Sample records for current monitoring methods

  1. On-line tool breakage monitoring of vibration tapping using spindle motor current

    NASA Astrophysics Data System (ADS)

    Li, Guangjun; Lu, Huimin; Liu, Gang

    2008-10-01

    Input current of driving motor has been employed successfully as monitoring the cutting state in manufacturing processes for more than a decade. In vibration tapping, however, the method of on-line monitoring motor electric current has not been reported. In this paper, a tap failure prediction method is proposed to monitor the vibration tapping process using the electrical current signal of the spindle motor. The process of vibration tapping is firstly described. Then the relationship between the torque of vibration tapping and the electric current of motor is investigated by theoretic deducing and experimental measurement. According to those results, a monitoring method of tool's breakage is proposed through monitoring the ratio of the current amplitudes during adjacent vibration tapping periods. Finally, a low frequency vibration tapping system with motor current monitoring is built up using a servo motor B-106B and its driver CR06. The proposed method has been demonstrated with experiment data of vibration tapping in titanic alloys. The result of experiments shows that the method, which can avoid the tool breakage and giving a few error alarms when the threshold of amplitude ratio is 1.2 and there is at least 2 times overrun among 50 adjacent periods, is feasible for tool breakage monitoring in the process of vibration tapping small thread holes.

  2. Motor monitoring method and apparatus using high frequency current components

    DOEpatents

    Casada, D.A.

    1996-05-21

    A motor current analysis method and apparatus for monitoring electrical-motor-driven devices are disclosed. The method and apparatus utilize high frequency portions of the motor current spectra to evaluate the condition of the electric motor and the device driven by the electric motor. The motor current signal produced as a result of an electric motor is monitored and the low frequency components of the signal are removed by a high-pass filter. The signal is then analyzed to determine the condition of the electrical motor and the driven device. 16 figs.

  3. Motor monitoring method and apparatus using high frequency current components

    DOEpatents

    Casada, Donald A.

    1996-01-01

    A motor current analysis method and apparatus for monitoring electrical-motor-driven devices. The method and apparatus utilize high frequency portions of the motor current spectra to evaluate the condition of the electric motor and the device driven by the electric motor. The motor current signal produced as a result of an electric motor is monitored and the low frequency components of the signal are removed by a high-pass filter. The signal is then analyzed to determine the condition of the electrical motor and the driven device.

  4. Monitoring method and apparatus using high-frequency carrier

    DOEpatents

    Haynes, Howard D.

    1996-01-01

    A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device.

  5. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    NASA Astrophysics Data System (ADS)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  6. Monitoring method and apparatus using high-frequency carrier

    DOEpatents

    Haynes, H.D.

    1996-04-30

    A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device. 6 figs.

  7. Intracranial Pressure Monitoring—Review and Avenues for Development

    PubMed Central

    Dolmans, Rianne G. F.

    2018-01-01

    Intracranial pressure (ICP) monitoring is a staple of neurocritical care. The most commonly used current methods of monitoring in the acute setting include fluid-based systems, implantable transducers and Doppler ultrasonography. It is well established that management of elevated ICP is critical for clinical outcomes. However, numerous studies show that current methods of ICP monitoring cannot reliably define the limit of the brain’s intrinsic compensatory capacity to manage increases in pressure, which would allow for proactive ICP management. Current work in the field hopes to address this gap by harnessing live-streaming ICP pressure-wave data and a multimodal integration with other physiologic measures. Additionally, there is continued development of non-invasive ICP monitoring methods for use in specific clinical scenarios. PMID:29401746

  8. Motor current signature analysis for gearbox condition monitoring under transient speeds using wavelet analysis and dual-level time synchronous averaging

    NASA Astrophysics Data System (ADS)

    Bravo-Imaz, Inaki; Davari Ardakani, Hossein; Liu, Zongchang; García-Arribas, Alfredo; Arnaiz, Aitor; Lee, Jay

    2017-09-01

    This paper focuses on analyzing motor current signature for fault diagnosis of gearboxes operating under transient speed regimes. Two different strategies are evaluated, extensively tested and compared to analyze the motor current signature in order to implement a condition monitoring system for gearboxes in industrial machinery. A specially designed test bench is used, thoroughly monitored to fully characterize the experiments, in which gears in different health status are tested. The measured signals are analyzed using discrete wavelet decomposition, in different decomposition levels using a range of mother wavelets. Moreover, a dual-level time synchronous averaging analysis is performed on the same signal to compare the performance of the two methods. From both analyses, the relevant features of the signals are extracted and cataloged using a self-organizing map, which allows for an easy detection and classification of the diverse health states of the gears. The results demonstrate the effectiveness of both methods for diagnosing gearbox faults. A slightly better performance was observed for dual-level time synchronous averaging method. Based on the obtained results, the proposed methods can used as effective and reliable condition monitoring procedures for gearbox condition monitoring using only motor current signature.

  9. Advanced aircraft service life monitoring method via flight-by-flight load spectra

    NASA Astrophysics Data System (ADS)

    Lee, Hongchul

    This research is an effort to understand current method and to propose an advanced method for Damage Tolerance Analysis (DTA) for the purpose of monitoring the aircraft service life. As one of tasks in the DTA, the current indirect Individual Aircraft Tracking (IAT) method for the F-16C/D Block 32 does not properly represent changes in flight usage severity affecting structural fatigue life. Therefore, an advanced aircraft service life monitoring method based on flight-by-flight load spectra is proposed and recommended for IAT program to track consumed fatigue life as an alternative to the current method which is based on the crack severity index (CSI) value. Damage Tolerance is one of aircraft design philosophies to ensure that aging aircrafts satisfy structural reliability in terms of fatigue failures throughout their service periods. IAT program, one of the most important tasks of DTA, is able to track potential structural crack growth at critical areas in the major airframe structural components of individual aircraft. The F-16C/D aircraft is equipped with a flight data recorder to monitor flight usage and provide the data to support structural load analysis. However, limited memory of flight data recorder allows user to monitor individual aircraft fatigue usage in terms of only the vertical inertia (NzW) data for calculating Crack Severity Index (CSI) value which defines the relative maneuver severity. Current IAT method for the F-16C/D Block 32 based on CSI value calculated from NzW is shown to be not accurate enough to monitor individual aircraft fatigue usage due to several problems. The proposed advanced aircraft service life monitoring method based on flight-by-flight load spectra is recommended as an improved method for the F-16C/D Block 32 aircraft. Flight-by-flight load spectra was generated from downloaded Crash Survival Flight Data Recorder (CSFDR) data by calculating loads for each time hack in selected flight data utilizing loads equations. From the comparison of interpolated fatigue life using CSI value and fatigue test results, it is obvious that proposed advanced IAT method via flight-by-flight load spectra is more reliable and accurate than current IAT method. Therefore, the advanced aircraft service life monitoring method based on flight-by-flight load spectra not only monitors the individual aircraft consumed fatigue life for inspection but also ensures the structural reliability of aging aircrafts throughout their service periods.

  10. Measuring and monitoring KIPT Neutron Source Facility Reactivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Yan; Gohar, Yousry; Zhong, Zhaopeng

    2015-08-01

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has k eff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine themore » reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.« less

  11. Noninvasive Intracranial Pressure Monitoring for Severe Traumatic Brain Injury in Children: A Concise Update on Current Methods.

    PubMed

    Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad; Notarianni, Christina; Nanda, Anil

    2018-06-01

    Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Global Monitoring of Water Supply and Sanitation: History, Methods and Future Challenges

    PubMed Central

    Bartram, Jamie; Brocklehurst, Clarissa; Fisher, Michael B.; Luyendijk, Rolf; Hossain, Rifat; Wardlaw, Tessa; Gordon, Bruce

    2014-01-01

    International monitoring of drinking water and sanitation shapes awareness of countries’ needs and informs policy, implementation and research efforts to extend and improve services. The Millennium Development Goals established global targets for drinking water and sanitation access; progress towards these targets, facilitated by international monitoring, has contributed to reducing the global disease burden and increasing quality of life. The experiences of the MDG period generated important lessons about the strengths and limitations of current approaches to defining and monitoring access to drinking water and sanitation. The methods by which the Joint Monitoring Programme (JMP) of WHO and UNICEF tracks access and progress are based on analysis of data from household surveys and linear regression modelling of these results over time. These methods provide nationally-representative and internationally-comparable insights into the drinking water and sanitation facilities used by populations worldwide, but also have substantial limitations: current methods do not address water quality, equity of access, or extra-household services. Improved statistical methods are needed to better model temporal trends. This article describes and critically reviews JMP methods in detail for the first time. It also explores the impact of, and future directions for, international monitoring of drinking water and sanitation. PMID:25116635

  13. Availability and performance of image/video-based vital signs monitoring methods: a systematic review protocol.

    PubMed

    Harford, Mirae; Catherall, Jacqueline; Gerry, Stephen; Young, Duncan; Watkinson, Peter

    2017-10-25

    For many vital signs, monitoring methods require contact with the patient and/or are invasive in nature. There is increasing interest in developing still and video image-guided monitoring methods that are non-contact and non-invasive. We will undertake a systematic review of still and video image-based monitoring methods. We will perform searches in multiple databases which include MEDLINE, Embase, CINAHL, Cochrane library, IEEE Xplore and ACM Digital Library. We will use OpenGrey and Google searches to access unpublished or commercial data. We will not use language or publication date restrictions. The primary goal is to summarise current image-based vital signs monitoring methods, limited to heart rate, respiratory rate, oxygen saturations and blood pressure. Of particular interest will be the effectiveness of image-based methods compared to reference devices. Other outcomes of interest include the quality of the method comparison studies with respect to published reporting guidelines, any limitations of non-contact non-invasive technology and application in different populations. To the best of our knowledge, this is the first systematic review of image-based non-contact methods of vital signs monitoring. Synthesis of currently available technology will facilitate future research in this highly topical area. PROSPERO CRD42016029167.

  14. An imbalance fault detection method based on data normalization and EMD for marine current turbines.

    PubMed

    Zhang, Milu; Wang, Tianzhen; Tang, Tianhao; Benbouzid, Mohamed; Diallo, Demba

    2017-05-01

    This paper proposes an imbalance fault detection method based on data normalization and Empirical Mode Decomposition (EMD) for variable speed direct-drive Marine Current Turbine (MCT) system. The method is based on the MCT stator current under the condition of wave and turbulence. The goal of this method is to extract blade imbalance fault feature, which is concealed by the supply frequency and the environment noise. First, a Generalized Likelihood Ratio Test (GLRT) detector is developed and the monitoring variable is selected by analyzing the relationship between the variables. Then, the selected monitoring variable is converted into a time series through data normalization, which makes the imbalance fault characteristic frequency into a constant. At the end, the monitoring variable is filtered out by EMD method to eliminate the effect of turbulence. The experiments show that the proposed method is robust against turbulence through comparing the different fault severities and the different turbulence intensities. Comparison with other methods, the experimental results indicate the feasibility and efficacy of the proposed method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Inflight Microbial Monitoring - An Alternative Method to Culture Based Detection Currently Used on the International Space Station

    NASA Technical Reports Server (NTRS)

    Khodadad, Christina L.; Birmele, Michele N.; Hummerick, Mary E.; Roman, Monsi; Smith, David J.

    2015-01-01

    Microorganisms including potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Current microbial monitoring methods require enrichment of microorganisms and a 48-hour incubation time resulting in an increase in microbial load, detecting a limited number of unidentified microorganisms. An expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted.

  16. Education for worksite monitors of impaired nurses.

    PubMed

    Young, Linda J

    2008-01-01

    Boards of nursing sponsor programs, including those for alternatives to discipline, for recovering nurses. These programs rely on worksite monitors who are oftentimes other nurses or supervisors of nurses, to work with recovering nurses when they return to practice. The skills of these monitors vary with respect to understanding the monitor role and recognizing traits in chemical dependency and relapse. To determine the degree of content value and the best teaching method for monitors to learn program content, 17 currently active worksite monitors participated in a study to evaluate content value to 2 groups, new and experienced monitors, and to select the best method to teach 4 content topics. Results showed that current content was valued without necessary additions and that group instruction in urban areas was preferred over one-to-one instruction. Implementation of study outcomes yielded that issues of confidentiality made group instruction unsatisfactory.

  17. A Method of High Throughput Monitoring Crop Physiology Using Chlorophyll Fluorescence and Multispectral Imaging.

    PubMed

    Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu

    2018-01-01

    We present a high throughput crop physiology condition monitoring system and corresponding monitoring method. The monitoring system can perform large-area chlorophyll fluorescence imaging and multispectral imaging. The monitoring method can determine the crop current condition continuously and non-destructively. We choose chlorophyll fluorescence parameters and relative reflectance of multispectral as the indicators of crop physiological status. Using tomato as experiment subject, the typical crop physiological stress, such as drought, nutrition deficiency and plant disease can be distinguished by the monitoring method. Furthermore, we have studied the correlation between the physiological indicators and the degree of stress. Besides realizing the continuous monitoring of crop physiology, the monitoring system and method provide the possibility of machine automatic diagnosis of the plant physiology. Highlights: A newly designed high throughput crop physiology monitoring system and the corresponding monitoring method are described in this study. Different types of stress can induce distinct fluorescence and spectral characteristics, which can be used to evaluate the physiological status of plants.

  18. Monitoring apparatus and method for battery power supply

    DOEpatents

    Martin, Harry L.; Goodson, Raymond E.

    1983-01-01

    A monitoring apparatus and method are disclosed for monitoring and/or indicating energy that a battery power source has then remaining and/or can deliver for utilization purposes as, for example, to an electric vehicle. A battery mathematical model forms the basis for monitoring with a capacity prediction determined from measurement of the discharge current rate and stored battery parameters. The predicted capacity is used to provide a state-of-charge indication. Self-calibration over the life of the battery power supply is enacted through use of a feedback voltage based upon the difference between predicted and measured voltages to correct the battery mathematical model. Through use of a microprocessor with central information storage of temperature, current and voltage, system behavior is monitored, and system flexibility is enhanced.

  19. The development of control and monitoring system on marine current renewable energy Case study: strait of Toyapakeh - Nusa Penida, Bali

    NASA Astrophysics Data System (ADS)

    Arief, I. S.; Suherman, I. H.; Wardani, A. Y.; Baidowi, A.

    2017-05-01

    Control and monitoring system is a continuous process of securing the asset in the Marine Current Renewable Energy. A control and monitoring system is existed each critical components which is embedded in Failure Mode Effect Analysis (FMEA) method. As the result, the process in this paper developed through a matrix sensor. The matrix correlated to critical components and monitoring system which supported by sensors to conduct decision-making.

  20. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheat, Jr., Robert Mitchell; Dalmas, Dale A.; Dale, Gregory E.

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have beenmore » identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.« less

  1. Monitoring tooth profile faults in epicyclic gearboxes using synchronously averaged motor currents: Mathematical modeling and experimental validation

    NASA Astrophysics Data System (ADS)

    Ottewill, J. R.; Ruszczyk, A.; Broda, D.

    2017-02-01

    Time-varying transmission paths and inaccessibility can increase the difficulty in both acquiring and processing vibration signals for the purpose of monitoring epicyclic gearboxes. Recent work has shown that the synchronous signal averaging approach may be applied to measured motor currents in order to diagnose tooth faults in parallel shaft gearboxes. In this paper we further develop the approach, so that it may also be applied to monitor tooth faults in epicyclic gearboxes. A low-degree-of-freedom model of an epicyclic gearbox which incorporates the possibility of simulating tooth faults, as well as any subsequent tooth contact loss due to these faults, is introduced. By combining this model with a simple space-phasor model of an induction motor it is possible to show that, in theory, tooth faults in epicyclic gearboxes may be identified from motor currents. Applying the synchronous averaging approach to experimentally recorded motor currents and angular displacements recorded from a shaft mounted encoder, validate this finding. Comparison between experiments and theory highlight the influence of operating conditions, backlash and shaft couplings on the transient response excited in the currents by the tooth fault. The results obtained suggest that the method may be a viable alternative or complement to more traditional methods for monitoring gearboxes. However, general observations also indicate that further investigations into the sensitivity and robustness of the method would be beneficial.

  2. Progress Toward Accurate Measurements of Power Consumptions of DBD Plasma Actuators

    NASA Technical Reports Server (NTRS)

    Ashpis, David E.; Laun, Matthew C.; Griebeler, Elmer L.

    2012-01-01

    The accurate measurement of power consumption by Dielectric Barrier Discharge (DBD) plasma actuators is a challenge due to the characteristics of the actuator current signal. Micro-discharges generate high-amplitude, high-frequency current spike transients superimposed on a low-amplitude, low-frequency current. We have used a high-speed digital oscilloscope to measure the actuator power consumption using the Shunt Resistor method and the Monitor Capacitor method. The measurements were performed simultaneously and compared to each other in a time-accurate manner. It was found that low signal-to-noise ratios of the oscilloscopes used, in combination with the high dynamic range of the current spikes, make the Shunt Resistor method inaccurate. An innovative, nonlinear signal compression circuit was applied to the actuator current signal and yielded excellent agreement between the two methods. The paper describes the issues and challenges associated with performing accurate power measurements. It provides insights into the two methods including new insight into the Lissajous curve of the Monitor Capacitor method. Extension to a broad range of parameters and further development of the compression hardware will be performed in future work.

  3. Fuel cell stack monitoring and system control

    DOEpatents

    Keskula, Donald H.; Doan, Tien M.; Clingerman, Bruce J.

    2004-02-17

    A control method for monitoring a fuel cell stack in a fuel cell system in which the actual voltage and actual current from the fuel cell stack are monitored. A preestablished relationship between voltage and current over the operating range of the fuel cell is established. A variance value between the actual measured voltage and the expected voltage magnitude for a given actual measured current is calculated and compared with a predetermined allowable variance. An output is generated if the calculated variance value exceeds the predetermined variance. The predetermined voltage-current for the fuel cell is symbolized as a polarization curve at given operating conditions of the fuel cell.

  4. Systems and methods of monitoring acoustic pressure to detect a flame condition in a gas turbine

    DOEpatents

    Ziminsky, Willy Steve [Simpsonville, SC; Krull, Anthony Wayne [Anderson, SC; Healy, Timothy Andrew , Yilmaz, Ertan

    2011-05-17

    A method may detect a flashback condition in a fuel nozzle of a combustor. The method may include obtaining a current acoustic pressure signal from the combustor, analyzing the current acoustic pressure signal to determine current operating frequency information for the combustor, and indicating that the flashback condition exists based at least in part on the current operating frequency information.

  5. GROUND WATER MONITORING AND SAMPLING: MULTI-LEVEL VERSUS TRADITIONAL METHODS WHATS WHAT?

    EPA Science Inventory

    After years of research and many publications, the question still remains: What is the best method to collect representative ground water samples from monitoring wells? Numerous systems and devices are currently available for obtaining both multi-level samples as well as traditi...

  6. Fuel cell stack monitoring and system control

    DOEpatents

    Keskula, Donald H.; Doan, Tien M.; Clingerman, Bruce J.

    2005-01-25

    A control method for monitoring a fuel cell stack in a fuel cell system in which the actual voltage and actual current from the fuel cell stack are monitored. A preestablished relationship between voltage and current over the operating range of the fuel cell is established. A variance value between the actual measured voltage and the expected voltage magnitude for a given actual measured current is calculated and compared with a predetermined allowable variance. An output is generated if the calculated variance value exceeds the predetermined variance. The predetermined voltage-current for the fuel cell is symbolized as a polarization curve at given operating conditions of the fuel cell. Other polarization curves may be generated and used for fuel cell stack monitoring based on different operating pressures, temperatures, hydrogen quantities.

  7. Migration monitoring with automated technology

    Treesearch

    Rhonda L. Millikin

    2005-01-01

    Automated technology can supplement ground-based methods of migration monitoring by providing: (1) unbiased and automated sampling; (2) independent validation of current methods; (3) a larger sample area for landscape-level analysis of habitat selection for stopover, and (4) an opportunity to study flight behavior. In particular, radar-acoustic sensor fusion can...

  8. Using nocturnal cold air drainage flow to monitor ecosystem processes in complex terrain

    Treesearch

    Thomas G. Pypker; Michael H. Unsworth; Alan C. Mix; William Rugh; Troy Ocheltree; Karrin Alstad; Barbara J. Bond

    2007-01-01

    This paper presents initial investigations of a new approach to monitor ecosystem processes in complex terrain on large scales. Metabolic processes in mountainous ecosystems are poorly represented in current ecosystem monitoring campaigns because the methods used for monitoring metabolism at the ecosystem scale (e.g., eddy covariance) require flat study sites. Our goal...

  9. Current density imaging sequence for monitoring current distribution during delivery of electric pulses in irreversible electroporation.

    PubMed

    Serša, Igor; Kranjc, Matej; Miklavčič, Damijan

    2015-01-01

    Electroporation is gaining its importance in everyday clinical practice of cancer treatment. For its success it is extremely important that coverage of the target tissue, i.e. treated tumor, with electric field is within the specified range. Therefore, an efficient tool for the electric field monitoring in the tumor during delivery of electroporation pulses is needed. The electric field can be reconstructed by the magnetic resonance electric impedance tomography method from current density distribution data. In this study, the use of current density imaging with MRI for monitoring current density distribution during delivery of irreversible electroporation pulses was demonstrated. Using a modified single-shot RARE sequence, where four 3000 V and 100 μs long pulses were included at the start, current distribution between a pair of electrodes inserted in a liver tissue sample was imaged. Two repetitions of the sequence with phases of refocusing radiofrequency pulses 90° apart were needed to acquire one current density image. For each sample in total 45 current density images were acquired to follow a standard protocol for irreversible electroporation where 90 electric pulses are delivered at 1 Hz. Acquired current density images showed that the current density in the middle of the sample increased from first to last electric pulses by 60%, i.e. from 8 kA/m2 to 13 kA/m2 and that direction of the current path did not change with repeated electric pulses significantly. The presented single-shot RARE-based current density imaging sequence was used successfully to image current distribution during delivery of short high-voltage electric pulses. The method has a potential to enable monitoring of tumor coverage by electric field during irreversible electroporation tissue ablation.

  10. Supermarket sales data: feasibility and applicability in population food and nutrition monitoring.

    PubMed

    Tin, Sandar Tin; Mhurchu, Cliona Ni; Bullen, Chris

    2007-01-01

    Population food and nutrition monitoring plays a critical role in understanding suboptimal nutrition at the population level, yet current monitoring methods such as national surveys are not practical to undertake on a continuous basis. Supermarket sales data potentially address this gap by providing detailed, timely, and inexpensive monitoring data for informing policies and anticipating trends. This paper reviews 22 studies that used supermarket sales data to examine food purchasing patterns. Despite some methodological limitations, feasibility studies showed promising results. The potential and limitations of using supermarket sales data to supplement food and nutrition monitoring methods are discussed.

  11. Effect-Based Screening Methods for Water Quality Characterization Will Augment Conventional Analyte-by-Analyte Chemical Methods in Research As Well As Regulatory Monitoring

    EPA Science Inventory

    Conventional approaches to water quality characterization can provide data on individual chemical components of each water sample. This analyte-by-analyte approach currently serves many useful research and compliance monitoring needs. However these approaches, which require a ...

  12. 76 FR 13969 - Notice of Request for Approval of an Information Collection; National Animal Health Monitoring...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-15

    ... support the research and development phase of surveys entitled National Animal Health Monitoring System... commodity surveys; Understand current knowledge gaps in the industry; Determine the proper scope of future... industry being surveyed and the best method to contact respondents, one or more of these methods may be...

  13. Near Real-Time Monitoring of Forest Disturbance: A Multi-Sensor Remote Sensing Approach and Assessment Framework

    NASA Astrophysics Data System (ADS)

    Tang, Xiaojing

    Fast and accurate monitoring of tropical forest disturbance is essential for understanding current patterns of deforestation as well as helping eliminate illegal logging. This dissertation explores the use of data from different satellites for near real-time monitoring of forest disturbance in tropical forests, including: development of new monitoring methods; development of new assessment methods; and assessment of the performance and operational readiness of existing methods. Current methods for accuracy assessment of remote sensing products do not address the priority of near real-time monitoring of detecting disturbance events as early as possible. I introduce a new assessment framework for near real-time products that focuses on the timing and the minimum detectable size of disturbance events. The new framework reveals the relationship between change detection accuracy and the time needed to identify events. In regions that are frequently cloudy, near real-time monitoring using data from a single sensor is difficult. This study extends the work by Xin et al. (2013) and develops a new time series method (Fusion2) based on fusion of Landsat and MODIS (Moderate Resolution Imaging Spectroradiometer) data. Results of three test sites in the Amazon Basin show that Fusion2 can detect 44.4% of the forest disturbance within 13 clear observations (82 days) after the initial disturbance. The smallest event detected by Fusion2 is 6.5 ha. Also, Fusion2 detects disturbance faster and has less commission error than more conventional methods. In a comparison of coarse resolution sensors, MODIS Terra and Aqua combined provides faster and more accurate detection of disturbance events than VIIRS (Visible Infrared Imaging Radiometer Suite) and MODIS single sensor data. The performance of near real-time monitoring using VIIRS is slightly worse than MODIS Terra but significantly better than MODIS Aqua. New monitoring methods developed in this dissertation provide forest protection organizations the capacity to monitor illegal logging events promptly. In the future, combining two Landsat and two Sentinel-2 satellites will provide global coverage at 30 m resolution every 4 days, and routine monitoring may be possible at high resolution. The methods and assessment framework developed in this dissertation are adaptable to newly available datasets.

  14. 50 CFR 218.24 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... experience collecting behavioral data. (iii) MMOs shall not be placed aboard Navy platforms for every Navy..., Navy R&D, and current science to use for potential modification of mitigation or monitoring methods. (3...

  15. 50 CFR 218.24 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... experience collecting behavioral data. (iii) MMOs shall not be placed aboard Navy platforms for every Navy..., Navy R&D, and current science to use for potential modification of mitigation or monitoring methods. (3...

  16. Evolution of monitoring for Giardia and Cryptosporidium in water.

    PubMed

    Efstratiou, Artemis; Ongerth, Jerry; Karanis, Panagiotis

    2017-10-15

    This review describes the evolution of monitoring methodology for Cryptosporidium and Giardia in water since the 1970's. Methods in current use for Giardia and Cryptosporidium in water are highlighted, though attention is given to all available published methods by country and continent. The review is intended to stimulate research leading to future improvements and further developments in monitoring methodology for Giardia, Cryptosporidium and other waterborne protozoan parasites in water. Copyright © 2017. Published by Elsevier Ltd.

  17. Current measurement apparatus

    DOEpatents

    Umans, Stephen D.

    2008-11-11

    Apparatus and methods are provided for a system for measurement of a current in a conductor such that the conductor current may be momentarily directed to a current measurement element in order to maintain proper current without significantly increasing an amount of power dissipation attributable to the current measurement element or adding resistance to assist in current measurement. The apparatus and methods described herein are useful in superconducting circuits where it is necessary to monitor current carried by the superconducting elements while minimizing the effects of power dissipation attributable to the current measurement element.

  18. Policies and practices of beach monitoring in the Great Lakes, USA: a critical review

    USGS Publications Warehouse

    Nevers, Meredith B.; Whitman, Richard L.

    2010-01-01

    Beaches throughout the Great Lakes are monitored for fecal indicator bacteria (typically Escherichia coli) in order to protect the public from potential sewage contamination. Currently, there is no universal standard for sample collection and analysis or results interpretation. Monitoring policies are developed by individual beach management jurisdictions, and applications are highly variable across and within lakes, states, and provinces. Extensive research has demonstrated that sampling decisions for time, depth, number of replicates, frequency of sampling, and laboratory analysis all influence the results outcome, as well as calculations of the mean and interpretation of the results in policy decisions. Additional shortcomings to current monitoring approaches include appropriateness and reliability of currently used indicator bacteria and the overall goal of these monitoring programs. Current research is attempting to circumvent these complex issues by developing new tools and methods for beach monitoring. In this review, we highlight the variety of sampling routines used across the Great Lakes and the extensive body of research that challenges comparisons among beaches. We also assess the future of Great Lakes monitoring and the advantages and disadvantages of establishing standards that are evenly applied across all beaches.

  19. Methods And Devices For Characterizing Duplex Nucleic Acid Molecules

    DOEpatents

    Akeson, Mark; Vercoutere, Wenonah; Haussler, David; Winters-Hilt, Stephen

    2005-08-30

    Methods and devices are provided for characterizing a duplex nucleic acid, e.g., a duplex DNA molecule. In the subject methods, a fluid conducting medium that includes a duplex nucleic acid molecule is contacted with a nanopore under the influence of an applied electric field and the resulting changes in current through the nanopore caused by the duplex nucleic acid molecule are monitored. The observed changes in current through the nanopore are then employed as a set of data values to characterize the duplex nucleic acid, where the set of data values may be employed in raw form or manipulated, e.g., into a current blockade profile. Also provided are nanopore devices for practicing the subject methods, where the subject nanopore devices are characterized by the presence of an algorithm which directs a processing means to employ monitored changes in current through a nanopore to characterize a duplex nucleic acid molecule responsible for the current changes. The subject methods and devices find use in a variety of applications, including, among other applications, the identification of an analyte duplex DNA molecule in a sample, the specific base sequence at a single nulceotide polymorphism (SNP), and the sequencing of duplex DNA molecules.

  20. Hardware Specific Integration Strategy for Impedance-Based Structural Health Monitoring of Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Owen, Robert B.; Gyekenyesi, Andrew L.; Inman, Daniel J.; Ha, Dong S.

    2011-01-01

    The Integrated Vehicle Health Management (IVHM) Project, sponsored by NASA's Aeronautics Research Mission Directorate, is conducting research to advance the state of highly integrated and complex flight-critical health management technologies and systems. An effective IVHM system requires Structural Health Monitoring (SHM). The impedance method is one such SHM technique for detection and monitoring complex structures for damage. This position paper on the impedance method presents the current state of the art, future directions, applications and possible flight test demonstrations.

  1. Forward voltage short-pulse technique for measuring high power laser array junction temperature

    NASA Technical Reports Server (NTRS)

    Meadows, Byron L. (Inventor); Amzajerdian, Frazin (Inventor); Barnes, Bruce W. (Inventor); Baker, Nathaniel R. (Inventor)

    2012-01-01

    The present invention relates to a method of measuring the temperature of the P-N junction within the light-emitting region of a quasi-continuous-wave or pulsed semiconductor laser diode device. A series of relatively short and low current monitor pulses are applied to the laser diode in the period between the main drive current pulses necessary to cause the semiconductor to lase. At the sufficiently low current level of the monitor pulses, the laser diode device does not lase and behaves similar to an electronic diode. The voltage across the laser diode resulting from each of these low current monitor pulses is measured with a high degree of precision. The junction temperature is then determined from the measured junction voltage using their known linear relationship.

  2. Configurations and calibration methods for passive sampling techniques.

    PubMed

    Ouyang, Gangfeng; Pawliszyn, Janusz

    2007-10-19

    Passive sampling technology has developed very quickly in the past 15 years, and is widely used for the monitoring of pollutants in different environments. The design and quantification of passive sampling devices require an appropriate calibration method. Current calibration methods that exist for passive sampling, including equilibrium extraction, linear uptake, and kinetic calibration, are presented in this review. A number of state-of-the-art passive sampling devices that can be used for aqueous and air monitoring are introduced according to their calibration methods.

  3. Evidence supporting the need for a common soil monitoring protocol

    Treesearch

    Derrick A. Reeves; Mark D. Coleman; Deborah S. Page-Dumroese

    2013-01-01

    Many public land management agencies monitor forest soils for levels of disturbance related to management activities. Although several soil disturbance monitoring protocols based on visual observation have been developed to assess the amount and types of disturbance caused by forest management, no common method is currently used on National Forest lands in the United...

  4. A Coupled model for ERT monitoring of contaminated sites

    NASA Astrophysics Data System (ADS)

    Wang, Yuling; Zhang, Bo; Gong, Shulan; Xu, Ya

    2018-02-01

    The performance of electrical resistivity tomography (ERT) system is usually investigated using a fixed resistivity distribution model in numerical simulation study. In this paper, a method to construct a time-varying resistivity model by coupling water transport, solute transport and constant current field is proposed for ERT monitoring of contaminated sites. Using the proposed method, a monitoring model is constructed for a contaminated site with a pollution region on the surface and ERT monitoring results at different time is calculated by the finite element method. The results show that ERT monitoring profiles can effectively reflect the increase of the pollution area caused by the diffusion of pollutants, but the extent of the pollution is not exactly the same as the actual situation. The model can be extended to any other case and can be used to scheme design and results analysis for ERT monitoring.

  5. TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A, Popescu I; Lobo, J; Sawkey, D

    2014-06-15

    Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulationsmore » in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.« less

  6. DESIGN AND IMPLEMENTATION OF EFFECTIVE MONITORING PROGRAMS FOR DREDGING CONTAMINATED SEDIMENT

    EPA Science Inventory

    Currently, there is a growing national debate about dredging contaminated sediments, including risks to human health and the environment as well as the overall effectiveness of remedial activities. Presently, monitoring methods are available to address both concerns. This present...

  7. HANDBOOK: CONTINUOUS EMISSION MONITORING SYSTEMS FOR NON-CRITERIA POLLUTANTS

    EPA Science Inventory

    This Handbook provides a description of the methods used to continuously monitor non-criteria pollutants emitted from stationary sources. The Handbook contains a review of current regulatory programs, the state-of-the-art sampling system design, analytical techniques, and the use...

  8. A combination of HPLC and automated data analysis for monitoring the efficiency of high-pressure homogenization.

    PubMed

    Eggenreich, Britta; Rajamanickam, Vignesh; Wurm, David Johannes; Fricke, Jens; Herwig, Christoph; Spadiut, Oliver

    2017-08-01

    Cell disruption is a key unit operation to make valuable, intracellular target products accessible for further downstream unit operations. Independent of the applied cell disruption method, each cell disruption process must be evaluated with respect to disruption efficiency and potential product loss. Current state-of-the-art methods, like measuring the total amount of released protein and plating-out assays, are usually time-delayed and involve manual intervention making them error-prone. An automated method to monitor cell disruption efficiency at-line is not available to date. In the current study we implemented a methodology, which we had originally developed to monitor E. coli cell integrity during bioreactor cultivations, to automatically monitor and evaluate cell disruption of a recombinant E. coli strain by high-pressure homogenization. We compared our tool with a library of state-of-the-art methods, analyzed the effect of freezing the biomass before high-pressure homogenization and finally investigated this unit operation in more detail by a multivariate approach. A combination of HPLC and automated data analysis describes a valuable, novel tool to monitor and evaluate cell disruption processes. Our methodology, which can be used both in upstream (USP) and downstream processing (DSP), describes a valuable tool to evaluate cell disruption processes as it can be implemented at-line, gives results within minutes after sampling and does not need manual intervention.

  9. Evaluating a new method for monitoring the field establishment and parasitism of Oobius agrili, an egg parasitoid of the emerald ash borer

    USDA-ARS?s Scientific Manuscript database

    Oobius agrili is a solitary egg parasitoid of emerald ash borer (EAB), Agrilus planipennis, and can be responsible for 50-60% of EAB egg mortality in its native range. O. agrili has been released for biological control of EAB in the US since 2007; however, current methods to monitor its establishme...

  10. Ice Detection and Mitigation Device

    NASA Technical Reports Server (NTRS)

    Gambino, Richard J. (Inventor); Gouldstone, Christopher (Inventor); Gutleber, Jonathan (Inventor); Hubble, David (Inventor); Trelewicz, Jason (Inventor)

    2016-01-01

    A method for deicing an aerostructure includes driving a sensing current through a heater element coated to an aerostructure, the heater element having a resistance that is temperature dependent. A resistance of the heater element is monitored. It is determined whether there is icing at the heater element using the monitored resistance of the heater element. A melting current is driven through the heater element when it is determined that there is icing at the heater element.

  11. Prestressing force monitoring method for a box girder through distributed long-gauge FBG sensors

    NASA Astrophysics Data System (ADS)

    Chen, Shi-Zhi; Wu, Gang; Xing, Tuo; Feng, De-Cheng

    2018-01-01

    Monitoring prestressing forces is essential for prestressed concrete box girder bridges. However, the current monitoring methods used for prestressing force were not applicable for a box girder neither because of the sensor’s setup being constrained or shear lag effect not being properly considered. Through combining with the previous analysis model of shear lag effect in the box girder, this paper proposed an indirect monitoring method for on-site determination of prestressing force in a concrete box girder utilizing the distributed long-gauge fiber Bragg grating sensor. The performance of this method was initially verified using numerical simulation for three different distribution forms of prestressing tendons. Then, an experiment involving two concrete box girders was conducted to study the feasibility of this method under different prestressing levels preliminarily. The results of both numerical simulation and lab experiment validated this method’s practicability in a box girder.

  12. A review of protocols for monitoring streams and juvenile fish in forested regions of the Pacific Northwest.

    Treesearch

    Scott A. Stolnack; Mason D. Bryant; Robert C. Wissmar

    2005-01-01

    This document reviews existing and proposed protocols used to monitor stream ecosystem conditions and responses to land management activities in the Pacific Northwest. Because of recent work aimed at improving the utility of habitat survey and fish abundance assessment methods, this review focuses on current (since 1993) monitoring efforts that assess stream habitat...

  13. A new method for wireless video monitoring of bird nests

    Treesearch

    David I. King; Richard M. DeGraaf; Paul J. Champlin; Tracey B. Champlin

    2001-01-01

    Video monitoring of active bird nests is gaining popularity among researchers because it eliminates many of the biases associated with reliance on incidental observations of predation events or use of artificial nests, but the expense of video systems may be prohibitive. Also, the range and efficiency of current video monitoring systems may be limited by the need to...

  14. Towards 24/7 continuous heart rate monitoring.

    PubMed

    Tarniceriu, Adrian; Parak, Jakub; Renevey, Philippe; Nurmi, Marko; Bertschi, Mattia; Delgado-Gonzalo, Ricard; Korhonen, Ilkka

    2016-08-01

    Heart rate (HR) and HR variability (HRV) carry rich information about physical activity, mental and physical load, physiological status, and health of an individual. When combined with activity monitoring and personalized physiological modelling, HR/HRV monitoring may be used for monitoring of complex behaviors and impact of behaviors and external factors on the current physiological status of an individual. Optical HR monitoring (OHR) from wrist provides a comfortable and unobtrusive method for HR/HRV monitoring and is better adhered by users than traditional ECG electrodes or chest straps. However, OHR power consumption is significantly higher than that for ECG based methods due to the measurement principle based on optical illumination of the tissue. We developed an algorithmic approach to reduce power consumption of the OHR in 24/7 HR trending. We use continuous activity monitoring and a fast converging frequency domain algorithm to derive a reliable HR estimate in 7.1s (during outdoor sports, in average) to 10.0s (during daily life). The method allows >80% reduction in power consumption in 24/7 OHR monitoring when average HR monitoring is targeted, without significant reduction in tracking accuracy.

  15. Determination of torque speed current characteristics of a brushless DC motor by utilizing back-EMF of non-energized phase

    NASA Astrophysics Data System (ADS)

    Jang, G. H.; Yeom, J. H.; Kim, M. G.

    2007-03-01

    This paper presents a method to determine the torque constant and the torque-speed-current characteristics of a brushless DC (BLDC) motor by utilizing back-EMF variation of nonenergized phase. It also develops a BLDC motor controller with a digital signal processor (DSP) to monitor its current, voltage and speed in real time. Torque-speed-current characteristics of a BLDC motor are determined by using the proposed method and the developed controller. They are compared with the torque-speed-current characteristics measured by dynamometer experimentally. This research shows that the proposed method is an effective method to determine the torque constant and the torque-speed-current characteristics of the BLDC motor without using dynamometer.

  16. Method and apparatus for monitoring machine performance

    DOEpatents

    Smith, Stephen F.; Castleberry, Kimberly N.

    1996-01-01

    Machine operating conditions can be monitored by analyzing, in either the time or frequency domain, the spectral components of the motor current. Changes in the electric background noise, induced by mechanical variations in the machine, are correlated to changes in the operating parameters of the machine.

  17. Current deflection NDE for pipeline inspection and monitoring

    NASA Astrophysics Data System (ADS)

    Jarvis, Rollo; Cawley, Peter; Nagy, Peter B.

    2016-02-01

    Failure of oil and gas pipelines can often be catastrophic, therefore routine inspection for time dependent degradation is essential. In-line inspection is the most common method used; however, this requires the insertion and retrieval of an inspection tool that is propelled by the fluid in the pipe and risks becoming stuck, so alternative methods must often be employed. This work investigates the applicability of a non-destructive evaluation technique for both the detection and growth monitoring of defects, particularly corrosion under insulation. This relies on injecting an electric current along the pipe and indirectly measuring the deflection of current around defects from perturbations in the orthogonal components of the induced magnetic flux density. An array of three orthogonally oriented anisotropic magnetoresistive sensors has been used to measure the magnetic flux density surrounding a 6'' schedule-40 steel pipe carrying 2 A quasi-DC axial current. A finite element model has been developed that predicts the perturbations in magnetic flux density caused by current deflection which has been validated by experimental results. Measurements of the magnetic flux density at 50 mm lift-off from the pipe surface are stable and repeatable to the order of 100 pT which suggests that defect detection or monitoring growth of corrosion-type defects may be possible with a feasible magnitude of injected current. Magnetic signals are additionally incurred by changes in the wall thickness of the pipe due to manufacturing tolerances, and material property variations. If a monitoring scheme using baseline subtraction is employed then the sensitivity to defects can be improved while avoiding false calls.

  18. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    NASA Astrophysics Data System (ADS)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  19. Advances in Audio-Based Systems to Monitor Patient Adherence and Inhaler Drug Delivery.

    PubMed

    Taylor, Terence E; Zigel, Yaniv; De Looze, Céline; Sulaiman, Imran; Costello, Richard W; Reilly, Richard B

    2018-03-01

    Hundreds of millions of people worldwide have asthma and COPD. Current medications to control these chronic respiratory diseases can be administered using inhaler devices, such as the pressurized metered dose inhaler and the dry powder inhaler. Provided that they are used as prescribed, inhalers can improve patient clinical outcomes and quality of life. Poor patient inhaler adherence (both time of use and user technique) is, however, a major clinical concern and is associated with poor disease control, increased hospital admissions, and increased mortality rates, particularly in low- and middle-income countries. There are currently limited methods available to health-care professionals to objectively and remotely monitor patient inhaler adherence. This review describes recent sensor-based technologies that use audio-based approaches that show promising opportunities for monitoring inhaler adherence in clinical practice. This review discusses how one form of sensor-based technology, audio-based monitoring systems, can provide clinically pertinent information regarding patient inhaler use over the course of treatment. Audio-based monitoring can provide health-care professionals with quantitative measurements of the drug delivery of inhalers, signifying a clear clinical advantage over other methods of assessment. Furthermore, objective audio-based adherence measures can improve the predictability of patient outcomes to treatment compared with current standard methods of adherence assessment used in clinical practice. Objective feedback on patient inhaler adherence can be used to personalize treatment to the patient, which may enhance precision medicine in the treatment of chronic respiratory diseases. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  20. Deflection monitoring for a box girder based on a modified conjugate beam method

    NASA Astrophysics Data System (ADS)

    Chen, Shi-Zhi; Wu, Gang; Xing, Tuo

    2017-08-01

    After several years of operation, a box girder bridge would commonly experience excessive deflection, which endangers the bridge’s life span as well as the safety of vehicles travelling on it. In order to avoid potential risks, it is essential to constantly monitor the defection of box girders. However, currently, the direct deflection monitoring methods are limited by the complicated environments beneath the bridges, such as rivers or other traffic lanes, which severely impede the layouts of the sensors. The other indirect deflection monitoring methods mostly do not thoroughly consider the inherent shear lag effect and shear deformation in the box girder, resulting in a rather large error. Under these circumstances, a deflection monitoring method suiting box girders is proposed in this article, based on the conjugate beam method and distributed long-gauge fibre Bragg grating (FBG) sensor. A lab experiment was conducted to verify the reliability and feasibility of this method under practical application. Further, the serviceability under different span-depth ratios and web thicknesses was examined through a finite element model.

  1. Analytical procedures for water-soluble vitamins in foods and dietary supplements: a review.

    PubMed

    Blake, Christopher J

    2007-09-01

    Water-soluble vitamins include the B-group vitamins and vitamin C. In order to correctly monitor water-soluble vitamin content in fortified foods for compliance monitoring as well as to establish accurate data banks, an accurate and precise analytical method is a prerequisite. For many years microbiological assays have been used for analysis of B vitamins. However they are no longer considered to be the gold standard in vitamins analysis as many studies have shown up their deficiencies. This review describes the current status of analytical methods, including microbiological assays and spectrophotometric, biosensor and chromatographic techniques. In particular it describes the current status of the official methods and highlights some new developments in chromatographic procedures and detection methods. An overview is made of multivitamin extractions and analyses for foods and supplements.

  2. LARGE RIVER ASSESSMENT METHODS FOR BENTHIC MACROINVERTEBRATES AND FISH

    EPA Science Inventory

    Multiple projects are currently underway to increase our understanding of the varying results of different sampling methods and designs used for the biological assessment and monitoring of large (boatable) rivers. Studies include methods used to assess fish, benthic macroinverte...

  3. A NEW APPROACH TO PIP CROP MONITORING USING REMOTE SENSING

    EPA Science Inventory

    Current plantings of 25+ million acres of transgenic corn in the United States require a new approach to monitor this important crop for the development of pest resistance. Remote sensing by aerial or satellite images may provide a method of identifying transgenic pesticidal cro...

  4. PROTECTING HEALTH WITH SAME DAY WATER QUALITY MONITORING RESULTS FOR BATHING BEACHES

    EPA Science Inventory

    Current US Environmental Protection Agency guidelines recommend the use of cultural methods for E. coli and enterococci to monitor beach water quality. The guidelines recommend a single sample value or a geometric mean value from at least five samples. The single sample guideli...

  5. WATERBORNE DISEASES AND MICROBIAL QUALITY MONITORING FOR RECREATIONAL WATER BODIES USING REGULATORY METHODS

    EPA Science Inventory

    This chapter will provide the reader with a historical perspective of microbial water quality and monitoring of recreational waters, with special attention to marine environments. It will review the regulations that are currently in effect in the United States and discuss critic...

  6. Assessing physical activity using wearable monitors: measures of physical activity.

    PubMed

    Butte, Nancy F; Ekelund, Ulf; Westerterp, Klaas R

    2012-01-01

    Physical activity may be defined broadly as "all bodily actions produced by the contraction of skeletal muscle that increase energy expenditure above basal level." Physical activity is a complex construct that can be classified into major categories qualitatively, quantitatively, or contextually. The quantitative assessment of physical activity using wearable monitors is grounded in the measurement of energy expenditure. Six main categories of wearable monitors are currently available to investigators: pedometers, load transducers/foot-contact monitors, accelerometers, HR monitors, combined accelerometer and HR monitors, and multiple sensor systems. Currently available monitors are capable of measuring total physical activity as well as components of physical activity that play important roles in human health. The selection of wearable monitors for measuring physical activity will depend on the physical activity component of interest, study objectives, characteristics of the target population, and study feasibility in terms of cost and logistics. Future development of sensors and analytical techniques for assessing physical activity should focus on the dynamic ranges of sensors, comparability for sensor output across manufacturers, and the application of advanced modeling techniques to predict energy expenditure and classify physical activities. New approaches for qualitatively classifying physical activity should be validated using direct observation or recording. New sensors and methods for quantitatively assessing physical activity should be validated in laboratory and free-living populations using criterion methods of calorimetry or doubly labeled water.

  7. Biomechanical monitoring of healing bone based on acoustic emission technology.

    PubMed

    Hirasawa, Yasusuke; Takai, Shinro; Kim, Wook-Cheol; Takenaka, Nobuyuki; Yoshino, Nobuyuki; Watanabe, Yoshinobu

    2002-09-01

    Acoustic emission testing is a well-established method for assessment of the mechanical integrity of general construction projects. The purpose of the current study was to investigate the usefulness of acoustic emission technology in monitoring the yield strength of healing callus during external fixation. Thirty-five patients with 39 long bones treated with external fixation were evaluated for fracture healing by monitoring load for the initiation of acoustic emission signal (yield strength) under axial loading. The major criteria for functional bone union based on acoustic emission testing were (1) no acoustic emission signal on full weightbearing, and (2) a higher estimated strength than body weight. The yield strength monitored by acoustic emission testing increased with the time of healing. The external fixator could be removed safely and successfully in 97% of the patients. Thus, the acoustic emission method has good potential as a reliable method for monitoring the mechanical status of healing bone.

  8. A review of the developments of radioxenon detectors for nuclear explosion monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivels, Ciara B.; McIntyre, Justin I.; Bowyer, Theodore W.

    Developments in radioxenon monitoring since the implementation of the International Monitoring System are reviewed with emphasis on the most current technologies to improve detector sensitivity and resolution. The nuclear detectors reviewed include combinations of plastic and NaI(Tl) detectors, high purity germanium detectors, silicon detectors, and phoswich detectors. The minimum detectable activity and calibration methods for the various detectors are also discussed.

  9. Current methods for detecting ethylene in plants

    PubMed Central

    Cristescu, Simona M.; Mandon, Julien; Arslanov, Denis; De Pessemier, Jérôme; Hermans, Christian; Harren, Frans J. M.

    2013-01-01

    Background In view of ethylene's critical developmental and physiological roles the gaseous hormone remains an active research topic for plant biologists. Progress has been made to understand the ethylene biosynthesis pathway and the mechanisms of perception and action. Still numerous questions need to be answered and findings to be validated. Monitoring gas production will very often complete the picture of any ethylene research topic. Therefore the search for suitable ethylene measuring methods for various plant samples either in the field, greenhouses, laboratories or storage facilities is strongly motivated. Scope This review presents an update of the current methods for ethylene monitoring in plants. It focuses on the three most-used methods – gas chromatography detection, electrochemical sensing and optical detection – and compares them in terms of sensitivity, selectivity, time response and price. Guidelines are provided for proper selection and application of the described sensor methodologies and some specific applications are illustrated of laser-based detector for monitoring ethylene given off by Arabidopsis thaliana upon various nutritional treatments. Conclusions Each method has its advantages and limitations. The choice for the suitable ethylene sensor needs careful consideration and is driven by the requirements for a specific application. PMID:23243188

  10. 78 FR 22540 - Notice of Public Meeting/Webinar: EPA Method Development Update on Drinking Water Testing Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ...: EPA Method Development Update on Drinking Water Testing Methods for Contaminant Candidate List... Division will describe methods currently in development for many CCL contaminants, with an expectation that several of these methods will support future cycles of the Unregulated Contaminant Monitoring Rule (UCMR...

  11. An integrated approach to detecting and monitoring chemicals of biological concern in Great Lakes ecosystems

    EPA Science Inventory

    Chemical monitoring strategies are most effective for those chemicals whose hazards are well understood and for which sensitive and cost effective analytical methods are available. Unfortunately, such chemicals represent a minor fraction of those that may currently occur in the e...

  12. Community noise monitoring program

    Treesearch

    Arnold G. Konheim

    1977-01-01

    There are numerous questions in regard to methods, instrumentation, and human and agency resources for community noise monitoring. The U. S. Environmental Protection Agency is currently in the process of seeking answers to these questions through research within the agency and by cooperation with other organizations, including the Department of Defense and the National...

  13. Health Monitoring of a Planetary Rover Using Hybrid Particle Petri Nets

    NASA Technical Reports Server (NTRS)

    Gaudel, Quentin; Ribot, Pauline; Chanthery, Elodie; Daigle, Matthew J.

    2016-01-01

    This paper focuses on the application of a Petri Net-based diagnosis method on a planetary rover prototype.The diagnosis is performed by using a model-based method in the context of health management of hybrid systems.In system health management, the diagnosis task aims at determining the current health state of a system and the fault occurrences that lead to this state. The Hybrid Particle Petri Nets (HPPN) formalism is used to model hybrid systems behavior and degradation, and to define the generation of diagnosers to monitor the health states of such systems under uncertainty. At any time, the HPPN-based diagnoser provides the current diagnosis represented by a distribution of beliefs over the health states. The health monitoring methodology is demonstrated on the K11 rover. A hybrid model of the K11 is proposed and experimental results show that the approach is robust to real system data and constraints.

  14. System for evaluating weld quality using eddy currents

    DOEpatents

    Todorov, Evgueni I.; Hay, Jacob

    2017-12-12

    Electromagnetic and eddy current techniques for fast automated real-time and near real-time inspection and monitoring systems for high production rate joining processes. An eddy current system, array and method for the fast examination of welds to detect anomalies such as missed seam (MS) and lack of penetration (LOP) the system, array and methods capable of detecting and sizing surface and slightly subsurface flaws at various orientations in connection with at least the first and second weld pass.

  15. Conductivity detection for monitoring mixing reactions in microfluidic devices.

    PubMed

    Liu, Y; Wipf, D O; Henry, C S

    2001-08-01

    A conductivity detector was coupled to poly(dimethylsiloxane)-glass capillary electrophoresis microchips to monitor microfluidic flow. Electroosmotic flow was investigated with both conductivity detection (CD) and the current monitoring method. No significant variation was observed between these methods, but CD showed a lower relative standard deviation. Gradient mixing experiments were employed to investigate the relationship between the electrolyte conductivity and the electrolyte concentration. A good linear response of conductivity to concentration was obtained for solutions whose difference in concentrations were less than 27 mM. The new system holds great promise for precision mixing in microfluidic devices using electrically driven flows.

  16. Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations

    NASA Technical Reports Server (NTRS)

    Montgomery, Demaris A.

    2001-01-01

    In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.

  17. Relationships between Lexical Processing Speed, Language Skills, and Autistic Traits in Children

    ERIC Educational Resources Information Center

    Abrigo, Erin

    2012-01-01

    According to current models of spoken word recognition listeners understand speech as it unfolds over time. Eye tracking provides a non-invasive, on-line method to monitor attention, providing insight into the processing of spoken language. In the current project a spoken lexical processing assessment (LPA) confirmed current theories of spoken…

  18. Expert systems for real-time monitoring and fault diagnosis

    NASA Technical Reports Server (NTRS)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  19. Pharmacists' perspectives on monitoring adherence to treatment in Cystic Fibrosis.

    PubMed

    Mooney, Karen; Ryan, Cristín; Downey, Damian G

    2016-04-01

    Cystic Fibrosis (CF) management requires complex treatment regimens but adherence to treatment is poor and has negative health implications. There are various methods of measuring adherence, but little is known regarding the extent of adherence measurement in CF centres throughout the UK and Ireland. To determine the adherence monitoring practices in CF centres throughout the UK and Ireland, and to establish CF pharmacists' views on these practices. UK and Ireland Cystic Fibrosis Pharmacists' Group's annual meeting (2014). A questionnaire was designed, piloted and distributed to pharmacists attending the UK and Ireland Cystic Fibrosis Pharmacists' Group's annual meeting (2014). The main outcome measures were the methods of inhaled/nebulised antibiotic supply and the methods used to measure treatment adherence in CF centres. The questionnaire also ascertained the demographic information of participating pharmacists. Closed question responses were analysed using descriptive statistics. Open questions were analysed using content analysis. Twenty-one respondents (84 % response) were included in the analysis and were mostly from English centres (66.7 %). Detailed records of patients receiving their inhaled/nebulised antibiotics were lacking. Adherence was most commonly described to be measured at 'every clinic visit' (28.6 %) and 'occasionally' (28.6 %). Patient self-reported adherence was the most commonly used method of measuring adherence in practice (90.5 %). The availability of electronic adherence monitoring in CF centres did not guarantee its use. Pharmacists attributed an equal professional responsibility for adherence monitoring in CF to Consultants, Nurses and Pharmacists. Seventy-six percent of pharmacists felt that the current adherence monitoring practices within their own unit were inadequate and associated with the absence of sufficient specialist CF pharmacist involvement. Many suggested that greater specialist pharmacist involvement could facilitate improved adherence monitoring. Current adherence knowledge is largely based on self-report. Further work is required to establish the most appropriate method of adherence monitoring in CF centres, to improve the recording of adherence and to understand the impact of increased specialist pharmacist involvement on that adherence.

  20. Motor current signature analysis method for diagnosing motor operated devices

    DOEpatents

    Haynes, Howard D.; Eissenberg, David M.

    1990-01-01

    A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

  1. Refinement of current monitoring methodology for electroosmotic flow assessment under low ionic strength conditions

    PubMed Central

    Saucedo-Espinosa, Mario A.; Lapizco-Encinas, Blanca H.

    2016-01-01

    Current monitoring is a well-established technique for the characterization of electroosmotic (EO) flow in microfluidic devices. This method relies on monitoring the time response of the electric current when a test buffer solution is displaced by an auxiliary solution using EO flow. In this scheme, each solution has a different ionic concentration (and electric conductivity). The difference in the ionic concentration of the two solutions defines the dynamic time response of the electric current and, hence, the current signal to be measured: larger concentration differences result in larger measurable signals. A small concentration difference is needed, however, to avoid dispersion at the interface between the two solutions, which can result in undesired pressure-driven flow that conflicts with the EO flow. Additional challenges arise as the conductivity of the test solution decreases, leading to a reduced electric current signal that may be masked by noise during the measuring process, making for a difficult estimation of an accurate EO mobility. This contribution presents a new scheme for current monitoring that employs multiple channels arranged in parallel, producing an increase in the signal-to-noise ratio of the electric current to be measured and increasing the estimation accuracy. The use of this parallel approach is particularly useful in the estimation of the EO mobility in systems where low conductivity mediums are required, such as insulator based dielectrophoresis devices. PMID:27375813

  2. Amperometric monitoring of quercetin permeation through skin membranes.

    PubMed

    Rembiesa, Jadwiga; Gari, Hala; Engblom, Johan; Ruzgas, Tautgirdas

    2015-12-30

    Transdermal delivery of quercetin (QR, 3,3',4',5,7-pentahydroxyflavone), a natural flavonoid with a considerable antioxidant capacity, is important for medical treatment of, e.g., skin disorders. QR permeability through skin is low, which, at the same time, makes the monitoring of percutaneous QR penetration difficult. The objective of this study was to assess an electrochemical method for monitoring QR penetration through skin membranes. An electrode was covered with the membrane, exposed to QR solution, and electrode current was measured. The registered current was due to electro-oxidation of QR penetrating the membrane. Exploiting strict current-QR flux relationships diffusion coefficient, D, of QR in skin and dialysis membranes was calculated. The D values were strongly dependent on the theoretical model and parameters assumed in the processing of the amperometric data. The highest values of D were in the range of 1.6-6.1×10(-7)cm(2)/s. This was reached only for skin membranes pretreated with buffer-ethanol mixture for more than 24h. QR solutions containing penetration enhancers, ethanol and l-menthol, definitely increased D values. The results demonstrate that electrochemical setup gives a possibility to assess penetration characteristics as well as enables monitoring of penetration dynamics, which is more difficult by traditional methods using Franz cells. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Current strategies for monitoring men with localised prostate cancer lack a strong evidence base: observational longitudinal study.

    PubMed

    Metcalfe, C; Tilling, K; Davis, M; Lane, J A; Martin, R M; Kynaston, H; Powell, P; Neal, D E; Hamdy, F; Donovan, J L

    2009-08-04

    The UK National Institute for Health and Clinical Excellence (NICE) guidance recommends conservative management of men with 'low-risk' localised prostate cancer, monitoring the disease using prostate-specific antigen (PSA) kinetics and re-biopsy. However, there is little evidence of the changes in PSA level that should alert to the need for clinical re-assessment. This study compares the alerts resulting from PSA kinetics and a novel longitudinal reference range approach, which incorporates age-related changes, during the monitoring of 408 men with localised prostate cancer. Men were monitored by regular PSA tests over a mean of 2.9 years, recording when a man's PSA doubling time fell below 2 years, PSA velocity exceeded 2 ng ml(-1) per year, or when his upper 10% reference range was exceeded. Prostate-specific antigen doubling time and PSA velocity alerted a high proportion of men initially but became unresponsive to changes with successive tests. Calculating doubling time using recent PSA measurements reduced the decline in response. The reference range method maintained responsiveness to changes in PSA level throughout the monitoring. The increasing unresponsiveness of PSA kinetics is a consequence of the underlying regression model. Novel methods are needed for evaluation in cohorts currently being managed by monitoring. Meanwhile, the NICE guidance should be cautious.

  4. A framework to determine the locations of the environmental monitoring in an estuary of the Yellow Sea.

    PubMed

    Kim, Nam-Hoon; Hwang, Jin Hwan; Cho, Jaegab; Kim, Jae Seong

    2018-06-04

    The characteristics of an estuary are determined by various factors as like as tide, wave, river discharge, etc. which also control the water quality of the estuary. Therefore, detecting the changes of characteristics is critical in managing the environmental qualities and pollution and so the locations of monitoring should be selected carefully. The present study proposes a framework to deploy the monitoring systems based on a graphical method of the spatial and temporal optimizations. With the well-validated numerical simulation results, the monitoring locations are determined to capture the changes of water qualities and pollutants depending on the variations of tide, current and freshwater discharge. The deployment strategy to find the appropriate monitoring locations is designed with the constrained optimization method, which finds solutions by constraining the objective function into the feasible regions. The objective and constrained functions are constructed with the interpolation technique such as objective analysis. Even with the smaller number of the monitoring locations, the present method performs well equivalently to the arbitrarily and evenly deployed monitoring system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Methods for Specific Electrode Resistance Measurement during Transcranial Direct Current Stimulation

    PubMed Central

    Khadka, Niranjan; Rahman, Asif; Sarantos, Chris; Truong, Dennis Q.; Bikson, Marom

    2014-01-01

    Background Transcranial Direct Current Stimulation (tDCS) is investigated to treat a wide range of neuropsychiatric disorders, for rehabilitation, and for enhancing cognitive performance. The monitoring of electrode resistance before and during tDCS is considered important for tolerability and safety, where an unusually high resistance is indicative of undesired electrode or poor skin contact conditions. Conventional resistance measurement methods do not isolate individual electrode resistance but rather measures overall voltage. Moreover, for HD-tDCS devices, cross talk across electrodes makes concurrent resistance monitoring unreliable. Objective We propose a novel method for monitoring of the individual electrode resistance during tDCS, using a super-position of direct current with a test-signal (low-intensity and low-frequency sinusoids with electrode– specific frequencies) and a single sentinel electrode (not used for DC). Methods To validate this methodology, we developed lumped-parameter models of two and multi-electrode tDCS. Approaches with and without a sentinel electrode were solved and underlying assumptions identified. Assumptions were tested and parameterized in healthy participants using forearm stimulation combining tDCS (2 mA) and sinusoidal test-signals (38 μA and 76 μA peak to peak at 1 Hz, 10 Hz, and 100 Hz) and an in vitro test (where varied electrode failure modes were created). DC and AC component voltages across the electrodes were compared and participants were asked to rate subjective pain. Results A sentinel electrode is required to isolate electrode resistance in a two-electrode tDCS system. For multi-electrode resistance tracking, cross talk was aggravated with electrode proximity and current/resistance mismatches, but could be corrected using proposed approaches. Average voltage and average pain scores were not significantly different across test current intensities and frequencies (two-way repeated measures ANOVA) indicating the test signal does not itself confound electrode stability or sensation. DC-resistance to AC-impedance ratio was ~1:08, averaged across frequencies. Conclusion Using the methods developed here, a test signal can predict DC electrode resistance. Since unique test frequencies can be used at each tDCS electrode, specific electrode resistance can be resolved for any number of stimulating channels – a process made still more robust by the use of a sentinel electrode. These findings provide the first method for monitoring individual electrode resistance during tDCS that integrated into devices may minimize irritation at electrodes. PMID:25456981

  6. HOLDING TIME STUDY FOR FECALS/SALMONELLA & CONNECTING LANGUAGE FOR 503 REGULATIONS

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella have been developed and are currently in use for quantification of these organisms. Recently c...

  7. Sensitive method to monitor trace quantities of benzanthrone in workers of dyestuff industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, A.; Khanna, S.K.; Singh, G.B.

    1986-03-01

    Dyestuff workers coming in contact with benzanthrone (an intermediate used for the synthesis of a variety of dyes) develop skin lesions, gastritis, liver malfunctions, and sexual disturbances. A highly sensitive fluorometric method to monitor trace quantities of benzanthrone in urine, serum, and biological tissues for experimental studies, has been developed. Coupled with simple extraction and resolution, optimum fluorescence is obtained in an equal mixture of chloroform:methanol, detecting as low as 2 ng benzanthrone. This method is approximately 250 times more sensitive than currently available colorimetric assay.

  8. Advanced image based methods for structural integrity monitoring: Review and prospects

    NASA Astrophysics Data System (ADS)

    Farahani, Behzad V.; Sousa, Pedro José; Barros, Francisco; Tavares, Paulo J.; Moreira, Pedro M. G. P.

    2018-02-01

    There is a growing trend in engineering to develop methods for structural integrity monitoring and characterization of in-service mechanical behaviour of components. The fast growth in recent years of image processing techniques and image-based sensing for experimental mechanics, brought about a paradigm change in phenomena sensing. Hence, several widely applicable optical approaches are playing a significant role in support of experiment. The current review manuscript describes advanced image based methods for structural integrity monitoring, and focuses on methods such as Digital Image Correlation (DIC), Thermoelastic Stress Analysis (TSA), Electronic Speckle Pattern Interferometry (ESPI) and Speckle Pattern Shearing Interferometry (Shearography). These non-contact full-field techniques rely on intensive image processing methods to measure mechanical behaviour, and evolve even as reviews such as this are being written, which justifies a special effort to keep abreast of this progress.

  9. Methods for shorebird surveys in the Arctic

    Treesearch

    Jonathan Bart; Susan L. Earnst

    2005-01-01

    A substantial effort is being made to develop a longterm monitoring program for shorebirds in North American (Brown et al. 2000, Donaldson et al. 2001, Bart et al. this volume). The current program, PRISM (Program for Regional and International Shorebird Monitoring), has four segments: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-...

  10. Predictors of Daily Blood Glucose Monitoring in Appalachian Ohio

    ERIC Educational Resources Information Center

    Raffle, Holly; Ware, Lezlee J.; Ruhil, Anirudh V. S.; Hamel-Lambert, Jane; Denham, Sharon A.

    2012-01-01

    Objective: To determine factors contributing to successful diabetes self-management in Appalachia, as evidenced by daily blood glucose monitoring. Methods: A telephone survey (N = 3841) was conducted to assess health status and health care access. The current investigation is limited to the subset of this sample who report having diabetes (N =…

  11. Continuous turbidity monitoring in streams of northwestern California

    Treesearch

    Rand Eads; Jack Lewis

    2002-01-01

    Abstract - Redwood Sciences Laboratory, a field office of the USDA Forest Service, Pacific Southwest Research Station has developed and refined methods and instrumentation to monitor turbidity and suspended sediment in streams of northern California since 1996. Currently we operate 21 stations and have provided assistance in the installation of 6 gaging stations for...

  12. Application of an integrated strategy for monitoring of contaminants, including endocrine active chemicals, in Great Lakes Areas of Concern

    EPA Science Inventory

    Chemical monitoring strategies are most effective for those chemicals whose hazards are well understood and for which sensitive and cost effective analytical methods are available. Unfortunately, such chemicals represent a minor fraction of those that may currently occur in the e...

  13. Cryptosporidium Propidium Monoazide-PCR, a Molecular Biology-Based Technique for Genotyping Viable Cryptosporidium Oocysts

    EPA Science Inventory

    Cryptosporidium is an important waterborne protozoan parasite that can cause severe diarrhea and death in the immunocompromised. Current methods to monitor for Cryptosporidium oocysts in water are microscopy-based USEPA Methods 1622 and 1623. These methods assess total levels o...

  14. SAMPLING LARGE RIVERS FOR ALGAE, BENTHIC MACROINVERTEBRATES AND FISH

    EPA Science Inventory

    Multiple projects are currently underway to increase our understanding of the effects of different sampling methods and designs used for the biological assessment and monitoring of large (boatable) rivers. Studies include methods used to assess fish, benthic macroinvertebrates, ...

  15. Building Energy Monitoring and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Tianzhen; Feng, Wei; Lu, Alison

    This project aimed to develop a standard methodology for building energy data definition, collection, presentation, and analysis; apply the developed methods to a standardized energy monitoring platform, including hardware and software, to collect and analyze building energy use data; and compile offline statistical data and online real-time data in both countries for fully understanding the current status of building energy use. This helps decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyzemore » good building energy data to provide valuable and actionable information for key stakeholders.« less

  16. Microelectrode-based technology for the detection of low levels of bacteria

    NASA Technical Reports Server (NTRS)

    Rogers, Tom D.; Hitchens, G. D.; Mishra, S. K.; Pierson, D. L.

    1992-01-01

    A microelectrode-based electrochemical detection method was used for quantitation of bacteria in water samples. The redox mediator, benzoquinone, was used to accept electrons from the bacterial metabolic pathway to create a flow of electrons by reducing the mediator. Electrochemical monitoring electrodes detected the reduced mediator as it diffused out of the cells and produced a small electrical current. By using a combination of microelectrodes and monitoring instrumentation, the cumulative current generated by a particular bacterial population could be monitored. Using commercially available components, an electrochemical detection system was assembled and tested to evaluate its potential as an emerging technology for rapid detection and quantitation of bacteria in water samples.

  17. Research on Damage Identification of Bridge Based on Digital Image Measurement

    NASA Astrophysics Data System (ADS)

    Liang, Yingjing; Huan, Shi; Tao, Weijun

    2017-12-01

    In recent years, the number of the damage bridge due to excessive deformation gradually increased, which caused significant property damage and casualties. Hence health monitoring and the damage detection of the bridge structure based on the deflection measurement are particularly important. The current conventional deflection measurement methods, such as total station, connected pipe, GPS, etc., have many shortcomings as low efficiency, heavy workload, low degree of automation, operating frequency and working time constrained. GPS has a low accuracy in the vertical displacement measurement and cannot meet the dynamic measured requirements of the current bridge engineering. This paper presents a bridge health monitoring and damage detection technology based on digital image measurement method in which the measurement accuracy is sub-millimeter level and can achieve the 24-hour automatic non-destructive monitoring for the deflection. It can be concluded from this paper that it is feasible to use digital image measurement method for identification of the damage in the bridge structure, because it has been validated by the theoretical analysis, the laboratory model and the application of the real bridge.

  18. [Current status and recommendations for intrapartum monitoring of fetal heart rate].

    PubMed

    Měchurová, A; Velebil, P; Hruban, L; Janků, P

    2016-04-01

    Monitoring of fetal heart rate is one of the basic components of obstetrical care, in which the cardiotocography remains the gold standard and screening method in early diagnosis of fetal hypoxia, even after introduction of other selective methods of intrauterine monitoring of fetal well-being. The review article is divided into several parts: pathophysiology of fetal oxygenation, fetal heart rate and changes of fetal hemodynamics, and rules for fetal heart rate auscultation. The main principles of cardiotocographic monitoring and evaluation of ante- and intrapartrum recordings according to the FIGO criteria from 1986 and evaluation of intrapartum recordings according to the 2015 FIGO recommendations are mentioned. At the end a comparative table of 1986 FIGO and 2015 FIGO criteria is presented. Review.

  19. Surface currents in the Bohai Sea derived from the Korean Geostationary Ocean Color Imager (GOCI)

    NASA Astrophysics Data System (ADS)

    Jiang, L.; Wang, M.

    2016-02-01

    The first geostationary ocean color satellite sensor, the Geostationary Ocean Color Imager (GOCI) onboard the Korean Communication, Ocean, and Meteorological Satellite can monitor and measure ocean phenomena over an area of 2500 × 2500 km2 around the western Pacific region centered at 36°N and 130°E. Hourly measurements during the day around 9:00 to 16:00 local time are a unique capability of GOCI to monitor ocean features of higher temporal variability. In this presentation, we show some recent results of GOCI-derived ocean surface currents in the Bohai Sea using the Maximum Cross-Correlation (MCC) feature tracking method and compare the results with altimetry-inversed tidal current observations produced from Oregon State University (OSU) Tidal Inversion Software (OTIS). The performance of the GOCI-based MCC method is assessed and the discrepancies between the GOCI- and OTIS-derived currents are evaluated. A series of sensitivity studies are conducted with images from various satellite products and of various time differences, MCC adjustable parameters, and influence from other forcings such as wind, to find the best setups for optimal MCC performance. Our results demonstrate that GOCI can effectively provide real-time monitoring of not only water optical, biological, and biogeochemical variability, but also the physical dynamics in the region.

  20. Method and system for operating an electric motor

    DOEpatents

    Gallegos-Lopez, Gabriel; Hiti, Silva; Perisic, Milun

    2013-01-22

    Methods and systems for operating an electric motor having a plurality of windings with an inverter having a plurality of switches coupled to a voltage source are provided. A first plurality of switching vectors is applied to the plurality of switches. The first plurality of switching vectors includes a first ratio of first magnitude switching vectors to second magnitude switching vectors. A direct current (DC) current associated with the voltage source is monitored during the applying of the first plurality of switching vectors to the plurality of switches. A second ratio of the first magnitude switching vectors to the second magnitude switching vectors is selected based on the monitoring of the DC current associated with the voltage source. A second plurality of switching vectors is applied to the plurality of switches. The second plurality of switching vectors includes the second ratio of the first magnitude switching vectors to the second magnitude switching vectors.

  1. A network security monitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heberlein, L.T.; Dias, G.V.; Levitt, K.N.

    1989-11-01

    The study of security in computer networks is a rapidly growing area of interest because of the proliferation of networks and the paucity of security measures in most current networks. Since most networks consist of a collection of inter-connected local area networks (LANs), this paper concentrates on the security-related issues in a single broadcast LAN such as Ethernet. Specifically, we formalize various possible network attacks and outline methods of detecting them. Our basic strategy is to develop profiles of usage of network resources and then compare current usage patterns with the historical profile to determine possible security violations. Thus, ourmore » work is similar to the host-based intrusion-detection systems such as SRI's IDES. Different from such systems, however, is our use of a hierarchical model to refine the focus of the intrusion-detection mechanism. We also report on the development of our experimental LAN monitor currently under implementation. Several network attacks have been simulated and results on how the monitor has been able to detect these attacks are also analyzed. Initial results demonstrate that many network attacks are detectable with our monitor, although it can surely be defeated. Current work is focusing on the integration of network monitoring with host-based techniques. 20 refs., 2 figs.« less

  2. Using Propidium Monoazide as an Enrichment Step to Remove Extraneous DMA and Non-Viable Organisms for Cryptosporidium Genotyping

    EPA Science Inventory

    Cryptosporidium is an important protozoan parasite that continues to cause waterborne disease outbreaks worldwide. Current methods to monitor for Cryptosporidium oocysts in water are microscopy-based USEPA Methods 1622 and 1623. These methods assess total levels of oocysts in s...

  3. A multiclass multiresidue LC-MS/MS method for analysis of veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    The increased efficiency permitted by multiclass, multiresidue methods has made such approaches very attractive to laboratories involved in monitoring veterinary drug residues in animal tissues. In this current work, evaluation of a multiclass multiresidue LC-MS/MS method in bovine kidney is describ...

  4. A FASTER METHOD OF MEASURING RECREATIONAL WATER QUALITY FOR BETTER PROTECTION OF SWIMMER'S HEALTH

    EPA Science Inventory

    Introduction

    Fecal indicator bacteria (FIB) are used to monitor recreational water quality worldwide. Current methods of measuring FIB require at least 24-hours for visible bacterial colonies to grow. We previously reported that a faster method (< 2 hours) of measuring FI...

  5. In-situ monitoring of H2O2 degradation by live cells using voltammetric detection in a lab-on-valve system.

    PubMed

    Lähdesmäki, Ilkka; Park, Young K; Carroll, Andrea D; Decuir, Michael; Ruzicka, Jaromir

    2007-08-01

    This paper describes a method for monitoring the degradation of hydrogen peroxide by cells immobilized on a beaded support. The detection is based on the voltammetric reduction of hydrogen peroxide on a mercury film working electrode, whilst combining the concept of sequential injection (SI) with the lab-on-valve (LOV) manifold allows the measurements to be carried out in real time and automatically, in well-defined conditions. The method is shown to be capable of simultaneously monitoring hydrogen peroxide in the 10-1000 microM range and oxygen in the 160-616 microM range. A correction algorithm has been used to ensure reliable H2O2 results in the presence of varying oxygen levels. The method has been successfully applied to monitoring the degradation of H2O2 by wild-type cells and by catalase-overexpressing mouse embryonic fibroblasts. Since the technique allows the monitoring of the initial response rate, it provides data not accessible by current methods that are end-point-based measurements.

  6. Smartphone electrographic monitoring for atrial fibrillation in acute ischemic stroke and transient ischemic attack.

    PubMed

    Tu, Hans T; Chen, Ziyuan; Swift, Corey; Churilov, Leonid; Guo, Ruibing; Liu, Xinfeng; Jannes, Jim; Mok, Vincent; Freedman, Ben; Davis, Stephen M; Yan, Bernard

    2017-10-01

    Rationale Paroxysmal atrial fibrillation is a common and preventable cause of devastating strokes. However, currently available monitoring methods, including Holter monitoring, cardiac telemetry and event loop recorders, have drawbacks that restrict their application in the general stroke population. AliveCor™ heart monitor, a novel device that embeds miniaturized electrocardiography (ECG) in a smartphone case coupled with an application to record and diagnose the ECG, has recently been shown to provide an accurate and sensitive single lead ECG diagnosis of atrial fibrillation. This device could be used by nurses to record a 30-s ECG instead of manual pulse taking and automatically provide a diagnosis of atrial fibrillation. Aims To compare the proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring with current standard practice. Sample size 296 Patients. Design Consecutive ischemic stroke and transient ischemic attack patients presenting to participating stroke units without known atrial fibrillation will undergo intermittent AliveCor™ ECG monitoring administered by nursing staff at the same frequency as the vital observations of pulse and blood pressure until discharge, in addition to the standard testing paradigm of each participating stroke unit to detect paroxysmal atrial fibrillation. Study outcome Proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring compared to 12-lead ECG, 24-h Holter monitoring and cardiac telemetry. Discussion Use of AliveCor™ heart monitor as part of routine stroke unit nursing observation has the potential to be an inexpensive non-invasive method to increase paroxysmal atrial fibrillation detection, leading to improvement in stroke secondary prevention.

  7. Developing Non-Targeted Measurement Methods to Characterize the Human Exposome

    EPA Science Inventory

    The exposome represents all exposures experienced by an individual during their lifetime. Registered chemicals currently number in the tens-of-thousands, and therefore comprise a significant portion of the human exposome. To date, quantitative monitoring methods have been develop...

  8. CHARACTERIZATION OF PRECURSOR 165 RRNA FOR AEROMONAS HYDROPHILA

    EPA Science Inventory

    Current strategies for monitoring drinking water quality involve culture-based methods to detect the presence of microbial indicators. However, these methods are insensitive when the organisms have undergone physiological changes such as injury and starvation that can occur in h...

  9. Content recognition for telephone monitoring

    NASA Astrophysics Data System (ADS)

    Wenndt, Stanley J.; Harris, David M.; Cupples, Edward J.

    2001-02-01

    This research began due to federal inmates abusing their telephone privileges by committing serious offenses such as murder, drug dealing, and fraud. On average, about 1000 calls are made per day at each federal prison with a peak of over 4000. Current monitoring capabilities are very man- intensive and only allow for about 2-3% monitoring of inmate telephone conversations. One of the main deficiencies identified by prison officials is the need to flag phone conversations pertaining to criminal activity. This research looks at two unique voice-processing methods to detect phone conversion pertaining to criminal activity. These two methods are digit string detection and whisper detection.

  10. Electric Fuel Pump Condition Monitor System Using Electricalsignature Analysis

    DOEpatents

    Haynes, Howard D [Knoxville, TN; Cox, Daryl F [Knoxville, TN; Welch, Donald E [Oak Ridge, TN

    2005-09-13

    A pump diagnostic system and method comprising current sensing probes clamped on electrical motor leads of a pump for sensing only current signals on incoming motor power, a signal processor having a means for buffering and anti-aliasing current signals into a pump motor current signal, and a computer having a means for analyzing, displaying, and reporting motor current signatures from the motor current signal to determine pump health using integrated motor and pump diagnostic parameters.

  11. Lithium-ion battery diagnostic and prognostic techniques

    DOEpatents

    Singh, Harmohan N.

    2009-11-03

    Embodiments provide a method and a system for determining cell imbalance condition of a multi-cell battery including a plurality of cell strings. To determine a cell imbalance condition, a charge current is applied to the battery and is monitored during charging. The charging time for each cell string is determined based on the monitor of the charge current. A charge time difference of any two cell strings in the battery is used to determine the cell imbalance condition by comparing with a predetermined acceptable charge time difference for the cell strings.

  12. Evaluation of 3 dental unit waterline contamination testing methods

    PubMed Central

    Porteous, Nuala; Sun, Yuyu; Schoolfield, John

    2015-01-01

    Previous studies have found inconsistent results from testing methods used to measure heterotrophic plate count (HPC) bacteria in dental unit waterline (DUWL) samples. This study used 63 samples to compare the results obtained from an in-office chairside method and 2 currently used commercial laboratory HPC methods (Standard Methods 9215C and 9215E). The results suggest that the Standard Method 9215E is not suitable for application to DUWL quality monitoring, due to the detection of limited numbers of heterotrophic organisms at the required 35°C incubation temperature. The results also confirm that while the in-office chairside method is useful for DUWL quality monitoring, the Standard Method 9215C provided the most accurate results. PMID:25574718

  13. Direct current electrical potential measurement of the growth of small cracks

    NASA Technical Reports Server (NTRS)

    Gangloff, Richard P.; Slavik, Donald C.; Piascik, Robert S.; Van Stone, Robert H.

    1992-01-01

    The analytical and experimental aspects of the direct-current electrical potential difference (dcEPD) method for continuous monitoring of the growth kinetics of short (50 to 500 microns) fatigue cracks are reviewed, and successful applications of the deEPD method to study fatigue crack propagation in a variety of metallic alloys exposed to various environments are described. Particular attention is given to the principle of the dcEPD method, the analytical electrical potential calibration relationships, and the experimental procedures and equipment.

  14. Microbial Monitoring of Common Opportunistic Pathogens by Comparing Multiple Real-time PCR Platforms for Potential Space Applications

    NASA Technical Reports Server (NTRS)

    Roman, Monserrate C.; Jones, Kathy U.; Oubre, Cherie M.; Castro, Victoria; Ott, Mark C.; Birmele, Michele; Venkateswaran, Kasthuri J.; Vaishampayan, Parag A.

    2013-01-01

    Current methods for microbial detection: a) Labor & time intensive cultivation-based approaches that can fail to detect or characterize all cells present. b) Requires collection of samples on orbit and transportation back to ground for analysis. Disadvantages to current detection methods: a) Unable to perform quick and reliable detection on orbit. b) Lengthy sampling intervals. c) No microbe identification.

  15. Method and system for controlling a permanent magnet machine during fault conditions

    DOEpatents

    Krefta, Ronald John; Walters, James E.; Gunawan, Fani S.

    2004-05-25

    Method and system for controlling a permanent magnet machine driven by an inverter is provided. The method allows for monitoring a signal indicative of a fault condition. The method further allows for generating during the fault condition a respective signal configured to maintain a field weakening current even though electrical power from an energy source is absent during said fault condition. The level of the maintained field-weakening current enables the machine to operate in a safe mode so that the inverter is protected from excess voltage.

  16. Experimental Test of Data Analysis Methods from Staggered Pair X-ray Beam Position Monitors at Bending Magnet Beamlines

    NASA Astrophysics Data System (ADS)

    Buth, G.; Huttel, E.; Mangold, S.; Steininger, R.; Batchelor, D.; Doyle, S.; Simon, R.

    2013-03-01

    Different methods have been proposed to calculate the vertical position of the photon beam centroid from the four blade currents of staggered pair X-ray beam position monitors (XBPMs) at bending magnet beamlines since they emerged about 15 years ago. The original difference-over-sum method introduced by Peatman and Holldack is still widely used, even though it has been proven to be rather inaccurate at large beam displacements. By systematically generating bumps in the electron orbit of the ANKA storage ring and comparing synchronized data from electron BPMs and XBPM blade currents, we have been able to show that the log-ratio method by S. F. Lin, B.G. Sun et al. is superior (meaning the characteristic being closer to linear) to the ratio method, which in turn is superior to the difference over sum method. These findings are supported by simulations of the XBPM response to changes of the beam centroid. The heuristic basis for each of the methods is investigated. The implications on using XBPM readings for orbit correction are discussed

  17. Ion current detector for high pressure ion sources for monitoring separations

    DOEpatents

    Smith, R.D.; Wahl, J.H.; Hofstadler, S.A.

    1996-08-13

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source. 7 figs.

  18. Ion current detector for high pressure ion sources for monitoring separations

    DOEpatents

    Smith, Richard D.; Wahl, Jon H.; Hofstadler, Steven A.

    1996-01-01

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source.

  19. Gear wear monitoring by modulation signal bispectrum based on motor current signal analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Ruiliang; Gu, Fengshou; Mansaf, Haram; Wang, Tie; Ball, Andrew D.

    2017-09-01

    Gears are important mechanical components for power transmissions. Tooth wear is one of the most common failure modes, which can present throughout a gear's lifetime. It is significant to accurately monitor gear wear progression in order to take timely predictive maintenances. Motor current signature analysis (MCSA) is an effective and non-intrusive approach which is able to monitor faults from both electrical and mechanical systems. However, little research has been reported in monitoring the gear wear and estimating its severity based on MCSA. This paper presents a novel gear wear monitoring method through a modulation signal bispectrum based motor current signal analysis (MSB-MCSA). For a steady gear transmission, it is inevitable to exist load and speed oscillations due to various errors including wears. These oscillations can induce small modulations in the current signals of the driving motor. MSB is particularly effective in characterising such small modulation signals. Based on these understandings, the monitoring process was implemented based on the current signals from a run-to-failure test of an industrial two stages helical gearbox under a moderate accelerated fatigue process. At the initial operation of the test, MSB analysis results showed that the peak values at the bifrequencies of gear rotations and the power supply can be effective monitoring features for identifying faulty gears and wear severity as they exhibit agreeable changes with gear loads. A monotonically increasing trend established by these features allows a clear indication of the gear wear progression. The dismantle inspection at 477 h of operation, made when one of the monitored features is about 123% higher than its baseline, has found that there are severe scuffing wear marks on a number of tooth surfaces on the driving gear, showing that the gear endures a gradual wear process during its long test operation. Therefore, it is affirmed that the MSB-MSCA approach proposed is reliable and accurate for monitoring gear wear deterioration.

  20. Embedded Reasoning Supporting Aerospace IVHM

    DTIC Science & Technology

    2007-01-01

    c method (BIT or health assessment algorithm) which the monitoring diagnostic relies on input information tics and Astronautics In the diagram...viewing of the current health state of all monitored subsystems, while also providing a means to probe deeper in the event anomalous operation is...seeks to integrate detection , diagnostic, and prognostic capabilities with a hierarchical diagnostic reasoning architecture into a single

  1. DEVELOP METHOD FOR THE DETERMINATION OF DISINFECTION BY-PRODUCT FORMATION POTENTIAL (DBP-FP) AND INSTRUMENT DETECTION SYSTEM FOR MONITORING DBP-FP IN DRINKING WATER

    EPA Science Inventory

    EPA requires drinking water utilities to monitor source water to determine the need for treatment to remove the precursors (natural organic matter {NOM}) of disinfection by-products (DBPs). Currently, drinking water utilities use total organic carbon (TOC), dissolved organic car...

  2. Integrated sUAS Greenhouse Gas Measurements and Imagery for Land Use Emissions Monitoring

    NASA Astrophysics Data System (ADS)

    Barbieri, L.; Wyngaard, J.; Galford, G. L.; Adair, C.

    2016-12-01

    Agriculture, Forestry and Other Land Uses (AFOLU) constitute the second largest anthropogenic source of greenhouse gas (GHG) emissions globally. Agriculture is the dominant source of emissions within that sector. There are a variety of agricultural land management strategies that can be implemented to reduce GHG emissions, but determining the best strategies is challenging. Emissions estimates are currently derived from GHG monitoring methods (e.g., static chambers, eddy flux towers) that are time and labor intensive, expensive, and use in-situ equipment. These methods lack the flexible, spatio-temporal monitoring necessary to reduce the high uncertainty in regional GHG emissions estimates. Small Unmanned Aerial Systems (sUAS) provide the rapid response data collection needed to monitor important field management events (e.g., manure spreading). Further, the ease of deployment of sUAS makes monitoring large regional extents over full-seasons more viable. To our knowledge, we present the first integration of sUAS remotely sensed imagery and GHG concentrations in agriculture and land use monitoring. We have developed and tested open-source hardware and software utilizing low-cost equipment (e.g., NDIR gas sensors and Canon cameras). Initial results show agreement with more traditional, proprietary equipment but at a fraction of the costs. Here we present data from test flights over agricultural areas under various management practices. The suite of data includes sUAS overpasses for imagery and CO2 concentration measurements, paired with field-based GHG measurements (static chambers). We have developed a set of best practices for sUAS data collection (e.g., time of day effects variability in localized atmospheric GHG concentrations) and discuss currently known challenges (e.g., accounting for external environmental factors such as wind speed). We present results on all sUAS GHG sampling methods paired with imagery and simultaneous static chamber monitoring for a comprehensive assessment of methods for use in GHG emission hotspot detection across landscapes.

  3. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    PubMed

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  4. Neutral beam monitoring

    DOEpatents

    Fink, Joel H.

    1981-08-18

    Method and apparatus for monitoring characteristics of a high energy neutral beam. A neutral beam is generated by passing accelerated ions through a walled cell containing a low energy neutral gas, such that charge exchange neutralizes the high energy ion beam. The neutral beam is monitored by detecting the current flowing through the cell wall produced by low energy ions which drift to the wall after the charge exchange. By segmenting the wall into radial and longitudinal segments various beam conditions are further identified.

  5. Laser-induced breakdown spectroscopy application in environmental monitoring of water quality: a review.

    PubMed

    Yu, Xiaodong; Li, Yang; Gu, Xiaofeng; Bao, Jiming; Yang, Huizhong; Sun, Li

    2014-12-01

    Water quality monitoring is a critical part of environmental management and protection, and to be able to qualitatively and quantitatively determine contamination and impurity levels in water is especially important. Compared to the currently available water quality monitoring methods and techniques, laser-induced breakdown spectroscopy (LIBS) has several advantages, including no need for sample pre-preparation, fast and easy operation, and chemical free during the process. Therefore, it is of great importance to understand the fundamentals of aqueous LIBS analysis and effectively apply this technique to environmental monitoring. This article reviews the research conducted on LIBS analysis for liquid samples, and the article content includes LIBS theory, history and applications, quantitative analysis of metallic species in liquids, LIBS signal enhancement methods and data processing, characteristics of plasma generated by laser in water, and the factors affecting accuracy of analysis results. Although there have been many research works focusing on aqueous LIBS analysis, detection limit and stability of this technique still need to be improved to satisfy the requirements of environmental monitoring standard. In addition, determination of nonmetallic species in liquid by LIBS is equally important and needs immediate attention from the community. This comprehensive review will assist the readers to better understand the aqueous LIBS technique and help to identify current research needs for environmental monitoring of water quality.

  6. Rapid extraction of virus-contaminated hemocytes from oysters

    USDA-ARS?s Scientific Manuscript database

    Rapid viral detection methods are necessary to employ diagnostic testing for viral contamination in shellfish to prevent and control foodborne illness. Current shellfish viral RNA extraction methods, which are time-consuming and not applicable for routine monitoring, require the testing of whole or ...

  7. CHARACTERIZATION OF PRECURSOR FOR 16S rRNA FOR AEROMONAS HYDROPHILA

    EPA Science Inventory

    Current strategies for monitoring drinking water quality involve culture-based methods to detect the presence of microbial indicators. However, these methods are insensitive when the organisms have undergone physiological changes such as injury and starvation that can occur in h...

  8. Monitoring therapeutic anticoagulation with low molecular weight heparins: is it useful or misleading?

    PubMed

    Hammerstingl, C

    2008-10-01

    Weight adapted low molecular weight heparin (LMWH) treatment is recommended as initial anticoagulant therapy of deep vein thrombosis, pulmonary embolism, in patients with myocardial ischemia or when oral anticoagulation (OAC) must be interrupted peri- operatively. Traditionally unfractioned heparin (UFH) was used as standard short acting anticoagulant, with the therapy monitored by frequent laboratory testing. Currently LMWH have broadly replaced UFH as first- choice anticoagulant due to more preferable pharmacokinetics and a better safety profile. Therapeutic anticoagulation with LMWH can be achieved by subcutaneous weight adapted application and measurement of anti-factor Xa- activity (anti-Xa) has been established as gold standard for LMWH- monitoring. However, since almost all LMWH dosing regimens have been developed empirically without laboratory monitoring, there is still a debate ongoing about the usefulness and impact of anti-Xa-testing. Data are lacking that prove a clear correlation between obtained levels of anti-Xa and the patients' clinical outcome. Newer methods have been developed aiming to determine a broader spectrum of LMWH depending anticoagulant activity. Even though there are some promising preliminary results, these alternative methods are not ready for routine clinical use yet. Nevertheless, current guidelines advise determination of anti-Xa in special patient populations with markedly altered LMWH metabolism or to exclude residual LMWH- activity before surgery at very high risk of bleeding. The aim of this article is to review critically the usefulness of anti- Xa guidance of LMWH- therapy and to give new perspectives on upcoming methods of LMWH- monitoring.

  9. 47 CFR 73.1820 - Station log.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... values): (A) Common point current. (B) When the operating power is determined by the indirect method, the efficiency factor F and either the product of the final amplifier input voltage and current or the calculated antenna input power. See § 73.51(e). (C) Antenna monitor phase or phase deviation indications. (D) Antenna...

  10. Real Time Network Monitoring and Reporting System

    ERIC Educational Resources Information Center

    Massengale, Ricky L., Sr.

    2009-01-01

    With the ability of modern system developers to develop intelligent programs that allows machines to learn, modify and evolve themselves, current trends of reactionary methods to detect and eradicate malicious software code from infected machines is proving to be too costly. Addressing malicious software after an attack is the current methodology…

  11. Systems, methods and computer-readable media for modeling cell performance fade of rechargeable electrochemical devices

    DOEpatents

    Gering, Kevin L

    2013-08-27

    A system includes an electrochemical cell, monitoring hardware, and a computing system. The monitoring hardware periodically samples performance characteristics of the electrochemical cell. The computing system determines cell information from the performance characteristics of the electrochemical cell. The computing system also develops a mechanistic level model of the electrochemical cell to determine performance fade characteristics of the electrochemical cell and analyzing the mechanistic level model to estimate performance fade characteristics over aging of a similar electrochemical cell. The mechanistic level model uses first constant-current pulses applied to the electrochemical cell at a first aging period and at three or more current values bracketing a first exchange current density. The mechanistic level model also is based on second constant-current pulses applied to the electrochemical cell at a second aging period and at three or more current values bracketing the second exchange current density.

  12. Integrating Sensor Monitoring Technology into the Current Air Pollution Regulatory Support Paradigm: Practical Considerations

    EPA Science Inventory

    The US Environmental Protection Agency (EPA) along with state, local, and tribal governments operate Federal Reference Method (FRM) and Federal Equivalent Method (FEM) instruments to assess compliance with US air pollution standards designed to protect human and ecosystem health....

  13. RAPID HEALTH-BASED METHOD FOR MEASURING MICROBIAL INDICATORS OF RECREATIONAL WATER QUALITY

    EPA Science Inventory

    Because the currently approved cultural methods for monitoring indicator bacteria in recreational water require 24 hours to produce results, the public may be exposed to potentially contaminated water before the water has been identified as hazardous. This project was initiated t...

  14. A Procedural Electroencephalogram Simulator for Evaluation of Anesthesia Monitors.

    PubMed

    Petersen, Christian Leth; Görges, Matthias; Massey, Roslyn; Dumont, Guy Albert; Ansermino, J Mark

    2016-11-01

    Recent research and advances in the automation of anesthesia are driving the need to better understand electroencephalogram (EEG)-based anesthesia end points and to test the performance of anesthesia monitors. This effort is currently limited by the need to collect raw EEG data directly from patients. A procedural method to synthesize EEG signals was implemented in a mobile software application. The application is capable of sending the simulated signal to an anesthesia depth of hypnosis monitor. Systematic sweeps of the simulator generate functional monitor response profiles reminiscent of how network analyzers are used to test electronic components. Three commercial anesthesia monitors (Entropy, NeuroSENSE, and BIS) were compared with this new technology, and significant response and feature variations between the monitor models were observed; this includes reproducible, nonmonotonic apparent multistate behavior and significant hysteresis at light levels of anesthesia. Anesthesia monitor response to a procedural simulator can reveal significant differences in internal signal processing algorithms. The ability to synthesize EEG signals at different anesthetic depths potentially provides a new method for systematically testing EEG-based monitors and automated anesthesia systems with all sensor hardware fully operational before human trials.

  15. Current methods of monitoring radiation exposure from CT.

    PubMed

    Talati, Ronak K; Dunkin, Jared; Parikh, Shrujal; Moore, William H

    2013-09-01

    Increased public and regulatory scrutiny of imaging-related radiation exposure requires familiarity with current dose-monitoring techniques and best practices. CT-related ionizing radiation exposure has been cited as the largest and fastest growing source of population-wide iatrogenic ionizing radiation exposure. Upcoming federal regulations require imaging centers to familiarize themselves with available dose-monitoring techniques and implement comprehensive strategies to track patient dose, with particular emphasis on CT. Because of institution-specific and vendor-specific technologies, there are significant barriers to adoption and implementation. In this article, the authors outline the core components of a universal dose-monitoring strategy and detail a few of the many available commercial platforms. In addition, the authors introduce a cloud-based hybrid model dose-tracking system with the goal of rapid implementation, multicenter scalability, real-time dose feedback for technologists, cumulative dose monitoring, and optional dose communication to patients and into the record; doing so results in improved patient loyalty, referring physician satisfaction, and opportunity for repeat business. Copyright © 2013 American College of Radiology. All rights reserved.

  16. Exploring infrared sensoring for real time welding defects monitoring in GTAW.

    PubMed

    Alfaro, Sadek C A; Franco, Fernand Díaz

    2010-01-01

    This paper presents an evaluation of an infrared sensor for monitoring the welding pool temperature in a Gas Tungsten Arc Welding (GTAW) process. The purpose of the study is to develop a real time system control. It is known that the arc welding pool temperature is related to the weld penetration depth; therefore, by monitoring the temperature, the arc pool temperature and penetration depth are also monitored. Various experiments were performed; in some of them the current was varied and the temperature changes were registered, in others, defects were induced throughout the path of the weld bead for a fixed current. These simulated defects resulted in abrupt changes in the average temperature values, thus providing an indication of the presence of a defect. The data has been registered with an acquisition card. To identify defects in the samples under infrared emissions, the timing series were analyzed through graphics and statistic methods. The selection of this technique demonstrates the potential for infrared emission as a welding monitoring parameter sensor.

  17. Exploring Infrared Sensoring for Real Time Welding Defects Monitoring in GTAW

    PubMed Central

    Alfaro, Sadek C. A.; Franco, Fernand Díaz

    2010-01-01

    This paper presents an evaluation of an infrared sensor for monitoring the welding pool temperature in a Gas Tungsten Arc Welding (GTAW) process. The purpose of the study is to develop a real time system control. It is known that the arc welding pool temperature is related to the weld penetration depth; therefore, by monitoring the temperature, the arc pool temperature and penetration depth are also monitored. Various experiments were performed; in some of them the current was varied and the temperature changes were registered, in others, defects were induced throughout the path of the weld bead for a fixed current. These simulated defects resulted in abrupt changes in the average temperature values, thus providing an indication of the presence of a defect. The data has been registered with an acquisition card. To identify defects in the samples under infrared emissions, the timing series were analyzed through graphics and statistic methods. The selection of this technique demonstrates the potential for infrared emission as a welding monitoring parameter sensor. PMID:22219697

  18. Detecting Cognitive Stress and Impairment Using Keystroke and Linguistic Features of Typed Text: Toward a Method for Continuous Monitoring of Cognitive Status

    ERIC Educational Resources Information Center

    Vizer, Lisa Michele

    2013-01-01

    Systems that can detect cognitive decline or harmful levels of stress could assist users in managing their stress and health. However, current assessments are often obtrusive or require specialized equipment, and not suited to continuous monitoring of cognitive status. This research leverages attributes of everyday keyboard interactions to…

  19. An assessment of the performance of Monitor for AeRosols and GAses in ambient air (MARGA): a semi-continuous method for soluble compounds

    EPA Science Inventory

    Ambient air monitoring as part of the U.S. Environmental Protection Agency’s (U.S. EPA’s) Clean Air Status and Trends Network (CASTNet) currently uses filter packs to measure weekly integrated concentrations. The U.S. EPA is interested in supplementing CASTNet with semi-continuou...

  20. PM2.5 Monitors in New England | Air Quality Planning Unit ...

    EPA Pesticide Factsheets

    2017-04-10

    The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.

  1. Network based sky Brightness Monitor

    NASA Astrophysics Data System (ADS)

    McKenna, Dan; Pulvermacher, R.; Davis, D. R.

    2009-01-01

    We have developed and are currently testing an autonomous 2 channel photometer designed to measure the night sky brightness in the visual wavelengths over a multi-year campaign. The photometer uses a robust silicon sensor filtered with Hoya CM500 glass. The Sky brightness is measured every minute at two elevation angles typically zenith and 20 degrees to monitor brightness and transparency. The Sky Brightness monitor consists of two units, the remote photometer and a network interface. Currently these devices use 2.4 Ghz transceivers with a free space range of 100 meters. The remote unit is battery powered with day time recharging using a solar panel. Data received by the network interface transmits data via standard POP Email protocol. A second version is under development for radio sensitive areas using an optical fiber for data transmission. We will present the current comparison with the National Park Service sky monitoring camera. We will also discuss the calibration methods used for standardization and temperature compensation. This system is expected to be deployed in the next year and be operated by the International Dark Sky Association SKYMONITOR project.

  2. Distributed measurement of high electric current by means of polarimetric optical fiber sensor.

    PubMed

    Palmieri, Luca; Sarchi, Davide; Galtarossa, Andrea

    2015-05-04

    A novel distributed optical fiber sensor for spatially resolved monitoring of high direct electric current is proposed and analyzed. The sensor exploits Faraday rotation and is based on the polarization analysis of the Rayleigh backscattered light. Preliminary laboratory tests, performed on a section of electric cable for currents up to 2.5 kA, have confirmed the viability of the method.

  3. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    In the history of manned spaceflight, environmental monitoring has relied heavily on archival sampling. For short missions, this type of sample collection was sufficient; returned samples provided a snapshot of the presence of chemical and biological contaminants in the spacecraft air and water. However, with the construction of the International Space Station (ISS) and the subsequent extension of mission durations, soon to be up to one year, the need for enhanced, real-time environmental monitoring became more pressing. The past several years have seen the implementation of several real-time monitors aboard the ISS, complemented with reduced archival sampling. The station air is currently monitored for volatile organic compounds (VOCs) using gas chromatography-differential mobility spectrometry (Air Quality Monitor [AQM]). The water on ISS is analyzed to measure total organic carbon and biocide concentrations using the Total Organic Carbon Analyzer (TOCA) and the Colorimetric Water Quality Monitoring Kit (CWQMK), respectively. The current air and water monitors provide important data, but the number and size of the different instruments makes them impractical for future exploration missions. It is apparent that there is still a need for improvements in environmental monitoring capabilities. One such improvement could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for target compounds present in air samples, and many of the compounds are also targets for water quality monitoring, this instrument provides a logical starting point to evaluate the feasibility of this approach. In this presentation, we will discuss our recent studies aimed at determining an appropriate method for introducing VOCs from water samples into the gas phase and our current work, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target analytes at the relevant concentrations at which they are routinely detected in archival water samples from the ISS.

  4. Remote sensing of ocean currents

    NASA Technical Reports Server (NTRS)

    Goldstein, R. M.; Zebker, H. A.; Barnett, T. P.

    1989-01-01

    A method of remotely measuring near-surface ocean currents with a synthetic aperture radar (SAR) is described. The apparatus consists of a single SAR transmitter and two receiving antennas. The phase difference between SAR image scenes obtained from the antennas forms an interferogram that is directly proportional to the surface current. The first field test of this technique against conventional measurements gives estimates of mean currents accurate to order 20 percent, that is, root-mean-square errors of 5 to 10 centimeters per second in mean flows of 27 to 56 centimeters per second. If the full potential of the method could be realized with spacecraft, then it might be possible to routinely monitor the surface currents of the world's oceans.

  5. The Enterococcus QPCR Method for Recreational Water Quality Testing: Testing Background, Performance and Issues

    EPA Science Inventory

    Currently accepted culture-based monitoring methods for fecal indicator bacteria in surface waters take at least 24 hr to determine if unacceptable levels of fecal pollution have reached our recreational beaches. During this waiting period changing water conditions may result eit...

  6. Current issues involving screening and identification of chemical contaminants in foods by mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Although quantitative analytical methods must be empirically validated prior to their actual use in a variety of applications, including regulatory monitoring of chemical adulterants in foods, validation of qualitative method performance for the analytes and matrices of interest is frequently ignore...

  7. Method to Select Metropolitan Areas of Epidemiologic Interest for Enhanced Air Quality Monitoring

    EPA Science Inventory

    The U.S. Environmental Protection Agency’s current Speciation Trends Network (STN) covers most major U.S. metropolitan areas and a wide range of particulate matter (PM) constituents and gaseous co-pollutants. However, using filter-based methods, most PM constituents are measured ...

  8. USE OF A MOLECULAR PROBE ASSAY FOR MONITORING SALMONELLA SPP. IN BIOSOLIDS SAMPLES

    EPA Science Inventory

    Current federal regulations (40 CFR 503) require enumeration of fecal coliform or salmonellae prior to land application of biosolids. This regulation specifies use of enumeration methods included in "Standard methods for the Examination of Water and Wastewater 18th Edition," (SM)...

  9. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...

  10. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  11. Multi-channel electrical impedance tomography for regional tissue hydration monitoring.

    PubMed

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-06-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical settings for helping optimize patient fluid management during hemodialysis as well as for home monitoring of patients with congestive heart failure, chronic kidney disease, diabetes and other diseases with peripheral edema symptoms.

  12. Measuring skin conductance over clothes.

    PubMed

    Hong, Ki Hwan; Lee, Seung Min; Lim, Yong Gyu; Park, Kwang Suk

    2012-11-01

    We propose a new method that measures skin conductance over clothes to nonintrusively monitor the changes in physiological conditions affecting skin conductance during daily activities. We selected the thigh-to-thigh current path and used an indirectly coupled 5-kHz AC current for the measurement. While varying the skin conductance by the Valsalva maneuver method, the results were compared with the traditional galvanic skin response (GSR) measured directly from the fingers. Skin conductance measured using a 5-kHz current displayed a highly negative correlation with the traditional GSR and the current measured over clothes reflected the rate of change of the conductance of the skin beneath.

  13. Visual Sensing for Urban Flood Monitoring

    PubMed Central

    Lo, Shi-Wei; Wu, Jyh-Horng; Lin, Fang-Pang; Hsu, Ching-Han

    2015-01-01

    With the increasing climatic extremes, the frequency and severity of urban flood events have intensified worldwide. In this study, image-based automated monitoring of flood formation and analyses of water level fluctuation were proposed as value-added intelligent sensing applications to turn a passive monitoring camera into a visual sensor. Combined with the proposed visual sensing method, traditional hydrological monitoring cameras have the ability to sense and analyze the local situation of flood events. This can solve the current problem that image-based flood monitoring heavily relies on continuous manned monitoring. Conventional sensing networks can only offer one-dimensional physical parameters measured by gauge sensors, whereas visual sensors can acquire dynamic image information of monitored sites and provide disaster prevention agencies with actual field information for decision-making to relieve flood hazards. The visual sensing method established in this study provides spatiotemporal information that can be used for automated remote analysis for monitoring urban floods. This paper focuses on the determination of flood formation based on image-processing techniques. The experimental results suggest that the visual sensing approach may be a reliable way for determining the water fluctuation and measuring its elevation and flood intrusion with respect to real-world coordinates. The performance of the proposed method has been confirmed; it has the capability to monitor and analyze the flood status, and therefore, it can serve as an active flood warning system. PMID:26287201

  14. Optimization of a Coastal Environmental Monitoring Network Based on the Kriging Method: A Case Study of Quanzhou Bay, China

    PubMed Central

    Chen, Kai; Ni, Minjie; Wang, Jun; Huang, Dongren; Chen, Huorong; Wang, Xiao; Liu, Mengyang

    2016-01-01

    Environmental monitoring is fundamental in assessing environmental quality and to fulfill protection and management measures with permit conditions. However, coastal environmental monitoring work faces many problems and challenges, including the fact that monitoring information cannot be linked up with evaluation, monitoring data cannot well reflect the current coastal environmental condition, and monitoring activities are limited by cost constraints. For these reasons, protection and management measures cannot be developed and implemented well by policy makers who intend to solve this issue. In this paper, Quanzhou Bay in southeastern China was selected as a case study; and the Kriging method and a geographic information system were employed to evaluate and optimize the existing monitoring network in a semienclosed bay. This study used coastal environmental monitoring data from 15 sites (including COD, DIN, and PO4-P) to adequately analyze the water quality from 2009 to 2012 by applying the Trophic State Index. The monitoring network in Quanzhou Bay was evaluated and optimized, with the number of sites increased from 15 to 24, and the monitoring precision improved by 32.9%. The results demonstrated that the proposed advanced monitoring network optimization was appropriate for environmental monitoring in Quanzhou Bay. It might provide technical support for coastal management and pollutant reduction in similar areas. PMID:27777951

  15. Optimization of a Coastal Environmental Monitoring Network Based on the Kriging Method: A Case Study of Quanzhou Bay, China.

    PubMed

    Chen, Kai; Ni, Minjie; Cai, Minggang; Wang, Jun; Huang, Dongren; Chen, Huorong; Wang, Xiao; Liu, Mengyang

    2016-01-01

    Environmental monitoring is fundamental in assessing environmental quality and to fulfill protection and management measures with permit conditions. However, coastal environmental monitoring work faces many problems and challenges, including the fact that monitoring information cannot be linked up with evaluation, monitoring data cannot well reflect the current coastal environmental condition, and monitoring activities are limited by cost constraints. For these reasons, protection and management measures cannot be developed and implemented well by policy makers who intend to solve this issue. In this paper, Quanzhou Bay in southeastern China was selected as a case study; and the Kriging method and a geographic information system were employed to evaluate and optimize the existing monitoring network in a semienclosed bay. This study used coastal environmental monitoring data from 15 sites (including COD, DIN, and PO 4 -P) to adequately analyze the water quality from 2009 to 2012 by applying the Trophic State Index. The monitoring network in Quanzhou Bay was evaluated and optimized, with the number of sites increased from 15 to 24, and the monitoring precision improved by 32.9%. The results demonstrated that the proposed advanced monitoring network optimization was appropriate for environmental monitoring in Quanzhou Bay. It might provide technical support for coastal management and pollutant reduction in similar areas.

  16. Research on the optimization of air quality monitoring station layout based on spatial grid statistical analysis method.

    PubMed

    Li, Tianxin; Zhou, Xing Chen; Ikhumhen, Harrison Odion; Difei, An

    2018-05-01

    In recent years, with the significant increase in urban development, it has become necessary to optimize the current air monitoring stations to reflect the quality of air in the environment. Highlighting the spatial representation of some air monitoring stations using Beijing's regional air monitoring station data from 2012 to 2014, the monthly mean particulate matter concentration (PM10) in the region was calculated and through the IDW interpolation method and spatial grid statistical method using GIS, the spatial distribution of PM10 concentration in the whole region was deduced. The spatial distribution variation of districts in Beijing using the gridding model was performed, and through the 3-year spatial analysis, PM10 concentration data including the variation and spatial overlay (1.5 km × 1.5 km cell resolution grid), the spatial distribution result obtained showed that the total PM10 concentration frequency variation exceeded the standard. It is very important to optimize the layout of the existing air monitoring stations by combining the concentration distribution of air pollutants with the spatial region using GIS.

  17. Correction Methods for Organic Carbon Artifacts when Using Quartz-Fiber Filters in Large Particulate Matter Monitoring Networks: The Regression Method and Other Options

    EPA Science Inventory

    Sampling and handling artifacts can bias filter-based measurements of particulate organic carbon (OC). Several measurement-based methods for OC artifact reduction and/or estimation are currently used in research-grade field studies. OC frequently is not artifact-corrected in larg...

  18. Some Inspection Methods for Quality Control and In-service Inspection of GLARE

    NASA Astrophysics Data System (ADS)

    Sinke, J.

    2003-07-01

    Quality control of materials and structures is an important issue, also for GLARE. During the manufacturing stage the processes and materials should be monitored and checked frequently in order to obtain a qualified product. During the operation of the aircraft, frequent monitoring and inspections are performed to maintain the quality at a prescribed level. Therefore, in-service inspection methods are applied, and when necessary repair activities are conducted. For the quality control of the GLARE panels and components during manufacturing, the C-scan method proves to be an effective tool. For in-service inspection the Eddy Current Method is one of the suitable options. In this paper a brief overview is presented of both methods and their application on GLARE products.

  19. A review of microdialysis coupled to microchip electrophoresis for monitoring biological events

    PubMed Central

    Saylor, Rachel A.; Lunte, Susan M.

    2015-01-01

    Microdialysis is a powerful sampling technique that enables monitoring of dynamic processes in vitro and in vivo. The combination of microdialysis with chromatographic or electrophoretic methods yields along with selective detection methods yields a “separation-based sensor” capable of monitoring multiple analytes in near real time. Analysis of microdialysis samples requires techniques that are fast (<1 min), have low volume requirements (nL–pL), and, ideally, can be employed on-line. Microchip electrophoresis fulfills these requirements and also permits the possibility of integrating sample preparation and manipulation with detection strategies directly on-chip. Microdialysis coupled to microchip electrophoresis has been employed for monitoring biological events in vivo and in vitro. This review discusses technical considerations for coupling microdialysis sampling and microchip electrophoresis, including various interface designs, and current applications in the field. PMID:25637011

  20. [Bioimpedance means of skin condition monitoring during therapeutic and cosmetic procedures].

    PubMed

    Alekseenko, V A; Kus'min, A A; Filist, S A

    2008-01-01

    Engineering and technological problems of bioimpedance skin surface mapping are considered. A typical design of a device based on a PIC 16F microcontroller is suggested. It includes a keyboard, LCD indicator, probing current generator with programmed frequency tuning, and units for probing current monitoring and bioimpedance measurement. The electrode matrix of the device is constructed using nanotechnology. A microcontroller-controlled multiplexor provides scanning of interelectrode impedance, which makes it possible to obtain the impedance image of the skin surface under the electrode matrix. The microcontroller controls the probing signal generator frequency and allows layer-by-layer images of skin under the electrode matrix to be obtained. This makes it possible to use reconstruction tomography methods for analysis and monitoring of the skin condition during therapeutic and cosmetic procedures.

  1. Method development and qualification of capillary zone electrophoresis for investigation of therapeutic monoclonal antibody quality.

    PubMed

    Suba, Dávid; Urbányi, Zoltán; Salgó, András

    2016-10-01

    Capillary electrophoresis techniques are widely used in the analytical biotechnology. Different electrophoretic techniques are very adequate tools to monitor size-and charge heterogenities of protein drugs. Method descriptions and development studies of capillary zone electrophoresis (CZE) have been described in literature. Most of them are performed based on the classical one-factor-at-time (OFAT) approach. In this study a very simple method development approach is described for capillary zone electrophoresis: a "two-phase-four-step" approach is introduced which allows a rapid, iterative method development process and can be a good platform for CZE method. In every step the current analytical target profile and an appropriate control strategy were established to monitor the current stage of development. A very good platform was established to investigate intact and digested protein samples. Commercially available monoclonal antibody was chosen as model protein for the method development study. The CZE method was qualificated after the development process and the results were presented. The analytical system stability was represented by the calculated RSD% value of area percentage and migration time of the selected peaks (<0.8% and <5%) during the intermediate precision investigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. RAPID HEALTH-BASED METHOD FOR MEASURING MICROBIAL INDICATORS OF RECREATIONAL WATER QUALITY - 2006 EPA SCIENCE FORUM

    EPA Science Inventory

    Because the current approved cultural methods for monitoring indicator bacteria in recreational water require 24 hours to produce results, the public may be exposed to potentially contaminated water before the water has been identified as hazardous. This project was initiated to...

  3. Time-resolved luminescence screening method for enrofloxacin in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods currently used in the U.S. for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay ...

  4. The MOST - Monitor for Oxygenation of Surface and Tissue.

    DTIC Science & Technology

    1995-10-01

    CAT Reduce need for ICU, low risk groups Central nursing station Office procedures: Dentistry , Endoscopy Monitoring spinal or epidural narcotics Home...obtainable by using laser Doppler methods (Wickramasinghe et al., 1994; Liepsch et al., 1993; Mendelson, Ochs, 1988). While many parameters beyond oxygenation...blood flow include laser Doppler flowmetry sys- tems which are currently commercially available. These systems measure the velocity of blood particles

  5. Journal Article: Average Method Blank Quantities of Dioxin-Like Congeners and Their Relationship to the Detection Limits of the U.S. EPA's National Dioxin Air Monitoring Network (Ndamn)

    EPA Science Inventory

    The U.S. EPA established a National Dioxin Air Monitoring Network (NDAMN) to determine the temporal and geographical variability of atmospheric CDDs, CDFs and coplanar PCBs throughout the United States. Currently operating at 33 stations, NDAMN has, as one of its tasks, the dete...

  6. ASSESSMENT OF DYNAMIC PRA TECHNIQUES WITH INDUSTRY AVERAGE COMPONENT PERFORMANCE DATA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yadav, Vaibhav; Agarwal, Vivek; Gribok, Andrei V.

    In the nuclear industry, risk monitors are intended to provide a point-in-time estimate of the system risk given the current plant configuration. Current risk monitors are limited in that they do not properly take into account the deteriorating states of plant equipment, which are unit-specific. Current approaches to computing risk monitors use probabilistic risk assessment (PRA) techniques, but the assessment is typically a snapshot in time. Living PRA models attempt to address limitations of traditional PRA models in a limited sense by including temporary changes in plant and system configurations. However, information on plant component health are not considered. Thismore » often leaves risk monitors using living PRA models incapable of conducting evaluations with dynamic degradation scenarios evolving over time. There is a need to develop enabling approaches to solidify risk monitors to provide time and condition-dependent risk by integrating traditional PRA models with condition monitoring and prognostic techniques. This paper presents estimation of system risk evolution over time by integrating plant risk monitoring data with dynamic PRA methods incorporating aging and degradation. Several online, non-destructive approaches have been developed for diagnosing plant component conditions in nuclear industry, i.e., condition indication index, using vibration analysis, current signatures, and operational history [1]. In this work the component performance measures at U.S. commercial nuclear power plants (NPP) [2] are incorporated within the various dynamic PRA methodologies [3] to provide better estimates of probability of failures. Aging and degradation is modeled within the Level-1 PRA framework and is applied to several failure modes of pumps and can be extended to a range of components, viz. valves, generators, batteries, and pipes.« less

  7. Remote patient monitoring in chronic heart failure.

    PubMed

    Palaniswamy, Chandrasekar; Mishkin, Aaron; Aronow, Wilbert S; Kalra, Ankur; Frishman, William H

    2013-01-01

    Heart failure (HF) poses a significant economic burden on our health-care resources with very high readmission rates. Remote monitoring has a substantial potential to improve the management and outcome of patients with HF. Readmission for decompensated HF is often preceded by a stage of subclinical hemodynamic decompensation, where therapeutic interventions would prevent subsequent clinical decompensation and hospitalization. Various methods of remote patient monitoring include structured telephone support, advanced telemonitoring technologies, remote monitoring of patients with implanted cardiac devices such as pacemakers and defibrillators, and implantable hemodynamic monitors. Current data examining the efficacy of remote monitoring technologies in improving outcomes have shown inconsistent results. Various medicolegal and financial issues need to be addressed before widespread implementation of this exciting technology can take place.

  8. Digital ac monitor

    DOEpatents

    Hart, George W.; Kern, Jr., Edward C.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.

  9. Method and apparatus for measuring areas of photoelectric cells and photoelectric cell performance parameters

    DOEpatents

    Osterwald, C.R.; Emery, K.A.

    1984-05-29

    A laser scanning system for scanning the surface of photovoltaic cell in a precise, stepped raster pattern includes electric current detecting and measuring equipment for sensing the current response of the scanned cell to the laser beam at each stepped irradiated spot or pixel on the cell surface. A computer is used to control and monitor the raster position of the laser scan as well as monitoring the corresponding current responses, storing this data, operating on it, and for feeding the data to a graphical plotter for producing a visual, color-coded image of the current response of the cell to the laser scan. A translation platform driven by stepper motors in precise X and Y distances holds and rasters the cell being scanned under a stationary spot-focused laser beam.

  10. Method and apparatus for measuring areas of photoelectric cells and photoelectric cell performance parameters

    DOEpatents

    Osterwald, Carl R.; Emery, Keith A.

    1987-01-01

    A laser scanning system for scanning the surface of a photovoltaic cell in a precise, stepped raster pattern includes electric current detecting and measuring equipment for sensing the current response of the scanned cell to the laser beam at each stepped irradiated spot or pixel on the cell surface. A computer is used to control and monitor the raster position of the laser scan as well as monitoring the corresponding current responses, storing this data, operating on it, and for feeding the data to a graphic plotter for producing a visual, color-coded image of the current response of the cell to the laser scan. A translation platform driven by stepper motors in precise X and Y distances holds and rasters the cell being scanned under a stationary spot-focused laser beam.

  11. Digital ac monitor

    DOEpatents

    Hart, G.W.; Kern, E.C. Jr.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

  12. Earth Occultation Monitoring with the Fermi Gamma Ray Burst Monitor

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, Colleen A.

    2014-01-01

    Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique (EOT). Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors for daily monitoring. Light curves, updated daily, are available on our website http://heastro.phys.lsu.edu/gbm. Our software is also capable of performing the Earth occultation monitoring using up to 128 energy bands, or any combination of those bands, using our 128-channel, 4-s CSPEC data. The GBM BGO detectors, sensitive from about 200 keV to 40 keV, can also be used with this technique. In our standard application of the EOT, we use a catalog of sources to drive the measurements. To ensure that our catalog is complete, our team has developed an Earth occultation imaging method. In this talk, I will describe both techniques and the current data products available. I will highlight recent and important results from the GBM EOT, including the current status of our observations of hard X-ray variations in the Crab Nebula.

  13. Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring.

    PubMed

    Chan, Rachel W; von Deuster, Constantin; Giese, Daniel; Stoeck, Christian T; Harmer, Jack; Aitken, Andrew P; Atkinson, David; Kozerke, Sebastian

    2014-07-01

    Diffusion tensor imaging (DTI) of moving organs is gaining increasing attention but robust performance requires sequence modifications and dedicated correction methods to account for system imperfections. In this study, eddy currents in the "unipolar" Stejskal-Tanner and the velocity-compensated "bipolar" spin-echo diffusion sequences were investigated and corrected for using a magnetic field monitoring approach in combination with higher-order image reconstruction. From the field-camera measurements, increased levels of second-order eddy currents were quantified in the unipolar sequence relative to the bipolar diffusion sequence while zeroth and linear orders were found to be similar between both sequences. Second-order image reconstruction based on field-monitoring data resulted in reduced spatial misalignment artifacts and residual displacements of less than 0.43 mm and 0.29 mm (in the unipolar and bipolar sequences, respectively) after second-order eddy-current correction. Results demonstrate the need for second-order correction in unipolar encoding schemes but also show that bipolar sequences benefit from second-order reconstruction to correct for incomplete intrinsic cancellation of eddy-currents. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Comparison of alternatives to amplitude thresholding for onset detection of acoustic emission signals

    NASA Astrophysics Data System (ADS)

    Bai, F.; Gagar, D.; Foote, P.; Zhao, Y.

    2017-02-01

    Acoustic Emission (AE) monitoring can be used to detect the presence of damage as well as determine its location in Structural Health Monitoring (SHM) applications. Information on the time difference of the signal generated by the damage event arriving at different sensors in an array is essential in performing localisation. Currently, this is determined using a fixed threshold which is particularly prone to errors when not set to optimal values. This paper presents three new methods for determining the onset of AE signals without the need for a predetermined threshold. The performance of the techniques is evaluated using AE signals generated during fatigue crack growth and compared to the established Akaike Information Criterion (AIC) and fixed threshold methods. It was found that the 1D location accuracy of the new methods was within the range of < 1 - 7.1 % of the monitored region compared to 2.7% for the AIC method and a range of 1.8-9.4% for the conventional Fixed Threshold method at different threshold levels.

  15. A multitrophic approach to monitoring the effects of metal mining in otherwise pristine and ecologically sensitive rivers in northern Canada.

    PubMed

    Spencer, Paula; Bowman, Michelle F; Dubé, Monique G

    2008-07-01

    It is not known if current chemical and biological monitoring methods are appropriate for assessing the impacts of growing industrial development on ecologically sensitive northern waters. We used a multitrophic level approach to evaluate current monitoring methods and to determine whether metal-mining activities had affected 2 otherwise pristine rivers that flow into the South Nahanni River, Northwest Territories, a World Heritage Site. We compared upstream reference conditions in the rivers to sites downstream and further downstream of mines. The endpoints we evaluated included concentrations of metals in river water, sediments, and liver and flesh of slimy sculpin (Cottus cognatus); benthic algal and macroinvertebrate abundance, richness, diversity, and community composition; and various slimy sculpin measures, our sentinel forage fish species. Elevated concentrations of copper and iron in liver tissue of sculpin from the Flat River were associated with high concentrations of mine-derived iron in river water and copper in sediments that were above national guidelines. In addition, sites downstream of the mine on the Flat River had increased algal abundances and altered benthic macroinvertebrate communities, whereas the sites downstream of the mine on Prairie Creek had increased benthic macroinvertebrate taxa richness and improved sculpin condition. Biological differences in both rivers were consistent with mild enrichment of the rivers downstream of current and historical mining activity. We recommend that monitoring in these northern rivers focus on indicators in epilithon and benthic macroinvertebrate communities due to their responsiveness and as alternatives to lethal fish sampling in habitats with low fish abundance. We also recommend monitoring of metal burdens in periphyton and benthic invertebrates for assessment of exposure to mine effluent and causal association. Although the effects of mining activities on riverine biota currently are limited, our results show that there is potential for effects to occur with proposed growth in mining activities.

  16. The workshop on signatures of medical and industrial isotope production - WOSMIP; Strassoldo, Italy, 1-3 July 2009.

    PubMed

    Matthews, K M; Bowyer, T W; Saey, P R J; Payne, R F

    2012-08-01

    Radiopharmaceuticals make contributions of inestimable value to medical practice. With growing demand new technologies are being developed and applied worldwide. Most diagnostic procedures rely on (99m)Tc and the use of uranium targets in reactors is currently the favored method of production, with 95% of the necessary (99)Mo parent currently being produced by four major global suppliers. Coincidentally there are growing concerns for nuclear security and proliferation. New disarmament treaties such as the Comprehensive Nuclear-Test-Ban Treaty (CTBT) are coming into effect and treaty compliance-verification monitoring is gaining momentum. Radioxenon emissions (isotopes Xe-131, 133, 133m and 135) from radiopharmaceutical production facilities are of concern in this context because radioxenon is a highly sensitive tracer for detecting nuclear explosions. There exists, therefore, a potential for confusing source attribution, with emissions from radiopharmaceutical-production facilities regularly being detected in treaty compliance-verification networks. The CTBT radioxenon network currently under installation is highly sensitive with detection limits approaching 0.1 mBq/m³ and, depending on transport conditions and background, able to detect industrial release signatures from sites thousands of kilometers away. The method currently employed to distinguish between industrial and military radioxenon sources involves plots of isotope ratios (133m)Xe/(131m)Xe versus (135)Xe/(133)Xe, but source attribution can be ambiguous. Through the WOSMIP Workshop the environmental monitoring community is gaining a better understanding of the complexities of the processes at production facilities, and the production community is recognizing the impact their operations have on monitoring systems and their goal of nuclear non-proliferation. Further collaboration and discussion are needed, together with advances in Xe trapping technology and monitoring systems. Such initiatives will help in addressing the dichotomy which exists between expanding production and improving monitoring sensitivity, with the ultimate aim of enabling unambiguous distinction between different nuclide signatures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Use of shear waves for diagnosis and ablation monitoring of prostate cancer: a feasibility study

    NASA Astrophysics Data System (ADS)

    Gomez, A.; Rus, G.; Saffari, N.

    2016-01-01

    Prostate cancer remains as a major healthcare issue. Limitations in current diagnosis and treatment monitoring techniques imply that there is still a need for improvements. The efficacy of prostate cancer diagnosis is still low, generating under and over diagnoses. High intensity focused ultrasound ablation is an emerging treatment modality, which enables the noninvasive ablation of pathogenic tissue. Clinical trials are being carried out to evaluate its longterm efficacy as a focal treatment for prostate cancer. Successful treatment of prostate cancer using non-invasive modalities is critically dependent on accurate diagnostic means and is greatly benefited by a real-time monitoring system. While magnetic resonance imaging remains the gold standard for prostate imaging, its wider implementation for prostate cancer diagnosis remains prohibitively expensive. Conventional ultrasound is currently limited to guiding biopsy. Elastography techniques are emerging as a promising real-time imaging method, as cancer nodules are usually stiffer than adjacent healthy prostatic tissue. In this paper, a new transurethral approach is proposed, using shear waves for diagnosis and ablation monitoring of prostate cancer. A finite-difference time domain model is developed for studying the feasibility of the method, and an inverse problem technique based on genetic algorithms is proposed for reconstructing the location, size and stiffness parameters of the tumour. Preliminary results indicate that the use of shear waves for diagnosis and monitoring ablation of prostate cancer is feasible.

  18. Monitoring of formaldehyde in air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balmat, J.L.; Meadows, G.W.

    1985-10-01

    Any one of several monitoring methods, depending on requirement and circumstance, can be used to measure employee exposure to formaldehyde. Ordinarily, monitoring at DuPont is performed by sampling with impingers containing 1% aqueous sodium bisulfite or with silica gel tubes. The collected formaldehyde is measured spectrophotometrically after reaction with chromotropic acid. Results from studies on a selected number of formaldehyde monitoring methods reveal that reliable methods are available for area and personnel monitoring over both short term and long term. Accurate results are obtained from short-term monitoring (15 min at 1 L/min) with impingers of formaldehyde concentrations as low asmore » 0.14 ppm. The current studies show that long-term monitoring (8 hr at 0.5 L/min) can be performed accurately at concentrations as low as 0.05 ppm. Accurate results also are obtained from short-term monitoring (15 min at 500 mL/min) with silica gel tubes of concentrations as low as 0.11 ppm formaldehyde. Passive monitors provide the most convenient means of obtaining 8-hour time-weighted average (TWA) data. The Pro-Tek Formaldehyde Badge was demonstrated to reliably monitor formaldehyde concentrations varying from 0-0.5 ppm or 0-3 ppm. Investigation of the Lion Formaldemeter disclosed that instantaneous and accurate (+/- 5%) measurement of formaldehyde in air can be made over a concentration range of 0.3-5 ppm in the absence of other substances that are oxidizable in its fuel cell detector.« less

  19. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    NASA Astrophysics Data System (ADS)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  20. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com; Dahikar, P. B., E-mail: pbdahikar@rediffmail.com

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of bloodmore » sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.« less

  1. Vital signs monitoring on general wards: clinical staff perceptions of current practices and the planned introduction of continuous monitoring technology.

    PubMed

    Prgomet, Mirela; Cardona-Morrell, Magnolia; Nicholson, Margaret; Lake, Rebecca; Long, Janet; Westbrook, Johanna; Braithwaite, Jeffrey; Hillman, Ken

    2016-09-01

    Early detection of patient deterioration and prevention of adverse events are key challenges to patient safety. This study investigated clinical staff perceptions of current monitoring practices and the planned introduction of continuous monitoring devices on general wards. Multi-method study comprising structured surveys, in-depth interviews and device trial with log book feedback. Two general wards in a large urban teaching hospital in Sydney, Australia. Respiratory and neurosurgery nursing staff and two doctors. Nurses were confident about their abilities to identify patients at risk of deterioration, using a combination of vital signs and visual assessment. There were concerns about the accuracy of current vital signs monitoring equipment and frequency of intermittent observation. Both the nurses and the doctors were enthusiastic about the prospect of continuous monitoring and perceived it would allow earlier identification of patient deterioration; provide reassurance to patients; and support interdisciplinary communication. There were also reservations about continuous monitoring, including potential decrease in bedside nurse-patient interactions; increase in inappropriate escalations of patient care; and discomfort to patients. While continuous monitoring devices were seen as a potentially positive tool to support the identification of patient deterioration, drawbacks, such as the potential for reduced patient contact, revealed key areas that will require close surveillance following the implementation of devices. Training and improved interdisciplinary communication were identified as key requisites for successful implementation. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Project TwEATs: a feasibility study testing the use of automated text messaging to monitor appetite ratings in a free-living population

    PubMed Central

    Schembre, Susan M.; Yuen, Jessica

    2011-01-01

    There are no standardized methods for monitoring appetite in free-living populations. Fifteen participants tested a computer-automated text-messaging system designed to track hunger ratings over seven days. Participants were sent text-messages (SMS) hourly and instructed to reply during waking hours with their current hunger rating. Of 168 SMS, 0.6-7.1% were undelivered, varying by mobile service provider, On average 12 SMS responses were received daily with minor variations by observation day or day of the week. Compliance was over 74% and 93% of the ratings were received within 30-minutes. Automated text-messaging is a feasible method to monitor appetite ratings in this population. PMID:21251941

  3. Digital High-Current Monitor

    NASA Technical Reports Server (NTRS)

    Cash, B.

    1985-01-01

    Simple technique developed for monitoring direct currents up to several hundred amperes and digitally displaying values directly in current units. Used to monitor current magnitudes beyond range of standard laboratory ammeters, which typically measure 10 to 20 amperes maximum. Technique applicable to any current-monitoring situation.

  4. Process monitoring using automatic physical measurement based on electrical and physical variability analysis

    NASA Astrophysics Data System (ADS)

    Shauly, Eitan N.; Levi, Shimon; Schwarzband, Ishai; Adan, Ofer; Latinsky, Sergey

    2015-04-01

    A fully automated silicon-based methodology for systematic analysis of electrical features is shown. The system was developed for process monitoring and electrical variability reduction. A mapping step was created by dedicated structures such as static-random-access-memory (SRAM) array or standard cell library, or by using a simple design rule checking run-set. The resulting database was then used as an input for choosing locations for critical dimension scanning electron microscope images and for specific layout parameter extraction then was input to SPICE compact modeling simulation. Based on the experimental data, we identified two items that must be checked and monitored using the method described here: transistor's sensitivity to the distance between the poly end cap and edge of active area (AA) due to AA rounding, and SRAM leakage due to a too close N-well to P-well. Based on this example, for process monitoring and variability analyses, we extensively used this method to analyze transistor gates having different shapes. In addition, analysis for a large area of high density standard cell library was done. Another set of monitoring focused on a high density SRAM array is also presented. These examples provided information on the poly and AA layers, using transistor parameters such as leakage current and drive current. We successfully define "robust" and "less-robust" transistor configurations included in the library and identified unsymmetrical transistors in the SRAM bit-cells. These data were compared to data extracted from the same devices at the end of the line. Another set of analyses was done to samples after Cu M1 etch. Process monitoring information on M1 enclosed contact was extracted based on contact resistance as a feedback. Guidelines for the optimal M1 space for different layout configurations were also extracted. All these data showed the successful in-field implementation of our methodology as a useful process monitoring method.

  5. Control and monitoring method and system for electromagnetic forming process

    DOEpatents

    Kunerth, Dennis C.; Lassahn, Gordon D.

    1990-01-01

    A process, system, and improvement for a process for electromagnetic forming of a workpiece in which characteristics of the workpiece such as its geometry, electrical conductivity, quality, and magnetic permeability can be determined by monitoring the current and voltage in the workcoil. In an electromagnet forming process in which a power supply provides current to a workcoil and the electromagnetic field produced by the workcoil acts to form the workpiece, the dynamic interaction of the electromagnetic fields produced by the workcoil with the geometry, electrical conductivity, and magnetic permeability of the workpiece, provides information pertinent to the physical condition of the workpiece that is available for determination of quality and process control. This information can be obtained by deriving in real time the first several time derivatives of the current and voltage in the workcoil. In addition, the process can be extended by injecting test signals into the workcoil during the electromagnetic forming and monitoring the response to the test signals in the workcoil.

  6. Method and apparatus for measuring low currents in capacitance devices

    DOEpatents

    Kopp, M.K.; Manning, F.W.; Guerrant, G.C.

    1986-06-04

    A method and apparatus for measuring subnanoampere currents in capacitance devices is reported. The method is based on a comparison of the voltages developed across the capacitance device with that of a reference capacitor in which the current is adjusted by means of a variable current source to produce a stable voltage difference. The current varying means of the variable current source is calibrated to provide a read out of the measured current. Current gain may be provided by using a reference capacitor which is larger than the device capacitance with a corresponding increase in current supplied through the reference capacitor. The gain is then the ratio of the reference capacitance to the device capacitance. In one illustrated embodiment, the invention makes possible a new type of ionizing radiation dose-rate monitor where dose-rate is measured by discharging a reference capacitor with a variable current source at the same rate that radiation is discharging an ionization chamber. The invention eliminates high-megohm resistors and low current ammeters used in low-current measuring instruments.

  7. Error, Power, and Blind Sentinels: The Statistics of Seagrass Monitoring

    PubMed Central

    Schultz, Stewart T.; Kruschel, Claudia; Bakran-Petricioli, Tatjana; Petricioli, Donat

    2015-01-01

    We derive statistical properties of standard methods for monitoring of habitat cover worldwide, and criticize them in the context of mandated seagrass monitoring programs, as exemplified by Posidonia oceanica in the Mediterranean Sea. We report the novel result that cartographic methods with non-trivial classification errors are generally incapable of reliably detecting habitat cover losses less than about 30 to 50%, and the field labor required to increase their precision can be orders of magnitude higher than that required to estimate habitat loss directly in a field campaign. We derive a universal utility threshold of classification error in habitat maps that represents the minimum habitat map accuracy above which direct methods are superior. Widespread government reliance on blind-sentinel methods for monitoring seafloor can obscure the gradual and currently ongoing losses of benthic resources until the time has long passed for meaningful management intervention. We find two classes of methods with very high statistical power for detecting small habitat cover losses: 1) fixed-plot direct methods, which are over 100 times as efficient as direct random-plot methods in a variable habitat mosaic; and 2) remote methods with very low classification error such as geospatial underwater videography, which is an emerging, low-cost, non-destructive method for documenting small changes at millimeter visual resolution. General adoption of these methods and their further development will require a fundamental cultural change in conservation and management bodies towards the recognition and promotion of requirements of minimal statistical power and precision in the development of international goals for monitoring these valuable resources and the ecological services they provide. PMID:26367863

  8. SHARP: A multi-mission artificial intelligence system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager 2 spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  9. Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects.

    PubMed

    Brown, Matthew S; Ashley, Brandon; Koh, Ahyeon

    2018-01-01

    Chronic non-healing wounds challenge tissue regeneration and impair infection regulation for patients afflicted with this condition. Next generation wound care technology capable of in situ physiological surveillance which can diagnose wound parameters, treat various chronic wound symptoms, and reduce infection at the wound noninvasively with the use of a closed loop therapeutic system would provide patients with an improved standard of care and an accelerated wound repair mechanism. The indicating biomarkers specific to chronic wounds include blood pressure, temperature, oxygen, pH, lactate, glucose, interleukin-6 (IL-6), and infection status. A wound monitoring device would help decrease prolonged hospitalization, multiple doctors' visits, and the expensive lab testing associated with the diagnosis and treatment of chronic wounds. A device capable of monitoring the wound status and stimulating the healing process is highly desirable. In this review, we discuss the impaired physiological states of chronic wounds and explain the current treatment methods. Specifically, we focus on improvements in materials, platforms, fabrication methods for wearable devices, and quantitative analysis of various biomarkers vital to wound healing progress.

  10. Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects

    PubMed Central

    Brown, Matthew S.; Ashley, Brandon; Koh, Ahyeon

    2018-01-01

    Chronic non-healing wounds challenge tissue regeneration and impair infection regulation for patients afflicted with this condition. Next generation wound care technology capable of in situ physiological surveillance which can diagnose wound parameters, treat various chronic wound symptoms, and reduce infection at the wound noninvasively with the use of a closed loop therapeutic system would provide patients with an improved standard of care and an accelerated wound repair mechanism. The indicating biomarkers specific to chronic wounds include blood pressure, temperature, oxygen, pH, lactate, glucose, interleukin-6 (IL-6), and infection status. A wound monitoring device would help decrease prolonged hospitalization, multiple doctors' visits, and the expensive lab testing associated with the diagnosis and treatment of chronic wounds. A device capable of monitoring the wound status and stimulating the healing process is highly desirable. In this review, we discuss the impaired physiological states of chronic wounds and explain the current treatment methods. Specifically, we focus on improvements in materials, platforms, fabrication methods for wearable devices, and quantitative analysis of various biomarkers vital to wound healing progress. PMID:29755977

  11. Methodology of Dynamic Monitoring of Structures in the Vicinity of Hydrotechnical Works - Selected Case Studies

    NASA Astrophysics Data System (ADS)

    Wyjadłowski, Marek

    2017-12-01

    The constant development of geotechnical technologies imposes the necessity of monitoring techniques to provide a proper quality and the safe execution of geotechnical works. Several monitoring methods enable the preliminary design of work process and current control of hydrotechnical works (pile driving, sheet piling, ground improvement methods). Wave parameter measurements and/or continuous histogram recording of shocks and vibrations and its dynamic impact on engineering structures in the close vicinity of the building site enable the modification of the technology parameters, such as vibrator frequency or hammer drop height. Many examples of practical applications have already been published and provide a basis for the formulation of guidelines, for work on the following sites. In the current work the author's experience gained during sheet piling works for the reconstruction of City Channel in Wrocław (Poland) was presented. The examples chosen describe ways of proceedings in the case of new and old residential buildings where the concrete or masonry walls were exposed to vibrations and in the case of the hydrotechnical structures (sluices, bridges).

  12. SHARP: A multi-mission AI system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager II spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real-time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real-time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  13. Estimates of Dietary Sodium Consumption in Patients With Chronic Heart Failure.

    PubMed

    Colin-Ramirez, Eloisa; Arcand, JoAnne; Ezekowitz, Justin A

    2015-12-01

    Estimating dietary sodium intake is a key component of dietary assessment in the clinical setting of HF to effectively implement appropriate dietary interventions for sodium reduction and monitor adherence to the dietary treatment. In a research setting, assessment of sodium intake is crucial to an essential methodology to evaluate outcomes after a dietary or behavioral intervention. Current available sodium intake assessment methods include 24-hour urine collection, spot urine collections, multiple day food records, food recalls, and food frequency questionnaires. However, these methods have inherent limitations that make assessment of sodium intake challenging, and the utility of traditional methods may be questionable for estimating sodium intake in patients with HF. Thus, there are remaining questions about how to best assess dietary sodium intake in this patient population, and there is a need to identify a reliable method to assess and monitor sodium intake in the research and clinical setting of HF. This paper provides a comprehensive review of the current methods for sodium intake assessment, addresses the challenges for its accurate evaluation, and highlights the relevance of applying the highest-quality measurement methods in the research setting to minimize the risk of biased data. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. A Review of Player Monitoring Approaches in Basketball: Current Trends and Future Directions.

    PubMed

    Fox, Jordan L; Scanlan, Aaron T; Stanton, Robert

    2017-07-01

    Fox, JL, Scanlan, AT, and Stanton, R. A review of player monitoring approaches in basketball: current trends and future directions. J Strength Cond Res 31(7): 2021-2029, 2017-Effective monitoring of players in team sports such as basketball requires an understanding of the external demands and internal responses, as they relate to training phases and competition. Monitoring of external demands and internal responses allows coaching staff to determine the dose-response associated with the imposed training load (TL), and subsequently, if players are adequately prepared for competition. This review discusses measures reported in the literature for monitoring the external demands and internal responses of basketball players during training and competition. The external demands of training and competition were primarily monitored using time-motion analysis, with limited use of microtechnology being reported. Internal responses during training were typically measured using hematological markers, heart rate, various TL models, and perceptual responses such as rating of perceived exertion (RPE). Heart rate was the most commonly reported indicator of internal responses during competition with limited reporting of hematological markers or RPE. These findings show a large discrepancy between the reporting of external and internal measures and training and competition demands. Microsensors, however, may be a practical and convenient method of player monitoring in basketball to overcome the limitations associated with current approaches while allowing for external demands and internal responses to be recorded simultaneously. The triaxial accelerometers of microsensors seem well suited for basketball and warrant validation to definitively determine their place in the monitoring of basketball players. Coaching staff should make use of this technology by tracking individual player responses across the annual plan and using real-time monitoring to minimize factors such as fatigue and injury risk.

  15. Analytical chemistry in water quality monitoring during manned space missions

    NASA Astrophysics Data System (ADS)

    Artemyeva, Anastasia A.

    2016-09-01

    Water quality monitoring during human spaceflights is essential. However, most of the traditional methods require sample collection with a subsequent ground analysis because of the limitations in volume, power, safety and gravity. The space missions are becoming longer-lasting; hence methods suitable for in-flight monitoring are demanded. Since 2009, water quality has been monitored in-flight with colorimetric methods allowing for detection of iodine and ionic silver. Organic compounds in water have been monitored with a second generation total organic carbon analyzer, which provides information on the amount of carbon in water at both the U.S. and Russian segments of the International Space Station since 2008. The disadvantage of this approach is the lack of compound-specific information. The recently developed methods and tools may potentially allow one to obtain in-flight a more detailed information on water quality. Namely, the microanalyzers based on potentiometric measurements were designed for online detection of chloride, potassium, nitrate ions and ammonia. The recent application of the current highly developed air quality monitoring system for water analysis was a logical step because most of the target analytes are the same in air and water. An electro-thermal vaporizer was designed, manufactured and coupled with the air quality control system. This development allowed for liberating the analytes from the aqueous matrix and further compound-specific analysis in the gas phase.

  16. Quantitative monitoring of lipid accumulation over time in cultured adipocytes as function of culture conditions: toward controlled adipose tissue engineering.

    PubMed

    Or-Tzadikario, Shira; Sopher, Ran; Gefen, Amit

    2010-10-01

    Adipose tissue engineering is investigated for native fat substitutes and wound healing model systems. Research and clinical applications of bioartificial fat require a quantitative and objective method to continuously measure adipogenesis in living cultures as opposed to currently used culture-destructive techniques that stain lipid droplet (LD) accumulation. To allow standardization, automatic quantification of LD size is further needed, but currently LD size is measured mostly manually. We developed an image processing-based method that does not require staining to monitor adipose cell maturation in vitro nondestructively using optical micrographs taken consecutively during culturing. We employed our method to monitor LD accumulation in 3T3-L1 and mesenchymal stem cells over 37 days. For each cell type, percentage of lipid area, number of droplets per cell, and droplet diameter were obtained every 2-3 days. In 3T3-L1 cultures, high insulin concentration (10 microg/mL) yielded a significantly different (p < 0.01) time course of all three outcome measures. In mesenchymal stem cell cultures, high fetal bovine serum concentration (12.5%) produced significantly more lipid area (p < 0.01). Our method was able to successfully characterize time courses and extents of adipogenesis and is useful for a wide range of applications testing the effects of biochemical, mechanical, and thermal stimulations in tissue engineering of bioartificial fat constructs.

  17. Compliance and patching and atropine amblyopia treatments.

    PubMed

    Wang, Jingyun

    2015-09-01

    In the past 20 years, there has been a great advancement in knowledge pertaining to compliance with amblyopia treatments. The occlusion dose monitor introduced quantitative monitoring methods in patching, which sparked our initial understanding of the dose-response relationship for patching amblyopia treatment. This review focuses on current compliance knowledge and the impact it has on patching and atropine amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. PRISM: A DATA-DRIVEN PLATFORM FOR MONITORING MENTAL HEALTH

    PubMed Central

    KAMDAR, MAULIK R.; WU, MICHELLE J.

    2018-01-01

    Neuropsychiatric disorders are the leading cause of disability worldwide and there is no gold standard currently available for the measurement of mental health. This issue is exacerbated by the fact that the information physicians use to diagnose these disorders is episodic and often subjective. Current methods to monitor mental health involve the use of subjective DSM-5 guidelines, and advances in EEG and video monitoring technologies have not been widely adopted due to invasiveness and inconvenience. Wearable technologies have surfaced as a ubiquitous and unobtrusive method for providing continuous, quantitative data about a patient. Here, we introduce PRISM — Passive, Real-time Information for Sensing Mental Health. This platform integrates motion, light and heart rate data from a smart watch application with user interactions and text insights from a web application. We have demonstrated a proof of concept by collecting preliminary data through a pilot study of 13 subjects. We have engineered appropriate features and applied both unsupervised and supervised learning to develop models that can recapitulate user-reported ratings of their emotional state. This demonstrates that the data has the potential to be useful for evaluating mental health. This platform will allow us to leverage continuous streams of passive data for early and accurate diagnosis as well as constant monitoring of patients suffering from mental disorders. PMID:26776198

  19. Building capacity in biodiversity monitoring at the global scale

    USGS Publications Warehouse

    Schmeller, Dirk S.; Bohm, Monika; Arvanitidis, Christos; Barber-Meyer, Shannon; Brummitt, Neil; Chandler, Mark; Chatzinikolaou, Eva; Costello, Mark J.; Ding, Hui; García-Moreno, Jaime; Gill, Michael J.; Haase, Peter; Jones, Miranda; Juillard, Romain; Magnusson, William E.; Martin, Corinne S.; McGeoch, Melodie A.; Mihoub, Jean-Baptiste; Pettorelli, Nathalie; Proença, Vânia; Peng, Cui; Regan, Eugenie; Schmiedel, Ute; Simsika, John P.; Weatherdon, Lauren; Waterman, Carly; Xu, Haigen; Belnap, Jayne

    2017-01-01

    Human-driven global change is causing ongoing declines in biodiversity worldwide. In order to address these declines, decision-makers need accurate assessments of the status of and pressures on biodiversity. However, these are heavily constrained by incomplete and uneven spatial, temporal and taxonomic coverage. For instance, data from regions such as Europe and North America are currently used overwhelmingly for large-scale biodiversity assessments due to lesser availability of suitable data from other, more biodiversity-rich, regions. These data-poor regions are often those experiencing the strongest threats to biodiversity, however. There is therefore an urgent need to fill the existing gaps in global biodiversity monitoring. Here, we review current knowledge on best practice in capacity building for biodiversity monitoring and provide an overview of existing means to improve biodiversity data collection considering the different types of biodiversity monitoring data. Our review comprises insights from work in Africa, South America, Polar Regions and Europe; in government-funded, volunteer and citizen-based monitoring in terrestrial, freshwater and marine ecosystems. The key steps to effectively building capacity in biodiversity monitoring are: identifying monitoring questions and aims; identifying the key components, functions, and processes to monitor; identifying the most suitable monitoring methods for these elements, carrying out monitoring activities; managing the resultant data; and interpreting monitoring data. Additionally, biodiversity monitoring should use multiple approaches including extensive and intensive monitoring through volunteers and professional scientists but also harnessing new technologies. Finally, we call on the scientific community to share biodiversity monitoring data, knowledge and tools to ensure the accessibility, interoperability, and reporting of biodiversity data at a global scale.

  20. The U.S. Department of Agriculture Automated Multiple-Pass Method accurately assesses sodium intakes

    USDA-ARS?s Scientific Manuscript database

    Accurate and practical methods to monitor sodium intake of the U.S. population are critical given current sodium reduction strategies. While the gold standard for estimating sodium intake is the 24 hour urine collection, few studies have used this biomarker to evaluate the accuracy of a dietary ins...

  1. Possible strategies for EDC testing in the future: exploring roles of pathway-based in silico, in vitro and in vivo methods

    EPA Science Inventory

    Current methods for screening, testing and monitoring endocrine-disrupting chemicals (EDCs) rely relatively substantially upon moderate- to long-term assays that can, in some instances, require significant numbers of animals. Recent developments in the areas of in vitro testing...

  2. Refinery evaluation of optical imaging to locate fugitive emissions.

    PubMed

    Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike

    2007-07-01

    Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.

  3. A method for estimating cost savings for population health management programs.

    PubMed

    Murphy, Shannon M E; McGready, John; Griswold, Michael E; Sylvia, Martha L

    2013-04-01

    To develop a quasi-experimental method for estimating Population Health Management (PHM) program savings that mitigates common sources of confounding, supports regular updates for continued program monitoring, and estimates model precision. Administrative, program, and claims records from January 2005 through June 2009. Data are aggregated by member and month. Study participants include chronically ill adult commercial health plan members. The intervention group consists of members currently enrolled in PHM, stratified by intensity level. Comparison groups include (1) members never enrolled, and (2) PHM participants not currently enrolled. Mixed model smoothing is employed to regress monthly medical costs on time (in months), a history of PHM enrollment, and monthly program enrollment by intensity level. Comparison group trends are used to estimate expected costs for intervention members. Savings are realized when PHM participants' costs are lower than expected. This method mitigates many of the limitations faced using traditional pre-post models for estimating PHM savings in an observational setting, supports replication for ongoing monitoring, and performs basic statistical inference. This method provides payers with a confident basis for making investment decisions. © Health Research and Educational Trust.

  4. Analytical Pitfalls of Therapeutic Drug Monitoring of Thiopurines in Patients With Inflammatory Bowel Disease

    PubMed Central

    Meijer, Berrie; Mulder, Chris J. J.; van Bodegraven, Adriaan A.; de Boer, Nanne K. H.

    2017-01-01

    Abstract: The use of thiopurines in the treatment of inflammatory bowel disease (IBD) can be optimized by the application of therapeutic drug monitoring. In this procedure, 6-thioguanine nucleotides (6-TGN) and 6-methylmercaptopurine (6-MMP) metabolites are monitored and related to therapeutic response and adverse events, respectively. Therapeutic drug monitoring of thiopurines, however, is hampered by several analytical limitations resulting in an impaired translation of metabolite levels to clinical outcome in IBD. Thiopurine metabolism is cell specific and requires nucleated cells and particular enzymes for 6-TGN formation. In the current therapeutic drug monitoring, metabolite levels are assessed in erythrocytes, whereas leukocytes are considered the main target cells of these drugs. Furthermore, currently used methods do not distinguish between active nucleotides and their unwanted residual products. Last, there is a lack of a standardized laboratorial procedure for metabolite assessment regarding the substantial instability of erythrocyte 6-TGN. To improve thiopurine therapy in patients with IBD, it is necessary to understand these limitations and recognize the general misconceptions in this procedure. PMID:29040228

  5. Aquatic organism passage at road-stream crossings—synthesis and guidelines for effectiveness monitoring

    USGS Publications Warehouse

    Hoffman, Robert L.; Dunham, Jason B.; Hansen, Bruce P.

    2012-01-01

    Restoration and maintenance of passage for aquatic organisms at road-stream crossings represents a major management priority, involving an investment of hundreds of millions of dollars (for example, U.S. Government Accounting Office, 2001). In recent years, passage at hundreds of crossings has been restored, primarily by replacing barrier road culverts with bridges or stream simulation culverts designed to pass all species and all life stages of aquatic life and simulate natural hydro-geomorphic processes (U.S. Forest Service, 2008). The current situation has motivated two general questions: 1. Are current design standards for stream simulation culverts adequately re-establishing passage for aquatic biota? and 2. How do we monitor and evaluate effectiveness of passage restoration? To address the latter question, a national workshop was held in March 2010, in Portland, Oregon. The workshop included experts on aquatic organism passage from across the nation (see table of participants, APPENDIX) who addressed four classes of methods for monitoring effectiveness of aquatic organism passage—individual movement, occupancy, demography, and genetics. This report has been written, in part, for field biologists who will be undertaking and evaluating the effectiveness of aquatic organism passage restoration projects at road-stream crossings. The report outlines basic methods for evaluating road-stream crossing passage impairment and restoration and discusses under what circumstances and conditions each method will be useful; what questions each method can potentially answer; how to design and implement an evaluation study; and points out the fundamental reality that most evaluation projects will require special funding and partnerships among researchers and resource managers. The report is organized into the following sections, which can be read independently: 1. Historical context: In this section, we provide a brief history of events leading up to the present situation involving aquatic organism passage as a useful context for the issues covered herein. 2. Importance of connectivity for aquatic organisms: In this section, we provide background information regarding the movement characteristics of aquatic organisms and their vulnerability to passage impairment, and the importance of connectivity for a broad diversity of aquatic vertebrates and invertebrates. This section should be useful for practitioners in selecting what species to monitor in relation to aquatic organism passage. 3. Methods for evaluating aquatic organism passage: In this section, we present a range of perspectives on alternatives for assessing and monitoring aquatic organism passage impairment and the effectiveness of passage restoration actions, including the following methods: Individual Movement, Occupancy Models, Abundance (Demography), and Molecular Genetic Markers. 4. Relevance, strengths, and limitations of the four methods: In this section, we discuss the utility of each of the methods as a tool for assessing and quantifying passage impairment and restoration effectiveness. 5. Guidelines for selecting a method: In this section, we review some fundamental criteria and guidelines to consider when selecting a method for monitoring in the context of answering three important questions that should be addressed when developing a plan for evaluating aquatic organism passage. 6. Study and monitoring design considerations: In this section, we discuss four key design elements that need to be considered when developing a monitoring design for assessing passage impairment and restoration. The basic objectives of the report are to: 1. Review the movement characteristics of five groups of aquatic organisms that inhabit streams and to assess their general vulnerability to passage impairment at road-stream crossings; 2. Review four methods for monitoring aquatic organism passage impairment and the effectiveness of actions to restore passage at road-stream crossing structures; 3. Assess the relevance, strengths, and limitations of each method as a monitoring tool; 4. Identify and discuss guidelines that will be useful for selecting a monitoring method; and 5. Discuss what we have identified as the four key elements that need to be considered when developing a monitoring design for assessing passage impairment and restoration at road-stream crossings.

  6. Recent advances in immunosensor for narcotic drug detection

    PubMed Central

    Gandhi, Sonu; Suman, Pankaj; Kumar, Ashok; Sharma, Prince; Capalash, Neena; Suri, C. Raman

    2015-01-01

    Introduction: Immunosensor for illicit drugs have gained immense interest and have found several applications for drug abuse monitoring. This technology has offered a low cost detection of narcotics; thereby, providing a confirmatory platform to compliment the existing analytical methods. Methods: In this minireview, we define the basic concept of transducer for immunosensor development that utilizes antibodies and low molecular mass hapten (opiate) molecules. Results: This article emphasizes on recent advances in immunoanalytical techniques for monitoring of opiate drugs. Our results demonstrate that high quality antibodies can be used for immunosensor development against target analyte with greater sensitivity, specificity and precision than other available analytical methods. Conclusion: In this review we highlight the fundamentals of different transducer technologies and its applications for immunosensor development currently being developed in our laboratory using rapid screening via immunochromatographic kit, label free optical detection via enzyme, fluorescence, gold nanoparticles and carbon nanotubes based immunosensing for sensitive and specific monitoring of opiates. PMID:26929925

  7. Industrial chimney monitoring - contemporary methods

    NASA Astrophysics Data System (ADS)

    Kaszowska, Olga; Gruchlik, Piotr; Mika, Wiesław

    2018-04-01

    The paper presents knowledge acquired during the monitoring of a flue-gas stack, performed as part of technical and scientific surveillance of mining activity and its impact on industrial objects. The chimney is located in an area impacted by mining activity since the 1970s, from a coal mine which is no longer in existence. In the period of 2013-16, this area was subject to mining carried out by a mining entrepreneur who currently holds a license to excavate hard coal. Periodic measurements of the deflection of the 113-meter chimney are performed using conventional geodetic methods. The GIG used 3 methods to observe the stack: landbased 3D laser scanning, continuous deflection monitoring with a laser sensor, and drone-based visual inspections. The drone offered the possibility to closely inspect the upper sections of the flue-gas stack, which are difficult to see from the ground level.

  8. A subjective scheduler for subjective dedicated networks

    NASA Astrophysics Data System (ADS)

    Suherman; Fakhrizal, Said Reza; Al-Akaidi, Marwan

    2017-09-01

    Multiple access technique is one of important techniques within medium access layer in TCP/IP protocol stack. Each network technology implements the selected access method. Priority can be implemented in those methods to differentiate services. Some internet networks are dedicated for specific purpose. Education browsing or tutorial video accesses are preferred in a library hotspot, while entertainment and sport contents could be subjects of limitation. Current solution may use IP address filter or access list. This paper proposes subjective properties of users or applications are used for priority determination in multiple access techniques. The NS-2 simulator is employed to evaluate the method. A video surveillance network using WiMAX is chosen as the object. Subjective priority is implemented on WiMAX scheduler based on traffic properties. Three different traffic sources from monitoring video: palace, park, and market are evaluated. The proposed subjective scheduler prioritizes palace monitoring video that results better quality, xx dB than the later monitoring spots.

  9. WFC3/IR Blob Monitoring

    NASA Astrophysics Data System (ADS)

    Sunnquist, Ben

    2018-06-01

    Throughout the lifetime of WFC3, a growing number of 'blobs' (small, circular regions with slightly decreased sensitivity) have appeared in WFC3/IR images. In this report, we present the current workflow used for identifying, characterizing and flagging new IR blobs. We also describe the methods currently used to monitor the repeatability of the channel select mechanism (CSM) movements as a way to ensure that the CSM is still operating normally as these new blobs form. A full listing of all known blobs, which incorporates the work from past blob monitoring efforts, is presented in the Appendix as well as all of the IR bad pixel tables generated to include the strongest of these blobs. These tables, along with all of the other relevant figures and tables in this report, will be continuously updated as new blobs form.

  10. Video-based respiration monitoring with automatic region of interest detection.

    PubMed

    Janssen, Rik; Wang, Wenjin; Moço, Andreia; de Haan, Gerard

    2016-01-01

    Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that automatically detects a respiratory region of interest (RoI) and signal using a camera. Based on the observation that respiration induced chest/abdomen motion is an independent motion system in a video, our basic idea is to exploit the intrinsic properties of respiration to find the respiratory RoI and extract the respiratory signal via motion factorization. We created a benchmark dataset containing 148 video sequences obtained on adults under challenging conditions and also neonates in the neonatal intensive care unit (NICU). The measurements obtained by the proposed video respiration monitoring (VRM) method are not significantly different from the reference methods (guided breathing or contact-based ECG; p-value  =  0.6), and explain more than 99% of the variance of the reference values with low limits of agreement (-2.67 to 2.81 bpm). VRM seems to provide a valid solution to ECG in confined motion scenarios, though precision may be reduced for neonates. More studies are needed to validate VRM under challenging recording conditions, including upper-body motion types.

  11. A real time study on condition monitoring of distribution transformer using thermal imager

    NASA Astrophysics Data System (ADS)

    Mariprasath, T.; Kirubakaran, V.

    2018-05-01

    The transformer is one of the critical apparatus in the power system. At any cost, a few minutes of outages harshly influence the power system. Hence, prevention-based maintenance technique is very essential. The continuous conditioning and monitoring technology significantly increases the life span of the transformer, as well as reduces the maintenance cost. Hence, conditioning and monitoring of transformer's temperature are very essential. In this paper, a critical review has been made on various conditioning and monitoring techniques. Furthermore, a new method, hot spot indication technique, is discussed. Also, transformer's operating condition is monitored by using thermal imager. From the thermal analysis, it is inferred that major hotspot locations are appearing at connection lead out; also, the bushing of the transformer is the very hottest spot in transformer, so monitoring the level of oil is essential. Alongside, real time power quality analysis has been carried out using the power analyzer. It shows that industrial drives are injecting current harmonics to the distribution network, which causes the power quality problem on the grid. Moreover, the current harmonic limit has exceeded the IEEE standard limit. Hence, the adequate harmonics suppression technique is need an hour.

  12. Thoracic organ transplantation: laboratory methods.

    PubMed

    Patel, Jignesh K; Kobashigawa, Jon A

    2013-01-01

    Although great progress has been achieved in thoracic organ transplantation through the development of effective immunosuppression, there is still significant risk of rejection during the early post-transplant period, creating a need for routine monitoring for both acute antibody and cellular mediated rejection. The currently available multiplexed, microbead assays utilizing solubilized HLA antigens afford the capability of sensitive detection and identification of HLA and non-HLA specific antibodies. These assays are being used to assess the relative strength of donor specific antibodies; to permit performance of virtual crossmatches which can reduce the waiting time to transplantation; to monitor antibody levels during desensitization; and for heart transplants to monitor antibodies post-transplant. For cell mediated immune responses, the recent development of gene expression profiling has allowed noninvasive monitoring of heart transplant recipients yielding predictive values for acute cellular rejection. T cell immune monitoring in heart and lung transplant recipients has allowed individual tailoring of immunosuppression, particularly to minimize risk of infection. While the current antibody and cellular laboratory techniques have enhanced the ability to manage thoracic organ transplant recipients, future developments from improved understanding of microchimerism and graft tolerance may allow more refined allograft monitoring techniques.

  13. Pollen and spore monitoring in the world.

    PubMed

    Buters, J T M; Antunes, C; Galveias, A; Bergmann, K C; Thibaudon, M; Galán, C; Schmidt-Weber, C; Oteros, J

    2018-01-01

    Ambient air quality monitoring is a governmental duty that is widely carried out in order to detect non-biological ("chemical") components in ambient air, such as particles of < 10 µm (PM 10 , PM 2.5 ), ozone, sulphur dioxide, and nitrogen oxides. These monitoring networks are publicly funded and air quality data are open to the public. The situation for biological particles that have detrimental effects on health, as is the case of pollen and fungal spores, is however very different. Most pollen and spore monitoring networks are not publicly funded and data are not freely available. The information regarding which biological particle is being monitored, where and by whom, is consequently often not known, even by aerobiologists themselves. This is a considerable problem, as local pollen data are an important tool for the prevention of allergic symptoms. The aim of this study was to review pollen monitoring stations throughout the world and to create an interactive visualization of their distribution. The method employed to collect information was based on: (a) a review of the recent and historical bibliography related to pollen and fungal spore monitoring, and (b) personal surveys of the managers of national and regional monitoring networks. The interactive application was developed using the R programming language. We have created an inventory of the active pollen and spore monitoring stations in the world. There are at least 879 active pollen monitoring stations in the world, most of which are in Europe (> 500). The prevalent monitoring method is based on the Hirst principle (> 600 stations). The inventory is visualised as an interactive and on-line map. It can be searched, its appearance can be adjusted to the users' needs and it is updated regularly, as new stations or changes to those that already exist can be submitted online. The map shows the current situation of pollen and spore monitoring and facilitates collaboration among those individuals who are interested in pollen and spore counts. It might also help to improve the monitoring of biological particles up to the current level employed for non-biological components.

  14. Lung function imaging methods in Cystic Fibrosis pulmonary disease.

    PubMed

    Kołodziej, Magdalena; de Veer, Michael J; Cholewa, Marian; Egan, Gary F; Thompson, Bruce R

    2017-05-17

    Monitoring of pulmonary physiology is fundamental to the clinical management of patients with Cystic Fibrosis. The current standard clinical practise uses spirometry to assess lung function which delivers a clinically relevant functional readout of total lung function, however does not supply any visible or localised information. High Resolution Computed Tomography (HRCT) is a well-established current 'gold standard' method for monitoring lung anatomical changes in Cystic Fibrosis patients. HRCT provides excellent morphological information, however, the X-ray radiation dose can become significant if multiple scans are required to monitor chronic diseases such as cystic fibrosis. X-ray phase-contrast imaging is another emerging X-ray based methodology for Cystic Fibrosis lung assessment which provides dynamic morphological and functional information, albeit with even higher X-ray doses than HRCT. Magnetic Resonance Imaging (MRI) is a non-ionising radiation imaging method that is garnering growing interest among researchers and clinicians working with Cystic Fibrosis patients. Recent advances in MRI have opened up the possibilities to observe lung function in real time to potentially allow sensitive and accurate assessment of disease progression. The use of hyperpolarized gas or non-contrast enhanced MRI can be tailored to clinical needs. While MRI offers significant promise it still suffers from poor spatial resolution and the development of an objective scoring system especially for ventilation assessment.

  15. Controlling intake of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Eckerman, Keith F; McGinn, Wilson

    2012-01-01

    This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for settingmore » standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.« less

  16. The Real-Time Monitoring Service Platform for Land Supervision Based on Cloud Integration

    NASA Astrophysics Data System (ADS)

    Sun, J.; Mao, M.; Xiang, H.; Wang, G.; Liang, Y.

    2018-04-01

    Remote sensing monitoring has become the important means for land and resources departments to strengthen supervision. Aiming at the problems of low monitoring frequency and poor data currency in current remote sensing monitoring, this paper researched and developed the cloud-integrated real-time monitoring service platform for land supervision which enhanced the monitoring frequency by acquiring the domestic satellite image data overall and accelerated the remote sensing image data processing efficiency by exploiting the intelligent dynamic processing technology of multi-source images. Through the pilot application in Jinan Bureau of State Land Supervision, it has been proved that the real-time monitoring technical method for land supervision is feasible. In addition, the functions of real-time monitoring and early warning are carried out on illegal land use, permanent basic farmland protection and boundary breakthrough in urban development. The application has achieved remarkable results.

  17. Technological advances in perioperative monitoring: Current concepts and clinical perspectives

    PubMed Central

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any. PMID:25788767

  18. Technological advances in perioperative monitoring: Current concepts and clinical perspectives.

    PubMed

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.

  19. Statistical approaches used to assess and redesign surface water-quality-monitoring networks.

    PubMed

    Khalil, B; Ouarda, T B M J

    2009-11-01

    An up-to-date review of the statistical approaches utilized for the assessment and redesign of surface water quality monitoring (WQM) networks is presented. The main technical aspects of network design are covered in four sections, addressing monitoring objectives, water quality variables, sampling frequency and spatial distribution of sampling locations. This paper discusses various monitoring objectives and related procedures used for the assessment and redesign of long-term surface WQM networks. The appropriateness of each approach for the design, contraction or expansion of monitoring networks is also discussed. For each statistical approach, its advantages and disadvantages are examined from a network design perspective. Possible methods to overcome disadvantages and deficiencies in the statistical approaches that are currently in use are recommended.

  20. Thin wire pointing method

    NASA Technical Reports Server (NTRS)

    Green, G.; Mattauch, R. J. (Inventor)

    1983-01-01

    A method is described for forming sharp tips on thin wires, in particular phosphor bronze wires of diameters such as one-thousandth inch used to contact micron size Schottky barrier diodes, which enables close control of tip shape and which avoids the use of highly toxic solutions. The method includes dipping an end of a phosphor bronze wire into a dilute solution of sulfamic acid and applying a current through the wire to electrochemically etch it. The humidity in the room is controlled to a level of less than 50%, and the voltage applied between the wire and another electrode in the solutions is a half wave rectified voltage. The current through the wire is monitored, and the process is stopped when the current falls to a predetermined low level.

  1. Monitoring Temperature and Fan Speed Using Ganglia and Winbond Chips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Cattie; /SLAC

    2006-09-27

    Effective monitoring is essential to keep a large group of machines, like the ones at Stanford Linear Accelerator Center (SLAC), up and running. SLAC currently uses Ganglia Monitoring System to observe about 2000 machines, analyzing metrics like CPU usage and I/O rate. However, metrics essential to machine hardware health, such as temperature and fan speed, are not being monitored. Many machines have a Winbond w83782d chip which monitors three temperatures, two of which come from dual CPUs, and returns the information when the sensor command is invoked. Ganglia also provides a feature, gmetric, that allows the users to monitor theirmore » own metrics and incorporate them into the monitoring system. The programming language Perl is chosen to implement a script that invokes the sensors command, extracts the temperature and fan speed information, and calls gmetric with the appropriate arguments. Two machines were used to test the script; the two CPUs on each machine run at about 65 Celsius, which is well within the operating temperature range (The maximum safe temperature range is 77-82 Celsius for the Pentium III processors being used). Installing the script on all machines with a Winbond w83782d chip allows the SLAC Scientific Computing and Computing Services group (SCCS) to better evaluate current cooling methods.« less

  2. Antibody Epitope Analysis to Investigate Folded Structure, Allosteric Conformation, and Evolutionary Lineage of Proteins.

    PubMed

    Wong, Sienna; Jin, J-P

    2017-01-01

    Study of folded structure of proteins provides insights into their biological functions, conformational dynamics and molecular evolution. Current methods of elucidating folded structure of proteins are laborious, low-throughput, and constrained by various limitations. Arising from these methods is the need for a sensitive, quantitative, rapid and high-throughput method not only analysing the folded structure of proteins, but also to monitor dynamic changes under physiological or experimental conditions. In this focused review, we outline the foundation and limitations of current protein structure-determination methods prior to discussing the advantages of an emerging antibody epitope analysis for applications in structural, conformational and evolutionary studies of proteins. We discuss the application of this method using representative examples in monitoring allosteric conformation of regulatory proteins and the determination of the evolutionary lineage of related proteins and protein isoforms. The versatility of the method described herein is validated by the ability to modulate a variety of assay parameters to meet the needs of the user in order to monitor protein conformation. Furthermore, the assay has been used to clarify the lineage of troponin isoforms beyond what has been depicted by sequence homology alone, demonstrating the nonlinear evolutionary relationship between primary structure and tertiary structure of proteins. The antibody epitope analysis method is a highly adaptable technique of protein conformation elucidation, which can be easily applied without the need for specialized equipment or technical expertise. When applied in a systematic and strategic manner, this method has the potential to reveal novel and biomedically meaningful information for structure-function relationship and evolutionary lineage of proteins. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Final Technical Report Recovery Act: Online Nonintrusive Condition Monitoring and Fault Detection for Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei Qiao

    2012-05-29

    The penetration of wind power has increased greatly over the last decade in the United States and across the world. The U.S. wind power industry installed 1,118 MW of new capacity in the first quarter of 2011 alone and entered the second quarter with another 5,600 MW under construction. By 2030, wind energy is expected to provide 20% of the U.S. electricity needs. As the number of wind turbines continues to grow, the need for effective condition monitoring and fault detection (CMFD) systems becomes increasingly important [3]. Online CMFD is an effective means of not only improving the reliability, capacitymore » factor, and lifetime, but it also reduces the downtime, energy loss, and operation and maintenance (O&M) of wind turbines. The goal of this project is to develop novel online nonintrusive CMFD technologies for wind turbines. The proposed technologies use only the current measurements that have been used by the control and protection system of a wind turbine generator (WTG); no additional sensors or data acquisition devices are needed. Current signals are reliable and easily accessible from the ground without intruding on the wind turbine generators (WTGs) that are situated on high towers and installed in remote areas. Therefore, current-based CMFD techniques have great economic benefits and the potential to be adopted by the wind energy industry. Specifically, the following objectives and results have been achieved in this project: (1) Analyzed the effects of faults in a WTG on the generator currents of the WTG operating at variable rotating speed conditions from the perspective of amplitude and frequency modulations of the current measurements; (2) Developed effective amplitude and frequency demodulation methods for appropriate signal conditioning of the current measurements to improve the accuracy and reliability of wind turbine CMFD; (3) Developed a 1P-invariant power spectrum density (PSD) method for effective signature extraction of wind turbine faults with characteristic frequencies in the current or current demodulated signals, where 1P stands for the shaft rotating frequency of a WTG; (4) Developed a wavelet filter for effective signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (5) Developed an effective adaptive noise cancellation method as an alternative to the wavelet filter method for signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (6) Developed a statistical analysis-based impulse detection method for effective fault signature extraction and evaluation of WTGs based on the 1P-invariant PSD of the current or current demodulated signals; (7) Validated the proposed current-based wind turbine CMFD technologies through extensive computer simulations and experiments for small direct-drive WTGs without gearboxes; and (8) Showed, through extensive experiments for small direct-drive WTGs, that the performance of the proposed current-based wind turbine CMFD technologies is comparable to traditional vibration-based methods. The proposed technologies have been successfully applied for detection of major failures in blades, shafts, bearings, and generators of small direct-drive WTGs. The proposed technologies can be easily integrated into existing wind turbine control, protection, and monitoring systems and can be implemented remotely from the wind turbines being monitored. The proposed technologies provide an alternative to vibration-sensor-based CMFD. This will reduce the cost and hardware complexity of wind turbine CMFD systems. The proposed technologies can also be combined with vibration-sensor-based methods to improve the accuracy and reliability of wind turbine CMFD systems. When there are problems with sensors, the proposed technologies will ensure proper CMFD for the wind turbines, including their sensing systems. In conclusion, the proposed technologies offer an effective means to achieve condition-based smart maintenance for wind turbines and have a great potential to be adopted by the wind energy industry due to their almost no-cost, nonintrusive features. Although only validated for small direct-drive wind turbines without gearboxes, the proposed technologies are also applicable for CMFD of large-size wind turbines with and without gearboxes. However, additional investigations are recommended in order to apply the proposed technologies to those large-size wind turbines.« less

  4. Amoeba-related health risk in drinking water systems: could monitoring of amoebae be a complementary approach to current quality control strategies?

    PubMed

    Codony, Francesc; Pérez, Leonardo Martín; Adrados, Bárbara; Agustí, Gemma; Fittipaldi, Mariana; Morató, Jordi

    2012-01-01

    Culture-based methods for fecal indicator microorganisms are the standard protocol to assess potential health risk from drinking water systems. However, these traditional fecal indicators are inappropriate surrogates for disinfection-resistant fecal pathogens and the indigenous pathogens that grow in drinking water systems. There is now a range of molecular-based methods, such as quantitative PCR, which allow detection of a variety of pathogens and alternative indicators. Hence, in addition to targeting total Escherichia coli (i.e., dead and alive) for the detection of fecal pollution, various amoebae may be suitable to indicate the potential presence of pathogenic amoeba-resisting microorganisms, such as Legionellae. Therefore, monitoring amoeba levels by quantitative PCR could be a useful tool for directly and indirectly evaluating health risk and could also be a complementary approach to current microbial quality control strategies for drinking water systems.

  5. Costing 'healthy' food baskets in Australia - a systematic review of food price and affordability monitoring tools, protocols and methods.

    PubMed

    Lewis, Meron; Lee, Amanda

    2016-11-01

    To undertake a systematic review to determine similarities and differences in metrics and results between recently and/or currently used tools, protocols and methods for monitoring Australian healthy food prices and affordability. Electronic databases of peer-reviewed literature and online grey literature were systematically searched using the PRISMA approach for articles and reports relating to healthy food and diet price assessment tools, protocols, methods and results that utilised retail pricing. National, state, regional and local areas of Australia from 1995 to 2015. Assessment tools, protocols and methods to measure the price of 'healthy' foods and diets. The search identified fifty-nine discrete surveys of 'healthy' food pricing incorporating six major food pricing tools (those used in multiple areas and time periods) and five minor food pricing tools (those used in a single survey area or time period). Analysis demonstrated methodological differences regarding: included foods; reference households; use of availability and/or quality measures; household income sources; store sampling methods; data collection protocols; analysis methods; and results. 'Healthy' food price assessment methods used in Australia lack comparability across all metrics and most do not fully align with a 'healthy' diet as recommended by the current Australian Dietary Guidelines. None have been applied nationally. Assessment of the price, price differential and affordability of healthy (recommended) and current (unhealthy) diets would provide more robust and meaningful data to inform health and fiscal policy in Australia. The INFORMAS 'optimal' approach provides a potential framework for development of these methods.

  6. Glucose Measurement: Time for a Gold Standard

    PubMed Central

    Hagvik, Joakim

    2007-01-01

    There is no internationally recognized reference method for the measurement of blood glucose. The Centers for Disease Control and Prevention (CDC) highlighted the need for standardization some years ago when a project was started. The project objectives were to (1) investigate whether there are significant differences in calibration levels among currently used glucose monitors for home use and (2) develop a reference method for glucose determination. A first study confirmed the assumption that currently used home-use monitors differ significantly and that standardization is necessary in order to minimize variability and to improve patient care. As a reference method, CDC recommended a method based on isotope dilution gas chromatography–mass spectrometry, an assay that has received support from clinical chemists worldwide. CDC initiated a preliminary study to establish the suitability of this method, but then the project came to a halt. It is hoped that CDC, with support from the industry, as well as academic and professional organizations such as the American Association for Clinical Chemistry and International Federation of Clinical Chemistry and Laboratory Medicine, will be able to finalize the project and develop the long-awaited and much needed “gold standard” for glucose measurement. PMID:19888402

  7. Preliminary Evaluation of Method to Monitor Landfills Resilience against Methane Emission

    NASA Astrophysics Data System (ADS)

    Chusna, Noor Amalia; Maryono, Maryono

    2018-02-01

    Methane emission from landfill sites contribute to global warming and un-proper methane treatment can pose an explosion hazard. Stakeholder and government in the cities in Indonesia been found significant difficulties to monitor the resilience of landfill from methane emission. Moreover, the management of methane gas has always been a challenging issue for long waste management service and operations. Landfills are a significant contributor to anthropogenic methane emissions. This study conducted preliminary evaluation of method to manage methane gas emission by assessing LandGem and IPCC method. From the preliminary evaluation, this study found that the IPCC method is based on the availability of current and historical country specific data regarding the waste disposed of in landfills while from the LandGEM method is an automated tool for estimating emission rates for total landfill gas this method account total gas of methane, carbon dioxide and other. The method can be used either with specific data to estimate emissions in the site or default parameters if no site-specific data are available. Both of method could be utilize to monitor the methane emission from landfill site in cities of Central Java.

  8. Analyses of the most influential factors for vibration monitoring of planetary power transmissions in pellet mills by adaptive neuro-fuzzy technique

    NASA Astrophysics Data System (ADS)

    Milovančević, Miloš; Nikolić, Vlastimir; Anđelković, Boban

    2017-01-01

    Vibration-based structural health monitoring is widely recognized as an attractive strategy for early damage detection in civil structures. Vibration monitoring and prediction is important for any system since it can save many unpredictable behaviors of the system. If the vibration monitoring is properly managed, that can ensure economic and safe operations. Potentials for further improvement of vibration monitoring lie in the improvement of current control strategies. One of the options is the introduction of model predictive control. Multistep ahead predictive models of vibration are a starting point for creating a successful model predictive strategy. For the purpose of this article, predictive models of are created for vibration monitoring of planetary power transmissions in pellet mills. The models were developed using the novel method based on ANFIS (adaptive neuro fuzzy inference system). The aim of this study is to investigate the potential of ANFIS for selecting the most relevant variables for predictive models of vibration monitoring of pellet mills power transmission. The vibration data are collected by PIC (Programmable Interface Controller) microcontrollers. The goal of the predictive vibration monitoring of planetary power transmissions in pellet mills is to indicate deterioration in the vibration of the power transmissions before the actual failure occurs. The ANFIS process for variable selection was implemented in order to detect the predominant variables affecting the prediction of vibration monitoring. It was also used to select the minimal input subset of variables from the initial set of input variables - current and lagged variables (up to 11 steps) of vibration. The obtained results could be used for simplification of predictive methods so as to avoid multiple input variables. It was preferable to used models with less inputs because of overfitting between training and testing data. While the obtained results are promising, further work is required in order to get results that could be directly applied in practice.

  9. The Large Ring Laser G for Continuous Earth Rotation Monitoring

    NASA Astrophysics Data System (ADS)

    Schreiber, K. U.; Klügel, T.; Velikoseltsev, A.; Schlüter, W.; Stedman, G. E.; Wells, J.-P. R.

    2009-09-01

    Ring Laser gyroscopes exploit the Sagnac effect and measure rotations absolute. They do not require an external reference frame and therefore provide an independent method to monitor Earth rotation. Large-scale versions of these gyroscopes promise to eventually provide a similar high resolution for the measurement of the variations in the Earth rotation rate as the established methods based on VLBI and GNSS. This would open the door to a continuous monitoring of LOD (Length of Day) and polar motion, which is not yet available today. Another advantage is the access to the sub-daily frequency regime of Earth rotation. The ring laser “G” (Grossring), located at the Geodetic Observatory Wettzell (Germany) is the most advanced realization of such a large gyroscope. This paper outlines the current sensor design and properties.

  10. Evaluation of Content-Matched Range Monitoring Queries over Moving Objects in Mobile Computing Environments

    PubMed Central

    Jung, HaRim; Song, MoonBae; Youn, Hee Yong; Kim, Ung Mo

    2015-01-01

    A content-matched (CM) range monitoring query over moving objects continually retrieves the moving objects (i) whose non-spatial attribute values are matched to given non-spatial query values; and (ii) that are currently located within a given spatial query range. In this paper, we propose a new query indexing structure, called the group-aware query region tree (GQR-tree) for efficient evaluation of CM range monitoring queries. The primary role of the GQR-tree is to help the server leverage the computational capabilities of moving objects in order to improve the system performance in terms of the wireless communication cost and server workload. Through a series of comprehensive simulations, we verify the superiority of the GQR-tree method over the existing methods. PMID:26393613

  11. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed Central

    Chouler, Jon; Di Lorenzo, Mirella

    2015-01-01

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries. PMID:26193327

  12. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed

    Chouler, Jon; Di Lorenzo, Mirella

    2015-07-16

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries.

  13. Applicability of interferometric SAR technology to ground movement and pipeline monitoring

    NASA Astrophysics Data System (ADS)

    Grivas, Dimitri A.; Bhagvati, Chakravarthy; Schultz, B. C.; Trigg, Alan; Rizkalla, Moness

    1998-03-01

    This paper summarizes the findings of a cooperative effort between NOVA Gas Transmission Ltd. (NGTL), the Italian Natural Gas Transmission Company (SNAM), and Arista International, Inc., to determine whether current remote sensing technologies can be utilized to monitor small-scale ground movements over vast geographical areas. This topic is of interest due to the potential for small ground movements to cause strain accumulation in buried pipeline facilities. Ground movements are difficult to monitor continuously, but their cumulative effect over time can have a significant impact on the safety of buried pipelines. Interferometric synthetic aperture radar (InSAR or SARI) is identified as the most promising technique of those considered. InSAR analysis involves combining multiple images from consecutive passes of a radar imaging platform. The resulting composite image can detect changes as small as 2.5 to 5.0 centimeters (based on current analysis methods and radar satellite data of 5 centimeter wavelength). Research currently in progress shows potential for measuring ground movements as small as a few millimeters. Data needed for InSAR analysis is currently commercially available from four satellites, and additional satellites are planned for launch in the near future. A major conclusion of the present study is that InSAR technology is potentially useful for pipeline integrity monitoring. A pilot project is planned to test operational issues.

  14. [Blood pressure targets : The lower the better does not suit all].

    PubMed

    Hoffmann, U

    2018-04-01

    The systolic blood pressure intervention trial (SPRINT) published in 2015 has opened up new discussions on whether a lower blood pressure target as recommended by the current guidelines would be better for some patient groups. To review patient groups in which lower blood pressure targets would not be better. The results of SPRINT, its post-hoc and subgroup analyses, other studies and newer studies, as well as metaanalyses on the topic of blood pressure targets are reviewed and discussed. Studies with patients excluded from the SPRINT study were also analysed. The current international guidelines and recommendations of the Deutsche Hochdruckliga e. V. DHL® are included. Blood pressure monitoring methods differed considerably in the previously published studies. The low blood pressure value in SPRINT was mainly achieved due to the unusual method of blood pressure monitoring used and, as such, cannot be compared with blood pressure values in other studies. Based on current evidence, "the lower the better" should not be recommended in the following patient groups: older patients, in particular infirm older patients, patients with diabetes, patients without coronary heart disease or with low cardiovascular risk. When determining a blood pressure target, the method of blood pressure monitoring should be defined. A lower blood pressure target has been shown to be better in some well defined patient groups. However, adverse events due to antihypertensive medications should always be taken into account. Given the multiple exclusion criteria in trials and the results of many studies, "new" lower blood pressure targets could not be recommended in a large population of patients.

  15. Optimisation of techniques for quantification of Botrytis cinerea in grape berries and receptacles by quantitative polymerase chain reaction

    USDA-ARS?s Scientific Manuscript database

    Quantitative PCR (qPCR) can be used to detect and monitor pathogen colonization, but early attempts to apply the technology to Botrytis cinerea infection of grape berries have identified limitations to current techniques. In this study, four DNA extraction methods, two grinding methods, two grape or...

  16. A Disposable Microfluidic Device with a Screen Printed Electrode for Mimicking Phase II Metabolism

    PubMed Central

    Vasiliadou, Rafaela; Nasr Esfahani, Mohammad Mehdi; Brown, Nathan J.; Welham, Kevin J.

    2016-01-01

    Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler and a cheaper alternative to mimic the human metabolism. This paper describes the development of a disposable microfluidic device with a screen-printed electrode (SPE) for monitoring phase II GSH reactions. The proposed chip has the potential to be used as a primary screening tool, thus complementing the current in vitro methods. PMID:27598162

  17. Feasibility Study of a Rotorcraft Health and Usage Monitoring System (HUMS): Usage and Structural Life Monitoring Evaluation

    NASA Technical Reports Server (NTRS)

    Dickson, B.; Cronkhite, J.; Bielefeld, S.; Killian, L.; Hayden, R.

    1996-01-01

    The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FIS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques.

  18. LANDSCAPE CHARACTERIZATION AND CHANGE DETECTION METHODS DEVELOPMENT RESEARCH (2005-2007)

    EPA Science Inventory

    The characterization of land-cover (LC) type, extent, and distribution represent important landscape characterization element required for monitoring ecosystem conditions and for primary data input to biogenic emission and atmospheric deposition models. Current spectral-based ch...

  19. 33 CFR 106.205 - Company Security Officer (CSO).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Methods of conducting audits, inspection, control, and monitoring; and (7) Techniques for security... security related communications; (7) Knowledge of current security threats and patterns; (8) Recognition and detection of dangerous substances and devices; (9) Recognition of characteristics and behavioral...

  20. 33 CFR 106.205 - Company Security Officer (CSO).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Methods of conducting audits, inspection, control, and monitoring; and (7) Techniques for security... security related communications; (7) Knowledge of current security threats and patterns; (8) Recognition and detection of dangerous substances and devices; (9) Recognition of characteristics and behavioral...

  1. 33 CFR 106.205 - Company Security Officer (CSO).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Methods of conducting audits, inspection, control, and monitoring; and (7) Techniques for security... security related communications; (7) Knowledge of current security threats and patterns; (8) Recognition and detection of dangerous substances and devices; (9) Recognition of characteristics and behavioral...

  2. SITE-SPECIFIC DIAGNOSTIC TOOLS

    EPA Science Inventory

    US EPA's Office of Water is proposing Combined Assessment and Listing Methods (CALM) to
    meet reporting requirements under both Sections 305b and 303d for chemical and nonchemical
    stressors in the nation's waterbodies. Current Environmental Monitoring and Assessment
    Prog...

  3. Cost-effective water quality assessment through the integration of monitoring data and modeling results

    NASA Astrophysics Data System (ADS)

    Lobuglio, Joseph N.; Characklis, Gregory W.; Serre, Marc L.

    2007-03-01

    Sparse monitoring data and error inherent in water quality models make the identification of waters not meeting regulatory standards uncertain. Additional monitoring can be implemented to reduce this uncertainty, but it is often expensive. These costs are currently a major concern, since developing total maximum daily loads, as mandated by the Clean Water Act, will require assessing tens of thousands of water bodies across the United States. This work uses the Bayesian maximum entropy (BME) method of modern geostatistics to integrate water quality monitoring data together with model predictions to provide improved estimates of water quality in a cost-effective manner. This information includes estimates of uncertainty and can be used to aid probabilistic-based decisions concerning the status of a water (i.e., impaired or not impaired) and the level of monitoring needed to characterize the water for regulatory purposes. This approach is applied to the Catawba River reservoir system in western North Carolina as a means of estimating seasonal chlorophyll a concentration. Mean concentration and confidence intervals for chlorophyll a are estimated for 66 reservoir segments over an 11-year period (726 values) based on 219 measured seasonal averages and 54 model predictions. Although the model predictions had a high degree of uncertainty, integration of modeling results via BME methods reduced the uncertainty associated with chlorophyll estimates compared with estimates made solely with information from monitoring efforts. Probabilistic predictions of future chlorophyll levels on one reservoir are used to illustrate the cost savings that can be achieved by less extensive and rigorous monitoring methods within the BME framework. While BME methods have been applied in several environmental contexts, employing these methods as a means of integrating monitoring and modeling results, as well as application of this approach to the assessment of surface water monitoring networks, represent unexplored areas of research.

  4. Apparatus and method for critical current measurements

    DOEpatents

    Martin, Joe A.; Dye, Robert C.

    1992-01-01

    An apparatus for the measurement of the critical current of a superconductive sample, e.g., a clad superconductive sample, the apparatus including a conductive coil, a means for maintaining the coil in proximity to a superconductive sample, an electrical connection means for passing a low amplitude alternating current through the coil, a cooling means for maintaining the superconductive sample at a preselected temperature, a means for passing a current through the superconductive sample, and, a means for monitoring reactance of the coil, is disclosed, together with a process of measuring the critical current of a superconductive material, e.g., a clad superconductive material, by placing a superconductive material into the vicinity of the conductive coil of such an apparatus, cooling the superconductive material to a preselected temperature, passing a low amplitude alternating current through the coil, the alternating current capable of generating a magnetic field sufficient to penetrate, e.g., any cladding, and to induce eddy currents in the superconductive material, passing a steadily increasing current through the superconductive material, the current characterized as having a different frequency than the alternating current, and, monitoring the reactance of the coil with a phase sensitive detector as the current passed through the superconductive material is steadily increased whereby critical current of the superconductive material can be observed as the point whereat a component of impedance deviates.

  5. Real-time electrochemical monitoring of isothermal helicase-dependent amplification of nucleic acids.

    PubMed

    Kivlehan, Francine; Mavré, François; Talini, Luc; Limoges, Benoît; Marchal, Damien

    2011-09-21

    We described an electrochemical method to monitor in real-time the isothermal helicase-dependent amplification of nucleic acids. The principle of detection is simple and well-adapted to the development of portable, easy-to-use and inexpensive nucleic acids detection technologies. It consists of monitoring a decrease in the electrochemical current response of a reporter DNA intercalating redox probe during the isothermal DNA amplification. The method offers the possibility to quantitatively analyze target nucleic acids in less than one hour at a single constant temperature, and to perform at the end of the isothermal amplification a DNA melt curve analysis for differentiating between specific and non-specific amplifications. To illustrate the potentialities of this approach for the development of a simple, robust and low-cost instrument with high throughput capability, the method was validated with an electrochemical system capable of monitoring up to 48 real-time isothermal HDA reactions simultaneously in a disposable microplate consisting of 48-electrochemical microwells. Results obtained with this approach are comparable to that obtained with a well-established but more sophisticated and expensive fluorescence-based method. This makes for a promising alternative detection method not only for real-time isothermal helicase-dependent amplification of nucleic acid, but also for other isothermal DNA amplification strategies.

  6. Current practices in laboratory monitoring of HIV infection

    PubMed Central

    Vajpayee, Madhu; Mohan, Teena

    2011-01-01

    After a diagnosis of HIV infection is made, the patient needs to be monitored using both clinical assessment and laboratory markers. HIV/AIDS monitoring is essential in guiding when to recommend initiation of therapy. Clinical monitoring will include staging of the HIV/AIDS disease using either the presence or absence of HIV-related signs and symptoms using the WHO staging system. Various laboratory methods can be used to monitor the disease progression and to guide whether the patient will need antiretroviral therapy or not. Laboratory monitoring for patients who are not on drugs is done to provide information about the stage of illness; to enable the clinician to make decisions on treatment and to give information on prognosis of the patient. Patients on drugs are monitored to assess their response to treatment with antiretroviral drugs and to detect any possible toxicity and improvement associated with the antiretroviral drugs. PMID:22310815

  7. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    PubMed

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  8. Wrist sensor for warfighter status monitor

    NASA Astrophysics Data System (ADS)

    Chen, Wuping

    2000-04-01

    There is a pressing need to improve human status monitoring in the medical and military communities. The heart rate and breading rate are the most important human vital signs. The current heart rate and breading rate monitors are rather cumbersome, expensive, and usually confined to the intensive care unit or ambulatory setting. These techniques are therefore unavailable to certain applications, such as home care and military applications. The purpose of this work is to develop new methods and new technologies for heart rate and breathing rate monitoring. To accomplish this task, a novel optical acoustic laser sensor (OALS) is characterized and used to generate an optical signal corresponding to human heart beat and breathing. An application specific integrated circuit (ASIC) is developed for this unique compact human status monitor Extensive experimental data analysis and simulation are conducted to investigate robust digital signal processing (DSP) methods. The Gauss-Hermite wavelet transform (GHWT) is utilized as a time-frequency representative technique to provide a method for the detection of the very low frequency heart rate and breathing rate from the large and noisy biomedical lasergram (BLG) signal. A 915MHz RF transceiver provides a reliable wireless link for the monitor to receive commands or transmit the measurement results to a remote commander center. A complete micro-instrument based on the ideas and methods above are developed and tested. The results show that the heart rate and breathing rate could be measured under difficult environmental situations.

  9. Method of monitoring CO concentrations in hydrogen feed to a PEM fuel cell

    DOEpatents

    Grot, Stephen Andreas; Meltser, Mark Alexander; Gutowski, Stanley; Neutzler, Jay Kevin; Borup, Rodney Lynn; Weisbrod, Kirk

    2000-01-01

    The CO concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and/or voltage behavior patterns from a PEM-probe communicating with the reformate feed stream. Pattern recognition software may be used to compare the current and voltage patterns from the PEM-probe to current and voltage telltale outputs determined from a reference cell similar to the PEM-probe and operated under controlled conditions over a wide range of CO concentrations in the H.sub.2 fuel stream. The PEM-probe is intermittently purged of any CO build-up on the anode catalyst (e.g., by (1) flushing the anode with air, (2) short circuiting the PEM-probe, or (3) reverse biasing the PEM-probe) to keep the PEM-probe at peak performance levels.

  10. Women's experiences of continuous fetal monitoring - a mixed-methods systematic review.

    PubMed

    Crawford, Alexandra; Hayes, Dexter; Johnstone, Edward D; Heazell, Alexander E P

    2017-12-01

    Antepartum stillbirth is often preceded by detectable signs of fetal compromise, including changes in fetal heart rate and movement. It is hypothesized that continuous fetal monitoring could detect these signs more accurately and objectively than current forms of fetal monitoring and allow for timely intervention. This systematic review aimed to explore available evidence on women's experiences of continuous fetal monitoring to investigate its acceptability before clinical implementation and to inform clinical studies. Systematic searching of four electronic databases (Embase, PsycINFO, MEDLINE and CINAHL), using key terms defined by initial scoping searches, identified a total of 35 studies. Following title and abstract screening by two independent researchers, five studies met the inclusion criteria. Studies were not excluded based on language, methodology or quality assessment. An integrative methodology was used to synthesize qualitative and quantitative data together. Forms of continuous fetal monitoring used included Monica AN24 monitors (n = 4) and phonocardiography (n = 1). Four main themes were identified: practical limitations of the device, negative emotions, positive perceptions, and device implementation. Continuous fetal monitoring was reported to have high levels of participant satisfaction and was preferred by women to intermittent cardiotocography. This review suggests that continuous fetal monitoring is accepted by women. However, it has also highlighted both the paucity and heterogeneity of current studies and suggests that further research should be conducted into women's experiences of continuous fetal monitoring before such devices can be used clinically. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  11. Characterization of electrical appliances in transient state

    NASA Astrophysics Data System (ADS)

    Wójcik, Augustyn; Winiecki, Wiesław

    2017-08-01

    The article contains the study about electrical appliance characterization on the basis of power grid signals. To represent devices, parameters of current and voltage signals recorded during transient states are used. In this paper only transients occurring as a result of switching on devices are considered. The way of data acquisition performed in specialized measurement setup developed for electricity load monitoring is described. The paper presents the method of transients detection and the method of appliance parameters calculation. Using the set of acquired measurement data and appropriate software the set of parameters for several household appliances operating in different operating conditions was processed. Usefulness of appliances characterization in Non-Intrusive Appliance Load Monitoring System (NIALMS) with the use of proposed method is discussed focusing on obtained results.

  12. Monitoring diesel particulate matter and calculating diesel particulate densities using Grimm model 1.109 real-time aerosol monitors in underground mines.

    PubMed

    Kimbal, Kyle C; Pahler, Leon; Larson, Rodney; VanDerslice, Jim

    2012-01-01

    Currently, there is no Mine Safety and Health Administration (MSHA)-approved sampling method that provides real-time results for ambient concentrations of diesel particulates. This study investigated whether a commercially available aerosol spectrometer, the Grimm Portable Aerosol Spectrometer Model 1.109, could be used during underground mine operations to provide accurate real-time diesel particulate data relative to MSHA-approved cassette-based sampling methods. A subset was to estimate size-specific diesel particle densities to potentially improve the diesel particulate concentration estimates using the aerosol monitor. Concurrent sampling was conducted during underground metal mine operations using six duplicate diesel particulate cassettes, according to the MSHA-approved method, and two identical Grimm Model 1.109 instruments. Linear regression was used to develop adjustment factors relating the Grimm results to the average of the cassette results. Statistical models using the Grimm data produced predicted diesel particulate concentrations that highly correlated with the time-weighted average cassette results (R(2) = 0.86, 0.88). Size-specific diesel particulate densities were not constant over the range of particle diameters observed. The variance of the calculated diesel particulate densities by particle diameter size supports the current understanding that diesel emissions are a mixture of particulate aerosols and a complex host of gases and vapors not limited to elemental and organic carbon. Finally, diesel particulate concentrations measured by the Grimm Model 1.109 can be adjusted to provide sufficiently accurate real-time air monitoring data for an underground mining environment.

  13. Application of excitation and emission matrix fluorescence (EEM) and UV-vis absorption to monitor the characteristics of Alizarin Red S (ARS) during electro-Fenton degradation process.

    PubMed

    Lai, Bo; Zhou, Yuexi; Wang, Juling; Yang, Zhishan; Chen, Zhiqiang

    2013-11-01

    Oxidative degradation of Alizarin Red S (ARS) in aqueous solutions by using electro-Fenton was studied. At first, effect of operating parameters such as current density, aeration rate and initial pH on the degradation of ARS were studied by using UV-vis spectrum, respectively. Then, under the optimal operating conditions (current density: 10.0mAcm(-2), aeration rate: 1000mLmin(-1), initial pH: 2.8), the identification of degradation products of ARS was carried out by using GC-MS and HPLC, meanwhile its degradation pathway was proposed according to the intermediates. Considering the location, intensity and intensity ratio of fluorescence center peak of the ARS in aqueous solution, a convenient and quick monitoring method by using excitation-emission matrix fluorescence spectrum technology was developed to monitor the degradation degree of ARS through electro-Fenton process. Furthermore, it is suggested that the developed method would be promising for the quick analysis and evaluation of the degradation degree of the pollutants with π-conjugated system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Quantification of Peptides from Immunoglobulin Constant and Variable Regions by Liquid Chromatography-Multiple Reaction Monitoring Mass Spectrometry for Assessment of Multiple Myeloma Patients

    PubMed Central

    Remily-Wood, Elizabeth R.; Benson, Kaaron; Baz, Rachid C.; Chen, Y. Ann; Hussein, Mohamad; Hartley-Brown, Monique A.; Sprung, Robert W.; Perez, Brianna; Liu, Richard Z.; Yoder, Sean; Teer, Jamie; Eschrich, Steven A.; Koomen, John M.

    2014-01-01

    Purpose Quantitative mass spectrometry assays for immunoglobulins (Igs) are compared with existing clinical methods in samples from patients with plasma cell dyscrasias, e.g. multiple myeloma. Experimental design Using LC-MS/MS data, Ig constant region peptides and transitions were selected for liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM). Quantitative assays were used to assess Igs in serum from 83 patients. Results LC-MRM assays quantify serum levels of Igs and their isoforms (IgG1–4, IgA1–2, IgM, IgD, and IgE, as well as kappa(κ) and lambda(λ) light chains). LC-MRM quantification has been applied to single samples from a patient cohort and a longitudinal study of an IgE patient undergoing treatment, to enable comparison with existing clinical methods. Proof-of-concept data for defining and monitoring variable region peptides are provided using the H929 multiple myeloma cell line and two MM patients. Conclusions and Clinical Relevance LC-MRM assays targeting constant region peptides determine the type and isoform of the involved immunoglobulin and quantify its expression; the LC-MRM approach has improved sensitivity compared with the current clinical method, but slightly higher interassay variability. Detection of variable region peptides is a promising way to improve Ig quantification, which could produce a dramatic increase in sensitivity over existing methods, and could further complement current clinical techniques. PMID:24723328

  15. Google Earth Engine: a new cloud-computing platform for global-scale earth observation data and analysis

    NASA Astrophysics Data System (ADS)

    Moore, R. T.; Hansen, M. C.

    2011-12-01

    Google Earth Engine is a new technology platform that enables monitoring and measurement of changes in the earth's environment, at planetary scale, on a large catalog of earth observation data. The platform offers intrinsically-parallel computational access to thousands of computers in Google's data centers. Initial efforts have focused primarily on global forest monitoring and measurement, in support of REDD+ activities in the developing world. The intent is to put this platform into the hands of scientists and developing world nations, in order to advance the broader operational deployment of existing scientific methods, and strengthen the ability for public institutions and civil society to better understand, manage and report on the state of their natural resources. Earth Engine currently hosts online nearly the complete historical Landsat archive of L5 and L7 data collected over more than twenty-five years. Newly-collected Landsat imagery is downloaded from USGS EROS Center into Earth Engine on a daily basis. Earth Engine also includes a set of historical and current MODIS data products. The platform supports generation, on-demand, of spatial and temporal mosaics, "best-pixel" composites (for example to remove clouds and gaps in satellite imagery), as well as a variety of spectral indices. Supervised learning methods are available over the Landsat data catalog. The platform also includes a new application programming framework, or "API", that allows scientists access to these computational and data resources, to scale their current algorithms or develop new ones. Under the covers of the Google Earth Engine API is an intrinsically-parallel image-processing system. Several forest monitoring applications powered by this API are currently in development and expected to be operational in 2011. Combining science with massive data and technology resources in a cloud-computing framework can offer advantages of computational speed, ease-of-use and collaboration, as well as transparency in data and methods. Methods developed for global processing of MODIS data to map land cover are being adopted for use with Landsat data. Specifically, the MODIS Vegetation Continuous Field product methodology has been applied for mapping forest extent and change at national scales using Landsat time-series data sets. Scaling this method to continental and global scales is enabled by Google Earth Engine computing capabilities. By combining the supervised learning VCF approach with the Landsat archive and cloud computing, unprecedented monitoring of land cover dynamics is enabled.

  16. Off-line wafer level reliability control: unique measurement method to monitor the lifetime indicator of gate oxide validated within bipolar/CMOS/DMOS technology

    NASA Astrophysics Data System (ADS)

    Gagnard, Xavier; Bonnaud, Olivier

    2000-08-01

    We have recently published a paper on a new rapid method for the determination of the lifetime of the gate oxide involved in a Bipolar/CMOS/DMOS technology (BCD). Because this previous method was based on a current measurement with gate voltage as a parameter needing several stress voltages, it was applied only by lot sampling. Thus, we tried to find an indicator in order to monitor the gate oxide lifetime during the wafer level parametric test and involving only one measurement of the device on each wafer test cell. Using the Weibull law and Crook model, combined with our recent model, we have developed a new test method needing only one electrical measurement of MOS capacitor to monitor the quality of the gate oxide. Based also on a current measurement, the parameter is the lifetime indicator of the gate oxide. From the analysis of several wafers, we gave evidence of the possibility to detect a low performance wafer, which corresponds to the infantile failure on the Weibull plot. In order to insert this new method in the BCD parametric program, a parametric flowchart was established. This type of measurement is an important challenges, because the actual measurements, breakdown charge, Qbd, and breakdown electric field, Ebd, at parametric level and Ebd and interface states density, Dit during the process cannot guarantee the gate oxide lifetime all along fabrication process. This indicator measurement is the only one, which predicts the lifetime decrease.

  17. Self-Field-Dominated Plasma

    DTIC Science & Technology

    1998-03-31

    plasma focus discharges. Part of the tests summarized here address methods and means for achieving controlled variations of the current sheath (CS) structure via electrode geometry modifications. CS parameters are monitored with multiple magnetic probes in the case of cylindrical - and open-funnel electrode

  18. A new method for determining a sector alert

    DOT National Transportation Integrated Search

    2008-09-29

    The Traffic Flow Management System (TFMS) currently declares an alert for any 15-minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP) for any airport, sector, or fix. For a sector, TFMS predicts the demand for each ...

  19. Monitoring inflammation (including fever) in acute brain injury.

    PubMed

    Provencio, J Javier; Badjatia, Neeraj

    2014-12-01

    Inflammation is an important part of the normal physiologic response to acute brain injury (ABI). How inflammation is manifest determines if it augments or hinders the resolution of ABI. Monitoring body temperature, the cellular arm of the inflammatory cascade, and inflammatory proteins may help guide therapy. This summary will address the utility of inflammation monitoring in brain-injured adults. An electronic literature search was conducted for English language articles describing the testing, utility, and optimal methods to measure inflammation in ABI. Ninety-four articles were included in this review. Current evidence suggests that control of inflammation after ABI may hold promise for advances in good outcomes. However, our understanding of how much inflammation is good and how much is deleterious is not yet clear. Several important concepts emerge form our review. First, while continuous temperature monitoring of core body temperature is recommended, temperature pattern alone is not useful in distinguishing infectious from noninfectious fever. Second, when targeted temperature management is used, shivering should be monitored at least hourly. Finally, white blood cell levels and protein markers of inflammation may have a limited role in distinguishing infectious from noninfectious fever. Our understanding of optimal use of inflammation monitoring after ABI is limited currently but is an area of active investigation.

  20. Monitoring blood flow and photobleaching during topical ALA PDT treatment

    NASA Astrophysics Data System (ADS)

    Sands, Theresa L.; Sunar, Ulas; Foster, Thomas H.; Oseroff, Allan R.

    2009-02-01

    Photodynamic therapy (PDT) using topical aminolevulinic acid (ALA) is currently used as a clinical treatment for nonmelanoma skin cancers. In order to optimize PDT treatment, vascular shutdown early in treatment must be identified and prevented. This is especially important for topical ALA PDT where vascular shutdown is only temporary and is not a primary method of cell death. Shutdown in vasculature would limit the delivery of oxygen which is necessary for effective PDT treatment. Diffuse correlation spectroscopy (DCS) was used to monitor relative blood flow changes in Balb/C mice undergoing PDT at fluence rates of 10mW/cm2 and 75mW/cm2 for colon-26 tumors implanted intradermally. DCS is a preferable method to monitor the blood flow during PDT of lesions due to its ability to be used noninvasively throughout treatment, returning data from differing depths of tissue. Photobleaching of the photosensitizer was also monitored during treatment as an indirect manner of monitoring singlet oxygen production. In this paper, we show the conditions that cause vascular shutdown in our tumor model and its effects on the photobleaching rate.

  1. Future technologies for monitoring HIV drug resistance and cure.

    PubMed

    Parikh, Urvi M; McCormick, Kevin; van Zyl, Gert; Mellors, John W

    2017-03-01

    Sensitive, scalable and affordable assays are critically needed for monitoring the success of interventions for preventing, treating and attempting to cure HIV infection. This review evaluates current and emerging technologies that are applicable for both surveillance of HIV drug resistance (HIVDR) and characterization of HIV reservoirs that persist despite antiretroviral therapy and are obstacles to curing HIV infection. Next-generation sequencing (NGS) has the potential to be adapted into high-throughput, cost-efficient approaches for HIVDR surveillance and monitoring during continued scale-up of antiretroviral therapy and rollout of preexposure prophylaxis. Similarly, improvements in PCR and NGS are resulting in higher throughput single genome sequencing to detect intact proviruses and to characterize HIV integration sites and clonal expansions of infected cells. Current population genotyping methods for resistance monitoring are high cost and low throughput. NGS, combined with simpler sample collection and storage matrices (e.g. dried blood spots), has considerable potential to broaden global surveillance and patient monitoring for HIVDR. Recent adaptions of NGS to identify integration sites of HIV in the human genome and to characterize the integrated HIV proviruses are likely to facilitate investigations of the impact of experimental 'curative' interventions on HIV reservoirs.

  2. In-flight spectral performance monitoring of the Airborne Prism Experiment.

    PubMed

    D'Odorico, Petra; Alberti, Edoardo; Schaepman, Michael E

    2010-06-01

    Spectral performance of an airborne dispersive pushbroom imaging spectrometer cannot be assumed to be stable over a whole flight season given the environmental stresses present during flight. Spectral performance monitoring during flight is commonly accomplished by looking at selected absorption features present in the Sun, atmosphere, or ground, and their stability. The assessment of instrument performance in two different environments, e.g., laboratory and airborne, using precisely the same calibration reference, has not been possible so far. The Airborne Prism Experiment (APEX), an airborne dispersive pushbroom imaging spectrometer, uses an onboard in-flight characterization (IFC) facility, which makes it possible to monitor the sensor's performance in terms of spectral, radiometric, and geometric stability in flight and in the laboratory. We discuss in detail a new method for the monitoring of spectral instrument performance. The method relies on the monitoring of spectral shifts by comparing instrument-induced movements of absorption features on ground and in flight. Absorption lines originate from spectral filters, which intercept the full field of view (FOV) illuminated using an internal light source. A feature-fitting algorithm is used for the shift estimation based on Pearson's correlation coefficient. Environmental parameter monitoring, coregistered on board with the image and calibration data, revealed that differential pressure and temperature in the baffle compartment are the main driving parameters explaining the trend in spectral performance deviations in the time and the space (across-track) domains, respectively. The results presented in this paper show that the system in its current setup needs further improvements to reach a stable performance. Findings provided useful guidelines for the instrument revision currently under way. The main aim of the revision is the stabilization of the instrument for a range of temperature and pressure conditions to be encountered during operation.

  3. A meta-analysis of self-monitoring on reading performance of K-12 students.

    PubMed

    Guzman, Guadalupe; Goldberg, Taryn S; Swanson, H Lee

    2018-03-01

    The published single-case design (SCD) research (N = 19 articles) on self-monitoring and reading performance was synthesized. The following inclusion criteria were used: (a) the study must have been peer-reviewed, (b) implemented an intervention targeting student self-monitoring of reading skills, (c) included data on at least 1 reading outcome, (d) included visual representation of the data, and (f) the study must have used an SCD to assess the topic of interest. A total of 67 participants, 45 males and 22 females, ranging in age from 7:8 -18:7 were included in the current meta-analysis. Ethnicity was reported for 42 students: 23 were Caucasian, 12 were African American, and 7 were Latino/Hispanic. Studies were compared with those meeting What Works Clearinghouse (WWC) standards and those not meeting standards. The Tau-U effect size (ES) method was the main calculation method used; however, Phi ES estimates are included for comparison purposes. Results indicated that self-monitoring had an overall significant large positive effect on the reading performance of K-12 students, Tau-U = 0.79, 95% confidence interval (CI) [0.64, 0.93], p < .0001. However, self-monitoring for studies that met WWC criteria yielded a larger overall positive ES, Tau-U = 0.93, 95% CI [0.79, 1.07], p < .0001. Although the current meta-analysis is limited to peer-reviewed SCD studies, the findings provide support for self-monitoring as an evidence-based reading intervention for students in Grades K-12. Furthermore, findings indicate that larger ES values were identified when consolidating studies based on WWC guidelines as compared with consolidating across all studies. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Monitoring tigers with confidence.

    PubMed

    Linkie, Matthew; Guillera-Arroita, Gurutzeta; Smith, Joseph; Rayan, D Mark

    2010-12-01

    With only 5% of the world's wild tigers (Panthera tigris Linnaeus, 1758) remaining since the last century, conservationists urgently need to know whether or not the management strategies currently being employed are effectively protecting these tigers. This knowledge is contingent on the ability to reliably monitor tiger populations, or subsets, over space and time. In the this paper, we focus on the 2 seminal methodologies (camera trap and occupancy surveys) that have enabled the monitoring of tiger populations with greater confidence. Specifically, we: (i) describe their statistical theory and application in the field; (ii) discuss issues associated with their survey designs and state variable modeling; and, (iii) discuss their future directions. These methods have had an unprecedented influence on increasing statistical rigor within tiger surveys and, also, surveys of other carnivore species. Nevertheless, only 2 published camera trap studies have gone beyond single baseline assessments and actually monitored population trends. For low density tiger populations (e.g. <1 adult tiger/100 km(2)) obtaining sufficient precision for state variable estimates from camera trapping remains a challenge because of insufficient detection probabilities and/or sample sizes. Occupancy surveys have overcome this problem by redefining the sampling unit (e.g. grid cells and not individual tigers). Current research is focusing on developing spatially explicit capture-mark-recapture models and estimating abundance indices from landscape-scale occupancy surveys, as well as the use of genetic information for identifying and monitoring tigers. The widespread application of these monitoring methods in the field now enables complementary studies on the impact of the different threats to tiger populations and their response to varying management intervention. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  5. Labeling and Magnetic Resonance Imaging of Exosomes Isolated from Adipose Stem Cells.

    PubMed

    Busato, Alice; Bonafede, Roberta; Bontempi, Pietro; Scambi, Ilaria; Schiaffino, Lorenzo; Benati, Donatella; Malatesta, Manuela; Sbarbati, Andrea; Marzola, Pasquina; Mariotti, Raffaella

    2017-06-19

    Adipose stem cells (ASC) represent a promising therapeutic approach for neurodegenerative diseases. Most biological effects of ASC are probably mediated by extracellular vesicles, such as exosomes, which influence the surrounding cells. Current development of exosome therapies requires efficient and noninvasive methods to localize, monitor, and track the exosomes. Among imaging methods used for this purpose, magnetic resonance imaging (MRI) has advantages: high spatial resolution, rapid in vivo acquisition, and radiation-free operation. To be detectable with MRI, exosomes must be labeled with MR contrast agents, such as ultra-small superparamagnetic iron oxide nanoparticles (USPIO). Here, we set up an innovative approach for exosome labeling that preserves their morphology and physiological characteristics. We show that by labeling ASC with USPIO before extraction of nanovesicles, the isolated exosomes retain nanoparticles and can be visualized by MRI. The current work aims at validating this novel USPIO-based exosome labeling method by monitoring the efficiency of the labeling with MRI both in ASC and in exosomes. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  6. Monitoring the Softening of Aluminum-Alloy V95ochT2 Shapes by a Nondestructive Method

    NASA Astrophysics Data System (ADS)

    Shigapov, A. I.; Klimova, T. A.; Il'inkova, T. A.

    2015-09-01

    Correlation relations between the strength and the electrical conductivity of aluminum shapes are determined. The properties of alloy V95ochT2 are studied after different temperature-and-time actions. It is shown that the "dark spots" appearing on the surface of such shapes can be evaluated by a nondestructive eddy-current method.

  7. Integrated monitoring and assessment of soil restoration treatments in the Lake Tahoe Basin.

    PubMed

    Grismer, M E; Schnurrenberger, C; Arst, R; Hogan, M P

    2009-03-01

    Revegetation and soil restoration efforts, often associated with erosion control measures on disturbed soils, are rarely monitored or otherwise evaluated in terms of improved hydrologic, much less, ecologic function and longer term sustainability. As in many watersheds, sediment is a key parameter of concern in the Tahoe Basin, particularly fine sediments less than about ten microns. Numerous erosion control measures deployed in the Basin during the past several decades have under-performed, or simply failed after a few years and new soil restoration methods of erosion control are under investigation. We outline a comprehensive, integrated field-based evaluation and assessment of the hydrologic function associated with these soil restoration methods with the hypothesis that restoration of sustainable function will result in longer term erosion control benefits than that currently achieved with more commonly used surface treatment methods (e.g. straw/mulch covers and hydroseeding). The monitoring includes cover-point and ocular assessments of plant cover, species type and diversity; soil sampling for nutrient status; rainfall simulation measurement of infiltration and runoff rates; cone penetrometer measurements of soil compaction and thickness of mulch layer depths. Through multi-year hydrologic and vegetation monitoring at ten sites and 120 plots, we illustrate the results obtained from the integrated monitoring program and describe how it might guide future restoration efforts and monitoring assessments.

  8. Monitoring Butterfly Abundance: Beyond Pollard Walks

    PubMed Central

    Pellet, Jérôme; Bried, Jason T.; Parietti, David; Gander, Antoine; Heer, Patrick O.; Cherix, Daniel; Arlettaz, Raphaël

    2012-01-01

    Most butterfly monitoring protocols rely on counts along transects (Pollard walks) to generate species abundance indices and track population trends. It is still too often ignored that a population count results from two processes: the biological process (true abundance) and the statistical process (our ability to properly quantify abundance). Because individual detectability tends to vary in space (e.g., among sites) and time (e.g., among years), it remains unclear whether index counts truly reflect population sizes and trends. This study compares capture-mark-recapture (absolute abundance) and count-index (relative abundance) monitoring methods in three species (Maculinea nausithous and Iolana iolas: Lycaenidae; Minois dryas: Satyridae) in contrasted habitat types. We demonstrate that intraspecific variability in individual detectability under standard monitoring conditions is probably the rule rather than the exception, which questions the reliability of count-based indices to estimate and compare specific population abundance. Our results suggest that the accuracy of count-based methods depends heavily on the ecology and behavior of the target species, as well as on the type of habitat in which surveys take place. Monitoring programs designed to assess the abundance and trends in butterfly populations should incorporate a measure of detectability. We discuss the relative advantages and inconveniences of current monitoring methods and analytical approaches with respect to the characteristics of the species under scrutiny and resources availability. PMID:22859980

  9. Vaginal Electrohysterography: The Design and Preliminary Evaluation of a Novel Device for Uterine Contraction Monitoring in an Ovine Model

    PubMed Central

    SUNWOO, Nate; HWANG, Karin; BLAKEMORE, Karin; AINA-MUMUNEY, Abimbola

    2016-01-01

    Objective Tocodynamometry is the most common method of labor evaluation but most clinicians would agree it has limited utility before 26 weeks gestation. The obesity epidemic has further reduced our ability to accurately detect uterine contractions using the tocodynamometer at any gestational age. We sought to design and test a novel contraction monitor that bypasses the maternal abdomen. Methods An optimized version of an intravaginal electrohysterographic ring device was tested in an ovine model. The device and its methodology as well as the tocodynamometer were validated against the current gold standard uterine activity monitor, the intrauterine pressure catheter in 6 sheep at varying gestational ages. Results Both the intravaginal ring device and the tocodynamometer correlated well with IUPC, r = 0.69 and 0.73 respectively (p<0.001). The number of contractions detected by each monitor remained similar even after accounting for confounders. Conclusions These results suggest that uterine activity can be monitored from the vaginal interface in an ovine model and offers an alternative clinical tool for the detection of contractions in situations in which tocodynamometry would be ineffective or intrauterine monitoring inappropriate. PMID:26458732

  10. Coliform Bacteria Monitoring in Fish Systems: Current Practices in Public Aquaria.

    PubMed

    Culpepper, Erin E; Clayton, Leigh A; Hadfield, Catherine A; Arnold, Jill E; Bourbon, Holly M

    2016-06-01

    Public aquaria evaluate coliform indicator bacteria levels in fish systems, but the purpose of testing, testing methods, and management responses are not standardized, unlike with the coliform bacteria testing for marine mammal enclosures required by the U.S. Department of Agriculture. An online survey was sent to selected aquaria to document current testing and management practices in fish systems without marine mammals. The information collected included indicator bacteria species, the size and type of systems monitored, the primary purpose of testing, sampling frequency, test methods, the criteria for interpreting results, corrective actions, and management changes to limit human exposure. Of the 25 institutions to which surveys were sent, 19 (76%) responded. Fourteen reported testing for fecal indicator bacteria in fish systems. The most commonly tested indicator species were total (86%) and fecal (79%) coliform bacteria, which were detected by means of the membrane filtration method (64%). Multiple types and sizes of systems were tested, and the guidelines for testing and corrective actions were highly variable. Only three institutions performed additional tests to confirm the identification of indicator organisms. The results from this study can be used to compare bacterial monitoring practices and protocols in fish systems, as an aid to discussions relating to the accuracy and reliability of test results, and to help implement appropriate management responses. Received August 23, 2015; accepted December 29, 2015.

  11. New method to monitor RF safety in MRI-guided interventions based on RF induced image artefacts.

    PubMed

    van den Bosch, Michiel R; Moerland, Marinus A; Lagendijk, Jan J W; Bartels, Lambertus W; van den Berg, Cornelis A T

    2010-02-01

    Serious tissue heating may occur at the tips of elongated metallic structures used in MRI-guided interventions, such as vascular guidewires, catheters, biopsy needles, and brachytherapy needles. This heating is due to resonating electromagnetic radiofrequency (RF) waves along the structure. Since it is hard to predict the exact length at which resonance occurs under in vivo conditions, there is a need for methods to monitor this resonance behavior. In this study, the authors propose a method based on the RF induced image artefacts and demonstrate its applicability in two phantom experiments. The authors developed an analytical model that describes the RF induced image artefacts as a function of the induced current in an elongated metallic structure placed parallel to the static magnetic field. It describes the total RF field as a sum of the RF fields produced by the transmit coil of the MR scanner and by the elongated metallic structure. Several spoiled gradient echo images with different nominal flip angle settings were acquired to map the B1+ field, which is a quantitative measure for the RF distortion around the structure. From this map, the current was extracted by fitting the analytical model. To investigate the sensitivity of our method we performed two phantom experiments with different setup parameters: One that mimics a brachytherapy needle insertion and one that resembles a guidewire intervention. In the first experiment, a short needle was placed centrally in the MR bore to ensure that the induced currents would be small. In the second experiment, a longer wire was placed in an off-center position to mimic a worst case scenario for the patient. In both experiments, a Luxtron (Santa Clara, CA) fiberoptic temperature sensor was positioned at the structure tip to record the temperature. In the first experiment, no significant temperature increases were measured, while the RF image artefacts and the induced currents in the needle increased with the applied insertion depth. The maximum induced current in the needle was 44 mA. Furthermore, a standing wave pattern became clearly visible for larger insertion depths. In the second experiment, significant temperature increases up to 2.4 degrees C in 1 min were recorded during the image acquisitions. The maximum current value was 1.4 A. In both experiments, a proper estimation of the current in the metallic structure could be made using our analytical model. The authors have developed a method to quantitatively determine the induced current in an elongated metallic structure from its RF distortion. This creates a powerful and sensitive method to investigate the resonant behavior of RF waves along elongated metallic structures used for MRI-guided interventions, for example, to monitor the RF safety or to inspect the influence of coating on the resonance length. Principally, it can be applied under in vivo conditions and for noncylindrical metallic structures such as hip implants by taking their geometry into account.

  12. Variability of slope current positioning from space: Application to the Northern Current in the North Western Mediterranean Sea

    NASA Astrophysics Data System (ADS)

    Bouffard, Jerome; Marmain, Julien; Bosse, Anthony; Petrenko, Anne; Forget, Philippe; Doglioli, Andrea; Testor, Pierre; Mortier, Laurent

    The space-time variability of slope currents plays a key role on the across-shore transport of natural and anthropogenic elements. It is therefore of critical importance to monitor the front positioning associated with these hydrodynamical features in a synoptic way, in particular along densely populated coasts such as the littoral zone of the Mediterranean Sea. Our paper proposes to address this issue by developing a new multi-satellite altimetric-based approach aiming at monitoring the long-term behaviour of the Northern Current, from 2002 to 2012. Our method is assessed by direct comparisons with observations from glider transects of the current, coastal HF radar and a moored current-meter. Despite important limitations due to the current altimetric sampling and a lower accuracy in the 50 km coastal band, we demonstrate the ability of our new method to characterize the variability of the front positioning from intra-seasonal to annual scales. We particularly focus the analysis on the Gulf of Lion, where the distance between the mean geostrophic flow and the coast allows a good detection of high frequency signals associated with slope current intrusions over the continental shelf. We show that such abrupt events generally occur in autumn and are forced by heterogeneous, strong and rapidly evolving south-easterly wind events. This work is based on an original exploitation of the existing along-track altimetry data and paves the way for new applications within the prospect of the next satellite generation whose technology is more suitable for coastal studies.

  13. Monitoring of Pre-Load on Rock Bolt Using Piezoceramic-Transducer Enabled Time Reversal Method.

    PubMed

    Huo, Linsheng; Wang, Bo; Chen, Dongdong; Song, Gangbing

    2017-10-27

    Rock bolts ensure structural stability for tunnels and many other underground structures. The pre-load on a rock bolt plays an important role in the structural reinforcement and it is vital to monitor the pre-load status of rock bolts. In this paper, a rock bolt pre-load monitoring method based on the piezoceramic enabled time reversal method is proposed. A lead zirconate titanate (PZT) patch transducer, which works as an actuator to generate stress waves, is bonded onto the anchor plate of the rock bolt. A smart washer, which is fabricated by sandwiching a PZT patch between two metal rings, is installed between the hex nut and the anchor plate along the rock bolt. The smart washer functions as a sensor to detect the stress wave. With the increase of the pre-load values on the rock bolt, the effective contact surface area between the smart washer and the anchor plate, benefiting the stress wave propagation crossing the contact surface. With the help of time reversal technique, experimental results reveal that the magnitude of focused signal clearly increases with the increase of the pre-load on a rock bolt before the saturation which happens beyond a relatively high value of the pre-load. The proposed method provides an innovative and real time means to monitor the pre-load level of a rock bolt. By employing this method, the pre-load degradation process on a rock bolt can be clearly monitored. Please note that, currently, the proposed method applies to only new rock bolts, on which it is possible to install the PZT smart washer.

  14. Real-time Implementation of the Waveloc Technique for Monitoring Earthquake Swarms

    NASA Astrophysics Data System (ADS)

    Maggi, A.; Langet, N.; Michelini, A.

    2013-12-01

    Monitoring regions with high swarm-type seismicity (e.g. volcanoes, certain tectonic regions) is a challenge for the traditional pick-associate-locate type algorithms that form the basis of most seismicity monitoring software. Over the past few years, new approaches that avoid the association phase by direct migration of some characteristic function of the recorded seismograms have started to be implemented, and have shown great promise (see related abstract on the Waveloc method applied to Piton de la Fournaise volcano). Implementing such methods in real-time is an essential step in proving their usefulness and robustness in swarm-monitoring situations. Here we describe the work in progress on adapting the Waveloc migration technique to real-time operation. The resulting software package, RT-Waveloc, is currently in the prototype stage, and we hope to have a version that can be distributed to the scientific community for beta-testing within a year. The development of RT-Waveloc is financed by the EU NERA project.

  15. Reporting vaccine-associated adverse events.

    PubMed Central

    Duclos, P.; Hockin, J.; Pless, R.; Lawlor, B.

    1997-01-01

    OBJECTIVE: To determine family physicians' awareness of the need to monitor and report vaccine-associated adverse events (VAAE) in Canada and to identify mechanisms that could facilitate reporting. DESIGN: Mailed survey. SETTING: Canadian family practices. PARTICIPANTS: Random sample of 747 family physicians. Overall response rate was 32% (226 of 717 eligible physicians). MAIN OUTCOME MEASURES: Access to education on VAAE; knowledge about VAAE monitoring systems, reporting criteria, and reporting forms; method of reporting VAAEs and reasons for not reporting them; and current experience with VAAEs. RESULTS: Of 226 respondents, 55% reported observing VAAEs, and 42% reported the event. Fewer than 50% were aware of a monitoring system for VAAE, and only 39% had had VAAE-related education during medical training. Only 28% knew the reporting criteria. Reporting was significantly associated with knowledge of VAAE monitoring systems and reporting criteria (P < 0.01). CONCLUSION: Physicians need more feedback and education on VAAE reporting and more information about the importance of reporting and about reporting criteria and methods. PMID:9303234

  16. LASER ABSORPTION SPECTROSCOPY METHODS FOR SUBSURFACE MONITORING OF CO2 IN WATER AND AIR PHASES AT SEQUESTRATION SITES

    NASA Astrophysics Data System (ADS)

    Wu, S.; Romanak, K.; Yang, C.

    2009-12-01

    We report the development of two methods for subsurface monitoring of CO2 in both air and water phases at sequestration sites. The first method is based on line-of-sight (LOS) tunable laser spectroscopy. Funded by DOE, we demonstrated the Phase Insensitive Two Tone Frquency Modulation spectroscopy (PITTFM). FM reduces low frequency noise in the beam path due to scintillations; while the PI design gives the ease of installation. We demonstrated measurement over 1 mile distance with an accuracy of 3ppm of CO2 in normal air. Built-in switches shoot the laser beam into multi-directions, thus forming a cellular monitoring network covering 10 km^2. The system cost is under $100K, and COTS telecom components guarantee the reliability in the field over decades. Software will log the data and translate the 2D CO2 profile. When coupled with other parameters, it will be able to locate the point and rate of leakages. Field tests at SECARB sequestration site are proposed. The system also monitors other green house gases (GHG), e.g. CH4, which is also needed where EOR is pursued along with CO2 sequestration. Figures 1 through 2 give the results of this method. The second method is based on the latest technology advances in quantum cascade lasers (QCLs). The current state of the art technology to measure Total/Dissolved Inorganic Carbon (TIC/DIC) in water is menometer. Menometer is both time consuming and costly, and could not be used underground, i.e. high pressure and temperature. We propose to use high brightness QC lasers to extend the current Mid-IR optical path from 30 microns to over 500microns, thus providing the possibility to measure CO2 dissoveled (Aqueous phase) with an accuracy of 0.2mg/Liter. Preliminary results will be presented.

  17. Novel minimally invasive multi-modality monitoring modalities in neurocritical care.

    PubMed

    Al-Mufti, Fawaz; Smith, Brendan; Lander, Megan; Damodara, Nitesh; Nuoman, Rolla; El-Ghanem, Mohammad; Kamal, Naveed; Al-Marsoummi, Sarmad; Alzubaidi, Basim; Nuoaman, Halla; Foreman, Brandon; Amuluru, Krishna; Gandhi, Chirag D

    2018-07-15

    Elevated intracranial pressure (ICP) following brain injury contributes to poor outcomes for patients, primarily by reducing the caliber of cerebral vasculature, and thereby reducing cerebral blood flow. Careful monitoring of ICP is critical in these patients in order to determine prognosis, implement treatment when ICP becomes elevated, and to judge responsiveness to treatment. Currently, the gold standard for monitoring is invasive pressure transducers, usually an intraventricular monitor, which presents significant risk of infection and hemorrhage. These risks made discovering non-invasive methods for monitoring ICP and cerebral perfusion a priority for researchers. Herein we sought to review recent publications on novel minimally invasive multi-modality monitoring techniques that provide surrogate data on ICP, cerebral oxygenation, metabolism and blood flow. While limitations in various forms preclude them from supplanting the use of invasive monitors, these modalities represent useful screening tools within our armamentarium that may be invaluable when the risks of invasive monitoring outweigh the associated benefits. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. A Novel Yeast Genomics Method for Identifying New Breast Cancer Susceptibility Genes

    DTIC Science & Technology

    2007-05-01

    find new candidate genes for breast cancer susceptibility in women and identifying these human genes can further improve monitoring and treatment...breast cancer susceptibility genes in humans that are currently unknown and not deducible from current methodologies. It is a fundamental...template to faithfully repair the broken strand. In human cancer it is loss of HR, rather than NHEJ, that is more important in increasing cancer

  19. Monitoring of Crew Activity with FAMOS

    NASA Astrophysics Data System (ADS)

    Wolf, L.; Cajochen, C.; Bromundt, V.

    2007-10-01

    The success of long duration space missions, such as manned missions to Mars, depends on high and sustained levels of vigilance and performance of astronauts and operators working in the technology rich environment of a spacecraft. Experiment 'Monitoring of Crew Activity with FAMOS' was set up to obtain operational experience with complimentary methods / technologies to assess the alertness / sleepiness status of selected AustroMars crewmembers on a daily basis. We applied a neurobehavioral test battery consisting of 1) Karolinska Sleepiness Scale KSS, 2) Karolinska Drowsiness Test KDT, 3) Psychomotor Vigilance Task PVT, combined with 4) left eye video recordings with an early prototype of the FAMOS Fatigue Monitoring System headset currently being developed by Sowoon Technologies (CH), and 5) Actiwatches that were worn continuously. A test battery required approximately 15 minutes and was repeated up to 4 times daily by 2 to 4 subjects. Here we present the data analysis of methods 1, 2, 3, and 5, while data analysis of method 4 is still in progress.

  20. NEXT GENERATION SEDIMENT TOXICITY TESTING VIA DNA MICROARRAYS - PHASE I

    EPA Science Inventory

    The current SBIR solicitation states that the EPA is seeking “better sampling, analysis, and monitoring technologies” to improve hazardous waste management.  Development of new methods for testing contaminated sediments is an area of particular concern because many industri...

  1. THE SIGNIFICANCE OF ENTERIC VIRUSES AND WATERBORNE ILLNESS

    EPA Science Inventory

    With growing concern over drinking water safety, considerable attention has been directed towards microbial pathogens in source waters, and the adequacy of current methods used to detect, monitor and treat for these pathogens. The focus has been on bacterial and protozoan pathog...

  2. DEVELOPMENT OF STANDARDIZED LARGE RIVER BIOASSESSMENT PROTOCOLS (LR-BP) FOR FISH ASSEMBLAGES

    EPA Science Inventory

    We conducted research comparing several methods currently in use for the bioassessment and monitoring of fish and benthic macroinvertebrate assemblages for large rivers. Fish data demonstrate that electrofishing 1000 m of shoreline is sufficient for bioassessments on boatable ri...

  3. A REVIEW OF APPLICATIONS OF LUMINESCENCE TO MONITORING OF CHEMICAL CONTAMINANTS IN THE ENVIRONMENT

    EPA Science Inventory

    The recent analytical literature on the application of luminescence techniques to the measurement of various classes of environmentally significant chemicals has been reviewed. Luminescent spectroscopy based methods are compared to other current techniques. Also, examples of rece...

  4. Active landslide monitoring using remote sensing data, GPS measurements and cameras on board UAV

    NASA Astrophysics Data System (ADS)

    Nikolakopoulos, Konstantinos G.; Kavoura, Katerina; Depountis, Nikolaos; Argyropoulos, Nikolaos; Koukouvelas, Ioannis; Sabatakakis, Nikolaos

    2015-10-01

    An active landslide can be monitored using many different methods: Classical geotechnical measurements like inclinometer, topographical survey measurements with total stations or GPS and photogrammetric techniques using airphotos or high resolution satellite images. As the cost of the aerial photo campaign and the acquisition of very high resolution satellite data is quite expensive the use of cameras on board UAV could be an identical solution. Small UAVs (Unmanned Aerial Vehicles) have started their development as expensive toys but they currently became a very valuable tool in remote sensing monitoring of small areas. The purpose of this work is to demonstrate a cheap but effective solution for an active landslide monitoring. We present the first experimental results of the synergistic use of UAV, GPS measurements and remote sensing data. A six-rotor aircraft with a total weight of 6 kg carrying two small cameras has been used. Very accurate digital airphotos, high accuracy DSM, DGPS measurements and the data captured from the UAV are combined and the results are presented in the current study.

  5. Understanding the behavior of Giardia and Cryptosporidium in an urban watershed: Explanation and application of techniques to collect and evaluate monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crockett, C.S.; Haas, C.N.

    1996-11-01

    Due to current proposed regulations requiring monitoring for protozoans and demonstration of adequate protozoan removal depending on source water concentrations detected, many utilities are considering or are engaged in protozoan monitoring activities within their watershed so that proper watershed management and treatment modifications can reduce their impact on drinking water safety and quality. However, due to the difficulties associated with the current analytical methods and sample collection many sampling efforts collect data that cannot be interpreted or lack the tools to interpret the information obtained. Therefore, it is necessary to determine how to develop an effective sampling program tailored tomore » a utility`s specific needs to provide interpretable data and develop tools for evaluating such data. The following case study describes the process in which a utility learned how to collect and interpret monitoring data for their specific needs and provides concepts and tools which other utilities can use to aid in their own macro and microwatershed management efforts.« less

  6. Disruption in the diabetic device care market

    PubMed Central

    Mohammed, Raihan

    2018-01-01

    As diabetes mellitus (DM) has approached pandemic proportions, the pressure for effective glycemic management is mounting. The starting point for managing and living well with DM involves early diagnosis and monitoring blood glucose levels. Therefore, self-monitoring of blood glucose (SMBG) can help patients maintain their blood glucose levels within the appropriate range. The general principle behind the current SMBG method involves a finger prick test to obtain a blood drop, which is applied onto a reagent strip and read by an automated device. Novel techniques are currently under evaluation to create the next generation of painless and accurate glucose monitoring for DM. We began by outlining how the emerging technology of the noninvasive glucose monitoring devices (NIGMDs) provides both economic and clinical benefits for health systems and patients. We further explored the engineering and techniques behind these upcoming devices. Finally, we evaluated how the NIGMDs disrupt the diabetic device care market and drive health care consumerism. We postulated that the NIGMDs play a pivotal role in the implementation of next generation of diabetes prevention strategies. PMID:29440935

  7. The effect of monitor raster latency on VEPs, ERPs and Brain-Computer Interface performance.

    PubMed

    Nagel, Sebastian; Dreher, Werner; Rosenstiel, Wolfgang; Spüler, Martin

    2018-02-01

    Visual neuroscience experiments and Brain-Computer Interface (BCI) control often require strict timings in a millisecond scale. As most experiments are performed using a personal computer (PC), the latencies that are introduced by the setup should be taken into account and be corrected. As a standard computer monitor uses a rastering to update each line of the image sequentially, this causes a monitor raster latency which depends on the position, on the monitor and the refresh rate. We technically measured the raster latencies of different monitors and present the effects on visual evoked potentials (VEPs) and event-related potentials (ERPs). Additionally we present a method for correcting the monitor raster latency and analyzed the performance difference of a code-modulated VEP BCI speller by correcting the latency. There are currently no other methods validating the effects of monitor raster latency on VEPs and ERPs. The timings of VEPs and ERPs are directly affected by the raster latency. Furthermore, correcting the raster latency resulted in a significant reduction of the target prediction error from 7.98% to 4.61% and also in a more reliable classification of targets by significantly increasing the distance between the most probable and the second most probable target by 18.23%. The monitor raster latency affects the timings of VEPs and ERPs, and correcting resulted in a significant error reduction of 42.23%. It is recommend to correct the raster latency for an increased BCI performance and methodical correctness. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Object-oriented Approach to High-level Network Monitoring and Management

    NASA Technical Reports Server (NTRS)

    Mukkamala, Ravi

    2000-01-01

    An absolute prerequisite for the management of large investigating methods to build high-level monitoring computer networks is the ability to measure their systems that are built on top of existing monitoring performance. Unless we monitor a system, we cannot tools. Due to the heterogeneous nature of the hope to manage and control its performance. In this underlying systems at NASA Langley Research Center, paper, we describe a network monitoring system that we use an object-oriented approach for the design, we are currently designing and implementing. Keeping, first, we use UML (Unified Modeling Language) to in mind the complexity of the task and the required model users' requirements. Second, we identify the flexibility for future changes, we use an object-oriented existing capabilities of the underlying monitoring design methodology. The system is built using the system. Third, we try to map the former with the latter. APIs offered by the HP OpenView system.

  9. Remote monitoring to Improve long-term prognosis in heart failure patients with implantable cardioverter-defibrillators.

    PubMed

    Ono, Maki; Varma, Niraj

    2017-05-01

    Strong evidence exists for the utility of remote monitoring in cardiac implantable electronic devices for early detection of arrhythmias and evaluation of system performance. The application of remote monitoring for the management of chronic disease such as heart failure has been an active area of research. Areas covered: This review aims to cover the latest evidence of remote monitoring of implantable cardiac defibrillators in terms of heart failure prognosis. This article also updates the current technology relating to the method and discusses key factors to be addressed in order to better use the approach. PubMed and internet searches were conducted to acquire most recent data and technology information. Expert commentary: Multiparameter monitoring with automatic transmission is useful for heart failure management. Improved adherence to remote monitoring and an optimal algorithm for transmitted alerts and their management are warranted in the management of heart failure.

  10. The Savannah River Site`s Groundwater Monitoring Program. Second quarter, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-10

    The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site`s (SRS) Groundwater Monitoring Program. During second quarter 1991 EPD/EMS conducted extensive sampling of monitoring wells. EPD/EMS established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead, they aid personnel in sample scheduling, interpretation of data, and trend identification. Beginning in 1991, the flagging criteria are based on EPA drinking water standards and method detection limits. A detailed explanation of the current flagging criteria is presented in the Flagging Criteria section of this document.more » Analytical results from second quarter 1991 are listed in this report.« less

  11. The Savannah River Site's Groundwater Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-10

    The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site's (SRS) Groundwater Monitoring Program. During second quarter 1991 EPD/EMS conducted extensive sampling of monitoring wells. EPD/EMS established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead, they aid personnel in sample scheduling, interpretation of data, and trend identification. Beginning in 1991, the flagging criteria are based on EPA drinking water standards and method detection limits. A detailed explanation of the current flagging criteria is presented in the Flagging Criteria section of this document.more » Analytical results from second quarter 1991 are listed in this report.« less

  12. The Savannah River Site's Groundwater Monitoring Program: Second quarter 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rogers, C.D.

    1992-10-07

    The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site's (SRS) Groundwater Monitoring Program. During second quarter 1992, EPD/EMS conducted extensive sampling of monitoring wells. EPD/EMS established two sets of criteria to assist in the management of sample results. The flagging criteria do not define contamination levels; instead, they aid personnel in sample scheduling, interpretation of data, and trend identification. Since 1991, the flagging criteria have been based on the federal Environmental Protection Agency (EPA) drinking water standards and on method detection limits. A detailed explanation of the current flagging criteria is presented in the Flagging Criteria sectionmore » of this document. Analytical results from second quarter 1992 are listed in this report.« less

  13. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals

    PubMed Central

    Manzano-Szalai, Krisztina; Pali-Schöll, Isabella; Krishnamurthy, Durga; Stremnitzer, Caroline; Flaschberger, Ingo; Jensen-Jarolim, Erika

    2016-01-01

    In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i) milk allergy, ii) peanut allergy and iii) egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour. PMID:26963393

  14. Rosetta Langmuir Probe Photoelectron Emission and Solar Ultraviolet Flux at Comet 67P

    NASA Astrophysics Data System (ADS)

    Johansson, F. L.; Odelstad, E.; Paulsson, J. J.; Harang, S. S.; Eriksson, A. I.; Mannel, T.; Vigren, E.; Edberg, N. J. T.; Miloch, W. J.; Simon Wedlund, C.; Thiemann, E.; Epavier, F.; Andersson, L.

    2017-12-01

    The Langmuir Probe instrument on Rosetta monitored the photoelectron emission current of the probes during the Rosetta mission at comet 67P/Churyumov-Gerasimenko, in essence acting as a photodiode monitoring the solar ultraviolet radiation at wavelengths below 250 nm. We have used three methods of extracting the photoelectron saturation current from the Langmuir probe measurements. The resulting dataset can be used as an index of the solar far and extreme ultraviolet at the Rosetta spacecraft position, including flares, in wavelengths that are important for photoionisation of the cometary neutral gas. Comparing the photoemission current to data measurements by MAVEN/EUVM and TIMED/SEE, we find good correlation when 67P was at large heliocentric distances early and late in the mission, but up to 50 percent decrease of the expected photoelectron current at perihelion. We discuss possible reasons for the photoemission decrease, including scattering and absorption by nanograins created by disintegration of cometary dust far away from the nucleus.

  15. Rosetta photoelectron emission and solar ultraviolet flux at comet 67P

    NASA Astrophysics Data System (ADS)

    Johansson, Fredrik L.; Odelstad, E.; Paulsson, J. J. P.; Harang, S. S.; Eriksson, A. I.; Mannel, T.; Vigren, E.; Edberg, N. J. T.; Miloch, W. J.; Simon Wedlund, C.; Thiemann, E.; Eparvier, F.; Andersson, L.

    2017-07-01

    The Langmuir Probe instrument on Rosetta monitored the photoelectron emission current of the probes during the Rosetta mission at comet 67P/Churyumov-Gerasimenko, in essence acting as a photodiode monitoring the solar ultraviolet radiation at wavelengths below 250 nm. We have used three methods of extracting the photoelectron saturation current from the Langmuir probe measurements. The resulting data set can be used as an index of the solar far and extreme ultraviolet at the Rosetta spacecraft position, including flares, in wavelengths which are important for photoionization of the cometary neutral gas. Comparing the photoemission current to data measurements by MAVEN/EUVM and TIMED/SEE, we find good correlation when 67P was at large heliocentric distances early and late in the mission, but up to 50 per cent decrease of the expected photoelectron current at perihelion. We discuss possible reasons for the photoemission decrease, including scattering and absorption by nanograins created by disintegration of cometary dust far away from the nucleus.

  16. A fast method for detecting Cryptosporidium parvum oocysts in real world samples

    NASA Astrophysics Data System (ADS)

    Stewart, Shona; McClelland, Lindy; Maier, John

    2005-04-01

    Contamination of drinking water with pathogenic microorganisms such as Cryptosporidium has become an increasing concern in recent years. Cryptosporidium oocysts are particularly problematic, as infections caused by this organism can be life threatening in immunocompromised patients. Current methods for monitoring and analyzing water are often laborious and require experts to conduct. In addition, many of the techniques require very specific reagents to be employed. These factors add considerable cost and time to the analytical process. Raman spectroscopy provides specific molecular information on samples, and offers advantages of speed, sensitivity and low cost over current methods of water monitoring. Raman spectroscopy is an optical method that has demonstrated the capability to identify and differentiate microorganisms at the species and strain levels. In addition, this technique has exhibited sensitivities down to the single organism detection limit. We have employed Raman spectroscopy and Raman Chemical Imaging, in conjunction with chemometric techniques, to detect small numbers of oocysts in the presence of interferents derived from real-world water samples. Our investigations have also indicated that Raman Chemical Imaging may provide chemical and physiological information about an oocyst sample which complements information provided by the traditional methods. This work provides evidence that Raman imaging is a useful technique for consideration in the water quality industry.

  17. High-Resolution Radioluminescence Microscopy for the Study of Prostate Tissue Slice Cell Metabolism and Monitoring of Treatment Response

    DTIC Science & Technology

    2015-09-01

    University, The Stanford CA 94305-2004 REPORT DATE : October 2015 TYPE OF REPORT: annual PREPARED FOR: U.S. Army Medical Research and Materiel... DATE (DD-MM-YYYY) October 2015 2. REPORT TYPE Annual Report 3. DATES COVERED (From - To) 30 Sep 2014 - 29 Sep 2015 4. TITLE AND SUBTITLE Monitoring...ABSTRACT Currently, prostate cancers are classified using the Gleason Grade system and immunohistochemistry. The shortcoming of this method is that

  18. Internal dosimetry monitoring equipment: Present and future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selby, J.; Carbaugh, E.H.; Lynch, T.P.

    1993-09-01

    We have attempted to characterize the current and future status of in vivo and in vitro measurement programs coupled with the associated radioanalytical methods and workplace monitoring. Developments in these areas must be carefully integrated by internal dosimetrists, radiochemists and field health physicists. Their goal should be uniform improvement rather than to focus on one specific area (e.g., dose modeling) to the neglect of other areas where the measurement capabilities are substantially less sophisticated and, therefore, the potential source of error is greatest.

  19. On-line Monitoring of Actinide Concentrations in Molten Salt Electrolyte

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtis W. Johnson; Mary Lou Dunzik-Gougar; Shelly X. Li

    2006-11-01

    Pyroprocessing, a treatment method for spent nuclear fuel (SNF), is currently being studied at the Idaho National Laboratory. The key operation of pyroprocessing which takes place in an electrorefiner is the electrochemical separation of actinides from other constituents in spent fuel. Efficient operation of the electrorefiner requires online monitoring of actinide concentrations in the molten salt electrolyte. Square-wave voltammetry (SWV) and normal pulse voltammetry (NPV) are being investigated to assess their applicability to the measurement of actinide concentrations in the electrorefiner.

  20. Restoration of the USS Monitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krop, David

    2010-03-02

    David Krop will discuss the ongoing efforts to conserve and exhibit the iconic Civil War ironclad USS Monitor at The Mariners' Museum. The presentation will cover past conservation accomplishments by conservators and NOAA specialists, current activities in the lab, and future plans to bring back to life one of the world's most famous warships. Learn about the complex methods and procedures used to treat the ship's revolving gun turret, steam engine, Dahlgren guns and carriages, as well as numerous small artifacts like personal items from the crew.

  1. The Continuous Monitoring of Desert Dust using an Infrared-based Dust Detection and Retrieval Method

    NASA Technical Reports Server (NTRS)

    Duda, David P.; Minnis, Patrick; Trepte, Qing; Sun-Mack, Sunny

    2006-01-01

    Airborne dust and sand are significant aerosol sources that can impact the atmospheric and surface radiation budgets. Because airborne dust affects visibility and air quality, it is desirable to monitor the location and concentrations of this aerosol for transportation and public health. Although aerosol retrievals have been derived for many years using visible and near-infrared reflectance measurements from satellites, the detection and quantification of dust from these channels is problematic over bright surfaces, or when dust concentrations are large. In addition, aerosol retrievals from polar orbiting satellites lack the ability to monitor the progression and sources of dust storms. As a complement to current aerosol dust retrieval algorithms, multi-spectral thermal infrared (8-12 micron) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Meteosat-8 Spinning Enhanced Visible and Infrared Imager (SEVIRI) are used in the development of a prototype dust detection method and dust property retrieval that can monitor the progress of Saharan dust fields continuously, both night and day. The dust detection method is incorporated into the processing of CERES (Clouds and the Earth s Radiant Energy System) aerosol retrievals to produce dust property retrievals. Both MODIS (from Terra and Aqua) and SEVERI data are used to develop the method.

  2. A new efficient method to monitor precocious puberty nationwide in France.

    PubMed

    Rigou, Annabel; Le Moal, Joëlle; Léger, Juliane; Le Tertre, Alain; Carel, Jean-Claude

    2018-02-01

    Clinical precocious puberty (PP) is a disease, reputed to be on the increase and suspected to be linked to endocrine disrupting chemicals (EDC) exposure. Population-based epidemiological data are lacking in France and scarce elsewhere. We accessed the feasibility of monitoring PP nationwide in France in this context, using a nationwide existing database, the French National Health Insurance Information System. Here, we present the method we used with a step-by-step approach to build and select the most suitable indicator. We built three indicators reflecting the incidence of idiopathic central precocious puberty (ICPP), the most frequent form of PP, and we compared these indicators according to their strengths and weaknesses with respect to surveillance purposes. Monitoring ICPP in France proved feasible using a Drug reimbursement indicator. Our method is cost efficient and highly relevant in public health surveillance. Our step-by-step approach proved helpful to achieve this project and could be proposed for assessing the feasibility of monitoring health outcomes of interest using existing data bases. What is known: • Precocious puberty (PP) is suspected to be related to EDC exposure and it is believed to be on the increase in France and in others countries. • Very few epidemiologic data on PP are currently available in the world at the national scale. What is new: • This is the first study describing a method to monitor the most frequent form of PP, idiopathic central PP (ICPP) nationwide in a cost-efficient way, using health insurance databases. • This cost-effective method will allow to estimate and monitor the incidence of ICPP in France and to analyze spatial variations at a very precise scale, which will be very useful to examine the role of environmental exposures, especially to EDCs.

  3. Monotonicity-based electrical impedance tomography for lung imaging

    NASA Astrophysics Data System (ADS)

    Zhou, Liangdong; Harrach, Bastian; Seo, Jin Keun

    2018-04-01

    This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e. the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung ventilation can be viewed as either semi-positive or semi-negative definite owing to monotonic conductivity changes within the lung regions. We used these monotonicity constraints to improve the quality of lung EIT imaging. We tested the proposed methods in numerical simulations, phantom experiments and human experiments.

  4. Overload protection system for power inverter

    NASA Technical Reports Server (NTRS)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  5. Detection of stator winding faults in induction motors using three-phase current monitoring.

    PubMed

    Sharifi, Rasool; Ebrahimi, Mohammad

    2011-01-01

    The objective of this paper is to propose a new method for the detection of inter-turn short circuits in the stator windings of induction motors. In the previous reported methods, the supply voltage unbalance was the major difficulty, and this was solved mostly based on the sequence component impedance or current which are difficult to implement. Some other methods essentially are included in the offline methods. The proposed method is based on the motor current signature analysis and utilizes three phase current spectra to overcome the mentioned problem. Simulation results indicate that under healthy conditions, the rotor slot harmonics have the same magnitude in three phase currents, while under even 1 turn (0.3%) short circuit condition they differ from each other. Although the magnitude of these harmonics depends on the level of unbalanced voltage, they have the same magnitude in three phases in these conditions. Experiments performed under various load, fault, and supply voltage conditions validate the simulation results and demonstrate the effectiveness of the proposed technique. It is shown that the detection of resistive slight short circuits, without sensitivity to supply voltage unbalance is possible. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Heart Rhythm Monitoring in the Constellation Lunar and Launch/Landing EVA Suit: Recommendations from an Expert Panel

    NASA Technical Reports Server (NTRS)

    Scheuring, Richard A.; Hamilton, D.; Jones, J. A.; Alexander, D.

    2008-01-01

    Currently there are several physiological monitoring requirements for Extravehicular Activity (EVA) in the Human-Systems Interface Requirements (HSIR) document, including continuous heart rhythm monitoring. However, it is not known whether heart rhythm monitoring in the lunar surface space suit is a necessary capability for lunar surface operations or in launch/landing suit the event of a cabin depressurization enroute to or from the moon. Methods: Current US astronaut corps demographic information was provided to an expert panel of cardiovascular medicine experts, including specialists in electrophysiology, exercise physiology, interventional cardiology and arrhythmia. This information included averages for male/female age, body mass index (BMI), blood pressure, cholesterol, inflammatory markers, echocardiogram, ranges for coronary artery calcium (CAC) scores for long duration astronauts, and ranges for heart rate (HR) and metabolic (MET) rates obtained during microgravity and lunar EVA. Results: The panel determined that no uncontrolled hazard was likely to occur in the suit during lunar surface or contingency microgravity ops that would require ECG monitoring in the highly screened US astronaut population. However having the capability for rhythm monitoring inside the vehicle (IVA) was considered critical to manage an astronaut in distress. Discussion: Heart rate (HR) monitoring alone allows effective monitoring of astronaut health and function. Consequently, electrocardiographic (ECG) monitoring capability as a clinical tool is not essential in the lunar or launch/landing space suit. However, the panel considered that rhythm monitoring could be useful in certain clinical situations, it was not considered required for safe operations. Also, lunar vehicles should be required to have ECG monitoring capability with a minimum of 5-lead ECG (derived 12- lead) for IVA medical assessments.

  7. Reduction of streamflow monitoring networks by a reference point approach

    NASA Astrophysics Data System (ADS)

    Cetinkaya, Cem P.; Harmancioglu, Nilgun B.

    2014-05-01

    Adoption of an integrated approach to water management strongly forces policy and decision-makers to focus on hydrometric monitoring systems as well. Existing hydrometric networks need to be assessed and revised against the requirements on water quantity data to support integrated management. One of the questions that a network assessment study should resolve is whether a current monitoring system can be consolidated in view of the increased expenditures in time, money and effort imposed on the monitoring activity. Within the last decade, governmental monitoring agencies in Turkey have foreseen an audit on all their basin networks in view of prevailing economic pressures. In particular, they question how they can decide whether monitoring should be continued or terminated at a particular site in a network. The presented study is initiated to address this question by examining the applicability of a method called “reference point approach” (RPA) for network assessment and reduction purposes. The main objective of the study is to develop an easily applicable and flexible network reduction methodology, focusing mainly on the assessment of the “performance” of existing streamflow monitoring networks in view of variable operational purposes. The methodology is applied to 13 hydrometric stations in the Gediz Basin, along the Aegean coast of Turkey. The results have shown that the simplicity of the method, in contrast to more complicated computational techniques, is an asset that facilitates the involvement of decision makers in application of the methodology for a more interactive assessment procedure between the monitoring agency and the network designer. The method permits ranking of hydrometric stations with regard to multiple objectives of monitoring and the desired attributes of the basin network. Another distinctive feature of the approach is that it also assists decision making in cases with limited data and metadata. These features of the RPA approach highlight its advantages over the existing network assessment and reduction methods.

  8. Mutual Inductance Problem for a System Consisting of a Current Sheet and a Thin Metal Plate

    NASA Technical Reports Server (NTRS)

    Fulton, J. P.; Wincheski, B.; Nath, S.; Namkung, M.

    1993-01-01

    Rapid inspection of aircraft structures for flaws is of vital importance to the commercial and defense aircraft industry. In particular, inspecting thin aluminum structures for flaws is the focus of a large scale R&D effort in the nondestructive evaluation (NDE) community. Traditional eddy current methods used today are effective, but require long inspection times. New electromagnetic techniques which monitor the normal component of the magnetic field above a sample due to a sheet of current as the excitation, seem to be promising. This paper is an attempt to understand and analyze the magnetic field distribution due to a current sheet above an aluminum test sample. A simple theoretical model, coupled with a two dimensional finite element model (FEM) and experimental data will be presented in the next few sections. A current sheet above a conducting sample generates eddy currents in the material, while a sensor above the current sheet or in between the two plates monitors the normal component of the magnetic field. A rivet or a surface flaw near a rivet in an aircraft aluminum skin will disturb the magnetic field, which is imaged by the sensor. Initial results showed a strong dependence of the flaw induced normal magnetic field strength on the thickness and conductivity of the current-sheet that could not be accounted for by skin depth attenuation alone. It was believed that the eddy current imaging method explained the dependence of the thickness and conductivity of the flaw induced normal magnetic field. Further investigation, suggested the complexity associated with the mutual inductance of the system needed to be studied. The next section gives an analytical model to better understand the phenomenon.

  9. Cleaning Hospital Room Surfaces to Prevent Health Care-Associated Infections: A Technical Brief.

    PubMed

    Han, Jennifer H; Sullivan, Nancy; Leas, Brian F; Pegues, David A; Kaczmarek, Janice L; Umscheid, Craig A

    2015-10-20

    The cleaning of hard surfaces in hospital rooms is critical for reducing health care-associated infections. This review describes the evidence examining current methods of cleaning, disinfecting, and monitoring cleanliness of patient rooms, as well as contextual factors that may affect implementation and effectiveness. Key informants were interviewed, and a systematic search for publications since 1990 was done with the use of several bibliographic and gray literature resources. Studies examining surface contamination, colonization, or infection with Clostridium difficile, methicillin-resistant Staphylococcus aureus, or vancomycin-resistant enterococci were included. Eighty studies were identified-76 primary studies and 4 systematic reviews. Forty-nine studies examined cleaning methods, 14 evaluated monitoring strategies, and 17 addressed challenges or facilitators to implementation. Only 5 studies were randomized, controlled trials, and surface contamination was the most commonly assessed outcome. Comparative effectiveness studies of disinfecting methods and monitoring strategies were uncommon. Future research should evaluate and compare newly emerging strategies, such as self-disinfecting coatings for disinfecting and adenosine triphosphate and ultraviolet/fluorescent surface markers for monitoring. Studies should also assess patient-centered outcomes, such as infection, when possible. Other challenges include identifying high-touch surfaces that confer the greatest risk for pathogen transmission; developing standard thresholds for defining cleanliness; and using methods to adjust for confounders, such as hand hygiene, when examining the effect of disinfecting methods.

  10. Cleaning Hospital Room Surfaces to Prevent Health Care–Associated Infections

    PubMed Central

    Han, Jennifer H.; Sullivan, Nancy; Leas, Brian F.; Pegues, David A.; Kaczmarek, Janice L.; Umscheid, Craig A.

    2015-01-01

    The cleaning of hard surfaces in hospital rooms is critical for reducing health care–associated infections. This review describes the evidence examining current methods of cleaning, disinfecting, and monitoring cleanliness of patient rooms, as well as contextual factors that may affect implementation and effectiveness. Key informants were interviewed, and a systematic search for publications since 1990 was done with the use of several bibliographic and gray literature resources. Studies examining surface contamination, colonization, or infection with Clostridium difficile, methicillin-resistant Staphylococcus aureus, or vancomycinresistant enterococci were included. Eighty studies were identified—76 primary studies and 4 systematic reviews. Forty-nine studies examined cleaning methods, 14 evaluated monitoring strategies, and 17 addressed challenges or facilitators to implementation. Only 5 studies were randomized, controlled trials, and surface contamination was the most commonly assessed outcome. Comparative effectiveness studies of disinfecting methods and monitoring strategies were uncommon. Future research should evaluate and compare newly emerging strategies, such as self-disinfecting coatings for disinfecting and adenosine triphosphate and ultraviolet/fluorescent surface markers for monitoring. Studies should also assess patient-centered outcomes, such as infection, when possible. Other challenges include identifying high-touch surfaces that confer the greatest risk for pathogen transmission; developing standard thresholds for defining cleanliness; and using methods to adjust for confounders, such as hand hygiene, when examining the effect of disinfecting methods. PMID:26258903

  11. ScatterBlogs2: real-time monitoring of microblog messages through user-guided filtering.

    PubMed

    Bosch, Harald; Thom, Dennis; Heimerl, Florian; Püttmann, Edwin; Koch, Steffen; Krüger, Robert; Wörner, Michael; Ertl, Thomas

    2013-12-01

    The number of microblog posts published daily has reached a level that hampers the effective retrieval of relevant messages, and the amount of information conveyed through services such as Twitter is still increasing. Analysts require new methods for monitoring their topic of interest, dealing with the data volume and its dynamic nature. It is of particular importance to provide situational awareness for decision making in time-critical tasks. Current tools for monitoring microblogs typically filter messages based on user-defined keyword queries and metadata restrictions. Used on their own, such methods can have drawbacks with respect to filter accuracy and adaptability to changes in trends and topic structure. We suggest ScatterBlogs2, a new approach to let analysts build task-tailored message filters in an interactive and visual manner based on recorded messages of well-understood previous events. These message filters include supervised classification and query creation backed by the statistical distribution of terms and their co-occurrences. The created filter methods can be orchestrated and adapted afterwards for interactive, visual real-time monitoring and analysis of microblog feeds. We demonstrate the feasibility of our approach for analyzing the Twitter stream in emergency management scenarios.

  12. Detection of Matrix Crack Density of CFRP using an Electrical Potential Change Method with Multiple Probes

    NASA Astrophysics Data System (ADS)

    Todoroki, Akira; Omagari, Kazuomi

    Carbon Fiber Reinforced Plastic (CFRP) laminates are adopted for fuel tank structures of next generation space rockets or automobiles. Matrix cracks may cause fuel leak or trigger fatigue damage. A monitoring system of the matrix crack density is required. The authors have developed an electrical resistance change method for the monitoring of delamination cracks in CFRP laminates. Reinforcement fibers are used as a self-sensing system. In the present study, the electric potential method is adopted for matrix crack density monitoring. Finite element analysis (FEA) was performed to investigate the possibility of monitoring matrix crack density using multiple electrodes mounted on a single surface of a specimen. The FEA reveals the matrix crack density increases electrical resistance for a target segment between electrodes. Experimental confirmation was also performed using cross-ply laminates. Eight electrodes were mounted on a single surface of a specimen using silver paste after polishing of the specimen surface with sandpaper. The two outermost electrodes applied electrical current, and the inner electrodes measured electric voltage changes. The slope of electrical resistance during reloading is revealed to be an appropriate index for the detection of matrix crack density.

  13. An "Off-the-Shelf" System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy.

    PubMed

    Neal, Robert E; Kavnoudias, Helen; Thomson, Kenneth R

    2015-06-01

    Irreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators. We describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator. Accuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues. This system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents-sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

  14. Estuarine monitoring programs in the Albemarle Sound study area, North Carolina

    USGS Publications Warehouse

    Moorman, Michelle; Kolb, Katharine R.; Supak, Stacy

    2014-01-01

    The purpose of this report is to identify major natural resource management issues for the region, provide information on current monitoring activities occurring within the Albemarle Sound study area, determine how the current monitoring network fits into the design of the NMN, and determine what additional monitoring data are needed to address these issues. In order to address these questions, a shapefile and data table were created to document monitoring and research programs in the Albemarle Sound study area with an emphasis on current monitoring programs within the region. This database was queried to determine monitoring gaps that existed in the Albemarle Sound by comparing current monitoring programs with the design indicated by the NMN. The report uses this information to provide recommendations on how monitoring could be improved in the Albemarle Sound study area.

  15. DEVELOPMENT OF STANDARDIZED LARGE RIVER BIOASSESSMENT PROTOCOLS (LR-BP) FOR BENTHIC MACROINVERTEBRATE ASSEMBLAGES

    EPA Science Inventory

    We conducted research comparing several methods currently in use for the bioassessment and monitoring of fish and benthic macroinvertebrate assemblages of large rivers. Fish data demonstrate that electrofishing 1000 m of shoreline is sufficient for bioassessments on boatable riv...

  16. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    PubMed

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the photometer-type dust monitors on the other hand showed little correlation. The Respicon also accurately measured the inhalable concentration, whereas the modified PDM underestimated it by ~27%. Photometer responses varied considerably with changing particle size, which resulted in appreciable errors in airborne inhalable dust concentration measurements. Similar trends were also observed during field trials. Despite having limitations, both the modified PDM and Respicon showed promise as real-time inhalable dust monitors.

  17. Phage phenomics: Physiological approaches to characterize novel viral proteins

    ScienceCinema

    Sanchez, Savannah E. [San Diego State Univ., San Diego, CA (United States); Cuevas, Daniel A. [San Diego State Univ., San Diego, CA (United States); Rostron, Jason E. [San Diego State Univ., San Diego, CA (United States); Liang, Tiffany Y. [San Diego State Univ., San Diego, CA (United States); Pivaroff, Cullen G. [San Diego State Univ., San Diego, CA (United States); Haynes, Matthew R. [San Diego State Univ., San Diego, CA (United States); Nulton, Jim [San Diego State Univ., San Diego, CA (United States); Felts, Ben [San Diego State Univ., San Diego, CA (United States); Bailey, Barbara A. [San Diego State Univ., San Diego, CA (United States); Salamon, Peter [San Diego State Univ., San Diego, CA (United States); Edwards, Robert A. [San Diego State Univ., San Diego, CA (United States); Argonne National Lab. (ANL), Argonne, IL (United States); Burgin, Alex B. [Broad Institute, Cambridge, MA (United States); Segall, Anca M. [San Diego State Univ., San Diego, CA (United States); Rohwer, Forest [San Diego State Univ., San Diego, CA (United States)

    2018-06-21

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysis by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Savannah E.; Cuevas, Daniel A.; Rostron, Jason E.

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysismore » by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.« less

  19. Emerging technologies for pediatric and adult trauma care.

    PubMed

    Moulton, Steven L; Haley-Andrews, Stephanie; Mulligan, Jane

    2010-06-01

    Current Emergency Medical Service protocols rely on provider-directed care for evaluation, management and triage of injured patients from the field to a trauma center. New methods to quickly diagnose, support and coordinate the movement of trauma patients from the field to the most appropriate trauma center are in development. These methods will enhance trauma care and promote trauma system development. Recent advances in machine learning, statistical methods, device integration and wireless communication are giving rise to new methods for vital sign data analysis and a new generation of transport monitors. These monitors will collect and synchronize exponentially growing amounts of vital sign data with electronic patient care information. The application of advanced statistical methods to these complex clinical data sets has the potential to reveal many important physiological relationships and treatment effects. Several emerging technologies are converging to yield a new generation of smart sensors and tightly integrated transport monitors. These technologies will assist prehospital providers in quickly identifying and triaging the most severely injured children and adults to the most appropriate trauma centers. They will enable the development of real-time clinical support systems of increasing complexity, able to provide timelier, more cost-effective, autonomous care.

  20. Frequency Based Volcanic Activity Detection through Remotely Sensed Data

    NASA Astrophysics Data System (ADS)

    Worden, A. K.; Dehn, J.; Webley, P. W.

    2015-12-01

    Satellite remote sensing has proved to offer a useful and relatively inexpensive method for monitoring large areas where field work is logistically unrealistic, and potentially dangerous. Current sensors are able to detect the majority of explosive volcanic activity; those that tend to effect and represent larger scale changes in the volcanic systems, eventually relating to ash producing periods of extended eruptive activity, and effusive activity. As new spaceborne sensors are developed, the ability to detect activity improves so that a system to gauge the frequency of volcanic activity can be used as a useful monitoring tool. Four volcanoes were chosen for development and testing of a method to monitor explosive activity: Stromboli (Italy); Shishaldin and Cleveland (Alaska, USA); and Karymsky (Kamchatka, Russia). Each volcano studied had similar but unique signatures of pre-cursory and eruptive activity. This study has shown that this monitoring tool could be applied to a wide range of volcanoes and still produce useful and robust data. Our method deals specifically with the detection of small scale explosive activity. The method described here could be useful in an operational setting, especially at remote volcanoes that have the potential to impact populations, infrastructure, and the aviation community. A number of important factors will affect the validity of application of this method. They are: (1) the availability of a continuous and continually populated dataset; (2) appropriate and reasonable sensor resolutions; (3) a recorded history of the volcano's previous activity; and, if available, (4) some ground-based monitoring system. We aim to develop the method further to be able to capture and evaluate the frequency of other volcanic processes such as lava flows, phreatomagmatic eruptions and dome growth and collapse. The work shown here has served to illustrate the capability of this method and monitoring tool for use at remote, un-instrumented volcanoes.

  1. Angular approach combined to mechanical model for tool breakage detection by eddy current sensors

    NASA Astrophysics Data System (ADS)

    Ritou, M.; Garnier, S.; Furet, B.; Hascoet, J. Y.

    2014-02-01

    The paper presents a new complete approach for Tool Condition Monitoring (TCM) in milling. The aim is the early detection of small damages so that catastrophic tool failures are prevented. A versatile in-process monitoring system is introduced for reliability concerns. The tool condition is determined by estimates of the radial eccentricity of the teeth. An adequate criterion is proposed combining mechanical model of milling and angular approach.Then, a new solution is proposed for the estimate of cutting force using eddy current sensors implemented close to spindle nose. Signals are analysed in the angular domain, notably by synchronous averaging technique. Phase shifts induced by changes of machining direction are compensated. Results are compared with cutting forces measured with a dynamometer table.The proposed method is implemented in an industrial case of pocket machining operation. One of the cutting edges has been slightly damaged during the machining, as shown by a direct measurement of the tool. A control chart is established with the estimates of cutter eccentricity obtained during the machining from the eddy current sensors signals. Efficiency and reliability of the method is demonstrated by a successful detection of the damage.

  2. Evaluation of Diesel Exhaust Continuous Monitors in Controlled Environmental Conditions

    PubMed Central

    Yu, Chang Ho; Patton, Allison P.; Zhang, Andrew; Fanac, Zhi-Hua (Tina); Weisel, Clifford P.; Lioy, Paul J.

    2015-01-01

    Diesel exhaust (DE) contains a variety of toxic air pollutants, including diesel particulate matter (DPM) and gaseous contaminants (e.g., carbon monoxide (CO)). DPM is dominated by fine (PM2.5) and ultrafine particles (UFP), and can be representatively determined by its thermal-optical refractory as elemental carbon (EC) or light-absorbing characteristics as black carbon (BC). The currently accepted reference method for sampling and analysis of occupational exposure to DPM is the National Institute for Occupational Safety and Health (NIOSH) Method 5040. However, this method cannot provide in-situ short-term measurements of DPM. Thus, real-time monitors are gaining attention to better examine DE exposures in occupational settings. However, real-time monitors are subject to changing environmental conditions. Field measurements have reported interferences in optical sensors and subsequent real-time readings, under conditions of high humidity and abrupt temperature changes. To begin dealing with these issues, we completed a controlled study to evaluate five real-time monitors: Airtec real-time DPM/EC Monitor, TSI SidePak Personal Aerosol Monitor AM510 (PM2.5), TSI Condensation Particle Counter 3007, microAeth AE51 BC Aethalometer, and Langan T15n CO Measurer. Tests were conducted under different temperatures (55, 70, and 80 °F), relative humidity (10, 40, and 80%), and DPM concentrations (50 and 200 µg/m3) in a controlled exposure facility. The 2-hour averaged EC measurements from the Airtec instrument showed relatively good agreement with NIOSH Method 5040 (R2=0.84; slope=1.17±0.06; N=27) and reported ~17% higher EC concentrations than the NIOSH reference method. Temperature, relative humidity, and DPM levels did not significantly affect relative differences in 2-hour averaged EC concentrations obtained by the Airtec instrument versus the NIOSH method (p<0.05). Multiple linear regression analyses, based on 1-min averaged data, suggested combined effects of up to 5% from relative humidity and temperature on real-time measurements. The overall deviations of these real-time monitors from the NIOSH method results were ≤20%. However, simultaneous monitoring of temperature and relative humidity is recommended in field investigations to understand and correct for environmental impacts on real-time monitoring data. PMID:25894766

  3. Real Time Monitoring System of Pollution Waste on Musi River Using Support Vector Machine (SVM) Method

    NASA Astrophysics Data System (ADS)

    Fachrurrozi, Muhammad; Saparudin; Erwin

    2017-04-01

    Real-time Monitoring and early detection system which measures the quality standard of waste in Musi River, Palembang, Indonesia is a system for determining air and water pollution level. This system was designed in order to create an integrated monitoring system and provide real time information that can be read. It is designed to measure acidity and water turbidity polluted by industrial waste, as well as to show and provide conditional data integrated in one system. This system consists of inputting and processing the data, and giving output based on processed data. Turbidity, substances, and pH sensor is used as a detector that produce analog electrical direct current voltage (DC). Early detection system works by determining the value of the ammonia threshold, acidity, and turbidity level of water in Musi River. The results is then presented based on the level group pollution by the Support Vector Machine classification method.

  4. Influence of atmospheric properties on detection of wood-warbler nocturnal flight calls

    NASA Astrophysics Data System (ADS)

    Horton, Kyle G.; Stepanian, Phillip M.; Wainwright, Charlotte E.; Tegeler, Amy K.

    2015-10-01

    Avian migration monitoring can take on many forms; however, monitoring active nocturnal migration of land birds is limited to a few techniques. Avian nocturnal flight calls are currently the only method for describing migrant composition at the species level. However, as this method develops, more information is needed to understand the sources of variation in call detection. Additionally, few studies examine how detection probabilities differ under varying atmospheric conditions. We use nocturnal flight call recordings from captive individuals to explore the dependence of flight call detection on atmospheric temperature and humidity. Height or distance from origin had the largest influence on call detection, while temperature and humidity also influenced detectability at higher altitudes. Because flight call detection varies with both atmospheric conditions and flight height, improved monitoring across time and space will require correction for these factors to generate standardized metrics of songbird migration.

  5. Method of and apparatus for determining deposition-point temperature

    DOEpatents

    Mansure, A.J.; Spates, J.J.; Martin, S.J.

    1998-10-27

    Acoustic-wave sensor apparatus and method are disclosed for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated. 5 figs.

  6. Method of and apparatus for determining deposition-point temperature

    DOEpatents

    Mansure, Arthur J.; Spates, James J.; Martin, Stephen J.

    1998-01-01

    Acoustic-wave sensor apparatus and method for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated.

  7. Resident Load Influence Analysis Method for Price Based on Non-intrusive Load Monitoring and Decomposition Data

    NASA Astrophysics Data System (ADS)

    Jiang, Wenqian; Zeng, Bo; Yang, Zhou; Li, Gang

    2018-01-01

    In the non-invasive load monitoring mode, the load decomposition can reflect the running state of each load, which will help the user reduce unnecessary energy costs. With the demand side management measures of time of using price, a resident load influence analysis method for time of using price (TOU) based on non-intrusive load monitoring data are proposed in the paper. Relying on the current signal of the resident load classification, the user equipment type, and different time series of self-elasticity and cross-elasticity of the situation could be obtained. Through the actual household load data test with the impact of TOU, part of the equipment will be transferred to the working hours, and users in the peak price of electricity has been reduced, and in the electricity at the time of the increase Electrical equipment, with a certain regularity.

  8. In-situ health monitoring of piezoelectric sensors using electromechanical impedance: A numerical perspective

    NASA Astrophysics Data System (ADS)

    Bilgunde, Prathamesh N.; Bond, Leonard J.

    2018-04-01

    Current work presents a numerical investigation to classify the in-situ health of the piezoelectric sensors deployed for structural health monitoring (SHM) of large civil, aircraft and automotive structures. The methodology proposed in this work attempts to model the in-homogeneities in the adhesive with which typically the sensor is bonded to the structure for SHM. It was found that weakening of the bond state causes reduction in the resonance frequency of the structure and eventually approaches the resonance characteristics of a piezoelectric material under traction-free boundary conditions. These changes in the resonance spectrum are further quantified using root mean square deviation-based damage index. Results demonstrate that the electromechanical impedance method can be used to monitor structural integrity of the sensor bonded to the host structure. This cost-effective method can potentially reduce misinterpretation of SHM data for critical infrastructures.

  9. Monitoring glacier albedo as a proxy to derive summer and annual surface mass balances from optical remote-sensing data

    NASA Astrophysics Data System (ADS)

    Davaze, Lucas; Rabatel, Antoine; Arnaud, Yves; Sirguey, Pascal; Six, Delphine; Letreguilly, Anne; Dumont, Marie

    2018-01-01

    Less than 0.25 % of the 250 000 glaciers inventoried in the Randolph Glacier Inventory (RGI V.5) are currently monitored with in situ measurements of surface mass balance. Increasing this archive is very challenging, especially using time-consuming methods based on in situ measurements, and complementary methods are required to quantify the surface mass balance of unmonitored glaciers. The current study relies on the so-called albedo method, based on the analysis of albedo maps retrieved from optical satellite imagery acquired since 2000 by the MODIS sensor, on board the TERRA satellite. Recent studies revealed substantial relationships between summer minimum glacier-wide surface albedo and annual surface mass balance, because this minimum surface albedo is directly related to the accumulation-area ratio and the equilibrium-line altitude. On the basis of 30 glaciers located in the French Alps where annual surface mass balance data are available, our study conducted on the period 2000-2015 confirms the robustness and reliability of the relationship between the summer minimum surface albedo and the annual surface mass balance. For the ablation season, the integrated summer surface albedo is significantly correlated with the summer surface mass balance of the six glaciers seasonally monitored. These results are promising to monitor both annual and summer glacier-wide surface mass balances of individual glaciers at a regional scale using optical satellite images. A sensitivity study on the computed cloud masks revealed a high confidence in the retrieved albedo maps, restricting the number of omission errors. Albedo retrieval artifacts have been detected for topographically incised glaciers, highlighting limitations in the shadow correction algorithm, although inter-annual comparisons are not affected by systematic errors.

  10. Emerging technologies for the non-invasive characterization of physical-mechanical properties of tablets.

    PubMed

    Dave, Vivek S; Shahin, Hend I; Youngren-Ortiz, Susanne R; Chougule, Mahavir B; Haware, Rahul V

    2017-10-30

    The density, porosity, breaking force, viscoelastic properties, and the presence or absence of any structural defects or irregularities are important physical-mechanical quality attributes of popular solid dosage forms like tablets. The irregularities associated with these attributes may influence the drug product functionality. Thus, an accurate and efficient characterization of these properties is critical for successful development and manufacturing of a robust tablets. These properties are mainly analyzed and monitored with traditional pharmacopeial and non-pharmacopeial methods. Such methods are associated with several challenges such as lack of spatial resolution, efficiency, or sample-sparing attributes. Recent advances in technology, design, instrumentation, and software have led to the emergence of newer techniques for non-invasive characterization of physical-mechanical properties of tablets. These techniques include near infrared spectroscopy, Raman spectroscopy, X-ray microtomography, nuclear magnetic resonance (NMR) imaging, terahertz pulsed imaging, laser-induced breakdown spectroscopy, and various acoustic- and thermal-based techniques. Such state-of-the-art techniques are currently applied at various stages of development and manufacturing of tablets at industrial scale. Each technique has specific advantages or challenges with respect to operational efficiency and cost, compared to traditional analytical methods. Currently, most of these techniques are used as secondary analytical tools to support the traditional methods in characterizing or monitoring tablet quality attributes. Therefore, further development in the instrumentation and software, and studies on the applications are necessary for their adoption in routine analysis and monitoring of tablet physical-mechanical properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A New Meteo-oceanographic and Environmental Monitoring Laboratory in Brazil

    NASA Astrophysics Data System (ADS)

    Fontes, Roberto F. C.; Dottori, Marcelo; Silveira, Ilson C. A.; Castro, Belmiro M.

    2013-04-01

    The newer oil provinces in the pre-salt regions off the Brazilian Coast have raised the necessity of the creation of monitoring and observational centers, regarding the best comprehension on the ocean and atmosphere dynamics. The relation between industry and university is a concept based on collaboration, and it is an innovative social experiment in Brazil. The sustainability of that collaboration depends on the balance of mutual interests on private business and public academic institutions. The entrepreneur needs continuous accesses to the new academic researches, and the greatest benefit, for the academy, are funding complementation and personnel qualification. We need to establish a thread of new challenges, some of them based on disruption of paradigms in the Brazilian academic culture, and removal of obstructive clauses from the entrepreneur. Questioning and methods revalidation, in the oceanic environment areas, also requires a collaborative and interdisciplinary effort, congregating the physical aspects along with others compartments of the environmental monitoring. We proposed the creation of a Meteo-oceanographic and Environmental Monitoring Laboratory - LAMMOA (Portuguese acronym), which will be installed in a new facility funded by PETROBRAS (the Brazilian leading oil company) and ruled by USP, UNESP and UNICAMP, the state public universities in Santos (São Paulo State, Brazil). The new facility will be a research center in oil and gas activities, named CENPEG-BS (Portuguese acronym for Research Center of Oil and Gas in the Bay of Santos). Several laboratories and groups will work together, in a highly collaborative environment and so, capable of quickly respond to sudden demands on offshore activities and logistic operations, as well as in contingency situations. LAMMOA will continuous monitor oceanic regions where the pre-salt activities of oil exploitation occur. It will monitor meteo-oceanographic parameters like winds, waves and currents, providing suitable data for offshore and transportation activities. For such, LAMMOA will operate a system of moored acoustic current meters and others environmental sensors, applying analytical and numerical methods for improving comprehension of the oceanic environment. Oceanographic gliders, satellite measurements and newer observational technics should replace expensive hydrographic surveys, and enhance the efforts on the knowledge of oceanographic processes as those that occur in the Brazil Current. We hope these actions create a new culture on continuous monitoring the ocean, along and offshore the 8,000-km Brazilian coast, including its continental shelf and coastal regions.

  12. Information Measures for Statistical Orbit Determination

    ERIC Educational Resources Information Center

    Mashiku, Alinda K.

    2013-01-01

    The current Situational Space Awareness (SSA) is faced with a huge task of tracking the increasing number of space objects. The tracking of space objects requires frequent and accurate monitoring for orbit maintenance and collision avoidance using methods for statistical orbit determination. Statistical orbit determination enables us to obtain…

  13. ON FARM SAMPLING FOR SALMONELLA: IMPACT OF METHOD AND DESIGN ON RESULTS

    USDA-ARS?s Scientific Manuscript database

    Current sampling for the National Antimicrobial Resistance Monitoring System (NARMS) is comprised primarily of receipt of Salmonella isolates from the USDA FSIS as part of their regulatory compliance testing. These isolates are received from all commodities and product classes. Isolates are charac...

  14. Water Chemistry of Ephemeral Streams

    Treesearch

    J.L. Michael; W.P. Fowler; H.L. Gibbs; J.B. Fischer

    1994-01-01

    Four individual, but related, studies are currently being conducted to determine the effects of clearcut and seed tree reproduction cutting methods on stream chemistry, sedimentation, and bedload movement by monitoring herbicide and nutrient movement in stemflow, overland flow, streamflow, and zonal subsurface flow. Sediment movement is being quantified for...

  15. Management Tools for Bus Maintenance: Current Practices and New Methods. Final Report.

    ERIC Educational Resources Information Center

    Foerster, James; And Others

    Management of bus fleet maintenance requires systematic recordkeeping, management reporting, and work scheduling procedures. Tools for controlling and monitoring routine maintenance activities are in common use. These include defect and fluid consumption reports, work order systems, historical maintenance records, and performance and cost…

  16. THE NEED FOR SPEED-RAPID METHODOLOGIES TO DETERMINE BATHING BEACH WATER QUALITY

    EPA Science Inventory

    Current methods for determining fecal contamination of recreational waters rely on the culture of bacterial indicators and require at least 24 hours to determine whether the water is unsafe for use. By the time monitoring results are available, exposures have already occurred. N...

  17. THE EMPACT BEACHES PROJECT - A STUDY OF THE PARAMETERS THAT AFFECT MICROBIOLOGICAL MONITORING

    EPA Science Inventory

    The current U. S. Environmental Protection Agency (EPA) water sample collection method for recreational water was suggested by the Federal Water Pollution Control Agency in 1968 as part of the fecal coliform guideline. Although improvements have been made in the indicator bacter...

  18. Real-time point-of-care measurement of impaired renal function in a rat acute injury model employing exogenous fluorescent tracer agents

    NASA Astrophysics Data System (ADS)

    Dorshow, Richard B.; Fitch, Richard M.; Galen, Karen P.; Wojdyla, Jolette K.; Poreddy, Amruta R.; Freskos, John N.; Rajagopalan, Raghavan; Shieh, Jeng-Jong; Demirjian, Sevag G.

    2013-02-01

    Renal function assessment is needed for the detection of acute kidney injury and chronic kidney disease. Glomerular filtration rate (GFR) is now widely accepted as the best indicator of renal function, and current clinical guidelines advocate its use in the staging of kidney disease. The optimum measure of GFR is by the use of exogenous tracer agents. However current clinically employed agents lack sensitivity or are cumbersome to use. An exogenous GFR fluorescent tracer agent, whose elimination rate could be monitored noninvasively through skin would provide a substantial improvement over currently available methods. We developed a series of novel aminopyrazine analogs for use as exogenous fluorescent GFR tracer agents that emit light in the visible region for monitoring GFR noninvasively over skin. In rats, these compounds are eliminated by the kidney with urine recovery greater than 90% of injected dose, are not broken down or metabolized in vivo, are not secreted by the renal tubules, and have clearance values similar to a GFR reference compound, iothalamate. In addition, biological half-life of these compounds measured in rats by noninvasive optical methods correlated with plasma derived methods. In this study, we show that this noninvasive methodology with our novel fluorescent tracer agents can detect impaired renal function. A 5/6th nephrectomy rat model is employed.

  19. GPS Monitor Station Upgrade Program at the Naval Research Laboratory

    NASA Technical Reports Server (NTRS)

    Galysh, Ivan J.; Craig, Dwin M.

    1996-01-01

    One of the measurements made by the Global Positioning System (GPS) monitor stations is to measure the continuous pseudo-range of all the passing GPS satellites. The pseudo-range contains GPS and monitor station clock errors as well as GPS satellite navigation errors. Currently the time at the GPS monitor station is obtained from the GPS constellation and has an inherent inaccuracy as a result. Improved timing accuracy at the GPS monitoring stations will improve GPS performance. The US Naval Research Laboratory (NRL) is developing hardware and software for the GPS monitor station upgrade program to improve the monitor station clock accuracy. This upgrade will allow a method independent of the GPS satellite constellation of measuring and correcting monitor station time to US Naval Observatory (USNO) time. THe hardware consists of a high performance atomic cesium frequency standard (CFS) and a computer which is used to ensemble the CFS with the two CFS's currently located at the monitor station by use of a dual-mixer system. The dual-mixer system achieves phase measurements between the high-performance CFS and the existing monitor station CFS's to within 400 femtoseconds. Time transfer between USNO and a given monitor station is achieved via a two way satellite time transfer modem. The computer at the monitor station disciplines the CFS based on a comparison of one pulse per second sent from the master site at USNO. The monitor station computer is also used to perform housekeeping functions, as well as recording the health status of all three CFS's. This information is sent to the USNO through the time transfer modem. Laboratory time synchronization results in the sub nanosecond range have been observed and the ability to maintain the monitor station CFS frequency to within 3.0 x 10 (sup minus 14) of the master site at USNO.

  20. The Power Plant Operating Data Based on Real-time Digital Filtration Technology

    NASA Astrophysics Data System (ADS)

    Zhao, Ning; Chen, Ya-mi; Wang, Hui-jie

    2018-03-01

    Real-time monitoring of the data of the thermal power plant was the basis of accurate analyzing thermal economy and accurate reconstruction of the operating state. Due to noise interference was inevitable; we need real-time monitoring data filtering to get accurate information of the units and equipment operating data of the thermal power plant. Real-time filtering algorithm couldn’t be used to correct the current data with future data. Compared with traditional filtering algorithm, there were a lot of constraints. First-order lag filtering method and weighted recursive average filtering method could be used for real-time filtering. This paper analyzes the characteristics of the two filtering methods and applications for real-time processing of the positive spin simulation data, and the thermal power plant operating data. The analysis was revealed that the weighted recursive average filtering method applied to the simulation and real-time plant data filtering achieved very good results.

  1. Remote sensing and avian influenza: A review of image processing methods for extracting key variables affecting avian influenza virus survival in water from Earth Observation satellites

    NASA Astrophysics Data System (ADS)

    Tran, Annelise; Goutard, Flavie; Chamaillé, Lise; Baghdadi, Nicolas; Lo Seen, Danny

    2010-02-01

    Recent studies have highlighted the potential role of water in the transmission of avian influenza (AI) viruses and the existence of often interacting variables that determine the survival rate of these viruses in water; the two main variables are temperature and salinity. Remote sensing has been used to map and monitor water bodies for several decades. In this paper, we review satellite image analysis methods used for water detection and characterization, focusing on the main variables that influence AI virus survival in water. Optical and radar imagery are useful for detecting water bodies at different spatial and temporal scales. Methods to monitor the temperature of large water surfaces are also available. Current methods for estimating other relevant water variables such as salinity, pH, turbidity and water depth are not presently considered to be effective.

  2. Measuring NO, NO2, CO2 and O3 with low-cost sensors

    NASA Astrophysics Data System (ADS)

    Müller, Michael; Graf, Peter; Hüglin, Christoph

    2017-04-01

    Inexpensive sensors measuring ambient gas concentrations can be integrated in sensor units forming dense sensor networks. The utilized sensors have to be sufficiently accurate as the value of such networks directly depends on the information they provide. Thus, thorough testing of sensors before bringing them into service and the application of effective strategies for performance monitoring and adjustments during service are key elements for operating the low-cost sensors that are currently available on the market. We integrated several types of low-cost sensors into sensor units (Alphasense NO2 B4/B42F/B43F, Alphasense NO B4, SensAir CO2 LP8, Aeroqual O3 SM50), run them in the field next to instruments of air quality monitoring stations and performed tests in the laboratory. The poster summarizes our findings regarding the achieved sensor accuracy, methods to improve sensor performance as well as strategies to monitor the current state of the sensor (drifts, sensitivity) within a sensor network.

  3. A portable monitor system for biology signal based on singlechip

    NASA Astrophysics Data System (ADS)

    Tu, Qiaoling; Guo, Jianhua; He, Li; Xu, Xia

    2005-12-01

    The objectives of the paper are to improve accuracy of the electrocardiogram and temperature signal, improve the system stability and the capability of dynamic response, and decrease power consumption and volume of the system. The basic method is making use of the inner resource of the singlechip, such as the exact constant-current source, hardware multiplier, ADC, etc. The model of singlechip is MSP430F449 of TI (Texas Instruments). A simple integral-coefficient band-rejection digital filter was designed for analyzing the electrocardiogram signal. The deviation of temperature coming from the degradation of battery voltage was compensated for. An automatic discharge access was designed in the circuit to improve the capability of dynamic response of circuit. The results indicate that the 50 Hz power frequency interfering and the baseline drift are filtered, the figure is clear, the accuracy of temperature is 0.03°C, and the consumption current is less than 1.3mA. The system can meet the requirement in ward monitor and surgery monitor.

  4. Application research on land use remote sensing dynamic monitoring: A case study of Anning district, Lanzhou

    NASA Astrophysics Data System (ADS)

    Zhu, Yunqiang; Zhu, Huazhong; Lu, Heli; Ni, Jianguang; Zhu, Shaoxia

    2005-10-01

    Remote sensing dynamic monitoring of land use can detect the change information of land use and update the current land use map, which is important for rational utilization and scientific management of land resources. This paper discusses the technological procedure of remote sensing dynamic monitoring of land use including the process of remote sensing images, the extraction of annual change information of land use, field survey, indoor post processing and accuracy assessment. Especially, we emphasize on comparative research on the choice of remote sensing rectifying models, image fusion algorithms and accuracy assessment methods. Taking Anning district in Lanzhou as an example, we extract the land use change information of the district during 2002-2003, access monitoring accuracy and analyze the reason of land use change.

  5. Exploring applications of GPR methodology and uses in determining floodplain function of restored streams in the Gulf Coastal Plain, Alabama

    NASA Astrophysics Data System (ADS)

    Eckes, S. W.; Shepherd, S. L.

    2017-12-01

    Accurately characterizing subsurface structure and function of remediated floodplains is indispensable in understanding the success of stream restoration projects. Although many of these projects are designed to address increased storm water runoff due to urbanization, long term monitoring and assessment are often limited in scope and methodology. Common monitoring practices include geomorphic surveys, stream discharge, and suspended sediment loads. These data are comprehensive for stream monitoring but they do not address floodplain function in terms of infiltration and through flow. Developing noninvasive methods for monitoring floodplain moisture transfer and distribution will aid in current and future stream restoration endeavors. Ground penetrating radar (GPR) has been successfully used in other physiographic regions for noninvasive and continuous monitoring of (1) natural geomorphic environments including subsurface structure and landform change and (2) soil and turf management to monitor subsurface moisture content. We are testing the viability of these existing methods to expand upon the broad capabilities of GPR. Determining suitability will be done in three parts using GPR to (1) find known buried objects of typical materials used in remediation at measured depths, (2) understand GPR functionality in varying soil moisture content thresholds on turf plots, and (3) model reference, remediated, and impacted floodplains in a case study in the D'Olive Creek watershed located in Baldwin County, Alabama. We hypothesize that these methods will allow us to characterize moisture transfer from precipitation and runoff to the floodplain which is a direct function of floodplain health. The need for a methodology to monitor floodplains is widespread and with increased resolution and mobility, expanding GPR applications may help streamline remediation and monitoring practices.

  6. Smart health monitoring systems: an overview of design and modeling.

    PubMed

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  7. Monitoring Endoplasmic Reticulum Calcium Homeostasis Using a Gaussia Luciferase SERCaMP.

    PubMed

    Henderson, Mark J; Wires, Emily S; Trychta, Kathleen A; Yan, Xiaokang; Harvey, Brandon K

    2015-09-06

    The endoplasmic reticulum (ER) contains the highest level of intracellular calcium, with concentrations approximately 5,000-fold greater than cytoplasmic levels. Tight control over ER calcium is imperative for protein folding, modification and trafficking. Perturbations to ER calcium can result in the activation of the unfolded protein response, a three-prong ER stress response mechanism, and contribute to pathogenesis in a variety of diseases. The ability to monitor ER calcium alterations during disease onset and progression is important in principle, yet challenging in practice. Currently available methods for monitoring ER calcium, such as calcium-dependent fluorescent dyes and proteins, have provided insight into ER calcium dynamics in cells, however these tools are not well suited for in vivo studies. Our lab has demonstrated that a modification to the carboxy-terminus of Gaussia luciferase confers secretion of the reporter in response to ER calcium depletion. The methods for using a luciferase based, secreted ER calcium monitoring protein (SERCaMP) for in vitro and in vivo applications are described herein. This video highlights hepatic injections, pharmacological manipulation of GLuc-SERCaMP, blood collection and processing, and assay parameters for longitudinal monitoring of ER calcium.

  8. Health Monitoring and Evaluation of Long-Span Bridges Based on Sensing and Data Analysis: A Survey

    PubMed Central

    Zhou, Jianting; Li, Xiaogang; Xia, Runchuan; Yang, Jun; Zhang, Hong

    2017-01-01

    Aimed at the health monitoring and evaluation of bridges based on sensing technology, the monitoring contents of different structural types of long-span bridges were defined. Then, the definition, classification, selection principle, and installation requirements of the sensors were summarized. The concept was proposed that new adaptable long-life sensors could be developed by new theories and new effects. The principle and methods to select controlled sections and optimize the layout design of measuring points were illustrated. The functional requirements were elaborated on about the acquisition, transmission, processing, and management of sensing information. Some advanced concepts about the method of bridge safety evaluation were demonstrated and technology bottlenecks in the current safety evaluation were also put forward. Ultimately, combined with engineering practices, an application was carried out. The results showed that new, intelligent, and reliable sensor technology would be one of the main future development directions in the long-span bridge health monitoring and evaluation field. Also, it was imperative to optimize the design of the health monitoring system and realize its standardization. Moreover, it is a heavy responsibility to explore new thoughts and new concepts regarding practical bridge safety and evaluation technology. PMID:28300785

  9. Developmental monitoring using caregiver reports in a resource-limited setting: the case of Kilifi, Kenya

    PubMed Central

    Abubakar, A; Holding, P; Van de Vijver, F; Bomu, G; Van Baar, A

    2010-01-01

    Aim: The main aim of the current study was to evaluate the reliability, validity and acceptability of developmental monitoring using caregiver reports among mothers in a rural African setting. Methods: A structured interview for parents of children aged 24 months and less was developed through both participant consultation and a review of literature. The reliability and validity of the schedule was evaluated through a 10-month monitoring programme of 95 children, aged 2–10 months. The acceptability of the process was evaluated by studying retention rates and by organizing focus group discussions with participating mothers. Results: The structured interview ‘Developmental Milestones Checklist’ consisted of 66 items covering three broad domains of child functioning: motor, language and personal–social development. The interview yielded scores of developmental achievements that showed high internal consistency and excellent test–retest reliability. The results were sensitive to maturational changes and nutritional deficiencies. In addition, acceptable retention rates of approximately 80% were found. Participating mothers reported that they found the procedures both acceptable and beneficial. Conclusion: Developmental monitoring using caregiver report is a viable method to identify and monitor at-risk children in Sub-Saharan Africa. PMID:20353499

  10. Is Technology-Mediated Parental Monitoring Related to Adolescent Substance Use?

    PubMed

    Rudi, Jessie; Dworkin, Jodi

    2018-01-03

    Prevention researchers have identified parental monitoring leading to parental knowledge to be a protective factor against adolescent substance use. In today's digital society, parental monitoring can occur using technology-mediated communication methods, such as text messaging, email, and social networking sites. The current study aimed to identify patterns, or clusters, of in-person and technology-mediated monitoring behaviors, and examine differences between the patterns (clusters) in adolescent substance use. Cross-sectional survey data were collected from 289 parents of adolescents using Facebook and Amazon Mechanical Turk (MTurk). Cluster analyses were computed to identify patterns of in-person and technology-mediated monitoring behaviors, and chi-square analyses were computed to examine differences in substance use between the identified clusters. Three monitoring clusters were identified: a moderate in-person and moderate technology-mediated monitoring cluster (moderate-moderate), a high in-person and high technology-mediated monitoring cluster (high-high), and a high in-person and low technology-mediated monitoring cluster (high-low). Higher frequency of technology-mediated parental monitoring was not associated with lower levels of substance use. Results show that higher levels of technology-mediated parental monitoring may not be associated with adolescent substance use.

  11. Freeze-drying process monitoring using a cold plasma ionization device.

    PubMed

    Mayeresse, Y; Veillon, R; Sibille, P H; Nomine, C

    2007-01-01

    A cold plasma ionization device has been designed to monitor freeze-drying processes in situ by monitoring lyophilization chamber moisture content. This plasma device, which consists of a probe that can be mounted directly on the lyophilization chamber, depends upon the ionization of nitrogen and water molecules using a radiofrequency generator and spectrometric signal collection. The study performed on this probe shows that it is steam sterilizable, simple to integrate, reproducible, and sensitive. The limitations include suitable positioning in the lyophilization chamber, calibration, and signal integration. Sensitivity was evaluated in relation to the quantity of vials and the probe positioning, and correlation with existing methods, such as microbalance, was established. These tests verified signal reproducibility through three freeze-drying cycles. Scaling-up studies demonstrated a similar product signature for the same product using pilot-scale and larger-scale equipment. On an industrial scale, the method efficiently monitored the freeze-drying cycle, but in a larger industrial freeze-dryer the signal was slightly modified. This was mainly due to the positioning of the plasma device, in relation to the vapor flow pathway, which is not necessarily homogeneous within the freeze-drying chamber. The plasma tool is a relevant method for monitoring freeze-drying processes and may in the future allow the verification of current thermodynamic freeze-drying models. This plasma technique may ultimately represent a process analytical technology (PAT) approach for the freeze-drying process.

  12. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.

  13. RAPIDLY-MEASURED INDICATORS OF RECREATIONAL WATER QUALITY ARE PREDICTIVE OF SWIMMING-ASSOCIATED GASTROINTESTINAL ILLNESS

    EPA Science Inventory

    Fecal indicator bacteria (FIB) are used to monitor recreational water quality worldwide. Current methods of measuring FIB require at least 24-hours for growth of bacterial colonies. We conducted studies at four Great Lake beaches to examine the relationship between novel and fas...

  14. Monitoring Ecological Impacts of Environmental Surface Waters using Cell-based Metabolomics

    EPA Science Inventory

    Optimized cell-based metabolomics has been used to study the impacts of contaminants in surface waters on human and fish metabolomes. This method has proven to be resource- and time-effective, as well as sustainable for long term and large scale studies. In the current study, cel...

  15. Understanding Information about Mortality among People with Intellectual and Developmental Disabilities in Canada

    ERIC Educational Resources Information Center

    Ouellette-Kuntz, Hélène; Shooshtari, Shahin; Balogh, Robert; Martens, Patricia

    2015-01-01

    Background: This paper reviews what is currently known about mortality among Canadians with intellectual and developmental disabilities and describes opportunities for ongoing monitoring. Methods: In-hospital mortality among adults with intellectual and developmental disabilities in Ontario was examined using hospital data. Mortality was compared…

  16. Chemical imaging of secondary cell wall development in cotton fibers using a mid-infrared focal-plane array detector

    USDA-ARS?s Scientific Manuscript database

    Market demands for cotton varieties with improved fiber properties also call for the development of fast, reliable analytical methods for monitoring fiber development and measuring their properties. Currently, cotton breeders rely on instrumentation that can require significant amounts of sample, w...

  17. Mapping and monitoring potato cropping systems in Maine: geospatial methods and land use assessments

    USDA-ARS?s Scientific Manuscript database

    Geospatial frameworks and GIS-based approaches were used to assess current cropping practices in potato production systems in Maine. Results from the geospatial integration of remotely-sensed cropland layers (2008-2011) and soil datasets for Maine revealed a four-year potato systems footprint estima...

  18. REAL TIME MONITORING OF PCDD/PCDF FOR TRANSIENT CHARACTERIZATION AND PROCESS CONTROL

    EPA Science Inventory

    Current sampling methods for PCDD/F emission compliance make use of a sample taken during steady state conditions which is assumed to be representative of facility performance. This is often less than satisfactory. The rapid variation of PCDDs, PCDF, and other co-pollutants due ...

  19. RAPID MEASUREMENT OF BACTERIAL FECAL INDICATORS IN SURFACE WATERS BY QUANTITATIVE POLYMERASE CHAIN REACTION (QPCR) ANALYSIS

    EPA Science Inventory

    Current methods for determining fecal contamination of recreational waters rely on the culture of bacterial indicators and require at least 24 hours to determine whether the water is unsafe for use. By the time monitoring results are available, exposures have already occurred. N...

  20. Differences in staining intensities affect reported occurrences and concentrations of Giardia spp. in surface drinking water sources

    EPA Science Inventory

    Aim USEPA Method 1623, or its equivalent, is currently used to monitor for protozoan contamination of surface drinking water sources worldwide. At least three approved staining kits used for detecting Cryptosporidium and Giardia are commercially available. This study focuses on ...

  1. RAPID PCR-BASED MONITORING OF INFECTIOUS ENTEROVIRUSES IN DRINKING WATER. (R824756)

    EPA Science Inventory

    Abstract

    Currently, the standard method for the detection of enteroviruses and hepatitis A virus in water involves cell culture assay which is expensive and time consuming. Direct RT-PCR offers a rapid and sensitive alternative to virus detection but sensitivity is oft...

  2. Current applications of GPR in forest research

    Treesearch

    John Butnor; Kurt Johnsen; Lisa Samuelson; Michele Pruyn

    2009-01-01

    Forests, both naturally regenerated stands and plantations are complex, long-lived systems, which can be difficult to assess and monitor over time. This is especially true of belowground biomass and internal features of trees which are inaccessible except by destructive sampling. Traditional methods are expensive, destructive, time-consuming, usually yield a small...

  3. Simultaneous analysis of fourteen endogenous steroid hormones by liquid chromatography tandem mass spectrometry with atmospheric pressure photoionization

    EPA Science Inventory

    Product Description: To understand how some chemicals affect the endocrine system, controlled lab experiments often monitor how chemicals impact natural steroid hormones in fish. Current methods can target only one or two hormones in a single sample, limiting the information that...

  4. Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation.

    PubMed

    Kollias, Anastasios; Stergiou, George S

    2014-01-01

    1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives. © 2013 Wiley Publishing Asia Pty Ltd.

  5. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    PubMed Central

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  6. Reduction of ground noise in the transmitter crowbar instrumentation system by the use of baluns and other noise rejection methods

    NASA Technical Reports Server (NTRS)

    Daeges, J.; Bhanji, A.

    1987-01-01

    Electrical noise interference in the transmitter crowbar monitoring instrumentation system creates false sensing of crowbar faults during a crowbar firing. One predominant source of noise interference is the conduction of currents in the instrumentation cable shields. Since these circulating ground noise currents produce noise that is similar to the crowbar fault sensing signals, such noise interference reduces the ability to determine true crowbar faults.

  7. eMethylsorb: electrochemical quantification of DNA methylation at CpG resolution using DNA-gold affinity interactions.

    PubMed

    Sina, Abu Ali Ibn; Howell, Sidney; Carrascosa, Laura G; Rauf, Sakandar; Shiddiky, Muhammad J A; Trau, Matt

    2014-11-07

    We report a simple electrochemical method referred to as "eMethylsorb" for the detection of DNA methylation. The method relies on the base dependent affinity interaction of DNA with gold. The methylation status of DNA is quantified by monitoring the electrochemical current as a function of the relative adsorption level of bisulphite treated DNA samples onto a bare gold electrode. This method can successfully distinguish methylated and unmethylated epigenotypes at single CpG resolution.

  8. The deep-tow marine controlled-source electromagnetic transmitter system for gas hydrate exploration

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Deng, Ming; Wu, Zhongliang; Luo, Xianhu; Jing, Jianen; Chen, Kai

    2017-02-01

    The Marine Controlled-Source Electromagnetic (MCSEM) method has been recognized as an important and effective tool to detect electrically resistive structures, such as oil, gas, and gas hydrate. The MCSEM performance is strongly influenced by the transmitter system design. We have developed a deep-tow MCSEM transmitter system. In this paper, some new technical details will be present. A 10,000 m optical-electrical composite cable is used to support high power transmission and fast data transfer; a new clock unit is designed to keep the synchronization between transmitter and receivers, and mark the time stamp into the transmission current full waveform; a data link is established to monitor the real-time altitude of the tail unit; an online insulation measuring instrument is adopted to monitor current leakage from high voltage transformer; a neutrally buoyant dipole antenna of copper cable and flexible electrodes are created to transmit the large power current into seawater; a new design method for the transmitter, which is called "real-time control technology of hardware parallelism", is described to achieve inverting and recording high-power current waveform, controlling functions, and collecting auxiliary information. We use a gas hydrate exploration test to verify the performance of the transmitter system, focusing on more technical details, rather than applications. The test shows that the transmitter can be used for gas hydrate exploration as an effective source.

  9. The U.S. Forest Service's analysis of cumulative effects to wildlife: A study of legal standards, current practice, and ongoing challenges on a National Forest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schultz, Courtney A., E-mail: courtney.schultz@colostate.edu

    Cumulative effects analysis (CEA) allows natural resource managers to understand the status of resources in historical context, learn from past management actions, and adapt future activities accordingly. U.S. federal agencies are required to complete CEA as part of environmental impact assessment under the National Environmental Policy Act (NEPA). Past research on CEA as part of NEPA has identified significant deficiencies in CEA practice, suggested methodologies for handling difficult aspects of CEA, and analyzed the rise in litigation over CEA in U.S. courts. This article provides a review of the literature and legal standards related to CEA as it is donemore » under NEPA and then examines current practice on a U.S. National Forest, utilizing qualitative methods in order to provide a detailed understanding of current approaches to CEA. Research objectives were to understand current practice, investigate ongoing challenges, and identify impediments to improvement. Methods included a systematic review of a set of NEPA documents and semi-structured interviews with practitioners, scientists, and members of the public. Findings indicate that the primary challenges associated with CEA include: issues of both geographic and temporal scale of analysis, confusion over the purpose of the requirement, the lack of monitoring data, and problems coordinating and disseminating data. Improved monitoring strategies and programmatic analyses could support improved CEA practice.« less

  10. Control of a rotary pulsatile cardiac assist pump driven by an electric motor without a pressure sensor to avoid collapse of the pump inlet.

    PubMed

    Trinkl, J; Havlik, P; Mesana, T; Mitsui, N; Morita, S; Demunck, J L; Tourres, J L; Monties, J R

    1993-01-01

    Our ventricular assist device uses a valveless volumetric pump operating on the Maillard-Wankel rotary principle. It is driven by an electric motor and provides a semi pulsatile flow. At each cycle, blood is actively aspirated into the device, and overpumping results in collapse at the pump inlet. To prevent overpumping, it is necessary to ensure that pump intake does not exceed venous return. Poor long-term reliability rules out the use of current implantable pressure sensors for this purpose. To resolve this problem, we have developed a method of control based on monitoring of the intensity of electric current consumed by the motor. The method consists of real time monitoring of current intensity at the beginning of each pump cycle. A sudden change in intensity indicates underfilling, and motor speed is reduced to prevent collapse. The current consumed by the motor also depends on the afterload, but the form of the signal remains the same when afterload changes. After demonstrating the feasibility of this technique in a simulator, we are now testing it in animals. We were able to detect and prevent collapse due to overpumping by the cardiac assist device. This system also enables us to know the maximum possible assistance and to thus adapt assistance to the user.

  11. Application of GIS technologies to monitor secondary radioactive contamination in the Delegen mountain massif

    NASA Astrophysics Data System (ADS)

    Alipbeki, O.; Kabzhanova, G.; Kurmanova, G.; Alipbekova, Ch.

    2016-06-01

    The territory of the Degelen mountain massif is located within territory of the former Semipalatinsk nuclear test site and it is an area of ecological disaster. Currently there is a process of secondary radioactive contamination that is caused by geodynamic processes activated at the Degelen array, violation of underground hydrological cycles and as a consequence, water seepage into the tunnels. One of the methods of monitoring of geodynamic processes is the modern technology of geographic information systems (GIS), methods of satellite radar interferometry and high accuracy satellite navigation system in conjunction with radioecological methods. This paper discusses on the creation of a GIS-project for the Degelen array, facilitated by quality geospatial analysis of the situation and simulation of the phenomena, in order to maximize an objective assessment of the radiation situation in this protected area.

  12. How to Monitor the Breathing of Laboratory Rodents: A Review of the Current Methods.

    PubMed

    Grimaud, Julien; Murthy, Venkatesh N

    2018-05-23

    Accurately measuring respiration in laboratory rodents is essential for many fields of research, including olfactory neuroscience, social behavior, learning and memory, and respiratory physiology. However, choosing the right technique to monitor respiration can be tricky, given the many criteria to take into account: reliability, precision, and invasiveness, to name a few. This review aims to assist experimenters in choosing the technique that will best fit their needs, by surveying the available tools, discussing their strengths and weaknesses, and offering suggestions for future improvements.

  13. 3D Electrical Resistivity Tomography and Mise-à-la-Masse Method as Tools for the Characterization of Vine Roots

    NASA Astrophysics Data System (ADS)

    Boaga, J.; Mary, B.; Peruzzo, L.; Schmutz, M.; Wu, Y.; Hubbard, S. S.; Cassiani, G.

    2017-12-01

    The interest on non-invasive geophysical monitoring of soil properties and root architecture is rapidly growing. Despite this, few case studies exist concerning vineyards, which are economically one of the leading sectors of agriculture. In this study, we integrate different geophysical methods in order to gain a better imaging of the vine root system, with the aim of quantifying root development, a key factor to understand roots-soil interaction and water balance. Our test site is a vineyard located in Bordeaux (France), where we adopted the Mise-a-la-Masse method (MALM) and micro-scale electrical resistivity tomography (ERT) on the same 3D electrode configuration. While ERT is a well-established technique to image changes in soil moisture content by root activity, MALM is a relatively new approach in this field of research. The idea is to inject current directly in the plant trunk and verify the resulting voltage distribution in the soil, as an effect of current distribution through the root system. In order to distinguish the root effect from other phenomena linked to the soil heterogeneities, we conducted and compared MALM measurements acquired through injecting current into the stem and into the soil near the stem. Moreover, the MALM data measured in the field were compared with numerical simulations to improve the confidence in the interpretation. Differences obtained between the stem and soil injection clearly validated the assumption that the whole root system is acting as a current pathway, thus highlighting the locations at depth where current is entering the soil from the fine roots. The simulation results indicated that the best fit is obtained through considering distributed sources with depth, reflecting a probable root zone area. The root location and volume estimated using this procedure are in agreement with vineyard experimental evidence. This work suggests the promising application of electrical methods to locate and monitor root systems. Further work is necessary to effectively integrate the geophysical and plant physiology information.

  14. Using multi-scale entropy and principal component analysis to monitor gears degradation via the motor current signature analysis

    NASA Astrophysics Data System (ADS)

    Aouabdi, Salim; Taibi, Mahmoud; Bouras, Slimane; Boutasseta, Nadir

    2017-06-01

    This paper describes an approach for identifying localized gear tooth defects, such as pitting, using phase currents measured from an induction machine driving the gearbox. A new tool of anomaly detection based on multi-scale entropy (MSE) algorithm SampEn which allows correlations in signals to be identified over multiple time scales. The motor current signature analysis (MCSA) in conjunction with principal component analysis (PCA) and the comparison of observed values with those predicted from a model built using nominally healthy data. The Simulation results show that the proposed method is able to detect gear tooth pitting in current signals.

  15. A Consensus-Based Interpretation of the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure Trial.

    PubMed

    Chesnut, Randall M; Bleck, Thomas P; Citerio, Giuseppe; Classen, Jan; Cooper, D James; Coplin, William M; Diringer, Michael N; Grände, Per-Olof; Hemphill, J Claude; Hutchinson, Peter J; Le Roux, Peter; Mayer, Stephan A; Menon, David K; Myburgh, John A; Okonkwo, David O; Robertson, Claudia S; Sahuquillo, Juan; Stocchetti, Nino; Sung, Gene; Temkin, Nancy; Vespa, Paul M; Videtta, Walter; Yonas, Howard

    2015-11-15

    Widely-varying published and presented analyses of the Benchmark Evidence From South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial of intracranial pressure (ICP) monitoring have suggested denying trial generalizability, questioning the need for ICP monitoring in severe traumatic brain injury (sTBI), re-assessing current clinical approaches to monitored ICP, and initiating a general ICP-monitoring moratorium. In response to this dissonance, 23 clinically-active, international opinion leaders in acute-care sTBI management met to draft a consensus statement to interpret this study. A Delphi method-based approach employed iterative pre-meeting polling to codify the group's general opinions, followed by an in-person meeting wherein individual statements were refined. Statements required an agreement threshold of more than 70% by blinded voting for approval. Seven precisely-worded statements resulted, with agreement levels of 83% to 100%. These statements, which should be read in toto to properly reflect the group's consensus positions, conclude that the BEST TRIP trial: 1) studied protocols, not ICP-monitoring per se; 2) applies only to those protocols and specific study groups and should not be generalized to other treatment approaches or patient groups; 3) strongly calls for further research on ICP interpretation and use; 4) should be applied cautiously to regions with much different treatment milieu; 5) did not investigate the utility of treating monitored ICP in the specific patient group with established intracranial hypertension; 6) should not change the practice of those currently monitoring ICP; and 7) provided a protocol, used in non-monitored study patients, that should be considered when treating without ICP monitoring. Consideration of these statements can clarify study interpretation.

  16. Monitoring nutrition and glucose in acute brain injury.

    PubMed

    Badjatia, Neeraj; Vespa, Paul

    2014-12-01

    The metabolic response to injury is well described; however, very little is understood about optimal markers to measure this response. This summary will address the current evidence about monitoring nutritional status including blood glucose after acute brain injury (ABI). An electronic literature search was conducted for English language articles describing the testing, utility, and optimal methods to measure nutritional status and blood glucose levels in the neurocritical care population. A total of 45 articles were included in this review. Providing adequate and timely nutritional support can help improve outcome after ABI. However, the optimal content and total nutrition requirements remain unclear. In addition, how best to monitor the nutritional status in ABI is still being elucidated, and at present, there is no validated optimal method to monitor the global response to nutritional support on a day-to-day basis in ABI patients. Nitrogen balance may be monitored to assess the adequacy of caloric intake as it relates to protein energy metabolism, but indirect calorimetry, anthropometric measurement, or serum biomarker requires further validation. The adverse effects of hyperglycemia in ABI are well described, and data indicate that blood glucose should be carefully controlled in critically ill patients. However, the optimal frequency or duration for blood glucose monitoring after ABI remains poorly defined. There are significant knowledge gaps about monitoring nutritional status and response to nutritional interventions in ABI; these need to be addressed and hence few recommendations can be made. The optimal frequency and duration of blood glucose monitoring need further study.

  17. Sparse filtering with the generalized lp/lq norm and its applications to the condition monitoring of rotating machinery

    NASA Astrophysics Data System (ADS)

    Jia, Xiaodong; Zhao, Ming; Di, Yuan; Li, Pin; Lee, Jay

    2018-03-01

    Sparsity is becoming a more and more important topic in the area of machine learning and signal processing recently. One big family of sparse measures in current literature is the generalized lp /lq norm, which is scale invariant and is widely regarded as normalized lp norm. However, the characteristics of the generalized lp /lq norm are still less discussed and its application to the condition monitoring of rotating devices has been still unexplored. In this study, we firstly discuss the characteristics of the generalized lp /lq norm for sparse optimization and then propose a method of sparse filtering with the generalized lp /lq norm for the purpose of impulsive signature enhancement. Further driven by the trend of industrial big data and the need of reducing maintenance cost for industrial equipment, the proposed sparse filter is customized for vibration signal processing and also implemented on bearing and gearbox for the purpose of condition monitoring. Based on the results from the industrial implementations in this paper, the proposed method has been found to be a promising tool for impulsive feature enhancement, and the superiority of the proposed method over previous methods is also demonstrated.

  18. Upcoming Methods and Specifications of Continuous Intraocular Pressure Monitoring Systems for Glaucoma

    PubMed Central

    Molaei, Amir; Karamzadeh, Vahid; Safi, Sare; Esfandiari, Hamed; Dargahi, Javad; Khosravi, Mohammad Azam

    2018-01-01

    Glaucoma is the leading cause of irreversible blindness and vision loss in the world. Although intraocular pressure (IOP) is no longer considered the only risk factor for glaucoma, it is still the most important one. In most cases, high IOP is secondary to trabecular meshwork dysfunction. High IOP leads to compaction of the lamina cribrosa and subsequent damage to retinal ganglion cell axons. Damage to the optic nerve head is evident on funduscopy as posterior bowing of the lamina cribrosa and increased cupping. Currently, the only documented method to slow or halt the progression of this disease is to decrease the IOP; hence, accurate IOP measurement is crucial not only for diagnosis, but also for the management. Due to the dynamic nature and fluctuation of the IOP, a single clinical measurement is not a reliable indicator of diurnal IOP; it requires 24-hour monitoring methods. Technological advances in microelectromechanical systems and microfluidics provide a promising solution for the effective measurement of IOP. This paper provides a broad overview of the upcoming technologies to be used for continuous IOP monitoring. PMID:29403593

  19. Evaluation of Content-Matched Range Monitoring Queries over Moving Objects in Mobile Computing Environments.

    PubMed

    Jung, HaRim; Song, MoonBae; Youn, Hee Yong; Kim, Ung Mo

    2015-09-18

    A content-matched (CM) rangemonitoring query overmoving objects continually retrieves the moving objects (i) whose non-spatial attribute values are matched to given non-spatial query values; and (ii) that are currently located within a given spatial query range. In this paper, we propose a new query indexing structure, called the group-aware query region tree (GQR-tree) for efficient evaluation of CMrange monitoring queries. The primary role of the GQR-tree is to help the server leverage the computational capabilities of moving objects in order to improve the system performance in terms of the wireless communication cost and server workload. Through a series of comprehensive simulations, we verify the superiority of the GQR-tree method over the existing methods.

  20. The technique of entropy optimization in motor current signature analysis and its application in the fault diagnosis of gear transmission

    NASA Astrophysics Data System (ADS)

    Chen, Xiaoguang; Liang, Lin; Liu, Fei; Xu, Guanghua; Luo, Ailing; Zhang, Sicong

    2012-05-01

    Nowadays, Motor Current Signature Analysis (MCSA) is widely used in the fault diagnosis and condition monitoring of machine tools. However, although the current signal has lower SNR (Signal Noise Ratio), it is difficult to identify the feature frequencies of machine tools from complex current spectrum that the feature frequencies are often dense and overlapping by traditional signal processing method such as FFT transformation. With the study in the Motor Current Signature Analysis (MCSA), it is found that the entropy is of importance for frequency identification, which is associated with the probability distribution of any random variable. Therefore, it plays an important role in the signal processing. In order to solve the problem that the feature frequencies are difficult to be identified, an entropy optimization technique based on motor current signal is presented in this paper for extracting the typical feature frequencies of machine tools which can effectively suppress the disturbances. Some simulated current signals were made by MATLAB, and a current signal was obtained from a complex gearbox of an iron works made in Luxembourg. In diagnosis the MCSA is combined with entropy optimization. Both simulated and experimental results show that this technique is efficient, accurate and reliable enough to extract the feature frequencies of current signal, which provides a new strategy for the fault diagnosis and the condition monitoring of machine tools.

  1. Unattended Dual Current Monitor (UDCM) FY17 Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newell, Matthew R.

    The UDCM is a low current measurement device designed to record pico-amp to micro-amp currents from radiation detectors. The UDCM is the planned replacement for the IAEA’s obsolete MiniGRAND data acquisition module. Preliminary testing of the UDCM at the IAEA facilities lead to the following recommendations from the IAEA: Increase the measurement range. Lower range by a factor of 5 and upper range by 2 orders of magnitude; Modifications to the web interface; Increase programmable acquisition time to 3600s; Develop a method to handle current offsets and negative current; Error checking when writing data to the uSD card; and Writingmore » BID files along with the currently stored BI0 files.« less

  2. Digital Signal Processing and Generation for a DC Current Transformer for Particle Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zorzetti, Silvia

    2013-01-01

    The thesis topic, digital signal processing and generation for a DC current transformer, focuses on the most fundamental beam diagnostics in the field of particle accelerators, the measurement of the beam intensity, or beam current. The technology of a DC current transformer (DCCT) is well known, and used in many areas, including particle accelerator beam instrumentation, as non-invasive (shunt-free) method to monitor the DC current in a conducting wire, or in our case, the current of charged particles travelling inside an evacuated metal pipe. So far, custom and commercial DCCTs are entirely based on analog technologies and signal processing, whichmore » makes them inflexible, sensitive to component aging, and difficult to maintain and calibrate.« less

  3. Towards a Quantitative Use of Satellite Remote Sensing in Crop Growth Models for Large Scale Agricultural Production Estimate (Invited)

    NASA Astrophysics Data System (ADS)

    Defourny, P.

    2013-12-01

    The development of better agricultural monitoring capabilities is clearly considered as a critical step for strengthening food production information and market transparency thanks to timely information about crop status, crop area and yield forecasts. The documentation of global production will contribute to tackle price volatility by allowing local, national and international operators to make decisions and anticipate market trends with reduced uncertainty. Several operational agricultural monitoring systems are currently operating at national and international scales. Most are based on the methods derived from the pioneering experiences completed some decades ago, and use remote sensing to qualitatively compare one year to the others to estimate the risks of deviation from a normal year. The GEO Agricultural Monitoring Community of Practice described the current monitoring capabilities at the national and global levels. An overall diagram summarized the diverse relationships between satellite EO and agriculture information. There is now a large gap between the current operational large scale systems and the scientific state of the art in crop remote sensing, probably because the latter mainly focused on local studies. The poor availability of suitable in-situ and satellite data over extended areas hampers large scale demonstrations preventing the much needed up scaling research effort. For the cropland extent, this paper reports a recent research achievement using the full ENVISAT MERIS 300 m archive in the context of the ESA Climate Change Initiative. A flexible combination of classification methods depending to the region of the world allows mapping the land cover as well as the global croplands at 300 m for the period 2008 2012. This wall to wall product is then compared with regards to the FP 7-Geoland 2 results obtained using as Landsat-based sampling strategy over the IGADD countries. On the other hand, the vegetation indices and the biophysical variables such the Green Area Index (GAI), fAPAR and fcover usually retrieved from MODIS, MERIS, SPOT-Vegetation described the quality of the green vegetation development. The GLOBAM (Belgium) and EU FP-7 MOCCCASIN projects (Russia) improved the standard products and were demonstrated over large scale. The GAI retrieved from MODIS time series using a purity index criterion depicted successfully the inter-annual variability. Furthermore, the quantitative assimilation of these GAI time series into a crop growth model improved the yield estimate over years. These results showed that the GAI assimilation works best at the district or provincial level. In the context of the GEO Ag., the Joint Experiment of Crop Assessment and Monitoring (JECAM) was designed to enable the global agricultural monitoring community to compare such methods and results over a variety of regional cropping systems. For a network of test sites around the world, satellite and field measurements are currently collected and will be made available for collaborative effort. This experiment should facilitate international standards for data products and reporting, eventually supporting the development of a global system of systems for agricultural crop assessment and monitoring.

  4. Digital Sequences and a Time Reversal-Based Impact Region Imaging and Localization Method

    PubMed Central

    Qiu, Lei; Yuan, Shenfang; Mei, Hanfei; Qian, Weifeng

    2013-01-01

    To reduce time and cost of damage inspection, on-line impact monitoring of aircraft composite structures is needed. A digital monitor based on an array of piezoelectric transducers (PZTs) is developed to record the impact region of impacts on-line. It is small in size, lightweight and has low power consumption, but there are two problems with the impact alarm region localization method of the digital monitor at the current stage. The first one is that the accuracy rate of the impact alarm region localization is low, especially on complex composite structures. The second problem is that the area of impact alarm region is large when a large scale structure is monitored and the number of PZTs is limited which increases the time and cost of damage inspections. To solve the two problems, an impact alarm region imaging and localization method based on digital sequences and time reversal is proposed. In this method, the frequency band of impact response signals is estimated based on the digital sequences first. Then, characteristic signals of impact response signals are constructed by sinusoidal modulation signals. Finally, the phase synthesis time reversal impact imaging method is adopted to obtain the impact region image. Depending on the image, an error ellipse is generated to give out the final impact alarm region. A validation experiment is implemented on a complex composite wing box of a real aircraft. The validation results show that the accuracy rate of impact alarm region localization is approximately 100%. The area of impact alarm region can be reduced and the number of PZTs needed to cover the same impact monitoring region is reduced by more than a half. PMID:24084123

  5. Optical sensor technology for a noninvasive continuous monitoring of blood components

    NASA Astrophysics Data System (ADS)

    Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut

    2010-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.

  6. The Utility of a Wireless Implantable Hemodynamic Monitoring System in Patients Requiring Mechanical Circulatory Support.

    PubMed

    Feldman, David S; Moazami, Nader; Adamson, Philip B; Vierecke, Juliane; Raval, Nir; Shreenivas, Satya; Cabuay, Barry M; Jimenez, Javier; Abraham, William T; O'Connell, John B; Naka, Yoshifumi

    Proper timing of left ventricular assist device (LVAD) implantation in advanced heart failure patients is not well established and is an area of intense interest. In addition, optimizing LVAD performance after implantation remains difficult and represents a significant clinical need. Implantable hemodynamic monitoring systems may provide physicians with the physiologic information necessary to improve the timing of LVAD implantation as well as LVAD performance when compared with current methods. The CardioMEMS Heart sensor Allows for Monitoirng of Pressures to Improve Outcomes in NYHA Class III heart failure patients (CHAMPION) Trial enrolled 550 previously hospitalized patients with New York Heart Association (NYHA) class III heart failure. All patients were implanted with a pulmonary artery (PA) pressure monitoring system and randomized to a treatment and control groups. In the treatment group, physicians used the hemodynamic information to make heart failure management decisions. This information was not available to physicians for the control group. During an average of 18 month randomized follow-up, 27 patients required LVAD implantation. At the time of PA pressure sensor implantation, patients ultimately requiring advanced therapy had higher PA pressures, lower systemic pressure, and similar cardiac output measurements. Treatment and control patients in the LVAD subgroup had similar clinical profiles at the time of enrollment. There was a trend toward a shorter length of time to LVAD implantation in the treatment group when hemodynamic information was available. After LVAD implantation, most treatment group patients continued to provide physicians with physiologic information from the hemodynamic monitoring system. As expected PA pressures declined significantly post LVAD implant in all patients, but the magnitude of decline was higher in patients with PA pressure monitoring. Implantable hemodynamic monitoring appeared to improve the timing of LVAD implantation as well as optimize LVAD performance when compared with current methods. Further studies are necessary to evaluate these findings in a prospective manner.

  7. Surveillance system and method having parameter estimation and operating mode partitioning

    NASA Technical Reports Server (NTRS)

    Bickford, Randall L. (Inventor)

    2003-01-01

    A system and method for monitoring an apparatus or process asset including partitioning an unpartitioned training data set into a plurality of training data subsets each having an operating mode associated thereto; creating a process model comprised of a plurality of process submodels each trained as a function of at least one of the training data subsets; acquiring a current set of observed signal data values from the asset; determining an operating mode of the asset for the current set of observed signal data values; selecting a process submodel from the process model as a function of the determined operating mode of the asset; calculating a current set of estimated signal data values from the selected process submodel for the determined operating mode; and outputting the calculated current set of estimated signal data values for providing asset surveillance and/or control.

  8. Sensor, method and system of monitoring transmission lines

    DOEpatents

    Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

    2012-10-02

    An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

  9. Analysis and Countermeasure Study on DC Bias of Main Transformer in a City

    NASA Astrophysics Data System (ADS)

    Wang, PengChao; Wang, Hongtao; Song, Xinpu; Gu, Jun; Liu, yong; Wu, weili

    2017-07-01

    According to the December 2015 Guohua Beijing thermal power transformer DC magnetic bias phenomenon, the monitoring data of 24 hours of direct current is analyzed. We find that the maximum DC current is up to 25 and is about 30s for the trend cycle, on this basis, then, of the geomagnetic storm HVDC and subway operation causes comparison of the mechanism, and make a comprehensive analysis of the thermal power plant’s geographical location, surrounding environment and electrical contact etc.. The results show that the main reason for the DC bias of Guohua thermal power transformer is the operation of the subway, and the change of the DC bias current is periodic. Finally, of Guohua thermal power transformer DC magnetic bias control method is studied, the simulation results show that the method of using neutral point with small resistance or capacitance can effectively inhibit the main transformer neutral point current.

  10. The use of liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring of antibiotics in cancer patients.

    PubMed

    El-Najjar, Nahed; Jantsch, Jonathan; Gessner, André

    2017-08-28

    Cancer remains a leading cause of mortality and morbidity worldwide. In addition to organ failure, the most frequent reasons for admission of cancer patients to intensive care units (ICU) are: infections and sepsis. As critically ill, the complexity of the health situation of cancer patients renders the standard antimicrobial regimen more complex and even inadequate which results in increased mortality rates. This is due to pathophysiological changes in the volume of distribution, increased clearance, as well as to organ dysfunction. While in the former cases a decrease in drug efficacy is observed, the hallmark of the latter one is overdosing leading to increased toxicity at the expense of efficacy. Furthermore, an additional risk factor is the potential drug-drug interaction between antibiotics and antineoplastic agents. Therefore, therapeutic drug monitoring (TDM) is a necessity to improve the clinical outcome of antimicrobial therapy in cancer patients. To be applied in routine analysis the method used for TDM should be cheap, fast and highly accurate/sensitive. Furthermore, as ICU patients are treated with a cocktail of antibiotics the method has to cover the simultaneous analysis of antibiotics used as a first/second line of treatment. The aim of the current review is to briefly survey the pitfalls in the current antimicrobial therapy and the central role of TDM in dose adjustment and drug-drug interaction's evaluation. A major section is dedicated to summarize the currently published analytical methods and to shed light on the difficulties and potential problems that can be encountered during method development.

  11. Video Surveillance Captures Student Hand Hygiene Behavior, Reactivity to Observation, and Peer Influence in Kenyan Primary Schools

    PubMed Central

    Pickering, Amy J.; Blum, Annalise G.; Breiman, Robert F.; Ram, Pavani K.; Davis, Jennifer

    2014-01-01

    Background In-person structured observation is considered the best approach for measuring hand hygiene behavior, yet is expensive, time consuming, and may alter behavior. Video surveillance could be a useful tool for objectively monitoring hand hygiene behavior if validated against current methods. Methods Student hand cleaning behavior was monitored with video surveillance and in-person structured observation, both simultaneously and separately, at four primary schools in urban Kenya over a study period of 8 weeks. Findings Video surveillance and in-person observation captured similar rates of hand cleaning (absolute difference <5%, p = 0.74). Video surveillance documented higher hand cleaning rates (71%) when at least one other person was present at the hand cleaning station, compared to when a student was alone (48%; rate ratio  = 1.14 [95% CI 1.01–1.28]). Students increased hand cleaning rates during simultaneous video and in-person monitoring as compared to single-method monitoring, suggesting reactivity to each method of monitoring. This trend was documented at schools receiving a handwashing with soap intervention, but not at schools receiving a sanitizer intervention. Conclusion Video surveillance of hand hygiene behavior yields results comparable to in-person observation among schools in a resource-constrained setting. Video surveillance also has certain advantages over in-person observation, including rapid data processing and the capability to capture new behavioral insights. Peer influence can significantly improve student hand cleaning behavior and, when possible, should be exploited in the design and implementation of school hand hygiene programs. PMID:24676389

  12. The Prospect of using Three-Dimensional Earth Models To Improve Nuclear Explosion Monitoring and Ground Motion Hazard Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zucca, J J; Walter, W R; Rodgers, A J

    2008-11-19

    The last ten years have brought rapid growth in the development and use of three-dimensional (3D) seismic models of Earth structure at crustal, regional and global scales. In order to explore the potential for 3D seismic models to contribute to important societal applications, Lawrence Livermore National Laboratory (LLNL) hosted a 'Workshop on Multi-Resolution 3D Earth Models to Predict Key Observables in Seismic Monitoring and Related Fields' on June 6 and 7, 2007 in Berkeley, California. The workshop brought together academic, government and industry leaders in the research programs developing 3D seismic models and methods for the nuclear explosion monitoring andmore » seismic ground motion hazard communities. The workshop was designed to assess the current state of work in 3D seismology and to discuss a path forward for determining if and how 3D Earth models and techniques can be used to achieve measurable increases in our capabilities for monitoring underground nuclear explosions and characterizing seismic ground motion hazards. This paper highlights some of the presentations, issues, and discussions at the workshop and proposes two specific paths by which to begin quantifying the potential contribution of progressively refined 3D seismic models in critical applied arenas. Seismic monitoring agencies are tasked with detection, location, and characterization of seismic activity in near real time. In the case of nuclear explosion monitoring or seismic hazard, decisions to further investigate a suspect event or to launch disaster relief efforts may rely heavily on real-time analysis and results. Because these are weighty decisions, monitoring agencies are regularly called upon to meticulously document and justify every aspect of their monitoring system. In order to meet this level of scrutiny and maintain operational robustness requirements, only mature technologies are considered for operational monitoring systems, and operational technology necessarily lags contemporary research. Current monitoring practice is to use relatively simple Earth models that generally afford analytical prediction of seismic observables (see Examples of Current Monitoring Practice below). Empirical relationships or corrections to predictions are often used to account for unmodeled phenomena, such as the generation of S-waves from explosions or the effect of 3-dimensional Earth structure on wave propagation. This approach produces fast and accurate predictions in areas where empirical observations are available. However, accuracy may diminish away from empirical data. Further, much of the physics is wrapped into an empirical relationship or correction, which limits the ability to fully understand the physical processes underlying the seismic observation. Every generation of seismology researchers works toward quantitative results, with leaders who are active at or near the forefront of what has been computationally possible. While recognizing that only a 3-dimensional model can capture the full physics of seismic wave generation and propagation in the Earth, computational seismology has, until recently, been limited to simplifying model parameterizations (e.g. 1D Earth models) that lead to efficient algorithms. What is different today is the fact that the largest and fastest machines are at last capable of evaluating the effects of generalized 3D Earth structure, at levels of detail that improve significantly over past efforts, with potentially wide application. Advances in numerical methods to compute travel times and complete seismograms for 3D models are enabling new ways to interpret available data. This includes algorithms such as the Fast Marching Method (Rawlison and Sambridge, 2004) for travel time calculations and full waveform methods such as the spectral element method (SEM; Komatitsch et al., 2002, Tromp et al., 2005), higher order Galerkin methods (Kaser and Dumbser, 2006; Dumbser and Kaser, 2006) and advances in more traditional Cartesian finite difference methods (e.g. Pitarka, 1999; Nilsson et al., 2007). The ability to compute seismic observables using a 3D model is only half of the challenge; models must be developed that accurately represent true Earth structure. Indeed, advances in seismic imaging have followed improvements in 3D computing capability (e.g. Tromp et al., 2005; Rawlinson and Urvoy, 2006). Advances in seismic imaging methods have been fueled in part by theoretical developments and the introduction of novel approaches for combining different seismological observables, both of which can increase the sensitivity of observations to Earth structure. Examples of such developments are finite-frequency sensitivity kernels for body-wave tomography (e.g. Marquering et al., 1998; Montelli et al., 2004) and joint inversion of receiver functions and surface wave group velocities (e.g. Julia et al., 2000).« less

  13. Review: Some low-frequency electrical methods for subsurface characterization and monitoring in hydrogeology

    NASA Astrophysics Data System (ADS)

    Revil, A.; Karaoulis, M.; Johnson, T.; Kemna, A.

    2012-06-01

    Low-frequency geoelectrical methods include mainly self-potential, resistivity, and induced polarization techniques, which have potential in many environmental and hydrogeological applications. They provide complementary information to each other and to in-situ measurements. The self-potential method is a passive measurement of the electrical response associated with the in-situ generation of electrical current due to the flow of pore water in porous media, a salinity gradient, and/or the concentration of redox-active species. Under some conditions, this method can be used to visualize groundwater flow, to determine permeability, and to detect preferential flow paths. Electrical resistivity is dependent on the water content, the temperature, the salinity of the pore water, and the clay content and mineralogy. Time-lapse resistivity can be used to assess the permeability and dispersivity distributions and to monitor contaminant plumes. Induced polarization characterizes the ability of rocks to reversibly store electrical energy. It can be used to image permeability and to monitor chemistry of the pore water-minerals interface. These geophysical methods, reviewed in this paper, should always be used in concert with additional in-situ measurements (e.g. in-situ pumping tests, chemical measurements of the pore water), for instance through joint inversion schemes, which is an area of fertile on-going research.

  14. In vivo sodium concentration continuously monitored with fluorescent sensors.

    PubMed

    Dubach, J Matthew; Lim, Edward; Zhang, Ning; Francis, Kevin P; Clark, Heather

    2011-02-01

    Sodium balance is vital to maintaining normal physiological function. Imbalances can occur in a variety of diseases, during certain surgical operations or during rigorous exercise. There is currently no method to continuously monitor sodium concentration in patients who may be susceptible to hyponatremia. Our approach was to design sodium specific fluorescent sensors capable of measuring physiological fluctuations in sodium concentration. The sensors are submicron plasticized polymer particles containing sodium recognition components that are coated with biocompatible poly(ethylene) glycol. Here, the sensors were brought up in saline and placed in the subcutaneous area of the skin of mice by simple injection. The fluorescence was monitored in real time using a whole animal imager to track changes in sodium concentrations. This technology could be used to monitor certain disease states or warn against dangerously low levels of sodium during exercise.

  15. Omnify: Investigating the Visibility and Effectiveness of Copyright Monitors

    NASA Astrophysics Data System (ADS)

    Potharaju, Rahul; Seibert, Jeff; Fahmy, Sonia; Nita-Rotaru, Cristina

    The arms race between copyright agencies and P2P users is an ongoing and evolving struggle. On the one hand, content providers are using several techniques to stealthily find unauthorized distribution of copyrighted work in order to deal with the problem of Internet piracy. On the other hand, P2P users are relying increasingly on blacklists and anonymization methods in order to avoid detection. In this work, we propose a number of techniques to reveal copyright monitors' current approaches and evaluate their effectiveness. We apply these techniques on data we collected from more than 2.75 million BitTorrent swarms containing 71 million IP addresses. We provide strong evidence that certain nodes are indeed copyright monitors, show that monitoring is a world-wide phenomenon, and devise a methodology for generating blacklists for paranoid and conservative P2P users.

  16. Application of Self Nulling Eddy Current Probe Technique to the Detection of Fatigue Crack Initiation and Control of Test Procedures

    NASA Technical Reports Server (NTRS)

    Namkung, M.; Nath, S.; Wincheski, B.; Fulton, J. P.

    1994-01-01

    A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.

  17. Thermography detection on the fatigue damage

    NASA Astrophysics Data System (ADS)

    Yang, Bing

    It has always been a great temptation in finding new methods to in-situ "watch" the material fatigue-damage processes so that in-time reparations will be possible, and failures or losses can be minimized to the maximum extent. Realizing that temperature patterns may serve as fingerprints for stress-strain behaviors of materials, a state-of-art infrared (IR) thermography camera has been used to "watch" the temperature evolutions of both crystalline and amorphous materials "cycle by cycle" during fatigue experiments in the current research. The two-dimensional (2D) thermography technique records the surface-temperature evolutions of materials. Since all plastic deformations are related to heat dissipations, thermography provides an innovative method to in-situ monitor the heat-evolution processes, including plastic-deformation, mechanical-damage, and phase-transformation characteristics. With the understanding of the temperature evolutions during fatigue, thermography could provide the direct information and evidence of the stress-strain distribution, crack initiation and propagation, shear-band growth, and plastic-zone evolution, which will open up wide applications in studying the structural integrity of engineering components in service. In the current research, theoretical models combining thermodynamics and heat-conduction theory have been developed. Key issues in fatigue, such as in-situ stress-strain states, cyclic softening and hardening observations, and fatigue-life predictions, have been resolved by simply monitoring the specimen-temperature variation during fatigue. Furthermore, in-situ visulizations as well as qualitative and quantitative analyses of fatigue-damage processes, such as Luders-band evolutions, crack propagation, plastic zones, and final fracture, have been performed by thermography. As a method requiring no special sample preparation or surface contact by sensors, thermography provides an innovative and convenient method to in-situ monitor and analyze the mechanical-damage processes of materials and components.

  18. The use of photogrammetric and stereophotogrammetric methods in aerodynamic experiments

    NASA Astrophysics Data System (ADS)

    Shmyreva, V. N.; Iakovlev, V. A.

    The possibilities afforded by photogrammetry and stereophotogrammetry in current aerodynamic experiments, methods of image recording, and observation data processing are briefly reviewed. Some specific experiments illustrating the application of stereophotogrammetry are described. The applications discussed include the monitoring of model position in wind tunnels, determination of model deformations and displacements, determination of the deformations of real structural elements in static strength tests, and solution of a variety of problems in hydrodynamics.

  19. Application of Non-destructive Methods of Stress-strain State at Hazardous Production Facilities

    NASA Astrophysics Data System (ADS)

    Shram, V.; Kravtsova, Ye; Selsky, A.; Bezborodov, Yu; Lysyannikova, N.; Lysyannikov, A.

    2016-06-01

    The paper deals with the sources of accidents in distillation columns, on the basis of which the most dangerous defects are detected. The analysis of the currently existing methods of non-destructive testing of the stress-strain state is performed. It is proposed to apply strain and acoustic emission techniques to continuously monitor dangerous objects, which helps prevent the possibility of accidents, as well as reduce the work.

  20. Performance Analysis of Retrofitted Tribo-Corrosion Test Rig for Monitoring In Situ Oil Conditions.

    PubMed

    Siddaiah, Arpith; Khan, Zulfiqar Ahmad; Ramachandran, Rahul; Menezes, Pradeep L

    2017-09-28

    Oils and lubricants, once extracted after use from a mechanical system, can hardly be reused, and should be refurbished or replaced in most applications. New methods of in situ oil and lubricant efficiency monitoring systems have been introduced for a wide variety of mechanical systems, such as automobiles, aerospace aircrafts, ships, offshore wind turbines, and deep sea oil drilling rigs. These methods utilize electronic sensors to monitor the "byproduct effects" in a mechanical system that are not indicative of the actual remaining lifecycle and reliability of the oils. A reliable oil monitoring system should be able to monitor the wear rate and the corrosion rate of the tribo-pairs due to the inclusion of contaminants. The current study addresses this technological gap, and presents a novel design of a tribo-corrosion test rig for oils used in a dynamic system. A pin-on-disk tribometer test rig retrofitted with a three electrode-potentiostat corrosion monitoring system was used to analyze the corrosion and wear rate of a steel tribo-pair in industrial grade transmission oil. The effectiveness of the retrofitted test rig was analyzed by introducing various concentrations of contaminants in an oil medium that usually leads to a corrosive working environment. The results indicate that the retrofitted test rig can effectively monitor the in situ tribological performance of the oil in a controlled dynamic corrosive environment. It is a useful method to understand the wear-corrosion synergies for further experimental work, and to develop accurate predictive lifecycle assessment and prognostic models. The application of this system is expected to have economic benefits and help reduce the ecological oil waste footprint.

  1. Performance Analysis of Retrofitted Tribo-Corrosion Test Rig for Monitoring In Situ Oil Conditions

    PubMed Central

    Ramachandran, Rahul; Menezes, Pradeep L.

    2017-01-01

    Oils and lubricants, once extracted after use from a mechanical system, can hardly be reused, and should be refurbished or replaced in most applications. New methods of in situ oil and lubricant efficiency monitoring systems have been introduced for a wide variety of mechanical systems, such as automobiles, aerospace aircrafts, ships, offshore wind turbines, and deep sea oil drilling rigs. These methods utilize electronic sensors to monitor the “byproduct effects” in a mechanical system that are not indicative of the actual remaining lifecycle and reliability of the oils. A reliable oil monitoring system should be able to monitor the wear rate and the corrosion rate of the tribo-pairs due to the inclusion of contaminants. The current study addresses this technological gap, and presents a novel design of a tribo-corrosion test rig for oils used in a dynamic system. A pin-on-disk tribometer test rig retrofitted with a three electrode-potentiostat corrosion monitoring system was used to analyze the corrosion and wear rate of a steel tribo-pair in industrial grade transmission oil. The effectiveness of the retrofitted test rig was analyzed by introducing various concentrations of contaminants in an oil medium that usually leads to a corrosive working environment. The results indicate that the retrofitted test rig can effectively monitor the in situ tribological performance of the oil in a controlled dynamic corrosive environment. It is a useful method to understand the wear–corrosion synergies for further experimental work, and to develop accurate predictive lifecycle assessment and prognostic models. The application of this system is expected to have economic benefits and help reduce the ecological oil waste footprint. PMID:28956819

  2. The implications of the precautionary principle for biological monitoring

    NASA Astrophysics Data System (ADS)

    Macgarvin, M.

    1995-03-01

    Marine biological monitoring programmes frequently attempt to determine “safe” levels of contamination, based on assumptions about the assimilative capacity of the environment. This paper argues that such assumptions lack scientific rigour, and do not form the basis upon which a precautionary policy can be built. It notes the problems associated with assessing toxicological effects, but centres its attention on the crucial (yet far less discussed) weaknesses in theoretical ecology that make it extremely unlikely that biological monitoring can determine safe levels of contamination that leave ecosystems unaffected. It is argued that many marine biologists, if pressed, would concede these shortcomings but believe that, in the face of the technical difficulties and high costs of pollution prevention, we have no choice but to use such methods. This paper argues, with examples, that pollution prevention, often with considerable economic savings, is becoming a reality for even the most problematic substances. The difficulty is that the development of “clean production” methods lie outside the sphere of interest of those carrying out monitoring, so that measures that attempt to determine safe levels of contamination continue to be advocated. This gulf needs to be bridged so that the continuation of monitoring programmes that are part of dilute and disperse policies become regarded as inappropriate, indeed unethical. The paper concludes that this does not mean the end of marine monitoring. Instead, reliable methods for assessing physical levels of contamination will be required to determine whether the reduction targets set—as part of the introduction of clean production—are being met. Formidable difficulties will remain, requiring a precautious approach. Nevertheless, monitoring will no longer carry the burden of attempting to demonstrate that a particular level of environmental contamination is safe, which is currently destroying its scientific credibility.

  3. Objectives and metrics for wildlife monitoring

    USGS Publications Warehouse

    Sauer, J.R.; Knutson, M.G.

    2008-01-01

    Monitoring surveys allow managers to document system status and provide the quantitative basis for management decision-making, and large amounts of effort and funding are devoted to monitoring. Still, monitoring surveys often fall short of providing required information; inadequacies exist in survey designs, analyses procedures, or in the ability to integrate the information into an appropriate evaluation of management actions. We describe current uses of monitoring data, provide our perspective on the value and limitations of current approaches to monitoring, and set the stage for 3 papers that discuss current goals and implementation of monitoring programs. These papers were derived from presentations at a symposium at The Wildlife Society's 13th Annual Conference in Anchorage, Alaska, USA. [2006

  4. A comparison of two types of neural network for weld quality prediction in small scale resistance spot welding

    NASA Astrophysics Data System (ADS)

    Wan, Xiaodong; Wang, Yuanxun; Zhao, Dawei; Huang, YongAn

    2017-09-01

    Our study aims at developing an effective quality monitoring system in small scale resistance spot welding of titanium alloy. The measured electrical signals were interpreted in combination with the nugget development. Features were extracted from the dynamic resistance and electrode voltage curve. A higher welding current generally indicated a lower overall dynamic resistance level. A larger electrode voltage peak and higher change rate of electrode voltage could be detected under a smaller electrode force or higher welding current condition. Variation of the extracted features and weld quality was found more sensitive to the change of welding current than electrode force. Different neural network model were proposed for weld quality prediction. The back propagation neural network was more proper in failure load estimation. The probabilistic neural network model was more appropriate to be applied in quality level classification. A real-time and on-line weld quality monitoring system may be developed by taking advantages of both methods.

  5. Real-time combustion control and diagnostics sensor-pressure oscillation monitor

    DOEpatents

    Chorpening, Benjamin T [Morgantown, WV; Thornton, Jimmy [Morgantown, WV; Huckaby, E David [Morgantown, WV; Richards, George A [Morgantown, WV

    2009-07-14

    An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

  6. A Combined EOF/Variational Approach for Mapping Radar-Derived Sea Surface Currents

    DTIC Science & Technology

    2011-01-01

    Section 4 describes the results of experiments with the real observations off the Opal Coast of the Eastern English Channel. It is shown that the...To assess the method’s performance, we conducted twin-data experiments with simulated HFR data (Section 3) and real observations off the Opal Coast...the Opal coast of the Pas de Calais in northern France. 4.1. The data In May-June 2003. two HF radars were deployed to monitor surface currents

  7. Simulation of wear in overhead current collection systems

    NASA Astrophysics Data System (ADS)

    Klapas, D.; Benson, F. A.; Hackam, R.

    1985-09-01

    Apparatus have been designed to simulate the wear from conductors in a railway current collection system. The main features of the wear machine include a continuous monitoring of the strip wear, strip traversing, and dwell-time test facilities for the investigation of oxidational wear on a copper disk, simulating the contact wire. Disk wear is measured in situ by the spherical indentations method. Typical results of the specific wear rate are also presented to demonstrate the capability of the apparatus.

  8. Reliability assessment of multiple quantum well avalanche photodiodes

    NASA Technical Reports Server (NTRS)

    Yun, Ilgu; Menkara, Hicham M.; Wang, Yang; Oguzman, Isamil H.; Kolnik, Jan; Brennan, Kevin F.; May, Gray S.; Wagner, Brent K.; Summers, Christopher J.

    1995-01-01

    The reliability of doped-barrier AlGaAs/GsAs multi-quantum well avalanche photodiodes fabricated by molecular beam epitaxy is investigated via accelerated life tests. Dark current and breakdown voltage were the parameters monitored. The activation energy of the degradation mechanism and median device lifetime were determined. Device failure probability as a function of time was computed using the lognormal model. Analysis using the electron beam induced current method revealed the degradation to be caused by ionic impurities or contamination in the passivation layer.

  9. Diagnostic for two-mode variable valve activation device

    DOEpatents

    Fedewa, Andrew M

    2014-01-07

    A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.

  10. Biphasic DC measurement approach for enhanced measurement stability and multi-channel sampling of self-sensing multi-functional structural materials doped with carbon-based additives

    NASA Astrophysics Data System (ADS)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon; Geiger, Randall

    2017-06-01

    Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real-time utilization of self-sensing materials in structural health monitoring.

  11. Comparison of Exoelectrogenic Bacteria Detected Using Two Different Methods: U-tube Microbial Fuel Cell and Plating Method

    PubMed Central

    Yu, Jaecheul; Cho, Sunja; Kim, Sunah; Cho, Haein; Lee, Taeho

    2012-01-01

    In a microbial fuel cell (MFC), exoelectrogens, which transfer electrons to the electrode, have been regarded as a key factor for electricity generation. In this study, U-tube MFC and plating methods were used to isolate exoelectrogens from the anode of an MFC. Disparate microorganisms were identified depending on isolation methods, despite the use of an identical source. Denaturing gel gradient electrophoresis (DGGE) analysis showed that certain microorganisms became dominant in the U-tube MFC. The predominant bacterium was similar to Ochrobactrum sp., belonging to the Alphaproteobacteria, which was shown to be able to function as an exoelectrogen in a previous study. Three isolates, one affiliated with Bacillus sp. and two with Paenibacillus sp., were identified using the plating method, which belonged to the Gram-positive bacteria, the Firmicutes. The U-tube MFCs were inoculated with the three isolates using the plating method, operated in the batch mode and the current was monitored. All of the U-tube MFCs inoculated with each isolate after isolation from plates produced lower current (peak current density: 3.6–16.3 mA/m2) than those in U-tube MFCs with mixed culture (48.3–62.6 mA/m2). Although the isolates produced low currents, various bacterial groups were found to be involved in current production. PMID:22129603

  12. Wavelet-Based Artifact Identification and Separation Technique for EEG Signals during Galvanic Vestibular Stimulation

    PubMed Central

    Adib, Mani; Cretu, Edmond

    2013-01-01

    We present a new method for removing artifacts in electroencephalography (EEG) records during Galvanic Vestibular Stimulation (GVS). The main challenge in exploiting GVS is to understand how the stimulus acts as an input to brain. We used EEG to monitor the brain and elicit the GVS reflexes. However, GVS current distribution throughout the scalp generates an artifact on EEG signals. We need to eliminate this artifact to be able to analyze the EEG signals during GVS. We propose a novel method to estimate the contribution of the GVS current in the EEG signals at each electrode by combining time-series regression methods with wavelet decomposition methods. We use wavelet transform to project the recorded EEG signal into various frequency bands and then estimate the GVS current distribution in each frequency band. The proposed method was optimized using simulated signals, and its performance was compared to well-accepted artifact removal methods such as ICA-based methods and adaptive filters. The results show that the proposed method has better performance in removing GVS artifacts, compared to the others. Using the proposed method, a higher signal to artifact ratio of −1.625 dB was achieved, which outperformed other methods such as ICA-based methods, regression methods, and adaptive filters. PMID:23956786

  13. Comparison of Enterococcus qPCR analysis results from fresh and marine water samples on two real-time instruments -

    EPA Science Inventory

    EPA is currently considering a quantitative polymerase chain reaction (qPCR) method, targeting Enterococcus spp., for beach monitoring. Improvements in the method’s cost-effectiveness may be realized by the use of newer instrumentation such as the Applied Biosystems StepOneTM a...

  14. Utilization of pyrosequencing to monitor the microbiome dynamics of probiotic treated poultry (Gallus gallus domesticus) during downstream poultry processing

    USDA-ARS?s Scientific Manuscript database

    Antibiotic growth promoters that have been historically employed to control pathogens and increase the rate of animal development for human consumption are currently banned in many countries. Probiotics have been proposed as an alternative to control pathogenic bacteria. Traditional culture method...

  15. Pheromone of the banana-spotting bug, amblypelta lutescens lutescens Distant (Hemiptera: Coreidae): identification, synthesis and field bioassay

    USDA-ARS?s Scientific Manuscript database

    The banana spotting bug Amblypelta lutescens lutescens Distant (Hemiptera: Coreidae) is one of the principal pests of tree fruits and nuts across northern and eastern Australia. Apart from damage assessments in orchards, there are currently no other methods for monitoring bug activity to aid manage...

  16. Isozymes and the genetic resources of forest trees

    Treesearch

    A. H. D. Brown; G. F. Moran

    1981-01-01

    Genetic data are an essential prerequisite for analysing the genetic structure of tree populations. The isozyme technique is the best currently available method for obtaining such data. Despite several shortcomings, isozyme data directly evaluate the genetic resources of forest trees, and can thus be used to monitor and manipulate these resources. For example,...

  17. An efficient estimator to monitor rapidly changing forest conditions

    Treesearch

    Raymond L. Czaplewski; Michael T. Thompson; Gretchen G. Moisen

    2012-01-01

    Extensive expanses of forest often change at a slow pace. In this common situation, FIA produces informative estimates of current status with the Moving Average (MA) method and post-stratification with a remotely sensed map of forest-nonforest cover. However, MA "smoothes out" estimates over time, which confounds analyses of temporal trends; and post-...

  18. COMPARISON OF REAL-TIME PCR FECAL BACTERIA MEASUREMENTS IN RECREATIONAL WATERS USING DIFFERENT INSTRUMENTS AND REAGENT SYSTEMS

    EPA Science Inventory

    U.S. EPA guidance on the safety of surface waters for recreational use is currently based on concentrations of culturable fecal indicator bacteria. Attention is now shifting to more rapid molecular monitoring methods. A multi-year epidemiological study is in progress to determine...

  19. Phage phenomics: Physiological approaches to characterize novel viral proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Savannah E.; Cuevas, Daniel A.; Rostron, Jason E.

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysismore » by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.« less

  20. Phage phenomics: Physiological approaches to characterize novel viral proteins

    DOE PAGES

    Sanchez, Savannah E.; Cuevas, Daniel A.; Rostron, Jason E.; ...

    2015-06-11

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysismore » by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.« less

  1. An illustration of new methods in machine condition monitoring, Part I: stochastic resonance

    NASA Astrophysics Data System (ADS)

    Worden, K.; Antoniadou, I.; Marchesiello, S.; Mba, C.; Garibaldi, L.

    2017-05-01

    There have been many recent developments in the application of data-based methods to machine condition monitoring. A powerful methodology based on machine learning has emerged, where diagnostics are based on a two-step procedure: extraction of damage-sensitive features, followed by unsupervised learning (novelty detection) or supervised learning (classification). The objective of the current pair of papers is simply to illustrate one state-of-the-art procedure for each step, using synthetic data representative of reality in terms of size and complexity. The first paper in the pair will deal with feature extraction. Although some papers have appeared in the recent past considering stochastic resonance as a means of amplifying damage information in signals, they have largely relied on ad hoc specifications of the resonator used. In contrast, the current paper will adopt a principled optimisation-based approach to the resonator design. The paper will also show that a discrete dynamical system can provide all the benefits of a continuous system, but also provide a considerable speed-up in terms of simulation time in order to facilitate the optimisation approach.

  2. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents current state-of-the-art and recent developments in relevant areas such as sorbent research, sampler design, enhanced approaches to analytical quality assurance and on-tube derivatisation. Copyright 2009 Elsevier B.V. All rights reserved.

  3. In situ and online monitoring of hydrodynamic flow profiles in microfluidic channels based upon microelectrochemistry: concept, theory, and validation.

    PubMed

    Amatore, Christian; Oleinick, Alexander; Klymenko, Oleksiy V; Svir, Irina

    2005-08-12

    Herein, we propose a method for reconstructing any plausible macroscopic hydrodynamic flow profile occurring locally within a rectangular microfluidic channel. The method is based on experimental currents measured at single or double microband electrodes embedded in one channel wall. A perfectly adequate quasiconformal mapping of spatial coordinates introduced in our previous work [Electrochem. Commun. 2004, 6, 1123] and an exponentially expanding time grid, initially proposed [J. Electroanal. Chem. 2003, 557, 75] in conjunction with the solution of the corresponding variational problem approached by the Ritz method are used for the numerical reconstruction of flow profiles. Herein, the concept of the method is presented and developed theoretically and its validity is tested on the basis of the use of pseudoexperimental currents emulated by simulation of the diffusion-convection problem in a channel flow cell, to which a random Gaussian current noise is added. The flow profiles reconstructed by our method compare successfully with those introduced a priori into the simulations, even when these include significant distortions compared with either classical Poiseuille or electro-osmotic flows.

  4. Air Pollution Monitoring and Use of Nanotechnology Based Solid State Gas Sensors in Greater Cairo Area, Egypt

    NASA Astrophysics Data System (ADS)

    Ramadan, A. B. A.

    Air pollution is a serious problem in thickly populated and industrialized areas in Egypt, especially in greater Cairo area. Economic growth and industrialization are proceeding at a rapid pace, accompanied by increasing emissions of air polluting sources. Furthermore, though the variety and quantities of polluting sources have increased dramatically, the development of a suitable method for monitoring the pollution causing sources has not followed at the same pace. Environmental impacts of air pollutants have impact on public health, vegetation, material deterioration etc. To prevent or minimize the damage caused by atmospheric pollution, suitable monitoring systems are urgently needed that can rapidly and reliably detect and quantify polluting sources for monitoring by regulating authorities in order to prevent further deterioration of the current pollution levels. Consequently, it is important that the current real-time air quality monitoring system, controlled by the Egyptian Environmental Affairs Agency (EEAA), should be adapted or extended to aid in alleviating this problem. Nanotechnology has been applied to several industrial and domestic fields, for example, applications for gas monitoring systems, gas leak detectors in factories, fire and toxic gas detectors, ventilation control, breath alcohol detectors, and the like. Here we report an application example of studying air quality monitoring based on nanotechnology `solid state gas sensors'. So as to carry out air pollution monitoring over an extensive area, a combination of ground measurements through inexpensive sensors and wireless GIS will be used for this purpose. This portable device, comprising solid state gas sensors integrated to a Personal Digital Assistant (PDA) linked through Bluetooth communication tools and Global Positioning System (GPS), will allow rapid dissemination of information on pollution levels at multiple sites simultaneously.

  5. Virtual Stream Stage Sensor Using Projected Geometry and Augmented Reality for Crowdsourcing Citizen Science Applications

    NASA Astrophysics Data System (ADS)

    Demir, I.; Villanueva, P.; Sermet, M. Y.

    2016-12-01

    Accurately measuring the surface level of a river is a vital component of environmental monitoring and modeling efforts. Reliable data points are required for calibrating the statistical models that are used for, among other things, flood prediction and model validation. While current embedded monitoring systems provide accurate measurements, the cost to replicate this current system on a large scale is prohibitively expensive, limiting the quantity of data available. In this project, we describe a new method to accurately measure river levels using smartphone sensors. We take three pictures of the same point on the river's surface and perform calculations based on the GPS location and spatial orientation of the smartphone for each picture using projected geometry. Augmented reality is used to improve the accuracy of smartphone sensor readings. This proposed implementation is significantly cheaper than existing water measuring systems while offering similar accuracy. Additionally, since the measurements are taken by sensors that are commonly found in smartphones, crowdsourcing the collection of river measurements to citizen-scientists is possible. Thus, our proposed method leads to a much higher quantity of reliable data points than currently possible at a fraction of the cost. Sample runs and an analysis of the results are included. The presentation concludes with a discussion of future work, including applications to other fields and plans to implement a fully automated system using this method in tandem with image recognition and machine learning.

  6. Stratospheric measurement requirements and satellite-borne remote sensing capabilities

    NASA Technical Reports Server (NTRS)

    Carmichael, J. J.; Eldridge, R. G.; Frey, E. J.; Friedman, E. J.; Ghovanlou, A. H.

    1976-01-01

    The capabilities of specific NASA remote sensing systems to provide appropriate measurements of stratospheric parameters for potential user needs were assessed. This was used to evaluate the capabilities of the remote sensing systems to perform global monitoring of the stratosphere. The following conclusions were reached: (1) The performance of current remote stratospheric sensors, in some cases, compares quite well with identified measurement requirements. Their ability to measure other species has not been demonstrated. (2) None of the current, in-situ methods have the capability to satisfy the requirements for global monitoring and the temporal constraints derived from the users needs portion of the study. (3) Existing, non-remote techniques will continue to play an important role in stratospheric investigations for both corroboration of remotely collected data and in the evolutionary development of future remote sensors.

  7. Interface potential sensing from adsorption of human serum albumin (HSA) on carbon nanotube (CNT) monitored by zero current potentiometry for HSA determination.

    PubMed

    Wang, Huan; Wu, Yi; Song, Jun-Feng

    2015-10-15

    In this work, the adsorption of human serum albumin (HSA) on the bare multiwall carbon nanotube (MWNT) was investigated by a new electrochemical method, termed as zero current potentiometry. For this, a MWNT strip was prepared by directly adhering MWNTs on the transparent adhesive tape surface. Moreover, when HSA adsorbed onto MWNT at the MWNT/solution interface, an interface potential Ψ yielded. The interface potential Ψ as the zero current potential Ezcp simply related to it was monitored by zero current potentiometry. The relationship between the zero current potential Ezcp, the HSA concentration and others was established in simple stoichiometric relation. Based on this, both the adsorption of HSA on MWNT and the HSA determination can be studied. For the HSA determination, the theoretic conclusion consisted with experimental results. The zero current potential Ezcp was proportional to the HSA concentration in the range of 2.8 × 10(-8) - 3.4 × 10(-7)M with the limit of detection 2 × 10(-8)M. The linear regression equation was Ezcp/V (vs, SCE) = (0.159 ± 0.01) + (0.358 ± 0.02) × 10(6)CHSA (µM). This determination was fast, high sensitive and good selective. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Potential of Surface Enhanced Raman Spectroscopy (SERS) in Therapeutic Drug Monitoring (TDM). A Critical Review

    PubMed Central

    Jaworska, Aleksandra; Fornasaro, Stefano; Sergo, Valter; Bonifacio, Alois

    2016-01-01

    Surface-Enhanced Raman Spectroscopy (SERS) is a label-free technique that enables quick monitoring of substances at low concentrations in biological matrices. These advantages make it an attractive tool for the development of point-of-care tests suitable for Therapeutic Drug Monitoring (TDM) of drugs with a narrow therapeutic window, such as chemotherapeutic drugs, immunosuppressants, and various anticonvulsants. In this article, the current applications of SERS in the field of TDM for cancer therapy are discussed in detail and illustrated according to the different strategies and substrates. In particular, future perspectives are provided and special concerns regarding the standardization of self-assembly methods and nanofabrication procedures, quality assurance, and technology readiness are critically evaluated. PMID:27657146

  9. Monitoring Drought Conditions in the Navajo Nation Using NASA Earth Observations

    NASA Technical Reports Server (NTRS)

    Ly, Vickie; Gao, Michael; Cary, Cheryl; Turnbull-Appell, Sophie; Surunis, Anton

    2016-01-01

    The Navajo Nation, a 65,700 sq km Native American territory located in the southwestern United States, has been increasingly impacted by severe drought events and changes in climate. These events are coupled with a lack of domestic water infrastructure and economic resources, leaving approximately one-third of the population without access to potable water in their homes. Current methods of monitoring drought are dependent on state-based monthly Standardized Precipitation Index value maps calculated by the Western Regional Climate Center. However, these maps do not provide the spatial resolution needed to illustrate differences in drought severity across the vast Nation. To better understand and monitor drought events and drought regime changes in the Navajo Nation, this project created a geodatabase of historical climate information specific to the area, and a decision support tool to calculate average Standardized Precipitation Index values for user-specified areas. The tool and geodatabase use Tropical Rainfall Monitoring Mission (TRMM) and Global Precipitation Monitor (GPM) observed precipitation data and Parameter-elevation Relationships on Independent Slopes Model modeled historical precipitation data, as well as NASA's modeled Land Data Assimilation Systems deep soil moisture, evaporation, and transpiration data products. The geodatabase and decision support tool will allow resource managers in the Navajo Nation to utilize current and future NASA Earth observation data for increased decision-making capacity regarding future climate change impact on water resources.

  10. Mortality monitoring design for utility-scale solar power facilities

    USGS Publications Warehouse

    Huso, Manuela; Dietsch, Thomas; Nicolai, Chris

    2016-05-27

    IntroductionSolar power represents an important and rapidly expanding component of the renewable energy portfolio of the United States (Lovich and Ennen, 2011; Hernandez and others, 2014). Understanding the impacts of renewable energy development on wildlife is a priority for the U.S. Fish and Wildlife Service (FWS) in compliance with Department of Interior Order No. 3285 (U.S. Department of the Interior, 2009) to “develop best management practices for renewable energy and transmission projects on the public lands to ensure the most environmentally responsible development and delivery of renewable energy.” Recent studies examining effects of renewable energy development on mortality of migratory birds have primarily focused on wind energy (California Energy Commission and California Department of Fish and Game, 2007), and in 2012 the FWS published guidance for addressing wildlife conservation concerns at all stages of land-based wind energy development (U.S. Fish and Wildlife Service, 2012). As yet, no similar guidelines exist for solar development, and no published studies have directly addressed the methodology needed to accurately estimate mortality of birds and bats at solar facilities. In the absence of such guidelines, ad hoc methodologies applied to solar energy projects may lead to estimates of wildlife mortality rates that are insufficiently accurate and precise to meaningfully inform conversations regarding unintended consequences of this energy source and management decisions to mitigate impacts. Although significant advances in monitoring protocols for wind facilities have been made in recent years, there remains a need to provide consistent guidance and study design to quantify mortality of bats, and resident and migrating birds at solar power facilities (Walston and others, 2015).In this document, we suggest methods for mortality monitoring at solar facilities that are based on current methods used at wind power facilities but adapted for the unique conditions encountered at solar facilities. In particular, unlike at wind-power facilities, the unimpeded access to almost all areas within the facilities, the typically flat terrain, and general absence of thick vegetation allow distance-sampling techniques (Buckland and others, 2001, 2004) to be exploited to advantage at industrial solar sites. These protocols build on the work of Nicolai and others (2011), and as our understanding and techniques for monitoring improve, the methods may be further modified to incorporate improvements in the future. We present case studies based on monitoring methods currently implemented at different utility-scale solar facilities to illustrate how distance-sampling techniques may improve overall detectability without substantially increasing costs. Every facility is unique, and the protocols presented may be adapted based on specific monitoring objectives and conditions at each site.We provide guidance for designing monitoring programs whose objective it is to estimate the total number of bird and bat fatalities occurring at a facility over an extended period of time. We address spatial variation in causes of mortality, as well as potential sources of imperfect detection, for example, animals falling in or moving to unsearched areas, carcasses removed by predators, and carcasses missed by searchers. We suggest methods to estimate and account for each source of imperfect detection. This document focuses on monitoring design only and does not discuss approaches for estimating mortality from collected data. The development of statistically sound estimators relevant to the solar context is a current topic of research, although there are already strong foundations for estimation with distance-sampling methods in similar open, arid environments (Anderson and others, 2001; Freilich and others, 2005). Nonetheless, if protocols described in this document are followed, the resulting data will be adequate and sufficient for estimating mortality using newly formulated estimators.

  11. Evaluation of capillary electrophoresis for in-flight ionic contaminant monitoring of SSF potable water

    NASA Technical Reports Server (NTRS)

    Mudgett, Paul D.; Schultz, John R.; Sauer, Richard L.

    1992-01-01

    Until 1989, ion chromatography (IC) was the baseline technology selected for the Specific Ion Analyzer, an in-flight inorganic water quality monitor being designed for Space Station Freedom. Recent developments in capillary electrophoresis (CE) may offer significant savings of consumables, power consumption, and weight/volume allocation, relative to IC technology. A thorough evaluation of CE's analytical capability, however, is necessary before one of the two techniques is chosen. Unfortunately, analytical methods currently available for inorganic CE are unproven for NASA's target list of anions and cations. Thus, CE electrolyte chemistry and methods to measure the target contaminants must be first identified and optimized. This paper reports the status of a study to evaluate CE's capability with regard to inorganic and carboxylate anions, alkali and alkaline earth cations, and transition metal cations. Preliminary results indicate that CE has an impressive selectivity and trace sensitivity, although considerable methods development remains to be performed.

  12. Direct Measurements of the Ozone Production Rate: Methods, Measurements, and Implications for Air Quality Monitoring

    NASA Astrophysics Data System (ADS)

    Brune, W. H.; Baier, B.; Miller, D. O.; Apel, E. C.; Wisthaler, A.; Fried, A.; Cantrell, C. A.; Blake, D. R.; Brown, S. S.; McDuffie, E. E.; Kaser, L.; Long, R.; Weinheimer, A. J.

    2017-12-01

    Ground level ozone pollution remains a health hazard in the United States despite dramatic reductions due to regulatory actions over the past three decades. The key to understanding the link between the ozone precursor gases, nitrogen oxides (NOx) and volatile organic compounds (VOCs), and ozone pollution is the ozone production rate. However, in air quality models, uncertainties in emissions and meteorology hide the true sensitivity of modeled ozone to the chemistry of the ozone production rate. A better way to understand the ozone production rate is to measure it directly. We devised a method for measuring the ozone production rate directly and have deployed it in a few field studies. In this presentation, we will discuss some fairly recent observations, the strengths and weaknesses of the current method, and a path toward routine monitoring of the ozone production rate.

  13. Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy

    NASA Astrophysics Data System (ADS)

    Gueth, P.; Dauvergne, D.; Freud, N.; Létang, J. M.; Ray, C.; Testa, E.; Sarrut, D.

    2013-07-01

    Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations.

  14. Use of Savitzky-Golay Filter for Performances Improvement of SHM Systems Based on Neural Networks and Distributed PZT Sensors.

    PubMed

    de Oliveira, Mario A; Araujo, Nelcileno V S; da Silva, Rodolfo N; da Silva, Tony I; Epaarachchi, Jayantha

    2018-01-08

    A considerable amount of research has focused on monitoring structural damage using Structural Health Monitoring (SHM) technologies, which has had recent advances. However, it is important to note the challenges and unresolved problems that disqualify currently developed monitoring systems. One of the frontline SHM technologies, the Electromechanical Impedance (EMI) technique, has shown its potential to overcome remaining problems and challenges. Unfortunately, the recently developed neural network algorithms have not shown significant improvements in the accuracy of rate and the required processing time. In order to fill this gap in advanced neural networks used with EMI techniques, this paper proposes an enhanced and reliable strategy for improving the structural damage detection via: (1) Savitzky-Golay (SG) filter, using both first and second derivatives; (2) Probabilistic Neural Network (PNN); and, (3) Simplified Fuzzy ARTMAP Network (SFAN). Those three methods were employed to analyze the EMI data experimentally obtained from an aluminum plate containing three attached PZT (Lead Zirconate Titanate) patches. In this present study, the damage scenarios were simulated by attaching a small metallic nut at three different positions in the aluminum plate. We found that the proposed method achieves a hit rate of more than 83%, which is significantly higher than current state-of-the-art approaches. Furthermore, this approach results in an improvement of 93% when considering the best case scenario.

  15. Use of Savitzky–Golay Filter for Performances Improvement of SHM Systems Based on Neural Networks and Distributed PZT Sensors

    PubMed Central

    Araujo, Nelcileno V. S.; da Silva, Rodolfo N.; da Silva, Tony I.; Epaarachchi, Jayantha

    2018-01-01

    A considerable amount of research has focused on monitoring structural damage using Structural Health Monitoring (SHM) technologies, which has had recent advances. However, it is important to note the challenges and unresolved problems that disqualify currently developed monitoring systems. One of the frontline SHM technologies, the Electromechanical Impedance (EMI) technique, has shown its potential to overcome remaining problems and challenges. Unfortunately, the recently developed neural network algorithms have not shown significant improvements in the accuracy of rate and the required processing time. In order to fill this gap in advanced neural networks used with EMI techniques, this paper proposes an enhanced and reliable strategy for improving the structural damage detection via: (1) Savitzky–Golay (SG) filter, using both first and second derivatives; (2) Probabilistic Neural Network (PNN); and, (3) Simplified Fuzzy ARTMAP Network (SFAN). Those three methods were employed to analyze the EMI data experimentally obtained from an aluminum plate containing three attached PZT (Lead Zirconate Titanate) patches. In this present study, the damage scenarios were simulated by attaching a small metallic nut at three different positions in the aluminum plate. We found that the proposed method achieves a hit rate of more than 83%, which is significantly higher than current state-of-the-art approaches. Furthermore, this approach results in an improvement of 93% when considering the best case scenario. PMID:29316693

  16. Electrical Characterization of Semiconductor and Dielectric Materials with a Non-Damaging FastGateTM Probe

    NASA Astrophysics Data System (ADS)

    Robert, Hillard; William, Howland; Bryan, Snyder

    2002-03-01

    Determination of the electrical properties of semiconductor materials and dielectrics is highly desirable since these correlate best to final device performance. The properties of SiO2 and high k dielectrics such as Equivalent Oxide Thickness(EOT), Interface Trap Density(Dit), Oxide Effective Charge(Neff), Flatband Voltage Hysteresis(Delta Vfb), Threshold Voltage(VT) and, bulk properties such as carrier density profile and channel dose are all important parameters that require monitoring during front end processing. Conventional methods for determining these parameters involve the manufacturing of polysilicon or metal gate MOS capacitors and subsequent measurements of capacitance-voltage(CV) and/or current-voltage(IV). These conventional techniques are time consuming and can introduce changes to the materials being monitored. Also, equivalent circuit effects resulting from excessive leakage current, series resistance and stray inductance can introduce large errors in the measured results. In this paper, a new method is discussed that provides rapid determination of these critical parameters and is robust against equivalent circuit errors. This technique uses a small diameter(30 micron), elastically deformed probe to form a gate for MOSCAP CV and IV and can be used to measure either monitor wafers or test areas within scribe lines on product wafers. It allows for measurements of dielectrics thinner than 10 Angstroms. A detailed description and applications such as high k dielectrics, will be presented.

  17. Characterizing Graphene-modified Electrodes for Interfacing with Arduino®-based Devices.

    PubMed

    Arris, Farrah Aida; Ithnin, Mohamad Hafiz; Salim, Wan Wardatul Amani Wan

    2016-08-01

    Portable low-cost platform and sensing systems for identification and quantitative measurement are in high demand for various environmental monitoring applications, especially in field work. Quantifying parameters in the field requires both minimal sample handling and a device capable of performing measurements with high sensitivity and stability. Furthermore, the one-device-fits-all concept is useful for continuous monitoring of multiple parameters. Miniaturization of devices can be achieved by introducing graphene as part of the transducer in an electrochemical sensor. In this project, we characterize graphene deposition methods on glassy-carbon electrodes (GCEs) with the goal of interfacing with an Arduino-based user-friendly microcontroller. We found that a galvanostatic electrochemical method yields the highest peak current of 10 mA, promising a highly sensitive electrochemical sensor. An Atlas Scientific™ printed circuit board (PCB) was connected to an Arduino® microcontroller using a multi-circuit connection that can be interfaced with graphene-based electrochemical sensors for environmental monitoring.

  18. Remote down-hole well telemetry

    DOEpatents

    Briles, Scott D [Los Alamos, NM; Neagley, Daniel L [Albuquerque, NM; Coates, Don M [Santa Fe, NM; Freund, Samuel M [Los Alamos, NM

    2004-07-20

    The present invention includes an apparatus and method for telemetry communication with oil-well monitoring and recording instruments located in the vicinity of the bottom of gas or oil recovery pipes. Such instruments are currently monitored using electrical cabling that is inserted into the pipes; cabling has a short life in this environment, and requires periodic replacement with the concomitant, costly shutdown of the well. Modulated reflectance, a wireless communication method that does not require signal transmission power from the telemetry package will provide a long-lived and reliable way to monitor down-hole conditions. Normal wireless technology is not practical since batteries and capacitors have to frequently be replaced or recharged, again with the well being removed from service. RF energy generated above ground can also be received, converted and stored down-hole without the use of wires, for actuating down-hole valves, as one example. Although modulated reflectance reduces or eliminates the loss of energy at the sensor package because energy is not consumed, during the transmission process, additional stored extra energy down-hole is needed.

  19. Accelerated Aging Experiments for Capacitor Health Monitoring and Prognostics

    NASA Technical Reports Server (NTRS)

    Kulkarni, Chetan S.; Celaya, Jose Ramon; Biswas, Gautam; Goebel, Kai

    2012-01-01

    This paper discusses experimental setups for health monitoring and prognostics of electrolytic capacitors under nominal operation and accelerated aging conditions. Electrolytic capacitors have higher failure rates than other components in electronic systems like power drives, power converters etc. Our current work focuses on developing first-principles-based degradation models for electrolytic capacitors under varying electrical and thermal stress conditions. Prognostics and health management for electronic systems aims to predict the onset of faults, study causes for system degradation, and accurately compute remaining useful life. Accelerated life test methods are often used in prognostics research as a way to model multiple causes and assess the effects of the degradation process through time. It also allows for the identification and study of different failure mechanisms and their relationships under different operating conditions. Experiments are designed for aging of the capacitors such that the degradation pattern induced by the aging can be monitored and analyzed. Experimental setups and data collection methods are presented to demonstrate this approach.

  20. Space and time resolved monitoring of airborne particulate matter in proximity of a traffic roundabout in Sweden.

    PubMed

    Wilkinson, Kai E; Lundkvist, Johanna; Netrval, Julia; Eriksson, Mats; Seisenbaeva, Gulaim A; Kessler, Vadim G

    2013-11-01

    Concerns over exposure to airborne particulate matter (PM) are on the rise. Currently monitoring of PM is done on the basis of interpolating a mass of PM by volume (μg/m(3)) but has the drawback of not taking the chemical nature of PM into account. Here we propose a method of collecting PM at its emission source and employing automated analysis with scanning electron microscopy associated with EDS-analysis together with light scattering to discern the chemical composition, size distribution, and time and space resolved structure of PM emissions in a heavily trafficated roundabout in Sweden. Multivariate methods (PCA, ANOVA) indicate that the technogenic marker Fe follows roadside dust in spreading from the road, and depending on time and location of collection, a statistically significant difference can be seen, adding a useful tool to the repertoiré of detailed PM monitoring and risk assessment of local emission sources. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Valve gape behaviour of mussels (Mytilus edulis) exposed to dispersed crude oil as an environmental monitoring endpoint.

    PubMed

    Redmond, Kirsten J; Berry, Mark; Pampanin, Daniela M; Andersen, Odd Ketil

    2017-04-15

    Environmental monitoring requires cost-effective and efficient methods for detecting potential effects of pollution, and valve gape behaviour has been used with this purpose for a range of contaminants in freshwater and marine bivalves. The current study investigated the use of a new method for measuring valve behaviour responses in mussels (Mytilus edulis) exposed to dispersed crude oil (DCO). Results confirmed that valve gape is a sensitive parameter; at the high DCO concentration (0.25mgL -1 ) the mean valve gape was reduced from 49 to 31%, and mussels increased shell movement (measured as distance travelled) or spent more time closed to avoid contact with the oil. At the low DCO concentration (0.015mgL -1 ) the distance travelled parameter was the most sensitive endpoint. Results also demonstrated that valve gape behaviour is a valid endpoint when monitoring mussels for exposure to DCO. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Priority target conditions for algorithms for monitoring children's growth: Interdisciplinary consensus.

    PubMed

    Scherdel, Pauline; Reynaud, Rachel; Pietrement, Christine; Salaün, Jean-François; Bellaïche, Marc; Arnould, Michel; Chevallier, Bertrand; Piloquet, Hugues; Jobez, Emmanuel; Cheymol, Jacques; Bichara, Emmanuelle; Heude, Barbara; Chalumeau, Martin

    2017-01-01

    Growth monitoring of apparently healthy children aims at early detection of serious conditions through the use of both clinical expertise and algorithms that define abnormal growth. Optimization of growth monitoring requires standardization of the definition of abnormal growth, and the selection of the priority target conditions is a prerequisite of such standardization. To obtain a consensus about the priority target conditions for algorithms monitoring children's growth. We applied a formal consensus method with a modified version of the RAND/UCLA method, based on three phases (preparatory, literature review, and rating), with the participation of expert advisory groups from the relevant professional medical societies (ranging from primary care providers to hospital subspecialists) as well as parent associations. We asked experts in the pilot (n = 11), reading (n = 8) and rating (n = 60) groups to complete the list of diagnostic classification of the European Society for Paediatric Endocrinology and then to select the conditions meeting the four predefined criteria of an ideal type of priority target condition. Strong agreement was obtained for the 8 conditions selected by the experts among the 133 possible: celiac disease, Crohn disease, craniopharyngioma, juvenile nephronophthisis, Turner syndrome, growth hormone deficiency with pituitary stalk interruption syndrome, infantile cystinosis, and hypothalamic-optochiasmatic astrocytoma (in decreasing order of agreement). This national consensus can be used to evaluate the algorithms currently suggested for growth monitoring. The method used for this national consensus could be re-used to obtain an international consensus.

  3. Video surveillance captures student hand hygiene behavior, reactivity to observation, and peer influence in Kenyan primary schools.

    PubMed

    Pickering, Amy J; Blum, Annalise G; Breiman, Robert F; Ram, Pavani K; Davis, Jennifer

    2014-01-01

    In-person structured observation is considered the best approach for measuring hand hygiene behavior, yet is expensive, time consuming, and may alter behavior. Video surveillance could be a useful tool for objectively monitoring hand hygiene behavior if validated against current methods. Student hand cleaning behavior was monitored with video surveillance and in-person structured observation, both simultaneously and separately, at four primary schools in urban Kenya over a study period of 8 weeks. Video surveillance and in-person observation captured similar rates of hand cleaning (absolute difference <5%, p = 0.74). Video surveillance documented higher hand cleaning rates (71%) when at least one other person was present at the hand cleaning station, compared to when a student was alone (48%; rate ratio  = 1.14 [95% CI 1.01-1.28]). Students increased hand cleaning rates during simultaneous video and in-person monitoring as compared to single-method monitoring, suggesting reactivity to each method of monitoring. This trend was documented at schools receiving a handwashing with soap intervention, but not at schools receiving a sanitizer intervention. Video surveillance of hand hygiene behavior yields results comparable to in-person observation among schools in a resource-constrained setting. Video surveillance also has certain advantages over in-person observation, including rapid data processing and the capability to capture new behavioral insights. Peer influence can significantly improve student hand cleaning behavior and, when possible, should be exploited in the design and implementation of school hand hygiene programs.

  4. Adaptive hidden Markov model-based online learning framework for bearing faulty detection and performance degradation monitoring

    NASA Astrophysics Data System (ADS)

    Yu, Jianbo

    2017-01-01

    This study proposes an adaptive-learning-based method for machine faulty detection and health degradation monitoring. The kernel of the proposed method is an "evolving" model that uses an unsupervised online learning scheme, in which an adaptive hidden Markov model (AHMM) is used for online learning the dynamic health changes of machines in their full life. A statistical index is developed for recognizing the new health states in the machines. Those new health states are then described online by adding of new hidden states in AHMM. Furthermore, the health degradations in machines are quantified online by an AHMM-based health index (HI) that measures the similarity between two density distributions that describe the historic and current health states, respectively. When necessary, the proposed method characterizes the distinct operating modes of the machine and can learn online both abrupt as well as gradual health changes. Our method overcomes some drawbacks of the HIs (e.g., relatively low comprehensibility and applicability) based on fixed monitoring models constructed in the offline phase. Results from its application in a bearing life test reveal that the proposed method is effective in online detection and adaptive assessment of machine health degradation. This study provides a useful guide for developing a condition-based maintenance (CBM) system that uses an online learning method without considerable human intervention.

  5. Multiplexed 3D FRET imaging in deep tissue of live embryos

    PubMed Central

    Zhao, Ming; Wan, Xiaoyang; Li, Yu; Zhou, Weibin; Peng, Leilei

    2015-01-01

    Current deep tissue microscopy techniques are mostly restricted to intensity mapping of fluorophores, which significantly limit their applications in investigating biochemical processes in vivo. We present a deep tissue multiplexed functional imaging method that probes multiple Förster resonant energy transfer (FRET) sensors in live embryos with high spatial resolution. The method simultaneously images fluorescence lifetimes in 3D with multiple excitation lasers. Through quantitative analysis of triple-channel intensity and lifetime images, we demonstrated that Ca2+ and cAMP levels of live embryos expressing dual FRET sensors can be monitored simultaneously at microscopic resolution. The method is compatible with a broad range of FRET sensors currently available for probing various cellular biochemical functions. It opens the door to imaging complex cellular circuitries in whole live organisms. PMID:26387920

  6. 'There were more wires than him': the potential for wireless patient monitoring in neonatal intensive care.

    PubMed

    Bonner, Oliver; Beardsall, Kathryn; Crilly, Nathan; Lasenby, Joan

    2017-02-01

    The neonatal intensive care unit (NICU) can be one of the most stressful hospital environments. Alongside providing intensive clinical care, it is important that parents have the opportunity for regular physical contact with their babies because the neonatal period is critical for parent-child bonding. At present, monitoring technology in the NICU requires multiple wired sensors to track each baby's vital signs. This study describes the experiences that parents and nurses have with the current monitoring methods, and reports on their responses to the concept of a wireless monitoring system. Semistructured interviews were conducted with six parents, each of whom had babies on the unit, and seven nurses who cared for those babies. The interviews initially focused on the participants' experiences of the current wired system and then on their responses to the concept of a wireless system. The transcripts were analysed using a general inductive approach to identify relevant themes. Participants reported on physical and psychological barriers to parental care, the ways in which the current system obstructed the efficient delivery of clinical care and the perceived benefits and risks of a wireless system. The parents and nurses identified that the wires impeded baby-parent bonding; physically and psychologically. While a wireless system was viewed as potentially enabling greater interaction, staff and parents highlighted potential concerns, including the size, weight and battery life of any new device. The many wires required to safely monitor babies within the NICU creates a negative environment for parents at a critical developmental period, in terms of physical and psychological interactions. Nurses also experience challenges with the existing system, which could negatively impact the clinical care delivery. Developing a wireless system could overcome these barriers, but there remain challenges in designing a device suitable for this unique environment.

  7. Acoustic Methods to Monitor Protein Crystallization and to Detect Protein Crystals in Suspensions of Agarose and Lipidic Cubic Phase.

    PubMed

    Ericson, Daniel L; Yin, Xingyu; Scalia, Alexander; Samara, Yasmin N; Stearns, Richard; Vlahos, Harry; Ellson, Richard; Sweet, Robert M; Soares, Alexei S

    2016-02-01

    Improvements needed for automated crystallography include crystal detection and crystal harvesting. A technique that uses acoustic droplet ejection to harvest crystals was previously reported. Here a method is described for using the same acoustic instrument to detect protein crystals and to monitor crystal growth. Acoustic pulses were used to monitor the progress of crystallization trials and to detect the presence and location of protein crystals. Crystals were detected, and crystallization was monitored in aqueous solutions and in lipidic cubic phase. Using a commercially available acoustic instrument, crystals measuring ~150 µm or larger were readily detected. Simple laboratory techniques were used to increase the sensitivity to 50 µm by suspending the crystals away from the plastic surface of the crystallization plate. This increased the sensitivity by separating the strong signal generated by the plate bottom that can mask the signal from small protein crystals. It is possible to further boost the acoustic reflection from small crystals by reducing the wavelength of the incident sound pulse, but our current instrumentation does not allow this option. In the future, commercially available sound-emitting transducers with a characteristic frequency near 300 MHz should detect and monitor the growth of individual 3 µm crystals. © 2015 Society for Laboratory Automation and Screening.

  8. Intraoperative laser speckle contrast imaging for monitoring cerebral blood flow: results from a 10-patient pilot study

    NASA Astrophysics Data System (ADS)

    Richards, Lisa M.; Weber, Erica L.; Parthasarathy, Ashwin B.; Kappeler, Kaelyn L.; Fox, Douglas J.; Dunn, Andrew K.

    2012-02-01

    Monitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. Although multiple intraoperative vascular monitoring technologies are currently available, a quantitative method that allows for continuous monitoring is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging method with high spatial and temporal resolution that has been widely used to image CBF in animal models in vivo. In this pilot clinical study, we adapted a Zeiss OPMI Pentero neurosurgical microscope to obtain LSCI images by attaching a camera and a laser diode. This LSCI adapted instrument has been used to acquire full field flow images from 10 patients during tumor resection procedures. The patient's ECG was recorded during acquisition and image registration was performed in post-processing to account for pulsatile motion artifacts. Digital photographs confirmed alignment of vasculature and flow images in four cases, and a relative change in blood flow was observed in two patients after bipolar cautery. The LSCI adapted instrument has the capability to produce real-time, full field CBF image maps with excellent spatial resolution and minimal intervention to the surgical procedure. Results from this study demonstrate the feasibility of using LSCI to monitor blood flow during neurosurgery.

  9. Acoustic Methods to Monitor Protein Crystallization and to Detect Protein Crystals in Suspensions of Agarose and Lipidic Cubic Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ericson, Daniel L.; Yin, Xingyu; Scalia, Alexander

    2016-02-01

    Improvements needed for automated crystallography include crystal detection and crystal harvesting. A technique that uses acoustic droplet ejection to harvest crystals was previously reported. Here a method is described for using the same acoustic instrument to detect protein crystals and to monitor crystal growth. Acoustic pulses were used to monitor the progress of crystallization trials and to detect the presence and location of protein crystals. Crystals were detected, and crystallization was monitored in aqueous solutions and in lipidic cubic phase. Using a commercially available acoustic instrument, crystals measuring ~150 µm or larger were readily detected. Simple laboratory techniques were usedmore » to increase the sensitivity to 50 µm by suspending the crystals away from the plastic surface of the crystallization plate. This increased the sensitivity by separating the strong signal generated by the plate bottom that can mask the signal from small protein crystals. It is possible to further boost the acoustic reflection from small crystals by reducing the wavelength of the incident sound pulse, but our current instrumentation does not allow this option. In the future, commercially available sound-emitting transducers with a characteristic frequency near 300 MHz should detect and monitor the growth of individual 3 µm crystals.« less

  10. Recent developments in sensing methods for eutrophying nutrients with a focus on automation for environmental applications.

    PubMed

    Duffy, G; Regan, F

    2017-11-20

    The demand for autonomous sensors for unattended, continuous nutrient monitoring in water is rapidly growing with the increasing need for more frequent and widespread environmental pollution monitoring. Legislative bodies, local authorities and industries all require frequent water quality monitoring, however, this is time and labour intensive, and an expensive undertaking. Autonomous sensors allow for frequent, unattended data collection. While this solves the time and labour intensive aspects of water monitoring, sensors can be very expensive. Development of low-cost sensors is essential to realise the concept of Internet of Things (IoT). However there is much work yet to be done in this field. This article reviews current literature on the research and development efforts towards deployable autonomous sensors for phosphorus (in the form of phosphate) and nitrogen (in the form of nitrate), with a focus on analytical performance and cost considerations. Additionally, some recent sensing approaches that could be automated in the future are included, along with an overview of approaches to monitoring both nutrients. These approaches are compared with standard laboratory methods and also with commercially available sensors for both phosphate and nitrate. Application of nutrient sensors in agriculture is discussed as an example of how sensor networks can provide improvements in decision making.

  11. On-line and real-time diagnosis method for proton membrane fuel cell (PEMFC) stack by the superposition principle

    NASA Astrophysics Data System (ADS)

    Lee, Young-Hyun; Kim, Jonghyeon; Yoo, Seungyeol

    2016-09-01

    The critical cell voltage drop in a stack can be followed by stack defect. A method of detecting defective cell is the cell voltage monitoring. The other methods are based on the nonlinear frequency response. In this paper, the superposition principle for the diagnosis of PEMFC stack is introduced. If critical cell voltage drops exist, the stack behaves as a nonlinear system. This nonlinearity can explicitly appear in the ohmic overpotential region of a voltage-current curve. To detect the critical cell voltage drop, a stack is excited by two input direct test-currents which have smaller amplitude than an operating stack current and have an equal distance value from the operating current. If the difference between one voltage excited by a test current and the voltage excited by a load current is not equal to the difference between the other voltage response and the voltage excited by the load current, the stack system acts as a nonlinear system. This means that there is a critical cell voltage drop. The deviation from the value zero of the difference reflects the grade of the system nonlinearity. A simulation model for the stack diagnosis is developed based on the SPP, and experimentally validated.

  12. Temperature and current coefficients of lasing wavelength in tunable diode laser spectroscopy.

    PubMed

    Fukuda, M; Mishima, T; Nakayama, N; Masuda, T

    2010-08-01

    The factors determining temperature and current coefficients of lasing wavelength are investigated and discussed under monitoring CO(2)-gas absorption spectra. The diffusion rate of Joule heating at the active layer to the surrounding region is observed by monitoring the change in the junction voltage, which is a function of temperature and the wavelength (frequency) deviation under sinusoidal current modulation. Based on the experimental results, the time interval of monitoring the wavelength after changing the ambient temperature or injected current (scanning rate) has to be constant at least to eliminate the monitoring error induced by the deviation of lasing wavelength, though the temperature and current coefficients of lasing wavelength differ with the rate.

  13. Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy Mcjunkin; Dennis C. Kunerth; Corrie Nichol

    2013-07-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less

  14. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.

    2014-02-18

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less

  15. Towards real time diagnostics of Hybrid Welding Laser/GMAW

    NASA Astrophysics Data System (ADS)

    McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.; Todorov, E.; Levesque, S.

    2014-02-01

    Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

  16. Detection of fatigue cracks by nondestructive testing methods

    NASA Technical Reports Server (NTRS)

    Anderson, R. T.; Delacy, T. J.; Stewart, R. C.

    1973-01-01

    The effectiveness was assessed of various NDT methods to detect small tight cracks by randomly introducing fatigue cracks into aluminum sheets. The study included optimizing NDT methods calibrating NDT equipment with fatigue cracked standards, and evaluating a number of cracked specimens by the optimized NDT methods. The evaluations were conducted by highly trained personnel, provided with detailed procedures, in order to minimize the effects of human variability. These personnel performed the NDT on the test specimens without knowledge of the flaw locations and reported on the flaws detected. The performance of these tests was measured by comparing the flaws detected against the flaws present. The principal NDT methods utilized were radiographic, ultrasonic, penetrant, and eddy current. Holographic interferometry, acoustic emission monitoring, and replication methods were also applied on a reduced number of specimens. Generally, the best performance was shown by eddy current, ultrasonic, penetrant and holographic tests. Etching provided no measurable improvement, while proof loading improved flaw detectability. Data are shown that quantify the performances of the NDT methods applied.

  17. Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery.

    PubMed

    Petrovic, Stanislava; Bogavac-Stanojevic, Natasa; Lakic, Dragana; Peco-Antic, Amira; Vulicevic, Irena; Ivanisevic, Ivana; Kotur-Stevuljevic, Jelena; Jelic-Ivanovic, Zorana

    2015-01-01

    Acute kidney injury (AKI) is significant problem in children with congenital heart disease (CHD) who undergo cardiac surgery. The economic impact of a biomarker-based diagnostic strategy for AKI in pediatric populations undergoing CHD surgery is unknown. The aim of this study was to perform the cost effectiveness analysis of using serum cystatin C (sCysC), urine neutrophil gelatinase-associated lipocalin (uNGAL) and urine liver fatty acid-binding protein (uL-FABP) for the diagnosis of AKI in children after cardiac surgery compared with current diagnostic method (monitoring of serum creatinine (sCr) level). We developed a decision analytical model to estimate incremental cost-effectiveness of different biomarker-based diagnostic strategies compared to current diagnostic strategy. The Markov model was created to compare the lifetime cost associated with using of sCysC, uNGAL, uL-FABP with monitoring of sCr level for the diagnosis of AKI. The utility measurement included in the analysis was quality-adjusted life years (QALY). The results of the analysis are presented as the incremental cost-effectiveness ratio (ICER). Analysed biomarker-based diagnostic strategies for AKI were cost-effective compared to current diagnostic method. However, uNGAL and sCys C strategies yielded higher costs and lower effectiveness compared to uL-FABP strategy. uL-FABP added 1.43 QALY compared to current diagnostic method at an additional cost of $8521.87 per patient. Therefore, ICER for uL-FABP compared to sCr was $5959.35/QALY. Our results suggest that the use of uL-FABP would represent cost effective strategy for early diagnosis of AKI in children after cardiac surgery.

  18. Anticipatory Monitoring and Control of Complex Systems using a Fuzzy based Fusion of Support Vector Regressors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miltiadis Alamaniotis; Vivek Agarwal

    This paper places itself in the realm of anticipatory systems and envisions monitoring and control methods being capable of making predictions over system critical parameters. Anticipatory systems allow intelligent control of complex systems by predicting their future state. In the current work, an intelligent model aimed at implementing anticipatory monitoring and control in energy industry is presented and tested. More particularly, a set of support vector regressors (SVRs) are trained using both historical and observed data. The trained SVRs are used to predict the future value of the system based on current operational system parameter. The predicted values are thenmore » inputted to a fuzzy logic based module where the values are fused to obtain a single value, i.e., final system output prediction. The methodology is tested on real turbine degradation datasets. The outcome of the approach presented in this paper highlights the superiority over single support vector regressors. In addition, it is shown that appropriate selection of fuzzy sets and fuzzy rules plays an important role in improving system performance.« less

  19. Parent-Child Discrepancies in Reports of Parental Monitoring and Their Relationship to Adolescent Alcohol-Related Behaviors.

    PubMed

    Abar, Caitlin C; Jackson, Kristina M; Colby, Suzanne M; Barnett, Nancy P

    2015-09-01

    Discrepancies between parents and adolescents regarding parenting behaviors have been hypothesized to represent a deficit in the parent-child relationship and may represent unique risk factors for poor developmental outcomes. The current study examined the predictive utility of multiple methods for characterizing discrepancies in parents' and adolescents' reports of parental monitoring on youth alcohol use behaviors in order to inform future study design and predictive modeling. Data for the current study came from a prospective investigation of alcohol initiation and progression. The analyzed sample consisted of 606 adolescents (6th-8th grade; 54 % female) and their parents were surveyed at baseline, with youth followed up 12 months later. A series of hierarchical logistic regressions were performed for each monitoring-related construct examined (parental knowledge, parental control, parental solicitation, and child disclosure). The results showed that adolescents' reports were more closely related to outcomes than parents' reports, while greater discrepancies were frequently found to be uniquely associated with greater likelihood of alcohol use behaviors. Implications for future work incorporating parents' and adolescents' reports are discussed.

  20. a Study on Satellite Diagnostic Expert Systems Using Case-Based Approach

    NASA Astrophysics Data System (ADS)

    Park, Young-Tack; Kim, Jae-Hoon; Park, Hyun-Soo

    1997-06-01

    Many research works are on going to monitor and diagnose diverse malfunctions of satellite systems as the complexity and number of satellites increase. Currently, many works on monitoring and diagnosis are carried out by human experts but there are needs to automate much of the routine works of them. Hence, it is necessary to study on using expert systems which can assist human experts routine work by doing automatically, thereby allow human experts devote their expertise more critical and important areas of monitoring and diagnosis. In this paper, we are employing artificial intelligence techniques to model human experts' knowledge and inference the constructed knowledge. Especially, case-based approaches are used to construct a knowledge base to model human expert capabilities which use previous typical exemplars. We have designed and implemented a prototype case-based system for diagnosing satellite malfunctions using cases. Our system remembers typical failure cases and diagnoses a current malfunction by indexing the case base. Diverse methods are used to build a more user friendly interface which allows human experts can build a knowledge base in as easy way.

  1. Evaluating Mobile Survey Tools (MSTs) for Field-Level Monitoring and Data Collection: Development of a Novel Evaluation Framework, and Application to MSTs for Rural Water and Sanitation Monitoring

    PubMed Central

    Fisher, Michael B.; Mann, Benjamin H.; Cronk, Ryan D.; Shields, Katherine F.; Klug, Tori L.; Ramaswamy, Rohit

    2016-01-01

    Information and communications technologies (ICTs) such as mobile survey tools (MSTs) can facilitate field-level data collection to drive improvements in national and international development programs. MSTs allow users to gather and transmit field data in real time, standardize data storage and management, automate routine analyses, and visualize data. Dozens of diverse MST options are available, and users may struggle to select suitable options. We developed a systematic MST Evaluation Framework (EF), based on International Organization for Standardization/International Electrotechnical Commission (ISO/IEC) software quality modeling standards, to objectively assess MSTs and assist program implementers in identifying suitable MST options. The EF is applicable to MSTs for a broad variety of applications. We also conducted an MST user survey to elucidate needs and priorities of current MST users. Finally, the EF was used to assess seven MSTs currently used for water and sanitation monitoring, as a validation exercise. The results suggest that the EF is a promising method for evaluating MSTs. PMID:27563916

  2. Evaluating Mobile Survey Tools (MSTs) for Field-Level Monitoring and Data Collection: Development of a Novel Evaluation Framework, and Application to MSTs for Rural Water and Sanitation Monitoring.

    PubMed

    Fisher, Michael B; Mann, Benjamin H; Cronk, Ryan D; Shields, Katherine F; Klug, Tori L; Ramaswamy, Rohit

    2016-08-23

    Information and communications technologies (ICTs) such as mobile survey tools (MSTs) can facilitate field-level data collection to drive improvements in national and international development programs. MSTs allow users to gather and transmit field data in real time, standardize data storage and management, automate routine analyses, and visualize data. Dozens of diverse MST options are available, and users may struggle to select suitable options. We developed a systematic MST Evaluation Framework (EF), based on International Organization for Standardization/International Electrotechnical Commission (ISO/IEC) software quality modeling standards, to objectively assess MSTs and assist program implementers in identifying suitable MST options. The EF is applicable to MSTs for a broad variety of applications. We also conducted an MST user survey to elucidate needs and priorities of current MST users. Finally, the EF was used to assess seven MSTs currently used for water and sanitation monitoring, as a validation exercise. The results suggest that the EF is a promising method for evaluating MSTs.

  3. Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

    DOEpatents

    McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.

    2010-12-21

    Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

  4. Anaerobic digestion of food waste: A review focusing on process stability.

    PubMed

    Li, Lei; Peng, Xuya; Wang, Xiaoming; Wu, Di

    2018-01-01

    Food waste (FW) is rich in biomass energy, and increasing numbers of national programs are being established to recover energy from FW using anaerobic digestion (AD). However process instability is a common operational issue for AD of FW. Process monitoring and control as well as microbial management can be used to control instability and increase the energy conversion efficiency of anaerobic digesters. Here, we review research progress related to these methods and identify existing limitations to efficient AD; recommendations for future research are also discussed. Process monitoring and control are suitable for evaluating the current operational status of digesters, whereas microbial management can facilitate early diagnosis and process optimization. Optimizing and combining these two methods are necessary to improve AD efficiency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Mitochondria-specific photoactivation to monitor local sphingosine metabolism and function

    PubMed Central

    Feng, Suihan; Harayama, Takeshi; Montessuit, Sylvie; David, Fabrice PA; Winssinger, Nicolas; Martinou, Jean-Claude

    2018-01-01

    Photoactivation ('uncaging’) is a powerful approach for releasing bioactive small-molecules in living cells. Current uncaging methods are limited by the random distribution of caged molecules within cells. We have developed a mitochondria-specific photoactivation method, which permitted us to release free sphingosine inside mitochondria and thereafter monitor local sphingosine metabolism by lipidomics. Our results indicate that sphingosine was quickly phosphorylated into sphingosine 1-phosphate (S1P) driven by sphingosine kinases. In time-course studies, the mitochondria-specific uncaged sphingosine demonstrated distinct metabolic patterns compared to globally-released sphingosine, and did not induce calcium spikes. Our data provide direct evidence that sphingolipid metabolism and signaling are highly dependent on the subcellular location and opens up new possibilities to study the effects of lipid localization on signaling and metabolic fate. PMID:29376826

  6. AIM - Agile Instrumented Monitoring for Improving User Experience of Participation in HealthIT Development.

    PubMed

    Pitkänen, Janne; Nieminen, Marko

    2017-01-01

    Participation of healthcare professionals in information technology development has emerged as an important challenge. As end-users, the professionals are willing to participate in the development activities, but their experiences on the current methods of participation remain mostly negative. There is lack of applicable methods for meeting the needs of agile development approach and scaling up to the largest implementation projects, while maintaining the interest of the professional users to participate in development activities and keeping up their ability to continue working in a productive manner. In this paper, we describe the Agile Instrumented Monitoring as a methodology, based on the methods of instrumented usability evaluation, for improving user experience in HealthIT development. The contribution of the proposed methodology is analyzed in relation to activities of whole iteration cycle and chosen usability evaluation methods, while the user experience of participation is addressed regarding healthcare professionals. Prospective weak and strong market tests for AIM are discussed in the conclusions for future work.

  7. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  8. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  9. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  10. Space shuttle onboard navigation console expert/trainer system

    NASA Technical Reports Server (NTRS)

    Wang, Lui; Bochsler, Dan

    1987-01-01

    A software system for use in enhancing operational performance as well as training ground controllers in monitoring onboard Space Shuttle navigation sensors is described. The Onboard Navigation (ONAV) development reflects a trend toward following a structured and methodical approach to development. The ONAV system must deal with integrated conventional and expert system software, complex interfaces, and implementation limitations due to the target operational environment. An overview of the onboard navigation sensor monitoring function is presented, along with a description of guidelines driving the development effort, requirements that the system must meet, current progress, and future efforts.

  11. Artificial Intelligence in Autonomous Telescopes

    NASA Astrophysics Data System (ADS)

    Mahoney, William; Thanjavur, Karun

    2011-03-01

    Artificial Intelligence (AI) is key to the natural evolution of today's automated telescopes to fully autonomous systems. Based on its rapid development over the past five decades, AI offers numerous, well-tested techniques for knowledge based decision making essential for real-time telescope monitoring and control, with minimal - and eventually no - human intervention. We present three applications of AI developed at CFHT for monitoring instantaneous sky conditions, assessing quality of imaging data, and a prototype for scheduling observations in real-time. Closely complementing the current remote operations at CFHT, we foresee further development of these methods and full integration in the near future.

  12. Novel Authentication of Monitoring Data Through the use of Secret and Public Cryptographic Keys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benz, Jacob M.; Tolk, Keith; Tanner, Jennifer E.

    The Office of Nuclear Verification (ONV) is supporting the development of a piece of equipment to provide data authentication and protection for a suite of monitoring sensors as part of a larger effort to create an arms control technology toolkit. This device, currently called the Red Box, leverages the strengths of both secret and public cryptographic keys to authenticate, digitally sign, and pass along monitoring data to allow for host review, and redaction if necessary, without the loss of confidence in the authenticity of the data by the monitoring party. The design of the Red Box will allow for themore » addition and removal of monitoring equipment and can also verify that the data was collected by authentic monitoring equipment prior to signing the data and sending it to the host and for review. The host will then forward the data to the monitor for review and inspection. This paper will highlight the progress to date of the Red Box development, and will explain the novel method of leveraging both symmetric and asymmetric (secret and public key) cryptography to authenticate data within a warhead monitoring regime.« less

  13. Monitoring Physical and Biogeochemical Dynamics of Uranium Bioremediation at the Intermediate Scale

    NASA Astrophysics Data System (ADS)

    Tarrell, A. N.; Figueroa, L. A.; Rodriguez, D.; Haas, A.; Revil, A.

    2011-12-01

    Subsurface uranium above desired levels for aquifer use categories exists naturally and from historic mining and milling practices. In situ bioimmobilization offers a cost effective alternative to conventional pump and treat methods by stimulating growth of microorganisms that lead to the reduction and precipitation of uranium. Vital to the long-term success of in situ bioimmobilization is the ability to successfully predict and demonstrate treatment effectiveness to assure that regulatory goals are met. However, successfully monitoring the progress over time is difficult and requires long-term stewardship to ensure effective treatment due to complex physical and biogeochemical heterogeneity. In order to better understand these complexities and the resultant effect on uranium immobilization, innovative systematic monitoring approaches with multiple performance indicators must be investigated. A key issue for uranium bioremediation is the long term stability of solid-phase reduction products. It has been shown that a combination of data from electrode-based monitoring, self-potential monitoring, oxidation reduction potential (ORP), and water level sensors provides insight for identifying and localizing bioremediation activity and can provide better predictions of deleterious biogeochemical change such as pore clogging. In order to test the proof-of-concept of these sensing techniques and to deconvolve redox activity from other electric potential changing events, an intermediate scale 3D tank experiment has been developed. Well-characterized materials will be packed into the tank and an artificial groundwater will flow across the tank through a constant-head boundary. The experiment will utilize these sensing methods to image the electrical current produced by bacteria as well as indications of when and where electrical activity is occurring, such as with the reduction of radionuclides. This work will expand upon current knowledge by exploring the behavior of uranium bioremediation at an intermediate scale, as well as examining the effects from introducing a flow field in a laboratory setting. Data collected from this experiment will help further characterize which factors are contributing to current increases. Additional information concerning the effect of geochemical changes in porosity may also be observed. The results of this work will allow the creation of a new data set collected from a more comprehensive laboratory monitoring network and will allow stakeholders to develop effective decision-making tools on the long-term remediation management at uranium contaminated sites. The data will also aid in the long-term prediction abilities of a reactive transport models. As in situ bioremediation offers a low cost alternative to ex situ treatment methods, the results of this work will help to both reduce cost at existing sites and enable treatment of sites that otherwise have no clear solution.

  14. Measuring the arterial-induced skin vibration by geometrical moiré fringe

    NASA Astrophysics Data System (ADS)

    Chiu, Shih-Yung; Wang, Chun-Hsiung; Lee, Shu-Sheng; Wu, Wen-Jong; Hsu, Yu-Hsiang; Lee, Chih-Kung

    2018-02-01

    The demand for self-measured blood pressure self-monitoring device has much increased due to cardiovascular diseases have become leading causes of death for aging population. Currently, the primary non-invasive blood pressure monitoring method is cuff-based. It is well developed and accurate. However, the measuring process is not comfortable, and it cannot provide a continuous measurement. To overcome this problem, methods such as tonometry, volume clamp method, photoplethysmography, pulse wave velocity, and pulse transit time are reported. However, the limited accuracy hindered its application for diagnostics. To perform sequential blood pressure measurement with a high accuracy and long-term examination, we apply moiré interferometry to measure wrist skin vibration induced by radial artery. To achieve this goal, we developed a miniaturized device that can perform moiré interferometry around the wrist region. The 0.4-mm-pitched binary grating and tattoo sticker with 0.46 mm-pitched stripe pattern are used to perform geometric moiré. We demonstrated that the sensitivity and accuracy of this integrated system were sufficient to monitor arterialinduced skin vibration non-invasively. Our developed system was validated with ECG signals collected by a commercial system. According to our studies from measurement, the repeatability of wrist pulsation measurement was achieved with an accuracy of 99.1% in heart rate. A good repeatability of wrist pulse measurement was achieved. Simulations and experiments are both conducted in this paper and prove of geometrical moiré method a suitable technique for arterial-induced skin vibration monitoring.

  15. Impedance-based structural health monitoring of wind turbine blades

    NASA Astrophysics Data System (ADS)

    Pitchford, Corey; Grisso, Benjamin L.; Inman, Daniel J.

    2007-04-01

    Wind power is a fast-growing source of non-polluting, renewable energy with vast potential. However, current wind turbine technology must be improved before the potential of wind power can be fully realized. Wind turbine blades are one of the key components in improving this technology. Blade failure is very costly because it can damage other blades, the wind turbine itself, and possibly other wind turbines. A successful damage detection system incorporated into wind turbines could extend blade life and allow for less conservative designs. A damage detection method which has shown promise on a wide variety of structures is impedance-based structural health monitoring. The technique utilizes small piezoceramic (PZT) patches attached to a structure as self-sensing actuators to both excite the structure with high-frequency excitations, and monitor any changes in structural mechanical impedance. By monitoring the electrical impedance of the PZT, assessments can be made about the integrity of the mechanical structure. Recently, advances in hardware systems with onboard computing, including actuation and sensing, computational algorithms, and wireless telemetry, have improved the accessibility of the impedance method for in-field measurements. This paper investigates the feasibility of implementing such an onboard system inside of turbine blades as an in-field method of damage detection. Viability of onboard detection is accomplished by running a series of tests to verify the capability of the method on an actual wind turbine blade section from an experimental carbon/glass/balsa composite blade developed at Sandia National Laboratories.

  16. Design of an Air Pollution Monitoring Campaign in Beijing for Application to Cohort Health Studies.

    PubMed

    Vedal, Sverre; Han, Bin; Xu, Jia; Szpiro, Adam; Bai, Zhipeng

    2017-12-15

    No cohort studies in China on the health effects of long-term air pollution exposure have employed exposure estimates at the fine spatial scales desirable for cohort studies with individual-level health outcome data. Here we assess an array of modern air pollution exposure estimation approaches for assigning within-city exposure estimates in Beijing for individual pollutants and pollutant sources to individual members of a cohort. Issues considered in selecting specific monitoring data or new monitoring campaigns include: needed spatial resolution, exposure measurement error and its impact on health effect estimates, spatial alignment and compatibility with the cohort, and feasibility and expense. Sources of existing data largely include administrative monitoring data, predictions from air dispersion or chemical transport models and remote sensing (specifically satellite) data. New air monitoring campaigns include additional fixed site monitoring, snapshot monitoring, passive badge or micro-sensor saturation monitoring and mobile monitoring, as well as combinations of these. Each of these has relative advantages and disadvantages. It is concluded that a campaign in Beijing that at least includes a mobile monitoring component, when coupled with currently available spatio-temporal modeling methods, should be strongly considered. Such a campaign is economical and capable of providing the desired fine-scale spatial resolution for pollutants and sources.

  17. Design of an Air Pollution Monitoring Campaign in Beijing for Application to Cohort Health Studies

    PubMed Central

    Vedal, Sverre; Han, Bin; Szpiro, Adam; Bai, Zhipeng

    2017-01-01

    No cohort studies in China on the health effects of long-term air pollution exposure have employed exposure estimates at the fine spatial scales desirable for cohort studies with individual-level health outcome data. Here we assess an array of modern air pollution exposure estimation approaches for assigning within-city exposure estimates in Beijing for individual pollutants and pollutant sources to individual members of a cohort. Issues considered in selecting specific monitoring data or new monitoring campaigns include: needed spatial resolution, exposure measurement error and its impact on health effect estimates, spatial alignment and compatibility with the cohort, and feasibility and expense. Sources of existing data largely include administrative monitoring data, predictions from air dispersion or chemical transport models and remote sensing (specifically satellite) data. New air monitoring campaigns include additional fixed site monitoring, snapshot monitoring, passive badge or micro-sensor saturation monitoring and mobile monitoring, as well as combinations of these. Each of these has relative advantages and disadvantages. It is concluded that a campaign in Beijing that at least includes a mobile monitoring component, when coupled with currently available spatio-temporal modeling methods, should be strongly considered. Such a campaign is economical and capable of providing the desired fine-scale spatial resolution for pollutants and sources. PMID:29244738

  18. Minimum current principle and variational method in theory of space charge limited flow

    NASA Astrophysics Data System (ADS)

    Rokhlenko, A.

    2015-10-01

    In spirit of the principle of least action, which means that when a perturbation is applied to a physical system, its reaction is such that it modifies its state to "agree" with the perturbation by "minimal" change of its initial state. In particular, the electron field emission should produce the minimum current consistent with boundary conditions. It can be found theoretically by solving corresponding equations using different techniques. We apply here the variational method for the current calculation, which can be quite effective even when involving a short set of trial functions. The approach to a better result can be monitored by the total current that should decrease when we on the right track. Here, we present only an illustration for simple geometries of devices with the electron flow. The development of these methods can be useful when the emitter and/or anode shapes make difficult the use of standard approaches. Though direct numerical calculations including particle-in-cell technique are very effective, but theoretical calculations can provide an important insight for understanding general features of flow formation and even sometimes be realized by simpler routines.

  19. Monitoring and Managing Fatigue in Basketball

    PubMed Central

    Edwards, Toby; Spiteri, Tania; Piggott, Benjamin; Bonhotal, Joshua; Joyce, Christopher

    2018-01-01

    The sport of basketball exposes athletes to frequent high intensity movements including sprinting, jumping, accelerations, decelerations and changes of direction during training and competition which can lead to acute and accumulated chronic fatigue. Fatigue may affect the ability of the athlete to perform over the course of a lengthy season. The ability of practitioners to quantify the workload and subsequent fatigue in basketball athletes in order to monitor and manage fatigue levels may be beneficial in maintaining high levels of performance and preventing unfavorable physical and physiological training adaptations. There is currently limited research quantifying training or competition workload outside of time motion analysis in basketball. In addition, systematic research investigating methods to monitor and manage athlete fatigue in basketball throughout a season is scarce. To effectively optimize and maintain peak training and playing performance throughout a basketball season, potential workload and fatigue monitoring strategies need to be discussed. PMID:29910323

  20. Understanding user needs for carbon monitoring information

    NASA Astrophysics Data System (ADS)

    Duren, R. M.; Macauley, M.; Gurney, K. R.; Saatchi, S. S.; Woodall, C. W.; Larsen, K.; Reidmiller, D.; Hockstad, L.; Weitz, M.; Croes, B.; Down, A.; West, T.; Mercury, M.

    2015-12-01

    The objectives of the Understanding User Needs project for NASA's Carbon Monitoring System (CMS) program are to: 1) engage the user community and identify needs for policy-relevant carbon monitoring information, 2) evaluate current and planned CMS data products with regard to their value for decision making, and 3) explore alternative methods for visualizing and communicating carbon monitoring information and associated uncertainties to decision makers and other stakeholders. To meet these objectives and help establish a sustained link between science and decision-making we have established a multi-disciplinary team that combines expertise in carbon-cycle science, engineering, economics, and carbon management and policy. We will present preliminary findings regarding emerging themes and needs for carbon information that may warrant increased attention by the science community. We will also demonstrate a new web-based tool that offers a common framework for facilitating user evaluation of carbon data products from multiple CMS projects.

  1. Monitoring Telluric Water Absorption with CAMAL

    NASA Astrophysics Data System (ADS)

    Baker, Ashley; Blake, Cullen; Sliski, David

    2017-01-01

    Ground-based observations are severely limited by telluric water vapor absorption features, which are highly variable in time and significantly complicate both spectroscopy and photometry in the near-infrared (NIR). To achieve the stability required to study Earth-sized exoplanets, monitoring the precipitable water vapor (PWV) becomes necessary to mitigate the impact of telluric lines on radial velocity measurements and transit light curves. To address this issue, we present the Camera for the Automatic Monitoring of Atmospheric Lines (CAMAL), a stand-alone, inexpensive 6-inch aperture telescope dedicated to measuring PWV at the Whipple Observatory. CAMAL utilizes three NIR narrowband filters to trace the amount of atmospheric water vapor affecting simultaneous observations with the MINiature Exoplanet Radial Velocity Array (MINERVA) and MINERVA-Red telescopes. We present the current design of CAMAL, discuss our calibration methods, and show PWV measurements taken with CAMAL compared to those of a nearby GPS water vapor monitor.

  2. Analysis of Circadian Leaf Movements.

    PubMed

    Müller, Niels A; Jiménez-Gómez, José M

    2016-01-01

    The circadian clock is a molecular timekeeper that controls a wide variety of biological processes. In plants, clock outputs range from the molecular level, with rhythmic gene expression and metabolite content, to physiological processes such as stomatal conductance or leaf movements. Any of these outputs can be used as markers to monitor the state of the circadian clock. In the model plant Arabidopsis thaliana, much of the current knowledge about the clock has been gained from time course experiments profiling expression of endogenous genes or reporter constructs regulated by the circadian clock. Since these methods require labor-intensive sample preparation or transformation, monitoring leaf movements is an interesting alternative, especially in non-model species and for natural variation studies. Technological improvements both in digital photography and image analysis allow cheap and easy monitoring of circadian leaf movements. In this chapter we present a protocol that uses an autonomous point and shoot camera and free software to monitor circadian leaf movements in tomato.

  3. Eddy-current testing of fatigue degradation upon contact fatigue loading of gas powder laser clad NiCrBSi-Cr3C2 composite coating

    NASA Astrophysics Data System (ADS)

    Savrai, R. A.; Makarov, A. V.; Gorkunov, E. S.; Soboleva, N. N.; Kogan, L. Kh.; Malygina, I. Yu.; Osintseva, A. L.; Davydova, N. A.

    2017-12-01

    The possibilities of the eddy-current method for testing the fatigue degradation under contact loading of gas powder laser clad NiCrBSi-Cr3C2 composite coating with 15 wt.% of Cr3C2 additive have been investigated. It is shown that the eddy-current testing of the fatigue degradation under contact loading of the NiCrBSi-15%Cr3C2 composite coating can be performed at high excitation frequencies 72-120 kHz of the eddy-current transducer. At that, the dependences of the eddy-current instrument readings on the number of loading cycles have both downward and upward branches, with the boundary between the branches being 3×105 cycles in the given loading conditions. This is caused, on the one hand, by cracking, and, on the other hand, by cohesive spalling and compaction of the composite coating, which affect oppositely the material resistivity and, correspondingly, the eddy-current instrument readings. The downward branch can be used to monitor the processes of crack formation and growth, the upward branch - to monitor the degree of cohesive spalling, while taking into account in the testing methodology an ambiguous character of the dependences of the eddy-current instrument readings on the number of loading cycles.

  4. In-line Fourier-transform infrared spectroscopy as a versatile process analytical technology for preparative protein chromatography.

    PubMed

    Großhans, Steffen; Rüdt, Matthias; Sanden, Adrian; Brestrich, Nina; Morgenstern, Josefine; Heissler, Stefan; Hubbuch, Jürgen

    2018-04-27

    Fourier-transform infrared spectroscopy (FTIR) is a well-established spectroscopic method in the analysis of small molecules and protein secondary structure. However, FTIR is not commonly applied for in-line monitoring of protein chromatography. Here, the potential of in-line FTIR as a process analytical technology (PAT) in downstream processing was investigated in three case studies addressing the limits of currently applied spectroscopic PAT methods. A first case study exploited the secondary structural differences of monoclonal antibodies (mAbs) and lysozyme to selectively quantify the two proteins with partial least squares regression (PLS) giving root mean square errors of cross validation (RMSECV) of 2.42 g/l and 1.67 g/l, respectively. The corresponding Q 2 values are 0.92 and, respectively, 0.99, indicating robust models in the calibration range. Second, a process separating lysozyme and PEGylated lysozyme species was monitored giving an estimate of the PEGylation degree of currently eluting species with RMSECV of 2.35 g/l for lysozyme and 1.24 g/l for PEG with Q 2 of 0.96 and 0.94, respectively. Finally, Triton X-100 was added to a feed of lysozyme as a typical process-related impurity. It was shown that the species could be selectively quantified from the FTIR 3D field without PLS calibration. In summary, the proposed PAT tool has the potential to be used as a versatile option for monitoring protein chromatography. It may help to achieve a more complete implementation of the PAT initiative by mitigating limitations of currently used techniques. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Trends in Health Information Technology Safety: From Technology-Induced Errors to Current Approaches for Ensuring Technology Safety

    PubMed Central

    2013-01-01

    Objectives Health information technology (HIT) research findings suggested that new healthcare technologies could reduce some types of medical errors while at the same time introducing classes of medical errors (i.e., technology-induced errors). Technology-induced errors have their origins in HIT, and/or HIT contribute to their occurrence. The objective of this paper is to review current trends in the published literature on HIT safety. Methods A review and synthesis of the medical and life sciences literature focusing on the area of technology-induced error was conducted. Results There were four main trends in the literature on technology-induced error. The following areas were addressed in the literature: definitions of technology-induced errors; models, frameworks and evidence for understanding how technology-induced errors occur; a discussion of monitoring; and methods for preventing and learning about technology-induced errors. Conclusions The literature focusing on technology-induced errors continues to grow. Research has focused on the defining what an error is, models and frameworks used to understand these new types of errors, monitoring of such errors and methods that can be used to prevent these errors. More research will be needed to better understand and mitigate these types of errors. PMID:23882411

  6. Analysis of munitions constituents in groundwater using a field-portable GC-MS.

    PubMed

    Bednar, A J; Russell, A L; Hayes, C A; Jones, W T; Tackett, P; Splichal, D E; Georgian, T; Parker, L V; Kirgan, R A; MacMillan, D K

    2012-05-01

    The use of munitions constituents (MCs) at military installations can produce soil and groundwater contamination that requires periodic monitoring even after training or manufacturing activities have ceased. Traditional groundwater monitoring methods require large volumes of aqueous samples (e.g., 2-4 L) to be shipped under chain of custody, to fixed laboratories for analysis. The samples must also be packed on ice and shielded from light to minimize degradation that may occur during transport and storage. The laboratory's turn-around time for sample analysis and reporting can be as long as 45 d. This process hinders the reporting of data to customers in a timely manner; yields data that are not necessarily representative of current site conditions owing to the lag time between sample collection and reporting; and incurs significant shipping costs for samples. The current work compares a field portable Gas Chromatograph-Mass Spectrometer (GC-MS) for analysis of MCs on-site with traditional laboratory-based analysis using High Performance Liquid Chromatography with UV absorption detection. The field method provides near real-time (within ~1 h of sampling) concentrations of MCs in groundwater samples. Mass spectrometry provides reliable confirmation of MCs and a means to identify unknown compounds that are potential false positives for methods with UV and other non-selective detectors. Published by Elsevier Ltd.

  7. Predictors of severe trunk postures among short-haul truck drivers during non-driving tasks: an exploratory investigation involving video-assessment and driver behavioural self-monitoring.

    PubMed

    Olson, R; Hahn, D I; Buckert, A

    2009-06-01

    Short-haul truck (lorry) drivers are particularly vulnerable to back pain and injury due to exposure to whole body vibration, prolonged sitting and demanding material handling tasks. The current project reports the results of video-based assessments (711 stops) and driver behavioural self-monitoring (BSM) (385 stops) of injury hazards during non-driving work. Participants (n = 3) worked in a trailer fitted with a camera system during baseline and BSM phases. Descriptive analyses showed that challenging customer environments and non-standard ingress/egress were prevalent. Statistical modelling of video-assessment results showed that each instance of manual material handling increased the predicted mean for severe trunk postures by 7%, while customer use of a forklift, moving standard pallets and moving non-standard pallets decreased predicted means by 12%, 20% and 22% respectively. Video and BSM comparisons showed that drivers were accurate at self-monitoring frequent environmental conditions, but less accurate at monitoring trunk postures and rare work events. The current study identified four predictors of severe trunk postures that can be modified to reduce risk of injury among truck drivers and showed that workers can produce reliable self-assessment data with BSM methods for frequent and easily discriminated events environmental.

  8. Current remote sensing approaches to monitoring forest degradation in support of countries measurement, reporting and verification (MRV) systems for REDD.

    PubMed

    Mitchell, Anthea L; Rosenqvist, Ake; Mora, Brice

    2017-12-01

    Forest degradation is a global phenomenon and while being an important indicator and precursor to further forest loss, carbon emissions due to degradation should also be accounted for in national reporting within the frame of UN REDD+. At regional to country scales, methods have been progressively developed to detect and map forest degradation, with these based on multi-resolution optical, synthetic aperture radar (SAR) and/or LiDAR data. However, there is no one single method that can be applied to monitor forest degradation, largely due to the specific nature of the degradation type or process and the timeframe over which it is observed. The review assesses two main approaches to monitoring forest degradation: first, where detection is indicated by a change in canopy cover or proxies, and second, the quantification of loss (or gain) in above ground biomass (AGB). The discussion only considers degradation that has a visible impact on the forest canopy and is thus detectable by remote sensing. The first approach encompasses methods that characterise the type of degradation and track disturbance, detect gaps in, and fragmentation of, the forest canopy, and proxies that provide evidence of forestry activity. Progress in these topics has seen the extension of methods to higher resolution (both spatial and temporal) data to better capture the disturbance signal, distinguish degraded and intact forest, and monitor regrowth. Improvements in the reliability of mapping methods are anticipated by SAR-optical data fusion and use of very high resolution data. The second approach exploits EO sensors with known sensitivity to forest structure and biomass and discusses monitoring efforts using repeat LiDAR and SAR data. There has been progress in the capacity to discriminate forest age and growth stage using data fusion methods and LiDAR height metrics. Interferometric SAR and LiDAR have found new application in linking forest structure change to degradation in tropical forests. Estimates of AGB change have been demonstrated at national level using SAR and LiDAR-assisted approaches. Future improvements are anticipated with the availability of next generation LiDAR sensors. Improved access to relevant satellite data and best available methods are key to operational forest degradation monitoring. Countries will need to prioritise their monitoring efforts depending on the significance of the degradation, balanced against available resources. A better understanding of the drivers and impacts of degradation will help guide monitoring and restoration efforts. Ultimately we want to restore ecosystem service and function in degraded forests before the change is irreversible.

  9. An optimized rapid bisulfite conversion method with high recovery of cell-free DNA.

    PubMed

    Yi, Shaohua; Long, Fei; Cheng, Juanbo; Huang, Daixin

    2017-12-19

    Methylation analysis of cell-free DNA is a encouraging tool for tumor diagnosis, monitoring and prognosis. Sensitivity of methylation analysis is a very important matter due to the tiny amounts of cell-free DNA available in plasma. Most current methods of DNA methylation analysis are based on the difference of bisulfite-mediated deamination of cytosine between cytosine and 5-methylcytosine. However, the recovery of bisulfite-converted DNA based on current methods is very poor for the methylation analysis of cell-free DNA. We optimized a rapid method for the crucial steps of bisulfite conversion with high recovery of cell-free DNA. A rapid deamination step and alkaline desulfonation was combined with the purification of DNA on a silica column. The conversion efficiency and recovery of bisulfite-treated DNA was investigated by the droplet digital PCR. The optimization of the reaction results in complete cytosine conversion in 30 min at 70 °C and about 65% of recovery of bisulfite-treated cell-free DNA, which is higher than current methods. The method allows high recovery from low levels of bisulfite-treated cell-free DNA, enhancing the analysis sensitivity of methylation detection from cell-free DNA.

  10. Expansion of Microbial Monitoring Capabilities on the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Khodadad, Christina L.; Oubre, Cherie; Castro, Victoria; Flint, Stephanie; Melendez, Orlando; Ott, C. Mark; Roman, Monsi

    2017-01-01

    Microbial monitoring is one of the tools that the National Aeronautics and Space Administration (NASA) uses on the International Space Station (ISS) to help maintain crew health and safety. In combination with regular housekeeping and disinfection when needed, microbial monitoring provides important information to the crew about the quality of the environment. Rotation of astronauts, equipment, and cargo on the ISS can affect the microbial load in the air, surfaces, and water. The current ISS microbial monitoring methods are focused on culture-based enumeration during flight and require a significant amount of crew time as well as long incubation periods of up to 5 days there by proliferating potential pathogens. In addition, the samples require return to Earth for complete identification of the microorganisms cultivated. Although the current approach assess the quality of the ISS environment, molecular technology offers faster turn-around of information particularly beneficial in an off-nominal situation. In 2011, subject matter experts from industry and academia recommended implementation of molecular-based technologies such as quantitative real-time polymerase chain reaction (qPCR) for evaluation to replace current, culture-based technologies. The RAZOR EX (BioFire Defense, Inc, Salt Lake City, UT) a ruggedized, compact, COTS (commercial off the shelf) qPCR instrument was tested, evaluated and selected in the 2 X 2015 JSC rapid flight hardware demonstration initiative as part of the Water Monitoring Suite. RAZOR EX was launched to ISS on SpaceX-9 in July 2016 to evaluate the precision and accuracy of the hardware by testing various concentrations of DNA in microgravity compared to ground controls. Flight testing was completed between September 2016 and March 2017. Data presented will detail the hardware performance of flight testing results compared to ground controls. Future goals include additional operational ground-based testing and assay development to determine if this technology can meet spaceflight microbial monitoring requirements.

  11. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

    PubMed

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2015-09-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

  12. Role of Therapeutic Drug Monitoring of Voriconazole in the Treatment of Invasive Fungal Infections

    PubMed Central

    Kuo, I fan; Ensom, Mary H H

    2009-01-01

    Background: Voriconazole is a broad-spectrum, second-generation triazole antifungal agent with demonstrated efficacy in the treatment of invasive fungal infections caused by Aspergillus spp. and Candida spp. Given the characteristically poor prognosis of patients with invasive fungal infections and the protracted duration of treatment required, therapeutic monitoring of voriconazole is, in theory, an attractive method to optimize antifungal therapy. Objective: To determine the utility of therapeutic drug monitoring for voriconazole. Methods: A previously published decision-making algorithm was used to assess the currently available literature on therapeutic drug monitoring of voriconazole. Results: Several analytical methods can be used to quantify plasma or serum concentrations of voriconazole. Reasons for therapeutic monitoring of this drug include wide variability both within and between individuals secondary to drug properties, drug–drug interactions, and disease states. Furthermore, voriconazole follows nonlinear pharmacokinetics with saturable hepatic clearance. Another potential factor in favour of therapeutic drug monitoring for voriconazole is genetic polymorphism of CYP2C19, whereby patients who are homozygous for poor metabolism (about 19% of non-Indian Asians) can have 4-fold greater exposure to voriconazole. The concentrations of this drug are also greater in patients with hepatic impairment. Drug–drug interactions with other substrates of CYP2C9, CYP2C19, and CYP3A4 can also alter voriconazole concentrations. However, the correlations between plasma concentrations of voriconazole and its efficacy and toxicity are not well defined. Although lower and upper target thresholds of 0.25–2 mg/L and 4–6 mg/L, respectively, have been suggested, studies to date have not been appropriately designed or powered to reveal any definitive association. Conclusions: Routine therapeutic drug monitoring of voriconazole is not recommended except in certain circumstances, such as lack of response to therapy or evidence of toxicity, in which case selective monitoring of voriconazole concentrations may be of clinical utility. PMID:22478935

  13. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF SYNTHETIC MUSK COMPOUNDS FROM FISH TISSUES WITH MEASUREMENT BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY WITH SELECTED-ION MONITORING

    EPA Science Inventory

    Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues ...

  14. Semiochemical sabotage: behavioral chemicals for protection of western conifers from bark beetles

    Treesearch

    Nancy. E. Gillette; A. Steve Munson

    2009-01-01

    The discovery and elucidation of volatile behavioral chemicals used by bark beetles to locate hosts and mates has revealed a rich potential for humans to sabotage beetle host-finding and reproduction. Here, we present a description of currently available semiochemical methods for use in monitoring and controlling bark beetle pests in western conifer forests. Delivery...

  15. CURRENT AND FUTURE IN SITU TREATMENT TECHNIQUES FOR THE REMEDIATION OF HAZARDOUS SUBSTANCES IN SOIL, SEDIMENTS, AND GROUNDWATER

    EPA Science Inventory

    This is a presentation that will be given at the NATO Advanced Research Workshop on "Viable Methods of Soil and Water Pollution Monitoring, Protection, and Remediation" in Krakow, Poland on June 27 - July 1, 2005. The U.S. EPA Office of Research and Development (ORD) co...

  16. Detection of viable Cyptosporidium parvum in soil by reverse transcription real time PCR targeting hsp70 mRNA

    EPA Science Inventory

    Extraction of high-quality mRNA from Cryptosporidium parvum is a key step in PCR detection of viable oocysts in environmental samples. Current methods for monitoring oocysts are limited to water samples; therefore, the goal of this study was to develop a rapid and sensitive proce...

  17. Noninvasive vacuum integrity tests on fast warm-up traveling-wave tubes

    NASA Astrophysics Data System (ADS)

    Dallos, A.; Carignan, R. G.

    1989-04-01

    A method of tube vacuum monitoring that uses the tube's existing internal electrodes as an ion gage is discussed. This method has been refined using present-day instrumentation and has proved to be a precise, simple, and fast method of tube vacuum measurement. The method is noninvasive due to operation of the cathode at low temperature, which minimizes pumping or outgassing. Because of the low current levels to be measured, anode insulator leakage must be low, and the leads must be properly shielded to minimize charging effects. A description of the method, instrumentation used, limitations, and data showing results over a period of 600 days are presented.

  18. Feasibility Study of a Rotorcraft Health and Usage Monitoring System ( HUMS): Usage and Structural Life Monitoring Evaluation

    NASA Technical Reports Server (NTRS)

    Dickson, B.; Cronkhite, J.; Bielefeld, S.; Killian, L.; Hayden, R.

    1996-01-01

    The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FLS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques. The data that was used for the evaluation of the usage monitoring techniques was collected under an independent HUMS Flight trial program, using a commercially available HUMS and data recording system. The usage data collect from the HUMS trial aircraft was analyzed off-line using PC-based software that included the FCR and FLS techniques. In the future, if the technique prove feasible, usage monitoring would be incorporated into the onboard HUMS.

  19. Some insights on grassland health assessment based on remote sensing.

    PubMed

    Xu, Dandan; Guo, Xulin

    2015-01-29

    Grassland ecosystem is one of the largest ecosystems, which naturally occurs on all continents excluding Antarctica and provides both ecological and economic functions. The deterioration of natural grassland has been attracting many grassland researchers to monitor the grassland condition and dynamics for decades. Remote sensing techniques, which are advanced in dealing with the scale constraints of ecological research and provide temporal information, become a powerful approach of grassland ecosystem monitoring. So far, grassland health monitoring studies have mostly focused on different areas, for example, productivity evaluation, classification, vegetation dynamics, livestock carrying capacity, grazing intensity, natural disaster detecting, fire, climate change, coverage assessment and soil erosion. However, the grassland ecosystem is a complex system which is formed by soil, vegetation, wildlife and atmosphere. Thus, it is time to consider the grassland ecosystem as an entity synthetically and establish an integrated grassland health monitoring system to combine different aspects of the complex grassland ecosystem. In this review, current grassland health monitoring methods, including rangeland health assessment, ecosystem health assessment and grassland monitoring by remote sensing from different aspects, are discussed along with the future directions of grassland health assessment.

  20. Some Insights on Grassland Health Assessment Based on Remote Sensing

    PubMed Central

    Xu, Dandan; Guo, Xulin

    2015-01-01

    Grassland ecosystem is one of the largest ecosystems, which naturally occurs on all continents excluding Antarctica and provides both ecological and economic functions. The deterioration of natural grassland has been attracting many grassland researchers to monitor the grassland condition and dynamics for decades. Remote sensing techniques, which are advanced in dealing with the scale constraints of ecological research and provide temporal information, become a powerful approach of grassland ecosystem monitoring. So far, grassland health monitoring studies have mostly focused on different areas, for example, productivity evaluation, classification, vegetation dynamics, livestock carrying capacity, grazing intensity, natural disaster detecting, fire, climate change, coverage assessment and soil erosion. However, the grassland ecosystem is a complex system which is formed by soil, vegetation, wildlife and atmosphere. Thus, it is time to consider the grassland ecosystem as an entity synthetically and establish an integrated grassland health monitoring system to combine different aspects of the complex grassland ecosystem. In this review, current grassland health monitoring methods, including rangeland health assessment, ecosystem health assessment and grassland monitoring by remote sensing from different aspects, are discussed along with the future directions of grassland health assessment. PMID:25643060

Top