the Period of June 24, 2000 to and Including September 30, 2000, Task 30

    NASA Technical Reports Server (NTRS)

    Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  4. Hall Effect Thruster Interactions Data from the Russian Express-A2 and Express-A3 Satellites. Part 8; Acquire TM-Data for Type A and Type B Sensors for "Express A" Number 3 Satellite for the Period of January 1, 2001 to and Including March 31, 2001, Task 27C

    NASA Technical Reports Server (NTRS)

    Dunning, John (Technical Monitor); Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80deg E. and 11deg W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  5. Hall Effect Thruster Interactions Data From the Russian Express-A2 and Express-A3 Satellites. Part 10; Acquire TM-Data for Type A and Type B Sensors for "Express-A" Number 3 Satellite for the Period of July 1, 2001 to and Including September 30, 2001, Task 27D

    NASA Technical Reports Server (NTRS)

    Dunning, John (Technical Monitor); Sitnikova, N.; Volkov, D.; Maximov, I.; Petrusevich, V.; Allen, D.

    2003-01-01

    This 12-part report documents the data obtained from various sensor measurements taken aboard the Russian Express-A2 and Express-A3 spacecraft in Geosynchronous Earth Orbit (GEO). These GEO communications satellites, which were designed and built by NPO Prikladnoy Mekhaniki (NPO PM) of Zheleznogorsk, Russia, utilize Hall thruster propulsion systems for north-south and east-west stationkeeping and as of June 2002, were still operating at 80 E. and 11 W., respectively. Express-A2 was launched on March 12, 2000, while Express-A3 was launched on June 24, 2000. The diagnostic equipment from which these data were taken includes electric field strength sensors, ion current and energy sensors, and pressure sensors. The diagnostics and the Hall thruster propulsion systems are described in detail along with lists of tabular data from those diagnostics and propulsion system and other satellite systems. Space Power, Inc., now part of Pratt & Whitney's Chemical Systems Division, under contract NAS3 99151 to the NASA Glenn Research Center, obtained these data over several periods from March 12, 2000, through September 30, 2001. Each of the 12 individual reports describe, in detail, the propulsion systems as well as the diagnostic sensors utilized. Finally, parts 11 and 12 include the requirements to which NPO PM prepared and delivered these data.

  6. Anxiety Disorders in Childhood: Casting a Nomological Net

    ERIC Educational Resources Information Center

    Weems, Carl F.; Stickle, Timothy R.

    2005-01-01

    Empirical research highlights the need for improving the childhood anxiety disorder diagnostic classification system. In particular, inconsistencies in the stability estimates of childhood anxiety disorders and high rates of comorbidity call into the question the utility of the current "DSM" criteria. This paper makes a case for utilizing a…

  7. [Current macro-diagnostic trends of forensic medicine in the Czech Republic].

    PubMed

    Frišhons, Jan; Kučerová, Štěpánka; Jurda, Mikoláš; Sokol, Miloš; Vojtíšek, Tomáš; Hejna, Petr

    2017-01-01

    Over the last few years, advanced diagnostic methods have penetrated in the realm of forensic medicine in addition to standard autopsy techniques supported by traditional X-ray examination and macro-diagnostic laboratory tests. Despite the progress of imaging methods, the conventional autopsy has remained basic and essential diagnostic tool in forensic medicine. Postmortem computed tomography and magnetic resonance imaging are far the most progressive modern radio diagnostic methods setting the current trend of virtual autopsies all over the world. Up to now, only two institutes of forensic medicine have available postmortem computed tomography for routine diagnostic purposes in the Czech Republic. Postmortem magnetic resonance is currently unattainable for routine diagnostic use and was employed only for experimental purposes. Photogrammetry is digital method focused primarily on body surface imaging. Recently, the most fruitful results have been yielded from the interdisciplinary cooperation between forensic medicine and forensic anthropology with the implementation of body scanning techniques and 3D printing. Non-invasive and mini-invasive investigative methods such as postmortem sonography and postmortem endoscopy was unsystematically tested for diagnostic performance with good outcomes despite of limitations of these methods in postmortem application. Other futuristic methods, such as the use of a drone to inspect the crime scene are still experimental tools. The authors of the article present a basic overview of the both routinely and experimentally used investigative methods and current macro-diagnostic trends of the forensic medicine in the Czech Republic.

  8. Functional reasoning in diagnostic problem solving

    NASA Technical Reports Server (NTRS)

    Sticklen, Jon; Bond, W. E.; Stclair, D. C.

    1988-01-01

    This work is one facet of an integrated approach to diagnostic problem solving for aircraft and space systems currently under development. The authors are applying a method of modeling and reasoning about deep knowledge based on a functional viewpoint. The approach recognizes a level of device understanding which is intermediate between a compiled level of typical Expert Systems, and a deep level at which large-scale device behavior is derived from known properties of device structure and component behavior. At this intermediate functional level, a device is modeled in three steps. First, a component decomposition of the device is defined. Second, the functionality of each device/subdevice is abstractly identified. Third, the state sequences which implement each function are specified. Given a functional representation and a set of initial conditions, the functional reasoner acts as a consequence finder. The output of the consequence finder can be utilized in diagnostic problem solving. The paper also discussed ways in which this functional approach may find application in the aerospace field.

  9. The motional stark effect with laser-induced fluorescence diagnostic

    NASA Astrophysics Data System (ADS)

    Foley, E. L.; Levinton, F. M.

    2010-05-01

    The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (<1 T) experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.

  10. Diagnostic Reasoning using Prognostic Information for Unmanned Aerial Systems

    NASA Technical Reports Server (NTRS)

    Schumann, Johann; Roychoudhury, Indranil; Kulkarni, Chetan

    2015-01-01

    With increasing popularity of unmanned aircraft, continuous monitoring of their systems, software, and health status is becoming more and more important to ensure safe, correct, and efficient operation and fulfillment of missions. The paper presents integration of prognosis models and prognostic information with the R2U2 (REALIZABLE, RESPONSIVE, and UNOBTRUSIVE Unit) monitoring and diagnosis framework. This integration makes available statistically reliable health information predictions of the future at a much earlier time to enable autonomous decision making. The prognostic information can be used in the R2U2 model to improve diagnostic accuracy and enable decisions to be made at the present time to deal with events in the future. This will be an advancement over the current state of the art, where temporal logic observers can only do such valuation at the end of the time interval. Usefulness and effectiveness of this integrated diagnostics and prognostics framework was demonstrated using simulation experiments with the NASA Dragon Eye electric unmanned aircraft.

  11. Role of Raman spectroscopy and surface enhanced Raman spectroscopy in colorectal cancer

    PubMed Central

    Jenkins, Cerys A; Lewis, Paul D; Dunstan, Peter R; Harris, Dean A

    2016-01-01

    Colorectal cancer (CRC) is the fourth most common cancer in the United Kingdom and is the second largest cause of cancer related death in the United Kingdom after lung cancer. Currently in the United Kingdom there is not a diagnostic test that has sufficient differentiation between patients with cancer and those without cancer so the current referral system relies on symptomatic presentation in a primary care setting. Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are forms of vibrational spectroscopy that offer a non-destructive method to gain molecular information about biological samples. The techniques offer a wide range of applications from in vivo or in vitro diagnostics using endoscopic probes, to the use of micro-spectrometers for analysis of biofluids. The techniques have the potential to detect molecular changes prior to any morphological changes occurring in the tissue and therefore could offer many possibilities to aid the detection of CRC. The purpose of this review is to look at the current state of diagnostic technology in the United Kingdom. The development of Raman spectroscopy and SERS in clinical applications relation for CRC will then be discussed. Finally, future areas of research of Raman/SERS as a clinical tool for the diagnosis of CRC are also discussed. PMID:27190582

  12. Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations

    PubMed Central

    Mercante, Jeffrey W.

    2015-01-01

    SUMMARY Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic “blind spot” for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed. PMID:25567224

  13. Clinical Applications of Procalcitonin in Pediatrics: An Advanced Biomarker for Inflammation and Infection-Can It Also Be Used in Trauma?

    PubMed

    Koutroulis, Ioannis; Loscalzo, Steven M; Kratimenos, Panagiotis; Singh, Sabina; Weiner, Evan; Syriopoulou, Vassiliki; Theocharis, Stamatios; Chrousos, Georgios

    2014-01-01

    Background. Procalcitonin is a small molecular peptide that has gained increased support as an adjunct diagnostic marker of infection in the adult population; the concordant body of evidence for the use of procalcitonin in pediatric populations is far less complete. Objectives. Our objective is to review the current evidence supporting the utilization of procalcitonin in children in a variety of clinical scenarios including SIRS, sepsis, burns, and trauma and to identify existing knowledge gaps. Methods. A thorough review of the literature was performed utilizing PubMed. We focused on using meta-analysis from adult populations to review current practices in interpretation and methodology and find concordant pediatric studies to determine if the same applications are validated in pediatric populations. Results. Current evidence supports the usage of procalcitonin as both a sensitive and a specific marker for the differentiation of systemic inflammatory response syndrome from sepsis in pediatrics with increased diagnostic accuracy compared to commonly used biomarkers including complete blood counts and C-reactive protein. Conclusions. Although the body of evidence is limited, initial observations suggest that procalcitonin can be used in pediatric trauma and burn patients as both a prognostic and a diagnostic marker, aiding in the identification of infection in patients with extensive underlying inflammation.

  14. Clinical Applications of Procalcitonin in Pediatrics: An Advanced Biomarker for Inflammation and Infection—Can It Also Be Used in Trauma?

    PubMed Central

    Loscalzo, Steven M.; Singh, Sabina; Weiner, Evan; Syriopoulou, Vassiliki; Theocharis, Stamatios; Chrousos, Georgios

    2014-01-01

    Background. Procalcitonin is a small molecular peptide that has gained increased support as an adjunct diagnostic marker of infection in the adult population; the concordant body of evidence for the use of procalcitonin in pediatric populations is far less complete. Objectives. Our objective is to review the current evidence supporting the utilization of procalcitonin in children in a variety of clinical scenarios including SIRS, sepsis, burns, and trauma and to identify existing knowledge gaps. Methods. A thorough review of the literature was performed utilizing PubMed. We focused on using meta-analysis from adult populations to review current practices in interpretation and methodology and find concordant pediatric studies to determine if the same applications are validated in pediatric populations. Results. Current evidence supports the usage of procalcitonin as both a sensitive and a specific marker for the differentiation of systemic inflammatory response syndrome from sepsis in pediatrics with increased diagnostic accuracy compared to commonly used biomarkers including complete blood counts and C-reactive protein. Conclusions. Although the body of evidence is limited, initial observations suggest that procalcitonin can be used in pediatric trauma and burn patients as both a prognostic and a diagnostic marker, aiding in the identification of infection in patients with extensive underlying inflammation. PMID:27355024

  15. Diagnostic reasoning: where we've been, where we're going.

    PubMed

    Monteiro, Sandra M; Norman, Geoffrey

    2013-01-01

    Recently, clinical diagnostic reasoning has been characterized by "dual processing" models, which postulate a fast, unconscious (System 1) component and a slow, logical, analytical (System 2) component. However, there are a number of variants of this basic model, which may lead to conflicting claims. This paper critically reviews current theories and evidence about the nature of clinical diagnostic reasoning. We begin by briefly discussing the history of research in clinical reasoning. We then focus more specifically on the evidence to support dual-processing models. We conclude by identifying knowledge gaps about clinical reasoning and provide suggestions for future research. In contrast to work on analytical and nonanalytical knowledge as a basis for reasoning, these theories focus on the thinking process, not the nature of the knowledge retrieved. Ironically, this appears to be a revival of an outdated concept. Rather than defining diagnostic performance by problem-solving skills, it is now being defined by processing strategy. The version of dual processing that has received most attention in the literature in medical diagnosis might be labeled a "default/interventionist" model,(17) which suggests that a default system of cognitive processes (System 1) is responsible for cognitive biases that lead to diagnostic errors and that System 2 intervenes to correct these errors. Consequently, from this model, the best strategy for reducing errors is to make students aware of the biases and to encourage them to rely more on System 2. However, an accumulation of evidence suggests that (a) strategies directed at increasing analytical (System 2) processing, by slowing down, reducing distractions, paying conscious attention, and (b) strategies directed at making students aware of the effect of cognitive biases, have no impact on error rates. Conversely, strategies based on increasing application of relevant knowledge appear to have some success and are consistent with basic research on concept formation.

  16. Measurements from a Compact Cost-Effective Beamline for the THC14 PET Cyclotron

    NASA Astrophysics Data System (ADS)

    Dehnel, M. P.; Theroux, J.; Christensen, T.; Stewart, T. M.; Roeder, M.; Sirot, P.; Fasse, D.; Brasile, J. P.; Raoult, F.; Buckley, K.

    2009-03-01

    The THC14 PET Cyclotron produced by THALES specifies two compact cost-effective beamlines for high current PET radioisotope production. The design and development of the beamline system was reported previously in NIM B 261 (2007) pp 809-812. This paper describes the successful testing of this compact beamline at the first installation. A series of measurement data are presented starting from low current scintillator image data, higher current beam diagnostic data (baffles, collimators, targets) and finally a simultaneous dual beam run on Faraday Cups. The beamline system has proven to be a flexible and valuable tool for optimizing high current beam intensity distribution on target in a well-instrumented manner. This ability to tailor the beam characteristics for the target is particularly important as high power targets are developed which can handle very high beam currents.

  17. The Roles and Developments needed for Diagnostics in the ITER Fusion Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walsh, Michael

    2015-07-01

    Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasmamore » current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)« less

  18. Automated turbulence forecasts for aviation hazards

    NASA Astrophysics Data System (ADS)

    Sharman, R.; Frehlich, R.; Vandenberghe, F.

    2010-09-01

    An operational turbulence forecast system for commercial and aviation use is described that is based on an ensemble of turbulence diagnostics derived from standard NWP model outputs. In the U. S. this forecast product is named GTG (Graphical Turbulence Guidance) and has been described in detail in Sharman et al., WAF 2006. Since turbulence has many sources in the atmosphere, the ensemble approach of combining diagnostics has been shown to provide greater statistical accuracy than the use of a single diagnostic, or of a subgrid tke parameterization. GTG is sponsored by the FAA, and has undergone rigorous accuracy, safety, and usability evaluations. The GTG product is now hosted on NOAA's Aviation Data Service (ADDS), web site (http://aviationweather.gov/), for access by pilots, air traffic controllers, and dispatchers. During this talk the various turbulence diagnostics, their statistical properties, and their relative performance (based on comparisons to observations) will be presented. Importantly, the model output is ɛ1/3 (where ɛ is the eddy dissipation rate), so is aircraft independent. The diagnostics are individually and collectively calibrated so that their PDFs satisfy the expected log normal distribution of ɛ^1/3. Some of the diagnostics try to take into account the role of gravity waves and inertia-gravity waves in the turbulence generation process. Although the current GTG product is based on the RUC forecast model running over the CONUS, it is transitioning to a WRF based product, and in fact WRF-based versions are currently running operationally over Taiwan and has also been implemented for use by the French Navy in climatological studies. Yet another version has been developed which uses GFS model output to provide global turbulence forecasts. Thus the forecast product is available as a postprocessing program for WRF or other model output and provides 3D maps of turbulence likelihood of any region where NWP model data is available. Although the current GTG has been used mainly for large commercial aircraft, since the output is aircraft independent it could readily be scaled to smaller aircraft such as UAVs. Further, the ensemble technique allows the diagnostics to be used to form probabilistic forecasts, in a manner similar to ensemble NWP forecasts.

  19. Climate Model Diagnostic Analyzer

    NASA Technical Reports Server (NTRS)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  20. Advanced power system protection and incipient fault detection and protection of spaceborne power systems

    NASA Technical Reports Server (NTRS)

    Russell, B. Don

    1989-01-01

    This research concentrated on the application of advanced signal processing, expert system, and digital technologies for the detection and control of low grade, incipient faults on spaceborne power systems. The researchers have considerable experience in the application of advanced digital technologies and the protection of terrestrial power systems. This experience was used in the current contracts to develop new approaches for protecting the electrical distribution system in spaceborne applications. The project was divided into three distinct areas: (1) investigate the applicability of fault detection algorithms developed for terrestrial power systems to the detection of faults in spaceborne systems; (2) investigate the digital hardware and architectures required to monitor and control spaceborne power systems with full capability to implement new detection and diagnostic algorithms; and (3) develop a real-time expert operating system for implementing diagnostic and protection algorithms. Significant progress has been made in each of the above areas. Several terrestrial fault detection algorithms were modified to better adapt to spaceborne power system environments. Several digital architectures were developed and evaluated in light of the fault detection algorithms.

  1. Fast tomographic methods for the tokamak ISTTOK

    NASA Astrophysics Data System (ADS)

    Carvalho, P. J.; Thomsen, H.; Gori, S.; Toussaint, U. v.; Weller, A.; Coelho, R.; Neto, A.; Pereira, T.; Silva, C.; Fernandes, H.

    2008-04-01

    The achievement of long duration, alternating current discharges on the tokamak IST-TOK requires a real-time plasma position control system. The plasma position determination based on magnetic probes system has been found to be inadequate during the current inversion due to the reduced plasma current. A tomography diagnostic has been therefore installed to supply the required feedback to the control system. Several tomographic methods are available for soft X-ray or bolo-metric tomography, among which the Cormack and Neural networks methods stand out due to their inherent speed of up to 1000 reconstructions per second, with currently available technology. This paper discusses the application of these algorithms on fusion devices while comparing performance and reliability of the results. It has been found that although the Cormack based inversion proved to be faster, the neural networks reconstruction has fewer artifacts and is more accurate.

  2. Electrical signature analysis to quantify human and animal performance on fitness and therapy equipment such as a treadmill

    DOEpatents

    Cox, Daryl F.; Hochanadel, Charles D.; Haynes, Howard D.

    2010-05-18

    The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

  3. Photolithography diagnostic expert systems: a systematic approach to problem solving in a wafer fabrication facility

    NASA Astrophysics Data System (ADS)

    Weatherwax Scott, Caroline; Tsareff, Christopher R.

    1990-06-01

    One of the main goals of process engineering in the semiconductor industry is to improve wafer fabrication productivity and throughput. Engineers must work continuously toward this goal in addition to performing sustaining and development tasks. To accomplish these objectives, managers must make efficient use of engineering resources. One of the tools being used to improve efficiency is the diagnostic expert system. Expert systems are knowledge based computer programs designed to lead the user through the analysis and solution of a problem. Several photolithography diagnostic expert systems have been implemented at the Hughes Technology Center to provide a systematic approach to process problem solving. This systematic approach was achieved by documenting cause and effect analyses for a wide variety of processing problems. This knowledge was organized in the form of IF-THEN rules, a common structure for knowledge representation in expert system technology. These rules form the knowledge base of the expert system which is stored in the computer. The systems also include the problem solving methodology used by the expert when addressing a problem in his area of expertise. Operators now use the expert systems to solve many process problems without engineering assistance. The systems also facilitate the collection of appropriate data to assist engineering in solving unanticipated problems. Currently, several expert systems have been implemented to cover all aspects of the photolithography process. The systems, which have been in use for over a year, include wafer surface preparation (HMDS), photoresist coat and softbake, align and expose on a wafer stepper, and develop inspection. These systems are part of a plan to implement an expert system diagnostic environment throughout the wafer fabrication facility. In this paper, the systems' construction is described, including knowledge acquisition, rule construction, knowledge refinement, testing, and evaluation. The roles played by the process engineering expert and the knowledge engineer are discussed. The features of the systems are shown, particularly the interactive quality of the consultations and the ease of system use.

  4. The Problem of Rarity: Estimation of Prevalence in Rare Disease.

    PubMed

    Auvin, Stéphane; Irwin, John; Abi-Aad, Paul; Battersby, Alysia

    2018-05-01

    From a disease's first description to its wider recognition, factors such as changes over time in diagnostic criteria, available therapies, and subsequent mortality rates may influence diagnosed prevalence of rare diseases. To propose a novel methodology for estimating the true prevalence of rare diseases using current incidence adjusted to changing diagnostic practice over time. This article focuses on rare diseases whose diagnosis may have changed over time, and raises the hypothesis that prevalence calculated from current incidence may be higher than diagnosed prevalence, which may lag behind the current disease definition and diagnostic methods. A rare epileptic encephalopathy, Dravet syndrome (DS), is explored as an illustrative example. A targeted literature review was performed for DS to identify all reported incidence, prevalence, and mortality and depict how diagnostic practice has evolved over time. A conceptual model was developed to calculate prevalence derived from current incidence figures alone (incidence-derived prevalence) or incidence adjusted with factors that cause a diagnostic drag (diagnostic awareness-adjusted prevalence). We identified sufficient publications of incidence and prevalence to test the conceptual model. For pediatric patients with DS, diagnosed prevalence in the field (as reported in current literature) matches incidence-derived prevalence, whereas for adult patients, it is overestimated by incidence-derived prevalence, but not by diagnostic awareness-adjusted prevalence. Care should be taken with current incidence-derived prevalence figures to not overstate the prevalence in rare diseases, as methodological challenges in counting small populations, coupled with advances in rare disease discovery, may cause discrepancies. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  5. First Plasma Results from the HIT-SI Spheromak

    NASA Astrophysics Data System (ADS)

    Sieck, P. E.; Hamp, W. T.; Izzo, V. A.; Jarboe, T. R.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.

    2003-10-01

    HIT-SI is the newest device in the Helicity Injected Torus (HIT) program. HIT-SI is a ``bow tie'' spheromak formed and sustained by Steady Inductive Helicity Injection (SIHI) current drive. SIHI injects helicity at a nearly constant rate with no open field lines intersecting the boundary. (T. R. Jarboe, Fusion Technology 36) (1), p. 85, 1999 HIT-SI has been designed with a bow tie geometry to achieve stable high-β (>10%) spheromak equilibria. (U. Shumlak and T. R. Jarboe, Phys. Plasmas 7) (7), p. 2959, 2000 Diagnostics currently include surface magnetic probes and flux loops, visible light imaging, H-alpha line radiation monitors, voltage measurements across insulating breaks, injector current Rogowski coils, and injector flux loops. HIT-SI is currently operating in parallel with experiments on HIT-II. At the conclusion of HIT-II operations, HIT-SI will inherit a multi-point Thomson Scattering system, a scanning two-chord FIR interferometer, and other advanced diagnostics, as well as more power supplies to extend the discharge duration. Results are presented which characterize injector operation and possible evidence for spheromak formation.

  6. Development of quantitative radioactive methodologies on paper to determine important lateral-flow immunoassay parameters.

    PubMed

    Mosley, Garrett L; Nguyen, Phuong; Wu, Benjamin M; Kamei, Daniel T

    2016-08-07

    The lateral-flow immunoassay (LFA) is a well-established diagnostic technology that has recently seen significant advancements due in part to the rapidly expanding fields of paper diagnostics and paper-fluidics. As LFA-based diagnostics become more complex, it becomes increasingly important to quantitatively determine important parameters during the design and evaluation process. However, current experimental methods for determining these parameters have certain limitations when applied to LFA systems. In this work, we describe our novel methods of combining paper and radioactive measurements to determine nanoprobe molarity, the number of antibodies per nanoprobe, and the forward and reverse rate constants for nanoprobe binding to immobilized target on the LFA test line. Using a model LFA system that detects for the presence of the protein transferrin (Tf), we demonstrate the application of our methods, which involve quantitative experimentation and mathematical modeling. We also compare the results of our rate constant experiments with traditional experiments to demonstrate how our methods more appropriately capture the influence of the LFA environment on the binding interaction. Our novel experimental approaches can therefore more efficiently guide the research process for LFA design, leading to more rapid advancement of the field of paper-based diagnostics.

  7. Extreme ultraviolet diagnostic upgrades for kink mode control on the HBT-EP tokamak

    NASA Astrophysics Data System (ADS)

    Levesque, J. P.; Brooks, J. W.; Desanto, S.; Mauel, M. E.; Navratil, G. A.; Page, J. W.; Hansen, C. J.; Delgado-Aparicio, L.

    2016-10-01

    Optical diagnostics can provide non-invasive measurements of tokamak equilibria and the internal characteristics of MHD mode activity. We present research plans and ongoing progress on upgrading extreme ultraviolet (EUV) diagnostics in the HBT-EP tokamak. Four sets of 16 poloidal views will allow tomographic reconstruction of plasma emissivity and internal kink mode structure. Emission characteristics of naturally-occurring m/n = 2/1, 3/2, and 3/1 tearing and kink modes will be compared with expectations from a synthetic diagnostic. Coupling between internal and external modes leading up to disruptions is studied. The internal plasma response to external magnetic perturbations is investigated, and compared with magnetic response measurements. Correlation between internal emissivity and external magnetic measurements provides a global picture of long-wavelength MHD instabilities. Measurements are input to HBT-EP's GPU-based feedback system, allowing active feedback for kink modes using only optical sensors and both magnetic and edge current actuators. A separate two-color, 16-chord tangential system will be installed next year to allow reconstruction of temperature profiles and their fluctuations versus time. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  8. Portable Bio/Chemosensoristic Devices: Innovative Systems for Environmental Health and Food Safety Diagnostics

    PubMed Central

    Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano

    2017-01-01

    This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an “holistic approach” that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices. PMID:28529937

  9. Portable Bio/Chemosensoristic Devices: Innovative Systems for Environmental Health and Food Safety Diagnostics.

    PubMed

    Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano

    2017-01-01

    This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an "holistic approach" that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices.

  10. Diagnostic Concordance between DSM-5 and ICD-10 Cannabis Use Disorders.

    PubMed

    Proctor, Steven L; Williams, Daniel C; Kopak, Albert M; Voluse, Andrew C; Connolly, Kevin M; Hoffmann, Norman G

    2016-07-01

    With the recent federal mandate that all U.S. health care settings transition to ICD-10 billing codes, empirical evidence is necessary to determine if the DSM-5 designations map to their respective ICD-10 diagnostic categories/billing codes. The present study examined the concordance between DSM-5 and ICD-10 cannabis use disorder diagnoses. Data were derived from routine clinical assessments of 6871 male and 801 female inmates recently admitted to a state prison system from 2000 to 2003. DSM-5 and ICD-10 diagnostic determinations were made from algorithms corresponding to the respective diagnostic formulations. Past 12-month prevalence rates of cannabis use disorders were comparable across classification systems. The vast majority of inmates with no DSM-5 diagnosis continued to have no diagnosis per the ICD-10, and a similar proportion with a DSM-5 severe diagnosis received an ICD-10 dependence diagnosis. Most of the variation in diagnostic classifications was accounted for by those with a DSM-5 moderate diagnosis in that approximately half of these cases received an ICD-10 dependence diagnosis while the remaining cases received a harmful use diagnosis. Although there appears to be a generally high level of agreement between diagnostic classification systems for those with no diagnosis or those evincing symptoms of a more severe condition, concordance between DSM-5 moderate and ICD-10 dependence diagnoses was poor. Additional research is warranted to determine the appropriateness and implications of the current DSM-5 coding guidelines regarding the assignment of an ICD-10 dependence code for those with a DSM-5 moderate diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Diagnosis - the limiting focus of taxonomy.

    PubMed

    Sturmberg, Joachim P; Martin, Carmel M

    2016-02-01

    The focus on the diagnosis is a pivotal aspect of medical practice since antiquity. Diagnostic taxonomy helped to categorize ailments to improve medical care, and in its social sense resulted in validation of the sick role for some, but marginalization or stigmatization for others. In the medical industrial complex, diagnostic taxonomy structured health care financing, management and practitioner remuneration. However, with increasing demands from multiple agencies, there are increasing unintended and unwarranted consequences of our current taxonomies and diagnostic processes resulting from the conglomeration of underpinning concepts, theories, information and motivations. We argue that the increasing focus on the diagnosis resulted in excessive compartmentalization - 'partialism' - of medical practice, diminishing medical care and being naively simplistic in light of the emerging understanding of the interconnected nature of the diseasome. The human is a complex organic system of interconnecting dynamics and feedback loops responding to internal and external forces including genetic, epigenetic and environmental attractors, rather than the sum of multiple discrete organs which can develop isolated diseases or multiple morbidities. Solutions to these unintended consequences of many contemporary health system processes involve revisiting the nature of diagnostic taxonomies and the processes of their construction. A dynamic taxonomic framework would shift to more relevant attractors at personal, clinical and health system levels recognizing the non-linear nature of health and disease. Human health at an individual, group and population level is the ability to adapt to internal and external stressors with resilience throughout the life course, yet diagnostic taxonomies are increasingly constructed around fixed anchors. Understanding diagnosis as dissecting, pigeonholing or bean counting (learning by dividing) is no longer useful, the challenge for the future is to understand the big picture (learning by connecting). Diagnostic categorization needs to embrace a meta-learning approach open to human variability. © 2014 John Wiley & Sons, Ltd.

  12. Model-based diagnostics of gas turbine engine lubrication systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byington, C.S.

    1998-09-01

    The objective of the current research was to develop improved methodology for diagnosing anomalies and maintaining oil lubrication systems for gas turbine engines. The effort focused on the development of reasoning modules that utilize the existing, inexpensive sensors and are applicable to on-line monitoring within the full-authority digital engine controller (FADEC) of the engine. The target application is the Enhanced TF-40B gas turbine engine that powers the Landing Craft Air Cushion (LCAC) platform. To accomplish the development of the requisite data fusion algorithms and automated reasoning for the diagnostic modules, Penn State ARL produced a generic Turbine Engine Lubrication Systemmore » Simulator (TELSS) and Data Fusion Workbench (DFW). TELSS is a portable simulator code that calculates lubrication system parameters based upon one-dimensional fluid flow resistance network equations. Validation of the TF- 40B modules was performed using engineering and limited test data. The simulation model was used to analyze operational data from the LCAC fleet. The TELSS, as an integral portion of the DFW, provides the capability to experiment with combinations of variables and feature vectors that characterize normal and abnormal operation of the engine lubrication system. The model-based diagnostics approach is applicable to all gas turbine engines and mechanical transmissions with similar pressure-fed lubrication systems.« less

  13. Molecular SPECT Imaging: An Overview

    PubMed Central

    Khalil, Magdy M.; Tremoleda, Jordi L.; Bayomy, Tamer B.; Gsell, Willy

    2011-01-01

    Molecular imaging has witnessed a tremendous change over the last decade. Growing interest and emphasis are placed on this specialized technology represented by developing new scanners, pharmaceutical drugs, diagnostic agents, new therapeutic regimens, and ultimately, significant improvement of patient health care. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) have their signature on paving the way to molecular diagnostics and personalized medicine. The former will be the topic of the current paper where the authors address the current position of the molecular SPECT imaging among other imaging techniques, describing strengths and weaknesses, differences between SPECT and PET, and focusing on different SPECT designs and detection systems. Radiopharmaceutical compounds of clinical as well-preclinical interest have also been reviewed. Moreover, the last section covers several application, of μSPECT imaging in many areas of disease detection and diagnosis. PMID:21603240

  14. Study report on combining diagnostic and therapeutic considerations with subsystem and whole-body simulation

    NASA Technical Reports Server (NTRS)

    Furukawa, S.

    1975-01-01

    Current applications of simulation models for clinical research described included tilt model simulation of orthostatic intolerance with hemorrhage, and modeling long term circulatory circulation. Current capabilities include: (1) simulation of analogous pathological states and effects of abnormal environmental stressors by the manipulation of system variables and changing inputs in various sequences; (2) simulation of time courses of responses of controlled variables by the altered inputs and their relationships; (3) simulation of physiological responses of treatment such as isotonic saline transfusion; (4) simulation of the effectiveness of a treatment as well as the effects of complication superimposed on an existing pathological state; and (5) comparison of the effectiveness of various treatments/countermeasures for a given pathological state. The feasibility of applying simulation models to diagnostic and therapeutic research problems is assessed.

  15. Cancer Salivary Biomarkers for Tumours Distant to the Oral Cavity

    PubMed Central

    Rapado-González, Óscar; Majem, Blanca; Muinelo-Romay, Laura; López-López, Rafa; Suarez-Cunqueiro, María Mercedes

    2016-01-01

    The analysis of saliva as a diagnostic approach for systemic diseases was proposed just two decades ago, but recently great interest in the field has emerged because of its revolutionary potential as a liquid biopsy and its usefulness as a non-invasive sampling method. Multiple molecules isolated in saliva have been proposed as cancer biomarkers for diagnosis, prognosis, drug monitoring and pharmacogenetic studies. In this review, we focus on the current status of the salivary diagnostic biomarkers for different cancers distant to the oral cavity, noting their potential use in the clinic and their applicability in personalising cancer therapies. PMID:27626410

  16. Future Issues and Approaches to Health Monitoring and Failure Prevention for Oil-Free Gas Turbines

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher

    2004-01-01

    Recent technology advances in foil air bearings, high temperature solid lubricants and computer based modeling has enabled the development of small Oil-Free gas turbines. These turbomachines are currently commercialized as small (<100 kW) microturbine generators and larger machines are being developed. Based upon these successes and the high potential payoffs offered by Oil-Free systems, NASA, industry, and other government entities are anticipating Oil-Free gas turbine propulsion systems to proliferate future markets. Since an Oil-Free engine has no oil system, traditional approaches to health monitoring and diagnostics, such as chip detection, oil analysis, and possibly vibration signature analyses (e.g., ball pass frequency) will be unavailable. As such, new approaches will need to be considered. These could include shaft orbit analyses, foil bearing temperature measurements, embedded wear sensors and start-up/coast down speed analysis. In addition, novel, as yet undeveloped techniques may emerge based upon concurrent developments in MEMS technology. This paper introduces Oil-Free technology, reviews the current state of the art and potential for future turbomachinery applications and discusses possible approaches to health monitoring, diagnostics and failure prevention.

  17. Magnetic Diagnosis Upgrade and Analysis for MHD Instabilities on the J-TEXT

    NASA Astrophysics Data System (ADS)

    Guo, Daojing; Hu, Qiming; Zhuang, Ge; Wang, Nengchao; Ding, Yonghua; Tang, Yuejin; Yu, Qingquan; Huazhong University of Science; Technology Team; Max-Planck-Institut für Plasmaphysik Collaboration

    2017-10-01

    The magnetic diagnostic system on the J-TEXT tokamak has been upgraded to measure the magnetohydrodynamic (MHD) instabilities with diverse bands of frequencies. 12 saddle loop probes and 73 Mirnov probes are newly developed. The fabrication and installment of the new probes are elaborately designed, in consideration of higher spatial resolution and better amplitude-frequency characteristic. In this case, the probes utilize two kinds of novel fabrication craft, one of which is low temperature co-fired ceramics (LTCC), the other is flexible printed circuit (FPC). A great deal of experiments on the J-TEXT have validated the stability of the new system. Some typical discharges observed by the new diagnostic system are reviewed. In order to extract useful information from raw signals, several efficient signal processing methods are reviewed. An analytical model based on lumped eddy current circuits is used to compensate equilibrium flux and the corresponding eddy current fluxes, a visualization processing based on singular value decomposition (SVD) and cross-power spectrum are applied to detect the mode number. Fusion Science Program of China (Contract Nos. 2015GB111001 and 2014GB108000) and the National Natural Science Foundation of China (Contract Nos. 11505069 and 11405068).

  18. Contributions from personality- and psychodynamically oriented assessment to the development of the DSM-5 personality disorders.

    PubMed

    Huprich, Steven K

    2011-07-01

    Advances in personality assessment over the past 20 years have notably influenced the proposed assessment and classification of personality disorders in the Diagnostic and Statistical Manual of Mental Disorders (5th ed. [DSM-5]). However, a considerable body of personality assessment and psychodynamically oriented assessment research has significant relevance to the way in which personality disorders are evaluated that appears to have gone unrecognized in the current proposals for DSM-5. In this article, I discuss the ways in which some of these 2 bodies of literature can and should inform the DSM-5 so that the diagnostic nomenclature can be more scientifically and comprehensively informed and consequently improve the clinical utility of a diagnostic system in need of considerable revision.

  19. Quality systems in veterinary diagnostics laboratories.

    PubMed

    de Branco, Freitas Maia L M

    2007-01-01

    Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.

  20. The Development of a Fiber Optic Raman Temperature Measurement System for Rocket Flows

    NASA Technical Reports Server (NTRS)

    Degroot, Wim A.

    1992-01-01

    A fiberoptic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurement of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing testing. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentrations by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental program is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rocket.

  1. Disorders Related to Use of Psychoactive Substances in DSM-5: Changes and Challenges.

    PubMed

    Bhad, Roshan; Lal, Rakesh; Balhara, Yatan Pal Singh

    2015-01-01

    In the most recent edition of Diagnostic and Statistical Manual (DSM) that is DSM-5 many modifications have been made in substance use disorder section. These include changes in terminology; sections and categories; diagnostic criteria; threshold for diagnosis; severity; and specifier. Additionally, there have been certain additions and omissions from the earlier version. Critical evaluation of the changes made to the section on disorders related to use of psychoactive substances in India context has not been published so far. The current paper presents a critique of the changes made to the substance use disorder section in DSM-5. The rationale for these changes put forth by DSM-5 work group on substance related disorders have been discussed. Additionally, attempt has been made to highlight the possible future challenges consequent to the current nosological revision for substance use disorder category. Overall DSM-5 seems to be promising in fulfilling its goal of DSM-ICD harmonisation and movement towards an internationally compatible and practical diagnostic system for mental health disorders. It has increased the scope of addiction by inclusion of behavioural addiction. It has also tried to balance the categorical and dimensional approach to diagnosis. However, the real test of this newer edition of one of the most commonly used nosological systems will be during clinical care and research. This will help address the debatable issues regarding the changes that DSM-5 brings with it.

  2. Evaluation of Human Research Facility Ultrasound With the ISS Video System

    NASA Technical Reports Server (NTRS)

    Melton, Shannon; Sargsyan, Ashot

    2003-01-01

    Most medical equipment on the International Space Station (ISS) is manifested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical situations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-operator during an exam to facilitate the diagnosis in a timely fashion. In this document, we strove to verify that the HRF ultrasound video output is compatible with the ISS video system, identify ISS video system field rates and resolutions that are acceptable for varying clinical scenaiios, and evaluate the HRF ultrasound video with a commercial, off-the-shelf video converter, and compare it with the ISS video system.

  3. Propulsion Control Technology Development in the United States A Historical Perspective

    NASA Technical Reports Server (NTRS)

    Jaw, Link C.a; Garg, Sanjay

    2005-01-01

    This paper presents a historical perspective of the advancement of control technologies for aircraft gas turbine engines. The paper primarily covers technology advances in the United States in the last 60 years (1940 to approximately 2002). The paper emphasizes the pioneering technologies that have been tested or implemented during this period, assimilating knowledge and experience from industry experts, including personal interviews with both current and retired experts. Since the first United States-built aircraft gas turbine engine was flown in 1942, engine control technology has evolved from a simple hydro-mechanical fuel metering valve to a full-authority digital electronic control system (FADEC) that is common to all modern aircraft propulsion systems. At the same time, control systems have provided engine diagnostic functions. Engine diagnostic capabilities have also evolved from pilot observation of engine gauges to the automated on-board diagnostic system that uses mathematical models to assess engine health and assist in post-flight troubleshooting and maintenance. Using system complexity and capability as a measure, we can break the historical development of control systems down to four phases: (1) the start-up phase (1942 to 1949), (2) the growth phase (1950 to 1969), (3) the electronic phase (1970 to 1989), and (4) the integration phase (1990 to 2002). In each phase, the state-of-the-art control technology is described and the engines that have become historical landmarks, from the control and diagnostic standpoint, are identified. Finally, a historical perspective of engine controls in the last 60 years is presented in terms of control system complexity, number of sensors, number of lines of software (or embedded code), and other factors.

  4. Secular Trends in Pupils' Assessments of Physical Education Lessons in Regard to Their Self-Perception of Physical Fitness across the Educational Systems of Czech Republic and Poland

    ERIC Educational Resources Information Center

    Frömel, Karel; Vašícková, Jana; Svozil, Zbynek; Chmelík, František; Skalik, Krzysztof; Groffik, Dorota

    2014-01-01

    Observation of trends in physical education plays an integral role in motor-development diagnostics and in encouraging physical activity and a healthy lifestyle. This study aims to elucidate the current state of and trends in pupils' assessments of physical education lessons (PELs) in different education systems in the context of self-perception…

  5. Molecular Pathology and Personalized Medicine: The Dawn of a New Era in Companion Diagnostics-Practical Considerations about Companion Diagnostics for Non-Small-Cell-Lung-Cancer.

    PubMed

    Plönes, Till; Engel-Riedel, Walburga; Stoelben, Erich; Limmroth, Christina; Schildgen, Oliver; Schildgen, Verena

    2016-01-15

    Companion diagnostics (CDx) have become a major tool in molecular pathology and assist in therapy decisions in an increasing number of various cancers. Particularly, the developments in lung cancer have been most impressing in the last decade and consequently lung cancer mutation testing and molecular profiling has become a major business of diagnostic laboratories. However, it has become difficult to decide which biomarkers are currently relevant for therapy decisions, as many of the new biomarkers are not yet approved as therapy targets, remain in the status of clinical studies, or still have not left the experimental phase. The current review is focussed on those markers that do have current therapy implications, practical implications arising from the respective companion diagnostics, and thus is focused on daily practice.

  6. Overview of MDX-A System for Medical Diagnosis

    PubMed Central

    Mittal, S.; Chandrasekaran, B.; Smith, J.

    1979-01-01

    We describe the design and performance of MDX, an experimental medical diagnosis system, which currently diagnoses in the syndrome called Cholestasis. The needed medical knowledge is represented in a scheme called conceptual structures, which can be viewed as a collection of conceptual experts interacting according to certain well-defined principles. MDX has three components: the diagnostic system, a patient data base and a radiology consultant. We describe these components, the inter-expert communication system and the query language used by these components. The system is illustrated by means of its performance on a real case.

  7. Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission

    DOE PAGES

    Chrystal, Colin; Burrell, Keith H.; Grierson, Brian A.; ...

    2015-10-20

    Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in-situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination diagnostic (CER) at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain informationmore » about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. Lastly, the methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.« less

  8. Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission

    NASA Astrophysics Data System (ADS)

    Chrystal, C.; Burrell, K. H.; Grierson, B. A.; Pace, D. C.

    2015-10-01

    Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.

  9. Diagnostic Crossover in Anorexia Nervosa and Bulimia Nervosa: Implications for DSM-V

    PubMed Central

    Eddy, Kamryn T.; Dorer, David J.; Franko, Debra L.; Tahilani, Kavita; Thompson-Brenner, Heather; Herzog, David B.

    2011-01-01

    Objective The Diagnostic and Statistical Manual of Mental Disorders (DSM) is designed primarily as a clinical tool. Yet high rates of diagnostic “crossover” among the anorexia nervosa subtypes and bulimia nervosa may reflect problems with the validity of the current diagnostic schema, thereby limiting its clinical utility. This study was designed to examine diagnostic crossover longitudinally in anorexia nervosa and bulimia nervosa to inform the validity of the DSM-IV-TR eating disorders classification system. Method A total of 216 women with a diagnosis of anorexia nervosa or bulimia nervosa were followed for 7 years; weekly eating disorder symptom data collected using the Eating Disorder Longitudinal Interval Follow-Up Examination allowed for diagnoses to be made throughout the follow-up period. Results Over 7 years, the majority of women with anorexia nervosa experienced diagnostic crossover: more than half crossed between the restricting and binge eating/purging anorexia nervosa subtypes over time; one-third crossed over to bulimia nervosa but were likely to relapse into anorexia nervosa. Women with bulimia nervosa were unlikely to cross over to anorexia nervosa. Conclusions These findings support the longitudinal distinction of anorexia nervosa and bulimia nervosa but do not support the anorexia nervosa subtyping schema. PMID:18198267

  10. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    NASA Astrophysics Data System (ADS)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  11. Design and development of a fiber optic TDI CCD-based slot-scan digital mammography system

    NASA Astrophysics Data System (ADS)

    Toker, Emre; Piccaro, Michele F.

    1993-12-01

    We previously reported on the development, design, and clinical evaluation of a CCD-based, high performance, filmless imaging system for stereotactic needle biopsy procedures in mammography. The MammoVision system has a limited imaging area of 50 mm X 50 mm, since it is designed specifically for breast biopsy applications. We are currently developing a new filmless imaging system designed to cover the 18 cm X 24 cm imaging area required for screening and diagnostic mammography. The diagnostic mammography system is based on four 1100 X 330 pixel format, full-frame, scientific grade, front illuminated, MPP mode CCDs, with 24 micrometers X 24 micrometers square pixels Each CCD is coupled to an x-ray intensifying screen via a 1.7:1 fiber optic reducer. The detector assembly (180 mm long and 13.5 mm wide) is scanned across the patient's breast synchronously with the x-ray source, with the CCDs operated in time-delay integration (TDI) mode. The total scan time is 4.0 seconds.

  12. An initial exploration for comprehensive assessment of IgG4-related lung disease: analyses on the cases enrolled from a systematic review.

    PubMed

    Wang, An; Fan, Jie; Chen, Xiaofeng; Wang, Shaohua

    2018-03-01

    The existence of two diagnostic systems, the Boston and Japan criteria, for immunoglobulin G4-related disease (IgG4-RD) confuse the medical practice. We aimed to develop a comprehensive assessment based on the weight of each diagnostic item in the existing criteria to improve the diagnostic efficiency of Boston criteria. We assessed the patients enrolled by a systematic review of the literatures using the Boston criteria, Japan criteria and a tentative comprehensive assessment respectively, and evaluated the efficiency of each system and their consistency. Our analysis showed that the distinction in pathological diagnostic items was similar for the Boston criteria (IgG4+/IgG+ ratio, P<0.01; the number of pathological features and IgG4+ count, P<0.001) and comprehensive assessment (IgG4+/IgG+ ratio and the number of pathological features, P<0.001; IgG4+ count, P<0.05). For the Japan criteria, a good distinction in the number of pathological features was demonstrated (P<0.05) but the difference in the IgG4+/IgG+ ratio and IgG4+ count was not significant. There was relatively poor consistency between the Boston and Japan criteria (Kappa =0.482, P<0.001), while there was good agreement (Kappa =0.811, P<0.001), but a significant difference (P=0.011, McNemar matching test), between the Boston criteria and comprehensive assessment. The current two diagnostic systems have poor consistency. Comprehensive assessment has good agreement with the Boston criteria, but can identify those cases in Boston Category 3 who could still be diagnosed as IgG4-related lung disease. Considering the weight of diagnostic items, the scoring system is a tentative exploration that should be improved with further experience in diagnosing IgG4-related lung disease.

  13. Development of a real time monitor and multivariate method for long term diagnostics of atmospheric pressure dielectric barrier discharges: application to He, He/N2, and He/O2 discharges.

    PubMed

    O'Connor, N; Milosavljević, V; Daniels, S

    2011-08-01

    In this paper we present the development and application of a real time atmospheric pressure discharge monitoring diagnostic. The software based diagnostic is designed to extract latent electrical and optical information associated with the operation of an atmospheric pressure dielectric barrier discharge (APDBD) over long time scales. Given that little is known about long term temporal effects in such discharges, the diagnostic methodology is applied to the monitoring of an APDBD in helium and helium with both 0.1% nitrogen and 0.1% oxygen gas admixtures over periods of tens of minutes. Given the large datasets associated with the experiments, it is shown that this process is much expedited through the novel application of multivariate correlations between the electrical and optical parameters of the corresponding chemistries which, in turn, facilitates comparisons between each individual chemistry also. The results of these studies show that the electrical and optical parameters of the discharge in helium and upon the addition of gas admixtures evolve over time scales far longer than the gas residence time and have been compared to current modelling works. It is envisaged that the diagnostic together with the application of multivariate correlations will be applied to rapid system identification and prototyping in both experimental and industrial APDBD systems in the future.

  14. The dimensionality of alcohol use disorders and alcohol consumption in a cross-national perspective

    PubMed Central

    Borges, Guilherme; Ye, Yu; Bond, Jason; Cherpitel, Cheryl J.; Cremonte, Mariana; Moskalewicz, Jacek; Swiatkiewicz, Grazyna; Rubio-Stipec, Maritza

    2009-01-01

    Aims To replicate the finding that there is a single dimension trait in alcohol use disorders and to test whether usual 5+ drinks for men and/4+ drinks for women and other measures of alcohol consumption help to improve alcohol use disorder criteria in a series of diverse patients from Emergency Departments (EDs) in four countries. Design Cross-sectional surveys of patient 18 and older that reflected consecutive arrival at the ED. The Composite International Diagnostic Interview Core was used to obtain a diagnosis of DSM-IV alcohol dependence and alcohol abuse. Quantity and frequency of drinking and drunkenness as well as usual number of drinks consumed during the last year. Setting Participants were 5,195 injured and non-injured patients attending 7 EDs in 4 countries, Argentina, Mexico, Poland the U.S., (between 1995-2001). Findings Using exploratory factor analyses alcohol use disorders can be described as a single, unidimensional continuum without any clear cut distinction between the criterions for dependence and abuse in all sites. Results from item response theory analyses showed that the current DSM-IV criterions tap people in the middle-upper end of the alcohol use disorder continuum. Alcohol consumption (amount and frequency of use) can be used in all EDs with the current DSM-IV diagnostic criterions to help tap the middle-lower part of this continuum. Even though some specific diagnostic criterions and some alcohol consumption variables showed differential item function across sites, test response curves were invariant for ED sites and their inclusion would not impact the final (total) performance of the diagnostic system. Conclusions DSM-IV abuse and dependence form a unidimensional continuum in ED patients regardless of country of survey. Alcohol consumption variables, if added, would help to tap patients with more moderate severity. DSM diagnostic system for alcohol use disorders showed invariance and performed extremely well in these samples. PMID:20078482

  15. Autoimmune diagnostics: the technology, the strategy and the clinical governance.

    PubMed

    Bizzaro, Nicola; Tozzoli, Renato; Villalta, Danilo

    2015-02-01

    In recent years, there has been a profound change in autoimmune diagnostics. From long, tiring and inaccurate manual methods, the art of diagnostics has turned to modern, rapid and automated technology. New antibody tests have been developed, and almost all autoimmune diseases now have some specific diagnostic markers. The current need to make the most of available economic and human resources has led to the production of diagnostic algorithms and guidelines designated for optimal strategic use of the tests and to increase the diagnostic appropriateness. An important role in this scenario was assumed by the laboratory autoimmunologist, whose task is not only to govern the analytical phase, but also to help clinicians in correctly choosing the most suitable test for each clinical situation and provide consultancy support. In this review, we summarize recent advances in technology, describe the diagnostic strategies and highlight the current role of the laboratory autoimmunologist in the clinical governance of autoimmune diagnostics.

  16. A design and implementation methodology for diagnostic systems

    NASA Technical Reports Server (NTRS)

    Williams, Linda J. F.

    1988-01-01

    A methodology for design and implementation of diagnostic systems is presented. Also discussed are the advantages of embedding a diagnostic system in a host system environment. The methodology utilizes an architecture for diagnostic system development that is hierarchical and makes use of object-oriented representation techniques. Additionally, qualitative models are used to describe the host system components and their behavior. The methodology architecture includes a diagnostic engine that utilizes a combination of heuristic knowledge to control the sequence of diagnostic reasoning. The methodology provides an integrated approach to development of diagnostic system requirements that is more rigorous than standard systems engineering techniques. The advantages of using this methodology during various life cycle phases of the host systems (e.g., National Aerospace Plane (NASP)) include: the capability to analyze diagnostic instrumentation requirements during the host system design phase, a ready software architecture for implementation of diagnostics in the host system, and the opportunity to analyze instrumentation for failure coverage in safety critical host system operations.

  17. Realtime Knowledge Management (RKM): From an International Space Station (ISS) Point of View

    NASA Technical Reports Server (NTRS)

    Robinson, Peter I.; McDermott, William; Alena, Richard L.

    2004-01-01

    We are developing automated methods to provide realtime access to spacecraft domain knowledge relevant a spacecraft's current operational state. The method is based upon analyzing state-transition signatures in the telemetry stream. A key insight is that documentation relevant to a specific failure mode or operational state is related to the structure and function of spacecraft systems. This means that diagnostic dependency and state models can provide a roadmap for effective documentation navigation and presentation. Diagnostic models consume the telemetry and derive a high-level state description of the spacecraft. Each potential spacecraft state description is matched against the predictions of models that were developed from information found in the pages and sections in the relevant International Space Station (ISS) documentation and reference materials. By annotating each model fragment with the domain knowledge sources from which it was derived we can develop a system that automatically selects those documents representing the domain knowledge encapsulated by the models that compute the current spacecraft state. In this manner, when the spacecraft state changes, the relevant documentation context and presentation will also change.

  18. A General Architecture for Intelligent Tutoring of Diagnostic Classification Problem Solving

    PubMed Central

    Crowley, Rebecca S.; Medvedeva, Olga

    2003-01-01

    We report on a general architecture for creating knowledge-based medical training systems to teach diagnostic classification problem solving. The approach is informed by our previous work describing the development of expertise in classification problem solving in Pathology. The architecture envelops the traditional Intelligent Tutoring System design within the Unified Problem-solving Method description Language (UPML) architecture, supporting component modularity and reuse. Based on the domain ontology, domain task ontology and case data, the abstract problem-solving methods of the expert model create a dynamic solution graph. Student interaction with the solution graph is filtered through an instructional layer, which is created by a second set of abstract problem-solving methods and pedagogic ontologies, in response to the current state of the student model. We outline the advantages and limitations of this general approach, and describe it’s implementation in SlideTutor–a developing Intelligent Tutoring System in Dermatopathology. PMID:14728159

  19. Simulation of Clinical Diagnosis: A Comparative Study

    PubMed Central

    de Dombal, F. T.; Horrocks, Jane C.; Staniland, J. R.; Gill, P. W.

    1971-01-01

    This paper presents a comparison between three different modes of simulation of the diagnostic process—a computer-based system, a verbal mode, and a further mode in which cards were selected from a large board. A total of 34 subjects worked through a series of 444 diagnostic simulations. The verbal mode was found to be most enjoyable and realistic. At the board, considerable amounts of extra irrelevant data were selected. At the computer, the users asked the same questions every time, whether or not they were relevant to the particular diagnosis. They also found the teletype distracting, noisy, and slow. The need for an acceptable simulation system remains, and at present our Minisim and verbal modes are proving useful in training junior clinical students. Future simulators should be flexible, economical, and acceptably realistic—and to us this latter criterion implies the two-way use of speech. We are currently developing and testing such a system. PMID:5579197

  20. Electron density measurements in STPX plasmas

    NASA Astrophysics Data System (ADS)

    Clark, Jerry; Williams, R.; Titus, J. B.; Mezonlin, E. D.; Akpovo, C.; Thomas, E.

    2017-10-01

    Diagnostics have been installed to measure the electron density of Spheromak Turbulent Physics Experiment (STPX) plasmas at Florida A. & M. University. An insertable probe, provided by Auburn University, consisting of a combination of a triple-tipped Langmuir probe and a radial array consisting of three ion saturation current / floating potential rings has been installed to measure instantaneous plasma density, temperature and plasma potential. As the ramp-up of the experimental program commences, initial electron density measurements from the triple-probe show that the electron density is on the order of 1019 particles/m3. For a passive measurement, a CO2 interferometer system has been designed and installed for measuring line-averaged densities and to corroborate the Langmuir measurements. We describe the design, calibration, and performance of these diagnostic systems on large volume STPX plasmas.

  1. Beam transport and monitoring for laser plasma accelerators

    NASA Astrophysics Data System (ADS)

    Nakamura, K.; Sokollik, T.; van Tilborg, J.; Gonsalves, A. J.; Shaw, B.; Shiraishi, S.; Mittal, R.; De Santis, S.; Byrd, J. M.; Leemans, W.

    2012-12-01

    The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

  2. Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bigio, I.J.; Loree, T.R.; Mourant, J.

    1993-08-01

    A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact thatmore » many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength dependence of elastic scattering. The data acquisition and storage/display time with the OBS instrument is {approximately}1 second. Thus, in addition to the reduced invasiveness of this technique compared with current state-of-the-art methods (surgical biopsy and pathology analysis), the OBS offers the possibility of impressively faster diagnostic assessment. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope, catheter or hypodermic, or to direct surface examination (e.g. as in skin cancer or cervical cancer). It has been tested in vitro on animal and human tissue samples, and clinical testing in vivo is currently in progress.« less

  3. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  4. Thomson scattering diagnostic on the Compact Toroidal Hybrid Experiment

    NASA Astrophysics Data System (ADS)

    Traverso, Peter; Maurer, D. A.; Ennis, D. A.; Hartwell, G. J.

    2016-10-01

    A Thomson scattering system is being commissioned for the non-axisymmetric plasmas of the Compact Toroidal Hybrid (CTH), a five-field period current-carrying torsatron. The system takes a single point measurement at the magnetic axis to both calibrate the two- color soft x-ray Te system and serve as an additional diagnostic for the V3FIT 3D equilibrium reconstruction code. A single point measurement will reduce the uncertainty in the reconstructed peak pressure by an order of magnitude for both current-carrying plasmas and future gyrotron-heated stellarator plasmas. The beam, generated by a frequency doubled Continuum 2 J, Nd:YaG laser, is passed vertically through an entrance Brewster window and a two-aperture optical baffle system to minimize stray light. The beam line propagates 8 m to the CTH device mid-plane with the beam diameter < 3 mm inside the plasma volume. Thomson scattered light is collected by two adjacent f/2 plano-convex condenser lenses and focused onto a custom fiber bundle. The fiber is then re-bundled and routed to a Holospec f/1.8 spectrograph to collect the red-shifted scattered light from 535-565 nm. The system has been designed to measure plasmas with core Te of 100 to 200 eV and densities of 5 ×1018 to 5 ×1019 m-3. Work supported by USDOE Grant DE-FG02-00ER54610.

  5. Thomson scattering diagnostic on the Compact Toroidal Hybrid Experiment

    NASA Astrophysics Data System (ADS)

    Traverso, P. J.; Ennis, D. A.; Hartwell, G. J.; Kring, J. D.; Maurer, D. A.

    2017-10-01

    A Thomson scattering system is being commissioned for the non-axisymmetric plasmas of the Compact Toroidal Hybrid (CTH), a five-field period current-carrying torsatron. The system takes a single point measurement at the magnetic axis to both calibrate the two-color soft x-ray Te system and serve as an additional diagnostic for the V3FIT 3D equilibrium reconstruction code. A single point measurement will reduce the uncertainty in the reconstructed peak pressure by an order of magnitude for both current-carrying plasmas and future gyrotron-heated stellarator plasmas. The beam, generated by a frequency doubled Continuum 2 J, Nd:YAG laser, is passed vertically through an entrance Brewster window and a two-aperture optical baffle system to minimize stray light. Thomson scattered light is collected by two adjacent f/2 plano-convex condenser lenses and routed via a fiber bundle through a Holospec f/1.8 spectrograph. The red-shifted scattered light from 533-563 nm will be collected by an array of Hamamatsu H11706-40 PMTs. The system has been designed to measure plasmas with core Te of 100 to 200 eV and densities of 5 ×1018 to 5 ×1019 m-3. Stray light and calibration data for a single wavelength channel will be presented. This work is supported by U.S. Department of Energy Grant No. DE-FG02-00ER54610.

  6. Performance of the Delirium Rating Scale-Revised-98 Against Different Delirium Diagnostic Criteria in a Population With a High Prevalence of Dementia.

    PubMed

    Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Viñuelas, Eva; Palma, José; Ferré, Gisela; Grau, Imma; Vilella, Elisabet

    2015-01-01

    Delirium diagnosis in elderly is often complicated by underlying dementia. We evaluated performance of the Delirium Rating Scale-Revised-98 (DRS-R98) in patients with high dementia prevalence and also assessed concordance among past and current diagnostic criteria for delirium. Cross-sectional analysis of newly admitted patients to a skilled nursing facility over 6 months, who were rated within 24-48 hours after admission. Interview for Diagnostic and Statistical Manual of Mental Disorders, 3rd edition-R (DSM)-III-R, DSM-IV, DSM-5, and International Classification of Diseases 10th edition delirium ratings, administration of the DRS-R98, and assessment of dementia using the Informant Questionnaire on Cognitive Decline in the Elderly were independently performed by 3 researchers. Discriminant analyses (receiver operating characteristics curves) were used to study DRS-R98 accuracy against different diagnostic criteria. Hanley and McNeil test compared the area under the curve for DRS-R98's discriminant performance for all diagnostic criteria. Dementia was present in 85/125 (68.0%) subjects, and 36/125 (28.8%) met criteria for delirium by at least 1 classification system, whereas only 19/36 (52.8%) did by all. DSM-III-R diagnosed the most as delirious (27.2%), followed by DSM-5 (24.8%), DSM-IV-TR (22.4%), and International Classification of Diseases 10th edition (16%). DRS-R98 had the highest AUC when discriminating DSM-III-R delirium (92.9%), followed by DSM-IV (92.4%), DSM-5 (91%), and International Classification of Diseases 10th edition (90.5%), without statistical differences among them. The best DRS-R98 cutoff score was ≥14.5 for all diagnostic systems except International Classification of Diseases 10th edition (≥15.5). There is a low concordance across diagnostic systems for identification of delirium. The DRS-R98 performs well despite differences across classification systems perhaps because it broadly assesses phenomenology, even in this population with a high prevalence of dementia. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  7. Numerical Simulations of Thick Aluminum Wire Behavior Under Megampere Current Drive

    DTIC Science & Technology

    2009-06-01

    time dependences of the wire radii agree rather well with the experimental results obtained using laser diagnostics and light imaging. The...simulated time dependences of the wire radii agree rather well with the experimental results obtained using laser diagnostics and light imaging. The...experiments involved a wide range of diagnostics , including current probes, streaked imaging of optical emission, 4-frame laser shadowgraphy, fast

  8. Comparing Symptoms of Autism Spectrum Disorders Using the Current "DSM-IV-TR" Diagnostic Criteria and the Proposed "DSM-V" Diagnostic Criteria

    ERIC Educational Resources Information Center

    Worley, Julie A.; Matson, Johnny L.

    2012-01-01

    The American Psychiatric Association has proposed major revisions for the diagnostic category encompassing Autism Spectrum Disorders (ASD), which will reportedly increase the specificity and maintain the sensitivity of diagnoses. As a result, the aim of the current study was to compare symptoms of ASD in children and adolescents (N = 208) who met…

  9. Automated pinhole-aperture diagnostic for the current profiling of TWT electron beams

    NASA Astrophysics Data System (ADS)

    Wei, Yu-Xiang; Huang, Ming-Guang; Liu, Shu-Qing; Liu, Jin-Yue; Hao, Bao-Liang; Du, Chao-Hai; Liu, Pu-Kun

    2013-02-01

    The measurement system reported here is intended for use in determining the current density distribution of electron beams from Pierce guns for use in TWTs. The system was designed to automatically scan the cross section of the electron beam and collect the high-resolution data with a Faraday cup probe mounted on a multistage manipulator using the LabVIEW program. A 0.06 mm thick molybdenum plate with a pinhole and a Faraday cup mounted as a probe assembly was employed to sample the electron beam current with 0.5 µm space resolution. The thermal analysis of the probe with pulse beam heating was discussed. A 0.45 µP electron gun with the expected minimum beam radius 0.42 mm was measured and the three-dimensional current density distribution, beam envelope and phase space were presented.

  10. A domain analysis approach to clear-air turbulence forecasting using high-density in-situ measurements

    NASA Astrophysics Data System (ADS)

    Abernethy, Jennifer A.

    Pilots' ability to avoid clear-air turbulence (CAT) during flight affects the safety of the millions of people who fly commercial airlines and other aircraft, and turbulence costs millions in injuries and aircraft maintenance every year. Forecasting CAT is not straightforward, however; microscale features like the turbulence eddies that affect aircraft (100m) are below the current resolution of operational numerical weather prediction (NWP) models, and the only evidence of CAT episodes, until recently, has been sparse, subjective reports from pilots known as PIREPs. To forecast CAT, researchers use a simple weighted sum of top-performing turbulence indicators derived from NWP model outputs---termed diagnostics---based on their agreement with current PIREPs. However, a new, quantitative source of observation data---high-density measurements made by sensor equipment and software on aircraft, called in-situ measurements---is now available. The main goal of this thesis is to develop new data analysis and processing techniques to apply to the model and new observation data, in order to improve CAT forecasting accuracy. This thesis shows that using in-situ data improves forecasting accuracy and that automated machine learning algorithms such as support vector machines (SVM), logistic regression, and random forests, can match current performance while eliminating almost all hand-tuning. Feature subset selection is paired with the new algorithms to choose diagnostics that predict well as a group rather than individually. Specializing forecasts and choice of diagnostics by geographic region further improves accuracy because of the geographic variation in turbulence sources. This work uses random forests to find climatologically-relevant regions based on these variations and implements a forecasting system testbed which brings these techniques together to rapidly prototype new, regionalized versions of operational CAT forecasting systems.

  11. [Substance-related and addictive disorders in the DSM-5].

    PubMed

    Thomasius, Rainer; Sack, Peter-Michael; Strittmatter, Esther; Kaess, Michael

    2014-03-01

    This paper concerns the revised classification of Substance-Related and Addictive Disorders in the fifth edition of the American Psychiatric Association's (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5). In DSM-5, substance use disorders are diagnosed on a continuum of severity specified by explicit operationalized diagnostic criteria. "Gambling disorder" is the only behavioral addiction added to the DSM. Furthermore, preliminary criteria for "Caffeine Use Disorder" and "Internet Gaming Disorder" have now been defined in the manual. Adopting the DSM-5 criteria catalogue within the German treatment system for children and adolescents with substance use disorders or at risk for developing substance use disorders would be of great significance. Since the diagnostic threshold is lower, more patients would be eligible for treatment. Thus, early intervention in the area of substance use disorders should be strengthened, a development that appears to be highly desirable from the perspective of child and adolescent psychiatry. The current Section III diagnoses, with their now comprehensive diagnostic criteria, facilitate more internationally compatible research.

  12. Chemical Structure and Surface Modification of Dendritic Nanomaterials Tailored for Therapeutic and Diagnostic Applications.

    PubMed

    Myung, Ja Hye; Hsu, Hao-Jui; Bugno, Jason; Tam, Kevin A; Hong, Seungpyo

    2017-01-01

    Dendritic nanomaterials have attracted a great deal of scientific interest due to their high capacity for multifunctionalization and potential in various biomedical applications, such as drug/gene delivery and diagnostic systems. Depending on the molecular structure and starting monomers, several different types of dendrimers have been developed, including poly(amidoamine) (PAMAM), poly(propylenimine) (PPI), and poly(L-lysine) (PLL) dendrimers, in addition to modified dendritic nanomaterials, such as Janus dendrimers and dendritic block copolymers. The chemical structure and surface modification of dendritic nanomaterials have been found to play a critical role in governing their biological behaviors. In this review, we present a comprehensive overview focusing on the synthesis and chemical structures of dendrimers and modified dendritic nanomaterials that are currently being investigated for drug delivery, gene delivery, and diagnostic applications. In addition, the impact of chemical surface modification and functionalization to the dendritic nanomaterials on their therapeutic and diagnostic applications are highlighted. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. Image processing and computer controls for video profile diagnostic system in the ground test accelerator (GTA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, R.M.; Zander, M.E.; Brown, S.K.

    1992-09-01

    This paper describes the application of video image processing to beam profile measurements on the Ground Test Accelerator (GTA). A diagnostic was needed to measure beam profiles in the intermediate matching section (IMS) between the radio-frequency quadrupole (RFQ) and the drift tube linac (DTL). Beam profiles are measured by injecting puffs of gas into the beam. The light emitted from the beam-gas interaction is captured and processed by a video image processing system, generating the beam profile data. A general purpose, modular and flexible video image processing system, imagetool, was used for the GTA image profile measurement. The development ofmore » both software and hardware for imagetool and its integration with the GTA control system (GTACS) will be discussed. The software includes specialized algorithms for analyzing data and calibrating the system. The underlying design philosophy of imagetool was tested by the experience of building and using the system, pointing the way for future improvements. The current status of the system will be illustrated by samples of experimental data.« less

  14. Image processing and computer controls for video profile diagnostic system in the ground test accelerator (GTA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, R.M.; Zander, M.E.; Brown, S.K.

    1992-01-01

    This paper describes the application of video image processing to beam profile measurements on the Ground Test Accelerator (GTA). A diagnostic was needed to measure beam profiles in the intermediate matching section (IMS) between the radio-frequency quadrupole (RFQ) and the drift tube linac (DTL). Beam profiles are measured by injecting puffs of gas into the beam. The light emitted from the beam-gas interaction is captured and processed by a video image processing system, generating the beam profile data. A general purpose, modular and flexible video image processing system, imagetool, was used for the GTA image profile measurement. The development ofmore » both software and hardware for imagetool and its integration with the GTA control system (GTACS) will be discussed. The software includes specialized algorithms for analyzing data and calibrating the system. The underlying design philosophy of imagetool was tested by the experience of building and using the system, pointing the way for future improvements. The current status of the system will be illustrated by samples of experimental data.« less

  15. [Diagnostic imaging of urolithiais. Current recommendations and new developments].

    PubMed

    Thalgott, M; Kurtz, F; Gschwend, J E; Straub, M

    2015-07-01

    Prevalence of urolithiasis is increasing in industrialized countries--in both adults and children, representing a unique diagnostic and therapeutic challenge. Risk-adapted diagnostic imaging currently means assessment with maximized sensitivity and specificity together with minimal radiation exposure. In clinical routine, imaging is performed by sonography, unenhanced computed tomography (NCCT) or intravenous urography (IVU) as well as plain kidney-ureter-bladder (KUB) radiographs. The aim of the present review is a critical guideline-based and therapy-aligned presentation of diagnostic imaging procedures for optimized treatment of urolithiasis considering the specifics in children and pregnant women.

  16. Diagnosis of prostate cancer via nanotechnological approach

    PubMed Central

    Kang, Benedict J; Jeun, Minhong; Jang, Gun Hyuk; Song, Sang Hoon; Jeong, In Gab; Kim, Choung-Soo; Searson, Peter C; Lee, Kwan Hyi

    2015-01-01

    Prostate cancer is one of the leading causes of cancer-related deaths among the Caucasian adult males in Europe and the USA. Currently available diagnostic strategies for patients with prostate cancer are invasive and unpleasant and have poor accuracy. Many patients have been overly or underly treated resulting in a controversy regarding the reliability of current conventional diagnostic approaches. This review discusses the state-of-the-art research in the development of novel noninvasive prostate cancer diagnostics using nanotechnology coupled with suggested diagnostic strategies for their clinical implication. PMID:26527873

  17. [Basics of Ear Surgery].

    PubMed

    Lailach, S; Zahnert, T

    2016-12-01

    The present article about the basics of ear surgery is a short overview of current indications, the required diagnostics and surgical procedures of common otologic diseases. In addition to plastic and reconstructive surgery of the auricle, principles of surgery of the external auditory canal, basics of middle ear surgery and the tumor surgery of the temporal bone are shown. Additionally, aspects of the surgical hearing rehabilitation (excluding implantable hearing systems) are presented considering current study results. Georg Thieme Verlag KG Stuttgart · New York.

  18. First step toward translation of thermophotonic lock-in imaging to dentistry as an early caries detection technology

    NASA Astrophysics Data System (ADS)

    Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima

    2016-09-01

    Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.

  19. The Palm Desert renewable [hydrogen] transportation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamberlin, C.E.; Lehman, P.

    1998-08-01

    This paper describes the Schatz Energy Research Center (SERC) progress on the Palm Desert Renewable Hydrogen Transportation System Project for the period June 1997 through May 1998. The project began in March 1996. The goal of the Palm Desert Project is to develop a clean and sustainable transportation system for a community. The project demonstrates the practical utility of hydrogen as a transportation fuel and the proton exchange membrane (PEM) fuel cell as a vehicle power system. The project includes designing and building 4 fuel cell powered vehicles, a solar hydrogen generating and refueling station, and a fuel cell vehiclemore » diagnostic center. Over this last year, SERC has built a fuel cell powered neighborhood electric vehicle and delivered it to the City of Palm Desert. The design of the hydrogen refueling station is near completion and it is anticipated that construction will be complete in the fall of 1998. The vehicles are currently being refueled at a temporary refueling station. The diagnostic center is being designed and maintenance procedures as well as computer diagnostic programs for the fuel cell vehicles are being developed. City employees are driving the vehicles daily and monitoring data are being collected. The drivers are pleased with the performance of the vehicles.« less

  20. Magnetic diagnostics for equilibrium reconstructions with eddy currents on the lithium tokamak experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitt, J. C., E-mail: jschmitt@pppl.gov; Lazerson, S.; Majeski, R.

    2014-11-15

    The Lithium Tokamak eXperiment is a spherical tokamak with a close-fitting low-recycling wall composed of thin lithium layers evaporated onto a stainless steel-lined copper shell. Long-lived non-axisymmetric eddy currents are induced in the shell and vacuum vessel by transient plasma and coil currents and these eddy currents influence both the plasma and the magnetic diagnostic signals that are used as constraints for equilibrium reconstruction. A newly installed set of re-entrant magnetic diagnostics and internal saddle flux loops, compatible with high-temperatures and lithium environments, is discussed. Details of the axisymmetric (2D) and non-axisymmetric (3D) treatments of the eddy currents and themore » equilibrium reconstruction are presented.« less

  1. Applications of antibodies in microfluidics-based analytical systems: challenges and strategies for success

    NASA Astrophysics Data System (ADS)

    O’Kennedy, Richard; Fitzgerald, Jenny; Cassedy, Arabelle; Crawley, Aoife; Zhang, Xin; Carrera, Sandro

    2018-06-01

    This review is designed to focus on antibodies and the attributes that make them ideal for applications in microfluidics-based diagnostic/separation platforms. The structures of different antibody formats and how they can be engineered to be highly effective in microfluidics-based environments will be highlighted. Suggested novel stratagems on the ideal way in which they can be employed in microfluidics systems, based on an informed knowledge of their structures and properties rather than random choice selection, as is often currently employed, will be provided. Finally, a critical assessment of current shortcomings in the approaches used along with possible ways for their resolution will be given.

  2. Activation of host immune responses in neonatal calves and interference with TB diagnostics after immunization with a commercial heat-killed vaccine

    USDA-ARS?s Scientific Manuscript database

    A major drawback of current whole-cell vaccines for Mycobacterium avium subsp. paratuberculosis is the potential interference with diagnostic tests for bovine tuberculosis and paratuberculosis. The current study was designed to explore cross-reactivity of the current USDA commercial vaccine for MAP ...

  3. Activation of host immune responses in neonatal calves and interference with TB diagnostics after immunization with a commercial heat-killed vaccine

    USDA-ARS?s Scientific Manuscript database

    A major drawback of current whole-cell vaccines for Mycobacterium avium subsp. paratuberculosis (MAP) is the potential interference with diagnostic tests for bovine tuberculosis and paratuberculosis. The current study was designed to explore cross-reactivity of the current USDA commercial vaccine fo...

  4. Induction motor broken rotor bar fault location detection through envelope analysis of start-up current using Hilbert transform

    NASA Astrophysics Data System (ADS)

    Abd-el-Malek, Mina; Abdelsalam, Ahmed K.; Hassan, Ola E.

    2017-09-01

    Robustness, low running cost and reduced maintenance lead Induction Motors (IMs) to pioneerly penetrate the industrial drive system fields. Broken rotor bars (BRBs) can be considered as an important fault that needs to be early assessed to minimize the maintenance cost and labor time. The majority of recent BRBs' fault diagnostic techniques focus on differentiating between healthy and faulty rotor cage. In this paper, a new technique is proposed for detecting the location of the broken bar in the rotor. The proposed technique relies on monitoring certain statistical parameters estimated from the analysis of the start-up stator current envelope. The envelope of the signal is obtained using Hilbert Transformation (HT). The proposed technique offers non-invasive, fast computational and accurate location diagnostic process. Various simulation scenarios are presented that validate the effectiveness of the proposed technique.

  5. Development of an intelligent diagnostic system for reusable rocket engine control

    NASA Technical Reports Server (NTRS)

    Anex, R. P.; Russell, J. R.; Guo, T.-H.

    1991-01-01

    A description of an intelligent diagnostic system for the Space Shuttle Main Engines (SSME) is presented. This system is suitable for incorporation in an intelligent controller which implements accommodating closed-loop control to extend engine life and maximize available performance. The diagnostic system architecture is a modular, hierarchical, blackboard system which is particularly well suited for real-time implementation of a system which must be repeatedly updated and extended. The diagnostic problem is formulated as a hierarchical classification problem in which the failure hypotheses are represented in terms of predefined data patterns. The diagnostic expert system incorporates techniques for priority-based diagnostics, the combination of analytical and heuristic knowledge for diagnosis, integration of different AI systems, and the implementation of hierarchical distributed systems. A prototype reusable rocket engine diagnostic system (ReREDS) has been implemented. The prototype user interface and diagnostic performance using SSME test data are described.

  6. A method for determining poloidal rotation from poloidal asymmetry in toroidal rotation (invited)

    DOE PAGES

    Chrystal, Chrystal; Burrell, Keith H.; Grierson, Brian A.; ...

    2014-08-08

    A new diagnostic has been developed on DIII-D that determines the impurity poloidal rotation from the poloidal asymmetry in the toroidal angular rotation velocity. This asymmetry is measured with recently added tangential charge exchange viewchords on the high-field side of the tokamak midplane. Measurements are made on co- and counter-current neutral beams, allowing the charge exchange cross section effect to be measured and eliminating the need for atomic physics calculations. The diagnostic implementation on DIII-D restricts the measurement range to the core (r/a < 0.6) where, relative to measurements made with the vertical charge exchange system, the spatial resolution ismore » improved. Furthermore, significant physics results have been obtained with this new diagnostic; for example, poloidal rotation measurements that significantly exceed neoclassical predictions.« less

  7. HIDRA-MAT: A Material Analysis Tool for Fusion Devices

    NASA Astrophysics Data System (ADS)

    Andruczyk, Daniel; Rizkallah, Rabel; Bedoya, Felipe; Kapat, Aveek; Schamis, Hanna; Allain, Jean Paul

    2017-10-01

    The former WEGA stellarator which is now operating as HIDRA at the University of Illinois will be almost exclusively used to study the intimate relationship between the plasma interacting with surfaces of different materials. A Material Analysis Tool (HIDRA-MAT) is being designed and will be built based on the successful Material Analysis and Particle Probe (MAPP) which is currently used on NSTX-U at PPPL. This will be an in-situ material diagnostic probe, meaning that all analysis can be done without breaking vacuum. This allows surface changes to be studied in real-time. HIDRA-MAT will consist of several in-situ diagnostics including Langmuir probes (LP), Thermal Desorption Spectroscopy (TDS), X-ray Photo Spectroscopy (XPS) and Ion Scattering Spectroscopy (ISS). This presentation will outline the HIDRA-MAT diagnostic and initial design, as well as its integration into the HIDRA system.

  8. An informatics model for guiding assembly of telemicrobiology workstations for malaria collaborative diagnostics using commodity products and open-source software.

    PubMed

    Suhanic, West; Crandall, Ian; Pennefather, Peter

    2009-07-17

    Deficits in clinical microbiology infrastructure exacerbate global infectious disease burdens. This paper examines how commodity computation, communication, and measurement products combined with open-source analysis and communication applications can be incorporated into laboratory medicine microbiology protocols. Those commodity components are all now sourceable globally. An informatics model is presented for guiding the use of low-cost commodity components and free software in the assembly of clinically useful and usable telemicrobiology workstations. The model incorporates two general principles: 1) collaborative diagnostics, where free and open communication and networking applications are used to link distributed collaborators for reciprocal assistance in organizing and interpreting digital diagnostic data; and 2) commodity engineering, which leverages globally available consumer electronics and open-source informatics applications, to build generic open systems that measure needed information in ways substantially equivalent to more complex proprietary systems. Routine microscopic examination of Giemsa and fluorescently stained blood smears for diagnosing malaria is used as an example to validate the model. The model is used as a constraint-based guide for the design, assembly, and testing of a functioning, open, and commoditized telemicroscopy system that supports distributed acquisition, exploration, analysis, interpretation, and reporting of digital microscopy images of stained malarial blood smears while also supporting remote diagnostic tracking, quality assessment and diagnostic process development. The open telemicroscopy workstation design and use-process described here can address clinical microbiology infrastructure deficits in an economically sound and sustainable manner. It can boost capacity to deal with comprehensive measurement of disease and care outcomes in individuals and groups in a distributed and collaborative fashion. The workstation enables local control over the creation and use of diagnostic data, while allowing for remote collaborative support of diagnostic data interpretation and tracking. It can enable global pooling of malaria disease information and the development of open, participatory, and adaptable laboratory medicine practices. The informatic model highlights how the larger issue of access to generic commoditized measurement, information processing, and communication technology in both high- and low-income countries can enable diagnostic services that are much less expensive, but substantially equivalent to those currently in use in high-income countries.

  9. STATUS OF VARIOUS SNS DIAGNOSTIC SYSTEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blokland, Willem; Purcell, J David; Patton, Jeff

    2007-01-01

    The Spallation Neutron Source (SNS) accelerator systems are ramping up to deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. Enhancements or additions have been made to several instrument systems to support the ramp up in intensity, improve reliability, and/or add functionality. The Beam Current Monitors now support increased rep rates, the Harp system now includes charge density calculations for the target, and a new system has been created to collect data for the beam accounting and present the data over the web and to the operator consoles. The majority of themore » SNS beam instruments are PC-based and their configuration files are now managed through the Oracle relational database. A new version for the wire scanner software was developed to add features to correlate the scan with beam loss, parking in the beam, and measuring the longitudinal beam current. This software is currently being tested. This paper also includes data from the selected instruments.« less

  10. [work motivation -- assessment instruments and their relevance for medical care].

    PubMed

    Fiedler, Rolf G; Ranft, Andreas; Greitemann, Bernhard; Heuft, Gereon

    2005-11-01

    The relevance of work motivation for medical research and healthcare, in particular rehabilitation, is described. Four diagnostic instruments in the German language are introduced which can assess work motivation using a scale system: AVEM, JDS, LMI and FBTM. Their possible application and potential usage for the clinical area are discussed. Apart from the FBTM, none of these instruments can be directly used as a general instrument in a normal medical clinical setting. Finally, a current model for work motivation (compensatory model of work motivation and volition) is presented that contains basis concepts, which are judged as important for future research questions concerning the development of motivation diagnostic instruments.

  11. Software Tools to Support the Assessment of System Health

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.

    2013-01-01

    This presentation provides an overview of three software tools that were developed by the NASA Glenn Research Center to support the assessment of system health: the Propulsion Diagnostic Method Evaluation Strategy (ProDIMES), the Systematic Sensor Selection Strategy (S4), and the Extended Testability Analysis (ETA) tool. Originally developed to support specific NASA projects in aeronautics and space, these software tools are currently available to U.S. citizens through the NASA Glenn Software Catalog. The ProDiMES software tool was developed to support a uniform comparison of propulsion gas path diagnostic methods. Methods published in the open literature are typically applied to dissimilar platforms with different levels of complexity. They often address different diagnostic problems and use inconsistent metrics for evaluating performance. As a result, it is difficult to perform a one ]to ]one comparison of the various diagnostic methods. ProDIMES solves this problem by serving as a theme problem to aid in propulsion gas path diagnostic technology development and evaluation. The overall goal is to provide a tool that will serve as an industry standard, and will truly facilitate the development and evaluation of significant Engine Health Management (EHM) capabilities. ProDiMES has been developed under a collaborative project of The Technical Cooperation Program (TTCP) based on feedback provided by individuals within the aircraft engine health management community. The S4 software tool provides a framework that supports the optimal selection of sensors for health management assessments. S4 is structured to accommodate user ]defined applications, diagnostic systems, search techniques, and system requirements/constraints. One or more sensor suites that maximize this performance while meeting other user ]defined system requirements that are presumed to exist. S4 provides a systematic approach for evaluating combinations of sensors to determine the set or sets of sensors that optimally meet the performance goals and the constraints. It identifies optimal sensor suite solutions by utilizing a merit (i.e., cost) function with one of several available optimization approaches. As part of its analysis, S4 can expose fault conditions that are difficult to diagnose due to an incomplete diagnostic philosophy and/or a lack of sensors. S4 was originally developed and applied to liquid rocket engines. It was subsequently used to study the optimized selection of sensors for a simulation ]based aircraft engine diagnostic system. The ETA Tool is a software ]based analysis tool that augments the testability analysis and reporting capabilities of a commercial ]off ]the ]shelf (COTS) package. An initial diagnostic assessment is performed by the COTS software using a user ]developed, qualitative, directed ]graph model of the system being analyzed. The ETA Tool accesses system design information captured within the model and the associated testability analysis output to create a series of six reports for various system engineering needs. These reports are highlighted in the presentation. The ETA Tool was developed by NASA to support the verification of fault management requirements early in the Launch Vehicle process. Due to their early development during the design process, the TEAMS ]based diagnostic model and the ETA Tool were able to positively influence the system design by highlighting gaps in failure detection, fault isolation, and failure recovery.

  12. Department of Defense picture archiving and communication system acceptance testing: results and identification of problem components.

    PubMed

    Allison, Scott A; Sweet, Clifford F; Beall, Douglas P; Lewis, Thomas E; Monroe, Thomas

    2005-09-01

    The PACS implementation process is complicated requiring a tremendous amount of time, resources, and planning. The Department of Defense (DOD) has significant experience in developing and refining PACS acceptance testing (AT) protocols that assure contract compliance, clinical safety, and functionality. The DOD's AT experience under the initial Medical Diagnostic Imaging Support System contract led to the current Digital Imaging Network-Picture Archiving and Communications Systems (DIN-PACS) contract AT protocol. To identify the most common system and component deficiencies under the current DIN-PACS AT protocol, 14 tri-service sites were evaluated during 1998-2000. Sixteen system deficiency citations with 154 separate types of limitations were noted with problems involving the workstation, interfaces, and the Radiology Information System comprising more than 50% of the citations. Larger PACS deployments were associated with a higher number of deficiencies. The most commonly cited systems deficiencies were among the most expensive components of the PACS.

  13. Operational seasonal and interannual predictions of ocean conditions

    NASA Technical Reports Server (NTRS)

    Leetmaa, Ants

    1992-01-01

    Dr. Leetmaa described current work at the U.S. National Meteorological Center (NMC) on coupled systems leading to a seasonal prediction system. He described the way in which ocean thermal data is quality controlled and used in a four dimensional data assimilation system. This consists of a statistical interpolation scheme, a primitive equation ocean general circulation model, and the atmospheric fluxes that are required to force this. This whole process generated dynamically consist thermohaline and velocity fields for the ocean. Currently routine weekly analyses are performed for the Atlantic and Pacific oceans. These analyses are used for ocean climate diagnostics and as initial conditions for coupled forecast models. Specific examples of output products were shown both in the Pacific and the Atlantic Ocean.

  14. National Spherical Torus Experiment (NSTX) Facility/Diagnostic Overview

    NASA Astrophysics Data System (ADS)

    Ono, M.

    2005-10-01

    The capabilities of the NSTX experimental facility and diagnostics continue to improve. The new TF joints are performing well at 4.5 kG. New in-board shaping coils were installed to produce plasmas with simultaneously high elongation ˜2.5 and high triangularity ˜0.8 needed for advanced operation. The EFC/RWM system with six external coils driven by three switching power amplifiers (1 kHz, 6 kA-turn) is now fully operational. With these new tools, we significantly expanded the NSTX operating parameters, achieving the highest controlled elongation of 2.75, a shape factor q95Ip/aBT of 37 MA/m-T, plasma volume of 14 m^3, stored energy of 430 kJ, normalized beta of 7.4 % MA/m-T, bootstrap current fraction of 60 % at 700 kA, and longest plasma pulse length of 1.5 s or about 4 times the resistive skin time. In the area of the plasma diagnostics, ten additional Thomson scattering channels are providing detailed measurement of the H-mode pedestal and internal barrier regions. The 8 channel MSE diagnostic is providing crucial j(r) measurements including high electron confinement reversed shear plasmas. A tangential microwave scattering system to measure electron-transport- relevant fluctuations is being commissioned.

  15. DIAGNOSTICS OF BNL ERL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POZDEYEV,E.; BEN-ZVI, I.; CAMERON, P.

    2007-06-25

    The ERL Prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high-intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high-current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This paper outlinesmore » requirements on the ERL diagnostics and describes its setup and modes of operation.« less

  16. Fetal alcohol spectrum disorder: Canadian guidelines for diagnosis

    PubMed Central

    Chudley, Albert E.; Conry, Julianne; Cook, Jocelynn L.; Loock, Christine; Rosales, Ted; LeBlanc, Nicole

    2005-01-01

    THE DIAGNOSIS OF FETAL ALCOHOL SPECTRUM DISORDER (FASD) is complex and guidelines are warranted. A subcommittee of the Public Health Agency of Canada's National Advisory Committee on Fetal Alcohol Spectrum Disorder reviewed, analysed and integrated current approaches to diagnosis to reach agreement on a standard in Canada. The purpose of this paper is to review and clarify the use of current diagnostic systems and make recommendations on their application for diagnosis of FASD-related disabilities in people of all ages. The guidelines are based on widespread consultation of expert practitioners and partners in the field. The guidelines have been organized into 7 categories: screening and referral; the physical examination and differential diagnosis; the neurobehavioural assessment; and treatment and follow-up; maternal alcohol history in pregnancy; diagnostic criteria for fetal alcohol syndrome (FAS), partial FAS and alcohol-related neurodevelopmental disorder; and harmonization of Institute of Medicine and 4-Digit Diagnostic Code approaches. The diagnosis requires a comprehensive history and physical and neurobehavioural assessments; a multidisciplinary approach is necessary. These are the first Canadian guidelines for the diagnosis of FAS and its related disabilities, developed by broad-based consultation among experts in diagnosis. PMID:15738468

  17. Use of Fuzzy Logic Systems for Assessment of Primary Faults

    NASA Astrophysics Data System (ADS)

    Petrović, Ivica; Jozsa, Lajos; Baus, Zoran

    2015-09-01

    In electric power systems, grid elements are often subjected to very complex and demanding disturbances or dangerous operating conditions. Determining initial fault or cause of those states is a difficult task. When fault occurs, often it is an imperative to disconnect affected grid element from the grid. This paper contains an overview of possibilities for using fuzzy logic in an assessment of primary faults in the transmission grid. The tool for this task is SCADA system, which is based on information of currents, voltages, events of protection devices and status of circuit breakers in the grid. The function model described with the membership function and fuzzy logic systems will be presented in the paper. For input data, diagnostics system uses information of protection devices tripping, states of circuit breakers and measurements of currents and voltages before and after faults.

  18. DMS augmented monitoring and diganosis application (DMS AMDA) prototype

    NASA Technical Reports Server (NTRS)

    Patterson-Hine, F. A.; Boyd, Mark A.; Iverson, David L.; Donnell, Brian; Lauritsen, Janet; Doubek, Sharon; Gibson, Jim; Monahan, Christine; Rosenthal, Donald A.

    1993-01-01

    The Data Management System Augmented Monitoring and Diagnosis Application (DMS AMDA) is currently under development at NASA Ames Research Center (ARC). It will provide automated monitoring and diagnosis capabilities for the Space Station Freedom (SSF) Data Management System (DMS) in the Control Center Complex (CCC) at NASA Johnson Space Center. Several advanced automation applications are under development for use in the CCC for other SSF subsystems. The DMS AMDA, however, is the first application to utilize digraph failure analysis techniques and the Extended Realtime FEAT (ERF) application as the core of its diagnostic system design, since the other projects were begun before the digraph tools were available. Model-based diagnosis and expert systems techniques will provide additional capabilities and augment ERF where appropriate. Utilization of system knowledge captured in the design phase of a system in digraphs should result in both a cost savings and a technical advantage during implementation of the diagnostic software. This paper addresses both the programmatic and technical considerations of this approach, and describes the software design and initial prototyping effort.

  19. Use of evidence-based assessments for childhood anxiety disorders within a regional medical system.

    PubMed

    Sattler, Adam F; Ale, Chelsea M; Nguyen, Kristin; Gregg, Melissa S; Geske, Jennifer R; Whiteside, Stephen P H

    2016-11-01

    Anxiety disorders represent a common and serious threat to mental health in children and adolescents. To effectively treat anxiety in children, clinicians must conduct accurate assessment of patients' symptoms. However, despite the importance of assessment in the treatment of childhood anxiety disorders, the literature lacks a thorough analysis of the practices used by clinicians' when evaluating such disorders in community settings. Thus, the current study examines the quality of assessment for childhood anxiety disorders in a large regional health system. The results suggest that clinicians often provide non-specific diagnoses, infrequently document symptoms according to diagnostic criteria, and rarely administer rating scales and structured diagnostic interviews. Relatedly, diagnostic agreement across practice settings was low. Finally, the quality of assessment differed according to the setting in which the assessment was conducted and the complexity of the patient's symptomatology. These results highlight the need to develop and disseminate clinically feasible evidence-based assessment practices that can be implemented within resource-constrained service settings. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. Introducing a New Classification of Early Childhood Disorders: DC:0-5™

    ERIC Educational Resources Information Center

    Zeanah, Charles H.; Carter, Alice S.; Cohen, Julie; Egger, Helen; Gleason, Mary Margaret; Keren, Miri; Lieberman, Alicia; Mulrooney, Kathleen; Oser, Cindy

    2017-01-01

    This article introduces the revised and updated "DC:0-5™: Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood." The authors describe the past and current efforts to create a developmentally based classification system for very young children. DC:0-3, published in 1994 by ZERO TO THREE,…

  1. Artificial Intelligence Technology for the Maintainer's Associate. Final Report for the Period October 1983 to December 1985.

    ERIC Educational Resources Information Center

    Richardson, J. Jeffrey; And Others

    In keeping with current Department of Defense policies on integrated diagnostics and a reduced reliance on paper-based documentation, the concept of a portable, expert-system-based job aid and training device was proposed to assist inexperienced electronics maintenance technicians in learning to maintain sophisticated equipment. A prototype was…

  2. [Ankyloblepharon filiforme adnatum].

    PubMed

    Haustein, M; Reschke, F; Terai, N; Lesczcynska, A; Wozniak, K; Pillunat, L E; Sommer, F

    2014-02-01

    The ankyloblepharon filiforme adnatum is a congenital eyelid anomaly in which the development of the eyelids is completed but the eyelids are not completely separated at birth. The abnormality can occur as an isolated anomaly, together with other eye diseases or in the context of systemic syndromes. In this case report the current classification and essential diagnostics of AFA will be reviewed.

  3. Exudative pleural diseases in small animals.

    PubMed

    Epstein, Steven E

    2014-01-01

    Exudative pleural diseases are a common cause of respiratory distress and systemic illness in dogs and cats. This article addresses the pathophysiology, development, and classification of exudative pleural effusions. The most current diagnostic strategies, causes, imaging findings, and medical or surgical treatment options for select diseases are reviewed in detail. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Brief Report: Symptom Onset Patterns and Functional Outcomes in Young Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Shumway, Stacy; Thurm, Audrey; Swedo, Susan E.; Deprey, Lesley; Barnett, Lou Ann; Amaral, David G.; Rogers, Sally J.; Ozonoff, Sally

    2011-01-01

    This study examined the relationship between onset status and current functioning using a recently proposed onset classification system in 272 young children with autism spectrum disorder (ASD). Participants were classified into one of the following groups, based on parent report using the Autism Diagnostic Interview-Revised: Early Onset (symptoms…

  5. The production of radionuclides for nuclear medicine from a compact, low-energy accelerator system.

    PubMed

    Webster, William D; Parks, Geoffrey T; Titov, Dmitry; Beasley, Paul

    2014-05-01

    The field of nuclear medicine is reliant on radionuclides for medical imaging procedures and radioimmunotherapy (RIT). The recent shut-downs of key radionuclide producers have highlighted the fragility of the current radionuclide supply network, however. To ensure that nuclear medicine can continue to grow, adding new diagnostic and therapy options to healthcare, novel and reliable production methods are required. Siemens are developing a low-energy, high-current - up to 10 MeV and 1 mA respectively - accelerator. The capability of this low-cost, compact system for radionuclide production, for use in nuclear medicine procedures, has been considered. The production of three medically important radionuclides - (89)Zr, (64)Cu, and (103)Pd - has been considered, via the (89)Y(p,n), (64)Ni(p,n) and (103)Rh(p,n) reactions, respectively. Theoretical cross-sections were generated using TALYS and compared to experimental data available from EXFOR. Stopping power values generated by SRIM have been used, with the TALYS-generated excitation functions, to calculate potential yields and isotopic purity in different irradiation regimes. The TALYS excitation functions were found to have a good agreement with the experimental data available from the EXFOR database. It was found that both (89)Zr and (64)Cu could be produced with high isotopic purity (over 99%), with activity yields suitable for medical diagnostics and therapy, at a proton energy of 10MeV. At 10MeV, the irradiation of (103)Rh produced appreciable quantities of (102)Pd, reducing the isotopic purity. A reduction in beam energy to 9.5MeV increased the radioisotopic purity to 99% with only a small reduction in activity yield. This work demonstrates that the low-energy, compact accelerator system under development by Siemens would be capable of providing sufficient quantities of (89)Zr, (64)Cu, and (103)Pd for use in medical diagnostics and therapy. It is suggested that the system could be used to produce many other isotopes currently useful to nuclear medicine. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Current trends in molecular diagnostics of chronic myeloid leukemia.

    PubMed

    Vinhas, Raquel; Cordeiro, Milton; Pedrosa, Pedro; Fernandes, Alexandra R; Baptista, Pedro V

    2017-08-01

    Nearly 1.5 million people worldwide suffer from chronic myeloid leukemia (CML), characterized by the genetic translocation t(9;22)(q34;q11.2), involving the fusion of the Abelson oncogene (ABL1) with the breakpoint cluster region (BCR) gene. Early onset diagnosis coupled to current therapeutics allow for a treatment success rate of 90, which has focused research on the development of novel diagnostics approaches. In this review, we present a critical perspective on current strategies for CML diagnostics, comparing to gold standard methodologies and with an eye on the future trends on nanotheranostics.

  7. Development of the Yale Food Addiction Scale Version 2.0.

    PubMed

    Gearhardt, Ashley N; Corbin, William R; Brownell, Kelly D

    2016-02-01

    Parallels in biological, psychological, and behavioral systems have led to the hypothesis that an addictive process may contribute to problematic eating. The Yale Food Addiction Scale (YFAS) was developed to provide a validated measure of addictive-like eating behavior based upon the diagnostic criteria for substance dependence. Recently, the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5) was released, which included significant changes to the substance-related and addictive disorders (SRAD) section. In the current study, the YFAS 2.0 was developed to maintain consistency with the current diagnostic understanding of addiction and to improve the psychometric properties of the original YFAS. In a sample of 550 participants, 14.6% met criteria for food addiction. The YFAS 2.0 demonstrated good internal consistency, as well as convergent, discriminant, and incremental validity. Elevated scores on the YFAS 2.0 were associated with higher rates of obesity and more severe pathological eating (e.g., binge eating). The YFAS 2.0 also appeared to capture a related, but unique construct relative to traditional eating disorders. In a separate sample of 209 participants, the YFAS and YFAS 2.0 were directly compared. Both versions of the YFAS were similarly associated with elevated body mass index, binge eating, and weight cycling. However, exceeding the food addiction threshold was more strongly associated with obesity for the YFAS 2.0 than the original YFAS. Thus, the YFAS 2.0 appears to by a psychometrically sound measure that reflects the current diagnostic understanding of addiction to further investigate the potential role of an addictive process in problematic eating behavior. (c) 2016 APA, all rights reserved).

  8. BREAST: a novel method to improve the diagnostic efficacy of mammography

    NASA Astrophysics Data System (ADS)

    Brennan, P. C.; Tapia, K.; Ryan, J.; Lee, W.

    2013-03-01

    High quality breast imaging and accurate image assessment are critical to the early diagnoses, treatment and management of women with breast cancer. Breast Screen Reader Assessment Strategy (BREAST) provides a platform, accessible by researchers and clinicians world-wide, which will contain image data bases, algorithms to assess reader performance and on-line systems for image evaluation. The platform will contribute to the diagnostic efficacy of breast imaging in Australia and beyond on two fronts: reducing errors in mammography, and transforming our assessment of novel technologies and techniques. Mammography is the primary diagnostic tool for detecting breast cancer with over 800,000 women X-rayed each year in Australia, however, it fails to detect 30% of breast cancers with a number of missed cancers being visible on the image [1-6]. BREAST will monitor the mistakes, identify reasons for mammographic errors, and facilitate innovative solutions to reduce error rates. The BREAST platform has the potential to enable expert assessment of breast imaging innovations, anywhere in the world where experts or innovations are located. Currently, innovations are often being assessed by limited numbers of individuals who happen to be geographically located close to the innovation, resulting in equivocal studies with low statistical power. BREAST will transform this current paradigm by enabling large numbers of experts to assess any new method or technology using our embedded evaluation methods. We are confident that this world-first system will play an important part in the future efficacy of breast imaging.

  9. [The development of a finger joint phantom for the optical simulation of early inflammatory rheumatic changes].

    PubMed

    Prapavat, V; Runge, W; Mans, J; Krause, A; Beuthan, J; Müller, G

    1997-11-01

    In the field of rheumatology, conventional diagnostic methods permit the detection only of advanced stages of the disease, which is at odds with the current clinical demand for the early diagnosis of inflammatory rheumatic diseases. Prompted by current needs, we developed a finger joint phantom that enables the optical and geometrical simulation of an early stage of rheumatoid arthritis (RA). The results presented here form the experimental basis for an evaluation of new RA diagnostic systems based on near infrared light. The early stage of RA is characterised mainly by a vigorous proliferation of the synovial membrane and clouding of the synovial fluid. Using a double-integrating-sphere technique, the absorption and scattering coefficients (mua, mus') are experimentally determined for healthy and pathologically altered synovial fluid and capsule tissue. Using a variable mixture of Intralipid Indian ink and water as a scattering/absorption medium, the optical properties of skin, synovial fluid or capsule can be selected individually. Since the optical and geometrical properties of bone tissue remain constant in early-stage RA, a solid material is used for its simulation. Using the finger joint phantom described herein, the optical properties of joint regions can be adjusted specifically, enabling an evaluation of their effects on an optical signal--for example, during fluorography--and the investigation of these effects for diagnostically useful information. The experimental foundation for the development of a new optical system for the early diagnosis of RA has now been laid.

  10. Nucleic acid probes in diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Oberry, Phillip A.

    1991-01-01

    The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

  11. Neurocutaneous Disorders.

    PubMed

    Rosser, Tena

    2018-02-01

    This article presents an up-to-date summary of the genetic etiology, diagnostic criteria, clinical features, and current management recommendations for the most common neurocutaneous disorders encountered in clinical adult and pediatric neurology practices. The phakomatoses are a phenotypically and genetically diverse group of multisystem disorders that primarily affect the skin and central nervous system. A greater understanding of the genetic and biological underpinnings of numerous neurocutaneous disorders has led to better clinical characterization, more refined diagnostic criteria, and improved treatments in neurofibromatosis type 1, Legius syndrome, neurofibromatosis type 2, Noonan syndrome with multiple lentigines, tuberous sclerosis complex, Sturge-Weber syndrome, and incontinentia pigmenti. Neurologists require a basic knowledge of and familiarity with a wide variety of neurocutaneous disorders because of the frequent involvement of the central and peripheral nervous systems. A simple routine skin examination can often open a broad differential diagnosis and lead to improved patient care.

  12. Beam transport and monitoring for laser plasma accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, K.; Sokollik, T.; Tilborg, J. van

    The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system,more » XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.« less

  13. Conceptual Design of the ITER ECE Diagnostic - An Update

    NASA Astrophysics Data System (ADS)

    Austin, M. E.; Pandya, H. K. B.; Beno, J.; Bryant, A. D.; Danani, S.; Ellis, R. F.; Feder, R.; Hubbard, A. E.; Kumar, S.; Ouroua, A.; Phillips, P. E.; Rowan, W. L.

    2012-09-01

    The ITER ECE diagnostic has recently been through a conceptual design review for the entire system including front end optics, transmission line, and back-end instruments. The basic design of two viewing lines, each with a single ellipsoidal mirror focussing into the plasma near the midplane of the typical operating scenarios is agreed upon. The location and design of the hot calibration source and the design of the shutter that directs its radiation to the transmission line are issues that need further investigation. In light of recent measurements and discussion, the design of the broadband transmission line is being revisited and new options contemplated. For the instruments, current systems for millimeter wave radiometers and broad-band spectrometers will be adequate for ITER, but the option for employing new state-of-the-art techniques will be left open.

  14. Diagnosis and therapy with CRISPR advanced CRISPR based tools for point of care diagnostics and early therapies.

    PubMed

    Uppada, Vanita; Gokara, Mahesh; Rasineni, Girish Kumar

    2018-05-20

    Molecular diagnostics is of critical importance to public health worldwide. It facilitates not only detection and characterization of diseases, but also monitors drug responses, assists in the identification of genetic modifiers and disease susceptibility. Based upon DNA variation, a wide range of molecular-based tests are available to assess/diagnose diseases. The CRISPR-Cas9 system has recently emerged as a versatile tool for biological and medical research. In this system, a single guide RNA (sgRNA) directs the endonuclease Cas9 to a targeted DNA sequence for site-specific manipulation. As designing CRISPR-guided nucleases can be done easily and relatively fast, the CRISPR/Cas9 system has evolved as widely used DNA editing tool. This technique led to a large number of gene editing studies in variety of organisms. CRISPR/Cas9-mediated diagnosis and therapy has picked up pace due to specificity and accuracy of CRISPR. The aim is not only to identify specific pathogens, especially virus but also to repair disease-causing alleles by changing the DNA sequence at the exact location on the chromosome. At present, PCR-based molecular diagnostic testing predominates; however, alternative technologies aimed at reducing genome complexity without PCR are anticipated to gain momentum in the coming years. Furthermore, development of integrated chip devices should allow point-of-care testing and facilitate genetic readouts from single cells and molecules. Together with molecular based therapy CRISPR based diagnostic testing will be a revolution in modern health care settings. In this review, we emphasize on current developing diagnostic techniques based upon CRISPR Cas approach along with short insights on its therapeutic usage. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Large Volume Non-Equilibrium Air Plasma at Atmospheric Pressure: A Novel Method with Low Power Requirements

    DTIC Science & Technology

    2007-02-28

    of magnitude in size. Also unlike corona -like devices such as the plasma needle , which generates 2-3 mm long plasma at the tip of a sharp wire...Distribution Unlimited Table of Contents Abstract AC System with Water Electrode Current voltage characteristics Plasma diagnostics results Experimental setup...Laroussi, PI. 4 AC SYSTEM WITH WATER ELECTRODE Recently, non-equilibrium atmospheric pressure plasmas have been used in a variety of material processing

  16. Determination of eddy current response with magnetic measurements.

    PubMed

    Jiang, Y Z; Tan, Y; Gao, Z; Nakamura, K; Liu, W B; Wang, S Z; Zhong, H; Wang, B B

    2017-09-01

    Accurate mutual inductances between magnetic diagnostics and poloidal field coils are an essential requirement for determining the poloidal flux for plasma equilibrium reconstruction. The mutual inductance calibration of the flux loops and magnetic probes requires time-varying coil currents, which also simultaneously drive eddy currents in electrically conducting structures. The eddy current-induced field appearing in the magnetic measurements can substantially increase the calibration error in the model if the eddy currents are neglected. In this paper, an expression of the magnetic diagnostic response to the coil currents is used to calibrate the mutual inductances, estimate the conductor time constant, and predict the eddy currents response. It is found that the eddy current effects in magnetic signals can be well-explained by the eddy current response determination. A set of experiments using a specially shaped saddle coil diagnostic are conducted to measure the SUNIST-like eddy current response and to examine the accuracy of this method. In shots that include plasmas, this approach can more accurately determine the plasma-related response in the magnetic signals by eliminating the field due to the eddy currents produced by the external field.

  17. The way to universal and correct medical presentation of diagnostic informations for complex spectrophotometry noninvasive medical diagnostic systems

    NASA Astrophysics Data System (ADS)

    Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.

    2003-07-01

    The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.

  18. Langmuir Probe Diagnostics of Pulsed Plasma Doping System

    NASA Astrophysics Data System (ADS)

    Lei, Yu; Overzet, Lawrence J.; Felch, Susan B.; Fang, Ziwei; Koo, Bon-Woong; Goeckner, Matthew J.

    2002-10-01

    Pulsed plasma doping (P2LAD) is a potential solution to implement ultra-shallow junctions. In this study, Langmuir probe diagnostics techniques were investigated thoroughly for its application to P2LAD system, and the current sensing scheme using batteries and a 'downstairs' load resistor turned out to be the most reliable. Severe limitations of current transformers were found in diagnostics of pulsed plasma. A floating probe was proven to be good at monitoring the disturbances of the Langmuir probe and the cathode voltage. With the above technique, time-resolved Langmuir probe measurements have been carried out in a P2LAD system. The Langmuir probe data in Ar plasma indicate that during a 20 microns long implant pulse the plasma density ranges from 1E9 1E10 cm-3 and the electron temperature ranges from 0.4 to 14 eV. Between the pulses, the density keeps at the high level for 30 ms and then decays exponentially until reaching the range of 3E8 1E9 cm-3, which demonstrates the presence of residual plasma between pulses. A non-zero plasma density during the afterglow is also observed for BF3 plasma. Significant amounts of primary electron and electron beams are present during the ignition and ensuing steady region in both Ar and BF3 plasmas while they are much stronger in BF3 plasma. Plasma density is observed to increase with cathode voltage and pressure while the electron temperature is mainly influenced by the pressure. An overshoot of the cathode voltage during the afterglow region was found, and it significantly influences the plasma potential during the afterglow.

  19. Diagnostic Tests to Support Late-Stage Control Programs for Schistosomiasis and Soil-Transmitted Helminthiases.

    PubMed

    Hawkins, Kenneth R; Cantera, Jason L; Storey, Helen L; Leader, Brandon T; de Los Santos, Tala

    2016-12-01

    Global efforts to address schistosomiasis and soil-transmitted helminthiases (STH) include deworming programs for school-aged children that are made possible by large-scale drug donations. Decisions on these mass drug administration (MDA) programs currently rely on microscopic examination of clinical specimens to determine the presence of parasite eggs. However, microscopy-based methods are not sensitive to the low-intensity infections that characterize populations that have undergone MDA. Thus, there has been increasing recognition within the schistosomiasis and STH communities of the need for improved diagnostic tools to support late-stage control program decisions, such as when to stop or reduce MDA. Failure to adequately address the need for new diagnostics could jeopardize achievement of the 2020 London Declaration goals. In this report, we assess diagnostic needs and landscape potential solutions and determine appropriate strategies to improve diagnostic testing to support control and elimination programs. Based upon literature reviews and previous input from experts in the schistosomiasis and STH communities, we prioritized two diagnostic use cases for further exploration: to inform MDA-stopping decisions and post-MDA surveillance. To this end, PATH has refined target product profiles (TPPs) for schistosomiasis and STH diagnostics that are applicable to these use cases. We evaluated the limitations of current diagnostic methods with regards to these use cases and identified candidate biomarkers and diagnostics with potential application as new tools. Based on this analysis, there is a need to develop antigen-detecting rapid diagnostic tests (RDTs) with simplified, field-deployable sample preparation for schistosomiasis. Additionally, there is a need for diagnostic tests that are more sensitive than the current methods for STH, which may include either a field-deployable molecular test or a simple, low-cost, rapid antigen-detecting test.

  20. Next-Generation Climate Modeling Science Challenges for Simulation, Workflow and Analysis Systems

    NASA Astrophysics Data System (ADS)

    Koch, D. M.; Anantharaj, V. G.; Bader, D. C.; Krishnan, H.; Leung, L. R.; Ringler, T.; Taylor, M.; Wehner, M. F.; Williams, D. N.

    2016-12-01

    We will present two examples of current and future high-resolution climate-modeling research that are challenging existing simulation run-time I/O, model-data movement, storage and publishing, and analysis. In each case, we will consider lessons learned as current workflow systems are broken by these large-data science challenges, as well as strategies to repair or rebuild the systems. First we consider the science and workflow challenges to be posed by the CMIP6 multi-model HighResMIP, involving around a dozen modeling groups performing quarter-degree simulations, in 3-member ensembles for 100 years, with high-frequency (1-6 hourly) diagnostics, which is expected to generate over 4PB of data. An example of science derived from these experiments will be to study how resolution affects the ability of models to capture extreme-events such as hurricanes or atmospheric rivers. Expected methods to transfer (using parallel Globus) and analyze (using parallel "TECA" software tools) HighResMIP data for such feature-tracking by the DOE CASCADE project will be presented. A second example will be from the Accelerated Climate Modeling for Energy (ACME) project, which is currently addressing challenges involving multiple century-scale coupled high resolution (quarter-degree) climate simulations on DOE Leadership Class computers. ACME is anticipating production of over 5PB of data during the next 2 years of simulations, in order to investigate the drivers of water cycle changes, sea-level-rise, and carbon cycle evolution. The ACME workflow, from simulation to data transfer, storage, analysis and publication will be presented. Current and planned methods to accelerate the workflow, including implementing run-time diagnostics, and implementing server-side analysis to avoid moving large datasets will be presented.

  1. A Distributed Prognostic Health Management Architecture

    NASA Technical Reports Server (NTRS)

    Bhaskar, Saha; Saha, Sankalita; Goebel, Kai

    2009-01-01

    This paper introduces a generic distributed prognostic health management (PHM) architecture with specific application to the electrical power systems domain. Current state-of-the-art PHM systems are mostly centralized in nature, where all the processing is reliant on a single processor. This can lead to loss of functionality in case of a crash of the central processor or monitor. Furthermore, with increases in the volume of sensor data as well as the complexity of algorithms, traditional centralized systems become unsuitable for successful deployment, and efficient distributed architectures are required. A distributed architecture though, is not effective unless there is an algorithmic framework to take advantage of its unique abilities. The health management paradigm envisaged here incorporates a heterogeneous set of system components monitored by a varied suite of sensors and a particle filtering (PF) framework that has the power and the flexibility to adapt to the different diagnostic and prognostic needs. Both the diagnostic and prognostic tasks are formulated as a particle filtering problem in order to explicitly represent and manage uncertainties; however, typically the complexity of the prognostic routine is higher than the computational power of one computational element ( CE). Individual CEs run diagnostic routines until the system variable being monitored crosses beyond a nominal threshold, upon which it coordinates with other networked CEs to run the prognostic routine in a distributed fashion. Implementation results from a network of distributed embedded devices monitoring a prototypical aircraft electrical power system are presented, where the CEs are Sun Microsystems Small Programmable Object Technology (SPOT) devices.

  2. The utility of an online diagnostic decision support system (Isabel) in general practice: a process evaluation.

    PubMed

    Henderson, Emily J; Rubin, Greg P

    2013-05-01

    To evaluate the utility of Isabel, an online diagnostic decision support system developed by Isabel Healthcare primarily for secondary medical care, in the general practice setting. Focus groups were conducted with clinicians to understand why and how they used the system. A modified online post-use survey asked practitioners about its impact on their decision-making. Normalization process theory (NPT) was used as a theoretical framework to determine whether the system could be incorporated into routine clinical practice. The system was introduced by NHS County Durham and Darlington in the UK in selected general practices as a three-month pilot. General practitioners and nurse practitioners who had access to Isabel as part of the Primary Care Trust's pilot. General practitioners' views, experiences and usage of the system. Seven general practices agreed to pilot Isabel. Two practices did not subsequently use it. The remaining five practices conducted searches on 16 patients. Post-use surveys (n = 10) indicated that Isabel had little impact on diagnostic decision-making. Focus group participants stated that, although the diagnoses produced by Isabel in general did not have an impact on their decision-making, they would find the tool useful if it were better tailored to the primary care setting. Our analysis concluded that normalization was not likely to occur in its current form. Isabel was of limited utility in this short pilot study and may need further modification for use in general practice.

  3. Novel Treponema pallidum Recombinant Antigens for Syphilis Diagnostics: Current Status and Future Prospects

    PubMed Central

    Kubanov, Aleksey; Runina, Anastassia

    2017-01-01

    The recombinant protein technology considerably promoted the development of rapid and accurate treponema-specific laboratory diagnostics of syphilis infection. For the last ten years, the immunodominant recombinant inner membrane lipoproteins are proved to be sensitive and specific antigens for syphilis screening. However, the development of an enlarged T. pallidum antigen panel for diagnostics of early and late syphilis and differentiation of syphilis stages or cured syphilis remains as actual goal of multidisciplinary expertise. Current review revealed novel recombinant antigens: surface-exposed proteins, adhesins, and periplasmic and flagellar proteins, which are promising candidates for the improved syphilis serological diagnostics. The opportunities and limitations of diagnostic usage of these antigens are discussed and the criteria for selection of optimal antigens panel summarized. PMID:28523273

  4. Validated methods for identifying tuberculosis patients in health administrative databases: systematic review.

    PubMed

    Ronald, L A; Ling, D I; FitzGerald, J M; Schwartzman, K; Bartlett-Esquilant, G; Boivin, J-F; Benedetti, A; Menzies, D

    2017-05-01

    An increasing number of studies are using health administrative databases for tuberculosis (TB) research. However, there are limitations to using such databases for identifying patients with TB. To summarise validated methods for identifying TB in health administrative databases. We conducted a systematic literature search in two databases (Ovid Medline and Embase, January 1980-January 2016). We limited the search to diagnostic accuracy studies assessing algorithms derived from drug prescription, International Classification of Diseases (ICD) diagnostic code and/or laboratory data for identifying patients with TB in health administrative databases. The search identified 2413 unique citations. Of the 40 full-text articles reviewed, we included 14 in our review. Algorithms and diagnostic accuracy outcomes to identify TB varied widely across studies, with positive predictive value ranging from 1.3% to 100% and sensitivity ranging from 20% to 100%. Diagnostic accuracy measures of algorithms using out-patient, in-patient and/or laboratory data to identify patients with TB in health administrative databases vary widely across studies. Use solely of ICD diagnostic codes to identify TB, particularly when using out-patient records, is likely to lead to incorrect estimates of case numbers, given the current limitations of ICD systems in coding TB.

  5. Access to diphtheria antitoxin for therapy and diagnostics.

    PubMed

    Both, L; White, J; Mandal, S; Efstratiou, A

    2014-06-19

    The most effective treatment for diphtheria is swift administration of diphtheria antitoxin (DAT) with conjunct antibiotic therapy. DAT is an equine immunoglobulin preparation and listed among the World Health Organization Essential Medicines. Essential Medicines should be available in functioning health systems at all times in adequate amounts, in appropriate dosage forms, with assured quality, and at prices individuals and the community can afford. However, DAT is in scarce supply and frequently unavailable to patients because of discontinued production in several countries, low economic viability, and high regulatory requirements for the safe manufacture of blood-derived products. DAT is also a cornerstone of diphtheria diagnostics but several diagnostic reference laboratories across the European Union (EU) and elsewhere routinely face problems in sourcing DAT for toxigenicity testing. Overall, global access to DAT for both therapeutic and diagnostic applications seems inadequate. Therefore--besides efforts to improve the current supply of DAT--accelerated research and development of alternatives including monoclonal antibodies for therapy and molecular-based methods for diagnostics are required. Given the rarity of the disease, it would be useful to organise a small stockpile centrally for all EU countries and to maintain an inventory of DAT availability within and between countries.

  6. Resource utilization in lung cancer diagnostic procedures: Current use and budget consequences.

    PubMed

    Brinkhof, Sander; Groen, Harry J M; Siesling, Sabine S; IJzerman, Maarten J

    2017-01-01

    The main objective of this study is to determine the current use of lung cancer diagnostic procedures in two large hospitals in the Netherlands, to explore deviations in guideline adherence between the hospitals, and to estimate the budget impact of the diagnostic work-up as well as the over- and underutilization. A state transition model for the diagnostic pathway for lung cancer patients was developed using existing clinical practice guidelines (CPG) combined with a systematic literature. In addition to the CPGs depicting current practice, diagnostic utilization was gathered in two large hospitals representing an academic tertiary care hospital and a large regional teaching hospital for patients, who were selected from the Netherlands cancer registry. The total population consisted of 376 patients with lung cancer. Not in all cases the guideline was followed, for instance in the usage of MR brain with stage III lung cancer patients (n = 70). The state-transition model predicts an average budget impact for the diagnostic pathway per patient estimated of € 2496 in the academic tertiary care hospital and € 2191 in the large regional teaching hospital. The adherence to the CPG's differed between hospitals, which questions the adherence to CPG's in general. Adherence to CPG's could lead to less costs in the diagnostic pathway for lung cancer patients.

  7. Design of a Neutron Temporal Diagnostic for measuring DD or DT burn histories at the NIF

    NASA Astrophysics Data System (ADS)

    Lahmann, B.; Frenje, J. A.; Sio, H.; Petrasso, R. D.; Bradley, D. K.; Le Pape, S.; MacKinnon, A. J.; Isumi, N.; Macphee, A.; Zayas, C.; Spears, B. K.; Hermann, H.; Hilsabeck, T. J.; Kilkenny, J. D.

    2015-11-01

    The DD or DT burn history in Inertial Confinement Fusion (ICF) implosions provides essential information about implosion performance and helps to constrain numerical modeling. The capability of measuring this burn history is thus important for the NIF in its pursuit of ignition. Currently, the Gamma Reaction History (GRH) diagnostic is the only system capable of measuring the burn history for DT implosions with yields greater than ~ 1e14. To complement GRH, a new NIF Neutron Temporal Diagnostic (NTD) is being designed for measuring the DD or DT burn history with yields greater than ~ 1e10. A traditional scintillator-based design and a pulse-dilation-based design are being considered. Using MCNPX simulations, both designs have been optimized, validated and contrasted for various types of implosions at the NIF. This work was supported in part by the U.S. DOE, LLNL and LLE.

  8. Array-based sensing using nanoparticles: an alternative approach for cancer diagnostics.

    PubMed

    Le, Ngoc D B; Yazdani, Mahdieh; Rotello, Vincent M

    2014-07-01

    Array-based sensing using nanoparticles (NPs) provides an attractive alternative to specific biomarker-focused strategies for cancer diagnosis. The physical and chemical properties of NPs provide both the recognition and transduction capabilities required for biosensing. Array-based sensors utilize a combined response from the interactions between sensors and analytes to generate a distinct pattern (fingerprint) for each analyte. These interactions can be the result of either the combination of multiple specific biomarker recognition (specific binding) or multiple selective binding responses, known as chemical nose sensing. The versatility of the latter array-based sensing using NPs can facilitate the development of new personalized diagnostic methodologies in cancer diagnostics, a necessary evolution in the current healthcare system to better provide personalized treatments. This review will describe the basic principle of array-based sensors, along with providing examples of both invasive and noninvasive samples used in cancer diagnosis.

  9. Commissioning of the synchrotron radiation protection system and beamlines frontends at NSLS-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S., E-mail: seletskiy@bnl.gov; Amundsen, C.; Choi, J.

    2016-07-27

    The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.

  10. Use of artificial intelligence in severe accident diagnosis for PWRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Zheng; Okrent, D.; Kastenberg, W.E.

    1995-12-31

    A combination approach of an expert system and neural networks is used to implement a prototype severe accident diagnostic system which would monitor the progression of the severe accident and provide necessary plant status information to assist the plant staff in accident management during the accident. The station blackout accident in a pressurized water reactor (PWR) is used as the study case. The current phase of research focus is on distinguishing different primary system failure modes and following the accident transient before and up to vessel breach.

  11. A failure management prototype: DR/Rx

    NASA Technical Reports Server (NTRS)

    Hammen, David G.; Baker, Carolyn G.; Kelly, Christine M.; Marsh, Christopher A.

    1991-01-01

    This failure management prototype performs failure diagnosis and recovery management of hierarchical, distributed systems. The prototype, which evolved from a series of previous prototypes following a spiral model for development, focuses on two functions: (1) the diagnostic reasoner (DR) performs integrated failure diagnosis in distributed systems; and (2) the recovery expert (Rx) develops plans to recover from the failure. Issues related to expert system prototype design and the previous history of this prototype are discussed. The architecture of the current prototype is described in terms of the knowledge representation and functionality of its components.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucia, M., E-mail: mlucia@pppl.gov; Kaita, R.; Majeski, R.

    The Materials Analysis and Particle Probe (MAPP) is a compact in vacuo surface science diagnostic, designed to provide in situ surface characterization of plasma facing components in a tokamak environment. MAPP has been implemented for operation on the Lithium Tokamak Experiment at Princeton Plasma Physics Laboratory (PPPL), where all control and analysis systems are currently under development for full remote operation. Control systems include vacuum management, instrument power, and translational/rotational probe drive. Analysis systems include onboard Langmuir probes and all components required for x-ray photoelectron spectroscopy, low-energy ion scattering spectroscopy, direct recoil spectroscopy, and thermal desorption spectroscopy surface analysis techniques.

  13. Remnant Geometric Hall Response in a Quantum Quench.

    PubMed

    Wilson, Justin H; Song, Justin C W; Refael, Gil

    2016-12-02

    Out-of-equilibrium systems can host phenomena that transcend the usual restrictions of equilibrium systems. Here, we unveil how out-of-equilibrium states, prepared via a quantum quench in a two-band system, can exhibit a nonzero Hall-type current-a remnant Hall response-even when the instantaneous Hamiltonian is time reversal symmetric (in contrast to equilibrium Hall currents). Interestingly, the remnant Hall response arises from the coherent dynamics of the wave function that retain a remnant of its quantum geometry postquench, and can be traced to processes beyond linear response. Quenches in two-band Dirac systems are natural venues for realizing remnant Hall currents, which exist when either mirror or time-reversal symmetry are broken (before or after the quench). Its long time persistence, sensitivity to symmetry breaking, and decoherence-type relaxation processes allow it to be used as a sensitive diagnostic of the complex out-of-equilibrium dynamics readily controlled and probed in cold-atomic optical lattice experiments.

  14. Using Fault Trees to Advance Understanding of Diagnostic Errors.

    PubMed

    Rogith, Deevakar; Iyengar, M Sriram; Singh, Hardeep

    2017-11-01

    Diagnostic errors annually affect at least 5% of adults in the outpatient setting in the United States. Formal analytic techniques are only infrequently used to understand them, in part because of the complexity of diagnostic processes and clinical work flows involved. In this article, diagnostic errors were modeled using fault tree analysis (FTA), a form of root cause analysis that has been successfully used in other high-complexity, high-risk contexts. How factors contributing to diagnostic errors can be systematically modeled by FTA to inform error understanding and error prevention is demonstrated. A team of three experts reviewed 10 published cases of diagnostic error and constructed fault trees. The fault trees were modeled according to currently available conceptual frameworks characterizing diagnostic error. The 10 trees were then synthesized into a single fault tree to identify common contributing factors and pathways leading to diagnostic error. FTA is a visual, structured, deductive approach that depicts the temporal sequence of events and their interactions in a formal logical hierarchy. The visual FTA enables easier understanding of causative processes and cognitive and system factors, as well as rapid identification of common pathways and interactions in a unified fashion. In addition, it enables calculation of empirical estimates for causative pathways. Thus, fault trees might provide a useful framework for both quantitative and qualitative analysis of diagnostic errors. Future directions include establishing validity and reliability by modeling a wider range of error cases, conducting quantitative evaluations, and undertaking deeper exploration of other FTA capabilities. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  15. A diagnostic expert system for aircraft generator control unit (GCU)

    NASA Astrophysics Data System (ADS)

    Ho, Ting-Long; Bayles, Robert A.; Havlicsek, Bruce L.

    The modular VSCF (variable-speed constant-frequency) generator families are described as using standard modules to reduce the maintenance cost and to improve the product's testability. A general diagnostic expert system shell that guides troubleshooting of modules or line replaceable units (LRUs) is introduced. An application of the diagnostic system to a particular LRU, the generator control unit (GCU) is reported. The approach to building the diagnostic expert system is first to capture general diagnostic strategy in an expert system shell. This shell can be easily applied to different devices or LRUs by writing rules to capture only additional device-specific diagnostic information from expert repair personnel. The diagnostic system has the necessary knowledge embedded in its programs and exhibits expertise to troubleshoot the GCU.

  16. Current trends in the use of liposomes for tumor targeting

    PubMed Central

    Deshpande, Pranali P; Biswas, Swati; Torchilin, Vladimir P

    2013-01-01

    The use of liposomes for drug delivery began early in the history of pharmaceutical nanocarriers. These nanosized, lipid bilayered vesicles have become popular as drug delivery systems owing to their efficiency, biocompatibility, nonimmunogenicity, enhanced solubility of chemotherapeutic agents and their ability to encapsulate a wide array of drugs. Passive and ligand-mediated active targeting promote tumor specificity with diminished adverse off-target effects. The current field of liposomes focuses on both clinical and diagnostic applications. Recent efforts have concentrated on the development of multifunctional liposomes that target cells and cellular organelles with a single delivery system. This review discusses the recent advances in liposome research in tumor targeting. PMID:23914966

  17. Windows on the human body--in vivo high-field magnetic resonance research and applications in medicine and psychology.

    PubMed

    Moser, Ewald; Meyerspeer, Martin; Fischmeister, Florian Ph S; Grabner, Günther; Bauer, Herbert; Trattnig, Siegfried

    2010-01-01

    Analogous to the evolution of biological sensor-systems, the progress in "medical sensor-systems", i.e., diagnostic procedures, is paradigmatically described. Outstanding highlights of this progress are magnetic resonance imaging (MRI) and spectroscopy (MRS), which enable non-invasive, in vivo acquisition of morphological, functional, and metabolic information from the human body with unsurpassed quality. Recent achievements in high and ultra-high field MR (at 3 and 7 Tesla) are described, and representative research applications in Medicine and Psychology in Austria are discussed. Finally, an overview of current and prospective research in multi-modal imaging, potential clinical applications, as well as current limitations and challenges is given.

  18. Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy Mcjunkin; Dennis C. Kunerth; Corrie Nichol

    2013-07-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less

  19. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.

    2014-02-18

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less

  20. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    NASA Astrophysics Data System (ADS)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.; Todorov, E.; Levesque, S.

    2014-02-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  1. Current state of biology and diagnosis of clonal mast cell diseases in adults.

    PubMed

    Alvarez-Twose, I; Morgado, J M; Sánchez-Muñoz, L; García-Montero, A; Mollejo, M; Orfao, A; Escribano, L

    2012-10-01

    Mastocytosis comprises a heterogeneous group of disorders characterized by the presence of clonal mast cells (MC) in organs such as skin, bone marrow (BM), and gastrointestinal tract, among other tissues. The clonal nature of the disease can be established in most adult patients by the demonstration of activating KIT mutations in their BM MC. When highly sensitive techniques capable of identifying cells present at very low frequencies in a sample are applied, BM MC from virtually all systemic mastocytosis patients display unique immunophenotypical features, particularly the aberrant expression of CD25. By contrast, large, multifocal BM MC aggregates (the only World Health Organization major criterion for systemic mastocytosis) are absent in a significant proportion of patients fulfilling at least three minor criteria for systemic mastocytosis, particularly in subjects studied at early stages of the disease with very low MC burden. Moreover, recent molecular and immunophenotypical investigations of BM MC from patients with indolent systemic mastocytosis have revealed a close association of some biological features (e.g., multilineage involvement of hematopoiesis by the KIT mutation and an immature mast cell immunophenotype) with an increased risk for disease progression. These observations support the fact that, although the current consensus diagnostic criteria for systemic mastocytosis have been a major advance for the diagnosis and classification of the disease, rationale usage of the most sensitive diagnostic techniques available nowadays is needed to improve the diagnosis, refine the classification, and reach objective prognostic stratification of adult mastocytosis. © 2012 Blackwell Publishing Ltd.

  2. [Digital electroencephalography in brain death diagnostics : Technical requirements and results of a survey on the compatibility with medical guidelines of digital EEG systems from providers in Germany].

    PubMed

    Walter, U; Noachtar, S; Hinrichs, H

    2018-02-01

    The guidelines of the German Medical Association and the German Society for Clinical Neurophysiology and Functional Imaging (DGKN) require a high procedural and technical standard for electroencephalography (EEG) as an ancillary method for diagnosing the irreversible cessation of brain function (brain death). Nowadays, digital EEG systems are increasingly being applied in hospitals. So far it is unclear to what extent the digital EEG systems currently marketed in Germany meet the guidelines for diagnosing brain death. In the present article, the technical und safety-related requirements for digital EEG systems and the EEG documentation for diagnosing brain death are described in detail. On behalf of the DGKN, the authors sent out a questionnaire to all identified distributors of digital EEG systems in Germany with respect to the following technical demands: repeated recording of the calibration signals during an ongoing EEG recording, repeated recording of all electrode impedances during an ongoing EEG recording, assessability of intrasystem noise and galvanic isolation of measurement earthing from earthing conductor (floating input). For 15 of the identified 20 different digital EEG systems the specifications were provided by the distributors (among them all distributors based in Germany). All of these EEG systems are provided with a galvanic isolation (floating input). The internal noise can be tested with all systems; however, some systems do not allow repeated recording of the calibration signals and/or the electrode impedances during an ongoing EEG recording. The majority but not all of the currently available digital EEG systems offered for clinical use are eligible for use in brain death diagnostics as per German guidelines.

  3. Epigenetics studies of fetal alcohol spectrum disorder: where are we now?

    PubMed

    Lussier, Alexandre A; Weinberg, Joanne; Kobor, Michael S

    2017-03-01

    Adverse in utero events can alter the development and function of numerous physiological systems, giving rise to lasting neurodevelopmental deficits. In particular, data have shown that prenatal alcohol exposure can reprogram neurobiological systems, altering developmental trajectories and resulting in increased vulnerability to adverse neurobiological, behavioral and health outcomes. Increasing evidence suggests that epigenetic mechanisms are potential mediators for the reprogramming of neurobiological systems, as they may provide a link between the genome, environmental conditions and neurodevelopmental outcomes. This review outlines the current state of epigenetic research in fetal alcohol spectrum disorder, highlighting the role of epigenetic mechanisms in the reprogramming of neurobiological systems by alcohol and as potential diagnostic tools for fetal alcohol spectrum disorder. We also present an assessment of the current limitations in studies of prenatal alcohol exposure, and highlight the future steps needed in the field.

  4. The Feasibility of Classifying Breast Masses Using a Computer-Assisted Diagnosis (CAD) System Based on Ultrasound Elastography and BI-RADS Lexicon.

    PubMed

    Fleury, Eduardo F C; Gianini, Ana Claudia; Marcomini, Karem; Oliveira, Vilmar

    2018-01-01

    To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted κ test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.

  5. Pathological diagnostic criterion of blood and lymphatic vessel invasion in colorectal cancer: a framework for developing an objective pathological diagnostic system using the Delphi method, from the Pathology Working Group of the Japanese Society for Cancer of the Colon and Rectum.

    PubMed

    Kojima, Motohiro; Shimazaki, Hideyuki; Iwaya, Keiichi; Kage, Masayoshi; Akiba, Jun; Ohkura, Yasuo; Horiguchi, Shinichiro; Shomori, Kohei; Kushima, Ryoji; Ajioka, Yoichi; Nomura, Shogo; Ochiai, Atsushi

    2013-07-01

    The goal of this study is to create an objective pathological diagnostic system for blood and lymphatic vessel invasion (BLI). 1450 surgically resected colorectal cancer specimens from eight hospitals were reviewed. Our first step was to compare the current practice of pathology assessment among eight hospitals. Then, H&E stained slides with or without histochemical/immunohistochemical staining were assessed by eight pathologists and concordance of BLI diagnosis was checked. In addition, histological findings associated with BLI having good concordance were reviewed. Based on these results, framework for developing diagnostic criterion was developed, using the Delphi method. The new criterion was evaluated using 40 colorectal cancer specimens. Frequency of BLI diagnoses, number of blocks obtained and stained for assessment of BLI varied among eight hospitals. Concordance was low for BLI diagnosis and was not any better when histochemical/immunohistochemical staining was provided. All histological findings associated with BLI from H&E staining were poor in agreement. However, observation of elastica-stained internal elastic membrane covering more than half of the circumference surrounding the tumour cluster as well as the presence of D2-40-stained endothelial cells covering more than half of the circumference surrounding the tumour cluster showed high concordance. Based on this observation, we developed a framework for pathological diagnostic criterion, using the Delphi method. This criterion was found to be useful in improving concordance of BLI diagnosis. A framework for pathological diagnostic criterion was developed by reviewing concordance and using the Delphi method. The criterion developed may serve as the basis for creating a standardised procedure for pathological diagnosis.

  6. Pathological diagnostic criterion of blood and lymphatic vessel invasion in colorectal cancer: a framework for developing an objective pathological diagnostic system using the Delphi method, from the Pathology Working Group of the Japanese Society for Cancer of the Colon and Rectum

    PubMed Central

    Kojima, Motohiro; Shimazaki, Hideyuki; Iwaya, Keiichi; Kage, Masayoshi; Akiba, Jun; Ohkura, Yasuo; Horiguchi, Shinichiro; Shomori, Kohei; Kushima, Ryoji; Ajioka, Yoichi; Nomura, Shogo; Ochiai, Atsushi

    2013-01-01

    Aims The goal of this study is to create an objective pathological diagnostic system for blood and lymphatic vessel invasion (BLI). Methods 1450 surgically resected colorectal cancer specimens from eight hospitals were reviewed. Our first step was to compare the current practice of pathology assessment among eight hospitals. Then, H&E stained slides with or without histochemical/immunohistochemical staining were assessed by eight pathologists and concordance of BLI diagnosis was checked. In addition, histological findings associated with BLI having good concordance were reviewed. Based on these results, framework for developing diagnostic criterion was developed, using the Delphi method. The new criterion was evaluated using 40 colorectal cancer specimens. Results Frequency of BLI diagnoses, number of blocks obtained and stained for assessment of BLI varied among eight hospitals. Concordance was low for BLI diagnosis and was not any better when histochemical/immunohistochemical staining was provided. All histological findings associated with BLI from H&E staining were poor in agreement. However, observation of elastica-stained internal elastic membrane covering more than half of the circumference surrounding the tumour cluster as well as the presence of D2-40-stained endothelial cells covering more than half of the circumference surrounding the tumour cluster showed high concordance. Based on this observation, we developed a framework for pathological diagnostic criterion, using the Delphi method. This criterion was found to be useful in improving concordance of BLI diagnosis. Conclusions A framework for pathological diagnostic criterion was developed by reviewing concordance and using the Delphi method. The criterion developed may serve as the basis for creating a standardised procedure for pathological diagnosis. PMID:23592799

  7. Unleashing Our Untapped Domestic Collection is the Key to Prevention

    DTIC Science & Technology

    2007-09-01

    Information Center (NCIC), Uniform Crime Reporting (UCR), and Integrated Automated Fingerprint Identification System (IAFIS) fingerprint ...The Blue Ocean Strategy Canvas , as described by Kim and Mauborgne, is an analytical framework that is both diagnostic and action oriented...The authors argue the value of a strategy canvas is its ability to capture the current state, provide an understanding of various factors impacting

  8. Design of a solar array simulator for the NASA EOS testbed

    NASA Technical Reports Server (NTRS)

    Butler, Steve J.; Sable, Dan M.; Lee, Fred C.; Cho, Bo H.

    1992-01-01

    The present spacecraft solar array simulator addresses both dc and ac characteristics as well as changes in illumination and temperature and performance degradation over the course of array service life. The computerized control system used allows simulation of a complete orbit cycle, in addition to automated diagnostics. The simulator is currently interfaced with the NASA EOS testbed.

  9. Zika fever.

    PubMed

    Martínez de Salazar, Pablo; Suy, Anna; Sánchez-Montalvá, Adrián; Rodó, Carlota; Salvador, Fernando; Molina, Israel

    2016-04-01

    Zika fever is an arboviral systemic disease that has recently become a public health challenge of global concern after its spread through the Americas. This review highlights the current understanding on Zika virus epidemiology, its routes of transmission, clinical manifestations, diagnostic tests, and the current management, prevention and control strategies. It also delves the association between Zika infection and complications, such as microencephaly or Guillem-Barré syndrome. Copyright © 2016 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  10. Grand challenges in bioengineered nanorobotics for cancer therapy.

    PubMed

    Lenaghan, Scott C; Wang, Yongzhong; Xi, Ning; Fukuda, Toshio; Tarn, Tzyhjong; Hamel, William R; Zhang, Mingjun

    2013-03-01

    One of the grand challenges currently facing engineering, life sciences, and medicine is the development of fully functional nanorobots capable of sensing, decision making, and actuation. These nanorobots may aid in cancer therapy, site-specific drug delivery, circulating diagnostics, advanced surgery, and tissue repair. In this paper, we will discuss, from a bioinspired perspective, the challenges currently facing nanorobotics, including core design, propulsion and power generation, sensing, actuation, control, decision making, and system integration. Using strategies inspired from microorganisms, we will discuss a potential bioengineered nanorobot for cancer therapy.

  11. Lithium-ion battery diagnostic and prognostic techniques

    DOEpatents

    Singh, Harmohan N.

    2009-11-03

    Embodiments provide a method and a system for determining cell imbalance condition of a multi-cell battery including a plurality of cell strings. To determine a cell imbalance condition, a charge current is applied to the battery and is monitored during charging. The charging time for each cell string is determined based on the monitor of the charge current. A charge time difference of any two cell strings in the battery is used to determine the cell imbalance condition by comparing with a predetermined acceptable charge time difference for the cell strings.

  12. Advances in Psychiatric Diagnosis: Past, Present, and Future.

    PubMed

    North, Carol S; Surís, Alina M

    2017-04-26

    This editorial examines controversies identified by the articles in this special issue, which explore psychopathology in the broad history of the classification of selected psychiatric disorders and syndromes over time through current American criteria. Psychiatric diagnosis has a long history of scientific investigation and application, with periods of rapid change, instability, and heated controversy associated with it. The articles in this issue examine the history of psychiatric nomenclature and explore current and future directions in psychiatric diagnosis through the various versions of accepted diagnostic criteria and accompanying research literature addressing the criteria. The articles seek to guide readers in appreciating the complexities of psychiatric diagnosis as the field of psychiatry pushes forward toward future advancements in diagnosis. Despite efforts of many scientists to advance a diagnostic classification system that incorporates neuroscience and genetics, it has been argued that it may be premature to attempt to move to a biologically-based classification system, because psychiatric disorders cannot yet be fully distinguished by any specific biological markers. For now, the symptom-based criteria that the field has been using continue to serve many essential purposes, including selection of the most effective treatment, communication about disease with colleagues, education about psychiatric illness, and support for ongoing research.

  13. Te and H_α Measurements on the HT-7 Tokamak: A Collaboration between the Fusion Research Center and the Institute of Plasma Physics

    NASA Astrophysics Data System (ADS)

    Winslow, D. L.; Carter, K. R.; Chatterjee, R.; Huang, H.; Phillips, P. E.; Rowan, W. L.; Kuang, G. L.; Li, J. G.; Luo, J. R.; Wan, B. N.; Wan, Y. X.; Xie, J. K.

    1998-11-01

    A team from the Fusion Research Center at the University of Texas at Austin visited the HT-7 Tokamak at the Institute of Plasma Physics at the Chinese Academy of Sciences in Hefei, Anhui, China to study the effects of lower hybrid current drive (LHCD) in the HT-7 plasma. HT-7(HT-7 Group, Fusion Energy 1996 Vol. 1, 685 (1997).) is a medium-sized (R = 1.22 m) tokamak with superconducting toroidal field coils and long--pulse capabilities utilizing LHCD to assist ohmic current drive. Core and edge diagnostics supported by a stand-alone data acquisition system were installed for the spring 1998 campaign. The diagnostics included an ECE radiometer which allows determination of both electron temperature profiles and fluctuation levels in the core plasma and an H_α array detector for measurement of turbulence in regions not easily accessible to probes. In addition, a reciprocating Langmuir probe system was developed for use on HT-7 and should be available for the next campaign. The effects of LHCD upon fluctuation levels in the plasma will be discussed.

  14. Multiple Sclerosis.

    PubMed

    Yamout, Bassem I; Alroughani, Raed

    2018-04-01

    Multiple sclerosis (MS) is a chronic central nervous system inflammatory disease of autoimmune etiology, mediated by activated T cells with evolving evidence of a significant contribution from B cells and cells of the innate immune system. The disease is thought to be due to a complex interaction between different genetic and environmental factors. The prevalence of MS is rising all over the world, due on one hand to earlier diagnosis and prolonged survival, and on the other to a true increase in incidence of the disease. The diagnosis of MS remains clinical despite recent advances in diagnostics and relies on demonstrating dissemination in space and time while excluding alternative diagnoses. The Mc Donald diagnostic criteria, with their recent 2017 revision, are currently widely accepted in the MS community. Although no cure is yet available, many disease-modifying therapies (DMTs) have shown different levels of efficacy in preventing relapses, accumulation of lesions on magnetic resonance imaging (MRI), and disability progression. Current treatment strategies include gradual escalation based on clinical and radiological criteria that determine treatment response, or initial induction with high efficacy DMTs especially in patients with an early aggressive course. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Portable, battery-operated, fluorescence field microscope for the developing world

    NASA Astrophysics Data System (ADS)

    Miller, Andrew R.; Davis, Gregory; Pierce, Mark; Oden, Z. Maria; Richards-Kortum, Rebecca

    2010-02-01

    In many areas of the world, current methods for diagnosis of infectious diseases such as malaria and tuberculosis involve microscopic evaluation of a patient specimen. Advances in fluorescence microscopy can improve diagnostic sensitivity and reduce time and expertise necessary to interpret diagnostic results. However, modern research-grade microscopes are neither available nor appropriate for use in many settings in the developing world. To address this need, we designed, fabricated, and tested a portable, battery-powered, bright field and fluorescence inverted field microscope, optimized for infrastructural constraints of the developing world. We characterized an initial prototype constructed with rapidprototyping techniques, which utilized low-cost, over-the-counter components such as a battery-powered LED flashlight as the light source. The microscope exhibited suitable spatial resolution (0.8 μm) in fluorescence mode to resolve M. tuberculosis bacilli. In bright field mode, malaria parasites were resolvable at 1000x magnification. The initial prototype cost 480 USD and we estimate that the microscope can be manufactured for 230 USD. While future studies are planned to evaluate ease-of-use and reliability, our current system serves as a proof of concept that combined fluorescence and bright field microscopy is possible in a low-cost and portable system.

  16. Integration of Stable Droplet Formation on a CD Microfluidic Device for Extreme Point of Care Applications

    NASA Astrophysics Data System (ADS)

    Ganesh, Shruthi Vatsyayani

    With the advent of microfluidic technologies for molecular diagnostics, a lot of emphasis has been placed on developing diagnostic tools for resource poor regions in the form of Extreme Point of Care devices. To ensure commercial viability of such a device there is a need to develop an accurate sample to answer system, which is robust, portable, isolated yet highly sensitive and cost effective. This need has been a driving force for research involving integration of different microsystems like droplet microfluidics, Compact-disc (CD)microfluidics along with sample preparation and detection modules on a single platform. This work attempts to develop a proof of concept prototype of one such device using existing CD microfluidics tools to generate stable droplets used in point of care diagnostics (POC diagnostics). Apart from using a fairly newer technique for droplet generation and stabilization, the work aims to develop this method focused towards diagnostics for rural healthcare. The motivation for this work is first described with an emphasis on the current need for diagnostic testing in rural health-care and the general guidelines prescribed by WHO for such a sample to answer system. Furthermore, a background on CD and droplet microfluidics is presented to understand the merits and de-merits of each system and the need for integrating the two. This phase of the thesis also includes different methods employed/demonstrated to generate droplets on a spinning platform. An overview on the detection platforms is also presented to understand the challenges involved in building an extreme point of care device. In the third phase of the thesis, general manufacturing techniques and materials used to accomplish this work is presented. Lastly, design trials for droplet generation is presented. The shortcomings of these trials are solved by investigating mechanisms pertaining to design modification and use of agarose based droplet generation to ensure a more robust sample processing method. This method is further characterized and compared with non-agarose based system and the results are analyzed. In conclusion, future prospects of this work are discussed in relation to extreme POC applications.

  17. Vascular Anomalies (Part I): Classification and Diagnostics of Vascular Anomalies.

    PubMed

    Sadick, Maliha; Müller-Wille, René; Wildgruber, Moritz; Wohlgemuth, Walter A

    2018-06-06

     Vascular anomalies are a diagnostic and therapeutic challenge. They require dedicated interdisciplinary management. Optimal patient care relies on integral medical evaluation and a classification system established by experts in the field, to provide a better understanding of these complex vascular entities.  A dedicated classification system according to the International Society for the Study of Vascular Anomalies (ISSVA) and the German Interdisciplinary Society of Vascular Anomalies (DiGGefA) is presented. The vast spectrum of diagnostic modalities, ranging from ultrasound with color Doppler, conventional X-ray, CT with 4 D imaging and MRI as well as catheter angiography for appropriate assessment is discussed.  Congenital vascular anomalies are comprised of vascular tumors, based on endothelial cell proliferation and vascular malformations with underlying mesenchymal and angiogenetic disorder. Vascular tumors tend to regress with patient's age, vascular malformations increase in size and are subdivided into capillary, venous, lymphatic, arterio-venous and combined malformations, depending on their dominant vasculature. According to their appearance, venous malformations are the most common representative of vascular anomalies (70 %), followed by lymphatic malformations (12 %), arterio-venous malformations (8 %), combined malformation syndromes (6 %) and capillary malformations (4 %).  The aim is to provide an overview of the current classification system and diagnostic characterization of vascular anomalies in order to facilitate interdisciplinary management of vascular anomalies.   · Vascular anomalies are comprised of vascular tumors and vascular malformations, both considered to be rare diseases.. · Appropriate treatment depends on correct classification and diagnosis of vascular anomalies, which is based on established national and international classification systems, recommendations and guidelines.. · In the classification, diagnosis and treatment of congenital vascular anomalies, radiology plays an integral part in patient management.. · Sadick M, Müller-Wille R, Wildgruber M et al. Vascular Anomalies (Part I): Classification and Diagnostics of Vascular Anomalies. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0620-8925. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Paper-based sample-to-answer molecular diagnostic platform for point-of-care diagnostics.

    PubMed

    Choi, Jane Ru; Tang, Ruihua; Wang, ShuQi; Wan Abas, Wan Abu Bakar; Pingguan-Murphy, Belinda; Xu, Feng

    2015-12-15

    Nucleic acid testing (NAT), as a molecular diagnostic technique, including nucleic acid extraction, amplification and detection, plays a fundamental role in medical diagnosis for timely medical treatment. However, current NAT technologies require relatively high-end instrumentation, skilled personnel, and are time-consuming. These drawbacks mean conventional NAT becomes impractical in many resource-limited disease-endemic settings, leading to an urgent need to develop a fast and portable NAT diagnostic tool. Paper-based devices are typically robust, cost-effective and user-friendly, holding a great potential for NAT at the point of care. In view of the escalating demand for the low cost diagnostic devices, we highlight the beneficial use of paper as a platform for NAT, the current state of its development, and the existing challenges preventing its widespread use. We suggest a strategy involving integrating all three steps of NAT into one single paper-based sample-to-answer diagnostic device for rapid medical diagnostics in the near future. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Indication for peritoneal biopsy in tuberculous peritonitis.

    PubMed

    Chow, Kai Ming; Chow, Viola Chi-Ying; Szeto, Cheuk Chun

    2003-06-01

    With the introduction of effective antituberculous chemotherapy, the clinical outcome of tuberculous peritonitis depends much on the diagnostic accuracy of this disease entity. This review summarizes the current state-of-the-art thinking regarding the protean manifestation and diagnostic modalities of this major infectious disease. This review was compiled after an extensive search of the current and historical literature, comprising 1,070 cases of tuberculous peritonitis. A number of important areas were highlighted, with emphasis on the diagnostic value and clinical impact of peritoneal biopsy. We believe an aggressive diagnostic approach, particularly with peritoneal biopsy, is warranted for the diagnosis and timely treatment of tuberculous peritonitis.

  20. AST Combustion Workshop: Diagnostics Working Group Report

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Hanson, Ronald K.

    1996-01-01

    A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value.

  1. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartlein, Rick; Hampton, Nigel; Perkel, Josh

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach asmore » a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.« less

  2. Diagnostic Principles of Peri-Implantitis: a Systematic Review and Guidelines for Peri-Implantitis Diagnosis Proposal.

    PubMed

    Ramanauskaite, Ausra; Juodzbalys, Gintaras

    2016-01-01

    To review and summarize the literature concerning peri-implantitis diagnostic parameters and to propose guidelines for peri-implantitis diagnosis. An electronic literature search was conducted of the MEDLINE (Ovid) and EMBASE databases for articles published between 2011 and 2016. Sequential screening at the title/abstract and full-text levels was performed. Systematic reviews/guidelines of consensus conferences proposing classification or suggesting diagnostic parameters for peri-implantitis in the English language were included. The review was recorded on PROSPERO system with the code CRD42016033287. The search resulted in 10 articles that met the inclusion criteria. Four were papers from consensus conferences, two recommended diagnostic guidelines, three proposed classification of peri-implantitis, and one suggested an index for implant success. The following parameters were suggested to be used for peri-implantitis diagnosis: pain, mobility, bleeding on probing, probing depth, suppuration/exudate, and radiographic bone loss. In all of the papers, different definitions of peri-implantitis or implant success, as well as different thresholds for the above mentioned clinical and radiographical parameters, were used. Current evidence rationale for the diagnosis of peri-implantitis and classification based on consecutive evaluation of soft-tissue conditions and the amount of bone loss were suggested. Currently there is no single uniform definition of peri-implantitis or the parameters that should be used. Rationale for diagnosis and prognosis of peri-implantitis as well as classification of the disease is proposed.

  3. Diagnosis of stinging insect allergy: utility of cellular in-vitro tests.

    PubMed

    Scherer, Kathrin; Bircher, Andreas J; Heijnen, Ingmar Afm

    2009-08-01

    Diagnosis of stinging insect allergy is based on a detailed history, venom skin tests, and detection of venom-specific IgE. As an additional diagnostic tool, basophil responsiveness to venom allergens has been shown to be helpful in selected patients. This review summarizes the current diagnostic procedures for stinging insect allergy and discusses the latest developments in cellular in-vitro tests. Cellular assays have been evaluated in patients with Hymenoptera venom allergy. The diagnostic performance of the cellular mediator release test is similar to that of the flow cytometric basophil activation test (BAT), but the BAT has been the most intensively studied. BAT offers the possibility to assess basophil reactivity to allergens in their natural environment and to simultaneously analyze surface marker expression and intracellular signaling. It has been demonstrated that BAT represents a valuable additional diagnostic tool in selected patients when used in combination with other well established tests. A major limitation is the current lack of unified, standardized protocols. Flow cytometry offers huge possibilities to enhance knowledge of basophil functions. The BAT may be used as an additional test to confirm the diagnosis of stinging insect allergy in selected patients, provided that it is performed by an experienced laboratory using a validated assay. Test results have to be interpreted by clinicians familiar with the methodological aspects. The utility of the BAT to confirm allergy diagnosis and to predict the risk of subsequent systemic reactions may be improved by combined analysis of multiple surface markers and intracellular signaling pathways.

  4. 3D "spectracoustic" system: a modular, tomographic, spectroscopic mapping imaging, non-invasive, diagnostic system for detection of small starting developing tumors like melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios

    2017-03-01

    This work led to a new method named 3D spectracoustic tomographic mapping imaging. The current and the future work is related to the fabrication of a combined acoustic microscopy transducer and infrared illumination probe permitting the simultaneous acquisition of the spectroscopic and the tomographic information. This probe provides with the capability of high fidelity and precision registered information from the combined modalities named spectracoustic information.

  5. Cutting Edge Methods for Non-Invasive Disease Diagnosis Using E-Tongue and E-Nose Devices

    PubMed Central

    Fitzgerald, Jessica

    2017-01-01

    Biomimetic cross-reactive sensor arrays (B-CRSAs) have been used to detect and diagnose a wide variety of diseases including metabolic disorders, mental health diseases, and cancer by analyzing both vapor and liquid patient samples. Technological advancements over the past decade have made these systems selective, sensitive, and affordable. To date, devices for non-invasive and accurate disease diagnosis have seen rapid improvement, suggesting a feasible alternative to current standards for medical diagnostics. This review provides an overview of the most recent B-CRSAs for diagnostics (also referred to electronic noses and tongues in the literature) and an outlook for future technological development. PMID:29215588

  6. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    NASA Astrophysics Data System (ADS)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  7. Towards real-time medical diagnostics using hyperspectral imaging technology

    NASA Astrophysics Data System (ADS)

    Bjorgan, Asgeir; Randeberg, Lise L.

    2015-07-01

    Hyperspectral imaging provides non-contact, high resolution spectral images which has a substantial diagnostic potential. This can be used for e.g. diagnosis and early detection of arthritis in finger joints. Processing speed is currently a limitation for clinical use of the technique. A real-time system for analysis and visualization using GPU processing and threaded CPU processing is presented. Images showing blood oxygenation, blood volume fraction and vessel enhanced images are among the data calculated in real-time. This study shows the potential of real-time processing in this context. A combination of the processing modules will be used in detection of arthritic finger joints from hyperspectral reflectance and transmittance data.

  8. Integrated material state awareness system with self-learning symbiotic diagnostic algorithms and models

    NASA Astrophysics Data System (ADS)

    Banerjee, Sourav; Liu, Lie; Liu, S. T.; Yuan, Fuh-Gwo; Beard, Shawn

    2011-04-01

    Materials State Awareness (MSA) goes beyond traditional NDE and SHM in its challenge to characterize the current state of material damage before the onset of macro-damage such as cracks. A highly reliable, minimally invasive system for MSA of Aerospace Structures, Naval structures as well as next generation space systems is critically needed. Development of such a system will require a reliable SHM system that can detect the onset of damage well before the flaw grows to a critical size. Therefore, it is important to develop an integrated SHM system that not only detects macroscale damages in the structures but also provides an early indication of flaw precursors and microdamages. The early warning for flaw precursors and their evolution provided by an SHM system can then be used to define remedial strategies before the structural damage leads to failure, and significantly improve the safety and reliability of the structures. Thus, in this article a preliminary concept of developing the Hybrid Distributed Sensor Network Integrated with Self-learning Symbiotic Diagnostic Algorithms and Models to accurately and reliably detect the precursors to damages that occur to the structure are discussed. Experiments conducted in a laboratory environment shows potential of the proposed technique.

  9. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    PubMed

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Advances in diagnostic and treatment modalities for intracranial tumors.

    PubMed

    Dickinson, P J

    2014-01-01

    Intracranial neoplasia is a common clinical condition in domestic companion animals, particularly in dogs. Application of advances in standard diagnostic and therapeutic modalities together with a broad interest in the development of novel translational therapeutic strategies in dogs has resulted in clinically relevant improvements in outcome for many canine patients. This review highlights the status of current diagnostic and therapeutic approaches to intracranial neoplasia and areas of novel treatment currently in development. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  11. Diagnostic of students' misconceptions using the Biological Concepts Instrument (BCI): A method for conducting an educational needs assessment

    PubMed Central

    Champagne Queloz, Annie; Klymkowsky, Michael W.; Stern, Elsbeth; Hafen, Ernst; Köhler, Katja

    2017-01-01

    Concept inventories, constructed based on an analysis of students’ thinking and their explanations of scientific situations, serve as diagnostics for identifying misconceptions and logical inconsistencies and provide data that can help direct curricular reforms. In the current project, we distributed the Biological Concepts Instrument (BCI) to 17-18-year-old students attending the highest track of the Swiss school system (Gymnasium). Students’ performances on many questions related to evolution, genetics, molecular properties and functions were diverse. Important common misunderstandings were identified in the areas of evolutionary processes, molecular properties and an appreciation of stochastic processes in biological systems. Our observations provide further evidence that the BCI is efficient in identifying specific areas where targeted instruction is required. Based on these observations we have initiated changes at several levels to reconsider how biological systems are presented to university biology studies with the goal of improving student’s foundational understanding. PMID:28493960

  12. High-level intuitive features (HLIFs) for intuitive skin lesion description.

    PubMed

    Amelard, Robert; Glaister, Jeffrey; Wong, Alexander; Clausi, David A

    2015-03-01

    A set of high-level intuitive features (HLIFs) is proposed to quantitatively describe melanoma in standard camera images. Melanoma is the deadliest form of skin cancer. With rising incidence rates and subjectivity in current clinical detection methods, there is a need for melanoma decision support systems. Feature extraction is a critical step in melanoma decision support systems. Existing feature sets for analyzing standard camera images are comprised of low-level features, which exist in high-dimensional feature spaces and limit the system's ability to convey intuitive diagnostic rationale. The proposed HLIFs were designed to model the ABCD criteria commonly used by dermatologists such that each HLIF represents a human-observable characteristic. As such, intuitive diagnostic rationale can be conveyed to the user. Experimental results show that concatenating the proposed HLIFs with a full low-level feature set increased classification accuracy, and that HLIFs were able to separate the data better than low-level features with statistical significance. An example of a graphical interface for providing intuitive rationale is given.

  13. Whole Exome Sequencing in Pediatric Neurology Patients: Clinical Implications and Estimated Cost Analysis.

    PubMed

    Nolan, Danielle; Carlson, Martha

    2016-06-01

    Genetic heterogeneity in neurologic disorders has been an obstacle to phenotype-based diagnostic testing. The authors hypothesized that information compiled via whole exome sequencing will improve clinical diagnosis and management of pediatric neurology patients. The authors performed a retrospective chart review of patients evaluated in the University of Michigan Pediatric Neurology clinic between 6/2011 and 6/2015. The authors recorded previous diagnostic testing, indications for whole exome sequencing, and whole exome sequencing results. Whole exome sequencing was recommended for 135 patients and obtained in 53 patients. Insurance barriers often precluded whole exome sequencing. The most common indication for whole exome sequencing was neurodevelopmental disorders. Whole exome sequencing improved the presumptive diagnostic rate in the patient cohort from 25% to 48%. Clinical implications included family planning, medication selection, and systemic investigation. Compared to current second tier testing, whole exome sequencing can result in lower long-term charges and more timely diagnosis. Overcoming barriers related to whole exome sequencing insurance authorization could allow for more efficient and fruitful diagnostic neurological evaluations. © The Author(s) 2016.

  14. SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

    NASA Astrophysics Data System (ADS)

    Raitt, W. John; Myers, Neil B.; Roberts, Jon A.; Thompson, D. C.

    1990-12-01

    An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

  15. Automated detection of retinal disease.

    PubMed

    Helmchen, Lorens A; Lehmann, Harold P; Abràmoff, Michael D

    2014-11-01

    Nearly 4 in 10 Americans with diabetes currently fail to undergo recommended annual retinal exams, resulting in tens of thousands of cases of blindness that could have been prevented. Advances in automated retinal disease detection could greatly reduce the burden of labor-intensive dilated retinal examinations by ophthalmologists and optometrists and deliver diagnostic services at lower cost. As the current availability of ophthalmologists and optometrists is inadequate to screen all patients at risk every year, automated screening systems deployed in primary care settings and even in patients' homes could fill the current gap in supply. Expanding screens to all patients at risk by switching to automated detection systems would in turn yield significantly higher rates of detecting and treating diabetic retinopathy per dilated retinal examination. Fewer diabetic patients would develop complications such as blindness, while ophthalmologists could focus on more complex cases.

  16. Informed consent for the diagnosis of brain death: a conceptual argument.

    PubMed

    Muramoto, Osamu

    2016-10-13

    This essay provides an ethical and conceptual argument for the use of informed consent prior to the diagnosis of brain death. It is meant to enable the family to make critical end-of-life decisions, particularly withdrawal of life support system and organ donation, before brain death is diagnosed, as opposed to the current practice of making such decisions after the diagnosis of death. The recent tragic case of a 13-year-old brain-dead patient in California who was maintained on a ventilator for over 2 years illustrates how such a consent would have made a crucial difference. Conceptual, philosophical, and ethical analysis. I first consider a conceptual justification for the use of consent for certain non-beneficial and unwanted medical diagnoses. I suggest that the diagnosis of brain death falls into this category for some patients. Because the diagnostic process of brain death lacks the transparency of traditional death determination, has a unique epistemic structure and a complex risk-benefit profile which differs markedly from case to case, and presents conflicts of interest for physicians and society, I argue that pre-diagnostic counseling and informed consent should be part of the diagnostic process. This approach can be termed as "allow cardiac death", whose parallel logic with "allow natural death" is discussed. I also discuss potential negative impacts on organ donation and health care cost from this proposal and offer possible mitigation. I show that the pre-diagnostic counseling can improve the possibility for well-thought-out decisions regarding organ donation and terminating life-support system in cases of hopeless prognosis. This approach differs conceptually from the pluralism of the definition of death, such as those in New Jersey and Japan, and it upholds the Uniform Determination of Death Act. My intention is not to provide an instant panacea for the ongoing impasse of the brain death debate, but to point to a novel conceptual ground for a more pragmatic, and more patient- and family-centered approach. By enabling the family to consent to or decline the diagnostic process of brain death, but not to choose the definition of death, it upholds the current legal definition of death.

  17. The Cloud Feedback Model Intercomparison Project (CFMIP) Diagnostic Codes Catalogue – metrics, diagnostics and methodologies to evaluate, understand and improve the representation of clouds and cloud feedbacks in climate models

    DOE PAGES

    Tsushima, Yoko; Brient, Florent; Klein, Stephen A.; ...

    2017-11-27

    The CFMIP Diagnostic Codes Catalogue assembles cloud metrics, diagnostics and methodologies, together with programs to diagnose them from general circulation model (GCM) outputs written by various members of the CFMIP community. This aims to facilitate use of the diagnostics by the wider community studying climate and climate change. Here, this paper describes the diagnostics and metrics which are currently in the catalogue, together with examples of their application to model evaluation studies and a summary of some of the insights these diagnostics have provided into the main shortcomings in current GCMs. Analysis of outputs from CFMIP and CMIP6 experiments willmore » also be facilitated by the sharing of diagnostic codes via this catalogue. Any code which implements diagnostics relevant to analysing clouds – including cloud–circulation interactions and the contribution of clouds to estimates of climate sensitivity in models – and which is documented in peer-reviewed studies, can be included in the catalogue. We very much welcome additional contributions to further support community analysis of CMIP6 outputs.« less

  18. The Cloud Feedback Model Intercomparison Project (CFMIP) Diagnostic Codes Catalogue – metrics, diagnostics and methodologies to evaluate, understand and improve the representation of clouds and cloud feedbacks in climate models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsushima, Yoko; Brient, Florent; Klein, Stephen A.

    The CFMIP Diagnostic Codes Catalogue assembles cloud metrics, diagnostics and methodologies, together with programs to diagnose them from general circulation model (GCM) outputs written by various members of the CFMIP community. This aims to facilitate use of the diagnostics by the wider community studying climate and climate change. Here, this paper describes the diagnostics and metrics which are currently in the catalogue, together with examples of their application to model evaluation studies and a summary of some of the insights these diagnostics have provided into the main shortcomings in current GCMs. Analysis of outputs from CFMIP and CMIP6 experiments willmore » also be facilitated by the sharing of diagnostic codes via this catalogue. Any code which implements diagnostics relevant to analysing clouds – including cloud–circulation interactions and the contribution of clouds to estimates of climate sensitivity in models – and which is documented in peer-reviewed studies, can be included in the catalogue. We very much welcome additional contributions to further support community analysis of CMIP6 outputs.« less

  19. Efficient Probabilistic Diagnostics for Electrical Power Systems

    NASA Technical Reports Server (NTRS)

    Mengshoel, Ole J.; Chavira, Mark; Cascio, Keith; Poll, Scott; Darwiche, Adnan; Uckun, Serdar

    2008-01-01

    We consider in this work the probabilistic approach to model-based diagnosis when applied to electrical power systems (EPSs). Our probabilistic approach is formally well-founded, as it based on Bayesian networks and arithmetic circuits. We investigate the diagnostic task known as fault isolation, and pay special attention to meeting two of the main challenges . model development and real-time reasoning . often associated with real-world application of model-based diagnosis technologies. To address the challenge of model development, we develop a systematic approach to representing electrical power systems as Bayesian networks, supported by an easy-to-use speci.cation language. To address the real-time reasoning challenge, we compile Bayesian networks into arithmetic circuits. Arithmetic circuit evaluation supports real-time diagnosis by being predictable and fast. In essence, we introduce a high-level EPS speci.cation language from which Bayesian networks that can diagnose multiple simultaneous failures are auto-generated, and we illustrate the feasibility of using arithmetic circuits, compiled from Bayesian networks, for real-time diagnosis on real-world EPSs of interest to NASA. The experimental system is a real-world EPS, namely the Advanced Diagnostic and Prognostic Testbed (ADAPT) located at the NASA Ames Research Center. In experiments with the ADAPT Bayesian network, which currently contains 503 discrete nodes and 579 edges, we .nd high diagnostic accuracy in scenarios where one to three faults, both in components and sensors, were inserted. The time taken to compute the most probable explanation using arithmetic circuits has a small mean of 0.2625 milliseconds and standard deviation of 0.2028 milliseconds. In experiments with data from ADAPT we also show that arithmetic circuit evaluation substantially outperforms joint tree propagation and variable elimination, two alternative algorithms for diagnosis using Bayesian network inference.

  20. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  1. Utilization of artificial intelligence techniques for the Space Station power system

    NASA Technical Reports Server (NTRS)

    Evatt, Thomas C.; Gholdston, Edward W.

    1988-01-01

    Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.

  2. A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST.

    PubMed

    Xiao, Shumei; Zang, Qing; Han, Xiaofeng; Wang, Tengfei; Yu, Jin; Zhao, Junyu

    2016-07-01

    Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

  3. Advances in Miniaturized Instruments for Genomics

    PubMed Central

    2014-01-01

    In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices. PMID:25114919

  4. Diagnostic workstation for digital hand atlas in bone age assessment

    NASA Astrophysics Data System (ADS)

    Cao, Fei; Huang, H. K.; Pietka, Ewa; Gilsanz, Vicente; Ominsky, Steven

    1998-06-01

    Bone age assessment by a radiological examination of a hand and wrist image is a procedure frequently performed in pediatric patients to evaluate growth disorders, determine growth potential in children and monitor therapy effects. The assessment method currently used in radiological diagnosis is based on atlas matching of the diagnosed hand image with the reference set of atlas patterns, which was developed in 1950s and is not fully applicable for children of today. We intent to implement a diagnostic workstation for creating a new reference set of clinically normal images which will serve as a digital atlas and can be used for a computer-assisted bone age assessment. In this paper, we present the initial data- collection and system setup phase of this five-year research program. We describe the system design, user interface implementation and software tool development for collection, visualization, management and processing of clinically normal hand and wrist images.

  5. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    NASA Astrophysics Data System (ADS)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  6. Lingual abscesses in three dogs.

    PubMed

    von Doernberg, M C; Peeters, M E; ter Haar, G; Kirpensteijn, J

    2008-08-01

    Lingual abscessation is a rare condition in dogs. Very little information is available on the diagnosis and treatment of lingual abscesses in the major surgical textbooks and current veterinary literature. The common clinical signs of lingual abscesses are macroglossia, hypersalivation and a reluctance to open the mouth, but these can vary depending on the time course of the disease and the location of the abscess. This article presents three cases of tongue abscess in the dog outlining treatment and outcomes. A thorough diagnostic work up, consisting of anamnesis, clinical and haematological examinations, oral inspection under sedation and the use of diagnostic imaging techniques should be mandatory before surgical exploration of the abscess. Surgery is followed by drainage and systemic antibiotics, complemented by systemic fluid support and pain management. Conservative management of lingual abscesses can be fatal. Sharp trauma from an unknown object is suspected to be the underlying cause for the abscesses in the present cases.

  7. The current and ideal state of anatomic pathology patient safety.

    PubMed

    Raab, Stephen Spencer

    2014-01-01

    An anatomic pathology diagnostic error may be secondary to a number of active and latent technical and/or cognitive components, which may occur anywhere along the total testing process in clinical and/or laboratory domains. For the pathologist interpretive steps of diagnosis, we examine Kahneman's framework of slow and fast thinking to explain different causes of error in precision (agreement) and in accuracy (truth). The pathologist cognitive diagnostic process involves image pattern recognition and a slow thinking error may be caused by the application of different rationally-constructed mental maps of image criteria/patterns by different pathologists. This type of error is partly related to a system failure in standardizing the application of these maps. A fast thinking error involves the flawed leap from image pattern to incorrect diagnosis. In the ideal state, anatomic pathology systems would target these cognitive error causes as well as the technical latent factors that lead to error.

  8. Development of advanced diagnostics for characterization of burning droplets in microgravity

    NASA Technical Reports Server (NTRS)

    Sankar, Subramanian; Buermann, Dale H.; Bachalo, William D.

    1995-01-01

    Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel droplet diameter, droplet regression rate, and the droplet internal temperature profiles or gradients at very high data rates in microgravity experiments.

  9. Diagnosis of multiple system atrophy

    PubMed Central

    Palma, Jose-Alberto; Norcliffe-Kaufmann, Lucy; Kaufmann, Horacio

    2017-01-01

    Multiple system atrophy (MSA) may be difficult to distinguish clinically from other disorders, particularly in the early stages of the disease. An autonomic-only presentation can be indistinguishable from pure autonomic failure. Patients presenting with parkinsonism may be misdiagnosed as having Parkinson disease. Patients presenting with the cerebellar phenotype of MSA can mimic other adult-onset ataxias due to alcohol, chemotherapeutic agents, lead, lithium, and toluene, or vitamin E deficiency, as well as paraneoplastic, autoimmune, or genetic ataxias. A careful medical history and meticulous neurological examination remain the cornerstone for the accurate diagnosis of MSA. Ancillary investigations are helpful to support the diagnosis, rule out potential mimics, and define therapeutic strategies. This review summarizes diagnostic investigations useful in the differential diagnosis of patients with suspected MSA. Currently used techniques include structural and functional brain imaging, cardiac sympathetic imaging, cardiovascular autonomic testing, olfactory testing, sleep study, urological evaluation, and dysphagia and cognitive assessments. Despite advances in the diagnostic tools for MSA in recent years and the availability of consensus criteria for clinical diagnosis, the diagnostic accuracy of MSA remains sub-optimal. As other diagnostic tools emerge, including skin biopsy, retinal biomarkers, blood and cerebrospinal fluid biomarkers, and advanced genetic testing, a more accurate and earlier recognition of MSA should be possible, even in the prodromal stages. This has important implications as misdiagnosis can result in inappropriate treatment, patient and family distress, and erroneous eligibility for clinical trials of disease-modifying drugs. PMID:29111419

  10. Current ante-mortem techniques for diagnosis of bovine tuberculosis.

    PubMed

    Bezos, Javier; Casal, Carmen; Romero, Beatriz; Schroeder, Bjoern; Hardegger, Roland; Raeber, Alex J; López, Lissette; Rueda, Paloma; Domínguez, Lucas

    2014-10-01

    Bovine tuberculosis (TB), mainly caused by Mycobacterium bovis, is a zoonotic disease with implications for Public Health and having an economic impact due to decreased production and limitations to the trade. Bovine TB is subjected to official eradication campaigns mainly based on a test and slaughter policy using diagnostic assays based on the cell-mediated immune response as the intradermal tuberculin test and the gamma-interferon (IFN-γ) assay. Moreover, several diagnostic assays based on the detection of specific antibodies (Abs) have been developed in the last few years with the aim of complementing the current diagnostic techniques in the near future. This review provides an overview of the current ante-mortem diagnostic tools for diagnosis of bovine TB regarding historical background, methodologies and sensitivity (Se) and specificity (Sp) obtained in previous studies under different epidemiological situations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Comprehensive Carrier Screening and Molecular Diagnostic Testing for Recessive Childhood Diseases

    PubMed Central

    Kingsmore, Stephen

    2012-01-01

    Of 7,028 disorders with suspected Mendelian inheritance, 1,139 are recessive and have an established molecular basis. Although individually uncommon, Mendelian diseases collectively account for ~20% of infant mortality and ~18% of pediatric hospitalizations. Molecular diagnostic testing is currently available for only ~300 recessive disorders. Preconception screening, together with genetic counseling of carriers, has resulted in remarkable declines in the incidence of several severe recessive diseases including Tay-Sachs disease and cystic fibrosis. However, extension of preconception screening and molecular diagnostic testing to most recessive disease genes has hitherto been impractical. Recently, we reported a preconception carrier screen / molecular diagnostic test for 448 recessive childhood diseases. The current status of this test is reviewed here. Currently, this reports analytical validity of the comprehensive carrier test. As the clinical validity and clinical utility in the contexts described is ascertained, this article will be updated. PMID:22872815

  12. A diagnostic interface for the ICOsahedral Non-hydrostatic (ICON) modelling framework based on the Modular Earth Submodel System (MESSy v2.50)

    NASA Astrophysics Data System (ADS)

    Kern, Bastian; Jöckel, Patrick

    2016-10-01

    Numerical climate and weather models have advanced to finer scales, accompanied by large amounts of output data. The model systems hit the input and output (I/O) bottleneck of modern high-performance computing (HPC) systems. We aim to apply diagnostic methods online during the model simulation instead of applying them as a post-processing step to written output data, to reduce the amount of I/O. To include diagnostic tools into the model system, we implemented a standardised, easy-to-use interface based on the Modular Earth Submodel System (MESSy) into the ICOsahedral Non-hydrostatic (ICON) modelling framework. The integration of the diagnostic interface into the model system is briefly described. Furthermore, we present a prototype implementation of an advanced online diagnostic tool for the aggregation of model data onto a user-defined regular coarse grid. This diagnostic tool will be used to reduce the amount of model output in future simulations. Performance tests of the interface and of two different diagnostic tools show, that the interface itself introduces no overhead in form of additional runtime to the model system. The diagnostic tools, however, have significant impact on the model system's runtime. This overhead strongly depends on the characteristics and implementation of the diagnostic tool. A diagnostic tool with high inter-process communication introduces large overhead, whereas the additional runtime of a diagnostic tool without inter-process communication is low. We briefly describe our efforts to reduce the additional runtime from the diagnostic tools, and present a brief analysis of memory consumption. Future work will focus on optimisation of the memory footprint and the I/O operations of the diagnostic interface.

  13. Molecular malaria diagnostics: A systematic review and meta-analysis.

    PubMed

    Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F

    2016-01-01

    Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.

  14. Novel uses of detonator diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, John R.; Wilde, Zakary Robert; Tasker, Douglas George

    A novel combination of diagnostics is being used to research the physics of detonator initiation. The explosive PETN (Pentaerythritol tetranitrate) commonly used in detonators, is also a piezo-electric material that, when sufficiently shocked, emits an electromagnetic field in the radio frequency (RF) range, along crystal fracture planes. In an effort to capture this RF signal, a new diagnostic was created. A copper foil, used as an RF antenna, was wrapped around a foam fixture encompassing a PETN pellet. Rogowski coils were used to obtain the change in current with respect to time (di/dt) the detonator circuit, in and polyvinylidene difluoridemore » (PVDF) stress sensors were used to capture shockwave arrival time. The goal of these experiments is to use these diagnostics to study the reaction response of a PETN pellet of known particle size to shock loading with various diagnostics including an antenna to capture RF emissions. Our hypothesis is that RF feedback may signify the rate of deflagration to detonation transition (DDT) or lack thereof. The new diagnostics and methods will be used to determine the timing of start of current, bridge burst, detonator breakout timing and RF generated from detonation. These data will be compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography, optical initiation and use of magnetic field sensors.« less

  15. Development of a molecular diagnostic test for Retinitis Pigmentosa in the Japanese population.

    PubMed

    Maeda, Akiko; Yoshida, Akiko; Kawai, Kanako; Arai, Yuki; Akiba, Ryutaro; Inaba, Akira; Takagi, Seiji; Fujiki, Ryoji; Hirami, Yasuhiko; Kurimoto, Yasuo; Ohara, Osamu; Takahashi, Masayo

    2018-05-21

    Retinitis Pigmentosa (RP) is the most common form of inherited retinal dystrophy caused by different genetic variants. More than 60 causative genes have been identified to date. The establishment of cost-effective molecular diagnostic tests with high sensitivity and specificity can be beneficial for patients and clinicians. Here, we developed a clinical diagnostic test for RP in the Japanese population. Evaluation of diagnostic technology, Prospective, Clinical and experimental study. A panel of 39 genes reported to cause RP in Japanese patients was established. Next generation sequence (NGS) technology was applied for the analyses of 94 probands with RP and RP-related diseases. After interpretation of detected genetic variants, molecular diagnosis based on a study of the genetic variants and a clinical phenotype was made by a multidisciplinary team including clinicians, researchers and genetic counselors. NGS analyses found 14,343 variants from 94 probands. Among them, 189 variants in 83 probands (88.3% of all cases) were selected as pathogenic variants and 64 probands (68.1%) have variants which can cause diseases. After the deliberation of these 64 cases, molecular diagnosis was made in 43 probands (45.7%). The final molecular diagnostic rate with the current system combining supplemental Sanger sequencing was 47.9% (45 of 94 cases). The RP panel provides the significant advantage of detecting genetic variants with a high molecular diagnostic rate. This type of race-specific high-throughput genotyping allows us to conduct a cost-effective and clinically useful genetic diagnostic test.

  16. Beyond Correctness: Development and Validation of Concept-Based Categorical Scoring Rubrics for Diagnostic Purposes

    ERIC Educational Resources Information Center

    Arieli-Attali, Meirav; Liu, Ying

    2016-01-01

    Diagnostic assessment approaches intend to provide fine-grained reports of what students know and can do, focusing on their areas of strengths and weaknesses. However, current application of such diagnostic approaches is limited by the scoring method for item responses; important diagnostic information, such as type of errors and strategy use is…

  17. Molecular aspects of development and regulation of endometriosis

    PubMed Central

    2014-01-01

    Endometriosis is a common and painful condition affecting women of reproductive age. While the underlying pathophysiology is still largely unknown, much advancement has been made in understanding the progression of the disease. In recent years, a great deal of research has focused on non-invasive diagnostic tools, such as biomarkers, as well as identification of potential therapeutic targets. In this article, we will review the etiology and cellular mechanisms associated with endometriosis as well as the current diagnostic tools and therapies. We will then discuss the more recent genomic and proteomic studies and how these data may guide development of novel diagnostics and therapeutics. The current diagnostic tools are invasive and current therapies primarily treat the symptoms of endometriosis. Optimally, the advancement of “-omic” data will facilitate the development of non-invasive diagnostic biomarkers as well as therapeutics that target the pathophysiology of the disease and halt, or even reverse, progression. However, the amount of data generated by these types of studies is vast and bioinformatics analysis, such as we present here, will be critical to identification of appropriate targets for further study. PMID:24927773

  18. A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses

    PubMed Central

    Priye, Aashish; Bird, Sara W.; Light, Yooli K.; Ball, Cameron S.; Negrete, Oscar A.; Meagher, Robert J.

    2017-01-01

    Current multiplexed diagnostics for Zika, dengue, and chikungunya viruses are situated outside the intersection of affordability, high performance, and suitability for use at the point-of-care in resource-limited settings. Consequently, insufficient diagnostic capabilities are a key limitation facing current Zika outbreak management strategies. Here we demonstrate highly sensitive and specific detection of Zika, chikungunya, and dengue viruses by coupling reverse-transcription loop-mediated isothermal amplification (RT-LAMP) with our recently developed quenching of unincorporated amplification signal reporters (QUASR) technique. We conduct reactions in a simple, inexpensive and portable “LAMP box” supplemented with a consumer class smartphone. The entire assembly can be powered by a 5 V USB source such as a USB power bank or solar panel. Our smartphone employs a novel algorithm utilizing chromaticity to analyze fluorescence signals, which improves the discrimination of positive/negative signals by 5-fold when compared to detection with traditional RGB intensity sensors or the naked eye. The ability to detect ZIKV directly from crude human sample matrices (blood, urine, and saliva) demonstrates our device’s utility for widespread clinical deployment. Together, these advances enable our system to host the key components necessary to expand the use of nucleic acid amplification-based detection assays towards point-of-care settings where they are needed most. PMID:28317856

  19. Peptidomics of urine and other biofluids for cancer diagnostics.

    PubMed

    Bauça, Josep Miquel; Martínez-Morillo, Eduardo; Diamandis, Eleftherios P

    2014-08-01

    Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers. © 2013 American Association for Clinical Chemistry.

  20. In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part II: Operational applications

    NASA Astrophysics Data System (ADS)

    Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik

    2016-08-01

    This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.

  1. Expanding the Taxonomy of the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD)

    PubMed Central

    Peck, Christopher C.; Goulet, Jean-Paul; Lobbezoo, Frank; Schiffman, Eric L.; Alstergren, Per; Anderson, Gary C.; de Leeuw, Reny; Jensen, Rigmor; Michelotti, Ambra; Ohrbach, Richard; Petersson, Arne; List, Thomas

    2014-01-01

    Background There is a need to expand the current temporomandibular disorder (TMD) classification to include less common, but clinically important disorders. The immediate aim was to develop a consensus-based classification system and associated diagnostic criteria that have clinical and research utility for less common TMDs. The long-term aim was to establish a foundation, vis-à-vis this classification system, that will stimulate data collection, validity testing, and further criteria refinement. Methods A working group [members of the International RDC/TMD Consortium Network of the International Association for Dental Research (IADR), members of the Orofacial Pain Special Interest Group (SIG) of the International Association for the Study of Pain (IASP), and members from other professional societies] reviewed disorders for inclusion based on clinical significance, the availability of plausible diagnostic criteria, and the ability to operationalize and study the criteria. The disorders were derived from the literature when possible and based on expert opinion as necessary. The expanded TMD taxonomy was presented for feedback at international meetings. Results Of 56 disorders considered, 37 were included in the expanded taxonomy and were placed into the following four categories: temporomandibular joint disorders, masticatory muscle disorders, headache disorders, and disorders affecting associated structures. Those excluded were extremely uncommon, lacking operationalized diagnostic criteria, not clearly related to TMDs, or not sufficiently distinct from disorders already included within the taxonomy. Conclusions The expanded TMD taxonomy offers an integrated approach to clinical diagnosis and provides a framework for further research to operationalize and test the proposed taxonomy and diagnostic criteria. PMID:24443898

  2. Expanding the taxonomy of the diagnostic criteria for temporomandibular disorders.

    PubMed

    Peck, C C; Goulet, J-P; Lobbezoo, F; Schiffman, E L; Alstergren, P; Anderson, G C; de Leeuw, R; Jensen, R; Michelotti, A; Ohrbach, R; Petersson, A; List, T

    2014-01-01

    There is a need to expand the current temporomandibular disorders' (TMDs) classification to include less common but clinically important disorders. The immediate aim was to develop a consensus-based classification system and associated diagnostic criteria that have clinical and research utility for less common TMDs. The long-term aim was to establish a foundation, vis-à-vis this classification system, that will stimulate data collection, validity testing and further criteria refinement. A working group [members of the International RDC/TMD Consortium Network of the International Association for Dental Research (IADR), members of the Orofacial Pain Special Interest Group (SIG) of the International Association for the Study of Pain (IASP), and members from other professional societies] reviewed disorders for inclusion based on clinical significance, the availability of plausible diagnostic criteria and the ability to operationalise and study the criteria. The disorders were derived from the literature when possible and based on expert opinion as necessary. The expanded TMDs taxonomy was presented for feedback at international meetings. Of 56 disorders considered, 37 were included in the expanded taxonomy and were placed into the following four categories: temporomandibular joint disorders, masticatory muscle disorders, headache disorders and disorders affecting associated structures. Those excluded were extremely uncommon, lacking operationalised diagnostic criteria, not clearly related to TMDs, or not sufficiently distinct from disorders already included within the taxonomy. The expanded TMDs taxonomy offers an integrated approach to clinical diagnosis and provides a framework for further research to operationalise and test the proposed taxonomy and diagnostic criteria. © 2014 John Wiley & Sons Ltd.

  3. Conversion disorder: a problematic diagnosis.

    PubMed

    Nicholson, Timothy R J; Stone, Jon; Kanaan, Richard A A

    2011-11-01

    The diagnosis of conversion disorder is problematic. Since doctors have conceptually and practically differentiated the symptoms from neurological ('organic') disease it has been presumed to be a psychological disorder, but the psychological mechanism, and how this differs from feigning (conscious simulation), has remained elusive. Although misdiagnosis of neurological disease as conversion disorder is uncommon, it remains a concern for clinicians, particularly for psychiatrists who may be unaware of the positive ways in which neurologists can exclude organic disease. The diagnosis is anomalous in psychiatry in that current diagnostic systems require that feigning is excluded and that the symptoms can be explained psychologically. In practice, feigning is very difficult to either disprove or prove, and a psychological explanation cannot always be found. Studies of childhood and adult psychological precipitants have tended to support the relevance of stressful life events prior to symptom onset at the group level but they are not found in a substantial proportion of cases. These problems highlight serious theoretical and practical issues not just for the current diagnostic systems but for the concept of the disorder itself. Psychology, physiology and functional imaging techniques have been used in attempts to elucidate the neurobiology of conversion disorder and to differentiate it from feigning, but while intriguing results are emerging they can only be considered preliminary. Such work looks to a future that could refine our understanding of the disorder. However, until that time, the formal diagnostic requirement for associated psychological stressors and the exclusion of feigning are of limited clinical value. Simplified criteria are suggested which will also encourage cooperation between neurology and psychiatry in the management of these patients.

  4. Mass spectrometry based proteomics profiling as diagnostic tool in oncology: current status and future perspective.

    PubMed

    Findeisen, Peter; Neumaier, Michael

    2009-01-01

    Proteomics analysis has been heralded as a novel tool for identifying new and specific biomarkers that may improve diagnosis and monitoring of various disease states. Recent years have brought a number of proteomics profiling technologies. Although proteomics profiling has resulted in the detection of disease-associated differences and modification of proteins, current proteomics technologies display certain limitations that are hampering the introduction of these new technologies into clinical laboratory diagnostics and routine applications. In this review, we summarize current advances in mass spectrometry based biomarker discovery. The promises and challenges of this new technology are discussed with particular emphasis on diagnostic perspectives of mass-spectrometry based proteomics profiling for malignant diseases.

  5. Potential Role of Circulating MiR-21 in the Diagnosis and Prognosis of Digestive System Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Yin, Chengqiang; Zhou, Xiaoying; Dang, Yini; Yan, Jin; Zhang, Guoxin

    2015-12-01

    Recent evidences indicate that circulating microRNAs (miRNAs) exhibit aberrant expression in the plasma of patients suffering from cancer compared to normal individuals, suggesting that it may be a useful noninvasion diagnostic method. MiR-21 plays crucial roles in carcinogenesis and can be served as a biomarker for the detection of various cancers. Therefore, the aim of this meta-analysis is to assess the potential role of miR-21 for digestive system cancer. By searching the PubMed, Embase, and Web of Science for publications concerning the diagnostic value of miR-21 for digestive system cancer, total of 23 publications were included in this meta-analysis. Receiver operating characteristic curves (ROC) were used to check the overall test performance. For prognostic meta-analysis, pooled hazard ratios (HRs) of circulating miR-21 for survival were calculated. Totally 23 eligible publications were included in this meta-analysis (15 articles for diagnosis and 8 articles for prognosis). For diagnostic meta-analysis, the summary estimates revealed that the pooled sensitivity and specificity were 0.76 (95% CI = 0.70-0.82) and 0.84 (95% CI = 0.78-0.89). Besides, the area under the summary ROC curve (AUC) is 0.87. For prognostic meta-analysis, the pooled HR of higher miR-21 expression in circulation was 1.94 (95% CI = 0.99-3.82, P = 0.055), which indicated higher miR-21 expression could be likely to predict poorer survival in digestive system cancer. The subgroup analysis implied the higher expression of miR-21 was correlated with worse overall survival in the Asian population in digestive system cancer (HR = 2.41, 95% CI = 1.21-4.77, P = 0.012). The current evidence suggests circulating miR-21 may be suitable to be a diagnostic and prognostic biomarker for digestive system cancer in the Asians.

  6. BETA (Bitter Electromagnet Testing Apparatus) Design and Testing

    NASA Astrophysics Data System (ADS)

    Bates, Evan; Birmingham, William; Rivera, William; Romero-Talamas, Carlos

    2016-10-01

    BETA is a 1T water cooled Bitter-type magnetic system that has been designed and constructed at the Dusty Plasma Laboratory of the University of Maryland, Baltimore County to serve as a prototype of a scaled 10T version. Currently the system is undergoing magnetic, thermal and mechanical testing to ensure safe operating conditions and to prove analytical design optimizations. These magnets will function as experimental tools for future dusty plasma based and collaborative experiments. An overview of design methods used for building a custom made Bitter magnet with user defined experimental constraints is reviewed. The three main design methods consist of minimizing the following: ohmic power, peak conductor temperatures, and stresses induced by Lorentz forces. We will also discuss the design of BETA which includes: the magnet core, pressure vessel, cooling system, power storage bank, high powered switching system, diagnostics with safety cutoff feedback, and data acquisition (DAQ)/magnet control Matlab code. Furthermore, we present experimental data from diagnostics for validation of our analytical preliminary design methodologies and finite element analysis calculations. BETA will contribute to the knowledge necessary to finalize the 10 T magnet design.

  7. Exploitation of high resolution beam spectroscopy diagnostics on MAST

    NASA Astrophysics Data System (ADS)

    Michael, Clive; Debock, Maarten; Conway, Neil; Akers, Rob; Appel, Lynton; Field, Anthony; Walsh, Mike; Wisse, Marco

    2009-11-01

    Recent developments in beam spectroscopy on MAST, including CXRS, MSE and a pilot FIDA system have revealed new information about phenomena such as ITBs, MHD instabilities, transport and fast particle physics. For example, ITBs in the ion temperature and toroidal rotation have been observed with the 64ch CXRS system, while reverse-shear q profiles have been observed with the recently commissioned 35ch MSE system. Thus, the synergy of these diagnostics helps us to understand, among other things, the role of magnetic and rotational shear on ITBs. MSE measurements have also helped to understand MHD phenomena such as locked modes (characterized by changes in toroidal momentum, revealed by CXRS), sawteeth, and internal reconnection events. Finally, the temporal/spatial resolution and SNR of the MSE system have been exploited. Interesting results include the detection of low frequency (˜2kHz) magnetic field fluctuations, characterization of the radial structure of higher frequency (<100kHz) broadband and coherent density (BES) fluctuations, and the identification of short scale length features (˜1.8cm) in the current profile near the edge pedestal.

  8. Intelligent Engine Systems: Bearing System

    NASA Technical Reports Server (NTRS)

    Singh, Arnant P.

    2008-01-01

    The overall requirements necessary for sensing bearing distress and the related criteria to select a particular rotating sensor were established during the phase I. The current phase II efforts performed studies to evaluate the Robustness and Durability Enhancement of the rotating sensors, and to design, and develop the Built-in Telemetry System concepts for an aircraft engine differential sump. A generic test vehicle that can test the proposed bearing diagnostic system was designed, developed, and built. The Timken Company, who also assisted with testing the GE concept of using rotating sensors for the differential bearing diagnostics during previous phase, was selected as a subcontractor to assist General Electric (GE) for the design, and procurement of the test vehicle. A purchase order was prepared to define the different sub-tasks, and deliverables for this task. The University of Akron was selected to provide the necessary support for installing, and integrating the test vehicle with their newly designed test facility capable of simulating the operating environment for the planned testing. The planned testing with good and damaged bearings will be on hold pending further continuation of this effort during next phase.

  9. Recent Advances in Targeted, Self-Assembling Nanoparticles to Address Vascular Damage Due to Atherosclerosis

    PubMed Central

    Chung, Eun Ji; Tirrell, Matthew

    2016-01-01

    Self-assembling nanoparticles functionalized with targeting moieties have significant potential for atherosclerosis nanomedicine. While self-assembly allows for easy construction (and degradation) of nanoparticles with therapeutic or diagnostic functionality, or both, the targeting agent can direct them to a specific molecular marker within a given stage of the disease. Therefore, supramolecular nanoparticles have been investigated in the last decade as molecular imaging agents or explored as nanocarriers that can decrease the systemic toxicity of drugs by producing accumulation predominantly in specific tissues of interest. In this review, we first describe the pathogenesis of atherosclerosis and the damage caused to vascular tissue, as well as the current diagnostic and treatment options. Then we provide an overview of targeted strategies using self-assembling nanoparticles and include liposomes, high density lipoproteins, protein cages, micelles, proticles, and perfluorocarbon nanoparticles. Finally, we elaborate on and provide an overview of current challenges, limitations, and future applications for personalized medicine in the context of atherosclerosis of self-assembling nanoparticles. PMID:26085109

  10. Nanotechnology in diagnosis and treatment of coronary artery disease.

    PubMed

    Karimi, Mahdi; Zare, Hossein; Bakhshian Nik, Amirala; Yazdani, Narges; Hamrang, Mohammad; Mohamed, Elmira; Sahandi Zangabad, Parham; Moosavi Basri, Seyed Masoud; Bakhtiari, Leila; Hamblin, Michael R

    2016-01-01

    Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD.

  11. Nanotechnology in diagnosis and treatment of coronary artery disease

    PubMed Central

    Karimi, Mahdi; Zare, Hossein; Bakhshian Nik, Amirala; Yazdani, Narges; Hamrang, Mohammad; Mohamed, Elmira; Sahandi Zangabad, Parham; Moosavi Basri, Seyed Masoud; Bakhtiari, Leila; Hamblin, Michael R

    2016-01-01

    Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD. PMID:26906471

  12. Diagnostic for a high-repetition rate electron photo-gun and first measurements

    NASA Astrophysics Data System (ADS)

    Filippetto, D.; Doolittle, L.; Huang, G.; Norum, E.; Portmann, G.; Qian, H.; Sannibale, F.

    2015-05-01

    The APEX electron source at LBNL combines the high-repetition-rate with the high beam brightness typical of photoguns, delivering low emittance electron pulses at MHz frequency. Proving the high beam quality of the beam is an essential step for the success of the experiment, opening the doors of the high average power to brightness-hungry applications as X-Ray FELs, MHz ultrafast electron diffraction etc.. As first step, a complete characterization of the beam parameters is foreseen at the Gun beam energy of 750 keV. Diagnostics for low and high current measurements have been installed and tested, and measurements of cathode lifetime and thermal emittance in a RF environment with mA current performed. The recent installation of a double slit system, a deflecting cavity and a high precision spectrometer, allow the exploration of the full 6D phase space. Here we discuss the present layout of the machine and future upgrades, showing the latest results at low and high repetition rate, together with the tools and techniques used.

  13. Culture-independent diagnostics for health security

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doggett, Norman A.; Mukundan, Harshini; Lefkowitz, Elliot J.

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamosmore » National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification–based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. Furthermore, this article combines information from the literature review and the insights obtained at the workshop.« less

  14. Culture-independent diagnostics for health security

    DOE PAGES

    Doggett, Norman A.; Mukundan, Harshini; Lefkowitz, Elliot J.; ...

    2016-06-17

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamosmore » National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification–based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. Furthermore, this article combines information from the literature review and the insights obtained at the workshop.« less

  15. Culture-Independent Diagnostics for Health Security.

    PubMed

    Doggett, Norman A; Mukundan, Harshini; Lefkowitz, Elliot J; Slezak, Tom R; Chain, Patrick S; Morse, Stephen; Anderson, Kevin; Hodge, David R; Pillai, Segaran

    2016-01-01

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamos National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification-based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. This article combines information from the literature review and the insights obtained at the workshop.

  16. Propulsion Controls and Diagnostics Research at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay

    2007-01-01

    With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. Also the propulsion systems required to enable the National Aeronautics and Space Administration (NASA) Vision for Space Exploration in an affordable manner will need to have high reliability, safety and autonomous operation capability. The Controls and Dynamics Branch (CDB) at NASA Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of Intelligent Propulsion Systems. This paper describes the current activities of the CDB under the NASA Aeronautics Research and Exploration Systems Missions. The programmatic structure of the CDB activities is described along with a brief overview of each of the CDB tasks including research objectives, technical challenges, and recent accomplishments. These tasks include active control of propulsion system components, intelligent propulsion diagnostics and control for reliable fault identification and accommodation, distributed engine control, and investigations into unsteady propulsion systems.

  17. Population-based prevalence of smoking in psychiatric inpatients: a focus on acute suicide risk and major diagnostic groups.

    PubMed

    Lineberry, Timothy W; Allen, Josiah D; Nash, Jessica; Galardy, Christine W

    2009-01-01

    The aim of the study was to define the extent of current and lifetime smoking by diagnostic groups and suicide risk as reason for admission in a geographically defined psychiatric inpatient cohort. The study used a population-based retrospective chart review. Smoking status and discharge diagnoses for Olmsted County, Minnesota, inpatients aged 18 to 65 admitted for psychiatric hospitalization in 2004 and 2005 were abstracted from the electronic medical record. Diagnostic groups were compared to each other using chi(2) tests and Fisher exact test to analyze smoking status within the inpatient sample with significance defined as P

  18. How to Use the DX SYSTEM of Diagnostic Testing. Methodology Project.

    ERIC Educational Resources Information Center

    McArthur, David; Cabello, Beverly

    The DX SYSTEM of Diagnostic Testing is an easy-to-use computerized system for developing and administering diagnostic tests. A diagnostic test measures a student's mastery of a specific domain (skill or content area). It examines the necessary subskills hierarchically from the most to the least complex. The DX SYSTEM features tailored testing with…

  19. Multi-scale Modeling of the Cardiovascular System: Disease Development, Progression, and Clinical Intervention.

    PubMed

    Zhang, Yanhang; Barocas, Victor H; Berceli, Scott A; Clancy, Colleen E; Eckmann, David M; Garbey, Marc; Kassab, Ghassan S; Lochner, Donna R; McCulloch, Andrew D; Tran-Son-Tay, Roger; Trayanova, Natalia A

    2016-09-01

    Cardiovascular diseases (CVDs) are the leading cause of death in the western world. With the current development of clinical diagnostics to more accurately measure the extent and specifics of CVDs, a laudable goal is a better understanding of the structure-function relation in the cardiovascular system. Much of this fundamental understanding comes from the development and study of models that integrate biology, medicine, imaging, and biomechanics. Information from these models provides guidance for developing diagnostics, and implementation of these diagnostics to the clinical setting, in turn, provides data for refining the models. In this review, we introduce multi-scale and multi-physical models for understanding disease development, progression, and designing clinical interventions. We begin with multi-scale models of cardiac electrophysiology and mechanics for diagnosis, clinical decision support, personalized and precision medicine in cardiology with examples in arrhythmia and heart failure. We then introduce computational models of vasculature mechanics and associated mechanical forces for understanding vascular disease progression, designing clinical interventions, and elucidating mechanisms that underlie diverse vascular conditions. We conclude with a discussion of barriers that must be overcome to provide enhanced insights, predictions, and decisions in pre-clinical and clinical applications.

  20. Multi-scale Modeling of the Cardiovascular System: Disease Development, Progression, and Clinical Intervention

    PubMed Central

    Zhang, Yanhang; Barocas, Victor H.; Berceli, Scott A.; Clancy, Colleen E.; Eckmann, David M.; Garbey, Marc; Kassab, Ghassan S.; Lochner, Donna R.; McCulloch, Andrew D.; Tran-Son-Tay, Roger; Trayanova, Natalia A.

    2016-01-01

    Cardiovascular diseases (CVDs) are the leading cause of death in the western world. With the current development of clinical diagnostics to more accurately measure the extent and specifics of CVDs, a laudable goal is a better understanding of the structure-function relation in the cardiovascular system. Much of this fundamental understanding comes from the development and study of models that integrate biology, medicine, imaging, and biomechanics. Information from these models provides guidance for developing diagnostics, and implementation of these diagnostics to the clinical setting, in turn, provides data for refining the models. In this review, we introduce multi-scale and multi-physical models for understanding disease development, progression, and designing clinical interventions. We begin with multi-scale models of cardiac electrophysiology and mechanics for diagnosis, clinical decision support, personalized and precision medicine in cardiology with examples in arrhythmia and heart failure. We then introduce computational models of vasculature mechanics and associated mechanical forces for understanding vascular disease progression, designing clinical interventions, and elucidating mechanisms that underlie diverse vascular conditions. We conclude with a discussion of barriers that must be overcome to provide enhanced insights, predictions, and decisions in pre-clinical and clinical applications. PMID:27138523

  1. Development of Simple Designs of Multitip Probe Diagnostic Systems for RF Plasma Characterization

    PubMed Central

    Naz, M. Y.; Shukrullah, S.; Ghaffar, A.; Rehman, N. U.

    2014-01-01

    Multitip probes are very useful diagnostics for analyzing and controlling the physical phenomena occurring in low temperature discharge plasmas. However, DC biased probes often fail to perform well in processing plasmas. The objective of the work was to deduce simple designs of DC biased multitip probes for parametric study of radio frequency plasmas. For this purpose, symmetric double probe, asymmetric double probe, and symmetric triple probe diagnostic systems and their driving circuits were designed and tested in an inductively coupled plasma (ICP) generated by a 13.56 MHz radio frequency (RF) source. Using I-V characteristics of these probes, electron temperature, electron number density, and ion saturation current was measured as a function of input power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density for increasing input RF power whilst a decreasing trend was evident in these parameters when measured against filling gas pressure. In addition, the electron energy probability function (EEPF) was also studied by using an asymmetric double probe. These studies confirmed the non-Maxwellian nature of the EEPF and the presence of two groups of the energetic electrons at low filling gas pressures. PMID:24683326

  2. Introduction of the Bethesda System to Mainland China with a Web-based tutorial.

    PubMed

    Yuan, Qin; Chang, Alexander Russell; Ng, Ho Keung

    2003-01-01

    To validate the use of a Web-based tutorial to introduce the Bethesda System (TBS) to Mainland Chinese laboratories. Digitized color images of the diagnostic features in 20 Pap smears were displayed on a Web page. Participants were asked to give each smear a diagnosis using the reporting nomenclature employed in their laboratory or one that was familiar to them. This was followed by teaching images of each smear accompanied by text in English and Chinese that highlighted important features for making a diagnosis using TBS. Participants then reviewed the 20 original Pap smears and rendered a diagnosis using TBS. Pathologists and cytotechnologists at 17 laboratories located in 10 cities completed the exercise. The average diagnostic accuracy for the 20 Pap smears before and after the tutorial was 76% and 88%, respectively. Web-based tutorials can be used for disseminating cytologic information to widely dispersed laboratories in China and help enhance the practice of cytology, currently an underutilized diagnostic technique. However, such difficulties as lack of Internet connections in the laboratory, outdated computers and a lack of interest in cytology need to be overcome to ensure success.

  3. Efficient fault diagnosis of helicopter gearboxes

    NASA Technical Reports Server (NTRS)

    Chin, H.; Danai, K.; Lewicki, D. G.

    1993-01-01

    Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.

  4. Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery.

    PubMed

    Petrovic, Stanislava; Bogavac-Stanojevic, Natasa; Lakic, Dragana; Peco-Antic, Amira; Vulicevic, Irena; Ivanisevic, Ivana; Kotur-Stevuljevic, Jelena; Jelic-Ivanovic, Zorana

    2015-01-01

    Acute kidney injury (AKI) is significant problem in children with congenital heart disease (CHD) who undergo cardiac surgery. The economic impact of a biomarker-based diagnostic strategy for AKI in pediatric populations undergoing CHD surgery is unknown. The aim of this study was to perform the cost effectiveness analysis of using serum cystatin C (sCysC), urine neutrophil gelatinase-associated lipocalin (uNGAL) and urine liver fatty acid-binding protein (uL-FABP) for the diagnosis of AKI in children after cardiac surgery compared with current diagnostic method (monitoring of serum creatinine (sCr) level). We developed a decision analytical model to estimate incremental cost-effectiveness of different biomarker-based diagnostic strategies compared to current diagnostic strategy. The Markov model was created to compare the lifetime cost associated with using of sCysC, uNGAL, uL-FABP with monitoring of sCr level for the diagnosis of AKI. The utility measurement included in the analysis was quality-adjusted life years (QALY). The results of the analysis are presented as the incremental cost-effectiveness ratio (ICER). Analysed biomarker-based diagnostic strategies for AKI were cost-effective compared to current diagnostic method. However, uNGAL and sCys C strategies yielded higher costs and lower effectiveness compared to uL-FABP strategy. uL-FABP added 1.43 QALY compared to current diagnostic method at an additional cost of $8521.87 per patient. Therefore, ICER for uL-FABP compared to sCr was $5959.35/QALY. Our results suggest that the use of uL-FABP would represent cost effective strategy for early diagnosis of AKI in children after cardiac surgery.

  5. A Systematic Review of the Diagnostic Stability of Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Woolfenden, Sue; Sarkozy, Vanessa; Ridley, Greta; Williams, Katrina

    2012-01-01

    There is debate in the current literature regarding the permanence of an Autism Spectrum Disorder (ASD) diagnosis. We undertook a systematic review of the diagnostic stability of ASD to summarise current evidence. A comprehensive search strategy was used to identify studies. Participants were children with ASD. Risk of bias was assessed by…

  6. Current Issues in the Diagnosis of Attention Deficit Hyperactivity Disorder, Oppositional Defiant Disorder, and Conduct Disorder

    PubMed Central

    Frick, Paul J.; Nigg, Joel T.

    2015-01-01

    This review evaluates the diagnostic criteria for three of the most common disorders for which children and adolescents are referred for mental health treatment: attention deficit hyperactivity disorder (ADHD), oppositional defiant disorder (ODD), and conduct disorder (CD). Although research supports the validity and clinical utility of these disorders, several issues are highlighted that could enhance the current diagnostic criteria. For ADHD, defining the core features of the disorder and its fit with other disorders, enhancing the validity of the criteria through the lifespan, considering alternative ways to form subtypes of the disorder, and modifying the age-of-onset criterion are discussed relative to the current diagnostic criteria. For ODD, eliminating the exclusionary criteria of CD, recognizing important symptom domains within the disorder, and using the cross-situational pervasiveness of the disorder as an index of severity are highlighted as important issues for improving classification. Finally, for CD, enhancing the current subtypes related to age of onset and integrating callous-unemotional traits into the diagnostic criteria are identified as key issues for improving classification. PMID:22035245

  7. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  8. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  9. 40 CFR 86.1806-01 - On-board diagnostics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...

  10. Epigenetics studies of fetal alcohol spectrum disorder: where are we now?

    PubMed Central

    Lussier, Alexandre A; Weinberg, Joanne; Kobor, Michael S

    2017-01-01

    Adverse in utero events can alter the development and function of numerous physiological systems, giving rise to lasting neurodevelopmental deficits. In particular, data have shown that prenatal alcohol exposure can reprogram neurobiological systems, altering developmental trajectories and resulting in increased vulnerability to adverse neurobiological, behavioral and health outcomes. Increasing evidence suggests that epigenetic mechanisms are potential mediators for the reprogramming of neurobiological systems, as they may provide a link between the genome, environmental conditions and neurodevelopmental outcomes. This review outlines the current state of epigenetic research in fetal alcohol spectrum disorder, highlighting the role of epigenetic mechanisms in the reprogramming of neurobiological systems by alcohol and as potential diagnostic tools for fetal alcohol spectrum disorder. We also present an assessment of the current limitations in studies of prenatal alcohol exposure, and highlight the future steps needed in the field. PMID:28234026

  11. Immunophenotyping in systemic mastocytosis diagnosis: 'CD25 positive' alone is more informative than the 'CD25 and/or CD2' WHO criterion.

    PubMed

    Morgado, José Mário T; Sánchez-Muñoz, Laura; Teodósio, Cristina G; Jara-Acevedo, Maria; Alvarez-Twose, Iván; Matito, Almudena; Fernández-Nuñez, Elisa; García-Montero, Andrés; Orfao, Alberto; Escribano, Luís

    2012-04-01

    Aberrant expression of CD2 and/or CD25 by bone marrow, peripheral blood or other extracutaneous tissue mast cells is currently used as a minor World Health Organization diagnostic criterion for systemic mastocytosis. However, the diagnostic utility of CD2 versus CD25 expression by mast cells has not been prospectively evaluated in a large series of systemic mastocytosis. Here we evaluate the sensitivity and specificity of CD2 versus CD25 expression in the diagnosis of systemic mastocytosis. Mast cells from a total of 886 bone marrow and 153 other non-bone marrow extracutaneous tissue samples were analysed by multiparameter flow cytometry following the guidelines of the Spanish Network on Mastocytosis at two different laboratories. The 'CD25+ and/or CD2+ bone marrow mast cells' World Health Organization criterion showed an overall sensitivity of 100% with 99.0% specificity for the diagnosis of systemic mastocytosis whereas CD25 expression alone presented a similar sensitivity (100%) with a slightly higher specificity (99.2%). Inclusion of CD2 did not improve the sensitivity of the test and it decreased its specificity. In tissues other than bone marrow, the mast cell phenotypic criterion revealed to be less sensitive. In summary, CD2 expression does not contribute to improve the diagnosis of systemic mastocytosis when compared with aberrant CD25 expression alone, which supports the need to update and replace the minor World Health Organization 'CD25+ and/or CD2+' mast cell phenotypic diagnostic criterion by a major criterion based exclusively on CD25 expression.

  12. Neurosurgical confocal endomicroscopy: A review of contrast agents, confocal systems, and future imaging modalities

    PubMed Central

    Zehri, Aqib H.; Ramey, Wyatt; Georges, Joseph F.; Mooney, Michael A.; Martirosyan, Nikolay L.; Preul, Mark C.; Nakaji, Peter

    2014-01-01

    Background: The clinical application of fluorescent contrast agents (fluorescein, indocyanine green, and aminolevulinic acid) with intraoperative microscopy has led to advances in intraoperative brain tumor imaging. Their properties, mechanism of action, history of use, and safety are analyzed in this report along with a review of current laser scanning confocal endomicroscopy systems. Additional imaging modalities with potential neurosurgical utility are also analyzed. Methods: A comprehensive literature search was performed utilizing PubMed and key words: In vivo confocal microscopy, confocal endomicroscopy, fluorescence imaging, in vivo diagnostics/neoplasm, in vivo molecular imaging, and optical imaging. Articles were reviewed that discussed clinically available fluorophores in neurosurgery, confocal endomicroscopy instrumentation, confocal microscopy systems, and intraoperative cancer diagnostics. Results: Current clinically available fluorescent contrast agents have specific properties that provide microscopic delineation of tumors when imaged with laser scanning confocal endomicroscopes. Other imaging modalities such as coherent anti-Stokes Raman scattering (CARS) microscopy, confocal reflectance microscopy, fluorescent lifetime imaging (FLIM), two-photon microscopy, and second harmonic generation may also have potential in neurosurgical applications. Conclusion: In addition to guiding tumor resection, intraoperative fluorescence and microscopy have the potential to facilitate tumor identification and complement frozen section analysis during surgery by providing real-time histological assessment. Further research, including clinical trials, is necessary to test the efficacy of fluorescent contrast agents and optical imaging instrumentation in order to establish their role in neurosurgery. PMID:24872922

  13. High Current Systems for HyperV and PLX Plasma Railguns

    NASA Astrophysics Data System (ADS)

    Brockington, S.; Case, A.; Messer, S.; Elton, R.; Witherspoon, F. D.

    2011-10-01

    HyperV is developing gas fed, pulsed, plasma railgun accelerators for PLX and other high momentum plasma applications. The present 2.5 cm square-bore plasma railgun forms plasma armatures from high density neutral gas (argon), preionizes it electrothermally, and accelerates the armature with 30 cm long parallel-plate railgun electrodes driven by a pulse forming network (PFN). Recent experiments have successfully formed and accelerated plasma armatures of ~4 mg at 40 km/s, with PFN currents of ~400 kA. In order to further increase railgun performance to the PLX design goal of 8 mg at 50 km/s, the PFN was upgraded to support currents of up to ~750 kA. A high voltage, high current linear array spark-gap switch and flexible, low-inductance transmission line were designed and constructed to handle the increased current load. We will describe these systems and present initial performance data from high current operation of the plasma rail gun from spectroscopy, interferometry, and imaging systems as well as pressure, magnetic field, and optical diagnostics. High current performance of railgun bore materials for electrodes and insulators will also be discussed as well as plans for upcoming experimentation with advanced materials. Supported by the U.S. DOE Joint Program in HEDLP.

  14. ICNIRP Statement on Diagnostic Devices Using Non-ionizing Radiation: Existing Regulations and Potential Health Risks.

    PubMed

    2017-03-01

    Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media.

  15. ICNIRP Statement on Diagnostic Devices Using Non-ionizing Radiation: Existing Regulations and Potential Health Risks

    PubMed Central

    2017-01-01

    Abstract Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media. PMID:28121732

  16. Miniature Biometric Sensor Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Terrier, Douglas; Clayton, Ronald; Hanson, Andrea; Cooper, Tommy; Downs, Meghan; Flint, Stephanie; Reyna, Baraquiel; Simon, Cory; Wilt, Grier

    2015-01-01

    Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

  17. Selection of examples in case-based computer-aided decision systems

    PubMed Central

    Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.

    2013-01-01

    Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606

  18. DDS: The Dental Diagnostic Simulation System.

    ERIC Educational Resources Information Center

    Tira, Daniel E.

    The Dental Diagnostic Simulation (DDS) System provides an alternative to simulation systems which represent diagnostic case studies of relatively limited scope. It may be used to generate simulated case studies in all of the dental specialty areas with case materials progressing through the gamut of the diagnostic process. The generation of a…

  19. Understanding missed opportunities for more timely diagnosis of cancer in symptomatic patients after presentation

    PubMed Central

    Lyratzopoulos, G; Vedsted, P; Singh, H

    2015-01-01

    The diagnosis of cancer is a complex, multi-step process. In this paper, we highlight factors involved in missed opportunities to diagnose cancer more promptly in symptomatic patients and discuss responsible mechanisms and potential strategies to shorten intervals from presentation to diagnosis. Missed opportunities are instances in which post-hoc judgement indicates that alternative decisions or actions could have led to more timely diagnosis. They can occur in any of the three phases of the diagnostic process (initial diagnostic assessment; diagnostic test performance and interpretation; and diagnostic follow-up and coordination) and can involve patient, doctor/care team, and health-care system factors, often in combination. In this perspective article, we consider epidemiological ‘signals' suggestive of missed opportunities and draw on evidence from retrospective case reviews of cancer patient cohorts to summarise factors that contribute to missed opportunities. Multi-disciplinary research targeting such factors is important to shorten diagnostic intervals post presentation. Insights from the fields of organisational and cognitive psychology, human factors science and informatics can be extremely valuable in this emerging research agenda. We provide a conceptual foundation for the development of future interventions to minimise the occurrence of missed opportunities in cancer diagnosis, enriching current approaches that chiefly focus on clinical decision support or on widening access to investigations. PMID:25734393

  20. An update on the use of cerebrospinal fluid analysis as a diagnostic tool in multiple sclerosis.

    PubMed

    Gastaldi, Matteo; Zardini, Elisabetta; Franciotta, Diego

    2017-01-01

    Intrathecal B-lymphocyte activation is a hallmark of multiple sclerosis (MS), a multi-factorial inflammatory-demyelinating disease of the central nervous system. Such activation has a counterpart in the cerebrospinal fluid (CSF) oligoclonal IgG bands (OCB), whose diagnostic role in MS has been downgraded within the current McDonald's criteria. With a theoretico-practical approach, the authors review the physiopathological basis of the CSF dynamics, and the state-of-the-art of routine CSF analysis and CSF biomarkers in MS. Areas covered: The authors discuss pros and cons of CSF analysis, including critical evaluations of both well-established, and promising diagnostic and prognostic laboratory tools. New acquisitions on the CSF and cerebral interstitial fluid dynamics are also presented. The authors searched the PubMed database for English-language articles reported between January 2010 and June 2016, using the key words 'multiple sclerosis', 'cerebrospinal fluid', 'oligoclonal bands'. Reference lists of relevant articles were scanned for additional studies. Expert commentary: The availability of performing high-quality, routine CSF tests in specialized laboratories, the emerging potential of novel CSF biomarkers, and the trend for early treatments should induce a reappraisal of CSF analysis for diagnostic and prognostic purposes in MS. Further procedural and methodological improvements seem to be necessary in both research and translational diagnostic CSF settings.

Top