Sample records for current injection dci

  1. Development of an efficient fractionation method for the preparative separation of sesquiterpenoids from Tussilago farfara by counter-current chromatography.

    PubMed

    Song, Kwangho; Lee, Kyoung Jin; Kim, Yeong Shik

    2017-03-17

    A novel application of counter-current chromatography (CCC) to enrich plant extracts using direct and continuous injection (CCC-DCI) was developed to fractionate sesquiterpenoids from the buds of Tussilago farfara L. In this study, an n-hexane-acetonitrile-water (HAcW) solvent system was separately pumped into the CCC column, and an extraction solution (45% acetonitrile) was directly and continuously injected into the CCC column. Since the extraction solution was used as a mobile phase in this method, solvent consumption could be greatly reduced. To enrich the extraction solution (315.9g/5.4L), only 4.2L water, 4.6L acetonitrile, and 1.2L n-hexane were used, including the extraction step. Finally, 6.8g of a sesquiterpenoid-enriched (STE) fraction was obtained from the crude extract (315.9g) of Tussilago farfara (1kg) in a single CCC run with a separation time of 8.5h. The sample injection capacity of CCC-DCI was greater than 300g; this amount of sample could not be handled in conventional CCC or other fractionation methods with the same column volume. Moreover, three major sesquiterpenoids (1: tussilagone, 2: 14-acetoxy-7β-(3'-ethyl cis-crotonoyloxy)-1α-(2'-methylburyryloxy)-notonipetranone, and 3: 7β-(3'-ethyl cis-crotonoyloxy)-1α-(2'-methylburyryloxy)-3, 14-dehydro-Z-notonipetranone) were purified from the STE fraction by CCC, and their chemical structures were elucidated by 1 H NMR and 13 C NMR. A quantification study was conducted, and the contents of compounds 1-3 in the CCC-DCI fraction were higher than those of conventional multi-step fractionations performed in series: solvent partitioning and open column chromatography. Furthermore, the average CCC-DCI recoveries were 96.1% (1), 96.9% (2), and 94.6% (3), whereas the open column chromatography recoveries were 77.7% (1), 66.5% (2), and 58.4% (3). The developed method demonstrates that CCC is a useful technique for enriching target components from natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Decompression illness secondary to occupational diving: recommended management based current legistation and practice in Malaysia.

    PubMed

    Rozali, A; Khairuddin, H; Sherina, M S; Zin, B Mohd; Sulaiman, A

    2008-06-01

    Occupational divers are exposed to hazards which contribute to the risk of developing decompression illnesses (DCI). DCI consists of Type I decompression sickness (DCS), Type II DCS and arterial gas embolism (AGE), developed from formation of bubbles in the tissues or circulation as a result of inadequate elimination of inert gas (nitrogen) after a dive. In Malaysia, DCI is one of the significant contributions to mortality and permanent residual morbidity in diving accidents. This is a case of a diver who suffered from Type II DCS with neurological complications due to an occupational diving activity. This article mentions the clinical management of the case and makes several recommendations based on current legislations and practise implemented in Malaysia in order to educate medical and health practitioners on the current management of DCI from the occupational perspective. By following these recommendations, hopefully diving accidents mainly DCI and its sequalae among occupational divers can be minimized and prevented, while divers who become injured receive the proper compensation for their disabilities.

  3. Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coddington, M. H.; Kroposki, B. D.; Basso, T.

    In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizesmore » current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.« less

  4. Calorie intake and patient outcomes in severe acute kidney injury: findings from The Randomized Evaluation of Normal vs. Augmented Level of Replacement Therapy (RENAL) study trial

    PubMed Central

    2014-01-01

    Introduction Current practice in the delivery of caloric intake (DCI) in patients with severe acute kidney injury (AKI) receiving renal replacement therapy (RRT) is unknown. We aimed to describe calorie administration in patients enrolled in the Randomized Evaluation of Normal vs. Augmented Level of Replacement Therapy (RENAL) study and to assess the association between DCI and clinical outcomes. Methods We performed a secondary analysis in 1456 patients from the RENAL trial. We measured the dose and evolution of DCI during treatment and analyzed its association with major clinical outcomes using multivariable logistic regression, Cox proportional hazards models, and time adjusted models. Results Overall, mean DCI during treatment in ICU was low at only 10.9 ± 9 Kcal/kg/day for non-survivors and 11 ± 9 Kcal/kg/day for survivors. Among patients with a lower DCI (below the median) 334 of 729 (45.8%) had died at 90-days after randomization compared with 316 of 727 (43.3%) patients with a higher DCI (above the median) (P = 0.34). On multivariable logistic regression analysis, mean DCI carried an odds ratio of 0.95 (95% confidence interval (CI): 0.91-1.00; P = 0.06) per 100 Kcal increase for 90-day mortality. DCI was not associated with significant differences in renal replacement (RRT) free days, mechanical ventilation free days, ICU free days and hospital free days. These findings remained essentially unaltered after time adjusted analysis and Cox proportional hazards modeling. Conclusions In the RENAL study, mean DCI was low. Within the limits of such low caloric intake, greater DCI was not associated with improved clinical outcomes. Trial registration ClinicalTrials.gov number, NCT00221013 PMID:24629036

  5. Validation of the Dyadic Coping Inventory with Chinese couples: Factorial structure, measurement invariance, and construct validity.

    PubMed

    Xu, Feng; Hilpert, Peter; Randall, Ashley K; Li, Qiuping; Bodenmann, Guy

    2016-08-01

    The Dyadic Coping Inventory (DCI, Bodenmann, 2008) assesses how couples support each other when facing individual (e.g., workload) and common (e.g., parenting) stressors. Specifically, the DCI measures partners' perceptions of their own (Self) and their partners' behaviors (Partner) when facing individual stressors, and partners' common coping behaviors when facing common stressors (Common). To date, the DCI has been validated in 6 different languages from individualistic Western cultures; however, because culture can affect interpersonal interactions, it is unknown whether the DCI is a reliable measure of coping behaviors for couples living in collectivistic Eastern cultures. Based on data from 474 Chinese couples (N = 948 individuals), the current study examined the Chinese version of the DCI's factorial structure, measurement invariance (MI), and construct validity of test scores. Using 3 cultural groups (China, Switzerland, and the United States [U.S.]), confirmatory factor analysis revealed a 5-factor structure regarding Self and Partner and a 2-factor structure regarding Common dyadic coping (DC). Results from analyses of MI indicated that the DCI subscales met the criteria for configural, metric, and full/partial scalar invariance across cultures (Chinese-Swiss and Chinese-U.S.) and genders (Chinese men and women). Results further revealed good construct validity of the DCI test scores. In all, the Chinese version of the DCI can be used for measuring Chinese couples' coping behaviors, and is available for cross-cultural studies examining DC behaviors between Western and Eastern cultures. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. Milrinone via lumbar subarachnoid catheter for vasospasm after aneurysmal subarachnoid hemorrhage.

    PubMed

    Sadamasa, Nobutake; Yoshida, Kazumichi; Narumi, Osamu; Chin, Masaki; Yamagata, Sen

    2014-12-01

    Delayed ischemic neurological deficit (DIND) due to symptomatic vasospasm is a major cause of morbidity and mortality after aneurysmal subarachnoid hemorrhage (aSAH). The aim of this study was to elucidate the safety and feasibility of intrathecal milrinone infusion via lumber subarachnoid catheter for prevention of DIND after aSAH. We diagnosed 425 consecutive patients with aSAH who received clipping or coil embolization within 48 h after arrival. Patients with the evidence of vasospasm on CT angiography (CTA) received the milrinone therapy via lumbar subarachnoid catheter. DIND, delayed cerebral infarction (DCI), and modified Rankin scale at 3 months after SAH were used for the assessment of outcome. Of 425 patients, 170 patients (40.0 %) with CTA-proven vasospasm received the milrinone therapy. DIND was observed in 68 patients (16.0 %), DCI in 30 patients (7.1 %), and the overall mortality was 7.2 %. In patients with WFNS grade IV and V aSAH, 26 out of 145 patients (17.9 %) were presented with DIND, 12 (8.3 %) with DCI, and the mortality was 16.0 %. No major complication related to the milrinone injection was observed. Intrathecal milrinone injection via lumbar catheter was safe and feasible, and further randomized prospective studies are needed to confirm the effectiveness of this regimen in the patients with SAH.

  7. Peer victimization and subjective health among students reporting disability or chronic illness in 11 Western countries.

    PubMed

    Sentenac, Mariane; Gavin, Aoife; Gabhainn, Saoirse Nic; Molcho, Michal; Due, Pernille; Ravens-Sieberer, Ulrike; Matos, Margarida Gaspar de; Malkowska-Szkutnik, Agnieszka; Gobina, Inese; Vollebergh, Wilma; Arnaud, Catherine; Godeau, Emmanuelle

    2013-06-01

    To compare the strength of the association between peer victimization at school and subjective health according to the disability or chronic illness (D/CI) status of students across countries. This study used data from 55 030 students aged 11, 13 and 15 years from 11 countries participating in the 2005-06 Health Behaviour in School-aged Children survey. Self-completed questionnaires were administered in classrooms. Multivariate models of logistic regression (controlled for confounding factors and countries) were used to investigate differences in the association between peer victimization and poor subjective health according to the D/CI status. Overall, 13.5% of the students reported having been bullied at least two or three times a month. The percentage of victims was significantly higher among those reporting D/CI than among others in all countries studied. Victims of bullying were more likely to report poor self-rated health, low life satisfaction and multiple health complaints. However, there were no differences in the associations between peer victimization and subjective health indicators according to the D/CI status. In all countries studied, students reporting D/CI were more likely to report being victims of bullying. Victims of bullying reported more negative subjective health outcomes regardless of their D/CI status. Although inclusive education is currently a major topic of educational policies in most countries, additional efforts should be made to improve the quality of the integration of students with D/CI.

  8. Management of delayed cerebral ischemia after subarachnoid hemorrhage.

    PubMed

    Francoeur, Charles L; Mayer, Stephan A

    2016-10-14

    For patients who survive the initial bleeding event of a ruptured brain aneurysm, delayed cerebral ischemia (DCI) is one of the most important causes of mortality and poor neurological outcome. New insights in the last decade have led to an important paradigm shift in the understanding of DCI pathogenesis. Large-vessel cerebral vasospasm has been challenged as the sole causal mechanism; new hypotheses now focus on the early brain injury, microcirculatory dysfunction, impaired autoregulation, and spreading depolarization. Prevention of DCI primarily relies on nimodipine administration and optimization of blood volume and cardiac performance. Neurological monitoring is essential for early DCI detection and intervention. Serial clinical examination combined with intermittent transcranial Doppler ultrasonography and CT angiography (with or without perfusion) is the most commonly used monitoring paradigm, and usually suffices in good grade patients. By contrast, poor grade patients (WFNS grades 4 and 5) require more advanced monitoring because stupor and coma reduce sensitivity to the effects of ischemia. Greater reliance on CT perfusion imaging, continuous electroencephalography, and invasive brain multimodality monitoring are potential strategies to improve situational awareness as it relates to detecting DCI. Pharmacologically-induced hypertension combined with volume is the established first-line therapy for DCI; a good clinical response with reversal of the presenting deficit occurs in 70 % of patients. Medically refractory DCI, defined as failure to respond adequately to these measures, should trigger step-wise escalation of rescue therapy. Level 1 rescue therapy consists of cardiac output optimization, hemoglobin optimization, and endovascular intervention, including angioplasty and intra-arterial vasodilator infusion. In highly refractory cases, level 2 rescue therapies are also considered, none of which have been validated. This review provides an overview of current state-of-the-art care for DCI management.

  9. Polycystic Ovary Syndrome: Insights into the Therapeutic Approach with Inositols

    PubMed Central

    Sortino, Maria A.; Salomone, Salvatore; Carruba, Michele O.; Drago, Filippo

    2017-01-01

    Polycystic ovary syndrome (PCOS) is characterized by hormonal abnormalities that cause menstrual irregularity and reduce ovulation rate and fertility, associated to insulin resistance. Myo-inositol (cis-1,2,3,5-trans-4,6-cyclohexanehexol, MI) and D-chiro-inositol (cis-1,2,4-trans-3,5,6-cyclohexanehexol, DCI) represent promising treatments for PCOS, having shown some therapeutic benefits without substantial side effects. Because the use of inositols for treating PCOS is widespread, a deep understanding of this treatment option is needed, both in terms of potential mechanisms and efficacy. This review summarizes the current knowledge on the biological effects of MI and DCI and the results obtained from relevant intervention studies with inositols in PCOS. Based on the published results, both MI and DCI represent potential valid therapeutic approaches for the treatment of insulin resistance and its associated metabolic and reproductive disorders, such as those occurring in women affected by PCOS. Furthermore, the combination MI/DCI seems also effective and might be even superior to either inositol species alone. However, based on available data, a particular MI:DCI ratio to be administered to PCOS patients cannot be established. Further studies are then necessary to understand the real contents of MI or DCI uptaken by the ovary following oral administration in order to identify optimal doses and/or combination ratios. PMID:28642705

  10. Burkholderia ginsengiterrae sp. nov. and Burkholderia panaciterrae sp. nov., antagonistic bacteria against root rot pathogen Cylindrocarpon destructans, isolated from ginseng soil.

    PubMed

    Farh, Mohamed El-Agamy; Kim, Yeon-Ju; Van An, Hoang; Sukweenadhi, Johan; Singh, Priyanka; Huq, Md Amdadul; Yang, Deok-Chun

    2015-04-01

    Strain DCY85(T) and DCY85-1(T), isolated from rhizosphere of ginseng, were rod-shaped, Gram-reaction-negative, strictly aerobic, catalase positive and oxidase negative. 16S rRNA gene sequence analysis revealed that strain DCY85(T) as well as DCY85-1(T) belonged to the genus Burkholderia and were closely related to Burkholderia fungorum KACC 12023(T) (98.1 and 98.0 % similarity, respectively). The major polar lipids of strain DCY85(T) and DCY85-1(T) were phosphatidylethanolamine, one unidentified aminolipid and two unidentified phospholipids. The major fatty acids of both strains are C16:0, C18:1 ω7c and summed feature 3 (C16:1 ω6c and/or C16:1 ω7c). The predominant isoprenoid quinone of each strain DCY85(T) and DCY85-1(T) was ubiquinone (Q-8) and the G+C content of their genomic DNA was 66.0 and 59.4 mol%, respectively, which fulfill the characteristic range of the genus Burkholderia. The polyamine content of both DCY85(T) and DCY85-1(T) was putrescine. Although both DCY85(T) and DCY85-1(T) have highly similar 16S rRNA and identical RecA and gyrB sequences, they show differences in phenotypic and chemotaxonomic characteristics. DNA-DNA hybridization results proved the consideration of both strains as two different species. Based on the results from our polyphasic characterization, strain DCY85(T) and DCY85-1(T) are considered novel Burkholderia species for which the name Burkholderia ginsengiterrae sp. nov and Burkholderia panaciterrae sp. nov are, respectively, proposed. An emended description of those strains is also proposed. DCY85(T) and DCY85-1(T) showed antagonistic activity against the common root rot pathogen of ginseng, Cylindrocarpon destructans. The proposed type strains are DCY85(T) (KCTC 42054(T) = JCM 19888(T)) and DCY85-1(T) (KCTC 42055(T) = JCM 19889(T)).

  11. List of Participants

    NASA Astrophysics Data System (ADS)

    2011-08-01

    Abigail Alvarez OlarteCINVESTAV Alba Leticia Carrillo MonteverdeDCI-UG Alberto CarramiñanaINAOE Aldo MorselliFERMI Alejandro CastillaDCI-UG Alejandro IbarraTechnical University of Munich Alma D Rojas PachecoFCFM-BUAP Alma Xochitl Gonzalez MoralesInstituto de Ciencias Nucleares, UNAM Andrew Walcott BeckwithAmerican Institute of Beam Energy Physics Ariadna Montiel ArenasDepartamento de Física, CINVESTAV Arnulfo ZepedaCinvestav Arturo Alvarez CruzInstituto de Fisica, UNAM Axel de la MacorraUNAM, IAC Azar MustafayevUniversity of Minnesota Benjamin JaramilloDCI-UG Vincent BertinCPPM-Marseille Carlos Alberto Vaquera-AraujoDCI-UG Carlos MuñozMadrid Autonoma U. & Madrid, IFT Carmine PagliaroneINFN, FNAL Carolina Lujan PeschardDCI-UG Christiane Frigerio MartinsUniversidade Federal do ABC-São Paulo Csaba BalazsMonash University David DelepineDCI-UG David G CerdenoUniversidad Autonoma de Madrid & Instituto de Fisica Teorica Debasish MajumdarSaha Institute of Nuclear Physics, Kolkata, India Dibyendu PanigrahiKandi Raj College, Kandi, Murshidabad, INDIA-742137 Dupret Alberto Santana BejaranoUniversidad de Sonora Departamento de Investigacion en Fisica Ernest MaRiverside U.C. Esteban Alejandro Reyes Pírez MontañezInstituto de Física, UNAM Federico Ortiz TrejoINSTITUTO DE ASTRONOMÍA - UNAM Francisco José de Anda NavarroUniversidad de Guadalajara González Alvarez Francisco JavierCINVESTAV-Depto. Física Gustavo Medina TancoICN-UNAM Hernando Efrain Caicedo OrtizInstituto Politecnico Nacional - IPN J D VergadosCERN & Ioannina U. James R BoyceJefferson Lab Jason SteffenFERMILAB Javier Montaño DomínguezDCI-UG Jeevan SolankiMandsaur Institue of Technology MP India Joe SatoSaitama University Jorge Luis Navarro EstradaUNAM-ICN and Universidad del Atlantico (B/quilla-Col.) Jose A R CembranosUniversity of Minnesota José DíazIFIC Jose Didino Garcia AguilarDepto. de Fisica. Cinvestav Keith OliveUniversity of Minnesota Konstantia BalasiUniversity of Ioannina, Greece Lilian Prado GonzalezBUAP, FCFM Lorenzo Díaz CruzBUAP Facultad de Ciencias Físico Matemáticas Luis Rey Díaz BarrónDivisión de Ciencias e Ingenierías Luis UrenaUniversidad de Guanajuato Magda LolaDept. of Physics, University of Patras, Greece Mahmoud WahbaEgyptian Center for Theoretical Physics, MTI Marcus S CohenNew Mexico State University Mario A Acero OrtegaICN - UNAM Mario E GomezUniversidad de Huelva Mark PipeUniversity of Sheffield Mauro NapsucialeDCI-UG Mirco CannoniUniversidad de Huelva Mónica Felipa Ramírez PalaciosUniversidad de Guadalajara Murli Manohar VermaLucknow university, India Nassim BozorgniaUCLA Octavio Obregón Octavio ValenzuelaIA-UNAM Oleg KamaevUniversity of Minnesota Osamu SetoHokkai-Gakuen University Pedro F González DíazIFF, CSIC, Serrano 121, 28006 Madrid, Spain Qaisar ShafiBartol Research Inst. and Delaware U. Raul Hennings-YeomansLos Alamos National Laboratory René Ángeles MartínezDepartamento de Fisica, del DCI de la Universidad de Guanajuato Reyna XoxocotziBUAP, FCFM Rishi Kumar TiwariGovt. Model Science College, Rewa (MP) INDIA Roberto A SussmanICN-UNAM Selim Gómez ÁvilaDCI-UG Sugai KenichiSaitama University Susana Valdez AlvaradoDCI-UG TVladimir - 2K CollaborationColorado State University Tonatiuh MatosCINVESTAV Valeriy DvoeglazovUniversidad de Zacatecas Vannia Gonzalez MaciasDCI-UG Vladimir Avila-ReeseInstituto de Astronomia, UNAM Wolfgang BietenholzINC, UNAM (Mexico) Yamanaka MasatoKyoto Sangyo University Yann MambriniLPT Orsay Yu-Feng ZhouInstitute of Theotretical Physics, Chinese Academy of Sciences, PR China Aaron HigueraDCI-UG Azarael Yebra PérezDCI-UG César Hernández AguayoDCI-UG Jaime Chagoya AlvarezDCI-UG Jonathan Rashid Rosique CampuzanoDCI-UG José Alfredo Soto ÁlvarezDCI-UG Juan Carlos De Haro SantosDCI-UG Luis Eduardo Medina MedranoDCI-UG Maria Fatima Rubio EspinozaDCI-UG Paulo Alberto Rodriguez HerreraDCI-UG Roberto Oziel Gutierrez CotaDCI-UG Rocha Moran Maria PaulinaDCI-UG Xareni Sanchez MonroyDCI-UG

  12. Microstructure and Sliding Wear Behaviour of In-Situ TiC-Reinforced Composite Surface Layers Fabricated on Ductile Cast Iron by Laser Alloying.

    PubMed

    Janicki, Damian

    2018-01-05

    TiC-reinforced composite surface layers (TRLs) on a ductile cast iron EN-GJS-700-2 grade (DCI) substrate were synthesized using a diode laser surface alloying with a direct injection of titanium powder into the molten pool. The experimental results were compared with thermodynamic calculations. The TRLs having a uniform distribution of the TiC particles and their fraction up to 15.4 vol % were achieved. With increasing titanium concentration in the molten pool, fractions of TiC and retained austenite increase and the shape of TiC particles changes from cubic to dendritic form. At the same time, the cementite fraction decreases, lowering the overall hardness of the TRL. A good agreement between experimental and calculated results was achieved. Comparative dry sliding wear tests between the as-received DCI, the TRLs and also laser surface melted layers (SMLs) have been performed following the ASTM G 99 standard test method under contact pressures of 2.12 and 4.25 MPa. For both the as-received DCI and the SMLs, the wear rates increased with increasing contact pressure. The TRLs exhibited a significantly higher wear resistance than the others, which was found to be load independent.

  13. Microstructure and Sliding Wear Behaviour of In-Situ TiC-Reinforced Composite Surface Layers Fabricated on Ductile Cast Iron by Laser Alloying

    PubMed Central

    Janicki, Damian

    2018-01-01

    TiC-reinforced composite surface layers (TRLs) on a ductile cast iron EN-GJS-700-2 grade (DCI) substrate were synthesized using a diode laser surface alloying with a direct injection of titanium powder into the molten pool. The experimental results were compared with thermodynamic calculations. The TRLs having a uniform distribution of the TiC particles and their fraction up to 15.4 vol % were achieved. With increasing titanium concentration in the molten pool, fractions of TiC and retained austenite increase and the shape of TiC particles changes from cubic to dendritic form. At the same time, the cementite fraction decreases, lowering the overall hardness of the TRL. A good agreement between experimental and calculated results was achieved. Comparative dry sliding wear tests between the as-received DCI, the TRLs and also laser surface melted layers (SMLs) have been performed following the ASTM G 99 standard test method under contact pressures of 2.12 and 4.25 MPa. For both the as-received DCI and the SMLs, the wear rates increased with increasing contact pressure. The TRLs exhibited a significantly higher wear resistance than the others, which was found to be load independent. PMID:29304001

  14. Effect on Insulin-Stimulated Release of D-Chiro-Inositol-Containing Inositolphosphoglycan Mediator during Weight Loss in Obese Women with and without Polycystic Ovary Syndrome.

    PubMed

    Cheang, Kai I; Sistrun, Sakita N; Morel, Kelley S; Nestler, John E

    2016-01-01

    Background. A deficiency of D-chiro-inositol-inositolphosphoglycan mediator (DCI-IPG) may contribute to insulin resistance in polycystic ovary syndrome (PCOS). Whether the relationship between impaired DCI-IPG release and insulin resistance is specific to PCOS rather than obesity is unknown. We assessed insulin-released DCI-IPG and its relationship to insulin sensitivity at baseline and after weight loss in obese women with and without PCOS. Methods. Obese PCOS ( n = 16) and normal ( n = 15) women underwent 8 weeks of a hypocaloric diet. The Matsuda index, area under the curve DCI-IPG (AUC DCI-IPG ), AUC insulin , and AUC DCI-IPG /AUC insulin were measured during a 2 hr OGTT at baseline and 8 weeks. Results. PCOS women had lower AUC DCI-IPG /AUC insulin at baseline and a significant relationship between AUC DCI-IPG /AUC insulin and Matsuda index ( p = 0.0003), which was not present in controls. Weight loss was similar between PCOS (-4.08 kg) and normal women (-4.29 kg, p = 0.6281). Weight loss in PCOS women did not change the relationship between AUC DCI-IPG /AUC insulin and Matsuda index ( p = 0.0100), and this relationship remained absent in control women. Conclusion. The association between AUC DCI-IPG /AUC insulin and insulin sensitivity was only found in PCOS but not in normal women, and this relationship was unaffected by weight loss. DCI and its messenger may contribute to insulin resistance in PCOS independent of obesity.

  15. Patent foramen ovale influences the presentation of decompression illness in SCUBA divers.

    PubMed

    Liou, Kevin; Wolfers, Darren; Turner, Robert; Bennett, Michael; Allan, Roger; Jepson, Nigel; Cranney, Greg

    2015-01-01

    Few have examined the influence of patent foramen ovale (PFO) on the phenotype of decompression illness (DCI) in affected divers. A retrospective review of our database was performed for 75 SCUBA divers over a 10-year period. Overall 4,945 bubble studies were performed at our institution during the study period. Divers with DCI were more likely to have positive bubble studies than other indications (p<0.001). Major DCI was observed significantly more commonly in divers with PFO than those without (18/1,000 v.s. 3/1,000, p=0.02). Divers affected by DCI were also more likely to require a longer course of hyperbaric oxygen therapy (HBOT) if PFO was present (p=0.038). If the patient experienced one or more major DCI symptoms, the odds ratio of PFO being present on a transoesophageal echocardiogram was 3.2 (p=0.02) compared to those who reported no major DCI symptoms. PFO is highly prevalent in selected SCUBA divers with DCI, and is associated with a more severe DCI phenotype and longer duration of HBOT. Patients with unexpected DCI with one or more major DCI symptoms should be offered PFO screening if they choose to continue diving, as it may have considerable prognostic and therapeutic implications. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  16. Management of delayed cerebral ischemia after subarachnoid hemorrhage.

    PubMed

    Koenig, Matthew A

    2012-06-01

    The purpose of this article is to describe the modern management of delayed cerebral ischemia (DCI) in patients with aneurysmal subarachnoid hemorrhage (SAH). SAH causes an inflammatory reaction to blood products in the basal cisterns of the brain, which may produce cerebral ischemia and strokes through progressive narrowing of the cerebral artery lumen. This process, known as cerebral vasospasm, is the most common cause of DCI after SAH. Untreated DCI may result in strokes, which account for a significant portion of the death and long-term disability after SAH. A number of publications, including two recent consensus statements, have clarified many best practices for defining, diagnosing, monitoring, preventing, and treating DCI. DCI is best defined as new onset of focal or global neurologic deficits or strokes not attributable to another cause. In addition to the clinical examination, radiographic studies such as transcranial Doppler ultrasonography, CT angiography, and CT perfusion may have a role in determining which patients are at high risk for developing DCI. The mainstay of prevention and treatment of DCI is maintenance of euvolemia, which can be a difficult therapeutic target to measure. Hemodynamic augmentation with induced hypertension with or without inotropic support has become the first-line treatment of DCI. The ideal method of measuring hemodynamic values and volume status in patients with DCI remains elusive. In patients who do not adequately respond to or cannot tolerate hemodynamic augmentation, endovascular therapy (intraarterial vasodilators and balloon angioplasty) is a complementary strategy. Optimal triggers for escalation and de-escalation of therapies for DCI have not been well defined. Recent guidelines and consensus statements have clarified many aspects of prevention, monitoring, and treatment of DCI after SAH. Controversies continue regarding the optimal methods for measurement of volume status, the role of invasive neuromonitoring, and the targets for hemodynamic augmentation therapy.

  17. Relationship of the time course of venous gas bubbles to altitude decompression illness

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Foster, P. P.; Powell, M. R.; Waligora, J. M.

    1996-01-01

    The correlation is low between the occurrence of gas bubbles in the pulmonary artery, called venous gas emboli (VGE), and subsequent decompression illness (DCI). The correlation improves when a "grade" of VGE is considered; a zero to four categorical classification based on the intensity and duration of the VGE signal from a Doppler bubble detector. Additional insight about DCI might come from an analysis of the time course of the occurrence of VGE. Using the NASA Hypobaric Decompression Sickness Databank, we compared the time course of the VGE outcome between 322 subjects who exercised and 133 Doppler technicians who did not exercise to evaluate the role of physical activity on the VGE outcome and incidence of DCI. We also compared 61 subjects with VGE and DCI with 110 subjects with VGE but without DCI to identify unique characteristics about the time course of the VGE outcome to try to discriminate between DCI and no-DCI cases. The VGE outcome as a function of time showed a characteristic short lag, rapid response, and gradual recovery phase that was related to physical activity at altitude and the presence or absence of DCI. The average time for DCI symptoms in a limb occurred just before the time of the highest fraction of VGE in the pulmonary artery. It is likely, but not certain, that an individual will report a DCI symptom if VGE are detected early in the altitude exposure, the intensity or grade of VGE rapidly increases from a limb region, and the intensity or grade of VGE remains high.

  18. Effectiveness of diagnostic strategies in suspected delayed cerebral ischemia: a decision analysis.

    PubMed

    Rawal, Sapna; Barnett, Carolina; John-Baptiste, Ava; Thein, Hla-Hla; Krings, Timo; Rinkel, Gabriel J E

    2015-01-01

    Delayed cerebral ischemia (DCI) is a serious complication after aneurysmal subarachnoid hemorrhage. If DCI is suspected clinically, imaging methods designed to detect angiographic vasospasm or regional hypoperfusion are often used before instituting therapy. Uncertainty in the strength of the relationship between imaged vasospasm or perfusion deficits and DCI-related outcomes raises the question of whether imaging to select patients for therapy improves outcomes in clinical DCI. Decision analysis was performed using Markov models. Strategies were either to treat all patients immediately or to first undergo diagnostic testing by digital subtraction angiography or computed tomography angiography to assess for angiographic vasospasm, or computed tomography perfusion to assess for perfusion deficits. According to current practice guidelines, treatment consisted of induced hypertension. Outcomes were survival in terms of life-years and quality-adjusted life-years. When treatment was assumed to be ineffective in nonvasospasm patients, Treat All and digital subtraction angiography were equivalent strategies; when a moderate treatment effect was assumed in nonvasospasm patients, Treat All became the superior strategy. Treating all patients was also superior to selecting patients for treatment via computed tomography perfusion. One-way sensitivity analyses demonstrated that the models were robust; 2- and 3-way sensitivity analyses with variation of disease and treatment parameters reinforced dominance of the Treat All strategy. Imaging studies to test for the presence of angiographic vasospasm or perfusion deficits in patients with clinical DCI do not seem helpful in selecting which patients should undergo treatment and may not improve outcomes. Future directions include validating these results in prospective cohort studies. © 2014 American Heart Association, Inc.

  19. Novel management strategies for medically-refractory vasospasm following aneurysmal subarachnoid hemorrhage.

    PubMed

    Al-Mufti, Fawaz; Amuluru, Krishna; Damodara, Nitesh; El-Ghanem, Mohammad; Nuoman, Rolla; Kamal, Naveed; Al-Marsoummi, Sarmad; Morris, Nicholas A; Dangayach, Neha S; Mayer, Stephan A

    2018-07-15

    Delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (SAH) is an important cause of further morbidity and mortality after an already devastating condition. Though traditionally attributed to vasospasm of large capacitance arteries and the resulting down-stream disruption of cerebral blood flow, the pathogenesis of DCI has proven to be more complex with early brain injury, blood-brain barrier disruption, microthrombosis, cortical spreading depolarizations, and the failure of cerebral autoregulation as newly elucidated factors. Vasospasm is a known consequence of SAH. The standard of care includes close monitoring for neurological deterioration, most often with serial clinical examinations, transcranial Doppler ultrasonography, and vascular imaging (crucial for early detection of DCI and allows for prompt intervention). Nimodipine continues to remain an important pharmacological strategy to improve functional outcomes in patients with SAH at risk for developing vasospasm. The paradigm for first line therapy in patients with vasospasm of induced hypertension, hypervolemia, and hemodilution has recently been challenged. Current American Heart Association guidelines recommend targeting euvolemia and judicious use of the pharmacologically induced hypertension component. Symptomatic vasospasm patients who do not improve with this first line therapy require rescue intervention with mechanical or chemical angioplasty and optimization of cardiac output and hemoglobin levels. This can be escalated in a step-wise fashion to include adjunct treatments such as intrathecal administration of vasodilators and sympatholytic or thrombolytic therapies. This review provides a general overview of the treatment modalities for DCI with a focus on novel management strategies that show promising results for treating vasospasm to prevent DCI. Copyright © 2018. Published by Elsevier B.V.

  20. Epileptiform abnormalities predict delayed cerebral ischemia in subarachnoid hemorrhage.

    PubMed

    Kim, J A; Rosenthal, E S; Biswal, S; Zafar, S; Shenoy, A V; O'Connor, K L; Bechek, S C; Valdery Moura, J; Shafi, M M; Patel, A B; Cash, S S; Westover, M B

    2017-06-01

    To identify whether abnormal neural activity, in the form of epileptiform discharges and rhythmic or periodic activity, which we term here ictal-interictal continuum abnormalities (IICAs), are associated with delayed cerebral ischemia (DCI). Retrospective analysis of continuous electroencephalography (cEEG) reports and medical records from 124 patients with moderate to severe grade subarachnoid hemorrhage (SAH). We identified daily occurrence of seizures and IICAs. Using survival analysis methods, we estimated the cumulative probability of IICA onset time for patients with and without delayed cerebral ischemia (DCI). Our data suggest the presence of IICAs indeed increases the risk of developing DCI, especially when they begin several days after the onset of SAH. We found that all IICA types except generalized rhythmic delta activity occur more commonly in patients who develop DCI. In particular, IICAs that begin later in hospitalization correlate with increased risk of DCI. IICAs represent a new marker for identifying early patients at increased risk for DCI. Moreover, IICAs might contribute mechanistically to DCI and therefore represent a new potential target for intervention to prevent secondary cerebral injury following SAH. These findings imply that IICAs may be a novel marker for predicting those at higher risk for DCI development. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  1. Gene expression profile of blood cells for the prediction of delayed cerebral ischemia after intracranial aneurysm rupture: a pilot study in humans.

    PubMed

    Baumann, Antoine; Devaux, Yvan; Audibert, Gérard; Zhang, Lu; Bracard, Serge; Colnat-Coulbois, Sophie; Klein, Olivier; Zannad, Faiez; Charpentier, Claire; Longrois, Dan; Mertes, Paul-Michel

    2013-01-01

    Delayed cerebral ischemia (DCI) is a potentially devastating complication after intracranial aneurysm rupture and its mechanisms remain poorly elucidated. Early identification of the patients prone to developing DCI after rupture may represent a major breakthrough in its prevention and treatment. The single gene approach of DCI has demonstrated interest in humans. We hypothesized that whole genome expression profile of blood cells may be useful for better comprehension and prediction of aneurysmal DCI. Over a 35-month period, 218 patients with aneurysm rupture were included in this study. DCI was defined as the occurrence of a new delayed neurological deficit occurring within 2 weeks after aneurysm rupture with evidence of ischemia either on perfusion-diffusion MRI, CT angiography or CT perfusion imaging, or with cerebral angiography. DCI patients were matched against controls based on 4 out of 5 criteria (age, sex, Fisher grade, aneurysm location and smoking status). Genome-wide expression analysis of blood cells obtained at admission was performed by microarrays. Transcriptomic analysis was performed using long oligonucleotide microarrays representing 25,000 genes. Quantitative PCR: 1 µg of total RNA extracted was reverse-transcribed, and the resulting cDNA was diluted 10-fold before performing quantitative PCR. Microarray data were first analyzed by 'Significance Analysis of Microarrays' software which includes the Benjamini correction for multiple testing. In a second step, microarray data fold change was compared using a two-tailed, paired t test. Analysis of receiver-operating characteristic (ROC) curves and the area under the ROC curves were used for prediction analysis. Logistic regression models were used to investigate the additive value of multiple biomarkers. A total of 16 patients demonstrated DCI. Significance Analysis of Microarrays software failed to retrieve significant genes, most probably because of the heterogeneity of the patients included in the microarray experiments and the small size of the DCI population sample. Standard two-tailed paired t test and C-statistic revealed significant associations between gene expression and the occurrence of DCI: in particular, the expression of neuroregulin 1 was 1.6-fold upregulated in patients with DCI (p = 0.01) and predicted DCI with an area under the ROC curve of 0.96. Logistic regression analyses revealed a significant association between neuroregulin 1 and DCI (odds ratio 1.46, 95% confidence interval 1.02-2.09, p = 0.02). This pilot study suggests that blood cells may be a reservoir of prognostic biomarkers of DCI in patients with intracranial aneurysm rupture. Despite an evident lack of power, this study elicited neuroregulin 1, a vasoreactivity-, inflammation- and angiogenesis-related gene, as a possible candidate predictor of DCI. Larger cohort studies are needed but genome-wide microarray-based studies are promising research tools for the understanding of DCI after intracranial aneurysm rupture. © 2013 S. Karger AG, Basel.

  2. Incidence of delayed seizures, delayed cerebral ischemia and poor outcome with the use of levetiracetam versus phenytoin after aneurysmal subarachnoid hemorrhage.

    PubMed

    Karamchandani, Rahul Ramesh; Fletcher, Jeffrey James; Pandey, Aditya Swarup; Rajajee, Venkatakrishna

    2014-09-01

    Current guidelines recommend against the use of phenytoin following aneurysmal subarachnoid hemorrhage (aSAH) but consider other anticonvulsants, such as levetiracetam, acceptable. Our objective was to evaluate the risk of poor functional outcomes, delayed cerebral ischemia (DCI) and delayed seizures in aSAH patients treated with levetiracetam versus phenytoin. Medical records of patients with aSAH admitted between 2005-2012 receiving anticonvulsant prophylaxis with phenytoin or levetiracetam for >72 hours were reviewed. The primary outcome measure was poor functional outcome, defined as modified Rankin Scale (mRS) score >3 at first recorded follow-up. Secondary outcomes measures included DCI and the incidence of delayed seizures. The association between the use of levetiracetam and phenytoin and the outcomes of interest was studied using logistic regression. Medical records of 564 aSAH patients were reviewed and 259 included in the analysis after application of inclusion/exclusion criteria. Phenytoin was used exclusively in 43 (17%), levetiracetam exclusively in 132 (51%) while 84 (32%) patients were switched from phenytoin to levetiracetam. Six (2%) patients had delayed seizures, 94 (36%) developed DCI and 63 (24%) had mRS score >3 at follow-up. On multivariate analysis, only modified Fisher grade and seizure before anticonvulsant administration were associated with DCI while age, Hunt-Hess grade and presence of intraparenchymal hematoma were associated with mRS score >3. Choice of anticonvulsant was not associated with any of the outcomes of interest. There was no difference in the rate of delayed seizures, DCI or poor functional outcome in patients receiving phenytoin versus levetiracetam after aSAH. The high rate of crossover from phenytoin suggests that levetiracetam may be better tolerated. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. NEGATIVE-ION MASS SPECTROMETRY OF SULFONYLUREA HERBICIDES

    EPA Science Inventory

    Sulfonylurea herbicides have been studied using neg-ion desorption chem.-ionization (DCI) mass spectrometry (MS) and DCI-MS/MS techniques. Both {M-H]- and M.- ions were obsd. in the DCI mass spectra. The collisonally activated dissocn. (CAD) spectra were characteristic of the str...

  4. Early whole-brain CT perfusion for detection of patients at risk for delayed cerebral ischemia after subarachnoid hemorrhage.

    PubMed

    Malinova, Vesna; Dolatowski, Karoline; Schramm, Peter; Moerer, Onnen; Rohde, Veit; Mielke, Dorothee

    2016-07-01

    OBJECT This prospective study investigated the role of whole-brain CT perfusion (CTP) studies in the identification of patients at risk for delayed ischemic neurological deficits (DIND) and of tissue at risk for delayed cerebral infarction (DCI). METHODS Forty-three patients with aneurysmal subarachnoid hemorrhage (aSAH) were included in this study. A CTP study was routinely performed in the early phase (Day 3). The CTP study was repeated in cases of transcranial Doppler sonography (TCD)-measured blood flow velocity (BFV) increase of > 50 cm/sec within 24 hours and/or on Day 7 in patients who were intubated/sedated. RESULTS Early CTP studies revealed perfusion deficits in 14 patients, of whom 10 patients (72%) developed DIND, and 6 of these 10 patients (60%) had DCI. Three of the 14 patients (21%) with early perfusion deficits developed DCI without having had DIND, and the remaining patient (7%) had neither DIND nor DCI. There was a statistically significant correlation between early perfusion deficits and occurrence of DIND and DCI (p < 0.0001). A repeated CTP was performed in 8 patients with a TCD-measured BFV increase > 50 cm/sec within 24 hours, revealing a perfusion deficit in 3 of them (38%). Two of the 3 patients (67%) developed DCI without preceding DIND and 1 patient (33%) had DIND without DCI. In 4 of the 7 patients (57%) who were sedated and/or comatose, additional CTP studies on Day 7 showed perfusion deficits. All 4 patients developed DCI. CONCLUSIONS Whole-brain CTP on Day 3 after aSAH allows early and reliable identification of patients at risk for DIND and tissue at risk for DCI. Additional CTP investigations, guided by TCD-measured BFV increase or persisting coma, do not contribute to information gain.

  5. Continuous electroencephalography predicts delayed cerebral ischemia after subarachnoid hemorrhage: A prospective study of diagnostic accuracy.

    PubMed

    Rosenthal, Eric S; Biswal, Siddharth; Zafar, Sahar F; O'Connor, Kathryn L; Bechek, Sophia; Shenoy, Apeksha V; Boyle, Emily J; Shafi, Mouhsin M; Gilmore, Emily J; Foreman, Brandon P; Gaspard, Nicolas; Leslie-Mazwi, Thabele M; Rosand, Jonathan; Hoch, Daniel B; Ayata, Cenk; Cash, Sydney S; Cole, Andrew J; Patel, Aman B; Westover, M Brandon

    2018-04-16

    Delayed cerebral ischemia (DCI) is a common, disabling complication of subarachnoid hemorrhage (SAH). Preventing DCI is a key focus of neurocritical care, but interventions carry risk and cannot be applied indiscriminately. Although retrospective studies have identified continuous electroencephalographic (cEEG) measures associated with DCI, no study has characterized the accuracy of cEEG with sufficient rigor to justify using it to triage patients to interventions or clinical trials. We therefore prospectively assessed the accuracy of cEEG for predicting DCI, following the Standards for Reporting Diagnostic Accuracy Studies. We prospectively performed cEEG in nontraumatic, high-grade SAH patients at a single institution. The index test consisted of clinical neurophysiologists prospectively reporting prespecified EEG alarms: (1) decreasing relative alpha variability, (2) decreasing alpha-delta ratio, (3) worsening focal slowing, or (4) late appearing epileptiform abnormalities. The diagnostic reference standard was DCI determined by blinded, adjudicated review. Primary outcome measures were sensitivity and specificity of cEEG for subsequent DCI, determined by multistate survival analysis, adjusted for baseline risk. One hundred three of 227 consecutive patients were eligible and underwent cEEG monitoring (7.7-day mean duration). EEG alarms occurred in 96.2% of patients with and 19.6% without subsequent DCI (1.9-day median latency, interquartile range = 0.9-4.1). Among alarm subtypes, late onset epileptiform abnormalities had the highest predictive value. Prespecified EEG findings predicted DCI among patients with low (91% sensitivity, 83% specificity) and high (95% sensitivity, 77% specificity) baseline risk. cEEG accurately predicts DCI following SAH and may help target therapies to patients at highest risk of secondary brain injury. Ann Neurol 2018. © 2018 American Neurological Association.

  6. N,N'-DICYCLOHEXYL-N"-ISOTRIDECYLGUANIDINE AS SUPPRESSOR FOR THE NEXT GENERATION CAUSTIC SIDE SOLVENT EXTRACTION (NG-CSSX) PROCESS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, Nathan C; Roach, Benjamin D; Williams, Neil J

    2012-01-01

    ABSTRACT The purity, concentration, and source of the N,N'-dicyclohexyl-N"-isotridecylguanidine (DCiTG) suppressor (guanidine) used in the NG-CSSX process were found to influence solvent performance. As the starting isotridecanol used in the preparation of DCiTG is comprised of a mixture of branched-chain aliphatic alcohols, varying in composition with manufacturer, the resulting DCiTG itself is a mixture. Thus, it is necessary to address how the solvent performance will be affected by the different preparations of the DCiTG solvent component. In this study, four preparations of DCiTG from three sources were analyzed and evaluated for purity and performance, both in the absence and presencemore » of an anionic surfactant impurity.« less

  7. The menstrual cycle regularization following D-chiro-inositol treatment in PCOS women: a retrospective study.

    PubMed

    La Marca, Antonio; Grisendi, Valentina; Dondi, Giulia; Sighinolfi, Giovanna; Cianci, Antonio

    2015-01-01

    Polycystic ovary syndrome is characterized by irregular cycles, hyperandrogenism, polycystic ovary at ultrasound and insulin resistance. The effectiveness of D-chiro-inositol (DCI) treatment in improving insulin resistance in PCOS patients has been confirmed in several reports. The objective of this study was to retrospectively analyze the effect of DCI on menstrual cycle regularity in PCOS women. This was a retrospective study of patients with irregular cycles who were treated with DCI. Of all PCOS women admitted to our centre, 47 were treated with DCI and had complete medical charts. The percentage of women reporting regular menstrual cycles significantly increased with increasing duration of DCI treatment (24% and 51.6% at a mean of 6 and 15 months of treatment, respectively). Serum AMH levels and indexes of insulin resistance significantly decreased during the treatment. Low AMH levels, high HOMA index, and the presence of oligomenorrhea at the first visit were the independent predictors of obtaining regular menstrual cycle with DCI. In conclusion, the use of DCI is associated to clinical benefits for many women affected by PCOS including the improvement in insulin resistance and menstrual cycle regularity. Responders to the treatment may be identified on the basis of menstrual irregularity and hormonal or metabolic markers.

  8. Modulation of gonadotrophin induced steroidogenic enzymes in granulosa cells by d-chiroinositol.

    PubMed

    Sacchi, Sandro; Marinaro, Federica; Tondelli, Debora; Lui, Jessica; Xella, Susanna; Marsella, Tiziana; Tagliasacchi, Daniela; Argento, Cindy; Tirelli, Alessandra; Giulini, Simone; La Marca, Antonio

    2016-08-31

    d-chiroinositol (DCI) is a inositolphosphoglycan (IPG) involved in several cellular functions that control the glucose metabolism. DCI functions as second messenger in the insulin signaling pathway and it is considered an insulin sensitizer since deficiency in tissue availability of DCI were shown to cause insulin resistance (IR). Polycystic ovary syndrome (PCOS) is a pathological condition that is often accompanied with insulin resistance. DCI can positively affects several aspect of PCOS etiology decreasing the total and free testosterone, lowering blood pressure, improving the glucose metabolism and increasing the ovulation frequency. The purpose of this study was to evaluate the effects of DCI and insulin combined with gonadotrophins namely follicle-stimulating hormone (FSH) and luteinizing hormone (LH) on key steroidogenic enzymes genes regulation, cytochrome P450 family 19 subfamily A member 1 (CYP19A1) and cytochrome P450 side-chain cleavage (P450scc) in primary cultures of human granulosa cells (hGCs). We also investigated whether DCI, being an insulin-sensitizer would be able to counteract the expected stimulator activity of insulin on human granulosa cells (hGCs). The study was conducted on primary cultures of hGCs. Gene expression was evaluated by RT-qPCR method. Statistical analysis was performed applying student t-test, as appropriate (P < 0.05) set for statistical significance. DCI is able to reduce the gene expression of CYP19A1, P450scc and insulin-like growth factor 1 receptor (IGF-1R) in dose-response manner. The presence of DCI impaired the increased expression of steroidogenic enzyme genes generated by the insulin treatment in gonadotrophin-stimulated hGCs. Insulin acts as co-gonadotrophin increasing the expression of steroidogenic enzymes genes in gonadotrophin-stimulated granulosa cells. DCI is an insulin-sensitizer that counteracts this action by reducing the expression of the genes CYP19A1, P450scc and IGF-1R. The ability of DCI to modulate in vitro ovarian activity of insulin could in part explain its beneficial effect when used as treatment for conditions associated to insulin resistance.

  9. Pedobacter panacis sp. nov., isolated from Panax ginseng soil.

    PubMed

    Singh, Priyanka; Singh, Hina; Kim, Yeon-Ju; Yang, Deok-Chun

    2017-02-01

    A novel strain, DCY108 T was isolated from soil of a Panax ginseng field, Yeoncheon province (38°04'N 126°57'E), Republic of Korea. Strain DCY108 T is Gram-negative, non-motile, non-flagellate, rod-shaped, and aerobic. The bacterium grows optimally at 25-30 °C, pH 6.5-7.0 and 1 % NaCl. Phylogenetically, strain DCY108 T is closely related to Pedobacter jejuensis JCM 18824 T , Pedobacter aquatilis JCM 13454 T , Pedobacter kyungheensis LMG 26577 T and the type strain of the genus Pedobacter heparinus DSM 2366 T . The DNA-DNA relatedness values between strain DCY108 T and its close phylogenetic neighbors were below 30.0 %. The DNA G+C content of strain DCY108 T was determined to be 45.1 mol%. The predominant quinone was menaquinone 7 (MK-7). The major polar lipids were identified as phosphatidylethanolamine and three unidentified aminolipids AL1, AL13 and AL17. Iso-C 15:00 , iso-C 17:0 3OH and summed feature 3 (C 16:1 ω7c/C 16:1 ω6c) were identified as the major fatty acids present in strain DCY108 T . The results of physiological and biochemical tests allowed strain DCY108 T to be differentiated phenotypically from other recognized species belonging to the genus Pedobacter. Therefore, it is suggested that the newly isolated organism represents a novel species, for which the name Pedobacter panacis sp. nov is proposed with the type strain designated as DCY108 T (=CCTCCAB 2015196 T  = KCTC 42748 T ).

  10. Measuring the Impact of Delayed Cerebral Ischemia on Neuropsychological Outcome After Aneurysmal Subarachnoid Hemorrhage-Protocol of a Swiss Nationwide Observational Study (MoCA-DCI Study).

    PubMed

    Stienen, Martin N; Fung, Christian; Bijlenga, Philippe; Zumofen, Daniel W; Maduri, Rodolfo; Robert, Thomas; Seule, Martin A; Marbacher, Serge; Geisseler, Olivia; Brugger, Peter; Gutbrod, Klemens; Chicherio, Christian; Monsch, Andreas U; Beaud, Valérie; Rossi, Stefania; Früh, Severin; Schmid, Nicole; Smoll, Nicolas R; Keller, Emanuela; Regli, Luca

    2018-05-11

    The exact relationship between delayed cerebral ischemia (DCI) following aneurysmal subarachnoid hemorrhage (aSAH) and neuropsychological impairment remains unknown, as previous studies lacked a baseline examination after aneurysm occlusion but before the DCI-period. Neuropsychological evaluation of acutely ill patients is often applied in a busy intensive care unit (ICU), where distraction represents a bias to the obtained results. To evaluate the relationship between DCI and neuropsychological outcome after aSAH by comparing the Montreal Cognitive Assessment (MoCA) results in aSAH patients with and without DCI at 3 mo with a baseline examination before the DCI-period (part 1). To determine the reliability of the MoCA, when applied in an ICU setting (part 2). Prospective, multicenter, and observational study performed at all Swiss neurovascular centers. For part 1, n = 240 consecutive aSAH patients and for part 2, n = 50 patients with acute brain injury are recruited. Part 1: Effect size of the relationship between DCI and neuropsychological outcome (MoCA). Part 2: Reliability measures for the MoCA. The institutional review boards approved this study on July 4, 2017 under case number BASEC 2017-00103. After completion, the results will be offered to an international scientific journal for peer-reviewed publication. This study determines the exact impact of DCI on the neuropsychological outcome after aSAH, unbiased by confounding factors such as early brain injury or patient-specific characteristics. The study provides unique insights in the neuropsychological state of patients in the early period after aSAH.

  11. Decompression illness in goats following simulated submarine escape: 1993-2006.

    PubMed

    Seddon, F M; Thacker, J C; Fisher, A S; Jurd, K M; White, M G; Loveman, G A M

    2014-01-01

    The United Kingdom Ministry of Defence commissioned work to define the relationship between the internal pressure of a distressed submarine (DISSUB), the depth from which escape is made and the risk of decompression illness (DCI). The program of work used an animal model (goat) to define these risks and this paper reports the incidence and type of DCI observed. A total of 748 pressure exposures comprising saturation only, escape only or saturation followed by escape were conducted in the submarine escape simulator between 1993 and 2006. The DCI following saturation exposures was predominantly limb pain, whereas following escape exposures the DCI predominantly involved the central nervous system and was fast in onset. There was no strong relationship between the risk of DCI and the range of escape depths investigated. The risk of DCI incurred from escape following saturation was greater than that obtained by combining the risks for the independent saturation only, and escape only, exposures. The output from this program of work has led to improved advice on the safety of submarine escape.

  12. Paenibacillus yonginensis sp. nov., a potential plant growth promoting bacterium isolated from humus soil of Yongin forest.

    PubMed

    Sukweenadhi, Johan; Kim, Yeon-Ju; Lee, Kwang Je; Koh, Sung-Cheol; Hoang, Van-An; Nguyen, Ngoc-Lan; Yang, Deok-Chun

    2014-11-01

    Strain DCY84(T), a Gram-stain positive, rod-shaped, aerobic, spore-forming bacterium, motile by means of peritrichous flagella, was isolated from humus soil from Yongin forest in Gyeonggi province, South Korea. Strain DCY84(T) shared the highest sequence similarity with Paenibacillus barengoltzii KACC 15270(T) (96.86 %), followed by Paenibacillus timonensis KACC 11491(T) (96.49 %) and Paenibacillus phoenicis NBRC 106274(T) (95.77 %). Strain DCY84(T) was found to able to grow best in TSA at temperature 30 °C, at pH 8 and at 0.5 % NaCl. MK-7 menaquinone was identified as the isoprenoid quinone. The major polar lipids were identified as phosphatidylethanolamine, an unidentified aminophospholipid, two unidentified aminolipids and an unidentified polar lipid. The peptidoglycan was found to contain the amino acids meso-diaminopimelic acid, alanine and D-glutamic acid. The major fatty acids of strain DCY84(T) were identified as branched chain anteiso-C15:0, saturated C16:0 and branched chain anteiso-C17:0. The cell wall sugars of strain DCY84(T) were found to comprise of ribose, galactose and xylose. The major polyamine was identified as spermidine. The DNA G+C content was determined to be 62.6 mol%. After 6 days of incubation, strain DCY84(T) produced 52.96 ± 1.85 and 72.83 ± 2.86 µg/ml L-indole-3-acetic acid, using media without L-tryptophan and supplemented with L-tryptophan, respectively. Strain DCY84(T) was also found to be able to solubilize phosphate and produce siderophores. On the basis of the phenotypic characteristics, genotypic analysis and chemotaxonomic characteristics, strain DCY84(T) is considered to represent a novel species of the genus Paenibacillus, for which the name Paenibacillus yonginensis sp. nov. is proposed. The type strain is DCY84(T) (=KCTC 33428(T) = JCM 19885(T)).

  13. Retrospective review of previous minor leak before major subarachnoid hemorrhage diagnosed by MRI as a predictor of occurrence of symptomatic delayed cerebral ischemia.

    PubMed

    Oda, Shinri; Shimoda, Masami; Hirayama, Akihiro; Imai, Masaaki; Komatsu, Fuminari; Shigematsu, Hideaki; Nishiyama, Jun; Hotta, Kazuko; Matsumae, Mitsunori

    2018-02-01

    OBJECTIVE This study attempted to determine whether a previous minor leak correlated with the occurrence of symptomatic delayed cerebral ischemia (sDCI). METHODS The authors retrospectively evaluated sDCI-related clinical features and findings from MRI, including T1-weighted imaging (T1WI)-FLAIR mismatch at the time of admission, in 151 patients admitted with subarachnoid hemorrhage (SAH) within 48 hours of ictus. RESULTS The overall incidence of sDCI was 23% (35 of 151 patients). In all subjects, multivariate analysis revealed that World Federation of Neurosurgical Societies Grades II-V, age 70 years or older, presence of rebleeding after admission, a previous minor leak before the major SAH attack as diagnosed by T1WI-FLAIR mismatch, acute infarction on diffusion-weighted imaging, and CT SAH score were significantly associated with occurrence of sDCI. In patients with no previous minor leak before major SAH as diagnosed by T1WI-FLAIR mismatch, the incidence of sDCI was only 7% (7 of 97 patients). CONCLUSIONS A previous minor leak before major SAH as diagnosed by T1WI-FLAIR mismatch represents an important sDCI-related factor. When the analysis was restricted to patients with true acute SAH without a previous minor leak diagnosed by T1WI-FLAIR mismatch, the incidence of sDCI was extremely low.

  14. Treatment of juvenile recurrent parotitis of childhood: an analysis of effectiveness.

    PubMed

    Roby, Brianne Barnett; Mattingly, Jameson; Jensen, Emily L; Gao, Dexiang; Chan, Kenny H

    2015-02-01

    Juvenile recurrent parotitis (JRP) is characterized by recurrent painful swelling of the parotid gland that occurs in the pediatric population. Sialendoscopy with and without ductal corticosteroid infusion (DCI) has been found to be effective in the treatment of JRP and autoimmune parotitis. To determine the utility of instrumentation vs pharmacotherapy alone for juvenile recurrent parotitis. A retrospective medical record review of pediatric patients undergoing DCI without sialendoscopy at a tertiary pediatric hospital was conducted. The medical records were reviewed to determine the frequency of parotitis events before and after treatment. A multiquestion telephone survey of patients and their parents who underwent the procedure was then conducted to determine patient satisfaction. Ductal corticosteroid infusion with hydrocortisone through catheter inserted in the parotid duct. Frequency of symptoms before and after treatment and parental satisfaction with the treatment. Twelve patients with a mean age of 6.7 years were identified. The mean duration and frequency of symptoms before the procedure were 22 months and every 2 months, respectively. Five patients had a recurrence, on average 4 months after the procedure. Four patients underwent repeated surgical procedures. All had a longer duration between episodes compared with before DCI. Eight parents participated in the survey on satisfaction with the procedure, and 75% reported improvement in their child's life postprocedure. Current literature shows sialendoscopy with corticosteroid application is successful in treating JRP, but it is unclear whether corticosteroid application alone would treat JRP equally. This study shows that DCI alone has similar results as sialendoscopy with corticosteroid application, indicating that it is the corticosteroid application and not the sialendoscopy causing improvement in symptoms. Because JRP must be differentiated from sialolithiasis, we recommend ultrasonography of the involved parotid(s) prior to using DCI alone to ensure no stone is present. Sialendoscopy should be reserved to rule out other parotid ductal pathologic conditions.

  15. High Resolution Manometry Correlates of Ineffective Esophageal Motility

    PubMed Central

    Xiao, Yinglian; Kahrilas, Peter J.; Kwasny, Mary J.; Roman, Sabine; Lin, Zhiyue; Nicodème, Frédéric; Lu, Chang; Pandolfino, John E.

    2013-01-01

    Background There are currently no criteria for ineffective esophageal motility (IEM) and ineffective swallow (IES) in High Resolution Manometry (HRM) and Esophageal Pressure Topography (EPT). Our aims were to utilize HRM metrics to define IEM within the Chicago Classification and to determine the distal contractile integral (DCI) threshold for IES. Methods The EPT of 150 patients with either dysphagia or reflux symptoms were reviewed for the breaks >2 cm in the proximal, middle and distal esophagus in the 20 mmHg isobaric contour (IBC). Peristaltic function in EPT was defined by the Chicago Classification, the corresponding conventional line tracing (CLT) were reviewed separately for IEM and IES. Generalized linear mixed models were used to find thresholds for DCI corresponding to traditionally determined IES and failed swallows. An external validation sample was used to confirm these thresholds. Results In terms of swallow subtypes, IES in CLT were a mixture of normal, weak and failed peristalsis in EPT. A DCI of 450mmHg-s-cm was determined to be optimal in predicting IES. In the validation sample, the threshold of 450 mmHg-s-cm showed strong agreement with CLT determination of IES (positive percent agreement 83%, negative percent agreement 90%) Thirty-three among 42 IEM patients in CLT had large peristaltic breaks, small peristaltic breaks or ‘frequent failed peristalsis’ in EPT; 87.2% (34/39) of patients classified as normal in CLT had proximal IBC-breaks in EPT. the patient level diagnostic agreement between CLT and EPT was good (78.6% positive percent agreement, 63.9% negative percent agreement), with negative agreement increasing to 92.0% if proximal breaks were excluded. Conclusions The manometric correlate of IEM in EPT is a mixture of failed swallows and IBC break in the middle/ distal troughs. A DCI value<450 mmHg-s-cm can be utilized to predict IES previously defined in CLT. IEM can be defined by >5 swallows with weak /failed peristalsis or with a DCI <450 mmHg-s-cm. PMID:22929758

  16. Comparison of the size of persistent foramen ovale and atrial septal defects in divers with shunt-related decompression illness and in the general population.

    PubMed

    Wilmshurst, Peter T; Morrison, W Lindsay; Walsh, Kevin P

    2015-06-01

    Decompression illness (DCI) is associated with a right-to-left shunt, such as persistent foramen ovale (PFO), atrial septal defect (ASD) and pulmonary arteriovenous malformations. About one-quarter of the population have a PFO, but considerably less than one-quarter of divers suffer DCI. Our aim was to determine whether shunt-related DCI occurs mainly or entirely in divers with the largest diameter atrial defects. Case control comparison of diameters of atrial defects (PFO and ASD) in 200 consecutive divers who had transcatheter closure of an atrial defect following shunt-related DCI and in an historic group of 263 individuals in whom PFO diameter was measured at post-mortem examination. In the divers who had experienced DCI, the median atrial defect diameter was 10 mm and the mean (standard deviation) was 9.9 (3.6) mm. Among those in the general population who had a PFO, the median diameter was 5 mm and mean was 4.9 (2.6) mm. The difference between the two groups was highly significant (P < 0.0001). Of divers with shunt-related DCI, 101 (50.5%) had an atrial defect 10 mm diameter or larger, but only 1.3% of the general population studied had a PFO that was 10 mm diameter of larger. The risk of a diver suffering DCI is related to the size of the atrial defect rather than just the presence of a defect.

  17. Definition of delayed cerebral ischemia after aneurysmal subarachnoid hemorrhage as an outcome event in clinical trials and observational studies: proposal of a multidisciplinary research group.

    PubMed

    Vergouwen, Mervyn D I; Vermeulen, Marinus; van Gijn, Jan; Rinkel, Gabriel J E; Wijdicks, Eelco F; Muizelaar, J Paul; Mendelow, A David; Juvela, Seppo; Yonas, Howard; Terbrugge, Karel G; Macdonald, R Loch; Diringer, Michael N; Broderick, Joseph P; Dreier, Jens P; Roos, Yvo B W E M

    2010-10-01

    In clinical trials and observational studies there is considerable inconsistency in the use of definitions to describe delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage. A major cause for this inconsistency is the combining of radiographic evidence of vasospasm with clinical features of cerebral ischemia, although multiple factors may contribute to DCI. The second issue is the variability and overlap of terms used to describe each phenomenon. This makes comparisons among studies difficult. An international ad hoc panel of experts involved in subarachnoid hemorrhage research developed and proposed a definition of DCI to be used as an outcome measure in clinical trials and observational studies. We used a consensus-building approach. It is proposed that in observational studies and clinical trials aiming to investigate strategies to prevent DCI, the 2 main outcome measures should be: (1) cerebral infarction identified on CT or MRI or proven at autopsy, after exclusion of procedure-related infarctions; and (2) functional outcome. Secondary outcome measure should be clinical deterioration caused by DCI, after exclusion of other potential causes of clinical deterioration. Vasospasm on angiography or transcranial Doppler can also be used as an outcome measure to investigate proof of concept but should be interpreted in conjunction with DCI or functional outcome. The proposed measures reflect the most relevant morphological and clinical features of DCI without regard to pathogenesis to be used as an outcome measure in clinical trials and observational studies.

  18. Esophagogastric junction and esophageal body contraction metrics on high-resolution manometry predict esophageal acid burden.

    PubMed

    Rengarajan, A; Bolkhir, A; Gor, P; Wang, D; Munigala, S; Gyawali, C P

    2018-05-01

    Distal contractile integral (DCI) and esophagogastric junction contractile integral (EGJ-CI) are high-resolution manometry (HRM) software metrics assessing esophageal motor function in gastroesophageal reflux disease (GERD). Patients undergoing HRM and ambulatory pH monitoring off antisecretory therapy prospectively completed symptom questionnaires assessing symptom burden and a global symptom score (GSS) at baseline and after GERD therapy. DCI<450 mm Hg/cm/s in ≥5 swallows diagnosed ineffective esophageal motility (IEM); proportions of failed (DCI<100 mm Hg/cm/s) and weak (DCI 100-450 mm Hg/cm/s) sequences were separately assessed. EGJ-CI assessed vigor of the EGJ barrier. Univariate and multivariate analyses addressed performance of esophageal body and EGJ metrics in predicting abnormal esophageal reflux burden, and symptom outcome from antireflux therapy. Of 188 patients (55.2 ± 0.9 year, 64% F), 42.6% had low EGJ-CI, and 25.0% had IEM. While low EGJ-CI was associated with abnormal reflux burden (P = 0.003), IEM alone was not (P = 0.2). Increasing proportions of failed swallows predicted abnormal AET better than the current IEM definition. Combined low EGJ-CI and IEM segregated abnormal total and supine acid burden compared to patients with normal EGJ-CI and no IEM (P ≤ 0.007 for each comparison). Medical therapy and surgical antireflux therapy were similarly effective in improving symptom burden; surgery resulted in better outcomes with low EGJ-CI (P ≤ 0.04), especially with intact esophageal body motor function (P = 0.02). While abnormal EGJ and esophageal body metrics are collectively associated with elevated esophageal reflux burden, increasing proportions of failed swallows are better predictors of reflux burden and outcome compared to the current IEM definition. © 2017 John Wiley & Sons Ltd.

  19. Correlation between 99Tcm-HMPAO-SPECT brain image and a history of decompression illness or extent of diving experience in commercial divers.

    PubMed Central

    Shields, T G; Duff, P M; Evans, S A; Gemmell, H G; Sharp, P F; Smith, F W; Staff, R T; Wilcock, S E

    1997-01-01

    OBJECTIVES: To explore the use of 99technetiumm-hexamethyl propylene amine oxime single photon computed tomography (HMPAO-SPECT) of the brain as a means of detecting nervous tissue damage in divers and to determine if there is any correlation between brain image and a diver's history of diving or decompression illness (DCI). METHODS: 28 commercial divers with a history of DCI, 26 divers with no history of DCI, and 19 non-diving controls were examined with brain HMPAO-SPECT. Results were classified by observer assessment as normal (I) or as a pattern variants (II-V). The brain images of a subgroup of these divers (n = 44) and the controls (n = 17) were further analysed with a first order texture analysis technique based on a grey level histogram. RESULTS: 15 of 54 commercial divers (28%) were visually assessed as having HMPAO-SPECT images outside normal limits compared with 15.8% in appropriately identified non-diver control subjects. 18% of divers with a history of DCI were classified as having a pattern different from the normal image compared with 38% with no history of DCI. No association was established between the presence of a pattern variant from the normal image and history of DCI, diving, or other previous possible neurological insult. On texture analysis of the brain images, divers had a significantly lower mean grey level (MGL) than non-divers. Divers with a history of DCI (n = 22) had a significantly lower MGL when compared with divers with no history of DCI (n = 22). Divers with > 14 years professional diving or > 100 decompression days a year had a significantly lower MGL value. CONCLUSIONS: Observer assessment of HMPAO-SPECT brain images can lead to disparity in results. Texture analysis of the brain images supplies both an objective and consistent method of measurement. A significant correlation was found between a low measure of MGL and a history of DCI. There was also an indication that diving itself had an effect on texture measurement, implying that it had caused subclinical nervous tissue damage. PMID:9166130

  20. Asymmetric and Symmetric Dimethylarginines are Markers of Delayed Cerebral Ischemia and Neurological Outcome in Patients with Subarachnoid Hemorrhage.

    PubMed

    Appel, Daniel; Seeberger, Miriam; Schwedhelm, Edzard; Czorlich, Patrick; Goetz, Alwin E; Böger, Rainer H; Hannemann, Juliane

    2018-03-20

    Delayed cerebral ischemia (DCI) is the major cause of lethality and neuronal damage in patients who survived the primary subarachnoid hemorrhage (SAH). Asymmetric and symmetric dimethylarginines (ADMA and SDMA) inhibit nitric oxide production from L-arginine via distinct mechanisms. Elevated ADMA levels are associated with vasospasm after SAH. We aimed to study the time course of ADMA and SDMA in plasma and ventricular cerebrospinal fluid (CSF) and their associations with DCI and outcome. We measured ADMA and SDMA in 34 SAH patients with an external ventricular drain at admission and on days 3, 6, 8, 12, and 15 and followed them up for clinical status and neurological outcome until 30 days post-discharge. DCI was defined as the appearance of new infarctions on cerebral computed tomography or magnetic resonance imaging. ADMA and SDMA plasma concentrations did not differ significantly at baseline between patients who suffered DCI (N = 14; 41%) and not; however, plasma ADMA reached a peak on days 8 and 15 after hemorrhage in patients with DCI (0.81-0.91 µmol/l). Baseline plasma L-arginine/ADMA ratio was significantly lower in patients with DCI (57.1 [34.3; 70.8] vs. 68.7 [55.7; 96.2]; p < 0.05). ADMA and SDMA concentrations in CSF were significantly higher in patients with DCI than without. In multivariable-adjusted linear regression models, CSF ADMA was negatively associated with the incidence of DCI (OR 0.03 [0.02-0.70]; p = 0.04), whereas CSF SDMA on the day of hemorrhage predicted poor neurological outcome until 30 days after discharge (OR 22.4 [1.21-416.02]; p = 0.04). Our study shows that ADMA and the L-arginine/ADMA ratio are associated with the incidence of DCI after SAH. By contrast, SDMA was associated with initial neuronal damage and poor neurological outcome after SAH. These data support the hypothesis that ADMA and L-arginine affect the pathophysiology of cerebral ischemia after SAH, while SDMA is a biomarker of neurological outcome after SAH.

  1. In vitro analysis of platelet function in acute aneurysmal subarachnoid haemorrhage.

    PubMed

    von der Brelie, Christian; Subai, Alexander; Limperger, Verena; Rohde, Veit; Dempfle, Astrid; Boström, Azize

    2018-04-01

    Platelet function might play an essential role in the pathogenesis of delayed cerebral ischemia (DCI) after aneurysmal subarachnoid haemorrhage (SAH). Thus, impaired platelet function and disturbed primary haemostasis induced by intake of acetylsalicylic acid (ASA) might influence the rate of DCI. Primary haemostasis and platelet function can be measured with in vitro diagnosis (platelet function analyser test, PFA 100). The aim of this study is to evaluate the rate of DCI, haemorrhagic complications and the neurological outcome. Two groups were compared (patients with regular platelet function versus patients with impaired platelet function). This is a retrospective observational study. An initial cohort of 787 patients with SAH has been treated from January 2005 to September 2012. Seventy-nine patients (10%) with aneurysmal SAH, a history of ASA medication and PFA testing within the first 24 h after aneurysm rupture have been included. The overall rate of DCI in the present study was 43%. In vitro platelet function testing showed pathological primary haemostasis in 69.6%. The DCI rate was higher in patients with regular tested primary haemostasis (p = 0.02, OR = 3.16, 95%CI = [1.19; 8.83]). However, outcome assessment by mGOS did not show a significant difference between the groups. Patients with impaired primary haemostasis did not display a higher rate of haemorrhagic complications. Impairment of primary haemostasis resulting from an impairment of platelet function at an early stage after SAH might lead to a lower rate of DCI. In vitro testing of platelet function might be useful to predict the occurrence of DCI in the course.

  2. Safety of Performing a Delayed Anastomosis During Damage Control Laparotomy in Patients with Destructive Colon Injuries

    PubMed Central

    Ordoñez, Carlos A; Pino, Luis F; Badiel, Marisol; Sánchez, Alvaro I; Loaiza, Jhon; Ballestas, Leonardo; Puyana, Juan Carlos

    2011-01-01

    Background Recent studies report the safety and feasibility of performing delayed anastomosis (DA) in patients undergoing damage control laparotomy (DCL) for destructive colon injuries (DCI). Despite accumulating experience in both civilian and military trauma, questions regarding how to best identify high risk patients and minimize the number of anastomosis-associated complications remain. Our current practice is to perform a definitive closure of the colon during DCL, unless there is persistent acidosis, bowel wall edema, or evidence of intra-abdominal abscess. In this study, we evaluated the safety of this approach by comparing outcomes of patients with DCI who underwent definitive closure of the colon during DCL versus patients managed with colostomy with or without DCL. Methods We performed a retrospective chart review of patients with penetrating DCI during 2003–2009. Severity of injury, surgical management, and clinical outcome were assessed. Results Sixty patients with severe gunshot wounds (GSW) and 3 patients with stab wounds were included in the analysis. DCL was required in 30 patients, all with GSW. Three patients died within the first 48 hours, 3 underwent colostomy, and 24 were managed with DA. Thirty-three patients were managed with standard laparotomy: 26 patients with primary anastomosis, and 7 with colostomy. Overall mortality rate was 9.5%. Three late deaths occurred in the DCL group, and only one death was associated with an anastomotic leak. Conclusions Performing a DA in DCI during DCL is a reliable and feasible approach as long as severe acidosis, bowel wall edema, and/or persistent intra-abdominal infections are not present. PMID:22182861

  3. Flavobacterium panacis sp. nov., isolated from rhizosphere of Panax ginseng.

    PubMed

    Kim, Dong Hyun; Singh, Priyanka; Farh, Mohamed El-Agamy; Kim, Yeon-Ju; Nguyen, Ngoc-Lan; Lee, Hyun A; Yang, Deok-Chun

    2016-09-01

    A novel bacterial strain, designated DCY106(T), was isolated from soil collected from the rhizosphere of ginseng (Panax ginseng), in Gochang, Republic of Korea. Strain DCY106(T) is Gram-negative, yellow-pigmented, non-flagellate, motile, non-spore-forming, rod-shaped, and strictly aerobic. The strain grows optimally at 25-30 °C and pH 6.5-7.5. Phylogenetically, strain DCY106(T) is closely related to Flavobacterium arsenitoxidans KCTC 22507(T) (98.41 %), followed by Flavobacterium cutihirudini LMG 26922(T) (97.67 %), Flavobacterium nitrogenifigens LMG 28694(T) (97.59 %), Flexibacter auranticus LMG 3987(T) (97.38 %), Flavobacterium defluvi KCTC 12612(T) (97.21 %) and Flavobacterium chilense LMG 26360(T) (97.05 %). The 16S rRNA gene sequence similarities to all other Flavobacterium species were below 97 %. The DNA G+C content of strain DCY106(T) is 34.2 mol% and the DNA-DNA relatedness between strain DCY106(T) and F. cutihirudini LMG 26922(T), F. auranticus LMG 3987(T), F. defluvi KCTC 12612(T) and F. chilense LMG 26360(T) were below 40.0 %. The menaquinone of the type MK-6 was found to be the predominant respiratory quinone. The major polar lipids were identified as phosphatidylethanolamine, phosphatidylserine, two unidentified aminolipids (APL1, APL6) and one unidentified lipid L2. C15:0, iso-C15:0 and summed feature 3 (iso-C15:0 2OH/C16:1 ω7c) were identified as the major fatty acids present in DCY106(T). The results of physiological and biochemical tests allowed strain DCY106(T) to be differentiated phenotypically from other recognized species belonging to the genus Flavobacterium. Therefore, it is suggested that the newly isolated organism represents a novel species, for which the name Flavobacterium panacis sp. nov. is proposed with the type strain designated as DCY106(T) (= JCM 31468(T)= KCTC 42747(T)).

  4. Paenibacillus kyungheensis sp. nov., isolated from flowers of magnolia.

    PubMed

    Siddiqi, Muhammad Zubair; Siddiqi, Muhammad Hanif; Im, Wan Taek; Kim, Yeon-Ju; Yang, Deok-Chun

    2015-11-01

    A Gram-staining-positive, catalase-positive, oxidase-negative, facultatively anaerobic, rod-shaped bacterium designated strain DCY88T, was isolated from flowers of magnolia. Phylogenetic analysis based on 16S rRNA gene sequence comparison revealed that the strain formed a distinct lineage within the genus Paenibacillus that was closely related to Paenibacillus hordei RH-N24T (97.8 %). The other most closely related species were Paenibacillus illinoisensis NRRL NRS-1356T (94.3 %), Paenibacillus hunanensis DSM 22170T (94.2 %), Paenibacillus peoriae DSM 8320T (93.9 %), Paenibacillus kribbensis Am49T (93.8 %) and the type species of the genus, Paenibacillus polymyxa ATCC 842T (93.3 %). Cells of the strain were endospore-forming and motile by peritrichous flagella. Strain DCY88T formed pink-pigmented colonies on trypticase soy agar and R2A agar medium. Growth of strain DCY88T occurs at temperatures 5-37 °C, at pH 4-9 and 0.5-5.5 % NaCl (w/v). The menaquinone was MK-7.The cell wall peptidoglycan of strain DCY88T contained meso-diaminopimelic acid. The major fatty acids were anteiso-C15 : 0 (61.0 %) and C16 : 0 (11.0 %). The major polar lipids were diphosphatidylglycerol, phosphatidylglycerol, phosphatidylethanolamine and an unidentified polar lipid. The strain DCY88T contained spermidine as the major polyamine. The DNA G+C content was 51.6 mol%. The DNA-DNA hybridization relatedness between strain DCY88T and P. hordei RH-N24T was 48 ± 2 %. The phenotypic, phylogenetic and chemotaxonomic results indicate that the strain DCY88T represents a novel species of the genus Paenibacillus, for which the name Paenibacillus kyungheensis sp. nov. is proposed. The type strain is DCY88T ( = JCM 19886T = KCTC 33429T).

  5. Venous gas emboli and exhaled nitric oxide with simulated and actual extravehicular activity.

    PubMed

    Karlsson, Lars L; Blogg, S Lesley; Lindholm, Peter; Gennser, Mikael; Hemmingsson, Tryggve; Linnarsson, Dag

    2009-10-01

    The decompression experienced due to the change in pressure from a space vehicle (1013hPa) to that in a suit for extravehicular activity (EVA) (386hPa) was simulated using a hypobaric chamber. Previous ground-based research has indicated around a 50% occurrence of both venous gas emboli (VGE) and symptoms of decompression illness (DCI) after similar decompressions. In contrast, no DCI symptoms have been reported from past or current space activities. Twenty subjects were studied using Doppler ultrasound to detect any VGE during decompression to 386hPa, where they remained for up to 6h. Subjects were supine to simulate weightlessness. A large number of VGE were found in one subject at rest, who had a recent arm fracture; a small number of VGE were found in another subject during provocation with calf contractions. No changes in exhaled nitric oxide were found that can be related to either simulated EVA or actual EVA (studied in a parallel study on four cosmonauts). We conclude that weightlessness appears to be protective against DCI and that exhaled NO is not likely to be useful to monitor VGE.

  6. Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

    NASA Technical Reports Server (NTRS)

    Feiveson, Alan H.; Foster, Philip P.

    2001-01-01

    The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

  7. Genetic modification of Bacillus subtilis for production of D-chiro-inositol, an investigational drug candidate for treatment of type 2 diabetes and polycystic ovary syndrome.

    PubMed

    Yoshida, Ken-ichi; Yamaguchi, Masanori; Morinaga, Tetsuro; Ikeuchi, Maya; Kinehara, Masaki; Ashida, Hitoshi

    2006-02-01

    D-chiro-inositol (DCI) is a drug candidate for the treatment of type 2 diabetes and polycystic ovary syndrome, since it improves the efficiency with which the body uses insulin and also promotes ovulation. Here, we report genetic modification of Bacillus subtilis for production of DCI from myo-inositol (MI). The B. subtilis iolABCDEFGHIJ operon encodes enzymes for the multiple steps of the MI catabolic pathway. In the first and second steps, MI is converted to 2-keto-MI (2KMI) by IolG and then to 3D-(3,5/4)-trihydroxycyclohexane-1,2-dione by IolE. In this study, we identified iolI encoding inosose isomerase, which converts 2KMI to 1-keto-D-chiro-inositol (1KDCI), and found that IolG reduces 1KDCI to DCI. Inactivation of iolE in a mutant constitutively expressing the iol operon blocked the MI catabolic pathway to accumulate 2KMI, which was converted to DCI via the activity of IolI and IolG. The mutant was able to convert at least 6% of input MI in the culture medium to DCI.

  8. Discovery of Novel Inhibitors of Indoleamine 2,3-Dioxygenase 1 Through Structure-Based Virtual Screening

    PubMed Central

    Zhang, Guoqing; Xing, Jing; Wang, Yulan; Wang, Lihao; Ye, Yan; Lu, Dong; Zhao, Jihui; Luo, Xiaomin; Zheng, Mingyue; Yan, Shiying

    2018-01-01

    Indoleamine 2,3-dioxygenase 1 (IDO1) is an intracellular monomeric heme-containing enzyme that catalyzes the first and the rate limiting step in catabolism of tryptophan via the kynurenine (KYN) pathway, which plays a significant role in the proliferation and differentiation of T cells. IDO1 has been proven to be an attractive target for anticancer therapy and chronic viral infections. In the present study, a class of IDO1 inhibitors with novel scaffolds were identified by virtual screening and biochemical validation, in which the compound DC-I028 shows moderate IDO1 inhibitory activity with an IC50 of 21.61 μM on enzymatic level and 89.11 μM on HeLa cell. In the following hit expansion stage, DC-I02806, an analog of DC-I028, showed better inhibitory activity with IC50 about 18 μM on both enzymatic level and cellular level. The structure–activity relationship (SAR) of DC-I028 and its analogs was then discussed based on the molecular docking result. The novel IDO1 inhibitors of DC-I028 and its analogs may provide useful clues for IDO1 inhibitor development. PMID:29651242

  9. Paracoccus panacisoli sp. nov., isolated from a forest soil cultivated with Vietnamese ginseng.

    PubMed

    Nguyen, Ngoc-Lan; Kim, Yeon-Ju; Hoang, Van-An; Tran, Bao-Tram; Pham, Huong-Son; Yang, Deok-Chun

    2015-05-01

    A novel bacterial strain, designated DCY94(T), was isolated from forest soil cultivated with ginseng in Vietnam. The strain was Gram-reaction-negative, facultatively anaerobic, non-motile, rod-shaped and catalase- and oxidase-positive. 16S rRNA gene sequence analysis demonstrated that strain DCY94(T) was closely related to Paracoccus sphaerophysae Zy-3(T) (97.5% 16S rRNA gene sequence similarity) and Paracoccus caeni MJ17(T) (96.9%). The fatty acid profile of strain DCY94(T) contained a predominant amount of summed feature 8 (C18 : 1ω7c and/or C18 : 1ω6c; 88.4%) and moderate to small quantities of C8 : 0 3-OH (1.0%), C10 : 0 3-OH (2.8%) and C18 : 0 (5.2%). Phosphatidylethanolamine, phosphatidylglycerol, phosphatidylcholine and one unidentified glycolipid were major polar lipids; one unidentified aminolipid, one unidentified aminophospholipid, one unidentified phospholipid and four unidentified polar lipids were minor components. The polyamine pattern comprised the major compounds putrescine and spermidine and minor amounts of sym-homospermidine and spermine. The ubiquinone of the strain was Q-10 and the G+C content of its genomic DNA was 68.3 mol%. All these results support the placement of strain DCY94(T) within the genus Paracoccus . Levels of DNA-DNA relatedness between strain DCY94(T) and P. sphaerophysae HAMBI 3106(T) and P. caeni KCTC 22480(T) were 52 and 50%, respectively. The results of phylogenetic analysis, phenotypic tests, chemotaxonomic characterization and DNA-DNA relatedness studies distinguished strain DCY94(T) from the closest recognized species of the genus Paracoccus , suggesting that this strain represents a novel species, for which the name Paracoccus panacisoli sp. nov. is proposed. The type strain is DCY94(T) ( = KCTC 42086(T) =JCM 30337(T)). © 2015 IUMS.

  10. EFFECTS OF BACTERIAL ENDOTOXINS ON METABOLISM

    PubMed Central

    Berry, L. Joe; Smythe, Dorothy S.

    1961-01-01

    In vitro secretion of glycocorticoids by adrenal glands pooled from several control mice was compared with that of glands removed from animals following injections of either ACTH or endotoxin. Both substances prevent glycocorticoid synthesis stimulated in vitro with ACTH. Cholesterol content of adrenal glands under these conditions was nearly depleted, indicating maximal response to ACTH or endotoxin prior to their removal for the in vitro tests. In an effort to account physiologically for the manner in which endotoxin suppresses or prevents the rise in urinary nitrogen excreted in response to ACTH, blood non-protein nitrogen levels (NPN) were determined. The following experimental conditions resulted in increased urinary nitrogen excretion but did not alter blood NPN: cortisone given alone or at the same time as endotoxin; ACTH alone; dichloroisoproterenol (DCI) given concurrently with endotoxin; and lactalbumin digest injected intraperitoneally. Increases (2- to 3-fold) in blood NPN were observed when endotoxin was given alone, concurrently with ACTH, or 3 hours prior to cortisone, DCI, or lactalbumin digest. Urinary nitrogen excretion showed no change under these conditions. The elevation in blood NPN in endotoxin-poisoned mice was found to be due almost entirely to urea nitrogen and not to amino acid nitrogen or to other nitrogenous wastes. Blood clearance of mulin, phenol red excretion, and urea elimination were each determined in control and in endotoxin-poisoned mice. The latter mice showed impaired renal function. Treatment with diuretics (diuril and aminophylline) failed to alter oliguria or elevated blood NPN. Hydergine treatment was also without effect. Total carcass NPN and urinary nitrogen excretion data were combined to give a picture of total protein catabolized by mice under different experimental conditions. Cortisone injected at the same time as endotoxin or 3 hours later resulted in the same increase in total NPN. However, in the former case all the extra nitrogen appeared in the urine while in the latter it remained in the carcass. ACTH given alone or concurrently with endotoxin produced large increases in total NPN but less in poisoned mice. This suggests that endotoxin suppresses adrenal response to ACTH. Urea injected into normal mice was recovered quantitatively in urine while in endotoxin-poisoned mice it was partitioned between carcass and urine. Elevation of carcass NPN by means of urea injections failed to alter the lethality of an LD70 dose of endotoxin. PMID:19867206

  11. Pre-donation cognitions of potential living organ donors: the development of the Donation Cognition Instrument in potential kidney donors.

    PubMed

    Wirken, Lieke; van Middendorp, Henriët; Hooghof, Christina W; Sanders, Jan-Stephan F; Dam, Ruth E; van der Pant, Karlijn A M I; Berendsen, Elsbeth C M; Wellink, Hiske; Dackus, Henricus J A; Hoitsma, Andries J; Hilbrands, Luuk B; Evers, Andrea W M

    2017-03-01

    Cognitions surrounding living organ donation, including the motivation to donate, expectations of donation and worries about donation, are relevant themes during living donor evaluation. However, there is no reliable psychometric instrument assessing all these different cognitions. This study developed and validated a questionnaire to assess pre-donation motivations, expectations and worries regarding donation, entitled the Donation Cognition Instrument (DCI). Psychometric properties of the DCI were examined using exploratory factor analysis for scale structure and associations with validated questionnaires for construct validity assessment. From seven Dutch transplantation centres, 719 potential living kidney donors were included. The DCI distinguishes cognitions about donor benefits, recipient benefits, idealistic incentives, gratitude and worries about donation (Cronbach's alpha 0.76-0.81). Scores on pre-donation cognitions differed with regard to gender, age, marital status, religion and donation type. With regard to construct validity, the DCI was moderately correlated with expectations regarding donor's personal well-being and slightly to moderately to health-related quality of life. The DCI is found to be a reliable instrument assessing cognitions surrounding living organ donation, which might add to pre-donation quality of life measures in facilitating psychosocial donor evaluation by healthcare professionals. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  12. MicroRNA Changes in Cerebrospinal Fluid After Subarachnoid Hemorrhage.

    PubMed

    Bache, Søren; Rasmussen, Rune; Rossing, Maria; Laigaard, Finn Pedersen; Nielsen, Finn Cilius; Møller, Kirsten

    2017-09-01

    Delayed cerebral ischemia (DCI) accounts for a major part of the morbidity and mortality after aneurysmal subarachnoid hemorrhage (SAH). MicroRNAs (miRNAs) are pathophysiologically involved in acute cerebral ischemia. This study compared miRNA profiles in cerebrospinal fluid from neurologically healthy patients, as well as SAH patients with and without subsequent development of DCI. In a prospective case-control study of SAH patients treated with external ventricular drainage and neurologically healthy patients, miRNA profiles in cerebrospinal fluid were screened and validated using 2 different high-throughput real-time quantification polymerase chain reaction techniques. The occurrence of DCI was documented in patient charts and subsequently reviewed independently by 2 physicians. MiRNA profiles from 27 SAH patients and 10 neurologically healthy patients passed quality control. In the validation, 66 miRNAs showed a relative increase in cerebrospinal fluid from SAH patients compared with neurologically healthy patients ( P <0.001); 2 (miR-21 and miR-221) showed a relative increase in SAH patients with DCI compared with those without ( P <0.05) in both the screening and validation. SAH is associated with marked changes in the cerebrospinal fluid miRNA profile. These changes could be associated to the development of DCI. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01791257. © 2017 The Authors.

  13. Ineffective esophageal motility phenotypes following fundoplication in gastroesophageal reflux disease.

    PubMed

    Mello, M D; Shriver, A R; Li, Y; Patel, A; Gyawali, C P

    2016-02-01

    Ineffective esophageal motility (IEM) is associated with reflux disease, but its natural history is unclear. We evaluated patients undergoing repeat esophageal high resolution manometry (HRM) for symptomatic presentations after antireflux surgery (ARS) to understand the progression of IEM. Patients with repeat HRM after ARS were included. Ineffective esophageal motility was diagnosed if ≥5 sequences had distal contractile integral (DCI) <450 mmHg cm s. Augmentation of DCI following multiple rapid swallows (MRS) was assessed. The esophagogastric junction (EGJ) was interrogated using the EGJ contractile integral (EGJ-CI). Esophageal motor function was compared between patients with and without IEM. Sixty-eight patients (53.9 ± 1.8 years, 66.2% female) had pre- and post-ARS HRM studies 2.1 ± 0.19 years apart. Esophagogastric junction-CI augmented by a mean of 26.3% following ARS. Four IEM phenotypes were identified: 14.7% had persistent IEM, 8.8% resolved IEM after ARS, 19.1% developed new IEM, and 57.4% had no IEM at any point. Patients with IEM had a lower DCI pre- and post-ARS, lower pre-ARS EGJ CI, and lower pre-ARS-integrated relaxation pressure (p ≤ 0.02 for all comparisons); presenting symptoms and other EGJ metrics were similar (p ≥ 0.08 for all comparisons). The IEM phenotypes could be predicted by MRS DCI response patterns (p = 0.008 across groups); patients with persistent IEM had the least DCI augmentation (p = 0.007 compared to no IEM), while those who resolved IEM had DCI augmentation comparable to no IEM (p = 0.08). Distinct phenotypes of IEM exist among symptomatic reflux patients following ARS. Provocative testing with MRS may help identify these phenotypes pre-ARS. © 2015 John Wiley & Sons Ltd.

  14. Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

    PubMed

    Roncali, Emilie; Phipps, Jennifer E; Marcu, Laura; Cherry, Simon R

    2012-10-21

    In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2×2×20 mm(3) phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors.

  15. Pulse Shape Discrimination and Classification Methods for Continuous Depth of Interaction Encoding PET Detectors

    PubMed Central

    Roncali, Emilie; Phipps, Jennifer E.; Marcu, Laura; Cherry, Simon R.

    2012-01-01

    In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2 × 2 × 20 mm3 phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors. PMID:23010690

  16. Protection against the synaptic targeting and toxicity of Alzheimer's-associated Aβ oligomers by insulin mimetic chiro-inositols

    PubMed Central

    Pitt, Jason; Thorner, Michael; Brautigan, David; Larner, Joseph; Klein, William L.

    2013-01-01

    Alzheimer's disease (AD) is a progressive dementia that correlates highly with synapse loss. This loss appears due to the synaptic accumulation of toxic Aβ oligomers (ADDLs), which damages synapse structure and function. Although it has been reported that oligomer binding and toxicity can be prevented by stimulation of neuronal insulin signaling with PPARγ agonists, these agonists have problematic side effects. We therefore investigated the therapeutic potential of chiro-inositols, insulin-sensitizing compounds safe for human consumption. Chiro-inositols have been studied extensively for treatment of diseases associated with peripheral insulin resistance, but their insulin mimetic function in memory-relevant central nervous system (CNS) cells is unknown. Here we demonstrate that mature cultures of hippocampal neurons respond to d-chiro-inositol (DCI), pinitol (3-O-methyl DCI), and the inositol glycan INS-2 (pinitol β-1-4 galactosamine) with increased phosphorylation in key upstream components in the insulin-signaling pathway (insulin receptor, insulin receptor substrate-1, and Akt). Consistent with insulin stimulation, DCI treatment promotes rapid withdrawal of dendritic insulin receptors. With respect to neuroprotection, DCI greatly enhances the ability of insulin to prevent ADDL-induced synapse damage (EC50 of 90 nM). The mechanism comprises inhibition of oligomer binding at synapses and requires insulin/IGF signaling. DCI showed no effects on Aβ oligomerization. We propose that inositol glycans and DCI, a compound already established as safe for human consumption, have potential as AD therapeutics by protecting CNS synapses against Aβ oligomers through their insulin mimetic activity.—Pitt, J., Thorner, M., Brautigan, D., Larner, J., Klein, W. L. Protection against the synaptic targeting and toxicity of Alzheimer's-associated Aβ oligomers by insulin mimetic chiro-inositols. PMID:23073831

  17. Changes in esophageal motility after endoscopic submucosal dissection for superficial esophageal cancer: a high-resolution manometry study.

    PubMed

    Takahashi, K; Sato, Y; Takeuchi, M; Sato, H; Nakajima, N; Ikarashi, S; Hayashi, K; Mizuno, K-I; Honda, Y; Hashimoto, S; Yokoyama, J; Terai, S

    2017-11-01

    The effect of endoscopic submucosal dissection (ESD) on esophageal motility remains unknown. Therefore, the aim of this study is to elucidate changes in esophageal motility after ESD along with the cause of dysphagia using high-resolution manometry (HRM). This is a before-and-after trial of the effect of ESD on the esophageal motility. Twenty patients who underwent ESD for superficial esophageal carcinoma were enrolled in this study. Patients filled out a questionnaire about dysphagia and underwent HRM before and after ESD. Results before and after ESD were compared. Data were obtained from 19 patients. The number of patients who complained of dysphagia before and after ESD was 1/19 (5.3%) and 6/19 (31.6%), respectively (P = 0.131). Scores from the five-point Likert scale before and after ESD were 0.1 ± 0.5 and 1.0 ± 1.6, respectively (P = 0.043). The distal contractile integral (DCI) before and after ESD and the number of failed, weak, or fragmented contractions were not significantly different. However, in five patients with circumferential ESD, DCI was remarkably decreased and the frequency of fail, weak, or fragmented contractions increased. Univariate regression analysis showed a relatively strong inverse correlation of ΔDCI with the circumferential mucosal defect ratio {P < 0.01, standardized regression coefficient (r) = -0.65}, the number of stricture preventions (P < 0.01, r = -0.601), and the number of stricture resolutions (P < 0.01, r = -0.77). This HRM study showed that impairment of esophageal motility could be caused by ESD. The impairment of esophageal motility was conspicuous, especially in patients with circumferential ESD and subsequent procedures such as endoscopic triamcinolone injection and endoscopic balloon dilatation. Impaired esophageal motility after ESD might explain dysphagia. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Results of an International Survey on the Investigation and Endovascular Management of Cerebral Vasospasm and Delayed Cerebral Ischemia.

    PubMed

    Hollingworth, Milo; Chen, Peng Roc; Goddard, Antony J P; Coulthard, Alan; Söderman, Michael; Bulsara, Ketan R

    2015-06-01

    Delayed cerebral ischemia (DCI) is a major cause of morbidity and mortality in aneurysmal subarachnoid hemorrhage. Endovascular management of this condition offers a new hope in preventing adverse outcome; however, a uniform standard of practice is lacking owing to a paucity of clinical trials. We conducted an international survey on the use of investigative and endovascular techniques in the treatment of DCI to assess the variability of current practice. Neurovascular neurosurgeons and neuroradiologists were contacted through professional societies from America, United Kingdom, Europe, and Australasia. Members were invited to complete a 13-item questionnaire regarding screening techniques, first-line and second-line therapies in endovascular intervention, and the role of angioplasty. Answers were compared using χ(2) testing for nonparametric data. Data from 344 respondents from 32 countries were analyzed: 167 non-United States and 177 U.S. More than half of all clinicians had 10+ years of experience in units with a mixture of higher and lower case volumes. Daily transcranial Doppler ultrasonography was the most commonly used screening technique by both U.S. (70%) and non-U.S. (53%) practitioners. Verapamil was the most common first-line therapy in the United States, whereas nimodipine was most popular in non-U.S. countries. Angioplasty was performed by 83% of non-U.S. and 91% of U.S. clinicians in the treatment of vasospasm; however, more U.S. clinicians reported using angioplasty for distal vasospasm. Treatment practices for DCI vary considerably, with the greatest variability in the choice of agent for intra-arterial therapy. Our data demonstrate the wide variation of approaches in use at present. However, without further clinical trials and development of a uniform standard of best practice, variability in treatment and outcome for DCI is likely to continue. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. MicroRNA Changes in Cerebrospinal Fluid After Subarachnoid Hemorrhage

    PubMed Central

    Rasmussen, Rune; Rossing, Maria; Laigaard, Finn Pedersen; Nielsen, Finn Cilius; Møller, Kirsten

    2017-01-01

    Background and Purpose— Delayed cerebral ischemia (DCI) accounts for a major part of the morbidity and mortality after aneurysmal subarachnoid hemorrhage (SAH). MicroRNAs (miRNAs) are pathophysiologically involved in acute cerebral ischemia. This study compared miRNA profiles in cerebrospinal fluid from neurologically healthy patients, as well as SAH patients with and without subsequent development of DCI. Methods— In a prospective case–control study of SAH patients treated with external ventricular drainage and neurologically healthy patients, miRNA profiles in cerebrospinal fluid were screened and validated using 2 different high-throughput real-time quantification polymerase chain reaction techniques. The occurrence of DCI was documented in patient charts and subsequently reviewed independently by 2 physicians. Results— MiRNA profiles from 27 SAH patients and 10 neurologically healthy patients passed quality control. In the validation, 66 miRNAs showed a relative increase in cerebrospinal fluid from SAH patients compared with neurologically healthy patients (P<0.001); 2 (miR-21 and miR-221) showed a relative increase in SAH patients with DCI compared with those without (P<0.05) in both the screening and validation. Conclusions— SAH is associated with marked changes in the cerebrospinal fluid miRNA profile. These changes could be associated to the development of DCI. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT01791257. PMID:28768799

  20. Decompression illness in divers treated in Auckland, New Zealand, 1996-2012.

    PubMed

    Haas, Rachel M; Hannam, Jacqueline A; Sames, Christopher; Schmidt, Robert; Tyson, Andrew; Francombe, Marion; Richardson, Drew; Mitchell, Simon J

    2014-03-01

    The treatment of divers for decompression illness (DCI) in Auckland, New Zealand, has not been described since 1996, and subsequent trends in patient numbers and demographics are unmeasured. This was a retrospective audit of DCI cases requiring recompression in Auckland between 01 January 1996 and 31 December 2012. Data describing patient demographics, dive characteristics, presentation of DCI and outcomes were extracted from case notes and facility databases. Trends in annual case numbers were evaluated using Spearman's correlation coefficients (ρ) and compared with trends in entry-level diver certifications. Trends in patient demographics and delay between diving and recompression were evaluated using regression analyses. There were 520 DCI cases. Annual caseload decreased over the study period (ρ = 0.813, P < 0.0001) as did entry level diving certifications in New Zealand (ρ = 0.962, P < 0.0001). Mean diver age was 33.6 (95% confidence limits (CI) 32.7 to 34.5) years and age increased (P < 0.0001) over the study period. Median (range) delay to recompression was 2.06 (95% CI 0.02 to 23.6) days, and delay declined over the study period (P = 0.005). Numbers of DCI cases recompressed in Auckland have declined significantly over the last 17 years. The most plausible explanation is declining diving activity but improvements in diving safety cannot be excluded. The delay between diving and recompression has reduced.

  1. Dynamic cervical stabilization: a multicenter study.

    PubMed

    Matgé, Guy; Buddenberg, Peter; Eif, Marcus; Schenke, Holger; Herdmann, Joerg

    2015-12-01

    The dynamic cervical implant (DCI) is a novel motion-preserving concept for the treatment of degenerative cervical disorders. The aim of this prospective clinical study was to validate the concept and analyse clinical and radiological performance of the implant. One hundred seventy-five consecutive patients with degenerative cervical disorders, median age, 47 years, were treated with discectomy and DCI, and followed for 2 years. Clinical outcome was evaluated with the Neck Disability Index (NDI), the SF-12, and visual analogue scale (VAS) assessment of arm and neck pain. Range of motion (ROM) and cervical alignment were analysed using radiographic imaging. All clinical outcome measures--VAS neck and arm pain, NDI, and SF-12 mental and physical component summaries--improved significantly after surgery (each p < 0.001) and remained stable over the whole observation period. The ROM (flexion/extension) at the level treated with DCI was slightly reduced, but no significant changes could be verified at the adjacent levels. Six surgery or device-related adverse events were documented during the study. Good clinical and excellent radiological outcomes demonstrate that DCI is a safe and efficient treatment option in patients with degenerative cervical disorders.

  2. The evolution of invasive cerebral vasospasm treatment in patients with spontaneous subarachnoid hemorrhage and delayed cerebral ischemia-continuous selective intracarotid nimodipine therapy in awake patients without sedation.

    PubMed

    Paľa, Andrej; Schneider, Max; Brand, Christine; Pedro, Maria Teresa; Özpeynirci, Yigit; Schmitz, Bernd; Wirtz, Christian Rainer; Kapapa, Thomas; König, Ralph; Braun, Michael

    2018-05-26

    Cerebral vasospasm (CV) and delayed cerebral ischemia (DCI) are major factors that limit good outcome in patients with spontaneous subarachnoid hemorrhage (SAH). Continuous therapy with intra-arterial calcium channel blockers has been introduced as a new step in the invasive treatment cascade of CV and DCI. Sedation is routinely necessary for this procedure. We report about the feasibility to apply this therapy in awake compliant patients without intubation and sedation. Out of 67 patients with invasive endovascular treatment of cerebral vasospasm due to spontaneous SAH, 5 patients underwent continuous superselective intracarotid nimodipine therapy without intubation and sedation. Complications, neurological improvement, and outcome at discharge were summarized. Very good outcome was achieved in all 5 patients. The Barthel scale was 100 and the modified Rankin scale 0-1 in all cases at discharge. We found no severe complications and excellent neurological monitoring was possible in all cases due to patients' alert status. Symptoms of DCI resolved within 24 h in all 5 cases. We could demonstrate the feasibility and safety of selective intracarotid arterial nimodipine treatment in awake, compliant patients with spontaneous SAH and symptomatic CV and DCI. Using this method, an excellent monitoring of neurological function as well as early detection of other complications is possible. It might be an important step in the risk reduction of invasive CV therapy to improve the outcome with CV and DCI after SAH in selected patients.

  3. Lactobacillus vespulae sp. nov., isolated from gut of a queen wasp (Vespula vulgaris).

    PubMed

    Hoang, Van-An; Kim, Yeon-Ju; Nguyen, Ngoc-Lan; Kim, Si-Kwan; Yang, Deok-Chun

    2015-10-01

    A Gram-stain-positive, oxidase- and catalase-negative, rod-shaped, facultatively anaerobic bacterial strain, DCY75T, was isolated from a queen wasp (Vespula vulgaris). Growth occurred at 4–37 °C (optimum, 30 °C), at pH 3.5–8.0 (optimum, pH 5.0–6.0) and with ≤ 7.0 % (w/v) NaCl. Strain DCY75T produced gas during growth on glucose. Phylogenetic analysis based on 16S rRNA gene sequences indicated that strain DCY75T belonged to the genus Lactobacillus and was closely related to Lactobacillus sanfranciscensis ATCC 27651T and Lactobacillus lindneri DSM 20690T at sequence similarities of 96.7 and 96.4 %, respectively. A comparison of two housekeeping genes, pheS and rpoA, revealed that strain DCT75T was well separated from other species of the genus Lactobacillus. Strain DCY75T produced d- and l-lactic acid isomers in a ratio of 22.5 : 77.5 (v/v). The major fatty acids were summed feature 8 (comprising C18 :  1ω7c and/or C18 : 1ω6c), C16 : 0, C18 : 1ω9c and C18 : 0.The peptidoglycan structure was of the A4α (l-Lys–d-Asp) type. Cell-wall sugars were glucose, galactose and ribose. The DNA G+C content was 35.5 ± 1.3 mol%. Based on phenotypic and genotypic properties, strain DCY75T represents a novel species of the genus Lactobacillus, for which the name Lactobacillus vespulae sp. nov. is proposed. The type strain is DCY75T ( = KCTC 21023T = JCM 19742T).

  4. Socio-ecological perspective of older age life expectancy: income, gender inequality, and financial crisis in Europe.

    PubMed

    Kim, Jong In; Kim, Gukbin

    2017-08-18

    Population is aging rapidly in Europe. Older age life expectancy (OLE) can be influenced by country-level depth of credit information (DCI) as an indicator of financial crisis, gross national income (GNI) per capita, and gender inequality index (GII). These factors are key indicators of socio-ecological inequality. They can be used to develop strategies to reduce country-level health disparity. The objective of this study was to confirm the relationship between socio-ecological factors and OLE in Europe. Data were obtained from World Bank, WHO, and UN database for 34 Europe countries. Associations between socio-ecological factors and OLE were assessed with Pearson correlation coefficients and three regression models. These models assumed that appropriate changes in country-level strategies of healthy aging would produce changes in GNI per capital as personal perspective, GII in social environment perspective, and DCI in public policy perspective to implement socio-ecological changes. Hierarchal linear regression was used for final analysis. Although OLE (women and men) had significant negative correlation with GII (gender inequality index, r = - 0.798, p = 0.001), it had positive correlations with GNI (gross national income per capita, r = 0.834, p = 0.001) and DCI (depth of credit information index, r = 0.704, p = 0.001) levels caused by financial crisis. Higher levels GNI and DCI but lower GII were found to be predictors of OLE (women and men) (R 2  = 0.804, p < 0.001). Factors affecting older age life expectancy in Europe were identified from socio-ecological perspective. Socio-ecological indicators (GII, GNI, and DCI) in Europe appear to have a latent effect on OLE levels. Thus, country-level strategies of successful aging in Europe should target socio-ecological factors such as GII, GNI, and DCI value.

  5. Global model comparison of heterogeneous ice nucleation parameterizations in mixed phase clouds

    NASA Astrophysics Data System (ADS)

    Yun, Yuxing; Penner, Joyce E.

    2012-04-01

    A new aerosol-dependent mixed phase cloud parameterization for deposition/condensation/immersion (DCI) ice nucleation and one for contact freezing are compared to the original formulations in a coupled general circulation model and aerosol transport model. The present-day cloud liquid and ice water fields and cloud radiative forcing are analyzed and compared to observations. The new DCI freezing parameterization changes the spatial distribution of the cloud water field. Significant changes are found in the cloud ice water fraction and in the middle cloud fractions. The new DCI freezing parameterization predicts less ice water path (IWP) than the original formulation, especially in the Southern Hemisphere. The smaller IWP leads to a less efficient Bergeron-Findeisen process resulting in a larger liquid water path, shortwave cloud forcing, and longwave cloud forcing. It is found that contact freezing parameterizations have a greater impact on the cloud water field and radiative forcing than the two DCI freezing parameterizations that we compared. The net solar flux at top of atmosphere and net longwave flux at the top of the atmosphere change by up to 8.73 and 3.52 W m-2, respectively, due to the use of different DCI and contact freezing parameterizations in mixed phase clouds. The total climate forcing from anthropogenic black carbon/organic matter in mixed phase clouds is estimated to be 0.16-0.93 W m-2using the aerosol-dependent parameterizations. A sensitivity test with contact ice nuclei concentration in the original parameterization fit to that recommended by Young (1974) gives results that are closer to the new contact freezing parameterization.

  6. Phenotypes and clinical context of hypercontractility in high resolution esophageal pressure topography (EPT)

    PubMed Central

    Roman, Sabine; Pandolfino, John E; Chen, Joan; Boris, Lubomyr; Luger, Daniel; Kahrilas, Peter J

    2013-01-01

    Backgrounds & Aims This study aimed to refine the criteria for esophageal hypercontractility in high resolution esophageal pressure topography (EPT) and examine the clinical context in which it occurs. Subjects & Methods 72 control subjects were used to define the threshold for hypercontractility as a distal contractile integral (DCI) greater than observed in normals. 2,000 consecutive EPT studies were reviewed to find patients exceeding this threshold. Concomitant EPT and clinical variables were explored. Results The greatest DCI value observed in any swallow among the control subjects was 7,732 mmHg-s-cm; the threshold for hypercontractility was established as a swallow with DCI >8,000 mmHg-s-cm. 44 patients were identified with a median maximal DCI of 11,077 mmHg-s-cm, all with normal contractile propagation and normal distal contractile latency, thereby excluding achalasia and distal esophageal spasm. Hypercontractility was associated with multipeaked contractions in 82% of instances leading to the name Jackhammer Esophagus . Dysphagia was the dominant symptom although subsets of patients had hypercontractility in the context of EGJ outflow obstruction, reflux disease, or as an apparent primary motility disorder. Conclusion We describe an extreme phenotype of hypercontractility characterized in EPT by the occurrence of at least a single contraction with DCI > 8,000 mmHg-s-cm, a value not encountered in control subjects. This phenomenon, branded Jackhammer Esophagus was usually accompanied by dysphagia and occurred both in association with other esophageal pathology (EGJ outflow obstruction, reflux disease) or as an isolated motility disturbance. Further studies are required to define the pathophysiology and treatment of this disorder. PMID:21931377

  7. Different CT perfusion algorithms in the detection of delayed cerebral ischemia after aneurysmal subarachnoid hemorrhage.

    PubMed

    Cremers, Charlotte H P; Dankbaar, Jan Willem; Vergouwen, Mervyn D I; Vos, Pieter C; Bennink, Edwin; Rinkel, Gabriel J E; Velthuis, Birgitta K; van der Schaaf, Irene C

    2015-05-01

    Tracer delay-sensitive perfusion algorithms in CT perfusion (CTP) result in an overestimation of the extent of ischemia in thromboembolic stroke. In diagnosing delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH), delayed arrival of contrast due to vasospasm may also overestimate the extent of ischemia. We investigated the diagnostic accuracy of tracer delay-sensitive and tracer delay-insensitive algorithms for detecting DCI. From a prospectively collected series of aSAH patients admitted between 2007-2011, we included patients with any clinical deterioration other than rebleeding within 21 days after SAH who underwent NCCT/CTP/CTA imaging. Causes of clinical deterioration were categorized into DCI and no DCI. CTP maps were calculated with tracer delay-sensitive and tracer delay-insensitive algorithms and were visually assessed for the presence of perfusion deficits by two independent observers with different levels of experience. The diagnostic value of both algorithms was calculated for both observers. Seventy-one patients were included. For the experienced observer, the positive predictive values (PPVs) were 0.67 for the delay-sensitive and 0.66 for the delay-insensitive algorithm, and the negative predictive values (NPVs) were 0.73 and 0.74. For the less experienced observer, PPVs were 0.60 for both algorithms, and NPVs were 0.66 for the delay-sensitive and 0.63 for the delay-insensitive algorithm. Test characteristics are comparable for tracer delay-sensitive and tracer delay-insensitive algorithms for the visual assessment of CTP in diagnosing DCI. This indicates that both algorithms can be used for this purpose.

  8. Population is the main driver of war group size and conflict casualties.

    PubMed

    Oka, Rahul C; Kissel, Marc; Golitko, Mark; Sheridan, Susan Guise; Kim, Nam C; Fuentes, Agustín

    2017-12-26

    The proportions of individuals involved in intergroup coalitional conflict, measured by war group size (W), conflict casualties (C), and overall group conflict deaths (G), have declined with respect to growing populations, implying that states are less violent than small-scale societies. We argue that these trends are better explained by scaling laws shared by both past and contemporary societies regardless of social organization, where group population (P) directly determines W and indirectly determines C and G. W is shown to be a power law function of P with scaling exponent X [demographic conflict investment (DCI)]. C is shown to be a power law function of W with scaling exponent Y [conflict lethality (CL)]. G is shown to be a power law function of P with scaling exponent Z [group conflict mortality (GCM)]. Results show that, while W/P and G/P decrease as expected with increasing P, C/W increases with growing W. Small-scale societies show higher but more variance in DCI and CL than contemporary states. We find no significant differences in DCI or CL between small-scale societies and contemporary states undergoing drafts or conflict, after accounting for variance and scale. We calculate relative measures of DCI and CL applicable to all societies that can be tracked over time for one or multiple actors. In light of the recent global emergence of populist, nationalist, and sectarian violence, our comparison-focused approach to DCI and CL will enable better models and analysis of the landscapes of violence in the 21st century. Copyright © 2017 the Author(s). Published by PNAS.

  9. Population is the main driver of war group size and conflict casualties

    PubMed Central

    Oka, Rahul C.; Kissel, Marc; Golitko, Mark; Sheridan, Susan Guise; Kim, Nam C.; Fuentes, Agustín

    2017-01-01

    The proportions of individuals involved in intergroup coalitional conflict, measured by war group size (W), conflict casualties (C), and overall group conflict deaths (G), have declined with respect to growing populations, implying that states are less violent than small-scale societies. We argue that these trends are better explained by scaling laws shared by both past and contemporary societies regardless of social organization, where group population (P) directly determines W and indirectly determines C and G. W is shown to be a power law function of P with scaling exponent X [demographic conflict investment (DCI)]. C is shown to be a power law function of W with scaling exponent Y [conflict lethality (CL)]. G is shown to be a power law function of P with scaling exponent Z [group conflict mortality (GCM)]. Results show that, while W/P and G/P decrease as expected with increasing P, C/W increases with growing W. Small-scale societies show higher but more variance in DCI and CL than contemporary states. We find no significant differences in DCI or CL between small-scale societies and contemporary states undergoing drafts or conflict, after accounting for variance and scale. We calculate relative measures of DCI and CL applicable to all societies that can be tracked over time for one or multiple actors. In light of the recent global emergence of populist, nationalist, and sectarian violence, our comparison-focused approach to DCI and CL will enable better models and analysis of the landscapes of violence in the 21st century. PMID:29229847

  10. Bedside Xenon-CT Shows Lower CBF in SAH Patients with Impaired CBF Pressure Autoregulation as Defined by Pressure Reactivity Index (PRx).

    PubMed

    Johnson, Ulf; Engquist, Henrik; Howells, Tim; Nilsson, Pelle; Ronne-Engström, Elisabeth; Lewén, Anders; Rostami, Elham; Enblad, Per

    2016-08-01

    Subarachnoid hemorrhage (SAH) is a disease with a high rate of unfavorable outcome, often related to delayed cerebral ischemia (DCI), i.e., ischemic injury that develops days-weeks after onset, with a multifactorial etiology. Disturbances in cerebral pressure autoregulation, the ability to maintain a steady cerebral blood flow (CBF), despite fluctuations in systemic blood pressure, have been suggested to play a role in the development of DCI. Pressure reactivity index (PRx) is a well-established measure of cerebral pressure autoregulation that has been used to study traumatic brain injury, but not extensively in SAH. To study the relation between PRx and CBF in SAH patients, and to examine if PRx can be used to predict DCI. Retrospective analysis of prospectively collected data. PRx was calculated as the correlation coefficient between mean arterial blood pressure (MABP) and intracranial pressure (ICP) in a 5 min moving window. CBF was measured using bedside Xenon-CT (Xe-CT). DCI was diagnosed clinically. 47 poor-grade mechanically ventilated patients were studied. Patients with disturbed pressure autoregulation (high PRx values) had lower CBF, as measured by bedside Xe-CT; both in the early (day 0-3) and late (day 4-14) acute phase of the disease. PRx did not differ significantly between patients who developed DCI or not. In mechanically ventilated and sedated SAH patients, high PRx (more disturbed CBF pressure autoregulation) is associated with low CBF, both day 0-3 and day 4-14 after onset. The role of PRx as a monitoring tool in SAH patients needs further studying.

  11. Neurocardiac protection with milrinone for restoring acute cerebral hypoperfusion and delayed ischemic injury after experimental subarachnoid hemorrhage.

    PubMed

    Mutoh, Tomoko; Mutoh, Tatsushi; Sasaki, Kazumasu; Nakamura, Kazuhiro; Tatewaki, Yasuko; Ishikawa, Tatsuya; Taki, Yasuyuki

    2017-02-15

    Acute cerebral hypoperfusion following subarachnoid hemorrhage (SAH) is highly related to the pathogenesis of delayed cerebral ischemia (DCI), but the therapeutic option is poorly available. This study aimed to clarify the effect of milrinone (MIL) on cerebral blood flow (CBF) and related outcomes after experimental SAH. Twenty-seven male C57BL/6 mice were assigned to either sham surgery (SAH-sham; n=6), SAH induced by endovascular perforation (control; n=10), or SAH followed by cardiac support with intravenous MIL (n=11) performed 1.5-h after SAH induction. CBF, neurobehavioral function, occurrence of DCI were assessed by MR-continuous arterial spin labeling, daily neurological score testing, and diffusion- and T2-weighted MR images on days 1 and 3, respectively. Initial global CBF depression was notable in mice of control and MIL groups as compared to the SAH-sham group (P<0.05). MIL raised CBF in a dose-dependent manner (P<0.001), resulted in lower incidence of DCI (P=0.008) and better recovery from neurobehavioral decline than control (P<0.001). The CBF values on day 1 predicted DCI with a cut-off of 42.5ml/100g/min (82% specificity and 83% sensitivity), which was greater in mice treated with MIL than those of control (51.7 versus 37.6ml/100g/min; P<0.001). MIL improves post-SAH acute hypoperfusion that can lead to the prevention of DCI and functional worsening, acting as a neurocardiac protective agent against EBI. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Modulatory role of D-chiro-inositol (DCI) on LH and insulin secretion in obese PCOS patients.

    PubMed

    Genazzani, Alessandro D; Santagni, Susanna; Rattighieri, Erika; Chierchia, Elisa; Despini, Giulia; Marini, Giulia; Prati, Alessia; Simoncini, Tommaso

    2014-06-01

    Polycystic ovary syndrome (PCOS) is a common endocrine condition that affects fertility through oligo-ovulation, hyperandrogenism and polycystic morphology of the ovaries. Since it has been demonstrated a high incidence of insulin resistance in PCOS patients, our study aimed to evaluate the efficacy of the integrative treatment with D-chiro-inositol (DCI) (500 mg die, per os, for 12 weeks) on hormonal parameters and insulin sensitivity in a group of overweight/obese PCOS patients (body mass index; BMI > 26). After the treatment, interval several endocrine parameters improved (luteinizing hormone [LH], LH/follicle stimulating hormone [FSH], androstenedione and insulin), insulin response to oral glucose tolerance test reported the significant improvement of insulin sensitivity as well as the gonadotropin-releasing hormone (GnRH)-induced (10 µg, in bolus) LH response. BMI decreased, though no lifestyle modification was requested. When data were analyzed according to the presence or absence of first-grade diabetic relatives, PCOS patients with diabetic relatives showed greater improvement after DCI administration. In conclusion DCI administration is effective in restoring better insulin sensitivity and an improved hormonal pattern in obese hyperinsulinemic PCOS patients, in particular, in hyperinsulinemic PCOS patients who have diabetic relatives.

  13. Safety of performing a delayed anastomosis during damage control laparotomy in patients with destructive colon injuries.

    PubMed

    Ordoñez, Carlos A; Pino, Luis F; Badiel, Marisol; Sánchez, Alvaro I; Loaiza, Jhon; Ballestas, Leonardo; Puyana, Juan Carlos

    2011-12-01

    Recent studies report the safety and feasibility of performing delayed anastomosis (DA) in patients undergoing damage control laparotomy (DCL) for destructive colon injuries (DCIs). Despite accumulating experience in both civilian and military trauma, questions regarding how to best identify high-risk patients and minimize the number of anastomosis-associated complications remain. Our current practice is to perform a definitive closure of the colon during DCL, unless there is persistent acidosis, bowel wall edema, or evidence of intra-abdominal abscess. In this study, we evaluated the safety of this approach by comparing outcomes of patients with DCI who underwent definitive closure of the colon during DCL versus patients managed with colostomy with or without DCL. We performed a retrospective chart review of patients with penetrating DCI during 2003 to 2009. Severity of injury, surgical management, and clinical outcome were assessed. Sixty patients with severe gunshot wounds and three patients with stab wounds were included in the analysis. DCL was required in 30 patients, all with gunshot wounds. Three patients died within the first 48 hours, three underwent colostomy, and 24 were managed with DA. Thirty-three patients were managed with standard laparotomy: 26 patients with primary anastomosis and 7 with colostomy. Overall mortality rate was 9.5%. Three late deaths occurred in the DCL group, and only one death was associated with an anastomotic leak. Performing a DA in DCI during DCL is a reliable and feasible approach as long as severe acidosis, bowel wall edema, and/or persistent intra-abdominal infections are not present.

  14. Vasospasm on transcranial Doppler is predictive of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: a systematic review and meta-analysis.

    PubMed

    Kumar, Gyanendra; Shahripour, Reza Bavarsad; Harrigan, Mark R

    2016-05-01

    OBJECT The impact of transcranial Doppler (TCD) ultrasonography evidence of vasospasm on patient-centered clinical outcomes following aneurysmal subarachnoid hemorrhage (aSAH) is unknown. Vasospasm is known to lead to delayed cerebral ischemia (DCI) and poor outcomes. This systematic review and meta-analysis evaluates the predictive value of vasospasm on DCI, as diagnosed on TCD. METHODS MEDLINE, Scopus, the Cochrane trial register, and clinicaltrials.gov were searched through September 2014 using key words and the terms "subarachnoid hemorrhage," "aneurysm," "aneurysmal," "cerebral vasospasm," "vasospasm," "transcranial Doppler," and "TCD." Sensitivities, specificities, and positive and negative predictive values were pooled by a DerSimonian and Laird random-effects model. RESULTS Seventeen studies (n = 2870 patients) met inclusion criteria. The amount of variance attributable to heterogeneity was significant (I(2) > 50%) for all syntheses. No studies reported the impact of TCD evidence of vasospasm on functional outcome or mortality. TCD evidence of vasospasm was found to be highly predictive of DCI. Pooled estimates for TCD diagnosis of vasospasm (for DCI) were sensitivity 90% (95% confidence interval [CI] 77%-96%), specificity 71% (95% CI 51%-84%), positive predictive value 57% (95% CI 38%-71%), and negative predictive value 92% (95% CI 83%-96%). CONCLUSIONS TCD evidence of vasospasm is predictive of DCI with high accuracy. Although high sensitivity and negative predictive value make TCD an ideal monitoring device, it is not a mandated standard of care in aSAH due to the paucity of evidence on clinically relevant outcomes, despite recommendation by national guidelines. High-quality randomized trials evaluating the impact of TCD monitoring on patient-centered and physician-relevant outcomes are needed.

  15. A Propensity Score Analysis of the Impact of Dexamethasone Use on Delayed Cerebral Ischemia and Poor Functional Outcomes After Subarachnoid Hemorrhage.

    PubMed

    Mohney, Nathaniel; Williamson, Craig A; Rothman, Edward; Ball, Ron; Sheehan, Kyle M; Pandey, Aditya S; Fletcher, Jeffrey J; Jacobs, Teresa L; Thompson, B Gregory; Rajajee, Venkatakrishna

    2018-01-01

    An inflammatory response occurs after aneurysmal subarachnoid hemorrhage (aSAH) and predicts poor outcomes. Glucocorticoids suppress inflammation and promote fluid retention. Dexamethasone is often administered after aSAH for postoperative cerebral edema and refractory headache. Our objective was to examine the impact of dexamethasone use on functional outcomes and delayed cerebral ischemia (DCI) after aSAH. Patients with aSAH admitted between 2010 and 2015 were included; the data source was a single-center subarachnoid hemorrhage registry. The intervention of interest was a dexamethasone taper used <7 days from ictus. The primary outcome was poor discharge functional outcome, with a modified Rankin Scale score >3. Other outcomes included DCI and infection. A propensity score for use of dexamethasone was calculated using a logistic regression model that included potential predictors of dexamethasone use and outcome. The impact of dexamethasone on outcomes of interest was calculated and the propensity score was controlled for. A total of 440 patients with subarachnoid hemorrhage were admitted during the study period and 309 met eligibility criteria. Dexamethasone was administered in 101 patients (33%). A total of 127 patients (41%) had a discharge modified Rankin Scale score >3, 105 (34%) developed DCI, and 94 (30%) developed an infection. After propensity score analysis, dexamethasone use was associated with a significant reduction in poor functional outcomes (odds ratio [OR], 0.35; 95% confidence interval [CI], 0.19-0.66) but showed no significant association with DCI (OR, 0.93; 95% CI, 0.53-1.64) or infection (OR, 0.60; 95% CI, 0.34-1.06). Dexamethasone use after aSAH was associated with a reduction in poor functional outcomes at discharge but not DCI, controlling for predictors of dexamethasone use. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. The Association Between Spontaneous Hyperventilation, Delayed Cerebral Ischemia, and Poor Neurological Outcome in Patients with Subarachnoid Hemorrhage.

    PubMed

    Williamson, Craig A; Sheehan, Kyle M; Tipirneni, Renuka; Roark, Christopher D; Pandey, Aditya S; Thompson, B Gregory; Rajajee, Venkatakrishna

    2015-12-01

    The frequency and associations of spontaneous hyperventilation in subarachnoid hemorrhage (SAH) are unknown. Because hyperventilation decreases cerebral blood flow, it may exacerbate delayed cerebral ischemia (DCI) and worsen neurological outcome. This is a retrospective analysis of data from a prospectively collected cohort of SAH patients at an academic medical center. Spontaneous hyperventilation was defined by PaCO2 <35 mmHg and pH >7.45 and subdivided into moderate and severe groups. Clinical and demographic characteristics of patients with and without spontaneous hyperventilation were compared using χ (2) or t tests. Bivariate and multivariable logistic regression analyses were conducted to examine the association of moderate and severe hyperventilation with DCI and discharge neurological outcome. Of 207 patients, 113 (55 %) had spontaneous hyperventilation. Spontaneously hyperventilating patients had greater illness severity as measured by the Hunt-Hess, World Federation of Neurosurgical Societies (WFNS), and SAH sum scores. They were also more likely to develop the following complications: pneumonia, neurogenic myocardial injury, systemic inflammatory response syndrome (SIRS), radiographic vasospasm, DCI, and poor neurological outcome. In a multivariable logistic regression model including age, gender, WFNS, SAH sum score, pneumonia, neurogenic myocardial injury, etiology, and SIRS, only moderate [odds ratio (OR) 2.49, 95 % confidence interval (CI) 1.10-5.62] and severe (OR 3.12, 95 % CI 1.30-7.49) spontaneous hyperventilation were associated with DCI. Severe spontaneous hyperventilation (OR 4.52, 95 % CI 1.37-14.89) was also significantly associated with poor discharge outcome in multivariable logistic regression analysis. Spontaneous hyperventilation is common in SAH and is associated with DCI and poor neurological outcome.

  17. Early Magnesium Treatment After Aneurysmal Subarachnoid Hemorrhage: Individual Patient Data Meta-Analysis.

    PubMed

    Dorhout Mees, Sanne M; Algra, Ale; Wong, George K C; Poon, Wai S; Bradford, Celia M; Saver, Jeffrey L; Starkman, Sidney; Rinkel, Gabriel J E; van den Bergh, Walter M; van Kooten, F; Dirven, C M; van Gijn, J; Vermeulen, M; Rinkel, G J E; Boet, R; Chan, M T V; Gin, T; Ng, S C P; Zee, B C Y; Al-Shahi Salman, R; Boiten, J; Kuijsten, H; Lavados, P M; van Oostenbrugge, R J; Vandertop, W P; Finfer, S; O'Connor, A; Yarad, E; Firth, R; McCallister, R; Harrington, T; Steinfort, B; Faulder, K; Assaad, N; Morgan, M; Starkman, S; Eckstein, M; Stratton, S J; Pratt, F D; Hamilton, S; Conwit, R; Liebeskind, D S; Sung, G; Kramer, I; Moreau, G; Goldweber, R; Sanossian, N

    2015-11-01

    Delayed cerebral ischemia (DCI) is an important cause of poor outcome after aneurysmal subarachnoid hemorrhage (SAH). Trials of magnesium treatment starting <4 days after symptom onset found no effect on poor outcome or DCI in SAH. Earlier installment of treatment might be more effective, but individual trials had not enough power for such a subanalysis. We performed an individual patient data meta-analysis to study whether magnesium is effective when given within different time frames within 24 hours after the SAH. Patients were divided into categories according to the delay between symptom onset and start of the study medication: <6, 6 to 12, 12 to 24, and >24 hours. We calculated adjusted risk ratios with corresponding 95% confidence intervals for magnesium versus placebo treatment for poor outcome and DCI. We included 5 trials totaling 1981 patients; 83 patients started treatment<6 hours. For poor outcome, the adjusted risk ratios of magnesium treatment for start <6 hours were 1.44 (95% confidence interval, 0.83-2.51); for 6 to 12 hours 1.03 (0.65-1.63), for 12 to 24 hours 0.84 (0.65-1.09), and for >24 hours 1.06 (0.87-1.31), and for DCI, <6 hours 1.76 (0.68-4.58), for 6 to 12 hours 2.09 (0.99-4.39), for 12 to 24 hours 0.80 (0.56-1.16), and for >24 hours 1.08 (0.88-1.32). This meta-analysis suggests no beneficial effect of magnesium treatment on poor outcome or DCI when started early after SAH onset. Although the number of patients was small and a beneficial effect cannot be definitively excluded, we found no justification for a new trial with early magnesium treatment after SAH. © 2015 American Heart Association, Inc.

  18. Competition Level Not Associated With Diet Quality in Marching Artists.

    PubMed

    McConnell, Colleen; McPherson, Alyssa; Woolf, Kathleen

    2018-01-01

    Marching artists are a unique group of athletes whose performance can be influenced by nutrition. Because physical demands are thought to be moderate to high, adequate energy and a variety of nutrient-dense foods are needed. The purpose of this study was to examine diet quality, physical activity, and eating behavior of marching artists across elite and nonelite competition levels. This cross-sectional analysis used the validated National Cancer Institute Diet History Questionnaire II, International Physical Activity Questionnaire, and Eating Behavior Patterns Questionnaire. Diet quality was assessed using the Healthy Eating Index (HEI) 2010. Marching artists who participated in marching band in 2015 were eligible. Those in Drum Corps International (DCI) were considered part of the elite level; all others were considered nonelite. Chi-square analyses assessed associations between categorical variables and competition level, and independent sample t-tests assessed differences between continuous variables among competition level. Participants (n = 323) included 228 (71%) DCI members and 95 (29%) non-DCI members who reported a mean age of 19.8 ± 1.9 years. DCI members reported higher physical activity levels (p < 0.001) and fewer meal-skipping behaviors compared to non-DCI members (p < 0.001). The overall mean HEI score was 58.8 ± 10.3, with no difference between competition levels. Only one participant overall (<1%) met the recommended intake level of whole grains. Additionally, 2% of participants met the sodium restriction recommendation and 7% met the empty calorie upper limit. Suboptimal diet quality combined with high levels of physical activity is a problem for marching artists that should be addressed through carefully planned interventions.

  19. Evaluating the risk of decompression sickness for a yo-yo dive using a rat model.

    PubMed

    Ofir, Dror; Yanir, Yoav; Abramovich, Amir; Bar, Ronen; Arieli, Yehuda

    2016-01-01

    The frequent ascents made during yo-yo diving may contribute to gas bubble clearance but paradoxically may also increase the risk of central nervous system decompression illness (DCI). We evaluated the risk of DCI due to yo-yo dives with very short surface intervals, using a controlled animal model. Dives were conducted on air to a depth of 90 meters (10 atmospheres absolute) for 32 minutes of bottom time, at a descent/ascent rate of 10 meters/ minute. Sprague-Dawley rats weighing ~ 300 grams were divided randomly into three groups. Group A performed a square dive protocol without any surface intervals, Group B conducted a protocol that included two surface intervals during the dive, and Group C performed a protocol with three surface intervals. Ascent/descent rate for surface intervals, each lasting one minute, was also 10 meters/minute. Manifestations of DCI were observed in 13 of 16 animals in Group A (81.3%), six of 12 in Group B (58.3%), and two of 12 in Group C (16.7%). Mortality rates were similar in all groups. Surface intervals during dives breathing air significantly reduced DCI risk in the rat. Further studies are required using a larger animal model to reinforce the results of the present investigation.

  20. Importance of Early Postoperative Body Temperature Management for Treatment of Subarachnoid Hemorrhage.

    PubMed

    Suehiro, Eiichi; Sadahiro, Hirokazu; Goto, Hisaharu; Oku, Takayuki; Oka, Fumiaki; Fujiyama, Yuichi; Shirao, Satoshi; Yoneda, Hiroshi; Koizumi, Hiroyasu; Ishihara, Hideyuki; Suzuki, Michiyasu

    2016-06-01

    The importance of acute-phase brain temperature management is widely accepted for prevention of exacerbation of brain damage by a high body temperature. In this study, we investigated the influence of body temperature in the early postoperative period on the outcomes of 62 patients with subarachnoid hemorrhage who were admitted to our department. Body temperature was measured from day 4 to day 14 after onset. The patients were divided into those treated with surgical clipping (clip group) and coil embolization (coil group), those graded I-III (mild) and IV-V (severe) based on the Hunt & Hess classification on admission, those with and without development of delayed cerebral ischemia (DCI), and those with favorable and poor outcomes. Body temperatures throughout the hospital stay were compared in each group. There was no significant difference in body temperature between the clip and coil groups or between the mild and severe groups, but body temperature was significantly higher in patients with DCI compared to those without DCI, and in patients with a poor outcome compared to those with a favorable outcome. Fever in the early postoperative period of subarachnoid hemorrhage is associated with development of DCI and a poor outcome. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. A Teaching Model for Scaffolding 4th Grade Students' Scientific Explanation Writing

    NASA Astrophysics Data System (ADS)

    Yang, Hsiu-Ting; Wang, Kuo-Hua

    2014-08-01

    Improving students scientific explanations is one major goal of science education. Both writing activities and concept mapping are reported as effective strategies for enhancing student learning of science. The purpose of this study was to examine the effect of a teaching model, named the DCI model, which integrates a Descriptive explanation writing activity, Concept mapping, and an Interpretive explanation writing activity, is introduced in a 4th grade science class to see if it would improve students' scientific explanations and understanding. A quasi-experimental design, including a non-randomized comparison group and a pre- and post-test design, was adopted for this study. An experimental group of 25 students were taught using the DCI teaching model, while a comparison group received a traditional lecture teaching. A rubric and content analysis was used to assess students' scientific explanations. The independent sample t test was used to measure difference in conceptual understanding between the two groups, before and after instruction. Then, the paired t test analysis was used to understand the promotion of the DCI teaching model. The results showed that students in the experimental group performed better than students in the comparison group, both in scientific concept understanding and explanation. Suggestions for using concept mapping and writing activities (the DCI teaching model) in science classes are provided in this study.

  2. Inhibition by antioxidants of nitric oxide synthase expression in murine macrophages: role of nuclear factor kappa B and interferon regulatory factor 1.

    PubMed Central

    Hecker, M.; Preiss, C.; Klemm, P.; Busse, R.

    1996-01-01

    1. In view of the potential deleterious effects of high amounts of nitric oxide (NO) produced by the inducible isoform of NO synthase (iNOS) in inflammation, the prevention of the expression of this enzyme represents an important therapeutic goal. In cytokine-stimulated cells, activation of nuclear factor kappa B (NF-kappa B) is crucial for the increase in iNOS gene expression. Since NF-kappa B activation appears to involve a redox-sensitive step, we have investigated whether three structurally unrelated antioxidants, 5,7-dihydroxyflavone (chrysin), 3,4-dichloroisocoumarin (DCI) and N-acetyl 5-hydroxytryptamine (N-acetylserotonin, NAS), affect iNOS expression in cultured RAW 264.7 monocyte/macrophages stimulated with bacterial lipopolysaccharide (LPS, 140 ng ml-1) and interferon-gamma (IFN gamma, 5 u ml-1). 2. During a 6 h incubation period neither LPS nor IFN gamma alone exerted a significant effect but when combined, caused a prominent increase in nitrite formation, iNOS mRNA and protein abundance. Co-incubation with chrysin (50 microM), DCI (50 microM) or NAS (1 mM) markedly attenuated this increase in iNOS gene expression. 3. DCI, but not chrysin or NAS, prevented the activation of NF-kappa B in cells exposed to LPS plus IFN gamma for 30 min. In contrast, all three antioxidants significantly blunted the DNA-binding activity of interferon regulatory factor 1 (IRF-1), which mediates the synergistic effect of IFN gamma on iNOS gene expression in cells treated for 2 h with LPS plus IFN gamma. 4. DCI thus appears to inhibit iNOS gene expression at the transcriptional level by preventing the activation of both NF-kappa B and IRF-1. The inhibitory effect of DCI on NF-kappa B activation, however, does not seem to be related to its antioxidative properties, since DCI, unlike chrysin or NAS, is a potent serine protease inhibitor which stabilizes the inactive NF-kappa B complex by protecting the inhibitory I kappa B-alpha subunit from proteolytic degradation. 5. The virtually identical inhibitory effect of chrysin, DCI and NAS on the activation of IRF-1 points to a redox-sensitive step in the activation of this transcription factor, which in contrast to NF-kappa B requires de novo protein synthesis. 6. Since iNOS gene expression in human cells and tissues usually requires the combination of several cytokines, antioxidants such as chrysin and NAS which do not interfere with the activation of NF-kappa B may be of therapeutic value for selectively inhibiting the enhanced expression of this enzyme in inflammation. Images Figure 4 Figure 6 Figure 7 PMID:8864559

  3. Incorporating High-Frequency Physiologic Data Using Computational Dictionary Learning Improves Prediction of Delayed Cerebral Ischemia Compared to Existing Methods.

    PubMed

    Megjhani, Murad; Terilli, Kalijah; Frey, Hans-Peter; Velazquez, Angela G; Doyle, Kevin William; Connolly, Edward Sander; Roh, David Jinou; Agarwal, Sachin; Claassen, Jan; Elhadad, Noemie; Park, Soojin

    2018-01-01

    Accurate prediction of delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH) can be critical for planning interventions to prevent poor neurological outcome. This paper presents a model using convolution dictionary learning to extract features from physiological data available from bedside monitors. We develop and validate a prediction model for DCI after SAH, demonstrating improved precision over standard methods alone. 488 consecutive SAH admissions from 2006 to 2014 to a tertiary care hospital were included. Models were trained on 80%, while 20% were set aside for validation testing. Modified Fisher Scale was considered the standard grading scale in clinical use; baseline features also analyzed included age, sex, Hunt-Hess, and Glasgow Coma Scales. An unsupervised approach using convolution dictionary learning was used to extract features from physiological time series (systolic blood pressure and diastolic blood pressure, heart rate, respiratory rate, and oxygen saturation). Classifiers (partial least squares and linear and kernel support vector machines) were trained on feature subsets of the derivation dataset. Models were applied to the validation dataset. The performances of the best classifiers on the validation dataset are reported by feature subset. Standard grading scale (mFS): AUC 0.54. Combined demographics and grading scales (baseline features): AUC 0.63. Kernel derived physiologic features: AUC 0.66. Combined baseline and physiologic features with redundant feature reduction: AUC 0.71 on derivation dataset and 0.78 on validation dataset. Current DCI prediction tools rely on admission imaging and are advantageously simple to employ. However, using an agnostic and computationally inexpensive learning approach for high-frequency physiologic time series data, we demonstrated that we could incorporate individual physiologic data to achieve higher classification accuracy.

  4. Persistent (patent) foramen ovale (PFO): implications for safe diving.

    PubMed

    Germonpré, Peter

    2015-06-01

    Diving medicine is a peculiar specialty. There are physicians and scientists from a wide variety of disciplines with an interest in diving and who all practice 'diving medicine': the study of the complex whole-body physiological changes and interactions upon immersion and emersion. To understand these, the science of physics and molecular gas and fluid movements comes into play. The ultimate goal of practicing diving medicine is to preserve the diver's health, both during and after the dive. Good medicine starts with prevention. For most divers, underwater excursions are not a professional necessity but a hobby; avoidance of risk is generally a much better option than risk mitigation or cure. However, prevention of diving illnesses seems to be even more difficult than treating those illnesses. The papers contained in this issue of DHM are a nice mix of various aspects of PFO that divers are interested in, all of them written by specialist doctors who are avid divers themselves. However, diving medicine should also take advantage of research from the "non-diving" medicine community, and PFO is a prime example. Cardiology and neurology have studied PFO for as long, or even longer than divers have been the subjects of PFO research, and with much greater numbers and resources. Unexplained stroke has been associated with PFO, as has severe migraine with aura. As the association seems to be strong, investigating the effect of PFO closure was a logical step. Devices have been developed and perfected, allowing now for a relatively low-risk procedure to 'solve the PFO problem'. However, as with many things in science, the results have not been as spectacular as hoped for: patients still get recurrences of stroke, still have migraine attacks. The risk-benefit ratio of PFO closure for these non-diving diseases is still debated. For diving, we now face a similar problem. Let there be no doubt that PFO is a pathway through which venous gas emboli (VGE) can arterialize, given sufficiently favourable circumstances (such as: a large quantity of VGE, size of the PFO, straining or provocation manoeuvres inducing increased right atrial pressure, delayed tissue desaturation so that seeding arterial gas emboli (AGE) grow instead of shrink, and there may be other, as yet unknown factors). There is no doubt that closing a PFO, either surgically or using a catheter-delivered device, can reduce the number of VGE becoming AGE. There is also no doubt that the procedure itself carries some health risks which are, at 1% or higher risk of serious complications, an order of magnitude greater than the risk for decompression illness (DCI) in recreational diving. Scientists seek the 'truth', but the truth about how much of a risk PFO represents for divers is not likely to be discovered nor universally accepted. First of all, the exact prevalence of PFO in divers is not known. As it has been pointed out in the recent literature, a contrast echocardiography (be it transthoracic or transoesophageal) or Doppler examination is only reliable if performed according to a strict protocol, taking into account the very many pitfalls yielding false negative results. The optimal procedure for injection of contrast medium was described several years ago, but has not received enough attention. Indeed, it is our and others' experience that many divers presenting with PFO-related DCI symptoms initially are declared "PFO-negative" by eminent, experienced cardiologists! Failing a prospective study, the risks of diving with a right-to left vascular shunt can only be expressed as an 'odds ratio', which is a less accurate measure than is 'relative risk'. The DAN Europe Carotid Doppler Study, started in 2001, is nearing completion and will provide more insight into the actual risks of DCI for recreational divers. The degree of DCI risk reduction from closing a PFO is thus not only dependent on successful closure but also (mostly?) on how the diver manages his/her dive and decompression in order to reduce the incidence of VGE. It has been convincingly shown that conservative dive profiles reduce DCI incidence even in divers with large PFOs, just as PFO closure does not protect completely from DCI if the dive profiles are aggressive. Prospective studies should not only focus on the reduction of DCI incidence after closure, but should take into account the costs and side effects of the procedure, as has been done in the cardiology and neurology studies. Imagine lung transplants becoming a routine operation, costly but with a high success rate; imagine also a longterm smoker suffering from a mild form of obstructive lung disease and exercise-limiting dyspnoea. Which of two options would you recommend: having a lung transplant and continue smoking as before, or quit smoking and observe a progressive improvement of pulmonary and cardiac pathology? As opposed to patients with thrombotic disease and migraine, divers can choose to reduce DCI risk. In fact, all it takes is acceptance that some types of diving carry too high a health risk - whether it is because of a PFO or another 'natural' factor. It would be unethical to promote PFO closure in divers solely on the basis of its efficacy of shunt reduction. Unfortunately, at least one device manufacturer has already done so in the past, citing various publications to specifically target recreational divers. Some technical diving organizations even have recommended preventive PFO closure in order to undertaking high-risk dive training. As scientists, we must not allow ourselves to be drawn into intuitive diver fears and beliefs. Nor should we let ourselves be blinded by the ease and seemingly low risk of the procedure. With proper and objective information provided by their diving medicine specialist, divers could make an informed decision, rather than focus on the simplistic idea that they need 'to get it fixed' in order to continue diving. A significant relationship between PFO and cerebral damage, in the absence of high-risk diving or DCI, has yet to be confirmed. Studying PFO-related DCI provides us with unique opportunities to learn more about the effect of gas bubbles in various tissues, including the central vascular bed and neurological tissue. It may also serve to educate divers that safe diving is something that needs to be learned, not something that can be implanted.

  5. Evaluation of Military Fuels Using a Ford 6.7L Powerstroke Diesel Engine

    DTIC Science & Technology

    2011-08-01

    natural steady state values during idle testing steps. Engine oil cooler plumbing was factory integrated to the engine water jacket, thus not...Innospec Fuel Specialties DCI-4A. Per QPL-25017, the minimum effective treat rate of DCI-4A required an additive concentration level of 9ppm in the...dynamometer was used to control engine speed and dissipate load. Engine load was manipulated through the actuation of the engine throttle pedal assembly

  6. [Emergency transcranial doppler ultrasound: predictive value for the development of symptomatic vasospasm in spontaneous subarachnoid hemorrhage in patients in good neurological condition].

    PubMed

    Muñoz-Sanchez, M A; Murillo-Cabezas, F; Egea-Guerrero, J J; Gascón-Castillo, M L; Cancela, P; Amaya-Villar, R; Rincón-Ferrari, M D; Flores-Cordero, J M; Cayuela, A; García-Alfaro, C

    2012-12-01

    To examine the predictive value of an early transcranial Doppler ultrasound (TCD) study performed in the emergency department in patients with spontaneous subarachoniod hemorrhage (SAH) in good neurological condition, in order to know which patients are at high risk of developing delayed cerebral ischemia (DCI). A descriptive observational study was carried out involving a period of 3 years. Critical Care and Emergency Department. The study consecutively included patients with SAH of grade I-III on the Hunt and Hess scale. DCI (decrease of 2 points in GCS or focal deficit), Mean Velocity (MV) of middle cerebral arteries (MCA), Lindegaard Index (IL). Sonographic vasospasm pattern (SVP) was considered if MCA-MV>120cm/sc and IL>3. The mean age of the 122 patients was 54.1±13.7 years; 57.3% were women. SVP was detected in 24 patients (19.7%), although high velocities patterns (HVP) were present in 38 patients (31.1%). DCI developed in 21 patients (MV183+/-49cm/sc), all with previous SVP. In this group MV increased 22+/-5cm/sc/day during the first 3 days. The group without HVP (84 patients/MV of 67+/-16.6cm/sc), compared with DCI group, showed differences in highest MV (p<0.001), and also ΔMV/day (8.30+/-4,5cm/sc Vs 22+/-5cm/sc) during the first 3 days (p=0.009). In our series, ROC analysis selected the best cut-off value for ΔMV/day as 21cm/sc (p<0.001). During the first 3 days, an increase of 21cm/s/24h in MCA-MV was associated with the development of symptomatic vasospasm. TCD is a useful tool for the early detection of patients at risk of DCI after SAH. Copyright © 2011 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  7. Chicago Classification normative metrics in a healthy Indian cohort for a 16-channel water-perfused high-resolution esophageal manometry system.

    PubMed

    Srinivas, M; Jain, M; Bawane, P; Jayanthi, V

    2018-06-01

    High-resolution esophageal manometry (HREM) interpretation by the Chicago Classification (CC) derives its normal values from western volunteers using solid-state catheters. There is no normative data for the 16-channel water-perfused HREM system commonly used in India. To determine normal values for a 16-channel water-perfused HREM catheter in supine posture using healthy volunteers and substitute these normal values (if different from CC values) in the CC v3.0 algorithm. After ethics approval and informed consent, 53 volunteers (31 men) with no gastrointestinal (GI) symptoms or medications affecting GI motility underwent HREM by standard protocol. Age, gender, body mass index (BMI), and manometry parameters analyzed using Trace 1.3.3 software were collected. The median, range, and 5, 10, 75, and 95 percentiles (where applicable) were obtained for all HREM metrics. Normal value percentiles were defined as 95th (integrated relaxation pressure [IRP]), 10th-100th (distal contractile integral [DCI]), and minimum (distal latency [DL]). The mean age was 30 years and the BMI was 24.2 kg m -2 . Compared to CC, our normal metrics were lower for IRP (13 mm Hg) and DCI (350-4500 mm Hg s cm). DCI >4500 and <70 (<5th percentile) were defined as hypercontractile and failed contraction, respectively. Abnormal DL (<4.5 s) and peristaltic break size (>5 cm) were similar to CC metrics. Applying these metrics, CC diagnoses changed in 15% (8/53) with downgrading of ineffective motility to fragmented peristalsis or normal, due to lower DCI cutoff used. This is the first report of normative data for the 16-channel water-perfused system in supine posture. It revealed lower IRP and DCI, necessitating modification of CC cutoffs for this system. © 2018 John Wiley & Sons Ltd.

  8. Decadal Climate Information Needs of Stakeholders for Decision Support in Water and Agriculture Production Sectors: A Case Study in the Missouri River Basin

    NASA Astrophysics Data System (ADS)

    Mehta, V. M.; Knutson, C.; Rosenberg, N.

    2012-12-01

    Many decadal climate prediction efforts have been initiated under the World Climate Research Programme's Coupled Model Intercomparison Project 5. There is considerable ongoing discussion about model deficiencies, initialization techniques, and data requirements, but not much attention is being given to decadal climate information (DCI) needs of stakeholders for decision support. We report the results of exploratory activities undertaken to assess DCI needs in water resources and agriculture sectors, using the Missouri River Basin (the Basin) as a case study. This assessment was achieved through discussions with 120 representative stakeholders. Stakeholders' awareness of decadal dry and wet spells and their societal impacts in the Basin is established; and stakeholders' DCI needs and potential barriers to their use of DCI are enumerated. We find that impacts, including economic impacts, of DCV on water and agricultural production in the Basin are distinctly identifiable and characterizable. Stakeholders have clear notions about their needs for DCI and have offered specific suggestions as to how these might be met. But, while stakeholders are eager to have climate information, including decadal climate outlooks (DCOs), there are many barriers to the use of such information. The first and foremost is that the credibility of DCOs is yet to be established. Secondly, the nature of institutional rules and regulations, laws, and legal precedents that pose obstacles to the use of DCOs must be better understood and means to modify these, where possible, must be sought. For the benefit of climate scientists, these and other stakeholder needs will also be articulated in this talk. We are engaged in a project to assess simulation and hindcast skills of DCV phenomena and their associations with hydro-meteorological variability in the Basin in the HadCM3, GFDL-CM2.1, NCAR CCSM4, and MIROC5 global coupled models participating in the WCRP's CMIP5 project. Results from this project will also be described and compared with stakeholder information needs.

  9. Burst of Energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-01

    The Discovery Center of Idaho (DCI) was the recipient of a grant from US DOE's Museum Science Education Program to build six permanent energy related exhibits to provide the public with hands-on experience with energy issues. Because of its volunteer support system, DC was able to build eleven exhibits. These exhibits are described and photographs are included. The signs used for the exhibits are reproduced as well as the materials used to advertise them to the public. Examples of DCI's newsletter are included that mention the new exhibits.

  10. Burst of energy

    NASA Astrophysics Data System (ADS)

    The Discovery Center of Idaho (DCI) was the recipient of a grant from US DOE's Museum Science Education Program to build six permanent energy related exhibits to provide the public with hands-on experience with energy issues. Because of its volunteer support system, DC was able to build eleven exhibits. These exhibits are described and photographs are included. The signs used for the exhibits are reproduced as well as the materials used to advertise them to the public. Examples of DCI's newsletter are included that mention the new exhibits.

  11. Patent Foramen Ovale as a Risk Factor for Altitude Decompression Illness

    DTIC Science & Technology

    2001-06-01

    TTE ). In 48 volunteers at DCIEM screened for the PRP studies with a TTE , 14 (29%) were found to have an echo-probable PFO. In 29 altitude-exposed...subjects who had a TTE , there were 5 echo-probable PFOs. None of these 5 subjects experienced DCI. Two of these subjects had a high bubble load with grade...16% incidence (by TTE ) of PFO amongst 24 cases of Type II altitude DCI using trans- esophogeal echocardiography (TEE), suggesting that there was no

  12. Burst of Energy. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-12-01

    The Discovery Center of Idaho (DCI) was the recipient of a grant from US DOE`s Museum Science Education Program to build six permanent energy related exhibits to provide the public with hands-on experience with energy issues. Because of its volunteer support system, DC was able to build eleven exhibits. These exhibits are described and photographs are included. The signs used for the exhibits are reproduced as well as the materials used to advertise them to the public. Examples of DCI`s newsletter are included that mention the new exhibits.

  13. Jackhammer esophagus: Observations on a European cohort.

    PubMed

    Herregods, T V K; Smout, A J P M; Ooi, J L S; Sifrim, D; Bredenoord, A J

    2017-04-01

    With the advent of high-resolution manometry (HRM), a new diagnosis, jackhammer esophagus, was introduced. Little is known about this rare condition, and the relationship between symptoms and hypercontractility is not always straightforward. The aim of our study was to describe a large cohort of patients with jackhammer esophagus and to investigate whether manometric findings are associated with the presence of symptoms. All patients from 06, 2014 until 12, 2015 seen at two tertiary centers with at least one hypercontractile swallow (distal contractile integral [DCI] >8000 mm Hg/s/cm) on HRM were analyzed. Patients with ≥20% premature swallows, or patients with another diagnosis explaining their symptoms were excluded. Of the 34 patients identified with jackhammer esophagus, most suffered from dysphagia (67.6%) and/or chest pain (47.1%). The symptom chest pain was not associated with any of the manometric findings, whereas dysphagia was associated with the DCI of the hypercontractile swallows and with intrabolus pressure. In addition, all patients who had an isolated DCI of the lower esophageal sphincter (LES) zone >2000 mm Hg/s/cm had dysphagia. The differences in HRM and clinical characteristics between subgroups based on the contraction type (single- or multi-peaked) or based on meeting criteria of the Chicago Classification v3.0 and v2.0 were limited. The symptom dysphagia is accompanied with strong contractions of the LES, signs of a possible outflow obstruction, and a very high DCI. The presence of a multipeaked contraction seems to be of limited relevance, and caution is warranted in labeling patients with one hypercontractile swallow as normal. © 2016 John Wiley & Sons Ltd.

  14. Low concentration of sodium bicarbonate improves the bioactive compound levels and antioxidant and α-glucosidase inhibitory activities of tartary buckwheat sprouts.

    PubMed

    Qin, Peiyou; Wei, Aichun; Zhao, Degang; Yao, Yang; Yang, Xiushi; Dun, Baoqing; Ren, Guixing

    2017-06-01

    This study aimed to investigate the effects of different concentrations of sodium bicarbonate (NaHCO 3 ) on the accumulation of flavonoids, total phenolics and d-chiro-inositol (DCI), as well as the antioxidant and α-glucosidase inhibitory activities, in tartary buckwheat sprouts. Treatment with low concentrations of NaHCO 3 (0.05, 0.1, and 0.2%) resulted in an increase in flavonoids, total phenolic compounds and DCI concentrations, and improved DPPH radical-scavenging and α-glucosidase inhibition activities compared with the control (0%). The highest levels of total flavonoids (26.69mg/g DW), individual flavonoids (rutin, isoquercitrin, quercetin, and kaempferol), total phenolic compounds (29.31mg/g DW), DCI (12.56mg/g DW), as well as antioxidant and α-glucosidase inhibition activities, were observed in tartary buckwheat sprouts treated with 0.05% NaHCO 3 for 96h. These results indicated that appropriate treatment with NaHCO 3 could improve the healthy benefits of tartary buckwheat sprouts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Thermomechanical Fatigue of Ductile Cast Iron and Its Life Prediction

    NASA Astrophysics Data System (ADS)

    Wu, Xijia; Quan, Guangchun; MacNeil, Ryan; Zhang, Zhong; Liu, Xiaoyang; Sloss, Clayton

    2015-06-01

    Thermomechanical fatigue (TMF) behaviors of ductile cast iron (DCI) were investigated under out-of-phase (OP), in-phase (IP), and constrained strain-control conditions with temperature hold in various temperature ranges: 573 K to 1073 K, 723 K to 1073 K, and 433 K to 873 K (300 °C to 800 °C, 450 °C to 800 °C, and 160 °C to 600 °C). The integrated creep-fatigue theory (ICFT) model was incorporated into the finite element method to simulate the hysteresis behavior and predict the TMF life of DCI under those test conditions. With the consideration of four deformation/damage mechanisms: (i) plasticity-induced fatigue, (ii) intergranular embrittlement, (iii) creep, and (iv) oxidation, as revealed from the previous study on low cycle fatigue of the material, the model delineates the contributions of these physical mechanisms in the asymmetrical hysteresis behavior and the damage accumulation process leading to final TMF failure. This study shows that the ICFT model can simulate the stress-strain response and life of DCI under complex TMF loading profiles (OP and IP, and constrained with temperature hold).

  16. Decreased clinical pregnancy and live birth rates after short interval from delivery to subsequent assisted reproductive treatment cycle.

    PubMed

    Quinn, Molly M; Rosen, Mitchell P; Allen, Isabel Elaine; Huddleston, Heather G; Cedars, Marcelle I; Fujimoto, Victor Y

    2018-06-15

    Does the interval from delivery to initiation of a subsequent ART treatment cycle impact clinical pregnancy or live birth rates? An interval from delivery to treatment start of <6 months or ≥24 months is associated with decreased likelihood of clinical pregnancy and live birth. Short interpregnancy intervals are associated with poor obstetric outcomes in the naturally conceiving population prompting birth spacing recommendations of 18-24 months from international organizations. Deferring a subsequent pregnancy attempt means a woman will age in the interval with an attendant decline in her fertility. Retrospective analysis of the Society for Assisted Reproductive Technology Clinical Outcome Reporting System (SARTCORS) cohort containing 61 686 ART cycles from 2004 to 2013. The delivery-to-cycle interval (DCI) was calculated for patients from SARTCORS with a history of live birth from ART who returned to the same clinic for a first subsequent treatment cycle. Generalized linear models were fit to determine the risk of clinical pregnancy and live birth by DCI with subsequent adjustment for factors associated with outcomes of interest. Predicted probabilities of clinical pregnancy and live birth were generated from each model. A DCI of <6 months was associated with a 5.6% reduction in probability of clinical pregnancy (40.1 ± 1.9 versus 45.7 ± 0.6%, P = 0.009) and 6.8% reduction in live birth (31.6 ± 1.7 versus 38.4 ± 0.6%, P = 0.001) per cycle start compared to a DCI of 12 to <18 months. A DCI of ≥24 months was associated with a 5.1% reduction in probability of clinical pregnancy (40.6 ± 0.5 versus 45.7 ± 0.6%, P < 0.001) and 5.7% reduction in live birth (32.7 ± 0.5 versus 38.4 ± 0.6%, P < 0.001) compared to 12 to <18 months. The SART database is reliant upon self-report of many variables of interest including live birth. It remains unclear whether poorer outcomes are a result of residual confounding from factors inherent to the population with a very short or long DCI or the interval itself. Birth spacing recommendations for naturally conceiving populations may not be generally applicable to patients with a history of infertility. Patients planning ART treatment should wait a minimum of 6 months, but not more than 24 months, from a live birth for optimization of clinical pregnancy and live birth rates. National Center for Advancing Translational Sciences, National Institutes of Health, UCSF-CTSI Grant number UL1TR001872. The authors have no competing interests.

  17. Assessment of the Impact of a New Guanidine Suppressor In NGS on F/H Laboratory Analyses For DWPF and Saltstone MCU Transfers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.

    2013-04-29

    Implementation of the Next Generation Solvent (NGS) in the Modular Caustic-Side Solvent Extraction Unit (MCU) will now proceed with a new suppressor compound, 1,2,3-tris(3,7-dimethyloctyl)guanidine (TiDG), replacing the originally planned suppressor for NGS, 1,3-dicyclohexyl-2-(11-methyldodecyl) guanidine (DCiTG). The Savannah River National Laboratory (SRNL) was tasked with evaluating the potential impact to F/H Laboratory analyses supporting the Defense Waste Processing Facility (DWPF) Waste Acceptance Criteria (WAC) used to qualify transfers of MCU Strip Effluent (SE) into the facility and the Saltstone WAC used to qualify transfers of Tank 50 containing Decontaminated Salt Solution (DSS) from MCU into Saltstone. This assigned scope is coveredmore » by a Task Technical and Quality Assurance Plan (TTQAP). Previous impact evaluations were conducted when the DCiTG suppressor was planned for NGS and concluded that there was no impact to either the determination of MCU SE pH nor the analysis of Isopar® L carryover in the MCU SE and DSS streams. SRNL reported on this series of cross-check studies between the SRNL and F/H Laboratories. The change in suppressor from DCiTG to TiDG in the NGS should not impact the measurement of Isopar® L or pH in SE or DSS necessary to satisfy DWPF and Saltstone WAC (Tank 50) criteria, respectively. A statistical study of the low bias observed in Isopar® L measurements in both SRNL and F/H Laboratories may be necessary now that the final NGS composition is fixed in order to quantify the low bias so that a proper correction can be applied to measurements critical to the DWPF and Saltstone WACs. Depending upon the final DWPF WAC requirement put in place for SE pH, it could become necessary to implement an alternative ICP-AES measurement of boron. The current blended solvent system testing in SRNL should address any impacts to Isopar® L carryover into either the DSS or the SE. It is recommended that SRNL monitor the current blended solvent work underway with simulants in SRNL as well as any DWPF CPC testing done with the new SE stream to ascertain whether any need develops that could result in modification of any currently planned F/H Laboratory testing protocols.« less

  18. Fragmentation alters stream fish community structure in dendritic ecological networks.

    PubMed

    Perkin, Joshuah S; Gido, Keith B

    2012-12-01

    Effects of fragmentation on the ecology of organisms occupying dendritic ecological networks (DENs) have recently been described through both conceptual and mathematical models, but few hypotheses have been tested in complex, real-world ecosystems. Stream fishes provide a model system for assessing effects of fragmentation on the structure of communities occurring within DENs, including how fragmentation alters metacommunity dynamics and biodiversity. A recently developed habitat-availability measure, the "dendritic connectivity index" (DCI), allows for assigning quantitative measures of connectivity in DENs regardless of network extent or complexity, and might be used to predict fish community response to fragmentation. We characterized stream fish community structure in 12 DENs in the Great Plains, USA, during periods of dynamic (summer) and muted (fall) discharge regimes to test the DCI as a predictive model of fish community response to fragmentation imposed by road crossings. Results indicated that fish communities in stream segments isolated by road crossings had reduced species richness (alpha diversity) relative to communities that maintained connectivity with the surrounding DEN during summer and fall. Furthermore, isolated communities had greater dissimilarity (beta diversity) to downstream sites notisolated by road crossings during summer and fall. Finally, dissimilarity among communities within DENs decreased as a function of increased habitat connectivity (measured using the DCI) for summer and fall, suggesting that communities within highly connected DENs tend to be more homogeneous. Our results indicate that the DCI is sensitive to community effects of fragmentation in riverscapes and might be used by managers to predict ecological responses to changes in habitat connectivity. Moreover, our findings illustrate that relating structural connectivity of riverscapes to functional connectivity among communities might aid in maintaining metacommunity dynamics and biodiversity in complex dendritic ecosystems.

  19. Effects of phosphate addition on biofilm bacterial communities and water quality in annular reactors equipped with stainless steel and ductile cast iron pipes.

    PubMed

    Jang, Hyun-Jung; Choi, Young-June; Ro, Hee-Myong; Ka, Jong-Ok

    2012-02-01

    The impact of orthophosphate addition on biofilm formation and water quality was studied in corrosion-resistant stainless steel (STS) pipe and corrosion-susceptible ductile cast iron (DCI) pipe using cultivation and culture-independent approaches. Sample coupons of DCI pipe and STS pipe were installed in annular reactors, which were operated for 9 months under hydraulic conditions similar to a domestic plumbing system. Addition of 5 mg/L of phosphate to the plumbing systems, under low residual chlorine conditions, promoted a more significant growth of biofilm and led to a greater rate reduction of disinfection by-products in DCI pipe than in STS pipe. While the level of THMs (trihalomethanes) increased under conditions of low biofilm concentration, the levels of HAAs (halo acetic acids) and CH (chloral hydrate) decreased in all cases in proportion to the amount of biofilm. It was also observed that chloroform, the main species of THM, was not readily decomposed biologically and decomposition was not proportional to the biofilm concentration; however, it was easily biodegraded after the addition of phosphate. Analysis of the 16S rDNA sequences of 102 biofilm isolates revealed that Proteobacteria (50%) was the most frequently detected phylum, followed by Firmicutes (10%) and Actinobacteria (2%), with 37% of the bacteria unclassified. Bradyrhizobium was the dominant genus on corroded DCI pipe, while Sphingomonas was predominant on non-corroded STS pipe. Methylobacterium and Afipia were detected only in the reactor without added phosphate. PCR-DGGE analysis showed that the diversity of species in biofilm tended to increase when phosphate was added regardless of the pipe material, indicating that phosphate addition upset the biological stability in the plumbing systems.

  20. Multiple Rapid Swallow Responses During Esophageal High-Resolution Manometry Reflect Esophageal Body Peristaltic Reserve

    PubMed Central

    Shaker, Anisa; Stoikes, Nathaniel; Drapekin, Jesse; Kushnir, Vladimir; Brunt, L. Michael; Gyawali, C. Prakash

    2014-01-01

    OBJECTIVES Dysphagia may develop following antireflux surgery as a consequence of poor esophageal peristaltic reserve. We hypothesized that suboptimal contraction response following multiple rapid swallows (MRS) could be associated with chronic transit symptoms following antireflux surgery. METHODS Wet swallow and MRS responses on esophageal high-resolution manometry (HRM) were characterized collectively in the esophageal body (distal contractile integral (DCI)), and individually in each smooth muscle contraction segment (S2 and S3 amplitudes) in 63 patients undergoing antireflux surgery and in 18 healthy controls. Dysphagia was assessed using symptom questionnaires. The MRS/wet swallow ratios were calculated for S2 and S3 peak amplitudes and DCI. MRS responses were compared in patients with and without late postoperative dysphagia following antireflux surgery. RESULTS Augmentation of smooth muscle contraction (MRS/wet swallow ratios > 1.0) as measured collectively by DCI was seen in only 11.1% with late postoperative dysphagia, compared with 63.6% in those with no dysphagia and 78.1% in controls (P≤0.02 for each comparison). Similar results were seen with S3 but not S2 peak amplitude ratios. Receiver operating characteristics identified a DCI MRS/wet swallow ratio threshold of 0.85 in segregating patients with late postoperative dysphagia from those with no postoperative dysphagia with a sensitivity of 0.67 and specificity of 0.64. CONCLUSIONS Lack of augmentation of smooth muscle contraction following MRS is associated with late postoperative dysphagia following antireflux surgery, suggesting that MRS responses could assess esophageal smooth muscle peristaltic reserve. Further research is warranted to determine if antireflux surgery needs to be tailored to the MRS response. PMID:24019081

  1. Results from the International Consensus Conference on Myo-inositol and d-chiro-inositol in Obstetrics and Gynecology: the link between metabolic syndrome and PCOS.

    PubMed

    Facchinetti, Fabio; Bizzarri, Mariano; Benvenga, Salvatore; D'Anna, Rosario; Lanzone, Antonio; Soulage, Christophe; Di Renzo, Gian Carlo; Hod, Moshe; Cavalli, Pietro; Chiu, Tony T; Kamenov, Zdravko A; Bevilacqua, Arturo; Carlomagno, Gianfranco; Gerli, Sandro; Oliva, Mario Montanino; Devroey, Paul

    2015-12-01

    In recent years, interest has been focused to the study of the two major inositol stereoisomers: myo-inositol (MI) and d-chiro-inositol (DCI), because of their involvement, as second messengers of insulin, in several insulin-dependent processes, such as metabolic syndrome and polycystic ovary syndrome. Although these molecules have different functions, very often their roles have been confused, while the meaning of several observations still needs to be interpreted under a more rigorous physiological framework. With the aim of clarifying this issue, the 2013 International Consensus Conference on MI and DCI in Obstetrics and Gynecology identified opinion leaders in all fields related to this area of research. They examined seminal experimental papers and randomized clinical trials reporting the role and the use of inositol(s) in clinical practice. The main topics were the relation between inositol(s) and metabolic syndrome, polycystic ovary syndrome (with a focus on both metabolic and reproductive aspects), congenital anomalies, gestational diabetes. Clinical trials demonstrated that inositol(s) supplementation could fruitfully affect different pathophysiological aspects of disorders pertaining Obstetrics and Gynecology. The treatment of PCOS women as well as the prevention of GDM seem those clinical conditions which take more advantages from MI supplementation, when used at a dose of 2g twice/day. The clinical experience with MI is largely superior to the one with DCI. However, the existence of tissue-specific ratios, namely in the ovary, has prompted researchers to recently develop a treatment based on both molecules in the proportion of 40 (MI) to 1 (DCI). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Domestication of Lambda Phage Genes into a Putative Third Type of Replicative Helicase Matchmaker

    PubMed Central

    Brézellec, Pierre; Petit, Marie-Agnès; Pasek, Sophie; Vallet-Gely, Isabelle; Possoz, Christophe

    2017-01-01

    Abstract At the onset of the initiation of chromosome replication, bacterial replicative helicases are recruited and loaded on the DnaA-oriC nucleoprotein platform, assisted by proteins like DnaC/DnaI or DciA. Two orders of bacteria appear, however, to lack either of these factors, raising the question of the essentiality of these factors in bacteria. Through a phylogenomic approach, we identified a pair of genes that could have substituted for dciA. The two domesticated genes are specific of the dnaC/dnaI- and dciA-lacking organisms and apparently domesticated from lambdoid phage genes. They derive from λO and λP and were renamed dopC and dopE, respectively. DopE is expected to bring the replicative helicase to the bacterial origin of replication, while DopC might assist DopE in this function. The confirmation of the implication of DopCE in the handling of the replicative helicase at the onset of replication in these organisms would generalize to all bacteria and therefore to all living organisms the need for specific factors dedicated to this function. PMID:28854626

  3. d-chiro-Inositol and alpha lipoic acid treatment of metabolic and menses disorders in women with PCOS.

    PubMed

    Cianci, Antonio; Panella, Marco; Fichera, Michele; Falduzzi, Cristina; Bartolo, Manuela; Caruso, Salvatore

    2015-06-01

    To evaluate the effects of the combination of d-chiro-inositol (DCI) and alpha lipoic acid on menses and metabolic disorders in women with polycystic ovary syndrome (PCOS). Forty-six women (26 study group subjects and 20 controls) of reproductive age with PCOS according to Rotterdam criteria were enrolled in this prospective study. Fasting serum samples were collected from each woman. Homeostasis model of insulin resistance, insulin levels, lipid profile, frequency of menstrual cycles, number of ovarian peripheral cysts and BMI of both groups were investigated at baseline and after 180 days. Clinical and metabolic aspects of women on DCI and lipoic acid treatment underwent improvement (p < 0.5) with respect to the control group. Regarding lipid profile, no statistically difference was observed in total cholesterol and triglycerides levels in both groups at follow-up with respect the baseline values (p = NS). DCI and alpha lipoic acid treatment has been thought because it plays an essential role in mitochondrial specific pathways that generate energy from glucose and its potent effect as antioxidant. The association might have a strong impact on metabolic profile even with a short-term treatment. Further investigations are needed to evaluate other effects on reproductive physiology of women with PCOS.

  4. Quantitative trait loci controlling leaf appearance and curd initiation of cauliflower in relation to temperature.

    PubMed

    Hasan, Yaser; Briggs, William; Matschegewski, Claudia; Ordon, Frank; Stützel, Hartmut; Zetzsche, Holger; Groen, Simon; Uptmoor, Ralf

    2016-07-01

    QTL regions on chromosomes C06 and C09 are involved in temperature dependent time to curd induction in cauliflower. Temperature is the main environmental factor influencing curding time of cauliflower (Brassica oleracea var. botrytis). Temperatures above 20-22 °C inhibit development towards curding even in many summer cultivars. To identify quantitative trait loci (QTL) controlling curding time and its related traits in a wide range of different temperature regimes from 12 to 27 °C, a doubled haploid (DH) mapping population segregating for curding time was developed and days to curd initiation (DCI), leaf appearance rate (LAR), and final leaf number (FLN) were measured. The population was genotyped with 176 single nucleotide polymorphism (SNP) markers. Composite interval mapping (CIM) revealed repeatedly detected QTL for DCI on C06 and C09. The estimated additive effect increased at high temperatures. Significant QTL × environment interactions (Q × E) for FLN and DCI on C06 and C09 suggest that these hotspot regions have major influences on temperature mediated curd induction. 25 % of the DH lines did not induce curds at temperatures higher than 22 °C. Applying a binary model revealed a QTL with LOD >15 on C06. Nearly all lines carrying the allele of the reliable early maturing parental line (PL) on that locus induced curds at high temperatures while only half of the DH lines carrying the allele of the unreliable PL reached the generative phase during the experiment. Large variation in LAR was observed. QTL for LAR were detected repeatedly in several environments on C01, C04 and C06. Negative correlations between LAR and DCI and QTL co-localizations on C04 and C06 suggest that LAR has also effects on development towards curd induction.

  5. Haptoglobin phenotype predicts cerebral vasospasm and clinical deterioration after aneurysmal subarachnoid hemorrhage.

    PubMed

    Ohnishi, Hiroyuki; Iihara, Koji; Kaku, Yasuyuki; Yamauchi, Keita; Fukuda, Kenji; Nishimura, Kunihiro; Nakai, Michikazu; Satow, Tetsu; Nakajima, Norio; Ikegawa, Masaya

    2013-05-01

    Vasospasm (VS) and delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH) are thought to greatly affect prognosis. Haptoglobin (Hp) is a hemoglobin-binding protein expressed by a genetic polymorphism (1-1, 2-1, and 2-2). Our objects were to investigate whether the Hp phenotype could predict the incidence of cerebral infarction, favorable outcome, clinical deterioration by DCI, and angiographical VS after aneurysmal SAH. Ninety-five consecutive patients who underwent clipping or coil embolization were studied. Favorable functional outcome was defined as a modified Rankin Scale score of 0-2 at 3 months. Angiographical VS was diagnosed based on cerebral angiography findings performed between days 7 and 10 after SAH. The Hp 2-2 group had a significantly greater risk of angiographical VS than that of Hp 2-1 and 1-1 groups combined on univariate (odds ratio [OR]: 3.60, confidence interval [CI]: 1.49-8.67, P = .003) and multivariate logistic regression analyses after being adjusted for age, sex, Fisher groups, and other risk factors (OR: 3.75, CI: 1.54-9.16, P = .004). The Hp 2-2 group also showed the tendency of a greater risk of clinical deterioration by DCI with marginal significance on univariate and age- and sex-adjusted analyses (univariate OR: 2.46, CI: .90-6.74, P = .080; age- and sex-adjusted OR: 2.46, CI: .89-6.82, P = .080) but not after being adjusted for other multiple risk factors. The Hp 2-2 group was not associated with the favorable 3-month outcome and cerebral infarction (univariate: P = .867, P = .209; multivariate: P = .905, P = .292). The Hp phenotype seems to be associated with a higher rate of angiographical VS and clinical deterioration by DCI but does not affect the incidence of cerebral infarction and favorable outcome. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  6. Time Courses of Inflammatory Markers after Aneurysmal Subarachnoid Hemorrhage and Their Possible Relevance for Future Studies.

    PubMed

    Höllig, Anke; Stoffel-Wagner, Birgit; Clusmann, Hans; Veldeman, Michael; Schubert, Gerrit A; Coburn, Mark

    2017-01-01

    Aneurysmal subarachnoid hemorrhage triggers an intense inflammatory response, which is suspected to increase the risk for secondary complications such as delayed cerebral ischemia (DCI). However, to date, the monitoring of the inflammatory response to detect secondary complications such as DCI has not become part of the clinical routine diagnostic. Here, we aim to illustrate the time courses of inflammatory parameters after aneurysmal subarachnoid hemorrhage (aSAH) and discuss the problems of inflammatory parameters as biomarkers but also their possible relevance for deeper understanding of the pathophysiology after aSAH and sophisticated planning of future studies. In this prospective cohort study, 109 patients with aSAH were initially included, n  = 28 patients had to be excluded. Serum and-if possible-cerebral spinal fluid samples ( n  = 48) were retrieved at days 1, 4, 7, 10, and 14 after aSAH. Samples were analyzed for leukocyte count and C-reactive protein (CRP) (serum samples only) as well as matrix metallopeptidase 9 (MMP9), intercellular adhesion molecule 1 (ICAM1), and leukemia inhibitory factor (LIF) [both serum and cerebrospinal fluid (CSF) samples]. Time courses of the inflammatory parameters were displayed and related to the occurrence of DCI. We illustrate the time courses of leukocyte count, CRP, MMP9, ICAM1, and LIF in patients' serum samples from the first until the 14th day after aSAH. Time courses of MMP9, ICAM1, and LIF in CSF samples are demonstrated. Furthermore, no significant difference was shown relating the time courses to the occurrence of DCI. We estimate that the wide range of the measured values hampers their interpretation and usage as a biomarker. However, understanding the inflammatory response after aSAH and generating a multicenter database may facilitate further studies: realistic sample size calculations on the basis of a multicenter database will increase the quality and clinical relevance of the acquired results.

  7. In-water recompression.

    PubMed

    Doolette, David J; Mitchell, Simon J

    2018-06-30

    Divers suspected of suffering decompression illness (DCI) in locations remote from a recompression chamber are sometimes treated with in-water recompression (IWR). There are no data that establish the benefits of IWR compared to conventional first aid with surface oxygen and transport to the nearest chamber. However, the theoretical benefit of IWR is that it can be initiated with a very short delay to recompression after onset of manifestations of DCI. Retrospective analyses of the effect on outcome of increasing delay generally do not capture this very short delay achievable with IWR. However, in military training and experimental diving, delay to recompression is typically less than two hours and more than 90% of cases have complete resolution of manifestations during the first treatment, often within minutes of recompression. A major risk of IWR is that of an oxygen convulsion resulting in drowning. As a result, typical IWR oxygen-breathing protocols use shallower maximum depths (9 metres' sea water (msw), 191 kPa) and are shorter (1-3 hours) than standard recompression protocols for the initial treatment of DCI (e.g., US Navy Treatment Tables 5 and 6). There has been no experimentation with initial treatment of DCI at pressures less than 285 kPa since the original development of these treatment tables, when no differences in outcomes were seen between maximum pressures of 203 kPa (10 msw) and 285 kPa (18 msw) or deeper. These data and case series suggest that recompression treatment comprising pressures and durations similar to IWR protocols can be effective. The risk of IWR is not justified for treatment of mild symptoms likely to resolve spontaneously or for divers so functionally compromised that they would not be safe in the water. However, IWR conducted by properly trained and equipped divers may be justified for manifestations that are life or limb threatening where timely recompression is unavailable. Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

  8. Stabilization with the Dynamic Cervical Implant: a novel treatment approach following cervical discectomy and decompression.

    PubMed

    Matgé, Guy; Berthold, Christophe; Gunness, Vimal Raj Nitish; Hana, Ardian; Hertel, Frank

    2015-03-01

    Although cervical total disc replacement (TDR) has shown equivalence or superiority to anterior cervical discectomy and fusion (ACDF), potential problems include nonphysiological motion (hypermobility), accelerated degeneration of the facet joints, particulate wear, and compromise of the mechanical integrity of the endplate during device fixation. Dynamic cervical stabilization is a novel motion-preserving concept that facilitates controlled, limited flexion and extension, but prevents axial rotation and lateral bending, thereby reducing motion across the facet joints. Shock absorption of the Dynamic Cervical Implant (DCI) device is intended to protect adjacent levels from accelerated degeneration. The authors conducted a prospective evaluation of 53 consecutive patients who underwent DCI stabilization for the treatment of 1-level (n = 42), 2-level (n = 9), and 3-level (n = 2) cervical disc disease with radiculopathy or myelopathy. Forty-seven patients (89%) completed all clinical and radiographic outcomes at a minimum of 24 months. Clinical outcomes consisted of Neck Disability Index (NDI) and visual analog scale (VAS) scores, neurological function at baseline and at latest follow-up, as well as patient satisfaction. Flexion-extension radiography was evaluated for device motion, implant migration, subsidence, and heterotopic ossification. Cervical sagittal alignment (Cobb angle), functional spinal unit (FSU) angle, and range of motion (ROM) at index and adjacent levels were evaluated with WEB 1000 software. The NDI score, VAS neck and arm pain scores, and neurological deficits were significantly reduced at each postoperative time point compared with baseline (p < 0.0001). At 24 months postoperatively, 91% of patients were very satisfied and 9% somewhat satisfied, while 89% would definitely and 11% would probably elect to have the same surgery again. In 47 patients with 58 operated levels, the radiographic assessment showed good motion (5°-12°) of the device in 57%, reduced motion (2°-5°) in 34.5%, and little motion (0-2°) in 8.5%. The Cobb and FSU angles improved, showing a clear tendency for lordosis with the DCI. Motion greater than 2° of the treated segment could be preserved in 91.5%, while 8.5% had a near segmental fusion. Mean ROM at index levels demonstrated satisfying motion preservation with DCI. Mean ROM at upper and lower adjacent levels showed maintenance of adjacent-level kinematics. Heterotopic ossification, including 20% minor and 15% major, had no direct impact on clinical results. There were 2 endplate subsidences detected with an increased segmental lordosis. One asymptomatic anterior device migration required reoperation. Three patients underwent a secondary surgery in another segment during follow-up, twice for a new disc herniation and once for an adjacent degeneration. There was no posterior migration and no device breakage. Preliminary results indicate that the DCI implanted using a proper surgical technique is safe and facilitates excellent clinical outcomes, maintains index-and adjacent-level ROM in the majority of cases, improves sagittal alignment, and may be suitable for patients with facet arthrosis who would otherwise not be candidates for cervical TDR. Shock absorption together with maintained motion in the DCI may protect adjacent levels from early degeneration in longer follow-up.

  9. Evolution of deceased organ donation activity vs. efficiency over a 15 year period: an international comparison.

    PubMed

    Weiss, Julius; Elmer, Andreas; Mahíllo, Beatriz; Domínguez-Gil, Beatriz; Avsec, Danica; Costa, Alessandro Nanni; Haase-Kromwijk, Bernadette J J M; Laouabdia, Karim; Immer, Franz F

    2018-04-19

    The donation rate (DR) per million population is not ideal for an efficiency comparison of national deceased organ donation programs. The DR does not account for variabilities in the potential for deceased donation which mainly depends on fatalities from causes leading to brain death. In this study, the donation activity was put into relation to the mortality from selected causes. Based on that metric, this study assesses the efficiency of different donation programs. This is a retrospective analysis of 2001-2015 deceased organ donation and mortality registry data. Included are 27 Council of Europe countries, as well as the USA. A donor conversion index (DCI) was calculated for assessing donation program efficiency over time and in international comparisons. According to the DCI and of the countries included in the study, Spain, France, and the USA had the most efficient donation programs in 2015. Even though mortality from the selected causes decreased in most countries during the study period, differences in international comparisons persist. This indicates that the potential for deceased organ donation and its conversion into actual donation is far from being similar internationally. Compared with the DR, the DCI takes into account the potential for deceased organ donation, and therefore is a more accurate metric of performance. National donation programs could optimize performance by identifying the areas where most potential is lost, and by implementing measures to tackle these issues.

  10. The Influence of Water Conservancy Projects on River Network Connectivity, A Case of Luanhe River Basin

    NASA Astrophysics Data System (ADS)

    Li, Z.; Li, C.

    2017-12-01

    Connectivity is one of the most important characteristics of a river, which is derived from the natural water cycle and determine the renewability of river water. The water conservancy project can change the connectivity of natural river networks, and directly threaten the health and stability of the river ecosystem. Based on the method of Dendritic Connectivity Index (DCI), the impacts from sluices and dams on the connectivity of river network are deeply discussed herein. DCI quantitatively evaluate the connectivity of river networks based on the number of water conservancy facilities, the connectivity of fish and geographical location. The results show that the number of water conservancy facilities and their location in the river basin have a great influence on the connectivity of the river network. With the increase of the number of sluices and dams, DCI is decreasing gradually, but its decreasing range is becoming smaller and smaller. The dam located in the middle of the river network cuts the upper and lower parts of the whole river network, and destroys the connectivity of the river network more seriously. Therefore, this method can be widely applied to the comparison of different alternatives during planning of river basins and then provide a reference for the site selection and design of the water conservancy project and facility concerned.

  11. Diving Medicine: Frequently Asked Questions

    MedlinePlus

    ... after diving In-Water Recompression Inter-Island Flights Massage & Diving Return to Diving After DCI Subcutaneous Emphysema ... Donating Blood Flu-like Symptoms Following a Dive Foot Pain After Diving Fin Foot Frontal Headaches Hand & ...

  12. Situation Awareness of Onboard System Autonomy

    NASA Technical Reports Server (NTRS)

    Schreckenghost, Debra; Thronesbery, Carroll; Hudson, Mary Beth

    2005-01-01

    We have developed intelligent agent software for onboard system autonomy. Our approach is to provide control agents that automate crew and vehicle systems, and operations assistants that aid humans in working with these autonomous systems. We use the 3 Tier control architecture to develop the control agent software that automates system reconfiguration and routine fault management. We use the Distributed Collaboration and Interaction (DCI) System to develop the operations assistants that provide human services, including situation summarization, event notification, activity management, and support for manual commanding of autonomous system. In this paper we describe how the operations assistants aid situation awareness of the autonomous control agents. We also describe our evaluation of the DCI System to support control engineers during a ground test at Johnson Space Center (JSC) of the Post Processing System (PPS) for regenerative water recovery.

  13. Astrobiology Learning Progressions: Linking Astrobiology Concepts with the 3D Learning Paradigm of NGSS

    NASA Astrophysics Data System (ADS)

    Scalice, D.; Davis, H. B.; Leach, D.; Chambers, N.

    2016-12-01

    The Next Generation Science Standards (NGSS) introduce a Framework for teaching and learning with three interconnected "dimensions:" Disciplinary Core Ideas (DCI's), Cross-cutting Concepts (CCC's), and Science and Engineering Practices (SEP's). This "3D" Framework outlines progressions of learning from K-12 based on the DCI's, detailing which parts of a concept should be taught at each grade band. We used these discipline-based progressions to synthesize interdisciplinary progressions for core concepts in astrobiology, such as the origins of life, what makes a world habitable, biosignatures, and searching for life on other worlds. The final product is an organizing tool for lesson plans, learning media, and other educational materials in astrobiology, as well as a fundamental resource in astrobiology education that serves both educators and scientists as they plan and carry out their programs for learners.

  14. Intrathecal application of the nimodipine slow-release microparticle system eg-1962 for prevention of delayed cerebral ischemia and improvement of outcome after aneurysmal subarachnoid hemorrhage.

    PubMed

    Etminan, Nima; Macdonald, R Loch; Davis, Cara; Burton, Kevin; Steiger, Hans-Jakob; Hänggi, Daniel

    2015-01-01

    The effective reduction of delayed cerebral ischemia (DCI), a main contributor for poor outcome following aneurysmal subarachnoid hemorrhage (SAH), remains challenging. Previous clinical trials on systemic pharmaceutical treatment of SAH mostly failed to improve outcome, probably because of insensitive pharmaceutical targets and outcome measures, small sample size, insufficient subarachnoid drug concentrations and also detrimental, systemic effects of the experimental treatment per se. Interestingly, in studies that are more recent, intrathecal administration of nicardipine pellets following surgical aneurysm repair was suggested to have a beneficial effect on DCI and neurological outcome. However, this positive effect remained restricted to patients who were treated surgically for a ruptured aneurysm. Because of the favorable results of the preclinical data on DCI and neurological outcome in the absence of neurotoxicity or systemic side effects, we are initiating clinical trials. The PROMISE (Prolonged Release nimOdipine MIcro particles after Subarachnoid hemorrhage) trial is designed as an unblinded, nonrandomized, single-center, single-dose, dose-escalation safety and tolerability phase 1 study in patients surgically treated for aSAH and will investigate the effect of intracisternal EG-1962 administration. The NEWTON (Nimodipine microparticles to Enhance recovery While reducing TOxicity after subarachNoid hemorrhage) trial is a phase 1/2a multicenter, controlled, randomized, open-label, dose-escalation, safety, tolerability, and pharmacokinetic study comparing EG-1962 and nimodipine in patients with aneurysmal SAH.

  15. Decompression to altitude: assumptions, experimental evidence, and future directions.

    PubMed

    Foster, Philip P; Butler, Bruce D

    2009-02-01

    Although differences exist, hypobaric and hyperbaric exposures share common physiological, biochemical, and clinical features, and their comparison may provide further insight into the mechanisms of decompression stress. Although altitude decompression illness (DCI) has been experienced by high-altitude Air Force pilots and is common in ground-based experiments simulating decompression profiles of extravehicular activities (EVAs) or astronauts' space walks, no case has been reported during actual EVAs in the non-weight-bearing microgravity environment of orbital space missions. We are uncertain whether gravity influences decompression outcomes via nitrogen tissue washout or via alterations related to skeletal muscle activity. However, robust experimental evidence demonstrated the role of skeletal muscle exercise, activities, and/or movement in bubble formation and DCI occurrence. Dualism of effects of exercise, positive or negative, on bubble formation and DCI is a striking feature in hypobaric exposure. Therefore, the discussion and the structure of this review are centered on those highlighted unresolved topics about the relationship between muscle activity, decompression, and microgravity. This article also provides, in the context of altitude decompression, an overview of the role of denitrogenation, metabolic gases, gas micronuclei, stabilization of bubbles, biochemical pathways activated by bubbles, nitric oxide, oxygen, anthropometric or physiological variables, Doppler-detectable bubbles, and potential arterialization of bubbles. These findings and uncertainties will produce further physiological challenges to solve in order to line up for the programmed human return to the Moon, the preparation for human exploration of Mars, and the EVAs implementation in a non-zero gravity environment.

  16. Insecticide resistance of adults and nymphs of Asian citrus psyllid populations from Apatzingán Valley, Mexico.

    PubMed

    Pardo, Saúl; Martínez, Ana M; Figueroa, José I; Chavarrieta, Juan M; Viñuela, Elisa; Rebollar-Alviter, Ángel; Miranda, Mario A; Valle, Javier; Pineda, Samuel

    2018-01-01

    Control of the Asian citrus psyllid Diaphorina citri Kuwayama, the most important pest of citrus worldwide, is based on the use of insecticides, though unsatisfactory results have recently been reported. In this study, insecticide resistance of D. citri to three insecticides (bifenthrin, malathion, and chlorpyrifos) was examined. Three populations (designated Dci-CParácuaro, Dci-El Junco, and Dci-Antúnez) of both adults and fourth-instar D. citri individuals were collected in 2014 at two different times and on one occasion, respectively, from three locations (Crucero de Parácuaro, El Junco, and Antúnez). These locations represent the major commercial Mexican lemon production areas in the Apatzingán Valley in the state of Michoacán, Mexico. The three populations of D. citri adults and fourth-instar nymphs at the different collection times showed low levels of resistance (≤7-fold) to bifenthrin, but were very resistant to malathion (≤345- and ≤432-fold for adults and fourth instars, respectively) and chlorpyrifos (≤2435- and ≤1424-fold for adults and fourth instars, respectively). Resistance levels to the tested insecticides were highly variable but homogeneous among seasons and localities. Resistance management programmes that include crop sanitation, use of biological and cultural control practices, and rotation of insecticide classes should be established, particularly in areas where D. citri has developed resistance to malathion and chlorpyrifos. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. Dyadic coping in Latino couples: validity of the Spanish version of the Dyadic Coping Inventory.

    PubMed

    Falconier, Mariana Karin; Nussbeck, Fridtjof; Bodenmann, Guy

    2013-01-01

    This study seeks to validate the Spanish version of the Dyadic Coping Inventory (DCI) in a Latino population with data from 113 heterosexual couples. Results for both partners confirm the factorial structure for the Spanish version (Subscales: Stress Communication, Emotion- and Problem-Focused Supportive, Delegated, and Negative Dyadic Coping, Emotion- and Problem-Focused Common Dyadic Coping, and Evaluation of Dyadic Coping; Aggregated Scales: Dyadic Coping by Oneself and by Partner) and support the discriminant validity of its subscales and the concurrent, and criterion validity of the subscales and aggregated scales. These results do not only indicate that the Spanish version of the DCI can be used reliably as a measure of coping in Spanish-speaking Latino couples, but they also suggest that this group relies on dyadic coping frequently and that this type of coping is associated with positive relationship functioning and individual coping. Limitations and implications are discussed.

  18. Continuing professional development of dentists through distant learning: an Indira Gandhi National Open University-Dental Council of India experiment a report.

    PubMed

    Kuba, Ruchika; Kohli, Anil

    2014-01-01

    To keep themselves updated with all the advancements in the field of dentistry, dentists should involve themselves in some kind of professional development. Distance learning is the most appropriate way to serve the growing demand due to technological advancements. Indira Gandhi National Open University in collaboration with Dental Council of India (DCI) developed and launched two continuing professional development programs in Endodontics (postgraduate certificate in endodontics) and postgraduate certificate in oral implantology and has trained over 400 and 280 BDS dentists respectively till date. The program package consists of self-instructional material, assignments, videos and practical training. The training is conducted in premiere dental colleges and institutions recognized by DCI. The certificate is awarded after a term end examination, both in theory and practical. The pass percentages of the theory courses ranged from around 63% to 98%, and 90% of the candidates cleared the practical exam.

  19. Cardiac Imaging System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Although not available to all patients with narrowed arteries, balloon angioplasty has expanded dramatically since its introduction with an estimated further growth to 562,000 procedures in the U.S. alone by 1992. Growth has fueled demand for higher quality imaging systems that allow the cardiologist to be more accurate and increase the chances of a successful procedure. A major advance is the Digital Cardiac Imaging (DCI) System designed by Philips Medical Systems International, Best, The Netherlands and marketed in the U.S. by Philips Medical Systems North America Company. The key benefit is significantly improved real-time imaging and the ability to employ image enhancement techniques to bring out added details. Using a cordless control unit, the cardiologist can manipulate images to make immediate assessment, compare live x-ray and roadmap images by placing them side-by-side on monitor screens, or compare pre-procedure and post procedure conditions. The Philips DCI improves the cardiologist's precision by expanding the information available to him.

  20. Failure Mechanisms and Damage Model of Ductile Cast Iron Under Low-Cycle Fatigue Conditions

    NASA Astrophysics Data System (ADS)

    Wu, Xijia; Quan, Guangchun; MacNeil, Ryan; Zhang, Zhong; Sloss, Clayton

    2014-10-01

    Strain-controlled low-cycle fatigue (LCF) tests were conducted on ductile cast iron (DCI) at strain rates of 0.02, 0.002, and 0.0002/s in the temperature range from room temperature to 1073 K (800 °C). A constitutive-damage model was developed within the integrated creep-fatigue theory (ICFT) framework on the premise of strain decomposition into rate-independent plasticity and time-dependent creep. Four major damage mechanisms: (i) plasticity-induced fatigue, (ii) intergranular embrittlement (IE), (iii) creep, and (iv) oxidation were considered in a nonlinear creep-fatigue interaction model which represents the overall damage accumulation process consisting of oxidation-assisted fatigue crack nucleation and propagation in coalescence with internally distributed damage ( e.g., IE and creep), leading to final fracture. The model was found to agree with the experimental observations of the complex DCI-LCF phenomena, for which the linear damage summation rule would fail.

  1. Developmental dysplasia of the hip in the newborn: A systematic review

    PubMed Central

    Gulati, Vivek; Eseonu, Kelechi; Sayani, Junaid; Ismail, Nizar; Uzoigwe, Chika; Choudhury, Muhammed Zaki; Gulati, Pooja; Aqil, Adeel; Tibrewal, Saket

    2013-01-01

    Developmental dysplasia of the hip (DDH) denotes a wide spectrum of conditions ranging from subtle acetabular dysplasia to irreducible hip dislocations. Clinical diagnostic tests complement ultrasound imaging in allowing diagnosis, classification and monitoring of this condition. Classification systems relate to the alpha and beta angles in addition to the dynamic coverage index (DCI). Screening programmes for DDH show considerable geographic variation; certain risk factors have been identified which necessitate ultrasound assessment of the newborn. The treatment of DDH has undergone significant evolution, but the current gold standard is still the Pavlik harness. Duration of Pavlik harness treatment has been reported to range from 3 to 9.3 mo. The beta angle, DCI and the superior/lateral femoral head displacement can be assessed via ultrasound to estimate the likelihood of success. Success rates of between 7% and 99% have been reported when using the harness to treat DDH. Avascular necrosis remains the most devastating complication of harness usage with a reported rate of between 0% and 28%. Alternative non-surgical treatment methods used for DDH include devices proposed by LeDamany, Frejka, Lorenz and Ortolani. The Rosen splint and Wagner stocking have also been used for DDH treatment. Surgical treatment for DDH comprises open reduction alongside a combination of femoral or pelvic osteotomies. Femoral osteotomies are carried out in cases of excessive anteversion or valgus deformity of the femoral neck. The two principal pelvic osteotomies most commonly performed are the Salter osteotomy and Pemberton acetabuloplasty. Serious surgical complications include epiphyseal damage, sciatic nerve damage and femoral neck fracture. PMID:23610749

  2. Sedation of Patients with Acute Aneurysmal Subarachnoid Hemorrhage with Ketamine Is Safe and Might Influence the Occurrence of Cerebral Infarctions Associated with Delayed Cerebral Ischemia.

    PubMed

    Von der Brelie, Christian; Seifert, Michael; Rot, Sergej; Tittel, Anja; Sanft, Carsten; Meier, Ullrich; Lemcke, Johannes

    2017-01-01

    Ketamine has neuroprotective characteristics as well as beneficial cardiocirculatory properties and may thus reduce vasopressor consumption. In contrast, sedation with ketamine (like any other sedative drug) has side effects. This study assesses the influence of ketamine on intracranial pressure (ICP), on the consumption of vasopressors in induced hypertension therapy, and on the occurrence of delayed cerebral ischemia (DCI)-associated cerebral infarctions, with particular focus on the complications of sedation in patients with aneurysmal subarachnoid hemorrhage (SAH). This is a retrospective, observational study. Sixty-five patients with SAH who underwent a period of sedation were included. The clinical course variables (Richmond Agitation and Sedation scale score, ICP values, consumption of vasopressors, complications of sedation, outcome, and other clinical parameters) were analyzed. Cranial computed tomography results were analyzed. Forty-one patients underwent sedation including ketamine (63.1%). Ketamine decreased the ICP in 92.7% of the cases. Vasopressors was reduced in 53.6%. DCI-associated cerebral infarctions occurred significantly less often in the patient cohort being treated with sedation including ketamine (7.3% vs. 25% in the nonketamine group; P = 0.04). The rate of major complications was not higher in the ketamine group. Outcome was not different regarding the groups if they were sedated with or without ketamine. Ketamine decreases the ICP and is not associated with a higher rate of complications. The rate of DCI-associated cerebral infarctions was lower in the ketamine group. Ketamine administration led to a reduction of vasopressors used for induced hypertension. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Plant utilization against digestive system disorder in Southern Assam, India.

    PubMed

    Choudhury, Prakash Roy; Choudhury, Manabendra Dutta; Ningthoujam, Sanjoy Singh; Mitra, Abhijit; Nath, Deepa; Talukdar, Anupam Das

    2015-12-04

    Being one of the most common types of life threatening diseases in Southern Assam, India, the digestive system disorders (DSD) have gained much attention in recent decades. Traditional beliefs and inadequate income of mass population result in the use of alternative phytotherapies to treat the diseases. The present paper documents the medicinal knowledge and utilization of plants for treatment of digestive system disorders in Southern Assam, India by Disease Consensus Index (DCI). It also determines the most suitable plant species used to treat digestive system disorders in the study area. The study was based on ethnomedicinal field survey covering a period of 1 year from 2014-2015. The ethnomedicinal information was collected by using semi-structured questionnaires from different traditional Bengali people having knowledge on medicinal plants. Collected data were analyzed by calculating DCI. During the survey, 29 informants were interviewed and a total of 49 plants under 46 genera belonging to 33 families were listed. Data analysis revealed that Litsea glutinosa, Momordica charantia, Andrographis paniculata, Lawsonia inermis, Cleome viscosa, Psidium guajava, Ageratum conyzoides, Cuscuta reflexa, Cynodon dactylon and Carica papaya are the most prominent plants among the people of Southern Assam for treating DSD. This explorative survey emphasizes the need to preserve and document the traditional healing practices for managing DSD inviting for more imminent scientific research on the plants to determine their efficacy as well as safety. With the help of statistical analysis (DCI), we propose 10 priority plants for DSD in present work. Systematic pharmacological study with these plants may contribute significant result. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. 'Sea legs': sharpened Romberg test after three days on a live-aboard dive boat.

    PubMed

    Gibbs, Clinton R; Commons, Katherine H; Brown, Lawrence H; Blake, Denise F

    2010-12-01

    The sharpened Romberg test (SRT) is commonly used by diving and hyperbaric physicians as an indicator of neurological decompression illness (DCI). People who spend a prolonged time on a boat at sea experience impairment in their balance on returning to shore, a condition known as mal de debarquement ('sea legs'). This conditioning of the vestibular system to the rocking motion of a boat at sea may impact on the utility of the SRT in assessing a diver with potential DCI after a live-aboard dive trip. To assess the impact 'sea legs' has on the SRT after three days on a live-aboard dive trip. Thirty-nine staff and passengers of a three-day, live-aboard dive trip performed a SRT before and after their journey, with assessment of potential variables, including middle ear barotrauma, alcohol consumption, sea-sickness and occult DCI. There was no statistically significant impact on SRT performance, with 100% completion pre-trip and 35 out of 36 divers (97.2%) post-trip. There were trends towards more attempts being required and time needed for successful SRT post-trip, but these were not statistically significant. There was a small, but noteworthy incidence of middle-ear barotrauma, with seven people affected pre-trip, and 13 post-trip. There was a higher incidence in student divers. Middle-ear barotrauma did not appear to have a direct impact on SRT performance. There was no significant impact on SRT performance resulting from 'sea legs' after three days at sea. Recreational divers, especially dive students, have a substantial incidence of mild middle ear barotrauma.

  5. Subconjunctival dendrimer-drug therapy for the treatment of dry eye in rabbits with induced autoimmune dacryoadenitis.

    PubMed

    Lin, Hui; Liu, Ying; Kambhampati, Siva P; Hsu, Chih-Chien; Kannan, Rangaramanujam M; Yiu, Samuel C

    2018-05-16

    To investigate the efficacy of a single subconjunctival injection of dendrimer-dexamethasone to treat dry eye in a rabbit model of induced autoimmune dacryoadenitis (AID). Dendrimer biodistribution after subconjuntival injection in AID animals was evaluated using Cy5-labelled dendrimer (D-Cy5) and confocal microscopy. Diseased animals were treated with free dexamethasone (Free-Dex), dendrimer-dexamethasone (D-Dex), or saline via a single subconjunctival injection. The efficacy was evaluated using various clinical evaluations, such as Schirmer's test, tear breakup time (TBUT), and fluorescein and rose bengal staining. Histopathology was evaluated by H&E staining and immunostaining. Levels of inflammatory cytokines and aquaporin proteins in the LGs were determined by real-time PCR. Subconjunctivally administered dendrimers selectively localized in the inflamed LGs, and were taken up by the infiltrated cells. At two weeks post-treatment, the D-Dex group showed improved clinical evaluations. No significant changes were observed in other groups. H&E staining demonstrated, less inflammatory cell infiltration and fewer atrophic acini in D-Dex group, compared to those treated with saline or Free-Dex. Immunohistochemistry demonstrated that the intensity of CD-18 (+) and RTLA (+) was weaker in LGs in the D-Dex group than in other treatment rabbits. Pro-inflammatory gene expression levels of MMP9, IL6, IL8, and TNFα were significantly decreased in the D-Dex group compared to the saline group. The dendrimer exhibits pathology-dependent biodistribution in the inflamed LGs. Subconjunctivally administered D-Dex suppressed LG inflammation, leading to partial recovery of LG function with clinical improvement in induced AID. Sjögren's patients may benefit from this targeted nanomedicine approach. Copyright © 2018. Published by Elsevier Inc.

  6. Comparison of induced hypertension, fluid bolus, and blood transfusion to augment cerebral oxygen delivery after subarachnoid hemorrhage.

    PubMed

    Dhar, Rajat; Scalfani, Michael T; Zazulia, Allyson R; Videen, Tom O; Derdeyn, Colin P; Diringer, Michael N

    2012-03-01

    Critical reductions in oxygen delivery (DO(2)) underlie the development of delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH). If DO(2) is not promptly restored, then irreversible injury (that is, cerebral infarction) may result. Hemodynamic therapies for DCI (that is, induced hypertension [IH] and hypervolemia) aim to improve DO(2) by raising cerebral blood flow (CBF). Red blood cell (RBC) transfusion may be an alternate strategy that augments DO(2) by improving arterial O(2) content. The authors compared the relative ability of these 3 interventions to improve cerebral DO(2), specifically their ability to restore DO(2) to regions where it is impaired. The authors compared 3 prospective physiological studies in which PET imaging was used to measure global and regional CBF and DO(2) before and after the following treatments: 1) fluid bolus of 15 ml/kg normal saline (9 patients); 2) raising mean arterial pressure 25% (12 patients); and 3) transfusing 1 U of RBCs (17 patients) in 38 individuals with aneurysmal SAH at risk for DCI. Response between groups in regions with low DO(2) (< 4.5 ml/100 g/min) was compared using repeated-measures ANOVA. Groups were similar except that the fluid bolus cohort had more patients with symptoms of DCI and lower baseline CBF. Global CBF or DO(2) did not rise significantly after any of the interventions, except after transfusion in patients with hemoglobin levels < 9 g/dl. All 3 treatments improved CBF and DO(2) to regions with impaired baseline DO(2), with a greater improvement after transfusion (23%) than hypertension (14%) or volume loading (10%); p < 0.001. Transfusion also resulted in a nonsignificantly greater (47%) reduction in the number of brain regions with low DO(2) when compared with fluid bolus (7%) and hypertension (12%) (p = 0.33). The IH, fluid bolus, and blood transfusion interventions all improve DO(2) to vulnerable brain regions at risk for ischemia after SAH. Transfusion appeared to provide a physiological benefit at least comparable to IH, especially among patients with anemia, but transfusion is associated with risks. The clinical significance of these findings remains to be established in controlled clinical trials.

  7. Breed of cow and herd productivity affect milk nutrient recovery in curd, and cheese yield, efficiency and daily production.

    PubMed

    Stocco, G; Cipolat-Gotet, C; Gasparotto, V; Cecchinato, A; Bittante, G

    2018-02-01

    Little is known about cheese-making efficiency at the individual cow level, so our objective was to study the effects of herd productivity, individual herd within productivity class and breed of cow within herd by producing, then analyzing, 508 model cheeses from the milk of 508 cows of six different breeds reared in 41 multi-breed herds classified into two productivity classes (high v. low). For each cow we obtained six milk composition traits; four milk nutrient (fat, protein, solids and energy) recovery traits (REC) in curd; three actual % cheese yield traits (%CY); two theoretical %CYs (fresh cheese and cheese solids) calculated from milk composition; two overall cheese-making efficiencies (% ratio of actual to theoretical %CYs); daily milk yield (dMY); and three actual daily cheese yield traits (dCY). The aforementioned phenotypes were analyzed using a mixed model which included the fixed effects of herd productivity, parity, days in milk (DIM) and breed; the random effects were the water bath, vat, herd and residual. Cows reared in high-productivity herds yielded more milk with higher nutrient contents and more cheese per day, had greater theoretical %CY, and lower cheese-making efficiency than low-productivity herds, but there were no differences between them in terms of REC traits. Individual herd within productivity class was an intermediate source of total variation in REC, %CY and efficiency traits (10.0% to 17.2%), and a major source of variation in milk yield and dCY traits (43.1% to 46.3%). Parity of cows was an important source of variation for productivity traits, whereas DIM affected almost all traits. Breed within herd greatly affected all traits. Holsteins produced more milk, but Brown Swiss cows produced milk with higher actual and theoretical %CYs and cheese-making efficiency, so that the two large-framed breeds had the same dCY. Compared with the two large-framed breeds, the small Jersey cows produced much less milk, but with greater actual and theoretical %CYs, similar efficiencies and a slightly lower dCY. Compared with the average of the specialized dairy breeds, the three dual-purpose breeds (Simmental and the local Rendena and Alpine Grey) had, on average, similar dMY, lower actual and theoretical %CY, similar fat and protein REC, and slightly greater cheese-making efficiency.

  8. Quality of preimplantation embryos recovered in vivo from dairy cows in relation to their body condition.

    PubMed

    Makarevich, A V; Stádník, L; Kubovičová, E; Hegedüšová, Z; Holásek, R; Louda, F; Beran, J; Nejdlová, M

    2016-06-01

    This study examined the impact of cow body condition on the quality of bovine preimplantation embryos. The embryos (n = 107) were flushed from dairy cows and classified according to a five-point scale body condition score (BCS2 n = 17; BCS3 n = 31; BCS4 n = 11) on the 7th day after insemination and then analyzed for development, dead cell index (DCI), cell number and actin cytoskeleton quality. The highest embryo recovery rate (P < 0.05) was recorded in the BCS3 group and the lowest in the BCS4 group. More transferable (morula, blastocyst) embryos were obtained from the BCS4 cows (79%), compared with the BCS2 (64%) or BCS3 (63%) animals. However, cell numbers were higher in the BCS2 and BCS3 groups (P < 0.05) compared with the BCS4 embryos. Conversely, the DCI was lowest in the BCS2 (3.88%; P < 0.05) and highest in the BCS4 (6.56%) embryos. The proportion of embryos with the best actin quality (grade I) was higher in the BCS2 and BCS3 cows compared with the BCS4 group. Almost 25% of all embryos showed fragmented morphology and a higher DCI (5.65%) than normal morulas (1.76%). More fragmented embryos were revealed in the BCS2 (28.6%) and BCS4 (31.25%) groups, and less (19.15%) in the BCS3 group. The cell numbers in such embryos were lower in the BCS4 (22.57) than in the BCS2 (46.25) or BCS3 (42.4) groups. In conclusion, the body condition of dairy cows affects the quality of preimplantation embryos. A BCS over 3.0 resulted in a higher incidence of poor (fragmented) embryos.

  9. High-resolution Manometry and Globus: Comparison of Globus, Gastroesophageal Reflux Disease and Normal Controls Using High-resolution Manometry.

    PubMed

    Choi, Won Seok; Kim, Tae Wan; Kim, Ja Hyun; Lee, Sang Hyuk; Hur, Woon Je; Choe, Young Gil; Lee, Sang Hyuk; Park, Jung Ho; Sohn, Chong Il

    2013-10-01

    Globus is a foreign body sense in the throat without dysphagia, odynophagia, esophageal motility disorders, or gastroesophageal reflux. The etiology is unclear. Previous studies suggested that increased upper esophageal sphincter pressure, gastroesophageal reflux and hypertonicity of esophageal body were possible etiologies. This study was to quantify the upper esophageal sphincter (UES) pressure, contractile front velocity (CFV), proximal contractile integral (PCI), distal contractile integral (DCI) and transition zone (TZ) in patient with globus gastroesophageal reflux disease (GERD) without globus, and normal controls to suggest the correlation of specific high-resolution manometry (HRM) findings and globus. Fifty-seven globus patients, 24 GERD patients and 7 normal controls were studied with HRM since 2009. We reviewed the reports, and selected 5 swallowing plots suitable for analysis in each report, analyzed each individual plot with ManoView. The 5 parameters from each plot in 57 globus patients were compared with that of 24 GERD patients and 7 normal controls. There was no significant difference in the UES pressure, CFV, PCI and DCI. TZ (using 30 mmHg isobaric contour) in globus showed significant difference compared with normal controls and GERD patients. The median values of TZ were 4.26 cm (interquartile range [IQR], 2.30-5.85) in globus patients, 5.91 cm (IQR, 3.97-7.62) in GERD patients and 2.26 cm (IQR, 1.22-2.92) in normal controls (P = 0.001). HRM analysis suggested that UES pressure, CFV, PCI and DCI were not associated with globus. Instead increased length of TZ may be correlated with globus. Further study comparing HRM results in globus patients within larger population needs to confirm their correlation.

  10. Multiple Rapid Swallow Maneuver Enhances the Clinical Utility of High-Resolution Manometry in Patients Showing Ineffective Esophageal Motility

    PubMed Central

    Min, Yang Won; Shin, Inseub; Son, Hee Jung; Rhee, Poong-Lyul

    2015-01-01

    Abstract The clinical significance of ineffective esophageal motility (IEM) together with multiple rapid swallow (MRS) has not been yet evaluated in the Chicago Classification v3.0. This study evaluated the adjunctive role of MRS in IEM and determined the criteria of abnormal MRS to maximize the utility of IEM. We analyzed 186 patients showing IEM or normal esophageal motility (NEM), who underwent esophageal high-resolution impedance–manometry for esophageal symptoms. Two different criteria for abnormal MRS were applied to IEM subjects, resulting in 2 corresponding subgroups: IEM-A when distal contractile integral (DCI) ratio between an average wet swallows and MRS contraction was <1 and IEM-B when MRS contraction DCI was <450 mm Hg-s-cm. One IEM subject inadequately performed MRS. Among the remaining 52 IEM subjects, 18 (34.6%) were classified into IEM-A and 23 (44.2%) into IEM-B. IEM subjects showed less complete bolus transit (median 0.0%, interquartile range 0.0–20.0% vs 60.0%, 30.0–80.0; P < 0.001) resulting in higher impaired bolus transit than NEM subjects (98.1% vs 66.9%, P = 0.001). IEM-B subjects showed additionally higher pathologic bolus exposure than NEM subjects (55.6% vs 29.3%, P = 0.001), whereas IEM-A subjects could not. Although IEM-B subjects had the highest prevalence of gastroesophageal reflux disease among the subjects groups, it did not reach statistical significance. In conclusion, IEM patients with abnormal MRS contraction have an increased risk of prolonged bolus clearance, poor bolus transit, and pathologic bolus exposure. IEM patients need to be assessed concerning whether MRS contraction DCI is <450 mm Hg-s-cm to segregate clinically relevant patients. PMID:26448010

  11. High-resolution Manometry and Globus: Comparison of Globus, Gastroesophageal Reflux Disease and Normal Controls Using High-resolution Manometry

    PubMed Central

    Choi, Won Seok; Kim, Tae Wan; Kim, Ja Hyun; Lee, Sang Hyuk; Hur, Woon Je; Choe, Young Gil; Lee, Sang Hyuk; Park, Jung Ho

    2013-01-01

    Background/Aims Globus is a foreign body sense in the throat without dysphagia, odynophagia, esophageal motility disorders, or gastroesophageal reflux. The etiology is unclear. Previous studies suggested that increased upper esophageal sphincter pressure, gastroesophageal reflux and hypertonicity of esophageal body were possible etiologies. This study was to quantify the upper esophageal sphincter (UES) pressure, contractile front velocity (CFV), proximal contractile integral (PCI), distal contractile integral (DCI) and transition zone (TZ) in patient with globus gastroesophageal reflux disease (GERD) without globus, and normal controls to suggest the correlation of specific high-resolution manometry (HRM) findings and globus. Methods Fifty-seven globus patients, 24 GERD patients and 7 normal controls were studied with HRM since 2009. We reviewed the reports, and selected 5 swallowing plots suitable for analysis in each report, analyzed each individual plot with ManoView. The 5 parameters from each plot in 57 globus patients were compared with that of 24 GERD patients and 7 normal controls. Results There was no significant difference in the UES pressure, CFV, PCI and DCI. TZ (using 30 mmHg isobaric contour) in globus showed significant difference compared with normal controls and GERD patients. The median values of TZ were 4.26 cm (interquartile range [IQR], 2.30-5.85) in globus patients, 5.91 cm (IQR, 3.97-7.62) in GERD patients and 2.26 cm (IQR, 1.22-2.92) in normal controls (P = 0.001). Conclusions HRM analysis suggested that UES pressure, CFV, PCI and DCI were not associated with globus. Instead increased length of TZ may be correlated with globus. Further study comparing HRM results in globus patients within larger population needs to confirm their correlation. PMID:24199007

  12. Effect and Feasibility of Therapeutic Hypothermia in Patients with Hemorrhagic Stroke: A Systematic Review and Meta-Analysis.

    PubMed

    Yao, Zhong; You, Chao; He, Min

    2018-03-01

    Therapeutic hypothermia (TH) has shown good results in experimental models of hemorrhagic stroke. The clinical application of TH, however, remains controversial, since reports regarding its therapeutic effect are inconsistent. We conducted a systematic review based on Preferred Reporting Items for Systematic Reviews and Meta-analyses comparing TH with a control group in terms of mortality, poor outcome, delayed cerebral ischemia (DCI), and specific complications. The subgroup analyses were stratified by study type, country, mean age, hemorrhage type, cooling method, treatment duration, rewarming velocity, and follow-up time. Nine studies were included, most of which were of moderate quality. The overall effect demonstrated insignificant differences in mortality (risk ratio [RR] 0.78; 95% confidence interval [CI] 0.58-1.06; P = 0.11) and poor outcome rate (RR 0.89; 95% CI 0.70-1.12; P = 0.32) between TH and the control group. However, sensitivity analyses, after we omitted 1 study, achieved a statistically significant difference in poor outcome favoring TH. Moreover, in the subgroup analyses, the results derived from randomized studies revealed that TH significantly reduced poor outcomes (RR 0.40; 95% CI 0.22-0.74; P = 0.003). In addition, TH significantly reduced DCI compared with control (RR 0.61; 95% CI 0.40-0.93; P = 0.02). The incidence of specific complications (rebleeding, pneumonia, sepsis, arrhythmia, and hydrocephalus) between the 2 groups were comparable and did not reach significant difference. The overall effect showed TH did not significantly reduce mortality and poor outcomes but led to a decreased incidence of DCI. Compared with control, TH resulted in comparable incidences of specific complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Acute cardiac support with intravenous milrinone promotes recovery from early brain injury in a murine model of severe subarachnoid haemorrhage.

    PubMed

    Mutoh, Tomoko; Mutoh, Tatsushi; Nakamura, Kazuhiro; Yamamoto, Yukiko; Tsuru, Yoshiharu; Tsubone, Hirokazu; Ishikawa, Tatsuya; Taki, Yasuyuki

    2017-04-01

    Early brain injury/ischaemia (EBI) is a serious complication early after subarachnoid haemorrhage (SAH) that contributes to development of delayed cerebral ischaemia (DCI). This study aimed to determine the role of inotropic cardiac support using milrinone (MIL) on restoring acute cerebral hypoperfusion attributable to EBI and improving outcomes after experimental SAH. Forty-three male C57BL/6 mice were assigned to either sham surgery (SAH-sham), SAH induced by endovascular perforation plus postconditioning with 2% isoflurane (Control), or SAH plus isoflurane combined with MIL with and without hypoxia-inducible factor inhibitor (HIF-I) pretreatment. Cardiac output (CO) during intravenous MIL infusion (0.25-0.75 μg/kg/min) between 1.5 and 2.5 hours after SAH induction was monitored with Doppler echocardiography. Magnetic resonance imaging (MRI)-continuous arterial spin labelling was used for quantitative cerebral blood flow (CBF) measurements. Neurobehavioral function was assessed daily by neurological score and open field test. DCI was analyzed 3 days later by determining infarction on MRI. Mild reduction of cardiac output (CO) and global cerebral blood flow (CBF) depression were notable early after SAH. MIL increased CO in a dose-dependent manner (P<.001), which was accompanied by improved hypoperfusion, incidence of DCI and functional recovery than Control (P<.05). The neuroprotective effects afforded by MIL or Control were attenuated by hypoxia-inducible factor (HIF) inhibition (P<.05). These results suggest that MIL improves acute hypoperfusion by its inotropic effect, leading to neurobehavioral improvement in mice after severe SAH, in which HIF may be acting as a critical mediator. © 2017 John Wiley & Sons Australia, Ltd.

  14. Utilizing mobile networks for the detection of clinically relevant interactions between chemotherapy regimens and complementary and alternative medicines.

    PubMed

    Yap, Kevin Yi-Lwern; See, Cheng Shang; Kuo, En Yi; Chui, Wai Keung; Chan, Alexandre

    2012-02-01

    Patients with cancer who use complementary and alternative medicines (CAMs) in conjunction with chemotherapy treatment are at risk of manifesting anticancer drug-CAM interactions (DCIs), which may lead to negative therapeutic outcomes. This article describes a novel iPhone application developed for the Mobile Internet, called OncoRx-MI, which identifies DCIs of single-agent and multiple-agent chemotherapy regimen (CReg) prescriptions. Drug-, CAM-, and DCI-related information was compiled from various hardcopy and softcopy sources, and published literature from PubMed. Overall management plans for the CRegs were then developed. The iPhone Web documents were constructed using Adobe software and programming scripts, and mounted onto a third-party server. DCI searches are based on CReg acronyms, and OncoRx-MI is designed to fit the iPhone screen configuration for improved usability. A small usability study was also carried out and the user feedback presented. OncoRx-MI is able to detect over 2700 interactions between 256 CRegs and 166 CAMs, making up a total of over 4400 DCI pairs. The CAMs are classified into seven categories based on their uses in supportive care, and non-cancer-related CAMs are also included. The majority of the DCIs are pharmacokinetic in nature (79%), involving the induction and inhibition of the cytochrome P450 isozymes and p-glycoprotein. Pharmacodynamic DCIs include hepatotoxicity (39%), altered corticosteroid efficacies (30%), and increased risks of hypoglycemia (4%), hypertensive crisis (2%), bleeding, and serotonin syndrome (1% each). OncoRx-MI is the first mobile application of its kind that allows searching of DCIs for CRegs through 3G networks, and is intended to improve pharmaceutical care of patients with cancer by assisting health care practitioners in managing CReg interactions in their clinical practices.

  15. HIMALAIA (Hypertension Induction in the Management of AneurysmaL subArachnoid haemorrhage with secondary IschaemiA): a randomized single-blind controlled trial of induced hypertension vs. no induced hypertension in the treatment of delayed cerebral ischemia after subarachnoid hemorrhage.

    PubMed

    Gathier, C S; van den Bergh, W M; Slooter, A J C

    2014-04-01

    Delayed cerebral ischemia (DCI) is a major complication after aneurysmal subarachnoid hemorrhage (SAH). One option to treat delayed cerebral ischemia is to use induced hypertension, but its efficacy on the eventual outcome has not been proven in a randomized clinical trial. This article describes the design of the HIMALAIA trial (Hypertension Induction in the Management of AneurysmaL subArachnoid haemorrhage with secondary IschaemiA), designed to assess the effectiveness of induced hypertension on neurological outcome in patients with DCI after SAH. To investigate whether induced hypertension improves the functional outcome in patients with delayed cerebral ischemia after SAH. The HIMALAIA trial is a multicenter, singe-blinded, randomized controlled trial in patients with DCI after a recent SAH. Eligible patients will be randomized to either induced hypertension (n = 120) or to no induced hypertension (n = 120). In selected centers, the efficacy of induced hypertension in augmenting cerebral blood flow will be measured by means of cerebral perfusion computerized tomography scanning. Follow-up assessments will be performed at 3 and 12 months after randomization by trial nurses who are blinded to the treatment allocation and management. We will include patients during five years. The primary outcome is the proportion of subarachnoid hemorrhage patients with delayed cerebral ischemia with poor outcome three-months after randomization, defined as a modified Rankin scale of more than 3. Secondary outcome measures are related to treatment failure, functional outcome, adverse events, and cerebral hemodynamics. The HIMALAIA trial is registered at clinicaltrials.gov under identifier NCT01613235. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.

  16. Quantification of myo-inositol, 1,5-anhydro-D-sorbitol, and D-chiro-inositol using high-performance liquid chromatography with electrochemical detection in very small volume clinical samples

    PubMed Central

    Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.

    2015-01-01

    Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453

  17. Systems and technologies for high-speed inter-office/datacenter interface

    NASA Astrophysics Data System (ADS)

    Sone, Y.; Nishizawa, H.; Yamamoto, S.; Fukutoku, M.; Yoshimatsu, T.

    2017-01-01

    Emerging requirements for inter-office/inter-datacenter short reach links for data center interconnects (DCI) and metro transport networks have led to various inter-office and inter-datacenter optical interface technologies. These technologies are bringing significant changes to systems and network architectures. In this paper, we present a system and ZR optical interface technologies for DCI and metro transport networks, then introduce the latest challenges facing the system framework. There are two trends in reach extension; one is to use Ethernet and the other is to use digital coherent technologies. The first approach achieves reach extension while using as many existing Ethernet components as possible. It offers low costs as reuses the cost-effective components created for the large Ethernet market. The second approach adopts low-cost and low power coherent DSPs that implement the minimal set long haul transmission functions. This paper introduces an architecture that integrates both trends. The architecture satisfies both datacom and telecom needs with a common control and management interface and automated configuration.

  18. Precision medicine of aneurysmal subarachnoid hemorrhage, vasospasm and delayed cerebral ischemia.

    PubMed

    Burrell, Christian; Avalon, Nicole E; Siegel, Jason; Pizzi, Michael; Dutta, Tumpa; Charlesworth, M Cristine; Freeman, William D

    2016-11-01

    Precision medicine provides individualized treatment of diseases through leveraging patient-to-patient variation. Aneurysmal subarachnoid hemorrhage carries tremendous morbidity and mortality with cerebral vasospasm and delayed cerebral ischemia proving devastating and unpredictable. Lack of treatment measures for these conditions could be improved through precision medicine. Areas covered: Discussed are the pathophysiology of CV and DCI, treatment guidelines, and evidence for precision medicine used for prediction and prevention of poor outcomes following aSAH. A PubMed search was performed using keywords cerebral vasospasm or delayed cerebral ischemia and either biomarkers, precision medicine, metabolomics, proteomics, or genomics. Over 200 peer-reviewed articles were evaluated. The studies presented cover biomarkers identified as predictive markers or therapeutic targets following aSAH. Expert commentary: The biomarkers reviewed here correlate with CV, DCI, and neurologic outcomes after aSAH. Though practical use in clinical management of aSAH is not well established, using these biomarkers as predictive tools or therapeutic targets demonstrates the potential of precision medicine.

  19. 3-Chlorotyrosine and 3,5-Dichlorotyrosine as biomarkers of respiratory tract exposure to chlorine gas

    EPA Science Inventory

    Modification of tyrosine by reactive chlorine can produce both 3-chlorotyrosine (CY) and 3,5-dichlorotyrosine (dCY). Both of these amino acids have proven to be promising biomarkers for assessing the extent of myeloperoxidase-catalyzed chlorine stress in a number of adverse physi...

  20. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2015-08-25

    DCI was not able to obtain the FDA Certificate of Sanitation for Armstrong because the sewage discharge is ahead of the water maker suction. The...unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 is to move the sewage discharge aft of the

  1. AIMES Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katz, Daniel S; Jha, Shantenu; Weissman, Jon

    2017-01-31

    This is the final technical report for the AIMES project. Many important advances in science and engineering are due to large-scale distributed computing. Notwithstanding this reliance, we are still learning how to design and deploy large-scale production Distributed Computing Infrastructures (DCI). This is evidenced by missing design principles for DCI, and an absence of generally acceptable and usable distributed computing abstractions. The AIMES project was conceived against this backdrop, following on the heels of a comprehensive survey of scientific distributed applications. AIMES laid the foundations to address the tripartite challenge of dynamic resource management, integrating information, and portable and interoperablemore » distributed applications. Four abstractions were defined and implemented: skeleton, resource bundle, pilot, and execution strategy. The four abstractions were implemented into software modules and then aggregated into the AIMES middleware. This middleware successfully integrates information across the application layer (skeletons) and resource layer (Bundles), derives a suitable execution strategy for the given skeleton and enacts its execution by means of pilots on one or more resources, depending on the application requirements, and resource availabilities and capabilities.« less

  2. AIMES Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weissman, Jon; Katz, Dan; Jha, Shantenu

    2017-01-31

    This is the final technical report for the AIMES project. Many important advances in science and engineering are due to large scale distributed computing. Notwithstanding this reliance, we are still learning how to design and deploy large-scale production Distributed Computing Infrastructures (DCI). This is evidenced by missing design principles for DCI, and an absence of generally acceptable and usable distributed computing abstractions. The AIMES project was conceived against this backdrop, following on the heels of a comprehensive survey of scientific distributed applications. AIMES laid the foundations to address the tripartite challenge of dynamic resource management, integrating information, and portable andmore » interoperable distributed applications. Four abstractions were defined and implemented: skeleton, resource bundle, pilot, and execution strategy. The four abstractions were implemented into software modules and then aggregated into the AIMES middleware. This middleware successfully integrates information across the application layer (skeletons) and resource layer (Bundles), derives a suitable execution strategy for the given skeleton and enacts its execution by means of pilots on one or more resources, depending on the application requirements, and resource availabilities and capabilities.« less

  3. Inositol as putative integrative treatment for PCOS.

    PubMed

    Genazzani, Alessandro D

    2016-12-01

    Studies over the last decade have demonstrated that some polycystic ovary syndrome (PCOS) patients have abnormal insulin sensitivity (insulin resistance), independently from being overweight or obese. This induces the risk of developing type 2 diabetes in such PCOS patients. The use of insulin sensitizers (i.e. metformin), reduces such metabolic, and most hormonal, impairments. As metformin often induces side effects, new integrative strategies have been proposed to treat insulin resistance, such as the use of inositols. Such compounds are mainly represented in humans by two inositol stereoisomers: myo-inositol (MYO) and d-chiro-inositol (DCI). MYO is the precursor of inositol triphosphate, a second messenger that regulates thyroid-stimulating hormone (TSH) and FSH as well as insulin. DCI derives from the conversion of myo-inositol via an insulin-dependent pathway. Several preliminary studies have indicated possible benefits of inositol therapy in PCOS patients, but to date no meta-analysis has been performed. This review aims to give clinical insights for the clinical use of inositol in PCOS. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  4. Final Technical Report for Automated Manufacturing of Innovative CPV/PV Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okawa, David

    Cogenra’s Dense Cell Interconnect system was designed to use traditional front-contact cells and string them together into high efficiency and high reliability “supercells”. This novel stringer allows one to take advantage of the ~100 GW/year of existing cell production capacity and create a solar product for the customer that will produce more power and last longer than traditional PV products. The goal for this program was for Cogenra Solar to design and develop a first-of-kind automated solar manufacturing line that produces strings of overlapping cells or “supercells” based on Cogenra’s Dense Cell Interconnect (DCI) technology for their Low Concentration Photovoltaicmore » (LCPV) systems. This will enable the commercialization of DCI technology to improve the efficiency, reliability and economics for their Low Concentration Photovoltaic systems. In this program, Cogenra Solar very successfully designed, developed, built, installed, and started up the ground-breaking manufacturing tools required to assemble supercells. Cogenra then successfully demonstrated operation of the integrated line at high yield and throughput far exceeding expectations. The development of a supercell production line represents a critical step toward a high volume and low cost Low Concentration Photovoltaic Module with Dense Cell Interconnect technology and has enabled the evaluation of the technology for reliability and yield. Unfortunately, performance and cost headwinds on Low Concentration Photovoltaics systems including lack of diffuse capture (10-15% hit) and more expensive tracker requirements resulted in a move away from LCPV technology. Fortunately, the versatility of Dense Cell Interconnect technology allows for application to flat plate module technology as well and Cogenra has worked with the DOE to utilize the learning from this grant to commercialize DCI technology for the solar market through the on-going grant: Catalyzing PV Manufacturing in the US With Cogenra Solar’s Next-Generation Dense Cell Interconnect PV Module Manufacturing Technology. This program is now very successfully building off of this work and commercializing the technology to enable increased solar adoption.« less

  5. Nanobubbles Form at Active Hydrophobic Spots on the Luminal Aspect of Blood Vessels: Consequences for Decompression Illness in Diving and Possible Implications for Autoimmune Disease-An Overview.

    PubMed

    Arieli, Ran

    2017-01-01

    Decompression illness (DCI) occurs following a reduction in ambient pressure. Decompression bubbles can expand and develop only from pre-existing gas micronuclei. The different hypotheses hitherto proposed regarding the nucleation and stabilization of gas micronuclei have never been validated. It is known that nanobubbles form spontaneously when a smooth hydrophobic surface is submerged in water containing dissolved gas. These nanobubbles may be the long sought-after gas micronuclei underlying decompression bubbles and DCI. We exposed hydrophobic and hydrophilic silicon wafers under water to hyperbaric pressure. After decompression, bubbles appeared on the hydrophobic but not the hydrophilic wafers. In a further series of experiments, we placed large ovine blood vessels in a cooled high pressure chamber at 1,000 kPa for about 20 h. Bubbles evolved at definite spots in all the types of blood vessels. These bubble-producing spots stained positive for lipids, and were henceforth termed "active hydrophobic spots" (AHS). The lung surfactant dipalmitoylphosphatidylcholine (DPPC), was found both in the plasma of the sheep and at the AHS. Bubbles detached from the blood vessel in pulsatile flow after reaching a mean diameter of ~1.0 mm. Bubble expansion was bi-phasic-a slow initiation phase which peaked 45 min after decompression, followed by fast diffusion-controlled growth. Many features of decompression from diving correlate with this finding of AHS on the blood vessels. (1) Variability between bubblers and non-bubblers. (2) An age-related effect and adaptation. (3) The increased risk of DCI on a second dive. (4) Symptoms of neurologic decompression sickness. (5) Preconditioning before a dive. (6) A bi-phasic mechanism of bubble expansion. (7) Increased bubble formation with depth. (8) Endothelial injury. (9) The presence of endothelial microparticles. Finally, constant contact between nanobubbles and plasma may result in distortion of proteins and their transformation into autoantigens.

  6. Nanobubbles Form at Active Hydrophobic Spots on the Luminal Aspect of Blood Vessels: Consequences for Decompression Illness in Diving and Possible Implications for Autoimmune Disease—An Overview

    PubMed Central

    Arieli, Ran

    2017-01-01

    Decompression illness (DCI) occurs following a reduction in ambient pressure. Decompression bubbles can expand and develop only from pre-existing gas micronuclei. The different hypotheses hitherto proposed regarding the nucleation and stabilization of gas micronuclei have never been validated. It is known that nanobubbles form spontaneously when a smooth hydrophobic surface is submerged in water containing dissolved gas. These nanobubbles may be the long sought-after gas micronuclei underlying decompression bubbles and DCI. We exposed hydrophobic and hydrophilic silicon wafers under water to hyperbaric pressure. After decompression, bubbles appeared on the hydrophobic but not the hydrophilic wafers. In a further series of experiments, we placed large ovine blood vessels in a cooled high pressure chamber at 1,000 kPa for about 20 h. Bubbles evolved at definite spots in all the types of blood vessels. These bubble-producing spots stained positive for lipids, and were henceforth termed “active hydrophobic spots” (AHS). The lung surfactant dipalmitoylphosphatidylcholine (DPPC), was found both in the plasma of the sheep and at the AHS. Bubbles detached from the blood vessel in pulsatile flow after reaching a mean diameter of ~1.0 mm. Bubble expansion was bi-phasic—a slow initiation phase which peaked 45 min after decompression, followed by fast diffusion-controlled growth. Many features of decompression from diving correlate with this finding of AHS on the blood vessels. (1) Variability between bubblers and non-bubblers. (2) An age-related effect and adaptation. (3) The increased risk of DCI on a second dive. (4) Symptoms of neurologic decompression sickness. (5) Preconditioning before a dive. (6) A bi-phasic mechanism of bubble expansion. (7) Increased bubble formation with depth. (8) Endothelial injury. (9) The presence of endothelial microparticles. Finally, constant contact between nanobubbles and plasma may result in distortion of proteins and their transformation into autoantigens. PMID:28861003

  7. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2015-09-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.

  8. Examining the Alignment of Subject Learning Outcomes and Course Curricula through Curriculum Mapping

    ERIC Educational Resources Information Center

    Lam, Bick-Har; Tsui, Kwok-Tung

    2013-01-01

    Content analysis has been used to conduct curriculum mapping to map the course objectives, course content, and the assessment tasks of 14 compulsory courses, onto the five Subject Learning Objective (SLO) factors of the Department of Curriculum and Instruction (DC&I) in a teacher education institution in Hong Kong. The results show that the…

  9. A Teaching Model for Scaffolding 4th Grade Students' Scientific Explanation Writing

    ERIC Educational Resources Information Center

    Yang, Hsiu-Ting; Wang, Kuo-Hua

    2014-01-01

    Improving students scientific explanations is one major goal of science education. Both writing activities and concept mapping are reported as effective strategies for enhancing student learning of science. The purpose of this study was to examine the effect of a teaching model, named the DCI model, which integrates a Descriptive explanation…

  10. 75 FR 38417 - Carbaryl; Order Denying Washington Toxics Coalition Petition to Revoke Tolerances and Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... uses on lawns and gardens, and indoors in kennels and on pet sleeping quarters. It was also registered...; cancellation of the following uses and application methods: all pet uses (dusts and liquids) except collars... carbaryl in pet collars, and environmental fate data. The product-specific DCI required acute toxicity and...

  11. Middle School Teacher Misconceptions and Anxieties Concerning Space Science Disciplinary Core Ideas in NGSS

    NASA Astrophysics Data System (ADS)

    Larsen, Kristine

    2017-01-01

    The Disciplinary Core Ideas (DCI) of the Next Generation Science Standards (NGSS) are grouped into the broad disciplinary areas of Physical Sciences, Life Sciences, Earth and Space Sciences, and Engineering, Technology and Application of Science, and feature learning progressions based on endpoint targets for each grade band. Since the Middle School DCIs build on the expected learning achievements to be reached by the end of Fifth Grade, and High School DCI similarly build on the expected learning achievements expected for the end of Eighth Grade, the Middle School grade band is of particular importance as the bridge between the Elementary and High School curriculum. In states where there is not a special Middle School Certification many of these science classes are taught by teachers prepared to teach at the Elementary level (and who may have limited content background). As a result, some pre-service and in-service teachers have expressed reduced self-confidence in both their own science content knowledge and their ability to apply it in the NGSS-based classroom, while decades of research has demonstrated the pervasiveness of science misconceptions among teachers. Thus the adoption of NGSS has the potential to drive talented teachers out of the profession who feel that they are ill-prepared for this sweeping transition. The key is providing rigorous education in both content and pedagogy for pre-service teachers and quality targeted professional development for in-service teachers. This report focuses on the Middle School Space Sciences grade band DCIs and presents research on specific difficulties, misconceptions and uncertainties with the material demonstrated by pre-service education students over the past four years in a required university science content course, as well as two year-long granted workshop series for current Middle School teachers. This information is relevant to the development of both new content courses aligned with NGSS for pre-service teachers and professional development for in-service teachers.

  12. Impact of thoracic surgery on esophageal motor function—Evaluation by high resolution manometry

    PubMed Central

    Kandulski, Arne; Malfertheiner, Peter; Riedel, Sandra; Zardo, Patrick; Hachenberg, Thomas; Schreiber, Jens

    2017-01-01

    Background Alteration of esophageal function is a potential risk factor for postoperative complications in thoracic surgery. This prospective study investigates esophageal motility and function during and after thoracic procedures via high resolution manometry (HRM) and impedance technology with spatiotemporal representation of pressure data. Methods Twelve consecutive patients eligible for elective thoracic surgery underwent preoperative and postoperative (48 hours and 7 days) esophageal HRM. Swallowing acts were carried out with 5 mL of water, 10 mL of water and 1 cm3 bread in physiological posture to evaluate distal contraction integral (DCI). Length and location of contractile integrity breaks were measured by investigators blinded to the form of surgical intervention. The impact of surgical procedures on esophageal motility was quantified according to current Chicago Classification (CC) criteria. Pre-, intra- and postoperative 24-hour multi-channel impedance pH–metry (MII-pH) was performed to further analyze gastroesophageal reflux patterns. Results All patients were investigated 48 hours prior to and 7 days after thoracic procedures, with a total of n=675 swallowing acts being included in our study. Increased motility patterns of the tubular esophagus occurred temporally 48 hours postoperatively. DCI 48 hours after surgery increased significantly (5 mL, P=0.049; solid, P=0.014) and returned to baseline values after seven days (5 mL, P=0.039; solid, P=0.039). Break length was significantly reduced 48 hours postoperatively, especially in the proximal esophageal segment (transition zone). Follow-up measurements after another week were comparable to preoperative baseline findings. The perioperative MII-pH measurement showed numerous artifacts caused by intubation and ventilation during surgery also with increasing short and frequent acidic reflux episodes. Conclusions Thoracic procedures cause a transient modulation of esophageal peristalsis with postoperative increased contractility of the tubular esophagus, presumably without affecting intraesophageal reflex arcs. Although limited by the number of patients, we can conclude on our data that postoperative esophageal hypomotility is unlikely to promote secondary pulmonary complications. PMID:28740669

  13. Impact of thoracic surgery on esophageal motor function-Evaluation by high resolution manometry.

    PubMed

    Wäsche, Anja; Kandulski, Arne; Malfertheiner, Peter; Riedel, Sandra; Zardo, Patrick; Hachenberg, Thomas; Schreiber, Jens

    2017-06-01

    Alteration of esophageal function is a potential risk factor for postoperative complications in thoracic surgery. This prospective study investigates esophageal motility and function during and after thoracic procedures via high resolution manometry (HRM) and impedance technology with spatiotemporal representation of pressure data. Twelve consecutive patients eligible for elective thoracic surgery underwent preoperative and postoperative (48 hours and 7 days) esophageal HRM. Swallowing acts were carried out with 5 mL of water, 10 mL of water and 1 cm 3 bread in physiological posture to evaluate distal contraction integral (DCI). Length and location of contractile integrity breaks were measured by investigators blinded to the form of surgical intervention. The impact of surgical procedures on esophageal motility was quantified according to current Chicago Classification (CC) criteria. Pre-, intra- and postoperative 24-hour multi-channel impedance pH-metry (MII-pH) was performed to further analyze gastroesophageal reflux patterns. All patients were investigated 48 hours prior to and 7 days after thoracic procedures, with a total of n=675 swallowing acts being included in our study. Increased motility patterns of the tubular esophagus occurred temporally 48 hours postoperatively. DCI 48 hours after surgery increased significantly (5 mL, P=0.049; solid, P=0.014) and returned to baseline values after seven days (5 mL, P=0.039; solid, P=0.039). Break length was significantly reduced 48 hours postoperatively, especially in the proximal esophageal segment (transition zone). Follow-up measurements after another week were comparable to preoperative baseline findings. The perioperative MII-pH measurement showed numerous artifacts caused by intubation and ventilation during surgery also with increasing short and frequent acidic reflux episodes. Thoracic procedures cause a transient modulation of esophageal peristalsis with postoperative increased contractility of the tubular esophagus, presumably without affecting intraesophageal reflex arcs. Although limited by the number of patients, we can conclude on our data that postoperative esophageal hypomotility is unlikely to promote secondary pulmonary complications.

  14. Enhancing the European Union’s Development Strategy in Afghanistan

    DTIC Science & Technology

    2010-06-01

    REE Rare Earth Element SCA Swedish Committee for Afghanistan SIDA Swedish International Development Cooperation Agency SIGAR Special Inspector...member states such as Ireland’s Development Cooperation Ireland (DCI), Sweden’s Swedish International Development Cooperation Agency ( SIDA ), and the...Command and General Staff College, June 2008.) 71. 142 Swedish International Development Cooperation Agency, “Afghanistan Sida Country Report 2005

  15. Traditional plants used for the treatment of diabetes mellitus in Sursagar constituency, Jodhpur, Rajasthan - An ethnomedicinal survey.

    PubMed

    Goyal, Manoj

    2015-11-04

    In Jodhpur, large number of people suffering with non-insulin dependent diabetes mellitus (type 2 diabetes). They are using medicinal plants along with modern medicine for the management of diabetes. The aim of this work is to document the anti-diabetic plants and determine the most relevant anti-diabetic plant species using the Disease Consensus Index. Ethnomedicinal survey was conducted for selection of anti-diabetic plant. Structured questionnaire was developed for calculation of Disease Consensus Index and administered to fifty Type 2 diabetic patients for recording their response. Twenty-one species of anti-diabetic plants were recorded, Momordica charantia (score: 0.71), Azadirachta indica (score: 0.64), Trigonella foenum-graecum (score: 0.63), Capparis decidua (score: 0.60), Withania coagulans (score: 0.54), Gymnema sylvestre (score: 0.52) and Syzygium cumini (score: 0.51) were the most significant anti-diabetic plants of the area of study, having DCI more than 0.5. Use of anti-diabetic plants is prevalent diabetic patients of the area. C. decidua, W. coagulans and G. sylvestre are recommend the further phytochemical and pharmacological investigation due to high DCI score and relatively unexplored status. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Field validation of Tasmania's aquaculture industry bounce-diving schedules using Doppler analysis of decompression stress.

    PubMed

    Smart, David R; Van den Broek, Cory; Nishi, Ron; Cooper, P David; Eastman, David

    2014-09-01

    Tasmania's aquaculture industry produces over 40,000 tonnes of fish annually, valued at over AUD500M. Aquaculture divers perform repetitive, short-duration bounce dives in fish pens to depths up to 21 metres' sea water (msw). Past high levels of decompression illness (DCI) may have resulted from these 'yo-yo' dives. This study aimed to assess working divers, using Doppler ultrasonic bubble detection, to determine if yo-yo diving was a risk factor for DCI, determine dive profiles with acceptable risk and investigate productivity improvement. Field data were collected from working divers during bounce diving at marine farms near Hobart, Australia. Ascent rates were less than 18 m·min⁻¹, with routine safety stops (3 min at 3 msw) during the final ascent. The Kisman-Masurel method was used to grade bubbling post dive as a means of assessing decompression stress. In accordance with Defence Research and Development Canada Toronto practice, dives were rejected as excessive risk if more than 50% of scores were over Grade 2. From 2002 to 2008, Doppler data were collected from 150 bounce-dive series (55 divers, 1,110 bounces). Three series of bounce profiles, characterized by in-water times, were validated: 13-15 msw, 10 bounces inside 75 min; 16-18 msw, six bounces inside 50 min; and 19-21 msw, four bounces inside 35 min. All had median bubble grades of 0. Further evaluation validated two successive series of bounces. Bubble grades were consistent with low-stress dive profiles. Bubble grades did not correlate with the number of bounces, but did correlate with ascent rate and in-water time. These data suggest bounce diving was not a major factor causing DCI in Tasmanian aquaculture divers. Analysis of field data has improved industry productivity by increasing the permissible number of bounces, compared to earlier empirically-derived tables, without compromising safety. The recommended Tasmanian Bounce Diving Tables provide guidance for bounce diving to a depth of 21 msw, and two successive bounce dive series in a day's diving.

  17. Traditional management of diabetes in Pakistan: Ethnobotanical investigation from Traditional Health Practitioners.

    PubMed

    Yaseen, Ghulam; Ahmad, Mushtaq; Zafar, Muhammad; Sultana, Shazia; Kayani, Sadaf; Cetto, Adolfo Andrade; Shaheen, Shabnum

    2015-11-04

    The uses of anti-diabetic plants are well anchored in the traditional health care system of Pakistan. To the best of our knowledge, this is the first ethno-botanical study about the uses of plants for the treatment of diabetes. The aim of the study is to record indigenous knowledge on anti-diabetic plants from Traditional Health Practitioners (THPs) and diabetic patients. In addition, it is aimed to ascertain and validate the traditional uses of anti-diabetic plants by citing pharmacological activities and phytochemical constitutes from previously published literature. The ethno-medicinal data was documented during 14 field surveys, each comprising of 10 days, from 3 regions of Pakistan (Islamabad, Khyber Pukhtoonkhwa and Deserts of Sindh). In total, 113 THPs and 44 diabetic patients were interviewed using open-ended and semi-structured questionnaires. Quantitative indices, including Relative Frequency of Citation percentage (RFC %) and Disease Consensus Index (DCI) were calculated. The documented data is authenticated by comparing with 28 published articles on ethno-botanical aspects and many pharmacological studies. In total, 120 plant species belonging to 50 families were reported. The ethno-botanical results indicated that Moraceae (11 species); herb (56 reports) is dominant life form; the leaves (56 reports) are the most used plant part and decoction (24%) is the preferred mode of preparation. The quantitative analysis shows that RFC% ranges from 14 to 42 and DCI varies from 0.15 to 0.74. By comparing to previous studies, 64 species are reported new in traditional treatment of DM; 40 species are new to pharmacological evidence and 3 species are new to phytochemical studies. This study recoded the significant indigenous knowledge about anti-diabetic plants among the THPs and diabetic patients in Pakistan. This type of ethno-botanical knowledge on traditional use of anti-diabetic plants is an important step in designing detailed pharmacological and clinical trials for Diabetes Miletus treatment. It is recommended that further pharmacological and phytochemical analysis should be conducted on those species which lack previous references in literature and have highest Frequency of Citation (FC), Disease Consensus Index (DCI) and Relative Frequency of Citation percentage (RFC%). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Cerebral Taurine Levels are Associated with Brain Edema and Delayed Cerebral Infarction in Patients with Aneurysmal Subarachnoid Hemorrhage.

    PubMed

    Kofler, Mario; Schiefecker, Alois; Ferger, Boris; Beer, Ronny; Sohm, Florian; Broessner, Gregor; Hackl, Werner; Rhomberg, Paul; Lackner, Peter; Pfausler, Bettina; Thomé, Claudius; Schmutzhard, Erich; Helbok, Raimund

    2015-12-01

    Cerebral edema and delayed cerebral infarction (DCI) are common complications after aneurysmal subarachnoid hemorrhage (aSAH) and associated with poor functional outcome. Experimental data suggest that the amino acid taurine is released into the brain extracellular space secondary to cytotoxic edema and brain tissue hypoxia, and therefore may serve as a biomarker for secondary brain injury after aSAH. On the other hand, neuroprotective mechanisms of taurine treatment have been described in the experimental setting. We analyzed cerebral taurine levels using high-performance liquid chromatography in the brain extracellular fluid of 25 consecutive aSAH patients with multimodal neuromonitoring including cerebral microdialysis (CMD). Patient characteristics and clinical course were prospectively recorded. Associations with CMD-taurine levels were analyzed using generalized estimating equations with an autoregressive process to handle repeated observations within subjects. CMD-taurine levels were highest in the first days after aSAH (11.2 ± 3.2 µM/l) and significantly decreased over time (p < 0.001). Patients with brain edema on admission or during hospitalization (N = 20; 80 %) and patients developing DCI (N = 5; 20 %) had higher brain extracellular taurine levels compared to those without (Wald = 7.3, df = 1, p < 0.01; Wald = 10.1, df = 1, p = 0.001, respectively) even after adjusting for disease severity and CMD-probe location. There was no correlation between parenteral taurine supplementation and brain extracellular taurine (p = 0.6). Moreover, a significant correlation with brain extracellular glutamate (r = 0.82, p < 0.001), lactate (r = 0.56, p < 0.02), pyruvate (r = 0.39, p < 0.01), potassium (r = 0.37, p = 0.01), and lactate-to-pyruvate ratio (r = 0.24, p = 0.02) was found. Significantly higher CMD-taurine levels were found in patients with brain edema or DCI after aneurysmal subarachnoid hemorrhage. Its value as a potential biomarker deserves further investigation.

  19. Director of National Intelligence: Another Bureaucratic Layer or an Effective Office?

    DTIC Science & Technology

    2006-12-15

    created the Director of Central Intelligence (DCI). After the dissolution of COI, its various intelligence functions were divided between the State...demands of these two full time jobs on the time and attention of any person, no matter how skilled in management, are overwhelming . . . Even if one...The literature review is divided by the intelligence subjects of analysis, policy, and reform.. 1Michael Lee Lanning, Senseless Secrets: The

  20. AGOR 28

    DTIC Science & Technology

    2015-04-23

    to work on initial outfitting lists for Sally Ride. ii. Working on NS5 Hierarchy 4. Operator Concerns: • Tuff-Mass MLV and Acoustic Tiles...The yard is continuing to install the Quad-zero MLV in various locations throughout Sally Ride. DCI is holding off on installing any new insulation ...in location with no sound dampening tiles. This includes the Main Engine Space overhead and aft bulkhead as well as the MCS. The Quad-Zeros is not

  1. Studies in Intelligence. Volume 58, Number 1, March 2014

    DTIC Science & Technology

    2014-03-01

    contact for defense intelli- gence, more effective implementa- tion of DCI policy guidance, consolidated oversight of DoD pro - grams and improved...disparate parts of the budget. As USD(I) Clapper went even fur- ther in exercising MIP authorities and developing an intelligence pro - gram between...the MIP and the broader National Intelligence Pro - gram (NIP), making defense intelli- gence program planning more effective and efficient. Over time

  2. AGOR 28

    DTIC Science & Technology

    2014-11-06

    Foc’sle Deck. Associated wiring, hvac and plumbing also going in. Minimal joiner work on other decks and pilot house. 6. Call-outs...TEST PROCEDURES ( MCCS Design Verification Test Procedure)(R/ASR) 173/0 AGOR27 A002 STD Report - DESIGN REVIEW AGENDAS AND MINUTES ( DR #17 DCI... HVAC Book 1 of 3)(DARC REV) 340/1 AGOR27 A055 TM Report - COMMERCIAL TECHNICAL MANUALS AND SUPPLEMENTAL DATA ( 512 Wilhelmsen HVAC Book 2 of 3

  3. Possible Role of Inflammation and Galectin-3 in Brain Injury after Subarachnoid Hemorrhage

    PubMed Central

    2018-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) is known as one of the most devastating diseases in the central nervous system. In the past few decades, research on SAH has focused on cerebral vasospasm to prevent post-SAH delayed cerebral ischemia (DCI) and to improve outcomes. However, increasing evidence has suggested that early brain injury (EBI) is an important mechanism contributing to DCI, cerebral vasospasm as well as poor outcomes. Though the mechanism of EBI is very complex, inflammation is thought to play a pivotal role in EBI. Galectin-3 is a unique chimera type in the galectin family characterized by its β-galactoside-binding lectin, which mediates various pathologies, such as fibrosis, cell adhesion, and inflammation. Recently, two clinical studies revealed galectin-3 to be a possible prognostic biomarker in SAH patients. In addition, our recent report suggested that higher acute-stage plasma galectin-3 levels correlated with subsequent development of delayed cerebral infarction that was not associated with vasospasm in SAH patients. We review the possible role and molecular mechanisms of inflammation as well as galectin-3 in brain injuries, especially focusing on EBI after SAH, and discuss galectin-3 as a potential new therapeutic or research target in post-SAH brain injuries. PMID:29414883

  4. Intracranial Biodegradable Silica-Based Nimodipine Drug Release Implant for Treating Vasospasm in Subarachnoid Hemorrhage in an Experimental Healthy Pig and Dog Model

    PubMed Central

    Koskimäki, Janne; Tarkia, Miikka; Ahtola-Sätilä, Tuula; Saloranta, Lasse; Laakso, Aki; Frantzén, Janek

    2015-01-01

    Nimodipine is a widely used medication for treating delayed cerebral ischemia (DCI) after subarachnoid hemorrhage. When administrated orally or intravenously, systemic hypotension is an undesirable side effect. Intracranial subarachnoid delivery of nimodipine during aneurysm clipping may be more efficient way of preventing vasospasm and DCI due to higher concentration of nimodipine in cerebrospinal fluid (CSF). The risk of systemic hypotension may also be decreased with intracranial delivery. We used animal models to evaluate the feasibility of surgically implanting a silica-based nimodipine releasing implant into the subarachnoid space through a frontotemporal craniotomy. Concentrations of released nimodipine were measured from plasma samples and CSF samples. Implant degradation was followed using CT imaging. After completing the recovery period, full histological examination was performed on the brain and meninges. The in vitro characteristics of the implant were determined. Our results show that the biodegradable silica-based implant can be used for an intracranial drug delivery system and no major histopathological foreign body reactions were observed. CT imaging is a feasible method for determining the degradation of silica implants in vivo. The sustained release profiles of nimodipine in CSF were achieved. Compared to a traditional treatment, higher nimodipine CSF/plasma ratios can be obtained with the implant. PMID:25685803

  5. Development of underwater and hyperbaric medicine in Malaysia.

    PubMed

    Rozali, A; Rampal, K G; Zin, B Mohd; Sherina, M S; Khairuddin, H; Abd Halim, M; Sulaiman, A

    2006-12-01

    Underwater and Hyperbaric Medicine is a treatment modality gaining recognition in Malaysia. It uses the hyperbaric oxygen therapy (HBOT) approach where patients are placed in recompression chambers and subjected to oxygen therapy under pressure. In Malaysia it was introduced as early as the 1960's by the Royal Malaysian Navy to treat their divers for decompression illness (DCI), arterial gas embolism (AGE) and barotraumas. Other sectors in the armed forces, universities and private health centres began developing this approach too in the late 1990's, for similar purposes. In 1996, Underwater and Hyperbaric Medicine began gaining its popularity when the Institute of Underwater and Hyperbaric Medicine at the Armed Forces Hospital in Lumut started treating specific clinical diseases such as diabetic foot ulcers, osteomyelitis, and carbon monoxide poisoning and other diseases using HBOT. This paper discusses the development of this interesting treatment modality, giving a brief historical overview to its current development, as well as provides some thought for its future development in Malaysia.

  6. The Portfolio Approach Developed to Underpin the Capital Investment Program Plan Review (CIPPR)

    DTIC Science & Technology

    2014-11-06

    Basinger, Director, DCI, CFD Scientific Letter The PORTFOLIO APPROACH developed to underpin the Capital Investment Program Plan Review (CIPPR) To better...prepare senior management for meetings about CIPPR in November 2014, this scientific letter has been pre- pared upon request [1] to clarify some of...Research and Analysis in support of CIPPR was to: 1. Provide scientific support to the development of a traceable and sustainable approach and process by

  7. The Portfolio Creation Model Developed for the Capital Investment Program Plan Review (CIPPR)

    DTIC Science & Technology

    2014-11-12

    Basinger, Director, DCI, CFD Scientific Letter The PORTFOLIO CREATION MODEL developed for the Capital Investment Program Plan Review (CIPPR) To inform...senior management about CIPPR decision support, this scientific letter has been prepared upon request [1] to clarify some of the key concepts about...delivery process as laid out in the Defence Project Approval Directive (PAD). 1 With respect to the list above, the subject of this scientific letter is

  8. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2015-08-10

    government and SIO were started. Marine Outfitting has started working on a schedule. • Acoustic Tiles & MLV – Yard continues to apply Delta DT...direct the sound away from the main deck working area. NCE will be here to recheck the level during the underway portion of the PSTP next week on...ABS Correspondence - Self-Extinguishing Insulation )(R/ASR) 116/2 AGOR27 A024 STD Report - REGULATORY BODY CORRESPONDENCE ( DCI/USCG - ACCU, QFA

  9. Clinical Investigation Program. Annual Progress Report. Volume 1

    DTIC Science & Technology

    1994-01-20

    Suport Labs Resch Chemist 13 0644 GS Salata, KF Allergy Microbiologist 12 0403 CS Billups, L Flow Cytom Microbiologist 12 0403 GS Dobek, AS Inf Disease 5...continued to increase laboratory research support to principal investigators throughout the medical center. The DCI Flow Cytometry Laboratory provided...Kalman PhD. Mitogen-Inducible T Suppressor Cell 12 Assay by Flow Cytometry (12/89) * Reference is to page number(s) in Volume II. 30 PROTOCOL NUMBER

  10. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2015-01-29

    Crane FAT at Sherwood, OR iii. Design Review at Anacortes 2. The following Shipyard Question Submittals were reviewed and commented on: No...two 100-kw chill water heaters for HVAC winter operation. New for this reporting period – DCI is installing the hardware (cables and shut trips) to...the two 100-kw HVAC heaters and the galley equipment breakers. • Main Crane Towing & Coring Crutch – The crutch assembly being provided by Allied

  11. MR Angiography Follow-Up 10 Years after Cryptogenic Nonperimesencephalic Subarachnoid Hemorrhage

    PubMed Central

    Wenz, Holger; Wenz, Ralf; al Mahdi, Mohamad-Motaz; Scharf, Johann; Groden, Christoph; Schmiedek, Peter; Seiz-Rosenhagen, Marcel

    2015-01-01

    Objectives Long-term magnetic resonance angiography (MRA) follow-up studies regarding cryptogenic nonperimesencephalic subarachnoid hemorrhage (nSAH) are scarce. This single-centre study identified all patients with angiographically verified cryptogenic nSAH from 1998 to 2007: The two main objectives were to prospectively assess the incidence of de novo aneurysm with 3.0-MRI years after cryptogenic nSAH in patients without evidence for further hemorrhage, and retrospectively assess patient demographics and outcome. Methods From prospectively maintained report databases all patients with angiographically verified cryptogenic nSAH were identified. 21 of 29 patients received high-resolution 3T-MRI including time-of-flight and contrast-enhanced angiography, 10.2 ± 2.8 years after cryptogenic nSAH. MRA follow-up imaging was compared with initial digital subtraction angiography (DSA) and CT/MRA. Post-hemorrhage images were related to current MRI with reference to persistent lesions resulting from delayed cerebral ischemia (DCI) and post-hemorrhagic siderosis. Patient-based objectives were retrospectively abstracted from clinical databases. Results 29 patients were identified with cryptogenic nSAH, 17 (59%) were male. Mean age at time of hemorrhage was 52.9 ± 14.4 years (range 4 – 74 years). 21 persons were available for long-term follow-up. In these, there were 213.5 person years of MRI-follow-up. No de novo aneurysm was detected. Mean modified Rankin Scale (mRS) during discharge was 1.28. Post-hemorrhage radiographic vasospasm was found in three patients (10.3%); DCI-related lesions occurred in one patient (3.4%). Five patients (17.2%) needed temporary external ventricular drainage; long-term CSF shunt dependency was necessary only in one patient (3.4%). Initial DSA retrospectively showed a 2 x 2 mm aneurysm of the right distal ICA in one patient, which remained stable. Post-hemorrhage siderosis was detected 8.1 years after the initial bleeding in one patient (4.8%). Conclusion Patients with cryptogenic nSAH have favourable outcomes and do not exhibit higher risks for de novo aneurysms. Therefore the need for long-term follow up after cryptogenic nSAH is questionable. PMID:25688554

  12. Annual Progress Report FY-92. Volume 1

    DTIC Science & Technology

    1993-01-21

    Billups, L Flow Cytom Resh Psychologist 12 0180 CS Hamm, C DCI 7 DESCRIPTION GRADE MOS BRANCH NAME ACTIVITY Kyle Metabolic Unit Nursing Service Supv...3349 Salata, Kalman PhD. Mitogen-Inducible T Suppressor Cell 13 Assay by Flow Cytometry (12/89) 3350 Salata, Kalman PhD. Flow Cytometric Analysis of...17 Immunotherapy (3/90) 3354 Salata, Kalman PhD. Two Way Mixed Lymphocyte Culture: 18 Analysis by Two Color Flow Cytometry (4/90) 3355 Salata, Kalman

  13. China and Proliferation of Weapons of Mass Destruction and Missiles: Policy Issues

    DTIC Science & Technology

    2006-12-11

    Ghauri (Hatf-5) medium-range ballistic missile (MRBM), which is based on the North Korean No Dong missile. U.S. intelligence was said to suspect that...confirming these stories, the DCI reported in August 2000 that, besides North Korean help, PRC entities provided “increased assistance” to Pakistan’s...ranges, respectively, of about 800 mi. and 1,250 mi.). Over 100 PRC and North Korean experts worked there, reported the Washington Times (November 23

  14. Morphology and Distribution of the Acanthoecidae (Choanoflagellata) from the Weddell Sea during the Austral Summer, 1977,

    DTIC Science & Technology

    1980-07-01

    jun our onivof he ( inhou, iavall ddrsse tonalof(e( i’(e. vol 17,1p 14121lliin~ ict lii’Ac itlci ’ dci’, ,ll ~ddmcssed iiiihhird, 1) 1 (1976) the U...Ili(] postir t.t piI4 wit, ’itim 25-35 gym . Number of longitudinal (ostae 12, pill Habitat. the sea In tile. 1( 11111 i. lit-.1t each composed of 9 or

  15. The Dominance Concept Inventory: A Tool for Assessing Undergraduate Student Alternative Conceptions about Dominance in Mendelian and Population Genetics

    PubMed Central

    Perez, Kathryn E.; Price, Rebecca M.

    2014-01-01

    Despite the impact of genetics on daily life, biology undergraduates understand some key genetics concepts poorly. One concept requiring attention is dominance, which many students understand as a fixed property of an allele or trait and regularly conflate with frequency in a population or selective advantage. We present the Dominance Concept Inventory (DCI), an instrument to gather data on selected alternative conceptions about dominance. During development of the 16-item test, we used expert surveys (n = 12), student interviews (n = 42), and field tests (n = 1763) from introductory and advanced biology undergraduates at public and private, majority- and minority-serving, 2- and 4-yr institutions in the United States. In the final field test across all subject populations (n = 709), item difficulty ranged from 0.08 to 0.84 (0.51 ± 0.049 SEM), while item discrimination ranged from 0.11 to 0.82 (0.50 ± 0.048 SEM). Internal reliability (Cronbach's alpha) was 0.77, while test–retest reliability values were 0.74 (product moment correlation) and 0.77 (intraclass correlation). The prevalence of alternative conceptions in the field tests shows that introductory and advanced students retain confusion about dominance after instruction. All measures support the DCI as a useful instrument for measuring undergraduate biology student understanding and alternative conceptions about dominance. PMID:26086665

  16. A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography.

    PubMed

    Berg, Eric; Roncali, Emilie; Kapusta, Maciej; Du, Junwei; Cherry, Simon R

    2016-02-01

    In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3-3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%-7% with phosphor-coated crystals compared to uncoated crystals. These results demonstrate the feasibility of obtaining TOF-DOI capabilities with simple block detector readout using phosphor-coated crystals.

  17. Microenvironmental Regulation of Chemokine (C-X-C-motif) Receptor 4 in Ovarian Carcinoma

    PubMed Central

    Barbolina, Maria V.; Kim, Mijung; Liu, Yueying; Shepard, Jaclyn; Belmadani, Abdelhak; Miller, Richard J.; Shea, Lonnie D.; Stack, M. Sharon

    2010-01-01

    The majority of women diagnosed with epithelial ovarian carcinoma (EOC) succumb due to complications of metastatic disease, suggesting that anti-metastatic therapies may improve patient survival. EOC metastasis involves intra-peritoneal shedding of cells from the primary tumor, followed by adhesion and localized penetration of the submesothelial matrix to anchor metastatic implants. Accumulation of malignant ascites is also common. Thus, a unique microenvironmental niche is established, which includes malignant cells and a plethora of soluble factors secreted by – or in response to – tumor cells. As cells penetrating the sub-mesothelial surface encounter an interstitial collagen-rich ECM, we have used 3-dimensional type I collagen (3DCI) gels to model early events resulting from intra-peritoneal anchoring. In this study we demonstrate a novel pathway of CXCR4 upregulation through β1-integrin- and NFκB- dependent signaling pathways in response to 3DCI. We also demonstrate the involvement of CXCR4-SDF1 axis in collagen invasion and proliferation, relevant to the metastatic EOC. Our data show that CXCR4 expression in human EOCs, as well as SDF1 presence in the ascites, is correlated with disease progression and metastasis. These data emphasize the importance of CXCR4 – SDF1 axis in EOC metastasis and suggest that this mechanism should be accounted for when targeting EOC metastasis. PMID:20460402

  18. Studies of beam injection with a compensated bump and uncompensated bump in a synchrotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akbar Fakhri, Ali; Prajapati, S. K.; Ghodke, A. D.

    2013-08-15

    Synchrotron radiation sources Indus-1 and Indus-2 have a synchrotron as the common injector. A three kicker compensated bump injection scheme was employed for beam injection into this synchrotron. The stored beam current in the synchrotron is higher, when all the three kickers are operated at the same current than when kickers are operated at currents required to generate compensated bump. Beam dynamics studies have been done to understand why this happens. Theoretical studies indicate that higher stored current in the later case is attributed to smaller residual oscillations of injected beam. These studies also reveal that if the angle ofmore » the injected beam during beam injection is kept varying, the performance could be further improved. This is experimentally confirmed by injecting the beam on rising part of the injection septum magnet current pulse.« less

  19. NASA personnel in a control room during the successful second flight of the X-43A aircraft

    NASA Image and Video Library

    2004-03-27

    NASA personnel in a control room during the successful second flight of the X-43A aircraft. front row, left to right: Randy Voland, LaRC Propulsion; Craig Christy, Boeing Systems; Dave Reubush, NASA Hyper-X Deputy Program Manager; and Vince Rausch, NASA Hyper-X Program Manager. back row, left to right: Bill Talley, DCI/consultant; Pat Stoliker, DFRC Director (Acting) of Research Engineering; John Martin, LaRC G&C; and Dave Bose, AMA/Controls.

  20. Medical Research: A Bibliography of Walter Reed Army Medical Center Staff Publications, 1986-1989. Volume 1

    DTIC Science & Technology

    1990-01-01

    Wilson PD Jr: Fracture of the femoral component. Analysis of failure and long-term follow-up of rev-ision. Orthop Chin North Am 1988 Jul;19(3):637-47...DMED,DCI 88224857 Dysart SH, Savory CG, Callaghan JJ: Nonoperative treatment of a postoperative fracture around an uncemented porous-coated femoral...trochanter fractures of the hip without intertrochanteric extension: a case report. Milit Med 1988 Aug;153(8):421-3. DSURG 89015096 Lucente FE, Patow

  1. Regulation of BRCA1 Function by DNA Damage-Induced Site-Specific Phosphorylation

    DTIC Science & Technology

    2005-06-01

    Nature 382, 678-679. 8. Haile , D.T., and Parvin, J.D. (1999). Activation of transcription in vitro by the BRCAI Carboxyl-terminal domain. J. Biol. Chem...for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s) and should not be...construed as an official Department of the Army position, policy or decision unless so designated by other documentation. 20051101 125 REPOR DCI P Form

  2. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2015-05-08

    work on initial outfitting lists for Sally Ride. ii. Working on NS5 Hierarchy 4. Operator Concerns: • Tuff-Mass MLV and Acoustic Tiles – The...yard is continuing to install the Quad-zero MLV in various locations throughout Sally Ride. DCI is holding off on installing any new insulation in...Traction Winch Rm fwd bulkhead tiles • Sally Ride Quad-Zero MLV – The yard continues to install the Quad-Zero in location with no sound dampening tiles

  3. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2015-07-30

    sides of the lower engine room still have sections of bare acoustic tile that require thermal insulation and Quad-Zero • Main Deck Noise Levels, Sally...for Sally Ride. ii. Working on NS5 Hierarchy 4. Operator Concerns: • Acoustic Tiles & MLV – No additional tiles have been removed this...reporting period. DCI has no plans to remove any more per USCG. No indication as to what sound treatment will be placed in the engine room bilge or on

  4. China and Proliferation of Weapons of Mass Destruction and Missiles: Policy Issues

    DTIC Science & Technology

    2007-05-09

    medium-range ballistic missile (MRBM), which is based on the North Korean No Dong missile. U.S. intelligence was said to suspect that China Poly Ventures...stories, the DCI reported in August 2000 that, besides North Korean help, PRC entities provided “increased assistance” to Pakistan’s ballistic missile...development of the Shahab-3 and Shahab-4 MRBMs (with ranges, respectively, of about 800 mi. and 1,250 mi.). Over 100 PRC and North Korean experts worked there

  5. Manual for Calculating the Seepage Strength of Earthfill Dams,

    DTIC Science & Technology

    1976-07-01

    gravity of material of soil particles; d--diameter of soil particles; dio...d 17 ...dsr-diameters of soil particles, the smallest of which in its...compcsition may be present as 10... 17 ...60% by weight; dci--diameter of (piping) particles of soil which may be carried away by the seepage flow; -dso Y1 d...should, however, be reduced, assuming: k" onnfrmsi S(Jk)dnonuniform soil = [(Jk)d]uniform soil ( 17 ) where 7is the coefficient of reduction (less than

  6. Operating Policies for Non- stationary Two-Echelon Inventory Systems for Reparable Items.

    DTIC Science & Technology

    1986-05-01

    resupply policy. Even under an HCP, we might want to change the resupply policy at management igtervention times to reflect what we predict will happen...management is concerned with the worst performance predicted during the horizon. Regardless of the average performance over the horizon, management may not...locations in DCi(tm-ll tm ) and INi(tm-l tm) . Case 3 a: ASi(tm I ) > ASi(tm); INi(tm- lstm ) empty. Disposals must be made to lover the asset positions

  7. Top-Off Injection and Higher Currents at the Stanford Synchrotron Radiation Lightsource

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Johannes M.; Liu, James C.; Prinz, Alyssa A.

    2011-04-05

    The Stanford Synchrotron Radiation Lightsource (SSRL) at the SLAC National Accelerator Laboratory is a 234 m circumference storage ring for 3 GeV electrons with its synchrotron radiation serving currently 13 beamlines with about 27 experimental stations. It operated for long time with 100 mA peak current provided by usually three injections per day. In July 2009, the maximum beam current was raised to 200 mA. Over the period from June 2009 to March 2010, Top-Off operation started at every beamline. Top-Off, i.e., the injection of electrons into the storage ring with injection stoppers open, is necessary for SSRL to reachmore » its design current of 500 mA. In the future, the maximal power of the injection current will also soon be raised from currently 1.5 W to 5 W. The Radiation Protection Department at SLAC worked with SSRL on the specifications for the safety systems for operation with Top-Off injection and higher beam currents.« less

  8. Do large hiatal hernias affect esophageal peristalsis?

    PubMed Central

    Roman, Sabine; Kahrilas, Peter J; Kia, Leila; Luger, Daniel; Soper, Nathaniel; Pandolfino, John E

    2013-01-01

    Background & Aim Large hiatal hernias can be associated with a shortened or tortuous esophagus. We hypothesized that these anatomic changes may alter esophageal pressure topography (EPT) measurements made during high-resolution manometry (HRM). Our aim was to compare EPT measures of esophageal motility in patients with large hiatal hernias to those of patients without hernia. Methods Among 2000 consecutive clinical EPT, we identified 90 patients with large (>5 cm) hiatal hernias on endoscopy and at least 7 evaluable swallows on EPT. Within the same database a control group without hernia was selected. EPT was analyzed for lower esophageal sphincter (LES) pressure, Distal Contractile Integral (DCI), contraction amplitude, Contractile Front Velocity (CFV) and Distal Latency time (DL). Esophageal length was measured on EPT from the distal border of upper esophageal sphincter to the proximal border of the LES. EPT diagnosis was based on the Chicago Classification. Results The manometry catheter was coiled in the hernia and did not traverse the crural diaphragm in 44 patients (49%) with large hernia. Patients with large hernias had lower average LES pressures, lower DCI, slower CFV and shorter DL than patients without hernia. They also exhibited a shorter mean esophageal length. However, the distribution of peristaltic abnormalities was not different in patients with and without large hernia. Conclusions Patients with large hernias had an alteration of EPT measurements as a consequence of the associated shortened esophagus. However, the distribution of peristaltic disorders was unaffected by the presence of hernia. PMID:22508779

  9. A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

    PubMed Central

    Berg, Eric; Roncali, Emilie; Kapusta, Maciej; Du, Junwei; Cherry, Simon R.

    2016-01-01

    Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals. PMID:26843254

  10. A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, Eric, E-mail: eberg@ucdavis.edu; Roncali, Emilie; Du, Junwei

    Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI providedmore » the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.« less

  11. Profiling of the injected charge drift current transients by cross-sectional scanning technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaubas, E., E-mail: eugenijus.gaubas@ff.vu.lt; Ceponis, T.; Pavlov, J.

    2014-02-07

    The electric field distribution and charge drift currents in Si particle detectors are analyzed. Profiling of the injected charge drift current transients has been implemented by varying charge injection position within a cross-sectional boundary of the particle detector. The obtained profiles of the induction current density and duration of the injected charge drift pulses fit well the simulated current variations. Induction current transients have been interpreted by different stages of the bipolar and monopolar drift of the injected carriers. Profiles of the injected charge current transients registered in the non-irradiated and neutron irradiated Si diodes are compared. It has beenmore » shown that the mixed regime of the competing processes of drift, recombination, and diffusion appears in the measured current profiles on the irradiated samples. The impact of the avalanche effects can be ignored based on the investigations presented. It has been shown that even a simplified dynamic model enabled us to reproduce the main features of the profiled transients of induced charge drift current.« less

  12. Ethnomedicinal uses of plants in the treatment of paediatric geohelminth infections in Kalat district of Northern Balochistan, Pakistan.

    PubMed

    Bibi, Tahira; Ahmad, Mushtaq; Edwards, Sarah E; Tareen, Niaz Mohammad; Jabeen, Rukhsana; Abdullah, Irum

    2016-05-13

    Infection by intestinal parasitic worms (soil-transmitted helminths or geohelminths) is prevalent in many parts of the world, and poses a particular health risk to children. This paper presents findings from a preliminary study with the primary aim to document indigenous knowledge about the use of herbal medicines in the treatment of intestinal worm infections in children among the local communities of Kalat district of northern Balochistan, Pakistan. Ethnomedicinal data were collected through a triangulation approach, that included participant-observation and rapid appraisal methods. Prior-informed consent (PIC) was obtained from participants before conducting structured and semi-structured interviews and delivering an open ended questionnaire. A total of 94 participants, including 28 men (of whom 7 were traditional healers), and 66 women of four different age groups were interviewed. Results were analyzed using quantitative indices of Use Value citations (UVC) and Disease-Consensus Index (DCI). Fewer men than women agreed to be interviewed, thus overall women in the area appeared to have more ethnomedicinal knowledge. The majority of study participants belonged to the older age group (>55 years). A total of 49 plant species, belonging to 47 genera, distributed in 30 families were reported. The families Asteraceae and Lamiaceae were most frequently represented, with four species each. Trees were the most common life form, with seeds the most frequently cited plant part used (29%). Nearly a third (31%) of plant-based remedies reported in the treatment of intestinal worms were administered as a decoction. The highest UVC and DCI was reported for the species Ferula assa-foetida sL. (UVC 0.51, DCI 0.46). This study provides previously unreported data on the use of medicinal plants in the treatment of geohelminth infections in children of Kalat. Eight species, Acacia modesta Wall., Asparagus capitatus Baker, Microcephala lamellata (Bunge) Pobed., Nepeta praetervisa Rech.f., Plantago ciliata Desf., Pistacia atlantica Desf., Seriphidium quettense (Podlech) Y.R.Ling and Thymus linearis Benth. are reported here as anthelmintics for the first time. Detailed studies on the anthelmintic activity of chemical constituents of these species are lacking from existing literature. Further phytochemical, pharmacological and toxicity studies are required in order to evaluate the efficacy and safety of these newly reported anthelmintic species. These plants may provide a source of novel anthelmintic drug leads, which are urgently required due to the problem of global anthelmintic resistance. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Accident rates at a busy diving centre.

    PubMed

    Davis, Michael; Malcolm, Kate

    2008-06-01

    Dear Editor, The Poor Knights Islands in Northland, New Zealand, is a world-famous, temperate-water, diving tourism destination, popularised many years ago by Jacques Cousteau. By far the largest dive operator there is Dive! Tutukaka, with five vessels carrying up to 30 divers, operating on a regular basis throughout the year. Dive! Tutukaka is required to keep a detailed, daily vessel manifest. Thus, the number of divers is known accurately and all incidents are recorded by the Skipper or the Chief Divemaster on board. Although all dives are logged (time in, time out and maximum depth for every diver) and kept permanently, these data were not utilised for this brief report. Each customer does two dives on a trip and there are between one and four divemasters on board who may do one, two or more dives a day (van der Hulst G, unpublished observations). Thus the accident rate per diver is known, and it is assumed that the rate per dive is very close to half this figure. In addition, under health and safety regulations all non-diving injuries both on shore and on board are documented, but these will include some non-divers. For the three financial years between July 2005 and 14 June 2008, 32,302 customers dived with Dive! Tutukaka, approximately 63,000 dives (a small minority did only one dive). Over the same period, there were an estimated 7,600 dives conducted by the divemasters. The injuries documented during this time are shown in Table 1. There were seven cases of decompression illness (DCI), a rate of about 1 per 10,000 divers (0.5 per 10,000 dives). Two of the seven DCI cases involved serious neurological injury. There was one further possible case of DCI who did not seek medical advice. If this diver is included then the rate is 1.14 per 10,000 divers. More minor diving injuries and incidents occurred at a rate of approximately 2 per 10,000 divers. Non-diving injuries occurred rarely, the most common being various musculo-skeletal injuries to staff, requiring time off work. Many of these were secondary to lifting and carrying heavy diving equipment, particularly dive tanks. This indicates an area where improved practices by staff could be achieved. We believe these injury data are robust and provide an accurate picture of a single, mainstream, international tourism diving centre in temperate waters, and indicate a low rate of injury, comparable to the international literature.

  14. HIV risk-taking behaviour among injecting drug users currently, previously and never enrolled in methadone treatment.

    PubMed

    Baker, A; Kochan, N; Dixon, J; Wodak, A; Heather, N

    1995-04-01

    This study compares the injecting and sexual risk-taking behaviour among injecting drug users (IDUs) currently, previously and never enrolled in methadone maintenance treatment (MMT). All subjects had injected during the 6 months prior to the day of interview. The current MMT group showed significantly lower injecting risk-taking behaviour subscale scores on the HIV Risk-taking Behaviour Scale (HRBS) of the Opiate Treatment Index than the previous MMT and non-MMT groups together. The current MMT group differed from the other two groups in the frequency of injecting and cleaning of injection equipment with bleach. There was no difference between the current MMT group and the other two groups combined in sexual risk-taking behaviour scores on the HRBS. There were no differences between the previous MMT and non-MMT groups in injecting and sexual risk-taking behaviour. HIV seroprevalence was low and there was no difference in seroprevalence between groups. Thus, IDUs currently enrolled in MMT are at reduced risk for HIV infection when compared with IDUs who have previously or never been enrolled in MMT. However, the absence of a difference between the current MMT and other two groups in frequency of sharing behaviours suggests the need for additional strategies among MMT clients to reduce needle-sharing. Possible strategies include the application of relapse prevention interventions and the availability of sterile injecting equipment in MMT clinics. Further research is needed to identify factors which increase attraction and retention of IDUs to MMT.

  15. Heliotropamide, a novel oxopyrrolidine-3-carboxamide from Heliotropium ovalifolium.

    PubMed

    Guntern, A; Ioset, J-R; Queiroz, E F; Sándor, P; Foggin, C M; Hostettmann, K

    2003-12-01

    Heliotropamide (1), a new alkaloid with a novel oxopyrrolidine-3-carboxamide central moiety, has been isolated as the major product of the dicholoromethane extract of Heliotropium ovalifolium aerial parts. Its structure was elucidated by spectrometric methods including ESI-HR, EI, D/CI mass spectrometry, (1)H, (13)C, and 2D NMR experiments, and chemical derivatization. Neither heliotropamide nor its acetylated derivative (1a) showed any antifungal activity against Cladosporium cucumerinum and Candida albicans, antibacterial activity against Bacillus subtilis, radical-scavenging properties in the DPPH test, or inhibitory potential toward acetylcholinesterase.

  16. Measurement Systems Advisory Group

    DTIC Science & Technology

    1974-04-01

    US NavyLib MSAG- 1 REPORT 001 qL5 ID I APRIL 1974 MA2C91SMAR 2 0 19 81 F Prepared For "LONG RANGE ACOUSTIC PROPAGATION PROJECT 7 opt/ icl S[ D _STRIBU...34 j •( - _> ...ailability Codes IV !VM Avail and/or -~’Dist IspecialL K OFFICE OF NAVAL RESEARCH Department of the Navy Washington, D.C.I L 1 April 23...respect and very much appreciated. The report will be distributed to selected members of the user community for their information and comment. Because 1

  17. Evaluation of Causes of Large 96-H and 120-H Track Errors in the Western North Pacific

    DTIC Science & Technology

    2006-06-01

    Interpolated GFS (A) forecast track for 11W ( Mawar ) for the 0600 UTC 22 August 2005 E-DCI-m case study. The solid sections of the forecast tracks...fields for 11W ( Mawar ) predicted by GFS for taus (a) 54 and (c) 66 for 0600 UTC 22 August 2005 and the corresponding verifying 00-h NOGAPS analyses...pressure (mb) fields for 11W ( Mawar ) predicted by GFS for taus (a) 90 and (c) 114 for 0600 UTC 22 August 2005 and the corresponding verifying 00-h

  18. Environmental Degradation of Fuels, Fluids and Related Materials for Aircraft

    DTIC Science & Technology

    1976-03-01

    23. As a final step of this treatment, the tube is rinsed with hot (200*F) 5% oxalic acid solution to remove metal oxides and com- plex salts. This...of DuPont Method for Deter- 70 mination of DCI-4A Corrosion Inhibitor D. Determination of Total Acid Number for 71 Coirosion Inhibitor No. 4269-28 E...Analyses of Hydrocarbon Fuels 58 18 Heat of Combustion of Benzoic Acid 60 19 Heat of Combustion Values for Ten JP-4 Specimens 61 ix -I /𔃻 " ’ List of Tables

  19. Numerical Studies of Localized Vibrating Structures in Nonlinear Lattices

    DTIC Science & Technology

    1991-03-01

    transmit soliton pulses, greatly increasing the permissible time-bandwidth product of a given system ( Hasegawa and Tappert [1973]). Solitons, which are...CIO CD 0 Fi->ue111.4 F ia aknlk tt fe rg ndcy 8 !78 CoI I o (0))ep Udw FiUeI1.4 FiaIak lk tt afe riho dcy I 78 IV. THE NONLINEAR LATTICE II...equation", PysiCa. D41, 341-355. Hasegawa , A. and Tappert, F. : ’Transmission of stationary nonlinear optical pulses in dispersive dielectric fibers

  20. Late Rather Than Early Onset Bubbles in the Pulmonary Artery During Altitude Exposures Correlate Better with the Onset of "Pain-Only" Decompression Illness

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Gernhardt, M. L.; Powell, M. R.

    2005-01-01

    Mechanistic insight about "pain-only" decompression illness (DCI) is limited given indirect information about venous gas emboli (VGE) detected in the pulmonary artery with Doppler ultrasound. However, we show that VGE first detected late in an altitude exposure are closely associated with subsequent symptom onset. Knowing that VGE occur late is an indication that a symptom will occur soon, but this is not a sufficient condition to guarantee that a symptom will occur.

  1. Expanding Primary Care at William Beaumont Army Medical Center to Support an Increased Beneficiary Population Resulting from the 2005 Base Realignment and Closure Commission Report

    DTIC Science & Technology

    2006-07-01

    the Army Health Facility Planning Agency (HFPA). F HFPA Bl s B CCSIMakhldr PA& E ecision MECOM anpowe Support GPRMS SuthWest egion - IM CTRI WEIST (DcI 4...providers or resources. Finally, is there potential for consolidation of staff support areas such as lounges , locker rooms or conference areas (DoD Medical...Organization and Equipment for the ist AD (see appendix I). Utilizing this identified structure, the Army Force Management Support Agency web portal

  2. Meta-expert system for cargo container screening

    NASA Astrophysics Data System (ADS)

    Alberts, David S.

    1994-02-01

    This paper reports upon improvements and extensions of rule-based expert systems and related technologies in the context of their application to the cargo container screening problem. These innovations have been incorporated into a system built for and deployed by U.S. Customs with funding provided by the DCI's Counter Narcotics Committee. Given the serious nature of the drug smuggling threat and the low probability of intercept, the ability to target the extremely limited inspectional resources available to U.S. Customs is a prerequisite for success in fighting the `Drug War.'

  3. Current-limited electron beam injection

    NASA Technical Reports Server (NTRS)

    Stenzel, R. L.

    1977-01-01

    The injection of an electron beam into a weakly collisional, magnetized background plasma was investigated experimentally. The injected beam was energetic and cold, the background plasma was initially isothermal. Beam and plasma dimensions were so large that the system was considered unbounded. The temporal and spatial evolution of the beam-plasma system was dominated by collective effects. High-frequency electrostatic instabilities rapidly thermalized the beam and heated the background electrons. The injected beam current was balanced by a return current consisting of background electrons drifting toward the beam source. The drift between electrons and ions gave rise to an ion acoustic instability which developed into strong three-dimensional turbulence. It was shown that the injected beam current was limited by the return current which is approximately given by the electron saturation current. Non-Maxwellian electron distribution functions were observed.

  4. Understanding and meeting injection device needs in multiple sclerosis: a survey of patient attitudes and practices

    PubMed Central

    Verdun di Cantogno, Elisabetta; Russell, Susan; Snow, Tom

    2011-01-01

    Background: All established disease-modifying drugs for multiple sclerosis require parenteral administration, which can cause difficulties for some patients, sometimes leading to suboptimal adherence. A new electronic autoinjection device has been designed to address these issues. Methods: Patients with relapsing multiple sclerosis currently receiving subcutaneous or intramuscular interferon beta-1a, interferon beta-1b, or glatiramer acetate completed an online questionnaire (July 4–25, 2008) that surveyed current injection practices, experiences with current injection methods, and impressions and appeal of the new device. Results: In total, 422 patients completed the survey, of whom 44% used autoinjectors, 43% prefilled syringes, and 13% syringes and vials; overall, 66% currently self-injected. Physical and psychological barriers to self-injection included difficulty with injections, needle phobia, and concerns over correct injection technique. Only 40% of respondents were “very satisfied” with their current injection method. The new electronic autoinjector was rated as “very appealing” by 65% of patients. The benefits of the new device included the ability to customize injection settings and to review dosing history. Conclusion: New technologies may help patients overcome physical and psychological barriers to self-injection. The combination of a reliable and flexible autoinjection device with dose-monitoring technology may improve communication between health care professionals and patients, and improve treatment adherence. PMID:21573048

  5. Association between prescription drug misuse and injection among runaway and homeless youth

    PubMed Central

    Al-Tayyib, Alia A; Rice, Eric; Rhoades, Harmony; Riggs, Paula

    2013-01-01

    Background The nonmedical use of prescription drugs is the fastest growing drug problem in the United States, disproportionately impacting youth. Furthermore, the population prevalence of injection drug use among youth is also on the rise. This short communication examines the association between current prescription drug misuse (PDM) and injection among runaway and homeless youth. Methods Homeless youth were surveyed between October, 2011 and February, 2012 at two drop-in service agencies in Los Angeles, CA. Prevalence ratios (PR) and 95% confidence intervals (CI) for the association between current PDM and injection behavior were estimated. The outcome of interest was use of a needle to inject any illegal drug into the body during the past 30 days. Results Of 380 homeless youth (median age, 21; IQR, 17-25; 72% male), 84 (22%) reported current PDM and 48 (13%) reported currently injecting. PDM during the past 30 days was associated with a 7.7 (95% CI: 4.4, 13.5) fold increase in the risk of injecting during that same time. Among those reporting current PDM with concurrent heroin, cocaine, and methamphetamine use, the PR with injection was 15.1 (95% CI: 8.5, 26.8). Conclusions Runaway and homeless youth are at increased risk for a myriad of negative outcomes. Our preliminary findings are among the first to show the strong association between current PDM and injection in this population. Our findings provide the basis for additional research to delineate specific patterns of PDM and factors that enable or inhibit transition to injection among homeless and runaway youth. PMID:24300900

  6. Association between prescription drug misuse and injection among runaway and homeless youth.

    PubMed

    Al-Tayyib, Alia A; Rice, Eric; Rhoades, Harmony; Riggs, Paula

    2014-01-01

    The nonmedical use of prescription drugs is the fastest growing drug problem in the United States, disproportionately impacting youth. Furthermore, the population prevalence of injection drug use among youth is also on the rise. This short communication examines the association between current prescription drug misuse (PDM) and injection among runaway and homeless youth. Homeless youth were surveyed between October 2011 and February 2012 at two drop-in service agencies in Los Angeles, CA. Prevalence ratios (PR) and 95% confidence intervals (CI) for the association between current PDM and injection behavior were estimated. The outcome of interest was use of a needle to inject any illegal drug into the body during the past 30 days. Of 380 homeless youth (median age, 21; IQR, 17-25; 72% male), 84 (22%) reported current PDM and 48 (13%) reported currently injecting. PDM during the past 30 days was associated with a 7.7 (95% CI: 4.4, 13.5) fold increase in the risk of injecting during that same time. Among those reporting current PDM with concurrent heroin, cocaine, and methamphetamine use, the PR with injection was 15.1 (95% CI: 8.5, 26.8). Runaway and homeless youth are at increased risk for a myriad of negative outcomes. Our preliminary findings are among the first to show the strong association between current PDM and injection in this population. Our findings provide the basis for additional research to delineate specific patterns of PDM and factors that enable or inhibit transition to injection among homeless and runaway youth. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Effect of high current density to defect generation of blue LED and its characterization with transmission electron microscope

    NASA Astrophysics Data System (ADS)

    Gunawan, R.; Sugiarti, E.; Isnaeni; Purawiardi, R. I.; Widodo, H.; Muslimin, A. N.; Yuliasari; Ronaldus, C. E.; Prastomo, N.; Hastuty, S.

    2018-03-01

    The optical, electrical and structural characteristics of InGaN-based blue light-emitting diodes (LEDs) were investigated to identify the degradation of LED before and after current injection. The sample was injected by high current of 200 A/cm2 for 5 and 20 minutes. It was observed that injection of current shifts light intensity and wavelength characteristics that indicated defect generation. Transmission Electron Microscopy (TEM) characterization was carried out in order to clarify the structure degradation caused by defect in active layer which consisted of 14 quantum well with thickness of about 5 nm and confined with barrier layer with thickness of about 12 nm. TEM results showed pre-existing defect in LED before injection with high current. Furthermore, discontinue and edge defect was found in dark spot region of LED after injection with high current.

  8. Residual lower esophageal sphincter pressure as a prognostic factor in the pneumatic balloon treatment of achalasia.

    PubMed

    Park, Jung Ho; Lee, Yong Chan; Lee, Hyuk; Park, Hyojin; Youn, Young Hoon; Park, Hyung Seok; Lee, Tae Hee; Hong, Kyoung Sup

    2015-01-01

    Pneumatic balloon dilatation (PD) is a mainstay in achalasia treatment. The aim of this study was to identify predictive factors for successful treatment. We retrospectively reviewed 76 patients with a diagnosis of achalasia who underwent PD from June 2010 to May 2013. Clinical symptoms were assessed using Eckardt score and manometry data were analyzed using resting and relaxation pressure (4sIRP) of lower esophageal sphincter (LES) and the distal contractile integral (DCI), which was calculated for 10 s from the start of deglutition between the upper margin of the LES and lower margin of upper esophageal contraction. Patients with achalasia were classified into three groups based on the Chicago classification. Among 76 patients, 52 patients received PD, and the treatment was unsuccessful in 9 patients (6 in class I and 3 in class III). When comparing prognostic factors between successful and unsuccessful treatment groups, the mean value for 4sIRP in the unsuccessful treatment group was significantly lower than that in the successful treatment group (P < 0.05). However, no difference was noticed in resting LES pressure, DCI, age, and sex. Furthermore, a lower mean value of 4sIRP was significantly related to unsuccessful treatment of achalasia (odds ratio, 1.092; 95% confidence interval, 1.001-1.191) even after adjustment for a series of confounding factors. Lower 4sIRP may be a prognostic indicator for poor treatment outcome after PD. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  9. Esophageal motility after peroral endoscopic myotomy for achalasia.

    PubMed

    Hu, Yue; Li, Meng; Lu, Bin; Meng, Lina; Fan, Yihong; Bao, Haibiao

    2016-05-01

    Peroral endoscopic myotomy (POEM) has been introduced as a novel endoscopic treatment for achalasia. The aim of this work is to assess the changes in esophageal motility caused by POEM in patients with achalasia. Forty-one patients with achalasia underwent POEM from September 2012 to November 2014. Esophageal motility of all patients was evaluated preoperatively and 1 month after POEM utilizing high-resolution manometry, which was performed with ten water swallows, ten steamed bread swallows, and multiple rapid swallows (MRS). In single swallows, including liquid swallows and bread swallows, all the parameters of lower esophagus sphincter resting pressure (LESP), 4-s integrated relaxation pressure (4sIRP), and intra-bolus pressure (IBP) were decreased between pre- and post-POEM patients (all p < 0.05). Postoperatively, the trend of distal contractile integral (DCI) and distal esophageal peristaltic amplitude declined in subtype II and subtype III (subtype II: p < 0.05; subtype III: p > 0.05), but increased in subtype I (subtype I: p > 0.05). In liquid swallows, the Eckardt score of subtype II patients decreased with DCI, and distal esophageal peristaltic amplitude after POEM was significantly lower compared with those showing increased values of those two parameters (p < 0.05). In MRS, the rate of LES relaxation increased from 66.67 to 95.24%, but without normal response in all achalasia patients. POEM reduces LES pressure in achalasia, and partly restores esophageal motility. POEM displayed varying effect on esophageal motility in patients with different patterns of swallowing. In addition, the changes in parameters associated with esophageal peristalsis correlated with decreases in Eckardt score.

  10. Effect of Hydroxyethyl Starch Solution on Incidence of Acute Kidney Injury in Patients Suffering from Cerebral Vasospasm Following Aneurysmal Subarachnoid Hemorrhage.

    PubMed

    Kieninger, Martin; Unbekannt, Daniel; Schneiker, André; Sinner, Barbara; Bele, Sylvia; Prasser, Christopher

    2017-02-01

    The application of third-generation hydroxyethyl starch (HES) solutions in critically ill patients suffering from aneurysmal subarachnoid hemorrhage (aSAH) was often part of the treatment of delayed cerebral ischemia (DCI). However, there is increasing evidence showing a correlation between the application of HES and the incidence of acute kidney injury (AKI). In a single-center retrospective analysis including 81 patients without a preexisting renal disorder suffering from aSAH who had received higher volumes of 6 % HES 130/0.4 due to standard treatment of DCI, the incidence of AKI during intensive care unit (ICU) stay was recorded using AKIN criteria. Furthermore, the course of serum creatinine after discharge from ICU was observed. 6 % HES 130/0.4 was given over a period of 12.9 ± 7.1 days resulting in a cumulative dose of 12543.2 ± 7743.6 mL. Four patients (4.9 %) fulfilled AKIN criteria stage 1 during ICU stay. In two of these patients, serum creatinine was within normal range again on day of discharge. Five patients showed elevated levels of serum creatinine within 1 to 22 months after hospitalization. A correlation between the amount of HES given and the incidence of AKI could not be found. The application of 6 % HES 130/0.4 did not lead to an elevated incidence of AKI in patients without an elevated baseline serum creatinine. However, there is still a lack of high-level evidence as prospective randomized trials are missing yet.

  11. [Analysis of the characteristic of pharyngeal paraesthesia patients by high resolution manometry].

    PubMed

    Gu, Yun; Qian, Wei

    2015-09-01

    To discuss the pressure changing characteristics of upper esophageal sphincter (UES), lower esophageal sphincter (LES) and the esophagus kinetic characteristics of pharyngeal paraesthesia patients. To take high resolution manometry in 44 cases of pharyngeal paraesthesia patients and 23 normal subjects separately. According to the RSI score,the 44 patients were divided into group A (the group without reflux, RSI < 13, n = 25) and group B (the group with reflux, RSI ≥ 13, n = 19). The UES average resting pressure and average residual pressure of patients group were higher than the control group (P < 0.05); The UES average resting pressure and average residual pressure of group B were higher than group A (P < 0.05); The LES average resting pressure and average residual pressure of group B were lower than group A and the control group (P < 0.05); The comparison of LES average resting pressure and average residual pressure between group A and the control group was not statistically significant (P > 0.05). The esophagus DCI of group B was lower than that of group A and control group (P < 0.05). The esophagus DCI comparison between group A and control group was not statistically significant (P > 0.05). The pharyngeal paresthesia symptoms of'patients was associated with the increasing of UES pressure. The pharyngeal paresthesia symptoms of group with reflux was related to low pressure of LES and high pressure of UES. The last part of esophagus of group with reflux had obstacles in powers, which weaken the peristalsis and declined the ability to clear the bolus and gastric reflux material.

  12. Embedded Protostellar Disks Around (Sub-)Solar Stars. II. Disk Masses, Sizes, Densities, Temperatures, and the Planet Formation Perspective

    NASA Astrophysics Data System (ADS)

    Vorobyov, Eduard I.

    2011-03-01

    We present basic properties of protostellar disks in the embedded phase of star formation (EPSF), which is difficult to probe observationally using available observational facilities. We use numerical hydrodynamics simulations of cloud core collapse and focus on disks formed around stars in the 0.03-1.0 M sun mass range. Our obtained disk masses scale near-linearly with the stellar mass. The mean and median disk masses in the Class 0 and I phases (M mean d,C0 = 0.12 M sun, M mdn d,C0 = 0.09 M sun and M mean d,CI = 0.18 M sun, M mdn d,CI = 0.15 M sun, respectively) are greater than those inferred from observations by (at least) a factor of 2-3. We demonstrate that this disagreement may (in part) be caused by the optically thick inner regions of protostellar disks, which do not contribute to millimeter dust flux. We find that disk masses and surface densities start to systematically exceed that of the minimum mass solar nebular for objects with stellar mass as low as M * = 0.05-0.1 M sun. Concurrently, disk radii start to grow beyond 100 AU, making gravitational fragmentation in the disk outer regions possible. Large disk masses, surface densities, and sizes suggest that giant planets may start forming as early as in the EPSF, either by means of core accretion (inner disk regions) or direct gravitational instability (outer disk regions), thus breaking a longstanding stereotype that the planet formation process begins in the Class II phase.

  13. Effect of current injection into thin-film Josephson junctions

    DOE PAGES

    Kogan, V. G.; Mints, R. G.

    2014-11-11

    New thin-film Josephson junctions have recently been tested in which the current injected into one of the junction banks governs Josephson phenomena. One thus can continuously manage the phase distribution at the junction by changing the injected current. Our method of calculating the distribution of injected currents is also proposed for a half-infinite thin-film strip with source-sink points at arbitrary positions at the film edges. The strip width W is assumed small relative to Λ=2λ 2/d;λ is the bulk London penetration depth of the film material and d is the film thickness.

  14. Formation and dissipation of runaway current by MGI on J-TEXT

    NASA Astrophysics Data System (ADS)

    Wei, Yunong; Chen, Zhongyong; Huang, Duwei; Tong, Ruihai; Zhang, Xiaolong

    2017-10-01

    Plasma disruptions are one of the major concern for ITER. A large fraction of runaway current may be formed due to the avalanche generation of runaway electrons (REs) during disruptions and ruin the device structure. Experiments of runaway current formation and dissipation have been done on J-TEXT. Two massive gas injection (MGI) valves are used to form and dissipate the runaway current. Hot tail RE generation caused by the fast thermal quench leads to an abnormal formation of runaway current when the pre-TQ electron density increases in a range of 0.5-2-10 19m-3. 1020-22 quantities of He, Ne, Ar or Kr impurities are injected by MGI2 to dissipate the runaway current. He injection shows no obvious effect on runaway current dissipation in the experiments and Kr injection shows the best. The kinetic energy of REs and the magnetic energy of RE beam will affect the dissipation efficiency to a certain extent. Runaway current decay rate is found increasing quickly with the increase of the gas injection when the quantity is moderate, and then reaches to a saturation value with large quantity injection. A possible reason to explain the saturation of dissipation effect is the saturation of gas assimilation efficiency.

  15. Contraction produced by intracellular injection of calcium, strontium, and barium in the single crayfish muscle fibers.

    PubMed

    Matsumura, M; Mashima, H

    1976-01-01

    Ca ions were ionophoretically injected through an intracellular microelectrode into the single muscle fiber of a crayfish, and the resulting contraction sphere was observed under a microscope and photographed with a movie camera. The minimum contraction produced by the threshold current involved usually three or four, sometimes two, sarcomers on both sides of the injecting pipette but contraction involving only one sarcomere was not observered. The rheobase of the Ca-injecting current was 3.2 X 10(-9) A. The strength-duration curves were determined for Ca-, Sr-, and Ba-injecting currents; all fitted a similar hyperbolic equation. The threshold amount of Ca above rheobasic injection was 2.1 X 10(-15)mol, and the ratios between threshold amounts were Ca: Sr: Ba=1: 1.9: 3.0. The effects of Ca and Sr were additive for the contraction. More current was required for the Ca-injection to produce the contraction in the K-depolarized-or 15mM-procaine-treated muscle, although less current was sufficient for the muscle treated with 0.5-1.0 mM of caffeine. The participation of the Ca-induced Ca release mechanism in the contraction produced by Ca injection and the role of Sr or Ba as a substitute for Ca were discussed.

  16. A kinetic Monte Carlo model with improved charge injection model for the photocurrent characteristics of organic solar cells

    NASA Astrophysics Data System (ADS)

    Kipp, Dylan; Ganesan, Venkat

    2013-06-01

    We develop a kinetic Monte Carlo model for photocurrent generation in organic solar cells that demonstrates improved agreement with experimental illuminated and dark current-voltage curves. In our model, we introduce a charge injection rate prefactor to correct for the electrode grid-size and electrode charge density biases apparent in the coarse-grained approximation of the electrode as a grid of single occupancy, charge-injecting reservoirs. We use the charge injection rate prefactor to control the portion of dark current attributed to each of four kinds of charge injection. By shifting the dark current between electrode-polymer pairs, we align the injection timescales and expand the applicability of the method to accommodate ohmic energy barriers. We consider the device characteristics of the ITO/PEDOT/PSS:PPDI:PBTT:Al system and demonstrate the manner in which our model captures the device charge densities unique to systems with small injection energy barriers. To elucidate the defining characteristics of our model, we first demonstrate the manner in which charge accumulation and band bending affect the shape and placement of the various current-voltage regimes. We then discuss the influence of various model parameters upon the current-voltage characteristics.

  17. Computational modeling of the effect of external electron injection into a direct-current microdischarge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panneer Chelvam, Prem Kumar; Raja, Laxminarayan L.

    2015-12-28

    Electron emission from the electrode surface plays an important role in determining the structure of a direct-current microdischarge. Here we have developed a computational model of a direct-current microdischarge to study the effect of external electron injection from the cathode surface into the discharge to manipulate its properties. The model provides a self-consistent, multi-species, multi-temperature fluid representation of the plasma. A microdischarge with a metal-insulator-metal configuration is chosen for this study. The effect of external electron injection on the structure and properties of the microdischarge is described. The transient behavior of the microdischarge during the electron injection is examined. Themore » nonlinearities in the dynamics of the plasma result in a large increase of conduction current after active electron injection. For the conditions simulated a switching time of ∼100 ns from a low-current to high-current discharge state is realized.« less

  18. Investigation of Bose Condensation in Ideal Bose Gas Trapped under Generic Power Law Potential in d Dimension

    NASA Astrophysics Data System (ADS)

    Mehedi Faruk, Mir; Sazzad Hossain, Md.; Muktadir Rahman, Md.

    2016-02-01

    The changes in characteristics of Bose condensation of ideal Bose gas due to an external generic power law potential U=\\sumi=1dci\\vert xi/ai\\vertni are studied carefully. Detailed calculation of Kim et al. (J. Phys. Condens. Matter 11 (1999) 10269) yielded the hierarchy of condensation transitions with changing fractional dimensionality. In this manuscript, some theorems regarding specific heat at constant volume CV are presented. Careful examination of these theorems reveal the existence of hidden hierarchy of the condensation transition in trapped systems as well.

  19. Optimal design strategy of switching converters employing current injected control

    NASA Astrophysics Data System (ADS)

    Lee, F. C.; Fang, Z. D.; Lee, T. H.

    1985-01-01

    This paper analyzes a buck/boost regulator employing current-injected control (CIC). It reveals the complex interactions between the dc loop and the current-injected loop and underlines the fundamental principle that governs the loop gain determination. Three commonly used compensation techniques are compared. The integral and lead/lag compensation are shown to be most desirable for performance optimization and stability.

  20. Prognostic health monitoring in switch-mode power supplies with voltage regulation

    NASA Technical Reports Server (NTRS)

    Hofmeister, James P (Inventor); Judkins, Justin B (Inventor)

    2009-01-01

    The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

  1. Current drive by spheromak injection into a tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, M.R.; Bellan, P.M.

    1990-04-30

    We report the first observation of current drive by injection of a spheromak plasma into a tokamak (Caltech ENCORE small reasearch tokamak) due to the process of helicity injection. After an abrupt 30% increase, the tokamak current decays by a factor of 3 due to plasma cooling caused by the merging of the relatively cold spheromak with the tokamak. The tokamak density profile peaks sharply due to the injected spheromak plasma ({ital {bar n}}{sub 3} increases by a factor of 6) then becomes hollow, suggestive of an interchange instability.

  2. Robust spin-current injection in lateral spin valves with two-terminal Co2FeSi spin injectors

    NASA Astrophysics Data System (ADS)

    Oki, S.; Kurokawa, T.; Honda, S.; Yamada, S.; Kanashima, T.; Itoh, H.; Hamaya, K.

    2017-05-01

    We demonstrate generation and detection of pure spin currents by combining a two-terminal spin-injection technique and Co2FeSi (CFS) spin injectors in lateral spin valves (LSVs). We find that the two-terminal spin injection with CFS has the robust dependence of the nonlocal spin signals on the applied bias currents, markedly superior to the four-terminal spin injection with permalloy reported previously. In our LSVs, since the spin transfer torque from one CFS injector to another CFS one is large, the nonlocal magnetoresistance with respect to applied magnetic fields shows large asymmetry in high bias-current conditions. For utilizing multi-terminal spin injection with CFS as a method for magnetization reversals, the terminal arrangement of CFS spin injectors should be taken into account.

  3. A current-driven resistive instability and its nonlinear effects in simulations of coaxial helicity injection in a tokamak

    DOE PAGES

    Hooper, E. B.; Sovinec, C. R.

    2016-10-06

    An instability observed in whole-device, resistive magnetohydrodynamic simulations of the driven phase of coaxial helicity injection in the National Spherical Torus eXperiment is identified as a current-driven resistive mode in an unusual geometry that transiently generates a current sheet. The mode consists of plasma flow velocity and magnetic field eddies in a tube aligned with the magnetic field at the surface of the injected magnetic flux. At low plasma temperatures (~10–20 eV), the mode is benign, but at high temperatures (~100 eV) its amplitude undergoes relaxation oscillations, broadening the layer of injected current and flow at the surface of themore » injected toroidal flux and background plasma. The poloidal-field structure is affected and the magnetic surface closure is generally prevented while the mode undergoes relaxation oscillations during injection. Furthermore, this study describes the mode and uses linearized numerical computations and an analytic slab model to identify the unstable mode.« less

  4. Dark Current Characterization of SW HgCdTe IRFPAs Detectors on Si Substrate with Long Time Integration

    NASA Astrophysics Data System (ADS)

    Song, P. Y.; Ye, Z. H.; Huang, A. B.; Chen, H. L.; Hu, X. N.; Ding, R. J.; He, L.

    2016-09-01

    The dark currents of two short wave (SW) HgCdTe infrared focal plane arrays (IRFPA) detectors hybridized with direct injection (DI) readout and capacitance transimpedance amplifier (CTIA) with long time integration were investigated. The cutoff wavelength of the two SW IRFPAs is about 2.6 μm at 84 K. The dark current densities of DI and CTIA samples are approximately 8.0 × 10-12 A/cm2 and 7.2 × 10-10 A/cm2 at 110 K, respectively. The large divergence of the dark current density might arise from the injection efficiency difference of the two readouts. The low injection efficiency of the DI readout, compared with the high injection efficiency of the CTIA readout at low temperature, makes the dark current density of the DI sample much lower than that of the CTIA sample. The experimental value of injection efficiency of the DI sample was evaluated as 1.1% which is consistent with its theoretical value.

  5. Comparison of two high-resolution manometry software systems in evaluating esophageal motor function.

    PubMed

    Rengarajan, A; Drapekin, J; Patel, A; Gyawali, C P

    2016-12-01

    High-resolution manometry (HRM) utilizes software tools to diagnose esophageal motor disorders. Performance of these software metrics could be affected by averaging and by software characteristics of different manufacturers. High-resolution manometry studies on 86 patients referred for antireflux surgery (61.6 ± 1.4 year, 70% F) and 20 healthy controls (27.9 ± 0.7 year, 45% F) were first subject to standard analysis (Medtronic, Duluth, GA, USA). Coordinates for each of 10 test swallows were exported and averaged to generate a composite swallow. The swallows and averaged composites were imported as ASCII file format into Manoview (Medtronic) and Medical Measurement Systems database reporter (MMS, Dover, NH, USA), and analyses repeated. Comparisons were made between standard and composite swallow interpretations. Correlation between the two systems was high for mean distal contractile integral (DCI, r 2 ≥ 0.9) but lower for integrated relaxation pressure (IRP, r 2 = 0.7). Excluding achalasia, six patients with outflow obstruction (mean IRP 23.2 ± 2.1 with 10-swallow average) were identified by both systems. An additional nine patients (10.5%) were identified as outflow obstruction (15 mmHg threshold) with MMS 10-swallow and four with MMS composite swallow evaluation; only one was confirmed. Ineffective esophageal motility was diagnosed by 10-swallow evaluation in 19 (22.1%) with Manoview, and 20 (23.3%) with MMS. On Manoview composite, 17 had DCI <450 mmHg/cm/s, and on MMS composite, 21, (p ≥ 0.85 for each comparison) but these did not impact diagnostic conclusions. Comparison of 10 swallow and composite swallows demonstrate variability in software metrics between manometry systems. Our data support use of manufacturer specific software metrics on 10-swallow sequences. © 2016 John Wiley & Sons Ltd.

  6. [Dyadic coping and well-being -- the Hungarian version of the Dyadic Coping Inventory].

    PubMed

    Martos, Tamás; Sallay, Viola; Nistor, Michaela; Józsa, Péter

    2012-01-01

    In studying coping processes, there is often a focus on individual coping while dyadic processes in couples are seldom addressed. Therefore we present here data with the Hungarian version of the Dyadic Coping Inventory (DCI) that was developed to assess dyadic forms of coping (e.g., stress communication, support, delegated and negative coping). 473 adult participants, living in committed relationships (176 male and 296 female, aged 34,0 +/- 11,9 years) were involved in a questionnaire study. Along with the Hungarian version of the Dyadic Coping Inventory we assessed satisfaction with life (SWLS) and marital satisfaction (Marital Stress Scale). Subscales of the Dyadic Coping Inventory were found reliable and the expected factor structure for both the dyadic coping of oneself and the partner were replicable. Moreover, specific forms of dyadic coping accounted for significant amount of explained variance in life satisfaction (31,8 and 27,7% for male and female respondents) and marital satisfaction (1,8 and 48,5%). Results imply possible gender differences, since marital satisfaction of women was negatively predicted both by negative coping of oneself and the partner (betas=-0,174 and -0,152), and positively by the support of the partner and the evaluation of the common dyadic coping (betas= 0,255 and 0,187), whereas there was only one significant link in male respondents, supportive coping of oneself (beta= 0,320). Results show that 1. the Hungarian version of the DCI is a reliable and valid measure, and 2. there may be specific gender differences in dyadic coping that has to be considered when planning further research, training programs and therapeutic interventions for couples.

  7. The Dominance Concept Inventory: A Tool for Assessing Undergraduate Student Alternative Conceptions about Dominance in Mendelian and Population Genetics.

    PubMed

    Abraham, Joel K; Perez, Kathryn E; Price, Rebecca M

    2014-01-01

    Despite the impact of genetics on daily life, biology undergraduates understand some key genetics concepts poorly. One concept requiring attention is dominance, which many students understand as a fixed property of an allele or trait and regularly conflate with frequency in a population or selective advantage. We present the Dominance Concept Inventory (DCI), an instrument to gather data on selected alternative conceptions about dominance. During development of the 16-item test, we used expert surveys (n = 12), student interviews (n = 42), and field tests (n = 1763) from introductory and advanced biology undergraduates at public and private, majority- and minority-serving, 2- and 4-yr institutions in the United States. In the final field test across all subject populations (n = 709), item difficulty ranged from 0.08 to 0.84 (0.51 ± 0.049 SEM), while item discrimination ranged from 0.11 to 0.82 (0.50 ± 0.048 SEM). Internal reliability (Cronbach's alpha) was 0.77, while test-retest reliability values were 0.74 (product moment correlation) and 0.77 (intraclass correlation). The prevalence of alternative conceptions in the field tests shows that introductory and advanced students retain confusion about dominance after instruction. All measures support the DCI as a useful instrument for measuring undergraduate biology student understanding and alternative conceptions about dominance. © 2014 J. K. Abraham et al. CBE—Life Sciences Education © 2014 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  8. Effects of viscosity and volume on the patterns of esophageal motility in healthy adults using high-resolution manometry.

    PubMed

    Park, J H; Lee, H; Rhee, P-L; Park, J H

    2015-01-01

    The purpose of this study was to determine the effects of age, sex, body mass index (BMI), viscosity, and volume on esophageal motility using high-resolution manometry (HRM). Manometric studies were performed on 60 asymptomatic volunteers (27 men and 33 women, age: 19-56 years) while in a supine position. Manometric protocol included 10 water swallows (5 cc), 10 jelly swallows (5 cc), and 1 water swallow (20 cc). Evaluation of HRM parameters including length of proximal pressure trough (PPT length), distal latency (DL), contractile front velocity (CFV), distal contractile integral (DCI), and 4-second integrated relaxation pressure (IRP) was performed using MATLAB. Significant differences were noted in median IRP between water 5 cc (median 7.2 mmHg [range 5.5-9.6]), jelly 5 cc (median 6.0 mmHg [range 3.8-8.0]), and water 20 cc {(Median 4.8 mmHg [range 3.3-7.4]), P < 0.01}. DL were significantly different between water 5 cc, jelly 5 cc, and water 20 cc (P < 0.01), and in terms of PPT, proportions of small (2 cm ≤ < 5 cm) and large (5 cm≤) break for jelly 5 cc were significantly higher than those for the water 5 cc swallow (P < 0.05). Furthermore, DCI increased with age for water 5 cc, and a significant negative correlation was noticed between proportions of small break and BMI for water 5 cc. Manometric measurements vary depending on age, BMI, viscosity, and volume. These findings need to be taken into account in the interpretation of manometry results. © 2014 International Society for Diseases of the Esophagus.

  9. Rv0004 is a new essential member of the mycobacterial DNA replication machinery

    PubMed Central

    Hooppaw, Anna J.; Richardson, Kirill; Lee, Hark Joon; Kimmey, Jacqueline M.; Aldridge, Bree B.

    2017-01-01

    DNA replication is fundamental for life, yet a detailed understanding of bacterial DNA replication is limited outside the organisms Escherichia coli and Bacillus subtilis. Many bacteria, including mycobacteria, encode no identified homologs of helicase loaders or regulators of the initiator protein DnaA, despite these factors being essential for DNA replication in E. coli and B. subtilis. In this study we discover that a previously uncharacterized protein, Rv0004, from the human pathogen Mycobacterium tuberculosis is essential for bacterial viability and that depletion of Rv0004 leads to a block in cell cycle progression. Using a combination of genetic and biochemical approaches, we found that Rv0004 has a role in DNA replication, interacts with DNA and the replicative helicase DnaB, and affects DnaB-DnaA complex formation. We also identify a conserved domain in Rv0004 that is predicted to structurally resemble the N-terminal protein-protein interaction domain of DnaA. Mutation of a single conserved tryptophan within Rv0004’s DnaA N-terminal-like domain leads to phenotypes similar to those observed upon Rv0004 depletion and can affect the association of Rv0004 with DnaB. In addition, using live cell imaging during depletion of Rv0004, we have uncovered a previously unappreciated role for DNA replication in coordinating mycobacterial cell division and cell size. Together, our data support that Rv0004 encodes a homolog of the recently identified DciA family of proteins found in most bacteria that lack the DnaC-DnaI helicase loaders in E. coli and B. subtilis. Therefore, the mechanisms of Rv0004 elucidated here likely apply to other DciA homologs and reveal insight into the diversity of bacterial strategies in even the most conserved biological processes. PMID:29176877

  10. Host-guest complex of N-(2-chloroethyl), N-nitroso, N‧, N‧ -dicyclohexylsulfamid with β-cyclodextrin: Fluorescence, QTAIM analysis and structure-chemical reactivity

    NASA Astrophysics Data System (ADS)

    Bensouilah, Nadjia; Fisli, Hassina; Bensouilah, Hamza; Zaater, Sihem; Abdaoui, Mohamed; Boutemeur-Kheddis, Baya

    2017-10-01

    In this work, the inclusion complex of DCY/CENS: N-(2-chloroethyl), N-nitroso, N‧, N‧-dicyclohexylsulfamid and β-cyclodextrin (β-CD) is investigated using the fluorescence spectroscopy, PM3, ONIOM2 and DFT methods. The experimental part reveals that DCY/CENS forms a 1:1 stoichiometric ratio inclusion complex with β-CD. The constant of stability is evaluated using the Benesi-Hildebrand equation. The results of the theoretical optimization showed that the lipophilic fraction of molecule (cyclohexyl group) is inside of β-CD. Accordingly, the Nitroso-Chloroethyl moiety is situated outside the cavity of the macromolecule host. The favorable structure of the optimized complex indicates the existence of weak intermolecular hydrogen bonds and the most important van der Waals (vdW) interactions which are studied on the basis of Natural Bonding Orbital (NBO) analysis. The NBO is employed to compute the electronic donor-acceptor exchanges between drug and β-CD. Furthermore, a detailed topological charge density analysis based on the quantum theory of atoms in molecules (QTAIM), has been accomplished on the most favorable complex using B3LYP/6-31G(d) method. The presence of stabilizing intermolecular hydrogen bonds and van der Waals interactions in the most favorable complex is predicted. Also, the energies of these interactions are estimated with Espinosa's formula. The findings of this investigation reveal that the correlation between the structural parameters and the electronic density is good. Finally, and based on DFT calculations, the reactivity of the interesting molecule in free state was studied and compared with that in the complexed state using chemical potential, global hardness, global softness, electronegativity, electrophilicity and local reactivity descriptors.

  11. Rv0004 is a new essential member of the mycobacterial DNA replication machinery.

    PubMed

    Mann, Katherine M; Huang, Deborah L; Hooppaw, Anna J; Logsdon, Michelle M; Richardson, Kirill; Lee, Hark Joon; Kimmey, Jacqueline M; Aldridge, Bree B; Stallings, Christina L

    2017-11-01

    DNA replication is fundamental for life, yet a detailed understanding of bacterial DNA replication is limited outside the organisms Escherichia coli and Bacillus subtilis. Many bacteria, including mycobacteria, encode no identified homologs of helicase loaders or regulators of the initiator protein DnaA, despite these factors being essential for DNA replication in E. coli and B. subtilis. In this study we discover that a previously uncharacterized protein, Rv0004, from the human pathogen Mycobacterium tuberculosis is essential for bacterial viability and that depletion of Rv0004 leads to a block in cell cycle progression. Using a combination of genetic and biochemical approaches, we found that Rv0004 has a role in DNA replication, interacts with DNA and the replicative helicase DnaB, and affects DnaB-DnaA complex formation. We also identify a conserved domain in Rv0004 that is predicted to structurally resemble the N-terminal protein-protein interaction domain of DnaA. Mutation of a single conserved tryptophan within Rv0004's DnaA N-terminal-like domain leads to phenotypes similar to those observed upon Rv0004 depletion and can affect the association of Rv0004 with DnaB. In addition, using live cell imaging during depletion of Rv0004, we have uncovered a previously unappreciated role for DNA replication in coordinating mycobacterial cell division and cell size. Together, our data support that Rv0004 encodes a homolog of the recently identified DciA family of proteins found in most bacteria that lack the DnaC-DnaI helicase loaders in E. coli and B. subtilis. Therefore, the mechanisms of Rv0004 elucidated here likely apply to other DciA homologs and reveal insight into the diversity of bacterial strategies in even the most conserved biological processes.

  12. Lactobacillus cerevisiae sp. nov., isolated from a spoiled brewery sample.

    PubMed

    Koob, Jennifer; Jacob, Fritz; Wenning, Mareike; Hutzler, Mathias

    2017-09-01

    A Gram-stain-positive, non-motile, rod-shaped bacterium, designated TUM BP 140423000-2250T (=DSM 100836T=LMG 29073T), was isolated from spoiled beer. This bacterium did not form spores, and was catalase-negative and facultatively anaerobic. Its taxonomic position was determined in a polyphasic study. The 16S rRNA gene sequence similarity data showed that the strain belonged to the Lactobacillus genus with the nearest neighbours being Lactobacillus koreensis DCY50T (sequence similarity 99.5 %), Lactobacillus yonginensis THK-V8T (99.2 %) and Lactobacillus parabrevis LMG 11984T (98.7 %). Sequence comparisons of additional phylogenetic markers, pheS and rpoA, confirmed the 16S rRNA gene sequence tree topology. The maximum rpoA sequence similarity was 92.3 % with L. yonginensis THK-V8T. The DNA G+C content of the isolate was 50.0 mol%. The DNA-DNA relatedness showed that strain TUM BP 140423000-2250T could be clearly distinguished from L. koreensis DCY 50T (30.8±0.4 %) and L. yonginensis THK-V8T (23.6±5.9 %). The major fatty acids were C18 : 1ω9c, summed feature 7 (comprised of C19 : 0 cyclo ω10c/C19 : 1ω6c) and C16 : 0. Based on phenotypic and genotypic studies, the authors propose classifying the new isolate as a representative of a novel species of the genus Lactobacillus, Lactobacillus cerevisiae sp. nov. The type strain is deposited at the Research Centre Weihenstephan for Brewing and Food Quality as TUM BP 140423000-2250T (=DSM 100836T=LMG 29073T).

  13. The physicochemical characteristics and anaerobic degradability of desiccated coconut industry waste water.

    PubMed

    Chanakya, H N; Khuntia, Himanshu Kumar; Mukherjee, Niranjan; Aniruddha, R; Mudakavi, J R; Thimmaraju, Preeti

    2015-12-01

    Desiccated coconut industries (DCI) create various intermediates from fresh coconut kernel for cosmetic, pharmaceutical and food industries. The mechanized and non-mechanized DCI process between 10,000 and 100,000 nuts/day to discharge 6-150 m(3) of malodorous waste water leading to a discharge of 264-6642 kg chemical oxygen demand (COD) daily. In these units, three main types of waste water streams are coconut kernel water, kernel wash water and virgin oil waste water. The effluent streams contain lipids (1-55 g/l), suspended solids (6-80 g/l) and volatile fatty acids (VFA) at concentrations that are inhibitory to anaerobic bacteria. Coconut water contributes to 20-50% of the total volume and 50-60% of the total organic loads and causes higher inhibition of anaerobic bacteria with an initial lag phase of 30 days. The lagooning method of treatment widely adopted failed to appreciably treat the waste water and often led to the accumulation of volatile fatty acids (propionic acid) along with long-chain unsaturated free fatty acids. Biogas generation during biological methane potential (BMP) assay required a 15-day adaptation time, and gas production occurred at low concentrations of coconut water while the other two streams did not appear to be inhibitory. The anaerobic bacteria can mineralize coconut lipids at concentrations of 175 mg/l; however; they are severely inhibited at a lipid level of ≥350 mg/g bacterial inoculum. The modified Gompertz model showed a good fit with the BMP data with a simple sigmoid pattern. However, it failed to fit experimental BMP data either possessing a longer lag phase and/or diauxic biogas production suggesting inhibition of anaerobic bacteria.

  14. Short-Wavelength Light-Emitting Devices With Enhanced Hole Injection Currents

    DTIC Science & Technology

    2005-05-01

    hot-hole injector with appreciably enhancement of the injection current is proposed and developed to be integrated with commonly used vertical...structures of the emitting devices. Second, we develop the alternative design of UV-light sources on the base of lateral p+ - i - n+ superlattice structures...enhancement of the injection current is proposed and developed to be integrated with commonly used vertical structures of the emitting devices. Second

  15. Direct memory access transfer completion notification

    DOEpatents

    Chen, Dong; Giampapa, Mark E.; Heidelberger, Philip; Kumar, Sameer; Parker, Jeffrey J.; Steinmacher-Burow, Burkhard D.; Vranas, Pavlos

    2010-07-27

    Methods, compute nodes, and computer program products are provided for direct memory access (`DMA`) transfer completion notification. Embodiments include determining, by an origin DMA engine on an origin compute node, whether a data descriptor for an application message to be sent to a target compute node is currently in an injection first-in-first-out (`FIFO`) buffer in dependence upon a sequence number previously associated with the data descriptor, the total number of descriptors currently in the injection FIFO buffer, and the current sequence number for the newest data descriptor stored in the injection FIFO buffer; and notifying a processor core on the origin DMA engine that the message has been sent if the data descriptor for the message is not currently in the injection FIFO buffer.

  16. Optical intensity dynamics in a five-emitter semiconductor array laser

    NASA Astrophysics Data System (ADS)

    Williams, Matthew O.; Kutz, J. Nathan

    2009-06-01

    The intensity dynamics of a five-emitter laser array subject to a linearly decreasing injection current are examined numerically. We have matched the results of the numerical model to an experimental AlGaAs quantum-dot array laser and have achieved the same robust oscillatory power output with a nearly π phase shift between emitters that was observed in experiments. Due to the linearly decreasing injection current, the output power of the waveguide decreases as a function of waveguide number. For injection currents ranging from 380 to 500 mA, the oscillatory behavior persists with only a slight change in phase difference. However, the fundamental frequency of oscillation increases with injection current, and higher harmonics as well as some fine structures are produced.

  17. Removing the current-limit of vertical organic field effect transistors

    NASA Astrophysics Data System (ADS)

    Sheleg, Gil; Greenman, Michael; Lussem, Bjorn; Tessler, Nir

    2017-11-01

    The reported Vertical Organic Field Effect Transistors (VOFETs) show either superior current and switching speeds or well-behaved transistor performance, especially saturation in the output characteristics. Through the study of the relationship between the device architecture or dimensions and the device performance, we find that achieving a saturation regime in the output characteristics requires that the device operates in the injection limited regime. In current structures, the existence of the injection limited regime depends on the source's injection barrier as well as on the buried semiconductor layer thickness. To overcome the injection limit imposed by the necessity of injection barrier, we suggest a new architecture to realize VOFETs. This architecture shows better gate control and is independent of the injection barrier at the source, thus allowing for several A cm-2 for a semiconductor having a mobility value of 0.1 cm2 V-1 s-1.

  18. Study of local currents in low dimension materials using complex injecting potentials

    NASA Astrophysics Data System (ADS)

    He, Shenglai; Covington, Cody; Varga, Kálmán

    2018-04-01

    A complex potential is constructed to inject electrons into the conduction band, mimicking electron currents in nanoscale systems. The injected electrons are time propagated until a steady state is reached. The local current density can then be calculated to show the path of the conducting electrons on an atomistic level. The method allows for the calculation of the current density vectors within the medium as a function of energy of the conducting electron. Using this method, we investigate the electron pathway of graphene nanoribbons in various structures, molecular junctions, and black phosphorus nanoribbons. By analyzing the current flow through the structures, we find strong dependence on the structural geometry and the energy of the injected electrons. This method may be of general use in the study of nano-electronic materials and interfaces.

  19. High risk behavior for HIV transmission among former injecting drug users: a survey from Indonesia.

    PubMed

    Iskandar, Shelly; Basar, Diba; Hidayat, Teddy; Siregar, Ike M P; Pinxten, Lucas; van Crevel, Reinout; Van der Ven, Andre J A M; De Jong, Cor A J

    2010-08-10

    Injecting drug use is an increasingly important cause of HIV transmission in most countries worldwide, especially in eastern Europe, South America, and east and southeast Asia. Among people actively injecting drugs, provision of clean needles and opioid substitution reduce HIV-transmission. However, former injecting drug users (fIDUs) are often overlooked as a high risk group for HIV transmission. We compared HIV risk behavior among current and former injecting drug users (IDUs) in Indonesia, which has a rapidly growing HIV-epidemic largely driven by injecting drug use. Current and former IDUs were recruited by respondent driven sampling in an urban setting in Java, and interviewed regarding drug use and HIV risk behavior using the European Addiction Severity Index and the Blood Borne Virus Transmission Questionnaire. Drug use and HIV transmission risk behavior were compared between current IDUs and former IDUs, using the Mann-Whitney and Pearson Chi-square test. Ninety-two out of 210 participants (44%) were self reported former IDUs. Risk behavior related to sex, tattooing or piercing was common among current as well as former IDUs, 13% of former IDUs were still exposed to contaminated injecting equipment. HIV-infection was high among former (66%) and current (60%) IDUs. Former IDUs may contribute significantly to the HIV-epidemic in Indonesia, and HIV-prevention should therefore also target this group, addressing sexual and other risk behavior.

  20. Physics of the current injection process during localized helicity injection

    NASA Astrophysics Data System (ADS)

    Hinson, Edward Thomas

    An impedance model has been developed for the arc-plasma cathode electron current source used in localized helicity injection tokamak startup. According to this model, a potential double layer (DL) is established between the high-density arc plasma (narc ˜ 1021 m-3) in the electron source, and the less-dense external tokamak edge plasma (nedge ˜ 10 18 m-3) into which current is injected. The DL launches an electron beam at the applied voltage with cross-sectional area close to that of the source aperture: Ainj ≈ 2 cm 2. The injected current, Iinj, increases with applied voltage, Vinj, according to the standard DL scaling, Iinj ˜ V(3/2/ inj), until the more restrictive of two limits to beam density nb arises, producing Iinj ˜ V(1/2/inj), a scaling with beam drift velocity. For low external tokamak edge density nedge, space-charge neutralization of the intense electron beam restricts the injected beam density to nb ˜ nedge. At high Jinj and sufficient edge density, the injected current is limited by expansion of the DL sheath, which leads to nb ˜ narc. Measurements of narc, Iinj , nedge, Vinj, support these predicted scalings, and suggest narc as a viable control actuator for the source impedance. Magnetic probe signals ≈ 300 degrees toroidally from the injection location are consistent with expectations for a gyrating, coherent electron beam with a compact areal cross-section. Technological development of the source has allowed an extension of the favorable Iinj ˜ V(1/2/inj) to higher power without electrical breakdown.

  1. Effect of injection current and temperature on signal strength in a laser diode optical feedback interferometer.

    PubMed

    Al Roumy, Jalal; Perchoux, Julien; Lim, Yah Leng; Taimre, Thomas; Rakić, Aleksandar D; Bosch, Thierry

    2015-01-10

    We present a simple analytical model that describes the injection current and temperature dependence of optical feedback interferometry signal strength for a single-mode laser diode. The model is derived from the Lang and Kobayashi rate equations, and is developed both for signals acquired from the monitoring photodiode (proportional to the variations in optical power) and for those obtained by amplification of the corresponding variations in laser voltage. The model shows that both the photodiode and the voltage signal strengths are dependent on the laser slope efficiency, which itself is a function of the injection current and the temperature. Moreover, the model predicts that the photodiode and voltage signal strengths depend differently on injection current and temperature. This important model prediction was proven experimentally for a near-infrared distributed feedback laser by measuring both types of signals over a wide range of injection currents and temperatures. Therefore, this simple model provides important insight into the radically different biasing strategies required to achieve optimal sensor sensitivity for both interferometric signal acquisition schemes.

  2. Over-injection and self-oscillations in an electron vacuum diode

    NASA Astrophysics Data System (ADS)

    Leopold, J. G.; Siman-Tov, M.; Goldman, A.; Krasik, Ya. E.

    2017-07-01

    We demonstrate a practical means by which one can inject more than the space-charge limiting current into a vacuum diode. This over-injection causes self-oscillations of the space-charge resulting in an electron beam current modulation at a fixed frequency, a reaction of the system to the Coulomb repulsive forces due to charge accumulation.

  3. Experiments Using Local Helicity Injectors in the Lower Divertor Region as the Majority Current Drive in a Tokamak Plasma

    NASA Astrophysics Data System (ADS)

    Perry, Justin M.

    Local helicity injection (LHI) is a non-solenoidal current drive capable of achieving high-Ip tokamak startup with a relatively compact and non-invasive array of current injectors in the plasma scrape-off layer. The choice of injector location within the edge region is flexible, but has a profound influence on the nature of the current drive in LHI discharges. Past experiments on the Pegasus ST with injection on the low-field-side near the outboard midplane produced plasmas dominated by inductive drive resulting primarily from plasma geometry evolution over the discharge. Recent experiments with injection on the high-field- side in the lower divertor region produce plasmas dominated by helicity injection current drive, with relatively static plasma geometry, and thus negligible inductive drive. Plasma current up to 200 kA is driven with helicity injection as the dominant current drive using a pair of 4 cm2 area injectors sourcing 8 kA of total injected current. Steady sustainment with LHI current drive alone is demonstrated, with 100 kA sustained for 18 ms. Maximum achievable plasma current is found to scale approximately linearly with a plasma-geometry- normalized form of the effective loop voltage from LHI, Vnorm = AinjVinj/Rinj, where A inj is the total injector area, Vinj is the injector bias voltage, and Rinj is the major radius of the injectors. A newly-discovered MHD regime for LHI-driven plasmas is described, in which the large-amplitude n = 1 fluctuations at 20-50 kHz which are generally dominant during LHI are abruptly reduced by an order of magnitude on the outboard side. High frequency fluctuations ( f > 400 kHz) increase inside the plasma edge at the same time. This regime results in improved plasma current and pervasive changes to plasma behavior, and may suggest short wavelength turbulence as a current drive mechanism during LHI.

  4. Intensity dynamics in a waveguide array laser

    NASA Astrophysics Data System (ADS)

    Feng, Mingming; Williams, Matthew O.; Kutz, J. Nathan; Silverman, Kevin L.; Mirin, Richard P.; Cundiff, Steven T.

    2011-02-01

    We consider experimentally and theoretically the optical field dynamics of a five-emitter laser array subject to a ramped injection current. We have achieved experimentally an array that produces a robust oscillatory power output with a nearly constant π phase shift between the oscillations from each waveguide. The output power also decreases linearly as a function of waveguide number. Those behaviors persisted for pump currents varying between 380 and 500 mA with only a slight change in phase. Of note is the fact that the fundamental frequency of oscillation increases with injection current, and higher harmonics are produced above a threshold current of approximately 380 mA. Experimental observations and theoretical predictions are in agreement. A low dimensional model was also developed and the impact of the nonuniform injection current studied. A nonuniform injection current is capable of shifting the bifurcations of the waveguide array providing a valuable method of array tuning without additional gain or structural alterations to the array.

  5. SAPS/SAID revisited: A causal relation to the substorm current wedge

    NASA Astrophysics Data System (ADS)

    Mishin, Evgeny; Nishimura, Yukitoshi; Foster, John

    2017-08-01

    We present multispacecraft observations of enhanced flow/electric field channels in the inner magnetosphere and conjugate subauroral ionosphere, i.e., subauroral polarization streams (SAPS) near dusk and subauroral ion drifts (SAID) near midnight. The channels collocate with ring current (RC) injections lagging the onset of substorms by a few to ˜20 min, i.e., significantly shorter than the gradient-curvature drift time of tens of keV ions. The time lag is of the order of the propagation time of reconnection-injected hot plasma jets to the premidnight plasmasphere and the substorm current wedge (SCW) to dusk. The observations confirm and expand on the previous results on the SAID features that negate the paradigm of voltage and current generators. Fast-time duskside SAPS/RC injections appear intimately related to a two-loop circuit of the substorm current wedge (SCW2L). We suggest that the poleward electric field inherent in the SCW2L circuit, which demands closure of the Region 1 and Region 2 sense field-aligned currents via meridional currents, is the ultimate cause of fast RC injections and SAPS on the duskside.

  6. SAID/SAPS Revisited: A Causal Relation to the Substorm Current Wedge

    NASA Astrophysics Data System (ADS)

    Mishin, E. V.

    2017-12-01

    We present multi-spacecraft observations of enhanced flow/electric field channels in the inner magnetosphere and conjugate subauroral ionosphere, i.e., subauroral polarization streams (SAPS) near dusk and subauroral ion drifts (SAID) near midnight. The channels collocate with ring current (RC) injections lagging the onset of substorms by a few to ˜20 minutes, i.e., significantly shorter than the gradient-curvature drift time of tens of keV ions. The time lag is of the order of the propagation time of reconnection-injected hot plasma jets to the premidnight plasmasphere and the substorm current wedge (SCW) to dusk. The observations confirm and expand on the previous results on the SAID features that negate the paradigm of voltage and current generators. Fast-time duskside SAPS/RC injections appear intimately related to a two-loop circuit of the substorm current wedge (SCW2L). We suggest that the poleward electric field inherent in the SCW2L circuit, which demands closure of the Region 1- and Region 2-sense field-aligned currents via meridional currents, is the ultimate cause of fast RC injections and SAPS on the duskside.

  7. Non-Solenoidal Tokamak Startup via Inboard Local Helicity Injection on the Pegasus ST

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Barr, J. L.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Pachicano, J. L.; Reusch, J. A.; Rodriguez Sanchez, C.; Richner, N. J.; Schlossberg, D. J.

    2016-10-01

    Local helicity injection (LHI) is a non-solenoidal startup technique utilizing small injectors at the plasma edge to source current along helical magnetic field lines. Unstable injected current streams relax to a tokamak-like configuration with high toroidal current multiplication. Flexible placement of injectors permits tradeoffs between helicity injection rate, poloidal field induction, and magnetic geometry requirements for initial relaxation. Experiments using a new set of large-area injectors in the lower divertor explore the efficacy of high-field-side (HFS) injection. The increased area (4 cm2) current source is functional up to full Pegasus toroidal field (BT , inj = 0.23 T). However, relaxation to a tokamak state is increasingly frustrated for BT , inj > 0.15 T with uniform vacuum vertical field. Paths to relaxation at increased field include: manipulation of vacuum poloidal field geometry; increased injector current; and plasma initiation with outboard injectors, subsequently transitioning to divertor injector drive. During initial tests of HFS injectors, achieved Vinj was limited to 600 V by plasma-material interactions on the divertor plate, which may be mitigated by increasing injector elevation. In experiments with helicity injection as the dominant current drive Ip 0.13 MA has been attained, with T̲e > 100 eV and ne 1019 m-3. Extrapolation to full BT, longer pulse length, and Vinj 1 kV suggest Ip > 0.25 MA should be attainable in a plasma dominated by helicity drive. Work supported by US DOE Grant DE-FG02-96ER54375.

  8. Effectiveness of Shield Termination Techniques Tested with TEM Cell and Bulk Current Injection

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Hare, Richard J.

    2009-01-01

    This paper presents experimental results of the effectiveness of various shield termination techniques. Each termination technique is evaluated by two independent noise injection methods; transverse electromagnetic (TEM) cell operated from 3 MHz 400 MHz, and bulk current injection (BCI) operated from 50 kHz 400 MHz. Both single carrier and broadband injection tests were investigated. Recommendations as to how to achieve the best shield transfer impedance (i.e. reduced coupled noise) are made based on the empirical data. Finally, the noise injection techniques themselves are indirectly evaluated by comparing the results obtained from the TEM Cell to those from BCI.

  9. Local Helicity Injection Systems for Non-solenoidal Startup in the PEGASUS Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Redd, A. J.

    2013-10-01

    Local helicity injection is being developed in the PEGASUS Toroidal Experiment for non-solenoidal startup in spherical tokamaks. The effective loop voltage due to helicity injection scales with the area of the injectors, requiring the development of electron current injectors with areas much larger than the 2 cm2 plasma arc injectors used to date. Solid and gas-effused metallic electrodes were found to be unusable due to reduced injector area utilization from localized cathode spots and narrow operational regimes. An integrated array of 8 compact plasma arc sources is thus being developed for high current startup. It employs two monolithic power systems, for the plasma arc sources and the bias current extraction system. The array effectively eliminates impurity fueling from plasma-material interaction by incorporating a local scraper-limiter and conical-frustum bias electrodes to mitigate the effects of cathode spots. An energy balance model of helicity injection indicates that the resulting 20 cm2 of total injection area should provide sufficient current drive to reach 0.3 MA. At that level, helicity injection drive exceeds that from poloidal induction, which is the relevant operational regime for large-scale spherical tokamaks. Future placement of the injector array near an expanded boundary divertor region will test simultaneous optimization of helicity drive and the Taylor relaxation current limit. Work supported by US DOE Grant DE-FG02-96ER54375.

  10. Breast EIT using a new projected image reconstruction method with multi-frequency measurements.

    PubMed

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-05-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.

  11. Load flows and faults considering dc current injections

    NASA Technical Reports Server (NTRS)

    Kusic, G. L.; Beach, R. F.

    1991-01-01

    The authors present novel methods for incorporating current injection sources into dc power flow computations and determining network fault currents when electronic devices limit fault currents. Combinations of current and voltage sources into a single network are considered in a general formulation. An example of relay coordination is presented. The present study is pertinent to the development of the Space Station Freedom electrical generation, transmission, and distribution system.

  12. Overview of the Helicity Injected Torus (HIT) Program

    NASA Astrophysics Data System (ADS)

    Redd, A. J.; Jarboe, T. R.; Hamp, W. T.; Nelson, B. A.; O'Neill, R. G.; Sieck, P. E.; Smith, R. J.; Sutphin, G. L.; Wrobel, J. S.

    2007-06-01

    The Helicity Injected Torus with Steady Inductive Helicity Injection (HIT-SI) consists of a "bowtie"-shaped axisymmetric confinement region, with two half-torus helicity injectors mounted on each side of the axisymmetric flux conserver [Sieck et al, IEEE Trans. Plasma Sci., v.33, p.723 (2005); Jarboe, Fusion Technology, v.36, p.85 (1999)]. Current and flux are driven sinusoidally with time in each injector, with the goal of generating and sustaining an axisymmetric spheromak in the main confinement region. Improvements in machine conditioning have enabled systematic study of HIT-SI discharges with significant toroidal current ITOR, including cases in which this current ITOR switches sign one or more times during the discharge. Statistical studies of all HIT-SI discharges to date demonstrate a minimum injected power to form significant ITOR, and that the maximum ITOR scales approximately linearly with the total injected power.

  13. BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G.M.; Shaftan; T.

    2011-03-28

    Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used tomore » measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.« less

  14. Injection-insensitive lateral divergence in broad-area diode lasers achieved by spatial current modulation

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Tong, Cunzhu; Wang, Lijie; Zeng, Yugang; Tian, Sicong; Shu, Shili; Zhang, Jian; Wang, Lijun

    2016-11-01

    High-power broad-area (BA) diode lasers often suffer from low beam quality, broad linewidth, and a widened slow-axis far field with increasing current. In this paper, a two-dimensional current-modulated structure is proposed and it is demonstrated that it can reduce not only the far-field sensitivity to the injection current but also the linewidth of the lasing spectra. Injection-insensitive lateral divergence was realized, and the beam parameter product (BPP) was improved by 36.5%. At the same time, the linewidth was decreased by about 45% without significant degradations of emission power and conversion efficiency.

  15. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, James G.; Daily, William D.

    1994-01-01

    A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  16. Coherent Control of Nanoscale Ballistic Currents in Transition Metal Dichalcogenide ReS2.

    PubMed

    Cui, Qiannan; Zhao, Hui

    2015-04-28

    Transition metal dichalcogenides are predicted to outperform traditional semiconductors in ballistic devices with nanoscale channel lengths. So far, experimental studies on charge transport in transition metal dichalcogenides are limited to the diffusive regime. Here we show, using ReS2 as an example, all-optical injection, detection, and coherent control of ballistic currents. By utilizing quantum interference between one-photon and two-photon interband transition pathways, ballistic currents are injected in ReS2 thin film samples by a pair of femtosecond laser pulses. We find that the current decays on an ultrafast time scale, resulting in an electron transport of only a fraction of one nanometer. Following the relaxation of the initially injected momentum, backward motion of the electrons for about 1 ps is observed, driven by the Coulomb force from the oppositely moved holes. We also show that the injected current can be controlled by the phase of the laser pulses. These results demonstrate a new platform to study ballistic transport of nonequilibrium carriers in transition metal dichalcogenides.

  17. Software Toolbox for Low-Frequency Conductivity and Current Density Imaging Using MRI.

    PubMed

    Sajib, Saurav Z K; Katoch, Nitish; Kim, Hyung Joong; Kwon, Oh In; Woo, Eung Je

    2017-11-01

    Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes. Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes.

  18. Turning Noise into Signal: Utilizing Impressed Pipeline Currents for EM Exploration

    NASA Astrophysics Data System (ADS)

    Lindau, Tobias; Becken, Michael

    2017-04-01

    Impressed Current Cathodic Protection (ICCP) systems are extensively used for the protection of central Europe's dense network of oil-, gas- and water pipelines against destruction by electrochemical corrosion. While ICCP systems usually provide protection by injecting a DC current into the pipeline, mandatory pipeline integrity surveys demand a periodical switching of the current. Consequently, the resulting time varying pipe currents induce secondary electric- and magnetic fields in the surrounding earth. While these fields are usually considered to be unwanted cultural noise in electromagnetic exploration, this work aims at utilizing the fields generated by the ICCP system for determining the electrical resistivity of the subsurface. The fundamental period of the switching cycles typically amounts to 15 seconds in Germany and thereby roughly corresponds to periods used in controlled source EM applications (CSEM). For detailed studies we chose an approximately 30km long pipeline segment near Herford, Germany as a test site. The segment is located close to the southern margin of the Lower Saxony Basin (LSB) and part of a larger gas pipeline composed of multiple segments. The current injected into the pipeline segment originates in a rectified 50Hz AC signal which is periodically switched on and off. In contrast to the usual dipole sources used in CSEM surveys, the current distribution along the pipeline is unknown and expected to be non-uniform due to coating defects that cause current to leak into the surrounding soil. However, an accurate current distribution is needed to model the fields generated by the pipeline source. We measured the magnetic fields at several locations above the pipeline and used Biot-Savarts-Law to estimate the currents decay function. The resulting frequency dependent current distribution shows a current decay away from the injection point as well as a frequency dependent phase shift which is increasing with distance from the injection point. Electric field data were recorded at 45 stations located in an area of about 60 square kilometers in the vicinity to the pipeline. Additionally, the injected source current was recorded directly at the injection point. Transfer functions between the local electric fields and the injected source current are estimated for frequencies ranging from 0.03Hz to 15Hz using robust time series processing techniques. The resulting transfer functions are inverted for a 3D conductivity model of the subsurface using an elaborate pipeline model. We interpret the model with regards to the local geologic setting, demonstrating the methods capabilities to image the subsurface.

  19. Slit injection device

    DOEpatents

    Alger, Terry W.; Schlitt, Leland G.; Bradley, Laird P.

    1976-06-15

    A laser cavity electron beam injection device provided with a single elongated slit window for passing a suitably shaped electron beam and means for varying the current density of the injected electron beam.

  20. Fabrication and characteristics of excellent current spreading GaN-based LED by using transparent electrode-insulator-semiconductor structure

    NASA Astrophysics Data System (ADS)

    Qi, Chenglin; Huang, Yang; Zhan, Teng; Wang, Qinjin; Yi, Xiaoyan; Liu, Zhiqiang

    2017-08-01

    GaN-based vertical light-emitting-diodes (V-LEDs) with an improved current injection pattern were fabricated and a novel current injection pattern of LEDs which consists of electrode-insulator-semiconductor (EIS) structure was proposed. The EIS structure was achieved by an insulator layer (20-nm Ta2O5) deposited between the p-GaN and the ITO layer. This kind of EIS structure works through a defect-assisted tunneling mechanism to realize current injection and obtains a uniform current distribution on the chip surface, thus greatly improving the current spreading ability of LEDs. The appearance of this novel current injection pattern of V-LEDs will subvert the impression of the conventional LEDs structure, including simplifying the chip manufacture technology and reducing the chip cost. Under a current density of 2, 5, 10, and 25 A/cm2, the luminous uniformity was better than conventional structure LEDs. The standard deviation of power density distribution in light distribution was 0.028, which was much smaller than that of conventional structure LEDs and illustrated a huge advantage on the current spreading ability of EIS-LEDs. Project supported by the Natural Science Foundation of China (Nos. 61306051, 61306050) and the National High Technology Program of China (No. 2014AA032606).

  1. Anthropometric Source Book. Volume 2: A Handbook of Anthropometric Data

    DTIC Science & Technology

    1978-07-01

    a.mw* % A W " " -I4 0-4DB~M’a~P Z.=22014 MO ZW=O𔃾WW4L" 0 "OBCOO&WWOWWBAB z z 34 " 14 0-44 BBP o z:.~Bwz 1 Wz0 V1O󈧵 j =P.’)ON- 01-0 e e o 0 t...4 c: P) POP~f pol IV)~) ~ P)V) t) PFrW)WW))m x dCY4 0- -a I.- - 0 ~ ItTt t: 1 1 % t’Q.4 O’*t%if! N D Dc ! 4 1Dff~ ffa ul In .4 NV4 W v4 q4v4 v4 NUM

  2. Bioactive Components of the Traditionally used Mushroom Podaxis pistillaris

    PubMed Central

    Al-Fatimi, M. A. A.; Jülich, W.-D.; Jansen, R.; Lindequist, U.

    2006-01-01

    In the course of an ethnobotanical study on fungi used in Yemeni ethnomedicine the fungus Podaxis pistillaris (Podaxales, Podaxaceae, Basidiomycetes) was found to exhibit antibacterial activity against Staphylococcus aureus, Micrococcus flavus, Bacillus subtilis, Proteus mirabilis, Serratia marcescens and Escherichia coli. In the culture medium of P. pistillaris three epidithiodiketopiperazines were identified by activity-guided isolation. Based on spectral data (NMR, ESI-MS and DCI-MS) their identity was established as epicorazine A (1), epicorazine B (2) and epicorazine C (3, antibiotic F 3822), which have not been reported as constituents of P. pistillaris previously. It is assumed that the identified compounds contribute to the antibacterial activity of the extract. PMID:16550228

  3. Transient Response in a Dendritic Neuron Model for Current Injected at One Branch

    PubMed Central

    Rinzel, John; Rall, Wilfrid

    1974-01-01

    Mathematical expressions are obtained for the response function corresponding to an instantaneous pulse of current injected to a single dendritic branch in a branched dendritic neuron model. The theoretical model assumes passive membrane properties and the equivalent cylinder constraint on branch diameters. The response function when used in a convolution formula enables one to compute the voltage transient at any specified point in the dendritic tree for an arbitrary current injection at a given input location. A particular numerical example, for a brief current injection at a branch terminal, illustrates the attenuation and delay characteristics of the depolarization peak as it spreads throughout the neuron model. In contrast to the severe attenuation of voltage transients from branch input sites to the soma, the fraction of total input charge actually delivered to the soma and other trees is calculated to be about one-half. This fraction is independent of the input time course. Other numerical examples, which compare a branch terminal input site with a soma input site, demonstrate that, for a given transient current injection, the peak depolarization is not proportional to the input resistance at the injection site and, for a given synaptic conductance transient, the effective synaptic driving potential can be significantly reduced, resulting in less synaptic current flow and charge, for a branch input site. Also, for the synaptic case, the two inputs are compared on the basis of the excitatory post-synaptic potential (EPSP) seen at the soma and the total charge delivered to the soma. PMID:4424185

  4. Transitions from injecting to non-injecting drug use: potential protection against HCV infection

    PubMed Central

    Des Jarlais, Don C.; McKnight, Courtney; Arasteh, Kamyar; Feelemyer, Jonathan; Perlman, David C.; Hagan, Holly; Cooper, Hannah L. F.

    2013-01-01

    Transitions from injecting to non-injecting drug use have been reported from many different areas, particularly in areas with large human immunodeficiency virus (HIV) epidemics. The extent to which such transitions actually protect against HIV and HCV has not been determined. A cross-sectional survey with HIV and hepatitis C (HCV) testing was conducted with 322 former injectors (persons who had injected illicit drugs but permanently transitioned to non-injecting use) and 801 current injectors recruited in New York City between 2007 and 2012. There were no differences in HIV prevalence, while HCV prevalence was significantly lower among former injectors compared to current injectors. Years injecting functioned as a mediating variable linking former injector status to lower HCV prevalence. Transitions have continued well beyond the reduction in the threat of AIDS to injectors in the city. New interventions to support transitions to non-injecting drug use should be developed and supported by both drug treatment and syringe exchange programs. PMID:24161262

  5. Antigen injection (image)

    MedlinePlus

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  6. Spheromak Formation and Current Sustainment Using a Repetitively Pulsed Source

    NASA Astrophysics Data System (ADS)

    Woodruff, S.; Macnab, A. I. D.; Ziemba, T. M.; Miller, K. E.

    2009-06-01

    By repeated injection of magnetic helicity ( K = 2φψ) on time-scales short compared with the dissipation time (τinj << τ K ), it is possible to produce toroidal currents relevant to POP-level experiments. Here we discuss an effective injection rate, due to the expansion of a series of current sheets and their subsequent reconnection to form spheromaks and compression into a copper flux-conserving chamber. The benefits of repeated injection are that the usual limits to current amplification can be exceeded, and an efficient quasi-steady sustainment scenario is possible (within minimum impact on confinement). A new experiment designed to address the physics of pulsed formation and sustainment is described.

  7. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, J.G.; Daily, W.D.

    1994-07-05

    A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  8. Dependences of contraction/expansion of stacking faults on temperature and current density in 4H-SiC p–i–n diodes

    NASA Astrophysics Data System (ADS)

    Okada, Aoi; Nishio, Johji; Iijima, Ryosuke; Ota, Chiharu; Goryu, Akihiro; Miyazato, Masaki; Ryo, Mina; Shinohe, Takashi; Miyajima, Masaaki; Kato, Tomohisa; Yonezawa, Yoshiyuki; Okumura, Hajime

    2018-06-01

    To investigate the mechanism of contraction/expansion behavior of Shockley stacking faults (SSFs) in 4H-SiC p–i–n diodes, the dependences of the SSF behavior on temperature and injection current density were investigated by electroluminescence image observation. We investigated the dependences of both triangle- and bar-shaped SSFs on the injection current density at four temperature levels. All SSFs in this study show similar temperature and injection current density dependences. We found that the expansion of SSFs at a high current density was converted to contraction at a certain value as the current decreased and that the value is temperature-dependent. It has been confirmed that SSF behavior, which was considered complex or peculiar, might be explained mainly by the energy change caused by SSFs.

  9. Class I Underground Injection Control Program: Study of the Risks Associated with Class I Underground Injection Wells

    EPA Pesticide Factsheets

    The document provides describes the current Class I UIC program, the history of Class I injection, and studies of human health risks associated with Class I injection wells, which were conducted for past regulatory efforts and policy documentation.

  10. Non-solenoidal Startup with High-Field-Side Local Helicity Injection on the Pegasus ST

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Bodner, G. M.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Pachicano, J. L.; Pierren, C.; Richner, N. J.; Rodriguez Sanchez, C.; Schlossberg, D. J.; Reusch, J. A.; Weberski, J. D.

    2017-10-01

    Local Helicity Injection (LHI) is a non-solenoidal startup technique utilizing electron current injectors at the plasma edge to initiate a tokamak-like plasma at high Ip . Recent experiments on Pegasus explore the inherent tradeoffs between high-field-side (HFS) injection in the lower divertor region and low-field-side (LFS) injection at the outboard midplane. Trade-offs include the relative current drive contributions of HI and poloidal induction, and the magnetic geometry required for relaxation to a tokamak-like state. HFS injection using a set of two increased-area injectors (Ainj = 4 cm2, Vinj 1.5 kV, and Iinj 8 kA) in the lower divertor is demonstrated over the full range of toroidal field available on Pegasus (BT 0 <= 0.15 T). Increased PMI on both the injectors and the lower divertor plates was observed during HFS injection, and was substantively mitigated through optimization of injector geometry and placement of local limiters to reduce scrape-off density in the divertor region. Ip up to 200 kA is achieved with LHI as the dominant current drive, consistent with expectations from helicity balance. To date, experiments support Ip increasing linearly with helicity injection rate. The high normalized current (IN >= 10) attainable with LHI and the favorable stability of the ultra-low aspect ratio, low-li LHI-driven plasmas allow access to high βt-up to 100 % , as indicated by kinetically-constrained equilibrium reconstructions. Work supported by US DOE Grant DE-FG02-96ER54375.

  11. The Helicity Injected Torus (HIT) Program

    NASA Astrophysics Data System (ADS)

    Jarboe, T. R.; Gu, P.; Hamp, W.; Izzo, V.; Jewell, P.; Liptac, J.; McCollam, K. J.; Nelson, B. A.; Raman, R.; Redd, A. J.; Shumlak, U.; Sieck, P. E.; Smith, R. J.; Jain, K. K.; Nagata, M.; Uyama, T.

    2000-10-01

    The purpose of the Helicity Injected Torus (HIT) program is to develop current drive techniques for low-aspect-ratio toroidal plasmas. The present HIT-II spherical tokamak experiment is capable of both Coaxial Helicity Injection (CHI) and transformer action current drive. The HIT-II device itself is modestly sized (major radius R = 0.3 m, minor radius a = 0.2 m, with an on-axis magnetic field of up to Bo = 0.5 T), but has demonstrated toroidal plasma currents of up to 200 kA, using either CHI or transformer drive. An overview of ongoing research on HIT-II plasmas, including recent results, will be presented. An electron-locking model has been developed for helicity injection current drive; a description of this model will be presented, as well as comparisons to experimental results from the HIT and HIT-II devices. Empirical results from both the HIT program and past spheromak research, buttressed by theoretical developments, have led to the design of the upcoming HIT-SI (Helicity Injected Torus with Steady Inductive helicity injection) device (T.R. Jarboe, Fusion Technology 36, p. 85, 1999). HIT-SI will be able to form a high-beta spheromak, a low aspect ratio RFP or a spherical tokamak using constant inductive helicity injection. The HIT-SI design and construction progress will be presented.

  12. Patient preference for a new growth hormone injection device: results of an open-label study in Japanese pediatric patients.

    PubMed

    Kappelgaard, Anne-Marie; Mikkelsen, Søren; Knudsen, Thomas Kamp; Fuchs, Gitte Schøning

    2011-01-01

    Growth hormone deficiency (GHD) in children is treated with daily subcutaneous injections of GH. Poor adherence, resulting in suboptimal treatment outcomes, is common due to long-term treatment. Injection devices that are considered easy to use by patients or guardians could improve adherence. This study assessed the usability of the Norditropin FlexPro pen injector and NovoTwist needles (both Novo Nordisk A/S, Bagsvaerd, Denmark) in Japanese children and adolescents with GHD. This open-label, uncontrolled usability test included patients aged 6 to < or = 18 years with GHD currently receiving daily injections of GH with pen injectors. Patients performed repeated injections of test medium into a foam cushion. Patients or guardians completed a questionnaire on pen handling. A total of 73/74 patients (99%) rated Norditropin FlexPro easy to handle, reporting no technical complaints. In total, 60 (81%) preferred Norditropin FlexPro over their current device, with 12% preferring their current device and 7% not sure. Norditropin FlexPro was perceived as easy to use and reliable, and was well accepted and preferred over the current device for the administration of GH in children and adolescents. Patients were more confident that Norditropin FlexPro delivered the right dose compared with their current device.

  13. Independent variations of applied voltage and injection current for controlling the quantum-confined Stark effect in an InGaN/GaN quantum-well light-emitting diode.

    PubMed

    Chen, Horng-Shyang; Liu, Zhan Hui; Shih, Pei-Ying; Su, Chia-Ying; Chen, Chih-Yen; Lin, Chun-Han; Yao, Yu-Feng; Kiang, Yean-Woei; Yang, C C

    2014-04-07

    A reverse-biased voltage is applied to either device in the vertical configuration of two light-emitting diodes (LEDs) grown on patterned and flat Si (110) substrates with weak and strong quantum-confined Stark effects (QCSEs), respectively, in the InGaN/GaN quantum wells for independently controlling the applied voltage across and the injection current into the p-i-n junction in the lateral configuration of LED operation. The results show that more carrier supply is needed in the LED of weaker QCSE to produce a carrier screening effect for balancing the potential tilt in increasing the forward-biased voltage, when compared with the LED of stronger QCSE. The small spectral shift range in increasing injection current in the LED of weaker QCSE is attributed not only to the weaker QCSE, but also to its smaller device resistance such that a given increment of applied voltage leads to a larger increment of injection current. From a viewpoint of practical application in LED operation, by applying a reverse-biased voltage in the vertical configuration, the applied voltage and injection current in the lateral configuration can be independently controlled by adjusting the vertical voltage for keeping the emission spectral peak fixed.

  14. Methods, systems and apparatus for optimization of third harmonic current injection in a multi-phase machine

    DOEpatents

    Gallegos-Lopez, Gabriel

    2012-10-02

    Methods, system and apparatus are provided for increasing voltage utilization in a five-phase vector controlled machine drive system that employs third harmonic current injection to increase torque and power output by a five-phase machine. To do so, a fundamental current angle of a fundamental current vector is optimized for each particular torque-speed of operating point of the five-phase machine.

  15. Electrical filtering in gerbil isolated type I semicircular canal hair cells

    NASA Technical Reports Server (NTRS)

    Rennie, K. J.; Ricci, A. J.; Correia, M. J.

    1996-01-01

    1. Membrane potential responses of dissociated gerbil type I semicircular canal hair cells to current injections in whole cell current-clamp have been measured. The input resistance of type I cells was 21.4 +/- 14.3 (SD) M omega, (n = 25). Around the zero-current potential (Vz = -66.6 +/- 9.3 mV, n = 25), pulsed current injections (from approximately -200 to 750 pA) produced only small-amplitude, pulse-like changes in membrane potential. 2. Injecting constant current to hyperpolarize the membrane to around -100 mV resulted in a approximately 10-fold increase in membrane resistance. Current pulses superimposed on this constant hyperpolarization produced larger and more complex membrane potential changes. Depolarizing currents > or = 200 pA caused a rapid transient peak voltage before a plateau. 3. Membrane voltage was able to faithfully follow sine-wave current injections around Vz over the range 1-1,000 Hz with < 25% attenuation at 1 kHz. A previously described K conductance, IKI, which is active at Vz, produces the low input resistance and frequency response. This was confirmed by pharmacologically blocking IKI. This conductance, present in type I cells but not type II hair cells, would appear to confer on type I cells a lower gain, but a much broader bandwidth at Vz, than seen in type II cells.

  16. Pain reduction and improvement of function following ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid in hip osteoarthritis.

    PubMed

    Araújo, J P; Silva, L; Andrade, R; Paços, M; Moreira, H; Migueis, N; Pereira, R; Sarmento, A; Pereira, H; Loureiro, N; Espregueira-Mendes, J

    2016-01-01

    The scientific literature has shown positive results regarding intra-articular injections of hyaluronic acid in osteoarthritic joints. When injecting in the hip joint, the guidance of ultrasound can provide higher injection accuracy and repeatability. However, due to the methodological limitations in the current available literature, its recommendation in the current practice is still controversial. This study shows that ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid can improve pain, function and quality of life in patients with symptomatic and radiographic hip osteoarthritis. In addition, the administration of triamcinolone hexacetonide and hyaluronic acid to the hip joint in these patients can delay the need for interventional surgery.

  17. Risk Behaviors, Prevalence of HIV and Hepatitis C Virus Infection and Population Size of Current Injection Drug Users in a China-Myanmar Border City: Results from a Respondent-Driven Sampling Survey in 2012

    PubMed Central

    Li, Lei; Assanangkornchai, Sawitri; Duo, Lin; McNeil, Edward; Li, Jianhua

    2014-01-01

    Background Injection drug use has been the major cause of HIV/AIDS in China in the past two decades. We measured the prevalences of HIV and hepatitis C virus (HCV) prevalence and their associated risk factors among current injection drug users (IDUs) in Ruili city, a border region connecting China with Myanmar that has been undergoing serious drug use and HIV spread problems. An estimate of the number of current IDUs is also presented. Methods In 2012, Chinese IDUs who had injected within the past six months and aged ≥18 years were recruited using a respondent-driven sampling (RDS) technique. Participants underwent interviews and serological testing for HIV, HBV, HCV and syphilis. Logistic regression indentified factors associated with HIV and HCV infections. Multiplier method was used to obtain an estimate of the size of the current IDU population via combining available service data and findings from our survey. Results Among 370 IDUs recruited, the prevalence of HIV and HCV was 18.3% and 41.5%, respectively. 27.1% of participants had shared a needle/syringe in their lifetime. Consistent condom use rates were low among both regular (6.8%) and non-regular (30.4%) partners. Factors independently associated with being HIV positive included HCV infection, having a longer history of injection drug use and experience of needle/syringe sharing. Participants with HCV infection were more likely to be HIV positive, have injected more types of drugs, have shared other injection equipments and have unprotected sex with regular sex partners. The estimated number of current IDUs in Ruili city was 2,714 (95% CI: 1,617–5,846). Conclusions IDUs may continue to be a critical subpopulation for transmission of HIV and other infections in this region because of the increasing population and persistent high risk of injection and sexual behaviours. Developing innovative strategies that can improve accessibility of current harm reduction services and incorporate more comprehensive contents is urgently needed. PMID:25203256

  18. A contoured gap coaxial plasma gun with injected plasma armature.

    PubMed

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  19. Brain iron metabolism and brain injury following subarachnoid hemorrhage: iCeFISH-pilot (CSF iron in SAH).

    PubMed

    Gomes, Joao A; Selim, Magdy; Cotleur, Anne; Hussain, M Shazam; Toth, Gabor; Koffman, Lauren; Asi, Khaled; Provencio, J Javier

    2014-10-01

    Iron-mediated oxidative damage has been implicated in the genesis of cerebral vasospasm in animal models of SAH. We sought to explore the relationship between levels of non-protein bound iron in cerebrospinal fluid and the development of brain injury in patients with aneurysmal SAH. Patients admitted with aneurysmal subarachnoid hemorrhage to a Neurointensive care unit of an academic, tertiary medical center, with Hunt and Hess grades 2-4 requiring ventriculostomy insertion as part of their clinical management were included in this pilot study. Samples of cerebrospinal fluid (CSF) were obtained on days 1, 3, and 5. A fluorometric assay that relies on an oxidation sensitive probe was used to measure unbound iron, and levels of iron-handling proteins were measured by means of enzyme-linked immunosorbent assays. We prospectively collected and recorded demographic, clinical, and radiological data. A total of 12 patients were included in this analysis. Median Hunt and Hess score on admission was 3.5 (IQR: 1) and median modified Fisher scale score was 4 (IQR: 1). Seven of 12 patients (58 %) developed delayed cerebral ischemia (DCI). Day 5 non-transferrin bound iron (NTBI) (7.88 ± 1 vs. 3.58 ± 0.8, p = 0.02) and mean NTBI (7.39 ± 0.4 vs. 3.34 + 0.4 p = 0.03) were significantly higher in patients who developed DCI. Mean redox-active iron, as well as day 3 levels of redox-active iron correlated with development of angiographic vasospasm in logistic regression analysis (p = 0.02); while mean redox-active iron and lower levels of ceruloplasmin on days 3, 5, and peak concentration were correlated with development of deep cerebral infarcts. Our preliminary data indicate a causal relationship between unbound iron and brain injury following SAH and suggest a possible protective role for ceruloplasmin in this setting, particularly in the prevention of cerebral ischemia. Further studies are needed to validate these findings and to probe their clinical significance.

  20. Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings.

    PubMed

    Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S

    2015-02-01

    The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia. © 2014 John Wiley & Sons Ltd.

  1. Persistence and diversity of directional landscape connectivity improves biomass pulsing in expanding and contracting wetlands

    USGS Publications Warehouse

    Yurek, Simeon; DeAngelis, Donald L.; Trexler, Joel C.; Klassen, Stephen; Larsen, Laurel G.

    2016-01-01

    In flood-pulsed ecosystems, hydrology and landscape structure mediate transfers of energy up the food chain by expanding and contracting in area, enabling spatial expansion and growth of fish populations during rising water levels, and subsequent concentration during the drying phase. Connectivity of flooded areas is dynamic as waters rise and fall, and is largely determined by landscape geomorphology and anisotropy. We developed a methodology for simulating fish dispersal and concentration on spatially-explicit, dynamic floodplain wetlands with pulsed food web dynamics, to evaluate how changes in connectivity through time contribute to the concentration of fish biomass that is essential for higher trophic levels. The model also tracks a connectivity index (DCI) over different compass directions to see if fish biomass dynamics can be related in a simple way to topographic pattern. We demonstrate the model for a seasonally flood-pulsed, oligotrophic system, the Everglades, where flow regimes have been greatly altered. Three dispersing populations of functional fish groups were simulated with empirically-based dispersal rules on two landscapes, and two twelve-year time series of managed water levels for those areas were applied. The topographies of the simulations represented intact and degraded ridge-and-slough landscapes (RSL). Simulation results showed large pulses of biomass concentration forming during the onset of the drying phase, when water levels were falling and fish began to converge into the sloughs. As water levels fell below the ridges, DCI declined over different directions, closing down dispersal lanes, and fish density spiked. Persistence of intermediate levels of connectivity on the intact RSL enabled persistent concentration events throughout the drying phase. The intact landscape also buffered effects of wet season population growth. Water level reversals on both landscapes negatively affected fish densities by depleting fish populations without allowing enough time for them to regenerate. Testable, spatiotemporal predictions of the timing, location, duration, and magnitude of fish concentration pulses were produced by the model, and can be applied to restoration planning.

  2. The Discovery Channel Telescope: Construction and Design Progress, June 2006

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Smith, B. W.; Millis, R. L.; Dunham, E. W.; Wiecha, O. M.; Marshall, H.

    2006-06-01

    The Discovery Channel Telescope (DCT) is a 4.2m telescope under construction in northern Arizona. The DCT is located at a new site near Happy Jack at 2361m elevation, which was selected following a lengthy site testing campaign that demonstrated median ground-level seeing of 0.84-arcsec FWHM. The DCT science mission includes targeted studies of astrophysical and solar system objects utilizing RC and Nasmyth-mounted imaging and spectroscopic instrumentation, and wide-field surveys of KBO’s, Centaurs, NEA’s, and other time-variable objects with a 2-degree FOV prime focus camera.The DCT facility enclosure and control building will be completed this year, including the supports for the telescope mount and dome, the major infrastructure for facility machinery, the instrument laboratory, control and computer rooms, and the auxiliary building for the mirror coating facility. Meanwhile, the 4.3m ULE meniscus primary mirror blank was completed at Corning, Inc., in October 2005, and the 2-3 year mirror figuring effort is due to begin June 2006. The primary mirror and its design support, and the preliminary integrated telescope mount model, were finite-element analyzed to optimize the design of the mirror and top-end support configurations. The prime focus camera design has been refined to achieve atmospheric dispersion-compensated 0.25-arcsec images at 1-degree field radius, from B to I-band, at reduced cost through simplification of glasses to standard types and utilization of spheres on all but two lens surfaces.The Discovery Channel Telescope is a project of the Lowell Observatory with major financial support from Discovery Communications, Inc. (DCI). DCI plans ongoing television programming featuring the construction of the telescope and the research ultimately conducted with the DCT. Lowell Observatory is actively seeking additional partners in the project; interested parties should contact R. L. Millis, Director.

  3. The Discovery Channel Telescope: Construction and Design Progress, January 2007

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Millis, R. L.; Smith, B. W.; Dunham, E. W.; Marshall, H.

    2006-12-01

    The Discovery Channel Telescope (DCT) is a 4.2m telescope under construction in northern Arizona. The DCT is located at a new site near Happy Jack at 2361m elevation, which was selected following a lengthy site testing campaign that demonstrated DIMM-characterized median ground-level seeing of 0.84-arcsec FWHM. The DCT science mission includes targeted studies of astrophysical and solar system objects utilizing RC and Nasmyth-mounted imaging and spectroscopic instrumentation, and wide-field surveys of KBO’s, NEA’s, and astrophysical objects with a 2-degree FOV prime focus camera. The DCT facility enclosure and control buildings will be completed soon, including the telescope mount and dome supports, major machinery infrastructure, the instrument laboratory, control and computer rooms, and the auxiliary building for the mirror coating plant. Meanwhile, the effort for final figuring and polishing of the 4.3m ULE meniscus primary mirror blank began in August 2006 at the University of Arizona College of Optical Sciences. The primary mirror and its design support, and the integrated telescope mount model, were finite-element analyzed to optimize the design of the mirror and top-end support configurations. The primary mirror axial and tangential actuators will be fabricated in early 2007 and utilized in the final figure and polish cycle. The prime focus camera design has been refined to achieve atmospheric dispersion-compensated 0.25-arcsec images at 1-degree field radius, from B to I-band, at reduced cost through simplification of glasses to standard types and utilization of spheres on all but two lens surfaces. The Discovery Channel Telescope is a project of the Lowell Observatory with major financial support from Discovery Communications, Inc. (DCI). DCI plans ongoing television programming featuring the construction of the telescope and the research ultimately conducted with the DCT. Lowell Observatory and Discovery Communications are actively seeking additional partners in the project; interested parties should contact R. L. Millis, Director.

  4. Polyuria and cerebral vasospasm after aneurysmal subarachnoid hemorrhage.

    PubMed

    Brown, Robert J; Epling, Brian P; Staff, Ilene; Fortunato, Gilbert; Grady, James J; McCullough, Louise D

    2015-10-13

    Natriuresis with polyuria is common after aneurysmal subarachnoid hemorrhage (aSAH). Previous studies have shown an increased risk of symptomatic cerebral vasospasm or delayed cerebral ischemia (DCI) in patients with hyponatremia and/or the cerebral salt wasting syndrome (CSW). However, natriuresis may occur in the absence of hyponatremia or hypovolemia and it is not known whether the increase in DCI in patients with CSW is secondary to a concomitant hypovolemia or because the physiology that predisposes to natriuretic peptide release also predisposes to cerebral vasospasm. Therefore, we investigated whether polyuria per se was associated with vasospasm and whether a temporal relationship existed. A retrospective review of patients with aSAH was performed. Exclusion criteria were admission more than 48 h after aneurysmal rupture, death within 5 days, and the development of diabetes insipidus or acute renal failure. Polyuria was defined as > 6 liters of urine in a 24 h period. Vasospasm was defined as a mean velocity > 120 m/s on Transcranial Doppler Ultrasonography (TCDs) or by evidence of vasospasm on computerized tomography (CT) or catheter angiography. Multivariable logistic regression was performed to assess the relationship between polyuria and vasospasm. 95 patients were included in the study. 51 had cerebral vasospasm and 63 met the definition of polyuria. Patients with polyuria were significantly more likely to have vasospasm (OR 4.301, 95% CI 1.378-13.419) in multivariate analysis. Polyuria was more common in younger patients (52 vs 68, p <.001) but did not impact mortality after controlling for age and disease severity. The timing of the development of polyuria was clustered around the diagnosis of vasospasm and patients with polyuria developed vasospasm faster than those without polyuria. Polyuria is common after aSAH and is significantly associated with cerebral vasospasm. The development of polyuria may be temporally related to the development of vasospasm. An increase in urine volume may be a useful clinical predictor of patients at risk for vasospasm.

  5. Epilithonimonas psychrotolerans sp. nov., isolated from alpine permafrost.

    PubMed

    Ge, Liang; Zhao, Qi; Sheng, Hongmei; Wu, Jianmin; An, Lizhe

    2015-11-01

    A bacterial strain, designated TSBY 57T, was isolated during a study on the phylogenetic diversity of culturable bacteria from alpine permafrost in Tianshan Mountains, China, and was classified by means of a polyphasic taxonomic approach. The novel strain was found to belong to the genus Epilithonimonas and was distinguished from recognized species of this genus. Strain TSBY 57T grew aerobically, at 0-30 °C, with 0-1.5% (w/v) NaCl and at pH 6-8.Cells were Gram-stain-negative, non-motile, non-spore-forming rods. Compared with the reference strains, the novel strain was psychrotolerant. The predominant fatty acids were summed feature 3 (consisting of C16:1ω7c and/or C16:1ω6c), anteiso-C15:0 and iso-C15:0.The sole respiratory quinone was MK-6.Phosphatidylethanolamine was predominant in the polar lipid profile of strain TSBY 57T. These chemotaxonomic traits were in good agreement with the characteristics of the genus Epilithonimonas. On the basis of 16S rRNA gene sequence similarity, strain TSBY 57T was a member of the genus Epilithonimonas and was closely related to Epilithonimonas tenax DSM 16811T (99.0%), Epilithonimonas ginsengisoli DCY78T (98.6%) and Epilithonimonas lactis H1T (98.5%). However, DNA-DNA reassociation values between strain TSBY 57T and E. tenax DSM 16811T, E. ginsengisoli DCY78T and E. lactis H1T were 39.5 ± 2.6, 37.7 ± 1.0 and 37.3 ± 1.1%, respectively. The G+C content of the DNA was 34.4 ± 0.2  mol%. Based on data from this polyphasic taxonomic study, strain TSBY 57T represents a novel species of the genus Epilithonimonas, for which the name Epilithonimonas psychrotolerans sp. nov. is proposed. The type strain is TSBY 57T ( = NRRL B-51307T=CCTCC AB 207182T).

  6. Tokamak startup using point-source dc helicity injection.

    PubMed

    Battaglia, D J; Bongard, M W; Fonck, R J; Redd, A J; Sontag, A C

    2009-06-05

    Startup of a 0.1 MA tokamak plasma is demonstrated on the ultralow aspect ratio Pegasus Toroidal Experiment using three localized, high-current density sources mounted near the outboard midplane. The injected open field current relaxes via helicity-conserving magnetic turbulence into a tokamaklike magnetic topology where the maximum sustained plasma current is determined by helicity balance and the requirements for magnetic relaxation.

  7. Can Steady Magnetospheric Convection Events Inject Plasma into the Ring Current?

    NASA Astrophysics Data System (ADS)

    Lemon, C.; Chen, M. W.; Guild, T. B.

    2009-12-01

    Steady Magnetospheric Convection (SMC) events are characterized by several-hour periods of enhanced convection that are devoid of substorm signatures. There has long been a debate about whether substorms are necessary to inject plasma into the ring current, or whether enhanced convection is sufficient. If ring current injections occur during SMC intervals, this would suggest that substorms are unnecessary. We use a combination of simulations and data observations to examine this topic. Our simulation model computes the energy-dependent plasma drift in a self-consistent electric and magnetic field, which allows us to accurately model the transport of plasma from the plasma sheet (where the plasma pressure is much larger than the magnetic pressure) into the inner magnetosphere (where plasma pressure is much less than the magnetic pressure). In regions where the two pressures are comparable (i.e. the inner plasma sheet), feedback between the plasma and magnetic field is critical for accurately modeling the physical evolution of the system. Our previous work has suggested that entropy losses in the plasma sheet (such as caused by substorms) may be necessary to inject a ring current. However, it is not yet clear whether other small-scale processes (e.g. bursty bulk flows) can provide sufficient entropy loss in the plasma sheet to allow for the penetration of plasma into the ring current. We combine our simulation results with data observations in order to better understand the physical processes required to inject a ring current.

  8. Corticosteroid and platelet-rich plasma injection therapy in tennis elbow (lateral epicondylalgia): a survey of current U.K. specialist practice and a call for clinical guidelines.

    PubMed

    Titchener, Andrew G; Booker, Simon J; Bhamber, Nivraj S; Tambe, Amol A; Clark, David I

    2015-11-01

    Tennis elbow is a common condition with a variety of treatment options, but little is known about which of these options specialists choose most commonly. Corticosteroid injections in tennis elbow may reduce pain in the short-term but delay long-term recovery. We have undertaken a UK-wide survey of upper limb specialists to assess current practice. Cross-sectional electronic survey of current members of the British Elbow and Shoulder Society (BESS) and the British Society for Surgery of the Hand (BSSH). 271 of 1047 eligible members responded (25.9%); consultant surgeons constituted the largest group (232/271, 85%). 131 respondents (48%) use corticosteroid injections as their first-line treatment for tennis elbow. 206 respondents (77%) believed that corticosteroid injections are not potentially harmful in the treatment of tennis elbow, while 31 (11%) did not use them in their current practice. In light of recent evidence of the potential harmful effects of corticosteroid therapy, 136 (50%) had not changed their practice while 108 (40.1%) had reduced or discontinued their use. 43 respondents (16%) reported having used platelet-rich plasma injections. Recent high-quality evidence that corticosteroids may delay recovery in tennis elbow appears to have had a limited effect on current practice. Treatment is not uniform among specialists and a proportion of them use platelet-rich plasma injections. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Efficient spin-current injection in single-molecule magnet junctions

    NASA Astrophysics Data System (ADS)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  10. Derivation of dynamo current drive in a closed-current volume and stable current sustainment in the HIT-SI experiment

    NASA Astrophysics Data System (ADS)

    Hossack, A. C.; Sutherland, D. A.; Jarboe, T. R.

    2017-02-01

    A derivation is given showing that the current inside a closed-current volume can be sustained against resistive dissipation by appropriately phased magnetic perturbations. Imposed-dynamo current drive theory is used to predict the toroidal current evolution in the helicity injected torus with steady inductive helicity injection (HIT-SI) experiment as a function of magnetic fluctuations at the edge. Analysis of magnetic fields from a HIT-SI discharge shows that the injector-imposed fluctuations are sufficient to sustain the measured toroidal current without instabilities whereas the small, plasma-generated magnetic fluctuations are not sufficiently large to sustain the current.

  11. Potential geographic "hotspots" for drug-injection related transmission of HIV and HCV and for initiation into injecting drug use in New York City, 2011-2015, with implications for the current opioid epidemic in the US.

    PubMed

    Des Jarlais, D C; Cooper, H L F; Arasteh, K; Feelemyer, J; McKnight, C; Ross, Z

    2018-01-01

    We identified potential geographic "hotspots" for drug-injecting transmission of HIV and hepatitis C virus (HCV) among persons who inject drugs (PWID) in New York City. The HIV epidemic among PWID is currently in an "end of the epidemic" stage, while HCV is in a continuing, high prevalence (> 50%) stage. We recruited 910 PWID entering Mount Sinai Beth Israel substance use treatment programs from 2011-2015. Structured interviews and HIV/ HCV testing were conducted. Residential ZIP codes were used as geographic units of analysis. Potential "hotspots" for HIV and HCV transmission were defined as 1) having relatively large numbers of PWID 2) having 2 or more HIV (or HCV) seropositive PWID reporting transmission risk-passing on used syringes to others, and 3) having 2 or more HIV (or HCV) seronegative PWID reporting acquisition risk-injecting with previously used needles/syringes. Hotspots for injecting drug use initiation were defined as ZIP codes with 5 or more persons who began injecting within the previous 6 years. Among PWID, 96% injected heroin, 81% male, 34% White, 15% African-American, 47% Latinx, mean age 40 (SD = 10), 7% HIV seropositive, 62% HCV seropositive. Participants resided in 234 ZIP codes. No ZIP codes were identified as potential hotspots due to small numbers of HIV seropositive PWID reporting transmission risk. Four ZIP codes were identified as potential hotspots for HCV transmission. 12 ZIP codes identified as hotspots for injecting drug use initiation. For HIV, the lack of potential hotspots is further validation of widespread effectiveness of efforts to reduce injecting-related HIV transmission. Injecting-related HIV transmission is likely to be a rare, random event. HCV prevention efforts should include focus on potential hotspots for transmission and on hotspots for initiation into injecting drug use. We consider application of methods for the current opioid epidemic in the US.

  12. DMA shared byte counters in a parallel computer

    DOEpatents

    Chen, Dong; Gara, Alan G.; Heidelberger, Philip; Vranas, Pavlos

    2010-04-06

    A parallel computer system is constructed as a network of interconnected compute nodes. Each of the compute nodes includes at least one processor, a memory and a DMA engine. The DMA engine includes a processor interface for interfacing with the at least one processor, DMA logic, a memory interface for interfacing with the memory, a DMA network interface for interfacing with the network, injection and reception byte counters, injection and reception FIFO metadata, and status registers and control registers. The injection FIFOs maintain memory locations of the injection FIFO metadata memory locations including its current head and tail, and the reception FIFOs maintain the reception FIFO metadata memory locations including its current head and tail. The injection byte counters and reception byte counters may be shared between messages.

  13. Room Temperature Electroluminescence from Tensile-Strained Si0.13Ge0.87/Ge Multiple Quantum Wells on a Ge Virtual Substrate

    PubMed Central

    Lin, Guangyang; Chen, Ningli; Zhang, Lu; Huang, Zhiwei; Huang, Wei; Wang, Jianyuan; Xu, Jianfang; Chen, Songyan; Li, Cheng

    2016-01-01

    Direct band electroluminescence (EL) from tensile-strained Si0.13Ge0.87/Ge multiple quantum wells (MQWs) on a Ge virtual substrate (VS) at room temperature is reported herein. Due to the competitive result of quantum confinement Stark effect and bandgap narrowing induced by tensile strain in Ge wells, electroluminescence from Γ1-HH1 transition in 12-nm Ge wells was observed at around 1550 nm. As injection current density increases, additional emission shoulders from Γ2-HH2 transition in Ge wells and Ge VS appeared at around 1300–1400 nm and 1600–1700 nm, respectively. The peak energy of EL shifted to the lower energy side superquadratically with an increase of injection current density as a result of the Joule heating effect. During the elevation of environmental temperature, EL intensity increased due to a reduction of energy between L and Γ valleys of Ge. Empirical fitting of the relationship between the integrated intensity of EL (L) and injection current density (J) with L~Jm shows that the m factor increased with injection current density, suggesting higher light emitting efficiency of the diode at larger injection current densities, which can be attributed to larger carrier occupations in the Γ valley and the heavy hole (HH) valance band at higher temperatures. PMID:28773923

  14. Room Temperature Electroluminescence from Tensile-Strained Si0.13Ge0.87/Ge Multiple Quantum Wells on a Ge Virtual Substrate.

    PubMed

    Lin, Guangyang; Chen, Ningli; Zhang, Lu; Huang, Zhiwei; Huang, Wei; Wang, Jianyuan; Xu, Jianfang; Chen, Songyan; Li, Cheng

    2016-09-27

    Direct band electroluminescence (EL) from tensile-strained Si 0.13 Ge 0.87 /Ge multiple quantum wells (MQWs) on a Ge virtual substrate (VS) at room temperature is reported herein. Due to the competitive result of quantum confinement Stark effect and bandgap narrowing induced by tensile strain in Ge wells, electroluminescence from Γ1-HH1 transition in 12-nm Ge wells was observed at around 1550 nm. As injection current density increases, additional emission shoulders from Γ2-HH2 transition in Ge wells and Ge VS appeared at around 1300-1400 nm and 1600-1700 nm, respectively. The peak energy of EL shifted to the lower energy side superquadratically with an increase of injection current density as a result of the Joule heating effect. During the elevation of environmental temperature, EL intensity increased due to a reduction of energy between L and Γ valleys of Ge. Empirical fitting of the relationship between the integrated intensity of EL ( L ) and injection current density ( J ) with L ~ J m shows that the m factor increased with injection current density, suggesting higher light emitting efficiency of the diode at larger injection current densities, which can be attributed to larger carrier occupations in the Γ valley and the heavy hole (HH) valance band at higher temperatures.

  15. Factors associated with pathways toward concurrent sex work and injection drug use among female sex workers who inject drugs in northern Mexico.

    PubMed

    Morris, Meghan D; Lemus, Hector; Wagner, Karla D; Martinez, Gustavo; Lozada, Remedios; Gómez, Rangel María Gudelia; Strathdee, Steffanie A

    2013-01-01

    To identify factors associated with time to initiation of (i) sex work prior to injecting drugs initiation; (ii) injection drug use prior to sex work initiation; and (iii) concurrent sex work and injection drug use (i.e. initiated at the same age) among female sex workers who currently inject drugs (FSW-IDU). Parametric survival analysis of baseline data for time to initiation event. Tijuana and Ciudad Juarez situated on the Mexico-US border. A total of 557 FSW-IDUs aged ≥18 years. Interview-administered surveys assessing context of sex work and injection drug use initiation. Nearly half (n = 258) initiated sex work prior to beginning to inject, a third (n = 163) initiated injection first and a quarter (n = 136) initiated both sex work and injection drug use concurrently. Low education and living in Ciudad Juarez accelerated time to sex work initiation. Being from a southern Mexican state and initiating drug use with inhalants delayed the time to first injection drug use. Having an intimate partner encourage entry into sex work and first injecting drugs to deal with depression accelerated time to initiating sex work and injection concurrently. Early physical abuse accelerated time to initiating sex work and injection, and substantially accelerated time to initiation of both behaviors concurrently. Among female sex workers who currently inject drugs in two Mexican-US border cities, nearly half appear to initiate sex work prior to beginning to inject, nearly one-third initiate injection drug use before beginning sex work and one-quarter initiate both behaviors concurrently. Predictors of these three trajectories differ, and this provides possible modifiable targets for prevention. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  16. Factors associated with pathways toward concurrent sex work and injection drug use among female sex workers who inject drugs in Northern Mexico

    PubMed Central

    Morris, Meghan D.; Lemus, Hector; Wagner, Karla D.; Martinez, Gustavo; Lozada, Remedios; Gómez, Rangel María Gudelia; Strathdee, Steffanie A.

    2012-01-01

    Aims To identify factors associated with time to initiation of (1) sex work prior to injecting drugs, (2) injection drug use, and (3) concurrent sex work and injection drug use (i.e., initiated at the same age) among female sex workers who currently inject drugs (FSW-IDU). Design Parametric survival analysis of baseline data for time to initiation event. Setting Tijuana and Ciudad Juarez situated on the Mexico-U.S. border. Participants 575 FSW-IDUs aged ≥18. Measurements Interview-administered surveys assessing context of sex work and injection drug use initiation. Findings Nearly half (n=256) initiated sex work prior to beginning to inject, a third (n=163) initiated injection first, and a quarter (n=136) initiated both sex work and injection drug use concurrently. Low education and living in Ciudad Juarez accelerated time to sex work initiation. Being from a southern Mexican state and initiating drug use with inhalants delayed the time to first injection drug use. Having an intimate partner encourage entry into sex work and first injecting drugs to deal with depression accelerated time to initiating sex work and injection concurrently. Early physical abuse accelerated time to initiating sex work and injection, and substantially accelerated time to initiation of both behaviors concurrently. Conclusions Among female sex workers who currently inject drugs in two Mexican-US border cities, nearly half appear to initiate sex work prior to beginning to inject, nearly one third initiate injection drug use before beginning sex work, and one quarter initiate both behaviors concurrently. Predictors of these three trajectories differ, and this provides possible modifiable targets for prevention. PMID:22775475

  17. A Proof of the Convexity of the Free Boundary for Porous Flow through a Rectangular Dam Using the Maximum Principle.

    DTIC Science & Technology

    1979-04-01

    di v a l u tat iv i n el la fisica— matematica , Accad. Naz. dci Lincel. 161—188(1975). fu LLER. K.: Barriers on cor.es for uniforalu elliptic...t ) — t ldt , (1.101 y and derived many properties of w . Further properties of w and u — y - ~~ have been obt .i i nod by C a f fa r el 11 t a...i ves art expa nsio n for t lit’ solution near t st-paid— t i O l l ~ o l n t C , and A it ch i s o n ( 1977) gives numer ica l solutions . R e c

  18. Transfer impedance measurements of the space shuttle Solid Rocket Motor (SRM) joints, wire meshes and a carbon graphite motor case

    NASA Technical Reports Server (NTRS)

    Papazian, Peter B.; Perala, Rodney A.; Curry, John D.; Lankford, Alan B.; Keller, J. David

    1988-01-01

    Using three different current injection methods and a simple voltage probe, transfer impedances for Solid Rocket Motor (SRM) joints, wire meshes, aluminum foil, Thorstrand and a graphite composite motor case were measured. In all cases, the surface current distribution for the particular current injection device was calculated analytically or by finite difference methods. The results of these calculations were used to generate a geometric factor which was the ratio of total injected current to surface current density. The results were validated in several ways. For wire mesh measurements, results showed good agreement with calculated results for a 14 by 18 Al screen. SRM joint impedances were independently verified. The filiment wound case measurement results were validated only to the extent that their curve shape agrees with the expected form of transfer impedance for a homogeneous slab excited by a plane wave source.

  19. Dark current in multilayer stabilized amorphous selenium based photoconductive x-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frey, Joel B.; Belev, George; Kasap, Safa O.

    2012-07-01

    We report on experimental results which show that the dark current in n-i-p structured, amorphous selenium films is independent of i-layer thickness in samples with consistently thick blocking layers. We have observed, however, a strong dependence on the n-layer thickness and positive contact metal chosen. These results indicate that the dominant source of the dark current is carrier injection from the contacts and any contribution from carriers thermally generated in the bulk of the photoconductive layer is negligible. This conclusion is supported by a description of the dark current transients at different applied fields by a model which assumes onlymore » carrier emission over a Schottky barrier. This model also predicts that while hole injection is initially dominant, some time after the application of the bias, electron injection may become the dominant source of dark current.« less

  20. Thermal quench mitigation and current quench control by injection of mixed species shattered pellets in DIII-D

    DOE PAGES

    Shiraki, D.; Commaux, N.; Baylor, L. R.; ...

    2016-06-27

    Injection of large shattered pellets composed of variable quantities of the main ion species (deuterium) and high-Z impurities (neon) in the DIII-D tokamak demonstrate control of thermal quench (TQ) and current quench (CQ) properties in mitigated disruptions. As the pellet composition is varied, TQ radiation fractions increase continuously with the quantity of radiating impurity in the pellet, with a corresponding decrease in divertor heating. Post-TQ plasma resistivities increase as a result of the higher radiation fraction, allowing control of current decay timescales based on the pellet composition. Magnetic reconstructions during the CQ show that control of the current decay ratemore » allows continuous variation of the minimum safety factor during the vertically unstable disruption, reducing the halo current fraction and resulting vessel displacement. Both TQ and CQ characteristics are observed to saturate at relatively low quantities of neon, indicating that effective mitigation of disruption loads by shattered pellet injection (SPI) can be achieved with modest impurity quantities, within injection quantities anticipated for ITER. In conclusion, this mixed species SPI technique provides apossible approach for tuning disruption properties to remain within the limited ranges allowed in the ITER design.« less

  1. Numerical Analysis of the Temperature Impact on Performance of GaN-Based 460-nm Light-Emitting Diode.

    PubMed

    Tawfik, Wael Z; Lee, June Key

    2018-03-01

    The influence of temperature on the characteristics of a GaN-based 460-nm light-emitting diode (LED) prepared on sapphire substrate was simulated using the SiLENSe and SpeCLED software programs. High temperatures impose negative effects on the performance of GaN-based LEDs. As the temperature increases, electrons acquire higher thermal energies, and therefore LEDs may suffer more from high-current loss mechanisms, which in turn causes a reduction in the radiative recombination rate in the active region. The internal quantum efficiency was reduced by about 24% at a current density of 35 A/cm2, and the electroluminescence spectral peak wavelength was redshifted. The LED operated at 260 K and exhibited its highest light output power of ~317.5 mW at a maximum injection current of 350 mA, compared to 212.2 mW for an LED operated at 400 K. However, increasing temperature does not cause a droop in efficiency under high injection conditions. The peak efficiency at 1 mA of injection current decreases more rapidly by ~15% with increasing temperature from 260 to 400 K than the efficiency at high injection current of 350 mA by ~11%.

  2. Thermal quench mitigation and current quench control by injection of mixed species shattered pellets in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraki, D.; Commaux, N.; Baylor, L. R.

    Injection of large shattered pellets composed of variable quantities of the main ion species (deuterium) and high-Z impurities (neon) in the DIII-D tokamak demonstrate control of thermal quench (TQ) and current quench (CQ) properties in mitigated disruptions. As the pellet composition is varied, TQ radiation fractions increase continuously with the quantity of radiating impurity in the pellet, with a corresponding decrease in divertor heating. Post-TQ plasma resistivities increase as a result of the higher radiation fraction, allowing control of current decay timescales based on the pellet composition. Magnetic reconstructions during the CQ show that control of the current decay ratemore » allows continuous variation of the minimum safety factor during the vertically unstable disruption, reducing the halo current fraction and resulting vessel displacement. Both TQ and CQ characteristics are observed to saturate at relatively low quantities of neon, indicating that effective mitigation of disruption loads by shattered pellet injection (SPI) can be achieved with modest impurity quantities, within injection quantities anticipated for ITER. In conclusion, this mixed species SPI technique provides apossible approach for tuning disruption properties to remain within the limited ranges allowed in the ITER design.« less

  3. Thermal quench mitigation and current quench control by injection of mixed species shattered pellets in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraki, D.; Commaux, N.; Baylor, L. R.

    Injection of large shattered pellets composed of variable quantities of the main ion species (deuterium) and high-Z impurities (neon) in the DIII-D tokamak demonstrates control of thermal quench (TQ) and current quench (CQ) properties in mitigated disruptions. As the pellet composition is varied, TQ radiation fractions increase continuously with the quantity of radiating impurity in the pellet, with a corresponding decrease in divertor heating. Post-TQ plasma resistivities increase as a result of the higher radiation fraction, allowing control of current decay timescales based on the pellet composition. Magnetic reconstructions during the CQ show that control of the current decay ratemore » allows continuous variation of the minimum safety factor during the vertically unstable disruption, reducing the halo current fraction and resulting vessel displacement. Both TQ and CQ characteristics are observed to saturate at relatively low quantities of neon, indicating that effective mitigation of disruption loads by shattered pellet injection (SPI) can be achieved with modest impurity quantities, within injection quantities anticipated for ITER. This mixed species SPI technique provides a possible approach for tuning disruption properties to remain within the limited ranges allowed in the ITER design.« less

  4. Current injection and transport in polyfluorene

    NASA Astrophysics Data System (ADS)

    Yang, Chieh-Kai; Yang, Chia-Ming; Liao, Hua-Hsien; Horng, Sheng-Fu; Meng, Hsin-Fei

    2007-08-01

    A comprehensive numerical model is established for the electrical processes in a sandwich organic semiconductor device with high carrier injection barrier. The charge injection at the anode interface with 0.8eV energy barrier is dominated by the hopping among the gap states of the semiconductor caused by disorders. The Ohmic behavior at low voltage is demonstrated to be not due to the background doping but the filaments formed by conductive clusters. In bipolar devices with low work function cathode it is shown that near the anode the electron traps significantly enhance hole injection through Fowler-Nordheim tunneling, resulting in rapid increases of the hole carrier and current in comparison with the hole-only devices.

  5. Plasma Sheet Injections into the Inner Magnetosphere: Two-way Coupled OpenGGCM-RCM model results

    NASA Astrophysics Data System (ADS)

    Raeder, J.; Cramer, W. D.; Toffoletto, F.; Gilson, M. L.; Hu, B.

    2017-12-01

    Plasma sheet injections associated with low flux tube entropy bubbles have been found to be the primary means of mass transport from the plasma sheet to the inner magnetosphere. A two-way coupled global magnetosphere-ring current model, where the magnetosphere is modeled by the OpenGGCM MHD model and the ring current is modeled by the Rice Convection Model (RCM), is used to determine the frequency of association of bubbles with injections and inward plasma transport, as well as typical injection characteristics. Multiple geomagnetic storms and quiet periods are simulated to track and characterize inward flow behavior. Dependence on geomagnetic activity levels or drivers is also examined.

  6. Analysis of the Electrohydrodynamic Flow in a Symmetric System of Electrodes by the Method of Dynamic Current-Voltage Characteristics

    NASA Astrophysics Data System (ADS)

    Stishkov, Yu. K.; Zakir'yanova, R. E.

    2018-04-01

    We have solved the problem of injection-type through electrohydrodynamic (EHD) flow in a closed channel. We have considered a model of a liquid with four types of ions. It is shown that a through EHD flow without internal vortices in the electrode gap is formed for the ratio 2 : 1 of the initial injection current from the electrodes in the channel. The structure of the flow in different parts of the channel and the integral characteristics of the flow have been analyzed. It is shown that for a quadratic function of injection at the electrodes, the current-voltage characteristic of the flow is also quadratic.

  7. Upregulation of cystathionine-β-synthetase expression contributes to inflammatory pain in rat temporomandibular joint

    PubMed Central

    2014-01-01

    Background Hydrogen sulfide (H2S), an endogenous gaseotransmitter/modulator, is becoming appreciated that it may be involved in a wide variety of processes including inflammation and nociception. However, the role for H2S in nociceptive processing in trigeminal ganglion (TG) neuron remains unknown. The aim of this study was designed to investigate whether endogenous H2S synthesizing enzyme cystathionine-β-synthetase (CBS) plays a role in inflammatory pain in temporomandibular joint (TMJ). Methods TMJ inflammatory pain was induced by injection of complete Freund’s adjuvant (CFA) into TMJ of adult male rats. Von Frey filaments were used to examine pain behavioral responses in rats following injection of CFA or normal saline (NS). Whole cell patch clamp recordings were employed on acutely isolated TG neurons from rats 2 days after CFA injection. Western blot analysis was carried out to measure protein expression in TGs. Results Injection of CFA into TMJ produced a time dependent hyperalgesia as evidenced by reduced escape threshold in rats responding to VFF stimulation. The reduced escape threshold was partially reversed by injection of O-(Carboxymethyl) hydroxylamine hemihydrochloride (AOAA), an inhibitor for CBS, in a dose-dependent manner. CFA injection led to a marked upregulation of CBS expression when compared with age-matched controls. CFA injection enhanced neuronal excitability as evidenced by depolarization of resting membrane potentials, reduction in rheobase, and an increase in number of action potentials evoked by 2 and 3 times rheobase current stimulation and by a ramp current stimulation of TG neurons innervating the TMJ area. CFA injection also led to a reduction of IK but not IA current density of TG neurons. Application of AOAA in TMJ area reduced the production of H2S in TGs and reversed the enhanced neural hyperexcitability and increased the IK currents of TG neurons. Conclusion These data together with our previous report indicate that endogenous H2S generating enzyme CBS plays an important role in TMJ inflammation, which is likely mediated by inhibition of IK currents, thus identifying a specific molecular mechanism underlying pain and sensitization in TMJ inflammation. PMID:24490955

  8. Surgical versus injection treatment for injection-confirmed chronic sacroiliac joint pain

    PubMed Central

    Spiker, William Ryan; Lawrence, Brandon D.; Raich, Annie L.; Skelly, Andrea C.; Brodke, Darrel S.

    2012-01-01

    Study design: Systematic review. Study rationale: Chronic sacroiliac joint pain (CSJP) is a common clinical entity with highly controversial treatment options. A recent systematic review compared surgery with denervation, but the current systematic review compares outcomes of surgical intervention with therapeutic injection for the treatment of CSJP and serves as the next step for evaluating current evidence on the comparative effectiveness of treatments for non-traumatic sacroiliac joint pain. Objective or clinical question: In adult patients with injection-confirmed CSJP, does surgical treatment lead to better outcomes and fewer complications than injection therapy? Methods: A systematic review of the English-language literature was undertaken for articles published between 1970 and June 2012. Electronic databases and reference lists of key articles were searched to identify studies evaluating surgery or injection treatment for injection-confirmed CSJP. Studies involving traumatic onset or non-injection–confirmed CSJP were excluded. Two independent reviewers assessed the level of evidence quality using the grading of recommendations assessment, development and evaluation (GRADE) system, and disagreements were resolved by consensus. Results: We identified twelve articles (seven surgical and five injection treatment) meeting our inclusion criteria. Regardless of the type of treatment, most studies reported over 40% improvement in pain as measured by Visual Analog Scale or Numeric rating Scale score. Regardless of the type of treatment, most studies reported over 20% improvement in functionality. Most complications were reported in the surgical studies. Conclusion: Surgical fusion and therapeutic injections can likely provide pain relief, improve quality of life, and improve work status. The comparative effectiveness of these interventions cannot be evaluated with the current literature. PMID:23526911

  9. Current profile redistribution driven by neutral beam injection in a reversed-field pinch

    NASA Astrophysics Data System (ADS)

    Parke, E.; Anderson, J. K.; Brower, D. L.; Den Hartog, D. J.; Ding, W. X.; Johnson, C. A.; Lin, L.

    2016-05-01

    Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q0 by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].

  10. Public Data Set: Initiation and Sustainment of Tokamak Plasmas with Local Helicity Injection as the Majority Current Drive

    DOE Data Explorer

    Perry, Justin M. [University of Wisconsin-Madison] (ORCID:0000000171228609); Bodner, Grant M. [University of Wisconsin-Madison] (ORCID:0000000324979172); Bongard, Michael W. [University of Wisconsin-Madison] (ORCID:0000000231609746); Burke, Marcus G. [University of Wisconsin-Madison] (ORCID:0000000176193724); Fonck, Raymond J. [University of Wisconsin-Madison] (ORCID:0000000294386762); Pachicano, Jessica L. [University of Wisconsin-Madison] (ORCID:0000000207255693); Pierren, Christopher [University of Wisconsin-Madison] (ORCID:0000000228289825); Reusch, Joshua A. [University of Wisconsin-Madison] (ORCID:0000000284249422); Rhodes, Alexander T. [University of Wisconsin-Madison] (ORCID:0000000280735714); Richner, Nathan J. [University of Wisconsin-Madison] (ORCID:0000000155443915); Rodriguez Sanchez, Cuauhtemoc [University of Wisconsin-Madison] (ORCID:0000000334712586); Schaefer, Carolyn E. [University of Wisconsin-Madison] (ORCID:0000000248848727); Weberski, Justin D. [University of Wisconsin-Madison] (ORCID:0000000256267914)

    2018-05-22

    This public data set contains openly-documented, machine readable digital research data corresponding to figures published in J.M. Perry et al., 'Initiation and Sustainment of Tokamak Plasmas with Local Helicity Injection as the Majority Current Drive,' accepted for publication in Nuclear Fusion.

  11. Electrical resistance tomography using steel cased boreholes as electrodes

    DOEpatents

    Daily, W.D.; Ramirez, A.L.

    1999-06-22

    An electrical resistance tomography method is described which uses steel cased boreholes as electrodes. The method enables mapping the electrical resistivity distribution in the subsurface from measurements of electrical potential caused by electrical currents injected into an array of electrodes in the subsurface. By use of current injection and potential measurement electrodes to generate data about the subsurface resistivity distribution, which data is then used in an inverse calculation, a model of the electrical resistivity distribution can be obtained. The inverse model may be constrained by independent data to better define an inverse solution. The method utilizes pairs of electrically conductive (steel) borehole casings as current injection electrodes and as potential measurement electrodes. The greater the number of steel cased boreholes in an array, the greater the amount of data is obtained. The steel cased boreholes may be utilized for either current injection or potential measurement electrodes. The subsurface model produced by this method can be 2 or 3 dimensional in resistivity depending on the detail desired in the calculated resistivity distribution and the amount of data to constrain the models. 2 figs.

  12. Electrical resistance tomography using steel cased boreholes as electrodes

    DOEpatents

    Daily, William D.; Ramirez, Abelardo L.

    1999-01-01

    An electrical resistance tomography method using steel cased boreholes as electrodes. The method enables mapping the electrical resistivity distribution in the subsurface from measurements of electrical potential caused by electrical currents injected into an array of electrodes in the subsurface. By use of current injection and potential measurement electrodes to generate data about the subsurface resistivity distribution, which data is then used in an inverse calculation, a model of the electrical resistivity distribution can be obtained. The inverse model may be constrained by independent data to better define an inverse solution. The method utilizes pairs of electrically conductive (steel) borehole casings as current injection electrodes and as potential measurement electrodes. The greater the number of steel cased boreholes in an array, the greater the amount of data is obtained. The steel cased boreholes may be utilized for either current injection or potential measurement electrodes. The subsurface model produced by this method can be 2 or 3 dimensional in resistivity depending on the detail desired in the calculated resistivity distribution and the amount of data to constain the models.

  13. Drain current enhancement induced by hole injection from gate of 600-V-class normally off gate injection transistor under high temperature conditions up to 200 °C

    NASA Astrophysics Data System (ADS)

    Ishii, Hajime; Ueno, Hiroaki; Ueda, Tetsuzo; Endoh, Tetsuo

    2018-06-01

    In this paper, the current–voltage (I–V) characteristics of a 600-V-class normally off GaN gate injection transistor (GIT) from 25 to 200 °C are analyzed, and it is revealed that the drain current of the GIT increases during high-temperature operation. It is found that the maximum drain current (I dmax) of the GIT is 86% higher than that of a conventional 600-V-class normally off GaN metal insulator semiconductor hetero-FET (MIS-HFET) at 150 °C, whereas the GIT obtains 56% I dmax even at 200 °C. Moreover, the mechanism of the drain current increase of the GIT is clarified by examining the relationship between the temperature dependence of the I–V characteristics of the GIT and the gate hole injection effect determined from the shift of the second transconductance (g m) peak of the g m–V g characteristic. From the above, the GIT is a promising device with enough drivability for future power switching applications even under high-temperature conditions.

  14. Expanding Non-solenoidal Startup with Local Helicity Injection to Increased Toroidal Field and Helicity Injection Rate

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Barr, J. L.; Bodner, G. M.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Reusch, J. A.; Schlossberg, D. J.; Winz, G. R.

    2015-11-01

    Local helicity injection (LHI) is a non-solenoidal startup technique under development on the Pegasus ST. Plasma currents up to 0.18 MA have been initiated by LHI in conjunction with poloidal field induction. A 0-D power balance model has been developed to predict plasma current evolution by balancing helicity input against resistive dissipation. The model is being validated against a set of experimental measurements and magnetic reconstructions with radically varied plasma geometric evolutions. Outstanding physics issues with LHI startup are the scalings of confinement and MHD activity with helicity injection rate and toroidal field strength, as well as injector behavior at high field. Preliminary results from the newly-installed Thomson scattering system suggest core temperatures of a few hundred eV during LHI startup. Measurements are being expanded to multiple spatial points for ongoing confinement studies. A set of larger-area injectors is being installed in the lower divertor region, where increased toroidal field will provide a helicity injection rate over 3 times that of outboard injectors. In this regime helicity injection will be the dominant current drive. Experiments with divertor injectors will permit experimental differentiation of several possible confinement models, and demonstrate the feasibility of LHI startup at high field. Work supported by US DOE grant DE-FG02-96ER54375.

  15. The Use of Milrinone in Patients with Delayed Cerebral Ischemia Following Subarachnoid Hemorrhage: A Systematic Review.

    PubMed

    Lannes, Marcelo; Zeiler, Frederick; Guichon, Céline; Teitelbaum, Jeanne

    2017-03-01

    The purpose of this article is to provide a systematic review of the evidence supporting the use of milrinone for the management of delayed cerebral ischemia (DCI) following subarachnoid hemorrhage (SAH). Primary outcomes were functional neurological status and the incidence of cerebral infarction. Search strategies adapted to the different databases were developed by a professional librarian. Medline, EMBASE, the Cochrane Library database, Web of Science, SCOPUS, BIOSIS, Global Health, Health Star, Open SIGLE, Google Scholar and the New York Academy of Medicine Gray Literature were searched as well as clinical trials databases and the proceedings of several scientific meetings. Quality of the evidence for these outcomes across studies was adjudicated using the GRADE Working Group criteria. The search resulted in 284 citations after elimination of duplicates. Of those 9 conference proceedings and 15 studies met inclusion criteria and consisted of case reports, case series and two comparative studies: one non-randomized study with physiological outcomes only and a case series with historical controls. There was considerable variation in dosing and in co-interventions and no case control or randomized controlled studies were found. There is currently only very low quality evidence to support the use of milrinone to improve important outcomes in patients with delayed cerebral ischemia secondary to subarachnoid hemorrhage. Further research is needed to clarify the value and risks of this medication in patients with SAH.

  16. Bulk Current Injection Testing of Cable Noise Reduction Techniques, 50 kHz to 400 MHz

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Hare, Richard J.; Singh, Manisha

    2009-01-01

    This paper presents empirical results of cable noise reduction techniques as demonstrated using bulk current injection (BCI) techniques with radiated fields from 50 kHz - 400 MHz. It is a follow up to the two-part paper series presented at the Asia Pacific EMC Conference that focused on TEM cell signal injection. This paper discusses the effects of cable types, shield connections, and chassis connections on cable noise. For each topic, well established theories are compared with data from a real-world physical system.

  17. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

    PubMed

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-07-07

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10-400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215-25) with Tikhonov regularization and the harmonic B(Z) proposed by Oh et al (2003 Magn. Reason. Med. 50 875-8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total acquisition time for 200 µA and 5 mA experiments was about 1 h and 8.5 min, respectively. The results demonstrate that conductivity imaging is possible at low currents using the suggested imaging parameters and reconstructing the images using iterative SMM with Tikhonov regularization, which appears to be more tolerant to noisy data than harmonic B(Z).

  18. Dependence of electron peak current on hollow cathode dimensions and seed electron energy in a pseudospark discharge

    NASA Astrophysics Data System (ADS)

    Cetiner, S. O.; Stoltz, P.; Messmer, P.; Cambier, J.-L.

    2008-01-01

    The prebreakdown and breakdown phases of a pseudospark discharge are investigated using the two-dimensional kinetic plasma simulation code OOPIC™ PRO. Trends in the peak electron current at the anode are presented as function of the hollow cathode dimensions and mean seed injection velocities at the cavity back wall. The plasma generation process by ionizing collisions is examined, showing the effect on supplying the electrons that determine the density of the beam. The mean seed velocities used here are varied between the velocity corresponding to the energy of peak ionization cross section, 15 times this value and no mean velocity (i.e., electrons injected with a temperature of 2.5eV). The reliance of the discharge characteristics on the penetrating electric field is shown to decrease as the mean seed injection velocity increases because of its ability to generate a surplus plasma independent of the virtual anode. As a result, the peak current increases with the hollow cathode dimensions for the largest average injection velocity, while for the smallest value it increases with the area of penetration of the electric field in the hollow cathode interior. Additionally, for a given geometry an increase in the peak current with the surplus plasma generated is observed. For the largest seed injection velocity used a dependence of the magnitude of the peak current on the ratio of the hole thickness and hollow cathode depth to the hole height is demonstrated. This means similar trends of the peak current are generated when the geometry is resized. Although the present study uses argon only, the variation in the discharge dependencies with the seed injection energy relative to the ionization threshold is expected to apply independently of the gas type. Secondary electrons due to electron and ion impact are shown to be important only for the largest impact areas and discharge development times of the study.

  19. Measuring resistivity changes from within a first cased well to monitor fluids injected into oil bearing geological formations from a second cased well while passing electrical current between the two cased wells

    DOEpatents

    Vail, III, William B.

    1993-01-01

    A.C. current is conducted through geological formations separating two cased wells in an oil field undergoing enhanced oil recovery operations such as water flooding operations. Methods and apparatus are disclosed to measure the current leakage conducted into a geological formation from within a first cased well that is responsive to fluids injected into formation from a second cased well during the enhanced oil production activities. The current leakage and apparent resistivity measured within the first cased well are responsive to fluids injected into formation from the second cased well provided the distance of separation between the two cased wells is less than, or on the order of, a Characteristic Length appropriate for the problem.

  20. Measuring resistivity changes from within a first cased well to monitor fluids injected into oil bearing geological formations from a second cased well while passing electrical current between the two cased wells

    DOEpatents

    Vail, W.B. III.

    1993-02-16

    A.C. current is conducted through geological formations separating two cased wells in an oil field undergoing enhanced oil recovery operations such as water flooding operations. Methods and apparatus are disclosed to measure the current leakage conducted into a geological formation from within a first cased well that is responsive to fluids injected into formation from a second cased well during the enhanced oil production activities. The current leakage and apparent resistivity measured within the first cased well are responsive to fluids injected into formation from the second cased well provided the distance of separation between the two cased wells is less than, or on the order of, a Characteristic Length appropriate for the problem.

  1. Currents Induced by Injected Charge in Junction Detectors

    PubMed Central

    Gaubas, Eugenijus; Ceponis, Tomas; Kalesinskas, Vidas

    2013-01-01

    The problem of drifting charge-induced currents is considered in order to predict the pulsed operational characteristics in photo- and particle-detectors with a junction controlled active area. The direct analysis of the field changes induced by drifting charge in the abrupt junction devices with a plane-parallel geometry of finite area electrodes is presented. The problem is solved using the one-dimensional approach. The models of the formation of the induced pulsed currents have been analyzed for the regimes of partial and full depletion. The obtained solutions for the current density contain expressions of a velocity field dependence on the applied voltage, location of the injected surface charge domain and carrier capture parameters. The drift component of this current coincides with Ramo's expression. It has been illustrated, that the synchronous action of carrier drift, trapping, generation and diffusion can lead to a vast variety of possible current pulse waveforms. Experimental illustrations of the current pulse variations determined by either the rather small or large carrier density within the photo-injected charge domain are presented, based on a study of Si detectors. PMID:24036586

  2. Potential geographic "hotspots" for drug-injection related transmission of HIV and HCV and for initiation into injecting drug use in New York City, 2011-2015, with implications for the current opioid epidemic in the US

    PubMed Central

    Cooper, H. L. F.; Arasteh, K.; Feelemyer, J.; McKnight, C.; Ross, Z.

    2018-01-01

    Objective We identified potential geographic “hotspots” for drug-injecting transmission of HIV and hepatitis C virus (HCV) among persons who inject drugs (PWID) in New York City. The HIV epidemic among PWID is currently in an “end of the epidemic” stage, while HCV is in a continuing, high prevalence (> 50%) stage. Methods We recruited 910 PWID entering Mount Sinai Beth Israel substance use treatment programs from 2011–2015. Structured interviews and HIV/ HCV testing were conducted. Residential ZIP codes were used as geographic units of analysis. Potential “hotspots” for HIV and HCV transmission were defined as 1) having relatively large numbers of PWID 2) having 2 or more HIV (or HCV) seropositive PWID reporting transmission risk—passing on used syringes to others, and 3) having 2 or more HIV (or HCV) seronegative PWID reporting acquisition risk—injecting with previously used needles/syringes. Hotspots for injecting drug use initiation were defined as ZIP codes with 5 or more persons who began injecting within the previous 6 years. Results Among PWID, 96% injected heroin, 81% male, 34% White, 15% African-American, 47% Latinx, mean age 40 (SD = 10), 7% HIV seropositive, 62% HCV seropositive. Participants resided in 234 ZIP codes. No ZIP codes were identified as potential hotspots due to small numbers of HIV seropositive PWID reporting transmission risk. Four ZIP codes were identified as potential hotspots for HCV transmission. 12 ZIP codes identified as hotspots for injecting drug use initiation. Discussion For HIV, the lack of potential hotspots is further validation of widespread effectiveness of efforts to reduce injecting-related HIV transmission. Injecting-related HIV transmission is likely to be a rare, random event. HCV prevention efforts should include focus on potential hotspots for transmission and on hotspots for initiation into injecting drug use. We consider application of methods for the current opioid epidemic in the US. PMID:29596464

  3. Connecting polar research to NGSS STEM classroom lessons

    NASA Astrophysics Data System (ADS)

    Brinker, R.; Kast, D.

    2016-12-01

    Next Generation Science Standards (NGSS) are designed to bring consistent, rigorous science teaching across the United States. Topics are categorized as Performance Expectations (PE), Disciplinary Core Ideas (DCI), Cross-Cutting Concepts (CCC), and Science and Engineering Practices (SEP). NGSS includes a focus on environmental science and climate change across grade levels. Earth and planetary sciences are required at the high school level. Integrating polar science lessons into NGSS classrooms brings relevant, rigorous climate change curriculum across grade levels. Polar science provides opportunities for students to use current data during lessons, conduct their own field work, and collaborate with scientists. Polar science provides a framework of learning that is novel to most students. Inquiry and engagement are high with polar science lessons. Phenomenon related to polar science provide an excellent tool for science teachers to use to engage students in a lesson, stimulate inquiry, and promote critical thinking. When taught effectively, students see the connections between their community, polar regions and climate change, regardless of where on the planet students live. This presentation describes examples of how to effectively implement NGSS lessons by incorporating polar science lessons and field research. Examples of introductory phenomenon and aligned PEs, CCCs, DCIs, and SEPs are given. Suggested student activities, assessments, examples of student work, student research, labs, and PolarTREC fieldwork, use of current science data, and connections to scientists in the field are provided. The goals of the presentation are to give teachers a blueprint to follow when implementing NGSS lessons, and give scientists an understanding of the basics of NGSS so they may be better able to relate their work to U.S. science education and be more effective communicators of their science findings.

  4. Enhancement of minority carrier injection in ambipolar carbon nanotube transistors using double-gate structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Bongjun; Liang, Kelly; Dodabalapur, Ananth, E-mail: ananth.dodabalapur@engr.utexas.edu

    We show that double-gate ambipolar thin-film transistors can be operated to enhance minority carrier injection. The two gate potentials need to be significantly different for enhanced injection to be observed. This enhancement is highly beneficial in devices such as light-emitting transistors where balanced electron and hole injections lead to optimal performance. With ambipolar single-walled carbon nanotube semiconductors, we demonstrate that higher ambipolar currents are attained at lower source-drain voltages, which is desired for portable electronic applications, by employing double-gate structures. In addition, when the two gates are held at the same potential, the expected advantages of the double-gate transistors suchmore » as enhanced on-current are also observed.« less

  5. Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

    PubMed

    Nayak, Rabindra S; Shafiuddin, Bareera; Pasha, Azam; Vinay, K; Narayan, Anjali; Shetty, Smitha V

    2015-07-01

    Technological advances in wire selection and bracket design have led to improved treatment efficiency and allowed longer time intervals between appliance adjustments. The wires remain in the mouth for a longer duration and are subjected to electrochemical reactions, mechanical forces of mastication and generalized wear. These cause different types of corrosion. This study was done to compare the galvanic currents generated between different combinations of brackets and archwires commonly used in orthodontic practices. The materials used for the study included different commercially available orthodontic archwires and brackets. The galvanic current generated by individual materials and different combinations of these materials was tested and compared. The orthodontic archwires used were 0.019″ × 0.025″ heat-activated nickel-titanium (3M Unitek), 0.019″ × 0.025″ beta-titanium (3M Unitek) and 0.019″ × 0.025″ stainless steel (3M Unitek). The orthodontic brackets used were 0.022″ MBT laser-cut (Victory Series, 3M Unitek) and metal-injection molded (Leone Company) maxillary central incisor brackets respectively. The ligature wire used for ligation was 0.009″ stainless steel ligature (HP Company). The galvanic current for individual archwires, brackets, and the different bracket-archwire-ligature combinations was measured by using a Potentiostat machine. The data were generated using the Linear Sweep Voltammetry and OriginPro 8.5 Graphing and Data Analysis Softwares. The study was conducted in two phases. Phase I comprised of five groups for open circuit potential (OCP) and galvanic current (I), whereas Phase II comprised of six groups for galvanic current alone. Mean, standard deviation and range were computed for the OCP and galvanic current (I) values obtained. Results were subjected to statistical analysis through ANOVA. In Phase I, higher mean OCP was recorded in stainless steel archwire, followed by beta-titanium archwire, heat-activated nickel titanium archwire, laser-cut bracket and metal-injection molded bracket, respectively. The difference in mean OCP recorded among the groups was found to be statistically significant in aerated phosphate buffered saline solution. The galvanic current (I) for metal-injection molded stainless steel brackets showed significantly higher values than all the other materials. Phase II results suggested that, in the couples formed by the archwire-bracket-ligature combinations, the bracket had more important contribution to the total galvanic current generated, since there were significant differences between galvanic current among the 2 brackets tested but not among the 3 wires. The galvanic current of the metal-injection molded bracket was significantly higher than that of laser-cut bracket. Highest mean current (I) was recorded in metal-injection molded bracket when used with heat-activated nickel titanium archwire while lowest mean current (I) was recorded in laser-cut bracket when used with beta-titanium archwire. The present study concluded that the bracket emerged to be the most important factor in determining the galvanic current (I). Higher mean current (I) was recorded in metal-injection molded bracket compared to laser-cut bracket. Among the three archwires, higher mean current (I) was recorded in heat-activated nickel-titanium, followed by stainless-steel and beta-titanium respectively. When coupled together; highest mean current (I) was recorded in metal-injection molded bracket when used with heat-activated nickel titanium archwire while lowest mean current (I) was recorded in laser-cut bracket when used with beta-titanium archwire.

  6. Plasma response to sustainment with imposed-dynamo current drive in HIT-SI and HIT-SI3

    NASA Astrophysics Data System (ADS)

    Hossack, A. C.; Jarboe, T. R.; Chandra, R. N.; Morgan, K. D.; Sutherland, D. A.; Penna, J. M.; Everson, C. J.; Nelson, B. A.

    2017-07-01

    The helicity injected torus—steady inductive (HIT-SI) program studies efficient, steady-state current drive for magnetic confinement plasmas using a novel experimental method. Stable, high-beta spheromaks have been sustained using steady, inductive current drive. Externally induced loop voltage and magnetic flux are oscillated together so that helicity and power injection are always positive, sustaining the edge plasma current indefinitely. Imposed-dynamo current drive (IDCD) theory further shows that the entire plasma current is sustained. The method is ideal for low aspect ratio, toroidal geometries with closed flux surfaces. Experimental studies of spheromak plasmas sustained with IDCD have shown stable magnetic profiles with evidence of pressure confinement. New measurements show coherent motion of a stable spheromak in response to the imposed perturbations. On the original device two helicity injectors were mounted on either side of the spheromak and the injected mode spectrum was predominantly n  =  1. Coherent, rigid motion indicates that the spheromak is stable and a lack of plasma-generated n  =  1 energy indicates that the maximum q is maintained below 1 during sustainment. Results from the HIT-SI3 device are also presented. Three inductive helicity injectors are mounted on one side of the spheromak flux conserver. Varying the relative injector phasing changes the injected mode spectrum which includes n  =  2, 3, and higher modes.

  7. Dislocation related droop in InGaN/GaN light emitting diodes investigated via cathodoluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pozina, Galia; Ciechonski, Rafal; Bi, Zhaoxia

    2015-12-21

    Today's energy saving solutions for general illumination rely on efficient white light emitting diodes (LEDs). However, the output efficiency droop experienced in InGaN based LEDs with increasing current injection is a serious limitation factor for future development of bright white LEDs. We show using cathodoluminescence (CL) spatial mapping at different electron beam currents that threading dislocations are active as nonradiative recombination centers only at high injection conditions. At low current, the dislocations are inactive in carrier recombination due to local potentials, but these potentials are screened by carriers at higher injection levels. In CL images, this corresponds to the increasemore » of the dark contrast around dislocations with the injection (excitation) density and can be linked with droop related to the threading dislocations. Our data indicate that reduction of droop in the future efficient white LED can be achieved via a drastic reduction of the dislocation density by using, for example, bulk native substrates.« less

  8. New injectors and the social context of injection initiation

    PubMed Central

    Harocopos, Alex; Goldsamt, Lloyd A.; Kobrak, Paul; Jost, John J.; Clatts, Michael C.

    2009-01-01

    Background Preventing the onset of injecting drug use is an important public health objective yet there is little understanding of the process that leads to injection initiation. This paper draws extensively on narrative data to describe how injection initiation is influenced by social environment. We examine how watching other people inject can habitualise non-injectors to administering drugs with a needle and consider the process by which the stigma of injecting is replaced with curiosity. Method In-depth interviews (n=54) were conducted as part of a two-year longitudinal study examining the behaviours of new injecting drug users. Results Among our sample, injection initiation was the result of a dynamic process during which administering drugs with a needle became acceptable or even appealing. Most often, this occurred as a result of spending time with current injectors in a social context and the majority of this study’s participants were given their first shot by a friend or sexual partner. Initiates could be tenacious in their efforts to acquire an injection trainer and findings suggest that once injecting had been introduced to a drug-using network, it was likely to spread throughout the group. Conclusion Injection initiation should be viewed as a communicable process. New injectors are unlikely to have experienced the negative effects of injecting and may facilitate the initiation of their drug-using friends. Prevention messages should therefore aim to find innovative ways of targeting beginning injectors and present a realistic appraisal of the long-term consequences of injecting. Interventionists should also work with current injectors to develop strategies to refuse requests from non-injectors for their help to initiate. PMID:18790623

  9. Progress of long pulse operation with high performance plasma in KSTAR

    NASA Astrophysics Data System (ADS)

    Bae, Young; Kstar Team

    2015-11-01

    Recent KSTAR experiments showed the sustained H-mode operation up to the pulse duration of 46 s at the plasma current of 600 kA. The long-pulse H-mode operation has been supported by long-pulse capable neutral beam injection (NBI) system with high NB current drive efficiency attributed by highly tangential injections of three beam sources. In next phase, aiming to demonstrate the long pulse stationary high performance plasma operation, we are attempting the long pulse inductive operation at the higher performance (MA plasma current, high normalized beta, and low q95) for the final goal of demonstration of ITER-like baseline scenario in KSTAR with progressive improvement of the plasma shape control and higher neutral beam injection power. This paper presents the progress of long pulse operation and the analysis of energy confinement time and non-inductive current drive in KSTAR.

  10. Optical gain in colloidal quantum dots achieved with direct-current electrical pumping

    NASA Astrophysics Data System (ADS)

    Lim, Jaehoon; Park, Young-Shin; Klimov, Victor I.

    2018-01-01

    Chemically synthesized semiconductor quantum dots (QDs) can potentially enable solution-processable laser diodes with a wide range of operational wavelengths, yet demonstrations of lasing from the QDs are still at the laboratory stage. An important challenge--realization of lasing with electrical injection--remains unresolved, largely due to fast nonradiative Auger recombination of multicarrier states that represent gain-active species in the QDs. Here we present population inversion and optical gain in colloidal nanocrystals realized with direct-current electrical pumping. Using continuously graded QDs, we achieve a considerable suppression of Auger decay such that it can be outpaced by electrical injection. Further, we apply a special current-focusing device architecture, which allows us to produce high current densities (j) up to ~18 A cm-2 without damaging either the QDs or the injection layers. The quantitative analysis of electroluminescence and current-modulated transmission spectra indicates that with j = 3-4 A cm-2 we achieve the population inversion of the band-edge states.

  11. Controlling heat and particle currents in nanodevices by quantum observation

    NASA Astrophysics Data System (ADS)

    Biele, Robert; Rodríguez-Rosario, César A.; Frauenheim, Thomas; Rubio, Angel

    2017-07-01

    We demonstrate that in a standard thermo-electric nanodevice the current and heat flows are not only dictated by the temperature and potential gradient, but also by the external action of a local quantum observer that controls the coherence of the device. Depending on how and where the observation takes place, the direction of heat and particle currents can be independently controlled. In fact, we show that the current and heat flow in a quantum material can go against the natural temperature and voltage gradients. Dynamical quantum observation offers new possibilities for the control of quantum transport far beyond classical thermal reservoirs. Through the concept of local projections, we illustrate how we can create and directionality control the injection of currents (electronic and heat) in nanodevices. This scheme provides novel strategies to construct quantum devices with application in thermoelectrics, spintronic injection, phononics, and sensing among others. In particular, highly efficient and selective spin injection might be achieved by local spin projection techniques.

  12. Incarceration and injection drug use in Baltimore, Maryland.

    PubMed

    Genberg, Becky L; Astemborski, Jacquie; Vlahov, David; Kirk, Gregory D; Mehta, Shruti H

    2015-07-01

    There is limited longitudinal research examining incarceration and subsequent changes in drug use among people who inject drugs (PWID) in the United States. The objective of the current study was to characterize the frequency of incarceration and estimate the association between incarceration and subsequent injection drug use among current and former PWIDs in one US city. ALIVE (AIDS Linked to the Intravenous Experience) is a prospective cohort study of current and former PWIDs, with semi-annual follow-up occurring since 1988. Baltimore, Maryland, USA. A total of 3245 participants with 48 738 study visits were included. Participants enrolled from 1988 to 2012 with a median of 13 follow-up visits per participant (Interquartile range = 7-25). Incarcerations were defined as any self-reported jail or prison stays in the previous 6 months that were ≥7 days or longer. The primary outcome was defined as any self-reported injection drug use in the previous 6 months. At baseline, 29% were female, 90% African American and 33% HIV-positive. Fifty-seven per cent of participants experienced at least one incarceration episode. After adjusting for confounders, there was a positive association between incarceration and subsequent injection drug use [adjusted odds ratio (AOR) = 1.48, 95% confidence interval (CI) = 1.37-1.59]; however, stratified analysis showed that the effect was restricted to those who were not injecting at the time of incarceration (AOR = 2.11, 95% CI = 1.88-2.37). In the United States, incarceration of people who had previously stopped injecting drugs appears to be associated with an increased risk of subsequent injecting. © 2015 Society for the Study of Addiction.

  13. PDCI Wide-Area Damping Control: PSLF Simulations of the 2016 Open and Closed Loop Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilches Bernal, Felipe; Pierre, Brian Joseph; Elliott, Ryan Thomas

    To demonstrate and validate the performance of the wide-are a damping control system, the project plans to conduct closed-loop tests on the PDCI in summer/fall 2016. A test plan details the open and closed loop tests to be conducted on the P DCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the result s from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations usemore » the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases.« less

  14. Proceedings of Colloquium/Workshop on Composite Materials and Structures, Standardization, Qualification, Certification Held at Washington, DC on 8-10 May 1984.

    DTIC Science & Technology

    1984-07-01

    CHANNON JUL 84 IDA-D-7e EhhhChEIE’hSED hhhE-84C-hhIE/G11/hI A~ 4 - &1220 MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU Of STANDARDS-1963-A cm" 154dM...IDALg N.NO W0.2 W8 . . . .. . . . .’% >. .’. 2. *~~~~~~7 F. V.* * 4 .-& - * ** The wrk rupsed hIts d.... de wuo uumiucd maig Peurt b MM 06384 C 0631...I REP REPORT DOCUMENTATION PAGE E DCY SOJ I. REPOR mussee A4rEV~ION NO. PMRS4 EN TI CATALO0 GE , 4 T~IT iW# sbftt Clcui bkhP Or REPORT a PERIOD

  15. Magnetic Helicity Injection and Thermal Transport

    NASA Astrophysics Data System (ADS)

    Moses, Ronald; Gerwin, Richard; Schoenberg, Kurt

    1999-11-01

    In magnetic helicity injection, a current is driven between electrodes, parallel to the magnetic field in the edge plasma of a machine.^1 Plasma instabilities distribute current throughout the plasma. To model the injection of magnetic helicity, K, into an arbitrary closed surface, K is defined as the volume integral of A^.B. To make K unique, a gauge is chosen where the tangential surface components of A are purely solenoidal. If magnetic fields within a plasma are time varying, yet undergo no macroscopic changes over an extended period, and if the plasma is subject to an Ohm’s law with Hall terms, then it is shown that no closed magnetic surfaces with sustained internal currents can exist continuously within the plasma.^2 It is also shown that parallel thermal transport connects all parts of the plasma to the helicity injection electrodes and requires the electrode voltage difference to be at least 2.5 to 3 times the peak plasma temperature. This ratio is almost independent of the length of the electron mean-free path. If magnetic helicity injection is to be used for fusion-grade plasmas, then high-voltage, high-impedance injection techniques must be developed. ^1T. R. Jarboe, Plasma Physics and Controlled Fusion, V36, 945-990 (June 1994). ^2R. W. Moses, 1991 Sherwood International Fusion Theory Conference, Seattle, WA (April 22-24, 1991).

  16. Electrochemical attosyringe.

    PubMed

    Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V

    2007-07-17

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.

  17. Electrochemical attosyringe

    PubMed Central

    Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.

    2007-01-01

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612

  18. Injectable Hydrogels for Cardiac Tissue Repair after Myocardial Infarction

    PubMed Central

    Khattab, Ahmad; Islam, Mohammad Ariful; Hweij, Khaled Abou; Zeitouny, Joya; Waters, Renae; Sayegh, Malek; Hossain, Md Monowar; Paul, Arghya

    2015-01-01

    Cardiac tissue damage due to myocardial infarction (MI) is one of the leading causes of mortality worldwide. The available treatments of MI include pharmaceutical therapy, medical device implants, and organ transplants, all of which have severe limitations including high invasiveness, scarcity of donor organs, thrombosis or stenosis of devices, immune rejection, and prolonged hospitalization time. Injectable hydrogels have emerged as a promising solution for in situ cardiac tissue repair in infarcted hearts after MI. In this review, an overview of various natural and synthetic hydrogels for potential application as injectable hydrogels in cardiac tissue repair and regeneration is presented. The review starts with brief discussions about the pathology of MI, its current clinical treatments and their limitations, and the emergence of injectable hydrogels as a potential solution for post MI cardiac regeneration. It then summarizes various hydrogels, their compositions, structures and properties for potential application in post MI cardiac repair, and recent advancements in the application of injectable hydrogels in treatment of MI. Finally, the current challenges associated with the clinical application of injectable hydrogels to MI and their potential solutions are discussed to help guide the future research on injectable hydrogels for translational therapeutic applications in regeneration of cardiac tissue after MI. PMID:27668147

  19. An investigation of improved airbag performance by vent control and gas injection

    NASA Astrophysics Data System (ADS)

    Lee, Calvin; Rosato, Nick; Lai, Francis

    Airbags are currently being investigated as an impact energy absorber for U.S. Army airdrop. Simple airbags with constant vent areas have been found to be unsatisfactory in yielding high G forces. In this paper, a method of controlling the vent area and a method of injecting gas into the airbag during its compression stroke to improve airbag performance are presented. Theoretical analysis of complex airbags using these two methods show that they provide lower G forces than simple airbags. Vertical drop tests of a vent-control airbag confirm this result. Gas-injection airbags are currently being tested.

  20. Contact-metal dependent current injection in pentacene thin-film transistors

    NASA Astrophysics Data System (ADS)

    Wang, S. D.; Minari, T.; Miyadera, T.; Tsukagoshi, K.; Aoyagi, Y.

    2007-11-01

    Contact-metal dependent current injection in top-contact pentacene thin-film transistors is analyzed, and the local mobility in the contact region was found to follow the Meyer-Neldel rule. An exponential trap distribution, rather than the metal/organic hole injection barrier, is proposed to be the dominant factor of the contact resistance in pentacene thin-film transistors. The variable temperature measurements revealed a much narrower trap distribution in the copper contact compared with the corresponding gold contact, and this is the origin of the smaller contact resistance for copper despite a lower work function.

  1. NIMROD simulations and physics assessment of possible designs for a next generation Steady Inductive Helicity Injection HIT device

    NASA Astrophysics Data System (ADS)

    Penna, James; Morgan, Kyle; Grubb, Isaac; Jarboe, Thomas

    2017-10-01

    The Helicity Injected Torus - Steady Inductive 3 (HIT-SI3) experiment forms and maintains spheromaks via Steady Inductive Helicity Injection (SIHI) using discrete injectors that inject magnetic helicity via a non-axisymmetric perturbation and drive toroidally symmetric current. Newer designs for larger SIHI-driven spheromaks incorporate a set of injectors connected to a single external manifold to allow more freedom for the toroidal structure of the applied perturbation. Simulations have been carried out using the NIMROD code to assess the effectiveness of various imposed mode structures and injector schema in driving current via Imposed Dynamo Current Drive (IDCD). The results are presented here for varying flux conserver shapes on a device approximately 1.5 times larger than the current HIT-SI3 experiment. The imposed mode structures and spectra of simulated spheromaks are analyzed in order to examine magnetic structure and stability and determine an optimal regime for IDCD sustainment in a large device. The development of scaling laws for manifold operation is also presented, and simulation results are analyzed and assessed as part of the development path for the large scale device.

  2. Current profile redistribution driven by neutral beam injection in a reversed-field pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parke, E.; Department of Physics, University of Wisconsin-Madison 1150 University Ave., Madison, Wisconsin 53706; Anderson, J. K.

    2016-05-15

    Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm withmore » neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q{sub 0} by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].« less

  3. Spin-transfer torque induced spin waves in antiferromagnetic insulators

    DOE PAGES

    Daniels, Matthew W.; Guo, Wei; Stocks, George Malcolm; ...

    2015-01-01

    We explore the possibility of exciting spin waves in insulating antiferromagnetic films by injecting spin current at the surface. We analyze both magnetically compensated and uncompensated interfaces. We find that the spin current induced spin-transfer torque can excite spin waves in insulating antiferromagnetic materials and that the chirality of the excited spin wave is determined by the polarization of the injected spin current. Furthermore, the presence of magnetic surface anisotropy can greatly increase the accessibility of these excitations.

  4. Disruption mitigation by injection of small quantities of noble gas in ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Pautasso, G.; Bernert, M.; Dibon, M.; Duval, B.; Dux, R.; Fable, E.; Fuchs, J. C.; Conway, G. D.; Giannone, L.; Gude, A.; Herrmann, A.; Hoelzl, M.; McCarthy, P. J.; Mlynek, A.; Maraschek, M.; Nardon, E.; Papp, G.; Potzel, S.; Rapson, C.; Sieglin, B.; Suttrop, W.; Treutterer, W.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2017-01-01

    The most recent experiments of disruption mitigation by massive gas injection in ASDEX Upgrade have concentrated on small—relatively to the past—quantities of noble gas injected, and on the search for the minimum amount of gas necessary for the mitigation of the thermal loads on the divertor and for a significant reduction of the vertical force during the current quench. A scenario for the generation of a long-lived runaway electron beam has been established; this allows the study of runaway current dissipation by moderate quantities of argon injected. This paper presents these recent results and discusses them in the more general context of physical models and extrapolation, and of the open questions, relevant for the realization of the ITER disruption mitigation system.

  5. Gas injected vacuum switch

    DOEpatents

    Hardin, K. Dan

    1977-01-01

    The disclosure relates to a gas injected vacuum switch comprising a housing having an interior chamber, a conduit for evacuating the interior chamber, within the chamber an anode and a cathode spaced from the anode, and a detonator for injecting electrically conductive gas into the chamber between the anode and the cathode to provide a current path therebetween.

  6. Thermally insensitive determination of the linewidth broadening factor in nanostructured semiconductor lasers using optical injection locking

    PubMed Central

    Wang, Cheng; Schires, Kevin; Osiński, Marek; Poole, Philip J.; Grillot, Frédéric

    2016-01-01

    In semiconductor lasers, current injection not only provides the optical gain, but also induces variation of the refractive index, as governed by the Kramers-Krönig relation. The linear coupling between the changes of the effective refractive index and the modal gain is described by the linewidth broadening factor, which is responsible for many static and dynamic features of semiconductor lasers. Intensive efforts have been made to characterize this factor in the past three decades. In this paper, we propose a simple, flexible technique for measuring the linewidth broadening factor of semiconductor lasers. It relies on the stable optical injection locking of semiconductor lasers, and the linewidth broadening factor is extracted from the residual side-modes, which are supported by the amplified spontaneous emission. This new technique has great advantages of insensitivity to thermal effects, the bias current, and the choice of injection-locked mode. In addition, it does not require the explicit knowledge of optical injection conditions, including the injection strength and the frequency detuning. The standard deviation of the measurements is less than 15%. PMID:27302301

  7. New diesel injection nozzle flow measuring device

    NASA Astrophysics Data System (ADS)

    Marčič, Milan

    2000-04-01

    A new measuring device has been developed for diesel injection nozzle testing, allowing measuring of the steady flow through injection nozzle and the injection rate. It can be best applied for measuring the low and high injection rates of the pintle and single hole nozzle. In steady flow measuring the fuel pressure at the inlet of the injection nozzle is 400 bar. The sensor of the measuring device measures the fuel charge, resulting from fuel rubbing in the fuel injection system, as well as from the temperature gradient in the sensor electrode. The electric charge is led to the charge amplifier, where it is converted into electric current and amplified. The amplifier can be used also to measure the mean injection rate value.

  8. How do drug market changes affect characteristics of injecting initiation and subsequent patterns of drug use? Findings from a cohort of regular heroin and methamphetamine injectors in Melbourne, Australia.

    PubMed

    Horyniak, Danielle; Stoové, Mark; Degenhardt, Louisa; Aitken, Campbell; Kerr, Thomas; Dietze, Paul

    2015-01-01

    Changes in drug market characteristics have been shown to affect drug use patterns but few studies have examined their impacts on injecting initiation experiences and subsequent patterns of injecting drug use (IDU). We collected data on self-reported injecting initiation experiences and past-month patterns of IDU from 688 regular heroin and methamphetamine injectors in Melbourne, Australia, who initiated injecting across three different drug market periods (prior to the Australian heroin shortage ('high heroin')/immediately following the shortage ('low heroin')/'contemporary' markets (fluctuating heroin and methamphetamine availability)). We used univariable and multivariable logistic regression to examine the relationship between period of injecting initiation and first drug injected, and multinomial logistic regression for the relationship between period of injecting initiation and current injecting patterns. 425 participants (62%) reported initiating injecting in the high heroin period, 146 (21%) in the low heroin period, and 117 (17%) in the contemporary period. Participants who initiated injecting during the low heroin period were twice as likely to initiate injecting using a drug other than heroin (AOR: 1.94, 95% CI: 1.27-2.95). The most common patterns of drug use among study participants in the month preceding interview were polydrug use (44%) and primary heroin use (41%). Injecting initiation period was either non-significantly or weakly associated with current drug use pattern, which was more strongly associated with other socio-demographic and drug use characteristics, particularly self-reported drug of choice. The drug market period in which injecting initiation occurred influenced the first drug injected and influenced some aspects of subsequent drug use. In the context of highly dynamic drug markets in which polydrug use is common there is a need for broad harm reduction and drug treatment services which are flexible and responsive to changing patterns of drug use. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. SHIWA Services for Workflow Creation and Sharing in Hydrometeorolog

    NASA Astrophysics Data System (ADS)

    Terstyanszky, Gabor; Kiss, Tamas; Kacsuk, Peter; Sipos, Gergely

    2014-05-01

    Researchers want to run scientific experiments on Distributed Computing Infrastructures (DCI) to access large pools of resources and services. To run these experiments requires specific expertise that they may not have. Workflows can hide resources and services as a virtualisation layer providing a user interface that researchers can use. There are many scientific workflow systems but they are not interoperable. To learn a workflow system and create workflows may require significant efforts. Considering these efforts it is not reasonable to expect that researchers will learn new workflow systems if they want to run workflows developed in other workflow systems. To overcome it requires creating workflow interoperability solutions to allow workflow sharing. The FP7 'Sharing Interoperable Workflow for Large-Scale Scientific Simulation on Available DCIs' (SHIWA) project developed the Coarse-Grained Interoperability concept (CGI). It enables recycling and sharing workflows of different workflow systems and executing them on different DCIs. SHIWA developed the SHIWA Simulation Platform (SSP) to implement the CGI concept integrating three major components: the SHIWA Science Gateway, the workflow engines supported by the CGI concept and DCI resources where workflows are executed. The science gateway contains a portal, a submission service, a workflow repository and a proxy server to support the whole workflow life-cycle. The SHIWA Portal allows workflow creation, configuration, execution and monitoring through a Graphical User Interface using the WS-PGRADE workflow system as the host workflow system. The SHIWA Repository stores the formal description of workflows and workflow engines plus executables and data needed to execute them. It offers a wide-range of browse and search operations. To support non-native workflow execution the SHIWA Submission Service imports the workflow and workflow engine from the SHIWA Repository. This service either invokes locally or remotely pre-deployed workflow engines or submits workflow engines with the workflow to local or remote resources to execute workflows. The SHIWA Proxy Server manages certificates needed to execute the workflows on different DCIs. Currently SSP supports sharing of ASKALON, Galaxy, GWES, Kepler, LONI Pipeline, MOTEUR, Pegasus, P-GRADE, ProActive, Triana, Taverna and WS-PGRADE workflows. Further workflow systems can be added to the simulation platform as required by research communities. The FP7 'Building a European Research Community through Interoperable Workflows and Data' (ER-flow) project disseminates the achievements of the SHIWA project to build workflow user communities across Europe. ER-flow provides application supports to research communities within (Astrophysics, Computational Chemistry, Heliophysics and Life Sciences) and beyond (Hydrometeorology and Seismology) to develop, share and run workflows through the simulation platform. The simulation platform supports four usage scenarios: creating and publishing workflows in the repository, searching and selecting workflows in the repository, executing non-native workflows and creating and running meta-workflows. The presentation will outline the CGI concept, the SHIWA Simulation Platform, the ER-flow usage scenarios and how the Hydrometeorology research community runs simulations on SSP.

  10. On the wide-range bias dependence of transistor d.c. and small-signal current gain factors.

    NASA Technical Reports Server (NTRS)

    Schmidt, P.; Das, M. B.

    1972-01-01

    Critical reappraisal of the bias dependence of the dc and small-signal ac current gain factors of planar bipolar transistors over a wide range of currents. This is based on a straightforward consideration of the three basic components of the dc base current arising due to emitter-to-base injected minority carrier transport, base-to-emitter carrier injection, and emitter-base surface depletion layer recombination effects. Experimental results on representative n-p-n and p-n-p silicon devices are given which support most of the analytical findings.

  11. Lethal Injection for Execution: Chemical Asphyxiation?

    PubMed Central

    Zimmers, Teresa A; Sheldon, Jonathan; Lubarsky, David A; López-Muñoz, Francisco; Waterman, Linda; Weisman, Richard; Koniaris, Leonidas G

    2007-01-01

    Background Lethal injection for execution was conceived as a comparatively humane alternative to electrocution or cyanide gas. The current protocols are based on one improvised by a medical examiner and an anesthesiologist in Oklahoma and are practiced on an ad hoc basis at the discretion of prison personnel. Each drug used, the ultrashort-acting barbiturate thiopental, the neuromuscular blocker pancuronium bromide, and the electrolyte potassium chloride, was expected to be lethal alone, while the combination was intended to produce anesthesia then death due to respiratory and cardiac arrest. We sought to determine whether the current drug regimen results in death in the manner intended. Methods and Findings We analyzed data from two US states that release information on executions, North Carolina and California, as well as the published clinical, laboratory, and veterinary animal experience. Execution outcomes from North Carolina and California together with interspecies dosage scaling of thiopental effects suggest that in the current practice of lethal injection, thiopental might not be fatal and might be insufficient to induce surgical anesthesia for the duration of the execution. Furthermore, evidence from North Carolina, California, and Virginia indicates that potassium chloride in lethal injection does not reliably induce cardiac arrest. Conclusions We were able to analyze only a limited number of executions. However, our findings suggest that current lethal injection protocols may not reliably effect death through the mechanisms intended, indicating a failure of design and implementation. If thiopental and potassium chloride fail to cause anesthesia and cardiac arrest, potentially aware inmates could die through pancuronium-induced asphyxiation. Thus the conventional view of lethal injection leading to an invariably peaceful and painless death is questionable. PMID:17455994

  12. MHD and Reconnection Activity During Local Helicity Injection

    NASA Astrophysics Data System (ADS)

    Barr, J. L.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Reusch, J. A.; Richner, N. J.

    2016-10-01

    Scaling local helicity injection (LHI) to larger devices requires a validated, predictive model of its current drive mechanism. NIMROD simulations predict the injected helical current streams persist in the edge and periodically reconnect to form axisymmetric current rings that travel into the bulk plasma to grow Ip and poloidal flux. In simulation, these events result in discrete bursts of Alfvénic-frequency MHD activity and jumps in Ip of order ΔIp Iinj , in qualitative agreement with large n = 1 activity found in experiment. Fast imaging prior to tokamak formation supports the instability of, and apparent reconnection between, adjacent helical streams. The bursts exhibit toroidal amplitude asymmetries consistent with a kink structure singly line-tied to the injectors. Internal measurements localize this activity to the injector radial location. Pairwise correlations of poloidal Mirnov coil amplitude and phase match expectations of an edge-localized current stream carrying Iinj. Prior to tokamak formation, reconnection from both adjacent helical windings and co-injected current streams are shown to strongly heat impurity ions. After tokamak formation, strong anomalous ion heating in the plasma edge is attributed to continuous reconnection between colinear streams. The n = 1 bursts occur less frequently as Ip rises, likely caused by increased stream stability as Bv rises and qedge drops. This evidence supports the general NIMROD model of LHI, confirms the persistence and role of the edge current streams, and motivates experiments at higher Iinj and BT. Supported by US DOE Grants DE-FG02-96ER54375, DE-SC0006928.

  13. Determination of head conductivity frequency response in vivo with optimized EIT-EEG.

    PubMed

    Dabek, Juhani; Kalogianni, Konstantina; Rotgans, Edwin; van der Helm, Frans C T; Kwakkel, Gert; van Wegen, Erwin E H; Daffertshofer, Andreas; de Munck, Jan C

    2016-02-15

    Electroencephalography (EEG) benefits from accurate head models. Dipole source modelling errors can be reduced from over 1cm to a few millimetres by replacing generic head geometry and conductivity with tailored ones. When adequate head geometry is available, electrical impedance tomography (EIT) can be used to infer the conductivities of head tissues. In this study, the boundary element method (BEM) is applied with three-compartment (scalp, skull and brain) subject-specific head models. The optimal injection of small currents to the head with a modular EIT current injector, and voltage measurement by an EEG amplifier is first sought by simulations. The measurement with a 64-electrode EEG layout is studied with respect to three noise sources affecting EIT: background EEG, deviations from the fitting assumption of equal scalp and brain conductivities, and smooth model geometry deviations from the true head geometry. The noise source effects were investigated depending on the positioning of the injection and extraction electrode and the number of their combinations used sequentially. The deviation from equal scalp and brain conductivities produces rather deterministic errors in the three conductivities irrespective of the current injection locations. With a realistic measurement of around 2 min and around 8 distant distinct current injection pairs, the error from the other noise sources is reduced to around 10% or less in the skull conductivity. The analysis of subsequent real measurements, however, suggests that there could be subject-specific local thinnings in the skull, which could amplify the conductivity fitting errors. With proper analysis of multiplexed sinusoidal EIT current injections, the measurements on average yielded conductivities of 340 mS/m (scalp and brain) and 6.6 mS/m (skull) at 2 Hz. From 11 to 127 Hz, the conductivities increased by 1.6% (scalp and brain) and 6.7% (skull) on the average. The proper analysis was ensured by using recombination of the current injections into virtual ones, avoiding problems in location-specific skull morphology variations. The observed large intersubject variations support the need for in vivo measurement of skull conductivity, resulting in calibrated subject-specific head models. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Physics of Intense Electron Current Sources for Helicity Injection

    NASA Astrophysics Data System (ADS)

    Hinson, E. T.; Barr, J. L.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Lewicki, B. T.; Perry, J. M.; Redd, A. J.; Winz, G. R.

    2014-10-01

    DC helicity injection (HI) for non-solenoidal ST startup requires sources of current at the tokamak edge. Since the rate of HI scales with injection voltage, understanding of the physics setting injector impedance is necessary for a predictive model of the HI rate and subsequent growth of Ip. In Pegasus, arc plasma sources are used for current injection. They operate immersed in tokamak edge plasma, and are biased at ~1-2 kV with respect to the vessel to draw current densities J ~ 1 kA/cm2 from an arc plasma cathode. Prior to tokamak formation, impedance data manifests two regimes, one at low current (< 1 kA) with I ~V 3 / 2 , and a higher current mode where I ~V 1 / 2 holds. The impedance in the I ~V 3 / 2 regime is consistent with an electrostatic double layer. Current in the I ~V 1 / 2 regime is linear in arc gas fueling rate, suggesting a space-charge limit set by nedge. In the presence of tokamak plasmas, voltage oscillations of the order 100s of volts are measured during MHD relaxation activity. These fluctuations occur at the characteristic frequencies of the n = 1 and n = 0 MHD activity observed on magnetic probes, and are suggestive of dynamic activity found in LHI simulations in NIMROD. Advanced injector design techniques have allowed higher voltage operation. These include staged shielding to prevent external arcing, and shaped cathodes, which minimize the onset and material damage due to cathode spot formation. Work supported by US DOE Grant DE-FG02-96ER54375.

  15. Agonist- and subunit-dependent potentiation of glutamate receptors by a nootropic drug aniracetam.

    PubMed

    Tsuzuki, K; Takeuchi, T; Ozawa, S

    1992-11-01

    GluR1 and GluR2 cDNAs encoding non-NMDA subtypes of glutamate receptor were isolated from a rat brain cDNA library by Boulter et al. (Science, 249 (1990) 1033-1037). Functional receptors activated by kainate, alpha-amino-3-hydroxy-5-methyl-4-isoxazole propionate (AMPA) and glutamate were expressed in Xenopus oocytes injected with GluR1, GluR2 or a mixture of GluR1 and GluR2 RNAs. In GluR1-expressed oocytes, 1 mM aniracetam potentiated AMPA-induced currents by 99 +/- 10% (mean +/- S.E.M., n = 5) and glutamate-induced currents by 140 +/- 8% (n = 4), but little affected kainate-induced currents. Aniracetam was effective from a concentration of 0.1 mM, and it exhibited more conspicuous effects with the increase of the dose. In oocytes injected with GluR1 plus GluR2 RNAs, aniracetam more markedly potentiated current responses to AMPA and glutamate than those in oocytes injected with GluR1 RNA alone. For example, 1 mM aniracetam potentiated AMPA-induced currents by 396 +/- 76% (n = 4) and glutamate-induced currents by 970 +/- 65% (n = 5) in oocytes injected with 10% GluR1 and 90% GluR2 RNAs. In these oocytes, however, the potentiation of kainate-induced currents by 1 mM aniracetam was only 8 +/- 5% (n = 4). Thus, we conclude that the potentiation of the AMPA/kainate receptor by aniracetam depends on both species of agonists and subunit composition of the receptor.

  16. Directional connectivity in hydrology and ecology.

    PubMed

    Larsen, Laurel G; Choi, Jungyill; Nungesser, Martha K; Harvey, Judson W

    2012-12-01

    Quantifying hydrologic and ecological connectivity has contributed to understanding transport and dispersal processes and assessing ecosystem degradation or restoration potential. However, there has been little synthesis across disciplines. The growing field of ecohydrology and recent recognition that loss of hydrologic connectivity is leading to a global decline in biodiversity underscore the need for a unified connectivity concept. One outstanding need is a way to quantify directional connectivity that is consistent, robust to variations in sampling, and transferable across scales or environmental settings. Understanding connectivity in a particular direction (e.g., streamwise, along or across gradient, between sources and sinks, along cardinal directions) provides critical information for predicting contaminant transport, planning conservation corridor design, and understanding how landscapes or hydroscapes respond to directional forces like wind or water flow. Here we synthesize progress on quantifying connectivity and develop a new strategy for evaluating directional connectivity that benefits from use of graph theory in ecology and percolation theory in hydrology. The directional connectivity index (DCI) is a graph-theory based, multiscale metric that is generalizable to a range of different structural and functional connectivity applications. It exhibits minimal sensitivity to image rotation or resolution within a given range and responds intuitively to progressive, unidirectional change. Further, it is linearly related to the integral connectivity scale length--a metric common in hydrology that correlates well with actual fluxes--but is less computationally challenging and more readily comparable across different landscapes. Connectivity-orientation curves (i.e., directional connectivity computed over a range of headings) provide a quantitative, information-dense representation of environmental structure that can be used for comparison or detection of subtle differences in the physical-biological feedbacks driving pattern formation. Case-study application of the DCI to the Everglades in south Florida revealed that loss of directional hydrologic connectivity occurs more rapidly and is a more sensitive indicator of declining ecosystem function than other metrics (e.g., habitat area) used previously. Here and elsewhere, directional connectivity can provide insight into landscape drivers and processes, act as an early-warning indicator of environmental degradation, and serve as a planning tool or performance measure for conservation and restoration efforts.

  17. Directional connectivity in hydrology and ecology

    USGS Publications Warehouse

    Larsen, Laurel G.; Choi, Jungyill; Nungesser, Martha K.; Harvey, Judson W.

    2012-01-01

    Quantifying hydrologic and ecological connectivity has contributed to understanding transport and dispersal processes and assessing ecosystem degradation or restoration potential. However, there has been little synthesis across disciplines. The growing field of ecohydrology and recent recognition that loss of hydrologic connectivity is leading to a global decline in biodiversity underscore the need for a unified connectivity concept. One outstanding need is a way to quantify directional connectivity that is consistent, robust to variations in sampling, and transferable across scales or environmental settings. Understanding connectivity in a particular direction (e.g., streamwise, along or across gradient, between sources and sinks, along cardinal directions) provides critical information for predicting contaminant transport, planning conservation corridor design, and understanding how landscapes or hydroscapes respond to directional forces like wind or water flow. Here we synthesize progress on quantifying connectivity and develop a new strategy for evaluating directional connectivity that benefits from use of graph theory in ecology and percolation theory in hydrology. The directional connectivity index (DCI) is a graph-theory based, multiscale metric that is generalizable to a range of different structural and functional connectivity applications. It exhibits minimal sensitivity to image rotation or resolution within a given range and responds intuitively to progressive, unidirectional change. Further, it is linearly related to the integral connectivity scale length—a metric common in hydrology that correlates well with actual fluxes—but is less computationally challenging and more readily comparable across different landscapes. Connectivity-orientation curves (i.e., directional connectivity computed over a range of headings) provide a quantitative, information-dense representation of environmental structure that can be used for comparison or detection of subtle differences in the physical-biological feedbacks driving pattern formation. Case-study application of the DCI to the Everglades in south Florida revealed that loss of directional hydrologic connectivity occurs more rapidly and is a more sensitive indicator of declining ecosystem function than other metrics (e.g., habitat area) used previously. Here and elsewhere, directional connectivity can provide insight into landscape drivers and processes, act as an early-warning indicator of environmental degradation, and serve as a planning tool or performance measure for conservation and restoration efforts.

  18. [Association between acid reflux and esophageal dysmotility in patients with gastroesophageal reflux disease].

    PubMed

    Yi, Zhi-hui; Feng, Li; Wen, Mao-yao; Liu, Jian-rong; Yang, Li

    2014-05-01

    To investigate the association between esophageal motility and acid reflux in patients with gastroesophageal reflux disease (GERD). A total of 94 patients with typical reflux symptoms such as heartburn, regurgitation and chest pain, whose score (Sc) of reflux diagnostic questionnaire (RDQ) was greater than or equal to 12 were enrolled in the study. Each participant was evaluated by upper gastrointestinal endoscopy, high resolution manometry (HRM) of esophagus and 24 h esophageal pH monitoring. The participants were divided into groups of reflux esophagitis (RE) and non-erosive reflux disease (NERD) on the basis of endoscopy findings. The 24 h esophageal pH monitoring categorized participants into physiologic reflux (pH) and pathologic reflux (pH+). The characteristics of esophageal motility and acid reflux were compared between the two groups of participants. Lower but non-significant differences (P > 0.05) were found in pressure of lower esophageal sphincter (LESP), length of lower esophageal sphincter (LESL), esophageal contraction amplitude (CA), distal contractile integral (DCI) and effective peristalsis proportion (EPP) in the participants in the RE group compared with those in the NERD group. Participants in the RE group had significantly higher prevalence of reduced LESP (63.0% vs. 31.7%, P < 0.01) and hiatus hernia (HH) (37.0% vs. 14.3%, P < 0.05) than those in the NERD group, pH+ was more prevalent in the RE group than in the NERD group (63.0% vs. 17.5%, P < 0.01). Indicators of 24 h esophageal pH monitoring were significantly higher in participants in the RE group compared with those in the NERD group (P < 0.05). Participants with pH+ had significantly lower LESP, CA and higher HH and prevalence of reduced LESP compared with those with pH (P < 0.05). LESL, DCI and EPP were lower in those with pH+ compared with those with pH-, but without statistical significance (P > 0.05). RE is closely associated with acid reflux and hiatus hernia. Esophageal dysmotility is more likely to appear in patients with pH+. The interaction of acid reflux and esophageal dysmotility may play a role in GERD.

  19. Impacts of urban sprawl on the area of downtown lakes in a highly developing city on central China

    NASA Astrophysics Data System (ADS)

    Zhang, W.; Zhang, Y.

    2016-12-01

    Wuhan city in central China is full of water resources and numerous lakes are located. Downtown lakes have significant ecological value and ornamental value for urban inhabitants in Wuhan. Under the rapid process of urban sprawl, downtown lakes are occupied by impervious areas. This research uses Landsat images to extract land uses from 1991 to 2013 in Wuhan city , and attempts to find out how urban sprawl affects the water body area decline in space. Two largest downtown lakes in Wuhan city, Donghu Lake located in central city and Tangxunhu Lake located in suburbs, are taken as case study area. A direction change index (DCI) is proposed to evaluate the changes of a specific land use in different directions. The results reveal that two downtown lakes are undergoing rapid water body area decline from 1991 to 2013, with decline rate are -0.022 in Donghu watershed and -0.011 in Tangxunhu watershed. 68.26% and 62.50% of the reduced water body is occupied by built-up land in Donghu watershed and Tangxunhu watershed, respectively. According to DCI, the water body reduce is highly correlated with built-up land increase in all direction. Moreover, it is found that in the Donghu watershed the north-west part suffered significant water body area decline, which is close to central city. While in Tangxunhu watershed, the area of water body declined in north-west, south-west and north-east part, and the area obstructed from central city by the lake was suffering less water body area decline. It is concluded that the water body area of downtown lakes are highly affected by the process of urban sprawl, and the lakes in central districts trends to suffer higher descend than that of the downtown lake located in suburbs. Meanwhile, even for the same downtown lake, the area orientating and close to the central city may suffer more rapid decline than the area that does not orientate to the central city.

  20. Elevated intrabolus pressure identifies obstructive processes when integrated relaxation pressure is normal on esophageal high-resolution manometry.

    PubMed

    Quader, Farhan; Reddy, Chanakyaram; Patel, Amit; Gyawali, C Prakash

    2017-07-01

    Elevated integrated relaxation pressure (IRP) on esophageal high-resolution manometry (HRM) identifies obstructive processes at the esophagogastric junction (EGJ). Our aim was to determine whether intrabolus pressure (IBP) can identify structural EGJ processes when IRP is normal. In this observational cohort study, adult patients with dysphagia and undergoing HRM were evaluated for endoscopic evidence of structural EGJ processes (strictures, rings, hiatus hernia) in the setting of normal IRP. HRM metrics [IRP, distal contractile integral (DCI), distal latency (DL), IBP, and EGJ contractile integral (EGJ-CI)] were compared among 74 patients with structural EGJ findings (62.8 ± 1.6 yr, 67.6% women), 27 patients with normal EGD (52.9 ± 3.2 yr, 70.3% women), and 21 healthy controls (27.6 ± 0.6 yr, 52.4% women). Findings were validated in 85 consecutive symptomatic patients to address clinical utility. In the primary cohort, mean IBP (18.4 ± 0.9 mmHg) was higher with structural EGJ findings compared with dysphagia with normal EGD (13.5 ± 1.1 mmHg, P = 0.002) and healthy controls (10.9 ± 0.9 mmHg, P < 0.001). However, mean IRP, DCI, DL, and EGJ-CI were similar across groups ( P > 0.05 for each comparison). During multiple rapid swallows, IBP remained higher in the structural findings group compared with controls ( P = 0.02). Similar analysis of the prospective validation cohort confirmed IBP elevation in structural EGJ processes, but correlation with dysphagia could not be demonstrated. We conclude that elevated IBP predicts the presence of structural EGJ processes even when IRP is normal, but correlation with dysphagia is suboptimal. NEW & NOTEWORTHY Integrated relaxation pressure (IRP) above the upper limit of normal defines esophageal outflow obstruction using high-resolution manometry. In patients with normal IRP, elevated intrabolus pressure (IBP) can be a surrogate marker for a structural restrictive or obstructive process at the esophagogastric junction (EGJ). This has the potential to augment the clinical value of esophageal HRM by raising suspicion for a structural EGJ process when IBP is elevated.

  1. Flux amplification and sustainment of ST plasmas by multi-pulsed coaxial helicity injection on HIST

    NASA Astrophysics Data System (ADS)

    Higashi, T.; Ishihara, M.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2010-11-01

    The Helicity Injected Spherical Torus (HIST) device has been developed towards high-current start up and sustainment by Multi-pulsed Coaxial Helicity Injection (M-CHI) method. Multiple pulses operation of the coaxial plasma gun can build the magnetic field of STs and spheromak plasmas in a stepwise manner. So far, successive gun pulses on SSPX at LLNL were demonstrated to maintain the magnetic field of spheromak in a quasi-steady state against resistive decay [1]. The resistive 3D-MHD numerical simulation [2] for STs reproduced the current amplification by the M-CHI method and confirmed that stochastic magnetic field was reduced during the decay phase. By double pulsed operation on HIST, the plasma current was effectively amplified against the resistive decay. The life time increases up to 10 ms which is longer than that in the single CHI case (4 ms). The edge poloidal fields last between 0.5 ms and 6 ms like a repetitive manner. During the second driven phase, the toroidal ion flow is driven in the same direction as the plasma current as well as in the initial driven phase. At the meeting, we will discuss a current amplification mechanism based on the merging process with the plasmoid injected secondly from the gun. [1] B. Hudson et al., Phys. Plasmas Vol.15, 056112 (2008). [2] Y. Kagei et al., J. Plasma Fusion Res. Vol.79, 217 (2003).

  2. Fungicide Injection to Control Dutch Elm Disease: Understanding the Options

    Treesearch

    Linda Haugen; Mark Stennes

    1999-01-01

    In some situations, injecting trees with fungicides is an effective treatment for the management of Dutch elm disease (DED). Several injection products are on the market, and various means of application are recommended. Each product and method has pros and cons. The "best" product depends on the individual tree? its current condition, the objectives of the...

  3. The Helicity Injected Torus Program

    NASA Astrophysics Data System (ADS)

    Jarboe, T. R.; Nelson, B. A.; Jewell, P. D.; Liptac, J. E.; McCollam, K. J.; Raman, R.; Redd, A. J.; Rogers, J. A.; Sieck, P. E.; Shumlak, U.; Smith, R. J.; Nagata, M.; Uyama, T.

    1999-11-01

    The Helicity Injected Torus--II (HIT--II) spherical torus is capable of both Coaxial Helicity Injection (CHI) and transformer action current drive. HIT--II has a major radius R = 0.3, minor radius a = 0.2, aspect ratio A = R/a = 1.5, with an on axis magnetic field of up to Bo = 0.67 T. HIT--II provides equilibrium control, CHI flux boundary conditions, and transformer action using 28 poloidal field coils, using active flux feedback control. HIT--II has driven up to 200 kA of plasma current, using either CHI or transformer drive. An overview and recent results of the HIT--II program will be presented. The development of a locked-electron current drive model for HIT and HIT--II has led to the design of a constant inductive helicity injection method for spherical torii. This method is incorporated in the design of the Helicity Injected Torus -- Steady Inductive (HIT-- SI)(T.R. Jarboe, Fusion Technology, 36) (1), p. 85, 1999 experiment. HIT--SI can form a high-beta spheromak, a low aspect ratio RFP, or a spherical tokamak in a steady-state manner without using electrodes. The HIT--SI design and methodology will be presented.

  4. Design of the Helicity Injected Torus with Steady Inductive Helicity Injection (HIT-SI)

    NASA Astrophysics Data System (ADS)

    Sieck, P. E.; Gu, P.; Hamp, W. T.; Izzo, V. A.; McCollam, K. J.; Jarboe, T. R.; Nelson, B. A.; Redd, A. J.; Rogers, J. A.; Shumlak, U.

    2000-10-01

    Steady Inductive Helicity Injection (SIHI) is an inductive current drive method that injects helicity at a nearly constant rate, without open field lines, and without removing any helicity or magnetic energy from the plasma(T.R. Jarboe, Fusion Technology 36), p. 85, 1999. SIHI directly produces a rotating magnetic field structure, and the current profile is nearly time independent in the frame of the rotating field. The Helicity Injected Torus with SIHI (HIT-SI) is a ``bow tie'' spheromak designed to implement SIHI so that the current profile in the rotating frame is optimized. SIHI is accomplished using two inductive helicity injectors that operate 90^o out of phase with each other. Each helicity injector is a 180^o segment of a ZT-P size (a ≈ 8cm, R ≈ 32cm) RFP. The presence of a spheromak equilibrium will be readily apparent on several diagnostics, including the surface magnetic probes. The design of HIT-SI is presented, including the manufacturing techniques and metallurgical processes being used in the construction of the one-meter diameter close-fitting flux conserver. Several small prototype tests have been performed to prove the vacuum seal and electrical insulation capabilities of the design, and a finite element stress analysis of the flux conserver will be presented.

  5. A simulation study of interactions of space-shuttle generated electron beams with ambient plasma and neutral gas

    NASA Technical Reports Server (NTRS)

    Winglee, Robert M.

    1991-01-01

    The objective was to conduct large scale simulations of electron beams injected into space. The study of the active injection of electron beams from spacecraft is important, as it provides valuable insight into the plasma beam interactions and the development of current systems in the ionosphere. However, the beam injection itself is not simple, being constrained by the ability of the spacecraft to draw current from the ambient plasma. The generation of these return currents is dependent on several factors, including the density of the ambient plasma relative to the beam density, the presence of neutrals around the spacecraft, the configuration of the spacecraft, and the motion of the spacecraft through the plasma. Two dimensional (three velocity) particle simulations with collisional processes included are used to show how these different and often coupled processes can be used to enhance beam propagation from the spacecraft. To understand the radial expansion mechanism of an electron beam injected from a highly charged spacecraft, two dimensional particle-in-cell simulations were conducted for a high density electron beam injected parallel to magnetic fields from an isolated equipotential conductor into a cold background plasma. The simulations indicate that charge build-up at the beam stagnation point causes the beam to expand radially to the beam electron gyroradius.

  6. Injectable scaffolds: Preparation and application in dental and craniofacial regeneration

    PubMed Central

    Chang, Bei; Ahuja, Neelam; Ma, Chi; Liu, Xiaohua

    2016-01-01

    Injectable scaffolds are appealing for tissue regeneration because they offer many advantages over pre-formed scaffolds. This article provides a comprehensive review of the injectable scaffolds currently being investigated for dental and craniofacial tissue regeneration. First, we provide an overview of injectable scaffolding materials, including natural, synthetic, and composite biomaterials. Next, we discuss a variety of characteristic parameters and gelation mechanisms of the injectable scaffolds. The advanced injectable scaffolding systems developed in recent years are then illustrated. Furthermore, we summarize the applications of the injectable scaffolds for the regeneration of dental and craniofacial tissues that include pulp, dentin, periodontal ligament, temporomandibular joint, and alveolar bone. Finally, our perspectives on the injectable scaffolds for dental and craniofacial tissue regeneration are offered as signposts for the future advancement of this field. PMID:28649171

  7. Advances in cardiac CT contrast injection and acquisition protocols.

    PubMed

    Scholtz, Jan-Erik; Ghoshhajra, Brian

    2017-10-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.

  8. Advances in cardiac CT contrast injection and acquisition protocols

    PubMed Central

    Scholtz, Jan-Erik

    2017-01-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors. PMID:29255688

  9. Variable N-type negative resistance in an injection-gated double-injection diode

    NASA Technical Reports Server (NTRS)

    Kapoor, A. K.; Henderson, H. T.

    1981-01-01

    Double-injection (DI) switching devices consist of p+ and n+ contacts (for hole and electron injection, respectively), separated by a near intrinsic semiconductor region containing deep traps. Under proper conditions, these devices exhibit S-type differential negative resistance (DNR) similar to silicon-controlled rectifiers. With the added influence of a p+ gate appropriately placed between the anode (p+) and cathode (n+), the current-voltage characteristic of the device has been manipulated for the first time to exhibit a variable N-type DNR. The anode current and the anode-to-cathode voltage levels at which this N-type DNR is observed can be varied by changing the gate-to-cathode bias. In essence, the classical S-type DI diode can be electronically transformed into an N-type diode. A first-order phenomenological model is proposed for the N-type DNR.

  10. Formation and termination of runaway beams in ITER disruptions

    NASA Astrophysics Data System (ADS)

    Martín-Solís, J. R.; Loarte, A.; Lehnen, M.

    2017-06-01

    A self-consistent analysis of the relevant physics regarding the formation and termination of runaway beams during mitigated disruptions by Ar and Ne injection is presented for selected ITER scenarios with the aim of improving our understanding of the physics underlying the runaway heat loads onto the plasma facing components (PFCs) and identifying open issues for developing and accessing disruption mitigation schemes for ITER. This is carried out by means of simplified models, but still retaining sufficient details of the key physical processes, including: (a) the expected dominant runaway generation mechanisms (avalanche and primary runaway seeds: Dreicer and hot tail runaway generation, tritium decay and Compton scattering of γ rays emitted by the activated wall), (b) effects associated with the plasma and runaway current density profile shape, and (c) corrections to the runaway dynamics to account for the collisions of the runaways with the partially stripped impurity ions, which are found to have strong effects leading to low runaway current generation and low energy conversion during current termination for mitigated disruptions by noble gas injection (particularly for Ne injection) for the shortest current quench times compatible with acceptable forces on the ITER vessel and in-vessel components ({τ\\text{res}}∼ 22~\\text{ms} ). For the case of long current quench times ({τ\\text{res}}∼ 66~\\text{ms} ), runaway beams up to  ∼10 MA can be generated during the disruption current quench and, if the termination of the runaway current is slow enough, the generation of runaways by the avalanche mechanism can play an important role, increasing substantially the energy deposited by the runaways onto the PFCs up to a few hundreds of MJs. Mixed impurity (Ar or Ne) plus deuterium injection proves to be effective in controlling the formation of the runaway current during the current quench, even for the longest current quench times, as well as in decreasing the energy deposited on the runaway electrons during current termination.

  11. Preferential acceleration and magnetic field enhancement in plasmas with e{sup +}/e{sup −} beam injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huynh, Cong Tuan; Ryu, Chang-Mo, E-mail: ryu201@postech.ac.kr

    A theoretical model of current filaments predicting preferential acceleration/deceleration and magnetic field enhancement in a plasma with e{sup +}/e{sup −} beam injection is presented. When the e{sup +}/e{sup −} beams are injected into a plasma, current filaments are formed. The beam particles are accelerated or decelerated depending on the types of current filaments in which they are trapped. It is found that in the electron/ion ambient plasma, the e{sup +} beam particles are preferentially accelerated, while the e{sup −} beam particles are preferentially decelerated. The preferential particle acceleration/deceleration is absent when the ambient plasma is the e{sup +}/e{sup −} plasma.more » We also find that the particle momentum decrease can explain the magnetic field increase during the development of Weibel/filamentation instability. Supporting simulation results of particle acceleration/deceleration and magnetic field enhancement are presented. Our findings can be applied to a wide range of astrophysical plasmas with the e{sup +}/e{sup −} beam injection.« less

  12. Large spin current injection in nano-pillar-based lateral spin valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nomura, Tatsuya; Ohnishi, Kohei; Kimura, Takashi, E-mail: t-kimu@phys.kyushu-u.ac.jp

    We have investigated the influence of the injection of a large pure spin current on a magnetization process of a non-locally located ferromagnetic dot in nano-pillar-based lateral spin valves. Here, we prepared two kinds of the nano-pillar-type lateral spin valve based on Py nanodots and CoFeAl nanodots fabricated on a Cu film. In the Py/Cu lateral spin valve, although any significant change of the magnetization process of the Py nanodot has not been observed at room temperature. The magnetization reversal process is found to be modified by injecting a large pure spin current at 77 K. Switching the magnetization bymore » the nonlocal spin injection has also been demonstrated at 77 K. In the CoFeAl/Cu lateral spin valve, a room temperature spin valve signal was strongly enhanced from the Py/Cu lateral spin valve because of the highly spin-polarized CoFeAl electrodes. The room temperature nonlocal switching has been demonstrated in the CoFeAl/Cu lateral spin valve.« less

  13. Silk hydrogels for sustained ocular delivery of anti-vascular endothelial growth factor (anti-VEGF) therapeutics.

    PubMed

    Lovett, Michael L; Wang, Xiaoqin; Yucel, Tuna; York, Lyndsey; Keirstead, Marc; Haggerty, Linda; Kaplan, David L

    2015-09-01

    Silk hydrogels were formulated with anti-vascular endothelial growth factor (anti-VEGF) therapeutics for sustained ocular drug delivery. Using silk fibroin as a vehicle for delivery, bevacizumab-loaded hydrogel formulations demonstrated sustained release of 3 months or greater in experiments in vitro as well as in vivo using an intravitreal injection model in Dutch-belted rabbits. Using both standard dose (1.25mg bevacizumab/50 μL injection) and high dose (5.0mg bevacizumab/50 μL injection) hydrogel formulations, release concentrations were achieved at day 90 that were equivalent or greater than those achieved at day 30 with the positive standard dose control (single injection (50 μL) of 1.25mg bevacizumab solution), which is estimated to be the therapeutic threshold based on the current dosage administration schedule of 1 injection/month. These gels also demonstrated signs of biodegradation after 3 months, suggesting that repeated injections may be possible (e.g., one injection every 3-6 months or longer). Due to its pharmacokinetic and biodegradation profiles, this delivery system may be used to reduce the frequency of dosing for patients currently enduring treatment using bevacizumab or other anti-VEGF therapeutics. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Dynamic Control of the Vortex Pinning Potential in a Superconductor Using Current Injection through Nanoscale Patterns.

    PubMed

    Kalcheim, Yoav; Katzir, Eran; Zeides, Felix; Katz, Nadav; Paltiel, Yossi; Millo, Oded

    2017-05-10

    Control over the vortex potential at the nanoscale in a superconductor is a subject of great interest for both fundamental and technological reasons. Many methods for achieving artificial pinning centers have been demonstrated, for example, with magnetic nanostructures or engineered imperfections, yielding many intriguing effects. However, these pinning mechanisms do not offer dynamic control over the strength of the patterned vortex potential because they involve static nanostructures created in or near the superconductor. Dynamic control has been achieved with scanning probe methods on the single vortex level but these are difficult so scale up. Here, we show that by applying controllable nanopatterned current injection, the superconductor can be locally driven out of equilibrium, creating an artificial vortex potential that can be tuned by the magnitude of the injected current, yielding a unique vortex channeling effect.

  15. Effects of intracellular injection of calcium buffers on light adaptation in Limulus ventral photoreceptors

    PubMed Central

    1975-01-01

    The calcium sequestering agent, EGTA, was injected into Limulus ventral photoreceptors. Before injection, the inward membrane current induced by a long stimulus had a large initial transient which declined to a smaller plateau. Iontophoretic injection of EGTA tended to prevent the decline from transient to plateau. Before injection the plateau response was a nonlinear function of light intensity. After EGTA injection the response-intensity curves tended to become linear. Before injection, bright lights lowered the sensitivity as determined with subsequent test flashes. EGTA injection decreased the light-induced changes in sensitivity. Ca-EGTA buffers having different levels of free calcium were pressure-injected into ventral photoreceptors; the higher the level of free calcium, the lower the sensitivity measured after injection. The effects of inotophoretic injection of EGTA were not mimicked by injection or similar amounts of sulfate and the effects of pressure injection of EGTA buffer solutions were not mimicked by injection of similar volumes of pH buffer or mannitol. The data are consistent with the hypothesis that light adaptation is mediated by a rise of the intracellular free calcium concentration. PMID:810540

  16. Integrated semiconductor twin-microdisk laser under mutually optical injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, Ling-Xiu; Liu, Bo-Wen; Lv, Xiao-Meng

    2015-05-11

    We experimentally study the characteristics of an integrated semiconductor twin-microdisk laser under mutually optical injection through a connected optical waveguide. Based on the lasing spectra, four-wave mixing, injection locking, and period-two oscillation states are observed due to the mutually optical injection by adjusting the injected currents applied to the two microdisks. The enhanced 3 dB bandwidth is realized for the microdisk laser at the injection locking state, and photonic microwave is obtained from the electrode of the microdisk laser under the period-two oscillation state. The plentifully dynamical states similar as semiconductor lasers subject to external optical injection are realized due tomore » strong optical interaction between the two microdisks.« less

  17. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Injection lasers based on the AlGaAsSb system emitting at 1.6 μm

    NASA Astrophysics Data System (ADS)

    Virro, A. L.; Eliseev, P. G.; Lyuk, P. A.; Fridental, Ya K.; Khaller, Yu E.

    1988-11-01

    An experimental dependence of the threshold current density jth on the thickness of the active region was used to find the reduced threshold current density for AlGaAsSb (λ = 1.59μm, T = 295K) lasers: this density was 8 kA·cm-2·μm-1. The minimum threshold current was jth = 1.8 kA/cm2. Wide-contact lasers exhibited cw operation down to 175 K.

  18. Current-induced switching in a magnetic insulator

    NASA Astrophysics Data System (ADS)

    Avci, Can Onur; Quindeau, Andy; Pai, Chi-Feng; Mann, Maxwell; Caretta, Lucas; Tang, Astera S.; Onbasli, Mehmet C.; Ross, Caroline A.; Beach, Geoffrey S. D.

    2017-03-01

    The spin Hall effect in heavy metals converts charge current into pure spin current, which can be injected into an adjacent ferromagnet to exert a torque. This spin-orbit torque (SOT) has been widely used to manipulate the magnetization in metallic ferromagnets. In the case of magnetic insulators (MIs), although charge currents cannot flow, spin currents can propagate, but current-induced control of the magnetization in a MI has so far remained elusive. Here we demonstrate spin-current-induced switching of a perpendicularly magnetized thulium iron garnet film driven by charge current in a Pt overlayer. We estimate a relatively large spin-mixing conductance and damping-like SOT through spin Hall magnetoresistance and harmonic Hall measurements, respectively, indicating considerable spin transparency at the Pt/MI interface. We show that spin currents injected across this interface lead to deterministic magnetization reversal at low current densities, paving the road towards ultralow-dissipation spintronic devices based on MIs.

  19. Extraction-controlled terahertz frequency quantum cascade lasers with a diagonal LO-phonon extraction and injection stage.

    PubMed

    Han, Y J; Li, L H; Grier, A; Chen, L; Valavanis, A; Zhu, J; Freeman, J R; Isac, N; Colombelli, R; Dean, P; Davies, A G; Linfield, E H

    2016-12-12

    We report an extraction-controlled terahertz (THz)-frequency quantum cascade laser design in which a diagonal LO-phonon scattering process is used to achieve efficient current injection into the upper laser level of each period and simultaneously extract electrons from the adjacent period. The effects of the diagonality of the radiative transition are investigated, and a design with a scaled oscillator strength of 0.45 is shown experimentally to provide the highest temperature performance. A 3.3 THz device processed into a double-metal waveguide configuration operated up to 123 K in pulsed mode, with a threshold current density of 1.3 kA/cm2 at 10 K. The QCL structures are modeled using an extended density matrix approach, and the large threshold current is attributed to parasitic current paths associated with the upper laser levels. The simplicity of this design makes it an ideal platform to investigate the scattering injection process.

  20. Large-volume flux closure during plasmoid-mediated reconnection in coaxial helicity injection

    DOE Data Explorer

    Ebrahimi, Fatima [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)] (ORCID:0000000331095367); Raman, Roger [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)] (ORCID:0000000220273271)

    2016-01-01

    A large-volume flux closure during transient coaxial helicity injection (CHI) in NSTX-U is demonstrated through resistive magnetohydrodynamics (MHD) simulations. Several major improvements, including the improved positioning of the divertor poloidal field coils, are projected to improve the CHI start-up phase in NSTX-U. Simulations in the NSTX-U configuration with constant in time coil currents show that with strong flux shaping the injected open field lines (injector flux) rapidly reconnect and form large volume of closed flux surfaces. This is achieved by driving parallel current in the injector flux coil and oppositely directed currents in the flux shaping coils to form a narrow injector flux footprint and push the injector flux into the vessel. As the helicity and plasma are injected into the device, the oppositely directed field lines in the injector region are forced to reconnect through a local Sweet–Parker type reconnection, or to spontaneously reconnect when the elongated current sheet becomes MHD unstable to form plasmoids. In these simulations for the first time, it is found that the closed flux is over 70% of the initial injector flux used to initiate the discharge. These results could work well for the application of transient CHI in devices that employ super conducting coils to generate and sustain the plasma equilibrium.

  1. Large-volume flux closure during plasmoid-mediated reconnection in coaxial helicity injection

    DOE Data Explorer

    Ebrahimi, F. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Raman, R. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)

    2016-04-01

    A large-volume flux closure during transient coaxial helicity injection (CHI) in NSTX-U is demonstrated through resistive magnetohydrodynamics (MHD) simulations. Several major improvements, including the improved positioning of the divertor poloidal field coils, are projected to improve the CHI start-up phase in NSTX-U. Simulations in the NSTX-U configuration with constant in time coil currents show that with strong flux shaping the injected open field lines (injector flux) rapidly reconnect and form large volume of closed flux surfaces. This is achieved by driving parallel current in the injector flux coil and oppositely directed currents in the flux shaping coils to form a narrow injector flux footprint and push the injector flux into the vessel. As the helicity and plasma are injected into the device, the oppositely directed field lines in the injector region are forced to reconnect through a local Sweet–Parker type reconnection, or to spontaneously reconnect when the elongated current sheet becomes MHD unstable to form plasmoids. In these simulations for the first time, it is found that the closed flux is over 70% of the initial injector flux used to initiate the discharge. These results could work well for the application of transient CHI in devices that employ super conducting coils to generate and sustain the plasma equilibrium.

  2. Monitoring method and apparatus using high-frequency carrier

    DOEpatents

    Haynes, Howard D.

    1996-01-01

    A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device.

  3. Optimization of the multi-turn injection efficiency for a medical synchrotron

    NASA Astrophysics Data System (ADS)

    Kim, J.; Yoon, M.; Yim, H.

    2016-09-01

    We present a method for optimizing the multi-turn injection efficiency for a medical synchrotron. We show that for a given injection energy, the injection efficiency can be greatly enhanced by choosing transverse tunes appropriately and by optimizing the injection bump and the number of turns required for beam injection. We verify our study by applying the method to the Korea Heavy Ion Medical Accelerator (KHIMA) synchrotron which is currently being built at the campus of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Busan, Korea. First the frequency map analysis was performed with the help of the ELEGANT and the ACCSIM codes. The tunes that yielded good injection efficiency were then selected. With these tunes, the injection bump and the number of turns required for injection were then optimized by tracking a number of particles for up to one thousand turns after injection, beyond which no further beam loss occurred. Results for the optimization of the injection efficiency for proton ions are presented.

  4. Calculation of prompt loss and toroidal field ripple loss under neutral beam injection on EAST

    NASA Astrophysics Data System (ADS)

    Wu, Bin; Hao, Baolong; White, Roscoe; Wang, Jinfang; Zang, Qing; Han, Xiaofeng; Hu, Chundong

    2017-02-01

    Neutral beam injection is a major auxiliary heating method in the EAST experimental campaign. This paper gives detailed calculations of beam loss with different plasma equilibria using the guiding center code ORBIT and NUBEAM/TRANSP. Increasing plasma current can dramatically lower the beam ion prompt loss and ripple loss. Countercurrent beam injection gives a much larger prompt loss fraction than co-injection, and ripple-induced collisionless stochastic diffusion is the dominant loss channel.

  5. Calculation of prompt loss and toroidal field ripple loss under neutral beam injection on EAST

    DOE PAGES

    Wu, Bin; Hao, Baolong; White, Roscoe; ...

    2016-12-09

    Here, neutral beam injection is a major auxiliary heating method in the EAST experimental campaign. This paper gives detailed calculations of beam loss with different plasma equilibria using the guiding center code ORBIT and NUBEAM/TRANSP. Increasing plasma current can dramatically lower the beam ion prompt loss and ripple loss. Countercurrent beam injection gives a much larger prompt loss fraction than co-injection, and ripple-induced collisionless stochastic diffusion is the dominant loss channel.

  6. Calculation of prompt loss and toroidal field ripple loss under neutral beam injection on EAST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Bin; Hao, Baolong; White, Roscoe

    Here, neutral beam injection is a major auxiliary heating method in the EAST experimental campaign. This paper gives detailed calculations of beam loss with different plasma equilibria using the guiding center code ORBIT and NUBEAM/TRANSP. Increasing plasma current can dramatically lower the beam ion prompt loss and ripple loss. Countercurrent beam injection gives a much larger prompt loss fraction than co-injection, and ripple-induced collisionless stochastic diffusion is the dominant loss channel.

  7. Charge Injection Capacity of TiN Electrodes for an Extended Voltage Range

    PubMed Central

    Patan, Mustafa; Shah, Tosha; Sahin, Mesut

    2011-01-01

    Many applications of neural stimulation demand a high current density from the electrodes used for stimulus delivery. New materials have been searched that can provide such large current and charge densities where the traditional noble metal and capacitor electrodes are inadequate. Titanium nitride, which has been used in cardiac pacemaker leads for many years, is one of these materials recently considered for neural stimulation. In this short report, we investigated the charge injection capacity of TiN electrodes for an extended range of cathodic voltages. The injected charge increased first slowly as a function of the electrode voltage, and then at a faster rate beyond −1.6 V. The maximum charge was 4.45 mC/cm2 (n=6) for a cathodic voltage peak of −3.0 V and a bias voltage of −0.8 V. There was no evidence of bubble generation under microscopic observation. The unrecoverable charges remained under 7% of the total injected charge for the largest cathodic voltage tested. These large values of charge injection capacity and relatively small unrecoverable charges warrant further investigation of the charge injection mechanism in TiN interfaces at this extended range of electrode voltages. PMID:17946870

  8. Shear Alfven Wave Injection in the Magnetosphere by Ionospheric Modifications in the Absence of Electrojet Currents

    NASA Astrophysics Data System (ADS)

    Papadopoulos, K.; Eliasson, B.; Shao, X.; Labenski, J.; Chang, C.

    2011-12-01

    A new concept of generating ionospheric currents in the ULF/ELF range with modulated HF heating using ground-based transmitters even in the absence of electrojet currents is presented. The new concept relies on using HF heating of the F-region to modulate the electron temperature and has been given the name Ionospheric Current Drive (ICD). In ICD, the pressure gradient associated with anomalous or collisional F-region electron heating drives a local diamagnetic current that acts as an antenna to inject mainly Magneto-Sonic (MS) waves in the ionospheric plasma. The electric field associated with the MS wave drives Hall currents when it reaches the E region of the ionosphere. The Hall currents act as a secondary antenna that inject waves in the Earth-Ionosphere Waveguide (EIW) below and shear Alfven waves or EMIC waves upwards towards the conjugate regions. The paper presents: (i) Theoretical results using a cold Hall MHD model to study ICD and the generation of ULF/ELF waves by the modulation of the electron pressure at the F2-region with an intense HF electromagnetic wave. The model solves equations governing the dynamics of the shear Alfven and magnetosonic modes, of the damped modes in the diffusive Pedersen layer, and of the weakly damped helicon wave mode in the Hall-dominated E-region. The model incorporates realistic profile of the ionospheric conductivities and magnetic field configuration. We use the model to simulate propagation and dynamics of the low-frequency waves and their injection into the magnetosphere from the HAARP and Arecibo ionospheric heaters. (ii) Proof of principle experiments using the HAARP ionospheric heater in conjunction with measurements by the DEMETER satellite This work is supported by ONR MURI grant and DARPA BRIOCHE Program

  9. New technologies for HWIL testing of WFOV, large-format FPA sensor systems

    NASA Astrophysics Data System (ADS)

    Fink, Christopher

    2016-05-01

    Advancements in FPA density and associated wide-field-of-view infrared sensors (>=4000x4000 detectors) have outpaced the current-art HWIL technology. Whether testing in optical projection or digital signal injection modes, current-art technologies for infrared scene projection, digital injection interfaces, and scene generation systems simply lack the required resolution and bandwidth. For example, the L3 Cincinnati Electronics ultra-high resolution MWIR Camera deployed in some UAV reconnaissance systems features 16MP resolution at 60Hz, while the current upper limit of IR emitter arrays is ~1MP, and single-channel dual-link DVI throughput of COTs graphics cards is limited to 2560x1580 pixels at 60Hz. Moreover, there are significant challenges in real-time, closed-loop, physics-based IR scene generation for large format FPAs, including the size and spatial detail required for very large area terrains, and multi - channel low-latency synchronization to achieve the required bandwidth. In this paper, the author's team presents some of their ongoing research and technical approaches toward HWIL testing of large-format FPAs with wide-FOV optics. One approach presented is a hybrid projection/injection design, where digital signal injection is used to augment the resolution of current-art IRSPs, utilizing a multi-channel, high-fidelity physics-based IR scene simulator in conjunction with a novel image composition hardware unit, to allow projection in the foveal region of the sensor, while non-foveal regions of the sensor array are simultaneously stimulated via direct injection into the post-detector electronics.

  10. Resonant interaction of the electron beam with a synchronous wave in controlled magnetrons for high-current superconducting accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kazakevich, G.; Johnson, R.; Lebedev, V.

    A simplified analytical model of the resonant interaction of the beam of Larmor electrons drifting in the crossed constant fields of a magnetron with a synchronous wave providing a phase grouping of the drifting charge was developed to optimize the parameters of an rf resonant injected signal driving the magnetrons for management of phase and power of rf sources with a rate required for superconducting high-current accelerators. The model, which considers the impact of the rf resonant signal injected into the magnetron on the operation of the injection-locked tube, substantiates the recently developed method of fast power control of magnetronsmore » in the range up to 10 dB at the highest generation efficiency, with low noise, precise stability of the carrier frequency, and the possibility of wideband phase control. Experiments with continuous wave 2.45 GHz, 1 kW microwave oven magnetrons have verified the correspondence of the behavior of these tubes to the analytical model. A proof of the principle of the novel method of power control in magnetrons, based on the developed model, was demonstrated in the experiments. The method is attractive for high-current superconducting rf accelerators. This study also discusses vector methods of power control with the rates required for superconducting accelerators, the impact of the rf resonant signal injected into the magnetron on the rate of phase control of the injection-locked tubes, and a conceptual scheme of the magnetron transmitter with highest efficiency for high-current accelerators.« less

  11. Resonant interaction of the electron beam with a synchronous wave in controlled magnetrons for high-current superconducting accelerators

    DOE PAGES

    Kazakevich, G.; Johnson, R.; Lebedev, V.; ...

    2018-06-14

    A simplified analytical model of the resonant interaction of the beam of Larmor electrons drifting in the crossed constant fields of a magnetron with a synchronous wave providing a phase grouping of the drifting charge was developed to optimize the parameters of an rf resonant injected signal driving the magnetrons for management of phase and power of rf sources with a rate required for superconducting high-current accelerators. The model, which considers the impact of the rf resonant signal injected into the magnetron on the operation of the injection-locked tube, substantiates the recently developed method of fast power control of magnetronsmore » in the range up to 10 dB at the highest generation efficiency, with low noise, precise stability of the carrier frequency, and the possibility of wideband phase control. Experiments with continuous wave 2.45 GHz, 1 kW microwave oven magnetrons have verified the correspondence of the behavior of these tubes to the analytical model. A proof of the principle of the novel method of power control in magnetrons, based on the developed model, was demonstrated in the experiments. The method is attractive for high-current superconducting rf accelerators. This study also discusses vector methods of power control with the rates required for superconducting accelerators, the impact of the rf resonant signal injected into the magnetron on the rate of phase control of the injection-locked tubes, and a conceptual scheme of the magnetron transmitter with highest efficiency for high-current accelerators.« less

  12. Follow up of injected polyurethane slab jacking.

    DOT National Transportation Integrated Search

    2003-08-01

    GLENN JACKSON BRIDGE FOLLOW-UP REPORT The elevation monitoring in the report entitled Injected Polyurethane Slab Jacking (Soltesz 2000) is continued in this current report. The elevations of the concrete slabs are being monitored to see if polyuretha...

  13. Effect of Axially Staged Fuel Introduction on Performance of One-quarter Sector of Annular Turbojet Combustor

    NASA Technical Reports Server (NTRS)

    Zettle, Eugene V; Mark, Herman

    1953-01-01

    The design principle of injecting liquid fuel at more than one axial station in an annual turbojet combustor was investigated. Fuel was injected into the combustor as much as 5 inches downstream of the primary fuel injectors. Many fuel-injection configurations were examined and the performance results are presented for 11 configurations that best demonstrate the trends in performance obtained. The performance investigations were made at a constant combustor-inlet pressure of 15 inches of mercury absolute and at air flows up to 70 percent higher than values typical of current design practice. At these higher air flows, staging the fuel introduction improved the combustion efficiency considerably over that obtained in the combustor when no fuel staging was employed. At air flows currently encountered in turbojet engines, fuel staging was of minor value. Radial temperature distribution seemed relatively unaffected by the location of fuel-injection stations.

  14. Signal injection as a fault detection technique.

    PubMed

    Cusidó, Jordi; Romeral, Luis; Ortega, Juan Antonio; Garcia, Antoni; Riba, Jordi

    2011-01-01

    Double frequency tests are used for evaluating stator windings and analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor Current Signature Analysis (MCSA), which focuses on the spectral analysis of stator current, is the most widely used method for identifying faults in induction motors. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes the injection of an additional voltage into the machine being tested at a frequency different from the fundamental one, and then studying the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequencies.

  15. The effects of interfacial recombination and injection barrier on the electrical characteristics of perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Shi, Lin Xing; Wang, Zi Shuai; Huang, Zengguang; Sha, Wei E. I.; Wang, Haoran; Zhou, Zhen

    2018-02-01

    Charge carrier recombination in the perovskite solar cells (PSCs) has a deep influence on the electrical performance, such as open circuit voltage, short circuit current, fill factor and ultimately power conversion efficiency. The impacts of injection barrier, recombination channels, doping properties of carrier transport layers and light intensity on the performance of PSCs are theoretically investigated by drift-diffusion model in this work. The results indicate that due to the injection barrier at the interfaces of perovskite and carrier transport layer, the accumulated carriers modify the electric field distribution throughout the PSCs. Thus, a zero electric field is generated at a specific applied voltage, with greatly increases the interfacial recombination, resulting in a local kink of current density-voltage (J-V) curve. This work provides an effective strategy to improve the efficiency of PSCs by pertinently reducing both the injection barrier and interfacial recombination.

  16. The Hyaluronic Acid Fillers: Current Understanding of the Tissue Device Interface.

    PubMed

    Greene, Jacqueline J; Sidle, Douglas M

    2015-11-01

    The article is a detailed update regarding cosmetic injectable fillers, specifically focusing on hyaluronic acid fillers. Hyaluronic acid-injectable fillers are used extensively for soft tissue volumizing and contouring. Many different hyaluronic acid-injectable fillers are available on the market and differ in terms of hyaluronic acid concentration, particle size, cross-linking density, requisite needle size, duration, stiffness, hydration, presence of lidocaine, type of cross-linking technology, and cost. Hyaluronic acid is a natural component of many soft tissues, is identical across species minimizing immunogenicity has been linked to wound healing and skin regeneration, and is currently actively being studied for tissue engineering purposes. The biomechanical and biochemical effects of HA on the local microenvironment of the injected site are key to its success as a soft tissue filler. Knowledge of the tissue-device interface will help guide the facial practitioner and lead to optimal outcomes for patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Signal Injection as a Fault Detection Technique

    PubMed Central

    Cusidó, Jordi; Romeral, Luis; Ortega, Juan Antonio; Garcia, Antoni; Riba, Jordi

    2011-01-01

    Double frequency tests are used for evaluating stator windings and analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor Current Signature Analysis (MCSA), which focuses on the spectral analysis of stator current, is the most widely used method for identifying faults in induction motors. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes the injection of an additional voltage into the machine being tested at a frequency different from the fundamental one, and then studying the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequencies. PMID:22163801

  18. Optical bistability in erbium-doped yttrium aluminum garnet crystal combined with a laser diode.

    PubMed

    Maeda, Y

    1994-01-10

    Optical bistability was observed in a simple structure of an injection laser diode combined with an erbium-doped yttrium aluminum garnet crystal. Since a hysteresis characteristic exists in the relationship between the wavelength and the injection current of a laser diode, an optical memory function capable of holding the output status is confirmed. In addition, an optical signal inversion was caused by the decrease of transmission of the erbium-doped yttrium aluminum garnet crystal against the red shift (principally mode hopping) of the laser diode. It is suggested that the switching time of this phenomenon is the time necessary for a mode hopping by current injection.

  19. Optical double-locked semiconductor lasers

    NASA Astrophysics Data System (ADS)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  20. Induced seismicity provides insight into why earthquake ruptures stop.

    PubMed

    Galis, Martin; Ampuero, Jean Paul; Mai, P Martin; Cappa, Frédéric

    2017-12-01

    Injection-induced earthquakes pose a serious seismic hazard but also offer an opportunity to gain insight into earthquake physics. Currently used models relating the maximum magnitude of injection-induced earthquakes to injection parameters do not incorporate rupture physics. We develop theoretical estimates, validated by simulations, of the size of ruptures induced by localized pore-pressure perturbations and propagating on prestressed faults. Our model accounts for ruptures growing beyond the perturbed area and distinguishes self-arrested from runaway ruptures. We develop a theoretical scaling relation between the largest magnitude of self-arrested earthquakes and the injected volume and find it consistent with observed maximum magnitudes of injection-induced earthquakes over a broad range of injected volumes, suggesting that, although runaway ruptures are possible, most injection-induced events so far have been self-arrested ruptures.

  1. Room-Temperature Spin Polariton Diode Laser

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Aniruddha; Baten, Md Zunaid; Iorsh, Ivan; Frost, Thomas; Kavokin, Alexey; Bhattacharya, Pallab

    2017-08-01

    A spin-polarized laser offers inherent control of the output circular polarization. We have investigated the output polarization characteristics of a bulk GaN-based microcavity polariton diode laser at room temperature with electrical injection of spin-polarized electrons via a FeCo /MgO spin injector. Polariton laser operation with a spin-polarized current is characterized by a threshold of ˜69 A / cm2 in the light-current characteristics, a significant reduction of the electroluminescence linewidth and blueshift of the emission peak. A degree of output circular polarization of ˜25 % is recorded under remanent magnetization. A second threshold, due to conventional photon lasing, is observed at an injection of ˜7.2 kA /cm2 . The variation of output circular and linear polarization with spin-polarized injection current has been analyzed with the carrier and exciton rate equations and the Gross-Pitaevskii equations for the condensate and there is good agreement between measured and calculated data.

  2. Room temperature current injection polariton light emitting diode with a hybrid microcavity.

    PubMed

    Lu, Tien-Chang; Chen, Jun-Rong; Lin, Shiang-Chi; Huang, Si-Wei; Wang, Shing-Chung; Yamamoto, Yoshihisa

    2011-07-13

    The strong light-matter interaction within a semiconductor high-Q microcavity has been used to produce half-matter/half-light quasiparticles, exciton-polaritons. The exciton-polaritons have very small effective mass and controllable energy-momentum dispersion relation. These unique properties of polaritons provide the possibility to investigate the fundamental physics including solid-state cavity quantum electrodynamics, and dynamical Bose-Einstein condensates (BECs). Thus far the polariton BEC has been demonstrated using optical excitation. However, from a practical viewpoint, the current injection polariton devices operating at room temperature would be most desirable. Here we report the first realization of a current injection microcavity GaN exciton-polariton light emitting diode (LED) operating under room temperature. The exciton-polariton emission from the LED at photon energy 3.02 eV under strong coupling condition is confirmed through temperature-dependent and angle-resolved electroluminescence spectra.

  3. Demonstration of Tokamak Ohmic Flux Saving by Transient Coaxial Helicity Injection in the National Spherical Torus Experiment

    NASA Astrophysics Data System (ADS)

    Raman, R.; Mueller, D.; Nelson, B. A.; Jarboe, T. R.; Gerhardt, S.; Kugel, H. W.; Leblanc, B.; Maingi, R.; Menard, J.; Ono, M.; Paul, S.; Roquemore, L.; Sabbagh, S.; Soukhanovskii, V.

    2010-03-01

    Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

  4. Graphene as current spreading layer on AlGaInP light emitting diodes

    NASA Astrophysics Data System (ADS)

    Guo, Xia; Feng, Yajie; Liu, Qiaoli; Hu, Anqi; He, Xiaoying; Hu, Zonghai

    2018-05-01

    Due to high transmittance and high mobility, graphene is one of the promising candidates for a current spreading layer, which is crucial to light emitting diode (LED) performance. In this paper, improved AlGaInP LED performance was reported after graphene was applied on the GaP surface. Due to its lowered work function difference than with the GaN material, the electrical properties remain the same without additional voltage bias. The light output power is enhanced by about 40% under the current injection of 5 mA at room temperature, which was confirmed by the light emission profile analysis in this study. Such results indicate that raphene is a promising candidate as a current spreading layer under low current injection.

  5. Overview of MST Results and Plans

    NASA Astrophysics Data System (ADS)

    Sarff, J. S.

    2008-11-01

    Improved confinement with high beta has been established in MST over its full range of plasma current capability using transient inductive current profile control. Both thermal electron and ion confinement are increased, and energetic electrons are observed to 100 keV. The global energy confinement time is 12 ms at high current and high temperature (Te=2 keV, Ti =1 keV), with βtot=10% (only Ohmic heating). Maximum βtot=26% is attained at lower current and temperature with D2 pellet injection, without evidence of hard-beta-limit phenomena. Momentum transport associated with MHD tearing shows the fascinating behavior that the Maxwell and Reynolds turbulent stresses are both large but oppositely directed in sawtooth magnetic relaxation events. Momentum is transported rapidly in these events, presumably through the imbalance in the stresses. Electron temperature fluctuations associated with MHD tearing are measured using a multi-point, multi-pulse Thomson scattering diagnostic. A 5-250 kHz pulse-burst laser is under construction to extend the Thomson capability to high frequency. Lower hybrid and electron Bernstein wave injection are under development to provide more sustained current profile control and heating. X-ray emission from the plasma is observed for both waves at 175 kW injected power. Substantial new experimental capability will be provided by a recently installed programmable power supply for the toroidal field, a new 1 MW, 20 ms neutral beam injection system, and upgraded OFCD system. Supported by U.S. DoE and NSF.

  6. Radiesse: Advanced Techniques and Applications for a Unique and Versatile Implant.

    PubMed

    Eviatar, Joseph; Lo, Christopher; Kirszrot, James

    2015-11-01

    Radiesse is a well-tolerated facial injectable with unique filling and lifting capabilities. Although initially approved for facial volumizing in HIV-related lipodystrophy patients, it quickly gained wide acceptance for aesthetic facial rejuvenation. In the USA, the Food and Drug Administration has approved several new indications for its use. This synopsis presents the experience and injection techniques currently favored by the primary author after many years of use in thousands of patients. The anecdotal practice of an experienced injector is presented along with the current Food and Drug Administration-approved standards of Radiesse injection. Radiesse has many on- and off-label applications that can be thoughtfully incorporated into clinical practice. Its unique chemical composition allows for immediate lifting and filling with long-term collagen stimulation. The product can be reconstituted to increase its versatility and minimize adverse events. Injections can be performed in the supraperiosteal space and the subcutaneous layer and are best administered in small, calculated doses to prevent nodules or vascular occlusion. Various techniques for Radiesse injection in specific areas are discussed in detail. Radiesse is a versatile injectable implant and a valuable tool for short- and long-term cosmetic and reconstructive treatments. In addition to various off-label uses, this injectable is often used in conjunction with botox, other injectables, collagen stimulators and tightening devices. A customized reconstitution of product increases its versatility for natural appearing and long lasting results that are both economical and effective for full facial rejuvenation.

  7. Prevalence of skin problems and leg ulceration in a sample of young injecting drug users.

    PubMed

    Coull, Alison F; Atherton, Iain; Taylor, Avril; Watterson, Andrew E

    2014-08-13

    Drug users suffer harm from the injecting process, and clinical services are reporting increasing numbers presenting with skin-related problems such as abscesses and leg ulcers. Skin breakdown can lead to long-term health problems and increased service costs and is often the first indication of serious systemic ill health. The extent of skin problems in injecting drug users has not previously been quantified empirically, and there is a dearth of robust topical literature. Where skin problems have been reported, this is often without clear definition and generic terms such as 'soft tissue infection' are used which lack specificity. The aim of this study was to identify the range and extent of skin problems including leg ulceration in a sample of injecting drug users. Definitions of skin problems were developed and applied to descriptions from drug users to improve rigour. Data were collected in needle exchanges and methadone clinics across Glasgow, Scotland, from both current and former drug injectors using face-to-face interviews. Two hundred participants were recruited, of which 74% (n = 148) were males and 26% (n = 52) were females. The age range was 21-44 years (mean 35 years). Just under two thirds (64%, n = 127) were currently injecting or had injected within the last 6 months, and 36% (n = 73) had previously injected and had not injected for more than 6 months.Sixty per cent (n = 120) of the sample had experienced a skin problem, and the majority reported more than one problem. Most common were abscesses, lumps, track marks and leg ulcers. Fifteen per cent (n = 30) of all participants reported having had a leg ulcer. This is an original empirical study which demonstrated unique findings of a high prevalence of skin disease (60%) and surprisingly high rates of leg ulceration (15%). Skin disease in injecting drug users is clearly widespread. Leg ulceration in particular is a chronic recurring condition that is costly to treat and has long-term implications for drug users and services caring for current or former injectors long after illicit drug use has ceased.

  8. Evidence of Spin-Injection-Induced Cooper Pair Breaking in Perovskite Ferromagnet-Insulator-Superconductor Heterostructures via Pulsed Current Measurements

    NASA Technical Reports Server (NTRS)

    Yeh, N. C.; Samoilov, A. V.; Veasquez, R. P.; Li, Y.

    1998-01-01

    The effect of spin-polarized currents on the critical current densities of cuprate superconductors is investigated in perovskite ferromagnet-insulator-superconductor heterostructures with a pulsed current technique.

  9. Online Measurement of the Energy Spread of Multi-Turn Beam in the Fermilab Booster at Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, J.; Bhat, C. M.; Hendricks, B. S.

    We have developed a computer program interfaced with the ACNET environment of Fermilab accelerators to measure energy spread of the proton beam from the LINAC at an injection into the Booster. It uses a digitizing oscilloscope and provides users an ability to configure the scope settings for optimal data acquisition from a resistive wall current monitor. When the program is launched, a) a one shot timeline is generated to initiate beam injection into the Booster, b) a gap of about 40 ns is produced in the injected beam using a set of fast kickers, c) collects line charge distribution datamore » from the wall current monitor for the first 200 μs from the injection and d) performs complete data analysis to extract full beam energy spread of the beam. The program also gives the option to store the data for offline analyses. We illustrate a case with an example. We also present results on beam energy spread as a function of beam intensity from recent measurements.« less

  10. Temperature quenching of spontaneous emission in tunnel-injection nanostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talalaev, V. G., E-mail: vadimtalalaev@yandex.com; Novikov, B. V.; Cirlin, G. E.

    2015-11-15

    The spontaneous-emission spectra in the near-IR range (0.8–1.3 μm) from inverted tunnel-injection nanostructures are measured. These structures contain an InAs quantum-dot layer and an InGaAs quantum-well layer, separated by GaAs barrier spacer whose thickness varies in the range 3–9 nm. The temperature dependence of this emission in the range 5–295 K is investigated, both for optical excitation (photoluminescence) and for current injection in p–n junction (electroluminescence). At room temperature, current pumping proves more effective for inverted tunnel-injection nanostructures with a thin barrier (<6 nm), when the apexes of the quantum dots connect with the quantum well by narrow InGaAs strapsmore » (nanobridges). In that case, the quenching of the electroluminescence by heating from 5 to 295 K is slight. The quenching factor S{sub T} of the integrated intensity I is S{sub T} = I{sub 5}/I{sub 295} ≈ 3. The temperature stability of the emission from inverted tunnel-injection nanostructures is discussed on the basis of extended Arrhenius analysis.« less

  11. Frequency division multiplexed radio-over-fiber transmission using an optically injected laser diode

    NASA Astrophysics Data System (ADS)

    Chan, Sze-Chun

    2008-04-01

    Nonlinear dynamics of semiconductor lasers have recently attracted much attention in the area of microwave photonics. By invoking the nonlinear dynamics of an optically injected laser diode, high-speed microwave oscillation can be generated using the period-one oscillation state. The oscillation is harnessed for application as a photonic microwave source in radio-over-fiber (RoF) systems. It is advantageous over conventional direct current modulation because it alleviates the modulation bandwidth limitation and naturally generates single sideband signals. The method is thus applicable to wireless communication systems even when the subcarrier frequency increases to 60 GHz. Because RoF is usually incorporated with standard wireless schemes that involve frequency division multiplexing (FDM), we investigate the performance of the optical injection system under simultaneous current injection of multiple data streams. Frequency mixings and competition for locking among subcarriers result in intermodulation distortion (IMD). The relative weightings of different channels should be optimized to ensure acceptable signal qualities. The results illustrate the feasibility of applying the optical injection system for FDM RoF transmission at high subcarrier frequencies.

  12. SODIUM DITHIONITE INJECTIONS USED FOR CHROMIUM REDUCTION: NEWSLETTER

    EPA Science Inventory

    NEWSLETTER NRMRL-ADA- 02116 Paul*, C.J. "Sodium Dithionite Injections Used for Chromium Reduction." In: Groundwater Currents Newsletter 2002. A field-scale pilot study was conducted in 1999 at the U.S. Coast Guard Support Center in El...

  13. Spectral linewidth of spin-current nano-oscillators driven by nonlocal spin injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demidov, V. E., E-mail: demidov@uni-muenster.de; Divinskiy, B.; Urazhdin, S.

    2015-11-16

    We study experimentally the auto-oscillation characteristics of magnetic nano-oscillators driven by pure spin currents generated by nonlocal spin injection. By combining micro-focus Brillouin light scattering spectroscopy with electronic microwave spectroscopy, we are able to simultaneously perform both the spatial and the high-resolution spectral analyses of auto-oscillations induced by spin current. We find that the devices exhibit a highly coherent dynamics with the spectral linewidth of a few megahertz at room temperature. This narrow linewidth can be achieved over a wide range of operational frequencies, demonstrating a significant potential of nonlocal oscillators for applications.

  14. Development of simplified external control techniques for broad area semiconductor lasers

    NASA Technical Reports Server (NTRS)

    Davis, Christopher C.

    1993-01-01

    The goal of this project was to injection lock a 500 mW broad area laser diode (BAL) with a single mode low power laser diode with injection beam delivery through a single mode optical fiber (SMF). This task was completed successfully with the following significant accomplishments: (1) injection locking of a BAL through a single-mode fiber using a master oscillator and integrated miniature optics; (2) generation of a single-lobed, high-power far-field pattern from the injection-locked BAL that steers with drive current; and (3) a comprehensive theoretical analysis of a model that describes the observed behavior of the injection locked oscillator.

  15. Monitoring method and apparatus using high-frequency carrier

    DOEpatents

    Haynes, H.D.

    1996-04-30

    A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device. 6 figs.

  16. On the Hole Injection for III-Nitride Based Deep Ultraviolet Light-Emitting Diodes.

    PubMed

    Li, Luping; Zhang, Yonghui; Xu, Shu; Bi, Wengang; Zhang, Zi-Hui; Kuo, Hao-Chung

    2017-10-24

    The hole injection is one of the bottlenecks that strongly hinder the quantum efficiency and the optical power for deep ultraviolet light-emitting diodes (DUV LEDs) with the emission wavelength smaller than 360 nm. The hole injection efficiency for DUV LEDs is co-affected by the p-type ohmic contact, the p-type hole injection layer, the p-type electron blocking layer and the multiple quantum wells. In this report, we review a large diversity of advances that are currently adopted to increase the hole injection efficiency for DUV LEDs. Moreover, by disclosing the underlying device physics, the design strategies that we can follow have also been suggested to improve the hole injection for DUV LEDs.

  17. On the Hole Injection for III-Nitride Based Deep Ultraviolet Light-Emitting Diodes

    PubMed Central

    Li, Luping; Zhang, Yonghui; Kuo, Hao-Chung

    2017-01-01

    The hole injection is one of the bottlenecks that strongly hinder the quantum efficiency and the optical power for deep ultraviolet light-emitting diodes (DUV LEDs) with the emission wavelength smaller than 360 nm. The hole injection efficiency for DUV LEDs is co-affected by the p-type ohmic contact, the p-type hole injection layer, the p-type electron blocking layer and the multiple quantum wells. In this report, we review a large diversity of advances that are currently adopted to increase the hole injection efficiency for DUV LEDs. Moreover, by disclosing the underlying device physics, the design strategies that we can follow have also been suggested to improve the hole injection for DUV LEDs. PMID:29073738

  18. On neutral-beam injection counter to the plasma current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helander, P.; Akers, R.J.; Eriksson, L.-G.

    2005-11-15

    It is well known that when neutral beams inject ions into trapped orbits in a tokamak, the transfer of momentum between the beam and the plasma occurs through the torque exerted by a radial return current. It is shown that this implies that the angular momentum transferred to the plasma can be larger than the angular momentum of the beam, if the injection is in the opposite direction to the plasma current and the beam ions suffer orbit losses. On the Mega-Ampere Spherical Tokamak (MAST) [R. J. Akers, J. W. Ahn, G. Y. Antar, L. C. Appel, D. Applegate, C.more » Brickley et al., Plasma Phys. Controlled Fusion 45, A175 (2003)], this results in up to 30% larger momentum deposition with counterinjection than with co-injection, with substantially increased plasma rotation as a result. It is also shown that heating of the plasma (most probably of the ions) can occur even when the beam ions are lost before they have had time to slow down in the plasma. This is the dominant heating mechanism in the outer 40% of the MAST plasma during counterinjection.« less

  19. Non-Solenoidal Startup Research Directions on the Pegasus Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Fonck, R. J.; Bongard, M. W.; Lewicki, B. T.; Reusch, J. A.; Winz, G. R.

    2017-10-01

    The Pegasus research program has been focused on developing a physical understanding and predictive models for non-solenoidal tokamak plasma startup using Local Helicity Injection (LHI). LHI employs strong localized electron currents injected along magnetic field lines in the plasma edge that relax through magnetic turbulence to form a tokamak-like plasma. Pending approval, the Pegasus program will address a broader, more comprehensive examination of non-solenoidal tokamak startup techniques. New capabilities may include: increasing the toroidal field to 0.6 T to support critical scaling tests to near-NSTX-U field levels; deploying internal plasma diagnostics; installing a coaxial helicity injection (CHI) capability in the upper divertor region; and deploying a modest (200-400 kW) electron cyclotron RF capability. These efforts will address scaling of relevant physics to higher BT, separate and comparative studies of helicity injection techniques, efficiency of handoff to consequent current sustainment techniques, and the use of ECH to synergistically improve the target plasma for consequent bootstrap and neutral beam current drive sustainment. This has an ultimate goal of validating techniques to produce a 1 MA target plasma in NSTX-U and beyond. Work supported by US DOE Grant DE-FG02-96ER54375.

  20. Integrated injection-locked semiconductor diode laser

    DOEpatents

    Hadley, G. Ronald; Hohimer, John P.; Owyoung, Adelbert

    1991-01-01

    A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet.

  1. Coupling between Transport and Injection Properties of Pentacene Field-Effect Transistors with Different Morphologies

    NASA Astrophysics Data System (ADS)

    Lee, Keanchuan; Weis, Martin; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa

    2013-08-01

    We investigated the injection and transport properties of pentacene organic field-effect transistors (OFETs) with inclined and lamellar pentacene grains at various mutual ratios. Although the threshold voltage was conserved and no additional trapping on grain boundaries was suggested from the current-voltage measurements, the contact resistance and mobility increased linearly with the lamellar phase content. We showed that a model based on the coupling between both transport and injection properties via a space charge field caused by injected and trapped carriers accounts for these results.

  2. Large-volume flux closure during plasmoid-mediated reconnection in coaxial helicity injection

    DOE PAGES

    Ebrahimi, F.; Raman, R.

    2016-03-23

    A large-volume flux closure during transient coaxial helicity injection (CHI) in NSTX-U is demonstrated through resistive magnetohydrodynamics (MHD) simulations. Several major improvements, including the improved positioning of the divertor poloidal field coils, are projected to improve the CHI start-up phase in NSTX-U. Simulations in the NSTX-U configuration with constant in time coil currents show that with strong flux shaping the injected open field lines (injector flux) rapidly reconnect and form large volume of closed flux surfaces. This is achieved by driving parallel current in the injector flux coil and oppositely directed currents in the flux shaping coils to form amore » narrow injector flux footprint and push the injector flux into the vessel. As the helicity and plasma are injected into the device, the oppositely directed field lines in the injector region are forced to reconnect through a local Sweet-Parker type reconnection, or to spontaneously reconnect when the elongated current sheet becomes MHD unstable to form plasmoids. In these simulations for the first time, it is found that the closed flux is over 70% of the initial injector flux used to initiate the discharge. Furthermore, these results could work well for the application of transient CHI in devices that employ super conducting coils to generate and sustain the plasma equilibrium.« less

  3. "The first shot": the context of first injection of illicit drugs, ongoing injecting practices, and hepatitis C infection in Rio de Janeiro, Brazil.

    PubMed

    Oliveira, Maria de Lourdes Aguiar; Hacker, Mariana A; Oliveira, Sabrina Alberti Nóbrega de; Telles, Paulo Roberto; O, Kycia Maria Rodrigues do; Yoshida, Clara Fumiko Tachibana; Bastos, Francisco I

    2006-04-01

    The context of first drug injection and its association with ongoing injecting practices and HCV (hepatitis C virus) infection were investigated. Injection drug users (IDUs) (N = 606) were recruited in "drug scenes" (public places, bars) in Rio de Janeiro, Brazil, interviewed, and tested for HCV. Sharing of needles/syringes was more prevalent at the first injection (51.3%) than at the baseline interview (36.8%). Those who shared syringes/needles at first injection were more likely to be currently engaged in direct/indirect sharing practices. Among young injectors (< 30 years), those reporting sharing of needles/ syringes at the first injection were about four times more likely to have been infected by HCV. Hepatitis C virus prevalence among active IDUs (n = 272) was 11%. Prison history and longer duration of drug injection were identified as independent predictors of HCV infection. To effectively curb HCV transmission among IDUs and minimize harms associated with risk behaviors, preventive strategies should target individuals initiating drug injection beginning with their very first injection and discourage the transition from non-injecting use to the self-injection of illicit drugs.

  4. MERCURY CONTROL IN MUNICIPAL WASTE COMBUSTORS AND COAL-FIRED UTILITIES

    EPA Science Inventory

    Control of mercury (Hg) emissions from municipal waste combustors (MWCs) and coal-fired utilities has attracted attention due to current and potential regulations. Among several techniques evaluated for Hg control, dry sorbent injection (primarily injection of activated carbon) h...

  5. Crack Cocaine Injection Practices and HIV Risk: Findings From New York and Bridgeport

    PubMed Central

    Lankenau, Stephen E.; Clatts, Michael C.; Goldsamt, Lloyd A.; Welle, Dorinda L.

    2007-01-01

    This article examines the behavioral practices and health risks associated with preparing crack cocaine for injection. Using an ethno-epidemiological approach, injection drug users (n=38) were recruited between 1999 and 2000 from public settings in New York City and Bridgeport, Connecticut and responded to a semistructured interview focusing on crack injection initiation and their most recent crack injection. Study findings indicate that methods of preparing crack for injection were impacted by a transforming agent, heat applied to the “cooker,” heroin use, age of the injector, and geographic location of the injector. The findings suggest that crack injectors use a variety of methods to prepare crack, which may carry different risks for the transmission of bloodborne pathogens. In particular, crack injection may be an important factor in the current HIV epidemic. PMID:18079990

  6. Induced seismicity provides insight into why earthquake ruptures stop

    PubMed Central

    Galis, Martin; Ampuero, Jean Paul; Mai, P. Martin; Cappa, Frédéric

    2017-01-01

    Injection-induced earthquakes pose a serious seismic hazard but also offer an opportunity to gain insight into earthquake physics. Currently used models relating the maximum magnitude of injection-induced earthquakes to injection parameters do not incorporate rupture physics. We develop theoretical estimates, validated by simulations, of the size of ruptures induced by localized pore-pressure perturbations and propagating on prestressed faults. Our model accounts for ruptures growing beyond the perturbed area and distinguishes self-arrested from runaway ruptures. We develop a theoretical scaling relation between the largest magnitude of self-arrested earthquakes and the injected volume and find it consistent with observed maximum magnitudes of injection-induced earthquakes over a broad range of injected volumes, suggesting that, although runaway ruptures are possible, most injection-induced events so far have been self-arrested ruptures. PMID:29291250

  7. Disposal of liquid wastes by injection underground--Neither myth nor millennium

    USGS Publications Warehouse

    Piper, Arthur M.

    1969-01-01

    Injecting liquid wastes deep underground is an attractive but not necessarily practical means for disposing of them. For decades, impressive volumes of unwanted oil-field brine have been injected, currently about 10,000 acre-feet yearly. Recently, liquid industrial wastes are being injected in ever-increasing quantity. Dimensions of industrial injection wells range widely but the approximate medians are: depth, 2,660 feet; thickness of injection zone, 185 feet; injection rate, 135 gallons per minute; wellhead injection pressure, 185 pounds per square inch. Effects of deep injection are complex and not all are understood clearly. In a responsible society, injection cannot be allowed to put wastes out of mind. Injection is no more than storage--for all time in the case of the most intractable wastes--in underground space of which little is attainable in some areas and which is exhaustible in most areas. Liquid wastes range widely in character and concentration-some are incompatible one with another or with materials of the prospective injection zone; some which are reactive or chemically unstable would require pretreatment or could not be injected. Standards by which to categorize the wastes are urgently desirable. To the end that injection may be planned effectively and administered in orderly fashion, there is proposed an immediate and comprehensive canvass of all the United States to outline injection provinces and zones according to their capacities to accept waste. Much of the information needed to this end is at hand. Such a canvass would consider (1) natural zone, of groundwater circulation, from rapid to stagnant, (2) regional hydrodynamics, (3) safe injection pressures, and (4) geochemical aspects. In regard to safe pressure, definitive criteria would be sought by which to avoid recurrence of earthquake swarms such as seem to have been triggered by injection at the Rocky Mountain Arsenal well near Denver, Colo. Three of the 50 States--Missouri, .Ohio, and Texas-have statutes specifically to regulate injection of industrial wastes. Other States impose widely diverse constraints under unlike administrative authorities. Few, if any, State agencies currently have the staff skills, centralized authority, and financial resources to assure rights of the general public to be spared harm from, and to reap the benefit of accrued experience with, deep injection. Some new, fully competent institutional arrangement appears to be essential, under a unified policy. As required, such an institution might have en echelon components, respectively having nationwide, single State or major province, subprovince, or local jurisdiction.

  8. Utilizing Schottky barriers to suppress short-channel effects in organic transistors

    NASA Astrophysics Data System (ADS)

    Fernández, Anton F.; Zojer, Karin

    2017-10-01

    Transistors with short channel lengths exhibit profound deviations from the ideally expected behavior. One of the undesired short-channel effects is an enlarged OFF current that is associated with a premature turn on of the transistor. We present an efficient approach to suppress the OFF current, defined as the current at zero gate source bias, in short-channel organic transistors. We employ two-dimensional device simulations based on the drift-diffusion model to demonstrate that intentionally incorporating a Schottky barrier for injection enhances the ON-OFF ratio in both staggered and coplanar transistor architectures. The Schottky barrier is identified to directly counteract the origin of enlarged OFF currents: Short channels promote a drain-induced barrier lowering. The latter permits unhindered injection of charges even at reverse gate-source bias. An additional Schottky barrier hampers injection for such points of operations. We explain how it is possible to find the Schottky barrier of the smallest height necessary to exactly compensate for the premature turn on. This approach offers a substantial enhancement of the ON-OFF ratio. We show that this roots in the fact that such optimal barrier heights offer an excellent compromise between an OFF current diminished by orders of magnitude and an only slightly reduced ON current.

  9. Efficacy of basal soil injection at different water volumes and landscape settings for Asian longhorn beetle control

    Treesearch

    Phillip A. Lewis

    2007-01-01

    The Asian longhorn beetle eradication program currently treats at-risk trees by soil injection with a high volume solution of pesticide placed in concentric rings expanding out from the trunk to the dripline of the tree. Using this method in wooded habitats has previously resulted in no detectable residue in treated trees. Basal soil injection (BSI) uses a high...

  10. Fourteen babies born after round spermatid injection into human oocytes

    PubMed Central

    Tanaka, Atsushi; Nagayoshi, Motoi; Takemoto, Youichi; Tanaka, Izumi; Kusunoki, Hiroshi; Watanabe, Seiji; Kuroda, Keiji; Takeda, Satoru; Ito, Masahiko; Yanagimachi, Ryuzo

    2015-01-01

    During the human in vitro fertilization procedure in the assisted reproductive technology, intracytoplasmic sperm injection is routinely used to inject a spermatozoon or a less mature elongating spermatid into the oocyte. In some infertile men, round spermatids (haploid male germ cells that have completed meiosis) are the most mature cells visible during testicular biopsy. The microsurgical injection of a round spermatid into an oocyte as a substitute is commonly referred to as round spermatid injection (ROSI). Currently, human ROSI is considered a very inefficient procedure and of no clinical value. Herein, we report the birth and development of 14 children born to 12 women following ROSI of 734 oocytes previously activated by an electric current. The round spermatids came from men who had been diagnosed as not having spermatozoa or elongated spermatids by andrologists at other hospitals after a first Micro-TESE. A key to our success was our ability to identify round spermatids accurately before oocyte injection. As of today, all children born after ROSI in our clinic are without any unusual physical, mental, or epigenetic problems. Thus, for men whose germ cells are unable to develop beyond the round spermatid stage, ROSI can, as a last resort, enable them to have their own genetic offspring. PMID:26575628

  11. Fourteen babies born after round spermatid injection into human oocytes.

    PubMed

    Tanaka, Atsushi; Nagayoshi, Motoi; Takemoto, Youichi; Tanaka, Izumi; Kusunoki, Hiroshi; Watanabe, Seiji; Kuroda, Keiji; Takeda, Satoru; Ito, Masahiko; Yanagimachi, Ryuzo

    2015-11-24

    During the human in vitro fertilization procedure in the assisted reproductive technology, intracytoplasmic sperm injection is routinely used to inject a spermatozoon or a less mature elongating spermatid into the oocyte. In some infertile men, round spermatids (haploid male germ cells that have completed meiosis) are the most mature cells visible during testicular biopsy. The microsurgical injection of a round spermatid into an oocyte as a substitute is commonly referred to as round spermatid injection (ROSI). Currently, human ROSI is considered a very inefficient procedure and of no clinical value. Herein, we report the birth and development of 14 children born to 12 women following ROSI of 734 oocytes previously activated by an electric current. The round spermatids came from men who had been diagnosed as not having spermatozoa or elongated spermatids by andrologists at other hospitals after a first Micro-TESE. A key to our success was our ability to identify round spermatids accurately before oocyte injection. As of today, all children born after ROSI in our clinic are without any unusual physical, mental, or epigenetic problems. Thus, for men whose germ cells are unable to develop beyond the round spermatid stage, ROSI can, as a last resort, enable them to have their own genetic offspring.

  12. Injectable silk foams for the treatment of cervical insufficiency

    NASA Astrophysics Data System (ADS)

    Fournier, Eric P.

    Preterm birth is the leading cause of neonatal mortality, resulting in over 4,000 deaths each year. A significant risk factor for preterm birth is cervical insufficiency, the weakening and subsequent deformation of cervical tissue. Cervical insufficiency is both detectable and treatable but current treatments are lacking. The most common approach requires multiple invasive procedures. This work investigates the injection of silk foams, a minimally-invasive method for supporting cervical tissue. Silk offers many advantages for use as a biomaterial including strength, versatility, and biocompatibility. Injectable silk foams will minimize patient discomfort while also providing more targeted and personalized treatment. A battery of mechanical testing was undertaken to determine silk foam response under physiologically relevant loading and environmental conditions. Mechanical testing was paired with analysis of foam morphology and structure that illustrated the effects of injection on pore geometry and size. Biological response to silk foams was evaluated using an in vitro degradation study and subcutaneous in vivo implantation in a mouse model. Results showed that foams exceeded the mechanical requirements for stiffening cervical tissue, although the current injection process limits foam size. Injection was shown to cause measurable but localized foam deformation. This work indicates that silk foams are a feasible treatment option for cervical insufficiency but challenges remain with foam delivery.

  13. NON-NEUTRALIZED ELECTRIC CURRENT PATTERNS IN SOLAR ACTIVE REGIONS: ORIGIN OF THE SHEAR-GENERATING LORENTZ FORCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Georgoulis, Manolis K.; Titov, Viacheslav S.; Mikic, Zoran

    Using solar vector magnetograms of the highest available spatial resolution and signal-to-noise ratio, we perform a detailed study of electric current patterns in two solar active regions (ARs): a flaring/eruptive and a flare-quiet one. We aim to determine whether ARs inject non-neutralized (net) electric currents in the solar atmosphere, responding to a debate initiated nearly two decades ago that remains inconclusive. We find that well-formed, intense magnetic polarity inversion lines (PILs) within ARs are the only photospheric magnetic structures that support significant net current. More intense PILs seem to imply stronger non-neutralized current patterns per polarity. This finding revises previousmore » works that claim frequent injections of intense non-neutralized currents by most ARs appearing in the solar disk but also works that altogether rule out injection of non-neutralized currents. In agreement with previous studies, we also find that magnetically isolated ARs remain globally current-balanced. In addition, we confirm and quantify the preference of a given magnetic polarity to follow a given sense of electric currents, indicating a dominant sense of twist in ARs. This coherence effect is more pronounced in more compact ARs with stronger PILs and must be of sub-photospheric origin. Our results yield a natural explanation of the Lorentz force, invariably generating velocity and magnetic shear along strong PILs, thus setting a physical context for the observed pre-eruption evolution in solar ARs.« less

  14. First Plasma Results from the HIT-SI Spheromak

    NASA Astrophysics Data System (ADS)

    Sieck, P. E.; Hamp, W. T.; Izzo, V. A.; Jarboe, T. R.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.

    2003-10-01

    HIT-SI is the newest device in the Helicity Injected Torus (HIT) program. HIT-SI is a ``bow tie'' spheromak formed and sustained by Steady Inductive Helicity Injection (SIHI) current drive. SIHI injects helicity at a nearly constant rate with no open field lines intersecting the boundary. (T. R. Jarboe, Fusion Technology 36) (1), p. 85, 1999 HIT-SI has been designed with a bow tie geometry to achieve stable high-β (>10%) spheromak equilibria. (U. Shumlak and T. R. Jarboe, Phys. Plasmas 7) (7), p. 2959, 2000 Diagnostics currently include surface magnetic probes and flux loops, visible light imaging, H-alpha line radiation monitors, voltage measurements across insulating breaks, injector current Rogowski coils, and injector flux loops. HIT-SI is currently operating in parallel with experiments on HIT-II. At the conclusion of HIT-II operations, HIT-SI will inherit a multi-point Thomson Scattering system, a scanning two-chord FIR interferometer, and other advanced diagnostics, as well as more power supplies to extend the discharge duration. Results are presented which characterize injector operation and possible evidence for spheromak formation.

  15. Analysis of the abnormal voltage-current behaviors on localized carriers of InGaN/GaN multiple quantum well from electron blocking layer

    NASA Astrophysics Data System (ADS)

    Nam, Giwoong; Kim, Byunggu; Leem, Jae-Young; Lee, Dong-Yul; Kim, Jong Su; Kim, Jin Soo

    2013-11-01

    The effect of an electron blocking layer (EBL) on the V — I curves for GaN/InGaN multiple quantum wells is investigated. For the first time, we found that the curves intersected at 3.012 V, and we investigated the reason for the intersection. The forward voltage in LEDs with a p-AlGaN EBL is larger than it is without the p-AlGaN EBL at low injection currents because the Mg-doping efficiency for the p-GaN layer is higher than that for the p-AlGaN layer. However, the forward voltage in LEDs with a p-AlGaN EBL is smaller than it is without the p-AlGaN EBL at high injection currents because the carriers overflow from the active layer when the injection current increases in LEDs without a p-AlGaN EBL, in case of LEDs with a p-AlGaN EBL, the carriers are blocked by the EBL.

  16. Hole injection and dielectric breakdown in 6H-SiC and 4H-SiC metal-oxide-semiconductor structures during substrate electron injection via Fowler-Nordheim tunneling

    NASA Astrophysics Data System (ADS)

    Samanta, Piyas; Mandal, Krishna C.

    2015-12-01

    Hole injection into silicon dioxide (SiO2) films (8-40 nm thick) is investigated for the first time during substrate electron injection via Fowler-Nordheim (FN) tunneling in n-type 4H- and 6H-SiC (silicon carbide) based metal-oxide-semiconductor (MOS) structures at a wide range of temperatures (T) between 298 and 598 K and oxide electric fields Eox from 6 to 10 MV/cm. Holes are generated in heavily doped n-type polycrystalline silicon (n+ -polySi) gate serving as the anode as well as in the bulk silicon dioxide (SiO2) film via hot-electron initiated band-to-band ionization (BTBI). In absence of oxide trapped charges, it is shown that at a given temperature, the hole injection rates from either of the above two mechanisms are higher in n-4H-SiC MOS devices than those in n-6H-SiC MOS structures when compared at a given Eox and SiO2 thickness (tox). On the other hand, relative to n-4H-SiC devices, n-6H-SiC structures exhibit higher hole injection rates for a given tox during substrate electron injection at a given FN current density je,FN throughout the temperature range studied here. These two observations clearly reveal that the substrate material (n-6H-SiC and n-4H-SiC) dependencies on time-to-breakdown (tBD) or injected charge (electron) to breakdown (QBD) of the SiO2 film depend on the mode of FN injections (constant field/voltage and current) from the substrate which is further verified from the rigorous device simulation as well.

  17. Subauroral polarization stream on the outer boundary of the ring current during an energetic ion injection event

    NASA Astrophysics Data System (ADS)

    Yuan, Zhigang; Qiao, Zheng; Li, Haimeng; Huang, Shiyong; Wang, Dedong; Yu, Xiongdong; Yu, Tao

    2017-04-01

    Subauroral polarization stream (SAPS) electric field can play an important role in the coupling between the inner magnetosphere and ionosphere; however, the production mechanism of SAPS has not been yet solved. During an energetic ion injection event on 26 March 2004, at latitudes lower than the equatorward boundaries of precipitating plasma sheet electrons and ions, the Defense Meteorological Satellite Program (DMSP) F13 satellite simultaneously observed a strong SAPS with the peak velocity of 1294 m/s and downward flowing field-aligned currents (FACs). Conjugate observations of DMSP F13 and NOAA 15 satellites have shown that FACs flowing into the ionosphere just lie in the outer boundary of the ring current (RC). The downward flowing FACs were observed in a region of positive latitudinal gradients of the ion energy density, implying that the downward flowing FACs are more likely linked to the azimuthal gradient than the radial gradient of the RC ion pressure. Our result demonstrates that RC ion pressure gradients on the outer boundary of the RC in the evening sector during energetic ion injection events can lead to downward flowing FACs so as to cause strong SAPS in condition of low ionospheric conductivities.Plain Language SummaryThis paper provides a good case that the SAPS and FAC occurred in the outer boundary of the ring current during an energetic ion injection event. Our result demonstrates that RC ion pressure gradients on the outer boundary of the RC in the evening sector during energetic ion injection events can lead to downward flowing FACs so as to cause strong SAPS in condition of low ionospheric conductivities.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016APS..DPPDI2004E','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016APS..DPPDI2004E"><span>Plasmoids formation in a laboratory and large-volume flux closure during simulations of Coaxial Helicity Injection in NSTX-U</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Ebrahimi, Fatima</p> <p>2016-10-01</p> <p>In NSTX-U, transient Coaxial Helicity Injection (CHI) is the primary method for current generation without reliance on the solenoid. A CHI discharge is generated by driving current along open field lines (the injector flux) that connect the inner and outer divertor plates on NSTX/NSTX-U, and has generated over 200 kA of toroidal current on closed flux surfaces in NSTX. Extrapolation of the concept to larger devices requires an improved understanding of the physics of flux closure and the governing parameters that maximizes the fraction of injected flux that is converted to useful closed flux. Here, through comprehensive resistive MHD NIMROD simulations conducted for the NSTX and NSTX-U geometries, two new major findings will be reported. First, formation of an elongated Sweet-Parker current sheet and a transition to plasmoid instability has for the first time been demonstrated by realistic global simulations. This is the first observation of plasmoid instability in a laboratory device configuration predicted by realistic MHD simulations and then supported by experimental camera images from NSTX. Second, simulations have now, for the first time, been able to show large fraction conversion of injected open flux to closed flux in the NSTX-U geometry. Consistent with the experiment, simulations also show that reconnection could occur at every stage of the helicity injection phase. The influence of 3D effects, and the parameter range that supports these important new findings is now being studied to understand the impact of toroidal magnetic field and the electron temperature, both of which are projected to increase in larger ST devices. Work supported by DOE DE-SC0010565.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=2278642','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=2278642"><span>Dendritic mechanisms underlying the coupling of the dendritic with the axonal action potential initiation zone of adult rat layer 5 pyramidal neurons</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Larkum, M E; Zhu, J J; Sakmann, B</p> <p>2001-01-01</p> <p>Double, triple and quadruple whole-cell voltage recordings were made simultaneously from different parts of the apical dendritic arbor and the soma of adult layer 5 (L5) pyramidal neurons. We investigated the membrane mechanisms that support the conduction of dendritic action potentials (APs) between the dendritic and axonal AP initiation zones and their influence on the subsequent AP pattern. The duration of the current injection to the distal dendritic initiation zone controlled the degree of coupling with the axonal initiation zone and the AP pattern. Two components of the distally evoked regenerative potential were pharmacologically distinguished: a rapidly rising peak potential that was TTX sensitive and a slowly rising plateau-like potential that was Cd2+ and Ni2+ sensitive and present only with longer-duration current injection. The amplitude of the faster forward-propagating Na+-dependent component and the amplitude of the back-propagating AP fell into two classes (more distinctly in the forward-propagating case). Current injection into the dendrite altered propagation in both directions. Somatic current injections that elicited single Na+ APs evoked bursts of Na+ APs when current was injected simultaneously into the proximal apical dendrite. The mechanism did not depend on dendritic Na+–Ca2+ APs. A three-compartment model of a L5 pyramidal neuron is proposed. It comprises the distal dendritic and axonal AP initiation zones and the proximal apical dendrite. Each compartment contributes to the initiation and to the pattern of AP discharge in a distinct manner. Input to the three main dendritic arbors (tuft dendrites, apical oblique dendrites and basal dendrites) has a dominant influence on only one of these compartments. Thus, the AP pattern of L5 pyramids reflects the laminar distribution of synaptic activity in a cortical column. PMID:11389204</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22314672-measurement-axial-injection-displacement-trim-coil-current-unbalance','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22314672-measurement-axial-injection-displacement-trim-coil-current-unbalance"><span>Measurement of axial injection displacement with trim coil current unbalance</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Covo, Michel Kireeff, E-mail: mkireeffcovo@lbl.gov</p> <p></p> <p>The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li class="active"><span>22</span></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_22 --> <div id="page_23" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="441"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22412577-critical-current-linewidth-reduction-spin-torque-nano-oscillators-delayed-self-injection','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22412577-critical-current-linewidth-reduction-spin-torque-nano-oscillators-delayed-self-injection"><span>Critical current and linewidth reduction in spin-torque nano-oscillators by delayed self-injection</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Khalsa, Guru, E-mail: guru.khalsa@nist.gov; Stiles, M. D.; Grollier, J.</p> <p>2015-06-15</p> <p>Based on theoretical models, the dynamics of spin-torque nano-oscillators can be substantially modified by re-injecting the emitted signal to the input of the oscillator after some delay. Numerical simulations for vortex magnetic tunnel junctions show that with reasonable parameters this approach can decrease critical currents as much as 25% and linewidths by a factor of 4. Analytical calculations, which agree well with simulations, demonstrate that these results can be generalized to any kind of spin-torque oscillator.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=19810033343&hterms=high+current+electron+beam&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D80%26Ntt%3Dhigh%2Bcurrent%2Belectron%2Bbeam','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=19810033343&hterms=high+current+electron+beam&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D80%26Ntt%3Dhigh%2Bcurrent%2Belectron%2Bbeam"><span>Observations of waves artificially stimulated by an electron beam inside a region with auroral precipitation</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Grandal, B.; Troim, J.; Maehlum, B.; Holtet, J. A.; Pran, B.</p> <p>1980-01-01</p> <p>Observations of waves stimulated by artificial injection inside an auroral arc by an electron accelerator mounted on the POLAR 5 sounding rocket are presented. The accelerator produced a pulsed electron beam with currents up to 130 mA and energies up to 10 keV; emissions after the end of beam injection were generated by perturbations in the ambient plasma near the accelerator during beam injection. These emissions were independent of the electron beam direction along the geomagnetic field. The high frequency emission observed after beam injection correlated with the passage through an auroral arc; the low frequency emissions after beam injection were concentrated in two bands below the lower hybrid frequency.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27370428','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27370428"><span>Active stabilization of a diode laser injection lock.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep</p> <p>2016-06-01</p> <p>We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25899076','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25899076"><span>Long-acting injectable hormonal dosage forms for contraception.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wu, Linfeng; Janagam, Dileep R; Mandrell, Timothy D; Johnson, James R; Lowe, Tao L</p> <p>2015-07-01</p> <p>Although great efforts have been made to develop long-acting injectable hormonal contraceptives for more than four decades, few long-acting injectable contraceptives have reached the pharmaceutical market or even entered clinical trials. On the other hand, in clinical practice there is an urgent need for injectable long-acting reversible contraceptives which can provide contraceptive protection for more than 3 months after one single injection. Availability of such products will offer great flexibility to women and resolve certain continuation issues currently occurring in clinics. Herein, we reviewed the strategies exploited in the past to develop injectable hormonal contraceptive dosages including drug microcrystal suspensions, drug-loaded microsphere suspensions and in situ forming depot systems for long-term contraception and discussed the potential solutions for remaining issues met in the previous development.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.dtic.mil/docs/citations/ADA012237','DTIC-ST'); return false;" href="http://www.dtic.mil/docs/citations/ADA012237"><span>Rotating Band Torques and Stresses on AMCAWS 30mm Copper Banded Projectiles</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.dtic.mil/">DTIC Science & Technology</a></p> <p></p> <p>1975-05-01</p> <p>e00 CA,.L A~iSC-!.0,U.0,.IbnSHEAk bTRLSS ON MOATING ’. ANL ) (PSI), uvj0ub0, (0’jCALL AXIS(-.bvC.UjirrSLAkINO3 SUNESS UN RuTATING dAND (Pb!)v 00000-170 L...SHOULC Cffi)kSPO.,uv TO ITS AiUSCISSA VALI.Ev DCI)o FOR I bo0003o0 C FR~OM 1 TO 44. 00008310 C LC’JDE IF LCCO..0* THE MINIMUM$ ANL ’MAX!P.UMS OF TrIE SET...6613.60 4e) 1(0.20 v. ol3 114 5.14 11011 1 "? /9bj1. fp, U.0’t 6630.34. 221,54.11 0 01,14". b.po1 MlIl ?6-o JQ11oVb~s 6034 .Sb 221 b.1I I 31.60,4h9 ’.𔄀</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27998131','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27998131"><span>InGaN-Based Light-Emitting Diodes Grown on a Micro/Nanoscale Hybrid Patterned Sapphire Substrate.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ke, Wen-Cheng; Lee, Fang-Wei; Chiang, Chih-Yung; Liang, Zhong-Yi; Chen, Wei-Kuo; Seong, Tae-Yeon</p> <p>2016-12-21</p> <p>A hybrid patterned sapphire substrate (hybrid-PSS) was prepared using an anodic aluminum oxide etching mask to transfer nanopatterns onto a conventional patterned sapphire substrate with microscale patterns (bare-PSS). The threading dislocation (TD) suppression of light-emitting diodes (LEDs) grown on a hybrid-PSS (HP-LED) exhibits a smaller reverse leakage current compared with that of LEDs grown on a bare-PSS (BP-LED). The strain-free GaN buffer layer and fully strained InGaN active layer were evidenced by cross-sectional Raman spectra and reciprocal space mapping of the X-ray diffraction intensity for both samples. The calculated piezoelectric fields for both samples are close, implying that the quantum-confined Stark effect was not a dominant mechanism influencing the electroluminescence (EL) peak wavelength under a high injection current. The bandgap shrinkage effect of the InGaN well layer was considered to explain the large red-shifted EL peak wavelength under high injection currents. The estimated LED chip temperatures rise from room temperature to 150 °C and 75 °C for BP-LED and HP-LED, respectively, at a 600-mA injection current. This smaller temperature rise of the LED chip is attributed to the increased contact area between the sapphire and the LED structural layer because of the embedded nanopattern. Although the chip generates more heat at high injection currents, the accumulated heat can be removed to outside the chip effectively. The high diffuse reflection (DR) rate of hybrid-PSS increases the escape probability of photons, resulting in an increase in the viewing angle of the LEDs from 130° to 145°. The efficiency droop was reduced from 46% to 35%, effects which can be attributed to the elimination of TDs and strain relaxation by embedded nanopatterns. In addition, the light output power of HP-LED at 360-mA injection currents exhibits a ∼ 22.3% enhancement, demonstrating that hybrid-PSSs are beneficial to apply in high-power LEDs.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21369003','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21369003"><span>GaInAsP/InP lateral-current-injection distributed feedback laser with a-Si surface grating.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Shindo, Takahiko; Okumura, Tadashi; Ito, Hitomi; Koguchi, Takayuki; Takahashi, Daisuke; Atsumi, Yuki; Kang, Joonhyun; Osabe, Ryo; Amemiya, Tomohiro; Nishiyama, Nobuhiko; Arai, Shigehisa</p> <p>2011-01-31</p> <p>We fabricated a novel lateral-current-injection-type distributed feedback (DFB) laser with amorphous-Si (a-Si) surface grating as a step to realize membrane lasers. This laser consists of a thin GaInAsP core layer grown on a semi-insulating InP substrate and a 30-nm-thick a-Si surface layer for DFB grating. Under a room-temperature continuous-wave condition, a low threshold current of 7.0 mA and high efficiency of 43% from the front facet were obtained for a 2.0-μm stripe width and 300-μm cavity length. A small-signal modulation bandwidth of 4.8 GHz was obtained at a bias current of 30 mA.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/864835','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/864835"><span>System and method for generating current by selective electron heating</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Fisch, Nathaniel J.; Boozer, Allen H.</p> <p>1984-01-01</p> <p>A system for the generation of toroidal current in a plasma which is prepared in a toroidal magnetic field. The system utilizes the injection of high-frequency waves into the plasma by means of waveguides. The wave frequency and polarization are chosen such that when the waveguides are tilted in a predetermined fashion, the wave energy is absorbed preferentially by electrons traveling in one toroidal direction. The absorption of energy in this manner produces a toroidal electric current even when the injected waves themselves do not have substantial toroidal momentum. This current can be continuously maintained at modest cost in power and may be used to confine the plasma. The system can operate efficiently on fusion grade tokamak plasmas.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018AIPC.1953e0066K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018AIPC.1953e0066K"><span>Study of charge transport in composite blend of P3HT and PCBM</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Kumar, Manoj; Kumar, Sunil; Upadhyaya, Aditi; Yadav, Anjali; Gupta, Saral K.; Singh, Amarjeet</p> <p>2018-05-01</p> <p>Poly (3-hexylthiophene-2,5diyl) (P3HT) as donor and [6,6]-phenyl C61 butyric acid methyl ester (PCBM) as acceptor are mostly used as active medium in polymeric electronic device. In this paper we have prepare the P3HT - PCBM based bulk hetero junction thin films by spin coating technique. The charge transport properties of P3HT:PCBM blends are investigated by the current-voltage measurements using Ag as an electron injecting electrode and ITO as a hole injecting contact. The current density v/s voltage relationships are analyzed in the backdrop of Schottky and Space charge limited current model.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016ESASP.738E..34B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016ESASP.738E..34B"><span>Conducted-Susceptibility Testing as an Alternative Approach to Unit-Level Radiated-Susceptibility Verifications</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Badini, L.; Grassi, F.; Pignari, S. A.; Spadacini, G.; Bisognin, P.; Pelissou, P.; Marra, S.</p> <p>2016-05-01</p> <p>This work presents a theoretical rationale for the substitution of radiated-susceptibility (RS) verifications defined in current aerospace standards with an equivalent conducted-susceptibility (CS) test procedure based on bulk current injection (BCI) up to 500 MHz. Statistics is used to overcome the lack of knowledge about uncontrolled or uncertain setup parameters, with particular reference to the common-mode impedance of equipment. The BCI test level is properly investigated so to ensure correlation of currents injected in the equipment under test via CS and RS. In particular, an over-testing probability quantifies the severity of the BCI test with respect to the RS test.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26220059','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26220059"><span>Trends in Utilization of Vocal Fold Injection Procedures.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Rosow, David E</p> <p>2015-11-01</p> <p>Office-based vocal fold injections have become increasingly popular over the past 15 years. Examination of trends in procedure coding for vocal fold injections in the United States from 2000 to 2012 was undertaken to see if they reflect this shift. The US Part B Medicare claims database was queried from 2000 through 2012 for multiple Current Procedural Terminology codes. Over the period studied, the number of nonoperative laryngoscopic injections (31513, 31570) and operative medialization laryngoplasties (31588) remained constant. Operative vocal fold injection (31571) demonstrated marked linear growth over the 12-year study period, from 744 procedures in 2000 to 4788 in 2012-an increase >640%. The dramatic increased incidence in the use of code 31571 reflects an increasing share of vocal fold injections being performed in the operating room and not in an office setting, running counter to the prevailing trend toward awake, office-based injection procedures. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29912196','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29912196"><span>Trans-inner Cell Mass Injection of Embryonic Stem Cells Leads to Higher Chimerism Rates.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Scott, Gregory J; Gruzdev, Artiom; Hagler, Thomas B; Ray, Manas K</p> <p>2018-05-29</p> <p>In an effort to increase efficiency in the creation of genetically modified mice via ES Cell methodologies, we present an adaptation to the current blastocyst injection protocol. Here we report that a simple rotation of the embryo, and injection through Trans-Inner cell mass (TICM) increased the percentage of chimeric mice from 31% to 50%, with no additional equipment or further specialized training. 26 different inbred clones, and 35 total clones were injected over a period of 9 months. There was no significant difference in either pregnancy rate or recovery rate of embryos between traditional injection techniques and TICM. Therefore, without any major alteration in the injection process and a simple positioning of the blastocyst and injecting through the ICM, releasing the ES cells into the blastocoel cavity can potentially improve the quantity of chimeric production and subsequent germline transmission.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19980151108','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19980151108"><span>Construction of a Direct Water-Injected Two-Stroke Engine for Phased Direct Fuel Injection-High Pressure Charging Investigations</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Somsel, James P.</p> <p>1998-01-01</p> <p>The development of a water injected Orbital Combustion Process (OCP) engine was conducted to assess the viability of using the powerplant for high altitude NASA aircraft and General Aviation (GA) applications. An OCP direct fuel injected, 1.2 liter, three cylinder, two-stroke engine has been enhanced to independently inject water directly into the combustion chamber. The engine currently demonstrates low brake specific fuel consumption capability and an excellent power to weight ratio. With direct water injection, significant improvements can be made to engine power, to knock limits/ignition advance timing, and to engine NO(x) emissions. The principal aim of the testing was to validate a cyclic model developed by the Systems Analysis Branch at NASA Ames Research Center. The work is a continuation of Ames' investigations into a Phased Direct Fuel Injection Engine with High Pressure Charging (PDFI-ITPC).</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017PhRvP...8e4027B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017PhRvP...8e4027B"><span>Bias Dependence of the Electrical Spin Injection into GaAs from Co -Fe -B /MgO Injectors with Different MgO Growth Processes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Barate, P.; Liang, S. H.; Zhang, T. T.; Frougier, J.; Xu, B.; Schieffer, P.; Vidal, M.; Jaffrès, H.; Lépine, B.; Tricot, S.; Cadiz, F.; Garandel, T.; George, J. M.; Amand, T.; Devaux, X.; Hehn, M.; Mangin, S.; Tao, B.; Han, X. F.; Wang, Z. G.; Marie, X.; Lu, Y.; Renucci, P.</p> <p>2017-11-01</p> <p>We investigate the influence of the MgO growth process on the bias dependence of the electrical spin injection from a Co -Fe -B /MgO spin injector into a GaAs-based light-emitting diode (spin LED). With this aim, textured MgO tunnel barriers are fabricated either by sputtering or molecular-beam-epitaxy (MBE) methods. For the given growth parameters used for the two techniques, we observe that the circular polarization of the electroluminescence emitted by spin LEDs is rather stable as a function of the injected current or applied bias for the samples with sputtered tunnel barriers, whereas the corresponding circular polarization decreases abruptly for tunnel barriers grown by MBE. We attribute these different behaviors to the different kinetic energies of the injected carriers linked to differing amplitudes of the parasitic hole current flowing from GaAs to Co-Fe-B in both cases.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017APS..MARX42009J','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017APS..MARX42009J"><span>Non-local opto-electrical spin injection and detection in germanium at room temperature</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Jamet, Matthieu; Rortais, Fabien; Zucchetti, Carlo; Ghirardini, Lavinia; Ferrari, Alberto; Vergnaud, Celine; Widiez, Julie; Marty, Alain; Attane, Jean-Philippe; Jaffres, Henri; George, Jean-Marie; Celebrano, Michele; Isella, Giovanni; Ciccacci, Franco; Finazzi, Marco; Bottegoni, Federico</p> <p></p> <p>Non-local charge carriers injection/detection schemes lie at the foundation of information manipulation in integrated systems. The next generation electronics may operate on the spin instead of the charge and germanium appears as the best hosting material to develop such spintronics for its compatibility with mainstream silicon technology and long spin lifetime at room temperature. Moreover, the energy proximity between the direct and indirect bandgaps allows for optical spin orientation. In this presentation, we demonstrate injection of pure spin currents in Ge, combined with non-local spin detection blocks at room temperature. Spin injection is performed either electrically through a magnetic tunnel junction (MTJ) or optically, by using lithographed nanostructures to diffuse the light and create an in-plane polarized electron spin population. Pure spin current detection is achieved using either a MTJ or the inverse spin-Hall effect across a Pt stripe. Supported by the ANR project SiGeSPIN #ANR-13-BS10-0002 and the CARIPLO project SEARCH-IV (Grant 2013-0623).</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26318394','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26318394"><span>[Definition of botulinum toxin failure in neurogenic detrusor overactivity: Preliminary results of the DETOX survey].</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Peyronnet, B; Sanson, S; Amarenco, G; Castel-Lacanal, E; Chartier-Kastler, E; Charvier, K; Damphousse, M; Denys, P; de Seze, M; Egon, G; Even, A; Forin, V; Karsenty, G; Kerdraon, J; le Normand, L; Loche, C-M; Manunta, A; Mouracade, P; Phe, V; Previnaire, J-G; Ruffion, A; Saussine, C; Schurch, B; Game, X</p> <p>2015-12-01</p> <p>There is currently no guideline regarding the management of neurogenic detrusor overactivity (NDO) refractory to intra-detrusor botulinum toxin injections. The primary objective of the present study was to find a consensus definition of failure of botulinum toxin intra-detrusor injections for NDO. The secondary objective was to report current trends in the managment of NDO refractory to botulinum toxin. A survey was created, based on data drawn from current literature, and sent via e-mail to all the experts form the Group for research in neurourology in french language (GENULF) and from the comittee of neurourology of the French urological association (AFU). The experts who did not answer to the first e-mail were contacted again twice. Main results from the survey are presented and expressed as numbers and proportions. Out of the 42 experts contacted, 21 responded to the survey. Nineteen participants considered that the definition of failure should be a combination of clinical and urodynamics criteria. Among the urodynamics criteria, the persistence of a maximum detrusor pressure>40 cm H2O was the most supported by the experts (18/21, 85%). According to the vast majority of participants (19/21, 90.5%), the impact of injections on urinary incontinence should be included in the definition of failure. Regarding the management, most experts considered that the first line treatment in case of failure of a first intra-detrusor injection of Botox(®) 200 U should be a repeat injection of Botox(®) at a higher dosage (300 U) (15/20, 75%), regardless of the presence or not of urodynamics risk factors of upper tract damage (16/20, 80%). This work has provided a first overview of the definition of failure of intra-detrusor injections of botulinum toxin in the management of NDO. For 90.5% of the experts involved, the definition of failure should be clinical and urodynamic and most participants (75%) considered that, in case of failure of a first injection of Botox(®) 200 U, repeat injection of Botox(®) 300 U should be the first line treatment. Copyright © 2015 Elsevier Masson SAS. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/7275159','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/biblio/7275159"><span>Integrated injection-locked semiconductor diode laser</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Hadley, G.R.; Hohimer, J.P.; Owyoung, A.</p> <p>1991-02-19</p> <p>A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet. 18 figures.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=19860053573&hterms=injection+molding&qs=N%3D0%26Ntk%3DAll%26Ntx%3Dmode%2Bmatchall%26Ntt%3Dinjection%2Bmolding','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=19860053573&hterms=injection+molding&qs=N%3D0%26Ntk%3DAll%26Ntx%3Dmode%2Bmatchall%26Ntt%3Dinjection%2Bmolding"><span>Processing study of injection molding of silicon nitride for engine applications</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Rorabaugh, M. E.; Yeh, H. C.</p> <p>1985-01-01</p> <p>The high hardness of silicon nitride, which is currently under consideration as a structural material for such hot engine components as turbine blades, renders machining of the material prohibitively costly; the near net shape forming technique of injection molding is accordingly favored as a means for component fabrication. Attention is presently given to the relationships between injection molding processing parameters and the resulting microstructural and mechanical properties of the resulting engine parts. An experimental program has been conducted under NASA sponsorship which tests the quality of injection molded bars of silicon nitride at various stages of processing.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1999Natur.402..787F','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1999Natur.402..787F"><span>Injection and detection of a spin-polarized current in a light-emitting diode</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Fiederling, R.; Keim, M.; Reuscher, G.; Ossau, W.; Schmidt, G.; Waag, A.; Molenkamp, L. W.</p> <p>1999-12-01</p> <p>The field of magnetoelectronics has been growing in practical importance in recent years. For example, devices that harness electronic spin-such as giant-magnetoresistive sensors and magnetoresistive memory cells-are now appearing on the market. In contrast, magnetoelectronic devices based on spin-polarized transport in semiconductors are at a much earlier stage of development, largely because of the lack of an efficient means of injecting spin-polarized charge. Much work has focused on the use of ferromagnetic metallic contacts, but it has proved exceedingly difficult to demonstrate polarized spin injection. More recently, two groups have reported successful spin injection from an NiFe contact, but the observed effects of the spin-polarized transport were quite small (resistance changes of less than 1%). Here we describe a different approach, in which the magnetic semiconductor BexMnyZn1-x-ySe is used as a spin aligner. We achieve injection efficiencies of 90% spin-polarized current into a non-magnetic semiconductor device. The device used in this case is a GaAs/AlGaAs light-emitting diode, and spin polarization is confirmed by the circular polarization state of the emitted light.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/11427899','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/11427899"><span>Blockade of hyperpolarizing currents produces a dose-dependent effect on heart rate.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ziyatdinova, N I; Giniatullin, R A; Svyatova, N V; Zefirov, T L</p> <p>2001-03-01</p> <p>Intravenous injection of ZD 7288, a new specific hyperpolarizing current blocker, dose-dependently reduces heart rate in adult rats. The autonomic nervous system modulates changes in heart rate caused by hyperpolarizing currents.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_23 --> <div id="page_24" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="461"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1985ITM....21..916V','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1985ITM....21..916V"><span>Superconducting current injection transistor with very high critical-current-density edge-junctions</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>van Zeghbroeck, B. J.</p> <p>1985-03-01</p> <p>A Superconducting Current Injection Transistor (Super-CIT) was fabricated with very high critical current-density edge-junctions. The junctions have a niobium base electrode and a lead-alloy counter electrode. The length of the junctions is 30 microns and the critical-current density is 190KA/sq cm. The Super-CIT has a current gain of 2, a large signal transresistance of 100 mV/A, and the turn-on delay, inferred from the junction resonance, is 7ps. The power dissipation is 3.5 microwatts and the power-delay product is 24.5aJ. Gap reduction due to heating was observed, limiting the maximum power dissipation per unit length to 1.1 microwatt/micron. Compared to lead-alloy Super-CITs, the device is five times smaller, three times faster, and has a three times larger output voltage. The damping resistor and the contact junction could also be eliminated.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26135502','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26135502"><span>Electron beam induced current in the high injection regime.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Haney, Paul M; Yoon, Heayoung P; Koirala, Prakash; Collins, Robert W; Zhitenev, Nikolai B</p> <p>2015-07-24</p> <p>Electron beam induced current (EBIC) is a powerful technique which measures the charge collection efficiency of photovoltaics with sub-micron spatial resolution. The exciting electron beam results in a high generation rate density of electron-hole pairs, which may drive the system into nonlinear regimes. An analytic model is presented which describes the EBIC response when the total electron-hole pair generation rate exceeds the rate at which carriers are extracted by the photovoltaic cell, and charge accumulation and screening occur. The model provides a simple estimate of the onset of the high injection regime in terms of the material resistivity and thickness, and provides a straightforward way to predict the EBIC lineshape in the high injection regime. The model is verified by comparing its predictions to numerical simulations in one- and two-dimensions. Features of the experimental data, such as the magnitude and position of maximum collection efficiency versus electron beam current, are consistent with the three-dimensional model.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018SPIE10553E..1GM','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018SPIE10553E..1GM"><span>Comparison for 1030nm DBR-tapered diode lasers with 10W central lobe output power and different grating layouts for wavelength stabilization and lateral spatial mode filtering</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Müller, André; Zink, Christof; Fricke, Jörg; Bugge, Frank; Erbert, Götz; Sumpf, Bernd; Tränkle, Günther</p> <p>2018-02-01</p> <p>1030 nm DBR tapered diode lasers with different lateral layouts are presented. The layout comparison includes lasers with straight waveguide and grating, tapered waveguide and straight grating, and straight waveguide and tapered grating. The lasers provide narrowband emission and optical output powers up to 15 W. The highest diffraction-limited central lobe output power of 10.5 W is obtained for lasers with tapered gratings only. Small variations in central lobe output power with RW injection current density also indicate the robustness of that layout. For lasers with tapered waveguides, high RW injection current densities up to 150 A/mm2 have to be applied in order to obtain high central lobe output powers. Lasers with straight waveguide and grating operate best at low RW injection current densities, 50 A/mm2 applied in this study. Using the layout optimizations discussed in this study may help to increase the application potential of DBR tapered diode lasers.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22453427','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22453427"><span>Alternative laser system for cesium magneto-optical trap via optical injection locking to sideband of a 9-GHz current-modulated diode laser.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Diao, Wenting; He, Jun; Liu, Zhi; Yang, Baodong; Wang, Junmin</p> <p>2012-03-26</p> <p>By optical injection of an 852-nm extended-cavity diode laser (master laser) to lock the + 1-order sideband of a ~9-GHz-current-modulated diode laser (slave laser), we generate a pair of phase-locked lasers with a frequency difference up to ~9-GHz for a cesium (Cs) magneto-optical trap (MOT) with convenient tuning capability. For a cesium MOT, the master laser acts as repumping laser, locked to the Cs 6S₁/₂ (F = 3) - 6P₃/₂ (F' = 4) transition. When the + 1-order sideband of the 8.9536-GHz-current-modulated slave laser is optically injection-locked, the carrier operates on the Cs 6S₁/₂ (F = 4) - 6P₃/₂ (F' = 5) cooling cycle transition with -12 MHz detuning and acts as cooling/trapping laser. When carrying a 9.1926-GHz modulation signal, this phase-locked laser system can be applied in the fields of coherent population trapping and coherent manipulation of Cs atomic ground states.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2000APS..DPPMP1102S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2000APS..DPPMP1102S"><span>Multi-pulse power injection and spheromak sustainment in SSPX</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Stallard, B. W.; Hill, D. N.; Hooper, E. B.; Bulmer, R. H.; McLean, H. S.; Wood, R. D.; Woodruff, S.; Sspx Team</p> <p>2000-10-01</p> <p>Lawrence Livermore National Laboratory, Livermore, CA 94550, USA. Spheromak formation (gun injection phase) and sustainment experiments are now routine in SSPX using a multi-bank power system. Gun voltage, impedance, and power coupling show a clear current threshold dependence on gun flux (I_th~=λ_0φ_gun/μ_0), increasing with current above the threshold, and are compared with CTX results. The characteristic gun inductance, L_gun~=0.6 μH, derived from the gun voltage dependence on di/dt, is larger than expected from Corsica modeling of the spheromak equilibrium. It’s value is consistent with the n=1 ‘doughook’ mode structure reported in SPHEX and believed important for helicity injection and toroidal current drive. Results of helicity and power balance calculations of spheromak poloidal field buildup are compared with experiment and used to project sustainment with a future longer pulse power supply. This work was performed under the auspices of US DOE by the University of California Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22645505-local-injection-emitted-electrons-micrograins-surface-sup-iii-sup-semiconductors','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22645505-local-injection-emitted-electrons-micrograins-surface-sup-iii-sup-semiconductors"><span>On the local injection of emitted electrons into micrograins on the surface of A{sup III}–B{sup V} semiconductors</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Zhukov, N. D., E-mail: ndzhukov@rambler.ru; Glukhovskoi, E. G.; Khazanov, A. A.</p> <p>2016-06-15</p> <p>The characteristics of the injection of electrons into a semiconductor from a microprobe–micrograin nanogap are investigated with a tunneling microscope in the mode of field emission into locally selected surface microcrystals of indium antimonide, indium arsenide, and gallium arsenide. The current mechanisms are established and their parameters are determined by comparing the experimental I–V characteristics and those calculated from formulas of current transport. The effect of limitation of the current into the micrograins of indium antimonide and indium arsenide which manifests itself at injection levels exceeding a certain critical value, e.g., 6 × 10{sup 16} cm{sup –3} for indium antimonidemore » and 4 × 10{sup 17} cm{sup –3} for indium arsenide, is discovered. A physical model, i.e., the localization of electrons in the surface area of a micrograin due to their Coulomb interaction, is proposed.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3140313','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3140313"><span>A redesigned follitropin alfa pen injector for infertility: results of a market research study</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Abbotts, Carole; Salgado-Braga, Cristiana; Audibert-Gros, Céline</p> <p>2011-01-01</p> <p>Background: The purpose of this study was to evaluate patient-learning and nurse-teaching experiences when using a redesigned prefilled, ready-to-use follitropin alfa pen injector. Methods: Seventy-three UK women of reproductive age either administering daily treatment with self-injectable gonadotropins or about to start gonadotropin treatment for infertility (aged 24–47 years; 53 self-injection-experienced and 20 self-injection-naïve) and 28 nurses from UK infertility clinics were recruited for the study. Following instruction, patients and nurses used the redesigned follitropin alfa pen to inject water into an orange and completed questionnaires to evaluate their experiences with the pen immediately after the simulated injections. Results: Most (88%, n = 64) patients found it easy to learn how to use the pen. Among injection-experienced patients, 66% (n = 35) agreed that the redesigned pen was easier to learn to use compared with their current method and 70% (n = 37) also said they would prefer its use over current devices for all injectable fertility medications. All nurses considered the redesigned pen easy to learn and believed it would be easy to teach patients how to use. Eighty-six percent (n = 24) of the nurses thought it was easy to teach patients to determine the remaining dose to be dialed and injected in a second pen if the initial dose was incomplete. Compared with other injection devices, 96% (n = 27) thought it was “much easier” to “as easy” to teach patients to use the redesigned pen. Based on ease of teaching, 68% (n = 19) of nurses would choose to teach the pen in preference to any other injection method. Almost all (93%, n = 26) nurses considered that having the same pen format for a range of injectable gonadotropins would facilitate teaching and learning self-injection. Conclusion: In this market research study with infertile patients and infertility nurses, the redesigned follitropin alfa pen was perceived as easy to learn, easy to teach how to use, and well accepted. PMID:21792303</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29769132','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29769132"><span>Toots, tastes and tester shots: user accounts of drug sampling methods for gauging heroin potency.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Mars, Sarah G; Ondocsin, Jeff; Ciccarone, Daniel</p> <p>2018-05-16</p> <p>Internationally, overdose is the primary cause of death among people injecting drugs. However, since 2001, heroin-related overdose deaths in the United States (US) have risen sixfold, paralleled by a rise in the death rate attributed to synthetic opioids, particularly the fentanyls. This paper considers the adaptations some US heroin injectors are making to protect themselves from these risks. Between 2015 and 2016, a team of ethnographers collected data through semi-structured interviews and observation captured in field notes and video recording of heroin preparation/consumption. Ninety-one current heroin injectors were interviewed (Baltimore, n = 22; Chicago, n = 24; Massachusetts and New Hampshire, n = 36; San Francisco, n = 9). Experience injecting heroin ranged from < 1-47 years. Eight participants, who were exclusively heroin snorters, were also interviewed. Data were analyzed thematically. Across the study sites, multiple methods of sampling "heroin" were identified, sometimes used in combination, ranging from non-injecting routes (snorting, smoking or tasting a small amount prior to injection) to injecting a partial dose and waiting. Partial injection took different forms: a "slow shot" where the user injected a portion of the solution in the syringe, keeping the needle in the injection site, and continuing or withdrawing the syringe or a "tester shot" where the solution was divided into separate injections. Other techniques included getting feedback from others using heroin of the same batch or observing those with higher tolerance injecting heroin from the same batch before judging how much to inject themselves. Although a minority of those interviewed described using these drug sampling techniques, there is clearly receptivity among some users to protecting themselves by using a variety of methods. The use of drug sampling as a means of preventing an overdose from injection drug use reduces the quantity absorbed at any one time allowing users to monitor drug strength and titrate their dose accordingly. Given the highly unpredictable potency of the drugs currently being sold as heroin in the US, universal precautions should be adopted more widely. Further research is needed into facilitators and barriers to the uptake of these drug sampling methods.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2011InvPr..27g5004S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2011InvPr..27g5004S"><span>Optimal geometry toward uniform current density electrodes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Song, Yizhuang; Lee, Eunjung; Woo, Eung Je; Seo, Jin Keun</p> <p>2011-07-01</p> <p>Electrodes are commonly used to inject current into the human body in various biomedical applications such as functional electrical stimulation, defibrillation, electrosurgery, RF ablation, impedance imaging, and so on. When a highly conducting electrode makes direct contact with biological tissues, the induced current density has strong singularity along the periphery of the electrode, which may cause painful sensation or burn. Especially in impedance imaging methods such as the magnetic resonance electrical impedance tomography, we should avoid such singularity since more uniform current density underneath a current-injection electrode is desirable. In this paper, we study an optimal geometry of a recessed electrode to produce a well-distributed current density on the contact area under the electrode. We investigate the geometry of the electrode surface to minimize the edge singularity and produce nearly uniform current density on the contact area. We propose a mathematical framework for the uniform current density electrode and its optimal geometry. The theoretical results are supported by numerical simulations.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22085988-simulation-current-filament-dynamics-relaxation-pegasus-spherical-tokamak','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22085988-simulation-current-filament-dynamics-relaxation-pegasus-spherical-tokamak"><span>Simulation of current-filament dynamics and relaxation in the Pegasus Spherical Tokamak</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>O'Bryan, J. B.; Sovinec, C. R.; Bird, T. M.</p> <p></p> <p>Nonlinear numerical computation is used to investigate the relaxation of non-axisymmetric current-channels from washer-gun plasma sources into 'tokamak-like' plasmas in the Pegasus toroidal experiment [Eidietis et al. J. Fusion Energy 26, 43 (2007)]. Resistive MHD simulations with the NIMROD code [Sovinec et al. Phys. Plasmas 10(5), 1727-1732 (2003)] utilize ohmic heating, temperature-dependent resistivity, and anisotropic, temperature-dependent thermal conduction corrected for regions of low magnetization to reproduce critical transport effects. Adjacent passes of the simulated current-channel attract and generate strong reversed current sheets that suggest magnetic reconnection. With sufficient injected current, adjacent passes merge periodically, releasing axisymmetric current rings from themore » driven channel. The current rings have not been previously observed in helicity injection for spherical tokamaks, and as such, provide a new phenomenological understanding for filament relaxation in Pegasus. After large-scale poloidal-field reversal, a hollow current profile and significant poloidal flux amplification accumulate over many reconnection cycles.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1988QuEle..18.1402H','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1988QuEle..18.1402H"><span>INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: High-frequency impedance and spontaneous carrier lifetime in narrow-stripe semiconductor injection lasers</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Hoernlein, W.</p> <p>1988-11-01</p> <p>Measurements were made of the complex reflection coefficient of hf (10-400 MHz) signals from semiconductor injection lasers supplied with a direct bias current ranging from several milliamperes up to the threshold value or higher. The hf impedance was calculated. The parameters of the equivalent electrical circuit made it possible to predict the modulation characteristics. The impedance corresponding to currents below the lasing threshold was used to find the differential carrier lifetime from the RC constant of the p-n junction of a laser diode. A description of the apparatus is supplemented by an account of the method used in calculation of the electrical parameters and carrier lifetimes. The first results obtained using this apparatus and method are reported.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1026662','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/1026662"><span>Method for enhancing selectivity and recovery in the fractional flotation of particles in a flotation column</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Klunder, Edgar B [Bethel Park, PA</p> <p>2011-08-09</p> <p>The method relates to particle separation from a feed stream. The feed stream is injected directly into the froth zone of a vertical flotation column in the presence of a counter-current reflux stream. A froth breaker generates a reflux stream and a concentrate stream, and the reflux stream is injected into the froth zone to mix with the interstitial liquid between bubbles in the froth zone. Counter-current flow between the plurality of bubbles and the interstitial liquid facilitates the attachment of higher hydrophobicity particles to bubble surfaces as lower hydrophobicity particles detach. The height of the feed stream injection and the reflux ratio may be varied in order to optimize the concentrate or tailing stream recoveries desired based on existing operating conditions.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5087101','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5087101"><span>Diabetic Macular Edema: From Old Concepts to New Therapeutic Avenues</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Mansour, Ahmad M; Pulido, Jose S; Arevalo, J Fernando</p> <p>2015-01-01</p> <p>Diabetic macular edema (DME) is a significant cause of blindness in the working population and is currently challenging to treat. Current interventions include focal laser or intravitreal injections. This article outlines a new treatment protocol based on the theory that peripheral ischemia is the precursor to angiogenesis, which will ultimately gather its momentum at the fovea. Extreme peripheral light laser panretinal photocoagulation (PRP) back to the equator reduces excessive production of the vascular endothelial growth factor (VEGF) in the eye. This decreases VEGF-induced DME and provides long-term protection against the development of neovascularization. Initial exacerbation of DME often accompanies PRP. Therefore, injections of anti-VEGF agents (with or without dexamethasone implants) initially can forestall worsening of DME and prevent loss of vision. However, on the other hand, applying peripheral PRP and intraocular injections can induce posterior vitreous detachment (PVD). This could help release vitreomacular adhesions (VMA) and vitreomacular traction (VMT), thereby decreasing DME severity and improving the response to intravitreal injections. In the current approach, peripheral retinal photocoagulation should stop the drive for VEGF release; moreover, laser ablation should produce secondary, accidental, and beneficial PVD. This approach precludes focal laser therapy and paves the path for prolonged intervals between anti-VEGF therapy. PMID:27800500</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=1810522','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=1810522"><span>Public health the leading force of the Indonesian response to the HIV/AIDS crisis among people who inject drugs</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Mesquita, Fabio; Winarso, Inang; Atmosukarto, Ingrid I; Eka, Bambang; Nevendorff, Laura; Rahmah, Amala; Handoyo, Patri; Anastasia, Priscillia; Angela, Rosi</p> <p>2007-01-01</p> <p>Issue Indonesia has an explosive HIV/AIDS epidemic starting from the beginning of this century, and it is in process to build its response. Reported AIDS cases doubled from 2003 – 2004, and approximately 54% of these cases are in people who inject drugs. Setting Indonesia is the 4th largest country in population in the world, a predominantly Muslim country with strong views on drug users and people living with HIV/AIDS. Globally speaking, Indonesia has one of the most explosive epidemics in recent years. The project IHPCP (Indonesia HIV/AIDS Prevention and Care Project) is a joint support project (primarily AusAID-based) that works in partnership with the Government of Indonesia. IHPCP has been a key player of in the country's response, particularly pioneering NSP; stimulating and supporting methadone programs, and being key in promoting ARV for people who currently inject drugs. The project works via both the public health system and NGOs. Outcomes It is still early to measure the impact of current interventions; however, this paper describes the current status of Indonesia's response to the HIV/AIDS crisis among people who inject drugs, and analyses future challenges of the epidemic in Indonesia. PMID:17306033</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2012APS..DPPNP8064T','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2012APS..DPPNP8064T"><span>Improved Density Control in the Pegasus Toroidal Experiment using Internal Fueling</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Thome, K. E.; Bongard, M. W.; Cole, J. A.; Fonck, R. J.; Redd, A. J.; Winz, G. R.</p> <p>2012-10-01</p> <p>Routine density control up to and exceeding the Greenwald limit is critical to key Pegasus operational scenarios, including non-solenoidal startup plasmas created using single-point helicity injection and high β Ohmic plasmas. Confinement scalings suggest it is possible to achieve very high β plasmas in Pegasus by lowering the toroidal field and increasing ne/ng. In the past, Pegasus achieved β ˜ 20% in high recycling Ohmic plasmas without running into any operational boundaries.footnotetext Garstka, G.D. et al., Phys. Plasmas 10, 1705 (2003) However, recent Ohmic experiments have demonstrated that Pegasus currently operates in an extremely low-recycling regime with R < 0.8 and Zeff ˜ 1 using improved vacuum conditioning techniques, such as Ti gettering and cryogenic pumping. Hence, it is difficult to achieve ne/ng> 0.3 with these improved wall conditions. Presently, gas is injected using low-field side (LFS) modified PV-10 valves. To attain high ne/ng operation and coincidentally separate core plasma and local current source fueling two new gas fueling capabilities are under development. A centerstack capillary injection system has been commissioned and is undergoing initial tests. A LFS movable midplane needle gas injection system is currently under design and will reach r/a ˜ 0.25. Initial results from both systems will be presented.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2005APS..DPPGP1079H','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2005APS..DPPGP1079H"><span>Spheromak plasma flow injection into a torus chamber and the HIST plasmas</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Hatuzaki, Akinori</p> <p>2005-10-01</p> <p>The importance of plasma flow or two-fluid effect is recognized in understanding the relaxed states of high-beta torus plasmas, start-up and current drive by non-coaxial helicity injection, magnetic reconnection and plasma dynamo in fusion, laboratory and space plasmas. As a new approach to create a flowing two-fluid plasma equilibrium, we have tried to inject tangentially the plasma flow with spheromak-type magnetic configurations into a torus vacuum chamber with an external toroidal magnetic field (TF) coil. In the initial experiments, the RFP-like configuration with helical magnetic structures was realized in the torus vessel. The ion flow measurement with Mach probes showed that the ion flow keeps the same direction despite the reversal of the toroidal current and the axial electric field. The ion fluid comes to flow in the opposite direction to the electron fluid by the reversal of TF. This result suggests that not only electron but also ion flow contributes significantly on the reversed toroidal current. In this case, the ratio of ui to the electron flow velocity ue is estimated as ui/ue ˜ 1/2. We also will inject the spheromak flow into the HIST spherical torus plasmas to examine the possibilities to embedding the two-fluid effect in the ST plasmas.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19920002680','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19920002680"><span>A simulation study of interactions of Space-Shuttle generated electron beams with ambient plasma and neutral gas</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p></p> <p>1991-01-01</p> <p>The object was to conduct large scale simulations of electron beams injected into space. The study of active injection of electron beams from spacecraft is important since it provides valuable insight into beam-plasma interactions and the development of current systems in the ionosphere. However, the beam injection itself is not simple, being constrained by the ability of the spacecraft to draw return current from the ambient plasma. The generation of these return currents is dependent on several factors, including the density of the ambient plasma relative to the beam density, the presence of neutrals around the spacecraft, the configuration of the spacecraft, and the motion of the spacecraft through the plasma. Two dimensional particle simulations with collisional processes included are used to show how these different and often coupled processes can be utilized to enhance beam propagation from the spacecraft. To understand the radical expansion of mechanism of an electron beam from a highly charged spacecraft, two dimensional particle in cell simulations were conducted for a high density electron beam injected parallel to magnetic fields from an isolated equipotential conductor into a cold background plasma. The simulations indicate that charge buildup at the beam stagnation point causes the beam to expand radially to the beam electron gyroradius.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=20110013511&hterms=bats&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D20%26Ntt%3Dbats','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=20110013511&hterms=bats&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D20%26Ntt%3Dbats"><span>Dynamics of Ring Current and Electric Fields in the Inner Magnetosphere During Disturbed Periods: CRCM-BATS-R-US Coupled Model</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Buzulukova, N.; Fok, M.-C.; Pulkkinen, A.; Kuznetsova, M.; Moore, T. E.; Glocer, A.; Brandt, P. C.; Toth, G.; Rastaetter, L.</p> <p>2010-01-01</p> <p>We present simulation results from a one-way coupled global MHD model (Block-Adaptive-Tree Solar-Wind Roe-Type Upwind Scheme, BATS-R-US) and kinetic ring current models (Comprehensive Ring Current Model, CRCM, and Fok Ring Current, FokRC). The BATS-R-US provides the CRCM/FokRC with magnetic field information and plasma density/temperature at the polar CRCM/FokRC boundary. The CRCM uses an electric potential from the BATS-R-US ionospheric solver at the polar CRCM boundary in order to calculate the electric field pattern consistent with the CRCM pressure distribution. The FokRC electric field potential is taken from BATS-R-US ionospheric solver everywhere in the modeled region, and the effect of Region II currents is neglected. We show that for an idealized case with southward-northward-southward Bz IMF turning, CRCM-BATS-R-US reproduces well known features of inner magnetosphere electrodynamics: strong/weak convection under the southward/northward Bz; electric field shielding/overshielding/penetration effects; an injection during the substorm development; Subauroral Ion Drift or Polarization Jet (SAID/PJ) signature in the dusk sector. Furthermore, we find for the idealized case that SAID/PJ forms during the substorm growth phase, and that substorm injection has its own structure of field-aligned currents which resembles a substorm current wedge. For an actual event (12 August 2000 storm), we calculate ENA emissions and compare with Imager for Magnetopause-to-Aurora Global Exploration/High Energy Neutral Atom data. The CRCM-BATS-R-US reproduces both the global morphology of ring current and the fine structure of ring current injection. The FokRC-BATS-R-US shows the effect of a realistic description of Region II currents in ring current-MHD coupled models.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1035061','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/1035061"><span>Optoelectronic device with nanoparticle embedded hole injection/transport layer</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Wang, Qingwu [Chelmsford, MA; Li, Wenguang [Andover, MA; Jiang, Hua [Methuen, MA</p> <p>2012-01-03</p> <p>An optoelectronic device is disclosed that can function as an emitter of optical radiation, such as a light-emitting diode (LED), or as a photovoltaic (PV) device that can be used to convert optical radiation into electrical current, such as a photovoltaic solar cell. The optoelectronic device comprises an anode, a hole injection/transport layer, an active layer, and a cathode, where the hole injection/transport layer includes transparent conductive nanoparticles in a hole transport material.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1045177','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1045177"><span>Booster Synchrotron RF System Upgrade for SPEAR3</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Park, Sanghyun; /SLAC; Corbett, Jeff</p> <p>2012-07-06</p> <p>Recent progress at the SPEAR3 includes the increase in stored current from 100 mA to 200 mA and top-off injection to allow beamlines to stay open during injection. Presently the booster injects 3.0 GeV beam to SPEAR3 three times a day. The stored beam decays to about 150 mA between the injections. The growing user demands are to increase the stored current to the design value of 500 mA, and to maintain it at a constant value within a percent or so. To achieve this goal the booster must inject once every few minutes. For improved injection efficiency, all RFmore » systems at the linac, booster and SPEAR3 need to be phase-locked. The present booster RF system is basically a copy of the SPEAR2 RF system with 358.5 MHz and 40 kW peak RF power driving a 5-cell RF cavity for 1.0 MV gap voltage. These requirements entail a booster RF system upgrade to a scaled down version of the SPEAR3 RF system of 476.3 MHz with 1.2 MW cw klystron output power capabilities. We will analyze each subsystem option for their merits within budgetary and geometric space constraints. A substantial portion of the system will come from the decommissioned PEP-II RF stations.« less</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_24 --> <div id="page_25" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="481"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018PhyC..550...39B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018PhyC..550...39B"><span>Interplay between current driven ferromagnetism in charge ordered antiferromagnetic Pr0.5Ca0.5MnO3 and superconducting YBa2Cu3O7-δ thin film multilayer</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Baisnab, Dipak Kumar; Sardar, Manas; Amaladass, E. P.; Vaidhyanathan, L. S.; Baskaran, R.</p> <p>2018-07-01</p> <p>Thin film multilayer heterostructure of alternate YBa2Cu3O7-δ (YBCO) and Pr0.5Ca0.5MnO3 (PCMO) with thickness of each layer ∼60 nm has been deposited on (100) oriented SrTiO3 substrate by Pulsed Laser Deposition technique. A half portion of the base YBCO layer was masked in situ using mechanical shadow mask and in the remaining half portion, five alternate layers of PCMO and YBCO thin films were deposited. Magnetoresistance measurements were carried out under externally applied magnetic field and injection current. A noticeable damped oscillation of the superconducting transition temperature (TC) of this multilayer with respect to magnetic field is seen. Curiously, the field at which the first minimum in TC occurs, decreases as an injection current is driven perpendicular/parallel to the multilayers. Both these phenomena indicate that ferromagnetic correlation can be induced in antiferromagnetic PCMO thin films by (1) external magnetic field, or (2) injection current. While (1) is well researched, our study indicates that ferromagnetism can be induced by small amount of current in PCMO thin films. This unusual behavior points towards the strongly correlated nature of electrons in PCMO.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016PhPl...23e2515H','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016PhPl...23e2515H"><span>Impedance of an intense plasma-cathode electron source for tokamak startup</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Hinson, E. T.; Barr, J. L.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Perry, J. M.</p> <p>2016-05-01</p> <p>An impedance model is formulated and tested for the ˜1 kV , 1 kA/cm2 , arc-plasma cathode electron source used for local helicity injection tokamak startup. A double layer sheath is established between the high-density arc plasma ( narc≈1021 m-3 ) within the electron source, and the less dense external tokamak edge plasma ( nedge≈1018 m-3 ) into which current is injected at the applied injector voltage, Vinj . Experiments on the Pegasus spherical tokamak show that the injected current, Iinj , increases with Vinj according to the standard double layer scaling Iinj˜Vinj3 /2 at low current and transitions to Iinj˜Vinj1 /2 at high currents. In this high current regime, sheath expansion and/or space charge neutralization impose limits on the beam density nb˜Iinj/Vinj1 /2 . For low tokamak edge density nedge and high Iinj , the inferred beam density nb is consistent with the requirement nb≤nedge imposed by space-charge neutralization of the beam in the tokamak edge plasma. At sufficient edge density, nb˜narc is observed, consistent with a limit to nb imposed by expansion of the double layer sheath. These results suggest that narc is a viable control actuator for the source impedance.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2011APS..DPPCP9108K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2011APS..DPPCP9108K"><span>Nonlinear MHD simulation of current drive by multi-pulsed coaxial helicity injection in spherical torus</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Kanki, Takashi; Nagata, Masayoshi; Kagei, Yasuhiro</p> <p>2011-10-01</p> <p>The dynamics of structures of magnetic field, current density, and plasma flow generated during multi-pulsed coaxial helicity injection in spherical torus is investigated by 3-D nonlinear MHD simulations. During the driven phase, the flux and current amplifications occur due to the merging and magnetic reconnection between the preexisting plasma in the confinement region and the ejected plasma from the gun region involving the n = 1 helical kink distortion of the central open flux column (COFC). Interestingly, the diamagnetic poloidal flow which tends toward the gun region is then observed due to the steep pressure gradients of the COFC generated by ohmic heating through an injection current winding around the inboard field lines, resulting in the formation of the strong poloidal flow shear at the interface between the COFC and the core region. This result is consistent with the flow shear observed in the HIST. During the decay phase, the configuration approaches the axisymmetric MHD equilibrium state without flow because of the dissipation of magnetic fluctuation energy to increase the closed flux surfaces, suggesting the generation of ordered magnetic field structure. The parallel current density λ concentrated in the COFC then diffuses to the core region so as to reduce the gradient in λ, relaxing in the direction of the Taylor state.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018NucFu..58e6006S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018NucFu..58e6006S"><span>Dissipation of post-disruption runaway electron plateaus by shattered pellet injection in DIII-D</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Shiraki, D.; Commaux, N.; Baylor, L. R.; Cooper, C. M.; Eidietis, N. W.; Hollmann, E. M.; Paz-Soldan, C.; Combs, S. K.; Meitner, S. J.</p> <p>2018-05-01</p> <p>We report on the first demonstration of dissipation of fully avalanched post-disruption runaway electron (RE) beams by shattered pellet injection in the DIII-D tokamak. Variation of the injected species shows that dissipation depends strongly on the species mixture, while comparisons with massive gas injection do not show a significant difference between dissipation by pellets or by gas, suggesting that the shattered pellet is rapidly ablated by the relativistic electrons before significant radial penetration into the runaway beam can occur. Pure or dominantly neon injection increases the RE current dissipation through pitch-angle scattering due to collisions with impurity ions. Deuterium injection is observed to have the opposite effect from neon, reducing the high-Z impurity content and thus decreasing the dissipation, and causing the background thermal plasma to completely recombine. When injecting mixtures of the two species, deuterium levels as low as  ∼10% of the total injected atoms are observed to adversely affect the resulting dissipation, suggesting that complete elimination of deuterium from the injection may be important for optimizing RE mitigation schemes.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/1432365-dissipation-post-disruption-runaway-electron-plateaus-shattered-pellet-injection-diii','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/1432365-dissipation-post-disruption-runaway-electron-plateaus-shattered-pellet-injection-diii"><span>Dissipation of post-disruption runaway electron plateaus by shattered pellet injection in DIII-D</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Shiraki, D.; Commaux, N.; Baylor, L. R.</p> <p></p> <p>Here, we report on the first demonstration of dissipation of fully avalanched post-disruption runaway electron (RE) beams by shattered pellet injection in the DIII-D tokamak. Variation of the injected species shows that dissipation depends strongly on the species mixture, while comparisons with massive gas injection do not show a significant difference between dissipation by pellets or by gas, suggesting that the shattered pellet is rapidly ablated by the relativistic electrons before significant radial penetration into the runaway beam can occur. Pure or dominantly neon injection increases the RE current dissipation through pitch-angle scattering due to collisions with impurity ions. Deuteriummore » injection is observed to have the opposite effect from neon, causing the background thermal plasma to completely recombine, reducing the high-Z impurity content and thus decreasing the dissipation. When injecting mixtures of the two species, deuterium levels as low as ~10% of the total injected atoms are observed to adversely affect the resulting dissipation, suggesting that complete elimination of deuterium from the injection may be important for optimizing RE mitigation schemes.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1432365-dissipation-post-disruption-runaway-electron-plateaus-shattered-pellet-injection-diii','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1432365-dissipation-post-disruption-runaway-electron-plateaus-shattered-pellet-injection-diii"><span>Dissipation of post-disruption runaway electron plateaus by shattered pellet injection in DIII-D</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Shiraki, D.; Commaux, N.; Baylor, L. R.; ...</p> <p>2018-03-07</p> <p>Here, we report on the first demonstration of dissipation of fully avalanched post-disruption runaway electron (RE) beams by shattered pellet injection in the DIII-D tokamak. Variation of the injected species shows that dissipation depends strongly on the species mixture, while comparisons with massive gas injection do not show a significant difference between dissipation by pellets or by gas, suggesting that the shattered pellet is rapidly ablated by the relativistic electrons before significant radial penetration into the runaway beam can occur. Pure or dominantly neon injection increases the RE current dissipation through pitch-angle scattering due to collisions with impurity ions. Deuteriummore » injection is observed to have the opposite effect from neon, causing the background thermal plasma to completely recombine, reducing the high-Z impurity content and thus decreasing the dissipation. When injecting mixtures of the two species, deuterium levels as low as ~10% of the total injected atoms are observed to adversely affect the resulting dissipation, suggesting that complete elimination of deuterium from the injection may be important for optimizing RE mitigation schemes.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2012AGUFM.H44B..05M','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2012AGUFM.H44B..05M"><span>Reactive Tracer Techniques to Quantitatively Monitor Carbon Dioxide Storage in Geologic Formations</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Matter, J. M.; Carson, C.; Stute, M.; Broecker, W. S.</p> <p>2012-12-01</p> <p>Injection of CO2 into geologic storage reservoirs induces fluid-rock reactions that may lead to the mineralization of the injected CO2. The long-term safety of geologic CO2 storage is, therefore, determined by in situ CO2-fluid-rock reactions. Currently existing monitoring and verification techniques for CO2 storage are insufficient to characterize the solubility and reactivity of the injected CO2, and to establish a mass balance of the stored CO2. Dissolved and chemically transformed CO2 thus avoid detection. We developed and are testing a new reactive tracer technique for quantitative monitoring and detection of dissolved and chemically transformed CO2 in geologic storage reservoirs. The technique involves tagging the injected carbon with radiocarbon (14C). Carbon-14 is a naturally occurring radioisotope produced by cosmic radiation and made artificially by 14N neutron capture. The ambient concentration is very low with a 14C/12C ratio of 10-12. The concentration of 14C in deep geologic formations and fossil fuels is at least two orders of magnitude lower. This makes 14C an ideal quantitative tracer for tagging underground injections of anthropogenic CO2. We are testing the feasibility of this tracer technique at the CarbFix pilot injection site in Iceland, where approximately 2,000 tons of CO2 dissolved in water are currently injected into a deep basalt aquifer. The injected CO2 is tagged with 14C by dynamically adding calibrated amounts of H14CO3 solution to the injection stream. The target concentration is 12 Bq/kg of injected water, which results in a 14C activity that is 5 times enriched compared to the 1850 background. In addition to 14C as a reactive tracer, trifluormethylsulphur pentafluoride (SF5CF3) and sulfurhexafluoride (SF6) are used as conservative tracers to monitor the transport of the injected CO2 in the subsurface. Fluid samples are collected for tracer analysis from the injection and monitoring wells on a regular basis. Results show a fast reaction of the injected CO2 with the ambient reservoir fluid and rocks. Mixing and in situ CO2-water-rock reactions are detected by changes in the different tracer ratios. The feasibility of 14C as a reactive tracer for geologic CO2 storage also depends on the analytical technique used to measure 14C activities. Currently, 14C is analyzed using Accelerator Mass Spectrometery (AMS), which is expensive and requires centralized facilities. To enable real time online monitoring and verification, we are developing an alternative detection method for radiocarbon. The IntraCavity OptoGalvanic Spectroscopy (ICOGS) system is using a CO2 laser to detect carbon isotope ratios at environmental levels. Results from our prototype of this bench-top technology demonstrate that an ICOGS system can be used in a continuous mode with analysis times of the order of minutes, and can deliver data of similar quality as AMS.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2013AGUFM.A41L..02C','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2013AGUFM.A41L..02C"><span>Downscaling seasonal to centennial simulations on distributed computing infrastructures using WRF model. The WRF4G project</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Cofino, A. S.; Fernández Quiruelas, V.; Blanco Real, J. C.; García Díez, M.; Fernández, J.</p> <p>2013-12-01</p> <p>Nowadays Grid Computing is powerful computational tool which is ready to be used for scientific community in different areas (such as biomedicine, astrophysics, climate, etc.). However, the use of this distributed computing infrastructures (DCI) is not yet common practice in climate research, and only a few teams and applications in this area take advantage of this infrastructure. Thus, the WRF4G project objective is to popularize the use of this technology in the atmospheric sciences area. In order to achieve this objective, one of the most used applications has been taken (WRF; a limited- area model, successor of the MM5 model), that has a user community formed by more than 8000 researchers worldwide. This community develop its research activity on different areas and could benefit from the advantages of Grid resources (case study simulations, regional hind-cast/forecast, sensitivity studies, etc.). The WRF model is used by many groups, in the climate research community, to carry on downscaling simulations. Therefore this community will also benefit. However, Grid infrastructures have some drawbacks for the execution of applications that make an intensive use of CPU and memory for a long period of time. This makes necessary to develop a specific framework (middleware). This middleware encapsulates the application and provides appropriate services for the monitoring and management of the simulations and the data. Thus,another objective of theWRF4G project consists on the development of a generic adaptation of WRF to DCIs. It should simplify the access to the DCIs for the researchers, and also to free them from the technical and computational aspects of the use of theses DCI. Finally, in order to demonstrate the ability of WRF4G solving actual scientific challenges with interest and relevance on the climate science (implying a high computational cost) we will shown results from different kind of downscaling experiments, like ERA-Interim re-analysis, CMIP5 models, or seasonal. WRF4G is been used to run WRF simulations which are contributing to the CORDEX initiative and others projects like SPECS and EUPORIAS. This work is been partially funded by the European Regional Development Fund (ERDF) and the Spanish National R&D Plan 2008-2011 (CGL2011-28864)</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29475754','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29475754"><span>Antibacterial activity against Streptococcus mutans and diametrical tensile strength of an interim cement modified with zinc oxide nanoparticles and terpenes: An in vitro study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Andrade, Verónica; Martínez, Alejandra; Rojas, Ninón; Bello-Toledo, Helia; Flores, Paulo; Sánchez-Sanhueza, Gabriela; Catalán, Alfonso</p> <p>2018-05-01</p> <p>Interim restorations are occasionally left in the mouth for extended periods and are susceptible to bacterial infiltration. Thus, dental interim cements with antibacterial properties are required. The purpose of this in vitro study was to determine in vitro antibacterial activity against Streptococcus mutans and to compare the diametrical tensile strength (DTSs) of dental interim cement modified with zinc oxide nanoparticles (ZnO-NPs) with that of cement modified with terpenes. Antibacterial properties of ZnO-NPs, terpenes, and dental interim cement modified with ZnO-NPs and cement modified with terpenes against S mutans were tested according to minimum inhibitory concentration (MIC) and direct contact inhibition (DCI). Tensile strength levels were evaluated using DTS. Results were analyzed using the Kolmogorov-Smirnov, ANOVA, and Tamhane tests (α=.05). The MICs of ZnO-NPs and terpenes against S mutans were 61.94 μg/g and 0.25% v/v, respectively. The DCI assay under the cylinders of cement (area of contact with the agar surface) revealed significant bacterial growth inhibition on Temp-Bond NE specimens with ZnO-NPs at MIC of 495.2 μg/g (8× MIC) and with terpenes at MIC 0.999% v/v (4× MIC) (P<.05). The Temp-Bond NE cement cylinder (control group) showed the lowest DTS (1.05 ±0.27 MPa) of all other test groups. In the Zn-NPs group, the greatest increase occurred in the NP8 (8× MIC; 495.2 μg/g) group with a value of 1.50 ±0.23 MPa, a significant increase in DTS compared with the control and terpene groups (P<.05). In the terpene group, the highest increase corresponded to group T2 (2× MIC; 0.4995% v/v) with a value of 1.29 ±0.18 MPa. The addition of terpenes and ZnO-NPs to interim cement showed antibacterial activity when in contact with S. mutans ATCC 25175. Both terpenes and ZnO-NPs antimicrobial agents increased diametral tensile strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016JGRA..12111729H','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016JGRA..12111729H"><span>Contributions of substorm injections to SYM-H depressions in the main phase of storms</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>He, Zhaohai; Dai, Lei; Wang, Chi; Duan, Suping; Zhang, Lingqian; Chen, Tao; Roth, I.</p> <p>2016-12-01</p> <p>Substorm injections bring energetic particles to the inner magnetosphere. But the role of the injected population in building up the storm time ring current is not well understood. By surveying Los Alamos National Laboratory geosynchronous data during 34 storm main phases, we show evidence that at least some substorm injections can contribute to substorm-time scale SYM-H/Dst depressions in the main phase of storms. For event studies, we analyze two typical events in which the main-phase SYM-H index exhibited stepwise depressions that are correlated with particle flux enhancement due to injections and with AL index. A statistical study is performed based on 95 storm time injection events. The flux increases of the injected population (50-400 keV) are found proportional to the sharp SYM-H depressions during the injection interval. By identifying dispersionless and dispersive injection signals, we estimate the azimuthal extent of the substorm injection. Statistical results show that the injection regions of these storm time substorms are characterized with an azimuthal extent larger than 06:00 magnetic local time. These results suggest that at least some substorm injections may mimic the large-scale enhanced convection and contribute to sharp decreases of Dst in the storm main phase.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.dtic.mil/docs/citations/AD0621556','DTIC-ST'); return false;" href="http://www.dtic.mil/docs/citations/AD0621556"><span>A THRESHOLD ANALYSIS OF THE TUNNEL INJECTION LASER.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.dtic.mil/">DTIC Science & Technology</a></p> <p></p> <p></p> <p>A new threshold analysis of the tunnel injection laser is given that differs from previous treatments in that an additional loss mechanism is...a slight increase in the threshold current density of the tunnel laser. For a device one millimeter long composed of GaAs at 77K, the threshold</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29381142','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29381142"><span>Exploring the validity and limitations of the Mott-Gurney law for charge-carrier mobility determination of semiconducting thin-films.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Röhr, Jason A; Moia, Davide; Haque, Saif A; Kirchartz, Thomas; Nelson, Jenny</p> <p>2018-03-14</p> <p>Using drift-diffusion simulations, we investigate the voltage dependence of the dark current in single carrier devices typically used to determine charge-carrier mobilities. For both low and high voltages, the current increases linearly with the applied voltage. Whereas the linear current at low voltages is mainly due to space charge in the middle of the device, the linear current at high voltage is caused by charge-carrier saturation due to a high degree of injection. As a consequence, the current density at these voltages does not follow the classical square law derived by Mott and Gurney, and we show that for trap-free devices, only for intermediate voltages, a space-charge-limited drift current can be observed with a slope that approaches a value of two. We show that, depending on the thickness of the semiconductor layer and the size of the injection barriers, the two linear current-voltage regimes can dominate the whole voltage range, and the intermediate Mott-Gurney regime can shrink or disappear. In this case, which will especially occur for thicknesses and injection barriers typical of single-carrier devices used to probe organic semiconductors, a meaningful analysis using the Mott-Gurney law will become unachievable, because a square-law fit can no longer be achieved, resulting in the mobility being substantially underestimated. General criteria for when to expect deviations from the Mott-Gurney law when used for analysis of intrinsic semiconductors are discussed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018JPCM...30j5901R','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018JPCM...30j5901R"><span>Exploring the validity and limitations of the Mott-Gurney law for charge-carrier mobility determination of semiconducting thin-films</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Röhr, Jason A.; Moia, Davide; Haque, Saif A.; Kirchartz, Thomas; Nelson, Jenny</p> <p>2018-03-01</p> <p>Using drift-diffusion simulations, we investigate the voltage dependence of the dark current in single carrier devices typically used to determine charge-carrier mobilities. For both low and high voltages, the current increases linearly with the applied voltage. Whereas the linear current at low voltages is mainly due to space charge in the middle of the device, the linear current at high voltage is caused by charge-carrier saturation due to a high degree of injection. As a consequence, the current density at these voltages does not follow the classical square law derived by Mott and Gurney, and we show that for trap-free devices, only for intermediate voltages, a space-charge-limited drift current can be observed with a slope that approaches a value of two. We show that, depending on the thickness of the semiconductor layer and the size of the injection barriers, the two linear current-voltage regimes can dominate the whole voltage range, and the intermediate Mott-Gurney regime can shrink or disappear. In this case, which will especially occur for thicknesses and injection barriers typical of single-carrier devices used to probe organic semiconductors, a meaningful analysis using the Mott-Gurney law will become unachievable, because a square-law fit can no longer be achieved, resulting in the mobility being substantially underestimated. General criteria for when to expect deviations from the Mott-Gurney law when used for analysis of intrinsic semiconductors are discussed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26061200','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26061200"><span>Profiling of Current Transients in Capacitor Type Diamond Sensors.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Gaubas, Eugenijus; Ceponis, Tomas; Meskauskaite, Dovile; Kazuchits, Nikolai</p> <p>2015-06-08</p> <p>The operational characteristics of capacitor-type detectors based on HPHT and CVD diamond have been investigated using perpendicular and parallel injection of carrier domain regimes. Simulations of the drift-diffusion current transients have been implemented by using dynamic models based on Shockley-Ramo's theorem, under injection of localized surface domains and of bulk charge carriers. The bipolar drift-diffusion regimes have been analyzed for the photo-induced bulk domain (packet) of excess carriers. The surface charge formation and polarization effects dependent on detector biasing voltage have been revealed. The screening effects ascribed to surface charge and to dynamics of extraction of the injected bulk excess carrier domain have been separated and explained. The parameters of drift mobility of the electrons μ(e) = 4000 cm2/Vs and holes μ(h) = 3800 cm2/Vs have been evaluated for CVD diamond using the perpendicular profiling of currents. The coefficient of carrier ambipolar diffusion D(a) = 97 cm2/s and the carrier recombination lifetime τ(R,CVD) ≌ 110 ns in CVD diamond were extracted by combining analysis of the transients of the sensor current and the microwave probed photoconductivity. The carrier trapping with inherent lifetime τR,HPHT ≌ 2 ns prevails in HPHT diamond.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22591553-low-absorption-loss-algan-superlattice-cladding-layer-current-injection-deep-ultraviolet-laser-diodes','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22591553-low-absorption-loss-algan-superlattice-cladding-layer-current-injection-deep-ultraviolet-laser-diodes"><span>Low absorption loss p-AlGaN superlattice cladding layer for current-injection deep ultraviolet laser diodes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Martens, M.; Kuhn, C.; Ziffer, E.</p> <p>2016-04-11</p> <p>Current injection into AlGaN-based laser diode structures with high aluminum mole fractions for deep ultraviolet emission is investigated. The electrical characteristics of laser diode structures with different p-AlGaN short period superlattice (SPSL) cladding layers with various aluminum mole fractions are compared. The heterostructures contain all elements that are needed for a current-injection laser diode including cladding and waveguide layers as well as an AlGaN quantum well active region emitting near 270 nm. We found that with increasing aluminum content in the p-AlGaN cladding, the diode turn-on voltage increases, while the series resistance slightly decreases. By introducing an SPSL instead of bulkmore » layers, the operating voltage is significantly reduced. A gain guided broad area laser diode structure with transparent p-Al{sub 0.70}Ga{sub 0.30}N waveguide layers and a transparent p-cladding with an average aluminum content of 81% was designed for strong confinement of the transverse optical mode and low optical losses. Using an optimized SPSL, this diode could sustain current densities of more than 4.5 kA/cm{sup 2}.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22591708-current-gain-above-sub-base-iii-nitride-tunneling-hot-electron-transistors-gan-aln-emitter','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22591708-current-gain-above-sub-base-iii-nitride-tunneling-hot-electron-transistors-gan-aln-emitter"><span>Current gain above 10 in sub-10 nm base III-Nitride tunneling hot electron transistors with GaN/AlN emitter</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Yang, Zhichao, E-mail: zcyang.phys@gmail.com; Zhang, Yuewei; Krishnamoorthy, Sriram</p> <p></p> <p>We report on a tunneling hot electron transistor amplifier with common-emitter current gain greater than 10 at a collector current density in excess of 40 kA/cm{sup 2}. The use of a wide-bandgap GaN/AlN (111 nm/2.5 nm) emitter was found to greatly improve injection efficiency of the emitter and reduce cold electron leakage. With an ultra-thin (8 nm) base, 93% of the injected hot electrons were collected, enabling a common-emitter current gain up to 14.5. This work improves understanding of the quasi-ballistic hot electron transport and may impact the development of high speed devices based on unipolar hot electron transport.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017APExp..10d3002K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017APExp..10d3002K"><span>Energy-efficient writing scheme for magnetic domain-wall motion memory</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Kim, Kab-Jin; Yoshimura, Yoko; Ham, Woo Seung; Ernst, Rick; Hirata, Yuushou; Li, Tian; Kim, Sanghoon; Moriyama, Takahiro; Nakatani, Yoshinobu; Ono, Teruo</p> <p>2017-04-01</p> <p>We present an energy-efficient magnetic domain-writing scheme for domain wall (DW) motion-based memory devices. A cross-shaped nanowire is employed to inject a domain into the nanowire through current-induced DW propagation. The energy required for injecting the magnetic domain is more than one order of magnitude lower than that for the conventional field-based writing scheme. The proposed scheme is beneficial for device miniaturization because the threshold current for DW propagation scales with the device size, which cannot be achieved in the conventional field-based technique.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2014JPhCS.541a2056K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2014JPhCS.541a2056K"><span>The analytical approach to optimization of active region structure of quantum dot laser</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Korenev, V. V.; Savelyev, A. V.; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V.</p> <p>2014-10-01</p> <p>Using the analytical approach introduced in our previous papers we analyse the possibilities of optimization of size and structure of active region of semiconductor quantum dot lasers emitting via ground-state optical transitions. It is shown that there are optimal length' dispersion and number of QD layers in laser active region which allow one to obtain lasing spectrum of a given width at minimum injection current. Laser efficiency corresponding to the injection current optimized by the cavity length is practically equal to its maximum value.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2015JPhCS.643a2041K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2015JPhCS.643a2041K"><span>Injection current minimization of InAs/InGaAs quantum dot laser by optimization of its active region and reflectivity of laser cavity edges</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Korenev, V. V.; Savelyev, A. V.; Zhukov, A. E.; Maximov, M. V.</p> <p>2015-11-01</p> <p>The ways to optimize key parameters of active region and edge reflectivity of edge- emitting semiconductor quantum dot laser are provided. It is shown that in the case of optimal cavity length and sufficiently large dispersion lasing spectrum of a given width can be obtained at injection current up to an order of magnitude lower in comparison to non-optimized sample. The influence of internal loss and edge reflection is also studied in details.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/20935754','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/20935754"><span>Bistable optical devices with laser diodes coupled to absorbers of narrow spectral bandwidth.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Maeda, Y</p> <p>1994-06-20</p> <p>An optical signal inverter was demonstrated with a combination of the following two effects: One is the decrease of the transmission of an Er-doped YAG crystal with increasing red shift of a laser diode resulting from an increase in the injection current, and the other is a negative nonlinear absorption in which the transmission decreases inversely with increasing laser intensity. Because a hysteresis characteristic exists in the relationship between the wavelength and the injection current of the laser diode, an optical bistability was observed in this system.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_25 --> <div class="footer-extlink text-muted" style="margin-bottom:1rem; text-align:center;">Some links on this page may take you to non-federal websites. Their policies may differ from this site.</div> </div><!-- container --> <a id="backToTop" href="#top"> Top </a> <footer> <nav> <ul class="links"> <li><a href="/sitemap.html">Site Map</a></li> <li><a href="/website-policies.html">Website Policies</a></li> <li><a href="https://www.energy.gov/vulnerability-disclosure-policy" target="_blank">Vulnerability Disclosure Program</a></li> <li><a href="/contact.html">Contact Us</a></li> </ul> </nav> </footer> <script type="text/javascript"><!-- // var lastDiv = ""; function showDiv(divName) { // hide last div if (lastDiv) { document.getElementById(lastDiv).className = "hiddenDiv"; } //if value of the box is not nothing and an object with that name exists, then change the class if (divName && document.getElementById(divName)) { document.getElementById(divName).className = "visibleDiv"; lastDiv = divName; } } //--> </script> <script> /** * Function that tracks a click on an outbound link in Google Analytics. * This function takes a valid URL string as an argument, and uses that URL string * as the event label. */ var trackOutboundLink = function(url,collectionCode) { try { h = window.open(url); setTimeout(function() { ga('send', 'event', 'topic-page-click-through', collectionCode, url); }, 1000); } catch(err){} }; </script> <!-- Google Analytics --> <script> (function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){ (i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o), m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m) })(window,document,'script','//www.google-analytics.com/analytics.js','ga'); ga('create', 'UA-1122789-34', 'auto'); ga('send', 'pageview'); </script> <!-- End Google Analytics --> <script> showDiv('page_1') </script> </body> </html>