NASA Astrophysics Data System (ADS)
Okafor, A. C.; Natarajan, S.
2007-03-01
Aging aircraft are prone to corrosion damage and fatigue cracks in riveted lap joints of fuselage skin panels. This can cause catastrophic failure if not detected and repaired. Hence detection of corrosion damage and monitoring its effect on structural integrity are essential. This paper presents multifrequency eddy current (EC) inspection of corrosion damage and machined material loss defect in clad A1 2024-T3 riveted lap joints and its effect on fatigue life. Results of eddy current inspection, corrosion product removal and fatigue testing are presented.
Procedure for Automated Eddy Current Crack Detection in Thin Titanium Plates
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.
2012-01-01
This procedure provides the detailed instructions for conducting Eddy Current (EC) inspections of thin (5-30 mils) titanium membranes with thickness and material properties typical of the development of Ultra-Lightweight diaphragm Tanks Technology (ULTT). The inspection focuses on the detection of part-through, surface breaking fatigue cracks with depths between approximately 0.002" and 0.007" and aspect ratios (a/c) of 0.2-1.0 using an automated eddy current scanning and image processing technique.
Amplitude-independent flaw length determination using differential eddy current
NASA Astrophysics Data System (ADS)
Shell, E.
2013-01-01
Military engine component manufacturers typically specify the eddy current (EC) inspection requirements as a crack length or depth with the assumption that the cracks in both the test specimens and inspected component are of a similar fixed aspect ratio. However, differential EC response amplitude is dependent on the area of the crack face, not the length or depth. Additionally, due to complex stresses, in-service cracks do not always grow in the assumed manner. It would be advantageous to use more of the information contained in the EC data to better determine the full profile of cracks independent of the fixed aspect ratio amplitude response curve. A specimen with narrow width notches is used to mimic cracks of varying aspect ratios in a controllable manner. The specimen notches have aspect ratios that vary from 1:1 to 10:1. Analysis routines have been developed using the shape of the EC response signals that can determine the length of a surface flaw of common orientations without use of the amplitude of the signal or any supporting traditional probability of detection basis. Combined with the relationship between signal amplitude and area, the depth of the flaw can also be calculated.
Evaluation of eddy current and magnetic techniques for inspecting rebars in bridge barrier rails
NASA Astrophysics Data System (ADS)
Lo, C. C. H.; Nakagawa, N.
2013-01-01
This paper reports on a feasibility study of using eddy current (EC) and magnetic flux leakage (MFL) methods to detect corrosion damage in rebars that anchor concrete barrier rails to the road deck of bridge structures. EC and MFL measurements were carried out on standalone rebars with and without artificial defects of 25% and 50% material loss, using a commercial EC-based rebar locator and a MFL system that was developed using giant magnetoresistance sensors to detect leakage fluxes from the defects. Both techniques can readily detect the defects at a distance of 2.5″ (63.5 mm). The amplitudes of the EC and MFL signals vary monotonically with the amount of material loss, indicating the potential of using the techniques to quantify material loss of standalone rebars.
NASA Astrophysics Data System (ADS)
Schulze, Martin H.; Heuer, Henning
2012-04-01
Carbon fiber based materials are used in many lightweight applications in aeronautical, automotive, machine and civil engineering application. By the increasing automation in the production process of CFRP laminates a manual optical inspection of each resin transfer molding (RTM) layer is not practicable. Due to the limitation to surface inspection, the quality parameters of multilayer 3 dimensional materials cannot be observed by optical systems. The Imaging Eddy- Current (EC) NDT is the only suitable inspection method for non-resin materials in the textile state that allows an inspection of surface and hidden layers in parallel. The HF-ECI method has the capability to measure layer displacements (misaligned angle orientations) and gap sizes in a multilayer carbon fiber structure. EC technique uses the variation of the electrical conductivity of carbon based materials to obtain material properties. Beside the determination of textural parameters like layer orientation and gap sizes between rovings, the detection of foreign polymer particles, fuzzy balls or visualization of undulations can be done by the method. For all of these typical parameters an imaging classification process chain based on a high resolving directional ECimaging device named EddyCus® MPECS and a 2D-FFT with adapted preprocessing algorithms are developed.
NASA Technical Reports Server (NTRS)
Piascik, Robert S.; Prosser, William H.
2011-01-01
The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the findings and recommendations from the NESC assessment.
NASA Technical Reports Server (NTRS)
Piascik, Robert S.; Prosser, William H.
2011-01-01
The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the Appendices to the main report.
NASA Astrophysics Data System (ADS)
Safdernejad, Morteza S.; Karpenko, Oleksii; Ye, Chaofeng; Udpa, Lalita; Udpa, Satish
2016-02-01
The advent of Giant Magneto-Resistive (GMR) technology permits development of novel highly sensitive array probes for Eddy Current (EC) inspection of multi-layer riveted structures. Multi-frequency GMR measurements with different EC pene-tration depths show promise for detection of bottom layer notches at fastener sites. However, the distortion of the induced magnetic field due to flaws is dominated by the strong fastener signal, which makes defect detection and classification a challenging prob-lem. This issue is more pronounced for ferromagnetic fasteners that concentrate most of the magnetic flux. In the present work, a novel multi-frequency mixing algorithm is proposed to suppress rivet signal response and enhance defect detection capability of the GMR array probe. The algorithm is baseline-free and does not require any assumptions about the sample geometry being inspected. Fastener signal suppression is based upon the random sample consensus (RANSAC) method, which iteratively estimates parameters of a mathematical model from a set of observed data with outliers. Bottom layer defects at fastener site are simulated as EDM notches of different length. Performance of the proposed multi-frequency mixing approach is evaluated on finite element data and experimental GMR measurements obtained with unidirectional planar current excitation. Initial results are promising demonstrating the feasibility of the approach.
The Safety Course Design and Operations of Composite Overwrapped Pressure Vessels (COPV)
NASA Technical Reports Server (NTRS)
Saulsberry, Regor; Prosser, William
2015-01-01
Following a Commercial Launch Vehicle On-Pad COPV (Composite Overwrapped Pressure Vessels) failure, a request was received by the NESC (NASA Engineering and Safety Center) June 14, 2014. An assessment was approved July 10, 2014, to develop and assess the capability of scanning eddy current (EC) nondestructive evaluation (NDE) methods for mapping thickness and inspection for flaws. Current methods could not identify thickness reduction from necking and critical flaw detection was not possible with conventional dye penetrant (PT) methods, so sensitive EC scanning techniques were needed. Developmental methods existed, but had not been fully developed, nor had the requisite capability assessment (i.e., a POD (Probability of Detection) study) been performed.
Nonlinear, non-stationary image processing technique for eddy current NDE
NASA Astrophysics Data System (ADS)
Yang, Guang; Dib, Gerges; Kim, Jaejoon; Zhang, Lu; Xin, Junjun; Udpa, Lalita
2012-05-01
Automatic analysis of eddy current (EC) data has facilitated the analysis of large volumes of data generated in the inspection of steam generator tubes in nuclear power plants. The traditional procedure for analysis of EC data includes data calibration, pre-processing, region of interest (ROI) detection, feature extraction and classification. Accurate ROI detection has been enhanced by pre-processing, which involves reducing noise and other undesirable components as well as enhancing defect indications in the raw measurement. This paper presents the Hilbert-Huang Transform (HHT) for feature extraction and support vector machine (SVM) for classification. The performance is shown to significantly better than the existing rule based classification approach used in industry.
Risk based meat hygiene--examples on food chain information and visual meat inspection.
Ellerbroek, Lüppo
2007-08-01
The Regulation (EC) No. 854/2004 refers in particularly to a broad spectrum of official supervision of products of animal origin. The supervision should be based on the most current relevant information which is available. The proposal presented includes forms for implementation of Food Chain Information (FCI) as laid down in the Regulation (EC) No. 853/2004 as well as suggestions for the implementation of the visual inspection and criteria for a practical approach to assist the competent authority and the business operator. These suggestions are summarised in two forms including the FCI and practical information from the farm of origin as well as from the slaughterhouse needed for the competent authority to permit the visual meat inspection of fattening pigs. The requested information from the farm level include i.e. an animal loss rate during the fattening period and diagnostic findings of carcasses and respectively on organs of the animals during meat inspection procedure. The evaluation of findings in liver and pleura at the slaughterhouse level indicate a correlation to the general health status of the fattening conditions at farm level. The criteria developed are in principle suited for a "gold standard" of the health status of fattening pigs and the criteria may serve as practical implementation of the term Good Farming Practice in relation to consumer protection. Only for fattening pigs deriving from farms fulfilling this "gold standard" the visual meat inspection shall be permitted. It is proposed to integrate the two forms for FCI and additional information for authorisation of visual meat inspection for fattening pigs in the working document of the DG SANCO titled "Commission regulation of laying down specific rules on official controls for the inspection of meat" (SANCO/2696/2006).
NASA Technical Reports Server (NTRS)
Szatkowski, George N.; Dudley, Kenneth L.; Smith, Laura J.; Wang, Chuantong; Ticatch, Larry A.
2014-01-01
Traditional methods to protect composite aircraft from lightning strike damage rely on a conductive layer embedded on or within the surface of the aircraft composite skin. This method is effective at preventing major direct effect damage and minimizes indirect effects to aircraft systems from lightning strike attachment, but provides no additional benefit for the added parasitic weight from the conductive layer. When a known lightning strike occurs, the points of attachment and detachment on the aircraft surface are visually inspected and checked for damage by maintenance personnel to ensure continued safe flight operations. A new multi-functional lightning strike protection (LSP) method has been developed to provide aircraft lightning strike protection, damage detection and diagnosis for composite aircraft surfaces. The method incorporates a SansEC sensor array on the aircraft exterior surfaces forming a "Smart skin" surface for aircraft lightning zones certified to withstand strikes up to 100 kiloamperes peak current. SansEC sensors are open-circuit devices comprised of conductive trace spiral patterns sans (without) electrical connections. The SansEC sensor is an electromagnetic resonator having specific resonant parameters (frequency, amplitude, bandwidth & phase) which when electromagnetically coupled with a composite substrate will indicate the electrical impedance of the composite through a change in its resonant response. Any measureable shift in the resonant characteristics can be an indication of damage to the composite caused by a lightning strike or from other means. The SansEC sensor method is intended to diagnose damage for both in-situ health monitoring or ground inspections. In this paper, the theoretical mathematical framework is established for the use of open circuit sensors to perform damage detection and diagnosis on carbon fiber composites. Both computational and experimental analyses were conducted to validate this new method and system for aircraft composite damage detection and diagnosis. Experimental test results on seeded fault damage coupons and computational modeling simulation results are presented. This paper also presents the shielding effectiveness along with the lightning direct effect test results from several different SansEC LSP and baseline protected and unprotected carbon fiber reinforced polymer (CFRP) test panels struck at 40 and 100 kiloamperes following a universal common practice test procedure to enable damage comparisons between SansEC LSP configurations and common practice copper mesh LSP approaches. The SansEC test panels were mounted in a LSP test bed during the lightning test. Electrical, mechanical and thermal parameters were measured during lightning attachment and are presented with post test nondestructive inspection comparisons. The paper provides correlational results between the SansEC sensors computed electric field distribution and the location of the lightning attachment on the sensor trace and visual observations showing the SansEC sensor's affinity for dispersing the lightning attachment.
NASA Astrophysics Data System (ADS)
Placko, Dominique; Bore, Thierry; Rivollet, Alain; Joubert, Pierre-Yves
2015-10-01
This paper deals with the problem of imaging defects in metallic structures through eddy current (EC) inspections, and proposes an original process for a possible tomographical crack evaluation. This process is based on a semi analytical modeling, called "distributed point source method" (DPSM) which is used to describe and equate the interactions between the implemented EC probes and the structure under test. Several steps will be successively described, illustrating the feasibility of this new imaging process dedicated to the quantitative evaluation of defects. The basic principles of this imaging process firstly consist in creating a 3D grid by meshing the volume potentially inspected by the sensor. As a result, a given number of elemental volumes (called voxels) are obtained. Secondly, the DPSM modeling is used to compute an image for all occurrences in which only one of the voxels has a different conductivity among all the other ones. The assumption consists to consider that a real defect may be truly represented by a superimposition of elemental voxels: the resulting accuracy will naturally depend on the density of space sampling. On other hand, the excitation device of the EC imager has the capability to be oriented in several directions, and driven by an excitation current at variable frequency. So, the simulation will be performed for several frequencies and directions of the eddy currents induced in the structure, which increases the signal entropy. All these results are merged in a so-called "observation matrix" containing all the probe/structure interaction configurations. This matrix is then used in an inversion scheme in order to perform the evaluation of the defect location and geometry. The modeled EC data provided by the DPSM are compared to the experimental images provided by an eddy current imager (ECI), implemented on aluminum plates containing some buried defects. In order to validate the proposed inversion process, we feed it with computed images of various acquisition configurations. Additive noise was added to the images so that they are more representative of actual EC data. In the case of simple notch type defects, for which the relative conductivity may only take two extreme values (1 or 0), a threshold was introduced on the inverted images, in a post processing step, taking advantage of a priori knowledge of the statistical properties of the restored images. This threshold allowed to enhance the image contrast and has contributed to eliminate both the residual noise and the pixels showing non-realistic values.
Determination of linear defect depths from eddy currents disturbances
NASA Astrophysics Data System (ADS)
Ramos, Helena Geirinhas; Rocha, Tiago; Pasadas, Dário; Ribeiro, Artur Lopes
2014-02-01
One of the still open problems in the inspection research concerns the determination of the maximum depth to which a surface defect goes. Eddy current testing being one of the most sensitive well established inspection methods, able to detect and characterize different type of defects in conductive materials, is an adequate technique to solve this problem. This paper reports a study concerning the disturbances in the magnetic field and in the lines of current due to a machined linear defect having different depths in order to extract relevant information that allows the determination of the defect characteristics. The image of the eddy currents (EC) is paramount to understand the physical phenomena involved. The EC images for this study are generated using a commercial finite element model (FLUX). The excitation used produces a uniform magnetic field on the plate under test in the absence of defects and the disturbances due to the defects are compared with those obtained from experimental measurements. In order to increase the limited penetration depth of the method giant magnetoresistors (GMR) are used to lower the working frequency. The geometry of the excitation planar coil produces a uniform magnetic field on an area of around the GMR sensor, inducing a uniform eddy current distribution on the plate. In the presence of defects in the material surface, the lines of currents inside the material are deviated from their uniform direction and the magnetic field produced by these currents is sensed by the GMR sensor. Besides the theoretical study of the electromagnetic system, the paper describes the experiments that have been carried out to support the theory and conclusions are drawn for cracks having different depths.
EMCS EC Connector Inspection Imagery
2018-02-02
iss054e026863 (Feb. 2, 2018) --- The Plant Gravity Perception experiment in a centrifuge before its second run on the European Modular Cultivation System (EMCS) Experiment Container (EC) to test the gravity-sensing ability of plants in microgravity.
Kaufmann, Anton
2010-07-30
Elemental compositions (ECs) can be elucidated by evaluating the high-resolution mass spectra of unknown or suspected unfragmented analyte ions. Classical approaches utilize the exact mass of the monoisotopic peak (M + 0) and the relative abundance of isotope peaks (M + 1 and M + 2). The availability of high-resolution instruments like the Orbitrap currently permits mass resolutions up to 100,000 full width at half maximum. This not only allows the determination of relative isotopic abundances (RIAs), but also the extraction of other diagnostic information from the spectra, such as fully resolved signals originating from (34)S isotopes and fully or partially resolved signals related to (15)N isotopes (isotopic fine structure). Fully and partially resolved peaks can be evaluated by visual inspection of the measured peak profiles. This approach is shown to be capable of correctly discarding many of the EC candidates which were proposed by commercial EC calculating algorithms. Using this intuitive strategy significantly extends the upper mass range for the successful elucidation of ECs. Copyright 2010 John Wiley & Sons, Ltd.
9 CFR 327.26 - Official import inspection marks and devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... horsemeat food products. EC11SE91.027 For application to mule and other (nonhorse) equine carcasses, primal parts, and cuts, not in containers. EC11SE91.028 For application to outside containers of equine meat...
9 CFR 327.26 - Official import inspection marks and devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... parts, and cuts, not in containers. EC11SE91.024 For application to outside containers of meat and meat... carcasses, primal parts, and cuts, not in containers. EC11SE91.026 For application to outside containers of... parts, and cuts, not in containers. EC11SE91.028 For application to outside containers of equine meat...
GCP inspections in Germany and Europe following the implementation of the Directive 2001/20/EC
Göbel, Claus; Baier, Dieter; Ruhfus, Birgit; Hundt, Ferdinand
2009-01-01
Background: The implementation of the Clinical Trials Directive 2001/20/EC and the Good Clinical Practice Directive 2005/28/EC fundamentally restructured and harmonized the conduct of clinical trials in Europe. GCP inspections – which affect study sites, laboratories, sponsors and contract research organizations (CRO) alike – make up an important part of these regulations. A common understanding of how these regulations apply in daily life is however not always ensured. Methods: A working group of the Clinical Research/Quality Assurance subcommittee of the German Association of Research-Based Pharmaceutical Companies (VFA) was established to outline the regulatory requirements, the experience gathered with inspections by means of a survey and to set up guidance on how to manage an inspection. Results and conclusions: The survey, conducted with the help of 15 pharmaceutical companies within the VFA, included a total of 224 inspections (74 inspections in Germany, 150 from other European countries). Most frequent findings in and outside Germany were related to “documentation” (40.5% vs. 21.3%), “investigational new drugs” (16.2% vs. 14.7%), “drug safety” (13.5% vs. 8%) and “application for a clinical trial authorization” (5.4% vs. 12%). From a German perspective, key findings of this working group were the necessity for a clear differentiation of responsibilities between national and federal as well as international authorities, a harmonization of inspection procedures and topics, and a clarification of whether pre-study/on-study and pre-approval/post-approval GCP inspections of the federal higher authority are included in the “Zentralstelle der Länder für Gesundheitsschutz bei Arzneimitteln und Medizinprodukten” (ZLG) requirements. The survey illustrated, that inspections usually are conducted at the investigational site, and that most of the findings are well known and thus could be prevented by communicating and discussing audit results more intensely within study groups. Again, the survey illustrated, that a harmonization of inspections appears warranted. Finally a code of practice is provided that considers these findings and delivers a basis for a successful inspection whether at the sponsor or the GCP site. PMID:19675741
7 CFR 42.123 - Flow diagram for skip lot sampling and inspection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Flow diagram for skip lot sampling and inspection. 42.123 Section 42.123 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING... Procedures § 42.123 Flow diagram for skip lot sampling and inspection. EC02SE91.000 Notes: 1. Only normal...
7 CFR 42.123 - Flow diagram for skip lot sampling and inspection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Flow diagram for skip lot sampling and inspection. 42.123 Section 42.123 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING... Procedures § 42.123 Flow diagram for skip lot sampling and inspection. EC02SE91.000 Notes: 1. Only normal...
7 CFR 42.123 - Flow diagram for skip lot sampling and inspection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Flow diagram for skip lot sampling and inspection. 42.123 Section 42.123 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING... Procedures § 42.123 Flow diagram for skip lot sampling and inspection. EC02SE91.000 Notes: 1. Only normal...
7 CFR 42.123 - Flow diagram for skip lot sampling and inspection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Flow diagram for skip lot sampling and inspection. 42.123 Section 42.123 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING... Procedures § 42.123 Flow diagram for skip lot sampling and inspection. EC02SE91.000 Notes: 1. Only normal...
Joint road safety operations in tunnels and open roads
NASA Astrophysics Data System (ADS)
Adesiyun, Adewole; Avenoso, Antonio; Dionelis, Kallistratos; Cela, Liljana; Nicodème, Christophe; Goger, Thierry; Polidori, Carlo
2017-09-01
The objective of the ECOROADS project is to overcome the barrier established by the formal interpretation of the two Directives 2008/96/EC and 2004/54/EC, which in practice do not allow the same Road Safety Audits/Inspections to be performed inside tunnels. The projects aims at the establishment of a common enhanced approach to road infrastructure and tunnel safety management by using the concepts and criteria of the Directive 2008/96/CE on road infrastructure safety management and the results of related European Commission (EC) funded projects. ECOROADS has already implemented an analysis of national practices regarding Road Safety Inspections (RSI), two Workshops with the stakeholders, and an exchange of best practices between European tunnel experts and road safety professionals, which led to the definition of common agreed safety procedures. In the second phase of the project, different groups of experts and observers applied the above common procedures by inspecting five European road sections featuring both open roads and tunnels in Belgium, Albania, Germany, Serbia and Former Yugoslav Republic of Macedonia. This paper shows the feedback of the 5 joint safety operations and how they are being used for a set of - recommendations and guidelines for the application of the RSA and RSI concepts within the tunnel safety operations.
7 CFR 42.143 - Operating Characteristic (OC) curves for on-line sampling and inspection.
Code of Federal Regulations, 2010 CFR
2010-01-01
...=Number of sample units in a subgroup. T=Subgroup tolerance.L=Acceptance limit.S=Starting value. EC02SE91... ng=Number of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value... of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value. EC02SE91...
75 FR 43801 - Airworthiness Directives; Eurocopter France (ECF) Model EC225LP Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-27
... time. Also, we use inspect rather than check when referring to an action required by a mechanic as... the various levels of government. Therefore, I certify this AD: 1. Is not a ``significant regulatory... compliance time. Also, we use inspect rather than check when referring to an action required by a mechanic as...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY... goats, meat food products in animal casings, and other products as approved by the Administrator, shall... lieu thereof. EC11SE91.000 For application to sheep carcasses, the loins and ribs of pork, beef tails...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY... goats, meat food products in animal casings, and other products as approved by the Administrator, shall... lieu thereof. EC11SE91.000 For application to sheep carcasses, the loins and ribs of pork, beef tails...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY... goats, meat food products in animal casings, and other products as approved by the Administrator, shall... lieu thereof. EC11SE91.000 For application to sheep carcasses, the loins and ribs of pork, beef tails...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY... goats, meat food products in animal casings, and other products as approved by the Administrator, shall... lieu thereof. EC11SE91.000 For application to sheep carcasses, the loins and ribs of pork, beef tails...
NASA Astrophysics Data System (ADS)
Kosugi, Akito; Takemi, Mitsuaki; Tia, Banty; Castagnola, Elisa; Ansaldo, Alberto; Sato, Kenta; Awiszus, Friedemann; Seki, Kazuhiko; Ricci, Davide; Fadiga, Luciano; Iriki, Atsushi; Ushiba, Junichi
2018-06-01
Objective. Motor map has been widely used as an indicator of motor skills and learning, cortical injury, plasticity, and functional recovery. Cortical stimulation mapping using epidural electrodes is recently adopted for animal studies. However, several technical limitations still remain. Test-retest reliability of epidural cortical stimulation (ECS) mapping has not been examined in detail. Many previous studies defined evoked movements and motor thresholds by visual inspection, and thus, lacked quantitative measurements. A reliable and quantitative motor map is important to elucidate the mechanisms of motor cortical reorganization. The objective of the current study was to perform reliable ECS mapping of motor representations based on the motor thresholds, which were stochastically estimated by motor evoked potentials and chronically implanted micro-electrocorticographical (µECoG) electrode arrays, in common marmosets. Approach. ECS was applied using the implanted µECoG electrode arrays in three adult common marmosets under awake conditions. Motor evoked potentials were recorded through electromyographical electrodes implanted in upper limb muscles. The motor threshold was calculated through a modified maximum likelihood threshold-hunting algorithm fitted with the recorded data from marmosets. Further, a computer simulation confirmed reliability of the algorithm. Main results. Computer simulation suggested that the modified maximum likelihood threshold-hunting algorithm enabled to estimate motor threshold with acceptable precision. In vivo ECS mapping showed high test-retest reliability with respect to the excitability and location of the cortical forelimb motor representations. Significance. Using implanted µECoG electrode arrays and a modified motor threshold-hunting algorithm, we were able to achieve reliable motor mapping in common marmosets with the ECS system.
Kosugi, Akito; Takemi, Mitsuaki; Tia, Banty; Castagnola, Elisa; Ansaldo, Alberto; Sato, Kenta; Awiszus, Friedemann; Seki, Kazuhiko; Ricci, Davide; Fadiga, Luciano; Iriki, Atsushi; Ushiba, Junichi
2018-06-01
Motor map has been widely used as an indicator of motor skills and learning, cortical injury, plasticity, and functional recovery. Cortical stimulation mapping using epidural electrodes is recently adopted for animal studies. However, several technical limitations still remain. Test-retest reliability of epidural cortical stimulation (ECS) mapping has not been examined in detail. Many previous studies defined evoked movements and motor thresholds by visual inspection, and thus, lacked quantitative measurements. A reliable and quantitative motor map is important to elucidate the mechanisms of motor cortical reorganization. The objective of the current study was to perform reliable ECS mapping of motor representations based on the motor thresholds, which were stochastically estimated by motor evoked potentials and chronically implanted micro-electrocorticographical (µECoG) electrode arrays, in common marmosets. ECS was applied using the implanted µECoG electrode arrays in three adult common marmosets under awake conditions. Motor evoked potentials were recorded through electromyographical electrodes implanted in upper limb muscles. The motor threshold was calculated through a modified maximum likelihood threshold-hunting algorithm fitted with the recorded data from marmosets. Further, a computer simulation confirmed reliability of the algorithm. Computer simulation suggested that the modified maximum likelihood threshold-hunting algorithm enabled to estimate motor threshold with acceptable precision. In vivo ECS mapping showed high test-retest reliability with respect to the excitability and location of the cortical forelimb motor representations. Using implanted µECoG electrode arrays and a modified motor threshold-hunting algorithm, we were able to achieve reliable motor mapping in common marmosets with the ECS system.
9 CFR 352.7 - Marking inspected products.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., exotic animal tongues, and exotic animal hearts. EC11SE91.031 (2) For application to exotic animal calf... used on shipping containers, bond labels, artificial casings, and other articles with the approval of...
9 CFR 352.7 - Marking inspected products.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., exotic animal tongues, and exotic animal hearts. EC11SE91.031 (2) For application to exotic animal calf... used on shipping containers, bond labels, artificial casings, and other articles with the approval of...
NASA Astrophysics Data System (ADS)
Olivieri, Pierre
Non destructive testing (NDT) plays an important role in the aerospace industry during the fabrication and maintenance of the structures built and is used, among other useful applications, to detect flaws such as cracks at an early stage. However, NDT techniques are still mainly done manually, especially on complex aeronautical structures, which then results in several drawbacks. In addition to be difficult and time-consuming, reliability and repeatability of inspection results are likely to be affected, since they rely on each operator's experience and dexterity. The present thesis is part of a larger project (MANU-418) of the Consortium for Research and Innovation in Aerospace in Quebec (CRIAQ). In this project, it has been proposed to develop a system using a 6-DOF manipulator arm to automate three particular NDT techniques often needed in the aerospace industry: eddy current testing (ECT), fluorescent penetrant inspection (FPI), and infrared thermography (IRT). The main objective of the MANU-418 project is to demonstrate the efficiency of the developed system and provide inspection results of surface and near surface flaws (cracks usually) at least as reliably and repeatably as inspection results from a human operator. One specific objective stemming from the main objective of the project is to develop a methodology and a software tool to generate covering paths adapted for the three aforementioned NDT techniques to inspect the complex surfaces of aerospace structures. The present thesis aims at reaching this specific objective. At first, geometrical and topological properties of the surfaces considered in this project are defined (flat surfaces, round and straight edges, cylindrical or near cylindrical surfaces, holes). It is also assumed that the 3D model of the surface to inspect is known in advance. Moreover, it has been decided within the framework of the MANU-418 project to give priority to the automation of ECT compared with the other techniques (FPI and IRT). As a result, the methodology developed to generate inspection paths is more closely focused on path constraints relative to the manual operations of ECT using a differential eddy current probe (named here EC probe), but it is developed to be flexible enough to be used with the other techniques as well. Common inspection paths for ECT are usually defined by a sweeping motion using a zigzag pattern with the EC probe in mild contact with the inspected surface. Moreover, the main axis of the probe must keep a normal orientation with the surface, and the alignment of its two coils must always be oriented along the direction of its motion. A first methodology is then proposed to generate covering paths on the whole surface of interest while meeting all EC probe motion constraints. First, the surface is meshed with triangular facets, and then it is subdivided into several patches such that their geometry and topology are simpler than the whole surface. Paths are then generated on each patch by intersecting their facets with offset section planes defined along a sweeping direction. Furthermore, another methodology is developed to generate paths around an indication (namely a small area where the presence of a flaw is suspected) whose position and orientation are assumed to be known a priori.. Then, a software tool with a graphical user interface has been developed in the MATLAB environment to generate inspection paths based on these methodologies. A set of path parameters can be changed by the user to get desired paths (distance between passes, sweep direction, etc.). Once paths are computed, an ordered list of coordinates (positions and orientations) of the tool is exported in an EXCEL spreadsheet so that it could be used with a real robot. In this research, these data are then used to perform simulations of trajectories (path described as a function of the time) with a MotoMan robot (model SV3XL) using the MotoSim software. After validation of these trajectories in this software (absence of collisions, positions are all reachable, etc.), they are finally converted into instructions for the real MotoMan robot to proceed with experimental tests. These first simulations and experimentations on a MotoMan robot of the generated paths have given results close to the expected inspection trajectories used manually in the NDT techniques considered, especially for the ECT technique. Nevertheless, it is strongly recommended to validate this path generation method with more experimental tests. For instance, a "test" tool could be manufactured to measure errors of position and orientation of this tool with respect to expected trajectories on a typical complex aeronautical structure. (Abstract shortened by UMI.).
NASA Technical Reports Server (NTRS)
Faur, Maria; Faur, Mircea; Weinberg, Irving; Goradia, Manju; Vargas, Carlos
1991-01-01
An extensive experimental study was conducted using various electrolytes in an effort to find an appropriate electrolyte for anodic dissolution of InP. From the analysis of electrochemical characteristics in the dark and under different illumination levels, x ray photoelectron spectroscopy and SEM/Nomarski inspection of the surfaces, it was determined that the anodic dissolution of InP front surface layers by FAP electrolyte is a very good choice for rendering smooth surfaces, free of oxides and contaminants and with good electrical characteristics. The FAP electrolyte, based on HF, CH3COOH, and H2O2 appears to be inherently superior to previously reported electrolytes for performing accurate EC-V profiling of InP at current densities of up to 0.3 mA/sq cm. It can also be used for accurate electrochemical revealing of either precipitates or dislocation density with application to EPD mapping as a function of depth, and for defect revealing of multilayer InP structures at any depth and/or at the interfaces.
Incision of the heart during meat inspection of fattening pigs - A risk-profile approach.
Leps, J; Fries, R
2009-01-01
Meat inspection in the EU is based on Regulation (EC) 854/2004. Accordingly a risk based meat inspection should be implemented. In this paper, the incision of the heart in pig meat inspection is discussed with respect to efficacy. The incision especially can reveal the presence of endocarditis. Here, Erysipelothrixrhusiopathiae (E. rhusiopathiae) and/or Streptococcussuis (S. suis) are of particular concern. Both agents are regarded to be zoonotic agents. There is some evidence for infection of humans via an alimentary pathway. Hence, the occurrence of E. rhusiopathiae and S. suis is a concern of public health (PH) as well as veterinary public health (VPH). However, other measures, including on-farm disease prevention and diagnosis, seem to be more important for food safety. It is concluded that the incision and inspection of the heart is not justifiable with respect to PH aspects.
Electronic cigarette use behaviors and motivations among smokers and non-smokers.
Sussan, Thomas E; Shahzad, Fatima G; Tabassum, Eefa; Cohen, Joanna E; Wise, Robert A; Blaha, Michael J; Holbrook, Janet T; Biswal, Shyam
2017-09-08
The use of electronic cigarettes (EC) has risen exponentially over the past decade, including among never smokers, and ECs are now the most popular tobacco product among teenagers in the US. While, EC manufacturers utilize numerous marketing strategies to target both smokers and non-smokers, it is unclear how perceptions and behaviors differ between these two groups. We conducted a survey of 320 adults either via online surveys or in Baltimore vape shops to determine demographics, behaviors, perceptions, and motivations underlying use of ECs. Our survey respondents were predominantly young, Caucasian males, 74% of whom identified themselves as former smokers, while 20% identified as current smokers and 6% were never smokers. Former smokers reported a longer history of EC use and higher nicotine concentrations than current smokers. For former and current smokers, the primary motivation for EC use was assistance to quit smoking, and nearly half indicated that they plan to reduce their nicotine concentration and eventually quit using ECs. Among former smokers, self-reports on use and measures of dependence were consistent with nicotine replacement as their primary motivation. The majority of former and current smokers also reported that their respiratory health had improved as a result of EC use, although this effect was stronger for former smokers. Never smokers reported less frequent EC use and dependence compared to former and current smokers. Their motivations for use were more commonly for enjoyment and popularity, and they displayed a reduced desire to eventually quit using ECs. These responses provide insight into the underlying thoughts and behaviors of smoking and non-smoking EC users and also suggest that never smoking EC users are an emerging demographic with different motivations and perceptions than those of current and former smokers.
Awad, Louis N.; Reisman, Darcy S.; Pohlig, Ryan T.; Binder-Macleod, Stuart A.
2015-01-01
Background Neurorehabilitation efforts have been limited in their ability to restore walking function after stroke. Recent work has demonstrated proof-of-concept for a Functional Electrical Stimulation (FES)-based combination therapy designed to improve poststroke walking by targeting deficits in paretic propulsion. Objectives To determine the effects on the energy cost of walking (EC) and long-distance walking ability of locomotor training that combines fast walking with FES to the paretic ankle musculature (FastFES). Methods Fifty participants >6 months poststroke were randomized to 12 weeks of gait training at self-selected speeds (SS), fast speeds (Fast), or FastFES. Participants’ 6-Minute Walk Test (6MWT) distance and EC at comfortable (EC-CWS) and fast (EC-Fast) walking speeds were measured pretraining, posttraining, and at a 3-month follow-up. A reduction in EC-CWS, independent of changes in speed, was the primary outcome. Also evaluated were group differences in the number of 6MWT responders and moderation by baseline speed. Results When compared with SS and Fast, FastFES produced larger reductions in EC (p’s ≤0.03). FastFES produced reductions of 24% and 19% in EC-CWS and EC-Fast (p’s <0.001), whereas neither Fast nor SS influenced EC. Between-group 6MWT differences were not observed; however, 73% of FastFES and 68% of Fast participants were responders, in contrast to 35% of SS participants. Conclusions Combining fast locomotor training with FES is an effective approach to reducing the high EC of persons poststroke. Surprisingly, differences in 6MWT gains were not observed between groups. Closer inspection of the 6MWT and EC relationship and elucidation of how reduced EC may influence walking-related disability is warranted. PMID:26621366
Code of Federal Regulations, 2010 CFR
2010-01-01
... livers, beef tongues, beef hearts, and smoked meats not in casings. EC11SE91.003 For application to... on shipping containers, band labels, artificial casings, and other articles with the approval of the...
NASA Astrophysics Data System (ADS)
Larson, B. F.; Lo, C. C. H.; Nakagawa, N.
2010-02-01
This paper reports on work conducted to investigate the effect that electrical discharge machining (EDM) notch width has on the eddy current (EC) signal as a function of coil drive frequency. The notch results are also compared to EC signals from laboratory-grown fatigue cracks. This study builds upon previous work with titanium, Inconel and aluminum materials where the signal amplitude was shown to decrease, as expected, as the notch width decreases. The trend was captured well by numerical results and this allowed estimates to be made about the signals from idealized "zero-width" notches. The results indicated that the signal reduction factor from a 0.127 mm (0.005 inch) wide, rectangular notch to a theoretical zero-width semi-elliptical notch of the same size ranged from 25 to 42% for low conductivity materials when data was collected at 2 MHz. For aluminum, the difference between signals from 0.127 mm wide notches and estimated signals for zero-width notches was approximately 50%. However, 2 MHz is an uncommonly high frequency for inspecting aluminum alloys so additional work was necessary to investigate the notch width effect at lower frequencies. This study sought to determine how the notch-width effect changed as a function of frequency for high conductivity materials such as aluminum.
A new verification film system for routine quality control of radiation fields: Kodak EC-L.
Hermann, A; Bratengeier, K; Priske, A; Flentje, M
2000-06-01
The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged "good", only 18% were classified "moderate" or "poor" 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be "good". The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated.
Vape and Aviate: Electronic-Cigarette Use and Misuse in Naval Aviation.
Hall, Matthew T; Austin, Ryan P; Do, Tai A; McGlynn, Andrea
2018-03-01
Electronic cigarettes (EC) are an emerging form of nicotine replacement that has had a discernible increase in prevalence in the general population. Little is known regarding EC use among different military demographic groups or the extent of influence that social determinants of health may have on the behavior. The purpose of this study was to assess the prevalence and correlates of EC use in a select population of active duty U.S. Naval personnel. This study is unique in that it allows for EC behavior comparison between a traditionally healthy demographic (aviators, a subset of aircrew) and a representative general military population sample. Cross-sectional survey data were collected anonymously and analyzed in 2015-2016. Active duty Naval personnel (n = 977) were asked about ever trying ECs, frequency of use, and when was the last time an EC was used. Participants were assessed similarly regarding cigarette use. Descriptive and inferential statistics as well as multinomial logistic regression analyses were conducted using categorical and ordinal variables assigned to usage and demographic factors. This protocol was approved by the Institutional Review Board at Naval Hospital Portsmouth located in Portsmouth, Virginia. Within the study population, 31.4% have tried ECs, 9.3% were current users, and only 3.8% were dual (EC and cigarettes) users. EC use was significantly associated with paygrade (enlisted), primary job duty (non-aircrew), and education (less than a bachelor degree, p < 0.001, p < 0.01, and p < 0.001, respectively). ECs were used at some point as a smoking cessation tool for 43.6% of current EC users (p < 0.001), 21.6% of current smokers, and only 5.6% of former smokers. Continued EC use after ever trying ECs (30.0%) was only slightly more prevalent as continued cigarette use after ever trying cigarettes (27.3%). Smokers were nearly five times more likely to currently use ECs compared with non-smokers. Trying cigarettes was associated with nearly 12 times the risk for trying ECs compared with those who never tried cigarettes. No significant misuse of ECs was noted; however, several cases of drinking, tasting, and touching EC fluid were reported. This study is unique in that it examines the use of electronic cigarettes among selected healthy and baseline groups within the active duty U.S. Navy population. The current prevalence of EC use among active duty personnel is much higher than previously thought. Continued use of ECs after ever trying them appears to exceed that of cigarettes even among healthy populations such as aircrew. The findings of increased risk of EC use among those with lower income and less than a bachelor's degree suggest social determinants of health implications. This study sheds new light on EC use, characteristics of use, addiction implications, and highlights concerns for a growing health risk behavior.
2000-09-18
An engineer at AeroVironment's Design Development Center in Simi Valley, California, closely inspects a set of silicon solar cells for potential defects. The cells, fabricated by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the Helios Prototype solar-powered aircraft to provide power to its 14 electric motors and operating systems.
78 FR 30793 - Airworthiness Directives; Eurocopter Deutschland GmbH Model Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
... Deutschland GmbH Model Helicopters AGENCY: Federal Aviation Administration (FAA) DOT. ACTION: Notice of... Deutschland GmbH (Eurocopter) Model EC135 P1, P2, P2+, T1, T2, and T2+ helicopters to require inspecting each...): Eurocopter Deutschland GmbH: Docket No. FAA-2013-0446; Directorate Identifier 2010-SW-007-AD. (a...
NASA Astrophysics Data System (ADS)
Zimovets, I. V.; Sharykin, I. N.; Wang, R.; Liu, Y. D.; Kosovichev, A. G.
2017-12-01
It is believed that solar flares are a result of release of free magnetic energy contained in electric currents (ECs) flowing in active regions (ARs). However, there are still debates whether the primary energy release and acceleration of electrons take place in coronal current sheets or in chromospheric footpoints of current-carrying magnetic flux tubes (loops). We present results of an observational statistical study of spatial relationship between hard X-ray (HXR; EHXR≥50keV) footpoint sources detected by RHESSI and vertical photospheric ECs calculated using vector magnetograms obtained from the SDO/HMI data. We found that for a sample of 47 flares (from C3.0 to X3.1 class) observed on the solar disk by both instruments in 2010-2016, at least one HXR source was in a region of strong (within 20% of the maximum EC density in the corresponding ARs) vertical ECs having the form of a ribbon (79%) or an island (21%). The total vertical ECs in such HXR sources are in the range of 1010-1013 A. The EC density is in the range of 0.01-1.0 A/m2. We found no correlation between intensity of the HXR sources and the EC density. By comparing pre-flare and post-flare EC maps we did not find evidences of significant dissipation of vertical ECs in the regions corresponding to the HXR sources. In some cases, we found amplification of ECs during flares. We discuss effects of sensitivity and angular resolution of RHESSI and SDO/HMI. In general, the results indicate that there is a link between the flare HXR footpoint sources and enhanced vertical ECs in the photosphere. However, the results do not support a concept of electron acceleration by the electric field excited in footpoints of current-carrying loops due to some (e.g. Rayleigh-Taylor) instabilities (Zaitsev et al., 2016), since strong correlation between the HXR intensity and the EC density is expected in such concept.
Damage Detection Response Characteristics of Open Circuit Resonant (SansEC) Sensors
NASA Technical Reports Server (NTRS)
Dudley, Kenneth L.; Szatkowski, George N.; Smith, Laura J.; Koppen, Sandra V.; Ely, Jay J.; Nguyen, Truong X.; Wang, Chuantong; Ticatch, Larry A.; Mielnik, John J.
2013-01-01
The capability to assess the current or future state of the health of an aircraft to improve safety, availability, and reliability while reducing maintenance costs has been a continuous goal for decades. Many companies, commercial entities, and academic institutions have become interested in Integrated Vehicle Health Management (IVHM) and a growing effort of research into "smart" vehicle sensing systems has emerged. Methods to detect damage to aircraft materials and structures have historically relied on visual inspection during pre-flight or post-flight operations by flight and ground crews. More quantitative non-destructive investigations with various instruments and sensors have traditionally been performed when the aircraft is out of operational service during major scheduled maintenance. Through the use of reliable sensors coupled with data monitoring, data mining, and data analysis techniques, the health state of a vehicle can be detected in-situ. NASA Langley Research Center (LaRC) is developing a composite aircraft skin damage detection method and system based on open circuit SansEC (Sans Electric Connection) sensor technology. Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage structures, empennage structures, control surfaces and aircraft skins. SansEC sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect various types of damage in composite materials. The source cause of the in-service damage (lightning strike, impact damage, material fatigue, etc.) to the aircraft composite is not relevant. The sensor will detect damage independent of the cause. Damage in composite material is generally associated with a localized change in material permittivity and/or conductivity. These changes are sensed using SansEC. The unique electrical signatures (amplitude, frequency, bandwidth, and phase) are used for damage detection and diagnosis. An operational system and method would incorporate a SansEC sensor array on select areas of the aircraft exterior surfaces to form a "Smart skin" sensing surface. In this paper a new method and system for aircraft in-situ damage detection and diagnosis is presented. Experimental test results on seeded fault damage coupons and computational modeling simulation results are presented. NASA LaRC has demonstrated with individual sensors that SansEC sensors can be effectively used for in-situ composite damage detection of delamination, voids, fractures, and rips. Keywords: Damage Detection, Composites, Integrated Vehicle Health Monitoring (IVHM), Aviation Safety, SansEC Sensors
Treatment of leachate by electrocoagulation using aluminum and iron electrodes.
Ilhan, Fatih; Kurt, Ugur; Apaydin, Omer; Gonullu, M Talha
2008-06-15
In this paper, treatment of leachate by electrocoagulation (EC) has been investigated in a batch process. The sample of leachate was supplied from Odayeri Landfill Site in Istanbul. Firstly, EC was compared with classical chemical coagulation (CC) process via COD removal. The first comparison results with 348 A/m2 current density showed that EC process has higher treatment performance than CC process. Secondly, effects of process variables such as electrode material, current density (from 348 to 631 A/m2), pH, treatment cost, and operating time for EC process are investigated on COD and NH4-N removal efficiencies. The appropriate electrode type search for EC provided that aluminum supplies more COD removal (56%) than iron electrode (35%) at the end of the 30 min operating time. Finally, EC experiments were also continued to determine the efficiency of ammonia removal, and the effects of current density, mixing, and aeration. All the findings of the study revealed that treatment of leachate by EC can be used as a step of a joint treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Neeraj; Büchner, Jörg; Max Planck Institute for Solar System Research, Justus-Von-Liebig-Weg-3, Göttingen
In collisionless magnetic reconnection, electron current sheets (ECS) with thickness of the order of an electron inertial length form embedded inside ion current sheets with thickness of the order of an ion inertial length. These ECS's are susceptible to a variety of instabilities which have the potential to affect the reconnection rate and/or the structure of reconnection. We carry out a three dimensional linear eigen mode stability analysis of electron shear flow driven instabilities of an electron scale current sheet using an electron-magnetohydrodynamic plasma model. The linear growth rate of the fastest unstable mode was found to drop with themore » thickness of the ECS. We show how the nature of the instability depends on the thickness of the ECS. As long as the half-thickness of the ECS is close to the electron inertial length, the fastest instability is that of a translational symmetric two-dimensional (no variations along flow direction) tearing mode. For an ECS half thickness sufficiently larger or smaller than the electron inertial length, the fastest mode is not a tearing mode any more and may have finite variations along the flow direction. Therefore, the generation of plasmoids in a nonlinear evolution of ECS is likely only when the half-thickness is close to an electron inertial length.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... subsequent Eddy Current inspection (NDI) [non-destructive inspection] of the same area to detect cracks... inspections are eddy current inspections. The modification includes cold expansion of the former lower wing... with consequent loss of control. * * * * * The new inspections are eddy current inspections. The...
77 FR 21402 - Airworthiness Directives; Sikorsky Aircraft Corporation Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... option is to conduct an eddy current inspection and the other option is to conduct a visual inspection... blade sanding inspection rather than the eddy current inspection, at an average labor rate of $85 per.... (1) Inspect by using either an eddy current inspection in accordance with paragraphs B.(1)(a) through...
Association between Electronic Cigarette Use and Asthma among High School Students in South Korea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Jun Ho; Paik, Samuel Y.
Little is known about health outcomes related to electronic cigarette (EC) use, despite its growing popularity. The aim of this study is to investigate the association between EC use and asthma. The study design is a cross-sectional study. A total of 35,904 high school students were included as the final study population. The presence of asthma was based on a student’s self-reported doctor diagnosis of asthma in the past 12 months. Results showed prevalence rates of asthmatics in ‘current EC users’ (n = 2,513), ‘former EC users’ (n = 2,078), and ‘never EC users’ (n = 31,313), were 3.9% (nmore » = 98), 2.2% (n = 46) and 1.7% (n = 530), respectively. Comparing ‘current EC’ users with ‘never EC’ users, the unadjusted OR for asthma was 2.36 (95% CI: 1.89–2.94). In order to control for the effect of conventional cigarette (CC) smoking, after stratifying the subjects by the three CC smoking categories (never CC, former CC, and current CC), within the ‘never CC’ category, the unadjusted OR for asthma for ‘current EC’ users was 3.41 (95% CI: 1.79–6.49), and the adjusted OR was 2.74 (95% CI: 1.30–5.78). Severe asthma was reflected by the number of days absent from school due to asthma symptoms; current EC users had the highest adjusted OR for severe asthma compared to ‘never EC’ users. In conclusion, when compared to a reference population of high school students in South Korea, EC users have an increased association with asthma and are more likely to have had days absent from school due to severe asthma symptoms. In conclusion, the results indicate that EC use may be a risk factor for asthma. The results may be useful in developing a scientific basis for the evaluation of a potential health hazard by EC.« less
Association between Electronic Cigarette Use and Asthma among High School Students in South Korea
Cho, Jun Ho; Paik, Samuel Y.
2016-03-04
Little is known about health outcomes related to electronic cigarette (EC) use, despite its growing popularity. The aim of this study is to investigate the association between EC use and asthma. The study design is a cross-sectional study. A total of 35,904 high school students were included as the final study population. The presence of asthma was based on a student’s self-reported doctor diagnosis of asthma in the past 12 months. Results showed prevalence rates of asthmatics in ‘current EC users’ (n = 2,513), ‘former EC users’ (n = 2,078), and ‘never EC users’ (n = 31,313), were 3.9% (nmore » = 98), 2.2% (n = 46) and 1.7% (n = 530), respectively. Comparing ‘current EC’ users with ‘never EC’ users, the unadjusted OR for asthma was 2.36 (95% CI: 1.89–2.94). In order to control for the effect of conventional cigarette (CC) smoking, after stratifying the subjects by the three CC smoking categories (never CC, former CC, and current CC), within the ‘never CC’ category, the unadjusted OR for asthma for ‘current EC’ users was 3.41 (95% CI: 1.79–6.49), and the adjusted OR was 2.74 (95% CI: 1.30–5.78). Severe asthma was reflected by the number of days absent from school due to asthma symptoms; current EC users had the highest adjusted OR for severe asthma compared to ‘never EC’ users. In conclusion, when compared to a reference population of high school students in South Korea, EC users have an increased association with asthma and are more likely to have had days absent from school due to severe asthma symptoms. In conclusion, the results indicate that EC use may be a risk factor for asthma. The results may be useful in developing a scientific basis for the evaluation of a potential health hazard by EC.« less
Assessing risk factors in the organic control system: evidence from inspection data in Italy.
Zanoli, Raffaele; Gambelli, Danilo; Solfanelli, Francesco
2014-12-01
Certification is an essential feature in organic farming, and it is based on inspections to verify compliance with respect to European Council Regulation-EC Reg. No 834/2007. A risk-based approach to noncompliance that alerts the control bodies to activate planning inspections would contribute to a more efficient and cost-effective certification system. An analysis of factors that can affect the probability of noncompliance in organic farming has thus been developed. This article examines the application of zero-inflated count data models to farm-level panel data from inspection results and sanctions obtained from the Ethical and Environmental Certification Institute, one of the main control bodies in Italy. We tested many a priori hypotheses related to the risk of noncompliance. We find evidence of an important role for past noncompliant behavior in predicting future noncompliance, while farm size and the occurrence of livestock also have roles in an increased probability of noncompliance. We conclude the article proposing that an efficient risk-based inspection system should be designed, weighting up the known probability of occurrence of a given noncompliance according to the severity of its impact. © 2014 Society for Risk Analysis.
78 FR 27001 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... one-time mid- frequency eddy current (MFEC) inspection, a low-frequency eddy current (LFEC) inspection... new AD instead requires repetitive external eddy current inspections for cracking of certain fuselage crown lap joints, and corrective actions if necessary; internal eddy current and detailed inspections...
78 FR 40050 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-03
... inspections or high frequency eddy current inspections for cracks of the blended area of the fuselage skin... repetitive external detailed inspections or high frequency eddy current inspections for cracks of the blended..., 2009) is August 3, 2009. (h) Repetitive High Frequency Eddy Current (HFEC) Inspections For airplanes on...
Fully non-inductive second harmonic electron cyclotron plasma ramp-up in the QUEST spherical tokamak
NASA Astrophysics Data System (ADS)
Idei, H.; Kariya, T.; Imai, T.; Mishra, K.; Onchi, T.; Watanabe, O.; Zushi, H.; Hanada, K.; Qian, J.; Ejiri, A.; Alam, M. M.; Nakamura, K.; Fujisawa, A.; Nagashima, Y.; Hasegawa, M.; Matsuoka, K.; Fukuyama, A.; Kubo, S.; Shimozuma, T.; Yoshikawa, M.; Sakamoto, M.; Kawasaki, S.; Nakashima, H.; Higashijima, A.; Ide, S.; Maekawa, T.; Takase, Y.; Toi, K.
2017-12-01
Fully non-inductive second (2nd) harmonic electron cyclotron (EC) plasma current ramp-up was demonstrated with a newlly developed 28 GHz system in the QUEST spherical tokamak. A high plasma current of 54 kA was non-inductively ramped up and sustained stably for 0.9 s with a 270 kW 28 GHz wave. A higher plasma current of 66 kA was also non-inductively achieved with a slow ramp-up of the vertical field. We have achieved a significantly higher plasma current than those achieved previously with the 2nd harmonic EC waves. This fully non-inductive 2nd harmonic EC plasma ramp-up method might be useful for future burning plasma devices and fusion reactors, in particular for operations at half magnetic field with the same EC heating equipment.
Tseng, Tuo-Yen; Ostroff, Jamie S; Campo, Alena; Gerard, Meghan; Kirchner, Thomas; Rotrosen, John; Shelley, Donna
2016-10-01
Electronic cigarette (EC) use is growing dramatically with use highest among young adults and current smokers. One of the most common reasons for using ECs is interest in quitting or reducing cigarettes per day (CPD); however there are few randomized controlled trials (RCT) on the effect of ECs on smoking abstinence and reduction. We conducted a two-arm; double-blind RCT. Subjects were randomized to receive 3-weeks of either disposable 4.5% nicotine EC (intervention) or placebo EC. The primary outcome was self-reported reduction of at least 50% in the number of CPDs smoked at week 3 (end of treatment) compared to baseline. Study subjects (n = 99) were young adult (21-35), current smokers (smoked ≥ 10 CPDs) living in NYC. Compared with baseline, a significant reduction in CPDs was observed at both study time periods (1 and 3 weeks) for intervention (P < .001) and placebo (P < .001) groups. Between-group analyses showed significantly fewer CPDs in the intervention group compared to the placebo group at week 3 (P = .03), but not at any other follow-up periods. The logistic regression analysis showed that using a greater number of ECs, treatment condition and higher baseline readiness to quit were significantly associated with achieving at least 50% reduction in CPDs at the end of treatment. A diverse young adult sample of current everyday smokers, who were not ready to quit, was able to reduce smoking with the help of ECs. Further study is needed to establish the role of both placebo and nicotine containing ECs in increasing both reduction and subsequent cessation. Despite the critical need for well-designed clinical trials on the effect of ECs on cessation and cigarette reduction, the majority of studies have been observational or noncomparative intervention designs. Only three RCTs studying ECs as a cessation or reduction intervention have been published, and none were conducted in the United States. The current study adds knowledge to current literature on the feasibility of using ECs to aid smoking reduction among young smokers in US urban populations. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Yong, Hua-Hie; Borland, Ron; Balmford, James; McNeill, Ann; Hitchman, Sara; Driezen, Pete; Thompson, Mary E; Fong, Geoffrey T; Cummings, K Michael
2015-10-01
E-cigarettes (ECs) have gained significant attention in recent years. They have been introduced in jurisdictions with divergent existing laws that affect their legality. This provides the opportunity for natural experiments to assess effects of such laws in some cases independent of any formulated government policy. We compare patterns of EC awareness and use over a 3 year period in Australia where laws severely restrict EC availability, with awareness and use in the United Kingdom where ECs are readily available. Data analyzed come from Waves 8 and 9 (collected in 2010 and 2013, respectively) of the International Tobacco Control surveys in Australia and the United Kingdom (approximately 1,500 respondents per wave per country). Across both waves, EC awareness, trial, and use among current and former smokers were significantly greater in the United Kingdom than in Australia, but all 3 of these measures increased significantly between 2010 and 2013 in both countries, and the rate of increase was equivalent between countries. Seventy-three percent of U.K. respondents reported that their current brands contained nicotine as did 43% in Australia even though sale, possession and/or use of nicotine-containing ECs without a permit are illegal in Australia. EC use was greater among smokers in both countries, at least in part due to less uptake by ex-smokers. EC awareness and use have risen rapidly between 2010 and 2013 among current and former smokers in both Australia and the United Kingdom despite different EC regulatory environments. Substantial numbers in both countries are using ECs that contain nicotine. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Odera, Joab Otieno; Odera, Elizabeth; Githang’a, Jessie; Walong, Edwin Oloo; Li, Fang; Xiong, Zhaohui; Chen, Xiaoxin Luke
2017-01-01
Kenya belongs to a high incidence region known as Africa’s esophageal cancer (EC) corridor. It has one of the highest incidence rates of EC worldwide, but research on EC in Kenya has gone highly unnoticed. EC in Kenya is unique in its high percentage of young cases (< 30 years of age). In this review, we show the current status of EC in the country. We mainly focus on significant risk factors such as alcohol drinking, genetic factors, malnutrition and hot food/drink. Future directions in the study and prevention of EC in Kenya are also discussed. PMID:29082268
Interaction between endothelial cells and albumin encapsulated droplets in Poiseuille flow
NASA Astrophysics Data System (ADS)
Seda, Robinson; Fowlkes, J. Brian; Bull, Joseph
2012-11-01
Acoustic droplet vaporization (ADV) of DDFP encapsulated microdroplets has the ability to transform these emulsions into larger gas emboli capable of occluding blood vessels for therapy. An albumin shell is able to stabilize the droplet's superheated core, but can also interact with endothelial cells (EC) at the vessel wall if in close proximity. Radial migration of these microdroplets could bring them close enough to make this interaction possible leading to bioeffects that include cell detachment and death if an ADV event occurs. The purpose of this study is to investigate the hydrodynamic conditions (i.e. shear stresses) that make possible this EC-droplet interaction. A flow chamber coated with a monolayer of EC and connected to a syringe pump is used to flow a DDFP droplet solution at physiological shear stresses (1-50 dyne/cm2) and inspected for droplet attachment. Droplets have been observed to interact and reversibly attach to EC in a static environment, thus it is expected that at low shear stress values interaction and further attachment will be possible. Knowing the flow conditions at which this interaction is likely to occur will aid in preventative measures to avoid significant bioeffects associated with ADV near the vessel wall. This work is supported by NIH grant R01EB006476.
78 FR 71998 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
... initial and repetitive [detailed or eddy current] inspections [for cracking and damage and replacement if... the detailed or eddy current inspection for cracking of the pilot-side rudder pedal tubes, specified... within 600 flight cycles thereafter. (2) If the most recent inspection was an eddy current inspection...
77 FR 61550 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
... inspection required by AD 2003-14-06 only terminates the external eddy current inspections required by..., which should not terminate the detailed or eddy current inspection, as specified. We find that... terminating action ``before the effective date of this AD'' terminates the eddy current inspections required...
NASA Technical Reports Server (NTRS)
Wang, Chuantong; Dudley, Kenneth L.; Szatkowski, George N.
2012-01-01
Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage and empennage structures, control surfaces and coverings. However, the potential damage from the direct and indirect effects of lightning strikes is of increased concern to aircraft designers and operators. When a lightning strike occurs, the points of attachment and detachment on the aircraft surface must be found by visual inspection, and then assessed for damage by maintenance personnel to ensure continued safe flight operations. In this paper, a new method and system for aircraft in-situ damage detection and diagnosis are presented. The method and system are based on open circuit (SansEC) sensor technology developed at NASA Langley Research Center. SansEC (Sans Electric Connection) sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect damage in composite materials. Damage in composite material is generally associated with a localized change in material permittivity and/or conductivity. These changes are sensed using SansEC. Unique electrical signatures are used for damage detection and diagnosis. NASA LaRC has both experimentally and theoretically demonstrated that SansEC sensors can be effectively used for in-situ composite damage detection.
Qu, Xin; Hall, Alex; DeAngelis, Anthony M.; ...
2018-01-11
Differences among climate models in equilibrium climate sensitivity (ECS; the equilibrium surface temperature response to a doubling of atmospheric CO2) remain a significant barrier to the accurate assessment of societally important impacts of climate change. Relationships between ECS and observable metrics of the current climate in model ensembles, so-called emergent constraints, have been used to constrain ECS. Here a statistical method (including a backward selection process) is employed to achieve a better statistical understanding of the connections between four recently proposed emergent constraint metrics and individual feedbacks influencing ECS. The relationship between each metric and ECS is largely attributable tomore » a statistical connection with shortwave low cloud feedback, the leading cause of intermodel ECS spread. This result bolsters confidence in some of the metrics, which had assumed such a connection in the first place. Additional analysis is conducted with a few thousand artificial metrics that are randomly generated but are well correlated with ECS. The relationships between the contrived metrics and ECS can also be linked statistically to shortwave cloud feedback. Thus, any proposed or forthcoming ECS constraint based on the current generation of climate models should be viewed as a potential constraint on shortwave cloud feedback, and physical links with that feedback should be investigated to verify that the constraint is real. Additionally, any proposed ECS constraint should not be taken at face value since other factors influencing ECS besides shortwave cloud feedback could be systematically biased in the models.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, Xin; Hall, Alex; DeAngelis, Anthony M.
Differences among climate models in equilibrium climate sensitivity (ECS; the equilibrium surface temperature response to a doubling of atmospheric CO2) remain a significant barrier to the accurate assessment of societally important impacts of climate change. Relationships between ECS and observable metrics of the current climate in model ensembles, so-called emergent constraints, have been used to constrain ECS. Here a statistical method (including a backward selection process) is employed to achieve a better statistical understanding of the connections between four recently proposed emergent constraint metrics and individual feedbacks influencing ECS. The relationship between each metric and ECS is largely attributable tomore » a statistical connection with shortwave low cloud feedback, the leading cause of intermodel ECS spread. This result bolsters confidence in some of the metrics, which had assumed such a connection in the first place. Additional analysis is conducted with a few thousand artificial metrics that are randomly generated but are well correlated with ECS. The relationships between the contrived metrics and ECS can also be linked statistically to shortwave cloud feedback. Thus, any proposed or forthcoming ECS constraint based on the current generation of climate models should be viewed as a potential constraint on shortwave cloud feedback, and physical links with that feedback should be investigated to verify that the constraint is real. Additionally, any proposed ECS constraint should not be taken at face value since other factors influencing ECS besides shortwave cloud feedback could be systematically biased in the models.« less
76 FR 38072 - Airworthiness Directives; The Boeing Company Model 777 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-29
... above. This proposed AD would require repetitive detailed inspection and high frequency eddy current... high frequency eddy current (HFEC) inspection for cracks in the WCS web pockets of spanwise beams... = 160 frequency eddy current inspection per hour = $4,250 inspection cycle. airplanes x $4,250 of...
Pircher, Andreas; Treps, Lucas; Bodrug, Natalia; Carmeliet, Peter
2016-10-01
Atherosclerosis is a leading cause of morbidity and mortality in Western society. Despite improved insight into disease pathogenesis and therapeutic options, additional treatment strategies are required. Emerging evidence highlights the relevance of endothelial cell (EC) metabolism for angiogenesis, and indicates that EC metabolism is perturbed when ECs become dysfunctional to promote atherogenesis. In this review, we overview the latest insights on EC metabolism and discuss current knowledge on how atherosclerosis deregulates EC metabolism, and how maladaptation of deregulated EC metabolism can contribute to atherosclerosis progression. We will also highlight possible therapeutic avenues, based on targeting EC metabolism. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Impact of flavour variability on electronic cigarette use experience: an internet survey.
Farsalinos, Konstantinos E; Romagna, Giorgio; Tsiapras, Dimitris; Kyrzopoulos, Stamatis; Spyrou, Alketa; Voudris, Vassilis
2013-12-17
A major characteristic of the electronic cigarette (EC) market is the availability of a large number of different flavours. This has been criticised by the public health authorities, some of whom believe that diverse flavours will attract young users and that ECs are a gateway to smoking. At the same time, several reports in the news media mention that the main purpose of flavour marketing is to attract youngsters. The importance of flavourings and their patterns of use by EC consumers have not been adequately evaluated, therefore, the purpose of this survey was to examine and understand the impact of flavourings in the EC experience of dedicated users. A questionnaire was prepared and uploaded in an online survey tool. EC users were asked to participate irrespective of their current smoking status. Participants were divided according to their smoking status at the time of participation in two subgroups: former smokers and current smokers. In total, 4,618 participants were included in the analysis, with 4,515 reporting current smoking status. The vast majority (91.1%) were former smokers, while current smokers had reduced smoking consumption from 20 to 4 cigarettes per day. Both subgroups had a median smoking history of 22 years and had been using ECs for 12 months. On average they were using three different types of liquid flavours on a regular basis, with former smokers switching between flavours more frequently compared to current smokers; 69.2% of the former subgroup reported doing so on a daily basis or within the day. Fruit flavours were more popular at the time of participation, while tobacco flavours were more popular at initiation of EC use. On a scale from 1 (not at all important) to 5 (extremely important) participants answered that variability of flavours was "very important" (score = 4) in their effort to reduce or quit smoking. The majority reported that restricting variability will make ECs less enjoyable and more boring, while 48.5% mentioned that it would increase craving for cigarettes and 39.7% said that it would have been less likely for them to reduce or quit smoking. The number of flavours used was independently associated with smoking cessation. The results of this survey of dedicated users indicate that flavours are marketed in order to satisfy vapers' demand. They appear to contribute to both perceived pleasure and the effort to reduce cigarette consumption or quit smoking. Due to the fact that adoption of ECs by youngsters is currently minimal, it seems that implementing regulatory restrictions to flavours could cause harm to current vapers while no public health benefits would be observed in youngsters. Therefore, flavours variability should be maintained; any potential future risk for youngsters being attracted to ECs can be sufficiently minimized by strictly prohibiting EC sales in this population group.
In-service inspection methods for graphite-epoxy structures on commercial transport aircraft
NASA Technical Reports Server (NTRS)
Phelps, M. L.
1981-01-01
In-service inspection methods for graphite-epoxy composite structures on commercial transport aircraft are determined. Graphite/epoxy structures, service incurred defects, current inspection practices and concerns of the airline and manufacturers, and other related information were determind by survey. Based on this information, applicable inspection nondestructive inspection methods are evaluated and inspection techniques determined. Technology is developed primarily in eddy current inspection.
The Cannabinoid System and Pain
Woodhams, Stephen G.; Chapman, Victoria; Finn, David P.; Hohmann, Andrea G.; Neugebauer, Volker
2018-01-01
Chronic pain states are highly prevalent and yet poorly controlled by currently available analgesics, representing an enormous clinical, societal, and economic burden. Existing pain medications have significant limitations and adverse effects including tolerance, dependence, gastrointestinal dysfunction, cognitive impairment, and a narrow therapeutic window, making the search for novel analgesics ever more important. In this article, we review the role of an important endogenous pain control system, the endocannabinoid (EC) system, in the sensory, emotional, and cognitive aspects of pain. Herein, we briefly cover the discovery of the EC system and its role in pain processing pathways, before concentrating on three areas of current major interest in EC pain research; 1. Pharmacological enhancement of endocannabinoid activity (via blockade of EC metabolism or allosteric modulation of CB1 receptors); 2. The EC System and stress-induced modulation of pain; and 3. The EC system & medial prefrontal cortex (mPFC) dysfunction in pain states. Whilst we focus predominantly on the preclinical data, we also include extensive discussion of recent clinical failures of endocannabinoid-related therapies, the future potential of these approaches, and important directions for future research on the EC system and pain. PMID:28625720
Batur, Pelin; Kransdorf, Lisa N; Casey, Petra M
2016-06-01
Emergency contraception (EC) may help prevent pregnancy in various circumstances, such as contraceptive method failure, unprotected sexual intercourse, or sexual assault, yet it remains underused. There are 4 approved EC options in the United States. Although ulipristal acetate requires a provider's prescription, oral levonorgestrel (LNG) is available over the counter for women of all ages. The most effective method of EC is the copper intrauterine device, which can be left in place for up to 10 years for efficacious, cost-effective, hormone-free, and convenient long-term primary contraception. Ulipristal acetate tends to be more efficacious in pregnancy prevention than is LNG, especially when taken later than 72 hours postcoitus. The mechanism of action of oral EC is delay of ovulation, and current evidence reveals that it is ineffective postovulation. Women who weigh more than 75 kg or have a body mass index greater than 25 kg/m(2) may have a higher risk of unintended pregnancy when using oral LNG EC; therefore, ulipristal acetate or copper intrauterine devices are preferable in this setting. Providers are often unaware of the range of EC options or are unsure of how to counsel patients regarding the access and use of EC. This article critically reviews current EC literature, summarizes recommendations, and provides guidance for counseling women about EC. Useful tips for health care providers are provided, with a focus on special populations, including breast-feeding women and those transitioning to long-term contraception after EC use. When treating women of reproductive age, clinicians should be prepared to counsel them about EC options, provide EC appropriately, and, if needed, refer for EC in a timely manner. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
77 FR 64709 - Airworthiness Directives; MD Helicopters, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... visual inspection, and if necessary, an eddy current inspection of the main rotor lower hub assembly... specifies an initial 100-hour and recurring 300-hour visual and eddy current inspections of the lower hub... a total cost per helicopter of $85 and a total cost of $1,020 for the fleet. Eddy current inspecting...
Robotic NDE inspection of advanced solid rocket motor casings
NASA Technical Reports Server (NTRS)
Mcneelege, Glenn E.; Sarantos, Chris
1994-01-01
The Advanced Solid Rocket Motor program determined the need to inspect ASRM forgings and segments for potentially catastrophic defects. To minimize costs, an automated eddy current inspection system was designed and manufactured for inspection of ASRM forgings in the initial phases of production. This system utilizes custom manipulators and motion control algorithms and integrated six channel eddy current data acquisition and analysis hardware and software. Total system integration is through a personal computer based workcell controller. Segment inspection demands the use of a gantry robot for the EMAT/ET inspection system. The EMAT/ET system utilized similar mechanical compliancy and software logic to accommodate complex part geometries. EMAT provides volumetric inspection capability while eddy current is limited to surface and near surface inspection. Each aspect of the systems are applicable to other industries, such as, inspection of pressure vessels, weld inspection, and traditional ultrasonic inspection applications.
ToxCast HTS Assay Development and Retrofitting: Strategies ...
A presentation to EC JRC partners on new ToxCast HTS assay methods and strategies to address current limitations to HTS methods Slide presentation to EC JRC partners on new ToxCast HTS assay methods and strategies to address current limitations to HTS methods.
2016 Research Final Presentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koskelo, EliseAnne Corinne
These are slides which show an example of research at Los Alamos National Laboratory done by E.C. Koskelo to show college professors in the hopes of earning a research position or fellowship position. In summary, this researcher developed a new in-situ technique for the inspection of additively manufactured parts, created an algorithm which can correct "skewed" scans of angular parts/taken at oblique angles, and used AWS to detect hidden defects and thickness changes in aerospace composites.
76 FR 41662 - Airworthiness Directives; MD Helicopters, Inc. Model MD900 Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... different compliance time; adds an eddy current inspection; retains the requirement to replace a cracked... and recurring 300-hour visual and eddy current inspections of the lower hub for a crack and, if there... AD requires a visual inspection, and if necessary, an eddy current inspection of the lower hub for a...
Status of Europe's contribution to the ITER EC system
NASA Astrophysics Data System (ADS)
Albajar, F.; Aiello, G.; Alberti, S.; Arnold, F.; Avramidis, K.; Bader, M.; Batista, R.; Bertizzolo, R.; Bonicelli, T.; Braunmueller, F.; Brescan, C.; Bruschi, A.; von Burg, B.; Camino, K.; Carannante, G.; Casarin, V.; Castillo, A.; Cauvard, F.; Cavalieri, C.; Cavinato, M.; Chavan, R.; Chelis, J.; Cismondi, F.; Combescure, D.; Darbos, C.; Farina, D.; Fasel, D.; Figini, L.; Gagliardi, M.; Gandini, F.; Gantenbein, G.; Gassmann, T.; Gessner, R.; Goodman, T. P.; Gracia, V.; Grossetti, G.; Heemskerk, C.; Henderson, M.; Hermann, V.; Hogge, J. P.; Illy, S.; Ioannidis, Z.; Jelonnek, J.; Jin, J.; Kasparek, W.; Koning, J.; Krause, A. S.; Landis, J. D.; Latsas, G.; Li, F.; Mazzocchi, F.; Meier, A.; Moro, A.; Nousiainen, R.; Purohit, D.; Nowak, S.; Omori, T.; van Oosterhout, J.; Pacheco, J.; Pagonakis, I.; Platania, P.; Poli, E.; Preis, A. K.; Ronden, D.; Rozier, Y.; Rzesnicki, T.; Saibene, G.; Sanchez, F.; Sartori, F.; Sauter, O.; Scherer, T.; Schlatter, C.; Schreck, S.; Serikov, A.; Siravo, U.; Sozzi, C.; Spaeh, P.; Spichiger, A.; Strauss, D.; Takahashi, K.; Thumm, M.; Tigelis, I.; Vaccaro, A.; Vomvoridis, J.; Tran, M. Q.; Weinhorst, B.
2015-03-01
The electron cyclotron (EC) system of ITER for the initial configuration is designed to provide 20MW of RF power into the plasma during 3600s and a duty cycle of up to 25% for heating and (co and counter) non-inductive current drive, also used to control the MHD plasma instabilities. The EC system is being procured by 5 domestic agencies plus the ITER Organization (IO). F4E has the largest fraction of the EC procurements, which includes 8 high voltage power supplies (HVPS), 6 gyrotrons, the ex-vessel waveguides (includes isolation valves and diamond windows) for all launchers, 4 upper launchers and the main control system. F4E is working with IO to improve the overall design of the EC system by integrating consolidated technological advances, simplifying the interfaces, and doing global engineering analysis and assessments of EC heating and current drive physics and technology capabilities. Examples are the optimization of the HVPS and gyrotron requirements and performance relative to power modulation for MHD control, common qualification programs for diamond window procurements, assessment of the EC grounding system, and the optimization of the launcher steering angles for improved EC access. Here we provide an update on the status of Europe's contribution to the ITER EC system, and a summary of the global activities underway by F4E in collaboration with IO for the optimization of the subsystems.
Access to Emergency Contraception in the Over-the-Counter Era
Cleland, Kelly; Bass, Jamie; Doci, Florida; Foster, Angel M.
2016-01-01
Introduction After years of complex regulatory changes, levonorgestrel emergency contraception (LNG EC) is now approved for unrestricted sale in the US. Timely access to EC pills is critical because they are more likely to work the sooner they are taken. This study assesses whether LNG EC is sold in accordance with current Food and Drug Administration regulations. Methods We distributed an online questionnaire through an EC-focused listserv for reproductive health professionals, asking data collectors to visit local stores and document product names, price, over-the-counter (OTC) shelf availability, and misinformation about age restrictions. We used Chi-square analysis to assess bivariate associations and t-tests and Wilcoxon rank-sum tests to determine differences in means. Results We collected information about 220 stores. The majority (65%) stocked EC on OTC shelves, although only 22% of these displayed it without a locked security enclosure. Chain pharmacies were more likely to shelf-stock EC than independent pharmacies (77% vs 5%; p=0.000), but variation existed among stores within the same chain. Among stores that were asked, 40% incorrectly reported an age restriction for non-prescription purchase of LNG EC, while 95% correctly reported that men can buy LNG EC. The average price of branded and generic LNG EC was $49.64 and $40.05, respectively. Conclusion Changes in the regulatory status of LNG EC have resulted in widespread confusion about how EC can be sold, and its high price contributes to access barriers. Retailers should ensure that consumers can access LNG EC quickly and easily by stocking the product on OTC shelves and educating staff about current regulations. PMID:27682018
Spanjer, M; Stroka, J; Patel, S; Buechler, S; Pittet, A; Barel, S
2001-06-01
Mycotoxins contamination is highly non-uniformly distributed as is well recog-nized by the EC, by not only setting legal limits in a series of commodities, but also schedule a sampling plan that takes this heterogeneity into account. In practice however, it turns out that it is very difficult to carry out this sampling plan in a harmonised way. Applying the sampling plan to a container filled with pallets of bags (i.e. with nuts or coffee beans) varies from very laborious to almost impossible. The presented non-destructive automated method to sample bulk food could help to overcome these practical problems and to enforcing of EC directives. It is derived from a tested and approved technology for detection of illicit substances in security applications. It has capability to collect and iden-tify ultra trace contaminants, i.e. from a fingerprint of chemical substance in a bulk of goods, a cargo pallet load (~ 1000 kg) with boxes and commodities.The technology, patented for explosives detection, uses physical and chemistry processes for excitation and remote rapid enhanced release of contaminant residues, vapours and particulate, of the inner/outer surfaces of inspected bulk and collect them on selective probes. The process is automated, takes only 10 minutes, is non-destructive and the bulk itself remains unharmed. The system design is based on applicable international regulations for shipped cargo hand-ling and transportation by road, sea and air. After this process the pallet can be loaded on a truck, ship or plane. Analysis can be carried out before the cargo leaves the place of shipping. The potent application of this technology for myco-toxins detection, has been demonstrated by preliminary feasibility experiments. Aflatoxins were detected in pistachios and ochratoxin A in green coffee beans bulk. Both commodities were naturally contaminated, priory found and confirm-ed by common methods as used at routine inspections. Once the contaminants are extracted from a bulk shipment, an appropriate existing analytical method, i.e. a CEN method, can be used to measure the mycotoxins.The system, routinely in use for explosives detection, was able to screen bulk food and feed for mycotoxins, through non-destructive automated sampling of a whole batch/lot/sublot of commodities. The opportunity to sample a whole bulk would provide more effective tools for inspection at seaports, production facili-ties and distri-bution points. It will advance the current process of myco-toxins check because: (i) Checks will be automated and harmonized, (ii) Checks will be non-destructive, (iii) Checks will be faster and allow a greater amount of bulk commodities to be inspected and (iv) The ability to check, with automated equipment, larger portions of lots of a shipment will increase the probability to detect the heterogeneous mycotoxins contamination in bulk foods. The poster provides some results of feasibility experiments indicating the capability of this technology for inspection of commodities bulks for the detection of mycotoxins, at legal limits, in naturally contaminated food.
ERIC Educational Resources Information Center
Dutt, James S.
Although electronic commerce (EC) has been a reality for more than two decades, interest in EC has exploded within the past three years due to the increased business use of the Internet and the World Wide Web. While companies are increasingly looking for individuals with knowledge of and/or a background in EC, they are finding that most…
Wang, Xiansheng; Ni, Jiaheng; Pang, Shuo; Li, Ying
2017-04-01
A electrocoagulation (EC)/peanut shell (PS) adsorption coupling technique was studied for the removal of malachite green (MG) in our present work. The addition of an appropriate PS dosage (5 g/L) resulted in remarkable increase in the removal efficiency of MG at lower current density and shorter operating time compared with the conventional EC process. The effect of current density, pH of MG solution, dosage of PS and initial concentration of MG were also investigated. The maximum removal efficiency of MG was 98% under optimum conditions in 5 min. And it was 23% higher than that in EC process. Furthermore, the unit energy demand (UED) and the unit electrode material demand (UEMD) were calculated and discussed. The results demonstrated that the EC/PS adsorption coupling method achieved a reduction of 94% UED and UEMD compared with EC process.
Eddy-Current Inspection Of Tab Seals On Beverage Cans
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph
1994-01-01
Eddy-current inspection system monitors tab seals on beverage cans. Device inspects all cans at usual production rate of 1,500 to 2,000 cans per minute. Automated inspection of all units replaces visual inspection by microscope aided by mass spectrometry. System detects defects in real time. Sealed cans on conveyor pass near one of two coils in differential eddy-current probe. Other coil in differential eddy-current probe positioned near stationary reference can on which tab seal is known to be of acceptable quality. Signal of certain magnitude at output of probe indicates defective can, automatically ejected from conveyor.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-04
... AD using a drawdown plan that includes a borescope inspection (BSI) or eddy current inspection (ECI... inspection (BSI) or eddy current inspection (ECI) of the disk rim according to the following schedule: (i...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... option is to conduct an eddy current inspection and the other option is to conduct a visual inspection... eddy current inspection, at an average labor rate of $85 per work hour. Required parts would cost about... using either an eddy current inspection in accordance with paragraphs B.(1)(a) through B.(1)(o) or using...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Neeraj; Büchner, Jörg; Max Planck Institute for Solar System Research, Justus-Von-Liebig-Weg-3, Göttingen
Nonlinear evolution of three dimensional electron shear flow instabilities of an electron current sheet (ECS) is studied using electron-magnetohydrodynamic simulations. The dependence of the evolution on current sheet thickness is examined. For thin current sheets (half thickness =d{sub e}=c/ω{sub pe}), tearing mode instability dominates. In its nonlinear evolution, it leads to the formation of oblique current channels. Magnetic field lines form 3-D magnetic spirals. Even in the absence of initial guide field, the out-of-reconnection-plane magnetic field generated by the tearing instability itself may play the role of guide field in the growth of secondary finite-guide-field instabilities. For thicker current sheetsmore » (half thickness ∼5 d{sub e}), both tearing and non-tearing modes grow. Due to the non-tearing mode, current sheet becomes corrugated in the beginning of the evolution. In this case, tearing mode lets the magnetic field reconnect in the corrugated ECS. Later thick ECS develops filamentary structures and turbulence in which reconnection occurs. This evolution of thick ECS provides an example of reconnection in self-generated turbulence. The power spectra for both the thin and thick current sheets are anisotropic with respect to the electron flow direction. The cascade towards shorter scales occurs preferentially in the direction perpendicular to the electron flow.« less
Effect of Carbon Nanotubes Upon Emissions From Cutting and Sanding Carbon Fiber-Epoxy Composites
Heitbrink, William A.; Lo, Li-Ming
2015-01-01
Carbon nanotubes (CNTs) are being incorporated into structural composites to enhance material strength. During fabrication or repair activities, machining nanocomposites may release CNTs into the workplace air. An experimental study was conducted to evaluate the emissions generated by cutting and sanding on three types of epoxy-composite panels: Panel A containing graphite fibers, Panel B containing graphite fibers and carbon-based mat, and Panel C containing graphite fibers, carbon-based mat, and multi-walled CNTs. Aerosol sampling was conducted with direct-reading instruments, and filter samples were collected for measuring elemental carbon (EC) and fiber concentrations. Our study results showed that cutting Panel C with a band saw did not generate detectable emissions of fibers inspected by transmission electron microscopy but did increase the particle mass, number, and EC emission concentrations by 20% to 80% compared to Panels A and B. Sanding operation performed on two Panel C resulted in fiber emission rates of 1.9×108 and 2.8×106 fibers per second (f/s), while no free aerosol fibers were detected from sanding Panels A and B containing no CNTs. These free CNT fibers may be a health concern. However, the analysis of particle and EC concentrations from these same samples cannot clearly indicate the presence of CNTs, because extraneous aerosol generation from machining the composite epoxy material increased the mass concentrations of the EC. PMID:26478716
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-04
... detailed and eddy current inspections to detect cracks and corrosion of certain midspar fuse pins, and... addition to longitudinal cracks. In addition, eddy current inspection of the midspar fuse pins in..., 311T3102-3, 311T3102-4, 311T2102-1 or 311T2102-2: Do a detailed inspection and an eddy current inspection...
1988-08-31
behavior/operational goals so tnat corrective action may be taken. Data produced by the IS activities form the basis for design/--1pport trade-offs while...rt7L:EC T Ef Approved for public release; distribution unlimited c R SOUTHWEST RESEARCH INSTITUTE SAN ANTONIO HOUSTON I SECURITY CLASSIFICATION OF THIS...DISTRIBUTION/AVAILABLITY OF REPORT Approved for public release; 2b. DECLASSIFICATION I DOWNGRADING SCHEDULE distribution unlimited 4 PERFORMING ORGANIZATION
Eddy-Current Inspection Of Graphite-Fiber Composites
NASA Technical Reports Server (NTRS)
Workman, G. L.; Bryson, C. C.
1993-01-01
NASA technical memorandum describes initial research on, and proposed development of, automated system for nondestructive eddy-current inspection of parts made of graphite-fiber/epoxy-matrix composite materials. Sensors in system E-shaped or U-shaped eddy-current probes like those described in "Eddy-Current Probes For Inspecting Graphite-Fiber Composites" (MFS-26129).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... doing internal eddy current inspections, or repairing the crack. As an alternative to the external eddy current inspections, the AD provides for internal eddy current and detailed inspections for cracks in the... 5, 2011, we issued Emergency AD 2011-08-51, which requires repetitive external eddy current...
Effect of Ionic Diffusion on Extracellular Potentials in Neural Tissue
Halnes, Geir; Mäki-Marttunen, Tuomo; Keller, Daniel; Pettersen, Klas H.; Andreassen, Ole A.
2016-01-01
Recorded potentials in the extracellular space (ECS) of the brain is a standard measure of population activity in neural tissue. Computational models that simulate the relationship between the ECS potential and its underlying neurophysiological processes are commonly used in the interpretation of such measurements. Standard methods, such as volume-conductor theory and current-source density theory, assume that diffusion has a negligible effect on the ECS potential, at least in the range of frequencies picked up by most recording systems. This assumption remains to be verified. We here present a hybrid simulation framework that accounts for diffusive effects on the ECS potential. The framework uses (1) the NEURON simulator to compute the activity and ionic output currents from multicompartmental neuron models, and (2) the electrodiffusive Kirchhoff-Nernst-Planck framework to simulate the resulting dynamics of the potential and ion concentrations in the ECS, accounting for the effect of electrical migration as well as diffusion. Using this framework, we explore the effect that ECS diffusion has on the electrical potential surrounding a small population of 10 pyramidal neurons. The neural model was tuned so that simulations over ∼100 seconds of biological time led to shifts in ECS concentrations by a few millimolars, similar to what has been seen in experiments. By comparing simulations where ECS diffusion was absent with simulations where ECS diffusion was included, we made the following key findings: (i) ECS diffusion shifted the local potential by up to ∼0.2 mV. (ii) The power spectral density (PSD) of the diffusion-evoked potential shifts followed a 1/f2 power law. (iii) Diffusion effects dominated the PSD of the ECS potential for frequencies up to several hertz. In scenarios with large, but physiologically realistic ECS concentration gradients, diffusion was thus found to affect the ECS potential well within the frequency range picked up in experimental recordings. PMID:27820827
Effect of Ionic Diffusion on Extracellular Potentials in Neural Tissue.
Halnes, Geir; Mäki-Marttunen, Tuomo; Keller, Daniel; Pettersen, Klas H; Andreassen, Ole A; Einevoll, Gaute T
2016-11-01
Recorded potentials in the extracellular space (ECS) of the brain is a standard measure of population activity in neural tissue. Computational models that simulate the relationship between the ECS potential and its underlying neurophysiological processes are commonly used in the interpretation of such measurements. Standard methods, such as volume-conductor theory and current-source density theory, assume that diffusion has a negligible effect on the ECS potential, at least in the range of frequencies picked up by most recording systems. This assumption remains to be verified. We here present a hybrid simulation framework that accounts for diffusive effects on the ECS potential. The framework uses (1) the NEURON simulator to compute the activity and ionic output currents from multicompartmental neuron models, and (2) the electrodiffusive Kirchhoff-Nernst-Planck framework to simulate the resulting dynamics of the potential and ion concentrations in the ECS, accounting for the effect of electrical migration as well as diffusion. Using this framework, we explore the effect that ECS diffusion has on the electrical potential surrounding a small population of 10 pyramidal neurons. The neural model was tuned so that simulations over ∼100 seconds of biological time led to shifts in ECS concentrations by a few millimolars, similar to what has been seen in experiments. By comparing simulations where ECS diffusion was absent with simulations where ECS diffusion was included, we made the following key findings: (i) ECS diffusion shifted the local potential by up to ∼0.2 mV. (ii) The power spectral density (PSD) of the diffusion-evoked potential shifts followed a 1/f2 power law. (iii) Diffusion effects dominated the PSD of the ECS potential for frequencies up to several hertz. In scenarios with large, but physiologically realistic ECS concentration gradients, diffusion was thus found to affect the ECS potential well within the frequency range picked up in experimental recordings.
New concepts for an old problem: the diagnosis of endometrial hyperplasia
Sanderson, Peter A.; Critchley, Hilary O.D.; Williams, Alistair R.W.; Arends, Mark J.; Saunders, Philippa T.K.
2017-01-01
Abstract BACKGROUND Endometrial hyperplasia (EH) is a uterine pathology representing a spectrum of morphological endometrial alterations. It is predominantly characterized by an increase in the endometrial gland-to-stroma ratio when compared to normal proliferative endometrium. The clinical significance of EH lies in the associated risk of progression to endometrioid endometrial cancer (EC) and ‘atypical’ forms of EH are regarded as premalignant lesions. Traditional histopathological classification systems for EH exhibit wide and varying degrees of diagnostic reproducibility and, as a consequence, standardized patient management can be challenging. OBJECTIVE AND RATIONALE EC is the most common gynaecological malignancy in developed countries. The incidence of EC is rising, with alarming increases described in the 40–44-year-old age group. This review appraises the current EH classification systems used to stratify women at risk of malignant progression to EC. In addition, we summarize the evidence base regarding the use of immunohistochemical biomarkers for EH and discuss an emerging role for genomic analysis. SEARCH METHODS PubMed, Medline and the Cochrane Database were searched for original peer-reviewed primary and review articles, from January 2000 to January 2016. The following search terms were used: ‘endometrial hyperplasia’, ‘endometrial intraepithelial neoplasia’, ‘atypical hyperplasia’, ‘complex atypical hyperplasia’, ‘biomarker’, ‘immunohistochemistry’, ‘progression’, ‘genomic’, ‘classification’ and ‘stratification’. OUTCOMES Recent changes to EH classification reflect our current understanding of the genesis of endometrioid ECs. The concept of endometrial intraepithelial neoplasia (EIN) as a mutationally activated, monoclonal pre-malignancy represents a fundamental shift from the previously held notion that unopposed oestrogenic stimulation causes ever-increasing hyperplastic proliferation, with accumulating cytological atypia that imperceptibly leads to the development of endometrioid EC. Our review highlights several key biomarker candidates that have been described as both diagnostic tools for EH and markers of progression to EC. We propose that, moving forwards, a ‘panel’ approach of combinations of the immunohistochemical biomarkers described in this review may be more informative since no single candidate can currently fill the entire role. WIDER IMPLICATIONS EC has historically been considered a predominantly postmenopausal disease. Owing in part to the current unprecedented rates of obesity, we are starting to see signs of a shift towards a rising incidence of EC amongst pre- and peri-menopausal woman. This creates unique challenges both diagnostically and therapeutically. Furthering our understanding of the premalignant stages of EC development will allow us to pursue earlier diagnosis and facilitate appropriate stratification of women at risk of developing EC, permitting timely and appropriate therapeutic interventions. PMID:27920066
New concepts for an old problem: the diagnosis of endometrial hyperplasia.
Sanderson, Peter A; Critchley, Hilary O D; Williams, Alistair R W; Arends, Mark J; Saunders, Philippa T K
2017-03-01
Endometrial hyperplasia (EH) is a uterine pathology representing a spectrum of morphological endometrial alterations. It is predominantly characterized by an increase in the endometrial gland-to-stroma ratio when compared to normal proliferative endometrium. The clinical significance of EH lies in the associated risk of progression to endometrioid endometrial cancer (EC) and 'atypical' forms of EH are regarded as premalignant lesions. Traditional histopathological classification systems for EH exhibit wide and varying degrees of diagnostic reproducibility and, as a consequence, standardized patient management can be challenging. EC is the most common gynaecological malignancy in developed countries. The incidence of EC is rising, with alarming increases described in the 40-44-year-old age group. This review appraises the current EH classification systems used to stratify women at risk of malignant progression to EC. In addition, we summarize the evidence base regarding the use of immunohistochemical biomarkers for EH and discuss an emerging role for genomic analysis. PubMed, Medline and the Cochrane Database were searched for original peer-reviewed primary and review articles, from January 2000 to January 2016. The following search terms were used: 'endometrial hyperplasia', 'endometrial intraepithelial neoplasia', 'atypical hyperplasia', 'complex atypical hyperplasia', 'biomarker', 'immunohistochemistry', 'progression', 'genomic', 'classification' and 'stratification'. Recent changes to EH classification reflect our current understanding of the genesis of endometrioid ECs. The concept of endometrial intraepithelial neoplasia (EIN) as a mutationally activated, monoclonal pre-malignancy represents a fundamental shift from the previously held notion that unopposed oestrogenic stimulation causes ever-increasing hyperplastic proliferation, with accumulating cytological atypia that imperceptibly leads to the development of endometrioid EC. Our review highlights several key biomarker candidates that have been described as both diagnostic tools for EH and markers of progression to EC. We propose that, moving forwards, a 'panel' approach of combinations of the immunohistochemical biomarkers described in this review may be more informative since no single candidate can currently fill the entire role. EC has historically been considered a predominantly postmenopausal disease. Owing in part to the current unprecedented rates of obesity, we are starting to see signs of a shift towards a rising incidence of EC amongst pre- and peri-menopausal woman. This creates unique challenges both diagnostically and therapeutically. Furthering our understanding of the premalignant stages of EC development will allow us to pursue earlier diagnosis and facilitate appropriate stratification of women at risk of developing EC, permitting timely and appropriate therapeutic interventions. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology.
77 FR 68050 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
... repetitive [high frequency eddy current] inspections [for cracks] of certain crossbeams including those... actions have already been done. (g) Repetitive High Frequency Eddy Current Inspections (1) For airplanes... AD, whichever occurs first. FedEx stated that the current repetitive inspection interval is ten times...
Automated Eddy Current Inspection on Space Shuttle Hardware
NASA Technical Reports Server (NTRS)
Hartmann, John; Felker, Jeremy
2007-01-01
Over the life time of the Space Shuttle program, metal parts used for the Reusable Solid Rocket Motors (RSRMs) have been nondestructively inspected for cracks and surface breaking discontinuities using magnetic particle (steel) and penetrant methods. Although these inspections adequately screened for critical sized cracks in most regions of the hardware, it became apparent after detection of several sub-critical flaws that the processes were very dependent on operator attentiveness and training. Throughout the 1990's, eddy current inspections were added to areas that had either limited visual access or were more fracture critical. In the late 1990's. a project was initiated to upgrade NDE inspections with the overall objective of improving inspection reliability and control. An automated eddy current inspection system was installed in 2001. A figure shows one of the inspection bays with the robotic axis of the system highlighted. The system was programmed to inspect the various case, nozzle, and igniter metal components that make up an RSRM. both steel and aluminum. For the past few years, the automated inspection system has been a part of the baseline inspection process for steel components. Although the majority of the RSRM metal part inventory ts free of detectable surface flaws, a few small, sub-critical manufacturing defects have been detected with the automated system. This paper will summarize the benefits that have been realized with the current automated eddy current system, as well as the flaws that have been detected.
77 FR 2266 - Request for Extension and Revision of a Currently Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-17
... DEPARTMENT OF AGRICULTURE Grain Inspection, Packers and Stockyards Administration Request for Extension and Revision of a Currently Approved Information Collection AGENCY: Grain Inspection, Packers and...- year extension and revision of a currently approved information collection for ``Export Inspection and...
Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda
2015-04-01
The screening laboratory has a critical role in the post-transfusion safety. The success of its targets and efficiency depends on the management system used. Even though the European Union directive 2002/98/EC requires a quality management system in blood establishments, its requirements for screening laboratories are generic. Complementary approaches are needed to implement a quality management system focused on screening laboratories. This article briefly discusses the current good manufacturing practices and good laboratory practices, as well as the trends in quality management system standards. ISO 9001 is widely accepted in some European Union blood establishments as the quality management standard, however this is not synonymous of its successful application. The ISO "risk-based thinking" is interrelated with the quality risk-management process of the EuBIS "Standards and criteria for the inspection of blood establishments". ISO 15189 should be the next step on the quality assurance of a screening laboratory, since it is focused on medical laboratory. To standardize the quality management systems in blood establishments' screening laboratories, new national and European claims focused on technical requirements following ISO 15189 is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
78 FR 15281 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-11
... horizontal stabilizer. This AD requires repetitive high frequency eddy current (HFEC) inspections for... repetitive high frequency eddy current (HFEC) inspections for cracking of the left and right rib hinge... high frequency eddy current (HFEC) inspection for cracking of the left and right rib hinge bearing lugs...
78 FR 46536 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... eddy current inspection of the fastener holes for defects and repair if necessary. We are proposing... also includes doing a high frequency eddy current inspection of the fastener holes for defects and... frequency eddy current inspection of the fastener holes for defects and all applicable repairs, in...
ERP Correlates of Effortful Control in Children with Varying Levels of ADHD Symptoms
ERIC Educational Resources Information Center
Wiersema, Jan R.; Roeyers, Herbert
2009-01-01
As effortful control (EC), the self-regulation aspect of temperament, has been argued to play a key role in the normal and psychopathological course of development, research adding to the construct validity of EC is needed. In the current study, interrelations between the temperament construct of EC and the efficiency of the executive attention…
78 FR 4042 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... provides an option for a high frequency eddy current inspection for cracking of the critical fastener holes... for a high frequency eddy current inspection for cracking of the critical fastener holes, and repair..., August 9, 2007)), do a high frequency eddy current (HFEC) inspection for cracking of the four critical...
77 FR 5724 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-06
... proposed AD would require repetitive low frequency eddy current inspections of the forward fuselage butt... repetitive [low frequency eddy current] inspections of the forward fuselage butt joints for cracks and, when... effective date of this AD, whichever occurs later, do a low frequency eddy current inspection of the forward...
77 FR 37788 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
... Model F.28 Mark 0100 airplane. This AD requires repetitive low frequency eddy current inspections of the... described above, this [EASA] AD requires repetitive [low frequency eddy current] inspections of the forward... eddy current inspection of the forward fuselage butt-joints for cracks, in accordance with the...
Archer, Edward; Petrie, Bruce; Kasprzyk-Hordern, Barbara; Wolfaardt, Gideon M
2017-05-01
A large number of emerging contaminants (ECs) are known to persist in surface waters, and create pressure on wastewater treatment works (WWTW) for their effective removal. Although a large database for the levels of these pollutants in water systems exist globally, there is still a lack in the correlation of the levels of these pollutants with possible long-term adverse health effects in wildlife and humans, such as endocrine disruption. The current study detected a total of 55 ECs in WWTW influent surface water, 41 ECs in effluent, and 40 ECs in environmental waters located upstream and downstream of the plant. A list of ECs persisted through the WWTW process, with 28% of all detected ECs removed by less than 50%, and 18% of all ECs were removed by less than 25%. Negative mass balances of some pharmaceuticals and metabolites were observed within the WWTW, suggesting possible back-transformation of ECs during wastewater treatment. Three parental illicit drug compounds were detected within the influent of the WWTW, with concentrations ranging between 27.6 and 147.0 ng L -1 for cocaine, 35.6-120.6 ng L -1 for mephedrone, and 270.9-450.2 ng L -1 for methamphetamine. The related environmental risks are also discussed for some ECs, with particular reference to their ability to disrupt endocrine systems. The current study propose the potential of the pharmaceuticals carbamazepine, naproxen, diclofenac and ibuprofen to be regarded as priority ECs for environmental monitoring due to their regular detection and persistence in environmental waters and their possible contribution towards adverse health effects in humans and wildlife. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sonkusare, Swapnil K; Dalsgaard, Thomas; Bonev, Adrian D; Nelson, Mark T
2016-06-15
Increase in endothelial cell (EC) calcium activates calcium-sensitive intermediate and small conductance potassium (IK and SK) channels, thereby causing hyperpolarization and endothelium-dependent vasodilatation. Endothelial cells express inward rectifier potassium (Kir) channels, but their role in endothelium-dependent vasodilatation is not clear. In the mesenteric arteries, only ECs, but not smooth muscle cells, displayed Kir currents that were predominantly mediated by the Kir2.1 isoform. Endothelium-dependent vasodilatations in response to muscarinic receptor, TRPV4 (transient receptor potential vanilloid 4) channel and IK/SK channel agonists were highly attenuated by Kir channel inhibitors and by Kir2.1 channel knockdown. These results point to EC Kir channels as amplifiers of vasodilatation in response to increases in EC calcium and IK/SK channel activation and suggest that EC Kir channels could be targeted to treat endothelial dysfunction, which is a hallmark of vascular disorders. Endothelium-dependent vasodilators, such as acetylcholine, increase intracellular Ca(2+) through activation of transient receptor potential vanilloid 4 (TRPV4) channels in the plasma membrane and inositol trisphosphate receptors in the endoplasmic reticulum, leading to stimulation of Ca(2+) -sensitive intermediate and small conductance K(+) (IK and SK, respectively) channels. Although strong inward rectifier K(+) (Kir) channels have been reported in the native endothelial cells (ECs) their role in EC-dependent vasodilatation is not clear. Here, we test the idea that Kir channels boost the EC-dependent vasodilatation of resistance-sized arteries. We show that ECs, but not smooth muscle cells, of small mesenteric arteries have Kir currents, which are substantially reduced in EC-specific Kir2.1 knockdown (EC-Kir2.1(-/-) ) mice. Elevation of extracellular K(+) to 14 mm caused vasodilatation of pressurized arteries, which was prevented by endothelial denudation and Kir channel inhibitors (Ba(2+) , ML-133) or in the arteries from EC-Kir2.1(-/-) mice. Potassium-induced dilatations were unaffected by inhibitors of TRPV4, IK and SK channels. The Kir channel blocker, Ba(2+) , did not affect currents through TRPV4, IK or SK channels. Endothelial cell-dependent vasodilatations in response to activation of muscarinic receptors, TRPV4 channels or IK/SK channels were reduced, but not eliminated, by Kir channel inhibitors or EC-Kir2.1(-/-) . In angiotensin II-induced hypertension, the Kir channel function was not altered, although the endothelium-dependent vasodilatation was severely impaired. Our results support the concept that EC Kir2 channels boost vasodilatory signals that are generated by Ca(2+) -dependent activation of IK and SK channels. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Eddy current inspection of graphite fiber components
NASA Technical Reports Server (NTRS)
Workman, G. L.; Bryson, C. C.
1990-01-01
The recognition of defects in materials properties still presents a number of problems for nondestructive testing in aerospace systems. This project attempts to utilize current capabilities in eddy current instrumentation, artificial intelligence, and robotics in order to provide insight into defining geometrical aspects of flaws in composite materials which are capable of being evaluated using eddy current inspection techniques. The unique capabilities of E-probes and horseshoe probes for inspecting probes for inspecting graphite fiber materials were evaluated and appear to hold great promise once the technology development matures. The initial results are described of modeling eddy current interactions with certain flaws in graphite fiber samples.
78 FR 73457 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-06
... frequency eddy current inspections for cracking of the tension tie at BS 760 or 780, as applicable, and do... ties, including doing an open-hole high frequency eddy current inspection for cracks, as applicable...) and paragraph (i) of this AD, but not as AMOCs for the high frequency eddy current inspections...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-21
... specifies a bolt hole eddy current inspection to verify the cracking. The corrective actions for cracking... specified in paragraph (k) of this AD, do eddy current non-destructive inspections (NDI) and detailed... secondary eddy current inspection to detect cracking of fastener holes with suspected crack indications; in...
77 FR 18963 - Airworthiness Directives; MD Helicopters, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-29
...) Model MD900 helicopters. The existing AD requires a visual inspection, and if necessary, an eddy current... with an airworthy lower hub. If there is no crack as a result of the visual inspection, eddy current... nondestructive eddy current inspection of the lower hub. That AD was prompted by cracks found on four lower hubs...
Breshears, J.; Sharma, M.; Anderson, N.R.; Rashid, S.; Leuthardt, E.C.
2010-01-01
Objective Traditional electrocortical stimulation (ECS) mapping is limited by the lengthy serial investigation (one location at a time) and the risk of afterdischarges in localizing eloquent cortex. Electrocorticographic frequency alteration mapping (EFAM) allows the parallel investigation of many cortical sites in much less time and with no risk of afterdischarges because of its passive nature. We examined its use with ECS in the context of language mapping during an awake craniotomy for a tumor resection. Clinical Presentation The patient was a 61-year-old right-handed Caucasian male who presented with headache and mild aphasia. Imaging demonstrated a 3-cm cystic mass in the posterior temporal-parietal lobe. The patient underwent an awake craniotomy for the mapping of his speech cortex and resection of the mass. Intervention Using a 32-contact electrode array, electrocorticographic signals were recorded from the exposed cortex as the patient participated in a 3-min screening task involving active (patient naming visually presented words) and rest (patient silent) conditions. A spectral comparison of the 2 conditions revealed specific cortical locations associated with activation during speech. The patient was then widely mapped using ECS. Three of 4 sites identified by ECS were also identified passively and in parallel by EFAM, 2 with statistical significance and the third by qualitative inspection. Conclusion EFAM was technically achieved in an awake craniotomy patient and had good concordance with ECS mapping. Because it poses no risk of afterdischarges and offers substantial time savings, EFAM holds promise for future development as an adjunct intraoperative mapping tool. Additionally, the cortical signals obtained by this modality can be utilized for localization in the presence of a tumor adjacent to the eloquent regions. PMID:19940544
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Eddy Current Examination With Visual Inspection... PACKAGINGS Pt. 180, App. C Appendix C to Part 180—Eddy Current Examination With Visual Inspection for DOT 3AL... procedure applicable to the test equipment it uses to perform eddy current examinations. 2. Visual...
Improvement in Magnetic Techniques for Rail Inspection
DOT National Transportation Integrated Search
1981-06-01
Current inspection of rail for internal defects is carried out by ultrasonic and/or magnetic technique for inspecting rail for internal flaws. The major emphasis was placed on improving the speed and detectability of current techniques. Experimental ...
NASA Astrophysics Data System (ADS)
Lu, Zheng; Huang, Biao; Zhang, Qi; Lu, Xilin
2018-05-01
Eddy-current tuned mass dampers (EC-TMDs) are non-contacting passive control devices and are developed on the basis of conventional tuned mass dampers. They comprise a solid mass, a stiffness element, and a damping element, wherein the damping mechanism originates from eddy currents. By relative motion between a non-magnetic conductive metal and a permanent magnet in a dynamic system, a time-varying magnetic field is induced in the conductor, thereby generating eddy currents. The eddy currents induce a magnetic field with opposite polarity, causing repulsive forces, i.e., damping forces. This technology can overcome the drawbacks of conventional tuned mass dampers, such as limited service life, deterioration of mechanical properties, and undesired additional stiffness. The experimental and analytical study of this system installed on a multi-degree-of-freedom structure is presented in this paper. A series of shaking table tests were conducted on a five-story steel-frame model with/without an EC-TMD to evaluate the effectiveness and performance of the EC-TMD in suppressing the vibration of the model under seismic excitations. The experimental results show that the EC-TMD can effectively reduce the displacement response, acceleration response, interstory drift ratio, and maximum strain of the columns under different earthquake excitations. Moreover, an analytical method was proposed on the basis of electromagnetic and structural dynamic theories. A comparison between the test and simulation results shows that the simulation method can be used to estimate the response of structures with an EC-TMD under earthquake excitations with acceptable accuracy.
Hönigsperger, Christoph; Nigro, Maximiliano J.
2016-01-01
Key points Kv2 channels underlie delayed‐rectifier potassium currents in various neurons, although their physiological roles often remain elusive. Almost nothing is known about Kv2 channel functions in medial entorhinal cortex (mEC) neurons, which are involved in representing space, memory formation, epilepsy and dementia.Stellate cells in layer II of the mEC project to the hippocampus and are considered to be space‐representing grid cells. We used the new Kv2 blocker Guangxitoxin‐1E (GTx) to study Kv2 functions in these neurons.Voltage clamp recordings from mEC stellate cells in rat brain slices showed that GTx inhibited delayed‐rectifier K+ current but not transient A‐type current.In current clamp, GTx had multiple effects: (i) increasing excitability and bursting at moderate spike rates but reducing firing at high rates; (ii) enhancing after‐depolarizations; (iii) reducing the fast and medium after‐hyperpolarizations; (iv) broadening action potentials; and (v) reducing spike clustering.GTx is a useful tool for studying Kv2 channels and their functions in neurons. Abstract The medial entorhinal cortex (mEC) is strongly involved in spatial navigation, memory, dementia and epilepsy. Although potassium channels shape neuronal activity, their roles in mEC are largely unknown. We used the new Kv2 blocker Guangxitoxin‐1E (GTx; 10–100 nm) in rat brain slices to investigate Kv2 channel functions in mEC layer II stellate cells (SCs). These neurons project to the hippocampus and are considered to be grid cells representing space. Voltage clamp recordings from SCs nucleated patches showed that GTx inhibited a delayed rectifier K+ current activating beyond –30 mV but not transient A‐type current. In current clamp, GTx (i) had almost no effect on the first action potential but markedly slowed repolarization of late spikes during repetitive firing; (ii) enhanced the after‐depolarization (ADP); (iii) reduced fast and medium after‐hyperpolarizations (AHPs); (iv) strongly enhanced burst firing and increased excitability at moderate spike rates but reduced spiking at high rates; and (v) reduced spike clustering and rebound potentials. The changes in bursting and excitability were related to the altered ADPs and AHPs. Kv2 channels strongly shape the activity of mEC SCs by affecting spike repolarization, after‐potentials, excitability and spike patterns. GTx is a useful tool and may serve to further clarify Kv2 channel functions in neurons. We conclude that Kv2 channels in mEC SCs are important determinants of intrinsic properties that allow these neurons to produce spatial representation. The results of the present study may also be important for the accurate modelling of grid cells. PMID:27562026
NASA Astrophysics Data System (ADS)
Isayama, A.; Suzuki, T.; Hayashi, N.; Ide, S.; Hamamatsu, K.; Fujita, T.; Hosoyama, H.; Kamada, Y.; Nagasaki, K.; Oyama, N.; Ozeki, T.; Sakata, S.; Seki, M.; Sueoka, M.; Takechi, M.; Urano, H.
2007-09-01
Recent results of control of current profile and instability using radiofrequency wave in JT-60U and prediction analysis in JT-60SA are descried. In JT-60U, control of current profile in high-beta regime was demonstrated by using a real-time system, where the motional Stark effect diagnostic and lower hybrid wave were used as a detector and actuator, respectively. The minimum value of the safety factor was raised from 1.3 to 1.7 so as to follow the commanded value. Complete stabilization of a neoclassical tearing mode (NTM) with the poloidal mode number m = 2 and the toroidal mode number n = 1 was demonstrated using electron cyclotron (EC) current drive. By scanning the location of EC current drive in detail, strong stabilization effect was found for misalignment less than about half of the full island width. In addition, destabilization of the 2/1 NTM was observed for misalignment comparable to the full island width. Simulation of NTM stabilization in JT-60SA was performed by using the TOPICS code combined with the modified Rutherford equation. The TOPICS simulation showed that complete stabilization can be achieved more effectively by optimizing the EC wave injection angle and modulating the EC wave.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isayama, A.; Suzuki, T.; Hayashi, N.
2007-09-28
Recent results of control of current profile and instability using radiofrequency wave in JT-60U and prediction analysis in JT-60SA are descried. In JT-60U, control of current profile in high-beta regime was demonstrated by using a real-time system, where the motional Stark effect diagnostic and lower hybrid wave were used as a detector and actuator, respectively. The minimum value of the safety factor was raised from 1.3 to 1.7 so as to follow the commanded value. Complete stabilization of a neoclassical tearing mode (NTM) with the poloidal mode number m = 2 and the toroidal mode number n = 1 wasmore » demonstrated using electron cyclotron (EC) current drive. By scanning the location of EC current drive in detail, strong stabilization effect was found for misalignment less than about half of the full island width. In addition, destabilization of the 2/1 NTM was observed for misalignment comparable to the full island width. Simulation of NTM stabilization in JT-60SA was performed by using the TOPICS code combined with the modified Rutherford equation. The TOPICS simulation showed that complete stabilization can be achieved more effectively by optimizing the EC wave injection angle and modulating the EC wave.« less
NASA Astrophysics Data System (ADS)
Wang, Wentao; Yu, Zhiming; Song, Xiuxian; Yuan, Yongquan; Wu, Zaixing; Zhou, Peng; Cao, Xihua
2018-03-01
During the autumn season of 2014 (October-November), nutrient samples and nitrogen and oxygen isotope samples from the East China Sea (ECS) were collected and analyzed, and auxiliary physical parameters were determined. Distinctive high-salinity water column conditions with significant haloclines and pycnoclines similar to those observed during the spring were detected at the bottom of the ECS during the autumn. These water column conditions were attributed to the intrusion of the Kuroshio Subsurface Water (KSSW), which then separated into two currents, including the Offshore Kuroshio Branch Current (OKBC). Compared with spring, this intrusion transported higher phosphorus (P) concentrations onto the ECS continental shelf in autumn. However, according to multiple analyses, biogeochemical nitrogen processes are unable to explain the variations in the P concentrations (increase) while assuming that each distinctive water column is consistent. Identifying the water columns by their salinities and P concentrations revealed that the northern ECS water column was similar to the deep KSSW while the southern ECS water column was similar to the shallow KSSW. Therefore, we speculate that the distinctions among the seasonal variations of P-enriched water masses were attributable to the different intrusion positions of the Kuroshio. The shift of the KSSW intrusion location moved toward the northeast during the autumn relative to the spring. This shift, which was proved by the oceanic vortex data, caused the deeper KSSW water upwelled to the ECS and formed the OKBC, thereby supplying additional P during the autumn.
AGU Student and Early Career Leadership
NASA Astrophysics Data System (ADS)
Dolan, A. M.; Tamalavage, A.; Crumsey, J.; Klima, K.; Lechner, H. N.; LLera, K.; Oaida, C.; Okoro, M. H.; Riker, J.; van Emmerik, T. H. M.; Enderlein, C.
2017-12-01
The American Geophysical Union (AGU) is the largest single organization dedicated to the advancement of geophysics in order to promote discovery in Earth and space science for the benefit of humanity. AGU unites scientists across disciplines by promoting collaborative advances in Earth, atmospheric, oceanic, hydrologic, space, and planetary sciences. One critical strand of AGU is the volunteer leaders who work together with AGU staff to ensure that the voice of the AGU membership is heard in all forms of decision making within the organization. Volunteer leaders include the president and president elect of individual Section and Focus groups, and importantly Student and Early Career (S/EC) representatives from across the AGU landscape. Here, we will describe the roles of past and current AGU S/EC leaders and how these roles have evolved from the onset of student and early career scientist representation on the AGU Council. We will also discuss current plans for solidifying the relationship between S/EC leaders and other S/EC volunteers within AGU (e.g. those who sit on the executive committees of Section or Focus groups). We will describe the process for becoming an AGU S/EC leader and the roles that current S/EC leaders fulfill on the AGU Council, the Board, the Council Leadership Team, and on various committees that enable decision making and progress within AGU (e.g. the Governance Committee, the Centennial Committee, and the Ethics Committee). Including S/EC volunteers within AGU leadership ensures that the organization indeed progresses forward to achieve the vision of AGU: to galvanize a community of Earth and space scientists that collaboratively advances and communicates science and its power to ensure a sustainable future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farina, D.; Figini, L.; Henderson, M.
2014-06-15
The design of the ITER Electron Cyclotron Heating and Current Drive (EC H and CD) system has evolved in the last years both in goals and functionalities by considering an expanded range of applications. A large effort has been devoted to a better integration of the equatorial and the upper launchers, both from the point of view of the performance and of the design impact on the engineering constraints. However, from the analysis of the ECCD performance in two references H-mode scenarios at burn (the inductive H-mode and the advanced non-inductive scenario), it was clear that the EC power depositionmore » was not optimal for steady-state applications in the plasma region around mid radius. An optimization study of the equatorial launcher is presented here aiming at removing this limitation of the EC system capabilities. Changing the steering of the equatorial launcher from toroidal to poloidal ensures EC power deposition out to the normalized toroidal radius ρ ≈ 0.6, and nearly doubles the EC driven current around mid radius, without significant performance degradation in the core plasma region. In addition to the improved performance, the proposed design change is able to relax some engineering design constraints on both launchers.« less
NASA Astrophysics Data System (ADS)
Darbos, C.; Henderson, M.; Albajar, F.; Bigelow, T.; Bomcelli, T.; Chavan, R.; Denisov, G.; Farina, D.; Gandini, F.; Heidinger, R.; Goodman, T.; Hogge, J. P.; Kajiwara, K.; Kasugai, A.; Kern, S.; Kobayashi, N.; Oda, Y.; Ramponi, G.; Rao, S. L.; Rasmussen, D.; Rzesnicki, T.; Saibene, G.; Sakamoto, K.; Sauter, O.; Scherer, T.; Strauss, D.; Takahashi, K.; Zohm, H.
2009-11-01
A 26 MW Electron Cyclotron Heating and Current Drive (EC H&CD) system is to be installed for ITER. The main objectives are to provide, start-up assist, central H&CD and control of MHD activity. These are achieved by a combination of two types of launchers, one located in an equatorial port and the second type in four upper ports. The physics applications are partitioned between the two launchers, based on the deposition location and driven current profiles. The equatorial launcher (EL) will access from the plasma axis to mid radius with a relatively broad profile useful for central heating and current drive applications, while the upper launchers (ULs) will access roughly the outer half of the plasma radius with a very narrow peaked profile for the control of the Neoclassical Tearing Modes (NTM) and sawtooth oscillations. The EC power can be switched between launchers on a time scale as needed by the immediate physics requirements. A revision of all injection angles of all launchers is under consideration for increased EC physics capabilities while relaxing the engineering constraints of both the EL and ULs. A series of design reviews are being planned with the five parties (EU, IN, JA, RF, US) procuring the EC system, the EC community and ITER Organization (IO). The review meetings qualify the design and provide an environment for enhancing performances while reducing costs, simplifying interfaces, predicting technology upgrades and commercial availability. In parallel, the test programs for critical components are being supported by IO and performed by the Domestic Agencies (DAs) for minimizing risks. The wide participation of the DAs provides a broad representation from the EC community, with the aim of collecting all expertise in guiding the EC system optimization. Still a strong relationship between IO and the DA is essential for optimizing the design of the EC system and for the installation and commissioning of all ex-vessel components when several teams from several DAs will be involved together in the tests on the ITER site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobranich, P.R.; Widney, T.W.; Goolsby, P.T.
The on-site inspection provisions in many current and proposed arms control agreements require extensive preparation and training on the part of both the Inspected Party and the Inspection Team. Current training techniques include table-top inspections and practice inspections. The Augmented Computer Exercise for Inspection Training (ACE-IT), an interactive computer training tool, increases the utility of table-top inspections. ACE-IT has been designed to provide training for a hypothetical challenge inspection under the Chemical Weapons Convention (CWC); however, this training tool can be modified for other inspection regimes. Although ACE-IT provides training from notification of an inspection through post-inspection activities, the primarymore » emphasis of ACE-IT is in the inspection itself--particularly with the concept of managed access. ACE-IT also demonstrates how inspection provisions impact compliance determination and the protection of sensitive information. The Exercise Manual supplements the ACE-IT software by providing general information on on-site inspections and detailed information for the CWC challenge inspection exercise. The detailed information includes the pre-inspection briefing, maps, list of sensitive items, medical records, and shipping records.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-24
... if necessary. This proposed AD would also add an option for the high frequency eddy current... also adds an optional ultrasonic inspection for the high frequency eddy current inspection to detect... proposed AD would also add an option for the high frequency eddy current inspection for cracking of the...
77 FR 21395 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... would require performing a low frequency eddy current inspection for cracks of the lap joint of the rear...-frequency eddy current inspection of the lap joint for cracks and, depending on findings, repair of the lap... AD: Do a low frequency eddy current (LFEC) inspection for cracks of the lap joint of the rear...
Electric and hybrid vehicle environmental control subsystem study
NASA Technical Reports Server (NTRS)
Heitner, K. L.
1980-01-01
An environmental control subsystem (ECS) in electric and hybrid vehicles is studied. A combination of a combustion heater and gasoline engine (Otto cycle) driven vapor compression air conditioner is selected. The combustion heater, the small gasoline engine, and the vapor compression air conditioner are commercially available. These technologies have good cost and performance characteristics. The cost for this ECS is relatively close to the cost of current ECS's. Its effect on the vehicle's propulsion battery is minimal and the ECS size and weight do not have significant impact on the vehicle's range.
ERIC Educational Resources Information Center
Hoff, David J.
2006-01-01
Kathy Christie, senior vice president at the Education Commission of the States (ECS), resigned on May 1, 2006, saying that the Denver-based group faces a financial crisis, and that she doubts the current ECS president can fix it. By the end of the week, the accounting manager had also resigned, expressing similar concerns, and two policy analysts…
NASA Astrophysics Data System (ADS)
Tachibana, Rie; Kohlhase, Naja; Näppi, Janne J.; Hironaka, Toru; Ota, Junko; Ishida, Takayuki; Regge, Daniele; Yoshida, Hiroyuki
2016-03-01
Accurate electronic cleansing (EC) for CT colonography (CTC) enables the visualization of the entire colonic surface without residual materials. In this study, we evaluated the accuracy of a novel multi-material electronic cleansing (MUMA-EC) scheme for non-cathartic ultra-low-dose dual-energy CTC (DE-CTC). The MUMA-EC performs a wateriodine material decomposition of the DE-CTC images and calculates virtual monochromatic images at multiple energies, after which a random forest classifier is used to label the images into the regions of lumen air, soft tissue, fecal tagging, and two types of partial-volume boundaries based on image-based features. After the labeling, materials other than soft tissue are subtracted from the CTC images. For pilot evaluation, 384 volumes of interest (VOIs), which represented sources of subtraction artifacts observed in current EC schemes, were sampled from 32 ultra-low-dose DE-CTC scans. The voxels in the VOIs were labeled manually to serve as a reference standard. The metric for EC accuracy was the mean overlap ratio between the labels of the reference standard and the labels generated by the MUMA-EC, a dualenergy EC (DE-EC), and a single-energy EC (SE-EC) scheme. Statistically significant differences were observed between the performance of the MUMA/DE-EC and the SE-EC methods (p<0.001). Visual assessment confirmed that the MUMA-EC generated less subtraction artifacts than did DE-EC and SE-EC. Our MUMA-EC scheme yielded superior performance over conventional SE-EC scheme in identifying and minimizing subtraction artifacts on noncathartic ultra-low-dose DE-CTC images.
Meta-audit of laboratory ISO accreditation inspections: measuring the old emperor's clothes.
Wilson, Ian G; Smye, Michael; Wallace, Ian J C
2016-02-01
Accreditation to ISO/IEC 17025 is required for EC official food control and veterinary laboratories by Regulation (EC) No. 882/2004. Measurements in hospital laboratories and clinics are increasingly accredited to ISO/IEC 15189. Both of these management standards arose from command and control military standards for factory inspection during World War II. They rely on auditing of compliance and have not been validated internally as assessment bodies require of those they accredit. Neither have they been validated to criteria outside their own ideology such as the Cochrane principles of evidence-based medicine which might establish whether any benefit exceeds their cost. We undertook a retrospective meta-audit over 14 years of internal and external laboratory audits that checked compliance with ISO 17025 in a public health laboratory. Most noncompliances arose solely from clauses in the standard and would not affect users. No effect was likely from 91% of these. Fewer than 1% of noncompliances were likely to have consequences for the validity of results or quality of service. The ISO system of compliance auditing has the performance characteristics of a poor screening test. It adds substantially to costs and generates more noise (false positives) than informative signal. Ethical use of resources indicates that management standards should not be used unless proven to deliver the efficacy, effectiveness, and value required of modern healthcare interventions. © 2015 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.
Early diagnostic potential of APC hypermethylation in esophageal cancer.
Wang, Bujiang; Song, Haojun; Jiang, Haizhong; Fu, Yangbo; Ding, Xiaoyun; Zhou, Chongchang
2018-01-01
The hypermethylation of APC gene is observed in various cancers, including esophageal cancer (EC). However, the association between APC methylation and the initiation and progression of EC is poorly understood. The current study systematically reviewed studies on abnormal methylation of APC in EC and quantitatively synthesized 18 studies by meta-analysis involving 1008 ECs, 570 Barrett's esophagus (BE), and 782 controls. Our results showed higher methylation of APC in EC (OR = 23.33, P < 0.001) and BE (OR = 9.34, P < 0.001) than in normal controls. Whereas APC methylation in EC was similar to that in BE ( P = 0.052), it was not associated with tumor stage ( P = 0.204). Additionally, APC methylation was not significantly associated with overall survival (OS) and relapse-free survival (RFS) in patients with EC. The performance of APC methylation for the detection of EC and BE achieved areas under the receiver operating characteristic curves of 0.94 and 0.88, respectively. Our results imply that APC methylation detection is a potential diagnostic biomarker for EC and BE.
Shell Inspection History and Current CMM Inspection Efforts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montano, Joshua Daniel
The following report provides a review of past and current CMM Shell Inspection efforts. Calibration of the Sheffield rotary contour gauge has expired and the primary inspector, Matthew Naranjo, has retired. Efforts within the Inspection team are transitioning from maintaining and training new inspectors on Sheffield to off-the-shelf CMM technology. Although inspection of a shell has many requirements, the scope of the data presented in this report focuses on the inner contour, outer contour, radial wall thickness and mass comparisons.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... (BSI) or eddy current inspection (ECI) of the disk outer rim front rail for cracks prior to... date of this AD. (ii) Perform a borescope inspection (BSI) or eddy current inspection (ECI) of the...
76 FR 9495 - Airworthiness Directives; Air Tractor, Inc. Models AT-802 and AT-802A Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
...-18, which requires you to repetitively inspect (using the eddy current method) the two outboard... through 0101 and AT-802A-0092 through 0101: To perform, using the eddy current method, two inspections at... through 0178 and AT-802A-0102 through 0178 to perform using the eddy current method, two inspections at 5...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... this AD, perform an external eddy current inspection of the forward fuselage skin to detect cracking... paragraphs (j)(1), (j)(2), and (j)(3) of this AD, do an external eddy current inspection of the forward... this AD, do an external eddy current inspection of the forward fuselage skin to detect cracking, in...
Verdonck, Michèle; Steggles, Elizabeth; Nolan, Maeve; Chard, Gill
2014-01-01
Environmental Control Systems (ECS) have many benefits; however studies of personal experience of ECS use are scarce. This qualitative study explored the insiders' experience of using an ECS. An ECS starter-pack was compiled and trialled for an eight-week period with six persons with high spinal cord injuries (SCI) living in Ireland. Semi-structured interviews were subsequently completed with each person and analysed using Interpretative Phenomenological Analysis (IPA). Two major themes emerged: "Taking back a little of what has been lost", and "Getting used to ECS" which is the focus of the current paper. This theme captured a dynamic interplay between the experience of "hassle" and "engagement" for new users of ECS. "Hassle" resulted from technological frustrations and the challenge of breaking familiar habits, while "Engagement" resulted from feeling good, having fun and being surprised. The complex interweaving of hassle and engagement experienced by new ECS users reflects the clinical experience of rehabilitation providers. The importance of overcoming initial hassle needs to be understood by clinicians and users in order to maximise the potential benefit of ECS. Non-use must be considered one reasonable outcome if based on realistic ECS trials.
Korpinen, Leena H; Elovaara, Jarmo A; Kuisti, Harri A
2011-01-01
The aim of the study was to investigate the occupational exposure to electric fields, average current densities, and average total contact currents at 400 kV substation tasks from different service platforms (main transformer inspection, maintenance of operating device of disconnector, maintenance of operating device of circuit breaker). The average values are calculated over measured periods (about 2.5 min). In many work tasks, the maximum electric field strengths exceeded the action values proposed in the EU Directive 2004/40/EC, but the average electric fields (0.2-24.5 kV/m) were at least 40% lower than the maximum values. The average current densities were 0.1-2.3 mA/m² and the average total contact currents 2.0-143.2 µA, that is, clearly less than the limit values of the EU Directive. The average values of the currents in head and contact currents were 16-68% lower than the maximum values when we compared the average value from all cases in the same substation. In the future it is important to pay attention to the fact that the action and limit values of the EU Directive differ significantly. It is also important to take into account that generally, the workers' exposure to the electric fields, current densities, and total contact currents are obviously lower if we use the average values from a certain measured time period (e.g., 2.5 min) than in the case where exposure is defined with only the help of the maximum values. © 2010 Wiley-Liss, Inc.
Effect of early childhood malnutrition on tooth eruption in Haitian adolescents.
Psoter, W; Gebrian, B; Prophete, S; Reid, B; Katz, R
2008-04-01
The objective of this retrospective cohort study was to determine the effects of early childhood protein-energy malnutrition (EC-PEM) and current nutritional status as defined by anthropomorphic measures on the exfoliation and eruption patterns of teeth among adolescents. Oral clinical examinations were conducted in 2005 using World Health Organization (WHO) diagnostic criteria on 498 11- to 13-year-old Haitians for whom early childhood malnutrition data were available. Anthropomorphic records (weight-for-age) from the Haitian Health Foundation computerized database on children from birth through 5-years old were utilized. Current heights and weights were ascertained. Both sets of data were converted to z-scores based on the National Center for Health Statistics (NCHS) referent database. Based upon these z-scores, EC-PEM and current malnutrition categories were developed for this study. The analyses separately regressed the number of primary and permanent teeth on age, gender, EC-PEM status and current nutritional status. Both a delayed exfoliation of primary teeth and a delayed eruption of permanent teeth were associated with EC-PEM and current stunting in adolescence. The observed associations were either direct and statistically significant or indirectly demonstrated by presenting evidence of confounding. The overall interpretation of the models is that malnutrition beginning in the earliest years and extending throughout childhood influences the exfoliation and eruption of teeth. These findings present evidence of an association between tooth exfoliation/eruption patterns and both EC-PEM and nutritional insufficiency (stunting) throughout childhood. This observed delay in the exfoliation of the primary dentition and in the eruption of the permanent dentition has practical significance in interpreting age-specific dental caries data from populations with different malnutrition experiences.
NASA Astrophysics Data System (ADS)
Mandache, C.; Khan, M.; Fahr, A.; Yanishevsky, M.
2011-03-01
Probability of detection (PoD) studies are broadly used to determine the reliability of specific nondestructive inspection procedures, as well as to provide data for damage tolerance life estimations and calculation of inspection intervals for critical components. They require inspections on a large set of samples, a fact that makes these statistical assessments time- and cost-consuming. Physics-based numerical simulations of nondestructive testing inspections could be used as a cost-effective alternative to empirical investigations. They realistically predict the inspection outputs as functions of the input characteristics related to the test piece, transducer and instrument settings, which are subsequently used to partially substitute and/or complement inspection data in PoD analysis. This work focuses on the numerical modelling aspects of eddy current testing for the bolt hole inspections of wing box structures typical of the Lockheed Martin C-130 Hercules and P-3 Orion aircraft, found in the air force inventory of many countries. Boundary element-based numerical modelling software was employed to predict the eddy current signal responses when varying inspection parameters related to probe characteristics, crack geometry and test piece properties. Two demonstrator exercises were used for eddy current signal prediction when lowering the driver probe frequency and changing the material's electrical conductivity, followed by subsequent discussions and examination of the implications on using simulated data in the PoD analysis. Despite some simplifying assumptions, the modelled eddy current signals were found to provide similar results to the actual inspections. It is concluded that physics-based numerical simulations have the potential to partially substitute or complement inspection data required for PoD studies, reducing the cost, time, effort and resources necessary for a full empirical PoD assessment.
Paulista, Larissa Oliveira; Presumido, Pedro Henrique; Theodoro, Joseane Debora Peruço; Pinheiro, Alexei Lorenzetti Novaes
2018-05-08
The application of electrocoagulation (EC) and electroflotation (EF) was investigated for the treatment of poultry slaughterhouse wastewater in a bench scale unit cell electrolyzer with different EC-to-EF ratios at current densities of 3, 9, and 15 mA cm -2 . The EC-to-EF ratio was controlled by current reversal using aluminum and graphite electrodes. The electrochemical treatment showed satisfactory removal efficiencies for Al coagulant loads greater than 51.8 mg L -1 . The 4/5 EC to EF ratio (69.1 mg L -1 Al and 32.2 NmL L -1 additional EF gas) and 3/5 (51.8 mg L -1 Al/64 NmL L -1 additional EF gas) presented the best results for the removal of COD (76-85%), color (93-99%), and turbidity (95-99%), with the additional benefit of reducing the electrode consumption and sludge disposal costs proportionally to the EC-to-EF ratio. The effects of the EC-to-EF ratio and the current density on efficiency of the electrochemical treatment for the removal of COD, apparent color, turbidity, TSS, TSD, and NH 3 -N were discussed in the light of the physicochemical and electrochemical processes underlying the removal mechanism for each parameter. In particular, the blow-off mechanism seems to play an important role in the NH 3 -N removal, whereas indirect electrooxidation mechanism accounts for a fraction of the soluble COD removal for the electrodes configuration used in the treatment.
A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.
Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming
2017-07-01
To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-23
... one-time high frequency eddy current inspection of fastener holes for cracks at the left and right... frequency eddy current inspection of fastener holes for cracks at the left and right side wing rear spar... frequency eddy current inspection for cracking of fastener holes at the left and right side wing rear spar...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-19
... proposed AD would require a one-time high frequency eddy current inspection of fastener holes for cracks at... high frequency eddy current inspection of fastener holes for cracking at the left and right side wing... of this AD, do a one-time high frequency eddy current inspection for cracking of fastener holes at...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... eddy current inspection for cracking of the keyway of the fuel tank access door cutout on the left and... frequency eddy current (HFEC) inspection for cracking at the keyway of the fuel tank access door cutout on... frequency eddy current (HFEC) inspection for cracking of the keyway of the fuel tank access door cutout on...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-12
... eddy current and visual inspections of the upper wing strut fitting for evidence of cracks, wear and/or... permitted extending the intervals for the repetitive eddy current and visual inspections from 100 Flight... the applicability and to require repetitive eddy current and visual inspections of the upper wing...
77 FR 63264 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... manufacturer cannot be identified, do a high frequency eddy current (HFEC) inspection for cracking of the... a high frequency eddy current (HFEC) method and, depending on findings, accomplishment of the... inspection of the rods to determine the manufacturer; and for affected parts, an inspection for any cracking...
Eating competence of college students in an introductory nutrition course.
Brown, Lora Beth; Larsen, Katrina J; Nyland, Nora K; Eggett, Dennis L
2013-01-01
Describe eating competence, a positive and flexible way of conceptualizing eating attitudes and behaviors, in students enrolled in an introductory nutrition course. Online completion of the Satter Eating Competence Inventory (ecSI) and self-assessment of eating disorder status by 557 students (343 ages 18-20 years and 180 ages 21-26 years; 377 females) at the beginning of 1 semester. Analysis of variance and post hoc Tukey adjusted tests were used. The mean ecSI score was 30.7 ± 0.29; 47.4% were classified as eating competent, or ecSI ≥ 32. Mean ecSI was higher for males than females (29.4 ± 0.95 vs 27.4 ± 0.77; P < .001). Mean ecSI was higher for students who never had an eating disorder, compared with those reporting current (32.0 ± 0.43 vs 22.9 ± 1.91; P < .001) or past (28.8 ± 0.93; P < .01) eating disorders. Students had limited eating competence, but a majority of males were eating competent. Students who had never had an eating disorder had higher eating competence than students with current or past disorders. Examining nutrition courses as currently taught may reveal ways courses could contribute to eating competence. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Data Sharing and Scientific Impact in Eddy Covariance Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bond-Lamberty, B.
Do the benefits of data sharing outweigh its perceived costs? This is a critical question, and one with the potential to change culture and behavior. Dai et al. (2018) examine how data sharing is related to scientific impact in the field of eddy covariance (EC), and find that data sharers are disproportionately high-impact researchers, and vice versa; they also note strong regional differences in EC data sharing norms. The current policies and restrictions of EC journals and repositories are highly uneven. Incentivizing data sharing and enhancing computational reproducibility are critical next steps for EC, ecology, and science more broadly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Lijen; Bessho, Naoki; Bhattacharjee, Amitava
Open questions concerning structures and dynamics of diffusion regions and electron acceleration in collisionless magnetic reconnection are addressed based on data from the four-spacecraft mission Cluster and particle-in-cell simulations. Using time series of electron distribution functions measured by the four spacecraft, distinct electron regions around a reconnection layer are mapped out to set the framework for studying diffusion regions. A spatially extended electron current sheet (ecs), a series of magnetic islands, and bursts of energetic electrons within islands are identified during magnetotail reconnection with no appreciable guide field. The ecs is collocated with a layer of electron-scale electric fields normalmore » to the ecs and pointing toward the ecs center plane. Both the observed electron and ion densities vary by more than a factor of 2 within one ion skin depth north and south of the ecs, and from the ecs into magnetic islands. Within each of the identified islands, there is a burst of suprathermal electrons whose fluxes peak at density compression sites [L.-J. Chen et al., Nat. Phys. 4, 19 (2008)] and whose energy spectra exhibit power laws with indices ranging from 6 to 7.3. These results indicate that the in-plane electric field normal to the ecs can be of the electron scale at certain phases of reconnection, electrons and ions are highly compressible within the ion diffusion region, and for reconnection involving magnetic islands, primary electron acceleration occurs within the islands.« less
NASA Astrophysics Data System (ADS)
Benettin, P.; Van Breukelen, B. M.
2017-12-01
The ability to evaluate stream hydrochemistry is often constrained by the capacity to sample streamwater at an adequate frequency. While technology is no longer a limiting factor, economic and management efforts can still be a barrier to high-resolution water quality instrumentation. We propose a new framework to investigate the electrical conductivity (EC) of streamwater, which can be measured continuously through inexpensive sensors. We show that EC embeds information on ion content which can be isolated to retrieve solute concentrations at high resolution. The approach can already be applied to a number of datasets worldwide where water quality campaigns are conducted, provided continuous EC measurements can be collected. The essence of the approach is the decomposition of the EC signal into its "harmonics", i.e. the specific contributions of the major ions which conduct current in water. The ion contribution is used to explore water quality patterns and to develop algorithms that reconstruct solute concentrations during periods where solute measurements are not available. The approach is validated on a hydrochemical dataset from Plynlimon, Wales. Results show that the decomposition of EC is feasible and for at least two major elements the methodology provided improved estimates of high-frequency solute dynamics. Our results support the installation of EC probes to complement water quality campaigns and suggest that the potential of EC measurements in rivers is currently far from being fully exploited.
Using SCR methods to analyze requirements documentation
NASA Technical Reports Server (NTRS)
Callahan, John; Morrison, Jeffery
1995-01-01
Software Cost Reduction (SCR) methods are being utilized to analyze and verify selected parts of NASA's EOS-DIS Core System (ECS) requirements documentation. SCR is being used as a spot-inspection tool. Through this formal and systematic approach of the SCR requirements methods, insights as to whether the requirements are internally inconsistent or incomplete as the scenarios of intended usage evolve in the OC (Operations Concept) documentation. Thus, by modelling the scenarios and requirements as mode charts using the SCR methods, we have been able to identify problems within and between the documents.
Current food chain information provides insufficient information for modern meat inspection of pigs.
Felin, Elina; Jukola, Elias; Raulo, Saara; Heinonen, Jaakko; Fredriksson-Ahomaa, Maria
2016-05-01
Meat inspection now incorporates a more risk-based approach for protecting human health against meat-borne biological hazards. Official post-mortem meat inspection of pigs has shifted to visual meat inspection. The official veterinarian decides on additional post-mortem inspection procedures, such as incisions and palpations. The decision is based on declarations in the food chain information (FCI), ante-mortem inspection and post-mortem inspection. However, a smooth slaughter and inspection process is essential. Therefore, one should be able to assess prior to slaughter which pigs are suitable for visual meat inspection only, and which need more profound inspection procedures. This study evaluates the usability of the FCI provided by pig producers and considered the possibility for risk ranking of incoming slaughter batches according to the previous meat inspection data and the current FCI. Eighty-five slaughter batches comprising 8954 fattening pigs were randomly selected at a slaughterhouse that receives animals from across Finland. The mortality rate, the FCI and the meat inspection results for each batch were obtained. The current FCI alone provided insufficient and inaccurate information for risk ranking purposes for meat inspection. The partial condemnation rate for a batch was best predicted by the partial condemnation rate calculated for all the pigs sent for slaughter from the same holding in the previous year (p<0.001) and by prior information on cough declared in the current FCI (p=0.02) statement. Training and information to producers are needed to make the FCI reporting procedures more accurate. Historical meat inspection data on pigs slaughtered from the same holdings and well-chosen symptoms/signs for reporting, should be included in the FCI to facilitate the allocation of pigs for visual inspection. The introduced simple scoring system can be easily used for additional information for directing batches to appropriate meat inspection procedures. To control the main biological public health hazards related to pork, serological surveillance should be done and the information obtained from analyses should be used as part of the FCI. Copyright © 2016 Elsevier B.V. All rights reserved.
Emerging Contaminants Identification, Concerns, Actions
This presentation serves as a background introduction to a current EPA/ORD study on the characterization and treatment of emerging contaminants (ECs ) in wet-weather flows. It briefly discusses other ongoing work relating to ECs and provides the foundation for prioritizing the c...
78 FR 21079 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... accomplished. The initial inspection may be either a detailed inspection or a bolt- hole eddy current (BHEC... inspection or a bolt-hole eddy current (BHEC) test for cracking of each nacelle lower longeron, in accordance...-39, Revision A, dated August 2, 2012, specify to contact the manufacturer for instructions to repair...
Inspection of cup-shaped steel parts from the I.D. side using eddy current
NASA Astrophysics Data System (ADS)
Griffiths, Erick W.; Pearson, Lee H.
2018-04-01
An eddy current method was developed to inspect cup-shaped steel parts from the I.D. side. During the manufacturing process of these parts, a thin Al tape foil is applied to the I.D. side of the part. One of the critical process parameters is that only one foil layer can be applied. An eddy current inspection system was developed to reject parts with more than one foil layer. The Al tape foil is cut to length to fit the inner diameter, however, after application of the foil there is a gap created between the beginning and end of the foil. It was found that this gap interfered with the eddy current inspection causing a false positive indication. To solve this problem a sensor design and data analysis process were developed to overcome the effects of these gaps. The developed system incorporates simultaneous measurements from multiple eddy current sensors and signal processing to achieve a reliable inspection.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... effective date of this AD: Perform an in situ eddy current inspection for cracks on the forward lug of the...-6B11 (CL-415 Variant) airplanes). Thereafter, repeat the in situ eddy current inspection at intervals not to exceed 165 land landings. (2) If no crack is found: Repeat the in situ eddy current inspection...
Electroconvection in one-dimensional liquid crystal cells
NASA Astrophysics Data System (ADS)
Huh, Jong-Hoon
2018-04-01
We investigate the alternating current (ac) -driven electroconvection (EC) in one-dimensional cells (1DCs) under the in-plane switching mode. In 1DCs, defect-free EC can be realized. In the presence and absence of external multiplicative noise, the features of traveling waves (TWs), such as their Hopf frequency fH and velocity, are examined in comparison with those of conventional two-dimensional cells (2DCs) accompanying defects of EC rolls. In particular, we show that the defects significantly contribute to the features of the TWs. Additionally, owing to the defect-free EC in the 1DCs, the effects of the ac and noise fields on the TW are clarified. The ac field linearly increases fH, independent of the ac frequency f . The noise increases fH monotonically, but fH does not vary below a characteristic noise intensity VN*. In addition, soliton-like waves and unfamiliar oscillation of EC vortices in 1DCs are observed, in contrast to the localized EC (called worms) and the oscillation of EC rolls in 2DCs.
Research Trends in Emerging Contaminants on the Aquatic Environments of Tanzania
Miraji, H.; Othman, O. C.; Ngassapa, F. N.; Mureithi, E. W.
2016-01-01
The continuity for discovery and production of new chemicals, allied products, and uses has currently resulted into generation of recent form of contaminants known as Emerging Contaminants (ECs). Once in the aquatic environment ECs are carcinogenic and cause other threats to both human's and animals' health. Due to their effects this study was aimed at investigating research trends of ECs in Tanzania. Findings revealed that USA and EU countries were leading in ECs researches, little followed by Asia, South Africa, and then Zambia. Only few guidelines from USA-EPA, WHO, Canada, and Australia existed. Neither published guidelines nor regulations for ECs existed in Tanzania; rather only the occurrence of some disinfection by-products and antibiotics was, respectively, reported in Arusha and Dar es Salaam, Tanzania. As these reports had a limited coverage of ECs, henceforth, these findings constitute the first-line reference materials for ECs research in Tanzania which shall be useful for future monitoring and regulation planning. PMID:26998381
Emerging contaminants in surface waters in China—a short review
NASA Astrophysics Data System (ADS)
Yang, Guang; Fan, Maohong; Zhang, Guangming
2014-07-01
Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L-1 to μg L-1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched.
Joddar, Binata; Kumar, Shweta Anil; Kumar, Alok
2018-06-01
Adult stem cells such as mesenchymal stem cells (MSC) are known to possess the ability to augment neovascularization processes and are thus widely popular as an autologous source of progenitor cells. However there is a huge gap in our current knowledge of mechanisms involved in differentiating MSC into endothelial cells (EC), essential for lining engineered blood vessels. To fill up this gap, we attempted to differentiate human MSC into EC, by culturing the former onto chemically fixed layers of EC or its ECM, respectively. We expected direct contact of MSC when cultured atop fixed EC or its ECM, would coax the former to differentiate into EC. Results showed that human MSC cultured atop chemically fixed EC or its ECM using EC-medium showed enhanced expression of CD31, a marker for EC, compared to other cases. Further in all human MSC cultured using EC-medium, typically characteristic cobble stone shaped morphologies were noted in comparison to cells cultured using MSC medium, implying that the differentiated cells were sensitive to soluble VEGF supplementation present in the EC-medium. Results will enhance and affect therapies utilizing autologous MSC as a cell source for generating vascular cells to be used in a variety of tissue engineering applications.
46 CFR 2.10-101 - Annual vessel inspection fee.
Code of Federal Regulations, 2010 CFR
2010-10-01
... inspections, damage surveys, repair and modification inspections, change in vessel service inspections, permit... of international certificates. (d) Entitlement to inspection services for the current year remains... MODUs 4,695 Semi-submersible MODUs 8,050 Nautical School Vessels: Length not greater than 100 feet 835...
Electrocoagulation in Water Treatment
NASA Astrophysics Data System (ADS)
Liu, Huijuan; Zhao, Xu; Qu, Jiuhui
Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.
GilPavas, Edison; Arbeláez-Castaño, Paula; Medina, José; Acosta, Diego A
2017-11-01
A combined electrocoagulation (EC) and electrochemical oxidation (EO) industrial textile wastewater treatment potential is evaluated in this work. A fractional factorial design of experiment showed that EC current density, followed by pH, were the most significant factors. Conductivity and number of electrooxidation cells did not affect chemical oxygen demand degradation (DCOD). Aluminum and iron anodes performed similarly as sacrificial anodes. Current density, pH and conductivity were chosen for a Box-Behnken design of experiment to determine optimal conditions to achieve a high DCOD minimizing operating cost (OC). The optimum to achieve a 70% DCOD with an OC of USD 1.47/m 3 was: pH of 4, a conductivity of 3.7 mS/cm and a current density of 4.1 mA/cm 2 . This study also shows the applicability of a combined EC/EO treatment process of a real complex industrial wastewater.
NASA Astrophysics Data System (ADS)
van Genuchten, C. M.; Pena, J.; Addy, S.; Gadgil, A.
2010-12-01
Millions of people worldwide are exposed to arsenic-contamination in groundwater drinking supplies. The majority of affected people live in rural Bangladesh. Electrocoagulation (EC) using iron electrodes is a promising arsenic removal strategy that is based on the generation of iron precipitates with a high affinity for arsenic through the electrochemical dissolution of a sacrificial iron anode. Many studies of iron hydrolysis in the presence of co-occurring ions in groundwater such as PO43-, SiO44-, and AsO43- suggest that these ions influence the polymerization and formation of iron oxide phases. However, the combined impact of these ions on precipitates generated by EC is not well understood. X-ray absorption spectroscopy (XAS) was used to examine EC precipitates generated in synthetic Bangladeshi groundwater (SBGW). The iron oxide structure and arsenic binding geometry were investigated as a function of EC operating conditions. As and Fe k-edge spectra were similar between samples regardless of the large range of current density (0.02, 1.1, 5.0, 100 mA/cm2) used during sample generation. This result suggests that current density does not play a large role in the formation EC precipitates in SBGW. Shell-by-shell fits of Fe K-edge data revealed the presence of a single Fe-Fe interatomic distance at approximately 3.06 Å. The absence of longer ranged Fe-Fe correlations suggests that EC precipitates consist of nano-scale chains (polymers) of FeO6 octahedra sharing equatorial edges. Shell-by-shell fits of As K-edge spectra show arsenic bound in primarily bidentate, binuclear corner sharing complexes. In this coordination geometry, arsenic prevents the formation of FeO6 corner-sharing linkages, which are necessary for 3-dimensional crystal growth. The individual and combined effects of other anions, such as PO43- and SiO44- present in SBGW are currently being investigated to determine the role of these ions in stunting crystal growth. The results provided by this study are useful in explaining the large adsorption capacity of EC precipitates. This study will also lead to better predictions of arsenic removal efficiency during EC and a better understanding of the long-term stability of arsenic-laden EC sludge.
NASA Astrophysics Data System (ADS)
Santospirito, S. P.; Słyk, Kamil; Luo, Bin; Łopatka, Rafał; Gilmour, Oliver; Rudlin, John
2013-05-01
Detection of defects in Laser Powder Deposition (LPD) produced components has been achieved by laser thermography. An automatic in-process NDT defect detection software system has been developed for the analysis of laser thermography to automatically detect, reliably measure and then sentence defects in individual beads of LPD components. A deposition path profile definition has been introduced so all laser powder deposition beads can be modeled, and the inspection system has been developed to automatically generate an optimized inspection plan in which sampling images follow the deposition track, and automatically control and communicate with robot-arms, the source laser and cameras to implement image acquisition. Algorithms were developed so that the defect sizes can be correctly evaluated and these have been confirmed using test samples. Individual inspection images can also be stitched together for a single bead, a layer of beads or multiple layers of beads so that defects can be mapped through the additive process. A mathematical model was built up to analyze and evaluate the movement of heat throughout the inspection bead. Inspection processes were developed and positional and temporal gradient algorithms have been used to measure the flaw sizes. Defect analysis is then performed to determine if the defect(s) can be further classified (crack, lack of fusion, porosity) and the sentencing engine then compares the most significant defect or group of defects against the acceptance criteria - independent of human decisions. Testing on manufactured defects from the EC funded INTRAPID project has successful detected and correctly sentenced all samples.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... repetitive detailed inspections for disbonding and cracking of the fuselage inner doubler; eddy current and... detailed inspections for disbonding and cracking of the fuselage inner doubler; eddy current and ultrasonic... or Modification if Necessary (g) For airplanes on which an eddy current inspection of the ``special...
Catalysts for Lightweight Solar Fuels Generation
2017-03-10
single bandgap solar cells to OER catalysts could lead to very high solar -to-fuel efficiencies. Figure 3 illustrates a PV -EC utilizing a PV , an...3- or 4 -single junction c-Si solar cells connected in series. Considering a PV -EC device based on commercially available single junction-Si solar ...30.8%) with open circuit voltage and short circuit current density ; total plot area is scaled to incident solar power (100 mW cm–2). The PV -EC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khaleel, Mohammad A.; Lin, Zijing; Singh, Prabhakar
2004-05-03
A 3D simulation tool for modeling solid oxide fuel cells is described. The tool combines the versatility and efficiency of a commercial finite element analysis code, MARC{reg_sign}, with an in-house developed robust and flexible electrochemical (EC) module. Based upon characteristic parameters obtained experimentally and assigned by the user, the EC module calculates the current density distribution, heat generation, and fuel and oxidant species concentration, taking the temperature profile provided by MARC{reg_sign} and operating conditions such as the fuel and oxidant flow rate and the total stack output voltage or current as the input. MARC{reg_sign} performs flow and thermal analyses basedmore » on the initial and boundary thermal and flow conditions and the heat generation calculated by the EC module. The main coupling between MARC{reg_sign} and EC is for MARC{reg_sign} to supply the temperature field to EC and for EC to give the heat generation profile to MARC{reg_sign}. The loosely coupled, iterative scheme is advantageous in terms of memory requirement, numerical stability and computational efficiency. The coupling is iterated to self-consistency for a steady-state solution. Sample results for steady states as well as the startup process for stacks with different flow designs are presented to illustrate the modeling capability and numerical performance characteristic of the simulation tool.« less
NASA Astrophysics Data System (ADS)
Ji, Jinghua; Luo, Jianhua; Lei, Qian; Bian, Fangfang
2017-05-01
This paper proposed an analytical method, based on conformal mapping (CM) method, for the accurate evaluation of magnetic field and eddy current (EC) loss in fault-tolerant permanent-magnet (FTPM) machines. The aim of modulation function, applied in CM method, is to change the open-slot structure into fully closed-slot structure, whose air-gap flux density is easy to calculate analytically. Therefore, with the help of Matlab Schwarz-Christoffel (SC) Toolbox, both the magnetic flux density and EC density of FTPM machine are obtained accurately. Finally, time-stepped transient finite-element method (FEM) is used to verify the theoretical analysis, showing that the proposed method is able to predict the magnetic flux density and EC loss precisely.
Innovative Sensors for Pipeline Crawlers: Rotating Permanent Magnet Inspection
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Bruce Nestleroth; Richard J. Davis; Stephanie Flamberg
2006-09-30
Internal inspection of pipelines is an important tool for ensuring safe and reliable delivery of fossil energy products. Current inspection systems that are propelled through the pipeline by the product flow cannot be used to inspect all pipelines because of the various physical barriers they may encounter. To facilitate inspection of these ''unpiggable'' pipelines, recent inspection development efforts have focused on a new generation of powered inspection platforms that are able to crawl slowly inside a pipeline and can maneuver past the physical barriers that limit internal inspection applicability, such as bore restrictions, low product flow rate, and low pressure.more » The first step in this research was to review existing inspection technologies for applicability and compatibility with crawler systems. Most existing inspection technologies, including magnetic flux leakage and ultrasonic methods, had significant implementation limitations including mass, physical size, inspection energy coupling requirements and technology maturity. The remote field technique was the most promising but power consumption was high and anomaly signals were low requiring sensitive detectors and electronics. After reviewing each inspection technology, it was decided to investigate the potential for a new inspection method. The new inspection method takes advantage of advances in permanent magnet strength, along with their wide availability and low cost. Called rotating permanent magnet inspection (RPMI), this patent pending technology employs pairs of permanent magnets rotating around the central axis of a cylinder to induce high current densities in the material under inspection. Anomalies and wall thickness variations are detected with an array of sensors that measure local changes in the magnetic field produced by the induced current flowing in the material. This inspection method is an alternative to the common concentric coil remote field technique that induces low-frequency eddy currents in ferromagnetic pipes and tubes. Since this is a new inspection method, both theory and experiment were used to determine fundamental capabilities and limitations. Fundamental finite element modeling analysis and experimental investigations performed during this development have led to the derivation of a first order analytical equation for designing rotating magnetizers to induce current and positioning sensors to record signals from anomalies. Experimental results confirm the analytical equation and the finite element calculations provide a firm basis for the design of RPMI systems. Experimental results have shown that metal loss anomalies and wall thickness variations can be detected with an array of sensors that measure local changes in the magnetic field produced by the induced current flowing in the material. The design exploits the phenomenon that circumferential currents are easily detectable at distances well away from the magnets. Current changes at anomalies were detectable with commercial low cost Hall Effect sensors. Commercial analog to digital converters can be used to measure the sensor output and data analysis can be performed in real time using PC computer systems. The technology was successfully demonstrated during two blind benchmark tests where numerous metal loss defects were detected. For this inspection technology, the detection threshold is a function of wall thickness and corrosion depth. For thinner materials, the detection threshold was experimentally shown to be comparable to magnetic flux leakage. For wall thicknesses greater than three tenths of an inch, the detection threshold increases with wall thickness. The potential for metal loss anomaly sizing was demonstrated in the second benchmarking study, again with accuracy comparable to existing magnetic flux leakage technologies. The rotating permanent magnet system has the potential for inspecting unpiggable pipelines since the magnetizer configurations can be sufficiently small with respect to the bore of the pipe to pass obstructions that limit the application of many inspection technologies. Also, since the largest dimension of the Hall Effect sensor is two tenths of an inch, the sensor packages can be small, flexible and light. The power consumption, on the order of ten watts, is low compared to some inspection systems; this would enable autonomous systems to inspect longer distances between charges. This project showed there are no technical barriers to building a field ready unit that can pass through narrow obstructions, such as plug valves. The next step in project implementation is to build a field ready unit that can begin to establish optimal performance capabilities including detection thresholds, sizing capability, and wall thickness limitations.« less
Multiplexed HTS rf SQUID magnetometer array for eddy current testing of aircraft rivet joints
NASA Astrophysics Data System (ADS)
Gärtner, S.; Krause, H.-J.; Wolters, N.; Lomparski, D.; Wolf, W.; Schubert, J.; Kreutzbruck, M. v.; Allweins, K.
2002-05-01
Using three rf SQUID magnetometers, a multiplexed SQUID array was implemented. The SQUIDs are positioned in line with 7 mm spacing and operated using one feedback electronics with sequential read out demodulation at different radio frequencies (rf). The cross-talk between SQUID channels was determined to be negligible. To show the performance of the SQUID array, eddy current (EC) measurements of aluminum aircraft samples in conjunction with a differential (double-D) EC excitation and lock-in readout were carried out. With computer-controlled continuous switching of the SQUIDs during the scan, three EC signal traces of the sample are obtained simultaneously. We performed measurements with an EC excitation frequency of 135 Hz to localize an artificial crack (sawcut flaw) of 20 mm length in an aluminum sheet with 0.6 mm thickness. The flaw was still detected when covered with aluminum of up to 10 mm thickness. In addition, measurements with varying angles between scanning direction and flaw orientation are presented.
Precise on-machine extraction of the surface normal vector using an eddy current sensor array
NASA Astrophysics Data System (ADS)
Wang, Yongqing; Lian, Meng; Liu, Haibo; Ying, Yangwei; Sheng, Xianjun
2016-11-01
To satisfy the requirements of on-machine measurement of the surface normal during complex surface manufacturing, a highly robust normal vector extraction method using an Eddy current (EC) displacement sensor array is developed, the output of which is almost unaffected by surface brightness, machining coolant and environmental noise. A precise normal vector extraction model based on a triangular-distributed EC sensor array is first established. Calibration of the effects of object surface inclination and coupling interference on measurement results, and the relative position of EC sensors, is involved. A novel apparatus employing three EC sensors and a force transducer was designed, which can be easily integrated into the computer numerical control (CNC) machine tool spindle and/or robot terminal execution. Finally, to test the validity and practicability of the proposed method, typical experiments were conducted with specified testing pieces using the developed approach and system, such as an inclined plane and cylindrical and spherical surfaces.
42 CFR 486.110 - Condition for coverage: Inspection of equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition for coverage: Inspection of equipment... coverage: Inspection of equipment. Inspections of all X-ray equipment and shielding are made by qualified... supplier maintains records of current inspections which include the extent to which equipment and shielding...
14 CFR 65.92 - Inspection authorization: Duration.
Code of Federal Regulations, 2012 CFR
2012-01-01
... (CONTINUED) AIRMEN CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.92 Inspection... effective mechanic certificate with both a currently effective airframe rating and a currently effective...
14 CFR 65.92 - Inspection authorization: Duration.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (CONTINUED) AIRMEN CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.92 Inspection... effective mechanic certificate with both a currently effective airframe rating and a currently effective...
14 CFR 65.92 - Inspection authorization: Duration.
Code of Federal Regulations, 2013 CFR
2013-01-01
... (CONTINUED) AIRMEN CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.92 Inspection... effective mechanic certificate with both a currently effective airframe rating and a currently effective...
14 CFR 65.92 - Inspection authorization: Duration.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (CONTINUED) AIRMEN CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.92 Inspection... effective mechanic certificate with both a currently effective airframe rating and a currently effective...
14 CFR 65.92 - Inspection authorization: Duration.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (CONTINUED) AIRMEN CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.92 Inspection... effective mechanic certificate with both a currently effective airframe rating and a currently effective...
Byamugisha, Josaphat K; Mirembe, Florence M; Faxelid, Elisabeth; Gemzell-Danielsson, Kristina
2007-01-01
Health care workers (HCWs) play an important role in making emergency contraceptives (ECs) available to clients. They can influence accessibility positively through counselling, prescribing or advocating the use of ECs. However, in some settings, HCWs have been blamed for unfavourable attitudes and lack of accurate information. Objective. To assess the knowledge, attitudes and prescribing pattern of EC by HCWs in Kampala district, Uganda. The total number of health units at different levels of health care delivery in Kampala (894) was obtained. Probability proportional to size (PPS) technique of sampling was applied. Some 247 HCWs completed a self-administered questionnaire on their knowledge about EC, including methods, mechanism of action, prescription of EC, sources of information, attitudes towards EC, and if and how it should be made available. Of the HCWs, 80% had knowledge of ECs. However, 1 in every 4 was not sure about the time limit within which EC is effective. A total of 50% of the participants had obtained information from a physician (26.4%) or from a training school (24%). The Yuzpe regimen was the most commonly mentioned and prescribed method of EC. The HCWs attitudes to EC were generally positive, and it was suggested that the community should be informed and sensitised about EC. There was a significant difference between having had a family planning educational update or not in the last year and knowledge of EC (p=0.005). Most HCWs were aware of EC, but some lacked important knowledge on its use or available methods. HCWs should have regular (annual) in-service training in reproductive health issues, such as counselling on EC. This will enable them to keep up to date with the current evidence-based recommendations in the field of contraceptive technology.
Blagojevic, Bojan; Dadios, Nikolaos; Reinmann, Karin; Guitian, Javier; Stärk, Katharina D C
2015-06-01
The changes in detection of selected public and animal health as well as welfare hazards due to the change in current inspection of green offal in cattle, small ruminants and pigs were assessed. With respect to public health and animal health, the conditional likelihood of detection with the current green offal inspection was found to be low for eleven out of the twenty-four selected hazard-species pairings and very low for the remaining thirteen pairings. This strongly suggests that the contribution of current green offal inspection to risk mitigation is very limited for public and animal health hazards. The removal of green offal inspection would reduce the detection of some selected animal welfare conditions. For all selected public and animal health as well as welfare hazards, the reduced detection could be compensated with other pre-harvest, harvest and/or post-harvest control measures including existing meat inspection tasks. Copyright © 2015 Elsevier Ltd. All rights reserved.
Apparatus For Eddy-Current Inspection Of Bolts
NASA Technical Reports Server (NTRS)
Amos, Jay M.
1994-01-01
Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.
22 CFR 212.23 - Current index.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Current index. 212.23 Section 212.23 Foreign... Inspection and Copying § 212.23 Current index. USAID maintains and makes available for public inspection and copying a current index providing identifying information for the public as to any matter which has been...
Integrated light maintenance and inspection system for high-mast poles.
DOT National Transportation Integrated Search
2005-01-01
Virginia highway high-mast light poles must be inspected periodically for structural defects to prevent failures. The visual inspection methods currently used include use of binoculars and telescopes and up-close inspection with bucket trucks. These ...
Hajek, Peter; Etter, Jean-François; Benowitz, Neal; Eissenberg, Thomas; McRobbie, Hayden
2015-01-01
Aims We reviewed available research on the use, content and safety of electronic cigarettes (EC) and on their effects on users, to assess their potential for harm or benefit and to extract evidence that can guide future policy. Methods Studies were identified by systematic database searches and screening references to February 2014. Results EC aerosol can contain some of the toxicants present in tobacco smoke, but at levels which are much lower. Long-term health effects of EC use are unknown but compared with cigarettes, EC are likely to be much less, if at all, harmful to users or bystanders. EC are increasingly popular among smokers, but to date there is no evidence of regular use by never-smokers or by non-smoking children. EC enable some users to reduce or quit smoking. Conclusions Allowing EC to compete with cigarettes in the marketplace might decrease smoking-related morbidity and mortality. Regulating EC as strictly as cigarettes, or even more strictly as some regulators propose, is not warranted on current evidence. Health professionals may consider advising smokers unable or unwilling to quit through other routes to switch to EC as a safer alternative to smoking and a possible pathway to complete cessation of nicotine use. PMID:25078252
Bakhsh, Salwa; Kinloch, Mary; Hoang, Lien N; Soslow, Robert A; Köbel, Martin; Lee, Cheng-Han; McAlpine, Jessica N; McConechy, Melissa K; Gilks, C Blake
2016-05-01
To characterize the histomorphological features of endometrial carcinomas (ECs) harbouring polymerase ε (POLE) mutations. Forty-three ECs with POLE mutations were compared with a cohort of 202 ECs. Most POLE-mutated ECs were endometrioid [34/43 (79%)]; the remaining tumours were mixed [6/43 (14%)], serous [2/43 (5%)], and clear cell [1/43 (2%)]. The endometrioid carcinomas were predominantly International Federation of Gynecology and Obstetrics grade 3 (27/43, 63%). The histotype distribution did not differ from that of control ECs (P = 0.69), but the grade of the EC was higher (P < 0.0005). Both nuclear grade and mitotic index were significantly higher in POLE-mutated ECs than in the comparison cohort. POLE-mutated ECs were associated with peritumoral lymphocytes and numerous tumour-infiltrating lymphocytes. Lymphovascular invasion was present in 20 of 43 tumours. Adjuvant radiotherapy and adjuvant chemotherapy would be offered in up to 80% and 40% of patients, respectively, on the basis of stage, grade, lymphovascular invasion, and histotype. POLE-mutated ECs are typically of high grade, with prominent lymphocytic infiltration, but they are not sufficiently distinctive to allow accurate diagnosis based on routine haematoxylin and eosin staining. Even though POLE-mutated tumours are associated with an excellent prognosis, current guidelines for giving adjuvant treatment for EC result in most patients receiving adjuvant therapy. © 2015 John Wiley & Sons Ltd.
Bahrndorff, Simon; Michaelsen, Thomas Yssing; Jensen, Anne; Marcussen, Laurits Faarup; Nielsen, Majken Elley; Roslev, Peter
2016-07-01
Aquatic pollutants are often biologically active at low concentrations and impact on biota in combination with other abiotic stressors. Traditional toxicity tests may not detect these effects, and there is a need for sensitive high-throughput methods for detecting sublethal effects. We have evaluated an automated infra-red (IR) light-based monitor for recording the swimming activity of Daphnia magna to establish temporal patterns of toxicant effects on an individual level. Activity was recorded for 48 h and the sensitivity of the monitor was evaluated by exposing D. magna to the reference chemicals K2 Cr2 O7 at 15, 20 and 25 °C and 2,4-dichlorophenol at 20 °C. Significant effects (P < 0.001) of toxicant concentrations, exposure time and incubation temperatures were observed. At 15 °C, the swimming activity remained unchanged for 48 h at sublethal concentrations of K2 Cr2 O7 whereas activity at 20 and 25 °C was more biphasic with decreases in activity occurring after 12-18 h. A similar biphasic pattern was observed after 2,4-dichlorophenol exposure at 20 °C. EC50 values for 2,4-dichlorophenol and K2 Cr2 O7 determined from automated recording of swimming activity showed increasing toxicity with time corresponding to decreases in EC50 of 0.03-0.07 mg l(-1) h(-1) . EC50 values determined after 48 h were comparable or lower than EC50 values based on visual inspection according to ISO 6341. The results demonstrated that the swimming activity monitor is capable of detecting sublethal behavioural effects that are toxicant and temperature dependent. The method allows EC values to be established at different time points and can serve as a high-throughput screening tool in toxicity testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Gawronski, Bertram; Mitchell, Derek G V; Balas, Robert
2015-10-01
Evaluative conditioning (EC) is defined as the change in the evaluation of a conditioned stimulus (CS) because of its pairing with a valenced unconditioned stimulus (US). Counter to views that EC is the product of automatic learning processes, recent research has revealed various characteristics of nonautomatic processing in EC. The current research investigated the controllability of EC by testing the effectiveness of 3 emotion-focused strategies in preventing the acquisition of conditioned preferences: (a) suppression of emotional reactions to the US, (b) reappraisal of the valence of the US, and (c) facial blocking of emotional responses. Although all 3 strategies reduced EC effects on self-reported evaluations by impairing recollective memory for CS-US pairings, they were ineffective in reducing EC effects on an evaluative priming measure. Regardless of the measure, effective control did not depend on the level of arousal elicited by the US. The results suggest that the 3 strategies can influence deliberate CS evaluations through memory-related processes, but they are ineffective in reducing EC effects on spontaneous evaluative responses. Implications for mental process theories of EC are discussed. (c) 2015 APA, all rights reserved).
Interactions of Human Endothelial and Multipotent Mesenchymal Stem Cells in Cocultures
Ern, Christina; Krump-Konvalinkova, Vera; Docheva, Denitsa; Schindler, Stefanie; Rossmann, Oliver; Böcker, Wolfgang; Mutschler, Wolf; Schieker, Matthias
2010-01-01
Current strategies for tissue engineering of bone rely on the implantation of scaffolds, colonized with human mesenchymal stem cells (hMSC), into a recipient. A major limitation is the lack of blood vessels. One approach to enhance the scaffold vascularisation is to supply the scaffolds with endothelial cells (EC). The main goal of this study was to establish a coculture system of hMSC and EC for the purposes of bone tissue engineering. Therefore, the cell behaviour, proliferation and differentiation capacity in various cell culture media as well as cell interactions in the cocultures were evaluated. The differentiation capacity of hMSC along osteogenic, chondrogenic, and adipogenic lineage was impaired in EC medium while in a mixed EC and hMSC media, hMSC maintained osteogenic differentiation. In order to identify and trace EC in the cocultures, EC were transduced with eGFP. Using time-lapse imaging, we observed that hMSC and EC actively migrated towards cells of their own type and formed separate clusters in long term cocultures. The scarcity of hMSC and EC contacts in the cocultures suggest the influence of growth factor-mediated cell interactions and points to the necessity of further optimization of the coculture conditions. PMID:21625373
Stahl, Christoph; Unkelbach, Christian; Corneille, Olivier
2009-09-01
Evaluative conditioning (EC) is a central mechanism for both classic and current theories of attitude formation. In contrast to Pavlovian conditioning, it is often conceptualized as a form of evaluative learning that occurs without awareness of the conditioned stimulus-unconditioned stimulus (CS-US) contingencies. In the present research, the authors directly address this point by assessing the respective roles of US valence awareness and US identity awareness in attitude formation through EC. Across 4 experiments, EC was assessed with evaluative ratings as well as evaluative priming measures, and the impact of valence and identity awareness on EC was evaluated. EC effects on priming and rating measures occurred only for CSs for which participants could report the associated US valence, and US identity awareness did not further contribute to EC. This finding was obtained both for semantically meaningless (i.e., nonword letter sequences) and meaningful (i.e., consumer products) CSs. These results provide further support for the critical role of contingency awareness in EC, albeit valence awareness, not identity awareness. (c) 2009 APA, all rights reserved).
Temporal and spatial variations of sea surface temperature in the East China Sea
NASA Astrophysics Data System (ADS)
Tseng, Chente; Lin, Chiyuan; Chen, Shihchin; Shyu, Chungzen
2000-03-01
Sea surface temperature of the East China Sea (ECS) were analyzed using the NOAA/AVHRR SST images. These satellite images reveal surface features of ECS including mainly the Kuroshio Current, Kuroshio Branch Current, Taiwan Warm Current, China coastal water, Changjiang diluted water and Yellow Sea mixed cold water. The SST of ECS ranges from 27 to 29°C in summer; some cold eddies were found off northeast Taiwan and to the south of Changjiang mouth. SST anomalies at the center of these eddies were about 2-5°C. The strongest front usually occurs in May each year and its temperature gradient is about 5-6°C over a cross-shelf distance of 30 nautical miles. The Yellow Sea mixed cold water also provides a contrast from China Coastal waters shoreward of the 50 m isobath; cross-shore temperature gradient is about 6-8°C over 30 nautical miles. The Kuroshio intrudes into ECS preferably at two locations. The first is off northeast Taiwan; the subsurface water of Kuroshio is upwelled onto the shelf while the main current is deflected seaward. The second site is located at 31°N and 128°E, which is generally considered as the origin of the Tsushima Warm Current. More quantitatively, a 2-year time series of monthly SST images is examined using EOF analysis to determine the spatial and temporal variations in the northwestern portion of ECS. The first spatial EOF mode accounts for 47.4% of total spatial variance and reveals the Changjiang plume and coastal cold waters off China. The second and third EOF modes account for 16.4 and 9.6% of total variance, respectively, and their eigenvector images show the intrusion of Yellow Sea mixed cold waters and the China coastal water. The fourth EOF mode accounts for 5.4% of total variance and reveals cold eddies around Chusan Islands. The temporal variance EOF analysis is less revealing in this study area.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-08
... AW139 helicopters. The existing AD currently requires inspecting the fuselage frame to detect fatigue... interval for inspecting the fuselage frame for a fatigue crack. This proposed AD would require inspecting... detect a fatigue crack that could result in failure of the fuselage frame and subsequent loss of control...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-02
... airplanes. This AD requires repetitive detailed and high frequency eddy current inspections of the forward... high frequency eddy current (HFEC) inspections of the forward and aft sides of the strut front spar... date of this AD, whichever occurs later: Perform a detailed inspection and a high frequency eddy...
Diaz, Anjolii; Eisenberg, Nancy; Valiente, Carlos; VanSchyndel, Sarah; Spinrad, Tracy L.; Berger, Rebecca; Hernandez, Maciel M.; Silva, Kassondra M.; Southworth, Jody
2015-01-01
The current study examined the role of naturally-occurring negative and positive emotion expressivity in kindergarten and children’s effortful control (EC) on their relationships with teachers, academic engagement, and problems behaviors in school. Further, the potential moderating role of EC on these important school outcomes was assessed. Emotion and engagement were observed at school. EC was assessed by multiple methods. Teachers reported on their student–teacher relationships and student’s externalizing behaviors. Children’s emotion expressivity and EC were related to engagement and relationships with teachers as well as behavioral problems at school. Children low in EC may be particularly vulnerable to the poor outcomes associated with relatively intense emotion expressivity as they struggle to manage their emotions and behaviors in the classroom. PMID:28584388
Xia, Guobin; Hong, Shan; Liu, Songbai
2014-05-15
Simultaneous preparation of naturally rare catechins, EGC and EC, has been realized by tannase-mediated biotransformation combining high speed counter current chromatography. In addition, simultaneous preparation of the four catechins, EGCG, ECG, EGC, and EC in green tea extract has also been achieved by HSCCC under the normal phase and the reversed phase modes. The identity of the catechins was determined by HPLC-DAD-ESI-MS and quantification of the catechins was performed by HPLC-DAD. In a typical HSCCC separation, 27.2 mg 98.8% EGCG, 14.1 mg 94.7% EGC, and 9.3 mg 97.5% EC were obtained. This new method is efficient, time-saving and valuable for biological studies. Copyright © 2013 Elsevier Ltd. All rights reserved.
[Advance in study of vascular endothelial cell and smooth muscle cell co-culture system].
Li, Yujie; Yang, Qing; Weng, Xiaogang; Chen, Ying; Ruan, Congxiao; Li, Dan; Zhu, Xiaoxing
2012-02-01
The interactions between endothelial cells (EC) and smooth muscle cells (SMC) contribute to vascular physiological functions and also cause the occurrence and development of different kinds of diseases. Currently, EC-SMC co-culture model is the best way to study the interactions between the two kinds of cells. This article summarizes existing EC-SMC co-culture models and their effects on the structure and functions of the two kinds of cells. Microscopically speaking, it provides a basis for in-depth studies on their interactions as well as a reference for the establishment of in vitro EC-SMC co-culture system that is closer to organic physiology or pathology state.
Cendejas, Richard A; Phillips, Mark C; Myers, Tanya L; Taubman, Matthew S
2010-12-06
An external-cavity (EC) quantum cascade (QC) laser using optical feedback from a partial-reflector is reported. With this configuration, the otherwise multi-mode emission of a Fabry-Perot QC laser was made single-mode with optical output powers exceeding 40 mW. A mode-hop free tuning range of 2.46 cm(-1) was achieved by synchronously tuning the EC length and QC laser current. The linewidth of the partial-reflector EC-QC laser was measured for integration times from 100 μs to 4 seconds, and compared to a distributed feedback QC laser. Linewidths as small as 480 kHz were recorded for the EC-QC laser.
van der Westhuizen, Claire; Wyatt, Gail; Williams, John K.; Stein, Dan J.; Sorsdahl, Katherine
2014-01-01
Little is known about the prevalence and predictors of mental disorders amongst injured emergency centre (EC) patients in low- and middle-income countries. Patients presenting with either an intentional or unintentional injury were recruited (n=200). Mental health, injury and psychological trauma histories were assessed. Descriptive statistics and logistic regressions were conducted and predictors for current mental disorder were identified. Diagnostic criteria for a current mental disorder, including substance use disorders, were met by 59.5% of participants. Compared to those with an unintentional injury, intentionally injured participants were more likely to be diagnosed with a current mental disorder (66.9% vs 48.8%; p=0.01). High frequencies of previous intentional injuries predicted for current mental disorder (OR = 1.460, 95% CI 1.08-1.98), while male gender and witnessed community violence predicted substance use disorder diagnoses. Findings indicate that injured EC patients, particularly those with intentional injuries, are at risk for mental disorders. Psychosocial interventions in the EC context can potentially make an important contribution in reducing the burden of mental disorders and injuries in low- and middle-income countries. PMID:25126754
Modeling human endothelial cell transformation in vascular neoplasias
Wen, Victoria W.; MacKenzie, Karen L.
2013-01-01
Endothelial cell (EC)-derived neoplasias range from benign hemangioma to aggressive metastatic angiosarcoma, which responds poorly to current treatments and has a very high mortality rate. The development of treatments that are more effective for these disorders will be expedited by insight into the processes that promote abnormal proliferation and malignant transformation of human ECs. The study of primary endothelial malignancy has been limited by the rarity of the disease; however, there is potential for carefully characterized EC lines and animal models to play a central role in the discovery, development and testing of molecular targeted therapies for vascular neoplasias. This review describes molecular alterations that have been identified in EC-derived neoplasias, as well as the processes that underpin the immortalization and tumorigenic conversion of ECs. Human EC lines, established through the introduction of defined genetic elements or by culture of primary tumor tissue, are catalogued and discussed in relation to their relevance as models of vascular neoplasia. PMID:24046386
Don't Worry, Be Happy: Endocannabinoids and Cannabis at the Intersection of Stress and Reward.
Volkow, Nora D; Hampson, Aidan J; Baler, Ruben D
2017-01-06
Cannabis enables and enhances the subjective sense of well-being by stimulating the endocannabinoid system (ECS), which plays a key role in modulating the response to stress, reward, and their interactions. However, over time, repeated activation of the ECS by cannabis can trigger neuroadaptations that may impair the sensitivity to stress and reward. This effect, in vulnerable individuals, can lead to addiction and other adverse consequences. The recent shift toward legalization of medical or recreational cannabis has renewed interest in investigating the physiological role of the ECS as well as the potential health effects, both adverse and beneficial, of cannabis. Here we review our current understanding of the ECS and its complex physiological roles. We discuss the implications of this understanding vis-á-vis the ECS's modulation of stress and reward and its relevance to mental disorders in which these processes are disrupted (i.e., addiction, depression, posttraumatic stress disorder, schizophrenia), along with the therapeutic potential of strategies to manipulate the ECS for these conditions.
Nitrogen removal from the saline sludge liquor by electrochemical denitrification.
Xie, Z M; Li, X Y; Chan, K Y
2006-01-01
Sludge liquor from the sludge dewatering process has a high ammonia content. In the present study, a lab-scale electrochemical (EC) system with a pair of Ti electrode plates was used for treating the sludge centrate liquor of digested wastewater sludge with a NH4(+) - N content of around 500 mg/L. The sludge liquor had a high salinity due to seawater being used for toilet flushing in Hong Kong. The results show that the EC process is highly effective for denitrification of the saline sludge liquor. Complete nitrogen removal could be achieved within 1 hr or so. The rate of EC denitrification increased with the current intensity applied. The best current efficiency for nitrogen removal was obtained for a gap distance between the electrodes at 8 mm. Electro-chlorination was considered to be the major mechanism of EC denitrification. The formation of chlorination by-products (CBPs) appeared to be minimal with the total trihalomethanes (THM) detected at a level of 300 microg/L or lower. The power consumption for EC denitrification was around 23 kWh/kg N. Additional electro-flocculation with a pair of iron needle electrodes could enhance the flocculation and subsequent sedimentation of colloidal organics in the sludge liquor, increasing the organic removal from less than 30% to more than 70%. Therefore, the EC process including both electro-denitrification and electro-flocculation can be developed as the most cost-effective method for treatment of the saline sludge liquor.
Status of the ITER Electron Cyclotron Heating and Current Drive System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darbos, Caroline; Albajar, Ferran; Bonicelli, Tullio
2015-10-07
We present that the electron cyclotron (EC) heating and current drive (H&CD) system developed for the ITER is made of 12 sets of high-voltage power supplies feeding 24 gyrotrons connected through 24 transmission lines (TL), to five launchers, four located in upper ports and one at the equatorial level. Nearly all procurements are in-kind, following general ITER philosophy, and will come from Europe, India, Japan, Russia and the USA. The full system is designed to couple to the plasma 20 MW among the 24 MW generated power, at the frequency of 170 GHz, for various physics applications such as plasmamore » start-up, central H&CD and magnetohydrodynamic (MHD) activity control. The design takes present day technology and extends toward high-power continuous operation, which represents a large step forward as compared to the present state of the art. The ITER EC system will be a stepping stone to future EC systems for DEMO and beyond.The development of the EC system is facing significant challenges, which includes not only an advanced microwave system but also compliance with stringent requirements associated with nuclear safety as ITER became the first fusion device licensed as basic nuclear installations as of 9 November 2012. Finally, since the conceptual design of the EC system was established in 2007, the EC system has progressed to a preliminary design stage in 2012 and is now moving forward toward a final design.« less
Nguyen, Dinh Duc; Yoon, Yong Soo; Bui, Xuan Thanh; Kim, Sung Su; Chang, Soon Woong; Guo, Wenshan; Ngo, Huu Hao
2017-11-01
Performance of an electrocoagulation (EC) process in batch and continuous operating modes was thoroughly investigated and evaluated for enhancing wastewater phosphorus removal under various operating conditions, individually or combined with initial phosphorus concentration, wastewater conductivity, current density, and electrolysis times. The results revealed excellent phosphorus removal (72.7-100%) for both processes within 3-6 min of electrolysis, with relatively low energy requirements, i.e., less than 0.5 kWh/m 3 for treated wastewater. However, the removal efficiency of phosphorus in the continuous EC operation mode was better than that in batch mode within the scope of the study. Additionally, the rate and efficiency of phosphorus removal strongly depended on operational parameters, including wastewater conductivity, initial phosphorus concentration, current density, and electrolysis time. Based on experimental data, statistical model verification of the response surface methodology (RSM) (multiple factor optimization) was also established to provide further insights and accurately describe the interactive relationship between the process variables, thus optimizing the EC process performance. The EC process using iron electrodes is promising for improving wastewater phosphorus removal efficiency, and RSM can be a sustainable tool for predicting the performance of the EC process and explaining the influence of the process variables.
Xu, Dan; Maier, Joseph K; King, Kevin F; Collick, Bruce D; Wu, Gaohong; Peters, Robert D; Hinks, R Scott
2013-11-01
The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically have significant high order spatial components that cannot be compensated by preemphasis. High order ECs are first calibrated at the system level in a protocol independent fashion. The resulting amplitudes and time constants of high order ECs can then be used to calculate imaging protocol specific corrections. A combined prospective and retrospective approach is proposed to apply correction during data acquisition and image reconstruction. Various phantom, brain, body, and whole body diffusion weighted images with and without the proposed method are acquired. Significantly reduced image distortion and misregistration are consistently seen in images with the proposed method compared with images without. The proposed method is a powerful (e.g., effective at 48 cm field of view and 30 cm slice coverage) and flexible (e.g., compatible with other image enhancements and arbitrary scan plane) technique to correct high order ECs induced distortion and misregistration for various diffusion weighted echo planar imaging applications, without the need for further image post processing, protocol dependent prescan, or sacrifice in signal-to-noise ratio. Copyright © 2013 Wiley Periodicals, Inc.
Guo, Jia; Meakin, James A; Jezzard, Peter; Wong, Eric C
2015-03-01
Velocity-selective arterial spin labeling (VSASL) tags arterial blood on a velocity-selective (VS) basis and eliminates the tagging/imaging gap and associated transit delay sensitivity observed in other ASL tagging methods. However, the flow-weighting gradient pulses in VS tag preparation can generate eddy currents (ECs), which may erroneously tag the static tissue and create artificial perfusion signal, compromising the accuracy of perfusion quantification. A novel VS preparation design is presented using an eight-segment B1 insensitive rotation with symmetric radio frequency and gradient layouts (sym-BIR-8), combined with delays after gradient pulses to optimally reduce ECs of a wide range of time constants while maintaining B0 and B1 insensitivity. Bloch simulation, phantom, and in vivo experiments were carried out to determine robustness of the new and existing pulse designs to ECs, B0 , and B1 inhomogeneity. VSASL with reduced EC sensitivity across a wide range of EC time constants was achieved with the proposed sym-BIR-8 design, and the accuracy of cerebral blood flow measurement was improved. The sym-BIR-8 design performed the most robustly among the existing VS tagging designs, and should benefit studies using VS preparation with improved accuracy and reliability. © 2014 Wiley Periodicals, Inc.
Characterization of Arctic elemental carbon in Barrow, AK using radiocarbon source apportionment
NASA Astrophysics Data System (ADS)
Barrett, T. E.; Usenko, S.; Robinson, E. M.; Sheesley, R. J.
2013-12-01
Currently, the Arctic is one of the fastest warming regions on earth with surface temperatures increasing at a rate nearly double the global mean over recent decades. Despite the fact that atmospheric concentrations of elemental carbon (EC) are lower in the Arctic than in lower latitudes, deposition of EC on snow and ice may exacerbate regional warming by simultaneously decreasing albedo and increasing melt rates. Due to the intensifying Arctic oil exploration in areas such as the Beaufort and Chukchi seas, the impact of new emission sources such as heavy fuel and heavy diesel combustion on regional carbon needs to be assessed. The first step in developing mitigation strategies for reducing current and future EC emissions in the Arctic is to determine emission source contributions. This study aims to determine the relative contributions of fossil fuel and biomass combustion and to identify major source regions of EC to the Arctic. Radiocarbon analysis of both total organic carbon (TOC) and EC combined with organic tracer and back trajectory analysis has been applied to a set of wintertime coarse particulate matter (PM10) samples from Barrow, AK. Preliminary apportionment for January 2013 indicates roughly half of TOC is from biogenic/biomass burning emissions and one third of EC is due to biomass burning emissions. The radiocarbon results will be combined with organic tracer analysis (polycyclic aromatic hydrocarbons, petroleum biomarkers and normal alkanes), increasing the specificity of the relative contribution of both the fossil and modern (biogenic/biomass burning) carbon emission sources. This research represents the first reported radiocarbon values for Arctic EC, providing highly conclusive source apportionment prior to the influence of increased drilling operations and ship traffic in the Beaufort and Chukchi seas.
Additive Manufacturing Infrared Inspection
NASA Technical Reports Server (NTRS)
Gaddy, Darrell; Nettles, Mindy
2015-01-01
The Additive Manufacturing Infrared Inspection Task started the development of a real-time dimensional inspection technique and digital quality record for the additive manufacturing process using infrared camera imaging and processing techniques. This project will benefit additive manufacturing by providing real-time inspection of internal geometry that is not currently possible and reduce the time and cost of additive manufactured parts with automated real-time dimensional inspections which deletes post-production inspections.
Development of inspection robots for bridge cables.
Yun, Hae-Bum; Kim, Se-Hoon; Wu, Liuliu; Lee, Jong-Jae
2013-01-01
This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.
Process Specification for Eddy Current Inspection
NASA Technical Reports Server (NTRS)
Koshti, Ajay
2011-01-01
This process specification establishes the minimum requirements for eddy current inspection of flat surfaces, fastener holes, threaded fasteners and seamless and welded tubular products made from nonmagnetic alloys such as aluminum and stainless steel.
78 FR 22215 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-15
... necessary; a one-time eddy current inspection of certain fastener holes for cracking, and repair if... realignment if necessary; a one-time eddy current inspection of certain fastener holes for cracking, and...
77 FR 26993 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-08
... high frequency eddy current (HFEC) inspections for cracking in holes common to the splice strap and... tasks required by this paragraph: Before further flight, do a high frequency eddy current (HFEC... approval must specifically refer to this AD. (h) Detailed and High Frequency Eddy Current Inspections...
Organic pollutant removal from edible oil process wastewater using electrocoagulation
NASA Astrophysics Data System (ADS)
Sharma, S.; Can, O. T.; Hammed, M.; Nawarathna, D.; Simsek, H.
2018-03-01
Wastewaters generated from vegetable oil industries contain a high concentration of organic pollutants that are detrimental to the aquatic ecosystem. Electrochemical processes are gaining importance in the treatment of inorganic and resistant organic pollutants in wastewaters. In this study, electrocoagulation (EC) was applied to remove organic pollutants and oil and grease from canola oil wastewater using aluminum (Al) and iron (Fe) electrodes. The application of EC in the wastewater achieved more than 80% removal of organic carbon and nearly 100% removal of suspended solids (SS). The effectiveness of EC is influenced mainly by current density, pH, electrolyte (NaCl), electrode contact time and electrode type. It was observed that Al electrode combination yielded better removal at a lesser time compared to that of Fe electrodes. However, varying current densities had its significance in terms of coagulation time only. Increase in current density achieved decrease in coagulation time. Both Al and Fe could remove between 52-59% of oil and grease from canola oil wastewater
Automated inspection of turbine blades: Challenges and opportunities
NASA Technical Reports Server (NTRS)
Mehta, Manish; Marron, Joseph C.; Sampson, Robert E.; Peace, George M.
1994-01-01
Current inspection methods for complex shapes and contours exemplified by aircraft engine turbine blades are expensive, time-consuming and labor intensive. The logistics support of new manufacturing paradigms such as integrated product-process development (IPPD) for current and future engine technology development necessitates high speed, automated inspection of forged and cast jet engine blades, combined with a capability of retaining and retrieving metrology data for process improvements upstream (designer-level) and downstream (end-user facilities) at commercial and military installations. The paper presents the opportunities emerging from a feasibility study conducted using 3-D holographic laser radar in blade inspection. Requisite developments in computing technologies for systems integration of blade inspection in production are also discussed.
Suyemoto, M M; Barnes, H J; Borst, L B
2017-03-01
Pathogenic strains of Enterococcus cecorum (EC) expressing multidrug resistance have emerged. In National Antimicrobial Resistance Monitoring System (NARMS) data, EC is rarely recovered from chickens. Two NARMS methodologies (FDA and USDA) were compared with standard culture (SC) techniques for recovery of EC. NARMS methods failed to detect EC in 58 caecal samples, 20 chicken breast or six whole broiler samples. EC was recovered from 1 of 38 (2·6%) and 2 of 38 (5·2%) preharvest spinal lesions (USDA and FDA method, respectively). In contrast, using the SC method, EC was recovered from 44 of 53 (83%) caecal samples, all 38 (100%) spinal lesions, 14 of 20 (70%) chicken breast samples, and all three spinal lesions identified in whole carcasses. Compared with other Enterococcus spp., EC isolates had a higher prevalence of resistance to macrolides. The NARMS methods significantly affected recovery of enterococcal species other than EC. When the postharvest FDA method was applied to preharvest caecal samples, isolates of Enterococcus faecium were preferentially recovered. All 11 E. faecium isolates were multidrug resistant, including resistance to penicillin, daptomycin and linezolid. These findings confirm that current methodologies may not accurately identify the amount and range of antimicrobial resistance of enterococci from chicken sources. Enterococci are an important reservoir for antimicrobial resistance. This study demonstrates how current culture methods underreport resistance to macrolides in enterococci by selecting against strains of Enterococcus cecorum in pre- and postharvest chicken. Further, the application of postharvest surveillance methods to preharvest samples resulted in selective recovery of Enterococcus faecium over Enterococcus faecalis. Isolates of E. faecium recovered exhibited multidrug resistance including penicillin, daptomycin and linezolid resistance. These findings suggest that culture methodology significantly impacts the range and amount of antimicrobial resistance detected in enterococci isolated from chicken. © 2016 The Society for Applied Microbiology.
Curvers, W L; Singh, R; Song, L-M Wong-Kee; Wolfsen, H C; Ragunath, K; Wang, K; Wallace, M B; Fockens, P; Bergman, J J G H M
2008-02-01
To investigate the diagnostic potential of endoscopic tri-modal imaging and the relative contribution of each imaging modality (i.e. high-resolution endoscopy (HRE), autofluorescence imaging (AFI) and narrow-band imaging (NBI)) for the detection of early neoplasia in Barrett's oesophagus. Prospective multi-centre study. Tertiary referral centres. 84 Patients with Barrett's oesophagus. The Barrett's oesophagus was inspected with HRE followed by AFI. All lesions detected with HRE and/or AFI were subsequently inspected in detail by NBI for the presence of abnormal mucosal and/or microvascular patterns. Biopsies were obtained from all suspicious lesions for blinded histopathological assessment followed by random biopsies. (1) Number of patients with early neoplasia diagnosed by HRE and AFI; (2) number of lesions with early neoplasia detected with HRE and AFI; and (3) reduction of false positive AFI findings after NBI. Per patient analysis: AFI identified all 16 patients with early neoplasia identified with HRE and detected an additional 11 patients with early neoplasia that were not identified with HRE. In three patients no abnormalities were seen but random biopsies revealed HGIN. After HRE inspection, AFI detected an additional 102 lesions; 19 contained HGIN/EC (false positive rate of AFI after HRE: 81%). Detailed inspection with NBI reduced this false positive rate to 26%. In this international multi-centre study, the addition of AFI to HRE increased the detection of both the number of patients and the number of lesions with early neoplasia in patients with Barrett's oesophagus. The false positive rate of AFI was reduced after detailed inspection with NBI.
A systematic analysis of online marketing materials used by providers of expanded carrier screening.
Chokoshvili, Davit; Borry, Pascal; Vears, Danya F
2017-12-14
PurposeExpanded carrier screening (ECS) for a large number of recessive disorders is available to prospective parents through commercial providers. This study aimed to analyze the content of marketing materials on ECS providers' websites.MethodsTo identify providers of ECS tests, we undertook a comprehensive online search, reviewed recent academic literature on commercial carrier screening, and consulted with colleagues familiar with the current ECS landscape. The identified websites were archived in April 2017, and inductive content analysis was performed on website text, brochures and educational materials, and video transcripts.ResultsWe identified 18 ECS providers, including 16 commercial genetic testing companies. Providers typically described ECS as an important family planning tool. The content differed in both the tone used to promote ECS and the accuracy and completeness of the test information provided. We found that most providers offered complimentary genetic counseling to their consumers, although this was often optional, limited to the posttest context, and, in some cases, appeared to be available only to test-positive individuals.ConclusionThe quality of ECS providers' websites could be improved by offering more complete and accurate information about ECS and their tests. Providers should also ensure that all carrier couples receive posttest genetic counseling to inform their subsequent reproductive decision making.Genet Med advance online publication, 14 December 2017; doi:10.1038/gim.2017.222.
Removal of metals in leachate from sewage sludge using electrochemical technology.
Meunier, N; Drogui, P; Gourvenec, C; Mercier, G; Hausler, R; Blais, J F
2004-02-01
Heavy metals in acidic leachates from sewage sludge are usually removed by chemical precipitation, which often requires high concentration of chemicals and induces high metallic sludge production. Electrochemical technique has been explored as an alternative method in a laboratory pilot scale reactor for heavy metals (Cu and Zn) removal from sludge leachate. Three electrolytic cell arrangements using different electrodes materials were tested: mild steel or aluminium bipolar electrode (EC cell), Graphite/stainless steel monopolar electrodes (ER cell) and iron-monopolar electrodes (EC-ER cell). Results showed that the best performances of metal removal were obtained with EC and EC-ER cells using mild steel electrodes operated respectively at current intensities of 0.8 and 2.0 A through 30 and 60 min of treatment. The yields of Cu and Zn removal from leachate varied respectively from 92.4 to 98.9% and from 69.8 to 76.6%. The amounts of 55 and 44 kg tds(-1) of metallic sludge were respectively produced using EC and EC-ER cells. EC and EC-ER systems involved respectively a total cost of 21.2 and 13.1 CAN dollars per ton of dry sludge treated including only energy consumption and metallic sludge disposal. The treatment using EC-ER system was found to be effective and more economical than the traditional metal precipitation using either Ca(OH)2 and/or NaOH.
Gray, Michael J; Mhawech-Fauceglia, Paulette; Yoo, Eunjeong; Yang, Wangrong; Wu, Eijean; Lee, Amy S; Lin, Yvonne G
2013-07-01
Overexpression of the unfolded protein response master regulator GRP78 is associated with poor prognosis and therapeutic resistance in numerous human cancers, yet its role in endometrial cancers (EC) is undefined. To better understand the contribution of GRP78 to EC, we examined its expression levels in EC patient samples and EC cell lines. We demonstrate that GRP78 overexpression occurs more frequently in EC tissues compared with that found in normal endometrium, and that GRP78 expression occurs in most EC cell lines examined. Functional analysis demonstrated that GRP78 is inducible by cisplatin in EC cells, and siRNA knockdown of GRP78 augments chemotherapy-mediated cell death. Examination of AKT and GRP78 expression demonstrated that inhibition of AKT activity by MK2206 blocks GRP78 expression in EC cells. SiRNA studies also revealed that knockdown of GRP78 reduces but does not abrogate AKT activity, demonstrating that GRP78 is required for optimal AKT activity. In the presence of MK2206, siRNA knockdown of GRP78 does not augment AKT mediated survival in response to cisplatin treatment, suggesting that GRP78's antiapoptosis functions are part of the AKT survival pathway. Targeted therapies that reduce GRP78 expression or activity in cancers may serve to increase the effectiveness of current therapies for EC patients. Copyright © 2012 UICC.
Emergency Contraception in Mexico: Trends in Knowledge and Ever-Use 2006-2014.
Han, Leo; Saavedra-Avendano, Biani; Lambert, William; Fu, Rongwei; Rodriguez, Maria I; Edelman, Alison; Darney, Blair
2017-11-01
Objectives A package of interventions to introduce emergency contraception (EC) to Mexico was implemented, resulting in the addition of EC to the national family planning guidelines in 2004. We describe EC knowledge and use among women in Mexico over time. Methods We used the 2006, 2009, and 2014 of waves of a nationally representative demographic survey (ENADID). We assessed EC knowledge and usage in women ages 15-29 who are not using permanent methods and tested whether EC knowledge and use is changing over time after controlling for socio-demographic characteristics using logistic regression. Results Our sample included n = 99,223 (population N = 40,234,355) women ages 15-29. Overall, knowledge of EC increased over time: 62% in 2006 to 79% in 2009 to 83% in 2014 (p < 0.001). Among young women who have used contraception (n = 42,883; N = 16,816,701), the proportion that reported EC use increased from 3 to 11% to 29% (p < 0.001). Compared to non-users, women who had ever used EC were more likely to be using no method of contraception (44 vs. 35%) or barrier method (22 vs. 17%). Demographic factors including lower wealth, lower education, indigenous status and rural living are significantly associated with less EC knowledge and use. Stratified multivariate analysis found that demographic disadvantages magnify lower EC use among rural residents compared to non-rural residents. Conclusions for Practice Knowledge and use of EC are growing rapidly in Mexico, but disparities persist in demographically disadvantaged women, particularly those living in rural areas. Women who use EC appear to be at higher risk of unintended pregnancy based on current contraceptive use.
The Business of Childcare in Europe
ERIC Educational Resources Information Center
Penn, Helen
2014-01-01
This article is based on work undertaken for the European Commission (EC) as part of a wider project on what is termed "social services of general interest". The EC is currently engaged in considering what kind of legislative and quality assurance mechanisms might be promoted for those social services, which have been opened up to…
On the Intentional Control of Conditioned Evaluative Responses
ERIC Educational Resources Information Center
Balas, Robert; Gawronski, Bertram
2012-01-01
The evaluative conditioning (EC) effect is defined as a change in the evaluation of a conditioned stimulus (CS) due to its pairing with a valenced unconditioned stimulus (US). The current research investigated the controllability of EC effects by asking participants to either promote or prevent the influence of CS-US pairings before they provided…
Detection of Anomalous Machining Damages in Inconel 718 and TI 6-4 by Eddy Current Techniques
NASA Astrophysics Data System (ADS)
Lo, C. C. H.; Shimon, M.; Nakagawa, N.
2010-02-01
This paper reports on an eddy current (EC) study aimed at detecting anomalous machining damages in Inconel 718 and Ti 6-4 samples, including (i) surface discontinuities such as re-depositing of chips onto the machined surface, and (ii) microstructural damages manifested as a white surface layer and a subsurface layer of distorted grains, typically tens of microns thick. A series of pristine and machine-damaged coupons were studied by EC scans using a differential probe operated at 2 MHz to detect discontinuous surface anomalies, and by swept high frequency EC (SHFEC) measurements from 0.5 MHz to 65.5 MHz using proprietary detection coils to detect surface microstructural damages. In general, the EC c-scan data from machine-damaged surfaces show spatial variations with larger standard deviations than those from the undamaged surfaces. In some cases, the c-scan images exhibit characteristic bipolar indications in good spatial correlation with surface anomalies revealed by optical microscopy and laser profilometry. Results of the SHFEC measurements indicate a reduced near-surface conductivity of the damaged surfaces compared to the undamaged surfaces.
EDITORIAL: ECRH physics and technology in ITER
NASA Astrophysics Data System (ADS)
Luce, T. C.
2008-05-01
It is a great pleasure to introduce you to this special issue containing papers from the 4th IAEA Technical Meeting on ECRH Physics and Technology in ITER, which was held 6-8 June 2007 at the IAEA Headquarters in Vienna, Austria. The meeting was attended by more than 40 ECRH experts representing 13 countries and the IAEA. Presentations given at the meeting were placed into five separate categories EC wave physics: current understanding and extrapolation to ITER Application of EC waves to confinement and stability studies, including active control techniques for ITER Transmission systems/launchers: state of the art and ITER relevant techniques Gyrotron development towards ITER needs System integration and optimisation for ITER. It is notable that the participants took seriously the focal point of ITER, rather than simply contributing presentations on general EC physics and technology. The application of EC waves to ITER presents new challenges not faced in the current generation of experiments from both the physics and technology viewpoints. High electron temperatures and the nuclear environment have a significant impact on the application of EC waves. The needs of ITER have also strongly motivated source and launcher development. Finally, the demonstrated ability for precision control of instabilities or non-inductive current drive in addition to bulk heating to fusion burn has secured a key role for EC wave systems in ITER. All of the participants were encouraged to submit their contributions to this special issue, subject to the normal publication and technical merit standards of Nuclear Fusion. Almost half of the participants chose to do so; many of the others had been published in other publications and therefore could not be included in this special issue. The papers included here are a representative sample of the meeting. The International Advisory Committee also asked the three summary speakers from the meeting to supply brief written summaries (O. Sauter: EC wave physics and applications, M. Thumm: Source and transmission line development, and S. Cirant: ITER specific system designs). These summaries are included in this issue to give a more complete view of the technical meeting. Finally, it is appropriate to mention the future of this meeting series. With the ratification of the ITER agreement and the formation of the ITER International Organization, it was recognized that meetings conducted by outside agencies with an exclusive focus on ITER would be somewhat unusual. However, the participants at this meeting felt that the gathering of international experts with diverse specialities within EC wave physics and technology to focus on using EC waves in future fusion devices like ITER was extremely valuable. It was therefore recommended that this series of meetings continue, but with the broader focus on the application of EC waves to steady-state and burning plasma experiments including demonstration power plants. As the papers in this special issue show, the EC community is already taking seriously the challenges of applying EC waves to fusion devices with high neutron fluence and continuous operation at high reliability.
2012-10-08
differentiation of co- cultured cells in vivo and in vitro. We first utilized a co- culture of fluorescently labeled endothelial cells (ECs) and muscle...of 10T1/2 cells as pericytes (PCs) to the culture of MPCs and ECs can result in the stabilization of bioengineered vessels [10]. In the current study...Burlingame, CA). 2.2. Cell culture 2.2.1. MPC, EC, PC isolation and culture Green fluorescent protein (GFP)-labeled muscle progenitor cells (GFPþ MPCs
Development of Inspection Robots for Bridge Cables
Kim, Se-Hoon; Lee, Jong-Jae
2013-01-01
This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented. PMID:24459453
Device Rotates Bearing Balls For Inspection
NASA Technical Reports Server (NTRS)
Burley, R. K.
1988-01-01
Entire surface of ball inspected automatically and quickly. Device holds and rotates bearing ball for inspection by optical or mechanical surface-quality probe, eddy-current probe for detection of surface or subsurface defects, or circumference-measuring tool. Ensures entire surface of ball moves past inspection head quickly. New device saves time and increases reliability of inspections of spherical surfaces. Simple to operate and provides quick and easy access for loading and unloading of balls during inspection.
Michie, L; Cameron, S T; Glasier, A; Larke, N; Muir, A; Lorimer, A
2014-10-01
In Scotland most women get emergency contraception (EC) from pharmacies. Pharmacists currently cannot provide effective ongoing contraception after EC. In this pilot study, we aimed to determine the feasibility of a larger study designed to ascertain if pharmacy-based interventions can increase the uptake of effective contraception after EC. This is a pilot study of women presenting for levonorgestrel EC to community pharmacies in Edinburgh, UK, in 2012. Pharmacies were cluster randomized to provide either standard care or one of two interventions: (a) one packet of progestogen-only pills (POPs), giving women 1 month to arrange ongoing contraception; (b) invitation to present the empty EC packet to a family planning clinic (FPC) for contraceptive advice (rapid access). One hundred sixty-eight women were recruited from 11 pharmacies to POP (n=56), rapid access (n=58) and standard care (N=54) groups, respectively. Telephone follow-up was conducted successfully in 102 women (61%) 6-8 weeks later to determine current contraceptive use. In the POP arm, 35/39 (90%) women used the pills provided, and 9/28 women (32%) in the rapid access arm attended the FPC. The proportion of women using effective contraception at follow-up was significantly greater in both POP [56% (22/39), p=<0.001] and rapid access [52% (13/25), p=0.006] groups compared to standard care [16% (5/31)]. The relative probability of a woman using an effective method of contraception versus barrier/no method, after use of EC, was 3.13 [95% confidence interval (CI), 1.90-5.13] in the POP group and 2.57 (95% CI, 1.55-4.27) in the rapid access group. This promising pilot study suggests that simple pharmacy-based interventions may increase the uptake of effective contraception after EC. A larger study is required to provide further validation of these findings. For women obtaining EC from a pharmacy, simple interventions such as supplying 1 month of a POP, or offering rapid access to a FPC, hold promise as strategies to increase the uptake of effective contraception after EC. Copyright © 2014 Elsevier Inc. All rights reserved.
Molognoni, Luciano; de Sá Ploêncio, Leandro Antunes; Valese, Andressa Camargo; De Dea Lindner, Juliano; Daguer, Heitor
2016-01-15
In this work, a simplified extraction and short time of analysis method for the simultaneous determination of natamycin, nisin and sorbic acid in cheeses and cream by reverse phase liquid chromatography-electrospray-tandem mass spectrometry was developed. Full validation was performed according to the Commission Decision 2002/657/EC criteria and method applicability was checked on several samples, aiming to inspect their compliance with regulatory limits. The method was linear in the concentration ranges of 0-10mg kg(-1) (natamycin), 0-25mg kg(-1) (nisin) and 0 20mg kg(-1) (sorbic acid). Samples of the three most consumed types of cheese (fresh, pasta filata and ripened) in Brazil and cream (ultra high temperature and pasteurized, 20-30% fat content) were assessed. A surprising rate of non-compliance was observed, especially among ripened grated cheeses, since 80% of samples were above the maximum limit for sorbic acid with an average concentration of 2766.3±10.8mg kg(-1). Moreover, a major non-compliance for the cream samples was observed. The proposed method can be applied as an efficient tool for the inspection of preservatives in cheeses and cream. Copyright © 2015 Elsevier B.V. All rights reserved.
Interferometer for Space Station Windows
NASA Technical Reports Server (NTRS)
Hall, Gregory
2003-01-01
Inspection of space station windows for micrometeorite damage would be a difficult task insitu using current inspection techniques. Commercially available optical profilometers and inspection systems are relatively large, about the size of a desktop computer tower, and require a stable platform to inspect the test object. Also, many devices currently available are designed for a laboratory or controlled environments requiring external computer control. This paper presents an approach using a highly developed optical interferometer to inspect the windows from inside the space station itself using a self- contained hand held device. The interferometer would be capable as a minimum of detecting damage as small as one ten thousands of an inch in diameter and depth while interrogating a relatively large area. The current developmental state of this device is still in the proof of concept stage. The background section of this paper will discuss the current state of the art of profilometers as well as the desired configuration of the self-contained, hand held device. Then, a discussion of the developments and findings that will allow the configuration change with suggested approaches appearing in the proof of concept section.
NonDestructive Evaluation for Industrial & Development Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, James F.
2016-10-12
Provide overview of weld inspection for Non-Destructive Testing at LANL. This includes radiography (RT/DR/CR/CT for x-ray & neutron sources), ultrasonic testing (UT/PAUT), dye penetrant inspection (PT), eddy current inspection (ET) and magnetic particle testing (MT). Facilities and capabilities for weld inspection will be summarized with examples.
78 FR 28152 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... series airplanes. The existing AD currently requires repetitive inspections of the 80VU rack lower lateral fittings for damage; repetitive inspections of the 80VU rack lower central support for cracking... fittings of the 80VU rack. This proposed AD would reduce the inspection compliance time, add an inspection...
78 FR 60807 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... frequency eddy current (HFEC) inspection of the bear strap; External detailed and HFEC inspections of the... 737-53A1329, dated June 4, 2013, specifies contacting the manufacturer for inspection instructions... an internal detailed inspection of the skin assembly and bear strap, an internal high frequency eddy...
Eddy current technique for predicting burst pressure
Petri, Mark C.; Kupperman, David S.; Morman, James A.; Reifman, Jaques; Wei, Thomas Y. C.
2003-01-01
A signal processing technique which correlates eddy current inspection data from a tube having a critical tubing defect with a range of predicted burst pressures for the tube is provided. The method can directly correlate the raw eddy current inspection data representing the critical tubing defect with the range of burst pressures using a regression technique, preferably an artificial neural network. Alternatively, the technique deconvolves the raw eddy current inspection data into a set of undistorted signals, each of which represents a separate defect of the tube. The undistorted defect signal which represents the critical tubing defect is related to a range of burst pressures utilizing a regression technique.
46 CFR 195.11-25 - Loading and stowage.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (a) Vans required to be inspected and bearing a current inspection stamp may be accepted for loading... to his inspection to determine that electrical and pressure connections are in good condition and...
Motion-induced eddy current thermography for high-speed inspection
NASA Astrophysics Data System (ADS)
Wu, Jianbo; Li, Kongjing; Tian, Guiyun; Zhu, Junzhen; Gao, Yunlai; Tang, Chaoqing; Chen, Xiaotian
2017-08-01
This letter proposes a novel motion-induced eddy current based thermography (MIECT) for high-speed inspection. In contrast to conventional eddy current thermography (ECT) based on a time-varying magnetic field created by an AC coil, the motion-induced eddy current is induced by the relative motion between magnetic field and inspected objects. A rotating magnetic field created by three-phase windings is used to investigate the heating principle and feasibility of the proposed method. Firstly, based on Faraday's law the distribution of MIEC is investigated, which is then validated by numerical simulation. Further, experimental studies are conducted to validate the proposed method by creating rotating magnetic fields at different speeds from 600 rpm to 6000 rpm, and it is verified that rotating speed will increase MIEC intensity and thereafter improve the heating efficiency. The conclusion can be preliminarily drawn that the proposed MIECT is a platform suitable for high-speed inspection.
2017-01-01
In the field of evaluative conditioning (EC), two opposing theories—propositional single-process theory versus dual-process theory—are currently being discussed in the literature. The present set of experiments test a crucial prediction to adjudicate between these two theories: Dual-process theory postulates that evaluative conditioning can occur without awareness of the contingency between conditioned stimulus (CS) and unconditioned stimulus (US); in contrast, single-process propositional theory postulates that EC requires CS-US contingency awareness. In a set of three studies, we experimentally manipulate contingency awareness by presenting the CSs very briefly, thereby rendering it unlikely to be processed consciously. We address potential issues with previous studies on EC with subliminal or near-threshold CSs that limited their interpretation. Across two experiments, we consistently found an EC effect for CSs presented for 1000 ms and consistently failed to find an EC effect for briefly presented CSs. In a third pre-registered experiment, we again found evidence for an EC effect with CSs presented for 1000 ms, and we found some indication for an EC effect for CSs presented for 20 ms. PMID:28989730
Heycke, Tobias; Aust, Frederik; Stahl, Christoph
2017-09-01
In the field of evaluative conditioning (EC), two opposing theories-propositional single-process theory versus dual-process theory-are currently being discussed in the literature. The present set of experiments test a crucial prediction to adjudicate between these two theories: Dual-process theory postulates that evaluative conditioning can occur without awareness of the contingency between conditioned stimulus (CS) and unconditioned stimulus (US); in contrast, single-process propositional theory postulates that EC requires CS-US contingency awareness. In a set of three studies, we experimentally manipulate contingency awareness by presenting the CSs very briefly, thereby rendering it unlikely to be processed consciously. We address potential issues with previous studies on EC with subliminal or near-threshold CSs that limited their interpretation. Across two experiments, we consistently found an EC effect for CSs presented for 1000 ms and consistently failed to find an EC effect for briefly presented CSs. In a third pre-registered experiment, we again found evidence for an EC effect with CSs presented for 1000 ms, and we found some indication for an EC effect for CSs presented for 20 ms.
Expression of Finger Millet EcDehydrin7 in Transgenic Tobacco Confers Tolerance to Drought Stress.
Singh, Rajiv Kumar; Singh, Vivek Kumar; Raghavendrarao, Sanagala; Phanindra, Mullapudi Lakshmi Venkata; Venkat Raman, K; Solanke, Amolkumar U; Kumar, Polumetla Ananda; Sharma, Tilak Raj
2015-09-01
One of the critical alarming constraints for agriculture is water scarcity. In the current scenario, global warming due to climate change and unpredictable rainfall, drought is going to be a master player and possess a big threat to stagnating gene pool of staple food crops. So it is necessary to understand the mechanisms that enable the plants to cope with drought stress. In this study, effort was made to prospect the role of EcDehydrin7 protein from normalized cDNA library of drought tolerance finger millet in transgenic tobacco. Biochemical and molecular analyses of T0 transgenic plants were done for stress tolerance. Leaf disc assay, seed germination test, dehydration assay, and chlorophyll estimation showed EcDehydrin7 protein directly link to drought tolerance. Northern and qRT PCR analyses shows relatively high expression of EcDehydrin7 protein compare to wild type. T0 transgenic lines EcDehydrin7(11) and EcDehydrin7(15) shows superior expression among all lines under study. In summary, all results suggest that EcDehydrin7 protein has a remarkable role in drought tolerance and may be used for sustainable crop breeding program in other food crops.
NASA Technical Reports Server (NTRS)
Phelps, M. L.
1979-01-01
A survey was conducted to determine current in-service inspection practices for all types of aircraft structure and particularly for advanced composite structures. The survey consisted of written questionnaires to commercial airlines, visits to airlines, aircraft manufacturers, and government agencies, and a literature search. Details of the survey including visits, questions asked, a bibliography of reviewed literature and details of the results are reported. From the results, a current in-service inspection baseline and a preliminary inspection program for advanced composite structures is documented as appendices to the report.
Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K
2011-12-01
Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.
Ramsden, Nicola L; Buetow, Lori; Dawson, Alice; Kemp, Lauris A; Ulaganathan, Venkatsubramanian; Brenk, Ruth; Klebe, Gerhard; Hunter, William N
2009-04-23
The nonmevalonate route to isoprenoid biosynthesis is essential in Gram-negative bacteria and apicomplexan parasites. The enzymes of this pathway are absent from mammals, contributing to their appeal as chemotherapeutic targets. One enzyme, 2C-methyl-d-erythritol-2,4-cyclodiphosphate synthase (IspF), has been validated as a target by genetic approaches in bacteria. Virtual screening against Escherichia coli IspF (EcIspF) was performed by combining a hierarchical filtering methodology with molecular docking. Docked compounds were inspected and 10 selected for experimental validation. A surface plasmon resonance assay was developed and two weak ligands identified. Crystal structures of EcIspF complexes were determined to support rational ligand development. Cytosine analogues and Zn(2+)-binding moieties were characterized. One of the putative Zn(2+)-binding compounds gave the lowest measured K(D) to date (1.92 +/- 0.18 muM). These data provide a framework for the development of IspF inhibitors to generate lead compounds of therapeutic potential against microbial pathogens.
78 FR 21576 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... with Inspection Condition 5: Repeat the high frequency eddy current or magnetic particle inspection to... latch pins for discrepancies; and an HFEC or magnetic particle inspection of cam latch 1 and cam latch 2...
76 FR 63172 - Airworthiness Directives; The Boeing Company Model 767 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... repetitive detailed and high frequency eddy current (HFEC) inspections of the station (STA) 1809.5 bulkhead... detailed and high frequency eddy current (HFEC) inspections for cracking as specified in Parts 1, 2, 3, and... rule to provide the applicable, current SRMs; we have re-identified subsequent tables accordingly. We...
77 FR 37332 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... the high frequency eddy current inspection for cracking of the critical fastener holes, and repair if... of the bulkhead, and repair if necessary; and proposed an option to the high frequency eddy current...-15152 (72 FR 44753, August 9, 2007)), do a high frequency eddy current (HFEC) inspection for cracking of...
77 FR 43178 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... eddy current high frequency (ETHF) inspections for cracking on the aft side of the left and right wing... NPRM proposed to require repetitive eddy current high frequency (ETHF) inspections for cracking on the...,000 flight cycles after the effective date of this AD, whichever occurs later, do an eddy current high...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-16
... (FC). For the reasons described above, this AD requires initial and repetitive eddy current... requires initial and repetitive eddy current inspections, and depending on findings, accomplishment of... (landings) on the MLG after the effective date of this AD, whichever occurs later, eddy current inspect all...
77 FR 4407 - Modernization of Poultry Slaughter Inspection
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-27
...The Food Safety and Inspection Service (FSIS) is proposing a new inspection system for young chicken and turkey slaughter establishments that would replace the current Streamlined Inspection System (SIS), the New Line Speed Inspection System (NELS), and the New Turkey Inspection System (NTIS). The Agency is also proposing several changes that would affect all establishments that slaughter poultry other than ratites, regardless of the inspection system under which they operate. This proposed rule is a result of the Agency's 2011 regulatory review efforts conducted under Executive Order 13563 on Improving Regulation and Regulatory Review.
Navigation Lock and Dam Inspection and Emergency Repairs Workshop Summary
2006-09-01
Inspection and Emergency Repairs Workshop Summary John E. Hite, Jr., James E. Clausner, and Dinah N. McComas, editors Coastal and Hydraulics Laboratory...Engineer Research and Development Center (ERDC) Coastal and Hydraulics Laboratory hosted a “Navigation Lock and Dam Inspection and Emergency Repairs...applications ..............................................................................12 Current inspection policies for hydraulic steel structures
Bourke, Liam; Bauld, Linda; Bullen, Christopher; Cumberbatch, Marcus; Giovannucci, Edward; Islami, Farhad; McRobbie, Hayden; Silverman, Debra T; Catto, James W F
2017-06-01
Use of electronic cigarettes (ECs) is on the rise in most high-income countries. Smoking conventional cigarettes is a known risk factor for urologic malignancy incidence, progression, and mortality, as well as for other urologic health indicators. The potential impact of EC use on urologic health is therefore of clinical interest to the urology community. To review the available data on current EC use, including potential benefits in urologic patients, potential issues linked to toxicology of EC constituents, and how this might translate into urologic health risks. A Medline search was carried out in August 2016 for studies reporting urologic health outcomes and EC use. Snowballing techniques were also used to identify relevant studies from recent systematic reviews. A narrative synthesis of data around EC health outcomes, toxicology, and potential use in smoking cessation and health policy was carried out. We found no studies to date that have been specifically designed to prospectively assess urologic health risks, even in an observational setting. Generating such data would be an important contribution to the debate on the role of ECs in public health and clinical practice. There is evidence from a recent Cochrane review of RCTs that ECs can support smoking cessation. There are emerging data indicating that potentially harmful components of ECs such as tobacco-specific nitrosamines, polyaromatic hydrocarbons, and heavy metals could be linked to possible urologic health risks. ECs might be a useful tool to encourage cessation of conventional cigarette smoking. However, data collection around the specific impact of ECs on urologic health is needed to clarify the possible patient benefits, outcomes, and adverse events. While electronic cigarettes might help some people to stop smoking, their overall impact on urologic health is not clear. Copyright © 2017 European Association of Urology. All rights reserved.
Nozadi, Sara S; Spinrad, Tracy L; Johnson, Scott P; Eisenberg, Nancy
2018-06-01
The current study examined whether an important temperamental characteristic, effortful control (EC), moderates the associations between dispositional anger and sadness, attention biases, and social functioning in a group of preschool-aged children (N = 77). Preschoolers' attentional biases toward angry and sad facial expressions were assessed using eye-tracking, and we obtained teachers' reports of children's temperament and social functioning. Associations of dispositional anger and sadness with time looking at relevant negative emotional stimuli were moderated by children's EC, but relations between time looking at emotional faces and indicators of social functioning, for the most part, were direct and not moderated by EC. In particular, time looking at angry faces (and low EC) predicted high levels of aggressive behaviors, whereas longer time looking at sad faces (and high EC) predicted higher social competence. Finally, latency to detect angry faces predicted aggressive behavior under conditions of average and low levels of EC. Findings are discussed in terms of the importance of differentiating between components of attention biases toward distinct negative emotions, and implications for attention training. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Soft drink wastewater treatment by electrocoagulation-electrooxidation processes.
Linares Hernández, Ivonne; Barrera Díaz, Carlos; Valdés Cerecero, Mario; Almazán Sánchez, Perla Tatiana; Castañeda Juárez, Monserrat; Lugo Lugo, Violeta
2017-02-01
The aim of this work was to implement a coupled system, a monopolar Electrocoagulation (EC)-Electrooxidation (EO) processes, for the treatment of soft drink wastewater. For the EC test, Cu-Cu, anode-cathode were used at current densities of 17, 51 and 68 mA cm -2 . Only 37.67% of chemical oxygen demand (COD) and 27% of total organic carbon (TOC) were removed at 20 min with an optimum pH of 8, this low efficiency can be associated with the high concentration of inorganic ions which inhibit the oxidation of organic matter due to their complexation with copper ions. Later EO treatment was performed with boron-doped diamond-Cu electrodes and a current density of 30 Am -2 . The coupled EC-EO system was efficient to reduce organic pollutants from initial values of 1875 mg L -1 TOC and 4300 mg L -1 COD, the removal efficiencies were 75% and 85%, respectively. Electric energy consumption to degrade a kilogram of a pollutant in the soft drink wastewater using EC was 3.19 kWh kg -1 TOC and 6.66 kWh kg -1 COD. It was concluded that the coupled system EC-EO was effective for the soft drink wastewater treatment, reducing operating costs and residence time, and allowing its reuse in indirect contact with humans, thus contributing to the sustainable reuse as an effluent of industrial wastewater.
NASA Astrophysics Data System (ADS)
Andre, R.; Carlsson, J.; Gorelenkova, M.; Jardin, S.; Kaye, S.; Poli, F.; Yuan, X.
2016-10-01
TRANSP is an integrated interpretive and predictive transport analysis tool that incorporates state of the art heating/current drive sources and transport models. The treatments and transport solvers are becoming increasingly sophisticated and comprehensive. For instance, the ISOLVER component provides a free boundary equilibrium solution, while the PT- SOLVER transport solver is especially suited for stiff transport models such as TGLF. TRANSP incorporates high fidelity heating and current drive source models, such as NUBEAM for neutral beam injection, the beam tracing code TORBEAM for EC, TORIC for ICRF, the ray tracing TORAY and GENRAY for EC. The implementation of selected components makes efficient use of MPI for speed up of code calculations. Recently the GENRAY-CQL3D solver for modeling of LH heating and current drive has been implemented and currently being extended to multiple antennas, to allow modeling of EAST discharges. Also, GENRAY+CQL3D is being extended to the use of EC/EBW and of HHFW for NSTX-U. This poster will describe present uses of the code worldwide, as well as plans for upgrading the physics modules and code framework. Work supported by the US Department of Energy under DE-AC02-CH0911466.
Treatment of Ni-EDTA containing wastewater by electrocoagulation using iron scraps packed-bed anode.
Ye, Xiaokun; Zhang, Junya; Zhang, Yan; Lv, Yuancai; Dou, Rongni; Wen, Shulong; Li, Lianghao; Chen, Yuancai; Hu, YongYou
2016-12-01
The unique electrocoagulator proposed in this study is highly efficient at removing Ni-EDTA, providing a potential remediation option for wastewater containing lower concentrations of Ni-EDTA (Ni ≤ 10 mg L -1 ). In the electrocoagulation (EC) system, cylindrical graphite was used as a cathode, and a packed-bed formed from iron scraps was used as an anode. The results showed that the removal of Ni-EDTA increased with the application of current and favoured acidic conditions. We also found that the iron scrap packed-bed anode was superior in its treatment ability and specific energy consumption (SECS) compared with the iron rod anode. In addition, the packed density and temperature had a large influence on the energy consumption (ECS). Over 94.3% of Ni and 95.8% of TOC were removed when conducting the EC treatment at an applied current of 0.5 A, initial pH of 3, air-purged rate 0.2 L min -1 , anode packed density of 400 kg m -3 temperature of 313 K and time of 30 min. SEM analysis of the iron scraps indicated that the specific area of the anode increased after the EC. The XRD analysis of flocs produced during EC revealed that hematite (α-Fe 2 O 3 ) and magnetite (Fe 3 O 4 ) were the main by-products under aerobic and anoxic conditions, respectively. A kinetic study demonstrated that the removal of Ni-EDTA followed a first-order model with the current parameters. Moreover, the removal efficiency of real wastewater was essentially consistent with that of synthetic wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.
Solak, Murat; Kiliç, Mehmet; Hüseyin, Yazici; Sencan, Aziz
2009-12-15
In this study, removal of suspended solids (SS) and turbidity from marble processing wastewaters by electrocoagulation (EC) process were investigated by using aluminium (Al) and iron (Fe) electrodes which were run in serial and parallel connection systems. To remove these pollutants from the marble processing wastewater, an EC reactor including monopolar electrodes (Al/Fe) in parallel and serial connection system, was utilized. Optimization of differential operation parameters such as pH, current density, and electrolysis time on SS and turbidity removal were determined in this way. EC process with monopolar Al electrodes in parallel and serial connections carried out at the optimum conditions where the pH value was 9, current density was approximately 15 A/m(2), and electrolysis time was 2 min resulted in 100% SS removal. Removal efficiencies of EC process for SS with monopolar Fe electrodes in parallel and serial connection were found to be 99.86% and 99.94%, respectively. Optimum parameters for monopolar Fe electrodes in both of the connection types were found to be for pH value as 8, for electrolysis time as 2 min. The optimum current density value for Fe electrodes used in serial and parallel connections was also obtained at 10 and 20 A/m(2), respectively. Based on the results obtained, it was found that EC process running with each type of the electrodes and the connections was highly effective for the removal of SS and turbidity from marble processing wastewaters, and that operating costs with monopolar Al electrodes in parallel connection were the cheapest than that of the serial connection and all the configurations for Fe electrode.
Detecting nuclear materials smuggling: performance evaluation of container inspection policies.
Gaukler, Gary M; Li, Chenhua; Ding, Yu; Chirayath, Sunil S
2012-03-01
In recent years, the United States, along with many other countries, has significantly increased its detection and defense mechanisms against terrorist attacks. A potential attack with a nuclear weapon, using nuclear materials smuggled into the country, has been identified as a particularly grave threat. The system for detecting illicit nuclear materials that is currently in place at U.S. ports of entry relies heavily on passive radiation detectors and a risk-scoring approach using the automated targeting system (ATS). In this article we analyze this existing inspection system and demonstrate its performance for several smuggling scenarios. We provide evidence that the current inspection system is inherently incapable of reliably detecting sophisticated smuggling attempts that use small quantities of well-shielded nuclear material. To counter the weaknesses of the current ATS-based inspection system, we propose two new inspection systems: the hardness control system (HCS) and the hybrid inspection system (HYB). The HCS uses radiography information to classify incoming containers based on their cargo content into "hard" or "soft" containers, which then go through different inspection treatment. The HYB combines the radiography information with the intelligence information from the ATS. We compare and contrast the relative performance of these two new inspection systems with the existing ATS-based system. Our studies indicate that the HCS and HYB policies outperform the ATS-based policy for a wide range of realistic smuggling scenarios. We also examine the impact of changes in adversary behavior on the new inspection systems and find that they effectively preclude strategic gaming behavior of the adversary. © 2011 Society for Risk Analysis.
NASA Technical Reports Server (NTRS)
Reinhart, Richard C.
1992-01-01
The Experiment Control and Monitor (EC&M) software was developed at NASA Lewis Research Center to support the Advanced Communications Technology Satellite (ACTS) High Burst Rate Link Evaluation Terminal (HBR-LET). The HBR-LET is an experimenter's terminal to communicate with the ACTS for various investigations by government agencies, universities, and industry. The EC&M software is one segment of the Control and Performance Monitoring (C&PM) software system of the HBR-LET. The EC&M software allows users to initialize, control, and monitor the instrumentation within the HBR-LET using a predefined sequence of commands. Besides instrument control, the C&PM software system is also responsible for computer communication between the HBR-LET and the ACTS NASA Ground Station and for uplink power control of the HBR-LET to demonstrate power augmentation during rain fade events. The EC&M Software User's Guide, Version 1.0 (NASA-CR-189160) outlines the commands required to install and operate the EC&M software. Input and output file descriptions, operator commands, and error recovery procedures are discussed in the document. The EC&M Software Maintenance Manual, Version 1.0 (NASA-CR-189161) is a programmer's guide that describes current implementation of the EC&M software from a technical perspective. An overview of the EC&M software, computer algorithms, format representation, and computer hardware configuration are included in the manual.
Structures and Evolutions of Explosive Cyclones over the Northwestern and Northeastern Pacific
NASA Astrophysics Data System (ADS)
Zhang, Shuqin; Fu, Gang
2018-06-01
In this study, the structures and evolutions of moderate (MO) explosive cyclones (ECs) over the Northwestern Pacific (NWP) and Northeastern Pacific (NEP) are investigated and compared using composite analysis with cyclone-relative coordinates. Final Operational Global Analysis data gathered during the cold seasons (October-April) of the 15 years from 2000 to 2015 are used. The results indicate that MO NWP ECs have strong baroclinicity and abundant latent heat release at low levels and strong upper-level forcing, which favors explosive cyclogenesis. The rapid development of MO NEP ECs results from their interaction with a northern cyclone and a large middle-level advection of cyclonic vorticity. The structural differences between MO NWP ECs and MO NEP ECs are significant. This results from their specific large-scale atmospheric and oceanic environments. MO NWP ECs usually develop rapidly in the east and southeast of the Japan Islands; the intrusion of cold dry air from the East Asian continent leads to strong baroclinicity, and the Kuroshio/Kuroshio Extension provides abundant latent heat release at low levels. The East Asian subtropical westerly jet stream supplies strong upper-level forcing. While MO NEP ECs mainly occur over the NEP, the low-level baroclinicity, upper-level jet stream, and warm ocean currents are relatively weaker. The merged cyclone associated with a strong middle-level trough transports large cyclonic vorticity to MO NEP ECs, which favors their rapid development.
Status of the ITER Electron Cyclotron Heating and Current Drive System
NASA Astrophysics Data System (ADS)
Darbos, Caroline; Albajar, Ferran; Bonicelli, Tullio; Carannante, Giuseppe; Cavinato, Mario; Cismondi, Fabio; Denisov, Grigory; Farina, Daniela; Gagliardi, Mario; Gandini, Franco; Gassmann, Thibault; Goodman, Timothy; Hanson, Gregory; Henderson, Mark A.; Kajiwara, Ken; McElhaney, Karen; Nousiainen, Risto; Oda, Yasuhisa; Omori, Toshimichi; Oustinov, Alexander; Parmar, Darshankumar; Popov, Vladimir L.; Purohit, Dharmesh; Rao, Shambhu Laxmikanth; Rasmussen, David; Rathod, Vipal; Ronden, Dennis M. S.; Saibene, Gabriella; Sakamoto, Keishi; Sartori, Filippo; Scherer, Theo; Singh, Narinder Pal; Strauß, Dirk; Takahashi, Koji
2016-01-01
The electron cyclotron (EC) heating and current drive (H&CD) system developed for the ITER is made of 12 sets of high-voltage power supplies feeding 24 gyrotrons connected through 24 transmission lines (TL), to five launchers, four located in upper ports and one at the equatorial level. Nearly all procurements are in-kind, following general ITER philosophy, and will come from Europe, India, Japan, Russia and the USA. The full system is designed to couple to the plasma 20 MW among the 24 MW generated power, at the frequency of 170 GHz, for various physics applications such as plasma start-up, central H&CD and magnetohydrodynamic (MHD) activity control. The design takes present day technology and extends toward high-power continuous operation, which represents a large step forward as compared to the present state of the art. The ITER EC system will be a stepping stone to future EC systems for DEMO and beyond.
Measurement of the depth of narrow slotted sections in eddy current reference standards
NASA Astrophysics Data System (ADS)
Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin
2007-02-01
The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.
Hannah, Rachael M; Dunn, Kathryn M; Bonev, Adrian D; Nelson, Mark T
2011-05-01
Calcium-sensitive potassium (K(Ca)) channels have been shown to modulate the diameter of cerebral pial arteries; however, little is known regarding their roles in controlling cerebral parenchymal arterioles (PAs). We explored the function and cellular distribution of small-conductance (SK(Ca)) and intermediate-conductance (IK(Ca)) K(Ca) channels and large-conductance K(Ca) (BK(Ca)) channels in endothelial cells (ECs) and smooth muscle cells (SMCs) of PAs. Both SK(Ca) and IK(Ca) channels conducted the outward current in isolated PA ECs (current densities, ~20 pA/pF and ~28 pA/pF at +40 mV, respectively), but these currents were not detected in PA SMCs. In contrast, BK(Ca) currents were prominent in PA SMCs (~154 pA/pF), but were undetectable in PA ECs. Pressurized PAs constricted to inhibition of SK(Ca) (~16%) and IK(Ca) (~16%) channels, but were only modestly affected by inhibition of BK(Ca) channels (~5%). Blockade of SK(Ca) and IK(Ca) channels decreased resting cortical cerebral blood flow (CBF) by ~15%. NS309 (6,7-dichloro-1H-indole-2,3-dione3-oxime), a SK(Ca)/IK(Ca) channel opener, hyperpolarized PA SMCs by ~27 mV, maximally dilated pressurized PAs, and increased CBF by ~40%. In conclusion, these data show that SK(Ca) and IK(Ca) channels in ECs profoundly modulate PA tone and CBF, whereas BK(Ca) channels in SMCs only modestly influence PA diameter.
Unmanned surface vessel (USV) systems for bridge inspection : final report.
DOT National Transportation Integrated Search
2016-08-01
The use of unmanned surface vehicles (USVs) for bridge inspection has been explored. The following issues were considered: (1) the requirements of and : current techniques utilized in on-water bridge inspection; (2) USV design and configuration consi...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-23
... frequency eddy current inspection for cracking of the keyway of the fuel tank access door cutout on the left... NPRM proposed to require doing a high frequency eddy current inspection for [[Page 35610
Contoured Surface Eddy Current Inspection System
Batzinger, Thomas James; Fulton, James Paul; Rose, Curtis Wayne; Perocchi, Lee Cranford
2003-04-08
Eddy current inspection of a contoured surface of a workpiece is performed by forming a backing piece of flexible, resiliently yieldable material with a contoured exterior surface conforming in shape to the workpiece contoured surface. The backing piece is preferably cast in place so as to conform to the workpiece contoured surface. A flexible eddy current array probe is attached to the contoured exterior surface of the backing piece such that the probe faces the contoured surface of the workpiece to be inspected when the backing piece is disposed adjacent to the workpiece. The backing piece is then expanded volumetrically by inserting at least one shim into a slot in the backing piece to provide sufficient contact pressure between the probe and the workpiece contoured surface to enable the inspection of the workpiece contoured surface to be performed.
NASA Astrophysics Data System (ADS)
Ide, S.; Takenaga, H.; Isayama, A.; Sakamoto, Y.; Yoshida, M.; Gormezano, C.
2007-11-01
Impact of the electron cyclotron range of frequency wave (ECRF) on the internal transport barriers (ITBs) in a weak shear (WS) plasma has been investigated in JT-60U. The fundamental O-mode ECRF of 110 GHz injected obliquely (co-current drive) from the low field side is used. It is observed that the ion temperature (Ti) ITB in a WS plasma can be degraded by ECRF. It is clarified for the first time that the degradation depends increasingly on the EC power (PEC) but decreasingly on the plasma current (Ip). Moreover it is confirmed that ECRF affects the toroidal rotation (Vt) indirectly and results in the flattening of Vt(ρ) and therefore the radial electric field (Er) profiles regardless of the direction of the target Vt(ρ), peaking co or counter direction (relative to the Ip direction). Furthermore, it is recently found that Ti and Vt in the whole ITB region are affected with almost no delay from the EC onset even with off-axis EC deposition. These results indicate that EC injection unveiled a semi-global structure that characterizes Ti ITB in a WS plasma.
Current advances in esophageal cancer proteomics.
Uemura, Norihisa; Kondo, Tadashi
2015-06-01
We review the current status of proteomics for esophageal cancer (EC) from a clinician's viewpoint. The ultimate goal of cancer proteomics is the improvement of clinical outcome. The proteome as a functional translation of the genome is a straightforward representation of genomic mechanisms that trigger carcinogenesis. Cancer proteomics has identified the mechanisms of carcinogenesis and tumor progression, detected biomarker candidates for early diagnosis, and provided novel therapeutic targets for personalized treatments. Our review focuses on three major topics in EC proteomics: diagnostics, treatment, and molecular mechanisms. We discuss the major histological differences between EC types, i.e., esophageal squamous cell carcinoma and adenocarcinoma, and evaluate the clinical significance of published proteomics studies, including promising diagnostic biomarkers and novel therapeutic targets, which should be further validated prior to launching clinical trials. Multi-disciplinary collaborations between basic scientists, clinicians, and pathologists should be established for inter-institutional validation. In conclusion, EC proteomics has provided significant results, which after thorough validation, should lead to the development of novel clinical tools and improvement of the clinical outcome for esophageal cancer patients. This article is part of a Special Issue entitled: Medical Proteomics. Copyright © 2014 Elsevier B.V. All rights reserved.
Chou, Wei-Lung; Wang, Chih-Ta; Chang, Wen-Chun; Chang, Shih-Yu
2010-08-15
In this study, metal hydroxides generated during electrocoagulation (EC) were used to remove the chemical oxygen demand (COD) of oxide chemical mechanical polishing (oxide-CMP) wastewater from a semiconductor manufacturing plant by EC. Adsorption studies were conducted in a batch system for various current densities and temperatures. The COD concentration in the oxide-CMP wastewater was effectively removed and decreased by more than 90%, resulting in a final wastewater COD concentration that was below the Taiwan discharge standard (100 mg L(-1)). Since the processed wastewater quality exceeded the direct discharge standard, the effluent could be considered for reuse. The adsorption kinetic studies showed that the EC process was best described using the pseudo-second-order kinetic model at the various current densities and temperatures. The experimental data were also tested against different adsorption isotherm models to describe the EC process. The Freundlich adsorption isotherm model predictions matched satisfactorily with the experimental observations. Thermodynamic parameters, including the Gibbs free energy, enthalpy, and entropy, indicated that the COD adsorption of oxide-CMP wastewater on metal hydroxides was feasible, spontaneous and endothermic in the temperature range of 288-318 K. Copyright 2010 Elsevier B.V. All rights reserved.
Removal of nitrate and sulphate from biologically treated municipal wastewater by electrocoagulation
NASA Astrophysics Data System (ADS)
Sharma, Arun Kumar; Chopra, A. K.
2017-06-01
The present investigation observed the effect of current density ( j), electrocoagulation (EC) time, inter electrode distance, electrode area, initial pH and settling time on the removal of nitrate (NO3 -) and sulphate (SO4 2-) from biologically treated municipal wastewater (BTMW), and optimization of the operating conditions of the EC process. A glass chamber of two-liter volume was used for the experiments with DC power supply using two electrode plates of aluminum (Al-Al). The maximum removal of NO3 - (63.21 %) and SO4 2- (79.98 %) of BTMW was found with the optimum operating conditions: current density: 2.65 A/m2, EC time: 40 min, inter electrode distance: 0.5 cm, electrode area: 160 cm2, initial pH: 7.5 and settling time: 60 min. The EC brought down the concentration of NO3 - within desirable limit of the Bureau of Indian Standard (BIS)/WHO for drinking water. Under optimal operating conditions, the operating cost was found to be 1.01/m3 of water in terms of the electrode consumption (23.71 × 10-5 kg Al/m3) and energy consumption (101.76 kWh/m3).
An overview of carbon materials for flexible electrochemical capacitors.
He, Yongmin; Chen, Wanjun; Gao, Caitian; Zhou, Jinyuan; Li, Xiaodong; Xie, Erqing
2013-10-07
Under the background of the quick development of lightweight, flexible, and wearable electronic devices in our society, a flexible and highly efficient energy management strategy is needed for their counterpart energy-storage systems. Among them, flexible electrochemical capacitors (ECs) have been considered as one of the most promising candidates because of their significant advantages in power and energy densities, and unique properties of being flexible, lightweight, low-cost, and environmentally friendly compared with current energy storage devices. In a common EC, carbon materials play an irreplaceable and principal role in its energy-storage performance. Up till now, most progress towards flexible ECs technologies has mostly benefited from the continuous development of carbon materials. As a result, in view of the dual remarkable highlights of ECs and carbon materials, a summary of recent research progress on carbon-based flexible EC electrode materials is presented in this review, including carbon fiber (CF, consisting of carbon microfiber-CMF and carbon nanofiber-CNF) networks, carbon nanotube (CNT) and graphene coatings, CNT and/or graphene papers (or films), and freestanding three-dimensional (3D) flexible carbon-based macroscopic architectures. Furthermore, some promising carbon materials for great potential applications in flexible ECs are introduced. Finally, the trends and challenges in the development of carbon-based electrode materials for flexible ECs and their smart applications are analyzed.
Fabbri, Barbara; Bonoldi, Lucia; Guidi, Vincenzo; Cruciani, Giuseppe; Casotti, Davide; Malagù, Cesare; Bellussi, Giuseppe; Millini, Roberto; Montanari, Luciano; Carati, Angela; Rizzo, Caterina; Montanari, Erica; Zanardi, Stefano
2017-07-26
A deepened investigation on an innovative organic-inorganic hybrid material, referred to as ECS-14 (where ECS = Eni carbon silicates), revealed the possibility to use them as gas sensors. Indeed, among ECS phases, the crystalline state and the hexagonal microplateletlike morphology characteristic of ECS-14 seemed favorable properties to obtain continuous and uniform films. ECS-14 phase was used as functional material in screen-printable compositions and was thus deposited by drop coating for morphological, structural, thermal, and electrical characterizations. Possible operation at room temperature was investigated as technological progress, offering intrinsic safety in sensors working in harsh or industrial environments and avoiding high power consumption of most common sensors based on metal oxide semiconductors. Electrical characterization of the sensors based on ECS-14 versus concentrations of gaseous analytes gave significant results at room temperature in the presence of humidity, thereby demonstrating fundamental properties for a good quality sensor (speed, reversibility, and selectivity) that make them competitive with respect to systems currently in use. Remarkably, we observed functionality reversal of the organic and inorganic components; that is, in contrast to other hybrids, for ECS-14 the functional site has been ascribed to the inorganic phase while the organic component provided structural stability to the material. The sensing mechanism for humidity was also investigated.
Aoudj, S; Khelifa, A; Drouiche, N
2017-08-01
Semiconductor industry effluents contain organic and inorganic pollutants, such as sodium dodecyl sulfate (SDS), fluoride and ammonia, at high levels which consists a major environmental issue. A combined EC-EF process is proposed as a post-treatment after precipitation for simultaneous clarification and removal of pollutants. In EC step, a hybrid Fe-Al was used as the soluble anode in order to avoid supplementary EC step. EC-Fe is more suitable for SDS removal; EC-Al is more suitable for fluoride removal, while EC with hybrid Al-Fe makes a good compromise. Clarification and ammonia oxidation were achieved in the EF step. Effects of anodic material, initial pH, current, anion nature, chloride concentration and initial pollutant concentration were studied. The final concentrations may reach 0.27, 6.23 and 0.22 mg L -1 for SDS, fluoride and ammonia respectively. These concentrations are far lower than the correspondent discharge limits. Similarly, the final turbidity was found 4.35 NTU which is lower than 5NTU and the treated water does not need further filtration before discharge. Furthermore, the EC-EF process proves to be sufficiently energy-efficient with less soluble electrode consumption. Copyright © 2017 Elsevier Ltd. All rights reserved.
Prognostic Significance of POLE Proofreading Mutations in Endometrial Cancer
Church, David N.; Stelloo, Ellen; Nout, Remi A.; Valtcheva, Nadejda; Depreeuw, Jeroen; ter Haar, Natalja; Noske, Aurelia; Amant, Frederic; Wild, Peter J.; Lambrechts, Diether; Jürgenliemk-Schulz, Ina M.; Jobsen, Jan J.; Smit, Vincent T. H. B. M.; Creutzberg, Carien L.; Bosse, Tjalling
2015-01-01
Background: Current risk stratification in endometrial cancer (EC) results in frequent over- and underuse of adjuvant therapy, and may be improved by novel biomarkers. We examined whether POLE proofreading mutations, recently reported in about 7% of ECs, predict prognosis. Methods: We performed targeted POLE sequencing in ECs from the PORTEC-1 and -2 trials (n = 788), and analyzed clinical outcome according to POLE status. We combined these results with those from three additional series (n = 628) by meta-analysis to generate multivariable-adjusted, pooled hazard ratios (HRs) for recurrence-free survival (RFS) and cancer-specific survival (CSS) of POLE-mutant ECs. All statistical tests were two-sided. Results: POLE mutations were detected in 48 of 788 (6.1%) ECs from PORTEC-1 and-2 and were associated with high tumor grade (P < .001). Women with POLE-mutant ECs had fewer recurrences (6.2% vs 14.1%) and EC deaths (2.3% vs 9.7%), though, in the total PORTEC cohort, differences in RFS and CSS were not statistically significant (multivariable-adjusted HR = 0.43, 95% CI = 0.13 to 1.37, P = .15; HR = 0.19, 95% CI = 0.03 to 1.44, P = .11 respectively). However, of 109 grade 3 tumors, 0 of 15 POLE-mutant ECs recurred, compared with 29 of 94 (30.9%) POLE wild-type cancers; reflected in statistically significantly greater RFS (multivariable-adjusted HR = 0.11, 95% CI = 0.001 to 0.84, P = .03). In the additional series, there were no EC-related events in any of 33 POLE-mutant ECs, resulting in a multivariable-adjusted, pooled HR of 0.33 for RFS (95% CI = 0.12 to 0.91, P = .03) and 0.26 for CSS (95% CI = 0.06 to 1.08, P = .06). Conclusion: POLE proofreading mutations predict favorable EC prognosis, independently of other clinicopathological variables, with the greatest effect seen in high-grade tumors. This novel biomarker may help to reduce overtreatment in EC. PMID:25505230
Rothrauff-Laschober, Tanja C; Eby, Lillian Turner de Tormes; Sauer, Julia B
2013-01-01
When mental health counselors have limited and/or inadequate training in substance use disorders (SUDs), effective clinical supervision (ECS) may advance their professional development. The purpose of the current study was to investigate whether ECS is related to the job performance of SUD counselors. Data were obtained in person via paper-and-pencil surveys from 392 matched SUD counselor-clinical supervisor dyads working in 27 SUD treatment organizations across the United States. ECS was rated by counselors and measured with five multi-item scales (i.e., sponsoring counselors' careers, providing challenging assignments, role modeling, accepting/confirming counselors' competence, overall supervisor task proficiency). Clinical supervisors rated counselors' job performance, which was measured with two multi-item scales (i.e., task performance, performance within supervisory relationship). Using mixed-effects models, we found that most aspects of ECS are related to SUD counselor job performance. Thus, ECS may indeed enhance counselors' task performance and performance within the supervisory relationship, and, as a consequence, offset limited formal SUD training.
DOD Electronic Commerce (EC)/Electronic Data Interchange (EDI) in contracting report
NASA Astrophysics Data System (ADS)
1993-12-01
Use of Electronic Commerce (EC)/Electronic Data Interchange (EDI) to support Department of Defense (DoD) procurement processes has been under consideration for some time. A 1988 Deputy Secretary of Defense memo calls for maximum use of EDI, based on 10 years of DoD EDI investigation and experiments. In 1990, Defense Management Review Decision 941 stated, 'The strategic goal of DoD's current efforts is to provide the department with the capability to initiate, conduct, and maintain its external business related transactions and internal logistics, contracting, and financial activities without requiring the use of hard copy media.' The EC in Contracting PAT membership reflected a broad cross section of Military Services and Defense Agencies working on a full-time basis for 60 days. The diversity of the EC in Contracting PAT ensured that the needs and concerns of all DoD components were addressed during the creation of the report. The resultant plan, therefore, represents a comprehensive approach for implementing EC throughout the DoD.
Cerium oxide nanoparticles protect endothelial cells from apoptosis induced by oxidative stress.
Chen, Shizhu; Hou, Yingjian; Cheng, Gong; Zhang, Cuimiao; Wang, Shuxiang; Zhang, Jinchao
2013-07-01
Oxidative stress is well documented to cause injury to endothelial cells (ECs), which in turn trigger cardiovascular diseases. Previous studies revealed that cerium oxide nanoparticles (nanoceria) had antioxidant property, but the protective effect of nanoceria on ROS injury to ECs and cardiovascular diseases has not been reported. In the current study, we investigated the protective effect and underlying mechanisms of nanoceria on oxidative injury to ECs. The cell viability, lactate dehydrogenase release, cellular uptake, intracellular localization and reactive oxygen species (ROS) levels, endocytosis mechanism, cell apoptosis, and mitochondrial membrane potential were performed. The results indicated that nanoceria had no cytotoxicity on ECs but had the ability to prevent injury by H2O2. Nanoceria could be uptaken into ECs through caveolae- and clathrin-mediated endocytosis and distributed throughout the cytoplasma. The internalized nanoceria effectively attenuated ROS overproduction induced by H2O2. Apoptosis was also alleviated greatly by nanoceria pretreatment. These results may be helpful for more rational application of nanoceria in biomedical fields in the future.
2013-01-01
When mental health counselors have limited and/or inadequate training in substance use disorders (SUDs), effective clinical supervision (ECS) may advance their professional development. The purpose of the current study was to investigate whether ECS is related to the job performance of SUD counselors. Data were obtained in person via paper-and-pencil surveys from 392 matched SUD counselor-clinical supervisor dyads working in 27 SUD treatment organizations across the United States. ECS was rated by counselors and measured with five multi-item scales (i.e., sponsoring counselors’ careers, providing challenging assignments, role modeling, accepting/confirming counselors’ competence, overall supervisor task proficiency). Clinical supervisors rated counselors’ job performance, which was measured with two multi-item scales (i.e., task performance, performance within supervisory relationship). Using mixed-effects models, we found that most aspects of ECS are related to SUD counselor job performance. Thus, ECS may indeed enhance counselors’ task performance and performance within the supervisory relationship, and, as a consequence, offset limited formal SUD training. PMID:25061265
Camouflaging endothelial cells: does it prolong graft survival?
Stuhlmeier, K M; Lin, Y
1999-08-05
Camouflaging antigens on the surface of cells seems an appealing way to prevent activation of the immune system. We explored the possibility of preventing hyperacute rejection by chemically camouflaging endothelial cells (EC). In vitro as well as in vivo experiments were performed. First, the ability of mPEG coating to prevent antibody-antigen interactions was evaluated. Second, we tested the degree to which mPEG coating prevents activation of EC by stimuli such as TNF-alpha and LPS. Third, in vivo experiments were performed to test the ability of mPEG coating to prolong xenograft survival. We demonstrate that binding of several antibodies to EC or serum proteins can be inhibited by mPEG. Furthermore, binding of TNF-alpha as well as LPS to EC is blocked since mPEG treatment of EC inhibits the subsequent up-regulation of E-selectin by these stimuli. However, in vivo experiments revealed that currently this method alone is not sufficient to prevent hyperacute rejection.
Farsalinos, Konstantinos E; Voudris, Vassilis; Poulas, Konstantinos
2015-05-15
Studies have found that metals are emitted to the electronic cigarette (EC) aerosol. However, the potential health impact of exposure to such metals has not been adequately defined. The purpose of this study was to perform a risk assessment analysis, evaluating the exposure of electronic cigarette (EC) users to metal emissions based on findings from the published literature. Two studies were found in the literature, measuring metals emitted to the aerosol from 13 EC products. We estimated that users take on average 600 EC puffs per day, but we evaluated the daily exposure from 1200 puffs. Estimates of exposure were compared with the chronic Permissible Daily Exposure (PDE) from inhalational medications defined by the U.S. Pharmacopeia (cadmium, chromium, copper, lead and nickel), the Minimal Risk Level (MRL) defined by the Agency for Toxic Substances and Disease Registry (manganese) and the Recommended Exposure Limit (REL) defined by the National Institute of Occupational Safety and Health (aluminum, barium, iron, tin, titanium, zinc and zirconium). The average daily exposure from 13 EC products was 2.6 to 387 times lower than the safety cut-off point of PDEs, 325 times lower than the safety limit of MRL and 665 to 77,514 times lower than the safety cut-off point of RELs. Only one of the 13 products was found to result in exposure 10% higher than PDE for one metal (cadmium) at the extreme daily use of 1200 puffs. Significant differences in emissions between products were observed. Based on currently available data, overall exposure to metals from EC use is not expected to be of significant health concern for smokers switching to EC use, but is an unnecessary source of exposure for never-smokers. Metal analysis should be expanded to more products and exposure can be further reduced through improvements in product quality and appropriate choice of materials.
DOT National Transportation Integrated Search
2008-05-01
This Phase I report provides a comprehensive and in-depth review of the current status of in-line inspection technologies, including, but not limited to, Magnetic (Axial MFL, Circumferential MFL), Ultrasonic (UT), and Geometrical (Caliper) methods, i...
77 FR 39188 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-02
... existing AD currently requires repetitive inspections to detect discrepancies of the wiring and surrounding... new sleeves, for certain airplanes; and repair or replacement of the wiring and sleeves with new parts... currently requires repetitive inspections to detect discrepancies of the wiring and surrounding Teflon...
DOT National Transportation Integrated Search
2015-11-01
Most commercial vehicles on the road today use : low-voltage electrical systems (12/24 volts direct : current). The current Federal Motor Carrier Safety : Regulations (FMCSRs), North American Standard : (NAS) inspection procedures, and out-of-service...
Tension-activated channels in the mechanism of osmotic fitness in Pseudomonas aeruginosa
Rowe, Ian; Schams, Anthony; Mayhew, Christina
2017-01-01
Pseudomonas aeruginosa (PA) is an opportunistic pathogen with an exceptional ability to adapt to a range of environments. Part of its adaptive potential is the ability to survive drastic osmolarity changes. Upon a sudden dilution of external medium, such as during exposure to rain, bacteria evade mechanical rupture by engaging tension-activated channels that act as osmolyte release valves. In this study, we compare fast osmotic permeability responses in suspensions of wild-type PA and Escherichia coli (EC) strains in stopped-flow experiments and provide electrophysiological descriptions of osmotic-release channels in PA. Using osmotic dilution experiments, we first show that PA tolerates a broader range of shocks than EC. We record the kinetics of cell equilibration reported by light scattering responses to osmotic up- and down-shocks. PA exhibits a lower water permeability and faster osmolyte release rates during large osmotic dilutions than EC, which correlates with better survival. To directly characterize the PA tension-activated channels, we generate giant spheroplasts from this microorganism and record current responses in excised patches. Unlike EC, which relies primarily on two types of channels, EcMscS and EcMscL, to generate a distinctive two-wave pressure ramp response, PA exhibits a more gradual response that is dominated by MscL-type channels. Genome analysis, cloning, and expression reveal that PA possesses one MscL-type (PaMscL) and two MscS-type (PaMscS-1 and 2) proteins. In EC spheroplasts, both PaMscS channels exhibit a slightly earlier activation by pressure compared with EcMscS. Unitary currents reveal that PaMscS-2 has a smaller conductance, higher anionic preference, stronger inactivation, and slower recovery compared with PaMscS-1. We conclude that PA relies on MscL as the major valve defining a high rate of osmolyte release sufficient to curb osmotic swelling under extreme shocks, but it still requires MscS-type channels with a strong propensity to inactivation to properly terminate massive permeability response. PMID:28424229
Mass spectrometric methods for monitoring redox processes in electrochemical cells.
Oberacher, Herbert; Pitterl, Florian; Erb, Robert; Plattner, Sabine
2015-01-01
Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation-reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common. © 2013 The Authors. Mass Spectrometry Reviews published by Wiley Periodicals, Inc.
Pava, Matthew J.; Woodward, John J.
2012-01-01
Over the past fifty years a significant body of evidence has been compiled suggesting an interaction between the endocannabinoid (EC) system and alcohol dependence. However, much of this work has been conducted only in the past two decades following the elucidation of the molecular constituents of the EC system that began with the serendipitous discovery of the cannabinoid 1 receptor (CB1). Since then, novel pharmacological and genetic tools have enabled researchers to manipulate select components of the EC system, to determine their contribution to the motivation to consume ethanol. From these preclinical studies, it is evident that CB1 contributes the motivational and reinforcing properties of ethanol, and chronic consumption of ethanol alters EC transmitter levels and CB1 expression in brain nuclei associated with addiction pathways. These results are augmented by in vitro and ex vivo studies showing that acute and chronic treatment with ethanol produces physiologically relevant alterations in the function of the EC system. This report provides a current and comprehensive review of the literature regarding the interactions between ethanol and the EC system. We begin be reviewing the studies published prior to the discovery of the EC system that compared the behavioral and physiological effects of cannabinoids with ethanol in addition to cross-tolerance between these drugs. Next, a brief overview of the molecular constituents of the EC system is provided as context for the subsequent review of more recent studies examining the interaction of ethanol with the EC system. These results are compiled into a summary providing a scheme for the known changes to the components of the EC system in different stages of alcohol dependence. Finally, future directions for research are discussed. PMID:22459871
Mass spectrometric methods for monitoring redox processes in electrochemical cells
Oberacher, Herbert; Pitterl, Florian; Erb, Robert; Plattner, Sabine
2015-01-01
Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation–reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common. PMID:24338642
Effect of streptavidin-biotin on endothelial vasoregulation and leukocyte adhesion.
Chan, Bernard P; Reichert, William M; Truskey, George A
2004-08-01
The current study examines whether the adhesion promoting arginine-glycine-aspartate-streptavidin mutant (RGD-SA) also affects two important endothelial cell (EC) functions in vitro: vasoregulation and leukocyte adhesion. EC adherent to surfaces via fibronectin (Fn) or Fn plus RGD-SA were subjected to laminar shear flow and media samples were collected over a period of 4h to measure the concentration of nitric oxide (NO), prostacyclin (PGI(2)), and endothelin-1 (ET-1). Western blot analysis was used to quantify the levels of endothelial-derived nitric oxide synthase (eNOS) and cyclooxygenase II (COX II). In a separate set of experiments, fluorescent polymorphonuclear leukocyte (PMN) adhesion to EC was quantified for EC with and without exposure to flow preconditioning. When cell adhesion was supplemented with the SA-biotin system, flow-induced production of NO and PGI(2) increased significantly relative to cells adherent on Fn alone. Previous exposure of EC to shear flow also significantly decreased PMN attachment to SA-biotin supplemented EC, but only after 2h of exposure to shear flow. The observed decrease in PMN-EC adhesion was negated by NG-nitro-L-arginine methyl ester (L-NAME), an antagonist of NO synthesis, but not by indomethacin, an inhibitor to PGI(2) synthesis, indicating the induced effect of PMN-EC interaction is primarily NO-dependent. Results from this study suggest that the use of SA-biotin to supplement EC adhesion encourages vasodilation and PMN adhesion in vitro under physiological shear-stress conditions. We postulate that the presence of SA-biotin more efficiently transmits the shear-stress signal and amplifies the downstream events including the NO and PGI(2) release and leukocyte-EC inhibition. These results may have ramifications for reducing thrombus-induced vascular graft failure.
Demonstration of sawtooth period control with EC waves in KSTAR plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, J. H.; Bae, Y. S.; Joung, M.
2015-03-12
The sawtooth period control in tokamak is important issue in recent years because the sawtooth crash can trigger TM/NTM instabilities and drive plasmas unstable. The control of sawtooth period by the modification of local current profile near the q=1 surface using ECCD has been demonstrated in a number of tokamaks [1, 2] including KSTAR. As a result, developing techniques to control the sawtooth period as a way of controlling the onset of NTM has been an important area of research in recent years [3]. In 2012 KSTAR plasma campaign, the sawtooth period control is carried out by the different depositionmore » position of EC waves across the q=1 surface. The sawtooth period is shortened by on-axis co-ECCD (destabilization), and the stabilization of the sawtooth is also observed by off-axis co-ECCD at outside q=1 surface. In 2013 KSTAR plasma campaign, the sawtooth locking experiment with periodic forcing of 170 GHz EC wave is carried out to control the sawtooth period. The optimal target position which lengthens the sawtooth period is investigated by performing a scan of EC beam deposition position nearby q=1 surface at the toroidal magnetic field of 2.9 T and plasma current of 0.7 MA. The sawtooth locking by the modulated EC beam is successfully demonstrated as in [3-5] with the scan of modulation-frequency and duty-ratio at the low beta (β N~0.5) plasma. In this paper, the sawteeth behavior by the location of EC beam and the preliminary result of the sawtooth locking experiments in KSTAR will be presented.« less
75 FR 5692 - Airworthiness Directives; The Boeing Company Model 747-200C and -200F Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-04
... all Model 747-200C and -200F series airplanes. This AD requires a high frequency eddy current (HFEC... on July 6, 2009 (74 FR 31894). That NPRM proposed to require a high frequency eddy current inspection..., whichever occurs later: Do an open-hole high frequency eddy current (HFEC) inspection of all the fastener...
Determining confounding sensitivities in eddy current thin film measurements
NASA Astrophysics Data System (ADS)
Gros, Ethan; Udpa, Lalita; Smith, James A.; Wachs, Katelyn
2017-02-01
Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done by using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It was the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy-current testing was performed using a commercially available, hand-held eddy-current probe (ETA3.3H spring-loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe was sent to a hand-held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring-loaded eddy probe was at measuring film thickness under varying experimental conditions. This research studied the effects of a number of factors such as i) conductivity, ii) edge effect, iii) surface finish of base material and iv) cable condition.
Note: Eddy current displacement sensors independent of target conductivity.
Wang, Hongbo; Li, Wei; Feng, Zhihua
2015-01-01
Eddy current sensors (ECSs) are widely used for non-contact displacement measurement. In this note, the quantitative error of an ECS caused by target conductivity was analyzed using a complex image method. The response curves (L-x) of the ECS with different targets were similar and could be overlapped by shifting the curves on x direction with √2δ/2. Both finite element analysis and experiments match well with the theoretical analysis, which indicates that the measured error of high precision ECSs caused by target conductivity can be completely eliminated, and the ECSs can measure different materials precisely without calibration.
Petrie, Bruce; Barden, Ruth; Kasprzyk-Hordern, Barbara
2015-04-01
This review identifies understudied areas of emerging contaminant (EC) research in wastewaters and the environment, and recommends direction for future monitoring. Non-regulated trace organic ECs including pharmaceuticals, illicit drugs and personal care products are focused on due to ongoing policy initiatives and the expectant broadening of environmental legislation. These ECs are ubiquitous in the aquatic environment, mainly derived from the discharge of municipal wastewater effluents. Their presence is of concern due to the possible ecological impact (e.g., endocrine disruption) to biota within the environment. To better understand their fate in wastewaters and in the environment, a standardised approach to sampling is needed. This ensures representative data is attained and facilitates a better understanding of spatial and temporal trends of EC occurrence. During wastewater treatment, there is a lack of suspended particulate matter analysis due to further preparation requirements and a lack of good analytical approaches. This results in the under-reporting of several ECs entering wastewater treatment works (WwTWs) and the aquatic environment. Also, sludge can act as a concentrating medium for some chemicals during wastewater treatment. The majority of treated sludge is applied directly to agricultural land without analysis for ECs. As a result there is a paucity of information on the fate of ECs in soils and consequently, there has been no driver to investigate the toxicity to exposed terrestrial organisms. Therefore a more holistic approach to environmental monitoring is required, such that the fate and impact of ECs in all exposed environmental compartments are studied. The traditional analytical approach of applying targeted screening with low resolution mass spectrometry (e.g., triple quadrupoles) results in numerous chemicals such as transformation products going undetected. These can exhibit similar toxicity to the parent EC, demonstrating the necessity of using an integrated analytical approach which compliments targeted and non-targeted screening with biological assays to measure ecological impact. With respect to current toxicity testing protocols, failure to consider the enantiomeric distribution of chiral compounds found in the environment, and the possible toxicological differences between enantiomers is concerning. Such information is essential for the development of more accurate environmental risk assessment. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Steam generator tube inspection in Japan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukui, Shigetaka
1997-02-01
Steam generator tube inspection was first carried out in 1971 at Mihama Unit-1 that is first PWR plant in Japan, when the plant was brought into the first annual inspection. At that time, inspection was made on sampling basis, and only bobbin coil probe was used. After experiencing various kinds of tube degradations, inspection method was changed from sampling to all number of tubes, and various kinds of probes were used to get higher detectability of flaw. At present, it is required that all the tubes shall be inspected in their full length at each annual inspection using standard bobbinmore » coil probe, and some special probes for certain plants that have susceptibility of occurrence of flaw. Sleeve repaired portion is included in this inspection. As a result of analyses of eddy current testing data, all indications that have been evaluated to be 20% wall thickness or deeper shall be repaired by either plugging or sleeving, where flaw morphology is to be a wastage or wear. Other types of flaw such as IGA/SCC are not allowed to be left inservice when those indications are detected. These inspections are performed according to inspection procedures that are approved by regulatory authority. Actual inspections are witnessed by the Japan Power engineering and inspection corporation (JAPEIC)`s inspectors during data acquisition and analysis, and they issue inspection report to authority for review and approval. It is achieved high safety performance of steam generator through this method of inspections, however. some tube leakage problems were experienced in the past. To prevent recurrence of such events, government is conducting development and verification test program for new eddy current testing technology.« less
7 CFR 29.9402 - Policy statement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... available to serve the flue-cured marketing areas are currently adequate to provide inspection service as... buyers, and the lack of inspection personnel is not a limiting factor to accelerated marketings or the...
Application of Remote-Field Eddy Current Testing to Inspection of Unpiggable Pipelines
DOT National Transportation Integrated Search
2003-07-02
Corrosion of buried pipelines can lead to catastrophic failure. Many pipelines are successfully inspected by magnetic flux leakage (MFL) pigs to detect corrosion. However, there is a subset of pipelines for which MFL is not feasible. To inspect those...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-09
...-0102; Federal Emergency Management Agency Housing Inspection Services Customer Satisfaction Survey... Emergency Management Agency Housing Inspection Services Customer Satisfaction Survey. SUMMARY: The Federal... Inspection Services Customer Satisfaction Survey. Type of Information Collection: Revision of a currently...
A management system for evaluating the Virginia periodic motor vehicle inspection program.
DOT National Transportation Integrated Search
1977-01-01
A system for management evaluation of Virginia's periodic motor vehicle inspection (PMVI) program was developed which is similar to that currently in use by the Virginia Department of State Police, except for changes in the sample size of inspection ...
Emerging nondestructive inspection methods for aging aircraft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beattie, A; Dahlke, L; Gieske, J
This report identifies and describes emerging nondestructive inspection (NDI) methods that can potentially be used to inspect commercial transport and commuter aircraft for structural damage. The nine categories of emerging NDI techniques are: acoustic emission, x-ray computed tomography, backscatter radiation, reverse geometry x-ray, advanced electromagnetics, including magnetooptic imaging and advanced eddy current techniques, coherent optics, advanced ultrasonics, advanced visual, and infrared thermography. The physical principles, generalized performance characteristics, and typical applications associated with each method are described. In addition, aircraft inspection applications are discussed along with the associated technical considerations. Finally, the status of each technique is presented, with amore » discussion on when it may be available for use in actual aircraft maintenance programs. It should be noted that this is a companion document to DOT/FAA/CT-91/5, Current Nondestructive Inspection Methods for Aging Aircraft.« less
Webster, P; Maddox-Hyttel, C; Nöckler, K; Malakauskas, A; van der Giessen, J; Pozio, E; Boireau, P; Kapel, C M O
2006-01-01
A new EU directive relating to meat inspection for Trichinella, expected to come into force in 2006, imposes important modifications to current legislation. Nevertheless, several issues need more attention. Optimisation of methods, especially concerning sensitivity and digestibility of the meat to be inspected, along with further simplification of the legislation with regard to the number of techniques accepted, is recommended to guarantee that all member states of the EU will be given tools to perform inspection of consumer meat at the same high level. Additionally, there is a need for guidelines and protocols regarding optimal proficiency testing procedures. This paper presents an overview of the current methods for Trichinella meat inspection and their implementation in the EU, listing advantages and disadvantages for each method, including some suggestions for specific points of improvement.
Calvo-Artavia, F F; Nielsen, L R; Alban, L
2013-03-01
Under the current EU meat inspection regulation, every single carcase from all bovines above 6 weeks of age has to be examined for bovine cysticercosis (BC). This is time-consuming, costly, and is of limited value in countries with low prevalence. The aim of this study was to develop a stochastic simulation model for analysis of tentative risk-based meat inspection systems for BC in Danish cattle with regard to system sensitivity (SSSe), specificity and potential monetary benefits compared to the current system, which has an estimated SSSe of 15%. The relevant risk factors used to construct three alternative scenario trees were identified from previous Danish risk factor studies (1) gender, (2) grazing and (3) access to risky water sources. Thus, females, animals that had been grazing or animals with access to risky water sources were considered high-risk and would be subjected to invasive inspection at meat inspection. All animals in the low-risk groups (i.e. males, non-grazing or no access to risky water sources, respectively) would be subjected to visual inspection only. It was assumed that half of the cattle were slaughtered in abattoirs that would be able to reorganise the work at the slaughterline, allowing them to do with one meat inspector less. All abattoirs would gain on the price of sold uncut beef from the masseter muscles from visually inspected cattle. Under these assumptions, using gender and grazing were preferable due to them having SSSe only slightly lower than the current system, and highest effectiveness ratios, but they had a lower net economic effect (NEE) than the scenario using risky water sources. Using gender to differentiate high and low-risk groups was judged preferable over grazing due to feasibility, because the information is readily available at the slaughter line. The exact total NEE for the cattle sector depends on how many and which of the abattoirs that would be able to reorganise the work at the slaughter line to save money on inspection of the head of carcases. Overall, the SSSe was low in all scenarios leading to undetected BC-positive cattle both in the current meat inspection and under the investigated risk-based meat inspection systems. Therefore, improving the sensitivity of the methods used for inspection of high-risk cattle would be beneficial. Copyright © 2012 Elsevier B.V. All rights reserved.
Ferrous and ferric ion generation during iron electrocoagulation.
Lakshmanan, Divagar; Clifford, Dennis A; Samanta, Gautam
2009-05-15
Our research on arsenate removal by iron electrocoagulation (EC) produced highly variable results, which appeared to be due to Fe2+ generation without subsequent oxidation to Fe3+. Because the environmental technology literature is contradictory with regard to the generation of ferric or ferrous ions during EC, the objective of this research was to establish the iron species generated during EC with iron anodes. Experimental results demonstrated that Fe2+, not Fe3+, was produced at the iron anode. Theoretical current efficiency was attained based on Fe2+ production with a clean iron rod, regardless of current, dissolved-oxygen (DO) level, or pH (6.5-8.5). The Fe2+ remaining after generation and mixing decreased with increasing pH and DO concentration due to rapid oxidation to Fe3+. At pH 8.5, Fe2+ was completely oxidized, which resulted in the desired Fe(OH)3(s)/ FeOOH(s), whereas, at pH 6.5 and 7.5, incomplete oxidation was observed, resulting in a mixture of soluble Fe2+ and insoluble Fe(OH)3(s)/FeOOH(s). When compared with Fe2+ chemical coagulation, a transient pH increase during EC led to faster Fe2+ oxidation. In summary, for EC in the pH 6.5-7.5 range and at low DO conditions, there is a likelihood of soluble Fe2+ species passing through a subsequentfiltration process resulting in secondary contamination and inefficient contaminant removals.
Rochfort, Keith D; Cummins, Philip M
2015-07-01
Zonula occludens-1 (ZO-1) is essential to the proper assembly of interendothelial junction complexes that control blood-brain barrier (BBB) integrity. The goal of the current paper was to improve our understanding of how proinflammatory cytokines modulate ZO-1 properties within the human BBB microvascular endothelium. In this respect, we investigated the effects of TNF-α and IL-6 on ZO-1 using human brain microvascular endothelial cells (HBMvECs). Following treatment of HBMvECs with either cytokine (0-100 ng/ml, 18 h), we observed significantly decreased ZO-1 expression and ZO-1:occludin co-association, in parallel with increased ZO-1 phosphorylation (pTyr and pThr). All effects were dose-dependent. Either cytokine also caused extensive cell-cell border delocalization of ZO-1 in parallel with elevated HBMvEC permeability. Furthermore, pre-treatment of HBMvECs with antioxidants (superoxide dismutase, catalase, apocynin, N-acetylcysteine), or employing targeted inhibition of NADPH oxidase activation (NSC23766, gp91/p47 siRNA), were all found to comparably attenuate the cytokine-dependent decrease in ZO-1 protein expression. In summary, we present an in vitro model of how different proinflammatory cytokines can dysregulate ZO-1 properties in HBMvECs. A causal role for NADPH oxidase activation and oxidant signalling is also confirmed. Our findings add mechanistic depth to current in vivo models of BBB injury manifesting ZO-1 dysregulation. Copyright © 2015 Elsevier Inc. All rights reserved.
Airborne ultrasonic inspection of hides and leather
USDA-ARS?s Scientific Manuscript database
Currently, hides and leather are visually inspected and ranked for quality, sale price and usable area. Visual inspection is not reliable for detecting defects, which are usually hidden inside the material. This manual assessment is non-uniform among operators, and often leads to disputes over fai...
Compliance with OSHA's respiratory protection standard in hospitals.
Krishnan, U; Janicak, C A
1999-01-01
This study examined the incidence of violations of occupational safety and health standards for respiratory protection in hospitals. Data from Occupational Safety and Health Administration inspections that occurred in hospitals and resulted in violations of the respiratory protection standards were examined. From July 1, 1990, to June 30, 1995, the complaint rates for hazards in the workplace significantly increased. During 1990-1991, tuberculosis hazard complaint inspections rates were approximately 5 complaints per 1000 complaint inspections conducted. During 1994-1995, tuberculosis hazard complaint inspections rates were approximately 76 complaints per 1000 complaint inspections conducted, representing an increase of over 15 times. During this same period, the percentage of respiratory protection violations in relation to all violations doubled. Increased employee awareness of the hazards and current safety laws could have contributed to the increased frequency of employee complaints, leading to increases in inspections, violations, and fines. Employers must adhere to the current safety and health requirements specifically as they pertain to respiratory hazards and tuberculosis.
NASA Astrophysics Data System (ADS)
Chalmers, Alex
2004-09-01
To increase the security and throughput of ISO traffic through international terminals more technology must be applied to the problem. A transnational central archive of inspection records is discussed that can be accessed by national agencies as ISO containers approach their borders. The intent is to improve the throughput and security of the cargo inspection process. A review of currently available digital media archiving technologies is presented and their possible application to the tracking of international ISO container shipments. Specific image formats employed by current x-ray inspection systems are discussed. Sample x-ray data from systems in use today are shown that could be entered into such a system. Data from other inspection technologies are shown to be easily integrated, as well as the creation of database records suitable for interfacing with other computer systems. Overall system performance requirements are discussed in terms of security, response time and capacity. Suggestions for pilot projects based on existing border inspection processes are made also.
STS-114: Discovery Day 6 Post MMT Meeting
NASA Technical Reports Server (NTRS)
2005-01-01
Wayne Hale, Space Shuttle Deputy Program Manager and Steve Poulos, Orbiter Program Manager, discuss the damage assessment from the tiles that came off the Space Shuttle Discovery during launch. Poulos presents charts and discusses in detail the following topics: 1) Composite Tile Damage/Gap Filler Sites Evaluation; 2) Protruding Ceramic Shim Aft of the Nose Landing Gear Door (NLGD); 3) Protruding Chine Gap Filler; 4) RH NLGD Tile Damage; 5) RH NLGD Damage Analysis; 6) Left Wing Tile Damage; 7) Comparison of Ground Test Results vs. FD5 Focused Inspection; 8) Current Status: Focused Inspection 721L07-01 ITVC FD5 Image of Panel 7L Apex 9) Current Status: Focused Inspection Lower Panel 7L721L07-02; 10) Current Status Focused Inspection 721L10-02 Lower Panel 10L Close-up view; and 11) Window 1 Blanket. The presentation ends with a question and answer period from the news media.
Fahrenkrug, Eli; Maldonado, Stephen
2015-07-21
This Account describes a new electrochemical synthetic strategy for direct growth of crystalline covalent group IV and III-V semiconductor materials at or near ambient temperature conditions. This strategy, which we call "electrochemical liquid-liquid-solid" (ec-LLS) crystal growth, marries the semiconductor solvation properties of liquid metal melts with the utility and simplicity of conventional electrodeposition. A low-temperature liquid metal (i.e., Hg, Ga, or alloy thereof) acts simultaneously as the source of electrons for the heterogeneous reduction of oxidized semiconductor precursors dissolved in an electrolyte as well as the solvent for dissolution of the zero-valent semiconductor. Supersaturation of the semiconductor in the liquid metal triggers eventual crystal nucleation and growth. In this way, the liquid electrolyte-liquid metal-solid crystal phase boundary strongly influences crystal growth. As a synthetic strategy, ec-LLS has several intrinsic features that are attractive for preparing covalent semiconductor crystals. First, ec-LLS does not require high temperatures, toxic precursors, or high-energy-density semiconductor reagents. This largely simplifies equipment complexity and expense. In practice, ec-LLS can be performed with only a beaker filled with electrolyte and an electrical circuit capable of supplying a defined current (e.g., a battery in series with a resistor). By this same token, ec-LLS is compatible with thermally and chemically sensitive substrates (e.g., plastics) that cannot be used as deposition substrates in conventional syntheses of covalent semiconductors. Second, ec-LLS affords control over a host of crystal shapes and sizes through simple changes in common experimental parameters. As described in detail herein, large and small semiconductor crystals can be grown both homogeneously within a liquid metal electrode and heterogeneously at the interface of a liquid metal electrode and a seed substrate, depending on the particular details chosen for ec-LLS. Third, the rate of introduction of zero-valent materials into the liquid metal is precisely gated with a high degree of resolution by the applied potential/current. The intent of this Account is to summarize the key elements of ec-LLS identified to date, first contextualizing this method with respect to other semiconductor crystal growth methods and then highlighting some unique capabilities of ec-LLS. Specifically, we detail ec-LLS as a platform to prepare Ge and Si crystals from bulk- (∼1 cm(3)), micro- (∼10(-10) cm(3)), and nano-sized (∼10(-16) cm(3)) liquid metal electrodes in common solvents at low temperature. In addition, we describe our successes in the preparation of more compositionally complex binary covalent III-V semiconductors.
Autophagy orchestrates adaptive responses to targeted therapy in endometrial cancer.
Eritja, Núria; Chen, Bo-Juen; Rodríguez-Barrueco, Ruth; Santacana, Maria; Gatius, Sònia; Vidal, August; Martí, Maria Dolores; Ponce, Jordi; Bergadà, Laura; Yeramian, Andree; Encinas, Mario; Ribera, Joan; Reventós, Jaume; Boyd, Jeff; Villanueva, Alberto; Matias-Guiu, Xavier; Dolcet, Xavier; Llobet-Navàs, David
2017-03-04
Targeted therapies in endometrial cancer (EC) using kinase inhibitors rarely result in complete tumor remission and are frequently challenged by the appearance of refractory cell clones, eventually resulting in disease relapse. Dissecting adaptive mechanisms is of vital importance to circumvent clinical drug resistance and improve the efficacy of targeted agents in EC. Sorafenib is an FDA-approved multitarget tyrosine and serine/threonine kinase inhibitor currently used to treat hepatocellular carcinoma, advanced renal carcinoma and radioactive iodine-resistant thyroid carcinoma. Unfortunately, sorafenib showed very modest effects in a multi-institutional phase II trial in advanced uterine carcinoma patients. Here, by leveraging RNA-sequencing data from the Cancer Cell Line Encyclopedia and cell survival studies from compound-based high-throughput screenings we have identified the lysosomal pathway as a potential compartment involved in the resistance to sorafenib. By performing additional functional biology studies we have demonstrated that this resistance could be related to macroautophagy/autophagy. Specifically, our results indicate that sorafenib triggers a mechanistic MAPK/JNK-dependent early protective autophagic response in EC cells, providing an adaptive response to therapeutic stress. By generating in vivo subcutaneous EC cell line tumors, lung metastatic assays and primary EC orthoxenografts experiments, we demonstrate that targeting autophagy enhances sorafenib cytotoxicity and suppresses tumor growth and pulmonary metastasis progression. In conclusion, sorafenib induces the activation of a protective autophagic response in EC cells. These results provide insights into the unopposed resistance of advanced EC to sorafenib and highlight a new strategy for therapeutic intervention in recurrent EC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poli, Francesca M.; Fredrickson, Eric; Henderson, Mark A.
Time dependent simulations that evolve consistently the magnetic equilibrium and plasma pressure profiles and the width and frequency rotation of magnetic islands under the effect of the Electron Cyclotron feedback system are used to assess whether the control of NTMs on ITER is compatible with other simulataneous functionalities of the EC system, like core heating and current profile tailoring, or sawtooth control. Furthermore, results indicate that the power needs for control can be reduced if the EC power is reserved and if pre-emptive control is used as opposed to an active search for an already developed island.
Poli, Francesca M.; Fredrickson, Eric; Henderson, Mark A.; ...
2017-10-23
Time dependent simulations that evolve consistently the magnetic equilibrium and plasma pressure profiles and the width and frequency rotation of magnetic islands under the effect of the Electron Cyclotron feedback system are used to assess whether the control of NTMs on ITER is compatible with other simulataneous functionalities of the EC system, like core heating and current profile tailoring, or sawtooth control. Furthermore, results indicate that the power needs for control can be reduced if the EC power is reserved and if pre-emptive control is used as opposed to an active search for an already developed island.
14 CFR 91.417 - Maintenance records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... alteration and records of the 100-hour, annual, progressive, and other required or approved inspections, as... propeller, and each rotor. (ii) The current status of life-limited parts of each airframe, engine, propeller... are required to be overhauled on a specified time basis. (iv) The current inspection status of the...
14 CFR 91.417 - Maintenance records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... alteration and records of the 100-hour, annual, progressive, and other required or approved inspections, as... propeller, and each rotor. (ii) The current status of life-limited parts of each airframe, engine, propeller... are required to be overhauled on a specified time basis. (iv) The current inspection status of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-07
... the applicability and to require repetitive eddy current and visual inspections of the upper wing... the applicability and to require repetitive eddy current and visual inspections of the upper wing... Emergency AD 2007-0241-E to extend the applicability and to require repetitive eddy current and visual...
NASA Astrophysics Data System (ADS)
Malloy, Matt; Thiel, Brad; Bunday, Benjamin D.; Wurm, Stefan; Jindal, Vibhu; Mukhtar, Maseeh; Quoi, Kathy; Kemen, Thomas; Zeidler, Dirk; Eberle, Anna Lena; Garbowski, Tomasz; Dellemann, Gregor; Peters, Jan Hendrik
2015-09-01
The new device architectures and materials being introduced for sub-10nm manufacturing, combined with the complexity of multiple patterning and the need for improved hotspot detection strategies, have pushed current wafer inspection technologies to their limits. In parallel, gaps in mask inspection capability are growing as new generations of mask technologies are developed to support these sub-10nm wafer manufacturing requirements. In particular, the challenges associated with nanoimprint and extreme ultraviolet (EUV) mask inspection require new strategies that enable fast inspection at high sensitivity. The tradeoffs between sensitivity and throughput for optical and e-beam inspection are well understood. Optical inspection offers the highest throughput and is the current workhorse of the industry for both wafer and mask inspection. E-beam inspection offers the highest sensitivity but has historically lacked the throughput required for widespread adoption in the manufacturing environment. It is unlikely that continued incremental improvements to either technology will meet tomorrow's requirements, and therefore a new inspection technology approach is required; one that combines the high-throughput performance of optical with the high-sensitivity capabilities of e-beam inspection. To support the industry in meeting these challenges SUNY Poly SEMATECH has evaluated disruptive technologies that can meet the requirements for high volume manufacturing (HVM), for both the wafer fab [1] and the mask shop. Highspeed massively parallel e-beam defect inspection has been identified as the leading candidate for addressing the key gaps limiting today's patterned defect inspection techniques. As of late 2014 SUNY Poly SEMATECH completed a review, system analysis, and proof of concept evaluation of multiple e-beam technologies for defect inspection. A champion approach has been identified based on a multibeam technology from Carl Zeiss. This paper includes a discussion on the need for high-speed e-beam inspection and then provides initial imaging results from EUV masks and wafers from 61 and 91 beam demonstration systems. Progress towards high resolution and consistent intentional defect arrays (IDA) is also shown.
Turok, David K; Sanders, Jessica N; Thompson, Ivana S; Royer, Pamela A; Eggebroten, Jennifer; Gawron, Lori M
2016-06-01
We assessed intrauterine device (IUD) preference among women presenting for emergency contraception (EC) and the probability of pregnancy among concurrent oral levonorgestrel (LNG) plus LNG 52 mg IUD EC users. We offered women presenting for EC at a single family planning clinic the CuT380A IUD (copper IUD) or oral LNG 1.5 mg plus the LNG 52 mg IUD. Two weeks after IUD insertion, participants reported the results of a self-administered home urine pregnancy test. The primary outcome, EC failure, was defined as pregnancies resulting from intercourse occurring within five days prior to IUD insertion. One hundred eighty-eight women enrolled and provided information regarding their current menstrual cycle and recent unprotected intercourse. Sixty-seven (36%) chose the copper IUD and 121 (64%) chose oral LNG plus the LNG IUD. The probability of pregnancy two weeks after oral LNG plus LNG IUD EC use was 0.9% (95% CI 0.0-5.1%). The only positive pregnancy test after treatment occurred in a woman who received oral LNG plus the LNG IUD and who had reported multiple episodes of unprotected intercourse including an episode more than 5 days prior to treatment. Study participants seeking EC who desired an IUD preferentially chose oral LNG 1.5 mg with the LNG 52 mg IUD over the copper IUD. Neither group had EC treatment failures. Including the option of oral LNG 1.5 mg with concomitant insertion of the LNG 52 mg IUD in EC counseling may increase the number of EC users who opt to initiate highly effective reversible contraception. Consideration should be given to LNG IUD insertion with concomitant use of oral LNG 1.5 mg for EC. Use of this combination may increase the number of women initiating highly effective contraception at the time of their EC visit. Copyright © 2016 Elsevier Inc. All rights reserved.
Cholesterol-5,6-epoxides: chemistry, biochemistry, metabolic fate and cancer.
Poirot, Marc; Silvente-Poirot, Sandrine
2013-03-01
In the nineteen sixties it was proposed that cholesterol might be involved in the etiology of cancers and cholesterol oxidation products were suspected of being causative agents. Researchers had focused their attention on cholesterol-5,6-epoxides (5,6-ECs) based on several lines of evidence: 1) 5,6-ECs contained an oxirane group that was supposed to confer alkylating properties such as those observed for aliphatic and aromatic epoxides. 2) cholesterol-5,6-epoxide hydrolase (ChEH) was induced in pre-neoplastic lesions of skin from rats exposed to ultraviolet irradiations and ChEH was proposed to be involved in detoxification processes like other epoxide hydrolases. However, 5,6-ECs failed to induce carcinogenicity in rodents which ruled out a potent carcinogenic potential for 5,6-ECs. Meanwhile, clinical studies revealed an anomalous increase in the concentrations of 5,6β-EC in the nipple fluids of patients with pre-neoplastic breast lesions and in the blood of patients with endometrious cancers, suggesting that 5,6-ECs metabolism could be linked with cancer. Paradoxically, ChEH has been recently shown to be totally inhibited by therapeutic concentrations of tamoxifen (Tam), which is one of the main drugs used in the hormonotherapy and the chemoprevention of breast cancers. These data would suggest that the accumulation of 5,6-ECs could represent a risk factor, but we found that 5,6-ECs were involved in the induction of breast cancer cell differentiation and death induced by Tam suggesting a positive role of 5,6-ECs. These observations meant that the biochemistry and the metabolism of 5,6-ECs needed to be extensively studied. We will review the current knowledge and the future direction of 5,6-ECs chemistry, biochemistry, metabolism, and relationship with cancer. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Park, Minho; Na, Yong-Su; Seo, Jaemin; Kim, M.; Kim, Kyungjin
2018-01-01
We report the effect of the electron cyclotron (EC) beam width on the full suppression time of neoclassical tearing mode (NTM) using the finite difference method (FDM) based minimum seeking controller in ITER. An integrated numerical system is setup for time-dependent simulations of the NTM evolution in ITER by solving the modified Rutherford equation together with the plasma equilibrium, transport, and EC heating and current drive. The calculated magnetic island width and growth rate is converted to the Mirnov diagnostic signal as an input to the controller to mimic the real experiment. In addition, 10% of the noise is enforced to this diagnostic signal to evaluate the robustness of the controller. To test the dependency of the NTM stabilization time on the EC beam width, the EC beam width scan is performed for a perfectly aligned case first, then for cases with the feedback control using the minimum seeking controller. When the EC beam is perfectly aligned, the narrower the EC beam width, the smaller the NTM stabilization time is observed. As the beam width increases, the required EC power increases exponentially. On the other hand, when the minimum seeking controller is applied, NTM stabilization sometimes fails as the EC beam width decreases. This is consistently observed in the simulation with various representations of the noise as well as without the noise in the Mirnov signal. The higher relative misalignment, misalignment divided by the beam width, is found to be the reason for the failure with the narrower beam widths. The EC stabilization effect can be lower for the narrower beam widths than the broader ones even at the same misalignment due to the smaller ECCD at the island O-point. On the other hand, if the EC beam is too wide, the NTM stabilization time takes too long. Accordingly, the optimal EC beam width range is revealed to exist in the feedback stabilization of NTM.
Luo, Zhong-Cheng; Liu, Jian-Meng; Fraser, William D
2010-02-01
The adverse health effects of environmental contaminants (ECs) are a rising public health concern, and a major threat to sustainable socioeconomic development. The developing fetuses and growing children are particularly vulnerable to the adverse effects of ECs. However, assessing the health impact of ECs presents a major challenge, given that multiple outcomes may arise from one exposure, multiple exposures may result in one outcome, and the complex interactions between ECs, and between ECs, nutrients and genetic factors, and the dynamic temporal changes in EC exposures during the life course. Large-scale prospective birth cohort studies collecting extensive data and specimen starting from the prenatal or pre-conception period, although costly, hold promise as a means to more clearly quantify the health effects of ECs, and to unravel the complex interactions between ECs, nutrients and genotypes. A number of such large-scale studies have been launched in some developed counties. We present an overview of "why", "what" and "how" behind these efforts with an objective to uncover major unidentified limitations and needs. Three major limitations were identified: (1) limited data and bio-specimens regarding early life EC exposure assessments in some birth cohort studies; (2) heavy participant burdens in some birth cohort studies may bias participant recruitment, and risk substantial loss to follow-up, protocol deviations limiting the quality of data and specimens collection, with an overall potential bias towards the null effect; (3) lack of concerted efforts in building comparable birth cohorts across countries to take advantage of natural "experiments" (large EC exposure level differences between countries) for more in-depth assessments of dose-response relationships, threshold exposure levels, and positive and negative effect modifiers. Addressing these concerns in current or future large-scale birth cohort studies may help to produce better evidence on the health effects of ECs.
78 FR 8054 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-05
..., dated March 5, 1990) has not been done as of August 31, 2004 (the effective date of AD 2004-15-07... A310 series airplanes. The existing AD currently requires repetitive inspections for fatigue cracking... fatigue threshold and inspection interval resulted in a determination that reduced inspection thresholds...
USDA-ARS?s Scientific Manuscript database
Currently, blueberries are inspected and sorted by color, size and/or firmness (or softness) in packinghouses, using different inspection techniques like machine vision and mechanical vibration or impact. A new inspection technique is needed for effectively assessing both external features and inter...
Oceanic response to Typhoon Nari (2007) in the East China Sea
NASA Astrophysics Data System (ADS)
Oh, Kyung-Hee; Lee, Seok; Kang, Sok-Kuh; Song, Kyu-Min
2017-06-01
The oceanic response to a typhoon in the East China Sea (ECS) was examined using thermal and current structures obtained from ocean surface drifters and a bottom-moored current profiler installed on the right side of the typhoon's track. Typhoon Nari (2007) had strong winds as it passed the central region of the ECS. The thermal structure in the ECS responded to Typhoon Nari (2007) very quickly: the seasonal thermocline abruptly collapsed and the sea surface temperature dropped immediately by about 4°C after the typhoon passed. The strong vertical mixing and surface cooling caused by the typhoon resulted in a change in the thermal structure. Strong near-inertial oscillation occurred immediately after the typhoon passed and lasted for at least 4-5 days, during which a strong vertical current existed in the lower layer. Characteristics of the near-inertial internal oscillation were observed in the middle layer. The clockwise component of the inertial frequency was enhanced in the surface layer and at 63 m depth after the typhoon passed, with these layers almost perfectly out of phase. The vertical shear current was intensified by the interaction of the wind-driven current in the upper layer and the background semi-diurnal tidal current during the arrival of the typhoon, and also by the near-inertial internal oscillation after the typhoon passage. The strong near-inertial internal oscillation persisted without significant interfacial structure after the mixing of the thermocline, which could enhance the vertical mixing over several days.
Development of Modeling and Simulation for Magnetic Particle Inspection Using Finite Elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jun-Youl
2003-01-01
Magnetic particle inspection (MPI) is a widely used nondestructive inspection method for aerospace applications essentially limited to experiment-based approaches. The analysis of MPI characteristics that affect sensitivity and reliability contributes not only reductions in inspection design cost and time but also improvement of analysis of experimental data. Magnetic particles are easily attracted toward a high magnetic field gradient. Selection of a magnetic field source, which produces a magnetic field gradient large enough to detect a defect in a test sample or component, is an important factor in magnetic particle inspection. In this work a finite element method (FEM) has beenmore » employed for numerical calculation of the MPI simulation technique. The FEM method is known to be suitable for complicated geometries such as defects in samples. This thesis describes the research that is aimed at providing a quantitative scientific basis for magnetic particle inspection. A new FEM solver for MPI simulation has been developed in this research for not only nonlinear reversible permeability materials but also irreversible hysteresis materials that are described by the Jiles-Atherton model. The material is assumed to have isotropic ferromagnetic properties in this research (i.e., the magnetic properties of the material are identical in all directions in a single crystal). In the research, with a direct current field mode, an MPI situation has been simulated to measure the estimated volume of magnetic particles around defect sites before and after removing any external current fields. Currently, this new MPI simulation package is limited to solving problems with the single current source from either a solenoid or an axial directional current rod.« less
Distributed practice can boost evaluative conditioning by increasing memory for the stimulus pairs.
Richter, Jasmin; Gast, Anne
2017-09-01
When presenting a neutral stimulus (CS) in close temporal and spatial proximity to a positive or negative stimulus (US) the former is often observed to adopt the valence of the latter, a phenomenon named evaluative conditioning (EC). It is already well established that under most conditions, contingency awareness is important for an EC effect to occur. In addition to that, some findings suggest that awareness of the stimulus pairs is not only relevant during the learning phase, but that it is also relevant whether memory for the pairings is still available during the measurement phase. As previous research has shown that memory is better after temporally distributed than after contiguous (massed) repetitions, it seems plausible that also EC effects are moderated by distributed practice manipulations. This was tested in the current studies. In two experiments with successful distributed practice manipulations on memory, we show that also the magnitude of the EC effect was larger for pairs learned under spaced compared to massed conditions. Both effects, on memory and on EC, are found after a within-participant and after a between-participant manipulation. However, we did not find significant differences in the EC effect for different conditions of spaced practice. These findings are in line with the assumption that EC is based on similar processes as memory for the pairings. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kyung-Jin; Department of Biomedical Science, College of Medicine, Seoul National University, Seoul 110-799; Yun, Jang-Hyuk
Highlights: • PEDF was expressed and induced during the involuting phase of IH. • PEDF inhibited the cell growth of the involuting HemECs in an autocrine manner. • PEDF suppression restored the impaired cell growth of the involuting HemECs. - Abstract: Hemangioma is a benign tumor derived from abnormal blood vessel growth. Unlike other vascular tumor counterparts, a hemangioma is known to proliferate during its early stage but it is followed by a stage of involution where regression of the tumor occurs. The critical onset leading to the involution of hemangioma is currently not well understood. This study focused onmore » the molecular identities of the involution of hemangioma. We demonstrated that a soluble factor released from the involuting phase of hemangioma-derived endothelial cells (HemECs) and identified pigment epithelium-derived factor (PEDF) as an anti-angiogenic factor that was associated with the growth inhibition of the involuting HemECs. The growth inhibition of the involuting HemECs was reversed by suppression of PEDF in the involuting HemECs. Furthermore, we found that PEDF was more up-regulated in the involuting phase of hemangioma tissues than in the proliferating or the involuted. Taken together, we propose that PEDF accelerates the involution of hemangioma by growth inhibition of HemECs in an autocrine manner. The regulatory mechanism of PEDF expression could be a potential therapeutic target to treat hemangiomas.« less
Modulation of neuronal sodium channels by the sea anemone peptide BDS-I
Liu, Pin; Jo, Sooyeon
2012-01-01
Blood-depressing substance I (BDS-I), a 43 amino-acid peptide from sea anemone venom, is used as a specific inhibitor of Kv3-family potassium channels. We found that BDS-I acts with even higher potency to modulate specific types of voltage-dependent sodium channels. In rat dorsal root ganglion (DRG) neurons, 3 μM BDS-I strongly enhanced tetrodotoxin (TTX)-sensitive sodium current but weakly inhibited TTX-resistant sodium current. In rat superior cervical ganglion (SCG) neurons, which express only TTX-sensitive sodium current, BDS-I enhanced current elicited by small depolarizations and slowed decay of currents at all voltages (EC50 ∼ 300 nM). BDS-I acted with exceptionally high potency and efficacy on cloned human Nav1.7 channels, slowing inactivation by 6-fold, with an EC50 of approximately 3 nM. BDS-I also slowed inactivation of sodium currents in N1E-115 neuroblastoma cells (mainly from Nav1.3 channels), with an EC50 ∼ 600 nM. In hippocampal CA3 pyramidal neurons (mouse) and cerebellar Purkinje neurons (mouse and rat), BDS-I had only small effects on current decay (slowing inactivation by 20–50%), suggesting relatively weak sensitivity of Nav1.1 and Nav1.6 channels. The biggest effect of BDS-I in central neurons was to enhance resurgent current in Purkinje neurons, an effect reflected in enhancement of sodium current during the repolarization phase of Purkinje neuron action potentials. Overall, these results show that BDS-I acts to modulate sodium channel gating in a manner similar to previously known neurotoxin receptor site 3 anemone toxins but with different isoform sensitivity. Most notably, BDS-I acts with very high potency on human Nav1.7 channels. PMID:22442564
78 FR 73816 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-09
... it displays a currently valid OMB control number. Food Safety and Inspection Service Title... Safety and Inspection Service (FSIS) has been delegated the authority to exercise the functions of the Secretary as provided in the Federal Meat Inspection Act (FMIA) (21 U.S.C. 601 et seq.) and the Poultry...
78 FR 18306 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... properly labeled and packaged. Meat and poultry products not marked with the mark of inspection and shipped... it displays a currently valid OMB control number. Food Safety and Inspection Service Title... Collection: The Food Safety and Inspection Service (FSIS) has been delegated the authority to exercise the...
This procedure details the procedure for inspecting training files. Training file inspections are performed primarily to ensure that the program requirements are being met and that a current summary of training and experience is being maintained for each individual engaged in the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... Governing Inspection and Certification of Processed Fruits and Vegetables and Related Products AGENCY...: ``Regulations Governing Inspection and Certification of Processed Fruits and Vegetables and Related Products--7..., certifications of quantity and quality, import product inspections, and export certification. Affected public may...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2010-0025] Notice of... Coordinator, Food Safety and Inspection Service, USDA, 1400 Independence Avenue, SW., Room 6065, South...'Connell, Paperwork Reduction Act Coordinator, Food Safety and Inspection Service, USDA, 1400 Independence...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
... DEPARTMENT OF AGRICULTURE Grain Inspection, Packers and Stockyards Administration 7 CFR Part 800... Agriculture's (USDA) Grain Inspection, Packers and Stockyards Administration (GIPSA) is issuing an interim... and individual elevator operators shipping less than 15,000 metric tons during the current and...
Wu, T; Dai, M; Shi, X R; Jiang, Z G; Nuttall, A L
2011-07-01
The cochlear lateral wall generates the endocochlear potential (EP), which creates a driving force for the hair cell transduction current and is essential for normal hearing. Blood flow at the cochlear lateral wall is critically important for maintaining the EP. The vulnerability of the EP to hypoxia suggests that the blood flow in the cochlear lateral wall is dynamically and precisely regulated to meet the changing metabolic needs of the cochlear lateral wall. It has been reported that ATP, an important extracellular signaling molecule, plays an essential role in regulating cochlear blood flow. However, the cellular mechanism underlying ATP-induced regional blood flow changes has not been investigated. In the current study, we demonstrate that 1) the P2X4 receptor is expressed in endothelial cells (ECs) of spiral ligament (SL) capillaries. 2) ATP elicits a characteristic current through P2X4 on ECs in a dose-dependent manner (EC(50) = 0.16 mM). The ATP current has a reversal potential at ∼0 mV; is inhibited by 5-(3-bromophenyl)-1,3-dihydro-2H-benzofuro[3,2-e]-1,4-diazepin-2-one (5-BDBD), LaCl(3), pyridoxal phosphate-6-azo(benzene-2,4-disulfonic acid) tetrasodium salt hydrate (PPADS), and extracellular acidosis; and is less sensitive to α,β-methyleneadenosine 5'-triphosphate (α,β-MeATP) and 2'- and 3'-O-(4-benzoyl-benzoyl) adenosine 5'-triphosphate (BzATP). 3) ATP elicits a transient increase of intracellular Ca(2+) in ECs. 4) In accordance with the above in vitro findings, perilymphatic ATP (1 mM) caused dilation in SL capillaries in vivo by 11.5%. N(ω)-nitro-l-arginine methyl ester hydrochloride (l-NAME), a nonselective inhibitor of nitric oxide synthase, or 5-BDBD, the specific P2X4 inhibitor, significantly blocked the dilation. These findings support our hypothesis that extracellular ATP regulates cochlear lateral blood flow through P2X4 activation in ECs.
Fischer, Nina M; Favrot, Claude; Birkmann, Katharina; Jackson, Michele; Schwarzwald, Colin C; Müller, Martin; Tobler, Kurt; Geisseler, Marco; Lange, Christian E
2014-06-01
The DNA of equine papillomavirus type 2 (EcPV2) is consistently found in equine papillomas and squamous cell carcinomas, indicating a causal association of EcPV2 in the pathogenesis of these tumours; however, little is known about the prevalence of this virus. The aim of this study was to determine the geno- and seroprevalence of EcPV2 in clinically healthy horses in Switzerland. Fifty horses presented to the equine department of the university clinic, displaying no skin or mucous membrane lesions or severe signs of other diseases, were sampled. Cytobrush samples from the penis or vulva and serum samples were collected. To determine the genoprevalence of EcPV2, DNA was extracted from cytobrush samples and tested for viral DNA with a PCR assay amplifying a 338 bp fragment of the E7/E1 region of the viral genome. Seroprevalence was tested using an enzyme-linked immunosorbent assay aimed to detect antibodies against the major capsid protein (L1) of EcPV2. In five of 50 horses (10%), EcPV2-specific DNA was amplified but no antibodies could be detected, whereas in 14 of 50 horses (28%), antibodies against EcPV2 but no DNA were demonstrated. Both antibodies and viral DNA were detected in four of 50 horses (8%). Neither antibodies nor viral DNA were found in 27 of 50 horses (54%). The seroprevalence suggests that EcPV2 is prevalent in the Swiss equine population, while the genoprevalence indicates that currently ongoing infections are less common. The discrepancy between geno- and seroprevalence probably indicates different stages of infection in the tested cohort. © 2014 ESVD and ACVD.
Behringer, Erik J; Socha, Matthew J; Polo-Parada, Luis; Segal, Steven S
2012-01-01
BACKGROUND AND PURPOSE Electrical conduction along endothelium of resistance vessels has not been determined independently of the influence of smooth muscle, surrounding tissue or blood. Two interrelated hypotheses were tested: (i) Intercellular conduction of electrical signals is manifest in endothelial cell (EC) tubes; and (ii) Inhibitors of gap junction channels (GJCs) have confounding actions on EC electrical and Ca2+ signalling. EXPERIMENTAL APPROACH Intact EC tubes were isolated from abdominal muscle feed (superior epigastric) arteries of C57BL/6 mice. Hyperpolarization was initiated with indirect (ACh) and direct (NS309) stimulation of intermediate- and small-conductance Ca2+-activated K+ channels (IKCa/SKCa). Remote membrane potential (Vm) responses to intracellular current injection defined the length constant (λ) for electrical conduction. Dye coupling was evaluated following intracellular microinjection of propidium iodide. Intracellular Ca2+ dynamics were determined using Fura-2 photometry. Carbenoxolone (CBX) or β-glycyrrhetinic acid (βGA) was used to investigate the role of GJCs. KEY RESULTS Steady-state Vm of ECs was −25 mV. ACh and NS309 hyperpolarized ECs by −40 and −60 mV respectively. Electrical conduction decayed monoexponentially with distance (λ∼1.4 mm). Propidium iodide injected into one EC spread into surrounding ECs. CBX or βGA inhibited dye transfer, electrical conduction and EC hyperpolarization reversibly. Both agents elevated resting Ca2+ while βGA inhibited responses to ACh. CONCLUSIONS AND IMPLICATIONS Individual cells were effectively coupled to each other within EC tubes. Inhibiting GJCs with glycyrrhetinic acid derivatives blocked hyperpolarization mediated by IKCa/SKCa channels, regardless of Ca2+ signalling, obviating use of these agents in distinguishing key determinants of electrical conduction along the endothelium. PMID:22168386
Simulation of tropospheric chemistry and aerosols with the climate model EC-Earth
NASA Astrophysics Data System (ADS)
van Noije, T. P. C.; Le Sager, P.; Segers, A. J.; van Velthoven, P. F. J.; Krol, M. C.; Hazeleger, W.
2014-03-01
We have integrated the atmospheric chemistry and transport model TM5 into the global climate model EC-Earth version 2.4. We present an overview of the TM5 model and the two-way data exchange between TM5 and the integrated forecasting system (IFS) model from the European Centre for Medium-Range Weather Forecasts (ECMWF), the atmospheric general circulation model of EC-Earth. In this paper we evaluate the simulation of tropospheric chemistry and aerosols in a one-way coupled configuration. We have carried out a decadal simulation for present-day conditions and calculated chemical budgets and climatologies of tracer concentrations and aerosol optical depth. For comparison we have also performed offline simulations driven by meteorological fields from ECMWF's ERA-Interim reanalysis and output from the EC-Earth model itself. Compared to the offline simulations, the online-coupled system produces more efficient vertical mixing in the troposphere, which likely reflects an improvement of the treatment of cumulus convection. The chemistry in the EC-Earth simulations is affected by the fact that the current version of EC-Earth produces a cold bias with too dry air in large parts of the troposphere. Compared to the ERA-Interim driven simulation, the oxidizing capacity in EC-Earth is lower in the tropics and higher in the extratropics. The methane lifetime is 7% higher in EC-Earth, but remains well within the range reported in the literature. We evaluate the model by comparing the simulated climatologies of surface carbon monoxide, tropospheric and surface ozone, and aerosol optical depth against observational data. The work presented in this study is the first step in the development of EC-Earth into an Earth system model with fully interactive atmospheric chemistry and aerosols.
Michie, Lucy; Cameron, Sharon T; Glasier, Anna; Greed, Elizabeth
2014-07-01
Most women who use emergency contraception (EC) do so because of unprotected sexual intercourse or condom failure and so remain at risk of pregnancy unless they commence an effective method of contraception. In Great Britain, increasingly women now choose to obtain EC from a pharmacy; however, pharmacists do not currently provide effective ongoing contraception. We sought to determine the views of women obtaining EC from pharmacies and clinicians working in sexual and reproductive health care (SRH) about the possibility of pharmacists providing a temporary supply of a progestogen-only pill (POP) together with EC. Self-administered, anonymous questionnaires of (1) women requesting EC from pharmacies in Edinburgh, Scotland and (2) SRH clinicians attending a major UK scientific meeting. A total of 211/232 women completed questionnaires in pharmacies (a 91% response rate). Of those women not using a hormonal method of contraception at the time of EC (n=166; 79%), almost half (44%) wished to use an effective method. Most women (64%) agreed that the option of a pharmacist being able to supply a POP would have been helpful. Among the SRH clinicians, 110 completed questionnaires out of 150 distributed (a 73% response rate). The majority of respondents (92%) were positive about a pharmacist supplying a POP at the time of EC. A reasonable proportion of women requesting EC would like to start using an effective contraceptive method. Both the women and the SRH clinicians we surveyed are positive about the option of a short supply of a POP being provided by the pharmacy in the UK together with EC. Published by the BMJ Publishing Group Limited.
Method for removal of random noise in eddy-current testing system
Levy, Arthur J.
1995-01-01
Eddy-current response voltages, generated during inspection of metallic structures for anomalies, are often replete with noise. Therefore, analysis of the inspection data and results is difficult or near impossible, resulting in inconsistent or unreliable evaluation of the structure. This invention processes the eddy-current response voltage, removing the effect of random noise, to allow proper identification of anomalies within and associated with the structure.
Dalsgaard, Thomas; Bonev, Adrian D.; Nelson, Mark T.
2016-01-01
Key points Increase in endothelial cell (EC) calcium activates calcium‐sensitive intermediate and small conductance potassium (IK and SK) channels, thereby causing hyperpolarization and endothelium‐dependent vasodilatation.Endothelial cells express inward rectifier potassium (Kir) channels, but their role in endothelium‐dependent vasodilatation is not clear.In the mesenteric arteries, only ECs, but not smooth muscle cells, displayed Kir currents that were predominantly mediated by the Kir2.1 isoform.Endothelium‐dependent vasodilatations in response to muscarinic receptor, TRPV4 (transient receptor potential vanilloid 4) channel and IK/SK channel agonists were highly attenuated by Kir channel inhibitors and by Kir2.1 channel knockdown.These results point to EC Kir channels as amplifiers of vasodilatation in response to increases in EC calcium and IK/SK channel activation and suggest that EC Kir channels could be targeted to treat endothelial dysfunction, which is a hallmark of vascular disorders. Abstract Endothelium‐dependent vasodilators, such as acetylcholine, increase intracellular Ca2+ through activation of transient receptor potential vanilloid 4 (TRPV4) channels in the plasma membrane and inositol trisphosphate receptors in the endoplasmic reticulum, leading to stimulation of Ca2+‐sensitive intermediate and small conductance K+ (IK and SK, respectively) channels. Although strong inward rectifier K+ (Kir) channels have been reported in the native endothelial cells (ECs) their role in EC‐dependent vasodilatation is not clear. Here, we test the idea that Kir channels boost the EC‐dependent vasodilatation of resistance‐sized arteries. We show that ECs, but not smooth muscle cells, of small mesenteric arteries have Kir currents, which are substantially reduced in EC‐specific Kir2.1 knockdown (EC‐Kir2.1 −/−) mice. Elevation of extracellular K+ to 14 mm caused vasodilatation of pressurized arteries, which was prevented by endothelial denudation and Kir channel inhibitors (Ba2+, ML‐133) or in the arteries from EC‐Kir2.1 −/− mice. Potassium‐induced dilatations were unaffected by inhibitors of TRPV4, IK and SK channels. The Kir channel blocker, Ba2+, did not affect currents through TRPV4, IK or SK channels. Endothelial cell‐dependent vasodilatations in response to activation of muscarinic receptors, TRPV4 channels or IK/SK channels were reduced, but not eliminated, by Kir channel inhibitors or EC‐Kir2.1 −/−. In angiotensin II‐induced hypertension, the Kir channel function was not altered, although the endothelium‐dependent vasodilatation was severely impaired. Our results support the concept that EC Kir2 channels boost vasodilatory signals that are generated by Ca2+‐dependent activation of IK and SK channels. PMID:26840527
Retrograde Amnesia in Rats, Produced by Electron Beam Exposure.
1983-02-01
radiation. Am J Physiol 215:803-806, 1968. 6. Cronholm, B., and L. Molander. Memory disturbances after electroconvulsive therapy : conditions one month after...stimuli have been demonstrated to be effective in producing RA: e.g., electroconvulsive shock (ECS) (14,19); hypoxia (9); and drugs (3,7). Preliminary...effect argues against ionization as a mechanism of CNS activation. Current induction via electroconvulsive shock (ECS) is known to produce RA (14,19
Enhanced degradation of Orange G by permanganate with the employment of iron anode.
Bu, Lingjun; Shi, Zhou; Zhou, Shiqing
2017-01-01
Iron anode was employed to enhance the degradation of Orange G (OG) by permanganate (EC/KMnO 4 ). Continuously generated Fe 2+ from iron anode facilitated the formation of fresh MnO 2 , which plays a role in catalyzing permanganate oxidation. The EC/KMnO 4 system also showed a better performance to remove OG than Fe 2+ /KMnO 4 , indicating the importance of in situ formed fresh MnO 2 . Besides, the effects of applied current, KMnO 4 dosage, solution pH, and natural organics were evaluated and results demonstrated that high current and oxidant dosage are favorable for OG removal. And the application of iron anode has a promoting effect on the KMnO 4 oxidation over a wide pH range (5.0-9.0), while the Fe 2+ /KMnO 4 process does not. For natural organics, its presence could inhibit OG removal due to its competitive role. And the promoting effect of OG removal by the EC/KMnO 4 process in natural water was confirmed. At last, the EC/KMnO 4 process showed a satisfying performance on the decolorization and mineralization of OG. This study provides a potential technology to enhance permanganate oxidation and broadens the knowledge of azo dye removal.
Oladzad, Sepideh; Fallah, Narges; Nasernejad, Bahram
2017-07-01
In the present study a combination of a novel coalescing oil water separator (COWS) and electrocoagulation (EC) technique was used for treatment of petroleum product contaminated groundwater. In the first phase, COWS was used as the primary treatment. Two different types of coalescing media and two levels of flow rates were examined in order to find the optimum conditions. The effluent of COWS was collected in optimum conditions and was treated using an EC process in the second phase of the research. In this phase, preliminary experiments were conducted in order to investigate the effect of EC reaction time and sedimentation time on chemical oxygen demand (COD) removal efficiency. Best conditions for EC reaction time and sedimentation time were obtained to be 5 min and 30 min, respectively. Response surface methodology was applied to evaluate the effect of initial pH, current density and aeration rate on settling velocity (V s ) and effluent COD. The optimum conditions, for achieving maximum values of V s as well as the values of effluent COD, in the range of results were obtained at conditions of 7, 34 mA·cm -2 and 1.5 L·min -1 for initial pH, current density and aeration rate, respectively.
Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.
2007-01-01
Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-03
... Request for Revision of a Currently Approved Information Collection (Interstate Shipment of Meat and...: Interstate Shipment of Meat and Poultry Products. Type of Request: Revision of an approved information... Federal Meat Inspection Act (FMIA) (21 U.S.C. 601, et seq.) and the Poultry Products Inspection Act (PPIA...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-01
... investigative actions include a surface high- frequency eddy current inspection for cracking of the inner.... The related investigative actions include a surface high-frequency eddy current inspection for... total flight hours and 5,335 total flight cycles. Analysis by the manufacturer revealed that the broken...
Self-consistent modeling of CFETR baseline scenarios for steady-state operation
NASA Astrophysics Data System (ADS)
Chen, Jiale; Jian, Xiang; Chan, Vincent S.; Li, Zeyu; Deng, Zhao; Li, Guoqiang; Guo, Wenfeng; Shi, Nan; Chen, Xi; CFETR Physics Team
2017-07-01
Integrated modeling for core plasma is performed to increase confidence in the proposed baseline scenario in the 0D analysis for the China Fusion Engineering Test Reactor (CFETR). The steady-state scenarios are obtained through the consistent iterative calculation of equilibrium, transport, auxiliary heating and current drives (H&CD). Three combinations of H&CD schemes (NB + EC, NB + EC + LH, and EC + LH) are used to sustain the scenarios with q min > 2 and fusion power of ˜70-150 MW. The predicted power is within the target range for CFETR Phase I, although the confinement based on physics models is lower than that assumed in 0D analysis. Ideal MHD stability analysis shows that the scenarios are stable against n = 1-10 ideal modes, where n is the toroidal mode number. Optimization of RF current drive for the RF-only scenario is also presented. The simulation workflow for core plasma in this work provides a solid basis for a more extensive research and development effort for the physics design of CFETR.
Manenti, Diego R; Módenes, Aparecido N; Soares, Petrick A; Boaventura, Rui A R; Palácio, Soraya M; Borba, Fernando H; Espinoza-Quiñones, Fernando R; Bergamasco, Rosângela; Vilar, Vítor J P
2015-01-01
In this work, the application of an iron electrode-based electrocoagulation (EC) process on the treatment of a real textile wastewater (RTW) was investigated. In order to perform an efficient integration of the EC process with a biological oxidation one, an enhancement in the biodegradability and low toxicity of final compounds was sought. Optimal values of EC reactor operation parameters (pH, current density and electrolysis time) were achieved by applying a full factorial 3(3) experimental design. Biodegradability and toxicity assays were performed on treated RTW samples obtained at the optimal values of: pH of the solution (7.0), current density (142.9 A m(-2)) and different electrolysis times. As response variables for the biodegradability and toxicity assessment, the Zahn-Wellens test (Dt), the ratio values of dissolved organic carbon (DOC) relative to low-molecular-weight carboxylates anions (LMCA) and lethal concentration 50 (LC50) were used. According to the Dt, the DOC/LMCA ratio and LC50, an electrolysis time of 15 min along with the optimal values of pH and current density were suggested as suitable for a next stage of treatment based on a biological oxidation process.
Closely related NDM-1-encoding plasmids from Escherichia coli and Klebsiella pneumoniae in Taiwan.
Chen, Chao-Ju; Wu, Tsu-Lan; Lu, Po-Liang; Chen, Ying-Tsong; Fung, Chang-Phone; Chuang, Yin-Ching; Lin, Jung-Chung; Siu, L Kristopher
2014-01-01
Two plasmids carrying blaNDM-1 isolated from carbapenem-resistant Klebsiella pneumoniae (CR-KP) and carbapenem-resistant Escherichia coli (CR-EC) were sequenced. CR-KP and CR-EC were isolated from two Taiwanese patients without travel histories. Complete sequencing of the plasmids (pLK75 and pLK78) was conducted using a shotgun approach. Annotation of the contigs was performed using the RAST Server, followed by manual inspection and correction. These similar plasmids were obtained from two patients with overlapping stays at the same hospital. The pLK75 and pLK78 plasmids were 56,489-bp and 56,072-bp in length, respectively. Plasmid annotation revealed a common backbone similar to the IncN plasmid pR46. The regions flanking the blaNDM-1 genes in these plasmids were very similar to plasmid pNDM-HU01 in Japan, which contains a complex class 1 integron located next to an ISCR1 element. The ISCR1 element has been suggested to provide a powerful mechanism for mobilising antibiotic resistance genes. Two indigenous NDM-1-producing Enterobacteriaceae cases were identified for the first time in Taiwan, highlighting the alarming introduction of NDM-1-producing Enterobacteriaceae in this region.
Robotic Inspection System for Non-Destructive Evaluation (nde) of Pipes
NASA Astrophysics Data System (ADS)
Mackenzie, L. D.; Pierce, S. G.; Hayward, G.
2009-03-01
The demand for remote inspection of pipework in the processing cells of nuclear plant provides significant challenges of access, navigation, inspection technique and data communication. Such processing cells typically contain several kilometres of densely packed pipework whose actual physical layout may be poorly documented. Access to these pipes is typically afforded through the radiation shield via a small removable concrete plug which may be several meters from the actual inspection site, thus considerably complicating practical inspection. The current research focuses on the robotic deployment of multiple NDE payloads for weld inspection along non-ferritic steel pipework (thus precluding use of magnetic traction options). A fully wireless robotic inspection platform has been developed that is capable of travelling along the outside of a pipe at any orientation, while avoiding obstacles such as pipe hangers and delivering a variety of NDE payloads. An eddy current array system provides rapid imaging capabilities for surface breaking defects while an on-board camera, in addition to assisting with navigation tasks, also allows real time image processing to identify potential defects. All sensor data can be processed by the embedded microcontroller or transmitted wirelessly back to the point of access for post-processing analysis.
Shaaban, Omar M; Hassen, Shaimaa G; Nour, Sanna A; Kames, Mervat A; Yones, Entsar M
2013-03-01
The use of breastfeeding as a method of birth spacing occasionally ends in "unplanned pregnancy." This is due to unexpected expiration of one or more of the lactation amenorrhea method (LAM) prerequisites. The current study tests a new concept that the in-advance provision of single packet of progestogen emergency contraception (EC) pills during the postpartum LAM counseling may decrease the incidence of unplanned pregnancy during breastfeeding. This was a registered two-armed randomized controlled trial (NCT 01111929). Women intending to breastfeed and to postpone pregnancy for 1 year or more were approached. They received adequate postpartum contraceptive counseling. Women intending to use LAM were randomly assigned to one of two groups. The LAM-only group received the proper LAM counseling and did not receive counseling about EC. The LAM-EC group received counseling for both LAM and EC with in-advance provision of one packet of EC pills. They were advised to use these pills if one of the prerequisites of LAM expires and sexual relation has occurred before the initiation of another regular contraceptive protection. All the participants were advised that they need to use another regular method upon expiration of any of the LAM prerequisites. Eligible women were 1158 parturients randomized into two equal groups. Forty-four percent of the women provided with EC used them. Significantly more women in the LAM-EC group initiated regular contraception within or shortly after the first 6 months postpartum when compared with those in the LAM-only group (30.5% vs. 7.3%, respectively; p=.0004). Pregnancy occurred in 5% of the LAM-only group as compared with 0.8% in the LAM-EC group (p=.005). Minimal side effects were reported after EC use. In-advance provision of EC pills can increase the rate of initiation of regular contraception once one or more of the prerequisites of LAM expire. Consequently, the use of EC pills as a temporary backup of LAM can decrease the incidence of unplanned pregnancy during breastfeeding. The use of progestogen EC pill during lactation is safe and tolerable. Copyright © 2013 Elsevier Inc. All rights reserved.
Transplantation of Endothelial Cells to Mitigate Acute and Chronic Radiation Injury to Vital Organs.
Rafii, Shahin; Ginsberg, Michael; Scandura, Joseph; Butler, Jason M; Ding, Bi-Sen
2016-08-01
Current therapeutic approaches for treatment of exposure to radiation involve the use of antioxidants, chelating agents, recombinant growth factors and transplantation of stem cells (e.g., hematopoietic stem cell transplantation). However, exposure to high-dose radiation is associated with severe damage to the vasculature of vital organs, often leading to impaired healing, tissue necrosis, thrombosis and defective regeneration caused by aberrant fibrosis. It is very unlikely that infusion of protective chemicals will reverse severe damage to the vascular endothelial cells (ECs). The role of irradiated vasculature in mediating acute and chronic radiation syndromes has not been fully appreciated or well studied. New approaches are necessary to replace and reconstitute ECs in organs that are irreversibly damaged by radiation. We have set forth the novel concept that ECs provide paracrine signals, also known as angiocrine signals, which not only promote healing of irradiated tissue but also direct organ regeneration without provoking fibrosis. We have developed innovative technologies that enable manufacturing and banking of human GMP-grade ECs. These ECs can be transplanted intravenously to home to and engraft to injured tissues where they augment organ repair, while preventing maladaptive fibrosis. In the past, therapeutic transplantation of ECs was not possible due to a shortage of availability of suitable donor cell sources and preclinical models, a lack of understanding of the immune privilege of ECs, and inadequate methodologies for expansion and banking of engraftable ECs. Recent advances made by our group as well as other laboratories have breached the most significant of these obstacles with the development of technologies to manufacture clinical-scale quantities of GMP-grade and human ECs in culture, including genetically diverse reprogrammed human amniotic cells into vascular ECs (rAC-VECs) or human pluripotent stem cells into vascular ECs (iVECs). This approach provides a path to therapeutic EC transplantation that can be infused concomitantly or sequentially with hematopoietic stem cell transplantation more than 24 h after irradiation to support multi-organ regeneration, thereby improving immediate and long-term survival, while limiting long-term morbidity resulting from nonregenerative damage repair pathways.
Factors associated with dual use of tobacco and electronic cigarettes: A case control study.
Farsalinos, Konstantinos E; Romagna, Giorgio; Voudris, Vassilis
2015-06-01
Many electronic cigarette (EC) users reduce cigarette consumption without completely quitting. It is important to assess the characteristics and experiences of these users, commonly called "dual users", in comparison with EC users who have completely substituted smoking (non-smoking vapers). A questionnaire was uploaded in an online survey tool. EC users were invited to participate irrespective of their current smoking status. Dual users were matched for age and gender with non-smoking vapers. From 19,441 participants, 3682 were dual users. After random 1:1 matching with non-smoking vapers (all of whom were former smokers), 3530 participants in each group were compared. Dual users had longer smoking history, lower daily cigarette consumption and similar cigarette dependence compared to non-smoking vapers. Their daily consumption was reduced after initiation of EC use from 20 to 4 cigarettes per day. Most of them were using ECs daily, however, more were occasional EC users compared to non-smoking vapers. Use of advanced (third generation) devices and daily liquid consumption was lower in dual users compared to non-smoking vapers. The most important reason for initiating EC use was to reduce smoking and exposure of family members to smoke for both groups, but higher scores were given to "avoid smoking ban in public places" by dual users compared to non-smoking vapers. The strongest predictors of being dual user from multivariate analysis were: higher risk perception for ECs (OR=2.27, 95% CI=1.40-3.68), use of first-generation EC devices (OR=1.98, 95% CI=1.47-2.66), use of prefilled cartomizers (OR=1.94, 95% CI=1.23-3.06) and occasional use of ECs (OR=1.62, 95% CI=1.21-2.17). The results of this case-control study indicate that higher risk perceptions about, and less frequent use of, ECs was associated with dual use of ECs and tobacco cigarettes. Since this is a cross-sectional survey, which explores association but not causation, longitudinal studies are warranted to further explore the reasons for dual use. Copyright © 2015 Elsevier B.V. All rights reserved.
Ferrante, Michele; Shay, Christopher F.; Tsuno, Yusuke; William Chapman, G.; Hasselmo, Michael E.
2017-01-01
Abstract Medial entorhinal cortex Layer-II stellate cells (mEC-LII-SCs) primarily interact via inhibitory interneurons. This suggests the presence of alternative mechanisms other than excitatory synaptic inputs for triggering action potentials (APs) in stellate cells during spatial navigation. Our intracellular recordings show that the hyperpolarization-activated cation current (Ih) allows post-inhibitory-rebound spikes (PIRS) in mEC-LII-SCs. In vivo, strong inhibitory-post-synaptic potentials immediately preceded most APs shortening their delay and enhancing excitability. In vitro experiments showed that inhibition initiated spikes more effectively than excitation and that more dorsal mEC-LII-SCs produced faster and more synchronous spikes. In contrast, PIRS in Layer-II/III pyramidal cells were harder to evoke, voltage-independent, and slower in dorsal mEC. In computational simulations, mEC-LII-SCs morphology and Ih homeostatically regulated the dorso-ventral differences in PIRS timing and most dendrites generated PIRS with a narrow range of stimulus amplitudes. These results suggest inhibitory inputs could mediate the emergence of grid cell firing in a neuronal network. PMID:26965902
Ieronimakis, Nicholas; Balasundaram, Gayathri; Reyes, Morayma
2008-01-01
Background Although diseases associated with microvascular endothelial dysfunction are among the most prevalent illnesses to date, currently no method exists to isolate pure endothelial cells (EC) from skeletal muscle for in vivo or in vitro study. Methodology By utilizing multicolor fluorescent-activated cell sorting (FACS), we have isolated a distinct population of Sca-1+, CD31+, CD34dim and CD45− cells from skeletal muscles of C57BL6 mice. Characterization of this population revealed these cells are functional EC that can be expanded several times in culture without losing their phenotype or capabilities to uptake acetylated low-density lipoprotein (ac-LDL), produce nitric oxide (NO) and form vascular tubes. When transplanted subcutaneously or intramuscularly into the tibialis anterior muscle, EC formed microvessels and integrated with existing vasculature. Conclusion This method, which is highly reproducible, can be used to study the biology and role of EC in diseases such as peripheral vascular disease. In addition this method allows us to isolate large quantities of skeletal muscle derived EC with potential for therapeutic angiogenic applications. PMID:18335025
Hrdý, Radim; Kynclová, Hana; Klepáčová, Ivana; Bartošík, Martin; Neužil, Pavel
2017-09-05
We present a portable lock-in amplifier-based electrochemical sensing system. The basic unit (cluster) consists of four electrochemical cells (EC), each containing one pseudoreference electrode (PRE) and one working electrode (WE). All four ECs are simultaneously interrogated, each at different frequencies, with square wave pulses superposed on a sawtooth signal for cyclic voltammetry (CV). Lock-in amplification provides independent read-out of four signals, with excellent noise suppression. We expanded a single cluster system into an array of 16 clusters by using electronic switches. The chip with an array of ECs was fabricated using planar technology with a gap between a WE and a PRE of ≈2 μm, which results in partial microelectrode-type behavior. The basic electrode characterization was performed with the model case using a ferricyanide-ferrocyanide redox couple (Fe 2+ /Fe 3+ ) reaction, performing CV and differential pulse voltammetry (DPV). We then used this system to perform cyclic lock-in voltammetry (CLV) to measure concurrently responses of the four ECs. We repeated this method with all 64 ECs on the chip. The standard deviation of a peak oxidation and reduction current in a single channel consisting of 13 ECs was ≈7.46% and ≈5.6%, respectively. The four-EC configuration in each measured spot allows determination of nonperforming ECs and, thus, to eliminate potential false results. This system is built in a portable palm-size format suitable for point-of-care applications. It can perform either individual or multiple measurements of active compounds, such as biomarkers.
Biomaterials trigger endothelial cell activation when co-incubated with human whole blood.
Herklotz, Manuela; Hanke, Jasmin; Hänsel, Stefanie; Drichel, Juliane; Marx, Monique; Maitz, Manfred F; Werner, Carsten
2016-10-01
Endothelial cell activation resulting from biomaterial contact or biomaterial-induced blood activation may in turn also affect hemostasis and inflammatory processes in the blood. Current in vitro hemocompatibility assays typically ignore these modulating effects of the endothelium. This study describes a co-incubation system of human whole blood, biomaterial and endothelial cells (ECs) that was developed to overcome this limitation. First, human endothelial cells were characterized in terms of their expression of coagulation- and inflammation-relevant markers in response to various activators. Subsequently, their capacity to regulate hemostasis as well as complement and granulocyte activation was monitored in a hemocompatibility assay. After blood contact, quiescent ECs exhibited anticoagulant and anti-inflammatory properties. When they were co-incubated with surfaces exhibiting pro-coagulant or pro-inflammatory characteristics, the ECs down-regulated coagulation but not complement or leukocyte activation. Analysis of intracellular levels of the endothelial activation markers E-selectin and tissue factor showed that co-incubation with model surfaces and blood significantly increased the activation state of ECs. Finally, the coagulation- and inflammation-modulating properties of the ECs were tested after blood/biomaterial exposure. Pre-activation of ECs by biomaterials in the blood induced a pro-coagulant and pro-inflammatory state of the ECs, wherein the pro-coagulant response was higher for biomaterial/blood pre-activated ECs than for TNF-α-pre-activated cells. This work provides evidence that biomaterials, even without directly contacting the endothelium, affect the endothelial activation state with and have consequences for plasmatic and cellular reactions in the blood. Copyright © 2016 Elsevier Ltd. All rights reserved.
Stewart, Christopher J; Auchtung, Thomas A; Ajami, Nadim J; Velasquez, Kenia; Smith, Daniel P; De La Garza, Richard; Salas, Ramiro; Petrosino, Joseph F
2018-01-01
The use of electronic cigarettes (ECs) has increased drastically over the past five years, primarily as an alternative to smoking tobacco cigarettes. However, the adverse effects of acute and long-term use of ECs on the microbiota have not been explored. In this pilot study, we sought to determine if ECs or tobacco smoking alter the oral and gut microbiota in comparison to non-smoking controls. We examined a human cohort consisting of 30 individuals: 10 EC users, 10 tobacco smokers, and 10 controls. We collected cross-sectional fecal, buccal swabs, and saliva samples from each participant. All samples underwent V4 16S rRNA gene sequencing. Tobacco smoking had a significant effect on the bacterial profiles in all sample types when compared to controls, and in feces and buccal swabs when compared to EC users. The most significant associations were found in the gut, with an increased relative abundance of Prevotella ( P = 0.006) and decreased Bacteroides ( P = 0.036) in tobacco smokers. The Shannon diversity was also significantly reduced ( P = 0.009) in fecal samples collected from tobacco smokers compared to controls. No significant difference was found in the alpha diversity, beta-diversity or taxonomic relative abundances between EC users and controls. From a microbial ecology perspective, the current pilot data demonstrate that the use of ECs may represent a safer alternative compared to tobacco smoking. However, validation in larger cohorts and greater understanding of the short and long-term impact of EC use on microbiota composition and function is warranted.
Automation for nondestructive inspection of aircraft
NASA Technical Reports Server (NTRS)
Siegel, M. W.
1994-01-01
We discuss the motivation and an architectural framework for using small mobile robots as automated aids to operators of nondestructive inspection (NDI) equipment. We review the need for aircraft skin inspection, and identify the constraints in commercial airlines operations that make small mobile robots the most attractive alternative for automated aids for NDI procedures. We describe the design and performance of the robot (ANDI) that we designed, built, and are testing for deployment of eddy current probes in prescribed commercial aircraft inspections. We discuss recent work aimed at also providing robotic aids for visual inspection.
Aviation security cargo inspection queuing simulation model for material flow and accountability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olama, Mohammed M; Allgood, Glenn O; Rose, Terri A
Beginning in 2010, the U.S. will require that all cargo loaded in passenger aircraft be inspected. This will require more efficient processing of cargo and will have a significant impact on the inspection protocols and business practices of government agencies and the airlines. In this paper, we develop an aviation security cargo inspection queuing simulation model for material flow and accountability that will allow cargo managers to conduct impact studies of current and proposed business practices as they relate to inspection procedures, material flow, and accountability.
NASA Astrophysics Data System (ADS)
Wu, Xi; Li, Pei-Feng; Liu, Chun-Ying; Zhang, Hong-Hai; Yang, Gui-Peng; Zhang, Sheng-Hui; Zhu, Mao-Xu
2017-12-01
The distributions of dimethylsulfide (DMS), dimethylsulfoniopropionate (DMSP), and acrylic acid (AA) were investigated in the Changjiang Estuary during winter (dry season) and summer (wet season) 2014 and in the East China Sea (ECS) during summer 2015. The rates of dissolved DMSP (DMSPd) degradation with DMS and AA production, DMS degradation, and AA degradation in the ECS were also studied. Significant seasonal variations in DMS(P) and AA concentrations were observed in the Changjiang Estuary with higher values during the wet season than during the dry season. The maximum ratio of AA/chlorophyll a (Chl a) occurred at the mouth of the Changjiang Estuary due to the combined effects of production from DMSP and terrestrial inputs from the Changjiang Estuary. The distributions of DMS(P) and AA in the ECS were dramatically influenced by the Kuroshio Current and the upwelling caused by the Taiwan Warm Current. The ratios of DMS(P)/Chl a and AA/Chl a exhibited similar patterns in the surface seawater of the ECS, which indicated that phytoplankton species and biomass might play important roles in controlling the distributions of DMS(P) and AA. In vertical profiles, high values of AA emerged in the upper water column and bottom seawater of the Changjiang Estuary. Meanwhile, the maxima of DMS(P) and AA generally appeared in the surface or euphotic layer, whereas their minima arose in the bottom seawater of the ECS. The degradation rates of DMSPd, DMS, and AA in the inshore waters were higher than those in the open sea.
Conceptual design of the EU DEMO EC-system: main developments and R&D achievements
NASA Astrophysics Data System (ADS)
Granucci, G.; Aiello, G.; Alberti, S.; Avramidis, K. A.; Braunmüller, F.; Bruschi, A.; Chelis, J.; Franck, J.; Figini, L.; Gantenbein, G.; Garavaglia, S.; Grossetti, G.; Illy, S.; Ioannidis, Z.; Jelonnek, J.; Kalaria, P.; Latsas, G.; Moro, A.; Pagonakis, I. Gr.; Peponis, D.; Poli, E.; Rispoli, N.; Rzesnicki, T.; Scherer, T.; Strauss, D.; Thumm, M.; Tigelis, I.; Tsironis, C.; Wu, C.; Franke, T.; Tran, M. Q.
2017-11-01
For the development of a DEMOnstration Fusion Power Plant the design of auxiliary heating systems is a key activity in order to achieve controlled burning plasma. The present heating mix considers electron cyclotron resonance heating (ECRH), neutral beam injection (NBI) and ion cyclotron resonance heating (ICRH) with a target power to the plasma of about 50 MW for each system. The main tasks assigned to the EC system are plasma breakdown and assisted start-up, heating to L-H transition and plasma current ramp up to burn, MHD stability control and assistance in plasma current ramp down. The consequent requirements are used for the conceptual design of the EC system, from the RF source to the launcher, with an extensive R&D program focused on relevant technologies to be developed. Gyrotron: the R&D and Advanced Developments on EC RF sources are targeting for gyrotrons operating at 240 GHz, considered as optimum EC Current Drive frequency in case of higher magnetic field than for the 2015 EU DEMO1 baseline. Multi-purpose (multi-frequency) and frequency step-tunable gyrotrons are under investigation to increase the flexibility of the system. As main targets an output power of significantly above 1 MW (target: 2 MW) and a total efficiency higher than 60% are set. The principle feasibility at limits of a 236 GHz, conventional-cavity and, alternatively, of a 238 GHz coaxial-cavity gyrotron are under investigation together with the development of a synthetic diamond Brewster-angle window technology. Advanced developments are on-going in the field of multi-stage depressed collector technologies. Transmission line (TL): different TL options are under investigation and a preliminary study of an evacuated quasi-optical multiple-beam TL, considered for a hybrid solution, is presented and discussed in terms of layout, dimensions and theoretical losses. Launcher: remote steering antennas have been considered as a possible launcher solution especially under the constraints to avoid movable mirrors close to the plasma. With dedicated beam tracing calculations, the deposition locations coverage and the wave absorption efficiency have been investigated, considering a selection of frequencies, injection angles and launching points. An option for the EC system structure is proposed in clusters, in order to allow the necessary redundancy and flexibility to guarantee the required EC power in the different phases of the plasma pulse. Number and composition of the clusters are analysed to have high availability and therefore maximum reliability with a minimum number of components.
Nitric oxide releasing hydrogel promotes endothelial differentiation of mouse embryonic stem cells.
Nie, Yan; Zhang, Kaiyue; Zhang, Shuaiqiang; Wang, Dan; Han, Zhibo; Che, Yongzhe; Kong, Deling; Zhao, Qiang; Han, Zhongchao; He, Zuo-Xiang; Liu, Na; Ma, Fengxia; Li, Zongjin
2017-11-01
Transplantation of endothelial cells (ECs) holds great promise for treating various kinds of ischemic diseases. However, the major challenge in ECs-based therapy in clinical applications is to provide high quality and enough amounts of cells. In this study, we developed a simple and efficient system to direct endothelial differentiation of mouse embryonic stem cells (ESCs) using a controllable chitosan nitric oxide (NO)-releasing hydrogel (CS-NO). ESCs were plated onto the hydrogel culture system, and the expressions of differentiation markers were measured. We found that the expression of Flk-1 (early ECs marker) and VE-cadherin (mature ECs marker) increased obviously under the controlled NO releasing environment. Moreover, the Flk-1 upregulation was accompanied by the activation of the phospho-inositide-3 kinase (PI3K)/Akt signaling. We also found that in the presence of the PI3K inhibitor (LY294002), the endothelial commitment of ESCs was abolished, indicating the importance of Akt phosphorylation in the endothelial differentiation of ESCs. Interestingly, in the absence of NO, the activation of Akt phosphorylation alone by using AKT activator (SC-79) did not profoundly promote the endothelial differentiation of ESCs, suggesting an interdependent relationship between NO and the Akt phosphorylation in driving endothelial fate specification of ESCs. Taken together, we demonstrated that NO releasing in a continuous and controlled manner is a simple and efficient method for directing the endothelial differentiation of ESCs without adding growth factors. Fascinating data continues to show that artificial stem cell niche not only serve as a physical supporting scaffold for stem cells proliferation, but also as a novel platform for directing stem cell differentiation. Because of the lack of proper microenvironment for generating therapeutic endothelial cells (ECs) in vitro, the source of ECs for transplantation is the major limitation in ECs-based therapy to clinical applications. The current study established a feeder cell-free, 2-dimensional culture system for promoting the differentiation processes of embryonic stem cells (ESCs) committed to the endothelial lineage via using a nitric oxide (NO) controlled releasing hydrogel (CS-NO). Notably, the NO releasing from the hydrogel could selectively up-regulate Flk-1 (early ECs marker) and VE-cadherin (mature ECs marker) in the absence of growth factors, which was of crucial importance in the endothelial differentiation of ESCs. In summary, the current study proposes a simple and efficient method for directing the endothelial differentiation of ESCs without extra growth factors. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Challenges and benefits on long-term eddy covariance measurements over lakes
NASA Astrophysics Data System (ADS)
Vesala, Timo; Golub, Malgorzata; Desai, Ankur; Heiskanen, Jouni; Provenzale, Maria; Rantakari, Miitta; Ojala, Anne; Mammarella, Ivan
2017-04-01
Eddy Covariance (EC) data on carbon dioxide fluxes is presently available on about 30 lakes but the time series are mostly short, order of one year. Longer EC series together with chamber measurements and appropriate auxiliary data on water column allow for more accurate estimates of the aquatic component in terrestrial carbon balance and analysis of the environmental controls. We discuss on challenges for long-term EC measurements over freshwater ecosystems and demonstrate the benefits of EC data for carbon cycle studies via examples from long-term sites EC sites in Finland. We discuss on the auxiliary measurements needed and the general design of the whole measurement set-up to get representative information. We discuss on challenges related to the CO2 flux partitioning for freshwater ecosystems and introduce a new method to estimate the net primary productivity (NPP) on EC data, which is superior to more traditional methods (bottle incubations, 14C technique) with a poor temporal resolution. Finally, we collected and analyzed CO2 fluxes from 19 globally distributed lakes and reservoirs representing six climate zones. The mean flux was c. 0.3 micro mole / m2 s. We applied a simple upscaling to the direct observations and ended up to the estimate which is about half of the current emission estimate for lentic systems.
ChinaSpec: a network of SIF observations to bridge flux measurements and remote sensing data
NASA Astrophysics Data System (ADS)
Zhang, Y.; Wang, S.; Liu, L.; Ju, W.; Zhu, X.
2017-12-01
Accurately quantifying atmosphere-biosphere interactions across multiple scale still remains a challenge. Remote sensing, especially satellite data, has been widely used as a solution to resolve the broad scale estimation of carbon flux by upscaling the point measurements of eddy covariance (EC) technique. However, critical gaps remain between the EC observations and coarse satellite data due to the scale mismatch. In this regard, it is necessary to build a network of in situ optical observations to bridge the scale-mismatch between EC measurements and satellite remote sensing data. Internationally, a few networks have already been established (e.g., SpecNet and EuroSpec), but still at its early stage. ChinaSpec is a network of linking in situ spectral measurements, especially sun-induce chlorophyll fluorescence (SIF), with point EC observations for better understanding the interactions of atmosphere-biosphere. One main focus of ChinsSpec is to conduct continuous field SIF measurements at multiple EC sites across the mainland of China. This will help us better understand the mechanics of SIF and photosynthesis, and resolve the missing gaps between recent SIF retrievals from coarse satellite data and EC observations. In this presentation, we introduce the background, current stage, and the development of ChinaSpec network.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-23
... Marks, Devices, and Certificates; Egg Products Export Certification AGENCY: Food Safety and Inspection... inspection marks, devices, and certificates. In addition, FSIS is proposing to amend the egg product export... possible under the current system. The Egg Products Inspection Act (EPIA) (21 U.S.C. 1031-1056) does not...
45 CFR 5.52 - Indexes of records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Indexes of records. 5.52 Section 5.52 Public... Records Available for Public Inspection § 5.52 Indexes of records. (a) Inspection and copying. We will maintain and provide for your inspection and copying current indexes of the records described in § 5.51(a...
Progress in Developing Transfer Functions for Surface Scanning Eddy Current Inspections
NASA Astrophysics Data System (ADS)
Shearer, J.; Heebl, J.; Brausch, J.; Lindgren, E.
2009-03-01
As US Air Force (USAF) aircraft continue to age, additional inspections are required for structural components. The validation of new inspections typically requires a capability demonstration of the method using representative structure with representative damage. To minimize the time and cost required to prepare such samples, Electric Discharge machined (EDM) notches are commonly used to represent fatigue cracks in validation studies. However, the sensitivity to damage typically changes as a function of damage type. This requires a mathematical relationship to be developed between the responses from the two different flaw types to enable the use of EDM notched samples to validate new inspections. This paper reviews progress to develop transfer functions for surface scanning eddy current inspections of aluminum and titanium alloys found in structural aircraft components. Multiple samples with well characterized grown fatigue cracks and master gages with EDM notches, both with a range of flaw sizes, were used to collect flaw signals with USAF field inspection equipment. Analysis of this empirical data was used to develop a transfer function between the response from the EDM notches and grown fatigue cracks.
Electrical voltages and resistances measured to inspect metallic cased wells and pipelines
Vail, III, William Banning; Momii, Steven Thomas
2001-01-01
A cased well in the earth is electrically energized with A.C. current. Voltages are measured from three voltage measurement electrodes in electrical contact with the interior of the casing while the casing is electrically energized. In a measurement mode, A.C. current is conducted from a first current carrying electrode within the cased well to a remote second current carrying electrode located on the surface of the earth. In a calibration mode, current is passed from the first current carrying electrode to a third current carrying electrode located vertically at a different position within the cased well, where the three voltage measurement electrodes are located vertically in between the first and third current carrying electrodes. Voltages along the casing and resistances along the casing are measured to determine wall thickness and the location of any casing collars present so as to electrically inspect the casing. Similar methods are employed to energize a pipeline to measure the wall thickness of the pipeline and the location of pipe joints to electrically inspect the pipeline.
Electrical voltages and resistances measured to inspect metallic cased wells and pipelines
Vail III, William Banning; Momii, Steven Thomas
2003-06-10
A cased well in the earth is electrically energized with A.C. current. Voltages are measured from three voltage measurement electrodes in electrical contact with the interior of the casing while the casing is electrically energized. In a measurement mode, A.C. current is conducted from a first current carrying electrode within the cased well to a remote second current carrying electrode located on the surface of the earth. In a calibration mode, current is passed from the first current carrying electrode to a third current carrying electrode located vertically at a different position within the cased well, where the three voltage measurement electrodes are located vertically in between the first and third current carrying electrodes. Voltages along the casing and resistances along the casing are measured to determine wall thickness and the location of any casing collars present so as to electrically inspect the casing. Similar methods are employed to energize a pipeline to measure the wall thickness of the pipeline and the location of pipe joints to electrically inspect the pipeline.
Hooper, Bethany; Verdonck, Michele; Amsters, Delena; Myburg, Michelle; Allan, Emily
2017-09-06
Environmental control systems (ECS) are devices that enable people with severe physical limitations to independently control household appliances. Recent advancements in the area of environmental control technology have led to the development of ECS that can be controlled through mainstream smart-devices. There is limited research on ECS within Australia and no known research addressing smart-device ECS. The current study sought to explore users' experiences with smart-device ECS within Australia. The study followed a single embedded case study method. Participants (n = 5) were existing ECS users with a cervical spinal cord injury. Data were collected through semi-structured interviews with participants, reflexive journals and field notes. An inductive approach was used to analyze the data thematically. The experience of using a smart-device ECS presented both opportunities and costs to users. The opportunities included: independent control, choice, peace of mind, connection, effective resource use, and control over smart-phone functions and applications. The associated costs included: financial, time, frustration, and technical limitations. While findings are similar to previous research into traditional ECS this study indicates that smart-device ECS also offered a new opportunity for users to access mainstream smart-device functions and applications. Future research should investigate methods and resources that practitioners could utilize to better support new users of smart-device ECS. Implications for Rehabilitation As with traditional environmental control systems, users of smart environmental control systems report increased independence, choice and control. Smart-device environmental control systems provide users with access to mainstream smart-device functions and applications, which facilitate connection to family and the outside world. The costs to the user of smart-device environmental control systems include monetary and time investment, dealing with technical limitations and resulting frustration. Prescribers and installers must consider ways to mitigate these costs experienced by users.
Ike, Innocent S; Sigalas, Iakovos; Iyuke, Sunny
2016-01-14
Self-discharge is known to have considerable adverse effects on the performance and application of electrochemical capacitors (ECs). Thus, obtaining an understanding of EC self-discharge mechanism(s) and subsequent derivation and solution of EC models, subject to a particular mechanism or combination of mechanisms during charging, discharging and storage of the device, is the only way to solve problems associated with EC self-discharge. In this review, we summarize recent progress with respect to EC self-discharge by considering the two basic types, electric double-layer capacitors (EDLC) and pseudocapacitors, and their hybrids with their respective charge storage mechanisms, distinguishable self-discharge mechanisms, charge redistribution and charge/energy loss during self-discharge. It was clearly observed that most of the voltage reduction is not purely due to the self-discharge effect but is basically due to redistribution of charge carriers deep inside pores and can therefore be retrieved from a capacitor during long-time discharging. Tuning the self-discharge rate is therefore feasible for single-walled carbon nanotube (SWNT) ECs and can be achieved by simply adjusting the surface chemistry of the nanotubes. The effects of surface chemistry modification on EC self-discharge are very important in studying and suppressing the self-discharge process and will benefit potential applications of ECs with respect to energy retention. Self-discharge can be averted by the use of redox couples that are transformed to insoluble species via electrolysis and adsorbed onto the activated carbon electrode in redox-couple EDLCs, thus transforming the EDLC electrolyte into a material that can store charge. Self-discharge in ECs can also be successfully suppressed by utilizing an ion-interchange layer (ion-exchange membrane), separator or CuSO4 mobile electrolyte that can be converted into an insoluble species by electrolysis during the charge/discharge process. This will help in producing a modern-day blueprint for ECs with high capacitance and improved energy sustainability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for DOT 3AL Cylinders Manufactured of Aluminum Alloy 6351-T6 C Appendix C to Part 180 Transportation... Pt. 180, App. C Appendix C to Part 180—Eddy Current Examination With Visual Inspection for DOT 3AL... with CGA pamphlet C-6.1 (IBR; see § 171.7 of this subchapter). 3. Eddy Current Equipment. A reference...
24 CFR 902.24 - Physical inspection of PHA properties.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Definitions that is currently in effect can be found at the REAC Internet site at http://www.hud.gov/reac or... the individual parts, such as walls, kitchens, bathrooms, and other things, to be inspected in an... document that is currently in effect can be found at the REAC Internet site at http://www.hud.gov/reac or...
ERIC Educational Resources Information Center
Melis, Africa
This document provides a summary of the proceedings of a conference on business start-ups and creation in the 12 member states of the European Community (EC). Section I discusses the current relevance of the issue. Major topics are the explosion of interest in business creation as a means of creating more stable employment and political concern…
Cognitive factors in the close visual and magnetic particle inspection of welds underwater.
Leach, J; Morris, P E
1998-06-01
Underwater close visual inspection (CVI) and magnetic particle inspection (MPI) are major components of the commercial diver's job of nondestructive testing and the maintenance of subsea structures. We explored the accuracy of CVI in Experiment 1 and that of MPI in Experiment 2 and observed high error rates (47% and 24%, respectively). Performance was strongly correlated with embedded figures and visual search tests and was unrelated to length of professional diving experience, formal inspection qualification, or age. Cognitive tests of memory for designs, spatial relations, dotted outlines, and block design failed to correlate with performance. Actual or potential applications of this research include more reliable inspection reporting, increased effectiveness from current inspection techniques, and directions for the refinement of subsea inspection equipment.
Tong, Wing-Chiu; Choi, Cecilia Y.; Karche, Sanjay; Holden, Arun V.; Zhang, Henggui; Taggart, Michael J.
2011-01-01
Uterine contractions during labor are discretely regulated by rhythmic action potentials (AP) of varying duration and form that serve to determine calcium-dependent force production. We have employed a computational biology approach to develop a fuller understanding of the complexity of excitation-contraction (E-C) coupling of uterine smooth muscle cells (USMC). Our overall aim is to establish a mathematical platform of sufficient biophysical detail to quantitatively describe known uterine E-C coupling parameters and thereby inform future empirical investigations of physiological and pathophysiological mechanisms governing normal and dysfunctional labors. From published and unpublished data we construct mathematical models for fourteen ionic currents of USMCs: currents (L- and T-type), current, an hyperpolarization-activated current, three voltage-gated currents, two -activated current, -activated current, non-specific cation current, - exchanger, - pump and background current. The magnitudes and kinetics of each current system in a spindle shaped single cell with a specified surface area∶volume ratio is described by differential equations, in terms of maximal conductances, electrochemical gradient, voltage-dependent activation/inactivation gating variables and temporal changes in intracellular computed from known fluxes. These quantifications are validated by the reconstruction of the individual experimental ionic currents obtained under voltage-clamp. Phasic contraction is modeled in relation to the time constant of changing . This integrated model is validated by its reconstruction of the different USMC AP configurations (spikes, plateau and bursts of spikes), the change from bursting to plateau type AP produced by estradiol and of simultaneous experimental recordings of spontaneous AP, and phasic force. In summary, our advanced mathematical model provides a powerful tool to investigate the physiological ionic mechanisms underlying the genesis of uterine electrical E-C coupling of labor and parturition. This will furnish the evolution of descriptive and predictive quantitative models of myometrial electrogenesis at the whole cell and tissue levels. PMID:21559514
Lower cost offshore field development utilizing autonomous vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frisbie, F.R.; Vie, K.J.; Welch, D.W.
1996-12-31
The offshore oil and gas industry has the requirement to inspect offshore oil and gas pipelines for scour, corrosion and damage as well as inspect and intervene on satellite production facilities. This task is currently performed with Remotely Operated Vehicles (ROV) operated from dynamically positioned (DP) offshore supply or diving support boats. Currently, these tasks are expensive due to the high day rates for DP ships and the slow, umbilical impeded, 1 knot inspection rates of the tethered ROVs, Emerging Autonomous Undersea Vehicle (AUV) technologies offer opportunities to perform these same inspection tasks for 50--75% lower cost, with comparable ormore » improved quality. The new generation LAPV (Linked Autonomous Power Vehicles) will operate from fixed facilities such as TLPs or FPFs and cover an operating field 10 kms in diameter.« less
Eddy current system for inspection of train hollow axles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chady, Tomasz; Psuj, Grzegorz; Sikora, Ryszard
2014-02-18
The structural integrity of wheelsets used in rolling stock is of great importance to the safety. In this paper, electromagnetic system with an eddy current transducer suitable for the inspection of hollow axles have been presented. The transducer was developed to detect surface braking defects having depth not smaller than 0.5 mm. Ultrasound technique can be utilized to inspect the whole axle, but it is not sufficiently sensitive to shallow defects located close to the surface. Therefore, the electromagnetic technique is proposed to detect surface breaking cracks that cannot be detected by ultrasonic technique.
Feng, Qingshan; Li, Rui; Nie, Baohua; Liu, Shucong; Zhao, Lianyu; Zhang, Hong
2016-01-01
Girth weld cracking is one of the main failure modes in oil and gas pipelines; girth weld cracking inspection has great economic and social significance for the intrinsic safety of pipelines. This paper introduces the typical girth weld defects of oil and gas pipelines and the common nondestructive testing methods, and systematically generalizes the progress in the studies on technical principles, signal analysis, defect sizing method and inspection reliability, etc., of magnetic flux leakage (MFL) inspection, liquid ultrasonic inspection, electromagnetic acoustic transducer (EMAT) inspection and remote field eddy current (RFDC) inspection for oil and gas pipeline girth weld defects. Additionally, it introduces the new technologies for composite ultrasonic, laser ultrasonic, and magnetostriction inspection, and provides reference for development and application of oil and gas pipeline girth weld defect in-line inspection technology. PMID:28036016
Code of Federal Regulations, 2010 CFR
2010-01-01
... basic State Factor (SF). The data sources used for each criteria is believed to be the most current and... given the criteria. The transition formula first checks whether the current year's basic formula... year's BFA). EC14NO91.000 If the current year's State BFA is not within this transition range, the...
Sex Differences Influencing Micro- and Macrovascular Endothelial Phenotype In Vitro.
Huxley, Virginia H; Kemp, Scott S; Schramm, Christine; Sieveking, Steve; Bingaman, Susan; Yu, Yang; Zaniletti, Isabella; Stockard, Kevin; Wang, Jianjie
2018-06-09
Endothelial dysfunction is an early hallmark of multiple disease states that also display sex differences with respect to age of onset, frequency, and severity. Results of in vivo studies of basal and stimulated microvascular barrier function revealed sex differences difficult to ascribe to specific cells or environmental factors. The present study evaluated endothelial cells (EC) isolated from macro- and/or microvessels of reproductively mature rats under the controlled conditions of low-passage culture to test the assumption that EC phenotype would be sex-independent. The primary finding was that EC, regardless of where they are derived, retain a sex-bias in low-passage culture, independent of varying levels of reproductive hormones. Implications of the work include the fallacy of expecting a universal set of mechanisms derived from study of EC from one sex and/or one vascular origin to apply uniformly to all EC under unstimulated conditions no less in the disease state. Vascular endothelial cells (EC) are heterogeneous with respect to phenotype reflecting at least organ of origin, location within the vascular network, and physical forces. Sex, as an independent influence on EC functions in health or etiology, susceptibility, and progression of dysfunction in numerous disease states, has been largely ignored. The current study focussed on EC isolated from aorta (macrovascular) and skeletal muscle vessels (microvascular) of age-matched male and female rats under identical conditions of short term (passage 4) culture. We tested the hypothesis that genomic sex would not influence endothelial growth, wound healing, morphology, lactate production, or messenger RNA and protein expression of key proteins (sex hormone receptors for androgen (AR) and oestrogen (ERα and ERβ); PECAM-1 and VE-CAD mediating barrier function; α v β 3 and N-Cadherin influencing matrix interactions; ICAM-1 and VCAM-1 mediating EC/white cell adhesion). The hypothesis was rejected as EC origin (macro- versus microvessel) and sex influenced multiple phenotypic characteristics. Statistical model analysis of EC growth demonstrated an hierarchy of variable importance, recapitulated for other phenotypic characteristics, wherein predictions assuming EC homogeneity < Sex < Vessel Origin < Sex and Vessel Origin. Further, patterns of EC mRNA expression by vessel origin and by sex did not predict protein expression. Overall the study demonstrated that accurate assessment of sex-linked EC dysfunction first requires understanding of EC function by position in the vascular tree and by sex. Results from a single EC tissue source/species/sex cannot provide universal insight into the mechanisms regulating in vivo endothelial function in health, no less disease. (250) This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-14
..., Compulsory Ship Inspections. Form No.: N/A. Type of Review: Extension of a currently approved collection... notation in the ship's station log that certifies that the ship has/has not passed inspection, that..., upon a finding that the public interest would be served, grant a waiver of the annual inspection...
Effects and Side Effects of Flemish School Inspection
ERIC Educational Resources Information Center
Penninckx, Maarten; Vanhoof, Jan; De Maeyer, Sven; Van Petegem, Peter
2016-01-01
Despite the increased importance of school inspection in recent years, the current knowledge base does not provide a clear view on the effects and side effects of being inspected. More evidence is needed in more diverse educational contexts. This article responds to this need with a quantitative study on the effects and side effects of school…
75 FR 16651 - Airworthiness Directives; The Boeing Company Model 747-200C and -200F Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... upper chord of the upper deck floor beams in Area 5, and the inspection for fatigue cracking in the.... That AD currently requires repetitive inspections to find fatigue cracking in the floor panel... additional repetitive inspections to find fatigue cracking in the floor panel attachment fastener holes of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... listed above. The existing AD currently requires repetitively inspecting the elevator control tabs for... section. We are proposing this AD to add new repetitive inspections of the elevator control tabs. If these inspections are not done, excessive free-play in the elevator control tabs could develop. This condition could...
Fiber-Optic Sensing for In-Space Inspection
NASA Technical Reports Server (NTRS)
Pena, Francisco; Richards, W. Lance; Piazza, Anthony; Parker, Allen R.; Hudson, Larry D.
2014-01-01
This presentation provides examples of fiber optic sensing technology development activities performed at NASA Armstrong. Examples of current and previous work that support in-space inspection techniques and methodologies are highlighted.
Ingólfsson, Helgi I.; Koeppe, Roger E.; Andersen, Olaf S.
2011-01-01
Green tea's health benefits have been attributed to its major polyphenols, the catechins: (−)-epigallocatechin gallate (EGCG), (−)-epicatechin gallate (ECG), (−)-epigallocatechin (EGC), and epicatechin (EC). Catechins (especially EGCG) modulate a wide range of biologically important molecules, including many membrane proteins. Yet, little is known about their mechanism(s) of action. We tested the catechins' bilayer-modifying potency using gramicidin A (gA) channels as molecular force probes. All the catechins alter gA channel function and modify bilayer properties, with a 500-fold range in potency (EGCG > ECG >> EGC > EC). Additionally, the gallate group causes current block, as evident by brief downward current transitions (flickers). PMID:21896274
Data Interconnection Exploration
NASA Technical Reports Server (NTRS)
Iniguez, Alfredo Bravo
2011-01-01
This project involves innovating the way the Quality Assurance organization at the Jet Propulsion Laboratory (JPL) tracks the receiving inspection of JPL Critical Items (JCI) procured from suppliers. The Quality Assurance organization uses a Microsoft Access based front-end to enter items into an inspection queue. The current design has grown to be much more than was expected when the inspection queue system was created in 2007. The goal is to migrate to a web based solution that will allow the handling of more data, multiple input interfaces, and customizable display options. This has been achieved by implementing a divided tables scheme, the use of ColdFusion programming language, and the usage of Web 2.0 technologies such as AJAX and jQuery. These updates will allow for future expansion as well as the standardization of inspection queues for the Quality Assurance organization. When engineers and scientists order flight hardware, they cannot use it straight away. After a spacecraft or a satellite has been launched, it will be impossible to repair; therefore, the parts used must be inspected to make sure they are operating correctly and within the required specifications. The task of inspecting these JPL Critical Items (JCI) falls on the Quality Assurance organization. One of the tools the receiving inspection group uses is a database to maintain a queue of inspections that need to be done and of inspections that have been completed. The current Access interface has worked well but increased amounts of data, multiple input interfaces, and changes to how data is handled have made it necessary to seek a new way of organizing items for inspection. In addition, the different inspection groups have recently been merged and each has different ways of keeping track of inspection information. The ultimate goal is for the new group to have one shared inspection queue and website. To achieve this goal, I have been working with Ian Luczon of Procurement Quality Assurance and 3 Myers Hawkins, another intern, to not only create the new queue for receiving inspection but also a central web portal for the newly combined inspection group.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... inspection AD 97-17-04R1, and to allow automatic eddy current inspection per engine manual Section 72-33-31.... That AD currently requires revisions to the engine manufacturer's time limits section (TLS) to include... modifies the TLS of the manufacturer's engine manual and an air carrier's approved continuous airworthiness...
NASA Technical Reports Server (NTRS)
Delgado, Irebert R.; Steinetz, Bruce M.; Rimnac, Clare M.; Lewandowski, John J.
2008-01-01
The fatigue crack growth behavior of Grainex Mar-M 247 is evaluated for NASA s Turbine Seal Test Facility. The facility is used to test air-to-air seals primarily for use in advanced jet engine applications. Because of extreme seal test conditions of temperature, pressure, and surface speeds, surface cracks may develop over time in the disk bolt holes. An inspection interval is developed to preclude catastrophic disk failure by using experimental fatigue crack growth data. By combining current fatigue crack growth results with previous fatigue strain-life experimental work, an inspection interval is determined for the test disk. The fatigue crack growth life of the NASA disk bolt holes is found to be 367 cycles at a crack depth of 0.501 mm using a factor of 2 on life at maximum operating conditions. Combining this result with previous fatigue strain-life experimental work gives a total fatigue life of 1032 cycles at a crack depth of 0.501 mm. Eddy-current inspections are suggested starting at 665 cycles since eddy current detection thresholds are currently at 0.381 mm. Inspection intervals are recommended every 50 cycles when operated at maximum operating conditions.
Hawkes, A L; Quinn, M; Gebski, V; Armes, J; Brennan, D; Janda, M; Obermair, A
2014-09-01
Endometrial adenocarcinoma (EC) is the most common gynaecologic cancer. Up to 90% of EC patients are obese which poses a health threat to patients post-treatment. Standard treatment for EC includes hysterectomy, although this has significant side effects for obese women at high risk of surgical complications and for women of childbearing age. This trial investigates the effectiveness of non-surgical or conservative treatment options for obese women with early stage EC. The primary aim is to determine the efficacy of: levonorgestrel intrauterine device (LNG-IUD); with or without metformin (an antidiabetic drug); and with or without a weight loss intervention to achieve a pathological complete response (pCR) in EC at six months from study treatment initiation. The secondary aim is to enhance understanding of the molecular processes and to predict a treatment response by investigating EC biomarkers. An open label, three-armed, randomised, phase-II, multi-centre trial of LNG-IUD ± metformin ± weight loss intervention. 165 participants from 28 centres are randomly assigned in a 3:3:5 ratio to the treatment arms. Clinical, quality of life and health behavioural data will be collected at baseline, six weeks, three and six months. EC biomarkers will be assessed at baseline, three and six months. There is limited prospective evidence for conservative treatment for EC. Trial results could benefit patients and reduce health system costs through a reduction in hospitalisations and through lower incidence of adverse events currently observed with standard treatment. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
Williams, Monique; Bozhilov, Krassimir; Ghai, Sanjay; Talbot, Prue
2017-01-01
Our purpose was to quantify 36 inorganic chemical elements in aerosols from disposable electronic cigarettes (ECs) and electronic hookahs (EHs), examine the effect of puffing topography on elements in aerosols, and identify the source of the elements. Thirty-six inorganic chemical elements and their concentrations in EC/EH aerosols were determined using inductively coupled plasma optical emission spectroscopy, and their source was identified by analyzing disassembled atomizers using scanning electron microscopy and energy dispersive X-ray spectroscopy. Of 36 elements screened, 35 were detected in EC/EH aerosols, while only 15 were detected in conventional tobacco smoke. Some elements/metals were present in significantly higher concentrations in EC/EH aerosol than in cigarette smoke. Concentrations of particular elements/metals within EC/EH brands were sometimes variable. Aerosols generated at low and high air-flow rates produced the same pattern of elements, although the total element concentration decreased at the higher air flow rate. The relative amount of elements in the first and last 60 puffs was generally different. Silicon was the dominant element in aerosols from all EC/EH brands and in cigarette smoke. The elements appeared to come from the filament (nickel, chromium), thick wire (copper coated with silver), brass clamp (copper, zinc), solder joints (tin, lead), and wick and sheath (silicon, oxygen, calcium, magnesium, aluminum). Lead was identified in the solder and aerosol of two brands of EHs (up to 0.165 μg/10 puffs). These data show that EC/EH aerosols contain a mixture of elements, including heavy metals, with concentrations often significantly higher than in conventional cigarette smoke. While the health effects of inhaling mixtures of heated metals is currently not known, these data will be valuable in future risk assessments involving EC/EH elements/metals.
Auchtung, Thomas A.; Ajami, Nadim J.; Velasquez, Kenia; De La Garza, Richard; Petrosino, Joseph F.
2018-01-01
Background The use of electronic cigarettes (ECs) has increased drastically over the past five years, primarily as an alternative to smoking tobacco cigarettes. However, the adverse effects of acute and long-term use of ECs on the microbiota have not been explored. In this pilot study, we sought to determine if ECs or tobacco smoking alter the oral and gut microbiota in comparison to non-smoking controls. Methods We examined a human cohort consisting of 30 individuals: 10 EC users, 10 tobacco smokers, and 10 controls. We collected cross-sectional fecal, buccal swabs, and saliva samples from each participant. All samples underwent V4 16S rRNA gene sequencing. Results Tobacco smoking had a significant effect on the bacterial profiles in all sample types when compared to controls, and in feces and buccal swabs when compared to EC users. The most significant associations were found in the gut, with an increased relative abundance of Prevotella (P = 0.006) and decreased Bacteroides (P = 0.036) in tobacco smokers. The Shannon diversity was also significantly reduced (P = 0.009) in fecal samples collected from tobacco smokers compared to controls. No significant difference was found in the alpha diversity, beta-diversity or taxonomic relative abundances between EC users and controls. Discussion From a microbial ecology perspective, the current pilot data demonstrate that the use of ECs may represent a safer alternative compared to tobacco smoking. However, validation in larger cohorts and greater understanding of the short and long-term impact of EC use on microbiota composition and function is warranted. PMID:29736335
de Souza, Paulo S A; Cerqueira, Alexandre A; Rigo, Michelle M; de Paiva, Julieta L; Couto, Rafael S P; Merçon, Fábio; Perez, Daniel V; Marques, Monica R C
2017-05-01
This study aims to evaluate the effects of oilfield water (OW), treated by a hybrid process of electrocoagulation and reverse osmosis (EC-RO), on seed germination and early growth characteristics of sunflower (Heliantus annus L.). In the EC step, tests were conducted with 28.6 A m -2 current density and 4 min. reaction time. In the RO step, the system was operated with 1 L min -1 constant flow and 2 MPa, 2.5 MPa and 3 MPa feed pressures. In all feed pressures, RO polymeric membranes achieved very high removals of chemical oxygen demand (up to 89%) and oils and greases (100%) from EC-treated effluent. In best feed pressure (2.5 MPa), turbidity, total dissolved salts, electrical conductivity, salinity, toxic ions and sodium adsorption ratio values attained internationally recognized standards for irrigation water. Using EC-RO (feed pressure:2.5 MPa) treated OW, germinated sunflower seeds percentage (86 ± 6%), speed of germination (30 ± 2) and biomass production (49 ± 5 mg) were statistically similar to control (distilled water) results. Vigor index average values obtained using OW treated by EC-RO (3871)were higher than that obtained by OW water treated by EC (3300). The results of this study indicate that EC-RO seems to be a promising alternative for treatment of OW aiming sunflower crops irrigation, since the use of this treated effluent did not affect adversely seed germination and seedling development, and improved seedling vigor. Furthermore, OW treatment by EC-RO reduces sodium levels into acceptable standards values avoiding soil degradation.
Aliyu, A B; Saleha, A A; Jalila, A; Zunita, Z
2016-08-02
The significant role of retail poultry meat as an important exposure pathway for the acquisition and transmission of extended spectrum β-lactamase-producing Escherichia coli (ESBL-EC) into the human population warrants understanding concerning those operational practices associated with dissemination of ESBL-EC in poultry meat retailing. Hence, the objective of this study was to determine the prevalence, spatial distribution and potential risk factors associated with the dissemination of ESBL-EC in poultry meat retail at wet-markets in Selangor, Malaysia. Poultry meat (breast, wing, thigh, and keel) as well as the contact surfaces of weighing scales and cutting boards were sampled to detect ESBL-EC by using culture and disk combination methods and polymerase chain reaction assays. Besides, questionnaire was used to obtain data and information pertaining to those operational practices that may possibly explain the occurrence of ESBL-EC. The data were analysed using logistic regression analysis at 95 % CI. The overall prevalence of ESBL-EC was 48.8 % (95 % CI, 42 - 55 %). Among the risk factors that were explored, type of countertop, sanitation of the stall environment, source of cleaning water, and type of cutting board were found to be significantly associated with the presence of ESBL-EC. Thus, in order to prevent or reduce the presence of ESBL-EC and other contaminants at the retail-outlet, there is a need to design a process control system based on the current prevailing practices in order to reduce cross contamination, as well as to improve food safety and consumer health.
Awareness and practice of emergency contraception at a private university in Nigeria.
Awoleke, Jacob Olumuyiwa; Adanikin, Abiodun Idowu; Awoleke, Adeola; Odanye, Moyinoluwa
2015-06-04
The pursuit of formal education now causes many people in developing countries to marry later in life, thereby leading to increased premarital sex and unintended pregnancies. Efforts have been made to characterize awareness and use of emergency contraception (EC) among undergraduate students in public universities in Nigeria; however, it is not known if students in private tertiary institutions adopt different practices or if having an affluent family background plays a role. This pilot study therefore aimed to assess the awareness and use of EC among students at a private Nigerian university toward assisting education planners in developing strategies in improving students' reproductive well-being. Out of 94 female students, 42 (44.7%) had sexual experience, but only 32 (34.0%) were currently sexually active. Six students (6.4%) had had unwanted pregnancies, of which all but one were terminated. Fifty-seven respondents (60.6%) were aware of EC, though only 10 (10.6%) ever practiced it. The greatest source of EC information was from health workers and peers; the lowest source was family or relatives. Most respondents desired orientation and availability of EC on campus. EC awareness among the students was predicted by upper social class background (adjusted odds ratio [OR], 2.73; 95% confidence interval [CI], 1.06-7.45) and upbringing in the Federal Capital Territory (adjusted OR, 4.45; 95% CI, 1.56-14.22). Though awareness of EC was higher among the private university students in this study than at most public universities, there was no difference in EC usage. A high pregnancy termination rate was observed; dilatation and curettage were mainly adopted. In Nigeria, youth-friendly reproductive health information and access should not be limited to government-owned tertiary institutions but also extended to private ones.
Gong, Chenhao; Zhang, Zhongguo; Li, Haitao; Li, Duo; Wu, Baichun; Sun, Yuwei; Cheng, Yanjun
2014-06-15
The electrocoagulation (EC) process was used to pretreat wastewater from the manufacture of wet-spun acrylic fibers, and the effects of varying the operating parameters, including the electrode area/wastewater volume (A/V) ratio, current density, interelectrode distance and pH, on the EC treatment process were investigated. About 44% of the total organic carbon was removed using the optimal conditions in a 100 min procedure. The optimal conditions were a current density of 35.7 mA cm(-2), an A/V ratio of 0.28 cm(-1), a pH of 5, and an interelectrode distance of 0.8 cm. The biodegradability of the contaminants in the treated water was improved by the EC treatment (using the optimal conditions), increasing the five-day biological oxygen demand/chemical oxygen demand ratio to 0.35, which could improve the effectiveness of subsequent biological treatments. The improvement in the biodegradability of the contaminants in the wastewater was attributed to the removal and degradation of aromatic organic compounds, straight-chain paraffins, and other organic compounds, which we identified using gas chromatography-mass spectrometry and Fourier transform infrared spectroscopy. The EC process was proven to be an effective alternative pretreatment for wastewater from the manufacture of wet-spun acrylic fibers, prior to biological treatments. Copyright © 2014 Elsevier B.V. All rights reserved.
Department of Defense counterdrug technology development of non-intrusive inspection systems
NASA Astrophysics Data System (ADS)
Pennella, John J.
1997-02-01
The Naval Surface Warfare Center Dahlgren Division serves as the executive agent for the DoD's Contraband Detection and Cargo Container Inspection Technology Development Program. The goal of the DoD non-intrusive inspection (NII) program is to develop prototype equipment that can be used to inspect containers and vehicles, quickly and in large numbers without unnecessary delays in the movement of legitimate cargo. This paper summaries the past accomplishments of the program, current status, and future plans.
Arenas, M D; Bernat, A; Ramos, R; Berdud, I; Blanco, A
2009-01-01
To guarantee continuity and equity in the clinical assistance of patients on hemodialysis in extrahospitalary centers (EC) a close relationship and a good level of communication between them and their reference hospitals (RH) is essential. The aim of this study was to assess the present situation of this relationship in our country (Spain) so as to be able to detect improvement opportunities. Descriptive and transversal study using two self-report anonymous surveys: one for EC (81 questions) and one for RH (56 questions) sent by e-mail to all Spanish EC and RH registered in the Spanish Society of Nephrology. We received answers from 80 EC and 30 RH. 70% of the EC were managed by multinational companies; only 16 % EC were placed in a hospital. 64% of the EC need to employ non-nephrological medical staff. Nearly 40% of the EC nephrologists also go on duty at their RH. More than three quarters of the EC nephrologists are alone during their workday. Bidirectional telephone communication is very frequent between EC and RH. Around a third of the patients sent from RH to EC arrive without current viral serology and/or without a functioning vascular access. Most of the patients sent from EC to RH bring an up-to-date complete medical report. 41,3 % of the EC answered that they were usually consulted by their RH doctor colleagues about decisions to be taken regarding their patients. Routine blood and other medical protocol tests of CE are well defined in the formal agreement with their RH in 65 % of the cases, although they can be modified by the EC through consensus with the RH in more than 50 % of the cases. 60 % of the EC can directly consult other specialists in the RH but more than 50 % need to do so through the RH nephrologist. Parenteral medication used in the ECs is mostly supplied by their RH, but a third of ECs have some limitations with uncommon or not concert-specified parenteral drugs. RHs refer that most of the vascular accesses are done in the hospital, whereas ECs say that this is true only in half of the cases. More than a third of the fistulae of predialysis patients are done in the ECs as part of their collaboration with RHs. The majority of ECs can share the decision about patients' inclusion in renal transplant waiting list. In only a fifth of the cases is there a common database between CE and RH, and less than half share common protocols or objectives. 62,5% of CEs participate with RHs in clinical trials. More than half of the dialysis private companies provide continuous training and education to their ECs personnel, either directly through the company or facilitating assistance to courses or congresses. Some of the relationship aspects that appear to be clearly improvable are: CEs nephrologist solitude and their limited access to continuous training and education, an adequate referral of the patients from the RHs, CEs nephrologist's autonomy at making consultations to specialists or their limitations when asking for hospital medications. A closer relationship between CEs and RHs is of the utmost importance in guaranteeing continuity and equity in the clinical assistance of our hemodialysis patients. The creation of a debate forum would favour discussion and common resolution of such aspects.
Evaluation of overhead support inspection program.
DOT National Transportation Integrated Search
2015-01-01
This study evaluated the adequacy and frequency of the current structural support inspection program for overhead : sign supports (including bridge mounted), mast arm signal supports and high mast light supports. While ODOT provides : statewide guida...
Investigation of low leakage current radiation detectors on n-type 4H-SiC epitaxial layers
NASA Astrophysics Data System (ADS)
Nguyen, Khai V.; Chaudhuri, Sandeep K.; Mandal, Krishna C.
2014-09-01
The surface leakage current of high-resolution 4H-SiC epitaxial layer Schottky barrier detectors has been improved significantly after surface passivations of 4H-SiC epitaxial layers. Thin (nanometer range) layers of silicon dioxide (SiO2) and silicon nitride (Si3N4) were deposited on 4H-SiC epitaxial layers using plasma enhanced chemical vapor deposition (PECVD) on 20 μm thick n-type 4H-SiC epitaxial layers followed by the fabrication of large area (~12 mm2) Schottky barrier radiation detectors. The fabricated detectors have been characterized through current-voltage (I-V), capacitance-voltage (C-V), and alpha pulse height spectroscopy measurements; the results were compared with that of detectors fabricated without surface passivations. Improved energy resolution of ~ 0.4% for 5486 keV alpha particles was observed after passivation, and it was found that the performance of these detectors were limited by the presence of macroscopic and microscopic crystal defects affecting the charge transport properties adversely. Capacitance mode deep level transient studies (DLTS) revealed the presence of a titanium impurity related shallow level defects (Ec-0.19 eV), and two deep level defects identified as Z1/2 and Ci1 located at Ec-0.62 and ~ Ec-1.40 eV respectively.
Removal of emerging contaminants from the environment by adsorption.
Sophia A, Carmalin; Lima, Eder C
2018-04-15
Emerging contaminants (EC's) are pollutants of growing concern. They are mainly organic compounds such as: pesticides, pharmaceuticals and personal care products, hormones, plasticizers, food additives, wood preservatives, laundry detergents, surfactants, disinfectants, flame retardants, and other organic compounds that were found recently in natural wastewater stream generated by human and industrial activities. A majority of ECs does not have standard regulations and could lead to lethal effects on human and aquatic life even at small concentrations. The conventional primary and secondary water treatment plants do not remove or degrade these toxic pollutants efficiently and hence need cost effective tertiary treatment method. Adsorption is a promising method worldwide for EC removal since it is low initial cost for implementation, highly-efficient and has simple operating design. Research has shown that the application of different adsorbents such as, activated carbons(ACs), modified biochars (BCs), nanoadsorbents (carbon nanotubes and graphene), composite adsorbents, and other are being used for EC's removal from water and wastewater. The current review intends to investigate adsorption process as an efficient method for the treatment of ECs. The mechanism of adsorption has also been discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Tunable high-power blue external cavity semiconductor laser
NASA Astrophysics Data System (ADS)
Ding, Ding; Lv, Xueqin; Chen, Xinyi; Wang, Fei; Zhang, Jiangyong; Che, Kaijun
2017-09-01
A commercially available high-power GaN-based blue laser diode has been operated in a simple Littrow-type external cavity (EC). Two kinds of EC configurations with the grating lines perpendicular (A configuration) and parallel (B configuration) to the p-n junction are evaluated. Good performance has been demonstrated for the EC laser with B configuration due to the better mode selection effect induced by the narrow feedback wavelength range from the grating. Under an injection current of 1100 mA, the spectral linewidth is narrowed significantly down to ∼0.1 nm from ∼1 nm (the free-running width), with a good wavelength-locking behavior and a higher than 35 dB-amplified spontaneous emission suppression ratio. Moreover, a tuning bandwidth of 3.6 nm from 443.9 nm to 447.5 nm is realized with output power of 1.24 W and EC coupling efficiency of 80% at the central wavelength. The grating-coupled blue EC laser with narrow spectral linewidth, flexible wavelength tunability, and high output power shows potential applications in atom cooling and trapping, high-resolution spectroscopy, second harmonic generation, and high-capacity holographic data storage.
Studies on absorption of EC waves in assisted startup experiment on FTU
NASA Astrophysics Data System (ADS)
Granucci, G.; Ricci, D.; Farina, D.; Figini, L.; Iraji, D.; Tudisco, O.; Ramponi, G.; Bin, W.
2012-09-01
Assistance of EC wave for plasma breakdown and current ramp up is the proposed scenario for the ITER case, characterized by low toroidal electric field. The experimental results on many tokamaks clearly indicate the capabilities of the proposed scheme to have a robust breakdown in ITER. The key aspect of this technique is the EC power required, strongly related to the absorption of the wave in the initial stage of plasma formation. This aspect is generally neglected due to the diagnostics difficulties in the plasma formation phase. As a consequence a multi-pass absorption scheme is usually considered reasonable, leading to a strong absorption after many reflections on the walls. The present study exploits the high temporal and spatial resolution of the fast scanning interferometer of FTU together with the measure of residual power obtained by a sniffer probe. The absorbed EC power is calculated considering also the polarization rotation and the subsequent mode conversion after incidence on the internal wall and compared with that derived from experimental data. The resulting EC power distribution can explain differences observed between perpendicular and oblique injection results, indicating future investigations to define ITER power requirements.
Endothelial dysfunction in the regulation of portal hypertension
Iwakiri, Yasuko
2013-01-01
Portal hypertension is caused by an increased intrahepatic resistance, a major consequence of cirrhosis. Endothelial dysfunction in liver sinusoidal endothelial cells (LSECs) decreases the production of vasodilators, such as nitric oxide (NO) and favors vasoconstriction. This contributes to an increased vascular resistance in the intrahepatic/sinusoidal microcirculation. Portal hypertension, once developed, causes endothelial cell (EC) dysfunction in the extrahepatic, i.e. splanchnic and systemic, circulation. Unlike LSEC dysfunction, EC dysfunction in the splanchnic and systemic circulation overproduces vasodilator molecules, leading to arterial vasodilatation. In addition, portal hypertension leads to the formation of portosystemic collateral vessels. Both arterial vasodilatation and portosystemic collateral vessel formation exacerbate portal hypertension by increasing the blood flow through the portal vein. Pathologic consequences, such as esophageal varices and ascites, result. While the sequence of pathological vascular events in cirrhosis and portal hypertension have been elucidated, the underlying cellular and molecular mechanisms causing EC dysfunctions are not yet fully understood. This review article summarizes the current cellular and molecular studies on EC dysfunctions found during the development of cirrhosis and portal hypertension with a focus on intra- and extrahepatic circulation. The article ends by discussing future directions of study for EC dysfunctions. PMID:21745318
Mitigating the effects of landscape development on streams in urbanizing watersheds
Hogan, Dianna M.; Jarnagin, S. Taylor; Loperfido, John V.; Van Ness, Keith
2013-01-01
This collaborative study examined urbanization and impacts on area streams while using the best available sediment and erosion control (S&EC) practices in developing watersheds in Maryland, United States. During conversion of the agricultural and forested watersheds to urban land use, land surface topography was graded and vegetation was removed creating a high potential for sediment generation and release during storm events. The currently best available S&EC facilities were used during the development process to mitigate storm runoff water quality, quantity, and timing before entering area streams. Detailed Geographic Information System (GIS) maps were created to visualize changing land use and S&EC practices, five temporal collections of LiDAR (light detection and ranging) imagery were used to map the changing landscape topography, and streamflow, physical geomorphology, and habitat data were used to assess the ability of the S&EC facilities to protect receiving streams during development. Despite the use of the best available S&EC facilities, receiving streams experienced altered flow, geomorphology, and decreased biotic community health. These impacts on small streams during watershed development affect sediment and nutrient loads to larger downstream aquatic ecosystems such as the Chesapeake Bay.
Esophageal cancer stem cells and implications for future therapeutics.
Qian, Xia; Tan, Cheng; Wang, Feng; Yang, Baixia; Ge, Yangyang; Guan, Zhifeng; Cai, Jing
2016-01-01
Esophageal carcinoma (EC) is a lethal disease with high morbidity and mortality worldwide, and the incidence has been increasing in recent years. Although the diagnosis and treatment of EC have improved considerably, EC has rapidly progressed in the clinical setting and has a poor prognosis for its metastasis and recurrence. The general idea of cancer stem cells (CSCs) is primarily based on clinical and experimental observations, indicating the existence of a subpopulation of cells that can self-renew and differentiate. The EC stem cells, which can be isolated from normal pluripotent stem cells by applying similar biomarkers, may participate in promoting esophageal tumorigenesis through renewal and repair. In this review, major emphasis is given to CSC markers, altered CSC-specific pathways, and molecular targeting agents currently available to target CSCs of esophageal cancer. The roles of numerous markers (CD44, aldehyde dehydrogenase, CD133, and ATP-binding cassette subfamily G member 2) and developmental signaling pathways (Wnt/β-catenin, Notch, hedgehog, and Hippo) in isolating esophageal CSCs are discussed in detail. Targeting CSCs can be a logical strategy to treat EC, as these cells are responsible for carcinoma recurrence and chemoradiation resistance.
Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid
Byambasuren, Bat-erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar
2016-01-01
Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274
Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.
Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar
2016-02-19
Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.
Do Formal Inspections Ensure that British Zoos Meet and Improve on Minimum Animal Welfare Standards?
Draper, Chris; Browne, William; Harris, Stephen
2013-01-01
Simple Summary Key aims of the formal inspections of British zoos are to assess compliance with minimum standards of animal welfare and promote improvements in animal care and husbandry. We compared reports from two consecutive inspections of 136 British zoos to see whether these goals were being achieved. Most zoos did not meet all the minimum animal welfare standards and there was no clear evidence of improving levels of compliance with standards associated with the Zoo Licensing Act 1981. The current system of licensing and inspection does not ensure that British zoos meet and maintain, let alone exceed, the minimum animal welfare standards. Abstract We analysed two consecutive inspection reports for each of 136 British zoos made by government-appointed inspectors between 2005 and 2011 to assess how well British zoos were complying with minimum animal welfare standards; median interval between inspections was 1,107 days. There was no conclusive evidence for overall improvements in the levels of compliance by British zoos. Having the same zoo inspector at both inspections affected the outcome of an inspection; animal welfare criteria were more likely to be assessed as unchanged if the same inspector was present on both inspections. This, and erratic decisions as to whether a criterion applied to a particular zoo, suggest inconsistency in assessments between inspectors. Zoos that were members of a professional association (BIAZA) did not differ significantly from non-members in the overall number of criteria assessed as substandard at the second inspection but were more likely to meet the standards on both inspections and less likely to have criteria remaining substandard. Lack of consistency between inspectors, and the high proportion of zoos failing to meet minimum animal welfare standards nearly thirty years after the Zoo Licensing Act came into force, suggest that the current system of licensing and inspection is not meeting key objectives and requires revision. PMID:26479752
The EBIT Calorimeter Spectrometer: a new, permanent user facility at the LLNL EBIT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porter, F S; Beiersdorfer, P; Brown, G V
The EBIT Calorimeter Spectrometer (ECS) is currently being completed and will be installed at the EBIT facility at the Lawrence Livermore National Laboratory in October 2007. The ECS will replace the smaller XRS/EBIT microcalorimeter spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory program. The new ECS spectrometer was built to be a low maintenance, high performance implanted silicon microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 {micro}s event timing, and capable of uninterrupted acquisitionmore » sessions of over 60 hours at 50 mK. The XRS/EBIT program has been very successful, producing many results on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES instrument.« less
High-throughput identification of small molecules that affect human embryonic vascular development
Vazão, Helena; Rosa, Susana; Barata, Tânia; Costa, Ricardo; Pitrez, Patrícia R.; Honório, Inês; de Vries, Margreet R.; Papatsenko, Dimitri; Benedito, Rui; Saris, Daniel; Khademhosseini, Ali; Quax, Paul H. A.; Pereira, Carlos F.; Mercader, Nadia; Ferreira, Lino
2017-01-01
Birth defects, which are in part caused by exposure to environmental chemicals and pharmaceutical drugs, affect 1 in every 33 babies born in the United States each year. The current standard to screen drugs that affect embryonic development is based on prenatal animal testing; however, this approach yields low-throughput and limited mechanistic information regarding the biological pathways and potential adverse consequences in humans. To develop a screening platform for molecules that affect human embryonic development based on endothelial cells (ECs) derived from human pluripotent stem cells, we differentiated human pluripotent stem cells into embryonic ECs and induced their maturation under arterial flow conditions. These cells were then used to screen compounds that specifically affect embryonic vasculature. Using this platform, we have identified two compounds that have higher inhibitory effect in embryonic than postnatal ECs. One of them was fluphenazine (an antipsychotic), which inhibits calmodulin kinase II. The other compound was pyrrolopyrimidine (an antiinflammatory agent), which inhibits vascular endothelial growth factor receptor 2 (VEGFR2), decreases EC viability, induces an inflammatory response, and disrupts preformed vascular networks. The vascular effect of the pyrrolopyrimidine was further validated in prenatal vs. adult mouse ECs and in embryonic and adult zebrafish. We developed a platform based on human pluripotent stem cell-derived ECs for drug screening, which may open new avenues of research for the study and modulation of embryonic vasculature. PMID:28348206
Comprehensive Insights into the Reactivity of Electrolytes Based on Sodium Ions.
Eshetu, Gebrekidan Gebresilassie; Grugeon, Sylvie; Kim, Huikyong; Jeong, Sangsik; Wu, Liming; Gachot, Gregory; Laruelle, Stephane; Armand, Michel; Passerini, Stefano
2016-03-08
We report a systematic investigation of Na-based electrolytes that comprise various NaX [X=hexafluorophosphate (PF6 ), perchlorate (ClO4 ), bis(trifluoromethanesulfonyl)imide (TFSI), fluorosulfonyl-(trifluoromethanesulfonyl)imide (FTFSI), and bis(fluorosulfonyl)imide (FSI)] salts and solvent mixtures [ethylene carbonate (EC)/dimethyl carbonate (DMC), EC/diethyl carbonate (DEC), and EC/propylene carbonate (PC)] with respect to the Al current collector stability, formation of soluble degradation compounds, reactivity towards sodiated hard carbon (Nax -HC), and solid-electrolyte interphase (SEI) layer formation. Cyclic voltammetry demonstrates that the stability of Al is highly influenced by the nature of the anions, solvents, and additives. GC-MS analysis reveals that the formation of SEI telltales depends on the nature of the linear alkyl carbonates and the battery chemistry (Li(+) vs. Na(+) ). FTIR spectroscopy shows that double alkyl carbonates are the main components of the SEI layer on Nax -HC. In the presence of Na salts, EC/DMC and EC/DEC presented a higher reactivity towards Nax -HC than EC/PC. For a fixed solvent mixture, the onset temperature follows the sequence NaClO4
High-throughput identification of small molecules that affect human embryonic vascular development.
Vazão, Helena; Rosa, Susana; Barata, Tânia; Costa, Ricardo; Pitrez, Patrícia R; Honório, Inês; de Vries, Margreet R; Papatsenko, Dimitri; Benedito, Rui; Saris, Daniel; Khademhosseini, Ali; Quax, Paul H A; Pereira, Carlos F; Mercader, Nadia; Fernandes, Hugo; Ferreira, Lino
2017-04-11
Birth defects, which are in part caused by exposure to environmental chemicals and pharmaceutical drugs, affect 1 in every 33 babies born in the United States each year. The current standard to screen drugs that affect embryonic development is based on prenatal animal testing; however, this approach yields low-throughput and limited mechanistic information regarding the biological pathways and potential adverse consequences in humans. To develop a screening platform for molecules that affect human embryonic development based on endothelial cells (ECs) derived from human pluripotent stem cells, we differentiated human pluripotent stem cells into embryonic ECs and induced their maturation under arterial flow conditions. These cells were then used to screen compounds that specifically affect embryonic vasculature. Using this platform, we have identified two compounds that have higher inhibitory effect in embryonic than postnatal ECs. One of them was fluphenazine (an antipsychotic), which inhibits calmodulin kinase II. The other compound was pyrrolopyrimidine (an antiinflammatory agent), which inhibits vascular endothelial growth factor receptor 2 (VEGFR2), decreases EC viability, induces an inflammatory response, and disrupts preformed vascular networks. The vascular effect of the pyrrolopyrimidine was further validated in prenatal vs. adult mouse ECs and in embryonic and adult zebrafish. We developed a platform based on human pluripotent stem cell-derived ECs for drug screening, which may open new avenues of research for the study and modulation of embryonic vasculature.
Thermally stimulated capacitance in gamma irradiated epitaxial 4H-SiC Schottky barrier diodes
NASA Astrophysics Data System (ADS)
Vigneshwara Raja, P.; Narasimha Murty, N. V. L.
2018-04-01
Deep level defects in 4H-SiC Schottky barrier diodes (SBDs) fabricated on n-type epitaxial 4H-SiC have been identified by thermally stimulated capacitance (TSCAP) spectroscopy prior to and after 60Co-gamma irradiation. The TSCAP measurements on the non-irradiated SBDs reveal two electron traps at Ec-0.63 eV (˜250 K) and Ec-1.13 eV (˜525 K), whereas only one trap at Ec-0.63 eV is identified by conventional thermally stimulated current (TSC) measurements. Hence, TSCAP spectroscopy is more effective in identifying deep level defects in epitaxial 4 H-SiC SBDs as compared to the TSC spectroscopy. Upon exposure to 60Co-gamma rays up to a dose of 100 Mrad, significant changes in the concentration of the traps at Ec-0.63 eV, Ec-1.13 eV, and one new trap at Ec-0.89 eV (˜420 K) are observed. The electrical characteristics of the SBDs are considerably changed after gamma irradiation. The dominant mechanisms responsible for the irradiation induced changes in the SBD electrical characteristics are analyzed by incorporating the trap signatures in the commercial Silvaco® TCAD device simulator. The extracted trap parameters of the irradiated SBDs may be helpful in predicting the survival of 4H-SiC SBD detectors at higher irradiation levels.
Evolution of the Ultrasonic Inspection Requirements of Heavy Rotor Forgings Over the Past Decades
NASA Astrophysics Data System (ADS)
Vrana, J.; Zimmer, A.; Bailey, K.; Angal, R.; Zombo, P.; Büchner, U.; Buschmann, A.; Shannon, R. E.; Lohmann, H.-P.; Heinrich, W.
2010-02-01
Heavy rotor forgings for land-based power generation turbines and generators are inspected ultrasonically. Several decades ago the first inspections were conducted using manual, straight beam, contact transducers with simple, non-descript reporting requirements. The development of ultrasonic inspection capabilities, the change in design engineer requirements, improvements of fracture mechanics calculations, experience with turbine operation, experience with the inspection technology, and probability of detection drove the changes that have resulted in the current day inspection requirements: sizing technologies were implemented, detection limits were lowered, angle and pitch/catch (dual crystal) scans were introduced, and most recently automated equipment for the inspection was required. Due to all these changes, model based sizing techniques, like DGS, and modern ultrasonic techniques, like phased array, are being introduced globally. This paper describes the evolution of the ultrasonic inspection requirements over the last decades and presents an outlook for tomorrow.
Simulation of tropospheric chemistry and aerosols with the climate model EC-Earth
NASA Astrophysics Data System (ADS)
van Noije, T. P. C.; Le Sager, P.; Segers, A. J.; van Velthoven, P. F. J.; Krol, M. C.; Hazeleger, W.; Williams, A. G.; Chambers, S. D.
2014-10-01
We have integrated the atmospheric chemistry and transport model TM5 into the global climate model EC-Earth version 2.4. We present an overview of the TM5 model and the two-way data exchange between TM5 and the IFS model from the European Centre for Medium-Range Weather Forecasts (ECMWF), the atmospheric general circulation model of EC-Earth. In this paper we evaluate the simulation of tropospheric chemistry and aerosols in a one-way coupled configuration. We have carried out a decadal simulation for present-day conditions and calculated chemical budgets and climatologies of tracer concentrations and aerosol optical depth. For comparison we have also performed offline simulations driven by meteorological fields from ECMWF's ERA-Interim reanalysis and output from the EC-Earth model itself. Compared to the offline simulations, the online-coupled system produces more efficient vertical mixing in the troposphere, which reflects an improvement of the treatment of cumulus convection. The chemistry in the EC-Earth simulations is affected by the fact that the current version of EC-Earth produces a cold bias with too dry air in large parts of the troposphere. Compared to the ERA-Interim driven simulation, the oxidizing capacity in EC-Earth is lower in the tropics and higher in the extratropics. The atmospheric lifetime of methane in EC-Earth is 9.4 years, which is 7% longer than the lifetime obtained with ERA-Interim but remains well within the range reported in the literature. We further evaluate the model by comparing the simulated climatologies of surface radon-222 and carbon monoxide, tropospheric and surface ozone, and aerosol optical depth against observational data. The work presented in this study is the first step in the development of EC-Earth into an Earth system model with fully interactive atmospheric chemistry and aerosols.
Bellone, Stefania; Eliana, Bignotti; Lonardi, Silvia; Ferrari, Francesca; Centritto, Floriana; Masserdotti, Alice; Pettinella, Francesca; Black, Jonathan; Menderes, Gulden; Altwerger, Gary; Hui, Pei; Lopez, Salvatore; de Haydu, Christopher; Bonazzoli, Elena; Predolini, Federica; Zammataro, Luca; Cocco, Emiliano; Ferrari, Federico; Ravaggi, Antonella; Romani, Chiara; Facchettie, Fabio; Sartori, Enrico; Odicino, Franco E.; Silasi, Dan-Arin; Litkouhi, Babak; Ratner, Elena; Azodi, Masoud; Schwartz, Peter E.; Santin, Alessandro D.
2016-01-01
Objective Up to 12 % of all endometrial-carcinomas (EC) harbor DNA-polymerase-ε-(POLE) mutations. It is currently unknown whether the favorable prognosis of POLE-mutated EC is derived from their low metastatic capability, extraordinary number of somatic mutations thus imparting immunogenicity, or a high sensitivity to chemotherapy. Methods Polymerase-chain-reaction-amplification and Sanger-sequencing were used to test for POLE exonuclease-domain-mutations (exons 9–14) 131 EC. Infiltration of CD4+ and CD8+ T-lymphocytes (TIL) and PD-1-expression in POLE-mutated vs POLE wild-type EC was studied by immunohistochemistry (IHC) and the correlations between survival and molecular features were investigated. Finally, primary POLE-mutated and POLE-wild-type EC cell lines were established and compared in-vitro for their sensitivity to chemotherapy. Results Eleven POLE-mutated EC (8.5%) were identified. POLE-mutated tumors were associated with improved progression-free-survival (P<0.05) and displayed increased numbers of CD4+ (44.5 vs 21.8; P = .001) and CD8+ (32.8 vs 13.5; P < .001) TILs when compared to wild-type POLE EC. PD-1 receptor was overexpressed in TILs from POLE-mutated vs wild-type-tumors (81% vs 28%; P < .001). Primary POLE tumor cell lines were significantly more resistant to platinum-chemotherapy in-vitro when compared to POLE-wild-type tumors (P < 0.004). Conclusions POLE ultra-mutated EC are heavily infiltrated with CD4+/CD8+ TIL, overexpress PD-1 immune-check-point (i.e., features consistent with chronic antigen-exposure), and have a better prognosis when compared to other molecular subtypes of EC patients. POLE-mutated tumor-cell lines are resistant to platinum-chemotherapy in-vitro suggesting that the better prognosis of POLE-patients is not secondary to a higher sensitivity to chemotherapy but likely linked to enhanced immunogenicity. PMID:27894751
NASA Astrophysics Data System (ADS)
Zhou, Fengxia; Gao, Xuelu; Song, Jinming; Chen, Chen-Tung Arthur; Yuan, Huamao; Xing, Qianguo
2018-05-01
The absorption properties of chromophoric dissolved organic matter (CDOM) in the East China Sea (ECS) and the waters off eastern Taiwan (WET) were studied during May 2014. CDOM absorption coefficient (a280) and spectral slope (S275-295) revealed considerable spatial variations. In the ECS, the values of a280 and S275-295 presented a reverse distribution pattern. In the WET, a280 values were generally low while S275-295 values were generally high. Vertical distributions of a280 and S275-295 also varied in different regions. Terrestrial input, phytoplankton production, sediment release or photobleaching may be responsible for the dynamics of CDOM. Relationships among CDOM related parameters could partly support this conclusion. a280 were also used to trace different water masses and the result showed that the influence of Changjiang Diluted Water could reach the outer shelf of the northern ECS, and that the Kuroshio Current had a strong influence on the middle shelf of the southern ECS.
Testing Women With Endometrial Cancer for Lynch Syndrome: Should We Test All?
Ma, Jun; Ledbetter, Nancy; Glenn, Lyn
2013-01-01
Women with Lynch syndrome (LS) are at equal or higher risk for gynecologic cancers compared with their risk for colorectal cancer (CRC). Endometrial cancer (EC) often precedes CRC as patients’ sentinel malignancy. Identifying these patients is believed to reduce their substantial risk for synchronous and metachronous tumors and has profound implications for reducing cancer-related morbidity and mortality in other family members. Routine screening of patients with CRC for LS has become increasingly common, but routine screening for LS in women with EC is rarely performed. Current screening guidelines for identifying LS in women with EC vary but rely heavily on patient age and personal/family history, with or without incorporation of tumor pathology. Because each of these strategies misses a significant proportion of women with LS, more inclusive screening strategies that make good economic and clinical sense are needed. In recent years, emerging medicoeconomic evidence supports the fact that screening EC patients for LS may be cost-effective. Implementation of such a strategy requires multidisciplinary collaboration and partnership. PMID:25032011
Aerosol-jet-printed, 1 volt H-bridge drive circuit on plastic with integrated electrochromic pixel.
Ha, Mingjing; Zhang, Wei; Braga, Daniele; Renn, Michael J; Kim, Chris H; Frisbie, C Daniel
2013-12-26
In this report, we demonstrate a printed, flexible, and low-voltage circuit that successfully drives a polymer electrochromic (EC) pixel as large as 4 mm(2) that is printed on the same substrate. All of the key components of the drive circuitry, namely, resistors, capacitors, and transistors, were aerosol-jet-printed onto a plastic foil; metallic electrodes and interconnects were the only components prepatterned on the plastic by conventional photolithography. The large milliampere drive currents necessary to switch a 4 mm(2) EC pixel were controlled by printed electrolyte-gated transistors (EGTs) that incorporate printable ion gels for the gate insulator layers and poly(3-hexylthiophene) for the semiconductor channels. Upon application of a 1 V input pulse, the circuit switches the printed EC pixel ON (red) and OFF (blue) two times in approximately 4 s. The performance of the circuit and the behavior of the individual resistors, capacitors, EGTs, and the EC pixel are analyzed as functions of the printing parameters and operating conditions.
Huang, Ching-Yu; Cheah, Charissa S. L.; Lamb, Michael E.; Zhou, Nan
2017-01-01
The current study examined the associations between parentally perceived child effortful control (EC) and the parenting styles of 122 Chinese mothers (36 first-generation Chinese immigrants in the United Kingdom, 40 first-generation Chinese immigrants in the United States, and 46 Taiwanese mothers) of 5- to 7-year-old (M age = 5.82 years, SD = .805; 68 boys and 54 girls) children. The findings showed significant cultural group differences in mothers’ reported authoritarian parenting style. Significant associations also emerged between mothers’ reports of their children’s EC and some parenting dimensions, although there were no cultural group differences in perceived child EC. Different patterns of associations between perceived child EC and parenting styles in these three groups also demonstrated heterogeneity within the Chinese population, and highlighted the need to consider differences between original and receiving societies when seeking to understand parenting and child development in different immigrant groups. PMID:29276309
Espinoza, María Inés; Vincken, Jean-Paul; Sanders, Mark; Castro, Cristian; Stieger, Markus; Agosin, Eduardo
2014-12-10
Stevia rebaudiana is known for its sweet-tasting ent-kaurene diterpenoid glycosides. Several manufacturing strategies are currently employed to obtain Stevia sweeteners with the lowest possible off-flavors. The chemical composition of four commercial S. rebaudiana extracts, obtained by different technologies, was characterized using UHPLC-ESI-MS(n). The composition of one of the ethanol-crystallized extracts (EC2) was entirely rebaudioside A, whereas the enzymatically modified (EM) extract contained the lowest concentration of this compound (2.7 mg/100 mg). The membrane-purified (MP) extract had the highest content of minor natural steviol glycosides (23.7 mg/100 mg total extract) versus an average of 2.4 mg/100 mg total extract for the EC samples. Thirteen trained panelists evaluated sweetness, bitterness, licorice, and metallic attributes of all four extracts. The highest licorice intensity (p ≤ 0.05) was found for MP. Both samples EC1 and EC2, despite their different chemical compositions, showed no significant differences in sensory perception.
Huang, Ching-Yu; Cheah, Charissa S L; Lamb, Michael E; Zhou, Nan
2017-07-01
The current study examined the associations between parentally perceived child effortful control (EC) and the parenting styles of 122 Chinese mothers (36 first-generation Chinese immigrants in the United Kingdom, 40 first-generation Chinese immigrants in the United States, and 46 Taiwanese mothers) of 5- to 7-year-old ( M age = 5.82 years, SD = .805; 68 boys and 54 girls) children. The findings showed significant cultural group differences in mothers' reported authoritarian parenting style. Significant associations also emerged between mothers' reports of their children's EC and some parenting dimensions, although there were no cultural group differences in perceived child EC. Different patterns of associations between perceived child EC and parenting styles in these three groups also demonstrated heterogeneity within the Chinese population, and highlighted the need to consider differences between original and receiving societies when seeking to understand parenting and child development in different immigrant groups.
NASA Astrophysics Data System (ADS)
Qiang, Lei; Liang, Xiaoci; Cai, Guangshuo; Pei, Yanli; Yao, Ruohe; Wang, Gang
2018-06-01
Indium zinc oxide (IZO) thin film transistor (TFT) deposited by solution method is of considerable technological interest as it is a key component for the fabrication of flexible and cheap transparent electronic devices. To obtain a principal understanding of physical properties of solution-processed IZO TFT, a new drain current model that account for the charge transport is proposed. The formulation is developed by incorporating the effect of gate voltage on mobility and threshold voltage with the carrier charges. It is demonstrated that in IZO TFTs the below threshold regime should be divided into two sections: EC - EF > 3kT and EC - EF ≤ 3kT, where kT is the thermal energy, EF and EC represent the Fermi level and the conduction band edge, respectively. Additionally, in order to describe conduction mechanisms more accurately, the extended mobility edge model is conjoined, which can also get rid of the complicated and lengthy computations. The good agreement between measured and calculated results confirms the efficiency of this model for the design of integrated large-area thin film circuits.
Kim, Han-Lae; Cho, Jong-Bok; Park, Yong-Jin; Cho, Il-Hyoung
2016-07-02
A pilot-scale study was conducted using the electrocoagulation-electroflotation (EC-EF) process to treat textile dyeing raw wastewater to evaluate treatment performance. The effects of some key factors, such as current density, hydraulic retention time (HRT), and removal of conductivity, total suspended solids (TSS), chemical oxygen demand (COD), and color were investigated. The operating variables were current density of 0-300 A m(-2), HRT of 0-30 min, and a coagulant (anionic polyacrylamide (A-PAM)) dosage of 0-30 mg L(-1). Daphnia magna was used to test acute toxicity in raw and treated wastewater. Under the operating conditions without added coagulant, maxima of 51%, 88%, 84%, and 99% of conductivity, TSS, COD, and color were removed, respectively, with a HRT of 30 min. The coagulant enhanced removal of all wastewater parameters. Removal maxima of 59%, 92%, 94%, and 98% for conductivity, TSS, COD, and color were observed, respectively, with an optimal dosage of 30 mg L(-1) and a shortened HRT of 20 min. The 48 h-LC50 D. magna test showed that the raw wastewater was highly toxic. However, the EC-EF process decreased toxicity of the treated samples significantly, and >70% toxicity reduction was achieved by the EC-EF process with the addition of 15-30 mg L(-1) coagulant, HRT of 20 min, and current density of 150-300 A m(-2). The pilot scale test (0.3 m(3 )h(-1)) shows that the EC-EF process with added coagulant effectively treated textile dyeing wastewater.
Effect of thiopental sodium on N-methyl-D-aspartate-gated currents.
Liu, Hongliang; Dai, Tijun; Yao, Shanglong
2006-05-01
N-methyl-D-aspartate (NMDA) receptors in the prefrontal cortex (PFC) are closely related with the excitability of pyramidal neurons and PFC function. As the effect of thiopental sodium on the central nervous system may partly result from the inhibition of PFC NMDA receptors, we investigated the effect of thiopental sodium with different concentrations on NMDA-gated currents in acutely dissociated rat PFC pyramidal neurons. We sought to determine whether thiopental sodium inhibits NMDA receptor function. Three to four week old male Sprague-Dawley rats were sacrificed and the PFC was dissected. Pyramidal neurons from the PFC were prepared and standard whole-cell patch clamp recordings were performed. Escalating concentrations from 3-1000 microM NMDA were applied 100 microm from the pyramidal cells, and the concentration in the effect compartment related to 50% effect (EC50) of NMDA was determined for the ensuing experiments. One hundred microM NMDA alone (control) or NMDA with different concentrations (10-1000 microM) of thiopental sodium were applied. After the inhibitory concentration, in 50% of NMDA effect (IC50) of thiopental sodium was established this IC50 and NMDA 3-1000 microM were applied 100 microm from the pyramidal cells. The EC50 value of NMDA under the effect of IC50 thiopental sodium was determined. N-methyl-D-aspartate induced inward currents in a concentration-dependent manner, which were completely antagonized by 50 microM AP5. The maximal amplitude of NMDA-induced current was 1.15 +/- 0.27 nA. The EC50 of NMDA was 53.6 +/- 12.4 microM. The NMDA (100 microM)-gated current was inhibited by thiopental sodium in a concentration-dependent manner, and the IC50 of thiopental sodium was 33.6 +/- 6.1 microM. Under the effect of 33.6 microM thiopental sodium, the maximal amplitude of NMDA-induced current was 0.87 +/- 0.17 nA. The concentration-response curve of NMDA was shifted rightwards. The EC50 of NMDA was 128 +/- 15 microM, which was greater than that of NMDA without thiopental sodium (P < 0.01). Thiopental sodium decreases NMDA-gated currents in acutely dissociated rat prefrontal cortical pyramidal neurons in a concentration-dependent manner.
Addressing Water Consumption of Evaporative Coolers with Greywater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sahai, Rashmi; Shah, Nihar; Phadke, Amol
Evaporative coolers (ECs) provide significant gains in energy efficiency compared to vapor compression air conditioners, but simultaneously have significant onsite water demand. This can be a major barrier to deployment in areas of the world with hot and arid climates. To address this concern, this study determined where in the world evaporative cooling is suitable, the water consumption of ECs in these cities, and the potential that greywater can be used reduce the consumption of potable water in ECs. ECs covered 69percent of the cities where room air conditioners are may be deployed, based on comfort conditions alone. The averagemore » water consumption due to ECs was found to be 400 L/household/day in the United States and Australia, with the potential for greywater to provide 50percent this amount. In the rest of the world, the average water consumption was 250 L/household/day, with the potential for greywater to supply 80percent of this amount. Home size was the main factor that contributed to this difference. In the Mediterranean, the Middle East, Northern India, and the Midwestern and Southwestern United States alkalinity levels are high and water used for bleeding will likely contribute significantly to EC water consumption. Although technically feasible, upfront costs for household GW systems are currently high. In both developed and developing parts of the world, however, a direct EC and GW system is cost competitive with conventional vapor compression air conditioners. Moreover, in regions of the world that face problems of water scarcity the benefits can substantially outweigh the costs.« less
Evaluating Emergent Constraints for Equilibrium Climate Sensitivity
Caldwell, Peter M.; Zelinka, Mark D.; Klein, Stephen A.
2018-04-23
Emergent constraints are quantities that are observable from current measurements and have skill predicting future climate. Here, this study explores 19 previously proposed emergent constraints related to equilibrium climate sensitivity (ECS; the global-average equilibrium surface temperature response to CO 2 doubling). Several constraints are shown to be closely related, emphasizing the importance for careful understanding of proposed constraints. A new method is presented for decomposing correlation between an emergent constraint and ECS into terms related to physical processes and geographical regions. Using this decomposition, one can determine whether the processes and regions explaining correlation with ECS correspond to the physicalmore » explanation offered for the constraint. Shortwave cloud feedback is generally found to be the dominant contributor to correlations with ECS because it is the largest source of intermodel spread in ECS. In all cases, correlation results from interaction between a variety of terms, reflecting the complex nature of ECS and the fact that feedback terms and forcing are themselves correlated with each other. For 4 of the 19 constraints, the originally proposed explanation for correlation is borne out by our analysis. These four constraints all predict relatively high climate sensitivity. The credibility of six other constraints is called into question owing to correlation with ECS coming mainly from unexpected sources and/or lack of robustness to changes in ensembles. Another six constraints lack a testable explanation and hence cannot be confirmed. Lastly, the fact that this study casts doubt upon more constraints than it confirms highlights the need for caution when identifying emergent constraints from small ensembles.« less
An active learning approach for rapid characterization of endothelial cells in human tumors.
Padmanabhan, Raghav K; Somasundar, Vinay H; Griffith, Sandra D; Zhu, Jianliang; Samoyedny, Drew; Tan, Kay See; Hu, Jiahao; Liao, Xuejun; Carin, Lawrence; Yoon, Sam S; Flaherty, Keith T; Dipaola, Robert S; Heitjan, Daniel F; Lal, Priti; Feldman, Michael D; Roysam, Badrinath; Lee, William M F
2014-01-01
Currently, no available pathological or molecular measures of tumor angiogenesis predict response to antiangiogenic therapies used in clinical practice. Recognizing that tumor endothelial cells (EC) and EC activation and survival signaling are the direct targets of these therapies, we sought to develop an automated platform for quantifying activity of critical signaling pathways and other biological events in EC of patient tumors by histopathology. Computer image analysis of EC in highly heterogeneous human tumors by a statistical classifier trained using examples selected by human experts performed poorly due to subjectivity and selection bias. We hypothesized that the analysis can be optimized by a more active process to aid experts in identifying informative training examples. To test this hypothesis, we incorporated a novel active learning (AL) algorithm into FARSIGHT image analysis software that aids the expert by seeking out informative examples for the operator to label. The resulting FARSIGHT-AL system identified EC with specificity and sensitivity consistently greater than 0.9 and outperformed traditional supervised classification algorithms. The system modeled individual operator preferences and generated reproducible results. Using the results of EC classification, we also quantified proliferation (Ki67) and activity in important signal transduction pathways (MAP kinase, STAT3) in immunostained human clear cell renal cell carcinoma and other tumors. FARSIGHT-AL enables characterization of EC in conventionally preserved human tumors in a more automated process suitable for testing and validating in clinical trials. The results of our study support a unique opportunity for quantifying angiogenesis in a manner that can now be tested for its ability to identify novel predictive and response biomarkers.
Evaluating Emergent Constraints for Equilibrium Climate Sensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caldwell, Peter M.; Zelinka, Mark D.; Klein, Stephen A.
Emergent constraints are quantities that are observable from current measurements and have skill predicting future climate. Here, this study explores 19 previously proposed emergent constraints related to equilibrium climate sensitivity (ECS; the global-average equilibrium surface temperature response to CO 2 doubling). Several constraints are shown to be closely related, emphasizing the importance for careful understanding of proposed constraints. A new method is presented for decomposing correlation between an emergent constraint and ECS into terms related to physical processes and geographical regions. Using this decomposition, one can determine whether the processes and regions explaining correlation with ECS correspond to the physicalmore » explanation offered for the constraint. Shortwave cloud feedback is generally found to be the dominant contributor to correlations with ECS because it is the largest source of intermodel spread in ECS. In all cases, correlation results from interaction between a variety of terms, reflecting the complex nature of ECS and the fact that feedback terms and forcing are themselves correlated with each other. For 4 of the 19 constraints, the originally proposed explanation for correlation is borne out by our analysis. These four constraints all predict relatively high climate sensitivity. The credibility of six other constraints is called into question owing to correlation with ECS coming mainly from unexpected sources and/or lack of robustness to changes in ensembles. Another six constraints lack a testable explanation and hence cannot be confirmed. Lastly, the fact that this study casts doubt upon more constraints than it confirms highlights the need for caution when identifying emergent constraints from small ensembles.« less
Solar absorption by elemental and brown carbon determined from spectral observations.
Bahadur, Ranjit; Praveen, Puppala S; Xu, Yangyang; Ramanathan, V
2012-10-23
Black carbon (BC) is functionally defined as the absorbing component of atmospheric total carbonaceous aerosols (TC) and is typically dominated by soot-like elemental carbon (EC). However, organic carbon (OC) has also been shown to absorb strongly at visible to UV wavelengths and the absorbing organics are referred to as brown carbon (BrC), which is typically not represented in climate models. We propose an observationally based analytical method for rigorously partitioning measured absorption aerosol optical depths (AAOD) and single scattering albedo (SSA) among EC and BrC, using multiwavelength measurements of total (EC, OC, and dust) absorption. EC is found to be strongly absorbing (SSA of 0.38) whereas the BrC SSA varies globally between 0.77 and 0.85. The method is applied to the California region. We find TC (EC + BrC) contributes 81% of the total absorption at 675 nm and 84% at 440 nm. The BrC absorption at 440 nm is about 40% of the EC, whereas at 675 nm it is less than 10% of EC. We find an enhanced absorption due to OC in the summer months and in southern California (related to forest fires and secondary OC). The fractions and trends are broadly consistent with aerosol chemical-transport models as well as with regional emission inventories, implying that we have obtained a representative estimate for BrC absorption. The results demonstrate that current climate models that treat OC as nonabsorbing are underestimating the total warming effect of carbonaceous aerosols by neglecting part of the atmospheric heating, particularly over biomass-burning regions that emit BrC.
77 FR 31762 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
..., Steel Part Surface Inspection (Impedance Plane Display), of Part 6, Eddy Current, of the Boeing 707, 720... Subject 51-00-00 Figure 24, Steel Part Surface Inspection (Impedance Plane Display), of Part 6, Eddy...
150-nm DR contact holes die-to-database inspection
NASA Astrophysics Data System (ADS)
Kuo, Shen C.; Wu, Clare; Eran, Yair; Staud, Wolfgang; Hemar, Shirley; Lindman, Ofer
2000-07-01
Using a failure analysis-driven yield enhancements concept, based on an optimization of the mask manufacturing process and UV reticle inspection is studied and shown to improve the contact layer quality. This is achieved by relating various manufacturing processes to very fine tuned contact defect detection. In this way, selecting an optimized manufacturing process with fine-tuned inspection setup is achieved in a controlled manner. This paper presents a study, performed on a specially designed test reticle, which simulates production contact layers of design rule 250nm, 180nm and 150nm. This paper focuses on the use of advanced UV reticle inspection techniques as part of the process optimization cycle. Current inspection equipment uses traditional and insufficient methods of small contact-hole inspection and review.
Non-destructive inspection using HTS SQUID on aluminum liner covered by CFRP
NASA Astrophysics Data System (ADS)
Hatsukade, Y.; Yotsugi, K.; Sakaguchi, Y.; Tanaka, S.
2007-10-01
An eddy-current-based SQUID non-destructive inspection (NDI) system to detect deep-lying cracks in multi-layer composite-Al vessels was developed taking advantage of the uncontested sensitivity of HTS-SQUID in low-frequency range. An HTS-SQUID gradiometer was mounted in a pulse tube cryocooler. A pair of differential coils with C-shaped ferrite cores was employed to induce an enhanced eddy current in an Al vessel wrapped in a carbon fiber reinforced plastic (CFRP) cover. Ellipsoidal dome-shaped Al liners containing through cracks, which were made by pressure cycle tests, in the CFRP covers with total thickness of 6 mm (CFPR 3 mm, and Al 3 mm) were inspected by the system. While inducing eddy currents in the vessels with excitation fields at 100 Hz or 7 kHz, the vessels were rotated under the HTS-SQUID. Above the cracks, anomalous signals due to the cracks were clearly detected at both frequencies. These results suggested the SQUID-NDI technique would be a possible candidate for inspection of high-pressure multi-layer composite-Al vessels.
Characterization and optimization of spiral eddy current coils for in-situ crack detection
NASA Astrophysics Data System (ADS)
Mandache, Catalin
2018-03-01
In-situ condition-based maintenance is making strides in the aerospace industry and it is seen as an alternative to scheduled, time-based maintenance. With fatigue cracks originating from fastener holes as the main reason for structural failures, embedded eddy current coils are a viable non-invasive solution for their timely detection. The development and potential broad use of these coils are motivated by a few consistent arguments: (i) inspection of structures of complicated geometries and hard to access areas, that often require disassembly, (ii) alternative to regular inspection actions that could introduce inadvertent damage, (iii) for structures that have short inspection intervals, and (iv) for repaired structures where fastener holes contain bushings and prevent further bolt-hole inspections. Since the spiral coils are aiming at detecting radial cracks emanating from the fastener holes, their design parameters should allow for high inductance, low ohmic losses and power requirements, as well as optimal size and high sensitivity to discontinuities. In this study, flexible, surface conformable, spiral eddy current coils are empirically investigated on mock-up specimens, while numerical analysis is performed for their optimization and design improvement.
Automated eddy current analysis of materials
NASA Technical Reports Server (NTRS)
Workman, Gary L.
1991-01-01
The use of eddy current techniques for characterizing flaws in graphite-based filament-wound cylindrical structures is described. A major emphasis was also placed upon incorporating artificial intelligence techniques into the signal analysis portion of the inspection process. Developing an eddy current scanning system using a commercial robot for inspecting graphite structures (and others) was a goal in the overall concept and is essential for the final implementation for the expert systems interpretation. Manual scans, as performed in the preliminary work here, do not provide sufficiently reproducible eddy current signatures to be easily built into a real time expert system. The expert systems approach to eddy current signal analysis requires that a suitable knowledge base exist in which correct decisions as to the nature of a flaw can be performed. A robotic workcell using eddy current transducers for the inspection of carbon filament materials with improved sensitivity was developed. Improved coupling efficiencies achieved with the E-probes and horseshoe probes are exceptional for graphite fibers. The eddy current supervisory system and expert system was partially developed on a MacIvory system. Continued utilization of finite element models for predetermining eddy current signals was shown to be useful in this work, both for understanding how electromagnetic fields interact with graphite fibers, and also for use in determining how to develop the knowledge base. Sufficient data was taken to indicate that the E-probe and the horseshoe probe can be useful eddy current transducers for inspecting graphite fiber components. The lacking component at this time is a large enough probe to have sensitivity in both the far and near field of a thick graphite epoxy component.
Apparatus for inspecting piping
Zollingger, W. Thor; Appel, D. Keith; Park, Larry R.
1995-01-01
An inspection rabbit for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON.RTM.). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system.
Tackling the x-ray cargo inspection challenge using machine learning
NASA Astrophysics Data System (ADS)
Jaccard, Nicolas; Rogers, Thomas W.; Morton, Edward J.; Griffin, Lewis D.
2016-05-01
The current infrastructure for non-intrusive inspection of cargo containers cannot accommodate exploding com-merce volumes and increasingly stringent regulations. There is a pressing need to develop methods to automate parts of the inspection workflow, enabling expert operators to focus on a manageable number of high-risk images. To tackle this challenge, we developed a modular framework for automated X-ray cargo image inspection. Employing state-of-the-art machine learning approaches, including deep learning, we demonstrate high performance for empty container verification and specific threat detection. This work constitutes a significant step towards the partial automation of X-ray cargo image inspection.
Nafteux, Philippe; Lerut, Toni; De Hertogh, Gert; Moons, Johnny; Coosemans, Willy; Decker, Georges; Van Veer, Hans; De Leyn, Paul
2014-06-01
The current (7th) International Union Against Cancer (UICC) pN staging system is based on the number of positive lymph nodes but does not take into consideration the characteristics of the metastatic lymph nodes itself. In particular, it has been suggested that tumour penetration beyond the lymph node capsule in metastatic lymph nodes, which is also called extracapsular lymph node involvement, has a prognostic impact. The aim of the current study was to assess the prognostic value of extracapsular (EC) and intracapsular (IC) lymph node involvement (LNI) in adenocarcinoma of the oesophagus and gastro-oesophageal junction (GOJ) and to assess its potential impact on the 7th edition of the UICC TNM manual. From 2000 to 2010, all consecutive adenocarcinoma patients with primary R0-resection (n = 499) were prospectively included for analysis. The number of resected lymph nodes, number of positive lymph nodes and number of EC-LNI/IC-LNI were determined. Extracapsular spread was defined as infiltration of cancer cells beyond the capsule of the positive lymph node. Two hundred and eighteen (43%) patients had positive lymph nodes. Cancer-specific 5-year survival in lymph node-positive patients was significantly (P < 0.0001) worse compared with lymph node-negative patients, being 88.3 vs 28.7%, respectively. In 128 (58.7%) cases EC-LNI was detected. EC-LNI showed significantly worse cancer-specific 5-year survival compared with IC-LNI, 19.6 vs 44.0% (P < 0.0001). In the pN1 category (1 or 2 positive LN's-UICC stages IIB and IIIA), this was 30.4% vs 58%; (P = 0.029). In higher pN categories, this effect was no longer noticed. Integrating these findings into an adapted TNM classification resulted in improved homogeneity, monotonicity of gradients and discriminatory ability indicating an improved performance of the staging system. EC-LNI is associated with worse survival compared with IC-LNI. EC-LNI patients show survival rates that are more closely associated with the current TNM stage IIIB, while IC-LNI patients have a survival more similar to TNM stage IIB. Incorporating the EC-IC factor in the TNM classification results in an increased performance of the TNM model. Further confirmation from other centres is required within the context of future adaptations of the UICC/AJCC (American Joint Committee on Cancer) staging system for oesophageal cancer. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Comparing the sensitivity of chlorophytes, cyanobacteria, and diatoms to major-use antibiotics.
Guo, Jiahua; Selby, Katherine; Boxall, Alistair B A
2016-10-01
The occurrence of antibiotic residues in the aquatic environment is an emerging concern. In contrast to daphnia and fish, algae are known to be particularly sensitive to antibiotic exposure. However, to date, a systematic evaluation of the sensitivity of different algal species to antibiotics has not been performed. The aim of the present study was therefore to explore the sensitivity of a battery of algal species toward antibiotic exposures. The present study investigated the growth inhibition effects of 3 major-use antibiotics, tylosin, lincomycin, and trimethoprim, on 7 algal species from the chlorophyte, cyanobacteria, and diatom groups. Based on median effective concentration (EC50) values, cyanobacteria (EC50 = 0.095-0.13 μmol/L) were found to be the most sensitive group to lincomycin followed by chlorophytes (EC50 = 7.36-225.73 μmol/L) and diatoms (EC50 > 225.73 μmol/L). Cyanobacteria were also the most sensitive group to tylosin (EC50 = 0.09-0.092 μmol/L), but, for this compound, diatoms (EC50 = 1.33-5.7 μmol/L) were more sensitive than chlorophytes (EC50 = 4.14-81.2 μmol/L). Diatoms were most sensitive to trimethoprim (EC50 = 7.36-74.61 μmol/L), followed by cyanobacteria (EC50 = 315.78-344.45 μmol/L), and chlorophytes (EC50 > 344.45 μmol/L) for trimethoprim. Although these results partly support the current approach to regulatory environmental risk assessment (whereby cyanobacterial species are recommended for use with antibiotic compounds), they indicate that for some antibiotics this group might not be the most appropriate test organism. It is therefore suggested that environmental risk assessments consider data on 3 algal groups (chlorophytes, cyanobacteria, and diatoms) and use test species from these groups, which are consistently found to be the most sensitive (Pseudokirchneriella subcapitata, Anabaena flos-aquae, and Navicula pelliculosa). Environ Toxicol Chem 2016;35:2587-2596. © 2016 SETAC. © 2016 SETAC.
Increasing Type 1 Poliovirus Capsid Stability by Thermal Selection
Adeyemi, Oluwapelumi O.; Nicol, Clare
2016-01-01
ABSTRACT Poliomyelitis is a highly infectious disease caused by poliovirus (PV). It can result in paralysis and may be fatal. Integrated global immunization programs using live-attenuated oral (OPV) and/or inactivated (IPV) PV vaccines have systematically reduced its spread and paved the way for eradication. Immunization will continue posteradication to ensure against reintroduction of the disease, but there are biosafety concerns for both OPV and IPV. They could be addressed by the production and use of virus-free virus-like particle (VLP) vaccines that mimic the “empty” capsids (ECs) normally produced in viral infection. Although ECs are antigenically indistinguishable from mature virus particles, they are less stable and readily convert into an alternative conformation unsuitable for vaccine purposes. Stabilized ECs, expressed recombinantly as VLPs, could be ideal candidate vaccines for a polio-free world. However, although genome-free PV ECs have been expressed as VLPs in a variety of systems, their inherent antigenic instability has proved a barrier to further development. In this study, we selected thermally stable ECs of type 1 PV (PV-1). The ECs are antigenically stable at temperatures above the conversion temperature of wild-type (wt) virions. We have identified mutations on the capsid surface and in internal networks that are responsible for EC stability. With reference to the capsid structure, we speculate on the roles of these residues in capsid stability and postulate that such stabilized VLPs could be used as novel vaccines. IMPORTANCE Poliomyelitis is a highly infectious disease caused by PV and is on the verge of eradication. There are biosafety concerns about reintroduction of the disease from current vaccines that require live virus for production. Recombinantly expressed virus-like particles (VLPs) could address these inherent problems. However, the genome-free capsids (ECs) of wt PV are unstable and readily change antigenicity to a form not suitable as a vaccine. Here, we demonstrate that the ECs of type 1 PV can be stabilized by selecting heat-resistant viruses. Our data show that some capsid mutations stabilize the ECs and could be applied as candidates to synthesize stable VLPs as future genome-free poliovirus vaccines. PMID:27928008
Use of eddy current mixes to solve a weld examination application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, R.C.; LaBoissonniere, A.
1995-12-31
The augmentation of typical nondestructive (i.e., ultrasound) weld inspection techniques by the use of eddy current tools may significantly enhance the quality and reliability of weld inspections. One recent example is the development of an eddy current technique for use in the examination of BWR core shroud welds, where multi-frequency mixes are used to eliminate signals coming from the weld material so that the examination of the heat affected zone is enhanced. An analysis tool most commonly associated with ultrasound examinations, the C-Scan based on gated information, may be implemented with eddy current data to enhance analysis.
Thermal Protection System Imagery Inspection Management System -TIIMS
NASA Technical Reports Server (NTRS)
Goza, Sharon; Melendrez, David L.; Henningan, Marsha; LaBasse, Daniel; Smith, Daniel J.
2011-01-01
TIIMS is used during the inspection phases of every mission to provide quick visual feedback, detailed inspection data, and determination to the mission management team. This system consists of a visual Web page interface, an SQL database, and a graphical image generator. These combine to allow a user to ascertain quickly the status of the inspection process, and current determination of any problem zones. The TIIMS system allows inspection engineers to enter their determinations into a database and to link pertinent images and video to those database entries. The database then assigns criteria to each zone and tile, and via query, sends the information to a graphical image generation program. Using the official TIPS database tile positions and sizes, the graphical image generation program creates images of the current status of the orbiter, coloring zones, and tiles based on a predefined key code. These images are then displayed on a Web page using customized JAVA scripts to display the appropriate zone of the orbiter based on the location of the user's cursor. The close-up graphic and database entry for that particular zone can then be seen by selecting the zone. This page contains links into the database to access the images used by the inspection engineer when they make the determination entered into the database. Status for the inspection zones changes as determinations are refined and shown by the appropriate color code.
Surface contamination analysis technology team overview
NASA Technical Reports Server (NTRS)
Burns, H. Dewitt
1995-01-01
A team was established which consisted of representatives from NASA (Marshall Space Flight Center and Langley Research Center), Thiokol Corporation, the University of Alabama in Huntsville, AC Engineering, SAIC, Martin Marietta, and Aerojet. The team's purpose was to bring together the appropriate personnel to determine what surface inspection techniques were applicable to multiprogram bonding surface cleanliness inspection. In order to identify appropriate techniques and their sensitivity to various contaminant families, calibration standards were developed. Producing standards included development of consistent low level contamination application techniques. Oxidation was also considered for effect on inspection equipment response. Ellipsometry was used for oxidation characterization. Verification testing was then accomplished to show that selected inspection techniques could detect subject contaminants at levels found to be detrimental to critical bond systems of interest. Once feasibility of identified techniques was shown, selected techniques and instrumentation could then be incorporated into a multipurpose inspection head and integrated with a robot for critical surface inspection. Inspection techniques currently being evaluated include optically stimulated electron emission (OSEE); near infrared (NIR) spectroscopy utilizing fiber optics; Fourier transform infrared (FTIR) spectroscopy; and ultraviolet (UV) fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992 assuming appropriate funding levels are maintained. This paper gives an overview of work accomplished by the team and future plans.
Endothelial cells: From innocent bystanders to active participants in immune responses.
Al-Soudi, A; Kaaij, M H; Tas, S W
2017-09-01
The endothelium is crucially important for the delivery of oxygen and nutrients throughout the body under homeostatic conditions. However, it also contributes to pathology, including the initiation and perpetuation of inflammation. Understanding the function of endothelial cells (ECs) in inflammatory diseases and molecular mechanisms involved may lead to novel approaches to dampen inflammation and restore homeostasis. In this article, we discuss the various functions of ECs in inflammation with a focus on pathological angiogenesis, attraction of immune cells, antigen presentation, immunoregulatory properties and endothelial-to-mesenchymal transition (EndMT). We also review the current literature on approaches to target these processes in ECs to modulate immune responses and advance anti-inflammatory therapies. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gen, Mitsuo; Kawakami, Hiroshi; Tsujimura, Yasuhiro; Handa, Hisashi; Lin, Lin; Okamoto, Azuma
As efficient utilization of computational resources is increasing, evolutionary technology based on the Genetic Algorithm (GA), Genetic Programming (GP), Evolution Strategy (ES) and other Evolutionary Computations (ECs) is making rapid progress, and its social recognition and the need as applied technology are increasing. This is explained by the facts that EC offers higher robustness for knowledge information processing systems, intelligent production and logistics systems, most advanced production scheduling and other various real-world problems compared to the approaches based on conventional theories, and EC ensures flexible applicability and usefulness for any unknown system environment even in a case where accurate mathematical modeling fails in the formulation. In this paper, we provide a comprehensive survey of the current state-of-the-art in the fundamentals and applications of evolutionary technologies.
Error Sources in Proccessing LIDAR Based Bridge Inspection
NASA Astrophysics Data System (ADS)
Bian, H.; Chen, S. E.; Liu, W.
2017-09-01
Bridge inspection is a critical task in infrastructure management and is facing unprecedented challenges after a series of bridge failures. The prevailing visual inspection was insufficient in providing reliable and quantitative bridge information although a systematic quality management framework was built to ensure visual bridge inspection data quality to minimize errors during the inspection process. The LiDAR based remote sensing is recommended as an effective tool in overcoming some of the disadvantages of visual inspection. In order to evaluate the potential of applying this technology in bridge inspection, some of the error sources in LiDAR based bridge inspection are analysed. The scanning angle variance in field data collection and the different algorithm design in scanning data processing are the found factors that will introduce errors into inspection results. Besides studying the errors sources, advanced considerations should be placed on improving the inspection data quality, and statistical analysis might be employed to evaluate inspection operation process that contains a series of uncertain factors in the future. Overall, the development of a reliable bridge inspection system requires not only the improvement of data processing algorithms, but also systematic considerations to mitigate possible errors in the entire inspection workflow. If LiDAR or some other technology can be accepted as a supplement for visual inspection, the current quality management framework will be modified or redesigned, and this would be as urgent as the refine of inspection techniques.
Eddy-Current Detection of Cracks in Tubes
NASA Technical Reports Server (NTRS)
Parent, R.; Kettering, D.
1987-01-01
Nondestructive device tests narrow, sharply-bent metal tubes. Eddycurrent probe detects incipient cracks inside small metal tubes. Tube-centering device consisting of pair of opposed bars ensures tube centered on eddy-current coil. Probe moves along length of bent tube to inspect repeatably for cracks. Compatible with tubes of different cross sections, oval, flattened, square, rectangular,or irregular. Adapts for inspecting formed tubes in petrochemical, automotive, nuclear, and medical equipment.
NASA Technical Reports Server (NTRS)
Miller, James G. (Principal Investigator)
1996-01-01
Current concern for ensuring, the air-worthiness of the aging commercial air fleet has prompted the establishment of broad-agency programs to develop NDT technologies that address specific aging-aircraft issues. One of the crucial technological needs that has been identified is the development of rapid, quantitative systems for depot-level inspection of bonded aluminum lap joints on aircraft. Research results for characterization of disbond and corrosion based on normal-incidence pulse-echo measurement geometries are showing promise, but are limited by the single-site nature of the measurement which requires manual or mechanical scanning to inspect an area. One approach to developing efficient systems may be to transfer specific aspects of current medical imaging technology to the NDT arena. Ultrasonic medical imaging, systems offer many desirable attributes for large scale inspection. They are portable, provide real-time imaging, and have integrated video tape recorder and printer capabilities available for documentation and post-inspection review. Furthermore, these systems are available at a relatively low cost (approximately $50,000 to $200,000) and can be optimized for use with metals with straight-forward modifications.
Automated eddy current inspection of Space Shuttle APU turbine wheel blades
NASA Technical Reports Server (NTRS)
Fisher, Jay L.; Rowland, Stephen N.; Stolte, Jeffrey S.; Salkowski, Charles
1991-01-01
An automated inspection system based on eddy current testing (ET) techniques has been developed to inspect turbine wheel blades on the APU used in NASA's Space Transportation system. The APU is a hydrazine-powered gas turbine with a 15-cm diameter Rene 41 turbine wheel, which has 123 first-stage blades and 123 second-stage blades. The flaw detection capability of the ET system is verified through comparison with fluorescent penetrant test results. Results of the comparison indicate that ET is capable of inspecting surfaces with very restrictive geometries. The ET capability requires development of probes with extremely small coils to allow inspection within 0.4 mm of the blade root and the leading and trailing edges of the blade and within a height restriction of less than 1 mm. The color 2D presentation of the ET data provided crack-growth pattern and length information similar to those found with visual techniques. It also provided visual clues to minimize geometry effects such as generated from blade edges, a neighoring blade, and changes in the blade thickness.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...
Rifai, Damhuji; Abdalla, Ahmed N; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A
2017-03-13
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient.
Poli, F. M.; Andre, R. G.; Bertelli, N.; ...
2015-10-30
One of the goals of the National Spherical Torus Experiment Upgrade (NSTX-U) (Menard et al 2012 Nucl. Fusion 52 083015) is the demonstration of fully non-inductive start-up, current ramp-up and sustainment. This work discusses predictive simulations where the available heating and current drive systems are combined to maximize the non-inductive current and minimize the solenoidal contribution. Radio-frequency waves at harmonics higher than the ion cyclotron resonance (high-harmonic fast waves (HHFW)) and neutral beam injection are used to ramp the plasma current non-inductively starting from an initial Ohmic plasma. An interesting synergy is observed in the simulations between the HHFW andmore » electron cyclotron (EC) wave heating. Furthermore, time-dependent simulations indicate that, depending on the phasing of the HHFW antenna, EC wave heating can significantly increase the effectiveness of the radio-frequency power, by heating the electrons and increasing the current drive efficiency, thus relaxing the requirements on the level of HHFW power that needs to be absorbed in the core plasma to drive the same amount of fast-wave current.« less
Distribution of Plasmoids in Post-Coronal Mass Ejection Current Sheets
NASA Astrophysics Data System (ADS)
Bhattacharjee, A.; Guo, L.; Huang, Y.
2013-12-01
Recently, the fragmentation of a current sheet in the high-Lundquist-number regime caused by the plasmoid instability has been proposed as a possible mechanism for fast reconnection. In this work, we investigate this scenario by comparing the distribution of plasmoids obtained from Large Angle and Spectrometric Coronagraph (LASCO) observational data of a coronal mass ejection event with a resistive magnetohydrodynamic simulation of a similar event. The LASCO/C2 data are analyzed using visual inspection, whereas the numerical data are analyzed using both visual inspection and a more precise topological method. Contrasting the observational data with numerical data analyzed with both methods, we identify a major limitation of the visual inspection method, due to the difficulty in resolving smaller plasmoids. This result raises questions about reports of log-normal distributions of plasmoids and other coherent features in the recent literature. Based on nonlinear scaling relations of the plasmoid instability, we infer a lower bound on the current sheet width, assuming the underlying mechanism of current sheet broadening is resistive diffusion.
Assessment of the Automotive Inspection, Maintenance, and Repair Industry
DOT National Transportation Integrated Search
1981-02-01
The study describes the current status of the Inspection/Maintenance/Repair Industry in the U.S., the impact of technological changes and legislation, and related approaches used in Germany and Sweden. Based on these findings suggestions are provided...
Characterization of Stress Corrosion Cracking Using Laser Ultrasonics
DOT National Transportation Integrated Search
2008-08-31
In-service inspection of gas and oil pipelines is a subject of great current interest. Issues of safety and fitness for service have driven extensive efforts to develop effective monitoring and inspection techniques. A number of effective NDT techniq...
Thin Wall Pipe Ultrasonic Inspection through Paint Coating
NASA Astrophysics Data System (ADS)
Predoi, Mihai Valentin; Petre, Cristian Cătălin
Classical ultrasonic inspection of welds is currently done for plates thicker than 8 mm. The inspection of but welds in thin walled pipes has considerable implementation difficulties, due to guided waves dominating ultrasonic pulses propagation. Generation of purely symmetric modes, either torsional or longitudinal, requires a circumferential uniform distribution of transducers and dedicated inspection equipment, which are increasing the inspection costs. Moreover, if the surface is paint coated, the received signals are close to the detection level. The present work implies a single transducer, coupled to the painted surface. The proper choice of the guided mode and frequency range, allows the detection of a standard, small diameter through thickness hole. In this way, the inspection of pipe welds can use the same equipment as for thick materials, with only wedge adaptation.
Innovative use of global navigation satellite systems for flight inspection
NASA Astrophysics Data System (ADS)
Kim, Eui-Ho
The International Civil Aviation Organization (ICAO) mandates flight inspection in every country to provide safety during flight operations. Among many criteria of flight inspection, airborne inspection of Instrument Landing Systems (ILS) is very important because the ILS is the primary landing guidance system worldwide. During flight inspection of the ILS, accuracy in ILS landing guidance is checked by using a Flight Inspection System (FIS). Therefore, a flight inspection system must have high accuracy in its positioning capability to detect any deviation so that accurate guidance of the ILS can be maintained. Currently, there are two Automated Flight Inspection Systems (AFIS). One is called Inertial-based AFIS, and the other one is called Differential GPS-based (DGPS-based) AFIS. The Inertial-based AFIS enables efficient flight inspection procedures, but its drawback is high cost because it requires a navigation-grade Inertial Navigation System (INS). On the other hand, the DGPS-based AFIS has relatively low cost, but flight inspection procedures require landing and setting up a reference receiver. Most countries use either one of the systems based on their own preferences. There are around 1200 ILS in the U.S., and each ILS must be inspected every 6 to 9 months. Therefore, it is important to manage the airborne inspection of the ILS in a very efficient manner. For this reason, the Federal Aviation Administration (FAA) mainly uses the Inertial-based AFIS, which has better efficiency than the DGPS-based AFIS in spite of its high cost. Obviously, the FAA spends tremendous resources on flight inspection. This thesis investigates the value of GPS and the FAA's augmentation to GPS for civil aviation called the Wide Area Augmentation System (or WAAS) for flight inspection. Because standard GPS or WAAS position outputs cannot meet the required accuracy for flight inspection, in this thesis, various algorithms are developed to improve the positioning ability of Flight Inspection Systems (FIS) by using GPS and WAAS in novel manners. The algorithms include Adaptive Carrier Smoothing (ACS), optimizing WAAS accuracy and stability, and reference point-based precise relative positioning for real-time and near-real-time applications. The developed systems are WAAS-aided FIS, WAAS-based FIS, and stand-alone GPS-based FIS. These systems offer both high efficiency and low cost, and they have different advantages over one another in terms of accuracy, integrity, and worldwide availability. The performance of each system is tested with experimental flight test data and shown to have accuracy that is sufficient for flight inspection and superior to the current Inertial-based AFIS.
Dia, Oumar; Drogui, Patrick; Buelna, Gerardo; Dubé, Rino; Ihsen, Ben Salah
2017-02-01
Electrocoagulation (EC) was employed to treat residual organic matter from a landfill leachate pretreated by an aerated bio-filter system. Organic matter (humic acids (HA), fulvic acids (FA) and hydrophilic compounds (Hyl)) was fractionated using DAX-8 resin in order to estimate the efficiency of EC on each fraction. Initial characterization of the bio-filtrated landfill leachate showed that humic substances (HA + FA) represented nearly 90% of TOC. The effects of current densities, type of anode (Aluminum versus iron), and treatment time on the performance of COD removal were investigated. The best COD removal performances were recorded at a current density ranging between 8.0 and 10 mA cm -2 during 20 min of treatment time. Under these conditions, 70% and 65% of COD were removed using aluminum and iron electrodes, respectively. The fractionating of organic matter after EC treatment revealed that HA was completely removed using either aluminum or iron anode. However, FA and Hyl fractions were partially removed, with the percentages varying from 57 to 60% and 37-46%, respectively. FA and Hyl removal were quite similar using either aluminum or iron anode. Likewise, a significant decrease in 254-nm absorbance was recorded (UV 254 removal of 79-80%) using either type of anode. These results proved that EC is a suitable and efficient approach for treating the residual refractory organic matter from a landfill leachate previously treated by a biological system. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hernández-Ochoa, Erick O.; Schneider, Martin F.
2012-01-01
Skeletal muscle excitation-contraction (E-C)1 coupling is a process composed of multiple sequential stages, by which an action potential triggers sarcoplasmic reticulum (SR)2 Ca2+ release and subsequent contractile activation. The various steps in the E-C coupling process in skeletal muscle can be studied using different techniques. The simultaneous recordings of sarcolemmal electrical signals and the accompanying elevation in myoplasmic Ca2+, due to depolarization-initiated SR Ca2+ release in skeletal muscle fibres, have been useful to obtain a better understanding of muscle function. In studying the origin and mechanism of voltage dependency of E-C coupling a variety of different techniques have been used to control the voltage in adult skeletal fibres. Pioneering work in muscles isolated from amphibians or crustaceans used microelectrodes or ‘high resistance gap’ techniques to manipulate the voltage in the muscle fibres. The development of the patch clamp technique and its variant, the whole-cell clamp configuration that facilitates the manipulation of the intracellular environment, allowed the use of the voltage clamp techniques in different cell types, including skeletal muscle fibres. The aim of this article is to present an historical perspective of the voltage clamp methods used to study skeletal muscle E-C coupling as well as to describe the current status of using the whole-cell patch clamp technique in studies in which the electrical and Ca2+ signalling properties of mouse skeletal muscle membranes are being investigated. PMID:22306655
Gakhar, Gunjan; Bander, Neil H.; Nanus, David M.
2014-01-01
Metastasis is a process in which tumor cells shed from the primary tumor intravasate blood vascular and lymphatic system, thereby, gaining access to extravasate and form a secondary niche. The extravasation of tumor cells from the blood vascular system can be studied using endothelial cells (ECs) and tumor cells obtained from different cell lines. Initial studies were conducted using static conditions but it has been well documented that ECs behave differently under physiological flow conditions. Therefore, different flow chamber assemblies are currently being used to studying cancer cell interactions with ECs. Current flow chamber assemblies offer reproducible results using either different cell lines or fluid at different shear stress conditions. However, to observe and study interactions with rare cells such as circulating tumor cells (CTCs), certain changes are required to be made to the conventional flow chamber assembly. CTCs are a rare cell population among millions of blood cells. Consequently, it is difficult to obtain a pure population of CTCs. Contamination of CTCs with different types of cells normally found in the circulation is inevitable using present enrichment or depletion techniques. In the present report, we describe a unique method to fluorescently label circulating prostate cancer cells and study their interactions with ECs in a self-assembled flow chamber system. This technique can be further applied to observe interactions between prostate CTCs and any protein of interest. PMID:24894373
Tong, Wing-Chiu; Choi, Cecilia Y; Kharche, Sanjay; Karche, Sanjay; Holden, Arun V; Zhang, Henggui; Taggart, Michael J
2011-04-29
Uterine contractions during labor are discretely regulated by rhythmic action potentials (AP) of varying duration and form that serve to determine calcium-dependent force production. We have employed a computational biology approach to develop a fuller understanding of the complexity of excitation-contraction (E-C) coupling of uterine smooth muscle cells (USMC). Our overall aim is to establish a mathematical platform of sufficient biophysical detail to quantitatively describe known uterine E-C coupling parameters and thereby inform future empirical investigations of physiological and pathophysiological mechanisms governing normal and dysfunctional labors. From published and unpublished data we construct mathematical models for fourteen ionic currents of USMCs: Ca2+ currents (L- and T-type), Na+ current, an hyperpolarization-activated current, three voltage-gated K+ currents, two Ca2+-activated K+ current, Ca2+-activated Cl current, non-specific cation current, Na+-Ca2+ exchanger, Na+-K+ pump and background current. The magnitudes and kinetics of each current system in a spindle shaped single cell with a specified surface area:volume ratio is described by differential equations, in terms of maximal conductances, electrochemical gradient, voltage-dependent activation/inactivation gating variables and temporal changes in intracellular Ca2+ computed from known Ca2+ fluxes. These quantifications are validated by the reconstruction of the individual experimental ionic currents obtained under voltage-clamp. Phasic contraction is modeled in relation to the time constant of changing [Ca2+]i. This integrated model is validated by its reconstruction of the different USMC AP configurations (spikes, plateau and bursts of spikes), the change from bursting to plateau type AP produced by estradiol and of simultaneous experimental recordings of spontaneous AP, [Ca2+]i and phasic force. In summary, our advanced mathematical model provides a powerful tool to investigate the physiological ionic mechanisms underlying the genesis of uterine electrical E-C coupling of labor and parturition. This will furnish the evolution of descriptive and predictive quantitative models of myometrial electrogenesis at the whole cell and tissue levels.
Guimarães-Costa, Raquel; Guimarães-Costa, Maria Beatriz; Pippa-Gadioli, Leonardo; Weltson, Alfredo; Ubiali, Walter Adriano; Paschoalin-Maurin, Tatiana; Felippotti, Tatiana Tocchini; Elias-Filho, Daoud Hibrahim; Laure, Carlos Júlio; Coimbra, Norberto Cysne
2007-09-15
Defensive behaviour has been extensively studied, and non-invasive methodologies may be interesting approaches to analyzing the limbic system function as a whole. Using experimental models of animals in the state of anxiety has been fundamental in the search for new anxiolytic and antipanic compounds. The aim of this present work is to examine a new model for the study of affective behaviour, using a complex labyrinth consisting of an arena and galleries forming a maze. Furthermore, it aims to compare the defensive behaviour of Wistar rats, Mongolian gerbils and golden hamsters in a complex labyrinth, as well as the defensive behaviour of Meriones unguiculatus in aggressive encounters with either Epicrates cenchria assisi or Boa constrictor amarali in this same model. Among species presently studied, the Mongolian gerbils showed better performance in the exploration of both arena and galleries of the labyrinth, also demonstrating less latency in finding exits of the galleries. This increases the possibility of survival, as well as optimizes the events of encounter with the predator. The duration of alertness and freezing increased during confrontation with living Epicrates, as well as the duration of exploratory behaviour in the labyrinth. There was an increase in the number of freezing and alertness behaviours, as well as in duration of alertness during confrontations involving E.c. assisi, compared with behavioural reactions elicited by jirds in presence of B.c. amarali. Interestingly, the aggressive behaviour of Mongolian gerbils was more prominent against B.c. amarali compared with the other Boidae snake. E.c. assisi elicited more offensive attacks and exhibited a greater time period of body movement than B.c. amarali, which spent more time in the arena and in defensive immobility than the E.c. assisi. Considering that jirds evoked more fear-like reaction in contact with E.c. assisi, a fixed E.c. assisi kept in a hermetically closed acrylic box was used as control. In these prey/predator encounter-based experiments, there was an increase in the number of alertness and freezing behaviours exhibited by gerbils, and a decrease in the number of crossing elicited by them, when comparing confrontations between the living E.c. assisi and the control. The experiments were performed at 7.0 p.m. In the labyrinth, the snakes showed in confrontation similar performance to that observed in nature (organizing hunting behaviour, offensive/defensive attack, constriction, prey inspection and feeding behaviour), which were essential to the validity of the experiments and gave behavioural validation within the complex labyrinth.
Parent Education: What We Mean and What that Means.
ERIC Educational Resources Information Center
McCollum, Jeanette A.
1999-01-01
This response to Mahoney et al. (EC 623 392) agrees that there is currently less emphasis on parent education in the early-intervention literature but suggests that the current emphasis on family-centered services can be integrated with parent education while supporting family empowerment. (DB)
Apparatus for inspecting piping
Zollingger, W.T.; Appel, D.K.; Park, L.R.
1995-03-21
An inspection rabbit is described for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON{trademark}). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system. 6 figures.
The influence of executive capacity on selective attention and subsequent processing
Daffner, Kirk R.; Tarbi, Elise C.; Haring, Anna E.; Zhuravleva, Tatyana Y.; Sun, Xue; Rentz, Dorene M.; Holcomb, Phillip J.
2012-01-01
Recent investigations that suggest selective attention (SA) is dependent on top-down control mechanisms lead to the expectation that individuals with high executive capacity (EC) would exhibit more robust neural indices of SA. This prediction was tested by using event-related potentials (ERPs) to examine differences in markers of information processing across 25 subjects divided into two groups based on high vs. average EC, as defined by neuropsychological test scores. Subjects performed an experimental task requiring SA to a specified color. In contrast to expectation, individuals with high and average EC did not differ in the size of ERP indices of SA: the anterior Selection Positivity (SP) and posterior Selection Negativity (SN). However, there were substantial differences between groups in markers of subsequent processing, including the anterior N2 (a measure of attentional control) and the P3a (an index of the orienting of attention). EC predicted speed of processing at both early and late attentional stages. Individuals with lower EC exhibited prolonged SN, P3a, and P3b latencies. However, the delays in carrying out SA operations did not account for subsequent delays in decision making, or explain excessive orienting and reduced attentional control mechanisms in response to stimuli that should have been ignored. SN latency, P3 latency, and the size of the anterior N2 made independent contributions to the variance of EC. In summary, our findings suggest that current views regarding the relationship between top-down control mechanisms and SA may need refinement. PMID:22701415
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMaster, B.W.; Jones, S.B.; Sitzler, J.L.
1995-06-01
This document is a compendium of results of the calendar year 1994 Monitor Well Inspection and Maintenance Program at the Department of Energy Y-12 Plant in Oak Ridge, Tennessee. This report documents the work relating to well inspections and maintenance requests. Inspections are implemented in order to better assess the condition and maintenance needs of wells that are actively being monitored. Currently this approach calls for inspecting all wells on a routine (annual or triennial) basis which are: (1) in an active sampling program; (2) included in a hydrologic study; or (3) not in service, but not scheduled for pluggingmore » and abandonment. Routine inspections help to ensure that representative groundwater samples and hydrologic data are being collected, and contribute to the life expectancy of each well. This report formally presents well inspection and maintenance activities that were conducted at the Y-12 Plant during 1994. All inspections were conducted between April and December.« less
NASA Astrophysics Data System (ADS)
Katase, Takayoshi; Onozato, Takaki; Hirono, Misako; Mizuno, Taku; Ohta, Hiromichi
2016-05-01
Proton and hydroxyl ion play an essential role for tuning functionality of oxides because their electronic state can be controlled by modifying oxygen off-stoichiometry and/or protonation. Tungsten trioxide (WO3), a well-known electrochromic (EC) material for smart window, is a wide bandgap insulator, whereas it becomes a metallic conductor HxWO3 by protonation. Although one can utilize electrochromism together with metal-insulator (MI) switching for one device, such EC-MI switching cannot be utilized in current EC devices because of their two-terminal structure with parallel-plate configuration. Here we demonstrate a transparent EC-MI switchable device with three-terminal TFT-type structure using amorphous (a-) WO3 channel layer, which was fabricated on glass substrate at room temperature. We used water-infiltrated nano-porous glass, CAN (calcium aluminate with nano-pores), as a liquid-leakage-free solid gate insulator. At virgin state, the device was fully transparent in the visible-light region. For positive gate voltage, the active channel became dark blue, and electrical resistivity of the a-WO3 layer drastically decreased with protonation. For negative gate voltage, deprotonation occurred and the active channel returned to transparent insulator. Good cycleability of the present transparent EC-MI switching device would have potential for the development of advanced smart windows.
Perception of autonomy and connectedness prior to the onset of anorexia nervosa and bulimia nervosa.
Huemer, Julia; Haidvogl, Maria; Mattejat, Fritz; Wagner, Gudrun; Nobis, Gerald; Fernandez-Aranda, Fernando; Collier, David A; Treasure, Janet L; Karwautz, Andreas F K
2012-01-01
This study examines retrospective correlates of nonshared family environment prior to onset of disease, by means of multiple familial informants, among anorexia and bulimia nervosa patients. A total of 332 participants was included (anorexia nervosa, restrictive type (AN-R): n = 41 plus families); bulimic patients (anorexia nervosa, binge-purging type; bulimia nervosa: n = 59 plus families). The EATAET Lifetime Diagnostic Interview was used to establish the diagnosis; the Subjective Family Image Test was used to derive emotional connectedness (EC) and individual autonomy (IA). Bulimic and AN-R patients perceived significantly lower EC prior to onset of disease compared to their healthy sisters. Bulimic patients perceived significantly lower EC prior to onset of disease compared to AN-R patients and compared to their mothers and fathers. A low family sum - sister pairs sum comparison - of EC had a significant influence on the risk of developing bulimia nervosa. Contrary to expectations, AN-R patients did not perceive significantly lower levels of IA compared to their sisters, prior to onset of disease. Findings of low IA in currently ill AN-R patients may represent a disease consequence, not a risk factor. Developmental child psychiatrists should direct their attention to disturbances of EC, which may be present prior to the onset of the disease.
Endocannabinoid system dysfunction in mood and related disorders.
Ashton, C H; Moore, P B
2011-10-01
The endocannabinoid (EC) system is widely distributed throughout the brain and modulates many functions. It is involved in mood and related disorders, and its activity may be modified by exogenous cannabinoids. This article examines the therapeutic potential of cannabinoids in psychiatric disorders. An overview is presented of the literature focussed on the functions of the EC system, its dysfunction in mood disorders and the therapeutic potential of exogenous cannabinoids. We propose (hypothesize) that the EC system, which is homoeostatic in cortical excitation and inhibition, is dysfunctional in mood and related disorders. Anandamide, tetrahydrocannabinol (THC) and cannabidiol (CBD) variously combine antidepressant, antipsychotic, anxiolytic, analgesic, anticonvulsant actions, suggesting a therapeutic potential in mood and related disorders. Currently, cannabinoids find a role in pain control. Post mortem and other studies report EC system abnormalities in depression, schizophrenia and suicide. Abnormalities in the cannabinoid-1 receptor (CNR1) gene that codes for cannabinoid-1 (CB1) receptors are reported in psychiatric disorders. However, efficacy trials of cannabinoids in psychiatric disorders are limited but offer some encouragement. Research is needed to elucidate the role of the EC system in psychiatric disorders and for clinical trials with THC, CBD and synthetic cannabinoids to assess their therapeutic potential. © 2011 John Wiley & Sons A/S.
McAlpine, Jessica N; Greimel, Elfriede; Brotto, Lori A; Nout, Remy A; Shash, Emad; Avall-Lundqvist, Elisabeth; Friedlander, Michael L; Joly, Florence
2014-11-01
Quality of life (QoL) in endometrial cancer (EC) is understudied. Incorporation of QoL questionnaires and patient-reported outcomes in clinical trials has been inconsistent, and the tools and interpretation of these measures are unfamiliar to most practitioners. In 2012, the Gynecologic Cancer InterGroup Symptom Benefit Working Group convened for a brainstorming collaborative session to address deficiencies and work toward improving the quality and quantity of QoL research in women with EC. Through literature review and international expert contributions, we compiled a comprehensive appraisal of current generic and disease site-specific QoL assessment tools, strengths and weaknesses of these measures, assessment of sexual health, statistical considerations, and an exploration of the unique array of histopathologic and clinical factors that may influence QoL outcomes in women with EC. This collaborative composition is the first publication specific to EC that addresses methodology in QoL research and the components necessary to achieve high quality QoL data in clinical trials. Future recommendations regarding (1) the incorporation of patient-reported outcomes in all clinical trials in EC, (2) definition of an a priori hypothesis, (3) utilization of validated tools and consideration of new tools corresponding to new therapies or specific symptoms, (4) publication within the same time frame as clinical outcome data, and (5) attempt to correct for disease site-specific potential confounders are presented. Improved understanding of methodology in QoL research and an increased undertaking of EC-specific QoL research in clinical trials are imperative if we are to improve outcomes in women with EC.
Normal T-cell activation in elite controllers with preserved CD4+ T-cell counts.
Bansal, Anju; Sterrett, Sarah; Erdmann, Nathan; Westfall, Andrew O; Dionne-Odom, Jodie; Overton, Edgar T; Goepfert, Paul A
2015-11-01
HIV elite controllers suppress HIV viremia without antiretroviral therapy (ART), yet previous studies demonstrated that elite controllers maintain an activated T-cell phenotype. Chronic immune activation has detrimental consequences and thus ART has been advocated for all elite controllers. However, elite controllers are not a clinically homogenous group. Since CD4% is among the best predictors of AIDS-related events, in the current study, we assessed whether this marker can be used to stratify elite controllers needing ART. Sixteen elite controllers were divided into two groups based on CD4% (EC > 40% and EC ≤40%), and T-cell subsets were analyzed for markers of memory/differentiation (CD45RA, CCR7, CD28), activation (CD38/HLA-DR), immunosenescence (CD57), costimulation (CD73, CD28) and exhaustion (PD-1, CD160, Tim-3). Monocyte subsets (CD14, CD16) were also analyzed and sCD14 levels were quantified using ELISA. In the EC group, expression of activation, exhaustion, and immunosensescence markers on T cells were significantly reduced compared with the EC group and similar to the seronegative controls. The EC group expressed higher levels of costimulatory molecules CD28 and CD73 and had lower levels of monocyte activation (HLA-DR expression) with a reduced frequency of inflammatory monocyte (CD14 CD16) subset. Furthermore, the EC group maintained a stable CD4% during a median follow-up of 6 years. Elite controllers with preserved CD4T cells (EC) have normal T-cell and monocyte phenotypes and therefore may have limited benefit from ART. CD4% can be an important marker for evaluating future studies aimed at determining the need for ART in this group of individuals.
DeBernardo, Robert L; Littell, Ramey D; Luo, Hongwei; Duska, Linda R; Oliva, Esther; Kirley, Sandra D; Lynch, Maureen P; Zukerberg, Lawrence R; Rueda, Bo R
2005-01-01
Loss of Cables expression is associated with a high incidence of endometrial hyperplasia and endometrial adenocarcinoma in humans. The Cables mutant mouse develops endometrial hyperplasia and following exposure to chronic estrogen develops early endometrial adenocarcinoma. The objectives of the current study were to determine if: (1) loss of Cables expression occurred in high grade endometrioid adenocarcinoma, uterine serous and clear cell carcinoma as observed in endometrial hyperplasia and low grade endometrial adenocarcinoma; (2) overexpression of Cables inhibited cell proliferation in endometrial cancer (EC) cells in vitro and in vivo; and (3) progesterone could regulate the expression of Cables mRNA. Hyperplastic endometrium and low and high grade endometrioid adenocarcinoma showed loss of Cables expression when compared to benign control secretory endometrium. Loss of Cables expression in serous and clear cell tumors was similar to that observed in endometrioid adenocarcinomas with greater than 80% showing loss of protein expression. Treatment of EC lines with progesterone increased cables expression in low-grade EC whereas it had no effect on cables expression in cells derived from high-grade EC. The progesterone-induced increase in cables was abrogated in the presence of a progesterone receptor (PR) antagonist, suggesting the PR mediates the increase. Cables overexpression inhibited cell proliferation of well differentiated EC cells and had no effect on the poorly differentiated EC cells. The capacity to form tumors was dramatically reduced in the Cables overexpressing cell lines compared to those cells containing the control vector. Collectively these results suggest that Cables is an important regulator of cell proliferation and loss of Cables expression contributes to the development of all types of EC.
Tripathi, Jaindra N; Oduor, Richard O; Tripathi, Leena
2015-01-01
Banana (Musa spp.) is an important staple food as well as cash crop in tropical and subtropical countries. Various bacterial, fungal, and viral diseases and pests such as nematodes are major constraints in its production and are currently destabilizing the banana production in sub-Saharan Africa. Genetic engineering is a complementary option used for incorporating useful traits in banana to bypass the long generation time, polyploidy, and sterility of most of the cultivated varieties. A robust transformation protocol for farmer preferred varieties is crucial for banana genomics and improvement. A robust and reproducible system for genetic transformation of banana using embryogenic cell suspensions (ECS) has been developed in this study. Two different types of explants (immature male flowers and multiple buds) were tested for their ability to develop ECS in several varieties of banana locally grown in Africa. ECS of banana varieties "Cavendish Williams" and "Gros Michel" were developed using multiple buds, whereas ECS of "Sukali Ndiizi" was developed using immature male flowers. Regeneration efficiency of ECS was about 20,000-50,000 plantlets per ml of settled cell volume (SCV) depending on variety. ECS of three different varieties were transformed through Agrobacterium-mediated transformation using gusA reporter gene and 20-70 independent transgenic events per ml SCV of ECS were regenerated on selective medium. The presence and integration of gusA gene in transgenic plants was confirmed by PCR, dot blot, and Southern blot analysis and expression by histochemical GUS assays. The robust transformation platform was successfully used to generate hundreds of transgenic lines with disease resistance. Such a platform will facilitate the transfer of technologies to national agricultural research systems (NARS) in Africa.
Tripathi, Jaindra N.; Oduor, Richard O.; Tripathi, Leena
2015-01-01
Banana (Musa spp.) is an important staple food as well as cash crop in tropical and subtropical countries. Various bacterial, fungal, and viral diseases and pests such as nematodes are major constraints in its production and are currently destabilizing the banana production in sub-Saharan Africa. Genetic engineering is a complementary option used for incorporating useful traits in banana to bypass the long generation time, polyploidy, and sterility of most of the cultivated varieties. A robust transformation protocol for farmer preferred varieties is crucial for banana genomics and improvement. A robust and reproducible system for genetic transformation of banana using embryogenic cell suspensions (ECS) has been developed in this study. Two different types of explants (immature male flowers and multiple buds) were tested for their ability to develop ECS in several varieties of banana locally grown in Africa. ECS of banana varieties “Cavendish Williams” and “Gros Michel” were developed using multiple buds, whereas ECS of “Sukali Ndiizi” was developed using immature male flowers. Regeneration efficiency of ECS was about 20,000–50,000 plantlets per ml of settled cell volume (SCV) depending on variety. ECS of three different varieties were transformed through Agrobacterium-mediated transformation using gusA reporter gene and 20–70 independent transgenic events per ml SCV of ECS were regenerated on selective medium. The presence and integration of gusA gene in transgenic plants was confirmed by PCR, dot blot, and Southern blot analysis and expression by histochemical GUS assays. The robust transformation platform was successfully used to generate hundreds of transgenic lines with disease resistance. Such a platform will facilitate the transfer of technologies to national agricultural research systems (NARS) in Africa. PMID:26635849
Dang, Shilpa; Chaudhury, Santanu; Lall, Brejesh; Roy, Prasun Kumar
2017-06-15
Determination of effective connectivity (EC) among brain regions using fMRI is helpful in understanding the underlying neural mechanisms. Dynamic Bayesian Networks (DBNs) are an appropriate class of probabilistic graphical temporal-models that have been used in past to model EC from fMRI, specifically order-one. High-order DBNs (HO-DBNs) have still not been explored for fMRI data. A fundamental problem faced in the structure-learning of HO-DBN is high computational-burden and low accuracy by the existing heuristic search techniques used for EC detection from fMRI. In this paper, we propose using dynamic programming (DP) principle along with integration of properties of scoring-function in a way to reduce search space for structure-learning of HO-DBNs and finally, for identifying EC from fMRI which has not been done yet to the best of our knowledge. The proposed exact search-&-score learning approach HO-DBN-DP is an extension of the technique which was originally devised for learning a BN's structure from static data (Singh and Moore, 2005). The effectiveness in structure-learning is shown on synthetic fMRI dataset. The algorithm reaches globally-optimal solution in appreciably reduced time-complexity than the static counterpart due to integration of properties. The proof of optimality is provided. The results demonstrate that HO-DBN-DP is comparably more accurate and faster than currently used structure-learning algorithms used for identifying EC from fMRI. The real data EC from HO-DBN-DP shows consistency with previous literature than the classical Granger Causality method. Hence, the DP algorithm can be employed for reliable EC estimates from experimental fMRI data. Copyright © 2017 Elsevier B.V. All rights reserved.
Overdevest, Ilse; Haverkate, Manon; Veenemans, Jacobien; Hendriks, Yvonne; Verhulst, Carlo; Mulders, Ans; Couprie, Willemijn; Bootsma, Martin; Johnson, James; Kluytmans, Jan
2016-10-20
The extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli clone ST131 (ESBL-ST131) has spread in healthcare settings worldwide. The reasons for its successful spread are unknown, but might include more effective transmission and/or longer persistence. We evaluated the colonisation dynamics of ESBL-producing E. coli (ESBL-EC), including ESBL-ST131, in a long-term care facility (LTCF) with an unusually high prevalence of rectal ESBL-EC colonisation. During a 14-month period, rectal or faecal samples were obtained from 296 residents during six repetitive prevalence surveys, using ESBL-selective culture. Transmission rates, reproduction numbers, and durations of colonisation were compared for ESBL-ST131 vs other ESBL-EC. Furthermore, the likely time required for ESBL-ST131 to disappear from the LTCF was estimated. Over time, the endemic level of ESBL-ST131 remained elevated whereas other ESBL-EC returned to low-level prevalence, despite comparable transmission rates. Survival analysis showed a half-life of 13 months for ESBL-ST131 carriage, vs two to three months for other ESBL-EC (p < 0.001). Per-admission reproduction numbers were 0.66 for ESBL-ST131 vs 0.56 for other ESBL-EC, predicting a mean time of three to four years for ESBL-ST131 to disappear from the LTCF under current conditions. Transmission rates were comparable for ESBL-ST131 vs other ESBL-EC. Prolonged rectal carriage explained the persistence of ESBL-ST131 in the LTCF. This article is copyright of The Authors, 2016.
Chiu, Jeng-Jiann; Chien, Shu
2013-01-01
Vascular endothelial cells (ECs) are exposed to hemodynamic forces, which modulate EC functions and vascular biology/pathobiology in health and disease. The flow patterns and hemodynamic forces are not uniform in the vascular system. In straight parts of the arterial tree, blood flow is generally laminar and wall shear stress is high and directed; in branches and curvatures, blood flow is disturbed with nonuniform and irregular distribution of low wall shear stress. Sustained laminar flow with high shear stress upregulates expressions of EC genes and proteins that are protective against atherosclerosis, whereas disturbed flow with associated reciprocating, low shear stress generally upregulates the EC genes and proteins that promote atherogenesis. These findings have led to the concept that the disturbed flow pattern in branch points and curvatures causes the preferential localization of atherosclerotic lesions. Disturbed flow also results in postsurgical neointimal hyperplasia and contributes to pathophysiology of clinical conditions such as in-stent restenosis, vein bypass graft failure, and transplant vasculopathy, as well as aortic valve calcification. In the venous system, disturbed flow resulting from reflux, outflow obstruction, and/or stasis leads to venous inflammation and thrombosis, and hence the development of chronic venous diseases. Understanding of the effects of disturbed flow on ECs can provide mechanistic insights into the role of complex flow patterns in pathogenesis of vascular diseases and can help to elucidate the phenotypic and functional differences between quiescent (nonatherogenic/nonthrombogenic) and activated (atherogenic/thrombogenic) ECs. This review summarizes the current knowledge on the role of disturbed flow in EC physiology and pathophysiology, as well as its clinical implications. Such information can contribute to our understanding of the etiology of lesion development in vascular niches with disturbed flow and help to generate new approaches for therapeutic interventions. PMID:21248169
Dai, Xinfeng; Lu, Douding; Guan, Weibing; Xia, Ping; Wang, Hongxia; He, Piaoxia; Zhang, Dongsheng
2013-01-01
During the last two decades, large-scale high biomass algal blooms of the dinoflagellate Prorocentrum donghaiense Lu have occurred frequently in the East China Sea (ECS). The role of increasing nutrient concentrations in driving those blooms is well-established, but the source population that initiates them is poorly understood. We hypothesized that the front of Taiwan Warm Current (TWC) may serve as a 'seed bank' that initiates P. donghaiense blooms in the ECS, as the physiochemical conditions in the TWC are suitable for the growth of P. donghaiense. In order to test this hypothesis, two surveys at different spatio-temporal scales were conducted in 2010 and 2011. We found a strong correlation in space and time between the abundance of P. donghaiense and the TWC. The spatial extent of the P. donghaiense bloom coincided with the TWC front in both 2010 and 2011. During the early development of the blooms, P. donghaiense concentration was highest at the TWC front, and then the bloom mass shifted inshore over the course of our 2011 survey. The TWC also moved inshore, albeit after the appearance of P. donghaiense. Overall, these results support our hypothesis that P. donghaiense blooms develop from the population at the TWC front in the ECS, suggesting the role of the ocean current front as a seed bank to dinoflagellate blooms.
NASA Astrophysics Data System (ADS)
Zhang, Peng; Tong, Man; Yuan, Songhu; Liao, Peng
2014-08-01
Oxidation of As(III) to As(V) is generally essential for the efficient remediation of As(III)-contaminated groundwater. The performance and mechanisms of As(III) oxidation by an as-synthesized active anode, SnO2 loaded onto Ti-based TiO2 nanotubes (Ti/TiO2NTs/Sb-SnO2), were investigated. The subsequent removal of total arsenic by electrocoagulation (EC) was further tested. The Ti/TiO2NTs/Sb-SnO2 anode showed a high and lasting electrochemical activity for As(III) oxidation. 6.67 μM As(III) in synthetic groundwater was completely oxidized to As(V) within 60 min at 50 mA. Direct electron transfer was mainly responsible at the current below 30 mA, while hydroxyl radicals contributed increasingly with the increase in the current above 30 mA. As(III) oxidation was moderately inhibited by the presence of bicarbonate (20 mM), while was dramatically increased with increasing the concentration of chloride (0-10 mM). After the complete oxidation of As(III) to As(V), total arsenic was efficiently removed by EC in the same reactor by reversing electrode polarity. The removal efficiency increased with increasing the current but decreased by the presence of phosphate and silica. Anodic oxidation represents an effective pretreatment approach to increasing EC removal of As(III) in groundwater under O2-limited conditions.
Redundant drive current imbalance problem of the Automatic Radiator Inspection Device (ARID)
NASA Technical Reports Server (NTRS)
Latino, Carl D.
1992-01-01
The Automatic Radiator Inspection Device (ARID) is a 4 Degree of Freedom (DOF) robot with redundant drive motors at each joint. The device is intended to automate the labor intensive task of space shuttle radiator inspection. For safety and redundancy, each joint is driven by two independent motor systems. Motors driving the same joint, however, draw vastly different currents. The concern was that the robot joints could be subjected to undue stress. It was the objective of this summer's project to determine the cause of this current imbalance. In addition it was to determine, in a quantitative manner, what was the cause, how serious the problem was in terms of damage or undue wear to the robot and find solutions if possible. It was concluded that most problems could be resolved with a better motor control design. This document discusses problems encountered and possible solutions.
Eddy current signal comparison for tube identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, S. W., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com; Vojvodic, R., E-mail: Bill.Glass@areva.com, E-mail: Ratko.Vojvodic@areva.com
2015-03-31
Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been somemore » instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.« less
46 CFR 189.01-10 - Period of validity for a Certificate of Inspection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... inspection at any time during the period of validity of the current certificate. (b) Certificates of... be issued for a specific period of time to cover a described situation or for one voyage only but not...
46 CFR 91.01-10 - Period of validity for a Certificate of Inspection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... inspection at any time during the period of validity of the current certificate. (b) Certificates of... be issued for a specific period of time to cover a described situation or for one voyage only but in...
Quality control and in-service inspection technology for hybrid-composite girder bridges.
DOT National Transportation Integrated Search
2014-08-01
This report describes efforts to develop quality control tools and in-service inspection technologies for the fabrication and construction of Hybrid Composite Beams (HCBs). HCBs are a new bridge technology currently being evaluated by the Missouri De...
An Extended Production and Inspection Model with Nonrigid Demand
Shih, Neng-Hui; Wang, Chih-Hsiung
2013-01-01
This paper extends a previous production and inspection (PI) model in relation to market demand that is nonrigid to consider an imperfect process that has a general hazard rate instead of a constant failure rate. Products are produced by an imperfect process that may shift randomly from the IN state to the OUT state. When the process is in the OUT state, it has a higher probability of producing a nonconforming product than when it is in the IN state. To achieve the zero defects policy, all products before delivery to the market should be inspected and the inspection order follows their production sequence. Furthermore, the inspection information from all previous products is used to decide either that the next candidate product should be inspected or that the inspection procedure for the current production lot should be terminated. When the inspection procedure is terminated, the remaining unmet demand is regarded as a shortage. An algorithm is developed to determine an optimal PI policy that minimizes the expected total cost, which includes the cost of inspection, of shortage, and of production. PMID:24396302
Smith, Nicole K; Cleland, Kelly; Wagner, Brandon; Trussell, James
2017-04-01
This study describes women's reasons for seeking ulipristal acetate (UPA) for emergency contraception (EC) through the only authorized online retailer for UPA EC in the US. Women aged 14 to 59 years, living in states that allow prescription medications to be shipped from out-of-state, accessed the KwikMed online pharmacy between January 2011 and December 2015. After completing a medical eligibility screener, women answered optional multiple-choice questions. To obtain UPA through KwikMed, individuals must be female, 50 years of age or younger, not currently pregnant or breastfeeding and not attempting to order UPA more than once within 30 days or more than four times per year. Over the 5-year period, KwikMed provided 8019 prescriptions for UPA, and the number of women using this service more than tripled over time. Among women who responded to the survey questions (n=7133; response rate = 89%), most sought EC because of a condom failure (45.3%) or because they did not use regular contraception (41.2%). More than half (53.5%) of women reported that they chose UPA because of its effectiveness compared to levonorgestrel EC pills, and 58.9% preferred ordering UPA online because they found it easier than getting it from a doctor, clinic or pharmacy. This study documents the importance of providing confidential services for acquiring EC online. Benefits of online access include convenience, less embarrassment, avoiding situations in which a provider might refuse to provide EC because of their own ideological belief and more reliable availability for this time-sensitive contraceptive. Though physical, logistical and societal barriers can restrict women's access to EC, this study demonstrates that providing access to UPA online empowers women to obtain EC when they need it. Copyright © 2016 Elsevier Inc. All rights reserved.
Weinberg, Z G; Chen, Y; Volchinski, V; Sela, S; Ogunade, I M; Adesogan, A
2016-07-01
Previous studies have shown that silages treated with lactic acid bacteria (LAB) inoculants enhance ruminants' performance. The objective of the current experiments was to develop an in vitro model to study interactions between LAB silage inoculants and inoculated silages and Escherichia coli (EC) in rumen fluid (RF). Our hypothesis was that some inoculants inhibit EC in RF. For that purpose buffered RF was incubated under anaerobic conditions at 39°C with commercial strains of LAB silage inoculants or with laboratory corn and wheat silages treated with these LAB, an EC strain and with various ruminant feed ingredients. The EC strain was originally isolated from cattle manure and tagged with a plasmid expressing the green fluorescence protein and kanamycin and streptomycin resistance. Results indicate that the LAB or the treated silages did not suppress EC numbers in the RF. When the pH of the RF decreased below 5·0 the EC disappeared. We conclude that both LAB inoculants for silage and EC survived in RF for several days; however, the inoculants and silages treated with such inoculants did not inhibit EC in RF in vitro. Forage crops, silage and hay are initial stages of the food chain for humans. Cattle harbours and sheds enterobacteria regularly, some strains of which are pathogens. These can contaminate forage crops through field fertilization with cattle manure. The objective of this study was to develop an in vitro model to test whether lactic acid bacteria, which are used in silage inoculants, alone or in treated silages can inhibit Escherichia coli in rumen fluid. This study presents safety aspects and it is also part of a broad research effort aimed at finding out how LAB silage inoculants and inoculated silages enhance ruminant performance or exert probiotic effects in ruminants. © 2016 The Society for Applied Microbiology.
ORENZA: a web resource for studying ORphan ENZyme activities
Lespinet, Olivier; Labedan, Bernard
2006-01-01
Background Despite the current availability of several hundreds of thousands of amino acid sequences, more than 36% of the enzyme activities (EC numbers) defined by the Nomenclature Committee of the International Union of Biochemistry and Molecular Biology (NC-IUBMB) are not associated with any amino acid sequence in major public databases. This wide gap separating knowledge of biochemical function and sequence information is found for nearly all classes of enzymes. Thus, there is an urgent need to explore these sequence-less EC numbers, in order to progressively close this gap. Description We designed ORENZA, a PostgreSQL database of ORphan ENZyme Activities, to collate information about the EC numbers defined by the NC-IUBMB with specific emphasis on orphan enzyme activities. Complete lists of all EC numbers and of orphan EC numbers are available and will be periodically updated. ORENZA allows one to browse the complete list of EC numbers or the subset associated with orphan enzymes or to query a specific EC number, an enzyme name or a species name for those interested in particular organisms. It is possible to search ORENZA for the different biochemical properties of the defined enzymes, the metabolic pathways in which they participate, the taxonomic data of the organisms whose genomes encode them, and many other features. The association of an enzyme activity with an amino acid sequence is clearly underlined, making it easy to identify at once the orphan enzyme activities. Interactive publishing of suggestions by the community would provide expert evidence for re-annotation of orphan EC numbers in public databases. Conclusion ORENZA is a Web resource designed to progressively bridge the unwanted gap between function (enzyme activities) and sequence (dataset present in public databases). ORENZA should increase interactions between communities of biochemists and of genomicists. This is expected to reduce the number of orphan enzyme activities by allocating gene sequences to the relevant enzymes. PMID:17026747
Williams, Monique; Bozhilov, Krassimir; Ghai, Sanjay; Talbot, Prue
2017-01-01
Objective Our purpose was to quantify 36 inorganic chemical elements in aerosols from disposable electronic cigarettes (ECs) and electronic hookahs (EHs), examine the effect of puffing topography on elements in aerosols, and identify the source of the elements. Methods Thirty-six inorganic chemical elements and their concentrations in EC/EH aerosols were determined using inductively coupled plasma optical emission spectroscopy, and their source was identified by analyzing disassembled atomizers using scanning electron microscopy and energy dispersive X-ray spectroscopy. Results Of 36 elements screened, 35 were detected in EC/EH aerosols, while only 15 were detected in conventional tobacco smoke. Some elements/metals were present in significantly higher concentrations in EC/EH aerosol than in cigarette smoke. Concentrations of particular elements/metals within EC/EH brands were sometimes variable. Aerosols generated at low and high air-flow rates produced the same pattern of elements, although the total element concentration decreased at the higher air flow rate. The relative amount of elements in the first and last 60 puffs was generally different. Silicon was the dominant element in aerosols from all EC/EH brands and in cigarette smoke. The elements appeared to come from the filament (nickel, chromium), thick wire (copper coated with silver), brass clamp (copper, zinc), solder joints (tin, lead), and wick and sheath (silicon, oxygen, calcium, magnesium, aluminum). Lead was identified in the solder and aerosol of two brands of EHs (up to 0.165 μg/10 puffs). Conclusion These data show that EC/EH aerosols contain a mixture of elements, including heavy metals, with concentrations often significantly higher than in conventional cigarette smoke. While the health effects of inhaling mixtures of heated metals is currently not known, these data will be valuable in future risk assessments involving EC/EH elements/metals. PMID:28414730
Current deflection NDE for pipeline inspection and monitoring
NASA Astrophysics Data System (ADS)
Jarvis, Rollo; Cawley, Peter; Nagy, Peter B.
2016-02-01
Failure of oil and gas pipelines can often be catastrophic, therefore routine inspection for time dependent degradation is essential. In-line inspection is the most common method used; however, this requires the insertion and retrieval of an inspection tool that is propelled by the fluid in the pipe and risks becoming stuck, so alternative methods must often be employed. This work investigates the applicability of a non-destructive evaluation technique for both the detection and growth monitoring of defects, particularly corrosion under insulation. This relies on injecting an electric current along the pipe and indirectly measuring the deflection of current around defects from perturbations in the orthogonal components of the induced magnetic flux density. An array of three orthogonally oriented anisotropic magnetoresistive sensors has been used to measure the magnetic flux density surrounding a 6'' schedule-40 steel pipe carrying 2 A quasi-DC axial current. A finite element model has been developed that predicts the perturbations in magnetic flux density caused by current deflection which has been validated by experimental results. Measurements of the magnetic flux density at 50 mm lift-off from the pipe surface are stable and repeatable to the order of 100 pT which suggests that defect detection or monitoring growth of corrosion-type defects may be possible with a feasible magnitude of injected current. Magnetic signals are additionally incurred by changes in the wall thickness of the pipe due to manufacturing tolerances, and material property variations. If a monitoring scheme using baseline subtraction is employed then the sensitivity to defects can be improved while avoiding false calls.
2014-01-01
Background Although serotype O157:H7 is the predominant enterohemorrhagic Escherichia coli (EHEC), outbreaks of non-O157 EHEC that cause severe foodborne illness, including hemolytic uremic syndrome have increased worldwide. In fact, non-O157 serotypes are now estimated to cause over half of all the Shiga toxin-producing Escherichia coli (STEC) cases, and outbreaks of non-O157 EHEC infections are frequently associated with serotypes O26, O45, O103, O111, O121, and O145. Currently, there are no complete genomes for O145 in public databases. Results We determined the complete genome sequences of two O145 strains (EcO145), one linked to a US lettuce-associated outbreak (RM13514) and one to a Belgium ice-cream-associated outbreak (RM13516). Both strains contain one chromosome and two large plasmids, with genome sizes of 5,737,294 bp for RM13514 and 5,559,008 bp for RM13516. Comparative analysis of the two EcO145 genomes revealed a large core (5,173 genes) and a considerable amount of strain-specific genes. Additionally, the two EcO145 genomes display distinct chromosomal architecture, virulence gene profile, phylogenetic origin of Stx2a prophage, and methylation profile (methylome). Comparative analysis of EcO145 genomes to other completely sequenced STEC and other E. coli and Shigella genomes revealed that, unlike any other known non-O157 EHEC strain, EcO145 ascended from a common lineage with EcO157/EcO55. This evolutionary relationship was further supported by the pangenome analysis of the 10 EHEC str ains. Of the 4,192 EHEC core genes, EcO145 shares more genes with EcO157 than with the any other non-O157 EHEC strains. Conclusions Our data provide evidence that EcO145 and EcO157 evolved from a common lineage, but ultimately each serotype evolves via a lineage-independent nature to EHEC by acquisition of the core set of EHEC virulence factors, including the genes encoding Shiga toxin and the large virulence plasmid. The large variation between the two EcO145 genomes suggests a distinctive evolutionary path between the two outbreak strains. The distinct methylome between the two EcO145 strains is likely due to the presence of a BsuBI/PstI methyltransferase gene cassette in the Stx2a prophage of the strain RM13514, suggesting a role of horizontal gene transfer-mediated epigenetic alteration in the evolution of individual EHEC strains. PMID:24410921
Brosnan, Robert J; Pham, Trung L
2011-03-01
Isoflurane and carbon dioxide (CO(2)) negatively modulate N-methyl-d-aspartate (NMDA) receptors, but via different mechanisms. Isoflurane is a competitive antagonist at the NMDA receptor glycine binding site, whereas CO(2) inhibits NMDA receptor current through extracellular acidification. Isoflurane and CO(2) exhibit additive minimum alveolar concentration effects in rats, but we hypothesized that they would not additively inhibit NMDA receptor currents in vitro because they act at different molecular sites. NMDA receptors were expressed in frog oocytes and studied using 2-electrode voltage clamp techniques. A glycine concentration response for NMDA was measured in the presence and absence of CO(2). Concentration-response curves for isoflurane, H(+), CO(2), and ketamine as a function of NMDA inhibition were measured, and a Hill equation was used to calculate the EC(50) for each compound. Binary drug combinations containing ½ EC(50) were additive if NMDA current inhibition was not statistically different from 50%. The ½ EC(50) binary drug combinations decreased the percentage baseline NMDA receptor current as follows (mean ± SD, n = 5 to 6 oocytes each): CO(2)+ H(+) (51% ± 5%), CO(2 )+ isoflurane (54% ± 5%), H(+) + isoflurane (51% ± 3%), CO(2)+ ketamine (67% ± 8%), and H(+) + ketamine (64% ± 2%). In contrast to our hypothesis, NMDA receptor inhibition by CO(2) and isoflurane is additive. Possibly, CO(2) acidification modulates a pH-sensitive loop on the NMDA receptor that in turn alters glycine binding affinity on the GluN1 subunit. However, ketamine plus either CO(2) or H(+) synergistically inhibits NMDA receptor currents. Drugs acting via different mechanisms can thus exhibit additive or synergistic receptor effects. Additivity may not robustly indicate commonality between molecular anesthetic mechanisms.
Fumagalli, Fabio; Pasini, Matteo; Sartorius, Alexander; Scherer, Rosine; Racagni, Giorgio; Riva, Marco A; Gass, Peter
2010-10-01
Glutamate and its receptors are involved in the pathophysiology of mood disorders and have recently emerged as potential targets for the pharmacotherapy of depression. In rats, we investigated plasticity changes of the glutamatergic system evoked by electroconvulsive shock (ECS), which represents the most effective therapy for patients who are refractory to antidepressants. Chronic ECS produced a marked increase in the phosphorylation of the regulatory NMDA receptor subunit NR2B (Ser1303) and the AMPA receptor subunit GluR-A (Ser831) in the hippocampus, with no effects on the obligatory subunit NR1. No effects were found on total receptor subunit expression levels. We suggest that, at least in part, ECS exerts its clinical activity through the modulation of the glutamatergic synapses, via potentiation of AMPA currents mediated by GluR-A (Ser831) phosphorylation, and a reduction of NMDA receptor activity through the phosphorylation of NR2B (Ser1303), presumably uncoupling NR2B from its signalling partner CaMKII. These effects functionally resemble the recently described antidepressant effects of ketamine.
Ince, Can; Mayeux, Philip R.; Nguyen, Trung; Gomez, Hernando; Kellum, John A.; Ospina-Tascón, Gustavo A.; Hernandez, Glenn; Murray, Patrick; De Backer, Daniel
2017-01-01
Sepsis affects practically all aspects of endothelial cell (EC) function and is thought to be the key factor in the progression from sepsis to organ failure. Endothelial functions affected by sepsis include vasoregulation, barrier function, inflammation, and hemostasis. These are among other mechanisms often mediated by glycocalyx shedding, such as abnormal nitric oxide metabolism, up-regulation of reactive oxygen species generation due to down-regulation of endothelial-associated antioxidant defenses, transcellular communication, proteases, exposure of adhesion molecules, and activation of tissue factor. This review covers current insight in EC-associated hemostatic responses to sepsis and the EC response to inflammation. The endothelial cell lining is highly heterogeneous between different organ systems and consequently also in its response to sepsis. In this context, we discuss the response of the endothelial cell lining to sepsis in the kidney, liver, and lung. Finally, we discuss evidence as to whether the EC response to sepsis is adaptive or maladaptive. This study is a result of an Acute Dialysis Quality Initiative XIV Sepsis Workgroup meeting held in Bogota, Columbia, between October 12 and 15, 2014. PMID:26871664
Franck, Grégory; Mawson, Thomas; Sausen, Grasiele; Salinas, Manuel; Masson, Gustavo Santos; Cole, Andrew; Beltrami-Moreira, Marina; Chatzizisis, Yiannis; Quillard, Thibault; Tesmenitsky, Yevgenia; Shvartz, Eugenia; Sukhova, Galina K.; Swirski, Filip K.; Nahrendorf, Matthias; Aikawa, Elena; Croce, Kevin J.; Libby, Peter
2017-01-01
Rationale Superficial erosion currently causes up to a third of acute coronary syndromes (ACS), yet we lack understanding of its mechanisms. Thrombi due to superficial intimal erosion characteristically complicate matrix-rich atheromata in regions of flow perturbation. Objective This study tested in vivo the involvement of disturbed flow, and of neutrophils, hyaluronan, and TLR2 ligation in superficial intimal injury, a process implicated in superficial erosion. Methods and Results : In mouse carotid arteries with established intimal lesions tailored to resemble the substrate of human eroded plaques, acute flow perturbation promoted downstream endothelial cell (EC) activation, neutrophil accumulation, EC death and desquamation, and mural thrombosis. Neutrophil loss-of-function limited these findings. TLR2 agonism activated luminal ECs, and deficiency of this innate immune receptor decreased intimal neutrophil adherence in regions of local flow disturbance, reducing EC injury and local thrombosis (p<0.05). Conclusions These results implicate flow disturbance, neutrophils, and TLR2 signaling as mechanisms that contribute to superficial erosion, a cause of ACS of likely growing importance in the statin era. PMID:28428204
NASA Technical Reports Server (NTRS)
Geer, Richard D.
1989-01-01
An electrochemical microbial check valve method (EC-MCV) for controlling the iodine disinfectant in potable water (PW) for NASA's space operations was proposed. The factors affecting the design and performance of the unit were analyzed. This showed that it would be feasible to construct a recyclable unit in a small volume that will operate in either an iodine removal or addition mode. The EC-MCV should remove active iodine species rapidly from PW, but the rapid delivery rates at end-use may make complete removal of excess I(-) difficult under some conditions. Its performace change with AgI buildup needs to be investigated, as this controls the time for recycling the unit. The EC-MCV has advantages over the passive microbial check valve (MCV) method currently in use, as it would allow precise control of the I2 level and would not introduce excess I(-) to the water. The presence of oxygen in the EC-MCV needs to be investigated as it could affect the efficiency of I2 addition and excess I(-) removal.
Zou, Haiming; Wang, Yan
2017-07-01
A new process of electrolysis cell (EC) coupled with microbial fuel cell (MFC) was developed here and its feasibility in methyl red (MR) wastewater treatment and simultaneous electricity generation was assessed. Results indicate that an excellent MR removal and electricity production performance was achieved, where the decolorization and COD removal efficiencies were 100% and 89.3%, respectively and a 0.56V of cell voltage output was generated. Electrolysis voltage showed a positive influence on decolorization rate (DR) but also cause a rapid decrease in current efficiency (CE). Although a low COD removal rate of 38.5% was found in EC system, biodegradability of MR solution was significantly enhanced, where the averaged DR was 85.6%. Importantly, COD removal rate in EC-MFC integrated process had a 50.8% improvement compared with the single EC system. The results obtained here would be beneficial to provide a prospective alternative for azo dyes wastewater treatment and power production. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nguyen, D Duc; Ngo, H Hao; Guo, W; Nguyen, T Thanh; Chang, Soon W; Jang, A; Yoon, Yong S
2016-09-01
This paper evaluated a novel pilot scale electrocoagulation (EC) system for improving total phosphorus (TP) removal from municipal wastewater. This EC system was operated in continuous and batch operating mode under differing conditions (e.g. flow rate, initial concentration, electrolysis time, conductivity, voltage) to evaluate correlative phosphorus and electrical energy consumption. The results demonstrated that the EC system could effectively remove phosphorus to meet current stringent discharge standards of less than 0.2mg/L within 2 to 5min. This target was achieved in all ranges of initial TP concentrations studied. It was also found that an increase in conductivity of solution, voltages, or electrolysis time, correlated with improved TP removal efficiency and reduced specific energy consumption. Based on these results, some key economic considerations, such as operating costs, cost-effectiveness, product manufacturing feasibility, facility design and retrofitting, and program implementation are also discussed. This EC process can conclusively be highly efficient in a relatively simple, easily managed, and cost-effective for wastewater treatment system. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Cho, Inhee; Huh, Keon; Kwak, Rhokyun; Lee, Hyomin; Kim, Sung Jae
2016-11-01
The first direct chronopotentiometric measurement was provided to distinguish the potential difference through the extended space charge (ESC) layer which is formed with the electrical double layer (EDL) near a perm-selective membrane. From this experimental result, the linear relationship was obtained between the resistance of ESC and the applied current density. Furthermore, we observed the step-wise distributions of relaxation time at the limiting current regime, confirming the existence of ESC capacitance other than EDL's. In addition, we proposed the equivalent electrokinetic circuit model inside ion concentration polarization (ICP) layer under rigorous consideration of EDL, ESC and electro-convection (EC). In order to elucidate the voltage configuration in chronopotentiometric measurement, the EC component was considered as the "dependent voltage source" which is serially connected to the ESC layer. This model successfully described the charging behavior of the ESC layer with or without EC, where both cases determined each relaxation time, respectively. Finally, we quantitatively verified their values utilizing the Poisson-Nernst-Planck equations. Therefore, this unified circuit model would provide a key insight of ICP system and potential energy-efficient applications.
Conductivity tomography based on pulsed eddy current with SQUID magnetometer
NASA Astrophysics Data System (ADS)
Panaitov, G. I.; Krause, H.-J.; Zhang, Y.
2002-05-01
Pulsed eddy current (EC) techniques have the advantage of potentially covering a broader depth range than standard single frequency EC testing. We developed a novel pulsed EC technique using a liquid-nitrogen cooled SQUID magnetometer. For two reasons, SQUID magnetometers are particularly well suited as sensors: first they constitute an extremely sensitive magnetic field sensor, second they measure the field directly which decays more slowly than its time derivative picked up by induction coils. A square waveform transmitter signal was used, with alternating slopes in order to eliminate drift effect, and stacking synchronous to the power line frequency in order to improve signal-to-noise. The early time (high frequency) data of the recorded transient correspond to the upper layers of the conducting medium, while late time data or low frequencies deliver information on deep layers. Measurements of cracks at different depths in a stacked aluminum sample are presented. From the measured data, the apparent conductivity of the sample was calculated for each position and depth by applying a technique known from geophysical data interpretation. Thus, the position and depth of the crack was determined from the tomographic conductivity image of the sample.
Purification and detoxification of petroleum refinery wastewater by electrocoagulation process.
Gousmi, N; Sahmi, A; Li, H Z; Poncin, S; Djebbar, R; Bensadok, K
2016-09-01
The treatment of synthetic oily wastewater having the characteristics of a typical petroleum refinery wastewater (PRW) by electrocoagulation (EC) using iron and aluminum electrodes was conducted in an electrolytic reactor equipped with fluid recirculation. During the treatment, the emulsion stability was followed by the measurement of Zeta potential and particle sizes. Effects of some operating conditions such as electrodes material, current density and electrolysis time on removal efficiencies of turbidity, and chemical oxygen demand (COD) were investigated in detail. The PRW purification by the EC process was found to be the most effective using aluminum as the anode and cathode, current density of 60 A/m(2) and 30 min of electrolysis time. Under these conditions, the process efficiencies were 83.52% and 99.94%, respectively, for COD and turbidity removals which correspond to final values of 96 mg O2/L and 0.5 NTU. A moderate energy consumption (0.341 kWh) was needed to treat 1 m(3) of PRW. Besides, the ecotoxicity test proved that toxic substances presented in the PRW, and those inhibiting the germination growth of whet, were eliminated by the EC technique.