Sample records for current performance levels

  1. Systems, methods and computer-readable media for modeling cell performance fade of rechargeable electrochemical devices

    DOEpatents

    Gering, Kevin L

    2013-08-27

    A system includes an electrochemical cell, monitoring hardware, and a computing system. The monitoring hardware periodically samples performance characteristics of the electrochemical cell. The computing system determines cell information from the performance characteristics of the electrochemical cell. The computing system also develops a mechanistic level model of the electrochemical cell to determine performance fade characteristics of the electrochemical cell and analyzing the mechanistic level model to estimate performance fade characteristics over aging of a similar electrochemical cell. The mechanistic level model uses first constant-current pulses applied to the electrochemical cell at a first aging period and at three or more current values bracketing a first exchange current density. The mechanistic level model also is based on second constant-current pulses applied to the electrochemical cell at a second aging period and at three or more current values bracketing the second exchange current density.

  2. Which level of competence and performance is expected? A survey among European employers of public health professionals.

    PubMed

    Vukovic, Dejana; Bjegovic-Mikanovic, Vesna; Otok, Robert; Czabanowska, Katarzyna; Nikolic, Zeljka; Laaser, Ulrich

    2014-02-01

    To explore largely unknown experience and expectations of European employers of public health professionals with regard to competences required to perform in the best way for the public health. A survey targeting employers in Europe was carried out September 2011–October 2012. The web-based questionnaire on public health competences and expected performance levels was returned by 63 organisations out of 109 contacted (57.8 %) as provided by Schools and Departments of Public Health (SDPH) in 30 European countries. The assessment of the current and desired levels of performance did not show significant differences between employer categories. However, current and desired levels across all employers differ significantly (p < 0.001), varying around a difference of one rank of a five-point scale. On the other hand, SDPH rank the exit qualifications of their graduates with one exception (presumed competences in preparedness for public health emergencies) higher than the current performance level as determined by employers, i.e. closer to their expectations. SDPH should reconsider priorities and question their estimate of exit qualifications in close contact with potential employers of their graduates.

  3. Evaluation of Fatigue Behavior and Surface Characteristics of Aluminum Alloy 2024 T6 After Electric Discharge Machining

    NASA Astrophysics Data System (ADS)

    Mehmood, Shahid; Shah, Masood; Pasha, Riffat Asim; Sultan, Amir

    2017-10-01

    The effect of electric discharge machining (EDM) on surface quality and consequently on the fatigue performance of Al 2024 T6 is investigated. Five levels of discharge current are analyzed, while all other electrical and nonelectrical parameters are kept constant. At each discharge current level, dog-bone specimens are machined by generating a peripheral notch at the center. The fatigue tests are performed on four-point rotating bending machine at room temperature. For comparison purposes, fatigue tests are also performed on the conventionally machined specimens. Linearized SN curves for 95% failure probability and with four different confidence levels (75, 90, 95 and 99%) are plotted for each discharge current level as well as for conventionally machined specimens. These plots show that the electric discharge machined (EDMed) specimens give inferior fatigue behavior as compared to conventionally machined specimen. Moreover, discharge current inversely affects the fatigue life, and this influence is highly pronounced at lower stresses. The EDMed surfaces are characterized by surface properties that could be responsible for change in fatigue life such as surface morphology, surface roughness, white layer thickness, microhardness and residual stresses. It is found that all these surface properties are affected by changing discharge current level. However, change in fatigue life by discharge current could not be associated independently to any single surface property.

  4. Performance evaluation of a modular detector unit for X-ray computed tomography.

    PubMed

    Guo, Zhe; Tang, Zhiwei; Wang, Xinzeng; Deng, Mingliang; Hu, Guangshu; Zhang, Hui

    2013-04-18

    A research prototype CT scanner is currently under development in our lab. One of the key components in this project is the CT detector. This paper describes the design and performance evaluation of the modular CT detector unit for our proposed scanner. It consists of a Photodiode Array Assembly which captures irradiating X-ray photons and converts the energy into electrical current, and a mini Data Acquisition System which performs current integration and converts the analog signal into digital samples. The detector unit can be easily tiled together to form a CT detector. Experiments were conducted to characterize the detector performance both at the single unit level and system level. The noise level, linearity and uniformity of the proposed detector unit were reported and initial imaging studies were also presented which demonstrated the potential application of the proposed detector unit in actual CT scanners.

  5. Laboratory septic tank performance response to electrolytic stimulation.

    PubMed

    Zaveri, Rahul M; Flora, Joseph R V

    2002-11-01

    This research investigated the effects of electrolytic stimulation on the performance of two laboratory-scale septic tanks. The tanks were fed a synthetic solution that included cellulose, peptone trypticase, beef extract, and urea. After a baseline period with no passed current, currents ranging from 100 to 500 mA were passed through the electrodes. The chemical oxygen demand (COD) removal efficiency from the tanks improved when a current was passed, with higher removal efficiencies observed at higher levels of passed current. Hydrolytic reactions resulted in ammonia and phosphate levels in the tanks that were higher than the influent. At currents > 300 mA, these hydrolytic reactions were suppressed, resulting in phosphate levels similar to the influent and ammonia levels lower than the influent because of the settling of ammonia-containing components of the feed solution. A slight increase in nitrate levels was observed when a current was passed, indicating minimal stimulation of nitrification activity. Abiotic studies confirmed that the COD can be removed via electrolysis and the removal was proportional to the passed current. Under the conditions of this study, the primary benefit of electrolytic stimulation of the septic tank is enhanced COD removal.

  6. The performance of integrated transconductance amplifiers as variable current sources for bio-electric impedance measurements.

    PubMed

    Smith, D N

    1992-01-01

    Multiple applied current impedance measurement systems require numbers of current sources which operate simultaneously at the same frequency and within the same phase but at variable amplitudes. Investigations into the performance of some integrated operational transconductance amplifiers as variable current sources are described. Measurements of breakthrough, non-linearity and common-mode output levels for LM13600, NE5517 and CA3280 were carried out. The effects of such errors on the overall performance and stability of multiple current systems when driving floating loads are considered.

  7. NEXT Ion Thruster Performance Dispersion Analyses

    NASA Technical Reports Server (NTRS)

    Soulas, George C.; Patterson, Michael J.

    2008-01-01

    The NEXT ion thruster is a low specific mass, high performance thruster with a nominal throttling range of 0.5 to 7 kW. Numerous engineering model and one prototype model thrusters have been manufactured and tested. Of significant importance to propulsion system performance is thruster-to-thruster performance dispersions. This type of information can provide a bandwidth of expected performance variations both on a thruster and a component level. Knowledge of these dispersions can be used to more conservatively predict thruster service life capability and thruster performance for mission planning, facilitate future thruster performance comparisons, and verify power processor capabilities are compatible with the thruster design. This study compiles the test results of five engineering model thrusters and one flight-like thruster to determine unit-to-unit dispersions in thruster performance. Component level performance dispersion analyses will include discharge chamber voltages, currents, and losses; accelerator currents, electron backstreaming limits, and perveance limits; and neutralizer keeper and coupling voltages and the spot-to-plume mode transition flow rates. Thruster level performance dispersion analyses will include thrust efficiency.

  8. Blade design and performance analysis on the horizontal axis tidal current turbine for low water level channel

    NASA Astrophysics Data System (ADS)

    Chen, C. C.; Choi, Y. D.; Y Yoon, H.

    2013-12-01

    Most tidal current turbine design are focused on middle and large scale for deep sea, less attention was paid in low water level channel, such as the region around the islands, coastal seas and rivers. This study aims to develop a horizontal axis tidal current turbine rotor blade which is applicable to low water level island region in southwest of Korea. The blade design is made by using BEMT(blade element momentum theory). The section airfoil profile of NACA63-415 is used, which shows good performance of lift coefficient and drag coefficient. Power coefficient, pressure and velocity distributions are investigated according to TSR by CFD analysis.

  9. Fast charge implications: Pack and cell analysis and comparison

    NASA Astrophysics Data System (ADS)

    Tanim, Tanvir R.; Shirk, Matthew G.; Bewley, Randy L.; Dufek, Eric J.; Liaw, Bor Yann

    2018-03-01

    This study investigates the effect of 50-kW (about 2C) direct current fast charging on a full-size battery electric vehicle's battery pack in comparison to a pack exclusively charged at 3.3 kW, which is the common alternating current Level 2 charging power level. Comparable scaled charging protocols are also independently applied to individual cells at three different temperatures, 20 °C, 30 °C, and 40 °C, to perform a comparative analysis with the packs. Dominant cell-level aging modes were identified through incremental capacity analysis and compared with full packs to gain a clear understanding of additional key factors that affect pack aging. While the cell-level study showed a minor impact on performance due to direct current fast charging, the packs showed a significantly higher rate of capacity fade under similar charging protocols. This indicates that pack-level aging cannot be directly extrapolated from cell evaluation. Delayed fast charging, completing shortly before discharge, was found to have less of an impact on battery degradation than conventional alternating current Level 2 charging.

  10. Diagnostic Tools for Performance Evaluation of Innovative In-Situ Remediation Technologies at Chlorinated Solvent-Contaminated Sites

    DTIC Science & Technology

    2011-07-01

    to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT...these innovative methods with conventional diagnostic tools that are currently used for assessing bioremediation performance. 132 Rula Deeb (510) 596...conventional diagnostic tools that are currently used for assessing bioremediation performance. DEMONSTRATION RESULTS 3-D multi-level systems

  11. Motor current signature analysis for gearbox condition monitoring under transient speeds using wavelet analysis and dual-level time synchronous averaging

    NASA Astrophysics Data System (ADS)

    Bravo-Imaz, Inaki; Davari Ardakani, Hossein; Liu, Zongchang; García-Arribas, Alfredo; Arnaiz, Aitor; Lee, Jay

    2017-09-01

    This paper focuses on analyzing motor current signature for fault diagnosis of gearboxes operating under transient speed regimes. Two different strategies are evaluated, extensively tested and compared to analyze the motor current signature in order to implement a condition monitoring system for gearboxes in industrial machinery. A specially designed test bench is used, thoroughly monitored to fully characterize the experiments, in which gears in different health status are tested. The measured signals are analyzed using discrete wavelet decomposition, in different decomposition levels using a range of mother wavelets. Moreover, a dual-level time synchronous averaging analysis is performed on the same signal to compare the performance of the two methods. From both analyses, the relevant features of the signals are extracted and cataloged using a self-organizing map, which allows for an easy detection and classification of the diverse health states of the gears. The results demonstrate the effectiveness of both methods for diagnosing gearbox faults. A slightly better performance was observed for dual-level time synchronous averaging method. Based on the obtained results, the proposed methods can used as effective and reliable condition monitoring procedures for gearbox condition monitoring using only motor current signature.

  12. The impact of manufacturing complexity drivers on performance-a preliminary study

    NASA Astrophysics Data System (ADS)

    Huah Leang, Suh; Mahmood, Wan Hasrulnizzam Wan; Rahman, Muhamad Arfauz A.

    2018-03-01

    Manufacturing systems, in pursuit of cost, time and flexibility optimisation are becoming more and more complex, exhibiting a dynamic and nonlinear behaviour. Unpredictability is a distinct characteristic of such behaviour and effects production planning significantly. Therefore, this study was undertaken to investigate the priority level and current achievement of manufacturing performance in Malaysia’s manufacturing industry and the complexity drivers on manufacturing productivity performance. The results showed that Malaysia’s manufacturing industry prioritised product quality and they managed to achieve a good on time delivery performance. However, for other manufacturing performance, there was a difference where the current achievement of manufacturing performances in Malaysia’s manufacturing industry is slightly lower than the priority given to them. The strong correlation of significant value for priority status was observed between efficient production levelling (finished goods) and finish product management while the strong correlation of significant value for current achievement was minimised the number of workstation and factory transportation system. This indicates that complexity drivers have an impact towards manufacturing performance. Consequently, it is necessary to identify complexity drivers to achieve well manufacturing performance.

  13. On-Orbit Performance Degradation of the International Space Station P6 Photovoltaic Arrays

    NASA Technical Reports Server (NTRS)

    Kerslake, Thomas W.; Gustafson, Eric D.

    2003-01-01

    This paper discusses the on-orbit performance and performance degradation of the International Space Station P6 solar array wings (SAWs) from the period of December 2000 through February 2003. Data selection considerations and data reduction methods are reviewed along with the approach for calculating array performance degradation based on measured string shunt current levels. Measured degradation rates are compared with those predicted by the computational tool SPACE and prior degradation rates measured with the same SAW technology on the Mir space station. Initial results show that the measured SAW short-circuit current is degrading 0.2 to 0.5 percent per year. This degradation rate is below the predicted rate of 0.8 percent per year and is well within the 3 percent estimated uncertainty in measured SAW current levels. General contributors to SAW degradation are briefly discussed.

  14. Performance of a low-power subsonic-arc-attachment arcjet thruster

    NASA Technical Reports Server (NTRS)

    Sankovic, John M.; Berns, Darren H.

    1993-01-01

    A subsonic-arc-attachment thruster design was scaled from a 30 kW 1960's vintage thruster to operate at nominally 3 kW. Performance measurements were obtained over a 1-4 kW power range using hydrogen as the propellant. Several modes of operation were identified and were characterized by varying degrees of voltage instability. A stability map was developed showing that the voltage oscillations were brought upon by elevated current or propellant levels. At a given specific energy level the specific impulse increased asymptotically with increased flow rates. Comparisons of performance were made between radial and tangential propellant injection. When the vortex flow was eliminated using radial injection, the operating voltages were lower at a given current, and the specific impulse and efficiency decreased. Tests were also conducted to determine the effects of background pressure on operation, and performance data were obtained at pressures of 0.047 Pa and 18 Pa. For a given specific energy level, the performance increased with a decrease in facility background pressure. Lowering the background pressure also caused a dramatic change in the voltage-current characteristic and the voltage stability, a phenomenon not previously reported with conventional supersonic-arc-attachment thrusters.

  15. Fractional Factorial Design Study on the Performance of GAC-Enhanced Electrocoagulation Process Involved in Color Removal from Dye Solutions.

    PubMed

    Secula, Marius Sebastian; Cretescu, Igor; Cagnon, Benoit; Manea, Liliana Rozemarie; Stan, Corneliu Sergiu; Breaban, Iuliana Gabriela

    2013-07-10

    The aim of this study was to determine the effects of main factors and interactions on the color removal performance from dye solutions using the electrocoagulation process enhanced by adsorption on Granular Activated Carbon (GAC). In this study, a mathematical approach was conducted using a two-level fractional factorial design ( FFD ) for a given dye solution. Three textile dyes: Acid Blue 74, Basic Red 1, and Reactive Black 5 were used. Experimental factors used and their respective levels were: current density (2.73 or 27.32 A/m²), initial pH of aqueous dye solution (3 or 9), electrocoagulation time (20 or 180 min), GAC dose (0.1 or 0.5 g/L), support electrolyte (2 or 50 mM), initial dye concentration (0.05 or 0.25 g/L) and current type (Direct Current- DC or Alternative Pulsed Current- APC ). GAC-enhanced electrocoagulation performance was analyzed statistically in terms of removal efficiency, electrical energy, and electrode material consumptions, using modeling polynomial equations. The statistical significance of GAC dose level on the performance of GAC enhanced electrocoagulation and the experimental conditions that favor the process operation of electrocoagulation in APC regime were determined. The local optimal experimental conditions were established using a multi-objective desirability function method.

  16. Current Hale ROA Voice and Control Communication Practices and Performance: White Paper

    NASA Technical Reports Server (NTRS)

    2007-01-01

    The objective of this white paper is to help achieve the ACCESS 5 goal by sharing the UNITE members knowledge of current HALE ROA communication systems with other ACCESS 5 participants so that all interested parties start from a common understanding as we begin the clarification of requirements for voice and C2 communication. This white paper is also intended to describe the point of departure for any future developments that need to be realized to achieve the long term ACCESS 5 goal. Although this white paper describes the current systems, the functional and performance requirements that are also being developed under ACCESS 5 may not require the same levels of functionality and performance as currently exist. The paper addresses the following: 1) A description of a typical current HALE ROA communications system, 2) HALE ROA communications systems performance metrics, 3) HALE ROA communications systems performance, and 5) A comparison of current HALE ROA communications systems with current regulations.

  17. Performance assessment in brain-computer interface-based augmentative and alternative communication

    PubMed Central

    2013-01-01

    A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this technology. This paper presents a review of the metrics that have been used to report performance of BCIs used for AAC from January 2005 to January 2012. We distinguish between Level 1 metrics used to report performance at the output of the BCI Control Module, which translates brain signals into logical control output, and Level 2 metrics at the Selection Enhancement Module, which translates logical control to semantic control. We recommend that: (1) the commensurate metrics Mutual Information or Information Transfer Rate (ITR) be used to report Level 1 BCI performance, as these metrics represent information throughput, which is of interest in BCIs for AAC; 2) the BCI-Utility metric be used to report Level 2 BCI performance, as it is capable of handling all current methods of improving BCI performance; (3) these metrics should be supplemented by information specific to each unique BCI configuration; and (4) studies involving Selection Enhancement Modules should report performance at both Level 1 and Level 2 in the BCI system. Following these recommendations will enable efficient comparison between both BCI Control and Selection Enhancement Modules, accelerating research and development of BCI-based AAC systems. PMID:23680020

  18. 34 CFR 361.89 - Enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... revisions until the DSU sustains satisfactory performance based on the current performance levels over a period of more than 1 year. (d) If the Secretary determines that a DSU with less than satisfactory... satisfactory level on the compliance indicators. (Approved by the Office of Management and Budget under control...

  19. Patriot Advanced Capability-3 Missile Segment Enhancement (PAC-3 MSE)

    DTIC Science & Technology

    2015-12-01

    Threshold Demonstrated Performance Current Estimate System Training Proficiency Level Soldiers (Operators, Maintainers, and Leaders) are able to...constructive training environments by using TADSS to conduct multi- level training for both operators and maintenance personnel. With the addition...0.0 Total 6037.0 6037.0 N/A 6276.9 6722.3 6722.3 6900.3 Current APB Cost Estimate Reference Army Cost Position dated February 28, 2014 Confidence Level

  20. Investigating gender violence in Jamaica.

    PubMed

    Spiring, Fred

    2014-01-01

    As Jamaica moves through implementation of their National Policy on Gender Equality and develops harassment legislation, this article attempts to investigate current levels and trends of gender-based violence in Jamaica. All analyses make use of existing data and data formats in developing performance indicators that illustrate the current state of gender violence in Jamaica. The analyses provide a baseline for the future assessment and comparison with internationally accepted gender-based violence indicators. All source data has been included to facilitate comparisons and discussions regarding related levels and trends of violence as well as addressing performance indicator effectiveness.

  1. The Relationship between Depression and College Academic Performance

    ERIC Educational Resources Information Center

    DeRoma, Virginia M.; Leach, John B.; Leverett, J. Patrick

    2009-01-01

    The current study examined the association between self-reported depressive symptomology and college academic performance. A significant, negative relationship was found between depression and academic performance. Furthermore, students presenting with moderate levels of depressive symptoms demonstrated lower performance within academic…

  2. The Effect of Cerebellar Transcranial Direct Current Stimulation on A Throwing Task Depends on Individual Level of Task Performance.

    PubMed

    Mizuguchi, Nobuaki; Katayama, Takashi; Kanosue, Kazuyuki

    2018-02-10

    The effect of cerebellar transcranial direct current stimulation (tDCS) on motor performance remains controversial. Some studies suggest that the effect of tDCS depends upon task-difficulty and individual level of task performance. Here, we investigated whether the effect of cerebellar tDCS on the motor performance depends upon the individual's level of performance. Twenty-four naïve participants practiced dart throwing while receiving a 2-mA cerebellar tDCS for 20 min under three stimulus conditions (anodal-, cathodal-, and sham-tDCS) on separate days with a double-blind, counter-balanced cross-over design. Task performance was assessed by measuring the distance between the center of the bull's eye and the dart's position. Although task performance tended to improve throughout the practice under all stimulus conditions, improvement within a given day was not significant as compared to the first no-stimulus block. In addition, improvement did not differ among stimulation conditions. However, the magnitude of improvement was associated with an individual's level of task performance only under cathodal tDCS condition (p < 0.05). This resulted in a significant performance improvement only for the sub-group of participants with lower performance levels as compared to that with sham-tDCS (p < 0.05). These findings suggest that the facilitation effect of cerebellar cathodal tDCS on motor skill learning of complex whole-body movements depends on the level of an individual's task performance. Thus, cerebellar tDCS would facilitate learning of a complex motor skill task only in a subset of individuals. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  3. Trial-to-trial fluctuations in attentional state and their relation to intelligence.

    PubMed

    Unsworth, Nash; McMillan, Brittany D

    2014-05-01

    Trial-to-trial fluctuations in attentional state while performing measures of intelligence were examined in the current study. Participants performed various measures of fluid and crystallized intelligence while also providing attentional state ratings prior to each trial. It was found that pre-trial attentional state ratings strongly predicted subsequent trial performance on the fluid intelligence measures, such that when participants rated their current attentional state as highly focused on the current task, performance tended to be high compared to when participants reported their current attentional state as being low and unfocused on the current task. Furthermore, overall attentional state ratings and variability in attentional state ratings were moderately correlated with overall levels of performance on the fluid intelligence measures. However, attentional state ratings did not predict performance on the measure of crystallized intelligence. These results suggest a strong link between variation in attention state and variation in fluid intelligence as postulated by a number of recent theories. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  4. DSS range delay calibrations: Current performance level

    NASA Technical Reports Server (NTRS)

    Spradlin, G. L.

    1976-01-01

    A means for evaluating Deep Space Station (DSS) range delay calibration performance was developed. Inconsistencies frequently noted in these data are resolved. Development of the DSS range delay data base is described. The data base is presented with comments regarding apparent discontinuities. Data regarding the exciter frequency dependence of the delay values are presented. The improvement observed in the consistency of current DSS range delay calibration data over the performance previously observed is noted.

  5. Performance, Stability, and Plume Characterization of the HERMeS Thruster with Boron Nitride Silica Composite Discharge Channel

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Huang, Wensheng; Gilland, James H.; Haag, Thomas W.; Mackey, Jonathan; Yim, John; Pinero, Luis; Williams, George; Peterson, Peter; Herman, Daniel

    2017-01-01

    NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.

  6. Investigating Student Choices in Performing Higher-Level Comprehension Tasks Using TED

    ERIC Educational Resources Information Center

    Bianchi, Francesca; Marenzi, Ivana

    2016-01-01

    The current paper describes a first experiment in the use of TED talks and open tagging exercises to train higher-level comprehension skills, and of automatic logging of the student's actions to investigate the student choices while performing analytical tasks. The experiment took advantage of an interactive learning platform--LearnWeb--that…

  7. How Non-Linearity and Grade-Level Differences Complicate the Validation of Observation Protocols

    ERIC Educational Resources Information Center

    Lazarev, Valeriy; Newman, Denis

    2013-01-01

    Teacher evaluation is currently a major policy issue at all levels of the K-12 system driven in large part by current US Department of Education requirements. The main objective of this study is to explore the patterns of relationship between observational scores and value-added measures of teacher performance in math classrooms and the variation…

  8. Steady state and transient simulation of anion exchange membrane fuel cells

    NASA Astrophysics Data System (ADS)

    Dekel, Dario R.; Rasin, Igal G.; Page, Miles; Brandon, Simon

    2018-01-01

    We present a new model for anion exchange membrane fuel cells. Validation against experimental polarization curve data is obtained for current densities ranging from zero to above 2 A cm-2. Experimental transient data is also successfully reproduced. The model is very flexible and can be used to explore the system's sensitivity to a wide range of material properties, cell design specifications, and operating parameters. We demonstrate the impact of gas inlet relative humidity (RH), operating current density, ionomer loading and ionomer ion exchange capacity (IEC) values on cell performance. In agreement with the literature, high air RH levels are shown to improve cell performance. At high current densities (>1 A cm-2) this effect is observed to be especially significant. Simulated hydration number distributions across the cell reveal the related critical dependence of cathode hydration on air RH and current density values. When exploring catalyst layer design, optimal intermediate ionomer loading values are demonstrated. The benefits of asymmetric (cathode versus anode) electrode design are revealed, showing enhanced performance using higher cathode IEC levels. Finally, electrochemical reaction profiles across the electrodes uncover inhomogeneous catalyst utilization. Specifically, at high current densities the cathodic reaction is confined to a narrow region near the membrane.

  9. C-5 Reliability Enhancement and Re-engining Program (C-5 RERP)

    DTIC Science & Technology

    2015-12-01

    Production Estimate Current APB Production Objective/Threshold Demonstrated Performance Current Estimate Time To Climb/Initial Level Off 837,000 lbs...RCR - Runway Condition Reading SDD - System Design and Development SL - Sea Level C-5 RERP December 2015 SAR March 23, 2016 16:10:28 UNCLASSIFIED 12...5.3 5.3 Acq O&M 0.0 0.0 -- 0.0 0.0 0.0 0.0 Total 7146.6 7135.7 N/A 6698.0 7694.1 7510.7 7066.6 Confidence Level Confidence Level of cost estimate

  10. Earth Observing-1 Advanced Imager Flight Performance Assessment: Investigating Dark Current Stability Over One-Half Orbit Period during the First 60 Days

    NASA Technical Reports Server (NTRS)

    Mendenhall, J. A.

    2001-01-01

    The stability of the EO-1 Advanced Land Imager dark current levels over the period of one-half orbit is investigated. A series of two-second dark current collections, over the course of 40 minutes, was performed during the first sixty days the instrument was in orbit. Analysis of this data indicates only two dark current reference periods, obtained entering and exiting eclipse, are required to remove ALI dark current offsets for 99.9% of the focal plane to within 1.5 digital numbers for any observation on the solar illuminated portion of the orbit.

  11. The effects of magnetic field in plume region on the performance of multi-cusped field thruster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Peng, E-mail: hupengemail@126.com; Liu, Hui, E-mail: thruster@126.com; Yu, Daren

    2015-10-15

    The performance characteristics of a Multi-cusped Field Thruster depending on the magnetic field in the plume region were investigated. Five magnetic field shielding rings were separately mounted near the exit of discharge channel to decrease the strength of magnetic field in the plume region in different levels, while the magnetic field in the upstream was well maintained. The test results show that the electron current increases with the decrease of magnetic field strength in the plume region, which gives rise to higher propellant utilization and lower current utilization. On the other hand, the stronger magnetic field in the plume regionmore » improves the performance at low voltages (high current mode) while lower magnetic field improves the performance at high voltages (low current mode). This work can provide some optimal design ideas of the magnetic strength in the plume region to improve the performance of thruster.« less

  12. Performance measures for public transit mobility management.

    DOT National Transportation Integrated Search

    2011-12-01

    "Mobility management is an innovative approach for managing and delivering coordinated public : transportation services that embraces the full family of public transit options. At a national level, there are : currently no industry recognized perform...

  13. 5 CFR 410.101 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... supports agency goals by improving organizational performance at any appropriate level in the agency, as... and performance objectives; (2) Improves an employee's current job performance; (3) Allows for..., United States Code. (i) Established contact hours are the number of academic credit hours assigned to a...

  14. The effect of segmented anodes on the performance and plume of a Hall thruster

    NASA Astrophysics Data System (ADS)

    Kieckhafer, Alexander W.

    Development of alternative propellants for Hall thruster operation is an active area of research. Xenon is the current propellant of choice for Hall thrusters, but can be costly in large thrusters and for extended test periods. Condensible propellants may offer an alternative to xenon, as they will not require costly active pumping to remove from a test facility, and may be less expensive to purchase. A method has been developed which uses segmented electrodes in the discharge channel of a Hall thruster to divert discharge current to and from the main anode and thus control the anode temperature. By placing a propellant reservoir in the anode, the evaporation rate, and hence, mass flow of propellant can be controlled. Segmented electrodes for thermal control of a Hall thruster represent a unique strategy of thruster design, and thus the performance of the thruster must be measured to determine the effect the electrodes have on the thruster. Furthermore, the source of any changes in thruster performance due to the adjustment of discharge current between the shims and the main anode must be characterized. A Hall thruster was designed and constructed with segmented electrodes. It was then tested at anode voltages between 300 and 400 V and mass flows between 4 and 6 mg/s, as well as 100%, 75%, 50%, 25%, and <5% of the discharge current on the shim electrodes. The level of current on the shims was adjusted by changing the shim voltage. At each operating point, the thruster performance, plume divergence, ion energy, and multiply charged ion fraction were measured. Thruster performance exhibited a small change with the level of discharge current on the shim electrodes. Thrust and specific impulse increased by as much as 6% and 7.7%, respectively, as discharge current was shifted from the main anode to the shims at constant anode voltage. Thruster efficiency did not change. Plume divergence was reduced by approximately 4 degrees of half-angle at high levels of current on the shims and at all combinations of mass flow and anode voltage. The fraction of singly charged xenon in the thruster plume varied between approximately 80% and 95% as the anode voltage and mass flow were changed, but did not show a significant change with shim current. Doubly and triply charged xenon made up the remainder of the ions detected. Ion energy exhibited a mixed behavior. The highest voltage present in the thruster largely dictated the most probable energy; either shim or anode voltage, depending on which was higher. The overall change in most probable ion energy was 20-30 eV, the majority of which took place while the shim voltage was higher than the anode voltage. The thrust, specific impulse, plume divergence, and ion energy all indicate that the thruster is capable of a higher performance output at high levels of discharge current on the shims. The lack of a change in efficiency and fraction of multiply charged ions indicate that the thruster can be operated at any level of current on the shims without detrimental effect, and thus a condensible propellant thruster can control the anode temperature without a decrease in efficiency or a change in the multiply charged ion fraction.

  15. Training Effects of Alternated and Pulsed Currents on the Quadriceps Muscles of Athletes.

    PubMed

    Oliveira, Pedro; Modesto, Karenina Arrais Guida; Bottaro, Martim; Babault, Nicolas; Durigan, João Luiz Quagliotti

    2018-05-22

    The aim of the study was to evaluate the effects of 6 weeks training with different neuromuscular electrical stimulation (NMES) currents (medium alternated and low-frequency pulsed current) on muscle architecture and neuromuscular performance of competitive athletes. A double-blind controlled and randomized experimental study was carried out with 33 athletes (22.2±2.6 yrs, 74.7±9.8 kg, 176.8±6.0 cm), divided into 3 groups: mid-frequency current (MF, n=12), pulsed current (PC, n=11) and the control group (CG, n=10). Quadriceps maximal voluntary peak torque (PT) and corresponding vastus lateralis electromyographic activity, evoked torque (PT-NMES), vastus lateralis muscle thickness, fascicle length, pennation angle, and level of discomfort were assessed before and after the interventions. NMES training was performed 3 times per week and consisted of 18 sessions, 15 min/session, 6 s duration in each contraction interspersed with 18 s rest. After the training period, muscle thickness increased in the MF and PC groups (p<0.05). PT-NMES increased only in the PC group (p<0.05). All currents produced similar levels of discomfort (p>0.05). Quadriceps NMES training applied through alternated or pulsed currents produced similar effects in architecture and neuromuscular performance in competitive athletes. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Characterization of Current Tower Cab Environments

    DOT National Transportation Integrated Search

    1977-11-01

    This report describes the general tower cab environment in terms of: (a) the evolution of the tower cab, current cab classification and staffing levels, and the basic flow of ATC data relevant to cab operations, (b) a breakdown of functions performed...

  17. Are we drunk yet? Motor versus cognitive cues of subjective intoxication.

    PubMed

    Celio, Mark A; Usala, Julie M; Lisman, Stephen A; Johansen, Gerard E; Vetter-O'Hagen, Courtney S; Spear, Linda P

    2014-02-01

    Perception of alcohol intoxication presumably plays an important role in guiding behavior during a current drinking episode. Yet, there has been surprisingly little investigation of what aspects associated with intoxication are used by individuals to attribute their level of intoxication. Building on recent laboratory-based findings, this study employed a complex field-based design to explore the relative contributions of motor performance versus cognitive performance-specifically executive control-on self-attributions of intoxication. Individuals recruited outside of bars (N = 280; mean age = 22; range: 18 to 32) completed a structured interview, self-report questionnaire, and neuropsychological testing battery, and provided a breath alcohol concentration (BrAC) sample. Results of a multiple linear regression analysis demonstrated that current level of subjective intoxication was associated with current alcohol-related stimulant effects, current sedative effects, and current BrAC. After controlling for the unique variance accounted for by these factors, subjective intoxication was better predicted by simple motor speed, as indexed by performance on the Finger Tapping Test, than by executive control, as indexed by performance on the Trail Making Test. These results-generated from data collected in a naturally occurring setting-support previous findings from a more traditional laboratory-based investigation, thus illustrating the iterative process of linking field methodology and controlled laboratory experimentation. Copyright © 2013 by the Research Society on Alcoholism.

  18. Optimization of Experimental Conditions of the Pulsed Current GTAW Parameters for Mechanical Properties of SDSS UNS S32760 Welds Based on the Taguchi Design Method

    NASA Astrophysics Data System (ADS)

    Yousefieh, M.; Shamanian, M.; Saatchi, A.

    2012-09-01

    Taguchi design method with L9 orthogonal array was implemented to optimize the pulsed current gas tungsten arc welding parameters for the hardness and the toughness of super duplex stainless steel (SDSS, UNS S32760) welds. In this regard, the hardness and the toughness were considered as performance characteristics. Pulse current, background current, % on time, and pulse frequency were chosen as main parameters. Each parameter was varied at three different levels. As a result of pooled analysis of variance, the pulse current is found to be the most significant factor for both the hardness and the toughness of SDSS welds by percentage contribution of 71.81 for hardness and 78.18 for toughness. The % on time (21.99%) and the background current (17.81%) had also the next most significant effect on the hardness and the toughness, respectively. The optimum conditions within the selected parameter values for hardness were found as the first level of pulse current (100 A), third level of background current (70 A), first level of % on time (40%), and first level of pulse frequency (1 Hz), while they were found as the second level of pulse current (120 A), second level of background current (60 A), second level of % on time (60%), and third level of pulse frequency (5 Hz) for toughness. The Taguchi method was found to be a promising tool to obtain the optimum conditions for such studies. Finally, in order to verify experimental results, confirmation tests were carried out at optimum working conditions. Under these conditions, there were good agreements between the predicted and the experimental results for the both hardness and toughness.

  19. Performance Characterization of the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) CCD Cameras

    NASA Technical Reports Server (NTRS)

    Joiner, Reyann; Kobayashi, Ken; Winebarger, Amy; Champey, Patrick

    2014-01-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument which is currently being developed by NASA's Marshall Space Flight Center (MSFC) and the National Astronomical Observatory of Japan (NAOJ). The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's Chromosphere to make measurements of the magnetic field in this region. In order to make accurate measurements of this effect, the performance characteristics of the three on-board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of no greater than 2 e(-)/DN, a noise level less than 25e(-), a dark current level which is less than 10e(-)/pixel/s, and a residual nonlinearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.

  20. The Relationships between Human Capital, Implicit Views of Intelligence, and Literacy Performance: Implications for the Obama Education Era

    ERIC Educational Resources Information Center

    Williams, Rihana S.; Ari, Omer; Dortch, Cedrick

    2011-01-01

    African American adolescents from families with low levels of human capital (i.e., caregiver level of education) are at risk for poor early adult outcomes. The current study examined the relationships among 48 African American high school students' literacy performance (e.g., reading and vocabulary), their implicit views of intelligence, their…

  1. The performance of cable braids and terminations to lightning induced transients

    NASA Technical Reports Server (NTRS)

    Crofts, David

    1991-01-01

    The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.

  2. 20 CFR 641.700 - What performance measures/indicators apply to SCSEP grantees?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... performance. There are currently eight performance measures, of which six are core indicators and two are additional indicators. Core indicators (defined in § 641.710) are subject to goal-setting and corrective action (described in § 641.720); that is, performance level goals for each core indicator must be agreed...

  3. Biased feedback in brain-computer interfaces.

    PubMed

    Barbero, Alvaro; Grosse-Wentrup, Moritz

    2010-07-27

    Even though feedback is considered to play an important role in learning how to operate a brain-computer interface (BCI), to date no significant influence of feedback design on BCI-performance has been reported in literature. In this work, we adapt a standard motor-imagery BCI-paradigm to study how BCI-performance is affected by biasing the belief subjects have on their level of control over the BCI system. Our findings indicate that subjects already capable of operating a BCI are impeded by inaccurate feedback, while subjects normally performing on or close to chance level may actually benefit from an incorrect belief on their performance level. Our results imply that optimal feedback design in BCIs should take into account a subject's current skill level.

  4. Swept-Ramp Detonation Initiation Performance in a High-Pressure Pulse Detonation Combustor

    DTIC Science & Technology

    2010-12-01

    conditions at sea level, but at elevated temperatures of 300–500°F in the combustor. The current work was motivated by a need to experimentally...The current work was motivated by a need to experimentally evaluate the detonation initiation performance of a PDC at elevated combustor pressures...High-Speed Propulsion Technologies (After [3]) .....................2 Figure 2. Stationary One-Dimensional Combustion Wave Model (From [7

  5. An evaluation of GTAW-P versus GTA welding of alloy 718

    NASA Technical Reports Server (NTRS)

    Gamwell, W. R.; Kurgan, C.; Malone, T. W.

    1991-01-01

    Mechanical properties were evaluated to determine statistically whether the pulsed current gas tungsten arc welding (GTAW-P) process produces welds in alloy 718 with room temperature structural performance equivalent to current Space Shuttle Main Engine (SSME) welds manufactured by the constant current GTAW-P process. Evaluations were conducted on two base metal lots, two filler metal lots, two heat input levels, and two welding processes. The material form was 0.125-inch (3.175-mm) alloy 718 sheet. Prior to welding, sheets were treated to either the ST or STA-1 condition. After welding, panels were left as welded or heat treated to the STA-1 condition, and weld beads were left intact or machined flush. Statistical analyses were performed on yield strength, ultimate tensile strength (UTS), and high cycle fatigue (HCF) properties for all the post welded material conditions. Analyses of variance were performed on the data to determine if there were any significant effects on UTS or HCF life due to variations in base metal, filler metal, heat input level, or welding process. Statistical analyses showed that the GTAW-P process does produce welds with room temperature structural performance equivalent to current SSME welds manufactured by the GTAW process, regardless of prior material condition or post welding condition.

  6. Stroop performance, dissociation, and trauma exposure in a community sample of children.

    PubMed

    DePrince, Anne P; Weinzierl, Kristin M; Combs, Melody D

    2008-01-01

    Extending previous research with adults, the current study examined Stroop task performance under selective and divided attention demands in a community sample of school-age children (N = 97). Stroop interference scores in both attention conditions were calculated. Higher levels of child-reported dissociation were associated with better interference control under divided attention conditions and worse control under selective attention conditions; lower levels of dissociation were associated with the opposite pattern. Both family violence exposure and Stroop interaction scores explained unique variance in dissociation scores. Although research with adults has generally assumed or implied that cognitive correlates of dissociation are a consequence of dissociation, the current findings with school-age children suggest that future research should evaluate executive function performance (in this case, interference control) as a possible risk factor for dissociation.

  7. Scope of physician procedures independently billed by mid-level providers in the office setting.

    PubMed

    Coldiron, Brett; Ratnarathorn, Mondhipa

    2014-11-01

    Mid-level providers (nurse practitioners and physician assistants) were originally envisioned to provide primary care services in underserved areas. This study details the current scope of independent procedural billing to Medicare of difficult, invasive, and surgical procedures by medical mid-level providers. To understand the scope of independent billing to Medicare for procedures performed by mid-level providers in an outpatient office setting for a calendar year. Analyses of the 2012 Medicare Physician/Supplier Procedure Summary Master File, which reflects fee-for-service claims that were paid by Medicare, for Current Procedural Terminology procedures independently billed by mid-level providers. Outpatient office setting among health care providers. The scope of independent billing to Medicare for procedures performed by mid-level providers. In 2012, nurse practitioners and physician assistants billed independently for more than 4 million procedures at our cutoff of 5000 paid claims per procedure. Most (54.8%) of these procedures were performed in the specialty area of dermatology. The findings of this study are relevant to safety and quality of care. Recently, the shortage of primary care clinicians has prompted discussion of widening the scope of practice for mid-level providers. It would be prudent to temper widening the scope of practice of mid-level providers by recognizing that mid-level providers are not solely limited to primary care, and may involve procedures for which they may not have formal training.

  8. Incorporating population-level variation in thermal performance into predictions of geographic range shifts.

    PubMed

    Angert, Amy L; Sheth, Seema N; Paul, John R

    2011-11-01

    Determining how species' geographic ranges are governed by current climates and how they will respond to rapid climatic change poses a major biological challenge. Geographic ranges are often spatially fragmented and composed of genetically differentiated populations that are locally adapted to different thermal regimes. Tradeoffs between different aspects of thermal performance, such as between tolerance to high temperature and tolerance to low temperature or between maximal performance and breadth of performance, suggest that the performance of a given population will be a subset of that of the species. Therefore, species-level projections of distribution might overestimate the species' ability to persist at any given location. However, current approaches to modeling distributions often do not consider variation among populations. Here, we estimated genetically-based differences in thermal performance curves for growth among 12 populations of the scarlet monkeyflower, Mimulus cardinalis, a perennial herb of western North America. We inferred the maximum relative growth rate (RGR(max)), temperature optimum (T(opt)), and temperature breadth (T(breadth)) for each population. We used these data to test for tradeoffs in thermal performance, generate mechanistic population-level projections of distribution under current and future climates, and examine how variation in aspects of thermal performance influences forecasts of range shifts. Populations differed significantly in RGR(max) and had variable, but overlapping, estimates of T(opt) and T(breadth). T(opt) declined with latitude and increased with temperature of origin, consistent with tradeoffs between performances at low temperatures versus those at high temperatures. Further, T(breadth) was negatively related to RGR(max), as expected for a specialist-generalist tradeoff. Parameters of the thermal performance curve influenced properties of projected distributions. For both current and future climates, T(opt) was negatively related to latitudinal position, while T(breadth) was positively related to projected range size. The magnitude and direction of range shifts also varied with T(opt) and T(breadth), but sometimes in unexpected ways. For example, the fraction of habitat remaining suitable increased with T(opt) but decreased with T(breadth). Northern limits of all populations were projected to shift north, but the magnitude of shift decreased with T(opt) and increased with T(breadth). Median latitude was projected to shift north for populations with high T(breadth) and low T(opt), but south for populations with low T(breadth) and high T(opt). Distributions inferred by integrating population-level projections did not differ from a species-level projection that ignored variation among populations. However, the species-level approach masked the potential array of divergent responses by populations that might lead to genotypic sorting within the species' range. Thermal performance tradeoffs among populations within the species' range had important, but sometimes counterintuitive, effects on projected responses to climatic change. © The Author 2011. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved.

  9. Nondissipative optimum charge regulator

    NASA Technical Reports Server (NTRS)

    Rosen, R.; Vitebsky, J. N.

    1970-01-01

    Optimum charge regulator provides constant level charge/discharge control of storage batteries. Basic power transfer and control is performed by solar panel coupled to battery through power switching circuit. Optimum controller senses battery current and modifies duty cycle of switching circuit to maximize current available to battery.

  10. Sputtering of sub-micrometer aluminum layers as compact, high-performance, light-weight current collector for supercapacitors

    NASA Astrophysics Data System (ADS)

    Busom, J.; Schreiber, A.; Tolosa, A.; Jäckel, N.; Grobelsek, I.; Peter, N. J.; Presser, V.

    2016-10-01

    Supercapacitors are devices for rapid and efficient electrochemical energy storage and commonly employ carbon coated aluminum foil as the current collector. However, the thickness of the metallic foil and the corresponding added mass lower the specific and volumetric performance on a device level. A promising approach to drastically reduce the mass and volume of the current collector is to directly sputter aluminum on the freestanding electrode instead of adding a metal foil. Our work explores the limitations and performance perspectives of direct sputter coating of aluminum onto carbon film electrodes. The tight and interdigitated interface between the metallic film and the carbon electrode enables high power handling, exceeding the performance and stability of a state-of-the-art carbon coated aluminum foil current collector. In particular, we find an enhancement of 300% in specific power and 186% in specific energy when comparing aluminum sputter coated electrodes with conventional electrodes with Al current collectors.

  11. Work Status, Work Satisfaction, and Blood Pressure Among Married Black and White Women

    ERIC Educational Resources Information Center

    Hauenstein, Louise S.; And Others

    1977-01-01

    This study examined blood pressure levels of married women in relation to such work-related variables as work load, satisfaction with work, reported strain, and evaluated performance. Differences in work load were unrelated to blood pressure levels. However, currently unemployed working women had lower levels. (Author)

  12. Empirically Examining the Performance of Approaches to Multi-Level Matching to Study the Effect of School-Level Interventions

    ERIC Educational Resources Information Center

    Hallberg, Kelly; Cook, Thomas D.; Figlio, David

    2013-01-01

    The goal of this paper is to provide guidance for applied education researchers in using multi-level data to study the effects of interventions implemented at the school level. Two primary approaches are currently employed in observational studies of the effect of school-level interventions. One approach employs intact school matching: matching…

  13. An evaluation of noise and its effects on shuttle crewmembers during STS-50/USML-1

    NASA Technical Reports Server (NTRS)

    Koros, Anton; Wheelwright, Charles; Adam, Susan

    1993-01-01

    High noise levels can lead to physiological, psychological, and performance effects in man, ranging from irritability, annoyance, and sleep interference to interference with verbal communication and fatigue, and to temporary or permanent threshold shift at more extreme levels. The current study evaluated the acoustic environment of the STS50/USML-1 mission. The major objectives were to gain subjective assessments of the STS-50 noise levels, document impacts of noise upon crewmember performance, collect inflight sound level measurements, compare noise levels across missions, evaluate the current Shuttle acoustic criterion, and to make recommendations regarding noise specifications for SSF and other long-duration manned space missions. Sound measurements indicated that background noise levels were 60, 64, and 61 A-weighted decibels, respectively, on the Orbiter middeck, flight deck, and Space lab. All levels were rated acceptable, with the Spacelab environment rated the most favorably. Sleep stations afforded attenuation from airborne noise sources, although all crewmembers reported being awakened by crew activity on the middeck. Models of distance for acceptable speech communications were generated, identifying situations of compromised verbal communications to be avoided.

  14. A DC Transformer

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C.; Ihlefeld, Curtis M.; Starr, Stanley O.

    2013-01-01

    A component level dc transformer is described in which no alternating currents or voltages are present. It operates by combining features of a homopolar motor and a homopolar generator, both de devices, such that the output voltage of a de power supply can be stepped up (or down) with a corresponding step down (or up) in current. The basic theory for this device is developed, performance predictions are made, and the results from a small prototype are presented. Based on demonstrated technology in the literature, this de transformer should be scalable to low megawatt levels, but it is more suited to high current than high voltage applications. Significant development would be required before it could achieve the kilovolt levels needed for de power transmission.

  15. Mild test anxiety influences neurocognitive performance among African Americans and European Americans: identifying interfering and facilitating sources.

    PubMed

    Thames, April D; Panos, Stella E; Arentoft, Alyssa; Byrd, Desiree A; Hinkin, Charles H; Arbid, Natalie

    2015-01-01

    The current study examined ethnic/racial differences in test-related anxiety and its relationship to neurocognitive performance in a community sample of African American (n = 40) and European American (n = 36) adults. The authors hypothesized the following: (a) Test-anxiety related to negative performance evaluation would be associated with lower neurocognitive performance, whereas anxiety unrelated to negative evaluation would be associated with higher neurocognitive performance. (b) African American participants would report higher levels of anxiety about negative performance evaluation than European Americans. (c) European Americans would report higher levels of anxiety unrelated to negative performance evaluation. The first two hypotheses were supported: Ethnic/racial differences in test-taking anxiety emerged such that African Americans reported significantly higher levels of negative performance evaluation, which was associated with lower cognitive performance. The third hypothesis was not supported: African Americans and European Americans reported similar levels of test-anxiety unrelated to negative evaluation. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  16. Emotional intelligence, performance, and retention in clinical staff nurses.

    PubMed

    Codier, Estelle; Kamikawa, Cindy; Kooker, Barbara M; Shoultz, Jan

    2009-01-01

    Emotional intelligence has been correlated with performance, retention, and organizational commitment in professions other than nursing. A 2006 pilot study provided the first evidence of a correlation between emotional intelligence and performance in clinical staff nurses. A follow-up study was completed, the purpose of which was to explore emotional intelligence, performance level, organizational commitment, and retention. A convenience sample of 350 nurses in a large medical center in urban Hawaii participated in this study. This article reports the findings pertaining to the subset of 193 clinical staff nurses who responded. The Mayer-Salovey-Caruso Emotional Intelligence Test instrument was used to measure emotional intelligence abilities. Performance was defined as ranking on a clinical ladder. Commitment was scored on a Likert scale. The following variables measured retention: total years in nursing, years in current job, total years anticipated in current job, and total anticipated career length. Emotional intelligence scores in clinical staff nurses correlated positively with both performance level and retention variables. Clinical staff nurses with higher emotional intelligence scores demonstrated higher performance, had longer careers, and greater job retention.

  17. Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording

    PubMed Central

    Kolb, Ilya; Kodandaramaiah, Suhasa B.; Chubykin, Alexander A.; Yang, Aimei; Bear, Mark F.; Boyden, Edward S.; Forest, Craig R.

    2014-01-01

    Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation. PMID:25429119

  18. Investigating the Performance of Omega Index According to Item Parameters and Ability Levels

    ERIC Educational Resources Information Center

    Sunbul, Onder; Yormaz, Seha

    2018-01-01

    Purpose: Several studies can be found in the literature that investigate the performance of ? under various conditions. However no study for the effects of item difficulty, item discrimination, and ability restrictions on the performance of ? could be found. The current study aims to investigate the performance of ? for the conditions given below.…

  19. Asphalt mixture cold temperature performance using the Bending Beam Rheometer (BBR).

    DOT National Transportation Integrated Search

    2013-03-01

    The use of recycled materials providing substitution of virgin binder in asphalt mixtures : continues to increase. The current level of funding for highway construction is : significantly less than 3 years ago and the level of competition between bid...

  20. Performance Characterization of the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) CCD Cameras

    NASA Astrophysics Data System (ADS)

    Joiner, R. K.; Kobayashi, K.; Winebarger, A. R.; Champey, P. R.

    2014-12-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument which is currently being developed by NASA's Marshall Space Flight Center (MSFC) and the National Astronomical Observatory of Japan (NAOJ). The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's Chromosphere to make measurements of the magnetic field in this region. In order to make accurate measurements of this effect, the performance characteristics of the three on-board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of no greater than 2 e-/DN, a noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non-linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.

  1. Performance of a 100 kW class applied field MPD thruster

    NASA Technical Reports Server (NTRS)

    Mantenieks, Maris A.; Sovey, James S.; Myers, Roger M.; Haag, Thomas W.; Raitano, Paul; Parkes, James E.

    1989-01-01

    Performance of a 100 kW, applied field magnetoplasmadynamic (MPD) thruster was evaluated and sensitivities of discharge characteristics to arc current, mass flow rate, and applied magnetic field were investigated. Thermal efficiencies as high as 60 percent, thrust efficiencies up to 21 percent, and specific impulses of up to 1150 s were attained with argon propellant. Thrust levels up to 2.5 N were directly measured with an inverted pendulum thrust stand at discharge input powers up to 57 kW. It was observed that thrust increased monotonically with the product of arc current and magnet current.

  2. Measuring Institutional Performance at the State Level.

    ERIC Educational Resources Information Center

    Bogue, E. G.

    The Performance Funding Project of the State of Tennessee is discussed. The Project was instituted to explore the question of whether it is desirable and possible to allocate some portion of state funds to community colleges and universities on a performance effectiveness criterion rather than the current credit hour and enrollment criteria. Major…

  3. Low-Arousal Speech Noise Improves Performance in N-Back Task: An ERP Study

    PubMed Central

    Zhang, Dandan; Jin, Yi; Luo, Yuejia

    2013-01-01

    The relationship between noise and human performance is a crucial topic in ergonomic research. However, the brain dynamics of the emotional arousal effects of background noises are still unclear. The current study employed meaningless speech noises in the n-back working memory task to explore the changes of event-related potentials (ERPs) elicited by the noises with low arousal level vs. high arousal level. We found that the memory performance in low arousal condition were improved compared with the silent and the high arousal conditions; participants responded more quickly and had larger P2 and P3 amplitudes in low arousal condition while the performance and ERP components showed no significant difference between high arousal and silent conditions. These findings suggested that the emotional arousal dimension of background noises had a significant influence on human working memory performance, and that this effect was independent of the acoustic characteristics of noises (e.g., intensity) and the meaning of speech materials. The current findings improve our understanding of background noise effects on human performance and lay the ground for the investigation of patients with attention deficits. PMID:24204607

  4. Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations

    NASA Technical Reports Server (NTRS)

    Montgomery, Demaris A.

    2001-01-01

    In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.

  5. Self-focused attention affects subsequent processing of positive (but not negative) performance appraisals.

    PubMed

    Holzman, Jacob B; Valentiner, David P

    2016-03-01

    Cognitive-behavioral models highlight the conjoint roles of self-focused attention (SFA), post-event processing (PEP), and performance appraisals in the maintenance of social anxiety. SFA, PEP, and biased performance appraisals are related to social anxiety; however, limited research has examined how SFA affects information-processing following social events. The current study examined whether SFA affects the relationships between performance appraisals and PEP following a social event.. 137 participants with high (n = 72) or low (n = 65) social anxiety were randomly assigned to conditions of high SFA or low SFA while engaging in a standardized social performance. Subsequent performance appraisals and PEP were measured. Immediate performance appraisals were not affected by SFA. High levels of SFA led to a stronger, inverse relationship between immediate positive performance appraisals and subsequent negative PEP. High levels of SFA also led to a stronger, inverse relationship between negative PEP and changes in positive performance appraisals.. Future research should examine whether the current findings, which involved a standardized social performance event, extend to interaction events as well as in a clinical sample. These findings suggest that SFA affects the processing of positive information following a social performance event. SFA is particularly important for understanding how negative PEP undermines positive performance appraisals.. Published by Elsevier Ltd.

  6. Investigation of mercury thruster isolators. [service life

    NASA Technical Reports Server (NTRS)

    Mantenieks, M. A.

    1973-01-01

    Mercury ion thruster isolator lifetime tests were performed using different isolator materials and geometries. Tests were performed with and without the flow of mercury through the isolators in an oil diffusion pumped vacuum facility and cryogenically pumped bell jar. The onset of leakage current in isolators tested occurred in time intervals ranging from a few hours to many hundreds of hours. In all cases, surface contamination was responsible for the onset of leakage current and subsequent isolator failure. Rate of increase of leakage current and the leakage current level increased approximately exponentially with isolator temperature. Careful attention to shielding techniques and the elimination of sources of metal oxides appear to have eliminated isolator failures as a thruster life limiting mechanism.

  7. Control of plasma process by use of harmonic frequency components of voltage and current

    DOEpatents

    Miller, Paul A.; Kamon, Mattan

    1994-01-01

    The present invention provides for a technique for taking advantage of the intrinsic electrical non-linearity of processing plasmas to add additional control variables that affect process performance. The technique provides for the adjustment of the electrical coupling circuitry, as well as the electrical excitation level, in response to measurements of the reactor voltage and current and to use that capability to modify the plasma characteristics to obtain the desired performance.

  8. Low power arcjet performance

    NASA Technical Reports Server (NTRS)

    Curran, Francis M.; Sarmiento, Charles J.

    1990-01-01

    An experimental investigation was performed to evaluate arc jet operation at low power. A standard, 1 kW, constricted arc jet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power engine. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope, The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

  9. Low power arcjet performance

    NASA Technical Reports Server (NTRS)

    Curran, Francis M.; Sarmiento, Charles J.

    1990-01-01

    An experimental investigation was performed to evaluate arcjet operation at low power. A standard, 1 kW, constricted arcjet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power regime. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope. The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

  10. Improved prediction models for PCC pavement performance-related specifications, volume I : final report.

    DOT National Transportation Integrated Search

    2000-12-01

    The current performance-related specifications (PRS) methodology has been under development by the Federal : Highway Administration (FHWA) for several years and has now reached a level at which it can be implemented by : State highway agencies. PRS f...

  11. ATLAS level-1 calorimeter trigger: Run-2 performance and Phase-1 upgrades

    NASA Astrophysics Data System (ADS)

    Carlson, Ben; Hong, Tae Min; Atlas Collaboration

    2017-01-01

    The Run-2 performance and Phase-1 upgrade are presented for the hardware-based level-1 calorimeter trigger (L1Calo) for the ATLAS Experiment. This trigger has a latency of about 2.2 microseconds to make a decision to help ATLAS select about 100 kHz of the most interesting collisions from the nominal LHC rate of 40 MHz. We summarize the upgrade after Run-1 (2009-2012) and discuss its performance in Run-2 (2015-current). We also outline the on-going Phase-1 upgrade for the next run (2021-2024) and its expected performance.

  12. RECONCILING ON-SITE STORMWATER BEST MANAGEMENT PRACTICE (BMP) EFFECTIVENESS AND PERFORMANCE WITH CURRENT HYDROLOGIC AND ECONOMIC PERCEPTIONS

    EPA Science Inventory

    There is currently a dearth of data characterizing best management practice impacts on runoff production at the parcel-level. This data is of critical importance insofar as judging the effectiveness and reliability of on-site stormwater BMPs, with significant implications for bot...

  13. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Chen, Y.; Shi, T.; Liu, Y.; Khatri, N. D.; Liu, J.; Yao, Y.; Xiong, X.; Lei, C.; Soloveichik, S.; Galstyan, E.; Majkic, G.

    2013-03-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm-2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m-3. The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  14. Characteristics and pathogenesis of facial nerve stimulation after cochlear implant surgeries: A single-center retrospective analysis from 1,151 patients.

    PubMed

    Kim, Y R; Yoo, M H; Lee, J Y; Yang, C J; Park, J W; Kang, B C; Kang, W S; Ahn, J H; Chung, J W; Park, H J

    2018-05-29

    Incidence of facial nerve stimulation (FNS) was 2.8% (32 out of 1151) and higher in ears with cochlear anomaly (6.4%, 25 out of 391) than without cochlear anomaly (0.9%, 7 out of 760). FNS occurred at various current levels and locations of electrodes by different mechanisms related to incomplete insertion of electrodes, cochleo-facial dehiscence, and types of cochlear anomalies. FNS at apical electrodes related to cochleo-facial dehiscence with low current levels, and FNS at basal electrodes with high current levels and partial insertion of electrodes. FNS at most electrodes with high current levels was the most common type in patients with a common cavity or narrowing of the bony cochlear nerve canal. Understanding the mechanisms of FNS might provide insight for preventing FNS when performing CI surgeries. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. An investigation of sensory information, levels of automation, and piloting experience on unmanned aircraft pilot performance.

    DOT National Transportation Integrated Search

    2012-03-01

    "The current experiment was intended to examine the effect of sensory information on pilot reactions to system : failures within a UAS control station simulation. This research also investigated the level of automation used in : controlling the aircr...

  16. Calibration and Initialization of the NPS Modified Infrared Search and Target Designation (IRSTD) System.

    DTIC Science & Technology

    1987-12-01

    level of performance comparable to the original ADM configuration. ’p, OTIC CPY Acesion For NTiS CRA&I UTNY’ TAB [ arinc ,:,cced 0 C yfi.’ hb .vC.Je i...levels below standard. This modified system was found to be operating at a level of performance comparable to the original ADM configuration. 4’ TABLE OF...requirements for systems that function under conditions of emissions control (EMCON). The AN/SAR-8, currently in the Engineering Development Phase , is an

  17. Mist characterization in drilling 1018 steel

    NASA Astrophysics Data System (ADS)

    Cole, Ian

    Minimum quantity lubrication replaces the traditional method of flood cooling with small amounts of high-efficient lubrication. Limited studies have been performed to determine the characteristics of mist produced during MQL. This study investigated the mist concentration levels produced while drilling 1018 steel using a vegetable based lubricant. ANOVA was performed to determine whether speed and feed rates or their interactions have a significant effect on mist concentration levels and particle diameter. It was observed that the concentration levels obtained under all four speed and feed rate combinations studied exceeded the current OSHA and NIOSH standards.

  18. Missing Data Treatments at the Second Level of Hierarchical Linear Models

    ERIC Educational Resources Information Center

    St. Clair, Suzanne W.

    2011-01-01

    The current study evaluated the performance of traditional versus modern MDTs in the estimation of fixed-effects and variance components for data missing at the second level of an hierarchical linear model (HLM) model across 24 different study conditions. Variables manipulated in the analysis included, (a) number of Level-2 variables with missing…

  19. Direct current performance and current collapse in AlGaN/GaN insulated gate high-electron mobility transistors on Si (1 1 1) substrate with very thin SiO2 gate dielectric

    NASA Astrophysics Data System (ADS)

    Lachab, M.; Sultana, M.; Fatima, H.; Adivarahan, V.; Fareed, Q.; Khan, M. A.

    2012-12-01

    This work reports on the dc performance of AlGaN/GaN metal-oxide-semiconductor high electron mobility transistors (MOSHEMTs) grown on Si (1 1 1) substrate and the study of current dispersion in these devices using various widely adopted methods. The MOSHEMTs were fabricated using a very thin (4.2 nm) SiO2 film as the gate insulator and were subsequently passivated with about 30 nm thick Si3N4 layer. For devices with 2.5 µm long gates and a 4 µm drain-to-source spacing, the maximum saturation drain current density was 822 mA mm-1 at + 4 V gate bias and the peak external transconductance was ˜100 mS mm-1. Furthermore, the oxide layer successfully suppressed the drain and gate leakage currents with the subthreshold current and the gate diode current levels exceeding by more than three orders of magnitude the levels found in their Schottky gate counterparts. Capacitance-voltage and dynamic current-voltage measurements were carried out to assess the oxide quality as well as the devices’ surface properties after passivation. The efficacy of each of these characterization techniques to probe the presence of interface traps and oxide charge in the nitride-based transistors is also discussed.

  20. Scaling of Counter-Current Imbibition Process in Low-Permeability Porous Media, TR-121

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kvoscek, A.R.; Zhou, D.; Jia, L.

    2001-01-17

    This project presents the recent work on imaging imbibition in low permeability porous media (diatomite) with X-ray completed tomography. The viscosity ratio between nonwetting and wetting fluids is varied over several orders of magnitude yielding different levels of imbibition performance. Also performed is mathematical analysis of counter-current imbibition processes and development of a modified scaling group incorporating the mobility ratio. This modified group is physically based and appears to improve scaling accuracy of countercurrent imbibition significantly.

  1. Advanced Small Free-Piston Stirling Convertors for Space Power Applications

    NASA Astrophysics Data System (ADS)

    Wood, J. Gary; Lane, Neill

    2004-02-01

    This paper reports on the current status of an advanced 35 We free-piston Stirling convertor currently being developed under NASA SBIR Phase II funding. Also described is a further advanced and higher performance ~80 watt free-piston convertor being developed by Sunpower and Boeing/Rocketdyne for NASA under NRA funding. Exceptional overall convertor (engine plus linear alternator) thermodynamic performance (greater than 50% of Carnot) with specific powers around 100 We /kg appear reasonable at these low power levels.

  2. Relationships of Mathematics Anxiety, Mathematics Self-Efficacy and Mathematics Performance of Adult Basic Education Students

    ERIC Educational Resources Information Center

    Watts, Beverly Kinsey

    2011-01-01

    Competent mathematical skills are needed in the workplace as well as in the college setting. Adults in Adult Basic Education classes and programs generally perform below high school level competency, but very few studies have been performed investigating the predictors of mathematical success for adults. The current study contributes to the…

  3. Test Report - Fault Current Through Graphite Filament Reinforced Plastic

    NASA Technical Reports Server (NTRS)

    Evans, R. W.

    1997-01-01

    Tests were performed to determine the damage to samples of composite material when a current carrying wire is shorted to the surface of the composite material, and to determine whether enough current can flow through the material to blow a fuse before damage can occur. Fault current tests were performed on samples of graphite epoxy materials. Samples consisted of six layers of IM7 graphite fiber mat in Hercules 8552 epoxy resin. A variable power supply provided up to 35 amps of current. The high voltage side of the power supply was attached to a wire at the end of a hinged arm, and the low side was attached to the edge of the sample. To test joints, the return was connected to the edge of one sample, and the high side was shorted to the top of the other sample. Tests show that when current exceeds approximately 5 amps, the graphite glows, and the epoxy melts out at the shorted contact. At higher current levels the epoxy burns. At voltages above 15 volts the epoxy outer coat is easily broken, and fire, flame, and a rise in current occur suddenly. When joints are introduced, resistance is increased, and the maximum current resulting from a short circuit to the graphite epoxy is reduced. This condition can easily result in fault current lower than the circuit breaker limit and higher than the 5 amp ignition level. The shorting contact and the joint become hot spots with melting epoxy, smoke, and fire.

  4. Body composition for health and performance: a survey of body composition assessment practice carried out by the Ad Hoc Research Working Group on Body Composition, Health and Performance under the auspices of the IOC Medical Commission.

    PubMed

    Meyer, Nanna L; Sundgot-Borgen, Jorunn; Lohman, Timothy G; Ackland, Timothy R; Stewart, Arthur D; Maughan, Ronald J; Smith, Suzanne; Müller, Wolfram

    2013-11-01

    Successful performers in weight-sensitive sports are characterised by low body mass (BM) and fat content. This often requires chronic energy restriction and acute weight loss practices. To evaluate current use of body composition (BC) assessment methods and identify problems and solutions with current BC approaches. A 40-item survey was developed, including demographic and content questions related to BC assessment. The survey was electronically distributed among international sporting organisations. Frequencies and χ(2) analyses were computed. 216 responses were received, from 33 countries, representing various institutions, sports and competitive levels. Of the sample, 86% of respondents currently assess BC, most frequently using skinfolds (International Society for the Advancement of Kinanthropometry (ISAK): 50%; non-ISAK, conventional: 40%; both: 28%), dual energy X-ray absorptiometry (38%), bioelectrical impedance (29%), air displacement plethysmography (17%) and hydrostatic weighing (10%). Of those using skinfolds, more at the international level used ISAK, whereas conventional approaches were more reported at regional/national level (p=0.006). The sport dietitian/nutritionist (57%) and physiologist/sports scientist (54%) were most frequently the professionals assessing BC, followed by MDs and athletic trainers, with some reporting coaches (5%). 36% of 116 respondents assessed hydration status and more (64%) did so at international than regional/national level (36%, p=0.028). Of 125 participants answering the question of whether they thought that BC assessment raised problems, 69% said 'yes', with most providing ideas for solutions. Results show high use of BC assessment but also a lack of standardisation and widespread perception of problems related to BM and BC in sport. Future work should emphasise standardisation with appropriate training opportunities and more research on BC and performance.

  5. Improved prediction models for PCC pavement performance-related specifications, volume II : PaveSpec 3.0 user's guide.

    DOT National Transportation Integrated Search

    2001-12-01

    The current performance-related specifications (PRS) methodology has been under development by the Federal : Highway~Administration (FI-IWA) for several years and has now reached a level at which it can be implemented by : State highway agencies. PRS...

  6. Modeling Human Performance: Effects of Personal Traits and Transitory States

    DTIC Science & Technology

    2002-06-01

    Self Confidence High Self Confidence Extroversion Introversion External Locus of Control Internal Locus of Control Positive Personality Case In the...levels, emotions may not have any effect on performance whatsoever. The current model does not recognize that there may be emotion thresholds that must be

  7. Development and Application of an Integrated Approach toward NASA Airspace Systems Research

    NASA Technical Reports Server (NTRS)

    Barhydt, Richard; Fong, Robert K.; Abramson, Paul D.; Koenke, Ed

    2008-01-01

    The National Aeronautics and Space Administration's (NASA) Airspace Systems Program is contributing air traffic management research in support of the 2025 Next Generation Air Transportation System (NextGen). Contributions support research and development needs provided by the interagency Joint Planning and Development Office (JPDO). These needs generally call for integrated technical solutions that improve system-level performance and work effectively across multiple domains and planning time horizons. In response, the Airspace Systems Program is pursuing an integrated research approach and has adapted systems engineering best practices for application in a research environment. Systems engineering methods aim to enable researchers to methodically compare different technical approaches, consider system-level performance, and develop compatible solutions. Systems engineering activities are performed iteratively as the research matures. Products of this approach include a demand and needs analysis, system-level descriptions focusing on NASA research contributions, system assessment and design studies, and common systemlevel metrics, scenarios, and assumptions. Results from the first systems engineering iteration include a preliminary demand and needs analysis; a functional modeling tool; and initial system-level metrics, scenario characteristics, and assumptions. Demand and needs analysis results suggest that several advanced concepts can mitigate demand/capacity imbalances for NextGen, but fall short of enabling three-times current-day capacity at the nation s busiest airports and airspace. Current activities are focusing on standardizing metrics, scenarios, and assumptions, conducting system-level performance assessments of integrated research solutions, and exploring key system design interfaces.

  8. Current Knowledge and Projection on Assessing the Effectiveness of Training.

    ERIC Educational Resources Information Center

    Orlansky, Jesse

    This discussion of methods used to assess the effectiveness of training for U.S. Army personnel identifies various types of training, describes methods currently used, and suggests ways of improving the assessment process. The methodology and results of assessments of effectiveness, including the costs associated with the level of performance, are…

  9. 78 FR 4960 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing of Proposed Rule Change Relating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-23

    ... level of current income, while preserving capital. \\14\\ A ``top-down'' portfolio management style... overall performance. This management style begins with a look at the overall economic picture and current... registered with the Commission as an open-end management investment company.\\6\\ \\4\\ The Commission has...

  10. The Devalued Student: Misalignment of Current Mathematics Knowledge and Level of Instruction

    ERIC Educational Resources Information Center

    LeMire, Steven D.; Melby, Marcella L.; Haskins, Anne M.; Williams, Tony

    2012-01-01

    Within this study, we investigated the association between 10th-grade students' mathematics performance and their feelings of instructional misalignment between their current mathematics knowledge and educator support. Data from the 2002 Education Longitudinal Study, which included a national sample of 750 public and private high schools in the…

  11. Aggregation of Electric Current Consumption Features to Extract Maintenance KPIs

    NASA Astrophysics Data System (ADS)

    Simon, Victor; Johansson, Carl-Anders; Galar, Diego

    2017-09-01

    All electric powered machines offer the possibility of extracting information and calculating Key Performance Indicators (KPIs) from the electric current signal. Depending on the time window, sampling frequency and type of analysis, different indicators from the micro to macro level can be calculated for such aspects as maintenance, production, energy consumption etc. On the micro-level, the indicators are generally used for condition monitoring and diagnostics and are normally based on a short time window and a high sampling frequency. The macro indicators are normally based on a longer time window with a slower sampling frequency and are used as indicators for overall performance, cost or consumption. The indicators can be calculated directly from the current signal but can also be based on a combination of information from the current signal and operational data like rpm, position etc. One or several of those indicators can be used for prediction and prognostics of a machine's future behavior. This paper uses this technique to calculate indicators for maintenance and energy optimization in electric powered machines and fleets of machines, especially machine tools.

  12. Performance Characterization of the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) CCD Cameras

    NASA Technical Reports Server (NTRS)

    Joiner, Reyann; Kobayashi, Ken; Winebarger, Amy; Champey, Patrick

    2014-01-01

    The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument currently being developed by NASA's Marshall Space Flight Center (MSFC), the National Astronomical Observatory of Japan (NAOJ), and other partners. The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's chromosphere. The polarized spectrum imaged by the CCD cameras will capture information about the local magnetic field, allowing for measurements of magnetic strength and structure. In order to make accurate measurements of this effect, the performance characteristics of the three on- board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, read noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of 2.0+/- 0.5 e--/DN, a read noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non- linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.

  13. Plasma pro-surfactant protein B and lung function decline in smokers.

    PubMed

    Leung, Janice M; Mayo, John; Tan, Wan; Tammemagi, C Martin; Liu, Geoffrey; Peacock, Stuart; Shepherd, Frances A; Goffin, John; Goss, Glenwood; Nicholas, Garth; Tremblay, Alain; Johnston, Michael; Martel, Simon; Laberge, Francis; Bhatia, Rick; Roberts, Heidi; Burrowes, Paul; Manos, Daria; Stewart, Lori; Seely, Jean M; Gingras, Michel; Pasian, Sergio; Tsao, Ming-Sound; Lam, Stephen; Sin, Don D

    2015-04-01

    Plasma pro-surfactant protein B (pro-SFTPB) levels have recently been shown to predict the development of lung cancer in current and ex-smokers, but the ability of pro-SFTPB to predict measures of chronic obstructive pulmonary disease (COPD) severity is unknown. We evaluated the performance characteristics of pro-SFTPB as a biomarker of lung function decline in a population of current and ex-smokers. Plasma pro-SFTPB levels were measured in 2503 current and ex-smokers enrolled in the Pan-Canadian Early Detection of Lung Cancer Study. Linear regression was performed to determine the relationship of pro-SFTPB levels to changes in forced expiratory volume in 1 s (FEV1) over a 2-year period as well as to baseline FEV1 and the burden of emphysema observed in computed tomography (CT) scans. Plasma pro-SFTPB levels were inversely related to both FEV1 % predicted (p=0.024) and FEV1/forced vital capacity (FVC) (p<0.001), and were positively related to the burden of emphysema on CT scans (p<0.001). Higher plasma pro-SFTPB levels were also associated with a more rapid decline in FEV1 at 1 year (p=0.024) and over 2 years of follow-up (p=0.004). Higher plasma pro-SFTPB levels are associated with increased severity of airflow limitation and accelerated decline in lung function. Pro-SFTPB is a promising biomarker for COPD severity and progression. Copyright ©ERS 2015.

  14. Current Evidence Regarding the Diagnostic Methods for Pediatric Lumbar Spondylolisthesis: A Report From the Scoliosis Research Society Evidence Based Medicine Committee.

    PubMed

    Kim, Han Jo; Crawford, Charles H; Ledonio, Charles; Bess, Shay; Larson, A Noelle; Gates, Marilyn; Oetgen, Matthew; Sanders, James O; Burton, Douglas

    Structured literature review. The Scoliosis Research Society (SRS) requested an assessment of the current state of peer-reviewed evidence regarding pediatric lumbar spondylolisthesis with the goal of identifying what is known and what gaps remain in further understanding the diagnostic methods for pediatric spondylolisthesis. Spondylolisthesis in the lumbar spine is common among children and adolescents and no formal synthesis of the published literature regarding diagnostic methods has been previously performed. A comprehensive literature search was performed. Abstracts were reviewed and data from included studies were analyzed by the committee. From 6600 initial citations with abstract, 663 articles underwent full-text review. The best available evidence for the clinical questions regarding diagnostic methods was provided by 26 included studies. Six of the studies were graded as Level III (retrospective comparative), and represent the current best available evidence whereas 20 of the studies were graded as Level IV (retrospective case series) evidence. No Level V (expert opinion) studies were included in the final list. None of the studies were graded as Level I or Level II. Plain radiography is the workhorse imaging modality for diagnosing spondylolisthesis. No association between radiologic grade of spondylolisthesis and clinical presentation were noted; however, grade III and IV slips more often required surgery, and increasing slip angles were associated with worse baseline outcome scores. There is Level III evidence that the Meyerding grade appears to be more accurate for measuring slip percentage whereas the Lonstein Slip angle and Dubousset Lumbosacral Kyphosis angles are the best for measuring lumbosacral kyphosis in spondylolisthesis. In addition, higher sacral table index, pelvic incidence, sacral slope, and lower sacral table angle were associated with spondylolisthesis. True incidence could not be determined by the current literature available. However, studies in adolescent athletes demonstrated an incidence of 6% to 7% across studies. The current "best available" evidence to guide the diagnosis and characterization of pediatric spondylolisthesis is presented. Future studies are needed to provide more high-quality evidence to answer these clinically relevant questions. Level III, review of Level III studies. Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  15. Life Science Literacy of an Undergraduate Population

    ERIC Educational Resources Information Center

    Medina, Stephanie R.; Ortlieb, Evan; Metoyer, Sandra

    2014-01-01

    Science content knowledge is a concern for educators in the United States because performance has stagnated for the past decade. Investigators designed this study to determine the current levels of scientific literacy among undergraduate students in a freshman-level biology course (a core requirement for majors and nonmajors), identify factors…

  16. Assessment of Job Satisfaction among Faculty Members and Its Relationship with Some Variables in Najran University

    ERIC Educational Resources Information Center

    Al-Smadi, Marwan Saleh; Qblan, Yahya Mohammed

    2015-01-01

    It is vital that colleges and universities monitor the satisfaction levels of their employees to secure high levels of their performance. The current study aimed to identify the impact of some variables (gender, Teaching experience and college type) on assessing the level of job satisfaction among faculty of Najran University. A survey was…

  17. Updated Mars Mission Architectures Featuring Nuclear Thermal Propulsion

    NASA Technical Reports Server (NTRS)

    Rodriguez, Mitchell A.; Percy, Thomas K.

    2017-01-01

    Nuclear thermal propulsion (NTP) can potentially enable routine human exploration of Mars and the solar system. By using nuclear fission instead of a chemical combustion process, and using hydrogen as the propellant, NTP systems promise rocket efficiencies roughly twice that of the best chemical rocket engines currently available. The most recent major Mars architecture study featuring NTP was the Design Reference Architecture 5.0 (DRA 5.0), performed in 2009. Currently, the predominant transportation options being considered are solar electric propulsion (SEP) and chemical propulsion; however, given NTP's capabilities, an updated architectural analysis is needed. This paper provides a top-level overview of several different architectures featuring updated NTP performance data. New architectures presented include a proposed update to the DRA 5.0 as well as an investigation of architectures based on the current Evolvable Mars Campaign, which is the focus of NASA's current analyses for the Journey to Mars. Architectures investigated leverage the latest information relating to NTP performance and design considerations and address new support elements not available at the time of DRA 5.0, most notably the Orion crew module and the Space Launch System (SLS). The paper provides a top level quantitative comparison of key performance metrics as well as a qualitative discussion of improvements and key challenges still to be addressed. Preliminary results indicate that the updated NTP architectures can significantly reduce the campaign mass and subsequently the costs for assembly and number of launches.

  18. Patterns of Hospital Performance on the Hospital-Wide 30-Day Readmission Metric: Is the Playing Field Level?

    PubMed

    Hoyer, Erik H; Padula, William V; Brotman, Daniel J; Reid, Natalie; Leung, Curtis; Lepley, Diane; Deutschendorf, Amy

    2018-01-01

    Hospital performance on the 30-day hospital-wide readmission (HWR) metric as calculated by the Centers for Medicare and Medicaid Services (CMS) is currently reported as a quality measure. Focusing on patient-level factors may provide an incomplete picture of readmission risk at the hospital level to explain variations in hospital readmission rates. To evaluate and quantify hospital-level characteristics that track with hospital performance on the current HWR metric. Retrospective cohort study. A total of 4785 US hospitals. We linked publically available data on individual hospitals published by CMS on patient-level adjusted 30-day HWR rates from July 1, 2011, through June 30, 2014, to the 2014 American Hospital Association annual survey. Primary outcome was performance in the worst CMS-calculated HWR quartile. Primary hospital-level exposure variables were defined as: size (total number of beds), safety net status (top quartile of disproportionate share), academic status [member of the Association of American Medical Colleges (AAMC)], National Cancer Institute Comprehensive Cancer Center (NCI-CCC) status, and hospital services offered (e.g., transplant, hospice, emergency department). Multilevel regression was used to evaluate the association between 30-day HWR and the hospital-level factors. Hospital-level characteristics significantly associated with performing in the worst CMS-calculated HWR quartile included: safety net status [adjusted odds ratio (aOR) 1.99, 95% confidence interval (95% CI) 1.61-2.45, p < 0.001], large size (> 400 beds, aOR 1.42, 95% CI 1.07-1.90, p = 0.016), AAMC alone status (aOR 1.95, 95% CI 1.35-2.83, p < 0.001), and AAMC plus NCI-CCC status (aOR 5.16, 95% CI 2.58-10.31, p < 0.001). Hospitals with more critical care beds (aOR 1.26, 95% CI 1.02-1.56, p = 0.033), those with transplant services (aOR 2.80, 95% CI 1.48-5.31,p = 0.001), and those with emergency room services (aOR 3.37, 95% CI 1.12-10.15, p = 0.031) demonstrated significantly worse HWR performance. Hospice service (aOR 0.64, 95% CI 0.50-0.82, p < 0.001) and having a higher proportion of total discharges being surgical cases (aOR 0.62, 95% CI 0.50-0.76, p < 0.001) were associated with better performance. The study approach was not intended to be an alternate readmission metric to compete with the existing CMS metric, which would require a re-examination of patient-level data combined with hospital-level data. A number of hospital-level characteristics (such as academic tertiary care center status) were significantly associated with worse performance on the CMS-calculated HWR metric, which may have important health policy implications. Until the reasons for readmission variability can be addressed, reporting the current HWR metric as an indicator of hospital quality should be reevaluated.

  19. Handwriting Automaticity: The Search for Performance Thresholds

    ERIC Educational Resources Information Center

    Medwell, Jane; Wray, David

    2014-01-01

    Evidence is accumulating that handwriting has an important role in written composition. In particular, handwriting automaticity appears to relate to success in composition. This relationship has been little explored in British contexts and we currently have little idea of what threshold performance levels might be. In this paper, we report on two…

  20. Reforming Teacher Pay

    ERIC Educational Resources Information Center

    Burns, Susan Freeman; Gardner, Catherine D.

    2010-01-01

    A recent Google search for information regarding performance pay in education produced 6.1 million results. This number should come as no surprise given the current level of interest in incentives as a popular reform option in public education. Supporters believe pay-for-performance programs encourage less effective teachers to improve and will…

  1. Making Learning Happen: Strategies for an Interactive Classroom.

    ERIC Educational Resources Information Center

    Golub, Jeffrey N.

    This is a book about "conscious learning," the kind of learning that enables students to assess the current level and quality of their language performance and then work to improve that performance deliberately, enthusiastically, and with commitment. The book takes complex, sophisticated understandings and reworks them into ready-to-use…

  2. Step by Step Learning Using the I Diagram in the Systematic Qualitative Analyses of Cations within a Guided Inquiry Learning Approach

    ERIC Educational Resources Information Center

    Akkuzu, Nalan; Uyulgan, Melis Arzu

    2017-01-01

    The current study examines the performance and achievement of students in the Systematic Qualitative Analyses of Cations (SQACs). We sought answers to questions such as, "What are the students' levels of performance?" and "What is the relation between the average scores for performance and achievement?." This was done by using…

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selvamanickam, V; Chen, Y; Shi, T

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12more » mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.« less

  4. Evaluation of nurse staffing levels and outcomes under the government--recommended staffing levels in Korea.

    PubMed

    Yu, Soyoung; Kim, Tae Gon

    2015-05-01

    This study aimed to evaluate registered nurse staffing levels and outcomes enforced by the current Korean nursing regulations. Registered nurse staffing levels are closely related to patient and nurse outcomes. Thus, the government's policy regarding nursing staffing has a practical impact, and better policies could lead to more appropriate nurse staffing. The actual evaluation of the government-recommended staffing levels in Korea is paramount for the establishment of a realistic and effective system that promotes quality care and patient safety. The participating hospital operated under the government-recommended staffing levels (Grade 2 of the Graded Fee of Nursing Management Inpatient System). For unit-level evaluations, one surgical unit was chosen and its staffing level was changed by assigning one additional registered nurse for 6 months. Length of hospitalisation, incidents of death, overtime hours and nursing job performance were measured prior to and after the addition of the extra staff. After 6 months, the length of patient hospitalisation and registered nurse overtime hours reduced and nurse job performance scores in the unit analysed improved. The results demonstrated that increasing the number of registered nurses beyond the current government-recommended staffing level improves patient and nurse outcomes. This indicates the importance and value of empirically assessing the need for changes in the recommended nurse staffing levels to develop appropriate, realistic and effective policies. © 2013 John Wiley & Sons Ltd.

  5. Flight Crew Factors for CTAS/FMS Integration in the Terminal Area

    NASA Technical Reports Server (NTRS)

    Crane, Barry W.; Prevot, Thomas; Palmer, Everett A.; Shafto, M. (Technical Monitor)

    2000-01-01

    Center TRACON Automation System (CTAS)/Flight Management System (FMS) integration on the flightdeck implies flight crews flying coupled in highly automated FMS modes [i.e. Vertical Navigation (VNAV) and Lateral Navigation (LNAV)] from top of descent to the final approach phase of flight. Pilots may also have to make FMS route edits and respond to datalink clearances in the Terminal Radar Approach Control (TRACON) airspace. This full mission simulator study addresses how the introduction of these FMS descent procedures affect crew activities, workload, and performance. It also assesses crew acceptance of these procedures. Results indicate that the number of crew activities and workload ratings are significantly reduced below current day levels when FMS procedures can be flown uninterrupted, but that activity numbers increase significantly above current day levels and workload ratings return to current day levels when FMS procedures are interrupted by common ATC interventions and CTAS routing advisories. Crew performance showed some problems with speed control during FMS procedures. Crew acceptance of the FMS procedures and route modification requirements was generally high; a minority of crews expressed concerns about use of VNAV in the TRACON airspace. Suggestions for future study are discussed.

  6. Effect of incorporation of nitrogen atoms in Al2O3 gate dielectric of wide-bandgap-semiconductor MOSFET on gate leakage current and negative fixed charge

    NASA Astrophysics Data System (ADS)

    Kojima, Eiji; Chokawa, Kenta; Shirakawa, Hiroki; Araidai, Masaaki; Hosoi, Takuji; Watanabe, Heiji; Shiraishi, Kenji

    2018-06-01

    We performed first-principle calculations to investigate the effect of incorporation of N atoms into Al2O3 gate dielectrics. Our calculations show that the defect levels generated by VO in Al2O3 are the origin of the stress-induced gate leakage current and that VOVAl complexes in Al2O3 cause negative fixed charge. We revealed that the incorporation of N atoms into Al2O3 eliminates the VO defect levels, reducing the stress-induced gate leakage current. Moreover, this suppresses the formation of negatively charged VOVAl complexes. Therefore, AlON can reduce both stress-induced gate leakage current and negative fixed charge in wide-bandgap-semiconductor MOSFETs.

  7. Open airscrew VTOL concepts

    NASA Technical Reports Server (NTRS)

    Stepniewski, W. Z.; Tarczynski, T.

    1992-01-01

    The following concepts, based on using open airscrew(s) for VTOL maneuvers, are re-examined in light of current technology: (1) tip-driven helicopters, (2) compound helicopters; and (3) high-speed VTOL aircraft, represented by tiltrotors, tiltwings, retractoplanes and stoppable rotors. Criteria, permitting one to compare performance of aircraft using diverse lifting and propelling methods are established. Determination of currently possible performance, indication of near-future potentials, and comparison of those items with the baseline levels (as represented by contemporary shaft-driven helicopters, first generation tiltrotors, and commercial turboprop fixed-wind aircraft) constitutes bulk of this report.

  8. Fractional Factorial Design Study on the Performance of GAC-Enhanced Electrocoagulation Process Involved in Color Removal from Dye Solutions

    PubMed Central

    Secula, Marius Sebastian; Cretescu, Igor; Cagnon, Benoit; Manea, Liliana Rozemarie; Stan, Corneliu Sergiu; Breaban, Iuliana Gabriela

    2013-01-01

    The aim of this study was to determine the effects of main factors and interactions on the color removal performance from dye solutions using the electrocoagulation process enhanced by adsorption on Granular Activated Carbon (GAC). In this study, a mathematical approach was conducted using a two-level fractional factorial design (FFD) for a given dye solution. Three textile dyes: Acid Blue 74, Basic Red 1, and Reactive Black 5 were used. Experimental factors used and their respective levels were: current density (2.73 or 27.32 A/m2), initial pH of aqueous dye solution (3 or 9), electrocoagulation time (20 or 180 min), GAC dose (0.1 or 0.5 g/L), support electrolyte (2 or 50 mM), initial dye concentration (0.05 or 0.25 g/L) and current type (Direct Current—DC or Alternative Pulsed Current—APC). GAC-enhanced electrocoagulation performance was analyzed statistically in terms of removal efficiency, electrical energy, and electrode material consumptions, using modeling polynomial equations. The statistical significance of GAC dose level on the performance of GAC enhanced electrocoagulation and the experimental conditions that favor the process operation of electrocoagulation in APC regime were determined. The local optimal experimental conditions were established using a multi-objective desirability function method. PMID:28811405

  9. Amateur boxing: physical and physiological attributes.

    PubMed

    Chaabène, Helmi; Tabben, Montassar; Mkaouer, Bessem; Franchini, Emerson; Negra, Yassine; Hammami, Mehrez; Amara, Samiha; Chaabène, Raja Bouguezzi; Hachana, Younés

    2015-03-01

    Boxing is one of the oldest combat sports. The aim of the current review is to critically analyze the amateur boxer's physical and physiological characteristics and to provide practical recommendations for training as well as new areas of scientific research. High-level male and female boxers show a propensity for low body fat levels. Although studies on boxer somatotypes are limited, the available information shows that elite-level male boxers are characterized by a higher proportion of mesomorphy with a well-developed muscle mass and a low body fat level. To help support the overall metabolic demands of a boxing match and to accelerate the recovery process between rounds, athletes of both sexes require a high level of cardiorespiratory fitness. International boxers show a high peak and mean anaerobic power output. Muscle strength in both the upper and lower limbs is paramount for a fighter's victory and is one of the keys to success in boxing. As boxing punches are brief actions and very dynamic, high-level boxing performance requires well-developed muscle power in both the upper and lower limbs. Albeit limited, the available studies reveal that isometric strength is linked to high-level boxing performance. Future investigations into the physical and physiological attributes of boxers are required to enrich the current data set and to help create a suitable training program.

  10. Basal salivary oxytocin level predicts extra- but not intra-personal dimensions of emotional intelligence.

    PubMed

    Koven, Nancy S; Max, Laura K

    2014-06-01

    A wealth of literature suggests that oxytocin is an important mediator of social cognition, but much of the research to date has relied on pharmaceutical administration methods that can raise oxytocin to artificially high levels. The present study builds upon previous work by examining whether basal oxytocin level predicts intra- and extra-personal (i.e., self- and other-focused) elements of emotional intelligence (EI), independent of shared variance with current mood. The sample included 71 healthy young adults (46 women). Assessment measures included the Mayer-Salovey-Caruso Emotional Intelligence Test Version 2.0 (MSCEIT), the Trait Meta-Mood Scale, and the Profile of Mood States. Peripheral oxytocin levels were examined with enzyme-linked immunosorbent assay from saliva after solid phase extraction. Oxytocin level was unrelated to TMMS scores but was positively associated with performance in the Experiential EI domain of the MSCEIT. However, total mood disturbance was positively related to MSCEIT scores. Hierarchical regression analysis indicated that oxytocin level added unique variance to the prediction of MSCEIT performance beyond that of current mood. These results confirm an association between endogenous levels of oxytocin in healthy adults and a subset of EI abilities, including extra-personal emotion recognition and the channeling of emotions to enhance social proficiency. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. A 32-Channel Combined RF and B0 Shim Array for 3T Brain Imaging

    PubMed Central

    Stockmann, Jason P.; Witzel, Thomas; Keil, Boris; Polimeni, Jonathan R.; Mareyam, Azma; LaPierre, Cristen; Setsompop, Kawin; Wald, Lawrence L.

    2016-01-01

    Purpose We add user-controllable direct currents (DC) to the individual elements of a 32-channel radio-frequency (RF) receive array to provide B0 shimming ability while preserving the array’s reception sensitivity and parallel imaging performance. Methods Shim performance using constrained DC current (±2.5A) is simulated for brain arrays ranging from 8 to 128 elements. A 32-channel 3-tesla brain array is realized using inductive chokes to bridge the tuning capacitors on each RF loop. The RF and B0 shimming performance is assessed in bench and imaging measurements. Results The addition of DC currents to the 32-channel RF array is achieved with minimal disruption of the RF performance and/or negative side effects such as conductor heating or mechanical torques. The shimming results agree well with simulations and show performance superior to third-order spherical harmonic (SH) shimming. Imaging tests show the ability to reduce the standard frontal lobe susceptibility-induced fields and improve echo planar imaging geometric distortion. The simulation of 64- and 128-channel brain arrays suggest that even further shimming improvement is possible (equivalent to up to 6th-order SH shim coils). Conclusion Including user-controlled shim currents on the loops of a conventional highly parallel brain array coil is feasible with modest current levels and produces improved B0 shimming performance over standard second-order SH shimming. PMID:25689977

  12. Current Evidence Regarding the Treatment of Pediatric Lumbar Spondylolisthesis: A Report From the Scoliosis Research Society Evidence Based Medicine Committee.

    PubMed

    Crawford, Charles H; Larson, A Noelle; Gates, Marilyn; Bess, R Shay; Guillaume, Tenner J; Kim, Han Jo; Oetgen, Matthew E; Ledonio, Charles G; Sanders, James; Burton, Douglas C

    2017-09-01

    Structured literature review. The Scoliosis Research Society requested an assessment of the current state of peer-reviewed evidence regarding pediatric lumbar spondylolisthesis to identify what is known and what research remains essential to further understanding. Pediatric lumbar spondylolisthesis is common, yet no formal synthesis of the published literature regarding treatment has been previously performed. A comprehensive literature search was performed. From 6600 initial citations with abstract, 663 articles underwent full-text review. The best available evidence regarding surgical and medical/interventional treatment was provided by 51 studies. None of the studies were graded Level I or II evidence. Eighteen of the studies were Level III, representing the current best available evidence. Thirty-three of the studies were Level IV. Although studies suggest a benign course for "low grade" (<50% slip) isthmic spondylolisthesis, extensive literature suggests that a substantial number of patients present for treatment with pain and activity limitations. Pain resolution and return to activity is common with both medical/interventional and operative treatment. The role of medical/interventional bracing is not well established. Uninstrumented posterolateral fusion has been reported to produce good clinical results, but concerns regarding nonunion exist. Risk of slip progression is a specific concern in the "high grade" or dysplastic type. Although medical/interventional observation has been reported to be reasonable in a small series of asymptomatic high-grade slip patients, surgical treatment is commonly recommended to prevent progression. There is Level III evidence that instrumentation and reduction lowers the risk of nonunion, and that circumferential fusion is superior to posterior-only or anterior-only fusion. There is Level III evidence that patients with a higher slip angle are more likely to fail medical/interventional treatment of high-grade spondylolisthesis. The current "best available" evidence to guide the treatment of pediatric spondylolisthesis is presented. Level III; review of Level III studies. Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  13. Leadership and Small Firm Performance: The Moderating Effects of Demographic Characteristics

    ERIC Educational Resources Information Center

    Flanigan, Rod L.; Bishop, Jacob L.; Brachle, Ben J.; Winn, Bradley A.

    2017-01-01

    The present study builds on extant leadership literature by examining the role demographic variables (including age, tenure as a leader at the current company, experience in the industry, and level of education) play as moderating effects on the relationship between leadership style and small business financial performance in the national…

  14. Coaching as a Performance Improvement Tool at School

    ERIC Educational Resources Information Center

    Yirci, Ramazan; Karakose, Turgut; Kocabas, Ibrahim

    2016-01-01

    The purpose of this study is to examine the current literature and have an insight about coaching as a performance improvement tool at school. In today's world, schools have to survive and keep their organizational success in the highest level because of the high expectations from school stakeholders. Taking place in such a fierce competitive…

  15. Dynamic Assessment of Phonological Awareness for Children with Speech Sound Disorders

    ERIC Educational Resources Information Center

    Gillam, Sandra Laing; Ford, Mikenzi Bentley

    2012-01-01

    The current study was designed to examine the relationships between performance on a nonverbal phoneme deletion task administered in a dynamic assessment format with performance on measures of phoneme deletion, word-level reading, and speech sound production that required verbal responses for school-age children with speech sound disorders (SSDs).…

  16. Accounting for the Performance of Students With Disabilities on Statewide Assessments

    ERIC Educational Resources Information Center

    Malmgren, Kimber W.; McLaughlin, Margaret J.; Nolet, Victor

    2005-01-01

    The current study investigates school-level factors that affect the performance of students with disabilities on statewide assessments. Data were collected as part of a larger study examining the effects of education policy reform on students with disabilities. Statewide assessment data for students with disabilities from 2 school districts within…

  17. The Development of MST Test Information for the Prediction of Test Performances

    ERIC Educational Resources Information Center

    Park, Ryoungsun; Kim, Jiseon; Chung, Hyewon; Dodd, Barbara G.

    2017-01-01

    The current study proposes novel methods to predict multistage testing (MST) performance without conducting simulations. This method, called MST test information, is based on analytic derivation of standard errors of ability estimates across theta levels. We compared standard errors derived analytically to the simulation results to demonstrate the…

  18. Mapping Health Data: Improved Privacy Protection With Donut Method Geomasking

    PubMed Central

    Hampton, Kristen H.; Fitch, Molly K.; Allshouse, William B.; Doherty, Irene A.; Gesink, Dionne C.; Leone, Peter A.; Serre, Marc L.; Miller, William C.

    2010-01-01

    A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest. PMID:20817785

  19. Mapping health data: improved privacy protection with donut method geomasking.

    PubMed

    Hampton, Kristen H; Fitch, Molly K; Allshouse, William B; Doherty, Irene A; Gesink, Dionne C; Leone, Peter A; Serre, Marc L; Miller, William C

    2010-11-01

    A major challenge in mapping health data is protecting patient privacy while maintaining the spatial resolution necessary for spatial surveillance and outbreak identification. A new adaptive geomasking technique, referred to as the donut method, extends current methods of random displacement by ensuring a user-defined minimum level of geoprivacy. In donut method geomasking, each geocoded address is relocated in a random direction by at least a minimum distance, but less than a maximum distance. The authors compared the donut method with current methods of random perturbation and aggregation regarding measures of privacy protection and cluster detection performance by masking multiple disease field simulations under a range of parameters. Both the donut method and random perturbation performed better than aggregation in cluster detection measures. The performance of the donut method in geoprivacy measures was at least 42.7% higher and in cluster detection measures was less than 4.8% lower than that of random perturbation. Results show that the donut method provides a consistently higher level of privacy protection with a minimal decrease in cluster detection performance, especially in areas where the risk to individual geoprivacy is greatest.

  20. Reducing Current Spread using Current Focusing in Cochlear Implant Users

    PubMed Central

    Landsberger, David M.; Padilla, Monica; Srinivasan, Arthi G.

    2012-01-01

    Cochlear implant performance in difficult listening situations is limited by channel interactions. It is known that partial tripolar (PTP) stimulation reduces the spread of excitation (SOE). However, the greater the degree of current focusing, the greater the absolute current required to maintain a fixed loudness. As current increases, so does SOE. In experiment 1, the SOE for equally loud stimuli with different degrees of current focusing is measured via a forward-masking procedure. Results suggest that at a fixed loudness, some but not all patients have a reduced SOE with PTP stimulation. Therefore, it seems likely that a PTP speech processing strategy could improve spectral resolution for only those patients with a reduced SOE. In experiment 2, the ability to discriminate different levels of current focusing was measured. In experiment 3, patients subjectively scaled verbal descriptors of stimuli of various levels of current focusing. Both discrimination and scaling of verbal descriptors correlated well with SOE reduction, suggesting that either technique have the potential to be used clinically to quickly predict which patients would receive benefit from a current focusing strategy. PMID:22230370

  1. DistributedFBA.jl: High-level, high-performance flux balance analysis in Julia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heirendt, Laurent; Thiele, Ines; Fleming, Ronan M. T.

    Flux balance analysis and its variants are widely used methods for predicting steady-state reaction rates in biochemical reaction networks. The exploration of high dimensional networks with such methods is currently hampered by software performance limitations. DistributedFBA.jl is a high-level, high-performance, open-source implementation of flux balance analysis in Julia. It is tailored to solve multiple flux balance analyses on a subset or all the reactions of large and huge-scale networks, on any number of threads or nodes. DistributedFBA.jl is a high-level, high-performance, open-source implementation of flux balance analysis in Julia. It is tailored to solve multiple flux balance analyses on amore » subset or all the reactions of large and huge-scale networks, on any number of threads or nodes.« less

  2. DistributedFBA.jl: High-level, high-performance flux balance analysis in Julia

    DOE PAGES

    Heirendt, Laurent; Thiele, Ines; Fleming, Ronan M. T.

    2017-01-16

    Flux balance analysis and its variants are widely used methods for predicting steady-state reaction rates in biochemical reaction networks. The exploration of high dimensional networks with such methods is currently hampered by software performance limitations. DistributedFBA.jl is a high-level, high-performance, open-source implementation of flux balance analysis in Julia. It is tailored to solve multiple flux balance analyses on a subset or all the reactions of large and huge-scale networks, on any number of threads or nodes. DistributedFBA.jl is a high-level, high-performance, open-source implementation of flux balance analysis in Julia. It is tailored to solve multiple flux balance analyses on amore » subset or all the reactions of large and huge-scale networks, on any number of threads or nodes.« less

  3. Superior characteristics of microscale light emitting diodes through tightly lateral oxide-confined scheme

    NASA Astrophysics Data System (ADS)

    Huang, Shen-Che; Li, Heng; Zhang, Zhe-Han; Chen, Hsiang; Wang, Shing-Chung; Lu, Tien-Chang

    2017-01-01

    We report on the design of the geometry and chip size-controlled structures of microscale light-emitting diodes (micro-LEDs) with a shallow-etched oxide-refilled current aperture and their performance. The proposed structure, which combines an indium-tin-oxide layer and an oxide-confined aperture, exhibited not only uniform current distribution but also remarkably tight current confinement. An extremely high injection level of more than 90 kA/cm2 was achieved in the micro-LED with a 5-μm aperture. Current spreading and the droop mechanism in the investigated devices were characterized through electroluminescence measurements, optical microscopy, and beam-view imaging. Furthermore, we utilized the β-model and S-model to elucidate current crowding and the efficiency droop phenomenon in the investigated micro-LEDs. The luminescence results evidenced the highly favorable performance of the fabricated micro-LEDs, which is a result of their more uniform current spreading and lower junction temperature relative to conventional LEDs. Moreover, the maximum endured current density could be further increased by reducing the aperture size of the micro-LEDs. The proposed design, which is expected to be beneficial for the development of high-performance array-based micro-LEDs, is practicable through current state-of-the-art processing techniques.

  4. Fast Timing for High-Rate Environments with Micromegas

    NASA Astrophysics Data System (ADS)

    Papaevangelou, Thomas; Desforge, Daniel; Ferrer-Ribas, Esther; Giomataris, Ioannis; Godinot, Cyprien; Diaz, Diego Gonzalez; Gustavsson, Thomas; Kebbiri, Mariam; Oliveri, Eraldo; Resnati, Filippo; Ropelewski, Leszek; Tsiledakis, Georgios; Veenhof, Rob; White, Sebastian

    2018-02-01

    The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate aMicromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkovradiator front window, which produces sufficient UV photons to convert the ˜100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ˜50 primary photoelectrons, using a bulk Micromegas readout.

  5. Relative performance analysis of IR FPA technologies from the perspective of system level performance

    NASA Astrophysics Data System (ADS)

    Haran, Terence L.; James, J. Christopher; Cincotta, Tomas E.

    2017-08-01

    The majority of high performance infrared systems today utilize FPAs composed of intrinsic direct bandgap semiconductor photon detectors such as MCT or InSb. Quantum well detector technologies such as QWIPs, QDIPs, and SLS photodetectors are potentially lower cost alternatives to MCT and InSb, but the relative performance of these technologies has not been sufficiently high to allow widespread adoption outside of a handful of applications. While detectors are often evaluated using figures of merit such as NETD or D∗, these metrics, which include many underlying aspects such as spectral quantum efficiency, dark current, well size, MTF, and array response uniformity, may be far removed from the performance metrics used to judge performance of a system in an operationally relevant scenario. True comparisons of performance for various detector technologies from the perspective of end-to-end system performance have rarely been conducted, especially considering the rapid progress of the newer quantum well technologies. System level models such as the US Army's Night Vision Integrated Performance Model (NV-IPM) can calculate image contrast and spatial frequency content using data from the target/background, intervening atmosphere, and system components. This paper includes results from a performance parameter sensitivity analysis using NV-IPM to determine the relative importance of various FPA performance parameters to the overall performance of a long range imaging system. Parameters included are: QE, dark current density, quantum well capacity, downstream readout noise, well fill, image frame rate, frame averaging, and residual fixed pattern noise. The state-of-the art for XBn, QWIP, and SLS detector technologies operating in the MWIR and LWIR bands will be surveyed to assess performance of quantum structures compared to MCT and InSb. The intent is to provide a comprehensive assessment of quantum detector performance and to identify areas where increased research could provide the most benefit to overall system level performance.

  6. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors.

    PubMed

    Giusi, G; Giordano, O; Scandurra, G; Rapisarda, M; Calvi, S; Ciofi, C

    2016-04-01

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz(1/2), while DC performances are limited only by the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.

  7. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giusi, G.; Giordano, O.; Scandurra, G.

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz{sup 1/2}, while DC performances are limited only bymore » the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.« less

  8. The relationship between chiropractor required and current level of business knowledge.

    PubMed

    Ciolfi, Michael Anthony; Kasen, Patsy Anne

    2017-01-01

    Chiropractors frequently practice within health care systems requiring the business acumen of an entrepreneur. However, some chiropractors do not know the relationship between the level of business knowledge required for practice success and their current level of business knowledge. The purpose of this quantitative study was to examine the relationship between chiropractors' perceived level of business knowledge required and their perceived level of current business knowledge. Two hundred and seventy-four participants completed an online survey (Health Care Training and Education Needs Survey) which included eight key business items. Participants rated the level of perceived business knowledge required (Part I) and their current perceived level of knowledge (Part II) for the same eight items. Data was collected from November 27, 2013 to December 18, 2013. Data were analyzed using Spearman's ranked correlation to determine the statistically significant relationships for the perceived level of knowledge required and the perceived current level of knowledge for each of the paired eight items from Parts I and II of the survey. Wilcoxon Signed Ranks Tests were performed to determine the statistical difference between the paired items. The results of Spearman's correlation testing indicated a statistically significant ( p < 0.01) positive correlation for the perceived level of knowledge required and perceived current level of knowledge for six variables: (a) organizational behavior, (b) strategic management, (c) marketing, (d) legal and ethical, (e) managerial decisions, and (f) operations. Wilcoxon Signed Ranks testing indicated a significant difference for three paired items: strategic management; marketing and; legal and ethical. The results suggest that relationships exist for the majority of business items (6 of 8) however a statistically difference was demonstrated in only three of the paired business items. The implications of this study for social change include the potential to improve chiropractors' business knowledge and skills, enable practice success, enhance health services delivery and positively influence the profession as a viable career.

  9. Screening for Elevated Blood Lead Levels in Children: Assessment of Criteria and a Proposal for New Ones in France

    PubMed Central

    Etchevers, Anne; Glorennec, Philippe; Le Strat, Yann; Lecoffre, Camille; Bretin, Philippe; Le Tertre, Alain

    2015-01-01

    The decline in children’s Blood Lead Levels (BLL) raises questions about the ability of current lead poisoning screening criteria to identify those children most exposed. The objectives of the study were to evaluate the performance of current screening criteria in identifying children with blood lead levels higher than 50 µg/L in France, and to propose new criteria. Data from a national French survey, conducted among 3831 children aged 6 months to 6 years in 2008–2009 were used. The sensitivity and specificity of the current criteria in predicting blood lead levels higher than or equal to 50 µg/L were evaluated. Two predictive models of BLL above 44 µg/L (for lack of sufficient sample size at 50 µg/L) were built: the first using current criteria, and the second using newly identified risk factors. For each model, performance was studied by calculating the area under the ROC (Receiver Operating Characteristic) curve. The sensitivity of current criteria for detecting BLL higher than or equal to 50 µg/L was 0.51 (0.26; 0.75) and specificity was 0.66 (0.62; 0.70). The new model included the following criteria: foreign child newly arrived in France, mother born abroad, consumption of tap water in the presence of lead pipes, pre-1949 housing, period of construction of housing unknown, presence of peeling paint, parental smoking at home, occupancy rates for housing and child’s address in a cadastral municipality or census block comprising more than 6% of housing that is potentially unfit and built pre-1949. The area under the ROC curve was 0.86 for the new model, versus 0.76 for the current one. The lead poisoning screening criteria should be updated. The risk of industrial, occupational and hobby-related exposure could not be assessed in this study, but should be kept as screening criteria. PMID:26633457

  10. Measuring Information Security Performance with 10 by 10 Model for Holistic State Evaluation.

    PubMed

    Bernik, Igor; Prislan, Kaja

    Organizations should measure their information security performance if they wish to take the right decisions and develop it in line with their security needs. Since the measurement of information security is generally underdeveloped in practice and many organizations find the existing recommendations too complex, the paper presents a solution in the form of a 10 by 10 information security performance measurement model. The model-ISP 10×10M is composed of ten critical success factors, 100 key performance indicators and 6 performance levels. Its content was devised on the basis of findings presented in the current research studies and standards, while its structure results from an empirical research conducted among information security professionals from Slovenia. Results of the study show that a high level of information security performance is mostly dependent on measures aimed at managing information risks, employees and information sources, while formal and environmental factors have a lesser impact. Experts believe that information security should evolve systematically, where it's recommended that beginning steps include technical, logical and physical security controls, while advanced activities should relate predominantly strategic management activities. By applying the proposed model, organizations are able to determine the actual level of information security performance based on the weighted indexing technique. In this manner they identify the measures they ought to develop in order to improve the current situation. The ISP 10×10M is a useful tool for conducting internal system evaluations and decision-making. It may also be applied to a larger sample of organizations in order to determine the general state-of-play for research purposes.

  11. Identifying poor performance among doctors in NHS organizations.

    PubMed

    Locke, Rachel; Scallan, Samantha; Leach, Camilla; Rickenbach, Mark

    2013-10-01

    To account for the means by which poor performance among career doctors is identified by National Health Service organizations, whether the tools are considered effective and how these processes may be strengthened in the light of revalidation and the requirement for doctors to demonstrate their fitness to practice. This study sought to look beyond the 'doctor as individual'; as well as considering the typical approaches to managing the practice of an individual, the systems within which the doctor is working were reviewed, as these are also relevant to standards of performance. A qualitative review was undertaken consisting of a literature review of current practice, a policy review of current documentation from 15 trusts in one deanery locality, and 14 semi-structured interviews with respondents with an overview of processes in use. The framework for the analysis of the data considered tools at three levels: individual, team and organizational. Tools are, in the main, reactive--with an individual focus. They rely on colleagues and others to speak out, so their effectiveness is hindered by a reluctance to do so. Tools can lack an evidence base for their use, and there is limited linking of data across contexts and tools. There is more work to be done in evaluating current tools and developing stronger processes. Linkage between data sources needs to be improved and proactive tools at the organizational level need further development to help with the early identification of performance issues. This would also assist in balancing a wider systems approach with a current over emphasis on individual doctors. © 2012 John Wiley & Sons Ltd.

  12. Effectiveness of diadynamic currents and transcutaneous electrical nerve stimulation in disc disease lumbar part of spine.

    PubMed

    Ratajczak, Barbara; Hawrylak, Arletta; Demidaś, Aneta; Kuciel-Lewandowska, Jadwiga; Boerner, Ewa

    2011-01-01

    Back pain has multi-factorial etiology and is modified by environmental influences, character of work, and individual predispositions. The aim of this study was to compare the efficiency of analgesic DD current therapy and TENS in low back discopathy. Eighty patients (age, 45-60 years) with diagnosed low back pain syndrome due to discopathy were subjected to therapy. In the first group (DD) of 40 people, DD current therapy was applied. In the second group (TENS) of 40 people, TENS was applied. The third group of 40 people was a control group in which a functional fitness test was performed for comparison purposes. The control group was in this case an equivalent to a norm. Before the beginning and on the completion of therapy in all patients, a pain level measurement and functional fitness test were performed. On the basis of research conducted it was stated that both therapies reduce pain level effectively. Obtained analyzed results conclude that both therapies applied have an analgesic effect. DD current and TENS therapies in low back discopathy have an analgesic impact and improve functional fitness. The applied therapies have a comparable impact on researched parameters.

  13. CORRELATING NEUROBEHAVIORAL PERFORMANCE WITH BIOMARKERS OF ORGANOPHOSPHOROUS PESTICIDE EXPOSURE

    PubMed Central

    Rohlman, Diane S.; Anger, W Kent; Lein, Pamela J

    2011-01-01

    There is compelling evidence that adverse neurobehavioral effects are associated with occupational organophosphorous pesticide (OP) exposure in humans. Behavioral studies of pesticide applicators, greenhouse workers, agricultural workers and farm residents exposed repeatedly over months or years to low levels of OPs reveal a relatively consistent pattern of neurobehavioral deficits. However, only two studies have demonstrated a link between neurobehavioral performance and current biomarkers of OP exposure including blood cholinesterase (ChE) activity and urinary levels of OP metabolites. A variety of reasons may explain why so few studies have reported such correlations, including differing individual and group exposure histories, differing methodologies for assessing behavior and exposure, and lack of a reliable index of exposure. Alternatively, these data may suggest that current biomarkers (ChE, urine metabolites) are neither predictive nor diagnostic of the neurobehavioral effects of chronic OP pesticide exposures. This review focuses on the evidence that neurobehavioral performance deficits are associated with occupational OP pesticide exposure and concludes that research needs to return to the basics and rigorously test the relationships between neurobehavioral performance and both current (ChE and urine metabolites) and novel (eg, inflammation and oxidative stress) biomarkers using human and animal models. The results of such studies are critically important because OP pesticides are widely and extensively used throughout the world, including situations where exposure controls and personal protective equipment are not routinely used. PMID:21182866

  14. Safety Assurance in NextGen

    NASA Technical Reports Server (NTRS)

    HarrisonFleming, Cody; Spencer, Melissa; Leveson, Nancy; Wilkinson, Chris

    2012-01-01

    The generation of minimum operational, safety, performance, and interoperability requirements is an important aspect of safely integrating new NextGen components into the Communication Navigation Surveillance and Air Traffic Management (CNS/ATM) system. These requirements are used as part of the implementation and approval processes. In addition, they provide guidance to determine the levels of design assurance and performance that are needed for each element of the new NextGen procedures, including aircraft, operator, and Air Navigation and Service Provider. Using the enhanced Airborne Traffic Situational Awareness for InTrail Procedure (ATSA-ITP) as an example, this report describes some limitations of the current process used for generating safety requirements and levels of required design assurance. An alternative process is described, as well as the argument for why the alternative can generate more comprehensive requirements and greater safety assurance than the current approach.

  15. Solar power generation system for reducing leakage current

    NASA Astrophysics Data System (ADS)

    Wu, Jinn-Chang; Jou, Hurng-Liahng; Hung, Chih-Yi

    2018-04-01

    This paper proposes a transformer-less multi-level solar power generation system. This solar power generation system is composed of a solar cell array, a boost power converter, an isolation switch set and a full-bridge inverter. A unipolar pulse-width modulation (PWM) strategy is used in the full-bridge inverter to attenuate the output ripple current. Circuit isolation is accomplished by integrating the isolation switch set between the solar cell array and the utility, to suppress the leakage current. The isolation switch set also determines the DC bus voltage for the full-bridge inverter connecting to the solar cell array or the output of the boost power converter. Accordingly, the proposed transformer-less multi-level solar power generation system generates a five-level voltage, and the partial power of the solar cell array is also converted to AC power using only the full-bridge inverter, so the power efficiency is increased. A prototype is developed to validate the performance of the proposed transformer-less multi-level solar power generation system.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The papers in this document comprise the proceedings of the Department of Energy's Twelfth Annual Low-Level Radioactive Waste Management Conference, which was held in Chicago, Illinois, on August 28 and 29, 1990. General subjects addressed during the conference included: mixed waste, low-level radioactive waste tracking and transportation, public involvement, performance assessment, waste stabilization, financial assurance, waste minimization, licensing and environmental documentation, below-regulatory-concern waste, low-level radioactive waste temporary storage, current challenges, and challenges beyond 1990.

  17. Evidence of transcranial direct current stimulation-generated electric fields at subthalamic level in human brain in vivo.

    PubMed

    Chhatbar, Pratik Y; Kautz, Steven A; Takacs, Istvan; Rowland, Nathan C; Revuelta, Gonzalo J; George, Mark S; Bikson, Marom; Feng, Wuwei

    2018-03-13

    Transcranial direct current stimulation (tDCS) is a promising brain modulation technique for several disease conditions. With this technique, some portion of the current penetrates through the scalp to the cortex and modulates cortical excitability, but a recent human cadaver study questions the amount. This insufficient intracerebral penetration of currents may partially explain the inconsistent and mixed results in tDCS studies to date. Experimental validation of a transcranial alternating current stimulation-generated electric field (EF) in vivo has been performed on the cortical (using electrocorticography, ECoG, electrodes), subcortical (using stereo electroencephalography, SEEG, electrodes) and deeper thalamic/subthalamic levels (using DBS electrodes). However, tDCS-generated EF measurements have never been attempted. We aimed to demonstrate that tDCS generates biologically relevant EF as deep as the subthalamic level in vivo. Patients with movement disorders who have implanted deep brain stimulation (DBS) electrodes serve as a natural experimental model for thalamic/subthalamic recordings of tDCS-generated EF. We measured voltage changes from DBS electrodes and body resistance from tDCS electrodes in three subjects while applying direct current to the scalp at 2 mA and 4 mA over two tDCS montages. Voltage changes at the level of deep nuclei changed proportionally with the level of applied current and varied with different tDCS montages. Our findings suggest that scalp-applied tDCS generates biologically relevant EF. Incorporation of these experimental results may improve finite element analysis (FEA)-based models. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Current and sea-level signals in periplatform ooze (Neogene, Maldives, Indian Ocean)

    NASA Astrophysics Data System (ADS)

    Betzler, Christian; Lüdmann, Thomas; Hübscher, Christian; Fürstenau, Jörn

    2013-05-01

    Periplatform ooze is an admixture of pelagic carbonate and sediment derived from neritic carbonate platforms. Compositional variations of periplatform ooze allow the reconstruction of past sea-level changes. Periplatform ooze formed during sea-level highstands is finer grained and richer in aragonite through the elevated input of material from the flooded platform compared to periplatform ooze formed during the episodes of lowered sea level. In many cases, however, the sea floor around carbonate platforms is subjected to bottom currents which are expected to affect sediment composition, i.e. through winnowing of the fine fraction. The interaction of sea-level driven highstand shedding and current impact on the formation of periplatform ooze has hitherto not been analyzed. To test if a sea-level driven input signal in periplatform ooze is influenced or even distorted by changing current activity, an integrated study using seismic, hydroacoustic and sedimentological data has been performed on periplatform ooze deposited in the Inner Sea of the Maldives. The Miocene to Pleistocene succession of drift deposits is subdivided into nine units; limits of seismostratigraphic units correspond to changes or turnarounds in grain size trends in cores recovered at ODP Site 716 and NEOMA Site 1143. For the Pleistocene it can be shown how changes in grain size occur in concert with sea-level changes and changes of the monsoonal system, which is thought to be a major driver of bottom currents in the Maldives. A clear highstand shedding pattern only appears in the data at a time of relaxation of monsoonal strength during the last 315 ky. Results imply (1) that drift sediments provide a potential target for analyzing past changes in oceanic currents and (2) that the ooze composition bears a mixed signal of input and physical winnowing at the sea floor.

  19. LLMapReduce: Multi-Level Map-Reduce for High Performance Data Analysis

    DTIC Science & Technology

    2016-05-23

    LLMapReduce works with several schedulers such as SLURM, Grid Engine and LSF. Keywords—LLMapReduce; map-reduce; performance; scheduler; Grid Engine ...SLURM; LSF I. INTRODUCTION Large scale computing is currently dominated by four ecosystems: supercomputing, database, enterprise , and big data [1...interconnects [6]), High performance math libraries (e.g., BLAS [7, 8], LAPACK [9], ScaLAPACK [10]) designed to exploit special processing hardware, High

  20. The relationship between health and cognitive functioning in a sample of elderly people in the community.

    PubMed

    Christensen, H; Jorm, A F; Henderson, A S; Mackinnon, A J; Korten, A E; Scott, L R

    1994-05-01

    The association between health status and cognitive performance was examined in a sample of 708 community dwelling elderly people aged 70 years or over. Cognitive performance declined significantly across the age groups 70-74, 75-79, 80-84, and 85-89 years on the Mini-Mental State Examination and on measures of fluid intelligence and memory, but not on measures of crystallized intelligence. Health status declined significantly across age for five of 49 past and current medical conditions, for measures of Activities of Daily Living (ADL) and for systolic blood pressure, but did not decline significantly for global self-ratings of health, diastolic blood pressure or reports of smoking. Weak but significant correlations between health and cognitive performance were found for self-reported global ratings of health and for self-reports of some physical symptoms but not for diastolic or systolic blood pressure, or for many other physical conditions. Both self- and informant-based ratings of ADL correlated with cognitive performance. Age differences remained after cognitive performance was adjusted for health variables such as ADL, self-ratings of health and current health problems. It is concluded that, at the population level, lower levels of cognitive performance in community-dwelling elderly subjects are not strongly mediated by ill health.

  1. Current fluctuations in quantum absorption refrigerators

    NASA Astrophysics Data System (ADS)

    Segal, Dvira

    2018-05-01

    Absorption refrigerators transfer thermal energy from a cold bath to a hot bath without input power by utilizing heat from an additional "work" reservoir. Particularly interesting is a three-level design for a quantum absorption refrigerator, which can be optimized to reach the maximal (Carnot) cooling efficiency. Previous studies of three-level chillers focused on the behavior of the averaged cooling current. Here, we go beyond that and study the full counting statistics of heat exchange in a three-level chiller model. We explain how to obtain the complete cumulant generating function of the refrigerator in a steady state, then derive a partial cumulant generating function, which yields closed-form expressions for both the averaged cooling current and its noise. Our analytical results and simulations are beneficial for the design of nanoscale engines and cooling systems far from equilibrium, with their performance optimized according to different criteria, efficiency, power, fluctuations, and dissipation.

  2. The Current Collapse in AlGaN/GaN High-Electron Mobility Transistors Can Originate from the Energy Relaxation of Channel Electrons?

    PubMed Central

    Mao, Ling-Feng; Ning, Huan-Sheng; Wang, Jin-Yan

    2015-01-01

    Influence of the energy relaxation of the channel electrons on the performance of AlGaN/GaN high-electron mobility transistors (HEMTs) has been investigated using self-consistent solution to the coupled Schrödinger equation and Poisson equation. The first quantized energy level in the inversion layer rises and the average channel electron density decreases when the channel electric field increases from 20 kV/cm to 120 kV/cm. This research also demonstrates that the energy relaxation of the channel electrons can lead to current collapse and suggests that the energy relaxation should be considered in modeling the performance of AlGaN/GaN HEMTs such as, the gate leakage current, threshold voltage, source-drain current, capacitance-voltage curve, etc. PMID:26039589

  3. The Current Collapse in AlGaN/GaN High-Electron Mobility Transistors Can Originate from the Energy Relaxation of Channel Electrons?

    PubMed

    Mao, Ling-Feng; Ning, Huan-Sheng; Wang, Jin-Yan

    2015-01-01

    Influence of the energy relaxation of the channel electrons on the performance of AlGaN/GaN high-electron mobility transistors (HEMTs) has been investigated using self-consistent solution to the coupled Schrödinger equation and Poisson equation. The first quantized energy level in the inversion layer rises and the average channel electron density decreases when the channel electric field increases from 20 kV/cm to 120 kV/cm. This research also demonstrates that the energy relaxation of the channel electrons can lead to current collapse and suggests that the energy relaxation should be considered in modeling the performance of AlGaN/GaN HEMTs such as, the gate leakage current, threshold voltage, source-drain current, capacitance-voltage curve, etc.

  4. Measuring performance in virtual reality phacoemulsification surgery

    NASA Astrophysics Data System (ADS)

    Söderberg, Per; Laurell, Carl-Gustaf; Simawi, Wamidh; Skarman, Eva; Nordh, Leif; Nordqvist, Per

    2008-02-01

    We have developed a virtual reality (VR) simulator for phacoemulsification surgery. The current work aimed at developing a relative performance index that characterizes the performance of an individual trainee. We recorded measurements of 28 response variables during three iterated surgical sessions in 9 experienced cataract surgeons, separately for the sculpting phase and the evacuation phase of phacoemulsification surgery and compared their outcome to that of a reference group of naive trainees. We defined an individual overall performance index, an individual class specific performance index and an individual variable specific performance index. We found that on an average the experienced surgeons performed at a lower level than a reference group of naive trainees but that this was particularly attributed to a few surgeons. When their overall performance index was further analyzed as class specific performance index and variable specific performance index it was found that the low level performance was attributed to a behavior that is acceptable for an experienced surgeon but not for a naive trainee. It was concluded that relative performance indices should use a reference group that corresponds to the measured individual since the definition of optimal surgery may vary among trainee groups depending on their level of experience.

  5. Grinding and classification of pine bark for use as plywood adhesive filler

    Treesearch

    Thomas L. Eberhardt; Karen G. Reed

    2005-01-01

    Prior efforts to incorporate bark or bark extracts into composites have met with only limited success because of poor performance relative to existing products and/or economic barriers stemming from high levels of processing. We are currently investigating applications for southern yellow pine (SYP) bark that require intermediate levels of processing, one being the use...

  6. THE DETERMINATION OF MERCURY AND MULTIPLE METALS IN DIETARY MATRICES USING DIRECT INJECTION NEBULIZATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (DIN-ICP/MS)

    EPA Science Inventory

    Mercury (Hg) is a Persistent Bioaccumulative Toxin. Currently, low-level mercury (Hg) and low-level multiple-metals analyses require separate methods. Due to the high costs of performing both types of analyses, research planners often have to choose one or the other. For examp...

  7. Uprated OMS Engine Status-Sea Level Testing Results

    NASA Technical Reports Server (NTRS)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  8. Advanced photovoltaic solar array - Design and performance

    NASA Technical Reports Server (NTRS)

    Kurland, Richard; Stella, Paul

    1992-01-01

    This paper reports on the development of an ultralightweight flexible blanket, flatpack, foldout solar array design that can provide 3- to 4-fold improvement on specific power performance of current rigid panel arrays and a factor of two improvement over a first-generation flexible blanket array developed as a forerunner to the Space Station Freedom array. To date a prototype wing has been built with a projected specific power performance of about 138 W/kg at beginning-of-life (BOL) and 93 W/kg end-of-life (EOL) at 12 kW (BOL) for a 10-year geosynchronous (GEO) mission. The prototype wing hardware has been subjected to a series of system-level tests to demonstrate design feasibility. The design of the array is summarized. The major trade studies that led to the selection of the baseline design are discussed. Key system-level and component-level testing are described. Array-level performance projections are presented as a function of existing and advanced solar array component technology for various mission applications.

  9. The Impact of Federal Public Policy on Curriculum and Instruction for Students with Disabilities in the General Classroom

    ERIC Educational Resources Information Center

    Hardman, Michael L.; Dawson, Shirley

    2008-01-01

    The promise that all children will achieve higher levels of academic performance is the foundation of the current educational reform movement. Standards-based reform began with financial assistance to the states for the development of content and performance standards, improved teacher quality, and increased school accountability. The reform…

  10. Teacher and Administrator Perceptions of In-School Suspension Programs on Changing Student Behavior and Academic Success in Schools

    ERIC Educational Resources Information Center

    Rimes, John Scott

    2012-01-01

    This study was performed to examine the perception of teachers, in-school suspension (ISS) staff, and administrators on the effectiveness of the in-school suspension program in changing students' behavior and academic success at various schools with different performance levels according the current Mississippi Accountability Model. The 32 schools…

  11. More than the "X" Factor! A Longitudinal Investigation of the Psychological Characteristics of Developing Excellence in Musical Development

    ERIC Educational Resources Information Center

    Macnamara, Aine; Collins, Dave

    2009-01-01

    Current findings in talent identification and development research have acknowledged that potential for future performance cannot be identified from single evaluations of performance or anthropometric factors (e.g. Abbott and Collins 2004). Recognising the role of psychological characteristics at elite levels, it is pertinent to consider the role…

  12. Perfectionism, Performance, and State Positive Affect and Negative Affect after a Classroom Test

    ERIC Educational Resources Information Center

    Flett, Gordon L.; Blankstein, Kirk R.; Hewitt, Paul L.

    2009-01-01

    The current study examined the associations among trait dimensions of perfectionism, test performance, and levels of positive and negative affect after taking a test. A sample of 92 female university students completed the Multidimensional Perfectionism Scale one week prior to an actual class test. Measures of positive affect and negative affect…

  13. Pinpointing the Deficit in Executive Functions in Adolescents with Dyslexia Performing the Wisconsin Card Sorting Test: An ERP Study

    ERIC Educational Resources Information Center

    Horowitz-Kraus, Tzipi

    2014-01-01

    Adolescents with dyslexia exhibit well-established impairments in executive abilities. The Wisconsin card sorting test (WCST) is an executive test that yields surprisingly inconsistent results with this population. The current study aimed to shed light on the contradictory findings in the literature regarding the performance levels by individuals…

  14. A Comparison of the Developmental Experiences of Elite and Sub-Elite Swimmers: Similar Developmental Histories Can Lead to Differences in Performance Level

    ERIC Educational Resources Information Center

    Johnson, Michael B.; Tenenbaum, Gershon; Edmonds, William A.; Castillo, Yvonne

    2008-01-01

    The current study fills a void in the literature that investigates the factors required for elite athlete development. Previous studies have (a) illustrated psychological and physiological differences between elites and non-elites; "or" (b) described the psychological and physiological developmental experiences of elite performers. The…

  15. Device and circuit-level performance of carbon nanotube field-effect transistor with benchmarking against a nano-MOSFET.

    PubMed

    Tan, Michael Loong Peng; Lentaris, Georgios; Amaratunga Aj, Gehan

    2012-08-19

    The performance of a semiconducting carbon nanotube (CNT) is assessed and tabulated for parameters against those of a metal-oxide-semiconductor field-effect transistor (MOSFET). Both CNT and MOSFET models considered agree well with the trends in the available experimental data. The results obtained show that nanotubes can significantly reduce the drain-induced barrier lowering effect and subthreshold swing in silicon channel replacement while sustaining smaller channel area at higher current density. Performance metrics of both devices such as current drive strength, current on-off ratio (Ion/Ioff), energy-delay product, and power-delay product for logic gates, namely NAND and NOR, are presented. Design rules used for carbon nanotube field-effect transistors (CNTFETs) are compatible with the 45-nm MOSFET technology. The parasitics associated with interconnects are also incorporated in the model. Interconnects can affect the propagation delay in a CNTFET. Smaller length interconnects result in higher cutoff frequency.

  16. Space shuttle hypergolic bipropellant RCS engine design study, Bell model 8701

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A research program was conducted to define the level of the current technology base for reaction control system rocket engines suitable for space shuttle applications. The project consisted of engine analyses, design, fabrication, and tests. The specific objectives are: (1) extrapolating current engine design experience to design of an RCS engine with required safety, reliability, performance, and operational capability, (2) demonstration of multiple reuse capability, and (3) identification of current design and technology deficiencies and critical areas for future effort.

  17. Personality and attention: Levels of neuroticism and extraversion can predict attentional performance during a change detection task.

    PubMed

    Hahn, Sowon; Buttaccio, Daniel R; Hahn, Jungwon; Lee, Taehun

    2015-01-01

    The present study demonstrates that levels of extraversion and neuroticism can predict attentional performance during a change detection task. After completing a change detection task built on the flicker paradigm, participants were assessed for personality traits using the Revised Eysenck Personality Questionnaire (EPQ-R). Multiple regression analyses revealed that higher levels of extraversion predict increased change detection accuracies, while higher levels of neuroticism predict decreased change detection accuracies. In addition, neurotic individuals exhibited decreased sensitivity A' and increased fixation dwell times. Hierarchical regression analyses further revealed that eye movement measures mediate the relationship between neuroticism and change detection accuracies. Based on the current results, we propose that neuroticism is associated with decreased attentional control over the visual field, presumably due to decreased attentional disengagement. Extraversion can predict increased attentional performance, but the effect is smaller than the relationship between neuroticism and attention.

  18. Single Photon Counting Detectors for Low Light Level Imaging Applications

    NASA Astrophysics Data System (ADS)

    Kolb, Kimberly

    2015-10-01

    This dissertation presents the current state-of-the-art of semiconductor-based photon counting detector technologies. HgCdTe linear-mode avalanche photodiodes (LM-APDs), silicon Geiger-mode avalanche photodiodes (GM-APDs), and electron-multiplying CCDs (EMCCDs) are compared via their present and future performance in various astronomy applications. LM-APDs are studied in theory, based on work done at the University of Hawaii. EMCCDs are studied in theory and experimentally, with a device at NASA's Jet Propulsion Lab. The emphasis of the research is on GM-APD imaging arrays, developed at MIT Lincoln Laboratory and tested at the RIT Center for Detectors. The GM-APD research includes a theoretical analysis of SNR and various performance metrics, including dark count rate, afterpulsing, photon detection efficiency, and intrapixel sensitivity. The effects of radiation damage on the GM-APD were also characterized by introducing a cumulative dose of 50 krad(Si) via 60 MeV protons. Extensive development of Monte Carlo simulations and practical observation simulations was completed, including simulated astronomical imaging and adaptive optics wavefront sensing. Based on theoretical models and experimental testing, both the current state-of-the-art performance and projected future performance of each detector are compared for various applications. LM-APD performance is currently not competitive with other photon counting technologies, and are left out of the application-based comparisons. In the current state-of-the-art, EMCCDs in photon counting mode out-perform GM-APDs for long exposure scenarios, though GM-APDs are better for short exposure scenarios (fast readout) due to clock-induced-charge (CIC) in EMCCDs. In the long term, small improvements in GM-APD dark current will make them superior in both long and short exposure scenarios for extremely low flux. The efficiency of GM-APDs will likely always be less than EMCCDs, however, which is particularly disadvantageous for moderate to high flux rates where dark noise and CIC are insignificant noise sources. Research into decreasing the dark count rate of GM-APDs will lead to development of imaging arrays that are competitive for low light level imaging and spectroscopy applications in the near future.

  19. Detector and readout performance goals for quantum well and strained layer superlattice focal plane arrays imaging under tactical and strategic backgrounds

    NASA Astrophysics Data System (ADS)

    Bandara, Sumith V.

    2009-11-01

    Advancements in III-V semiconductor based, Quantum-well infrared photodetector (QWIP) and Type-II Strained-Layer Superlattice detector (T2SLS) technologies have yielded highly uniform, large-format long-wavelength infrared (LWIR) QWIP FPAs and high quantum efficiency (QE), small format, LWIR T2SLS FPAs. In this article, we have analyzed the QWIP and T2SLS detector level performance requirements and readout integrated circuit (ROIC) noise levels for several staring array long-wavelength infrared (LWIR) imaging applications at various background levels. As a result of lower absorption QE and less than unity photoconductive gain, QWIP FPAs are appropriate for high background tactical applications. However, if the application restricts the integration time, QWIP FPA performance may be limited by the read noise of the ROIC. Rapid progress in T2SLS detector material has already demonstrated LWIR detectors with sufficient performance for tactical applications and potential for strategic applications. However, significant research is needed to suppress surface leakage currents in order to reproduce performances at pixel levels of T2SLS FPAs.

  20. Optimizing Surveillance Performance of Alpha-Fetoprotein by Selection of Proper Target Population in Chronic Hepatitis B

    PubMed Central

    Chung, Jung Wha; Kim, Beom Hee; Lee, Chung Seop; Kim, Gi Hyun; Sohn, Hyung Rae; Min, Bo Young; Song, Joon Chang; Park, Hyun Kyung; Jang, Eun Sun; Yoon, Hyuk; Kim, Jaihwan; Shin, Cheol Min; Park, Young Soo; Hwang, Jin-Hyeok; Jeong, Sook-Hyang; Kim, Nayoung; Lee, Dong Ho; Lee, Jaebong; Ahn, Soyeon

    2016-01-01

    Although alpha-fetoprotein (AFP) is the most widely used biomarker in hepatocellular carcinoma (HCC) surveillance, disease activity may also increase AFP levels in chronic hepatitis B (CHB). Since nucleos(t)ide analog (NA) therapy may reduce not only HBV viral loads and transaminase levels but also the falsely elevated AFP levels in CHB, we tried to determine whether exposure to NA therapy influences AFP performance and whether selective application can optimize the performance of AFP testing in CHB during HCC surveillance. A retrospective cohort of 6,453 CHB patients who received HCC surveillance was constructed from the electronic clinical data warehouse. Covariates of AFP elevation were determined from 53,137 AFP measurements, and covariate-specific receiver operating characteristics regression analysis revealed that albumin levels and exposure to NA therapy were independent determinants of AFP performance. C statistics were largest in patients with albumin levels ≥ 3.7 g/dL who were followed without NA therapy during study period, whereas AFP performance was poorest when tested in patients with NA therapy during study and albumin levels were < 3.7 g/dL (difference in C statics = 0.35, p < 0.0001). Contrary to expectation, CHB patients with current or recent exposure to NA therapy showed poorer performance of AFP during HCC surveillance. Combination of concomitant albumin levels and status of NA therapy can identify subgroup of CHB patients who will show optimized AFP performance. PMID:27997559

  1. Intelligence Level Performance Standards Research for Autonomous Vehicles

    PubMed Central

    Bostelman, Roger B.; Hong, Tsai H.; Messina, Elena

    2017-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV’s). However, performance standards for AGV’s and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance. PMID:28649189

  2. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    PubMed

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  3. Design Considerations For Imaging Charge-Coupled Device (ICCD) Star Sensors

    NASA Astrophysics Data System (ADS)

    McAloon, K. J.

    1981-04-01

    A development program is currently underway to produce a precision star sensor using imaging charge coupled device (ICCD) technology. The effort is the critical component development phase for the Air Force Multi-Mission Attitude Determination and Autonomous Navigation System (MADAN). A number of unique considerations have evolved in designing an arcsecond accuracy sensor around an ICCD detector. Three tiers of performance criteria are involved: at the spacecraft attitude determination system level, at the star sensor level, and at the detector level. Optimum attitude determination system performance involves a tradeoff between Kalman filter iteration time and sensor ICCD integration time. The ICCD star sensor lends itself to the use of a new approach in the functional interface between the attitude determination system and the sensor. At the sensor level image data processing tradeoffs are important for optimum sensor performance. These tradeoffs involve the sensor optic configuration, the optical point spread function (PSF) size and shape, the PSF position locator, and the microprocessor locator algorithm. Performance modelling of the sensor mandates the use of computer simulation programs. Five key performance parameters at the ICCD detector level are defined. ICCD error characteristics have also been isolated to five key parameters.

  4. An advanced Ni-Cd battery cell design

    NASA Technical Reports Server (NTRS)

    Miller, L.

    1986-01-01

    The evolution of an advanced Ni-Cd space battery cell design continues to prove very promising. High oxygen/hydrogen gas recombination rates (currently up to a C/5 charge rate) and increased electrolyte activation level tolerance (currently up to 5.6 grams Ah of positive capacity) were demonstrated by test. A superior performance, extended life battery cell offering advantages should soon be available for mission applications

  5. Prediction of habitual physical activity level and weight status from fundamental movement skill level.

    PubMed

    Bryant, Elizabeth Sarah; James, Rob S; Birch, Samantha Louise; Duncan, Mike

    2014-01-01

    Fundamental movement skills (FMS) have been assessed in children in order to investigate the issues of the low proportion of children who meet physical activity (PA) guidelines and rising levels of obesity. The aim of this research was to identify whether previous or current FMS level is a better predictor of PA levels and weight status in children. In January 2012 (year 1), 281 children were recruited from one primary school in the West Midlands, UK. Children performed eight FMS three times, which were videoed and assessed using a subjective checklist. Sprint speed and jump height were measured objectively. Height and mass were measured to calculate the body mass index to determine the weight status. Skinfold calliper readings were used to calculate body fat percentage. One year later, in January 2013, all these tests were repeated on the same children, with the additional collection of PA data via the use of pedometers. Following multiple linear regression, it was identified that prior mastery in FMS was a better predictor of current PA, whereas current FMS was a better predictor of current weight status. Overall, FMS mastery is needed in childhood to be able to participate in PA and maintain a healthy weight status.

  6. Gaze Behavior of Gymnastics Judges: Where Do Experienced Judges and Gymnasts Look While Judging?

    PubMed

    Pizzera, Alexandra; Möller, Carsten; Plessner, Henning

    2018-03-01

    Gymnastics judges and former gymnasts have been shown to be quite accurate in detecting errors and accurately judging performance. The purpose of the current study was to examine if this superior judging performance is reflected in judges' gaze behavior. Thirty-five judges were asked to judge 21 gymnasts who performed a skill on the vault in a video-based test. Classifying 1 sample on 2 different criteria, judging performance and gaze behavior were compared between judges with a higher license level and judges with a lower license level and between judges who were able to perform the skill (specific motor experience [SME]) and those who were not. The results revealed better judging performance among judges with a higher license level compared with judges with a lower license level and more fixations on the gymnast during the whole skill and the landing phase, specifically on the head and arms of the gymnast. Specific motor experience did not result in any differences in judging performance; however, judges with SME showed similar gaze patterns to those of judges with a high license level, with 1 difference in their increased focus on the gymnasts' feet. Superior judging performance seems to be reflected in a specific gaze behavior. This gaze behavior appears to partly stem from judges' own sensorimotor experiences for this skill and reflects the gymnasts' perspective onto the skill.

  7. Determination of adenosine phosphates in rat gastrocnemius at various postmortem intervals using high performance liquid chromatography.

    PubMed

    Huang, Hong; Yan, Youyi; Zuo, Zhong; Yang, Lin; Li, Bin; Song, Yu; Liao, Linchuan

    2010-09-01

    Although the change in adenosine phosphate levels in muscles may contribute to the development of rigor mortis, the relationship between their levels and the onset and development of rigor mortis has not been well elucidated. In the current study, levels of the adenosine phosphates including adenosine triphosphate (ATP), adenosine diphosphate (ADP), and adenosine monophosphate (AMP) in gastrocnemius at various postmortem intervals of 180 rats from different death modes were detected by high performance liquid chromatography. The results showed that the levels of ATP and ADP significantly decreased along with the postmortem period of rats from different death mode whereas the AMP level remained the same. In addition, it was found that changes in the ATP levels in muscles after death correlated well with the development of rigor mortis. Therefore, the ATP level could serve as a reference parameter for the deduction of rigor mortis in forensic science.

  8. Revisiting global mean sea level budget closure : Preliminary results from an integrative study within ESA's Climate Change Initiative -Sea level Budget Closure-Climate Change Initiative

    NASA Astrophysics Data System (ADS)

    Palanisamy, H.; Cazenave, A. A.

    2017-12-01

    The global mean sea level budget is revisited over two time periods: the entire altimetry era, 1993-2015 and the Argo/GRACE era, 2003-2015 using the version '0' of sea level components estimated by the SLBC-CCI teams. The SLBC-CCI is an European Space Agency's project on sea level budget closure using CCI products. Over the entire altimetry era, the sea level budget was performed as the sum of steric and mass components that include contributions from total land water storage, glaciers, ice sheets (Greenland and Antarctica) and total water vapor content. Over the Argo/GRACE era, it was performed as the sum of steric and GRACE based ocean mass. Preliminary budget analysis performed over the altimetry era (1993-2015) results in a trend value of 2.83 mm/yr. On comparison with the observed altimetry-based global mean sea level trend over the same period (3.03 ± 0.5 mm/yr), we obtain a residual of 0.2 mm/yr. In spite of a residual of 0.2 mm/yr, the sea level budget result obtained over the altimetry era is very promising as this has been performed using the version '0' of the sea level components. Furthermore, uncertainties are not yet included in this study as uncertainty estimation for each sea level component is currently underway. Over the Argo/GRACE era (2003-2015), the trend estimated from the sum of steric and GRACE ocean mass amounts to 2.63 mm/yr while that observed by satellite altimetry is 3.37 mm/yr, thereby leaving a residual of 0.7 mm/yr. Here an ensemble GRACE ocean mass data (mean of various available GRACE ocean mass data) was used for the estimation. Using individual GRACE data results in a residual range of 0.5 mm/yr -1.1 mm/yr. Investigations are under way to determine the cause of the vast difference between the observed sea level and the sea level obtained from steric and GRACE ocean mass. One main suspect is the impact of GRACE data gaps on sea level budget analysis due to lack of GRACE data over several months since 2011. The current action plan of the project is to work on an accurate closure of the sea level budget using both the above performed methodologies. We also intend to provide a standardized uncertainty estimation and to correctly identify the causes leading to sea level budget non-closure if that is the case.

  9. Anticipated debt and financial stress in medical students.

    PubMed

    Morra, Dante J; Regehr, Glenn; Ginsburg, Shiphra

    2008-01-01

    While medical student debt is increasing, the effect of debt on student well-being and performance remains unclear. As a part of a larger study examining medical student views of their future profession, data were collected to examine the role that current and anticipated debt has in predicting stress among medical students. A survey was administered to medical students in all four years at the University of Toronto. Of the 804 potential respondents across the four years of training, 549 surveys had sufficient data for inclusion in this analysis, for a response rate of 68%. Through multiple regression analysis, we evaluated the correlation between current and anticipated debt and financial stress. Although perceived financial stress correlates with both current and anticipated debt levels, anticipated debt was able to account for an additional 11.5% of variance in reported stress when compared to current debt levels alone. This study demonstrates a relationship between perceived financial stress and debt levels, and suggests that anticipated debt levels might be a more robust metric to capture financial burden, as it standardizes for year of training and captures future financial liabilities (future tuition and other future expenses).

  10. Do Differential Response Rates to Patient Surveys Between Organizations Lead to Unfair Performance Comparisons?: Evidence From the English Cancer Patient Experience Survey.

    PubMed

    Saunders, Catherine L; Elliott, Marc N; Lyratzopoulos, Georgios; Abel, Gary A

    2016-01-01

    Patient surveys typically have variable response rates between organizations, leading to concerns that such differences may affect the validity of performance comparisons. To explore the size and likely sources of associations between hospital-level survey response rates and patient experience. Cross-sectional mail survey including 60 patient experience items sent to 101,771 cancer survivors recently treated by 158 English NHS hospitals. Age, sex, race/ethnicity, socioeconomic status, clinical diagnosis, hospital type, and region were available for respondents and nonrespondents. The overall response rate was 67% (range, 39% to 77% between hospitals). Hospitals with higher response rates had higher scores for all items (Spearman correlation range, 0.03-0.44), particularly questions regarding hospital-level administrative processes, for example, procedure cancellations or medical note availability.From multivariable analysis, associations between individual patient experience and hospital-level response rates were statistically significant (P<0.05) for 53/59 analyzed questions, decreasing to 37/59 after adjusting for case-mix, and 25/59 after further adjusting for hospital-level characteristics.Predicting responses of nonrespondents, and re-estimating hypothetical hospital scores assuming a 100% response rate, we found that currently low performing hospitals would have attained even lower scores. Overall nationwide attainment would have decreased slightly to that currently observed. Higher response rate hospitals have more positive experience scores, and this is only partly explained by patient case-mix. High response rates may be a marker of efficient hospital administration, and higher quality that should not, therefore, be adjusted away in public reporting. Although nonresponse may result in slightly overestimating overall national levels of performance, it does not appear to meaningfully bias comparisons of case-mix-adjusted hospital results.

  11. Integrated modeling environment for systems-level performance analysis of the Next-Generation Space Telescope

    NASA Astrophysics Data System (ADS)

    Mosier, Gary E.; Femiano, Michael; Ha, Kong; Bely, Pierre Y.; Burg, Richard; Redding, David C.; Kissil, Andrew; Rakoczy, John; Craig, Larry

    1998-08-01

    All current concepts for the NGST are innovative designs which present unique systems-level challenges. The goals are to outperform existing observatories at a fraction of the current price/performance ratio. Standard practices for developing systems error budgets, such as the 'root-sum-of- squares' error tree, are insufficient for designs of this complexity. Simulation and optimization are the tools needed for this project; in particular tools that integrate controls, optics, thermal and structural analysis, and design optimization. This paper describes such an environment which allows sub-system performance specifications to be analyzed parametrically, and includes optimizing metrics that capture the science requirements. The resulting systems-level design trades are greatly facilitated, and significant cost savings can be realized. This modeling environment, built around a tightly integrated combination of commercial off-the-shelf and in-house- developed codes, provides the foundation for linear and non- linear analysis on both the time and frequency-domains, statistical analysis, and design optimization. It features an interactive user interface and integrated graphics that allow highly-effective, real-time work to be done by multidisciplinary design teams. For the NGST, it has been applied to issues such as pointing control, dynamic isolation of spacecraft disturbances, wavefront sensing and control, on-orbit thermal stability of the optics, and development of systems-level error budgets. In this paper, results are presented from parametric trade studies that assess requirements for pointing control, structural dynamics, reaction wheel dynamic disturbances, and vibration isolation. These studies attempt to define requirements bounds such that the resulting design is optimized at the systems level, without attempting to optimize each subsystem individually. The performance metrics are defined in terms of image quality, specifically centroiding error and RMS wavefront error, which directly links to science requirements.

  12. Performance degradation of photovoltaic modules at different sites

    NASA Astrophysics Data System (ADS)

    Arab, A. Hadj; Mahammed, I. Hadj; Ould Amrouche, S.; Taghezouit, B.; Yassaa, N.

    2018-05-01

    In this work are presented results of electrical performance measurements of 120 crystalline silicon PV modules following long-term outdoor measurements. A set of 90 PV modules represent the first grid-connected photovoltaic (PV) system in Algeria, installed at the level of the “Centre de Développement des Energies Renouvelables” (CDER) site (Mediterranean coast), Bouzareah. The other 30 PV modules were undertaken in an arid area of the desert region of Ghardaïa site, about 600 km south of Algiers, with measurements collected from different applications. Following different characterization tests, we noticed that the all tested PV modules kept their power-generating rate except a slight reduction. Therefore, a mathematical model has been used to carry out PV module testing at different irradiance and temperature levels. Hence, different PV module parameters have been calculated from the recorded values of the open-circuit voltage, the short-circuit current, the voltage and current at maximum power point. The electrical measurements have indicated different degradations of current-voltage parameters. All the PV modules stated a decrease in the nominal power, which is variable from one module to another.

  13. Spacesuit Portable Life Support System Breadboard (PLSS 1.0) Development and Test Results

    NASA Technical Reports Server (NTRS)

    Vogel, Matt R.; Watts, Carly

    2011-01-01

    A multi-year effort has been carried out at NASA-JSC to develop an advanced Extravehicular Activity (EVA) PLSS design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. Previous efforts have focused on modeling and analyzing the advanced PLSS architecture, as well as developing key enabling technologies. Like the current International Space Station (ISS) Extravehicular Mobility Unit (EMU) PLSS, the advanced PLSS comprises of three subsystems required to sustain the crew during EVA including the Thermal, Ventilation, and Oxygen Subsystems. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test rig that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off the shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, ventilation loop fan, Rapid Cycle Amine (RCA) swingbed, and Spacesuit Water Membrane Evaporator (SWME). Testing accumulated 239 hours over 45 days, while executing 172 test points. Specific PLSS 1.0 test objectives assessed during this testing include: confirming key individual components perform in a system level test as they have performed during component level testing; identifying unexpected system-level interactions; operating PLSS 1.0 in nominal steady-state EVA modes to baseline subsystem performance with respect to metabolic rate, ventilation loop pressure and flow rate, and environmental conditions; simulating nominal transient EVA operational scenarios; simulating contingency EVA operational scenarios; and further evaluating individual technology development components. Successful testing of the PLSS 1.0 provided a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected; furthermore, many system responses trended in accordance with pre-test predictions.

  14. Current status of Japanese detectors

    NASA Astrophysics Data System (ADS)

    Tatsumi, Daisuke; Takahashi, Ryutaro; Arai, Koji; Nakagawa, Noriyasu; Agatsuma, Kazuhiro; Yamazaki, Toshitaka; Fukushima, Mitsuhiro; Fujimoto, Masa-Katsu; Takamori, Akiteru; Bertolini, Alessandro; Sannibale, Virginio; DeSalvo, Riccardo; Márka, Szabolcs; Ando, Masaki; Tsubono, Kimio; Akutsu, Tomomi; Yamamoto, Kazuhiro; Ishitsuka, Hideki; Uchiyama, Takashi; Miyoki, Shinji; Ohashi, Masatake; Kuroda, Kazuaki; Awaya, Norichika; Kanda, Nobuyuki; Araya, Akito; Telada, Souichi; Tomaru, Takayuki; Haruyama, Tomiyoshi; Yamamoto, Akira; Sato, Nobuaki; Suzuki, Toshitaka; Shintomi, Takakazu

    2007-10-01

    The current status of the TAMA and CLIO detectors in Japan is reported in this paper. These two interferometric gravitational wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year. TAMA300 is being upgraded to improve the sensitivity in a low-frequency region after the last observational experiment in 2004. To reduce the seismic noises, we are installing a new seismic isolation system, called the TAMA seismic attenuation system, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for the LCGT. The next data taking is planned for the summer of 2007. CLIO is a 100 m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates the Kamioka underground site for a low-seismic noise level, and adopts cryogenic Sapphire mirrors for low-thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observational experiments at room temperature have been done. Once the displacement noise reaches the thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.

  15. Solid polymer electrolyte (SPE) fuel cell technology program, phase 2/2A. [testing and evaluations

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Test evaluations were performed on a fabricated single solid polymer electrolyte cell unit. The cell operated at increased current density and at higher performance levels. This improved performance was obtained through a combination of increased temperature, increased reactant pressures, improved activation techniques and improved thermal control over the baseline cell configuration. The cell demonstrated a higher acid content membrane which resulted in increased performance. Reduced catalyst loading and low cost membrane development showed encouraging results.

  16. Role of Copper in the Performance of CdS/CdTe Solar Cells (Poster)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demtsu, S.; Albin, D.; Sites, J.

    2006-05-01

    The performance of CdS/CdTe solar cells made with evaporated Cu as a primary back contact was studied through current-voltage (JV) at different intensities, quantum efficiency (QE) under light and voltage bias, capacitance-voltage (CV), and drive-level capacitance profiling (DLCP) measurements. The results show that while modest amounts of Cu enhance cell performance, excessive amounts degrade device quality and reduce performance. The analysis is supported with numerical simulations to reproduce and explain some of the experimental results.

  17. Sources of sport confidence, imagery type and performance among competitive athletes: the mediating role of sports confidence.

    PubMed

    Levy, A R; Perry, J; Nicholls, A R; Larkin, D; Davies, J

    2015-01-01

    This study explored the mediating role of sport confidence upon (1) sources of sport confidence-performance relationship and (2) imagery-performance relationship. Participants were 157 competitive athletes who completed state measures of confidence level/sources, imagery type and performance within one hour after competition. Among the current sample, confirmatory factor analysis revealed appropriate support for the nine-factor SSCQ and the five-factor SIQ. Mediational analysis revealed that sport confidence had a mediating influence upon the achievement source of confidence-performance relationship. In addition, both cognitive and motivational imagery types were found to be important sources of confidence, as sport confidence mediated imagery type- performance relationship. Findings indicated that athletes who construed confidence from their own achievements and report multiple images on a more frequent basis are likely to benefit from enhanced levels of state sport confidence and subsequent performance.

  18. Unreviewed Disposal Question Evaluation: Impact of New Information since 2008 PA on Current Low-Level Solid Waste Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G.; Smith, F.; Hamm, L.

    2014-10-06

    Solid low-level waste disposal operations are controlled in part by an E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA) that was completed by the Savannah River National Laboratory (SRNL) in 2008 (WSRC 2008). Since this baseline analysis, new information pertinent to disposal operations has been identified as a natural outcome of ongoing PA maintenance activities and continuous improvement in model simulation techniques (Flach 2013). An Unreviewed Disposal Question (UDQ) Screening (Attachment 1) has been initiated regarding the continued ability of the ELLWF to meet Department of Energy (DOE) Order 435.1 performance objectives in light of new PA items and datamore » identified since completion of the original UDQ Evaluation (UDQE). The present UDQE assesses the ability of Solid Waste (SW) to meet performance objectives by estimating the influence of new information items on a recent sum-of-fractions (SOF) snapshot for each currently active E-Area low-level waste disposal unit. A final SOF, as impacted by this new information, is projected based on the assumptions that the current disposal limits, Waste Information Tracking System (WITS) administrative controls, and waste stream composition remain unchanged through disposal unit operational closure (Year 2025). Revision 1 of this UDQE addresses the following new PA items and data identified since completion of the original UDQE report in 2013: New K d values for iodine, radium and uranium; Elimination of cellulose degradation product (CDP) factors; Updated radionuclide data; Changes in transport behavior of mobile radionuclides; Potential delay in interim closure beyond 2025; and Component-in-grout (CIG) plume interaction correction. Consideration of new information relative to the 2008 PA baseline generally indicates greater confidence that PA performance objectives will be met than indicated by current SOF metrics. For SLIT9, the previous prohibition of non-crushable containers in revision 0 of this UDQE has rendered the projected final SOF for SLIT9 less than the WITS Admin Limit. With respect to future disposal unit operations in the East Slit Trench Group, consideration of new information for Slit Trench#14 (SLIT14) reduced the current SOF for the limiting All-Pathways 200-1000 year period (AP2) by an order of magnitude and by one quarter for the Beta-Gamma 12-100 year period (BG2) pathway. On the balance, updates to K{sub d} values and dose factors and elimination of CDP factors (generally favorable) more than compensated for the detrimental impact of a more rigorous treatment of plume dispersion. These observations suggest that future operations in the East Slit Trench Group can be conducted with higher confidence using current inventory limits, and that limits could be increased if desired for future low-level waste disposal units. The same general conclusion applies to future ST’s in the West Slit Trench Group based on the Impacted Final SOFs for existing ST’s in that area.« less

  19. Systems level test and simulation for photonic processing systems

    NASA Astrophysics Data System (ADS)

    Erteza, I. A.; Stalker, K. T.

    1995-08-01

    Photonic technology is growing in importance throughout DOD. Programs have been underway in each of the Services to demonstrate the ability of photonics to enhance current electronic performance in several prototype systems, such as the Navy's SLQ-32 radar warning receiver, the Army's multi-role survivable radar and the phased array radar controller for the Airborne Warning and Control System (AWACS) upgrade. Little, though, is known about radiation effects; the component studies do not furnish the information needed to predict overall system performance in a radiation environment. To date, no comprehensive test and analysis program has been conducted to evaluate sensitivity of overall system performance to the radiation environment. The goal of this program is to relate component level effects to system level performance through modeling and testing of a selected optical processing system, and to help direct component testing to items which can directly and adversely affect overall system performance. This report gives a broad overview of the project, highlighting key results.

  20. Five-year ITS program plan

    DOT National Transportation Integrated Search

    2000-09-01

    The current performance-related specifications (PRS) methodology has been under development by the Federal Highway Administration (FHWA) for several years and has now reached a level at which it can be implemented by State highway agencies. PRS for h...

  1. NASCOM network ground communications availability report

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A performance analysis of NASCOM Network circuits is presented. An objective of 99.80 percent availability has been established for all network circuits and an acceptable level of 99.50. A network narrative summary for the current month includes changes in network configurations, current month's totals for modes of service and trouble category losses, a discussion of trends, and significant losses that affected the performance indexes of individual or groups of circuits. A table and narrative summary of those circuits that failed to meet the objective of 99.80% availability for all network circuits and an acceptable level of 99.50. Lost time and interruption tables showing all circuits affected by outages, by trouble category, with their total time and events, scheduled operating hours, and individual availability indexes also are included. Selected circuits whose availabilities have or continue to affect the overall network availability are also analyzed.

  2. State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes-The Need for Novel Non-Invasive Techniques.

    PubMed

    Greene, Jacob; Louis, Julien; Korostynska, Olga; Mason, Alex

    2017-02-23

    Muscle glycogen levels have a profound impact on an athlete's sporting performance, thus measurement is vital. Carbohydrate manipulation is a fundamental component in an athlete's lifestyle and is a critical part of elite performance, since it can provide necessary training adaptations. This paper provides a critical review of the current invasive and non-invasive methods for measuring skeletal muscle glycogen levels. These include the gold standard muscle biopsy, histochemical analysis, magnetic resonance spectroscopy, and musculoskeletal high frequency ultrasound, as well as pursuing future application of electromagnetic sensors in the pursuit of portable non-invasive quantification of muscle glycogen. This paper will be of interest to researchers who wish to understand the current and most appropriate techniques in measuring skeletal muscle glycogen. This will have applications both in the lab and in the field by improving the accuracy of research protocols and following the physiological adaptations to exercise.

  3. User-Defined Data Distributions in High-Level Programming Languages

    NASA Technical Reports Server (NTRS)

    Diaconescu, Roxana E.; Zima, Hans P.

    2006-01-01

    One of the characteristic features of today s high performance computing systems is a physically distributed memory. Efficient management of locality is essential for meeting key performance requirements for these architectures. The standard technique for dealing with this issue has involved the extension of traditional sequential programming languages with explicit message passing, in the context of a processor-centric view of parallel computation. This has resulted in complex and error-prone assembly-style codes in which algorithms and communication are inextricably interwoven. This paper presents a high-level approach to the design and implementation of data distributions. Our work is motivated by the need to improve the current parallel programming methodology by introducing a paradigm supporting the development of efficient and reusable parallel code. This approach is currently being implemented in the context of a new programming language called Chapel, which is designed in the HPCS project Cascade.

  4. Measuring Information Security Performance with 10 by 10 Model for Holistic State Evaluation

    PubMed Central

    2016-01-01

    Organizations should measure their information security performance if they wish to take the right decisions and develop it in line with their security needs. Since the measurement of information security is generally underdeveloped in practice and many organizations find the existing recommendations too complex, the paper presents a solution in the form of a 10 by 10 information security performance measurement model. The model—ISP 10×10M is composed of ten critical success factors, 100 key performance indicators and 6 performance levels. Its content was devised on the basis of findings presented in the current research studies and standards, while its structure results from an empirical research conducted among information security professionals from Slovenia. Results of the study show that a high level of information security performance is mostly dependent on measures aimed at managing information risks, employees and information sources, while formal and environmental factors have a lesser impact. Experts believe that information security should evolve systematically, where it’s recommended that beginning steps include technical, logical and physical security controls, while advanced activities should relate predominantly strategic management activities. By applying the proposed model, organizations are able to determine the actual level of information security performance based on the weighted indexing technique. In this manner they identify the measures they ought to develop in order to improve the current situation. The ISP 10×10M is a useful tool for conducting internal system evaluations and decision-making. It may also be applied to a larger sample of organizations in order to determine the general state-of-play for research purposes. PMID:27655001

  5. Cost minimisation analysis of provision of oxygen at home: are the Drug Tariff guidelines cost effective?

    PubMed Central

    Heaney, Liam G; McAllister, Denise; MacMahon, Joseph

    1999-01-01

    Objectives To determine the level of oxygen cylinder use at which it becomes more cost effective to provide oxygen by concentrator at home in Northern Ireland, and to examine potential cost savings if cylinder use above this level had been replaced by concentrator in 1996. Design Cost minimisation analysis. Setting Area health boards in Northern Ireland. Main outcome measures Cost effective cut off point for switch to provision of oxygen from cylinder to concentrator. Potential maximum and minimum savings in Northern Ireland (sensitivity analysis) owing to switch to more cost effective strategy on the basis of provision of cylinders in 1996. Results In Northern Ireland it is currently cost effective to provide oxygen by concentrator when the patient is using three or more cylinders per month independent of the duration of the prescription. More widespread use of concentrators at this level of provision is likely to lead to a cost saving. Conclusions The Drug Tariff prescribing guidelines, advocating that provision of oxygen by concentrator becomes cheaper when 21 cylinders are being used per month—are currently inaccurate in Northern Ireland. Regional health authorities should review their current arrangements for provision of oxygen at home and perform a cost analysis to determine at what level it becomes more cost effective to provide oxygen by concentrator. Key messagesThe current Drug Tariff prescribing guidelines are not cost effective for provision of oxygen at home in Northern IrelandIndividual prescriptions detailing frequency of usage and delivery costs should be recordedA switch to a more cost effective strategy is likely to result in a cost savingRegional health authorities should examinecurrent arrangements for provision of oxygen at home and should perform cost analyses PMID:10390453

  6. The Relationship of Level of Positive Mental Health with Current Mental Disorders in Predicting Suicidal Behavior and Academic Impairment in College Students

    ERIC Educational Resources Information Center

    Keyes, Corey L. M.; Eisenberg, Daniel; Perry, Geraldine S.; Dube, Shanta R.; Kroenke, Kurt; Dhingra, Satvinder S.

    2012-01-01

    Objective: To investigate whether level of positive mental health complements mental illness in predicting students at risk for suicidal behavior and impaired academic performance. Participants: A sample of 5,689 college students participated in the 2007 Healthy Minds Study and completed an Internet survey that included the Mental Health…

  7. Miniature Biometric Sensor Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Terrier, Douglas; Clayton, Ronald; Hanson, Andrea; Cooper, Tommy; Downs, Meghan; Flint, Stephanie; Reyna, Baraquiel; Simon, Cory; Wilt, Grier

    2015-01-01

    Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.

  8. U.S. Coast Guard Officer Performance Management System: An Analysis of Current Commitment Levels and Potential Effectiveness Indicators.

    DTIC Science & Technology

    1983-03-01

    dons separately by Ivancevich (Ref. 23], and Latham [Ref. 24], indicate tha- these skills(performance measurement anr communication skills) are best...56, p. 295-247,254, 1977 ... . 22. Argyris,C. and Schon,D.A., Oranizaticnal Learning: a Wes ey, 7-11 1Pe 23. Ivancevich ,J.M., "A Longitudinal Study of

  9. High reliability level on single-mode 980nm-1060 nm diode lasers for telecommunication and industrial applications

    NASA Astrophysics Data System (ADS)

    Van de Casteele, J.; Bettiati, M.; Laruelle, F.; Cargemel, V.; Pagnod-Rossiaux, P.; Garabedian, P.; Raymond, L.; Laffitte, D.; Fromy, S.; Chambonnet, D.; Hirtz, J. P.

    2008-02-01

    We demonstrate very high reliability level on 980-1060nm high-power single-mode lasers through multi-cell tests. First, we show how our chip design and technology enables high reliability levels. Then, we aged 758 devices during 9500 hours among 6 cells with high current (0.8A-1.2A) and high submount temperature (65°C-105°C) for the reliability demonstration. Sudden catastrophic failure is the main degradation mechanism observed. A statistical failure rate model gives an Arrhenius thermal activation energy of 0.51eV and a power law forward current acceleration factor of 5.9. For high-power submarine applications (360mW pump module output optical power), this model exhibits a failure rate as low as 9 FIT at 13°C, while ultra-high power terrestrial modules (600mW) lie below 220 FIT at 25°C. Wear-out phenomena is observed only for very high current level without any reliability impact under 1.1A. For the 1060nm chip, step-stress tests were performed and a set of devices were aged during more than 2000 hours in different stress conditions. First results are in accordance with 980nm product with more than 100khours estimated MTTF. These reliability and performance features of 980-1060nm laser diodes will make high-power single-mode emitters the best choice for a number of telecommunication and industrial applications in the next few years.

  10. IAC level "O" program development

    NASA Technical Reports Server (NTRS)

    Vos, R. G.

    1982-01-01

    The current status of the IAC development activity is summarized. The listed prototype software and documentation was delivered, and details were planned for development of the level 1 operational system. The planned end product IAC is required to support LSST design analysis and performance evaluation, with emphasis on the coupling of required technical disciplines. The long term IAC effectively provides two distinct features: a specific set of analysis modules (thermal, structural, controls, antenna radiation performance and instrument optical performance) that will function together with the IAC supporting software in an integrated and user friendly manner; and a general framework whereby new analysis modules can readily be incorporated into IAC or be allowed to communicate with it.

  11. Critical determinants of combined sprint and endurance performance: an integrative analysis from muscle fiber to the human body.

    PubMed

    van der Zwaard, Stephan; van der Laarse, Willem J; Weide, Guido; Bloemers, Frank W; Hofmijster, Mathijs J; Levels, Koen; Noordhof, Dionne A; de Koning, Jos J; de Ruiter, Cornelis J; Jaspers, Richard T

    2018-04-01

    Optimizing physical performance is a major goal in current physiology. However, basic understanding of combining high sprint and endurance performance is currently lacking. This study identifies critical determinants of combined sprint and endurance performance using multiple regression analyses of physiologic determinants at different biologic levels. Cyclists, including 6 international sprint, 8 team pursuit, and 14 road cyclists, completed a Wingate test and 15-km time trial to obtain sprint and endurance performance results, respectively. Performance was normalized to lean body mass 2/3 to eliminate the influence of body size. Performance determinants were obtained from whole-body oxygen consumption, blood sampling, knee-extensor maximal force, muscle oxygenation, whole-muscle morphology, and muscle fiber histochemistry of musculus vastus lateralis. Normalized sprint performance was explained by percentage of fast-type fibers and muscle volume ( R 2 = 0.65; P < 0.001) and normalized endurance performance by performance oxygen consumption ( V̇o 2 ), mean corpuscular hemoglobin concentration, and muscle oxygenation ( R 2 = 0.92; P < 0.001). Combined sprint and endurance performance was explained by gross efficiency, performance V̇o 2 , and likely by muscle volume and fascicle length ( P = 0.056; P = 0.059). High performance V̇o 2 related to a high oxidative capacity, high capillarization × myoglobin, and small physiologic cross-sectional area ( R 2 = 0.67; P < 0.001). Results suggest that fascicle length and capillarization are important targets for training to optimize sprint and endurance performance simultaneously.-Van der Zwaard, S., van der Laarse, W. J., Weide, G., Bloemers, F. W., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Koning, J. J., de Ruiter, C. J., Jaspers, R. T. Critical determinants of combined sprint and endurance performance: an integrative analysis from muscle fiber to the human body.

  12. Multiresolution modeling with a JMASS-JWARS HLA Federation

    NASA Astrophysics Data System (ADS)

    Prince, John D.; Painter, Ron D.; Pendell, Brian; Richert, Walt; Wolcott, Christopher

    2002-07-01

    CACI, Inc.-Federal has built, tested, and demonstrated the use of a JMASS-JWARS HLA Federation that supports multi- resolution modeling of a weapon system and its subsystems in a JMASS engineering and engagement model environment, while providing a realistic JWARS theater campaign-level synthetic battle space and operational context to assess the weapon system's value added and deployment/employment supportability in a multi-day, combined force-on-force scenario. Traditionally, acquisition analyses require a hierarchical suite of simulation models to address engineering, engagement, mission and theater/campaign measures of performance, measures of effectiveness and measures of merit. Configuring and running this suite of simulations and transferring the appropriate data between each model is both time consuming and error prone. The ideal solution would be a single simulation with the requisite resolution and fidelity to perform all four levels of acquisition analysis. However, current computer hardware technologies cannot deliver the runtime performance necessary to support the resulting extremely large simulation. One viable alternative is to integrate the current hierarchical suite of simulation models using the DoD's High Level Architecture in order to support multi- resolution modeling. An HLA integration eliminates the extremely large model problem, provides a well-defined and manageable mixed resolution simulation and minimizes VV&A issues.

  13. An in flight investigation of pitch rate flight control systems and application of frequency domain and time domain predictive criteria

    NASA Technical Reports Server (NTRS)

    Berthe, C. J.; Chalk, C. R.; Sarrafian, S.

    1984-01-01

    The degree of attitude control provided by current integral-proportional pitch rate command-type control systems, while a prerequisite for flared landing, is insufficient for 'Level 1' performance. The pilot requires 'surrogate' feedback cues to precisely control flight path in the landing flare. Monotonic stick forces and pilot station vertical acceleration are important cues which can be provided by means of angle-of-attack and pitch rate feedback in order to achieve conventional short period and phugoid characteristics. Integral-proportional pitch rate flight control systems can be upgraded to Level 1 flared landing performance by means of lead/lag and washout prefilters in the command path. Strong pilot station vertical acceleration cues can provide Level 1 flared landing performance even in the absence of monotonic stick forces.

  14. Performance of Mashona doelings supplemented with different levels of velvet bean (Mucuna pruriens L. DC. var. utilis) seed meal.

    PubMed

    Madzimure, James; Mutema, Nyasha; Chimonyo, Michael; Bakare, Archibold Garikai; Mapiye, Cletos

    2014-06-01

    The objective of the current study was to evaluate the effects of feeding increasing levels of velvet bean seed meal (VBM; 0, 12, 24, and 36 %) on the performance of Mashona doelings. Dry matter intake was lower (P < 0.05) for the control diet compared to VBM diets, but linearly declined (P < 0.05) with increasing levels of VBM. Average daily weight gain was significantly different between experimental groups. Doelings' final live weights and average daily gains were slightly higher in control group than other three supplemented groups where they linearly declined (P < 0.05) with increasing levels of VBM. The cost per kilogram of feed, however, decreased with high inclusion level of VBM. Result suggested that high inclusion level of VBM negatively influenced the growth of young goats probably due to the presence of some anti-nutritional factors which needs further investigation.

  15. Spacer engineered Trigate SOI TFET: An investigation towards harsh temperature environment applications

    NASA Astrophysics Data System (ADS)

    Mallikarjunarao; Ranjan, Rajeev; Pradhan, K. P.; Artola, L.; Sahu, P. K.

    2016-09-01

    In this paper, a novel N-channel Tunnel Field Effect Transistor (TFET) i.e., Trigate Silicon-ON-Insulator (SOI) N-TFET with high-k spacer is proposed for better Sub-threshold swing (SS) and OFF-state current (IOFF) by keeping in mind the sensitivity towards temperature. The proposed model can achieve a Sub-threshold swing less than 35 mV/decade at various temperatures, which is desirable for designing low power CTFET for digital circuit applications. In N-TFET source doping has a significant effect on the ON-state current (ION) level; therefore more electrons will tunnel from source to channel region. High-k Spacer i.e., HfO2 is used to enhance the device performance and also it avoids overlapping of transistors in an integrated circuits (IC's). We have designed a reliable device by performing the temperature analysis on Transfer characteristics, Drain characteristics and also on various performance metrics like ON-state current (ION), OFF-state current (IOFF), ION/IOFF, Trans-conductance (gm), Trans-conductance Generation Factor (TGF), Sub-threshold Swing (SS) to observe the applications towards harsh temperature environment.

  16. Correlations between the changes in patients' dental-facial morphology at the end of the orthodontic treatment and the psychological variables.

    PubMed

    Vaida, Ligia; Pirte, Adriana; Corega, Claudia; Slăvescu, D; Muţiu, Gabriela

    2009-01-01

    The purpose of this research was to assess the impact that the improvement of patients' dental-facial morphology has at the end of the orthodontic treatment upon the following psychological variables: self-esteem, current self-related thoughts as well as upon the variables of social self-esteem and performance. The number of patients included in the study was of 168 (82 children and 86 adolescents) who carried out the orthodontic treatment. At the end of the active treatment, we applied to all patients the assessment instruments for the level of self- esteem and self-related current thoughts: the Rosenberg's Self-Esteem Scale and the Heatherton & Polivy Current Thoughts Scale. As far as the patients in the study are concerned, the improvement of their facial aspect at the end of the treatment showed a significantly positive correlation with the variables of global self-esteem, self-related current thoughts, social self-esteem and performance, with the exception of the girls in children study group who showed no correlations between physical aspect and the performance variable.

  17. Gallium Electromagnetic (GEM) Thruster Performance Measurements

    NASA Technical Reports Server (NTRS)

    Thomas, Robert E.; Burton, Rodney L.; Polzin, K. A.

    2009-01-01

    Discharge current, terminal voltage, and mass bit measurements are performed on a coaxial gallium electromagnetic thruster at discharge currents in the range of 7-23 kA. It is found that the mass bit varies quadratically with the discharge current which yields a constant exhaust velocity of 20 km/s. Increasing the electrode radius ratio of the thruster from to 2.6 to 3.4 increases the thruster efficiency from 21% to 30%. When operating with a central gallium anode, macroparticles are ejected at all energy levels tested. A central gallium cathode ejects macroparticles when the current density exceeds 3.7 10(exp 8) A/square m . A spatially and temporally broad spectroscopic survey in the 220-520 nm range is used to determine which species are present in the plasma. The spectra show that neutral, singly, and doubly ionized gallium species are present in the discharge, as well as annular electrode species at higher energy levels. Axial Langmuir triple probe measurements yield electron temperatures in the range of 0.8-3.8 eV and electron densities in the range of 8 x 10(exp )20 to 1.6 x 10(exp 21) m(exp -3) . Triple probe measurements suggest an exhaust plume with a divergence angle of 9 , and a completely doubly ionized plasma at the ablating thruster cathode.

  18. Performance Simulation of Unipolar InAs/InAs1-x Sb x Type-II Superlattice Photodetector

    NASA Astrophysics Data System (ADS)

    Singh, Anand; Pal, Ravinder

    2018-05-01

    This paper reports performance simulation of a unipolar tunable band gap InAs-InAsSb type-II superlattice (T2SL) infrared photodetector. The generation-recombination and surface leakage currents limit the performance of T2SL photodiodes. Unipolar nBn device design incorporating a suitable barrier layer in the diode structure is taken to suppress the Auger recombination and tunneling currents. At low reverse bias, the generation-recombination current is negligible in the absence of a depletion region, but the dark current is dominated by the diffusion current at higher operation temperatures. The composition, band alignment, barrier width, doping level and thickness of the absorber region are optimized here to achieve low dark current and high quantum efficiency at elevated operating temperatures. Thin unipolar T2SL absorbers are placed in a resonant cavity to enhance photon-material interaction, thus allowing complete absorption in a thinner detector element. It leads to the reduction in the detector volume for lower dark current without affecting the quantum efficiency. It shows an improvement in the quantum efficiency and reduction in the dark current. Dark current density ˜ 10-5 A/cm2 is achievable with low absorber thickness of 2 μm and effective lifetime of 250 ns in the InAs/InAs0.6Sb0.4/B-AlAs1-x Sb x long wave length T2SL detector at 110 K.

  19. Technology development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a candidate large UV-Optical-Infrared (LUVOIR) surveyor

    NASA Astrophysics Data System (ADS)

    Bolcar, Matthew R.; Balasubramanian, Kunjithapatham; Clampin, Mark; Crooke, Julie; Feinberg, Lee; Postman, Marc; Quijada, Manuel; Rauscher, Bernard; Redding, David; Rioux, Norman; Shaklan, Stuart; Stahl, H. Philip; Stahle, Carl; Thronson, Harley

    2015-09-01

    The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x10-10 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing and control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 μm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (~290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

  20. Technology Development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a Candidate Large UV-Optical-Infrared (LUVOIR) Surveyor

    NASA Technical Reports Server (NTRS)

    Bolcar, Matthew R.; Balasubramanian, Kunjithapatha; Clampin, Mark; Crooke, Julie; Feinberg, Lee; Postman, Marc; Quijada, Manuel; Rauscher, Bernard; Redding, David; Rioux, Norman; hide

    2015-01-01

    The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x10?10 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing & control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 µm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

  1. Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography.

    PubMed

    Lee, E J; Lee, S K; Agid, R; Howard, P; Bae, J M; terBrugge, K

    2009-10-01

    The combined automatic tube current modulation (ATCM) technique adapts and modulates the x-ray tube current in the x-y-z axis according to the patient's individual anatomy. We compared image quality and radiation dose of the combined ATCM technique with those of a fixed tube current (FTC) technique in craniocervical CT angiography performed with a 64-section multidetector row CT (MDCT) system. A retrospective review of craniocervical CT angiograms (CTAs) by using combined ATCM (n = 25) and FTC techniques (n = 25) was performed. Other CTA parameters, such as kilovolt (peak), matrix size, FOV, section thickness, pitch, contrast agent, and contrast injection techniques, were held constant. We recorded objective image noise in the muscles at 2 anatomic levels: radiation exposure doses (CT dose index volume and dose-length product); and subjective image quality parameters, such as vascular delineation of various arterial vessels, visibility of small arterial detail, image artifacts, and certainty of diagnosis. The Mann-Whitney U test was used for statistical analysis. No significant difference was detected in subjective image quality parameters between the FTC and combined ATCM techniques. Most subjects in both study groups (49/50, 98%) had acceptable subjective artifacts. The objective image noise values at shoulder level did not show a significant difference, but the noise value at the upper neck was higher with the combined ATCM (P < .05) technique. Significant reduction in radiation dose (18% reduction) was noted with the combined ATCM technique (P < .05). The combined ATCM technique for craniocervical CTA performed at 64-section MDCT substantially reduced radiation exposure dose but maintained diagnostic image quality.

  2. Performance improvement induced by asymmetric Y2O3-coated device structure to carbon-nanotube-film based photodetectors

    NASA Astrophysics Data System (ADS)

    Wang, Fanglin; Xu, Haitao; Huang, Huixin; Ma, Ze; Wang, Sheng; Peng, Lian-Mao

    2017-11-01

    Film-based semiconducting carbon nanotube (CNT) photodetectors are promising candidates for industrial applications. However, unintentional doping from the environment such as water/oxygen (H2O/O2) redox, polymers, etc. changes the doping level of the CNT film. Here, we evaluate the performance of film-based barrier-free bipolar diodes (BFBDs), which are basically semiconducting CNT films asymmetrically contacted by perfect n-type ohmic contact (scandium, Sc) and p-type ohmic contact (palladium, Pd) at the two ends of the diode. We show that normal BFBD devices have large variances of forward current, reverse current, and photocurrent for different doping levels of the channel. We propose an asymmetric Y2O3-coated BFBD device in which the channel is covered by a layer of an Y2O3 film and an overlap between the Sc electrode and the Y2O3 film is designed. The Y2O3 film provides p-type doping to the channel. The overlap section increases the length of the base of the pn junction, and the diffusion current of holes is suppressed. In this way, the rectifier factors (current ratio when voltages are at +0.5 V and -0.5 V) of the asymmetric Y2O3-coated BFBD devices are around two orders of magnitude larger and the photocurrent generation is more stable compared to that of normal devices. Our results provide a way to conquer the influence of unintentional doping from the environment and suppress reverse current in pn diodes. This is beneficial to applications of CNT-based photodetectors and of importance for inspiring methods to improve the performances of devices based on other low dimensional materials.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Enyuan; Wang, Xuelong; Yu, Xiqian

    The rechargeable lithium-ion battery (LIB) is the most promising energy storage system to power electric vehicles with high energy density and long cycling life. However, in order to meet customers’ demands for fast charging, the power performances of current LIBs need to be improved. From the cathode aspect, layer-structured cathode materials are widely used in today’s market and will continue to play important roles in the near future. The high rate capability of layered cathode materials during charging and discharging is critical to the power performance of the whole cell and the thermal stability is closely related to the safetymore » issues. Therefore, the in-depth understanding of structural changes of layered cathode materials during high rate charging/discharging and the thermal stability during heating are essential in developing new materials and improving current materials. Since structural changes take place from the atomic level to the whole electrode level, combination of characterization techniques covering multilength scales is quite important. Finally, in many cases, this means using comprehensive tools involving diffraction, spectroscopy, and imaging to differentiate the surface from the bulk and to obtain structural/chemical information with different levels of spatial resolution.« less

  4. Performance of ultra-thin whitetopping (UTW) in Oklahoma.

    DOT National Transportation Integrated Search

    2010-12-01

    With the current level of deterioration of pavements in Oklahoma and the United States a satisfactory repai : technique that is economical and can be applied rapidly while resisting a significant volume of traffic is becomin : important. Thin concret...

  5. The impact of culture and education on non-verbal neuropsychological measurements: a critical review.

    PubMed

    Rosselli, Mónica; Ardila, Alfredo

    2003-08-01

    Clinical neuropsychology has frequently considered visuospatial and non-verbal tests to be culturally and educationally fair or at least fairer than verbal tests. This paper reviews the cross-cultural differences in performance on visuoperceptual and visuoconstructional ability tasks and analyzes the impact of education and culture on non-verbal neuropsychological measurements. This paper compares: (1) non-verbal test performance among groups with different educational levels, and the same cultural background (inter-education intra-culture comparison); (2) the test performance among groups with the same educational level and different cultural backgrounds (intra-education inter-culture comparisons). Several studies have demonstrated a strong association between educational level and performance on common non-verbal neuropsychological tests. When neuropsychological test performance in different cultural groups is compared, significant differences are evident. Performance on non-verbal tests such as copying figures, drawing maps or listening to tones can be significantly influenced by the individual's culture. Arguments against the use of some current neuropsychological non-verbal instruments, procedures, and norms in the assessment of diverse educational and cultural groups are discussed and possible solutions to this problem are presented.

  6. Two-IMU FDI performance of the sequential probability ratio test during shuttle entry

    NASA Technical Reports Server (NTRS)

    Rich, T. M.

    1976-01-01

    Performance data for the sequential probability ratio test (SPRT) during shuttle entry are presented. Current modeling constants and failure thresholds are included for the full mission 3B from entry through landing trajectory. Minimum 100 percent detection/isolation failure levels and a discussion of the effects of failure direction are presented. Finally, a limited comparison of failures introduced at trajectory initiation shows that the SPRT algorithm performs slightly worse than the data tracking test.

  7. First principles calculations of La2O3/GaAs interface properties under biaxial strain and hydrostatic pressure

    NASA Astrophysics Data System (ADS)

    Shi, Li-Bin; Li, Ming-Biao; Xiu, Xiao-Ming; Liu, Xu-Yang; Zhang, Kai-Cheng; Li, Chun-Ran; Dong, Hai-Kuan

    2017-04-01

    La2O3 is a potential dielectric material with high permittivity (high-κ) for metal-oxide-semiconductor (MOS) devices. However, band offsets and oxide defects should still be concerned. Smaller band offsets and carrier traps increase leakage current, and degenerate performance of the devices. In this paper, the interface behaviors of La2O3/GaAs under biaxial strain and hydrostatic pressure are investigated, which is performed by first principles calculations based on density functional theory (DFT). Strain engineering is attempted to improve performance of the metal/La2O3/GaAs devices. First of all, we creatively realize band alignment of La2O3/GaAs interface under biaxial strain and hydrostatic pressure. The proper biaxial tensile strain can effectively increase valence band offsets (VBO) and conduction band offsets (CBO), which can be used to suppress leakage current. However, the VBO will decrease with the increase of hydrostatic pressure, indicating that performance of the devices is degenerated. Then, a direct tunneling leakage current model is used to investigate current and voltage characteristics of the metal/La2O3/GaAs. The impact of biaxial strain and hydrostatic pressure on leakage current is discussed. At last, formation energies and transition levels of oxygen interstitial (Oi) and oxygen vacancy (VO) in La2O3 are assessed. We investigate how they will affect performance of the devices.

  8. Ramp compression of a metallic liner driven by a shaped 5 MA current on the SPHINX machine

    NASA Astrophysics Data System (ADS)

    D'Almeida, Thierry; Lassalle, Francis; Morell, Alain; Grunenwald, Julien; Zucchini, Frédéric; Loyen, Arnaud; Maysonnave, Thomas; Chuvatin, Alexandre

    2013-06-01

    SPHINX is a 6MA, 1- μs Linear Transformer Driver operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. Among the options that are currently being considered for improving the generator performances, there is a compact Dynamic Load Current Amplifier (DLCM). A method for performing magnetic ramp compression experiments, without modifying the generator operation scheme, was developed using the DLCM to shape the initial current pulse. We present the overall experimental configuration chosen for these experiments, based on electrical and hydrodynamic simulations. Initial results obtained over a set of experiments on an aluminum cylindrical liner, ramp-compressed to a peak pressure of 23 GPa, are presented. Details of the electrical and Photonic Doppler Velocimetry (PDV) setups used to monitor and diagnose the ramp compression experiments are provided. Current profiles measured at various locations across the system, particularly the load current, agree with simulated current profile and demonstrate adequate pulse shaping by the DLCM. The liner inner free surface velocity measurements agree with the hydrocode results obtained using the measured load current as the input. Higher ramp pressure levels are foreseen in future experiments with an improved DLCM system.

  9. From SED HI concept to Pleiades FM detection unit measurements

    NASA Astrophysics Data System (ADS)

    Renard, Christophe; Dantes, Didier; Neveu, Claude; Lamard, Jean-Luc; Oudinot, Matthieu; Materne, Alex

    2017-11-01

    The first flight model PLEIADES high resolution instrument under Thales Alenia Space development, on behalf of CNES, is currently in integration and test phases. Based on the SED HI detection unit concept, PLEIADES detection unit has been fully qualified before the integration at telescope level. The main radiometric performances have been measured on engineering and first flight models. This paper presents the results of performances obtained on the both models. After a recall of the SED HI concept, the design and performances of the main elements (charge coupled detectors, focal plane and video processing unit), detection unit radiometric performances are presented and compared to the instrument specifications for the panchromatic and multispectral bands. The performances treated are the following: - video signal characteristics, - dark signal level and dark signal non uniformity, - photo-response non uniformity, - non linearity and differential non linearity, - temporal and spatial noises regarding system definitions PLEIADES detection unit allows tuning of different functions: reference and sampling time positioning, anti-blooming level, gain value, TDI line number. These parameters are presented with their associated criteria of optimisation to achieve system radiometric performances and their sensitivities on radiometric performances. All the results of the measurements performed by Thales Alenia Space on the PLEIADES detection units demonstrate the high potential of the SED HI concept for Earth high resolution observation system allowing optimised performances at instrument and satellite levels.

  10. Design and Development of Lateral Flight Director

    NASA Technical Reports Server (NTRS)

    Kudlinski, Kim E.; Ragsdale, William A.

    1999-01-01

    The current control law used for the flight director in the Boeing 737 simulator is inadequate with large localizer deviations near the middle marker. Eight different control laws are investigated. A heuristic method is used to design control laws that meet specific performance criteria. The design of each is described in detail. Several tests were performed and compared with the current control law for the flight director. The goal was to design a control law for the flight director that can be used with large localizer deviations near the middle marker, which could be caused by winds or wake turbulence, without increasing its level of complexity.

  11. A new low voltage level-shifted FVF current mirror with enhanced bandwidth and output resistance

    NASA Astrophysics Data System (ADS)

    Aggarwal, Bhawna; Gupta, Maneesha; Gupta, Anil Kumar; Sangal, Ankur

    2016-10-01

    This paper proposes a new high-performance level-shifted flipped voltage follower (LSFVF) based low-voltage current mirror (CM). The proposed CM utilises the low-supply voltage and low-input resistance characteristics of a flipped voltage follower (FVF) CM. In the proposed CM, level-shifting configuration is used to obtain a wide operating current range and resistive compensation technique is employed to increase the operating bandwidth. The peaking in frequency response is reduced by using an additional large MOSFET. Moreover, a very high output resistance (in GΩ range) along with low-current transfer error is achieved through super-cascode configuration for a wide current range (0-440 µA). Small signal analysis is carried out to show the improvements achieved at each step. The proposed CM is simulated by Mentor Graphics Eldospice in TSMC 0.18 µm CMOS, BSIM3 and Level 53 technology. In the proposed CM, a bandwidth of 6.1799 GHz, 1% settling time of 0.719 ns, input and output resistances of 21.43 Ω and 1.14 GΩ, respectively, are obtained with a single supply voltage of 1 V. The layout of the proposed CM has been designed and post-layout simulation results have been shown. The post-layout simulation results for Monte Carlo and temperature analysis have also been included to show the reliability of the CM against the variations in process parameters and temperature changes.

  12. Noise in CdZnTe detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luke, P. N.; Amman, M.; Lee J. S.

    2000-10-10

    Noise in CdZnTe devices with different electrode configurations was investigated. Measurements on devices with guard-ring electrode structures showed that surface leakage current does not produce any significant noise. The parallel white noise component of the devices appeared to be generated by the bulk current alone, even though the surface current was substantially higher. This implies that reducing the surface leakage current of a CdZnTe detector may not necessarily result in a significant improvement in noise performance. The noise generated by the bulk current is also observed to be below full shot noise. This partial suppression of shot noise may bemore » the result of Coulomb interaction between carriers or carrier trapping. Devices with coplanar strip electrodes were observed to produce a 1/f noise term at the preamplifier output. Higher levels of this 1/f noise were observed with decreasing gap widths between electrodes. The level of this 1/f noise appeared to be independent of bias voltage and leakage current but was substantially reduced after certain surface treatments.« less

  13. Jet noise suppressor nozzle development for augmentor wing jet STOL research aircraft (C-8A Buffalo)

    NASA Technical Reports Server (NTRS)

    Harkonen, D. L.; Marks, C. C.; Okeefe, J. V.

    1974-01-01

    Noise and performance test results are presented for a full-scale advanced design rectangular array lobe jet suppressor nozzle (plain wall and corrugated). Flight design and installation considerations are also discussed. Noise data are presented in terms of peak PNLT (perceived noise level, tone corrected) suppression relative to the existing airplane and one-third octave-band spectra. Nozzle performance is presented in terms of velocity coefficient. Estimates of the hot thrust available during emergency (engine out) with the suppressor nozzle installed are compared with the current thrust levels produced by the round convergent nozzles.

  14. Ultrastable low-noise current amplifier: a novel device for measuring small electric currents with high accuracy.

    PubMed

    Drung, D; Krause, C; Becker, U; Scherer, H; Ahlers, F J

    2015-02-01

    An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

  15. Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drung, D.; Krause, C.; Becker, U.

    2015-02-15

    An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibratemore » both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.« less

  16. Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

    NASA Astrophysics Data System (ADS)

    Drung, D.; Krause, C.; Becker, U.; Scherer, H.; Ahlers, F. J.

    2015-02-01

    An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

  17. The Use of Individual Growth and Developmental Indicators for Progress Monitoring and Intervention Decision Making in Early Education

    ERIC Educational Resources Information Center

    Walker, Dale; Carta, Judith J.; Greenwood, Charles R.; Buzhardt, Joseph F.

    2008-01-01

    Progress monitoring tools have been shown to be essential elements in current approaches to intervention problem-solving models. Such tools have been valuable not only in marking individual children's level of performance relative to peers but also in measuring change in skill level in a way that can be attributed to intervention and development.…

  18. Cellular Sentinels Toxicity Platform

    DTIC Science & Technology

    2017-02-01

    Air Force Research Laboratory 711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Aeromedical Research Department 2510 Fifth St...toxicity testing is to assess the likely risks posed to human populations at ambient exposure levels. Unfortunately, current approaches to toxicology... human populations at ambient exposure levels. For the past 50 years, this goal has been met by high dose testing in experimental animals with

  19. Implementation of Enhanced Propulsion Control Modes for Emergency Flight Operation

    NASA Technical Reports Server (NTRS)

    Csank, Jeffrey T.; Chin, Jeffrey C.; May, Ryan D.; Litt, Jonathan S.; Guo, Ten-Huei

    2011-01-01

    Aircraft engines can be effective actuators to help pilots avert or recover from emergency situations. Emergency control modes are being developed to enhance the engines performance to increase the probability of recovery under these circumstances. This paper discusses a proposed implementation of an architecture that requests emergency propulsion control modes, allowing the engines to deliver additional performance in emergency situations while still ensuring a specified safety level. In order to determine the appropriate level of engine performance enhancement, information regarding the current emergency scenario (including severity) and current engine health must be known. This enables the engine to operate beyond its nominal range while minimizing overall risk to the aircraft. In this architecture, the flight controller is responsible for determining the severity of the event and the level of engine risk that is acceptable, while the engine controller is responsible for delivering the desired performance within the specified risk range. A control mode selector specifies an appropriate situation-specific enhanced mode, which the engine controller then implements. The enhanced control modes described in this paper provide additional engine thrust or response capabilities through the modification of gains, limits, and the control algorithm, but increase the risk of engine failure. The modifications made to the engine controller to enable the use of the enhanced control modes are described, as are the interaction between the various subsystems and importantly, the interaction between the flight controller/pilot and the propulsion control system. Simulation results demonstrate how the system responds to requests for enhanced operation and the corresponding increase in performance.

  20. Roofline model toolkit: A practical tool for architectural and program analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo, Yu Jung; Williams, Samuel; Van Straalen, Brian

    We present preliminary results of the Roofline Toolkit for multicore, many core, and accelerated architectures. This paper focuses on the processor architecture characterization engine, a collection of portable instrumented micro benchmarks implemented with Message Passing Interface (MPI), and OpenMP used to express thread-level parallelism. These benchmarks are specialized to quantify the behavior of different architectural features. Compared to previous work on performance characterization, these microbenchmarks focus on capturing the performance of each level of the memory hierarchy, along with thread-level parallelism, instruction-level parallelism and explicit SIMD parallelism, measured in the context of the compilers and run-time environments. We also measuremore » sustained PCIe throughput with four GPU memory managed mechanisms. By combining results from the architecture characterization with the Roofline model based solely on architectural specifications, this work offers insights for performance prediction of current and future architectures and their software systems. To that end, we instrument three applications and plot their resultant performance on the corresponding Roofline model when run on a Blue Gene/Q architecture.« less

  1. [Acceptance and commitment therapy (ACT) and improving chess performance in promising young chess-players].

    PubMed

    Ruiz, Francisco J; Luciano, Carmen

    2009-08-01

    Acceptance and Commitment Therapy (ACT) is shown to be effective in relatively distant fields from the so-called psychological disorders. One of these areas is sport performance improvement. The aim of the current study is to expand the application of brief ACT protocols to improve chess-players' performance. In a previous study, a brief protocol was applied to international-level adult chess-players that was effective. The current study aims to apply an equivalent brief ACT protocol, but in this case, applied in a group format to promising young chess-players. In addition, this brief protocol is compared to a non-intervention control condition. Results show that the ACT brief protocol improved the performance in 5 out of 7 participants, and that none of the chess-players in the control condition reached the established change criterion. The differences between the conditions in chess performance were statistically significant. The results are discussed, emphasizing the replicated impact of a brief ACT protocol on the improvement of chess-players' performance.

  2. The method of educational assessment affects children's neural processing and performance: behavioural and fMRI Evidence

    NASA Astrophysics Data System (ADS)

    Howard, Steven J.; Burianová, Hana; Calleia, Alysha; Fynes-Clinton, Samuel; Kervin, Lisa; Bokosmaty, Sahar

    2017-08-01

    Standardised educational assessments are now widespread, yet their development has given comparatively more consideration to what to assess than how to optimally assess students' competencies. Existing evidence from behavioural studies with children and neuroscience studies with adults suggest that the method of assessment may affect neural processing and performance, but current evidence remains limited. To investigate the impact of assessment methods on neural processing and performance in young children, we used functional magnetic resonance imaging to identify and quantify the neural correlates during performance across a range of current approaches to standardised spelling assessment. Results indicated that children's test performance declined as the cognitive load of assessment method increased. Activation of neural nodes associated with working memory further suggests that this performance decline may be a consequence of a higher cognitive load, rather than the complexity of the content. These findings provide insights into principles of assessment (re)design, to ensure assessment results are an accurate reflection of students' true levels of competency.

  3. State Education Trends: Academic Performance and Spending over the Past 40 Years. Policy Analysis No. 746

    ERIC Educational Resources Information Center

    Coulson, Andrew J.

    2014-01-01

    Long-term trends in academic performance and spending are valuable tools for evaluating past education policies and informing current ones. But such data have been scarce at the state level, where the most important education policy decisions are made. State spending data exist reaching back to the 1960s, but the figures have been scattered across…

  4. The impact of rare earth cobalt permanent magnets on electromechanical device design

    NASA Technical Reports Server (NTRS)

    Fisher, R. L.; Studer, P. A.

    1979-01-01

    Specific motor designs which employ rare earth cobalt magnets are discussed with special emphasis on their unique properties and magnetic field geometry. In addition to performance improvements and power savings, high reliability devices are attainable. Both the mechanism and systems engineering should be aware of the new performance levels which are currently becoming available as a result of the rare earth cobalt magnets.

  5. Performance of Portable Ventilators at Altitude

    DTIC Science & Technology

    2015-03-30

    collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT...Deploying ventilators that can maintain a consistent tidal volume (VT) delivery at various altitudes is imperative for lung protection when...performance of mechanical ventilators calibrated for operation at sea level. Deploying ventilators that can maintain a consistent tidal volume (VT) delivery

  6. Antecedent Factors Affecting Academic Performance of Graduate Students at the Nairobi Evangelical Graduate School of Theology

    ERIC Educational Resources Information Center

    Mbogo, Rosemary Wahu

    2016-01-01

    This paper reports the findings of a Master's level thesis work that was done in 1997 to assess the antecedent factors affecting the academic performance of graduate students at the Nairobi Evangelical School of Theology (N.E.G.S.T.), which is currently Africa International University (AIU). The paper reviews the effect of lack of finance on…

  7. Extracorporeal Stimulation of Sacral Nerve Roots for Observation of Pelvic Autonomic Nerve Integrity: Description of a Novel Methodological Setup.

    PubMed

    Moszkowski, Tomasz; Kauff, Daniel W; Wegner, Celine; Ruff, Roman; Somerlik-Fuchs, Karin H; Kruger, Thilo B; Augustyniak, Piotr; Hoffmann, Klaus-Peter; Kneist, Werner

    2018-03-01

    Neurophysiologic monitoring can improve autonomic nerve sparing during critical phases of rectal cancer surgery. To develop a system for extracorporeal stimulation of sacral nerve roots. Dedicated software controlled a ten-electrode stimulation array by switching between different electrode configurations and current levels. A built-in impedance and current level measurement assessed the effectiveness of current injection. Intra-anal surface electromyography (sEMG) informed on targeting the sacral nerve roots. All tests were performed on five pig specimens. During switching between electrode configurations, the system delivered 100% of the set current (25 mA, 30 Hz, 200 μs cathodic pulses) in 93% of 250 stimulation trains across all specimens. The impedance measured between single stimulation array contacts and corresponding anodes across all electrode configurations and specimens equaled 3.7 ± 2.5 kΩ. The intra-anal sEMG recorded a signal amplitude increase as previously observed in the literature. When the stimulation amplitude was tested in the range from 1 to 21 mA using the interconnected contacts of the stimulation array and the intra-anal anode, the impedance remained below 250 Ω and the system delivered 100% of the set current in all cases. Intra-anal sEMG showed an amplitude increase for current levels exceeding 6 mA. The system delivered stable electric current, which was proved by built-in impedance and current level measurements. Intra-anal sEMG confirmed the ability to target the branches of the autonomous nervous system originating from the sacral nerve roots. Stimulation outside of the operative field during rectal cancer surgery is feasible and may improve the practicality of pelvic intraoperative neuromonitoring.

  8. NOVA: A new multi-level logic simulator

    NASA Technical Reports Server (NTRS)

    Miles, L.; Prins, P.; Cameron, K.; Shovic, J.

    1990-01-01

    A new logic simulator that was developed at the NASA Space Engineering Research Center for VLSI Design was described. The simulator is multi-level, being able to simulate from the switch level through the functional model level. NOVA is currently in the Beta test phase and was used to simulate chips designed for the NASA Space Station and the Explorer missions. A new algorithm was devised to simulate bi-directional pass transistors and a preliminary version of the algorithm is presented. The usage of functional models in NOVA is also described and performance figures are presented.

  9. Noise-robust speech triage.

    PubMed

    Bartos, Anthony L; Cipr, Tomas; Nelson, Douglas J; Schwarz, Petr; Banowetz, John; Jerabek, Ladislav

    2018-04-01

    A method is presented in which conventional speech algorithms are applied, with no modifications, to improve their performance in extremely noisy environments. It has been demonstrated that, for eigen-channel algorithms, pre-training multiple speaker identification (SID) models at a lattice of signal-to-noise-ratio (SNR) levels and then performing SID using the appropriate SNR dependent model was successful in mitigating noise at all SNR levels. In those tests, it was found that SID performance was optimized when the SNR of the testing and training data were close or identical. In this current effort multiple i-vector algorithms were used, greatly improving both processing throughput and equal error rate classification accuracy. Using identical approaches in the same noisy environment, performance of SID, language identification, gender identification, and diarization were significantly improved. A critical factor in this improvement is speech activity detection (SAD) that performs reliably in extremely noisy environments, where the speech itself is barely audible. To optimize SAD operation at all SNR levels, two algorithms were employed. The first maximized detection probability at low levels (-10 dB ≤ SNR < +10 dB) using just the voiced speech envelope, and the second exploited features extracted from the original speech to improve overall accuracy at higher quality levels (SNR ≥ +10 dB).

  10. Analyzing Reliability and Performance Trade-Offs of HLS-Based Designs in SRAM-Based FPGAs Under Soft Errors

    NASA Astrophysics Data System (ADS)

    Tambara, Lucas Antunes; Tonfat, Jorge; Santos, André; Kastensmidt, Fernanda Lima; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Silveira, Marcilei A. G.

    2017-02-01

    The increasing system complexity of FPGA-based hardware designs and shortening of time-to-market have motivated the adoption of new designing methodologies focused on addressing the current need for high-performance circuits. High-Level Synthesis (HLS) tools can generate Register Transfer Level (RTL) designs from high-level software programming languages. These tools have evolved significantly in recent years, providing optimized RTL designs, which can serve the needs of safety-critical applications that require both high performance and high reliability levels. However, a reliability evaluation of HLS-based designs under soft errors has not yet been presented. In this work, the trade-offs of different HLS-based designs in terms of reliability, resource utilization, and performance are investigated by analyzing their behavior under soft errors and comparing them to a standard processor-based implementation in an SRAM-based FPGA. Results obtained from fault injection campaigns and radiation experiments show that it is possible to increase the performance of a processor-based system up to 5,000 times by changing its architecture with a small impact in the cross section (increasing up to 8 times), and still increasing the Mean Workload Between Failures (MWBF) of the system.

  11. Pilot expertise and hippocampal size: associations with longitudinal flight simulator performance.

    PubMed

    Adamson, Maheen M; Bayley, Peter J; Scanlon, Blake K; Farrell, Michelle E; Hernandez, Beatriz; Weiner, Michael W; Yesavage, Jerome A; Taylor, Joy L

    2012-09-01

    Previous research suggests that the size of the hippocampus can vary in response to intensive training (e.g., during the acquisition of expert knowledge). However, the role of the hippocampus in maintenance of skilled performance is not well understood. The Stanford/Veterans Affairs Aviation MRI Study offers a unique opportunity to observe the interaction of brain structure and multiple levels of expertise on longitudinal flight simulator performance. The current study examined the relationship between hippocampal volume and three levels of aviation expertise, defined by pilot proficiency ratings issued by the U.S. Federal Aviation Administration (11). At 3 annual time points, 60 pilots who varied in their level of aviation expertise (ages ranging from 45 to 69 yr) were tested. At baseline, higher expertise was associated with better flight simulator performance, but not with hippocampal volume. Longitudinally, there was an Expertise x Hippocampal volume interaction, in the direction that a larger hippocampus was associated with better performance at higher levels of expertise. These results are consistent with the notion that expertise in a cognitively demanding domain involves the interplay of acquired knowledge ('mental schemas') and basic hippocampal-dependent processes.

  12. Associations of Affective Responses During Free-Living Physical Activity and Future Physical Activity Levels: an Ecological Momentary Assessment Study.

    PubMed

    Liao, Yue; Chou, Chih-Ping; Huh, Jimi; Leventhal, Adam; Dunton, Genevieve

    2017-08-01

    Affective response during physical activity may influence motivation to perform future physical activity behavior. However, affective response during physical activity is often assessed under controlled laboratory conditions. The current study used ecological momentary assessment (EMA) to capture affective responses during free-living physical activity performed by adults, and determined whether these affective responses predict future moderate-to-vigorous physical activity (MVPA) levels after 6 and 12 months. At baseline, electronic EMA surveys were randomly prompted across 4 days asking about current activities and affective states (e.g., happy, stressed, energetic, tired). Affective response during physical activity was operationalized as the level of positive or negative affect reported when concurrent physical activity (e.g., exercise or sports) was also reported. Data were available for 82 adults. Future levels of moderate-to-vigorous physical activity (MVPA) were measured using accelerometers, worn for seven consecutive days at 6 and 12 months after the baseline assessment. Feeling more energetic during physical activity was associated with performing more minutes of daily MVPA after both 6 and 12 months. Feeling less negative affect during physical activity was associated with engaging in more daily MVPA minutes after 12 months only. This study demonstrated how EMA can be used to capture affective responses during free-living physical activity. Results found that feelings more energetic and less negative during physical activity were associated with more future physical activity, suggesting that positive emotional benefits may reinforce behavior.

  13. Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

    NASA Technical Reports Server (NTRS)

    Armstrong, Michael J.; Blackwelder, Mark; Bollman, Andrew; Ross, Christine; Campbell, Angela; Jones, Catherine; Norman, Patrick

    2015-01-01

    The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

  14. Evaluation of the Terminal Sequencing and Spacing System for Performance Based Navigation Arrivals

    NASA Technical Reports Server (NTRS)

    Thipphavong, Jane; Jung, Jaewoo; Swenson, Harry N.; Martin, Lynne; Lin, Melody; Nguyen, Jimmy

    2013-01-01

    NASA has developed the Terminal Sequencing and Spacing (TSS) system, a suite of advanced arrival management technologies combining timebased scheduling and controller precision spacing tools. TSS is a ground-based controller automation tool that facilitates sequencing and merging arrivals that have both current standard ATC routes and terminal Performance-Based Navigation (PBN) routes, especially during highly congested demand periods. In collaboration with the FAA and MITRE's Center for Advanced Aviation System Development (CAASD), TSS system performance was evaluated in human-in-the-loop (HITL) simulations with currently active controllers as participants. Traffic scenarios had mixed Area Navigation (RNAV) and Required Navigation Performance (RNP) equipage, where the more advanced RNP-equipped aircraft had preferential treatment with a shorter approach option. Simulation results indicate the TSS system achieved benefits by enabling PBN, while maintaining high throughput rates-10% above baseline demand levels. Flight path predictability improved, where path deviation was reduced by 2 NM on average and variance in the downwind leg length was 75% less. Arrivals flew more fuel-efficient descents for longer, spending an average of 39 seconds less in step-down level altitude segments. Self-reported controller workload was reduced, with statistically significant differences at the p less than 0.01 level. The RNP-equipped arrivals were also able to more frequently capitalize on the benefits of being "Best-Equipped, Best- Served" (BEBS), where less vectoring was needed and nearly all RNP approaches were conducted without interruption.

  15. Age differences in feedback reactions: The roles of employee feedback orientation on social awareness and utility.

    PubMed

    Wang, Mo; Burlacu, Gabriela; Truxillo, Donald; James, Keith; Yao, Xiang

    2015-07-01

    Organizations worldwide are currently experiencing shifts in the age composition of their workforces. The workforce is aging and becoming increasingly age-diverse, suggesting that organizational researchers and practitioners need to better understand how age differences may manifest in the workplace and the implications for human resource practice. Integrating socioemotional selectivity theory with the performance feedback literature and using a time-lagged design, the current study examined age differences in moderating the relationships between the characteristics of performance feedback and employee reactions to the feedback event. The results suggest that older workers had higher levels of feedback orientation on social awareness, but lower levels of feedback orientation on utility than younger workers. Furthermore, the positive associations between favorability of feedback and feedback delivery and feedback reactions were stronger for older workers than for younger workers, whereas the positive association between feedback quality and feedback reactions was stronger for younger workers than for older workers. Finally, the current study revealed that age-related differences in employee feedback orientation could explain the different patterns of relationships between feedback characteristics and feedback reactions across older and younger workers. These findings have both theoretical and practical implications for building theory about workplace aging and improving ways that performance feedback is managed across employees from diverse age groups. (c) 2015 APA, all rights reserved).

  16. Simulated Prosthetic Vision: The Benefits of Computer-Based Object Recognition and Localization.

    PubMed

    Macé, Marc J-M; Guivarch, Valérian; Denis, Grégoire; Jouffrais, Christophe

    2015-07-01

    Clinical trials with blind patients implanted with a visual neuroprosthesis showed that even the simplest tasks were difficult to perform with the limited vision restored with current implants. Simulated prosthetic vision (SPV) is a powerful tool to investigate the putative functions of the upcoming generations of visual neuroprostheses. Recent studies based on SPV showed that several generations of implants will be required before usable vision is restored. However, none of these studies relied on advanced image processing. High-level image processing could significantly reduce the amount of information required to perform visual tasks and help restore visuomotor behaviors, even with current low-resolution implants. In this study, we simulated a prosthetic vision device based on object localization in the scene. We evaluated the usability of this device for object recognition, localization, and reaching. We showed that a very low number of electrodes (e.g., nine) are sufficient to restore visually guided reaching movements with fair timing (10 s) and high accuracy. In addition, performance, both in terms of accuracy and speed, was comparable with 9 and 100 electrodes. Extraction of high level information (object recognition and localization) from video images could drastically enhance the usability of current visual neuroprosthesis. We suggest that this method-that is, localization of targets of interest in the scene-may restore various visuomotor behaviors. This method could prove functional on current low-resolution implants. The main limitation resides in the reliability of the vision algorithms, which are improving rapidly. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. In-Flight Manual Electronics Repair for Deep-Space Missions

    NASA Technical Reports Server (NTRS)

    Pettegrew, Richard; Easton, John; Struk, Peter; Anderson, Eric

    2007-01-01

    Severe limitations on mass and volume available for spares on long-duration spaceflight missions will require electronics repair to be conducted at the component level, rather than at the sub-assembly level (referred to as Orbital Replacement Unit, or 'ORU'), as is currently the case aboard the International Space Station. Performing reliable component-level repairs in a reduced gravity environment by crew members will require careful planning, and some specialty tools and systems. Additionally, spacecraft systems must be designed to enable such repairs. This paper is an overview of a NASA project which examines all of these aspects of component level electronic repair. Results of case studies that detail how NASA, the U.S. Navy, and a commercial company currently approach electronics repair are presented, along with results of a trade study examining commercial technologies and solutions which may be used in future applications. Initial design recommendations resulting from these studies are also presented.

  18. Device and circuit-level performance of carbon nanotube field-effect transistor with benchmarking against a nano-MOSFET

    PubMed Central

    2012-01-01

    The performance of a semiconducting carbon nanotube (CNT) is assessed and tabulated for parameters against those of a metal-oxide-semiconductor field-effect transistor (MOSFET). Both CNT and MOSFET models considered agree well with the trends in the available experimental data. The results obtained show that nanotubes can significantly reduce the drain-induced barrier lowering effect and subthreshold swing in silicon channel replacement while sustaining smaller channel area at higher current density. Performance metrics of both devices such as current drive strength, current on-off ratio (Ion/Ioff), energy-delay product, and power-delay product for logic gates, namely NAND and NOR, are presented. Design rules used for carbon nanotube field-effect transistors (CNTFETs) are compatible with the 45-nm MOSFET technology. The parasitics associated with interconnects are also incorporated in the model. Interconnects can affect the propagation delay in a CNTFET. Smaller length interconnects result in higher cutoff frequency. PMID:22901374

  19. Efficacy of Directional Cues from a Tactile System for Target Orientation in Helicopter Extractions over Moving Targets

    DTIC Science & Technology

    2013-01-01

    incapacitating simulator sickness, current use of medications that alter sleep/ wake cycles, current acute illness, and significant sleep deprivation...tactile cueing using pager motors were not successful in the aviation environment due to ambient noise and vibration obscuring the tactile stimulus (see...continuous wakefulness ). Each day, each participant performed four, 10-minute stabilized hovering A B 6 maneuvers (at 70 feet above ground level

  20. Current research on aviation weather (bibliography), 1979

    NASA Technical Reports Server (NTRS)

    Turkel, B. S.; Frost, W.

    1980-01-01

    The titles, managers, supporting organizations, performing organizations, investigators and objectives of 127 current research projects in advanced meteorological instruments, forecasting, icing, lightning, visibility, low level wind shear, storm hazards/severe storms, and turbulence are tabulated and cross-referenced. A list of pertinent reference material produced through the above tabulated research activities is given. The acquired information is assembled in bibliography form to provide a readily available source of information in the area of aviation meteorology.

  1. Foundations for a syntatic pattern recognition system for genomic DNA sequences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Searles, D.B.

    1993-03-01

    The goal of the proposed work is the creation of a software system that will perform sophisticated pattern recognition and related functions at a level of abstraction and with expressive power beyond current general-purpose pattern-matching systems for biological sequences; and with a more uniform language, environment, and graphical user interface, and with greater flexibility, extensibility, embeddability, and ability to incorporate other algorithms, than current special-purpose analytic software.

  2. Validation of bending tests by nanoindentation for micro-contact analysis of MEMS switches

    NASA Astrophysics Data System (ADS)

    Broue, Adrien; Fourcade, Thibaut; Dhennin, Jérémie; Courtade, Frédéric; Charvet, Pierre–Louis; Pons, Patrick; Lafontan, Xavier; Plana, Robert

    2010-08-01

    Research on contact characterization for microelectromechanical system (MEMS) switches has been driven by the necessity to reach a high-reliability level for micro-switch applications. One of the main failures observed during cycling of the devices is the increase of the electrical contact resistance. The key issue is the electromechanical behaviour of the materials used at the contact interface where the current flows through. Metal contact switches have a large and complex set of failure mechanisms according to the current level. This paper demonstrates the validity of a new methodology using a commercial nanoindenter coupled with electrical measurements on test vehicles specially designed to investigate the micro-scale contact physics. Dedicated validation tests and modelling are performed to assess the introduced methodology by analyzing the gold contact interface with 5 µm2 square bumps at various current levels. Contact temperature rise is measured, which affects the mechanical properties of the contact materials and modifies the contact topology. In addition, the data provide a better understanding of micro-contact behaviour related to the impact of current at low- to medium-power levels. This article was originally submitted for the special section 'Selected papers from the 20th Micromechanics Europe Workshop (MME 09) (Toulouse, France, 20-22 September 2009)', Journal of Micromechanics and Microengineering, volume 20, issue 6.

  3. Using risk adjustment approaches in child welfare performance measurement: Applications and insights from health and mental health settings

    PubMed Central

    Raghavan, Ramesh

    2014-01-01

    Federal policymaking in the last decade has dramatically expanded performance measurement within child welfare systems, and states are currently being fiscally penalized for poor performance on defined outcomes. However, in contrast to performance measurement in health settings, current policy holds child welfare systems solely responsible for meeting outcomes, largely without taking into account the effects of factors at the level of the child, and his or her social ecology, that might undermine the performance of child welfare agencies. Appropriate measurement of performance is predicated upon the ability to disentangle individual, as opposed to organizational, determinants of outcomes, which is the goal of risk adjustment methodologies. This review briefly conceptualizes and examines risk adjustment approaches in health and child welfare, suggests approaches to expanding its use to appropriately measure the performance of child welfare agencies, and highlights research gaps that diminish the appropriate use of risk adjustment approaches – and which consequently suggest the need for caution – in policymaking around performance measurement of child welfare agencies. PMID:25253917

  4. Rectenna array measurement results

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  5. A methodology for image quality evaluation of advanced CT systems.

    PubMed

    Wilson, Joshua M; Christianson, Olav I; Richard, Samuel; Samei, Ehsan

    2013-03-01

    This work involved the development of a phantom-based method to quantify the performance of tube current modulation and iterative reconstruction in modern computed tomography (CT) systems. The quantification included resolution, HU accuracy, noise, and noise texture accounting for the impact of contrast, prescribed dose, reconstruction algorithm, and body size. A 42-cm-long, 22.5-kg polyethylene phantom was designed to model four body sizes. Each size was represented by a uniform section, for the measurement of the noise-power spectrum (NPS), and a feature section containing various rods, for the measurement of HU and the task-based modulation transfer function (TTF). The phantom was scanned on a clinical CT system (GE, 750HD) using a range of tube current modulation settings (NI levels) and reconstruction methods (FBP and ASIR30). An image quality analysis program was developed to process the phantom data to calculate the targeted image quality metrics as a function of contrast, prescribed dose, and body size. The phantom fabrication closely followed the design specifications. In terms of tube current modulation, the tube current and resulting image noise varied as a function of phantom size as expected based on the manufacturer specification: From the 16- to 37-cm section, the HU contrast for each rod was inversely related to phantom size, and noise was relatively constant (<5% change). With iterative reconstruction, the TTF exhibited a contrast dependency with better performance for higher contrast objects. At low noise levels, TTFs of iterative reconstruction were better than those of FBP, but at higher noise, that superiority was not maintained at all contrast levels. Relative to FBP, the NPS of iterative reconstruction exhibited an ~30% decrease in magnitude and a 0.1 mm(-1) shift in the peak frequency. Phantom and image quality analysis software were created for assessing CT image quality over a range of contrasts, doses, and body sizes. The testing platform enabled robust NPS, TTF, HU, and pixel noise measurements as a function of body size capable of characterizing the performance of reconstruction algorithms and tube current modulation techniques.

  6. Gender differences in mathematics anxiety and the relation to mathematics performance while controlling for test anxiety

    PubMed Central

    2012-01-01

    Background Mathematics anxiety (MA), a state of discomfort associated with performing mathematical tasks, is thought to affect a notable proportion of the school age population. Some research has indicated that MA negatively affects mathematics performance and that girls may report higher levels of MA than boys. On the other hand some research has indicated that boys’ mathematics performance is more negatively affected by MA than girls’ performance is. The aim of the current study was to measure girls’ and boys’ mathematics performance as well as their levels of MA while controlling for test anxiety (TA) a construct related to MA but which is typically not controlled for in MA studies. Methods Four-hundred and thirty three British secondary school children in school years 7, 8 and 10 completed customised mental mathematics tests and MA and TA questionnaires. Results No gender differences emerged for mathematics performance but levels of MA and TA were higher for girls than for boys. Girls and boys showed a positive correlation between MA and TA and a negative correlation between MA and mathematics performance. TA was also negatively correlated with mathematics performance, but this relationship was stronger for girls than for boys. When controlling for TA, the negative correlation between MA and performance remained for girls only. Regression analyses revealed that MA was a significant predictor of performance for girls but not for boys. Conclusions Our study has revealed that secondary school children experience MA. Importantly, we controlled for TA which is typically not controlled for in MA studies. Girls showed higher levels of MA than boys and high levels of MA were related to poorer levels of mathematics performance. As well as potentially having a detrimental effect on ‘online’ mathematics performance, past research has shown that high levels of MA can have negative consequences for later mathematics education. Therefore MA warrants attention in the mathematics classroom, particularly because there is evidence that MA develops during the primary school years. Furthermore, our study showed no gender difference in mathematics performance, despite girls reporting higher levels of MA. These results might suggest that girls may have had the potential to perform better than boys in mathematics however their performance may have been attenuated by their higher levels of MA. Longitudinal research is needed to investigate the development of MA and its effect on mathematics performance. PMID:22769743

  7. Gender differences in mathematics anxiety and the relation to mathematics performance while controlling for test anxiety.

    PubMed

    Devine, Amy; Fawcett, Kayleigh; Szűcs, Dénes; Dowker, Ann

    2012-07-09

    Mathematics anxiety (MA), a state of discomfort associated with performing mathematical tasks, is thought to affect a notable proportion of the school age population. Some research has indicated that MA negatively affects mathematics performance and that girls may report higher levels of MA than boys. On the other hand some research has indicated that boys' mathematics performance is more negatively affected by MA than girls' performance is. The aim of the current study was to measure girls' and boys' mathematics performance as well as their levels of MA while controlling for test anxiety (TA) a construct related to MA but which is typically not controlled for in MA studies. Four-hundred and thirty three British secondary school children in school years 7, 8 and 10 completed customised mental mathematics tests and MA and TA questionnaires. No gender differences emerged for mathematics performance but levels of MA and TA were higher for girls than for boys. Girls and boys showed a positive correlation between MA and TA and a negative correlation between MA and mathematics performance. TA was also negatively correlated with mathematics performance, but this relationship was stronger for girls than for boys. When controlling for TA, the negative correlation between MA and performance remained for girls only. Regression analyses revealed that MA was a significant predictor of performance for girls but not for boys. Our study has revealed that secondary school children experience MA. Importantly, we controlled for TA which is typically not controlled for in MA studies. Girls showed higher levels of MA than boys and high levels of MA were related to poorer levels of mathematics performance. As well as potentially having a detrimental effect on 'online' mathematics performance, past research has shown that high levels of MA can have negative consequences for later mathematics education. Therefore MA warrants attention in the mathematics classroom, particularly because there is evidence that MA develops during the primary school years. Furthermore, our study showed no gender difference in mathematics performance, despite girls reporting higher levels of MA. These results might suggest that girls may have had the potential to perform better than boys in mathematics however their performance may have been attenuated by their higher levels of MA. Longitudinal research is needed to investigate the development of MA and its effect on mathematics performance.

  8. A new balancing three level three dimensional space vector modulation strategy for three level neutral point clamped four leg inverter based shunt active power filter controlling by nonlinear back stepping controllers.

    PubMed

    Chebabhi, Ali; Fellah, Mohammed Karim; Kessal, Abdelhalim; Benkhoris, Mohamed F

    2016-07-01

    In this paper is proposed a new balancing three-level three dimensional space vector modulation (B3L-3DSVM) strategy which uses a redundant voltage vectors to realize precise control and high-performance for a three phase three-level four-leg neutral point clamped (NPC) inverter based Shunt Active Power Filter (SAPF) for eliminate the source currents harmonics, reduce the magnitude of neutral wire current (eliminate the zero-sequence current produced by single-phase nonlinear loads), and to compensate the reactive power in the three-phase four-wire electrical networks. This strategy is proposed in order to gate switching pulses generation, dc bus voltage capacitors balancing (conserve equal voltage of the two dc bus capacitors), and to switching frequency reduced and fixed of inverter switches in same times. A Nonlinear Back Stepping Controllers (NBSC) are used for regulated the dc bus voltage capacitors and the SAPF injected currents to robustness, stabilizing the system and to improve the response and to eliminate the overshoot and undershoot of traditional PI (Proportional-Integral). Conventional three-level three dimensional space vector modulation (C3L-3DSVM) and B3L-3DSVM are calculated and compared in terms of error between the two dc bus voltage capacitors, SAPF output voltages and THDv, THDi of source currents, magnitude of source neutral wire current, and the reactive power compensation under unbalanced single phase nonlinear loads. The success, robustness, and the effectiveness of the proposed control strategies are demonstrated through simulation using Sim Power Systems and S-Function of MATLAB/SIMULINK. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products

    NASA Astrophysics Data System (ADS)

    Williams, Don; Burns, Peter D.

    2007-01-01

    There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.

  10. Can Consumers Make Affordable Care Affordable? The Value of Choice Architecture

    PubMed Central

    Johnson, Eric J.; Hassin, Ran; Baker, Tom; Bajger, Allison T.; Treuer, Galen

    2013-01-01

    Tens of millions of people are currently choosing health coverage on a state or federal health insurance exchange as part of the Patient Protection and Affordable Care Act. We examine how well people make these choices, how well they think they do, and what can be done to improve these choices. We conducted 6 experiments asking people to choose the most cost-effective policy using websites modeled on current exchanges. Our results suggest there is significant room for improvement. Without interventions, respondents perform at near chance levels and show a significant bias, overweighting out-of-pocket expenses and deductibles. Financial incentives do not improve performance, and decision-makers do not realize that they are performing poorly. However, performance can be improved quite markedly by providing calculation aids, and by choosing a “smart” default. Implementing these psychologically based principles could save purchasers of policies and taxpayers approximately 10 billion dollars every year. PMID:24367484

  11. Performance Evaluation of III-V Hetero/Homojunction Esaki Tunnel Diodes on Si and Lattice Matched Substrates

    NASA Astrophysics Data System (ADS)

    Thomas, Paul M.

    Understanding of quantum tunneling phenomenon in semiconductor systems is increasingly important as CMOS replacement technologies are investigated. This work studies a variety of heterojunction materials and types to increase tunnel currents to CMOS competitive levels and to understand how integration onto Si substrates affects performance. Esaki tunnel diodes were grown by Molecular Beam Epitaxy (MBE) on Si substrates via a graded buffer and control Esaki tunnel diodes grown on lattice matched substrates for this work. Peak current density for each diode is extracted and benchmarked to build an empirical data set for predicting diode performance. Additionally, statistics are used as tool to show peak to valley ratio for the III-V on Si sample and the control perform similarly below a threshold area. This work has applications beyond logic, as multijunction solar cell, heterojunction bipolar transistor, and light emitting diode designs all benefit from better tunnel contact design.

  12. Improved LED backlight with unique color and intensity control and NVIS capability

    NASA Astrophysics Data System (ADS)

    Herman, Robert; Zagar, Pete; Ulijasz, Ted; Hansen, Hans C.; Ellner, Fred

    2006-05-01

    Currently deployed conventional flat panel AMLCD displays employ fluorescent lamp backlights to achieve the required lighting levels for cockpits in high performance aircraft. Advances have been made in backlighting technology by replacing fluorescent lamps with high performance LEDs. However, these new LED-based backlights are lacking in control of color and luminance intensity especially when related to NVIS requirements in a cockpit. This paper describes a unique integration of LED, electronic, and optical components to meet the requirements of high performance aircraft over their extreme range of operating environments. The LED-based backlight utilizes state-of-art components to enable daylight, night, and NVIS requirements to be implemented in a simple cost-effective package. The performance results presented highlight the advantages of this new design when compared to currently available backlighting designs. Techniques as described in section 2 of this paper are covered under patent application to the US and International Patent Offices.

  13. Preoperative surgical rehearsal using cadaveric fresh tissue surgical simulation increases resident operative confidence.

    PubMed

    Weber, Erin L; Leland, Hyuma A; Azadgoli, Beina; Minneti, Michael; Carey, Joseph N

    2017-08-01

    Rehearsal is an essential part of mastering any technical skill. The efficacy of surgical rehearsal is currently limited by low fidelity simulation models. Fresh cadaver models, however, offer maximal surgical simulation. We hypothesize that preoperative surgical rehearsal using fresh tissue surgical simulation will improve resident confidence and serve as an important adjunct to current training methods. Preoperative rehearsal of surgical procedures was performed by plastic surgery residents using fresh cadavers in a simulated operative environment. Rehearsal was designed to mimic the clinical operation, complete with a surgical technician to assist. A retrospective, web-based survey was used to assess resident perception of pre- and post-procedure confidence, preparation, technique, speed, safety, and anatomical knowledge on a 5-point scale (1= not confident, 5= very confident). Twenty-six rehearsals were performed by 9 residents (PGY 1-7) an average of 4.7±2.1 days prior to performance of the scheduled operation. Surveys demonstrated a median pre-simulation confidence score of 2 and a post-rehearsal score of 4 (P<0.01). The perceived improvement in confidence and performance was greatest when simulation was performed within 3 days of the scheduled case. All residents felt that cadaveric simulation was better than standard preparation methods of self-directed reading or discussion with other surgeons. All residents believed that their technique, speed, safety, and anatomical knowledge improved as a result of simulation. Fresh tissue-based preoperative surgical rehearsal was effectively implemented in the residency program. Resident confidence and perception of technique improved. Survey results suggest that cadaveric simulation is beneficial for all levels of residents. We believe that implementation of preoperative surgical rehearsal is an effective adjunct to surgical training at all skill levels in the current environment of decreased work hours.

  14. Analytical screening of low emissions, high performance duct burners for supersonic cruise aircraft engines

    NASA Technical Reports Server (NTRS)

    Lohmann, R. A.; Riecke, G. T.

    1977-01-01

    An analytical screening study was conducted to identify duct burner concepts capable of providing low emissions and high performance in advanced supersonic engines. Duct burner configurations ranging from current augmenter technology to advanced concepts such as premix-prevaporized burners were defined. Aerothermal and mechanical design studies provided the basis for screening these configurations using the criteria of emissions, performance, engine compatibility, cost, weight and relative risk. Technology levels derived from recently defined experimental low emissions main burners are required to achieve both low emissions and high performance goals. A configuration based on the Vorbix (Vortex burning and mixing) combustor concept was analytically determined to meet the performance goals and is consistent with the fan duct envelope of a variable cycle engine. The duct burner configuration has a moderate risk level compatible with the schedule of anticipated experimental programs.

  15. A Preliminary Foil Gas Bearing Performance Map

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Radil, Kevin C.; Bruckner, Robert J.; Howard, S. Adam

    2006-01-01

    Recent breakthrough improvements in foil gas bearing load capacity, high temperature tribological coatings and computer based modeling have enabled the development of increasingly larger and more advanced Oil-Free Turbomachinery systems. Successful integration of foil gas bearings into turbomachinery requires a step wise approach that includes conceptual design and feasibility studies, bearing testing, and rotor testing prior to full scale system level demonstrations. Unfortunately, the current level of understanding of foil gas bearings and especially their tribological behavior is often insufficient to avoid developmental problems thereby hampering commercialization of new applications. In this paper, a new approach loosely based upon accepted hydrodynamic theory, is developed which results in a "Foil Gas Bearing Performance Map" to guide the integration process. This performance map, which resembles a Stribeck curve for bearing friction, is useful in describing bearing operating regimes, performance safety margins, the effects of load on performance and limiting factors for foil gas bearings.

  16. Multicore Challenges and Benefits for High Performance Scientific Computing

    DOE PAGES

    Nielsen, Ida M. B.; Janssen, Curtis L.

    2008-01-01

    Until recently, performance gains in processors were achieved largely by improvements in clock speeds and instruction level parallelism. Thus, applications could obtain performance increases with relatively minor changes by upgrading to the latest generation of computing hardware. Currently, however, processor performance improvements are realized by using multicore technology and hardware support for multiple threads within each core, and taking full advantage of this technology to improve the performance of applications requires exposure of extreme levels of software parallelism. We will here discuss the architecture of parallel computers constructed from many multicore chips as well as techniques for managing the complexitymore » of programming such computers, including the hybrid message-passing/multi-threading programming model. We will illustrate these ideas with a hybrid distributed memory matrix multiply and a quantum chemistry algorithm for energy computation using Møller–Plesset perturbation theory.« less

  17. Caution and Warning Alarm Design and Evaluation for NASA CEV Auditory Displays: SHFE Information Presentation Directed Research Project (DRPP) report 12.07

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Godfroy, Martine; Sandor, Aniko; Holden, Kritina

    2008-01-01

    The design of caution-warning signals for NASA s Crew Exploration Vehicle (CEV) and other future spacecraft will be based on both best practices based on current research and evaluation of current alarms. A design approach is presented based upon cross-disciplinary examination of psychoacoustic research, human factors experience, aerospace practices, and acoustical engineering requirements. A listening test with thirteen participants was performed involving ranking and grading of current and newly developed caution-warning stimuli under three conditions: (1) alarm levels adjusted for compliance with ISO 7731, "Danger signals for work places - Auditory Danger Signals", (2) alarm levels adjusted to an overall 15 dBA s/n ratio and (3) simulated codec low-pass filtering. Questionnaire data yielded useful insights regarding cognitive associations with the sounds.

  18. Kickboxing review: anthropometric, psychophysiological and activity profiles and injury epidemiology

    PubMed Central

    Chaabene, H; Miarka, B; Franchini, E; Chamari, K; Cheour, F

    2017-01-01

    Kickboxing is one of the modern combat sports. The psychophysiological demands of a kickboxing competition require athletes to achieve high thresholds of several aspects of physical fitness. The aim of the current review is to critically analyse and appraise the kickboxer’s anthropometric, physiological, physical and psychological attributes with the activity profile and injury epidemiology in order to provide practical recommendations for training as well as new areas of scientific research. The available information shows that both amateur and elite-level male kickboxers are characterized by a higher proportion of mesomorphy with a well-developed muscle mass and low body fat percentage. While there is some variation in the maximum oxygen uptake of kickboxers, moderate to high cardio-respiratory levels are reported for these athletes. Regardless of kickboxers’ level, a high peak and mean anaerobic power output were reported. High-level kickboxing performance also requires well-developed muscle power in both the upper and lower limbs. Psychological factors contribute to success that requires high levels of self-confidence, motivation, dispositional hope and optimism, mental toughness/resiliency, and adaptive perfectionism. Psychological attributes also distinguished successful from less successful kickboxers. The activity-to-rest ratio was higher in elite (1:1) than both amateur and national-level (from 1:2 to 1:5) kickboxers, with no significant differences between rounds (round 1=1:4, and rounds 2 and 3=1:5) as well as between winners and losers in amateur and national-level simulated combats. These particular psychophysiological characteristics and performance aspects of kickboxers influence performance and could serve as guidance for training. Finally, kickboxing is characterized by chronic repetitive head trauma, which causes hypopituitarism due to traumatic brain injury (TBI). Future investigations into the physical, physiological and psychological characteristics related to age, gender and competitive levels of kickboxers are required to enrich the current knowledge and to help create the most suitable training programme. PMID:28566813

  19. Kickboxing review: anthropometric, psychophysiological and activity profiles and injury epidemiology.

    PubMed

    Slimani, M; Chaabene, H; Miarka, B; Franchini, E; Chamari, K; Cheour, F

    2017-06-01

    Kickboxing is one of the modern combat sports. The psychophysiological demands of a kickboxing competition require athletes to achieve high thresholds of several aspects of physical fitness. The aim of the current review is to critically analyse and appraise the kickboxer's anthropometric, physiological, physical and psychological attributes with the activity profile and injury epidemiology in order to provide practical recommendations for training as well as new areas of scientific research. The available information shows that both amateur and elite-level male kickboxers are characterized by a higher proportion of mesomorphy with a well-developed muscle mass and low body fat percentage. While there is some variation in the maximum oxygen uptake of kickboxers, moderate to high cardio-respiratory levels are reported for these athletes. Regardless of kickboxers' level, a high peak and mean anaerobic power output were reported. High-level kickboxing performance also requires well-developed muscle power in both the upper and lower limbs. Psychological factors contribute to success that requires high levels of self-confidence, motivation, dispositional hope and optimism, mental toughness/resiliency, and adaptive perfectionism. Psychological attributes also distinguished successful from less successful kickboxers. The activity-to-rest ratio was higher in elite (1:1) than both amateur and national-level (from 1:2 to 1:5) kickboxers, with no significant differences between rounds (round 1=1:4, and rounds 2 and 3=1:5) as well as between winners and losers in amateur and national-level simulated combats. These particular psychophysiological characteristics and performance aspects of kickboxers influence performance and could serve as guidance for training. Finally, kickboxing is characterized by chronic repetitive head trauma, which causes hypopituitarism due to traumatic brain injury (TBI). Future investigations into the physical, physiological and psychological characteristics related to age, gender and competitive levels of kickboxers are required to enrich the current knowledge and to help create the most suitable training programme.

  20. NC roadway lighting needs assessment, maintenance prioritization tool and performance measures.

    DOT National Transportation Integrated Search

    2013-05-01

    The objectives of this project are to 1) develop an assessment report and summary of accumulated modernization / replacement needs, 2) assess current lighting needs and develop a method to allocate funds at NCDOT Division level, 3) research and docum...

  1. Guidance on data needs, availability, and opportunities for work zone performance measures.

    DOT National Transportation Integrated Search

    2013-03-01

    Current Federal Regulations (23 CFR 630 Subpart J) encourage States to collect and analyze both safety and mobility data to support the initiation and enhancement of agency-level processes and procedures addressing work zone impacts. The purpose of t...

  2. 47 CFR 15.31 - Measurement standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the installation site, such as perimeter protection systems, carrier current systems, and systems... variation of the input power or the radiated signal level of the fundamental frequency component of the... nominal rated supply voltage. For battery operated equipment, the equipment tests shall be performed using...

  3. Executive functions in adolescents with spina bifida: relations with autonomy development and parental intrusiveness.

    PubMed

    Tuminello, Elizabeth R; Holmbeck, Grayson N; Olson, Rick

    2012-01-01

    The current study was part of a larger longitudinal investigation and examined the relation of parent-report and performance measures of executive functioning (EF) with measures of behavioral and emotional autonomy and parental intrusiveness in adolescents with and without spina bifida (SB; n=65 in a comparison sample and 61 in an SB sample; M age=14.55, SD=0.63). For both groups, higher levels of parent-reported EF problems predicted higher levels of observed child dependency and lower levels of teacher-reported intrinsic motivation. Higher scores on performance EF measures predicted lower levels of observed child dependency and observed maternal intrusiveness for both groups. In adolescents with SB only, higher performance EF scores predicted higher intrinsic motivation and emotional autonomy from both mother and father and predicted lower levels of observed paternal intrusiveness. While causal conclusions cannot be drawn, EFs appear to be closely related to autonomy development and parental intrusiveness, particularly for adolescents with SB. These results suggest that the inclusion of EF training in interventions targeting adolescents with SB may be beneficial for autonomy development.

  4. Judging the judges' performance in rhythmic gymnastics.

    PubMed

    Flessas, Konstantinos; Mylonas, Dimitris; Panagiotaropoulou, Georgia; Tsopani, Despina; Korda, Alexandrea; Siettos, Constantinos; Di Cagno, Alessandra; Evdokimidis, Ioannis; Smyrnis, Nikolaos

    2015-03-01

    Rhythmic gymnastics (RG) is an aesthetic event balancing between art and sport that also has a performance rating system (Code of Points) given by the International Gymnastics Federation. It is one of the sports in which competition results greatly depend on the judges' evaluation. In the current study, we explored the judges' performance in a five-gymnast ensemble routine. An expert-novice paradigm (10 international-level, 10 national-level, and 10 novice-level judges) was implemented under a fully simulated procedure of judgment in a five-gymnast ensemble routine of RG using two videos of routines performed by the Greek national team of RG. Simultaneous recordings of two-dimensional eye movements were taken during the judgment procedure to assess the percentage of time spent by each judge viewing the videos and fixation performance of each judge when an error in gymnast performance had occurred. All judge level groups had very modest performance of error recognition on gymnasts' routines, and the best international judges reported approximately 40% of true errors. Novice judges spent significantly more time viewing the videos compared with national and international judges and spent significantly more time fixating detected errors than the other two groups. National judges were the only group that made efficient use of fixation to detect errors. The fact that international-level judges outperformed both other groups, while not relying on visual fixation to detect errors, suggests that these experienced judges probably make use of other cognitive strategies, increasing their overall error detection efficiency, which was, however, still far below optimum.

  5. Social Support and Performance in Complex Organizations.

    DTIC Science & Technology

    1984-01-30

    which subjects’ perceptions of their parents ’ interest in and overprotection of them were related to current social support levels. The findings...support levels are related to subjects’ perceptions of experiences earlier in life. Using the Parental Bonding Instrument, studies were carried out in...indicated clearly that, while parental over-protection is unrelated to scores on the Social Sarason 7 Support Questionnaire there is a highly significant

  6. Adult Brains Don't Fully Overcome Biases that Lead to Incorrect Performance during Cognitive Development: An fMRI Study in Young Adults Completing a Piaget-Like Task

    ERIC Educational Resources Information Center

    Leroux, Gaelle; Spiess, Jeanne; Zago, Laure; Rossi, Sandrine; Lubin, Amelie; Turbelin, Marie-Renee; Mazoyer, Bernard; Tzourio-Mazoyer, Nathalie; Houde, Olivier; Joliot, Marc

    2009-01-01

    A current issue in developmental science is that greater continuity in cognition between children and adults may exist than is usually appreciated in Piaget-like (stages or "staircase") models. This phenomenon has been demonstrated at the behavioural level, but never at the brain level. Here we show with functional magnetic resonance imaging…

  7. Executive Function Is Necessary for Perspective Selection, Not Level-1 Visual Perspective Calculation: Evidence from a Dual-Task Study of Adults

    ERIC Educational Resources Information Center

    Qureshi, Adam W.; Apperly, Ian A.; Samson, Dana

    2010-01-01

    Previous research suggests that perspective-taking and other "theory of mind" processes may be cognitively demanding for adult participants, and may be disrupted by concurrent performance of a secondary task. In the current study, a Level-1 visual perspective task was administered to 32 adults using a dual-task paradigm in which the secondary task…

  8. A Surface Plasmon Enhanced Infrared Photodetector Based on InAs Quantum Dots

    DTIC Science & Technology

    2010-01-01

    mance of QD infrared detector to a level that is compatible to the widely used, conventional MCT infrared detector . Acknowledgment. S.Y.L. gratefully...amenable to large scale fabrication and, more importantly, does not degrade the noise current characteristics of the photodetector. We believe that this...demonstration would bring the performance of QD-based infrared detectors to a level suitable for emerging surveillance and medical diagnostic

  9. Different effects of adding white noise on cognitive performance of sub-, normal and super-attentive school children.

    PubMed

    Helps, Suzannah K; Bamford, Susan; Sonuga-Barke, Edmund J S; Söderlund, Göran B W

    2014-01-01

    Noise often has detrimental effects on performance. However, because of the phenomenon of stochastic resonance (SR), auditory white noise (WN) can alter the "signal to noise" ratio and improve performance. The Moderate Brain Arousal (MBA) model postulates different levels of internal "neural noise" in individuals with different attentional capacities. This in turn determines the particular WN level most beneficial in each individual case-with one level of WN facilitating poor attenders but hindering super-attentive children. The objective of the present study is to find out if added WN affects cognitive performance differently in children that differ in attention ability. Participants were teacher-rated super- (N = 25); normal- (N = 29) and sub-attentive (N = 36) children (aged 8 to 10 years). Two non-executive function (EF) tasks (a verbal episodic recall task and a delayed verbal recognition task) and two EF tasks (a visuo-spatial working memory test and a Go-NoGo task) were performed under three WN levels. The non-WN condition was only used to control for potential differences in background noise in the group testing situations. There were different effects of WN on performance in the three groups-adding moderate WN worsened the performance of super-attentive children for both task types and improved EF performance in sub-attentive children. The normal-attentive children's performance was unaffected by WN exposure. The shift from moderate to high levels of WN had little further effect on performance in any group. The predicted differential effect of WN on performance was confirmed. However, the failure to find evidence for an inverted U function challenges current theories. Alternative explanations are discussed. We propose that WN therapy should be further investigated as a possible non-pharmacological treatment for inattention.

  10. The Simon effect in action: planning and/or on-line control effects?

    PubMed

    Scorolli, Claudia; Pellicano, Antonello; Nicoletti, Roberto; Rubichi, Sandro; Castiello, Umberto

    2015-07-01

    Choice reaction tasks are performed faster when stimulus location corresponds to response location (Simon effect). This spatial stimulus-response compatibility effect affects performance at the level of action planning and execution. However, when response selection is completed before movement initiation, the Simon effect arises only at the planning level. The aim of this study was to ascertain whether when a precocious response selection is requested, the Simon effect can be detected on the kinematics characterizing the online control phase of a non-ballistic movement. Participants were presented with red or green colored squares, which could appear on the right, left, above, or below a central cross. Depending on the square's color, participants had to release one of two buttons (right/left), then reach toward and press a corresponding lateral pad. We found evidence of the Simon effect on both action planning and on-line control. Moreover, the investigation of response conflict at the level of previous trials (i.e., n-1), a factor that might determine interference at the level of the current response, revealed a conflict adaptation process across trials. Results are discussed in terms of current theories concerned with the Simon effect and the distinction between action planning and control. Copyright © 2014 Cognitive Science Society, Inc.

  11. High accuracy attitude reference stabilization and pointing using the Teledyne SDG-5 gyro and the DRIRU II inertial reference unit

    NASA Astrophysics Data System (ADS)

    Green, K. N.; van Alstine, R. L.

    This paper presents the current performance levels of the SDG-5 gyro, a high performance two-axis dynamically tuned gyro, and the DRIRU II redundant inertial reference unit relating to stabilization and pointing applications. Also presented is a discussion of a product improvement program aimed at further noise reductions to meet the demanding requirements of future space defense applications.

  12. Effect of transcranial direct-current stimulation combined with treadmill training on balance and functional performance in children with cerebral palsy: a double-blind randomized controlled trial.

    PubMed

    Duarte, Natália de Almeida Carvalho; Grecco, Luanda André Collange; Galli, Manuela; Fregni, Felipe; Oliveira, Cláudia Santos

    2014-01-01

    Cerebral palsy refers to permanent, mutable motor development disorders stemming from a primary brain lesion, causing secondary musculoskeletal problems and limitations in activities of daily living. The aim of the present study was to determine the effects of gait training combined with transcranial direct-current stimulation over the primary motor cortex on balance and functional performance in children with cerebral palsy. A double-blind randomized controlled study was carried out with 24 children aged five to 12 years with cerebral palsy randomly allocated to two intervention groups (blocks of six and stratified based on GMFCS level (levels I-II or level III).The experimental group (12 children) was submitted to treadmill training and anodal stimulation of the primary motor cortex. The control group (12 children) was submitted to treadmill training and placebo transcranial direct-current stimulation. Training was performed in five weekly sessions for 2 weeks. Evaluations consisted of stabilometric analysis as well as the administration of the Pediatric Balance Scale and Pediatric Evaluation of Disability Inventory one week before the intervention, one week after the completion of the intervention and one month after the completion of the intervention. All patients and two examiners were blinded to the allocation of the children to the different groups. The experimental group exhibited better results in comparison to the control group with regard to anteroposterior sway (eyes open and closed; p<0.05), mediolateral sway (eyes closed; p<0.05) and the Pediatric Balance Scale both one week and one month after the completion of the protocol. Gait training on a treadmill combined with anodal stimulation of the primary motor cortex led to improvements in static balance and functional performance in children with cerebral palsy. Ensaiosclinicos.gov.br/RBR-9B5DH7.

  13. Onsite-effects of dual-hemisphere versus conventional single-hemisphere transcranial direct current stimulation: A functional MRI study.

    PubMed

    Kwon, Yong Hyun; Jang, Sung Ho

    2012-08-25

    We performed functional MRI examinations in six right-handed healthy subjects. During functional MRI scanning, transcranial direct current stimulation was delivered with the anode over the right primary sensorimotor cortex and the cathode over the left primary sensorimotor cortex using dual-hemispheric transcranial direct current stimulation. This was compared to a cathode over the left supraorbital area using conventional single-hemispheric transcranial direct current stimulation. Voxel counts and blood oxygenation level-dependent signal intensities in the right primary sensorimotor cortex regions were estimated and compared between the two transcranial direct current stimulation conditions. Our results showed that dual-hemispheric transcranial direct current stimulation induced greater cortical activities than single-hemispheric transcranial direct current stimulation. These findings suggest that dual-hemispheric transcranial direct current stimulation may provide more effective cortical stimulation than single-hemispheric transcranial direct current stimulation.

  14. Onsite-effects of dual-hemisphere versus conventional single-hemisphere transcranial direct current stimulation

    PubMed Central

    Kwon, Yong Hyun; Jang, Sung Ho

    2012-01-01

    We performed functional MRI examinations in six right-handed healthy subjects. During functional MRI scanning, transcranial direct current stimulation was delivered with the anode over the right primary sensorimotor cortex and the cathode over the left primary sensorimotor cortex using dual-hemispheric transcranial direct current stimulation. This was compared to a cathode over the left supraorbital area using conventional single-hemispheric transcranial direct current stimulation. Voxel counts and blood oxygenation level-dependent signal intensities in the right primary sensorimotor cortex regions were estimated and compared between the two transcranial direct current stimulation conditions. Our results showed that dual-hemispheric transcranial direct current stimulation induced greater cortical activities than single-hemispheric transcranial direct current stimulation. These findings suggest that dual-hemispheric transcranial direct current stimulation may provide more effective cortical stimulation than single-hemispheric transcranial direct current stimulation. PMID:25624815

  15. SEU System Analysis: Not Just the Sum of All Parts

    NASA Technical Reports Server (NTRS)

    Berg, Melanie D.; Label, Kenneth

    2014-01-01

    Single event upset (SEU) analysis of complex systems is challenging. Currently, system SEU analysis is performed by component level partitioning and then either: the most dominant SEU cross-sections (SEUs) are used in system error rate calculations; or the partition SEUs are summed to eventually obtain a system error rate. In many cases, system error rates are overestimated because these methods generally overlook system level derating factors. The problem with overestimating is that it can cause overdesign and consequently negatively affect the following: cost, schedule, functionality, and validation/verification. The scope of this presentation is to discuss the risks involved with our current scheme of SEU analysis for complex systems; and to provide alternative methods for improvement.

  16. [Current Status of Home Visit Programs: Activities and Barriers of Home Care Nursing Services].

    PubMed

    Oh, Eui Geum; Lee, Hyun Joo; Kim, Yukyung; Sung, Ji Hyun; Park, Young Su; Yoo, Jae Yong; Woo, Soohee

    2015-10-01

    The purpose of this study was to examine the current status of home care nursing services provided by community health nurses and to identify barriers to the services. A cross-sectional survey was conducted with three types of community health care nurses. Participants were 257 nurses, 46 of whom were hospital based home care nurses, 176 were community based visiting nurses, and 35 were long term care insurance based visiting nurses. A structured questionnaire on 7 domains of home care nursing services with a 4-point Likert scale was used to measure activities and barriers to care. Data were analyzed using SPSS WIN 21.0 program. Hospital based home care nurses showed a high level of service performance activity in the domain of clinical laboratory tests, medications and injections, therapeutic nursing, and education. Community based visiting nurses had a high level of service performance in the reference domain. Long term care insurance based visiting nurses showed a high level of performance in the service domains of fundamental nursing and counseling. The results show that although health care service provided by the three types of community health nurse overlapped, the focus of the service is differentiated. Therefore, these results suggest that existing home care services will need to be utilized efficiently in the development of a new nursing care service for patients living in the community after hospital discharge.

  17. Poorer divided attention in children born very preterm can be explained by difficulty with each component task, not the executive requirement to dual-task.

    PubMed

    Delane, Louise; Campbell, Catherine; Bayliss, Donna M; Reid, Corinne; Stephens, Amelia; French, Noel; Anderson, Mike

    2017-07-01

    Children born very preterm (VP, ≤ 32 weeks) exhibit poor performance on tasks of executive functioning. However, it is largely unknown whether this reflects the cumulative impact of non-executive deficits or a separable impairment in executive-level abilities. A dual-task paradigm was used in the current study to differentiate the executive processes involved in performing two simple attention tasks simultaneously. The executive-level contribution to performance was indexed by the within-subject cost incurred to single-task performance under dual-task conditions, termed dual-task cost. The participants included 77 VP children (mean age: 7.17 years) and 74 peer controls (mean age: 7.16 years) who completed Sky Search (selective attention), Score (sustained attention) and Sky Search DT (divided attention) from the Test of Everyday Attention for Children. The divided-attention task requires the simultaneous performance of the selective- and sustained-attention tasks. The VP group exhibited poorer performance on the selective- and divided-attention tasks, and showed a strong trend toward poorer performance on the sustained-attention task. However, there were no significant group differences in dual-task cost. These results suggest a cumulative impact of vulnerable lower-level cognitive processes on dual-tasking or divided attention in VP children, and fail to support the hypothesis that VP children show a separable impairment in executive-level abilities.

  18. Extraction-controlled terahertz frequency quantum cascade lasers with a diagonal LO-phonon extraction and injection stage.

    PubMed

    Han, Y J; Li, L H; Grier, A; Chen, L; Valavanis, A; Zhu, J; Freeman, J R; Isac, N; Colombelli, R; Dean, P; Davies, A G; Linfield, E H

    2016-12-12

    We report an extraction-controlled terahertz (THz)-frequency quantum cascade laser design in which a diagonal LO-phonon scattering process is used to achieve efficient current injection into the upper laser level of each period and simultaneously extract electrons from the adjacent period. The effects of the diagonality of the radiative transition are investigated, and a design with a scaled oscillator strength of 0.45 is shown experimentally to provide the highest temperature performance. A 3.3 THz device processed into a double-metal waveguide configuration operated up to 123 K in pulsed mode, with a threshold current density of 1.3 kA/cm2 at 10 K. The QCL structures are modeled using an extended density matrix approach, and the large threshold current is attributed to parasitic current paths associated with the upper laser levels. The simplicity of this design makes it an ideal platform to investigate the scattering injection process.

  19. High-precision radiometric tracking for planetary approach and encounter in the inner solar system

    NASA Technical Reports Server (NTRS)

    Christensen, C. S.; Thurman, S. W.; Davidson, J. M.; Finger, M. H.; Folkner, W. M.

    1989-01-01

    The benefits of improved radiometric tracking data have been studied for planetary approach within the inner Solar System using the Mars Rover Sample Return trajectory as a model. It was found that the benefit of improved data to approach and encounter navigation was highly dependent on the a priori uncertainties assumed for several non-estimated parameters, including those for frame-tie, Earth orientation, troposphere delay, and station locations. With these errors at their current levels, navigational performance was found to be insensitive to enhancements in data accuracy. However, when expected improvements in these errors are modeled, performance with current-accuracy data significantly improves, with substantial further improvements possible with enhancements in data accuracy.

  20. Mississippi River-Gulf Outlet, Louisiana, Field Data Report

    DTIC Science & Technology

    1990-08-01

    Fisackerly, T. L. Fagerburg, H. A . Benson, and J. W. Parman, EPB. Data reduction was performed by Ms. C . J. Coleman, EPB, and Mr. Fagerburg. Laboratory...Measurements consisted of the following: a . Water levels recorded at six locations. b. Current speed and direction at three ranges. c . Suspended sediment...sampling tubing was attached to the solid suspension bar at the same elevation as the current meter and was pointed into the flow. A 12-v d- c pump was

  1. Performance Issues for a Changing Electric Power Industry

    EIA Publications

    1995-01-01

    Provides an overview of some of the factors affecting reliability within the electric bulk power system. Historical and projected data related to reliability issues are discussed on a national and regional basis. Current research on economic considerations associated with reliability levels is also reviewed.

  2. Operations analysis (study 2.1). Payload designs for space servicing, addendum

    NASA Technical Reports Server (NTRS)

    Wolfe, R. R.

    1974-01-01

    Space replaceable units and payload configurations are revised to reflect increased levels of redundancy to be more consistent with current design practices. A reassessment of expendable payload design reliabilities was performed to provide a common basis for comparison with space serviceable configurations.

  3. The road to successful ITS software acquisition. Volume 2, Software acquisition process reference guide

    DOT National Transportation Integrated Search

    2000-12-01

    The current performance-related specifications (PRS) methodology has been under development by the Federal Highway Administration (FHWA) for several years and has now reached a level at which it can be implemented by State highway agencies. PRS for h...

  4. Cumulative Development of Attentional Theory.

    ERIC Educational Resources Information Center

    Posner, Michael I.

    1982-01-01

    Describes current work in selective attention within a framework of research conducted over the past century. Presents evidence that findings at the level of performance, subjective experience, and neural systems can be linked, even though these findings are not yet reducible to a single theory. (Author/GC)

  5. Evaluation of the Superpave Gyratory Compactor for Low Volume Roads

    DOT National Transportation Integrated Search

    2000-06-01

    There is evidence that some Kansas mixes, which have performed well in the past, will not meet the currently proposed design requirements for a Superpave level I mix. The major problem is low voids in the mineral aggregate (VMA). The major reasons fo...

  6. Elucidation and Optimization of Resistive Random Access Memory Switching Behavior for Advanced Computing Applications

    NASA Astrophysics Data System (ADS)

    Alamgir, Zahiruddin

    RRAM has recently emerged as a strong candidate for non-volatile memory (NVM). Beyond memory applications, RRAM holds promise for use in performing logic functions, mimicking neuromorphic activities, enabling multi-level switching, and as one of the key elements of hardware based encryption or signal processing systems. It has been shown previously that RRAM resistance levels can be changed by adjusting compliance current or voltage level. This characteristic makes RRAM suitable for use in setting the synaptic weight in neuromorphic computing circuits. RRAM is also considered as a key element in hardware encryption systems, to produce unique and reproducible signals. However, a key challenge to implement RRAM in these applications is significant cycle to cycle performance variability. We sought to develop RRAM that can be tuned to different resistance levels gradually, with high reliability, and low variability. To achieve this goal, we focused on elucidating the conduction mechanisms underlying the resistive switching behavior for these devices. Electrical conduction mechanisms were determined by curve fitting I-V data using different current conduction equations. Temperature studies were also performed to corroborate these data. It was found that Schottky barrier height and width modulation was one of the key parameters that could be tuned to achieve different resistance levels, and for switching resistance states, primarily via oxygen vacancy movement. Oxygen exchange layers with different electronegativity were placed between top electrode and the oxide layer of TaOx devices to determine the effect of oxygen vacancy concentrations and gradients in these devices. It was found that devices with OELs with lower electronegativity tend to yield greater separation in the OFF vs. ON state resistance levels. As an extension of this work, TaOx based RRAM with Hf as the OEL was fabricated and could be tuned to different resistance level using pulse width and height modulation, yielding excellent uniformity and reliability. These findings improve our understanding of conduction within TaO x-based RRAM devices, providing a physical basis for switching in these devices. The value of this work lies in the demonstration of devices with excellent performance and demonstrated devices constitute a significant step toward real-world applications.

  7. Modeling and simulation of the shading effect on the performance of a photovoltaic module in the presence of the bypass diode.

    NASA Astrophysics Data System (ADS)

    Zebiri, Mohamed; Mediouni, Mohamed; Idadoub, Hicham

    2018-05-01

    In photovoltaic renewable energy production systems where production is dependent on weather conditions, maintaining production at a suitable level is more than essential. The shading effect in photovoltaic panels affects the production of electrical energy by reducing it or even causing the destruction of some or all of the panels. To circumvent this problem, among the solutions proposed in the literature we find the use of by-pass diode and anti-return diode to minimize these consequences.In this paper we present a simulation under Matlab-Simulink of the shading effect and we compare the current voltages characteristics (I-V) and power voltage (P-V) of a photovoltaic system for different irradiations in the presence and absence of diode by -pass. For modeling, we will use the diode model and the Lambert W-function to solve the implicit equation of the output current. This method allows you to analyze the performance of a panel at different shading levels.

  8. Control of epitaxial defects for optimal AlGaN/GaN HEMT performance and reliability

    NASA Astrophysics Data System (ADS)

    Green, D. S.; Gibb, S. R.; Hosse, B.; Vetury, R.; Grider, D. E.; Smart, J. A.

    2004-12-01

    High-quality GaN epitaxy continues to be challenged by the lack of matched substrates. Threading dislocations that result from heteroepitaxy are responsible for leakage currents, trapping effects, and may adversely affect device reliability. We have studied the impact of AlN nucleation conditions on the density and character of threading dislocations on SiC substrates. Variation of the nucleation temperature, V/III ratio, and thickness are seen to have a dramatic effect on the balance between edge, screw and mixed character dislocation densities. Electrical and structural properties have been assessed by AFM and XRD on a material level and through DC and RF performance at the device level. The ratio between dislocation characteristics has been established primarily through comparison of symmetric and asymmetric XRD rocking curve widths. The effect of each dislocation type on leakage current, RF power and reliability at 2 GHz, the targeted band for cell phone infrastructure applications, is discussed.

  9. State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes—The Need for Novel Non-Invasive Techniques

    PubMed Central

    Greene, Jacob; Louis, Julien; Korostynska, Olga; Mason, Alex

    2017-01-01

    Muscle glycogen levels have a profound impact on an athlete’s sporting performance, thus measurement is vital. Carbohydrate manipulation is a fundamental component in an athlete’s lifestyle and is a critical part of elite performance, since it can provide necessary training adaptations. This paper provides a critical review of the current invasive and non-invasive methods for measuring skeletal muscle glycogen levels. These include the gold standard muscle biopsy, histochemical analysis, magnetic resonance spectroscopy, and musculoskeletal high frequency ultrasound, as well as pursuing future application of electromagnetic sensors in the pursuit of portable non-invasive quantification of muscle glycogen. This paper will be of interest to researchers who wish to understand the current and most appropriate techniques in measuring skeletal muscle glycogen. This will have applications both in the lab and in the field by improving the accuracy of research protocols and following the physiological adaptations to exercise. PMID:28241495

  10. Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering.

    PubMed

    Beck-Broichsitter, Benedicta E; Daschner, Frank; Christofzik, David W; Knöchel, Reinhard; Wiltfang, Jörg; Becker, Stephan T

    2015-03-01

    The metabolic processes that regulate bone healing and bone induction in tissue engineering models are not fully understood. Eddy current excitation is widely used in technical approaches and in the food industry. The aim of this study was to establish eddy current excitation for monitoring metabolic processes during heterotopic osteoinduction in vivo. Hydroxyapatite scaffolds were implanted into the musculus latissimus dorsi of six rats. Bone morphogenetic protein 2 (BMP-2) was applied 1 and 2 weeks after implantation. Weekly eddy current excitation measurements were performed. Additionally, invasive pH measurements were obtained from the scaffolds using fiber optic detection devices. Correlations between the eddy current measurements and the metabolic values were calculated. The eddy current measurements and pH values decreased significantly in the first 2 weeks of the study, followed by a steady increase and stabilization at higher levels towards the end of the study. The measurement curves and statistical evaluations indicated a significant correlation between the resonance frequency values of the eddy current excitation measurements and the observed pH levels (p = 0.0041). This innovative technique was capable of noninvasively monitoring metabolic processes in living tissues according to pH values, showing a direct correlation between eddy current excitation and pH in an in vivo tissue engineering model.

  11. High efficiency thermionic converter studies

    NASA Technical Reports Server (NTRS)

    Huffman, F. N.; Sommer, A. H.; Balestra, C. L.; Briere, D. P.; Oettinger, P. E.

    1976-01-01

    The objective is to improve thermionic converter performance by means of reduced interelectrode losses, greater emitter capabilities, and lower collector work functions until the converter performance level is suitable for out-of-core space reactors and radioisotope generators. Electrode screening experiments have identified several promising collector materials. Back emission work function measurements of a ZnO collector in a thermionic diode have given values less than 1.3 eV. Diode tests were conducted over the range of temperatures of interest for space power applications. Enhanced mode converter experiments have included triodes operated in both the surface ionization and plasmatron modes. Pulsed triodes were studied as a function of pulse length, pulse potential, inert gas fill pressure, cesium pressure, spacing, emitter temperature and collector temperature. Current amplifications (i.e., mean output current/mean grid current) of several hundred were observed up to output current densities of one amp/sq cm. These data correspond to an equivalent arc drop less than 0.1 eV.

  12. Performance management in healthcare: a critical analysis.

    PubMed

    Hewko, Sarah J; Cummings, Greta G

    2016-01-01

    Purpose - The purpose of this paper is to explore the underlying theoretical assumptions and implications of current micro-level performance management and evaluation (PME) practices, specifically within health-care organizations. PME encompasses all activities that are designed and conducted to align employee outputs with organizational goals. Design/methodology/approach - PME, in the context of healthcare, is analyzed through the lens of critical theory. Specifically, Habermas' theory of communicative action is used to highlight some of the questions that arise in looking critically at PME. To provide a richer definition of key theoretical concepts, the authors conducted a preliminary, exploratory hermeneutic semantic analysis of the key words "performance" and "management" and of the term "performance management". Findings - Analysis reveals that existing micro-level PME systems in health-care organizations have the potential to create a workforce that is compliant, dependent, technically oriented and passive, and to support health-care systems in which inequalities and power imbalances are perpetually reinforced. Practical implications - At a time when the health-care system is under increasing pressure to provide high-quality, affordable services with fewer resources, it may be wise to investigate new sector-specific ways of evaluating and managing performance. Originality/value - In this paper, written for health-care leaders and health human resource specialists, the theoretical assumptions and implications of current PME practices within health-care organizations are explored. It is hoped that readers will be inspired to support innovative PME practices within their organizations that encourage peak performance among health-care professionals.

  13. Acute care hospitals' accountability to provincial funders.

    PubMed

    Kromm, Seija K; Ross Baker, G; Wodchis, Walter P; Deber, Raisa B

    2014-09-01

    Ontario's acute care hospitals are subject to a number of tools, including legislation and performance measurement for fiscal accountability and accountability for quality. Examination of accountability documents used in Ontario at the government, regional and acute care hospital levels reveals three trends: (a) the number of performance measures being used in the acute care hospital sector has increased significantly; (b) the focus of the health system has expanded from accountability for funding and service volumes to include accountability for quality and patient safety; and (c) the accountability requirements are misaligned at the different levels. These trends may affect the success of the accountability approach currently being used. Copyright © 2014 Longwoods Publishing.

  14. Level of Perception of Individualized Care and Satisfaction With Nursing in Orthopaedic Surgery Patients.

    PubMed

    Tekin, Fatma; Findik, Ummu Yildiz

    2015-01-01

    Lately, individualized nursing care and patient satisfaction are important and current issues being discussed. But there is not enough information for patients undergoing orthopaedic surgery. The aim of this study was to determine the individualized care perception and satisfaction in nursing care levels in orthopaedic surgery patients. This descriptive cross-sectional study was conducted with 156 patients who underwent orthopaedic surgery. Data were collected using the personal information form, the Individualized Care Scale, and the Newcastle Satisfaction With Nursing Scale. The Spearman correlation analysis and descriptive statistics were performed. The mean individualized care and satisfaction with nursing care scores were found to be close to the preset maximum value, and it was determined that an increase in the level of awareness about nursing interventions and the level of perceived individualized care caused an increase in satisfaction levels regarding nursing care. Nurses should recognize the importance of performing individualized care in order to increase the level of satisfaction with nursing care in orthopaedic surgery patients.

  15. Improvements in analysis techniques for segmented mirror arrays

    NASA Astrophysics Data System (ADS)

    Michels, Gregory J.; Genberg, Victor L.; Bisson, Gary R.

    2016-08-01

    The employment of actively controlled segmented mirror architectures has become increasingly common in the development of current astronomical telescopes. Optomechanical analysis of such hardware presents unique issues compared to that of monolithic mirror designs. The work presented here is a review of current capabilities and improvements in the methodology of the analysis of mechanically induced surface deformation of such systems. The recent improvements include capability to differentiate surface deformation at the array and segment level. This differentiation allowing surface deformation analysis at each individual segment level offers useful insight into the mechanical behavior of the segments that is unavailable by analysis solely at the parent array level. In addition, capability to characterize the full displacement vector deformation of collections of points allows analysis of mechanical disturbance predictions of assembly interfaces relative to other assembly interfaces. This capability, called racking analysis, allows engineers to develop designs for segment-to-segment phasing performance in assembly integration, 0g release, and thermal stability of operation. The performance predicted by racking has the advantage of being comparable to the measurements used in assembly of hardware. Approaches to all of the above issues are presented and demonstrated by example with SigFit, a commercially available tool integrating mechanical analysis with optical analysis.

  16. Extended performance technology study 30-cm thruster

    NASA Technical Reports Server (NTRS)

    Beattie, J. R.

    1983-01-01

    The extended performance technology study was an investigation of advanced discharge chambers and thruster components that were designed to operate under conditions which result in an increase in the thrust and thrust to power ratio of the state of the art J-series thruster. The high level of performance was achieved by a discharge chamber that employs a ring cusp magnetic confinement arrangement and a three grid ion extraction assembly. It is shown that the ring cusp magnetic field geometry confines the plasma to the volume immediately adjacent to the ion extraction assembly. A high emission current hollow cathode that demonstrated operation at an emission current as high as J sub E = 40 A, and measurements which show the breakdown voltage of individual sections of the J-series propellant flow electrical isolator is about 340 V per section are investigated.

  17. Current-induced dissipation in spectral wave models

    NASA Astrophysics Data System (ADS)

    Rapizo, H.; Babanin, A. V.; Provis, D.; Rogers, W. E.

    2017-03-01

    Despite many recent developments of the parameterization for wave dissipation in spectral models, it is evident that when waves propagate onto strong adverse currents the rate of energy dissipation is not properly estimated. The issue of current-induced dissipation is studied through a comprehensive data set in the tidal inlet of Port Phillip Heads, Australia. The wave parameters analyzed are significantly modulated by the tidal currents. Wave height in conditions of opposing currents (ebb tide) can reach twice the offshore value, whereas during coflowing currents (flood), it can be reduced to half. The wind-wave model SWAN is able to reproduce the tide-induced modulation of waves and the results show that the variation of currents is the dominant factor in modifying the wave field. In stationary simulations, the model provides an accurate representation of wave height for slack and flood tides. During ebb tides, wave energy is highly overestimated over the opposing current jet. None of the four parameterizations for wave dissipation tested performs satisfactorily. A modification to enhance dissipation as a function of the local currents is proposed. It consists of the addition of a factor that represents current-induced wave steepening and it is scaled by the ratio of spectral energy to the threshold breaking level. The new term asymptotes to the original form as the current in the wave direction tends to zero. The proposed modification considerably improves wave height and mean period in conditions of adverse currents, whereas the good model performance in coflowing currents is unaltered.

  18. Transcranial oscillatory direct current stimulation during sleep improves declarative memory consolidation in children with attention-deficit/hyperactivity disorder to a level comparable to healthy controls.

    PubMed

    Prehn-Kristensen, Alexander; Munz, Manuel; Göder, Robert; Wilhelm, Ines; Korr, Katharina; Vahl, Wiebke; Wiesner, Christian D; Baving, Lioba

    2014-01-01

    Slow oscillations (<1 Hz) during slow wave sleep (SWS) promote the consolidation of declarative memory. Children with attention-deficit/hyperactivity disorder (ADHD) have been shown to display deficits in sleep-dependent consolidation of declarative memory supposedly due to dysfunctional slow brain rhythms during SWS. Using transcranial oscillating direct current stimulation (toDCS) at 0.75 Hz, we investigated whether an externally triggered increase in slow oscillations during early SWS elevates memory performance in children with ADHD. 12 children with ADHD underwent a toDCS and a sham condition in a double-blind crossover study design conducted in a sleep laboratory. Memory was tested using a 2D object-location task. In addition, 12 healthy children performed the same memory task in their home environment. Stimulation enhanced slow oscillation power in children with ADHD and boosted memory performance to the same level as in healthy children. These data indicate that increasing slow oscillation power during sleep by toDCS can alleviate declarative memory deficits in children with ADHD. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  19. The 1981 current research on aviation weather (bibliography)

    NASA Technical Reports Server (NTRS)

    Daniel, J.; Frost, W.

    1982-01-01

    Current and ongoing research programs related to various areas of aviation meteorology are presented. Literature searches of major abstract publications, were conducted. Research project managers of various government agencies involved in aviation meteorology research provided a list of current research project titles and managers, supporting organizations, performing organizations, the principal investigators, and the objectives. These are tabulated under the headings of advanced meteorological instruments, forecasting, icing, lightning and atmospheric electricity; fog, visibility, and ceilings; low level wind shear, storm hazards/severe storms, turbulence, winds, and ozone and other meteorological parameters. This information was reviewed and assembled into a bibliography providing a current readily useable source of information in the area of aviation meteorology.

  20. Annual Status Report (FY2017): Performance Assessment for the Disposal of Low-Level Waste in the 200 East Area Burial Grounds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, Will E.; Mehta, S.; Nell, R. M.

    This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. The estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-7301). The estimates are compared with performance objectives defined in U.S. Department of Energy (DOE) requirements (DOE O 435.1 Chg 1,2 and companion documents DOE M 435.1-1 Chg 13 and DOE G 435.1-14). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-00635) and waste acceptance practices continue to be sufficient to maintain compliance withmore » performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, which indicate potential impacts well below performance objectives. Therefore, future compliance with DOE O 435.1 Chg 1 is expected.« less

  1. Annual Status Report (FY2017): Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, Will E; Nell, R. M.; Mehta, S.

    This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 West Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-EP-06451). These estimates are compared with performance objectives defined in U.S. Department of Energy (DOE) requirements (DOE O 435.1 Chg 12 and its companion documents DOE M 435.1-1 Chg 13 and DOE G 435.1-14). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-00635) and waste acceptance practices continue to be sufficient to maintain compliancemore » with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, which indicate potential impacts well below performance objectives. Therefore, future compliance with DOE O 435.1 Chg 1 is expected.« less

  2. Extending BPM Environments of Your Choice with Performance Related Decision Support

    NASA Astrophysics Data System (ADS)

    Fritzsche, Mathias; Picht, Michael; Gilani, Wasif; Spence, Ivor; Brown, John; Kilpatrick, Peter

    What-if Simulations have been identified as one solution for business performance related decision support. Such support is especially useful in cases where it can be automatically generated out of Business Process Management (BPM) Environments from the existing business process models and performance parameters monitored from the executed business process instances. Currently, some of the available BPM Environments offer basic-level performance prediction capabilities. However, these functionalities are normally too limited to be generally useful for performance related decision support at business process level. In this paper, an approach is presented which allows the non-intrusive integration of sophisticated tooling for what-if simulations, analytic performance prediction tools, process optimizations or a combination of such solutions into already existing BPM environments. The approach abstracts from process modelling techniques which enable automatic decision support spanning processes across numerous BPM Environments. For instance, this enables end-to-end decision support for composite processes modelled with the Business Process Modelling Notation (BPMN) on top of existing Enterprise Resource Planning (ERP) processes modelled with proprietary languages.

  3. A numerical study of the acoustic radiation due to eddy current-cryostat interactions.

    PubMed

    Wang, Yaohui; Liu, Feng; Zhou, Xiaorong; Li, Yu; Crozier, Stuart

    2017-06-01

    To investigate the acoustic radiation due to eddy current-cryostat interactions and perform a qualitative analysis on noise reduction methods. In order to evaluate the sound pressure level (SPL) of the eddy current induced warm bore wall vibration, a Finite Element (FE) model was created to simulate the noises from both the warm bore wall vibration and the gradient coil assembly. For the SPL reduction of the warm bore wall vibration, we first improved the active shielding of the gradient coil, thus reducing the eddy current on the warm bore wall. A damping treatment was then applied to the warm bore wall to control the acoustic radiation. Initial simulations show that the SPL of the warm bore wall is higher than that of the gradient assembly with typical design shielding ratios at many frequencies. Subsequent simulation results of eddy current control and damping treatment application show that the average SPL reduction of the warm bore wall can be as high as 9.6 dB, and even higher in some frequency bands. Combining eddy current control and suggested damping scheme, the noise level in a MRI system can be effectively reduced. © 2017 American Association of Physicists in Medicine.

  4. Ecophysiology of cognition: How do environmentally induced changes in physiology affect cognitive performance?

    PubMed

    Maille, Audrey; Schradin, Carsten

    2017-05-01

    Cognitive performance is based on brain functions, which have energetic demands and are modulated by physiological parameters such as metabolic hormones. As both environmental demands and environmental energy availability change seasonally, we propose that cognitive performance in free-living animals might also change seasonally due to phenotypic plasticity. This is part of an emerging research field, the 'ecophysiology of cognition': environmentally induced changes in physiological traits, such as blood glucose and hormone levels, are predicted to influence cognitive performance in free-living animals. Energy availability for the brain might change, and as such cognition, with changing energetic demands (e.g. reproduction) and changes of energy availability in the environment (e.g. winter, drought). Individuals spending more energy than they can currently obtain from their environment (allostatic overload type I) are expected to trade off energy investment between cognition and other life-sustaining processes or even reproduction. Environmental changes reducing energy availability might thus impair cognition. However, selection pressures such as predation risk, mate choice or social demands may act on the trade-off between energy saving and cognition. We assume that different environmental conditions can lead to three different trade-off outcomes: cognitive impairment, resilience or enhancement. Currently we cannot understand these trade-offs, because we lack information about changes in cognitive performance due to seasonal changes in energy availability and both the resulting changes in homeostasis (for example, blood glucose levels) and the associated changes in the mechanisms of allostasis (for example, hormone levels). Additionally, so far we know little about the fitness consequences of individual variation in cognitive performance. General cognitive abilities, such as attention and associative learning, might be more important in determining fitness than complex and specialized cognitive abilities, and easier to use for comparative study in a large number of species. We propose to study seasonal changes in cognitive performance depending on energy availability in populations facing different predation risks, and the resulting fitness consequences. © 2016 Cambridge Philosophical Society.

  5. Design, performance, and economics of 50-kW and 500-kW vertical axis wind turbines

    NASA Astrophysics Data System (ADS)

    Schienbein, L. A.; Malcolm, D. J.

    1983-11-01

    A review of the development and performance of the DAF Indal 50-kW vertical axis Darrieus wind turbine shows that a high level of technical development and reliability has been achieved. Features of the drive train, braking and control systems are discussed and performance details are presented. Details are also presented of a 500-kW VAWT that is currently in production. A discussion of the economics of both the 50-kW and 500-kW VAWTs is included, showing the effects of charge rate, installed cost, operating cost, performance, and efficiency.

  6. Association of serum electrolytes and smoking with salivary gland stone formation.

    PubMed

    Yiu, A J; Kalejaiye, A; Amdur, R L; Todd Hesham, H N; Bandyopadhyay, B C

    2016-06-01

    To further define potential factors that may contribute to stone formation in salivary glands (sialolithiasis), a retrospective chart review was performed of patients diagnosed with sialolithiasis between March 1, 1998 and February 29, 2012. Information on salivary gland stone number, location and size, medical history, medications, and serum electrolyte levels were collected. Associations between electrolyte levels and stone characteristics (such as stone number and size) were examined. Fifty-nine patients were identified; their median age was 58 years (range 25-89 years) and most were male (95%). Salivary stones were most commonly located in the submandibular glands (83%). Thirty-five patients (59%) had a smoking history, with 16 (27%) reported as current smokers. There was a significant association between current smoker status and stone size (mean largest stone size 12.4±8.8mm vs. 7.5±4.8mm in current smokers vs. non-smokers; P=0.03). Serum sodium levels (r=0.32, P=0.014) and serum potassium levels (r=0.31, P=0.017) showed significant positive correlations with stone size. While the aetiology of sialolithiasis remains unclear, smoking (which can contribute to reduced saliva flow) and higher serum sodium levels (which can reflect volume depletion) are associated with larger salivary stones. Published by Elsevier Ltd.

  7. Association of serum electrolytes and smoking with salivary gland stone formation

    PubMed Central

    Yiu, A. J.; Kalejaiye, A.; Amdur, R. L.; Hesham, H. N. Todd; Bandyopadhyay, B. C.

    2016-01-01

    To further define potential factors that may contribute to stone formation in salivary glands (sialolithiasis), a retrospective chart review was performed of patients diagnosed with sialolithiasis between March 1, 1998 and February 29, 2012. Information on salivary gland stone number, location, and size, medical history, medications, and serum electrolyte levels were collected. Associations between electrolyte levels and stone characteristics (such as stone number and size) were examined. Fifty-nine patients were identified; their median age was 58 years (range 25–89 years) and most were male (95%). Salivary stones were most commonly located in the submandibular glands (83%). Thirty-five patients (59%) had a smoking history, with 16 (27%) reported as current smokers. There was a significant association between current smoker status and stone size (mean largest stone size 12.4 ± 8.8 mm vs. 7.5 ± 4.8 mm in current smokers vs. non-smokers; P = 0.03). Serum sodium levels (r = 0.32, P = 0.014) and serum potassium levels (r = 0.31, P = 0.017) showed significant positive correlations with stone size. While the etiology of sialolithiasis remains unclear, smoking (which can contribute to reduced saliva flow) and higher serum sodium levels (which can reflect volume depletion) are associated with larger salivary stones. PMID:26969301

  8. Photoinduced current transient spectroscopy of deep levels and transport mechanisms in iron-doped GaN thin films grown by low pressure-metalorganic vapor phase epitaxy

    NASA Astrophysics Data System (ADS)

    Muret, P.; Pernot, J.; Azize, M.; Bougrioua, Z.

    2007-09-01

    Electrical transport and deep levels are investigated in GaN:Fe layers epitaxially grown on sapphire by low pressure metalorganic vapor phase epitaxy. Photoinduced current transient spectroscopy and current detected deep level spectroscopy are performed between 200 and 650 K on three Fe-doped samples and an undoped sample. A detailed study of the detected deep levels assigns dominant centers to a deep donor 1.39 eV below the conduction band edge EC and to a deep acceptor 0.75 eV above the valence band edge EV at low electric field. A strong Poole-Frenkel effect is evidenced for the donor. Schottky diodes characteristics and transport properties in the bulk GaN:Fe layer containing a homogenous concentration of 1019 Fe/cm3 are typical of a compensated semiconductor. They both indicate that the bulk Fermi level is located typically 1.4 eV below EC, in agreement with the neutrality equation and dominance of the deep donor concentration. This set of results demonstrates unambiguously that electrical transport in GaN:Fe is governed by both types, either donor or acceptor, of the iron impurity, either substitutional in gallium sites or associated with other defects.

  9. Advanced photovoltaic solar array development

    NASA Technical Reports Server (NTRS)

    Kurland, Richard M.; Stella, Paul

    1989-01-01

    Phase 2 of the Advanced Photovoltaic Solar Array (APSA) program, started in mid-1987, is currently in progress to fabricate prototype wing hardware that will lead to wing integration and testing in 1989. The design configuration and key details are reviewed. A status of prototype hardware fabricated to date is provided. Results from key component-level tests are discussed. Revised estimates of array-level performance as a function of solar cell device technology for geosynchronous missions are given.

  10. Performance of the Volumetric Diffusive Respirator at Altitude

    DTIC Science & Technology

    2014-08-18

    information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM...increased by 30-40%. Tidal volume remained within 15% of sea level values. Respiratory rate fell, while inspiratory time increased and high frequency...altitude, positive end expiratory pressure and peak inspiratory pressure were increased by 30-40%. Tidal volume remained within 15% of sea level

  11. Joint DoD Standardization and Data/Configuration Management Conference (1991) Conducting Business Under the DMR

    DTIC Science & Technology

    1991-05-17

    items. These drawings represent the highest level of design disclo- sure. 4. APPROVAL DATE 5. OFFICE OF PRIMARY RESPONSIBILITY (OPR) 6a. DTIC APPLICABLE...the contract or purchase order. Product drawings and associated lists shall provide the design disclosure information necessary to enable a...performance characteristics duplicate those of the original design . These drawings shall: a. Reflect the end-product at its current level of design

  12. Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

    PubMed

    Ruhparwar, Arjang; Er, Fikret; Martin, Ulrich; Radke, Kristin; Gruh, Ina; Niehaus, Michael; Karck, Matthias; Haverich, Axel; Hoppe, Uta C

    2007-02-01

    Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyocytes into cells with a pacemaker-like phenotype. Neuregulin-1 (alpha- and beta-isoform) or the cAMP was added to fresh cell cultures of murine embryonic cardiomyocytes. Quantitative northern blot analysis and flowcytometry were performed to detect the expression of connexins 40, 43 and 45. Patch clamp recordings in the whole cell configuration were performed to determine current density of I (f), a characteristic ion current of pacemaker cells. Fetal cardiomyocytes without supplement of neuregulin or cAMP served as control group. Neuregulin and cAMP significantly increased mRNA levels of connexin 40 (Cx-40), a marker of the early differentiating conduction system in mice. On the protein level, flowcytometry revealed no significant differences between treated and untreated groups with regard to the expression of connexins 40, 43 and 45. Treatment with cAMP (11.2 +/- 2.24 pA/pF; P < 0.001) and neuregulin-1-beta (6.23 +/- 1.07 pA/pF; P < 0.001) significantly increased the pacemaker current density compared to control cardiomyocytes (1.76 +/- 0.49 pA/pF). Our results indicate that neuregulin-1 and cAMP possess the capacity to cause significant transformation of a mixed population of fetal cardiomyocytes into cardiac pacemaker-like cells as shown by electrophysiology and increase of Cx-40 mRNA. This method may allow the development of a biological cardiac pacemaker system when applied to adult or embryonic stem cells.

  13. National Plan for Graduate Studies.

    ERIC Educational Resources Information Center

    Ministry of Education and Culture, Brasilia (Brazil).

    The Brazilian National Plan for Graduate Studies aims at achieving a combination of training activities at the graduate level to be developed at the various institutions of higher education and research. The current situation is reviewed in terms of stabilization, performance, and development problems. Objectives and general directives include:…

  14. The Enterococcus QPCR Method for Recreational Water Quality Testing: Testing Background, Performance and Issues

    EPA Science Inventory

    Currently accepted culture-based monitoring methods for fecal indicator bacteria in surface waters take at least 24 hr to determine if unacceptable levels of fecal pollution have reached our recreational beaches. During this waiting period changing water conditions may result eit...

  15. Developing Stem Talent among Diverse Learners

    ERIC Educational Resources Information Center

    Roberts, Julia Link

    2014-01-01

    Currently, the U.S. is not stacking up in educating students in STEM disciplines. "America lags in providing top-level schooling in STEM fields…, and this may jeopardize future economic growth, job creation, and international competitiveness" (Smarick, 2013, p. 12). International assessments of student performance, including the Program…

  16. Examining the Relationship between Math Scores and English Language Proficiency

    ERIC Educational Resources Information Center

    Henry, Denfield L.; Nistor, Nicolae; Baltes, Beate

    2016-01-01

    Multiple studies propose that English proficiency dictates English language learners' (ELLs) performances on mathematics assessments. The current study investigates the predictive power of English proficiency on mathematics scores, while controlling for gender, socioeconomic status (SES), and grade level among ELLs at a south Florida elementary…

  17. Competency-Based Adult Education Research and Innovation Catalog.

    ERIC Educational Resources Information Center

    Bureau of Occupational and Adult Education (DHEW/OE), Washington, DC. Div. of Adult Education.

    This document contains abstracts describing competency-based programs related to the Adult Performance Level (APL) project and adult education. The catalog is divided into two sections: state program implementation and local program implementation. The first section describes programs and research projects currently active in Alabama, California,…

  18. Can IGF-I polymorphism affect power and endurance athletic performance?

    PubMed

    Ben-Zaken, Sigal; Meckel, Yoav; Nemet, Dan; Eliakim, Alon

    2013-10-01

    Insulin-like growth factor-I (IGF-I) plays a key role in exercise-associated muscle growth and development. The regulatory region of the promoter of the IGF-I gene is labile, but changes in this region were studied mostly in the elderly and in relation to pathological states. C-1245T (rs35767) is a genetic variation in the promoter region of the IGF-I gene. The minor allele T was found to be associated with higher circulating IGF-I levels, and possibly with increased muscle mass. The aim of the current study was to analyze the frequency distribution of C-1245T SNP in athletic and nonathletic Israeli populations. One hundred and sixty-five athletes (78 endurance-type athletes, and 87 power-type athletes) and 159 nonathletic healthy individuals participated in the current study. Genomic DNA was extracted from peripheral EDTA treated anti-coagulated blood using a standard protocol. Genotyping of the IGF1 C-1245T polymorphism was performed using polymerase chain reaction (PCR). We found that the endurance and power athletes' allele and genotype frequencies were significantly different from those of the control group. Only 4.8% of the athletes were TT carriers, but none of the controls carried this genotype. The T allele was found to be more frequent in the top-level power athletes (international and Olympic level) compared to national level athletes, but such a difference was not found in endurance athletes. Our findings suggest a possible contribution for the relatively rare IGF-I TT genotype to endurance performance, and in particular to power sport excellence in Israeli athletes. © 2013.

  19. Enhancing team-sport athlete performance: is altitude training relevant?

    PubMed

    Billaut, François; Gore, Christopher J; Aughey, Robert J

    2012-09-01

    Field-based team sport matches are composed of short, high-intensity efforts, interspersed with intervals of rest or submaximal exercise, repeated over a period of 60-120 minutes. Matches may also be played at moderate altitude where the lower oxygen partial pressure exerts a detrimental effect on performance. To enhance run-based performance, team-sport athletes use varied training strategies focusing on different aspects of team-sport physiology, including aerobic, sprint, repeated-sprint and resistance training. Interestingly, 'altitude' training (i.e. living and/or training in O(2)-reduced environments) has only been empirically employed by athletes and coaches to improve the basic characteristics of speed and endurance necessary to excel in team sports. Hypoxia, as an additional stimulus to training, is typically used by endurance athletes to enhance performance at sea level and to prepare for competition at altitude. Several approaches have evolved in the last few decades, which are known to enhance aerobic power and, thus, endurance performance. Altitude training can also promote an increased anaerobic fitness, and may enhance sprint capacity. Therefore, altitude training may confer potentially-beneficial adaptations to team-sport athletes, which have been overlooked in contemporary sport physiology research. Here, we review the current knowledge on the established benefits of altitude training on physiological systems relevant to team-sport performance, and conclude that current evidence supports implementation of altitude training modalities to enhance match physical performances at both sea level and altitude. We hope that this will guide the practice of many athletes and stimulate future research to better refine training programmes.

  20. Gaming is related to enhanced working memory performance and task-related cortical activity.

    PubMed

    Moisala, M; Salmela, V; Hietajärvi, L; Carlson, S; Vuontela, V; Lonka, K; Hakkarainen, K; Salmela-Aro, K; Alho, K

    2017-01-15

    Gaming experience has been suggested to lead to performance enhancements in a wide variety of working memory tasks. Previous studies have, however, mostly focused on adult expert gamers and have not included measurements of both behavioral performance and brain activity. In the current study, 167 adolescents and young adults (aged 13-24 years) with different amounts of gaming experience performed an n-back working memory task with vowels, with the sensory modality of the vowel stream switching between audition and vision at random intervals. We studied the relationship between self-reported daily gaming activity, working memory (n-back) task performance and related brain activity measured using functional magnetic resonance imaging (fMRI). The results revealed that the extent of daily gaming activity was related to enhancements in both performance accuracy and speed during the most demanding (2-back) level of the working memory task. This improved working memory performance was accompanied by enhanced recruitment of a fronto-parietal cortical network, especially the dorsolateral prefrontal cortex. In contrast, during the less demanding (1-back) level of the task, gaming was associated with decreased activity in the same cortical regions. Our results suggest that a greater degree of daily gaming experience is associated with better working memory functioning and task difficulty-dependent modulation in fronto-parietal brain activity already in adolescence and even when non-expert gamers are studied. The direction of causality within this association cannot be inferred with certainty due to the correlational nature of the current study. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Device-level and module-level three-dimensional integrated circuits created using oblique processing

    NASA Astrophysics Data System (ADS)

    Burckel, D. Bruce

    2016-07-01

    This paper demonstrates that another class of three-dimensional integrated circuits (3-D-ICs) exists, distinct from through-silicon-via-centric and monolithic 3-D-ICs. Furthermore, it is possible to create devices that are 3-D "at the device level" (i.e., with active channels oriented in each of the three coordinate axes), by performing standard CMOS fabrication operations at an angle with respect to the wafer surface into high aspect ratio silicon substrates using membrane projection lithography (MPL). MPL requires only minimal fixturing changes to standard CMOS equipment, and no change to current state-of-the-art lithography. Eliminating the constraint of two-dimensional planar device architecture enables a wide range of interconnect topologies which could help reduce interconnect resistance/capacitance, and potentially improve performance.

  2. Individual differences in dopamine level modulate the ego depletion effect.

    PubMed

    Dang, Junhua; Xiao, Shanshan; Liu, Ying; Jiang, Yumeng; Mao, Lihua

    2016-01-01

    Initial exertion of self-control impairs subsequent self-regulatory performance, which is referred to as the ego depletion effect. The current study examined how individual differences in dopamine level, as indexed by eye blink rate (EBR), would moderate ego depletion. An inverted-U-shaped relationship between EBR and subsequent self-regulatory performance was found when participants initially engaged in self-control but such relationship was absent in the control condition where there was no initial exertion, suggesting individuals with a medium dopamine level may be protected from the typical ego depletion effect. These findings are consistent with a cognitive explanation which considers ego depletion as a phenomenon similar to "switch costs" that would be neutralized by factors promoting flexible switching. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Rectenna array measurement results. [Satellite power transmission and reception

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining are demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array are demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  4. Development of the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) Process for Cesium Removal from High-Level Tank Waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moyer, Bruce A; Bonnesen, Peter V; Delmau, Laetitia Helene

    2011-01-01

    This paper describes the chemical performance of the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process in its current state of development for removal of cesium from the alkaline high-level tank wastes at the Savannah River Site (SRS) in the US Department of Energy (USDOE) complex. Overall, motivation for seeking a major enhancement in performance for the currently deployed CSSX process stems from needs for accelerating the cleanup schedule and reducing the cost of salt-waste disposition. The primary target of the NG-CSSX development campaign in the past year has been to formulate a solvent system and to design a corresponding flowsheet thatmore » boosts the performance of the SRS Modular CSSX Unit (MCU) from a current minimum decontamination factor of 12 to 40,000. The chemical approach entails use of a more soluble calixarene-crown ether, called MaxCalix, allowing the attainment of much higher cesium distribution ratios (DCs) on extraction. Concurrently decreasing the Cs-7SB modifier concentration is anticipated to promote better hydraulics. A new stripping chemistry has been devised using a vitrification-friendly aqueous boric acid strip solution and a guanidine suppressor in the solvent, resulting in sharply decreased DCs on stripping. Results are reported herein on solvent phase behavior and batch Cs distribution for waste simulants and real waste together with a preliminary flowsheet applicable for implementation in the MCU. The new solvent will enable MCU to process a much wider range of salt feeds and thereby extend its service lifetime beyond its design life of three years. Other potential benefits of NG-CSSX include increased throughput of the SRS Salt Waste Processing Facility (SWPF), currently under construction, and an alternative modular near-tank application at Hanford.« less

  5. Indirect effects of elevated body mass index on memory performance through altered cerebral metabolite concentrations.

    PubMed

    Gonzales, Mitzi M; Tarumi, Takashi; Eagan, Danielle E; Tanaka, Hirofumi; Vaghasia, Miral; Haley, Andreana P

    2012-09-01

    Elevated body mass index (BMI) at midlife is associated with increased risk of cognitive decline in later life. The goal of the current study was to assess mechanisms of early brain vulnerability by examining if higher BMI at midlife affects current cognitive performance through alterations in cerebral neurochemistry. Fifty-five participants, aged 40 to 60 years, underwent neuropsychological testing, health screen, and proton magnetic resonance spectroscopy examining N-acetylaspartate, creatine (Cr), myo-inositol (mI), choline, and glutamate concentrations in occipitoparietal gray matter. Concentrations of N-acetylaspartate, choline, mI, and glutamate were calculated as a ratio over Cr and examined in relation to BMI using multivariate regression analyses. Structural equation modeling was used to determine if BMI had an indirect effect on cognition through cerebral metabolite levels. Higher BMI was associated with elevations in mI/Cr (F(5,45) = 3.843, p = .006, β = 0.444, p = .002), independent of age, sex, fasting glucose levels, and systolic blood pressure. Moreover, a χ(2) difference test of the direct and indirect structural equation models revealed that BMI had an indirect effect on global cognitive performance (Δχ(2) = 19.939, df = 2, p < .001). Subsequent follow-up analyses revealed that this effect was specific to memory (Δχ(2) = 22.027, df = 2, p < .001). Higher BMI was associated with elevations in mI/Cr concentrations in the occipitoparietal gray matter and indirectly related to poorer memory performance through mI/Cr levels, potentially implicating plasma hypertonicity and neuroinflammation as mechanisms underlying obesity-related brain vulnerability.

  6. Power Electronics Development for the SPT-100 Thruster

    NASA Technical Reports Server (NTRS)

    Hamley, John A.; Hill, Gerald M.; Sankovic, John M.

    1994-01-01

    Russian electric propulsion technologies have recently become available on the world market. Of significant interest is the Stationary Plasma Thruster (SPT) which has a significant flight heritage in the former Soviet space program. The SPT has performance levels of up to 1600 seconds of specific impulse at a thrust efficiency of 0.50. Studies have shown that this level of performance is well suited for stationkeeping applications, and the SPT-100, with a 1.35 kW input power level, is presently being evaluated for use on Western commercial satellites. Under a program sponsored by the Innovative Science and Technology Division of the Ballistic Missile Defense Organization, a team of U.S. electric propulsion specialists observed the operation of the SPT-100 in Russia. Under this same program, power electronics were developed to operate the SPT-100 to characterize thruster performance and operation in the U.S. The power electronics consisted of a discharge, cathode heater, and pulse igniter power supplies to operate the thruster with manual flow control. A Russian designed matching network was incorporated in the discharge supply to ensure proper operation with the thruster. The cathode heater power supply and igniter were derived from ongoing development projects. No attempts were made to augment thruster electromagnet current in this effort. The power electronics successfully started and operated the SPT-100 thruster in performance tests at NASA Lewis, with minimal oscillations in the discharge current. The efficiency of the main discharge supply was measured at 0.92, and straightforward modifications were identified which could increase the efficiency to 0.94.

  7. Superconducting power transmission system development. Cable insulation development

    NASA Astrophysics Data System (ADS)

    1983-09-01

    The development of an underground superconducting power transmission system which is economical and technically attractive to the utility industry is discussed. Suitable superconductors and dielectric insulation were developed. Cables several hundred feet long are tested under realistic conditions. Three operating runs of about 2 weeks duration each were accomplished. The 60 Hz steady state performance of the cables under rated conditions was explored. Over voltage endurance tests and emergency level current tests were performed.

  8. Industrial Energy Training and Certification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glatt, Sandy; Cox, Daryl; Nimbalkar, Sachin U.

    Compressed air systems, ammonia refrigeration systems, chilled water systems, steam systems, process heating systems, combined heat and power systems, pump systems and fan systems are major industrial energy systems commonly found in manufacturing facilities. Efficiency of these systems contributes significantly to whole facilities' energy performance. On the national, even international level, well-structured training and highly recognized certification programs help develop a highly-skilled and qualified workforce to maintain and improve facilities' energy performance, particularly as technologies within these systems become more advanced. The purpose of this paper is to review currently available training and certification programs focusing on these systems andmore » to identify the gap between market's needs and currently available programs. Three major conclusions are: first, most training programs focus on operations, maintenance, safety and design although some briefly touch the energy performance aspect; second, except CRES by RETA and PSA Certificate and PSAP Master Certification by HI, no other certifications had been found emphasizing on knowledge and skills for improving and maintaining these systems' energy performance; third, developing energy efficiency focused training and ANSI accredited certification programs on these energy systems will fill the gap between market's needs and currently available programs.« less

  9. Industrial Energy Training and Certification

    DOE PAGES

    Glatt, Sandy; Cox, Daryl; Nimbalkar, Sachin U.; ...

    2017-11-01

    Compressed air systems, ammonia refrigeration systems, chilled water systems, steam systems, process heating systems, combined heat and power systems, pump systems and fan systems are major industrial energy systems commonly found in manufacturing facilities. Efficiency of these systems contributes significantly to whole facilities' energy performance. On the national, even international level, well-structured training and highly recognized certification programs help develop a highly-skilled and qualified workforce to maintain and improve facilities' energy performance, particularly as technologies within these systems become more advanced. The purpose of this paper is to review currently available training and certification programs focusing on these systems andmore » to identify the gap between market's needs and currently available programs. Three major conclusions are: first, most training programs focus on operations, maintenance, safety and design although some briefly touch the energy performance aspect; second, except CRES by RETA and PSA Certificate and PSAP Master Certification by HI, no other certifications had been found emphasizing on knowledge and skills for improving and maintaining these systems' energy performance; third, developing energy efficiency focused training and ANSI accredited certification programs on these energy systems will fill the gap between market's needs and currently available programs.« less

  10. Performance evaluation of the Russian SPT-100 thruster at NASA LeRC

    NASA Technical Reports Server (NTRS)

    Sankovic, John M.; Hamley, John A.; Haag, Thomas W.

    1994-01-01

    Performance measurements of a Russian flight-model SPT-100 thruster were obtained as part of a comprehensive program to evaluate engineering issues pertinent to integration with Western spacecraft. Power processing was provided by a US Government developed laboratory power conditioner. When received the thruster had been subjected to only a few hours of acceptance testing by the manufacturer. Accumulated operating time during this study totalled 148 h and included operation of both cathodes. Cathode flow fraction was controlled both manually and using the flow splitter contained within the supplied xenon flow controller. Data were obtained at current levels ranging from 3 A to 5 A and thruster voltages ranging from 200 V to 300 V. Testing centered on the design power of 1.35 kW with a discharge current of 4.5 A. The effects of facility pressure on thruster operation were examined by varying the pressure via injection of xenon into the vacuum chamber. The facility pressure had a significant effect on thruster performance and stability at the conditions tested. Periods of current instabilities were noted throughout the testing period and became more frequent as testing progressed. Performance during periods of stability agreed with previous data obtained in Russian laboratories.

  11. The effects of deep level traps on the electrical properties of semi-insulating CdZnTe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zha, Gangqiang; Yang, Jian; Xu, Lingyan

    2014-01-28

    Deep level traps have considerable effects on the electrical properties and radiation detection performance of high resistivity CdZnTe. A deep-trap model for high resistivity CdZnTe was proposed in this paper. The high resistivity mechanism and the electrical properties were analyzed based on this model. High resistivity CdZnTe with high trap ionization energy E{sub t} can withstand high bias voltages. The leakage current is dependent on both the deep traps and the shallow impurities. The performance of a CdZnTe radiation detector will deteriorate at low temperatures, and the way in which sub-bandgap light excitation could improve the low temperature performance canmore » be explained using the deep trap model.« less

  12. Study of the cost/benefit tradeoffs for reducing the energy consumption of the commercial air transportation system

    NASA Technical Reports Server (NTRS)

    Hopkins, J. P.

    1976-01-01

    Practical means were assessed for achieving reduced fuel consumption in commercial air transportation. Five areas were investigated: current aircraft types, revised operational procedures, modifications to current aircraft, derivatives of current aircraft and new near-term fuel conservative aircraft. As part of a multiparticipant coordinated effort, detailed performance and operating cost data in each of these areas were supplied to the contractor responsible for the overall analysis of the cost/benefit tradeoffs for reducing the energy consumption of the domestic commercial air transportation system. A follow-on study was performed to assess the potential of an advanced turboprop transport aircraft concept. To provide a valid basis for comparison, an equivalent turbofan transport aircraft concept incorporating equal technology levels was also derived. The aircraft as compared on the basis of weight, size, fuel utilization, operational characteristics and costs.

  13. Effects of DC bias on magnetic performance of high grades grain-oriented silicon steels

    NASA Astrophysics Data System (ADS)

    Ma, Guang; Cheng, Ling; Lu, Licheng; Yang, Fuyao; Chen, Xin; Zhu, Chengzhi

    2017-03-01

    When high voltage direct current (HVDC) transmission adopting mono-polar ground return operation mode or unbalanced bipolar operation mode, the invasion of DC current into neutral point of alternating current (AC) transformer will cause core saturation, temperature increasing, and vibration acceleration. Based on the MPG-200D soft magnetic measurement system, the influence of DC bias on magnetic performance of 0.23 mm and 0.27 mm series (P1.7=0.70-1.05 W/kg, B8>1.89 T) grain-oriented (GO) silicon steels under condition of AC / DC hybrid excitation were systematically realized in this paper. For the high magnetic induction GO steels (core losses are the same), greater thickness can lead to stronger ability of resisting DC bias, and the reasons for it were analyzed. Finally, the magnetostriction and A-weighted magnetostriction velocity level of GO steel under DC biased magnetization were researched.

  14. State of Adult Trainee Inflammatory Bowel Disease Education in the United States: A National Survey.

    PubMed

    Cohen, Benjamin L; Ha, Christina; Ananthakrishnan, Ashwin N; Rieder, Florian; Bewtra, Meenakshi

    2016-07-01

    The fundamentals of inflammatory bowel disease (IBD) education begin during gastroenterology fellowship training. We performed a survey of gastroenterology fellowship program directors (PDs) and trainees with the aim to further examine the current state of IBD training in the United States. A 15-question PD survey and 19-question trainee survey was performed using an online platform. Surveys were completed by 43/161 (27%) PDs and 160 trainees. All trainee years were equally represented. A significant proportion of trainees was unsure or believed that their inpatient (32%) or outpatient (43%) training was inadequate. Only 28% of trainees were satisfied with their current level of IBD exposure during training. Fewer than half the trainees reported comfort in the management of pouch or stoma issues, pregnant patients with IBD, or postoperative management. The proportion of PDs viewing a competency as essential for trainee education strongly correlated with trainee comfort in that area (Pearson's rho = 0.793; P < 0.01). In multivariate logistic regression, monthly IBD didactics was the only variable independently associated with satisfaction with the current level of training (odds ratio, 4.1 95% CI, 1.9-9.0). Over one-third of participating gastroenterology trainees did not feel "confident" or "mostly comfortable" with their level of IBD training, with varying comfort regarding different competencies in IBD management. These findings suggest that specific areas of IBD training may require additional focus during training and can provide the basis for the development of an IBD core competency curriculum.

  15. Experimental Studies of the Effect of Intent Information on Cockpit Traffic Displays

    NASA Technical Reports Server (NTRS)

    Barhydt, Richard; Hansman, R. John

    1997-01-01

    Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: Position, Rate, Commanded State, and FMS (Flight Management System)-Path. The current TCAS (traffic collision avoidance systems) Display, which shows altitude rate in addition to current position and altitude, was used as a baseline and represents the lowest level of intent. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An initial experiment was run on the MIT (Massachusetts Institute of Technology) Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.

  16. Effects of Transcranial Direct Current Stimulation on Neural Networks in Young and Older Adults

    PubMed

    Martin, Andrew K; Meinzer, Marcus; Lindenberg, Robert; Sieg, Mira M; Nachtigall, Laura; Flöel, Agnes

    2017-11-01

    Transcranial direct current stimulation (tDCS) may be a viable tool to improve motor and cognitive function in advanced age. However, although a number of studies have demonstrated improved cognitive performance in older adults, other studies have failed to show restorative effects. The neural effects of beneficial stimulation response in both age groups is lacking. In the current study, tDCS was administered during simultaneous fMRI in 42 healthy young and older participants. Semantic word generation and motor speech baseline tasks were used to investigate behavioral and neural effects of uni- and bihemispheric motor cortex tDCS in a three-way, crossover, sham tDCS controlled design. Independent components analysis assessed differences in task-related activity between the two age groups and tDCS effects at the network level. We also explored whether laterality of language network organization was effected by tDCS. Behaviorally, both active tDCS conditions significantly improved semantic word retrieval performance in young and older adults and were comparable between groups and stimulation conditions. Network-level tDCS effects were identified in the ventral and dorsal anterior cingulate networks in the combined sample during semantic fluency and motor speech tasks. In addition, a shift toward enhanced left laterality was identified in the older adults for both active stimulation conditions. Thus, tDCS results in common network-level modulations and behavioral improvements for both age groups, with an additional effect of increasing left laterality in older adults.

  17. The role of incline, performance level, and gender on the gross mechanical efficiency of roller ski skating

    PubMed Central

    Sandbakk, Øyvind; Hegge, Ann Magdalen; Ettema, Gertjan

    2013-01-01

    The ability to efficiently utilize metabolic energy to produce work is a key factor for endurance performance. The present study investigated the effects of incline, performance level, and gender on the gross mechanical efficiency during roller ski skating. Thirty-one male and nineteen female elite cross-country skiers performed a 5-min submaximal session at approximately 75% of VO2peak on a 5% inclined treadmill using the G3 skating technique. Thereafter, a 5-min session on a 12% incline using the G2 skating technique was performed at a similar work rate. Gross efficiency was calculated as the external work rate against rolling friction and gravity divided by the metabolic rate using gas exchange. Performance level was determined by the amount of skating FIS points [the Federation of International Skiing (FIS) approved scoring system for ski racing] where fewer points indicate a higher performance level. Strong significant correlations between work rate and metabolic rate within both inclines and gender were revealed (r = −0.89 to 0.98 and P < 0.05 in all cases). Gross efficiency was higher at the steeper incline, both for men (17.1 ± 0.4 vs. 15.8 ± 0.5%, P < 0.05) and women (16.9 ± 0.5 vs. 15.7 ± 0.4%, P < 0.05), but without any gender differences being apparent. Significant correlations between gross efficiency and performance level were found for both inclines and genders (r = −0.65 to 0.81 and P < 0.05 in all cases). The current study demonstrated that cross-country skiers of both genders used less metabolic energy to perform the same amount of work at steeper inclines, and that the better ranked elite male and female skiers skied more efficiently. PMID:24155722

  18. When we test, do we stress? Impact of the testing environment on cortisol secretion and memory performance in older adults.

    PubMed

    Sindi, Shireen; Fiocco, Alexandra J; Juster, Robert-Paul; Pruessner, Jens; Lupien, Sonia J

    2013-08-01

    The majority of studies find that older adults have worse memory performance than young adults. However, contextual features in the testing environment may be perceived as stressful by older adults, increasing their stress hormone levels. Given the evidence that older adults are highly sensitive to the effects of stress hormones (cortisol) on memory performance, it is postulated that a stressful testing environment in older adults can lead to an acute stress response and to memory impairments. The current study compared salivary cortisol levels and memory performance in young and older adults tested in environments manipulated to be stressful (unfavourable condition) or not stressful (favourable condition) for each age group. 28 young adults and 32 older adults were tested in two testing conditions: (1) a condition favouring young adults (constructed to be less stressful for young adults), and (2) a condition favouring older adults (constructed to be less stressful for older adults). The main outcome measure was salivary cortisol levels. Additionally, immediate and delayed memory performances were assessed during each condition. In older adults only, we found significantly high cortisol levels and low memory performance in the condition favouring young adults. In contrast, cortisol levels were lower and memory performance was better when older adults were tested in conditions favouring them. There was no effect of testing condition in young adults. The results demonstrate that older adults' memory performance is highly sensitive to the testing environment. These findings have important implications for both research and clinical settings in which older adults are tested for memory performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. The role of incline, performance level, and gender on the gross mechanical efficiency of roller ski skating.

    PubMed

    Sandbakk, Oyvind; Hegge, Ann Magdalen; Ettema, Gertjan

    2013-01-01

    The ability to efficiently utilize metabolic energy to produce work is a key factor for endurance performance. The present study investigated the effects of incline, performance level, and gender on the gross mechanical efficiency during roller ski skating. Thirty-one male and nineteen female elite cross-country skiers performed a 5-min submaximal session at approximately 75% of VO2peak on a 5% inclined treadmill using the G3 skating technique. Thereafter, a 5-min session on a 12% incline using the G2 skating technique was performed at a similar work rate. Gross efficiency was calculated as the external work rate against rolling friction and gravity divided by the metabolic rate using gas exchange. Performance level was determined by the amount of skating FIS points [the Federation of International Skiing (FIS) approved scoring system for ski racing] where fewer points indicate a higher performance level. Strong significant correlations between work rate and metabolic rate within both inclines and gender were revealed (r = -0.89 to 0.98 and P < 0.05 in all cases). Gross efficiency was higher at the steeper incline, both for men (17.1 ± 0.4 vs. 15.8 ± 0.5%, P < 0.05) and women (16.9 ± 0.5 vs. 15.7 ± 0.4%, P < 0.05), but without any gender differences being apparent. Significant correlations between gross efficiency and performance level were found for both inclines and genders (r = -0.65 to 0.81 and P < 0.05 in all cases). The current study demonstrated that cross-country skiers of both genders used less metabolic energy to perform the same amount of work at steeper inclines, and that the better ranked elite male and female skiers skied more efficiently.

  20. User acceptance of intelligent avionics: A study of automatic-aided target recognition

    NASA Technical Reports Server (NTRS)

    Becker, Curtis A.; Hayes, Brian C.; Gorman, Patrick C.

    1991-01-01

    User acceptance of new support systems typically was evaluated after the systems were specified, designed, and built. The current study attempts to assess user acceptance of an Automatic-Aided Target Recognition (ATR) system using an emulation of such a proposed system. The detection accuracy and false alarm level of the ATR system were varied systematically, and subjects rated the tactical value of systems exhibiting different performance levels. Both detection accuracy and false alarm level affected the subjects' ratings. The data from two experiments suggest a cut-off point in ATR performance below which the subjects saw little tactical value in the system. An ATR system seems to have obvious tactical value only if it functions at a correct detection rate of 0.7 or better with a false alarm level of 0.167 false alarms per square degree or fewer.

  1. The impact of attaining the Welsh Baccalaureate Advanced Diploma on academic performance in bioscience higher education

    NASA Astrophysics Data System (ADS)

    Yhnell, Emma; Wood, Heather; Baker, Mathew; Amici-Dargan, Sheila; Taylor, Chris; Randerson, Peter; Shore, Andrew

    2016-01-01

    Since the introduction of the Welsh Baccalaureate Advanced Diploma Qualification (WBQ) in 2003, an increasing number of students are applying to higher education institutions (HEIs) with this qualification. The advanced-level WBQ is regarded as equivalent to one General Certificate of Education A-Level (GCE A-Level). This study assesses the impact of attaining the WBQ in addition to three GCE A-Levels on overall university degree performance in comparison to attaining four GCE A-Levels, in three cohorts of undergraduate students (Year 1 = 318, Year 2 = 280, Year 3 = 236) studying Biosciences from 2005 to 2011 at a UK HEI. Binary logistic regression was used to compare the academic attainment of students who had achieved four GCE A-Levels to those who had achieved three GCE A-Levels in addition to the WBQ. Comparisons were also made between students who had achieved three GCE A-Levels and those who had achieved three GCE A-Levels in addition to the WBQ. The results suggest that students who achieved the WBQ qualification in its current form, in addition to three GCE A-Levels, performed less well academically in undergraduate studies than those who achieved four GCE A-Levels. Furthermore, this effect was still present when the balance between coursework and examination was considered, and when students who had achieved the WBQ in addition to three GCE A-Levels were compared to students who had achieved three GCE A-Levels.

  2. Small signal amplifiers and converters for millimeter wave Satcom systems

    NASA Technical Reports Server (NTRS)

    Okean, H. C.

    1979-01-01

    This paper describes the current state of the art and the various design tradeoffs encompassing the variety of small signal active circuit 'building blocks' deployed in millimeter wave Satcom receivers and transmitters. Included in this catagory are such low noise receiver components as parametric and FET amplifiers and low loss mixer downconverters as well as low level transmitter driver components such as resistive and varactor upconverters. Current and projected state of the art performance data will be presented along with specific examples of operating hardware.

  3. Multi-Model Validation of Currents in the Chesapeake Bay Region in June 2010

    DTIC Science & Technology

    2012-01-01

    host “ DaVinci ” at the Naval Oceanographic Office (NAVOCEANO). The same model configuration also took approximately 1 hr of wall clock time for a 72-hr...comparable to the performance Navy DSRC host DaVinci . Products of water level and horizontal current maps as well as station time series, identical to...DSRC host DaVinci and required approximately 5 hrs of wall-clock time for 72-hr forecasts, including data Figure 10. The Chesapeake Bay Delft3D

  4. Foundations for a syntatic pattern recognition system for genomic DNA sequences. [Annual] report, 1 December 1991--31 March 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Searles, D.B.

    1993-03-01

    The goal of the proposed work is the creation of a software system that will perform sophisticated pattern recognition and related functions at a level of abstraction and with expressive power beyond current general-purpose pattern-matching systems for biological sequences; and with a more uniform language, environment, and graphical user interface, and with greater flexibility, extensibility, embeddability, and ability to incorporate other algorithms, than current special-purpose analytic software.

  5. Sleep, performance, and plasma levels in chronic insomniacs during 14-day use of flurazepam and midazolam: an introduction.

    PubMed

    Johnson, L C; Chernik, D A; Sateia, M J

    1990-08-01

    A review of the published literature reveals many unanswered questions regarding the effects of sedative-hypnotics on sleep, performance, and mood. The relationship between plasma half-life and hypnotic efficacy is also not clear. A randomized, double-blind, parallel-groups, multicenter study was designed to examine sleep, performance, and mood in patients with insomnia. A large, heterogeneous sample of patients with a history of benzodiazepine use for chronic insomnia was chosen to reflect the adult population for which sedative-hypnotics are often prescribed and to ensure statistical reliability. Although the major focus of the current study was on the effects of two benzodiazepine hypnotics on performance, this study also provided information on the following important issues: (1) effect of dose level; (2) short-versus long-term administration; and (3) significance of plasma half-life as it relates to hypnotic efficacy.

  6. A new thermally driven refrigeration system with environmental benefits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garris, C.A. Jr.; Hong, W.J.; Mavriplis, C.

    1998-07-01

    The pressure-exchange ejector offers the possibility of attaining a breakthrough in the level of performance of ejectors by means of utilizing non-dissipative non-steady flow mechanisms. Yet, the device retains much of the mechanical simplicity of conventional steady-flow ejectors. If such a substantial improvement in performance is demonstrated, its application to ejector refrigeration will be very important. Such a development would provide significant benefits for the environment in terms of both CFC usage reduction and greenhouse gas reduction. The current paper will discuss in detail the concept of pressure-exchange ejector refrigeration, compare it with existing technologies, and discuss the potential impactmore » that might be derived if certain levels of ejector performance can be achieved. Since the limiting issue on the system performance is in the fluid dynamics of non-steady flow induction, research issues and recent progress will be discussed.« less

  7. Test techniques for determining laser ranging system performance

    NASA Technical Reports Server (NTRS)

    Zagwodzki, T. W.

    1981-01-01

    Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.

  8. Adaptive Optics Communications Performance Analysis

    NASA Technical Reports Server (NTRS)

    Srinivasan, M.; Vilnrotter, V.; Troy, M.; Wilson, K.

    2004-01-01

    The performance improvement obtained through the use of adaptive optics for deep-space communications in the presence of atmospheric turbulence is analyzed. Using simulated focal-plane signal-intensity distributions, uncoded pulse-position modulation (PPM) bit-error probabilities are calculated assuming the use of an adaptive focal-plane detector array as well as an adaptively sized single detector. It is demonstrated that current practical adaptive optics systems can yield performance gains over an uncompensated system ranging from approximately 1 dB to 6 dB depending upon the PPM order and background radiation level.

  9. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment.

    PubMed

    Allen, Peter M; Latham, Keziah; Mann, David L; Ravensbergen, Rianne H J C; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual's average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving 'expected' or 'below expected' shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An impairment to CS could impact performance in the sport and might be considered in determining eligibility to take part in VI competition.

  10. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment

    PubMed Central

    Allen, Peter M.; Latham, Keziah; Mann, David L.; Ravensbergen, Rianne H. J. C.; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual’s average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving ‘expected’ or ‘below expected’ shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An impairment to CS could impact performance in the sport and might be considered in determining eligibility to take part in VI competition. PMID:27877150

  11. An assessment of the performance and quality control procedures of PACS workstation monitors used in Irish radiology departments

    NASA Astrophysics Data System (ADS)

    Wade, Cherrie; Brennan, Patrick C.; Mc Entee, Mark F.

    2005-04-01

    Diagnostic efficacy in soft-copy reporting relies heavily on the quality of workstation monitors and an investigation performed in 2002 demonstrated that CRT monitors in Dublin imaging departments were not operating at optimal levels. The current work examines the performance of CRTs being used in Dublin and other parts of Ireland to establish if problems reported in the earlier work have been rectified. All hospitals performing soft-copy reporting for general radiology using CRTs were included in the work. Examination of ambient lighting, calibration of monitors and analysis of CRT performance using the SMPTE test pattern and a selection of the AAPM test images was performed. Maximum luminance, spatial uniformity of luminance, temporal luminance stability, gamma, geometry, sharpness, veiling glare and spatial resolution of each monitor was evaluated. Ambient lighting in all reporting areas was within recommended levels. All the monitors were calibrated appropriately and were performing at acceptable levels for maximum luminance and temporal stability and only one of the thirty-three investigated failed to reach the standard for spatial uniformity. In contrast a number of the CRTs investigated showed poor adherence to acceptable levels for geometrical distortions, veiling glare and spatial resolution all of which are important influencers of image quality. Gamma values also appeared to be low for a number of monitors but this interpretation is provisional and subject to the establishment of ratified guideline values. The results demonstrate that although some improvement on the previous situation is evident, greater adherence to acceptable levels is required for certain parameters.

  12. PTSD, Acute Stress, Performance and Decision-Making in Emergency Service Workers.

    PubMed

    Regehr, Cheryl; LeBlanc, Vicki R

    2017-06-01

    Despite research identifying high levels of stress and traumatic stress symptoms among those in the emergency services, the impact of these symptoms on performance and hence public safety remains uncertain. This review paper discusses a program of research that has examined the effects of prior critical incident exposure, acute stress, and current post-traumatic symptoms on the performance and decision-making during an acutely stressful event among police officers, police communicators, paramedics and child protection workers. Four studies, using simulation methods involving video simulators, human-patient simulators, and/or standardized patients, examined the performance of emergency workers in typical workplace situations related to their individual profession. Results varied according to level of acuity of stress and the nature of performance and decision-making. There was no evidence that PTSD had a direct impact on global performance on tasks for which emergency responders are highly trained. However, PTSD was associated with assessment of risk in situations that required professional judgement. Further, individuals experiencing PTSD symptoms reported higher levels of acute stress when faced with high acuity situations. Acute stress in these studies was associated with performance deficits on complex cognitive tasks, verbal memory impairment and heightened assessment of risk. © 2017 American Academy of Psychiatry and the Law.

  13. Daily micro-breaks and job performance: General work engagement as a cross-level moderator.

    PubMed

    Kim, Sooyeol; Park, YoungAh; Headrick, Lucille

    2018-03-29

    Despite the growing research on work recovery and its well-being outcomes, surprisingly little attention has been paid to at-work recovery and its job performance outcomes. The current study extends the work recovery literature by examining day-level relationships between prototypical microbreaks and job performance as mediated by state positive affect. Furthermore, general work engagement is tested as a cross-level moderator weakening the indirect effects of microbreaks on job performance via positive affect. Using multisource experience sampling method, the authors collected two daily surveys from 71 call center employees and obtained objective records of daily sales performance for two consecutive weeks (n = 632). Multilevel path analysis results showed that relaxation, socialization, and cognitive microbreaks were related to increased positive affect at work which, in turn, predicted greater sales performance. However, breaks for nutrition-intake (having snacks and drinks) did not show significant effects. Importantly, microbreaks had significant indirect effects on job performance via positive affect only for workers who had lower general work engagement, whereas the indirect effects did not exist for workers who had higher general work engagement. Furthermore, Bayesian multilevel analyses confirmed the results. Theoretical and practical implications, limitations, and future research directions are discussed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. Benefits Derived From Laser Ranging Measurements for Orbit Determination of the GPS Satellite Orbit

    NASA Technical Reports Server (NTRS)

    Welch, Bryan W.

    2007-01-01

    While navigation systems for the determination of the orbit of the Global Position System (GPS) have proven to be very effective, the current research is examining methods to lower the error in the GPS satellite ephemerides below their current level. Two GPS satellites that are currently in orbit carry retro-reflectors onboard. One notion to reduce the error in the satellite ephemerides is to utilize the retro-reflectors via laser ranging measurements taken from multiple Earth ground stations. Analysis has been performed to determine the level of reduction in the semi-major axis covariance of the GPS satellites, when laser ranging measurements are supplemented to the radiometric station keeping, which the satellites undergo. Six ground tracking systems are studied to estimate the performance of the satellite. The first system is the baseline current system approach which provides pseudo-range and integrated Doppler measurements from six ground stations. The remaining five ground tracking systems utilize all measurements from the current system and laser ranging measurements from the additional ground stations utilized within those systems. Station locations for the additional ground sites were taken from a listing of laser ranging ground stations from the International Laser Ranging Service. Results show reductions in state covariance estimates when utilizing laser ranging measurements to solve for the satellite s position component of the state vector. Results also show dependency on the number of ground stations providing laser ranging measurements, orientation of the satellite to the ground stations, and the initial covariance of the satellite's state vector.

  15. Development activities on NIR large format MCT detectors for astrophysics and space science at CEA and SOFRADIR

    NASA Astrophysics Data System (ADS)

    Boulade, Olivier; Moreau, Vincent; Mulet, Patrick; Gravrand, Olivier; Cervera, Cyril; Zanatta, Jean-Paul; Castelein, Pierre; Guellec, Fabrice; Fièque, Bruno; Chorier, Philippe; Roumegoux, Julien

    2016-07-01

    CEA and SOFRADIR have been manufacturing and characterizing near infrared detectors in the frame of ESA's near infrared large format sensor array roadmap to develop a 2Kx2K large format low flux low noise device for space applications such as astrophysics. These detectors use HgCdTe as the absorbing material and p/n diode technology. The technological developments (photovoltaic technology, readout circuit, ...) are shared between CEA/LETI and SOFRADIR, both in Grenoble, while most of the performances are evaluated at CEA/IRFU in Saclay where a dedicated test facility has been developed, in particular to measure very low dark currents. The paper will present the current status of these developments at the end of ESA's NIRLFSA phase 2. The performances of the latest batch of devices meet or are very close to all the requirements (quantum efficiency, dark current, cross talk, readout noise, ...) even though a glow induced by the ROIC prevents the accurate measurement of the dark current. The current devices are fairly small, 640x512 15μm pixels, and the next phase of activity will target the development of a full size 2Kx2K detector. From the design and development, to the manufacturing and finally the testing, that type of detector requests a high level of mastering. An appropriate manufacturing and process chain compatible with such a size is needed at industrial level and results obtained with CEA technology coupled with Sofradir industrial experience and work on large dimension detector allow French actors to be confident to address this type of future missions.

  16. Does a Speaking Task Affect Second Language Comprehensibility?

    ERIC Educational Resources Information Center

    Crowther, Dustin; Trofimovich, Pavel; Isaacs, Talia; Saito, Kazuya

    2015-01-01

    The current study investigated task effects on listener perception of second language (L2) comprehensibility (ease of understanding). Sixty university-level adult speakers of English from 4 first language (L1) backgrounds (Chinese, Romance, Hindi, Farsi), with 15 speakers per group, were recorded performing 2 tasks (IELTS long-turn speaking task…

  17. Apprehension and Effective Writing in the Principalship.

    ERIC Educational Resources Information Center

    Podsen, India J.

    1991-01-01

    A random sample of 305 principals was drawn from the membership roosters of 4 Principal Centers. Responses from 100 principals (33 percent) show that there is a relationship between writing apprehension level on performance of job writing skills. Advises school administrators to take courses in current written communication practices. (six…

  18. Evaluating the Outcomes of Advanced Neonatal Nurse Practitioner Programmes.

    ERIC Educational Resources Information Center

    Redshaw, Margaret; Hart, Bev; Harvey, Merryl; Harris, Anne

    The outcomes of advanced neonatal nurse practitioner (ANNP) programs in the United Kingdom were examined. The different programs of education currently available for nurses wishing to become ANNPs were compared, and the outcomes of ANNP programs, as demonstrated in the levels of performance of practitioners undertaking different programs, were…

  19. 40 CFR 63.9590 - What emission limitations must I meet?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) For each dry electrostatic precipitator applied to meet any particulate matter emission limit in Table... voltage and daily average secondary current for each field at or above the minimum levels established during the initial performance test. (4) For each wet electrostatic precipitator applied to meet any...

  20. 40 CFR 63.9590 - What emission limitations must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) For each dry electrostatic precipitator applied to meet any particulate matter emission limit in Table... voltage and daily average secondary current for each field at or above the minimum levels established during the initial performance test. (4) For each wet electrostatic precipitator applied to meet any...

  1. The Contradictions of Policy and Practice: Creativity in Higher Education

    ERIC Educational Resources Information Center

    MacLaren, Iain

    2012-01-01

    Whilst much of the rhetoric of current educational policy champions creativity and innovation, structural reforms and new management practices in higher education run counter to the known conditions under which creativity flourishes. As a review of recent literature suggests, surveillance, performativity, the end of tenure and rising levels of…

  2. Detection of CMOS bridging faults using minimal stuck-at fault test sets

    NASA Technical Reports Server (NTRS)

    Ijaz, Nabeel; Frenzel, James F.

    1993-01-01

    The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.

  3. Current Vocational Training in Latin America.

    ERIC Educational Resources Information Center

    Alexim, Joao Carlos

    Vocational training (VT) programs in Latin America prepare workers to perform middle-level occupations or jobs. VT in Latin America is characterized by the existence of solid and autonomous national institutes linked to the logic of economic production, funded through a payroll levy grant, counting on a tripartite board, and related to ministries…

  4. Aerobic Fitness and Intra-Individual Variability of Neurocognition in Preadolescent Children

    ERIC Educational Resources Information Center

    Moore, Robert Davis; Wu, Chien-Ting; Pontifex, Matthew B.; O'Leary, Kevin C.; Scudder, Mark R.; Raine, Lauren B.; Johnson, Christopher R.; Hillman, Charles H.

    2013-01-01

    This study examined behavioral and neuroelectric intra-individual variability (IIV) in preadolescent children during a task requiring variable amounts of cognitive control. The current study further examined whether IIV was moderated by aerobic fitness level. Participants performed a modified flanker task, comprised of congruent and incongruent…

  5. RtI in Math Class

    ERIC Educational Resources Information Center

    Gresham, Gina; Little, Mary

    2012-01-01

    One of the most difficult tasks that classroom teachers face is finding ways to reach all their students and match each student's level of mathematical readiness and performance to the skills they are required to teach. In classrooms and schools, current federal and state requirements have increased the emphasis on accountability for improved…

  6. Correlation of Understanding of Physics and Psychological Symptoms among High-School Students in Greece

    ERIC Educational Resources Information Center

    Aggeliki, Anagnostopoulou; Miltiades, Kyprianou; Antigoni-Elisavet, Rota; Evangelia, Pavlatou; Loizos, Zaphiris

    2017-01-01

    Depression may essentially influence cognitive function contributing to poor school performance. The present study undertakes to determine the existence and strength of correlation between depressive symptomatology and other mental conditions with the acquired level of understanding of Newtonian physics taught in schools. The current study…

  7. Altered performance of forest pests under atmospheres enriched by C02 and O3

    Treesearch

    Kevin E. Percy; Caroline S. Awmack; Richard L. Lindroth; Mark E. Kubiske; Brian J. Kopper; J. G. Isebrands; Kurt S. Pregitzer; George R. Hendrey; Richard E. Dickson; Donald R. Zak; Elina Oksanen; Jaak Sober; Richard Harrington; David F. Karnosky

    2002-01-01

    Human activity causes increasing background concentrations of the greenhouse gases C02 and O3. Increased levels of C02 can be found in all terrestrial ecosystems. Damaging O3 concentrations currently occur over 29% of the world's temperate and subpolar forests but are...

  8. 24-Hour Academic Libraries: Adjusting to Change

    ERIC Educational Resources Information Center

    Bowman, Adam C.

    2013-01-01

    The purpose of this study was to explore the adaptive measures that academic libraries perform when implementing and operating a 24-hour schedule. Five in-depth interviews were conducted with current managerial-level librarians at 24-hour academic libraries. The exploratory interviews revealed similar measures for security, budgeting, employee…

  9. Modification of polymer velvet cathode via metallic Mo coating for enhancement of high-current electron emission performances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Ying; Wang, Bing; Yi, Yong

    2013-09-15

    The effect of surface Mo coating on the high-current electron emission performances for polymer velvet cathode has been investigated in a diode with A-K gap of 11.5 cm by the combination of time-resolved electrical diagnostic and temporal pressure variation. Compared with uncoated polymer velvet cathode under the single-pulsed emission mode, the Mo-coated one shows lower outgassing levels (∼0.40 Pa L), slower cathode plasma expansion velocity (∼2.30 cm/μs), and higher emission stability as evidences by the change in cathode current, temporal pressure variation, and diode perveance. Moreover, after Mo coating, the emission consistency of the polymer velvet cathode between two adjacentmore » pulses is significantly improved in double-pulsed emission mode with ∼500 ns interval between two pulses, which further confirms the effectiveness of Mo coating for enhancement of electron emission performance of polymer velvet cathodes. These results should be of interest to the high-repetitive high-power microwave systems with cold cathodes.« less

  10. The 1.06 optical receiver. [avalanche photodiodes for laser range finders

    NASA Technical Reports Server (NTRS)

    Tomasetta, L. R.; Law, H. D.; Nakano, K.; Scholl, F. W.; Harris, J. S., Jr.

    1978-01-01

    High performance 1.06 micron m avalanche photodetectors (APDs), fabricated in the GaAlSb system, have high quantum efficiency (90 percent), high speed (risetime less than 60 ps) and low leakage currents (less than 50 na). The dark current represents more than an order of magnitude reduction compared to previously reported results. The high speed avalanche gain of these devices is between 20 and 50. The area uniformity is better than + or - 10 percent. GaAlAs APDs at 0.53 micron m have even faster speed, lower dark currents, and high speed gains of 100 to 200. Optical rangefinders based on measured APD performance parameters have far superior performance when compared to even ideal photomultiplier tubes in either a one color or two color rangefinder system. For a one color system, f factor of two lower time jitter can be achieved with identical transmitted power. The superiority of the APD based two color receiver is significant and exists in the entire range of desired time jitters (less than 100 ps) and received power levels.

  11. Collective hormonal profiles predict group performance.

    PubMed

    Akinola, Modupe; Page-Gould, Elizabeth; Mehta, Pranjal H; Lu, Jackson G

    2016-08-30

    Prior research has shown that an individual's hormonal profile can influence the individual's social standing within a group. We introduce a different construct-a collective hormonal profile-which describes a group's hormonal make-up. We test whether a group's collective hormonal profile is related to its performance. Analysis of 370 individuals randomly assigned to work in 74 groups of three to six individuals revealed that group-level concentrations of testosterone and cortisol interact to predict a group's standing across groups. Groups with a collective hormonal profile characterized by high testosterone and low cortisol exhibited the highest performance. These collective hormonal level results remained reliable when controlling for personality traits and group-level variability in hormones. These findings support the hypothesis that groups with a biological propensity toward status pursuit (high testosterone) coupled with reduced stress-axis activity (low cortisol) engage in profit-maximizing decision-making. The current work extends the dual-hormone hypothesis to the collective level and provides a neurobiological perspective on the factors that determine who rises to the top across, not just within, social hierarchies.

  12. Collective hormonal profiles predict group performance

    PubMed Central

    Akinola, Modupe; Page-Gould, Elizabeth; Mehta, Pranjal H.; Lu, Jackson G.

    2016-01-01

    Prior research has shown that an individual’s hormonal profile can influence the individual’s social standing within a group. We introduce a different construct—a collective hormonal profile—which describes a group’s hormonal make-up. We test whether a group’s collective hormonal profile is related to its performance. Analysis of 370 individuals randomly assigned to work in 74 groups of three to six individuals revealed that group-level concentrations of testosterone and cortisol interact to predict a group’s standing across groups. Groups with a collective hormonal profile characterized by high testosterone and low cortisol exhibited the highest performance. These collective hormonal level results remained reliable when controlling for personality traits and group-level variability in hormones. These findings support the hypothesis that groups with a biological propensity toward status pursuit (high testosterone) coupled with reduced stress-axis activity (low cortisol) engage in profit-maximizing decision-making. The current work extends the dual-hormone hypothesis to the collective level and provides a neurobiological perspective on the factors that determine who rises to the top across, not just within, social hierarchies. PMID:27528679

  13. Correlation analysis between the current fluctuation characteristics and the conductive filament morphology of HfO2-based memristor

    NASA Astrophysics Data System (ADS)

    Li, Yi; Yin, Kang-Sheng; Zhang, Mei-Yun; Cheng, Long; Lu, Ke; Long, Shi-Bing; Zhou, Yaxiong; Wang, Zhuorui; Xue, Kan-Hao; Liu, Ming; Miao, Xiang-Shui

    2017-11-01

    Memristors are attracting considerable interest for their prospective applications in nonvolatile memory, neuromorphic computing, and in-memory computing. However, the nature of resistance switching is still under debate, and current fluctuation in memristors is one of the critical concerns for stable performance. In this work, random telegraph noise (RTN) as the indication of current instabilities in distinct resistance states of the Pt/Ti/HfO2/W memristor is thoroughly investigated. Standard two-level digital-like RTN, multilevel current instabilities with non-correlation/correlation defects, and irreversible current transitions are observed and analyzed. The dependence of RTN on the resistance and read bias reveals that the current fluctuation depends strongly on the morphology and evolution of the conductive filament composed of oxygen vacancies. Our results link the current fluctuation behaviors to the evolution of the conductive filament and will guide continuous optimization of memristive devices.

  14. Country-level correlates of e-cigarette use in the European Union.

    PubMed

    La Torre, Giuseppe; Mipatrini, Daniele

    2016-03-01

    The aim of this study was to assess the relationship between the prevalence of e-cigarette use and country-level factors across 28 European countries. The study objectives were addressed in an ecological design in which both exposures and outcomes were measured at the country level. Data from the Eurobarometer Report, the Eurostat database and the WHO observatory were analyzed. Bivariate and multivariate analyses were performed considering the rates of current and ever smokers of e-cigarettes as dependent variables, and socio-economic factors, health status and policies against tobacco as independent variables. Both the rate of current smokers and ever smokers of e-cigarette were positively associated to the offer of help to quit tobacco use (P < 0.01; P = 0.04) and to the raise of taxes on tobacco (P = 0.01; P = 0.01). The warn on dangers of tobacco negatively correlated with the rate of e-cigarette current smokers. The rate of current e-cigarette smokers correlated with the rate of current smokers and with national Gross Domestic Product, while the rate of ever e-cigarette smokers did not correlate with any socio-economic factor. Our analysis suggests that both policy and non-policy factors are associated with the geographical variability seen in the prevalence of e-cigarette use. Policies against the consumption of conventional tobacco products may lead to an increase of e-cigarette smokers.

  15. GaAs VLSI technology and circuit elements for DSP

    NASA Astrophysics Data System (ADS)

    Mikkelson, James M.

    1990-10-01

    Recent progress in digital GaAs circuit performance and complexity is presented to demonstrate the current capabilities of GaAs components. High density GaAs process technology and circuit design techniques are described and critical issues for achieving favorable complexity speed power and cost tradeoffs are reviewed. Some DSP building blocks are described to provide examples of what types of DSP systems could be implemented with present GaAs technology. DIGITAL GaAs CIRCUIT CAPABILITIES In the past few years the capabilities of digital GaAs circuits have dramatically increased to the VLSI level. Major gains in circuit complexity and power-delay products have been achieved by the use of silicon-like process technologies and simple circuit topologies. The very high speed and low power consumption of digital GaAs VLSI circuits have made GaAs a desirable alternative to high performance silicon in hardware intensive high speed system applications. An example of the performance and integration complexity available with GaAs VLSI circuits is the 64x64 crosspoint switch shown in figure 1. This switch which is the most complex GaAs circuit currently available is designed on a 30 gate GaAs gate array. It operates at 200 MHz and dissipates only 8 watts of power. The reasons for increasing the level of integration of GaAs circuits are similar to the reasons for the continued increase of silicon circuit complexity. The market factors driving GaAs VLSI are system design methodology system cost power and reliability. System designers are hesitant or unwilling to go backwards to previous design techniques and lower levels of integration. A more highly integrated system in a lower performance technology can often approach the performance of a system in a higher performance technology at a lower level of integration. Higher levels of integration also lower the system component count which reduces the system cost size and power consumption while improving the system reliability. For large gate count circuits the power per gate must be minimized to prevent reliability and cooling problems. The technical factors which favor increasing GaAs circuit complexity are primarily related to reducing the speed and power penalties incurred when crossing chip boundaries. Because the internal GaAs chip logic levels are not compatible with standard silicon I/O levels input receivers and output drivers are needed to convert levels. These I/O circuits add significant delay to logic paths consume large amounts of power and use an appreciable portion of the die area. The effects of these I/O penalties can be reduced by increasing the ratio of core logic to I/O on a chip. DSP operations which have a large number of logic stages between the input and the output are ideal candidates to take advantage of the performance of GaAs digital circuits. Figure 2 is a schematic representation of the I/O penalties encountered when converting from ECL levels to GaAs

  16. Evaluating structural pattern recognition for handwritten math via primitive label graphs

    NASA Astrophysics Data System (ADS)

    Zanibbi, Richard; Mouchère, Harold; Viard-Gaudin, Christian

    2013-01-01

    Currently, structural pattern recognizer evaluations compare graphs of detected structure to target structures (i.e. ground truth) using recognition rates, recall and precision for object segmentation, classification and relationships. In document recognition, these target objects (e.g. symbols) are frequently comprised of multiple primitives (e.g. connected components, or strokes for online handwritten data), but current metrics do not characterize errors at the primitive level, from which object-level structure is obtained. Primitive label graphs are directed graphs defined over primitives and primitive pairs. We define new metrics obtained by Hamming distances over label graphs, which allow classification, segmentation and parsing errors to be characterized separately, or using a single measure. Recall and precision for detected objects may also be computed directly from label graphs. We illustrate the new metrics by comparing a new primitive-level evaluation to the symbol-level evaluation performed for the CROHME 2012 handwritten math recognition competition. A Python-based set of utilities for evaluating, visualizing and translating label graphs is publicly available.

  17. Assessment of safety margins in zircaloy oxidation and embrittlement criteria for ECCS acceptance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williford, R.E.

    1986-04-01

    Current Emergency Core Cooling System (ECCS) Acceptance Criteria for light-water reactors include certain requirements pertaining to calculations of core performance during a Loss of Coolant Accident (LOCA). The Baker-Just correlation must be used to calculate Zircaloy-steam oxidation, calculated peak cladding temperatures (PCT) must not exceed 1204/sup 0/C, and calculated oxidation must not exceed 17% equivalent cladding reacted (17% ECR). The minimum margin of safety was estimated for each of these criteria, based on research performed in the last decade. Margins were defined as the amounts of conservatism over and above the expected extreme values computed from the data base atmore » specified confidence levels. The currently required Baker-Just oxidation correlation provides margins only over the 1100/sup 0/C to 1500/sup 0/C temperature range at the 95% confidence level. The PCT margins for thermal shock and handling failures are adequate at oxidation temperatures above 1204/sup 0/C for 210 and 160 seconds, respectively, at the 95% confidence level. ECR thermal shock and handling margins at the 50% and 95% confidence levels, respectively, range between 2% and 7% ECR for the Baker-Just correlation, but vanish at temperatures between 1100/sup 0/C and 1160/sup 0/C for the best-estimate Cathcart-Pawel correlation. Use of the Cathcart-Pawel correlation for LOCA calculations can be justified at the 85% to 88% confidence level if cooling rate effects can be neglected. 75 refs., 21 figs.« less

  18. Time dependent wind fields

    NASA Technical Reports Server (NTRS)

    Chelton, D. B.

    1986-01-01

    Two tasks were performed: (1) determination of the accuracy of Seasat scatterometer, altimeter, and scanning multichannel microwave radiometer measurements of wind speed; and (2) application of Seasat altimeter measurements of sea level to study the spatial and temporal variability of geostrophic flow in the Antarctic Circumpolar Current. The results of the first task have identified systematic errors in wind speeds estimated by all three satellite sensors. However, in all cases the errors are correctable and corrected wind speeds agree between the three sensors to better than 1 ms sup -1 in 96-day 2 deg. latitude by 6 deg. longitude averages. The second task has resulted in development of a new technique for using altimeter sea level measurements to study the temporal variability of large scale sea level variations. Application of the technique to the Antarctic Circumpolar Current yielded new information about the ocean circulation in this region of the ocean that is poorly sampled by conventional ship-based measurements.

  19. High performance of PbSe/PbS core/shell quantum dot heterojunction solar cells: short circuit current enhancement without the loss of open circuit voltage by shell thickness control.

    PubMed

    Choi, Hyekyoung; Song, Jung Hoon; Jang, Jihoon; Mai, Xuan Dung; Kim, Sungwoo; Jeong, Sohee

    2015-11-07

    We fabricated heterojunction solar cells with PbSe/PbS core shell quantum dots and studied the precisely controlled PbS shell thickness dependency in terms of optical properties, electronic structure, and solar cell performances. When the PbS shell thickness increases, the short circuit current density (JSC) increases from 6.4 to 11.8 mA cm(-2) and the fill factor (FF) enhances from 30 to 49% while the open circuit voltage (VOC) remains unchanged at 0.46 V even with the decreased effective band gap. We found that the Fermi level and the valence band maximum level remain unchanged in both the PbSe core and PbSe/PbS core/shell with a less than 1 nm thick PbS shell as probed via ultraviolet photoelectron spectroscopy (UPS). The PbS shell reduces their surface trap density as confirmed by relative quantum yield measurements. Consequently, PbS shell formation on the PbSe core mitigates the trade-off relationship between the open circuit voltage and the short circuit current density. Finally, under the optimized conditions, the PbSe core with a 0.9 nm thick shell yielded a power conversion efficiency of 6.5% under AM 1.5.

  20. The next generation Ball 35 K cryocooler

    NASA Astrophysics Data System (ADS)

    Marquardt, E. D.; Gully, W. J.; Glaister, D. S.; Wright, G. P.

    2002-05-01

    This paper describes the development and performance of the Ball Aerospace (BATC) next generation cryocooler, also known as the SB235. Significant improvements in mass, power efficiency, and producibility have been incorporated into the SB235 design and development. The SB235 has twice the capacity of the current cryocoolers but with nearly the same mass and volume. It is over 25% more power efficient than BATC's current cryocoolers, which are industry leaders at temperatures below 60 K. The cooler has been redesigned at a component and subassembly level with an emphasis on producibility and repeatability. The cooler has 30% fewer parts than our current coolers. This, combined with significant improvements in procedures such as alignment, has resulted in a 50% reduction in production schedule. The SB235 has nominally been designed for 2-stage cooling with a design point of 1.0 W at 35 K while simultaneously cooling 2.0 W at 85 K. The cooler is ideally suited for long wavelength, MCT infrared sensor applications such as the Air Force SBIRS Low program. The performance of the SB235 cold head has been verified and integration with the SB235 compressor is nearly complete. Environmental testing will be completed by September 2001, and the proto-flight level cryocooler will enter life testing in October 2001.

  1. REVIEW OF MECHANISTIC UNDERSTANDING AND MODELING AND UNCERTAINTY ANALYSIS METHODS FOR PREDICTING CEMENTITIOUS BARRIER PERFORMANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langton, C.; Kosson, D.

    2009-11-30

    Cementitious barriers for nuclear applications are one of the primary controls for preventing or limiting radionuclide release into the environment. At the present time, performance and risk assessments do not fully incorporate the effectiveness of engineered barriers because the processes that influence performance are coupled and complicated. Better understanding the behavior of cementitious barriers is necessary to evaluate and improve the design of materials and structures used for radioactive waste containment, life extension of current nuclear facilities, and design of future nuclear facilities, including those needed for nuclear fuel storage and processing, nuclear power production and waste management. The focusmore » of the Cementitious Barriers Partnership (CBP) literature review is to document the current level of knowledge with respect to: (1) mechanisms and processes that directly influence the performance of cementitious materials (2) methodologies for modeling the performance of these mechanisms and processes and (3) approaches to addressing and quantifying uncertainties associated with performance predictions. This will serve as an important reference document for the professional community responsible for the design and performance assessment of cementitious materials in nuclear applications. This review also provides a multi-disciplinary foundation for identification, research, development and demonstration of improvements in conceptual understanding, measurements and performance modeling that would be lead to significant reductions in the uncertainties and improved confidence in the estimating the long-term performance of cementitious materials in nuclear applications. This report identifies: (1) technology gaps that may be filled by the CBP project and also (2) information and computational methods that are in currently being applied in related fields but have not yet been incorporated into performance assessments of cementitious barriers. The various chapters contain both a description of the mechanism or and a discussion of the current approaches to modeling the phenomena.« less

  2. Effect of Liquid Penetrant Sensitivity on Probability of Detection

    NASA Technical Reports Server (NTRS)

    Parker, Bradford H.

    2011-01-01

    The objective of the task is to investigate the effect of liquid penetrant sensitivity level on probability of detection (POD) of cracks in various metals. NASA-STD-5009 currently requires the use of only sensitivity level 4 liquid penetrants for NASA Standard Level inspections. This requirement is based on the fact that the data used to establish the reliably detectable flaw sizes penetrant inspection was from studies performed in the 1970s using penetrant deemed to be equivalent only to modern day sensitivity level 4 penetrants. However, many NDE contractors supporting NASA Centers routinely use sensitivity level 3 penetrants. Because of the new NASA-STD-5009 requirement, these contractors will have to either shift to sensitivity level 4 penetrants or perform formal POD demonstration tests to qualify their existing process. We propose a study to compare the POD generated for two penetrant manufactures, Sherwin and Magnaflux, and for the two most common penetrant inspection methods, water washable and post emulsifiable, hydrophilic. NDE vendors local to GSFC will be employed. A total of six inspectors will inspect a set of crack panels with a broad range of fatigue crack sizes. Each inspector will perform eight inspections of the panel set using the combination of methods and sensitivity levels described above. At least one inspector will also perform multiple inspections using a fixed technique to investigate repeatability. The hit/miss data sets will be evaluated using both the NASA generated DOEPOD software and the MIL-STD-1823 software.

  3. Performance improvement of doped TFET by using plasma formation concept

    NASA Astrophysics Data System (ADS)

    Soni, Deepak; Sharma, Dheeraj; Yadav, Shivendra; Aslam, Mohd.; Sharma, Neeraj

    2018-01-01

    Formation of abrupt doping profile at tunneling junction for the nanoscale tunnel field effect transistor (TFET) is a critical issue for attaining improved electrical behaviour. The realization of abrupt doping profile is more difficult in the case of physically doped TFETs due to material solubility limit. In this concern, we propose a novel design of TFET. For this, P+ (source)-I (channel)-N (drain) type structure has been considered, wherein a metal electrode is deposited over the source region. In addition to this, a negative voltage is applied to the source electrode (SE). It induces the surface plasma layer of holes in the source region, which is responsible for steepness in the bands at source/channel junction and provides the advantage of higher doping in source region without any addition of the physical impurity. The proposed modification is helpful for achieving steeper band bending at the source/channel interface, which enables higher tunneling generation rate of charge carriers at this interface and overcomes the issue of low ON-state current. Thus, the proposed device shows the increment of 2 decades in drain current and 252 mV reduction in threshold voltage compared with conventional device. The optimization of spacer length (LSG) between source/gate (LSG) and applied negative voltage (Vpg) over source electrode have been performed to obtain optimum drain current and threshold voltage (Vth). Further, for the suppression of ambipolar current, drain region is kept lightly doped, which reduces the ambipolar current up to level of Off state current. Moreover, in the proposed device gate electrode is underlapped for improving RF performance. It also reduces gate to drain capacitances (Cgd) and increases cut-off-frequency (fT), fmax, GBP, TFP. In addition to these, linearity analysis has been performed to validate the applicability of the device.

  4. Noise levels and their effects on Shuttle crewmembers' performance: Operational concerns

    NASA Technical Reports Server (NTRS)

    Koros, Anton S.; Adam, Susan C.; Wheelwright, Charles D.

    1993-01-01

    When excessive, noise can result in sleep interference, fatigue, interference with verbal communication, and hearing damage. Shuttle crewmembers are exposed to noise throughout their mission. The contribution of noise to decrements in crew performance over these extended exposure durations was the focus of this study. On the STS-40/SLS-1, mission noise levels were evaluated through the use of a sound level meter and a crew questionnaire. Crewmembers noted that sleep, concentration, and relaxation were negatively impacted by high noise levels. Speech Interference Levels (SIL's), calculated from the sound level measurements, suggested that crewmembers were required to raise their voice in order to be heard. No difficulty detecting caution and warning alarms was noted. The higher than desirable noise levels in Spacelab were attributed to flight specific payloads for which acoustic waivers were granted. It is recommended that current noise levels be reduced in Spacelab and the Orbiter Middeck especially as longer missions are planned for the buildup of Space Station Freedom. Levels of NC 50 are recommended in areas where speech communication is required and NC 40 in sleep areas. These levels are in accordance with the NASA Man-Systems Integration Standards. Measurements proposed for subsequent orbiter missions are discussed.

  5. In-pile electrochemical measurements on AISI 316 L(N) IG and EUROFER 97 I: experimental results

    NASA Astrophysics Data System (ADS)

    Vankeerberghen, Marc; Bosch, Rik-Wouter; Van Nieuwenhoven, Rudi

    2003-02-01

    In-pile electrochemical measurements were performed in order to investigate the effect of radiation on the electrochemical corrosion behaviour of two materials: reduced activation ferritic-martensitic steel EUROFER 97 and stainless steel AISI 316 L(N) IG. The corrosion potential was continuously monitored during the whole irradiation period. At regular intervals and under various flux levels, polarisation resistance measurements and electrochemical impedance spectroscopy were performed. Polarisation curves were recorded at the end of the reactor cycle. Analysis showed that the corrosion potential increased and the polarisation resistance decreased with the flux level. The impedance data showed two semi-circles in the Nyquist diagram which contracted with increasing flux level. A fit of the impedance data yielded a decrease of solution and polarisation resistances with the flux level. The polarisation curves could be fitted with a standard Butler-Volmer representation after correction for the solution resistance and showed an increase in the corrosion current density with the flux level.

  6. Design and performance of A 3He-free coincidence counter based on parallel plate boron-lined proportional technology

    DOE PAGES

    Henzlova, D.; Menlove, H. O.; Marlow, J. B.

    2015-07-01

    Thermal neutron counters utilized and developed for deployment as non-destructive assay (NDA) instruments in the field of nuclear safeguards traditionally rely on 3He-based proportional counting systems. 3He-based proportional counters have provided core NDA detection capabilities for several decades and have proven to be extremely reliable with range of features highly desirable for nuclear facility deployment. Facing the current depletion of 3He gas supply and the continuing uncertainty of options for future resupply, a search for detection technologies that could provide feasible short-term alternative to 3He gas was initiated worldwide. As part of this effort, Los Alamos National Laboratory (LANL) designedmore » and built a 3He-free full scale thermal neutron coincidence counter based on boron-lined proportional technology. The boronlined technology was selected in a comprehensive inter-comparison exercise based on its favorable performance against safeguards specific parameters. This paper provides an overview of the design and initial performance evaluation of the prototype High Level Neutron counter – Boron (HLNB). The initial results suggest that current HLNB design is capable to provide ~80% performance of a selected reference 3He-based coincidence counter (High Level Neutron Coincidence Counter, HLNCC). Similar samples are expected to be measurable in both systems, however, slightly longer measurement times may be anticipated for large samples in HLNB. The initial evaluation helped to identify potential for further performance improvements via additional tailoring of boron-layer thickness.« less

  7. Pointing control system design and performance evaluation of TPF coronagraph

    NASA Astrophysics Data System (ADS)

    Liu, Kuo-Chia; Blaurock, Carl; Mosier, Gary E.

    2004-09-01

    The Terrestrial Planet Finder (TPF) project aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the two mission concepts being studied. To reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of-sight (LOS) control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets or rotate around the LOS. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time. This paper provides an overview of the current control design concept and sensor/actuator topology for TPF Coronagraph and illustrates the fine pointing performance of the telescope. This performance is primarily a function of the rejection of high-frequency dynamic disturbances, in this case due to reaction wheel disturbance forces/torques transmitted through the passive isolation stage. Trade studies between isolator force rejection and disturbance level reduction via wheel redesign are also presented to illustrate the requirements imposed on current technologies. Finally, the paper summarizes preliminary results on the slew/settle performance of the telescope.

  8. Reported vocal habits of first-year undergraduate musical theater majors in a preprofessional training program: a 10-year retrospective study.

    PubMed

    Donahue, Erin N; Leborgne, Wendy D; Brehm, Susan Baker; Weinrich, Barbara D

    2014-05-01

    Collegiate-level musical theater performance students are a specialized group of vocal performers, who rely on frequent and optimal voice use for their academic advancement and ultimate livelihood. The purpose of this study was to gather information to develop a greater understanding of vocal health and practice patterns of incoming collegiate-level musical theater performers. Data obtained from questionnaires completed by freshman musical theater majors were retrospectively analyzed to gather information about baseline vocal habits of the participants. Results of a questionnaire were obtained from incoming freshman musical theater students at the Cincinnati Conservatory of Music over a period of 10 years (2002-2011). One hundred eighty-eight participants (female = 90) (male = 98) with an average age of 18.28 years (standard deviation = 0.726) were included. Results specifying participants' self-reported vocal training and practice habits, vocal health and hygiene practices, and current vocal symptoms or contributing factors to potential voice problems are provided. Data obtained from the participants revealed that the potential for vocal problems exists in this group of performers, as over half of the subjects reported at least one current negative vocal symptom. The findings from this study provide information that may be useful for individuals who are involved in the training of vocal performers. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  9. Relation of serum molindone levels to serum prolactin levels and antipsychotic response.

    PubMed

    Pandurangi, A K; Narasimhachari, N; Blackard, W G; Landa, B S

    1989-10-01

    The antipsychotic drug molindone is considered to be atypical in its mode of action and to have mild side effects. Currently no data are available on the range of serum levels of this drug during treatment. By means of a high performance liquid chromatographic technique, serum molindone levels were measured in 14 psychotic patients receiving a wide range of doses of this drug. Molindone levels as high as 350 ng/mL were obtained and were not associated with any toxic effects. Significant relations were noted between the serum level of the drug and both serum prolactin level and treatment response. The authors suggest that molindone may have a range of serum levels consistent with therapeutic benefit. Serum molindone and prolactin levels might help assess resistance to molindone treatment.

  10. Historic and current hepatitis B viral DNA and quantitative HBsAg level are not associated with cirrhosis in non-Asian women with chronic hepatitis B.

    PubMed

    Harkisoen, S; Arends, J E; van den Hoek, J A R; Whelan, J; van Erpecum, K J; Boland, G J; Hoepelman, A I M

    2014-12-01

    Some studies done in Asian patients have shown that serum levels of hepatitis B virus (HBV) DNA predict the development of cirrhosis. However, it is unclear whether this also applies for non-Asian patients. This study investigated historic and current HBV DNA and quantitative hepatitis B surface antigen (HBsAg) levels as predictors of cirrhosis in non-Asian women with chronic HBV. A retrospective cohort study of non-Asian women with chronic HBV was performed. Among other variables, HBV DNA and quantitative HBsAg levels were measured in stored historic serum samples obtained during pregnancy (period 1990-2004) and current serum samples (period 2011-2012) to determine any association with liver cirrhosis by liver stiffness measurement (LSM). One hundred and nineteen asymptomatic, treatment-naïve non-Asian women were included; the median number of years between the historic sample and the current sample was 17 (interquartile range (IQR) 13-20). The median historic log HBV DNA and quantitative log HBsAg levels were 2.5 (IQR 1.9-3.4) IU/ml and 4.2 (IQR 3.6-4.5) IU/ml, respectively. LSM diagnosed 14 patients (12%) with F3-F4 fibrosis, i.e. stiffness >8.1kPa. No association of cirrhosis was found with historic HBV DNA (relative risk (RR) 0.34, 95% confidence interval (CI) 0.05-2.44) or with the quantitative HBsAg level (HBsAg level >1000 IU/ml, RR 0.35, 95% CI 0.11-1.11). Multivariable analysis identified alcohol consumption (odds ratio (OR) 6.4, 95% CI 1.3-30.1), aspartate aminotransferase >0.5 times the upper limit of normal (OR 15.4, 95% CI 1.9-122.6), and prothrombin time (OR 12.0, 95% CI 1.2-120.4), but not HBV DNA or quantitative HBsAg level, to be independent predictors of the presence of cirrhosis. Neither historic nor current HBV DNA or the quantitative HBsAg level is associated with the development of HBV-related cirrhosis in non-Asian women. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Performance characteristics of ring-cusp thrusters with xenon propellant

    NASA Technical Reports Server (NTRS)

    Patterson, M. J.

    1986-01-01

    The performance characteristics and operating envelope of several 30-cm ring-cusp ion thrusters with xenon propellant were investigated. Results indicate a strong performance dependence on the discharge chamber boundary magnetic fields and resultant distribution of electron currents. Significant improvements in discharge performance over J-series divergent-field thrusters were achieved for large throttling ranges, which translate into reduced cathode emission currents and reduced power dissipation which should be of significant benefit for operation at thruster power levels in excess of 10 kW. Mass spectrometry of the ion beam was documented for both the ring-cusp and J-series thrusters with xenon propellant for determination of overall thruster efficiency, and lifetime. Based on the lower centerline values of doubly charged ions in the ion beam and the lower operating discharge voltage, the screen grid erosion rate of the ring-cusp thruster is expected to be lower than the divergent-field J-series thruster by a factor of 2.

  12. Performance characteristics of ring-cusp thrusters with xenon propellant

    NASA Technical Reports Server (NTRS)

    Patterson, M. J.

    1986-01-01

    The performance characteristics and operating envelope of several 30-cm ring-cusp ion thrusters with xenon propellant were investigated. Results indicate a strong performance dependence on the discharge chamber boundary magnetic fields and resultant distribution of electron currents. Significant improvements in discharge performance over J-series divergent-field thrusters were achieved for large throttling ranges, which translate into reduced cathode emission currents and reduced power dissipation which should be of significant benefit for operation at thruster power levels in excess of 10 kW. Mass spectrometer of the ion beam was documented for both the ring-cusp and J-series thrusters with xenon propellant for determination of overall thruster efficiency, and lifetime. Based on the lower centerline values of doubly charged ions in the ion beam and the lower operating discharge voltage, the screen grid erosion rate of the ring-cusp thruster is expected to be lower than the divergent-field J-series thruster by a factor of 2.

  13. Adding Fault Tolerance to NPB Benchmarks Using ULFM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parchman, Zachary W; Vallee, Geoffroy R; Naughton III, Thomas J

    2016-01-01

    In the world of high-performance computing, fault tolerance and application resilience are becoming some of the primary concerns because of increasing hardware failures and memory corruptions. While the research community has been investigating various options, from system-level solutions to application-level solutions, standards such as the Message Passing Interface (MPI) are also starting to include such capabilities. The current proposal for MPI fault tolerant is centered around the User-Level Failure Mitigation (ULFM) concept, which provides means for fault detection and recovery of the MPI layer. This approach does not address application-level recovery, which is currently left to application developers. In thismore » work, we present a mod- ification of some of the benchmarks of the NAS parallel benchmark (NPB) to include support of the ULFM capabilities as well as application-level strategies and mechanisms for application-level failure recovery. As such, we present: (i) an application-level library to checkpoint and restore data, (ii) extensions of NPB benchmarks for fault tolerance based on different strategies, (iii) a fault injection tool, and (iv) some preliminary results that show the impact of such fault tolerant strategies on the application execution.« less

  14. [Breast feeding and systemic blood pressure in infants].

    PubMed

    Hernández-González, Martha A; Díaz-De-León, Luz V; Guízar-Mendoza, Juan M; Amador-Licona, Norma; Cipriano-González, Marisol; Díaz-Pérez, Raúl; Murillo-Ortiz, Blanca O; De-la-Roca-Chiapas, José María; Solorio-Meza, Sergio Eduardo

    2012-01-01

    Blood pressure levels in childhood influence these levels in adulthood, and breastfeeding has been considered such as a cardioprotective. We evaluated the association between blood pressure levels and feeding type in a group of infants. We conducted a comparative cross-sectional study in term infants with appropriate weight at birth, to compare blood pressure levels in those children with exclusively breastfeeding, mixed-feeding and formula feeding. The comparison of groups was performed using ANOVA and multiple regression analysis was used to identify variables associated with mean arterial blood pressure levels. A p value < 0.05 was considered significant. We included 20 men and 24 women per group. Infant Formula Feeding had higher current weight and weight gain compared with the other two groups (p < 0.05). Systolic, diastolic and mean blood pressure levels, as well as respiratory and heart rate were higher in the groups of exclusively formula feeding and mixed-feeding than in those with exclusively breastfeeding (p < 0.05). Multiple regression analysis identified that variables associated with mean blood pressure levels were current body mass index, weight gain and formula feeding. Infants in breastfeeding show lower blood pressure, BMI and weight gain.

  15. Influence of trap-assisted tunneling on trap-assisted tunneling current in double gate tunnel field-effect transistor

    NASA Astrophysics Data System (ADS)

    Zhi, Jiang; Yi-Qi, Zhuang; Cong, Li; Ping, Wang; Yu-Qi, Liu

    2016-02-01

    Trap-assisted tunneling (TAT) has attracted more and more attention, because it seriously affects the sub-threshold characteristic of tunnel field-effect transistor (TFET). In this paper, we assess subthreshold performance of double gate TFET (DG-TFET) through a band-to-band tunneling (BTBT) model, including phonon-assisted scattering and acoustic surface phonons scattering. Interface state density profile (Dit) and the trap level are included in the simulation to analyze their effects on TAT current and the mechanism of gate leakage current. Project supported by the National Natural Science Foundation of China (Grant Nos. 61574109 and 61204092).

  16. A simulation-based study of HighSpeed TCP and its deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souza, Evandro de

    2003-05-01

    The current congestion control mechanism used in TCP has difficulty reaching full utilization on high speed links, particularly on wide-area connections. For example, the packet drop rate needed to fill a Gigabit pipe using the present TCP protocol is below the currently achievable fiber optic error rates. HighSpeed TCP was recently proposed as a modification of TCP's congestion control mechanism to allow it to achieve reasonable performance in high speed wide-area links. In this research, simulation results showing the performance of HighSpeed TCP and the impact of its use on the present implementation of TCP are presented. Network conditions includingmore » different degrees of congestion, different levels of loss rate, different degrees of bursty traffic and two distinct router queue management policies were simulated. The performance and fairness of HighSpeed TCP were compared to the existing TCP and solutions for bulk-data transfer using parallel streams.« less

  17. Extended Performance 8-cm Mercury Ion Thruster

    NASA Technical Reports Server (NTRS)

    Mantenieks, M. A.

    1981-01-01

    A slightly modified 8-cm Hg ion thruster demonstrated significant increase in performance. Thrust was increased by almost a factor of five over that of the baseline thruster. Thruster operation with various three grid ion optics configurations; thruster performance as a function of accelerator grid open area, cathode baffle, and cathode orifice size; and a life test of 614 hours at a beam current of 250 mA (17.5 mN thrust) are discussed. Highest thruster efficiency was obtained with the smallest open area accelerator grid. The benefits in efficiency from the low neutral loss grids were mitigated, however, by the limitation such grids place on attainable ion beam current densities. The thruster components suffered negligible weight losses during a life test, which indicated that operation of the 8-cm thruster at extended levels of thrust and power is possible with no significant loss of lifetime.

  18. Cooperation driven coherence: Brains working hard together.

    PubMed

    Bezerianos, Anastasios; Sun, Yu; Chen, Yu; Woong, Kian Fong; Taya, Fumihiko; Arico, Pietro; Borghini, Gianluca; Babiloni, Fabio; Thakor, Nitish

    2015-01-01

    The current study aims to look at the difference in coupling of EEG activity of participant pairs while they perform a cooperative, concurrent, independent yet different task at high and low difficulty levels. Participants performed the National Aeronautics and Space Administration (NASA) designed Multi-Attribute Task Battery (MATB-II) task which simulates a pilot and copilot operating an aircraft. Each participant in the pair was responsible for 2 out of 4 subtasks which were independent and different from one another while all tasks occurs concurrently in real time with difficulty levels being the frequency that adjustments are required for each subtask. We found that as the task become more difficult, there was more coupling between the pilot and copilot.

  19. Runway Scheduling for Charlotte Douglas International Airport

    NASA Technical Reports Server (NTRS)

    Malik, Waqar A.; Lee, Hanbong; Jung, Yoon C.

    2016-01-01

    This paper describes the runway scheduler that was used in the 2014 SARDA human-in-the-loop simulations for CLT. The algorithm considers multiple runways and computes optimal runway times for departures and arrivals. In this paper, we plan to run additional simulation on the standalone MRS algorithm and compare the performance of the algorithm against a FCFS heuristic where aircraft avail of runway slots based on a priority given by their positions in the FCFS sequence. Several traffic scenarios corresponding to current day traffic level and demand profile will be generated. We also plan to examine the effect of increase in traffic level (1.2x and 1.5x) and observe trends in algorithm performance.

  20. Ultralife's polymer electrolyte rechargeable lithium-ion batteries for use in the mobile electronics industry

    NASA Astrophysics Data System (ADS)

    Cuellar, Edward A.; Manna, Michael E.; Wise, Ralph D.; Gavrilov, Alexei B.; Bastian, Matthew J.; Brey, Rufus M.; DeMatteis, Jeffrey

    Ultralife Polymer™ brand batteries for cellular phones as made by Nokia Mobile Phones Incorporated were introduced in July 2000. Characteristics of the UBC443483 cell and UB750N battery are described and related to the power and battery requirements of these cellular phones and chargers. Current, power, and pulse capability are presented as functions of temperature, depth of discharge, and storage at the cell level. Safety protection devices and chargers are discussed at the battery pack level, as well as performance in cellular phones under various wireless communication protocols. Performance is competitive with liquid lithium-ion systems while offering opportunity for non-traditional form factors.

  1. A Performance Assessment of a Tactical Airborne Separation Assistance System using Realistic, Complex Traffic Flows

    NASA Technical Reports Server (NTRS)

    Smith, Jeremy C.; Neitzke, Kurt W.; Bussink, Frank J. L.

    2008-01-01

    This paper presents the results from a study that investigates the performance of aspects of an Airborne Separation Assistance System (ASAS) under varying demand levels using realistic traffic patterns. This study only addresses the tactical aspects of an ASAS using aircraft state data (latitude, longitude, altitude, heading and speed) to detect and resolve projected conflicts. The main focus of this paper is to determine the extent to which sole reliance on the proposed tactical ASAS can maintain aircraft separation at demand levels up to three times current traffic. The effect of mixing ASAS equipped aircraft with non-equipped aircraft that do not have the capability to self-separate is also investigated.

  2. A double-risk monitoring and movement restriction policy for Ebola entry screening at airports in the United States.

    PubMed

    Jacobson, Sheldon H; Yu, Ge; Jokela, Janet A

    2016-07-01

    This paper provides an alternative policy for Ebola entry screening at airports in the United States. This alternative policy considers a social contact tracing (SCT) risk level, in addition to the current health risk level used by the CDC. The performances of both policies are compared based on the scenarios that occur and the expected cost associated with implementing such policies. Sensitivity analysis is performed to identify conditions under which one policy dominates the other policy. This analysis takes into account that the alternative policy requires additional data collection, which is balanced by a more cost-effective allocation of resources. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Is positive thinking in anticipation of a performance situation better than distraction? An experimental study in preadolescents.

    PubMed

    Vassilopoulos, Stephanos P; Brouzos, Andreas; Tsorbatzoudis, Haralambos; Tziouma, Olga

    2017-04-01

    The current study compares the effects of experimentally induced positive anticipatory thinking and distraction in preadolescents aged 12-13. Eighty-seven participants were instructed to either engage in positive anticipatory thoughts or perform a distraction task while preparing to perform a sporting activity in front of their peers. Results revealed that trait social anxiety was associated with more negative estimates of sport performance and catastrophic thoughts relating to the impending sport activity. Additionally, compared to children who distracted, children in the positive anticipation condition showed significantly increased anxiety levels, more catastrophic thoughts and more negative predictions of sport performance and appearance, although these effects did not appear to interact with trait social anxiety. Finally, no significant manipulation effect on participants' observable behavior was found. The findings further highlight the utility of distracting from an impending, anxiety-provoking situation to keep anxious feelings to a low level. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  4. Markovian prediction of future values for food grains in the economic survey

    NASA Astrophysics Data System (ADS)

    Sathish, S.; Khadar Babu, S. K.

    2017-11-01

    Now-a-days prediction and forecasting are plays a vital role in research. For prediction, regression is useful to predict the future value and current value on production process. In this paper, we assume food grain production exhibit Markov chain dependency and time homogeneity. The economic generative performance evaluation the balance time artificial fertilization different level in Estrusdetection using a daily Markov chain model. Finally, Markov process prediction gives better performance compare with Regression model.

  5. Studies to design and develop improved remote manipulator systems

    NASA Technical Reports Server (NTRS)

    Hill, J. W.; Sword, A. J.

    1973-01-01

    Remote manipulator control considered is based on several levels of automatic supervision which derives manipulator commands from an analysis of sensor states and task requirements. Principle sensors are manipulator joint position, tactile, and currents. The tactile sensor states can be displayed visually in perspective or replicated in the operator's control handle of perceived by the automatic supervisor. Studies are reported on control organization, operator performance and system performance measures. Unusual hardware and software details are described.

  6. Tighter accuracy standards within point-of-care blood glucose monitoring: how six commonly used systems compare.

    PubMed

    Robinson, Charlotte S; Sharp, Patrick

    2012-05-01

    Blood glucose monitoring systems (BGMS) are used in the hospital environment to manage blood glucose levels in patients at the bedside. The International Organization for Standardization (ISO) 15197:2003 standard is currently used by regulatory bodies as a minimum requirement for the performance of BGMS, specific to self-testing. There are calls for the tightening of accuracy requirements and implementation of a standard specifically for point-of-care (POC) BGMS. The accuracy of six commonly used BGMS was assessed in a clinical setting, with 108 patients' finger stick capillary samples. Using the accuracy criteria from the existing standard and a range of tightened accuracy criteria, system performance was compared. Other contributors to system performance have been measured, including hematocrit sensitivity and meter error rates encountered in the clinical setting. Five of the six BGMS evaluated met current accuracy criteria within the ISO 15197 standard. Only the Optium Xceed system had >95% of all readings within a tightened criteria of ±12.5% from the reference at glucose levels ≥72 mg/dl (4 mmol/liter) and ±9 mg/dl (0.5 mmol/liter) at glucose levels <72 mg/dl (4 mmol/liter). The Nova StatStrip Xpress had the greatest number of error messages observed; Optium Xceed the least. OneTouch Ultra2, Nova StatStrip Xpress, Accu-Chek Performa, and Contour TS products were all significantly influenced by blood hematocrit levels. From evidence obtained during this clinical evaluation, the Optium Xceed system is most likely to meet future anticipated accuracy standards for POC BGMS. In this clinical study, the results demonstrated the Optium Xceed product to have the highest level of accuracy, to have the lowest occurrence of error messages, and to be least influenced by blood hematocrit levels. © 2012 Diabetes Technology Society.

  7. Rising temperatures may drive fishing-induced selection of low-performance phenotypes

    PubMed Central

    Clark, Timothy D.; Messmer, Vanessa; Tobin, Andrew J.; Hoey, Andrew S.; Pratchett, Morgan S.

    2017-01-01

    Climate warming is likely to interact with other stressors to challenge the physiological capacities and survival of phenotypes within populations. This may be especially true for the billions of fishes per year that undergo vigorous exercise prior to escaping or being intentionally released from fishing gear. Using adult coral grouper (Plectropomus leopardus), an important fisheries species throughout the Indo-Pacific, we show that population-level survival following vigorous exercise is increasingly compromised as temperatures increase from current-day levels (100–67% survival at 24–30 °C) to those projected for the end of the century (42% survival at 33 °C). Intriguingly, we demonstrate that high-performance individuals take longer to recover to a resting metabolic state and subsequently have lower survival in warm water compared with conspecifics that exercise less vigorously. Moreover, we show that post-exercise mortality of high-performance phenotypes manifests after 3–13 d at the current summer maximum (30 °C), while mortality at 33 °C occurs within 1.8–14.9 h. We propose that wild populations in a warming climate may become skewed towards low-performance phenotypes with ramifications for predator-prey interactions and community dynamics. Our findings highlight the susceptibility of phenotypic diversity to fishing activities and demonstrate a mechanism that may contribute to fishing-induced evolution in the face of ongoing climate change. PMID:28094310

  8. Cost aware cache replacement policy in shared last-level cache for hybrid memory based fog computing

    NASA Astrophysics Data System (ADS)

    Jia, Gangyong; Han, Guangjie; Wang, Hao; Wang, Feng

    2018-04-01

    Fog computing requires a large main memory capacity to decrease latency and increase the Quality of Service (QoS). However, dynamic random access memory (DRAM), the commonly used random access memory, cannot be included into a fog computing system due to its high consumption of power. In recent years, non-volatile memories (NVM) such as Phase-Change Memory (PCM) and Spin-transfer torque RAM (STT-RAM) with their low power consumption have emerged to replace DRAM. Moreover, the currently proposed hybrid main memory, consisting of both DRAM and NVM, have shown promising advantages in terms of scalability and power consumption. However, the drawbacks of NVM, such as long read/write latency give rise to potential problems leading to asymmetric cache misses in the hybrid main memory. Current last level cache (LLC) policies are based on the unified miss cost, and result in poor performance in LLC and add to the cost of using NVM. In order to minimize the cache miss cost in the hybrid main memory, we propose a cost aware cache replacement policy (CACRP) that reduces the number of cache misses from NVM and improves the cache performance for a hybrid memory system. Experimental results show that our CACRP behaves better in LLC performance, improving performance up to 43.6% (15.5% on average) compared to LRU.

  9. Anesthesia Practice and Clinical Trends in Interventional Radiology: A European Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haslam, Philip J.; Yap, Bernard; Mueller, Peter R.

    Purpose: To determine current European practice in interventional radiology regarding nursing care, anesthesia, and clinical care trends.Methods: A survey was sent to 977 European interventional radiologists to assess the use of sedoanalgesia, nursing care, monitoring equipment, pre- and postprocedural care, and clinical trends in interventional radiology. Patterns of sedoanalgesia were recorded for both vascular and visceral interventional procedures. Responders rated their preferred level of sedoanalgesia for each procedure as follows: (a) awake/alert, (b) drowsy/arousable, (c) asleep/arousable, (d) deep sedation, and (e) general anesthesia. Sedoanalgesic drugs and patient care trends were also recorded. A comparison was performed with data derived frommore » a similar survey of interventional practice in the United States.Results: Two hundred and forty-three of 977 radiologists responded (25%). The total number of procedures analyzed was 210,194. The majority (56%) of diagnostic and therapeutic vascular procedures were performed at the awake/alert level of sedation, 32% were performed at the drowsy/arousable level, and 12% at deeper levels of sedation. The majority of visceral interventional procedures were performed at the drowsy/arousable level of sedation (41%), 29% were performed at deeper levels of sedation, and 30% at the awake/alert level. In general, more sedoanalgesia is used in the United States. Eighty-three percent of respondents reported the use of a full-time radiology nurse, 67% used routine blood pressure/pulse oximetry monitoring, and 46% reported the presence of a dedicated recovery area. Forty-nine percent reported daily patient rounds, 30% had inpatient hospital beds, and 51% had day case beds.Conclusion: This survey shows clear differences in the use of sedation for vascular and visceral interventional procedures. Many, often complex, procedures are performed at the awake/alert level of sedation in Europe, whereas deeper levels of sedation are used in the United States. Trends toward making interventional radiology a clinical specialty are evident, with 51% of respondents having day case beds, and 30% having inpatient beds.« less

  10. Vitamin D and Exercise Performance in Professional Soccer Players

    PubMed Central

    Koundourakis, Nikolaos E.; Androulakis, Nikolaos E.; Malliaraki, Niki; Margioris, Andrew N.

    2014-01-01

    Aim The current study had two aims. The primary purpose was to examine the association between serum vitamin D levels and the ergometric evaluation of muscle strength, aerobic capacity, and speed in professional soccer players. The secondary aim was to evaluate the effects of the soccer off-season period on serum vitamin D levels. Methods Sixty-seven Caucasian male soccer players (age 25.6±6.2 and height 1.81±0.08 m), members of two Greek Superleague Soccer teams and one Football-league championship team participated in this study. Exercise performance testing for the determination of squat jump (SJ), countermovement jump (CMJ), 10 (10 m) and 20 meters (20 m) sprint performance, maximal oxygen consumption (VO2max), anthropometry, and blood sampling were performed before (pre) and after (post) the six-week off-season period. Results Analysis of our results showed the following: (a) a significant correlations between serum vitamin D levels and performance parameters in both pre (SJ; P<0.001, CMJ; P<0.001, VO2max; P<0.001, 10 m; P<0.001, and 20 m; P<0.001) and post (SJ; P<0.001, CMJ; P<0.001, VO2max; P = 0.006, 10 m; P<0.001, and 20 m; P<0.001) experimental sessions. (b) Vitamin D concentration increased significantly (P<0.001) following the six-week off-season period compared to baseline, while at the same time all measured performance parameters decreased (SJ; P<0.001, CMJ; P<0.001, 10 m; P<0.001, 20 m; P<0.001, VO2max; P<0.001). Discussion Our findings suggest that vitamin D levels are associated with the ergometric evaluation of muscle strength, as expressed by SJ and CMJ, sprinting capacity, and VO2max in professional soccer players, irrespective the levels of performance. Furthermore, our data reaffirm the importance of UVB on serum vitamin D levels. Moreover, reductions in exercise training stress may also have beneficial effects on vitamin D levels, suggesting a possible association of its levels and the training-induced stress. Our results indicate a possibly bidirectional interaction between soccer performance indices and vitamin D levels. PMID:24992690

  11. Preliminary Results of Performance Measurements on a Cylindrical Hall-Effect Thruster with Magnetic Field Generated by Permanent Magnets

    NASA Technical Reports Server (NTRS)

    Polzin, K. A.; Raitses, Y.; Merino, E.; Fisch, N. J.

    2008-01-01

    The performance of a low-power cylindrical Hall thruster, which more readily lends itself to miniaturization and low-power operation than a conventional (annular) Hall thruster, was measured using a planar plasma probe and a thrust stand. The field in the cylindrical thruster was produced using permanent magnets, promising a power reduction over previous cylindrical thruster iterations that employed electromagnets to generate the required magnetic field topology. Two sets of ring-shaped permanent magnets are used, and two different field configurations can be produced by reorienting the poles of one magnet relative to the other. A plasma probe measuring ion flux in the plume is used to estimate the current utilization for the two magnetic configurations. The measurements indicate that electron transport is impeded much more effectively in one configuration, implying a higher thrust efficiency. Preliminary thruster performance measurements on this configuration were obtained over a power range of 100-250 W. The thrust levels over this power range were 3.5-6.5 mN, with anode efficiencies and specific impulses spanning 14-19% and 875- 1425 s, respectively. The magnetic field in the thruster was lower for the thrust measurements than the plasma probe measurements due to heating and weakening of the permanent magnets, reducing the maximum field strength from 2 kG to roughly 750-800 G. The discharge current levels observed during thrust stand testing were anomalously high compared to those levels measured in previous experiments with this thruster.

  12. High performance ripple feedback for the buck unity-power-factor rectifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo, Y.W.; King, R.J.

    1995-03-01

    The buck unity-power-factor rectifier has harmonic-free input current with complete load regulation down to zero output voltage. A new ``nonlinear ripple feedback`` is proposed which exactly cancels the spoiling effect of dc-side current ripple on the low-distortion ac line current waveforms, even for large amounts of ripple. This cancellation is independent of operating point and readily implemented with analog hardware, thereby permitting economies in the design of the dc filter while maintaining harmonic-free operation. Both large-signal and incremental analyses of the rectifier are given. Confirming experimental results from a 1-kW 48-V isolated battery charger operating with current-ripple levels ranging frommore » 50% to discontinuous-conduction-mode operation are given.« less

  13. Argobots: A Lightweight Low-Level Threading and Tasking Framework

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Sangmin; Amer, Abdelhalim; Balaji, Pavan

    In the past few decades, a number of user-level threading and tasking models have been proposed in the literature to address the shortcomings of OS-level threads, primarily with respect to cost and flexibility. Current state-of-the-art user-level threading and tasking models, however, either are too specific to applications or architectures or are not as powerful or flexible. In this paper, we present Argobots, a lightweight, low-level threading and tasking framework that is designed as a portable and performant substrate for high-level programming models or runtime systems. Argobots offers a carefully designed execution model that balances generality of functionality with providing amore » rich set of controls to allow specialization by end users or high-level programming models. We describe the design, implementation, and performance characterization of Argobots and present integrations with three high-level models: OpenMP, MPI, and colocated I/O services. Evaluations show that (1) Argobots, while providing richer capabilities, is competitive with existing simpler generic threading runtimes; (2) our OpenMP runtime offers more efficient interoperability capabilities than production OpenMP runtimes do; (3) when MPI interoperates with Argobots instead of Pthreads, it enjoys reduced synchronization costs and better latency-hiding capabilities; and (4) I/O services with Argobots reduce interference with colocated applications while achieving performance competitive with that of a Pthreads approach.« less

  14. Comparative investigation of vibration and current monitoring for prediction of mechanical and electrical faults in induction motor based on multiclass-support vector machine algorithms

    NASA Astrophysics Data System (ADS)

    Gangsar, Purushottam; Tiwari, Rajiv

    2017-09-01

    This paper presents an investigation of vibration and current monitoring for effective fault prediction in induction motor (IM) by using multiclass support vector machine (MSVM) algorithms. Failures of IM may occur due to propagation of a mechanical or electrical fault. Hence, for timely detection of these faults, the vibration as well as current signals was acquired after multiple experiments of varying speeds and external torques from an experimental test rig. Here, total ten different fault conditions that frequently encountered in IM (four mechanical fault, five electrical fault conditions and one no defect condition) have been considered. In the case of stator winding fault, and phase unbalance and single phasing fault, different level of severity were also considered for the prediction. In this study, the identification has been performed of the mechanical and electrical faults, individually and collectively. Fault predictions have been performed using vibration signal alone, current signal alone and vibration-current signal concurrently. The one-versus-one MSVM has been trained at various operating conditions of IM using the radial basis function (RBF) kernel and tested for same conditions, which gives the result in the form of percentage fault prediction. The prediction performance is investigated for the wide range of RBF kernel parameter, i.e. gamma, and selected the best result for one optimal value of gamma for each case. Fault predictions has been performed and investigated for the wide range of operational speeds of the IM as well as external torques on the IM.

  15. The NASA/USAF arcjet research and technology program

    NASA Technical Reports Server (NTRS)

    Stone, James R.; Huston, Edward S.

    1987-01-01

    Direct current arcjets have the potential to provide specific impulses greater than 500 sec with storable propellants, and greater than 1000 sec with hydrogen. This level of performance can provide significant benefits for such applications as orbit transfer, station keeping, orbit change, and maneuvering. The simplicity of the arcjet system and its elements of commonality with state-of-the-art resistojet systems offer a relatively low risk transition to these enhanced levels of performance for low power (0.5 to 1.5 kW) station keeping applications. Arcjets at power levels of 10 to 30 kW are potentially applicable to orbit transfer missions. Furthermore, with the anticipated development of space nuclear power systems, arcjets at greater than 100 kW may become attractive. This paper describes the ongoing NASA/USAF program and describes major recent accomplishments.

  16. [Analysis of the natural radioactivity due to the radon gas in the underground of Rome].

    PubMed

    Magrini, A; Grana, M; Gianello, G; La Bua, R; Laurini, C; Messina, A; Pagliari, E; Bergamaschi, A

    2007-01-01

    Radon is a decay product of 238Uranium which is classified by WHO/IARC as group 1 carcinogen, given its causal relationship with lung neoplasia. An annual concentration of this gas higher than 500 Bq/m3 in workplace is considered potentially dangerous by the italian legislation. No data are currently available on radon level in underground tunnels, which are a potentially important source of exposure both for workers and travellers. Measurements have been performed in a station and within the trains. Two months integrated measures, and 5 days continuous (hourly) assessments have been performed. Integrated measurements have been performed by means of 12 passive dosimeters, containing a detector made of CR39 (polymeric type), whereas active scintillation-type dosimeters have been employed for continuous assessments. Two months integrated measures: radon level in the station was 665 +/- 71 Bq/m3, whereas values within the trains ranged between 96 and 117 Bq/m3. Continuous measurements: Mean radon level during work activities was 783 +/- 536 Bq/m3 and thereafter it rose to 850 +/- 131 Bq/m3 Radon nelle levels in underground tunnels may exceed attention levels, whereas within trains they remain well below these levels. Further studies focused to assess the risk of underground employers are needed.

  17. When self-efficacy negatively relates to motivation and performance in a learning context.

    PubMed

    Vancouver, Jeffrey B; Kendall, Laura N

    2006-09-01

    Recent reviews of the training literature have advocated directly manipulating self-efficacy in an attempt to improve the motivation of trainees. However, self-regulation theories conceive of motivation as a function of various goal processes, and assert that the effect of self-efficacy should depend on the process involved. Training contexts may evoke planning processes in which self-efficacy might negatively relate to motivation. Yet the typical between-persons studies in the current literature may obscure the effect. To examine this issue, 63 undergraduate students completed a series of questionnaires measuring self-efficacy and motivation before 5 class exams. Self-efficacy was negatively related to motivation and exam performance at the within-person level of analysis, despite a significant positive relation with performance at the between-persons level. (c) 2006 APA, all rights reserved

  18. Performance of a Block Structured, Hierarchical Adaptive MeshRefinement Code on the 64k Node IBM BlueGene/L Computer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greenough, Jeffrey A.; de Supinski, Bronis R.; Yates, Robert K.

    2005-04-25

    We describe the performance of the block-structured Adaptive Mesh Refinement (AMR) code Raptor on the 32k node IBM BlueGene/L computer. This machine represents a significant step forward towards petascale computing. As such, it presents Raptor with many challenges for utilizing the hardware efficiently. In terms of performance, Raptor shows excellent weak and strong scaling when running in single level mode (no adaptivity). Hardware performance monitors show Raptor achieves an aggregate performance of 3:0 Tflops in the main integration kernel on the 32k system. Results from preliminary AMR runs on a prototype astrophysical problem demonstrate the efficiency of the current softwaremore » when running at large scale. The BG/L system is enabling a physics problem to be considered that represents a factor of 64 increase in overall size compared to the largest ones of this type computed to date. Finally, we provide a description of the development work currently underway to address our inefficiencies.« less

  19. Encoding and choice in the task span paradigm.

    PubMed

    Reiman, Kaitlin M; Weaver, Starla M; Arrington, Catherine M

    2015-03-01

    Cognitive control during sequences of planned behaviors requires both plan-level processes such as generating, maintaining, and monitoring the plan, as well as task-level processes such as selecting, establishing and implementing specific task sets. The task span paradigm (Logan in J Exp Psychol Gen 133:218-236, 2004) combines two common cognitive control paradigms, task switching and working memory span, to investigate the integration of plan-level and task-level processes during control of sequential behavior. The current study expands past task span research to include measures of encoding processes and choice behavior with volitional sequence generation, using the standard task span as well as a novel voluntary task span paradigm. In two experiments, we consider how sequence complexity, defined separately for plan-level and task-level complexity, influences sequence encoding (Experiment 1), sequence choice (Experiment 2), sequence memory, and task performance of planned sequences of action. Results indicate that participants were sensitive to sequence complexity, but that different aspects of behavior are most strongly influenced by different types of complexity. Hierarchical complexity at the plan level best predicts voluntary sequence generation and memory; while switch frequency at the task level best predicts encoding of externally defined sequences and task performance. Furthermore, performance RTs were similar for externally and internally defined plans, whereas memory was improved for internally defined sequences. Finally, participants demonstrated a significant sequence choice bias in the voluntary task span. Consistent with past research on choice behavior, volitional selection of plans was markedly influenced by both the ease of memory and performance.

  20. Electrical field imaging as a means to predict the loudness of monopolar and tripolar stimuli in cochlear implant patients.

    PubMed

    Berenstein, Carlo K; Vanpoucke, Filiep J; Mulder, Jef J S; Mens, Lucas H M

    2010-12-01

    Tripolar and other electrode configurations that use simultaneous stimulation inside the cochlea have been tested to reduce channel interactions compared to the monopolar stimulation conventionally used in cochlear implant systems. However, these "focused" configurations require increased current levels to achieve sufficient loudness. In this study, we investigate whether highly accurate recordings of the intracochlear electrical field set up by monopolar and tripolar configurations correlate to their effect on loudness. We related the intra-scalar potential distribution to behavioral loudness, by introducing a free parameter (α) which parameterizes the degree to which the potential field peak set up inside the scala tympani is still present at the location of the targeted neural tissue. Loudness balancing was performed on four levels between behavioral threshold and the most comfortable loudness level in a group of 10 experienced Advanced Bionics cochlear implant users. The effect of the amount of focusing on loudness was well explained by α per subject location along the basilar membrane. We found that α was unaffected by presentation level. Moreover, the ratios between the monopolar and tripolar currents, balanced for equal loudness, were approximately the same for all presentation levels. This suggests a linear loudness growth with increasing current level and that the equal peak hypothesis may predict the loudness of threshold as well as at supra-threshold levels. These results suggest that advanced electrical field imaging, complemented with limited psychophysical testing, more specifically at only one presentation level, enables estimation of the loudness growth of complex electrode configurations. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Strategies toward High Performance Organic Photovoltaic Cell: Material and Process

    NASA Astrophysics Data System (ADS)

    Kim, Bong Gi

    The power conversion efficiency of organic photovoltaic (OPV) cells has been rapidly improved during the last few years and currently reaches around 10 %. The performance is evenly governed by absorption, exciton diffusion, exciton dissociation, carrier transfer, and collection efficiencies. Establishing a better understanding of OPV device physics combined with the development of new materials for each executive step contributes to this dramatic improvement. This dissertation focuses mainly on material design and development to correlate the intrinsic properties of organic semiconductors and the OPV performance. The introductory Chapter 1 briefly reviews the motivation of OPV research, its working mechanism, and representative organic materials for OPV application. Chapter 2 discusses the modulation of conjugated polymer's (CP's) absorption behavior and an efficient semi-empirical approach to predict CP's energy levels from its constituent monomers' HOMO/LUMO values. A strong acceptor lowered both the HOMO and LUMO levels of the CP, but the LUMO dropped more rapidly which ultimately produced a narrowed band-gap in the electron donating/accepting alternating copolymer system. In addition, the energy level difference between the CP and the constituent monomers converged to a constant value, providing an energy level prediction tool. Chapter 3 illustrates the systematic investigation on the relationship between the molecular structure of an energy harvesting organic dye and the exciton dissociation efficiency. The study showed that the quantum yield decreased as the exciton binding energy increases, and dipole moment direction should be properly oriented in the dye framework in order to improve photo-current generation when used in a dye sensitized photovoltaic device. Chapter 4 demonstrates the ultrasonic-assisted self-assembly of CPs in solution, rapidly and efficiently. Ultrasonication combined with dipolar media accelerated CP's aggregation, and the effect of CP's aggregation on the enhancement of OPV performance by promoting photo-current generation and increasing carrier mobility was systematically investigated. The correlation between the chemical structure of a CP and it aggregation behavior is further described in Chapter 5. To promote CP aggregate, a planar chain conformation was advantageous and CP aggregation improved hole mobility in the OPV device. However, thermally induced CP aggregates caused strong charge recombination, resulting in open circuit voltage drop. In Chapter 6, a novel polymer design principle to enable directed CP alignment is discussed. Regulating chain planarity and preventing massive crystallization of CP achieved by the developed molecular design principle allowed directed CP alignment under small shear flow.

  2. Different Effects of Adding White Noise on Cognitive Performance of Sub-, Normal and Super-Attentive School Children

    PubMed Central

    Helps, Suzannah K.; Bamford, Susan; Sonuga-Barke, Edmund J. S.; Söderlund, Göran B. W.

    2014-01-01

    Objectives Noise often has detrimental effects on performance. However, because of the phenomenon of stochastic resonance (SR), auditory white noise (WN) can alter the “signal to noise” ratio and improve performance. The Moderate Brain Arousal (MBA) model postulates different levels of internal “neural noise” in individuals with different attentional capacities. This in turn determines the particular WN level most beneficial in each individual case–with one level of WN facilitating poor attenders but hindering super-attentive children. The objective of the present study is to find out if added WN affects cognitive performance differently in children that differ in attention ability. Methods Participants were teacher-rated super- (N = 25); normal- (N = 29) and sub-attentive (N = 36) children (aged 8 to 10 years). Two non-executive function (EF) tasks (a verbal episodic recall task and a delayed verbal recognition task) and two EF tasks (a visuo-spatial working memory test and a Go-NoGo task) were performed under three WN levels. The non-WN condition was only used to control for potential differences in background noise in the group testing situations. Results There were different effects of WN on performance in the three groups-adding moderate WN worsened the performance of super-attentive children for both task types and improved EF performance in sub-attentive children. The normal-attentive children’s performance was unaffected by WN exposure. The shift from moderate to high levels of WN had little further effect on performance in any group. Significance The predicted differential effect of WN on performance was confirmed. However, the failure to find evidence for an inverted U function challenges current theories. Alternative explanations are discussed. We propose that WN therapy should be further investigated as a possible non-pharmacological treatment for inattention. PMID:25393410

  3. Low dark current MCT-based focal plane detector arrays for the LWIR and VLWIR developed at AIM

    NASA Astrophysics Data System (ADS)

    Gassmann, Kai Uwe; Eich, Detlef; Fick, Wolfgang; Figgemeier, Heinrich; Hanna, Stefan; Thöt, Richard

    2015-10-01

    For nearly 40 years AIM develops, manufactures and delivers photo-voltaic and photo-conductive infrared sensors and associated cryogenic coolers which are mainly used for military applications like pilotage, weapon sights, UAVs or vehicle platforms. In 2005 AIM started to provide the competences also for space applications like IR detector units for the SLSTR instrument on board of the Sentinel 3 satellite, the hyperspectral SWIR Imager for EnMAP or pushbroom detectors for high resolution Earth observation satellites. Meanwhile AIM delivered more than 25 Flight Models for several customers. The first European pulse-tube cooler ever operating on-board of a satellite is made by AIM. AIM homes the required infrared core capabilities such as design and manufacturing of focal plane assemblies, detector housing technologies, development and manufacturing of cryocoolers and also data processing for thermal IR cameras under one roof which enables high flexibility to react to customer needs and assures economical solutions. Cryogenically cooled Hg(1-x)CdxTe (MCT) quantum detectors are unequalled for applications requiring high imaging as well as high radiometric performance in the infrared spectral range. Compared with other technologies, they provide several advantages, such as the highest quantum efficiency, lower power dissipation compared to photoconductive devices and fast response times, hence outperforming micro-bolometer arrays. However, achieving an excellent MCT detector performance at long (LWIR) and very long (VLWIR) infrared wavelengths is challenging due to the exponential increase in the thermally generated photodiode dark current with increasing cut-off wavelength and / or operating temperature. Dark current is a critical design driver, especially for LWIR / VLWIR multi-spectral imagers with moderate signal levels or hyper-spectral Fourier spectrometers operating deep into the VLWIR spectral region. Consequently, low dark current (LDC) technologies are the prerequisite for future scientific space and earth observation missions. Aiming, for example at exoplanet or earth atmospheric spectral analysis, significant improvement in LWIR / VLWIR detector material performance is mandatory. LDC material optimization can target different directions of impact: (i) reduction of dark current for a given operational temperature to increase SNR and reduce thermally induced signal offset variations. (ii) operation at elevated temperatures at a given dark current level to reduce mass and power budget of the required cryocooler and to reduce cryostat complexity. (iii) increase the accessible cut-off wavelength at constant detector temperature and dark current level. This paper presents AIM's latest results on n-on-p as well as p-on-n low dark current planar MCT photodiode focal plane detector arrays at cut-off wavelengths >11 μm at 80 K. Dark current densities below Tennant's `Rule07'1 have been demonstrated for n-on-p and p-on-n devices. This work has been carried out under ESA contract ESTEC 4000107414/13/NL/SFe².

  4. Hyperactivity in Attention-Deficit/Hyperactivity Disorder (ADHD): Impairing Deficit or Compensatory Behavior?

    PubMed

    Sarver, Dustin E; Rapport, Mark D; Kofler, Michael J; Raiker, Joseph S; Friedman, Lauren M

    2015-10-01

    Excess gross motor activity (hyperactivity) is considered a core diagnostic feature of childhood ADHD that impedes learning. This view has been challenged, however, by recent models that conceptualize excess motor activity as a compensatory mechanism that facilitates neurocognitive functioning in children with ADHD. The current study investigated competing model predictions regarding activity level's relation with working memory (WM) performance and attention in boys aged 8-12 years (M = 9.64, SD = 1.26) with ADHD (n = 29) and typically developing children (TD; n = 23). Children's phonological WM and attentive behavior were objectively assessed during four counterbalanced WM tasks administered across four separate sessions. These data were then sequenced hierarchically based on behavioral observations of each child's gross motor activity during each task. Analysis of the relations among intra-individual changes in observed activity level, attention, and performance revealed that higher rates of activity level predicted significantly better, but not normalized WM performance for children with ADHD. Conversely, higher rates of activity level predicted somewhat lower WM performance for TD children. Variations in movement did not predict changes in attention for either group. At the individual level, children with ADHD and TD children were more likely to be classified as reliably Improved and Deteriorated, respectively, when comparing their WM performance at their highest versus lowest observed activity level. These findings appear most consistent with models ascribing a functional role to hyperactivity in ADHD, with implications for selecting behavioral treatment targets to avoid overcorrecting gross motor activity during academic tasks that rely on phonological WM.

  5. Critical thinking traits of top-tier experts and implications for computer science education

    NASA Astrophysics Data System (ADS)

    Bushey, Dean E.

    A documented shortage of technical leadership and top-tier performers in computer science jeopardizes the technological edge, security, and economic well-being of the nation. The 2005 President's Information and Technology Advisory Committee (PITAC) Report on competitiveness in computational sciences highlights the major impact of science, technology, and innovation in keeping America competitive in the global marketplace. It stresses the fact that the supply of science, technology, and engineering experts is at the core of America's technological edge, national competitiveness and security. However, recent data shows that both undergraduate and postgraduate production of computer scientists is falling. The decline is "a quiet crisis building in the United States," a crisis that, if allowed to continue unchecked, could endanger America's well-being and preeminence among the world's nations. Past research on expert performance has shown that the cognitive traits of critical thinking, creativity, and problem solving possessed by top-tier performers can be identified, observed and measured. The studies show that the identified attributes are applicable across many domains and disciplines. Companies have begun to realize that cognitive skills are important for high-level performance and are reevaluating the traditional academic standards they have used to predict success for their top-tier performers in computer science. Previous research in the computer science field has focused either on programming skills of its experts or has attempted to predict the academic success of students at the undergraduate level. This study, on the other hand, examines the critical-thinking skills found among experts in the computer science field in order to explore the questions, "What cognitive skills do outstanding performers possess that make them successful?" and "How do currently used measures of academic performance correlate to critical-thinking skills among students?" The results of this study suggest a need to examine how critical-thinking abilities are learned in the undergraduate computer science curriculum and the need to foster these abilities in order to produce the high-level, critical-thinking professionals necessary to fill the growing need for these experts. Due to the fact that current measures of academic performance do not adequately depict students' cognitive abilities, assessment of these skills must be incorporated into existing curricula.

  6. Survey of Musculoskeletal Disorders Among Indian Dancers in Mumbai and Mangalore.

    PubMed

    Nair, Shruti Prabhakaran; Kotian, Shruti; Hiller, Claire; Mullerpatan, Rajani

    2018-06-15

    Classical Indian dance has earned recognition across the globe; however, the health of dancers who are carrying forth this heritage has not received due attention. Therefore, this study aimed to explore musculoskeletal pain and injury prevailing among Indian dancers in Mumbai and Mangalore. A secondary aim was to compare pain tolerance levels between dancers and non-dancers. Fifty-one dancers trained in different traditional Indian and Western dance forms and 164 recreational dancers were recruited as participants. An indigenous questionnaire was designed and validated by physical therapists across various levels of experience and dancers across various training levels. The questionnaire recorded dance, pain, and injury profiles. Additionally, pain tolerance was evaluated using the Pain Sensitivity Questionnaire among dancers and healthy age- and gender-matched controls (N = 200). Descriptive statistical analysis was performed to present results of the site of current pain, site of past injury, perceived causes of injury, and exercise routine. The Student's t-test was used to compare Pain Sensitivity Questionnaire scores between dancers and non-dancers, and independent one-way ANOVA was used to compare scores among dancers practicing different dance forms. For both current pain and past injury, dancers reported the back (42.5%) followed by the knee (28.3%) and ankle (18.6%) as the most common sites. Stress was the most commonly perceived cause of injury (34.4%), followed by over work (24.7%), tiredness (17.2%), and falls (13.5%). Warm-up exercises were always performed by 43.30% of dancers, whereas only 20% performed stretching after dance. Almost 60% of dancers participated in forms of exercise other than dance, e.g., swimming, yoga, and aerobics. Pain sensitivity was not significantly different between dancers and non-dancers (p = 0.159). Level of training and gender did not influence pain.

  7. Autism-relevant traits interact with temporoparietal junction stimulation effects on social cognition: a high-definition transcranial direct current stimulation and electroencephalography study.

    PubMed

    Donaldson, Peter H; Kirkovski, Melissa; Rinehart, Nicole J; Enticott, Peter G

    2018-03-01

    The temporoparietal junction (TPJ) is implicated in mental and emotional state attribution, processes associated with autism-relevant traits. Transcranial direct current stimulation (tDCS) to the TPJ can influence social-cognitive performance. However, associations with electrophysiology and autism-relevant traits remain relatively unexamined. This study had two aims: first, exploring links between Autism-Spectrum Quotient (AQ) scores and social-cognitive performance; second, examining interactions between AQ scores and high-definition-tDCS (HD-tDCS) applied to the right TPJ in terms of mental/emotional state attribution and neurophysiological outcomes. Fifty-three participants completed mental/emotional state attribution tasks before and after HD-tDCS. Pre-stimulation mental state attribution accuracy was reduced in participants with higher AQ Switching scores. Cathodal stimulation was associated with reduced emotion attribution performance in participants with higher AQ Switching and AQ Social scores (the latter at trend-level). Anodal stimulation more frequently interacted with AQ Social scores in terms of neurophysiology, in particular regarding reduced delta power in the left compared to right TPJ, and trend-level positive interactions with P100 and P300 latencies during the emotion recognition task. Elements of attention/switching (AQ Switching) may subserve or underpin elements of social cognition (AQ Social), and cathodal and anodal stimulation may have differing effects depending on trait levels in these domains. This study makes an important and original contribution in terms of increasing understanding of how such trait-level variation might interact with the effects of tDCS and also extending previous studies with regard to understanding potential roles of the rTPJ in both attention and social cognition and how autism-relevant traits might influence TPJ function. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  8. A Fourier Method for Sidelobe Reduction in Equally Spaced Linear Arrays

    NASA Astrophysics Data System (ADS)

    Safaai-Jazi, Ahmad; Stutzman, Warren L.

    2018-04-01

    Uniformly excited, equally spaced linear arrays have a sidelobe level larger than -13.3 dB, which is too high for many applications. This limitation can be remedied by nonuniform excitation of array elements. We present an efficient method for sidelobe reduction in equally spaced linear arrays with low penalty on the directivity. The method involves the following steps: construction of a periodic function containing only the sidelobes of the uniformly excited array, calculation of the Fourier series of this periodic function, subtracting the series from the array factor of the original uniformly excited array after it is truncated, and finally mitigating the truncation effects which yields significant increase in sidelobe level reduction. A sidelobe reduction factor is incorporated into element currents that makes much larger sidelobe reductions possible and also allows varying the sidelobe level incrementally. It is shown that such newly formed arrays can provide sidelobe levels that are at least 22.7 dB below those of the uniformly excited arrays with the same size and number of elements. Analytical expressions for element currents are presented. Radiation characteristics of the sidelobe-reduced arrays introduced here are examined, and numerical results for directivity, sidelobe level, and half-power beam width are presented for example cases. Performance improvements over popular conventional array synthesis methods, such as Chebyshev and linear current tapered arrays, are obtained with the new method.

  9. Clover as a tool for bioindication of phytotoxic ozone--5 years of experience from southern Sweden--consequences for the short-term critical levels.

    PubMed

    Karlsson, Gunilla Pihl; Karlsson, Per Erik; Danielsson, Helena; Pleijel, Håkan

    2003-01-01

    Critical levels (CLs) for ozone effects on plants in Europe have been defined within the UN-ECE Convention on Long-Range Transboundary Air Pollution, CLRTAP. The purpose of the short-term CLs is to ensure protection of all crops to acute ozone injury. The currently used CLs are based on the ozone exposure of the plants during daylight hours expressed as AOT40 (Accumulated exposure Over the Threshold 40 nmol mol(-1) ozone). The aims of this study were: to test the performance of the current short-term CLs, to test alternative ozone exposure indices and to test if changes in the ozone cut-off concentration, the inclusion of a lag-period (LP) between exposure and identification of visible ozone injury or the duration of the ozone integration period improved the performance of the exposure index. The analysis was based on 38 different datasets from experiments with subterranean clover, Trifolium subterraneum in southern Sweden. AOT indices generally performed better than averaged ozone concentrations or SUM (Sum of ozone concentrations when a threshold is exceeded) indices. Regression analysis showed that the current short-term CL, AOT40 with a VPD (water vapour pressure deficit) threshold of 1.5 kPa, explained 56% of the variation in visible injury. A longer exposure period and the introduction of a LP, admitting visible ozone injury time to develop after exposure, improved the performance of the exposure index. AOT30 accumulated over 10 days before harvest, excluding a LP of 3 days before injury observation, performed best and explained 88% of the variation in visible injury. AOT40 indices left a rather large amount of visible injury unexplained indicating that a lower cut-off concentration for ozone is preferable. The results of the investigation indicated that a visible injury threshold of 10% improved the distinction between harmful and less harmful exposure. Copyright 2002 Elsevier Science B.V.

  10. Ramp compression of a metallic liner driven by a shaped 5 MA current on the SPHINX machine

    NASA Astrophysics Data System (ADS)

    d'Almeida, T.; Lassalle, F.; Morell, A.; Grunenwald, J.; Zucchini, F.; Loyen, A.; Maysonnave, T.; Chuvatin, A.

    2014-05-01

    SPHINX is a 6MA, 1-us Linear Transformer Driver operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. A method for performing magnetic ramp compression experiments was developed using a compact Dynamic Load Current Multiplier inserted between the convolute and the load, to shape the initial current pulse. We present the overall experimental configuration chosen for these experiments and initial results obtained over a set of experiments on an aluminum cylindrical liner. Current profiles measured at various critical locations across the system, are in good agreement with simulated current profiles. The liner inner free surface velocity measurements agree with the hydrocode results obtained using the measured load current as the input. The potential of the technique in terms of applications and achievable ramp pressure levels lies in the prospects for improving the DLCM efficiency.

  11. Why Do Rereading Lag Effects Depend on Test Delay?

    ERIC Educational Resources Information Center

    Rawson, Katherine A.

    2012-01-01

    In previous research, rereading after a long lag versus a short lag led to greater performance on delayed tests but not on immediate tests. The current study tested two accounts of why the effects of rereading lag depend on test delay. The "levels of representation" ("LOR") "hypothesis" states that the effects reflect…

  12. Ghanaian Students in TIMSS 2011: Relationship between Contextual Factors and Mathematics Performance

    ERIC Educational Resources Information Center

    Butakor, Paul Kwame; Ampadu, Ernest; Cole, Yaa

    2017-01-01

    Educational effectiveness research has witnessed some growth in the last three decades because the current era of global competitiveness compels each country to train and equip its citizens with knowledge and skills that would make them successful. Researchers from different countries are investigating factors across various levels within the…

  13. Component Processes Subserving Rapid Automatized Naming in Dyslexic and Non-Dyslexic Readers

    ERIC Educational Resources Information Center

    Araujo, Susana; Inacio, Filomena; Francisco, Ana; Faisca, Luis; Petersson, Karl Magnus; Reis, Alexandra

    2011-01-01

    The current study investigated which time components of rapid automatized naming (RAN) predict group differences between dyslexic and non-dyslexic readers (matched for age and reading level), and how these components relate to different reading measures. Subjects performed two RAN tasks (letters and objects), and data were analyzed through a…

  14. Challenges and Opportunities in Adult Education.

    ERIC Educational Resources Information Center

    Brand, Betsy

    Literacy and work force preparedness are two of the most important issues facing education today. Findings of nationwide studies show that reading and writing performance of students is inadequate. One of every eight current workers reads at the fourth-grade level or lower. The nation's economic future will be determined by the quality and…

  15. A Replication of Failure, Not a Failure to Replicate

    ERIC Educational Resources Information Center

    Holden, Gary; Barker, Kathleen; Kuppens, Sofie; Rosenberg, Gary; LeBreton, Jonathan

    2015-01-01

    Purpose: The increasing role of systematic reviews in knowledge production demands greater rigor in the literature search process. The performance of the Social Work Abstracts (SWA) database has been examined multiple times over the past three decades. The current study is a replication within this line of research. Method: Issue-level coverage…

  16. Acetone Enhances the Direct Analysis of Total Condensed Tannins in Forage Legumes by the Butanol-HCl Assay

    USDA-ARS?s Scientific Manuscript database

    Depending on concentration, condensed tannins (CT) in forages have no effect, enhance, or impede protein utilization and performance of ruminants. Defining optimal forage CT levels has been elusive, partly because current methods for estimating total soluble plus insoluble CT are laborious or inaccu...

  17. Experimental design for drifting buoy Lagrangian test

    NASA Technical Reports Server (NTRS)

    Saunders, P. M.

    1975-01-01

    A test of instrumentation fabricated to measure the performance of a free drifting buoy as a (Lagrangian) current meter is described. Specifically it is proposed to distinguish between the trajectory of a drogued buoy and the trajectory of the water at the level of the drogue by measuring the flow relative to the drogue.

  18. Expertise-Based Differences in Search and Option-Generation Strategies

    ERIC Educational Resources Information Center

    Raab, Markus; Johnson, Joseph G.

    2007-01-01

    The current work builds on option-generation research using experts of various skill levels in a realistic task. We extend previous findings that relate an athlete's performance strategy to generated options and subsequent choices in handball. In a 2-year longitudinal study, we present eye-tracking data to independently verify decision strategies…

  19. Evaluating High School Students' Anxiety and Self-Efficacy towards Biology

    ERIC Educational Resources Information Center

    Çimen, Osman; Yilmaz, Mehmet

    2015-01-01

    Anxiety and self-efficacy are among the factors that impact students' performance in biology. The current study aims to investigate high school students' perception of biology anxiety and self-efficacy, in relation to gender, grade level, interest in biology, negative experience associated with biology classes, and teachers' approaches in the…

  20. Race, Test Scores, and Educational Outcomes

    ERIC Educational Resources Information Center

    Yeh, Stuart S.

    2016-01-01

    Background: Policymakers wish to know what changes must be made to the primary and secondary education system so that when students apply to college they are highly prepared, ready to perform at high levels, and likely to be successful in college. Purpose: The purpose of the current study was to investigate the significance of strong educational…

  1. Perform an investigation of the effects of increased reclaimed asphalt pavement (RAP) levels in dense graded friction courses : [summary].

    DOT National Transportation Integrated Search

    2015-04-01

    The Florida Department of Transportation currently allows up to 20% recycled asphalt : pavement (RAP) in asphalt mixes to be used for roadway surfaces. The abundance of RAP and : savings in cost and to natural resources make increased use of RAP desi...

  2. Increasing Math Milieu Teaching by Varying Levels of Consultation Support: An Example of Analyzing Intervention Strength

    ERIC Educational Resources Information Center

    Marsicano, Richard T.; Morrison, Julie Q.; Moomaw, Sally C.; Fite, Nathan M.; Kluesener, Courtney M.

    2015-01-01

    The current study used a single-case design to examine two performance feedback conditions varying in intensity on the frequency of naturalistic math instruction in preschool classrooms during non-instructional times (transition, lunch, free play). Three Head Start teachers received professional development that combined information on four…

  3. Sentence Processing: Psycholinguistic Studies Presented to Merrill Garrett.

    ERIC Educational Resources Information Center

    Cooper, William E., Ed.; Walker, Edward C. T., Ed.

    The chapters in this volume represent a type of current psycholinguistic research that focuses both on the nature of human information processing and the coding of linguistic structure. The chapters and authors are as follows: (1) "The Wherefores and Therefores of the Competence-Performance Distinction," by V. Valian; (2) "Levels of Processing and…

  4. An Orientable Search Coil

    ERIC Educational Resources Information Center

    Holt, P. J.; Poblocki, M.

    2017-01-01

    We provide a design for a low cost orientable search coil that can be used to investigate the variation of magnetic flux with angle. This experiment is one of the required practical activities in the current A level physics specification for the AQA examination board in the UK. We demonstrate its performance and suggest other suitable…

  5. State Standards Rise in Reading, Fall in Math

    ERIC Educational Resources Information Center

    Peterson, Paul E.; Lastra-Anadon, Carlos Xabel

    2010-01-01

    Much ado has been made about setting high standards over the past year. Current conversations about creating a common national standard largely focus on the substantive curriculum to be taught at various grade levels. Even more important is each state's expectations for student performance with respect to the curriculum, as expressed through its…

  6. Second Language Comprehensibility Revisited: Investigating the Effects of Learner Background

    ERIC Educational Resources Information Center

    Crowther, Dustin; Trofimovich, Pavel; Saito, Kazuya; Isaacs, Talia

    2015-01-01

    The current study investigated first language (L1) effects on listener judgment of comprehensibility and accentedness in second language (L2) speech. The participants were 45 university-level adult speakers of English from three L1 backgrounds (Chinese, Hindi, Farsi), performing a picture narrative task. Ten native English listeners used…

  7. Please, Not Another Push to Get Tough on Student Retention

    ERIC Educational Resources Information Center

    Norton, M. Scott

    2011-01-01

    Standardized academic testing, under-performing schools, demands for high standards in America's schools and current levels of student dropouts have resulted in renewed calls for "getting tough on student retention." The push for student retention is demanded by school boards and others in spite of the overwhelming research evidence that…

  8. Current food safety management systems in fish-exporting companies require further improvements to adequately cope with contextual pressure: case study.

    PubMed

    Onjong, Hillary Adawo; Wangoh, John; Njage, Patrick Murigu Kamau

    2014-10-01

    Fish-processing plants still face food safety (FS) challenges worldwide despite the existence of several quality assurance standards and food safety management systems/s (FSMSs). This study assessed performance of FSMS in fish exporting sector considering pressure from the context in which they operate. A FSMS diagnostic tool with checklist was used to assess the context, FSMS, and FS output in 9 Kenyan fish exporting companies. Majority (67%) companies operated at moderate- to high-risk context but with an average performance in control and assurance activities. This situation could be insufficient to deal with ambiguity, uncertainty, and vulnerability issues in the context characteristics. Contextual risk posed by product characteristics (nature of raw materials) and chain environment characteristics was high. Risk posed by the chain environment characteristics, low power in supplier relationships, and low degree of authority in customer relationships was high. Lack of authority in relationship with suppliers would lead to high raw material risk situation. Even though cooling facilities, a key control activity, was at an advanced level, there was inadequate packaging intervention equipment which coupled with inadequate physical intervention equipment could lead to further weakened FSMS performance. For the fish companies to improve their FSMS to higher level and enhance predictability, they should base their FSMS on scientific information sources, historical results, and own experimental trials in their preventive, intervention, and monitoring systems. Specific suggestions are derived for improvements toward higher FSMS activity levels or lower risk levels in context characteristics. Weak areas in performance of control and assurance activities in export fish-processing sector already implementing current quality assurance guidelines and standards were studied taking into consideration contextual pressure wherein the companies operate. Important mitigation measures toward improved contextual risk, core assurance, and control activities irrespective of applied food safety management systems in fish industries were suggested. © 2014 Institute of Food Technologists®

  9. [The study of establishment of the " Chinese provincial Blindness prevention technical guidance group performance evaluation system"].

    PubMed

    Lu, L N; He, X G; Zhu, J F; Xu, X; Zhang, R; Hu, X; Zou, H D

    2016-11-11

    Objective: To establish an assessment system, including indexes and scoring methods, that can be used for performance evaluation of the provincial blindness prevention technical guidance group properly and effectively . Methods: The indexes and scoring methods were set based on the core content of The " National Plan of Prevention and Treatment of Blindness (2012-2015)" , the specific requirement and target of the World Health Organization (WHO) "For the General Eye Health: Global plan of Action (2014-2019)" , and the current situation of the China's provinces and autonomous regions. These indexes should be of effectiveness, feasibility, comparability, guidance and advancing. Formed by a literature review of candidate indicators, the framework of the system is built by qualitative assessment. With the Delphi method, the system was further revised and improved. Empirical pilot study was then used to prove the feasibility, followed by the final qualitative analysis that establish the " Chinese provincial Blindness prevention technical guidance group performance evaluation system" . Results: Through the literature review and qualitative assessment, a six dimensional system framework was built, including 6 first-level indicators, 16 second-level indicators, and 29 third-level indicators through Delphi method evaluation. With the variation coefficient method, the coeffiences of the first-level index weight were calculated as: Organization and management 0.15, Development and implementation of blindness prevention plans 0.15, Implementation of blindness prevention projects 0.14, Training 0.17, Health education 0.18, and Cooperation and exchanges 0.21. The specific scoring method for this system is confirmed as: data and files check, field interview, and record interview, sampling investigation. Empirical pilot study was conducted in the Jilin, Guizhou and Gansu provinces, and the self-assessment results from local experts were consistent with the scores from the systems. Conclusion: This system established is appropriate at current time, and it can effectively evaluate the performance of the Chinese provincial Blindness prevention technical guidance group. (Chin J Ophthalmol, 2016, 52:814-824) .

  10. The Great British Medalists Project: A Review of Current Knowledge on the Development of the World's Best Sporting Talent.

    PubMed

    Rees, Tim; Hardy, Lew; Güllich, Arne; Abernethy, Bruce; Côté, Jean; Woodman, Tim; Montgomery, Hugh; Laing, Stewart; Warr, Chelsea

    2016-08-01

    The literature base regarding the development of sporting talent is extensive, and includes empirical articles, reviews, position papers, academic books, governing body documents, popular books, unpublished theses and anecdotal evidence, and contains numerous models of talent development. With such a varied body of work, the task for researchers, practitioners and policy makers of generating a clear understanding of what is known and what is thought to be true regarding the development of sporting talent is particularly challenging. Drawing on a wide array of expertise, we address this challenge by avoiding adherence to any specific model or area and by providing a reasoned review across three key overarching topics: (a) the performer; (b) the environment; and (c) practice and training. Within each topic sub-section, we review and calibrate evidence by performance level of the samples. We then conclude each sub-section with a brief summary, a rating of the quality of evidence, a recommendation for practice and suggestions for future research. These serve to highlight both our current level of understanding and our level of confidence in providing practice recommendations, but also point to a need for future studies that could offer evidence regarding the complex interactions that almost certainly exist across domains.

  11. The Relationship Between Pitching Mechanics and Injury: A Review of Current Concepts

    PubMed Central

    Chalmers, Peter N.; Wimmer, Markus A.; Verma, Nikhil N.; Cole, Brian J.; Romeo, Anthony A.; Cvetanovich, Gregory L.; Pearl, Michael L.; Chalmers, Peter N.; Wimmer, Markus A.; Verma, Nikhil N.; Cole, Brian J.; Romeo, Anthony A.; Cvetanovich, Gregory L.; Pearl, Michael L.

    2017-01-01

    Context: The overhand pitch is one of the fastest known human motions and places enormous forces and torques on the upper extremity. Shoulder and elbow pain and injury are common in high-level pitchers. A large body of research has been conducted to understand the pitching motion. Evidence Acquisition: A comprehensive review of the literature was performed to gain a full understanding of all currently available biomechanical and clinical evidence surrounding pitching motion analysis. These motion analysis studies use video motion analysis, electromyography, electromagnetic sensors, and markered motion analysis. This review includes studies performed between 1983 and 2016. Study Design: Clinical review. Level of Evidence: Level 5. Results: The pitching motion is a kinetic chain, in which the force generated by the large muscles of the lower extremity and trunk during the wind-up and stride phases are transferred to the ball through the shoulder and elbow during the cocking and acceleration phases. Numerous kinematic factors have been identified that increase shoulder and elbow torques, which are linked to increased risk for injury. Conclusion: Altered knee flexion at ball release, early trunk rotation, loss of shoulder rotational range of motion, increased elbow flexion at ball release, high pitch velocity, and increased pitcher fatigue may increase shoulder and elbow torques and risk for injury. PMID:28107113

  12. Probing the Complexities of Structural Changes in Layered Oxide Cathode Materials for Li-Ion Batteries during Fast Charge–Discharge Cycling and Heating

    DOE PAGES

    Hu, Enyuan; Wang, Xuelong; Yu, Xiqian; ...

    2018-01-19

    The rechargeable lithium-ion battery (LIB) is the most promising energy storage system to power electric vehicles with high energy density and long cycling life. However, in order to meet customers’ demands for fast charging, the power performances of current LIBs need to be improved. From the cathode aspect, layer-structured cathode materials are widely used in today’s market and will continue to play important roles in the near future. The high rate capability of layered cathode materials during charging and discharging is critical to the power performance of the whole cell and the thermal stability is closely related to the safetymore » issues. Therefore, the in-depth understanding of structural changes of layered cathode materials during high rate charging/discharging and the thermal stability during heating are essential in developing new materials and improving current materials. Since structural changes take place from the atomic level to the whole electrode level, combination of characterization techniques covering multilength scales is quite important. Finally, in many cases, this means using comprehensive tools involving diffraction, spectroscopy, and imaging to differentiate the surface from the bulk and to obtain structural/chemical information with different levels of spatial resolution.« less

  13. A Comparison of Three Determinants of an Engagement Index for Use in a Simulated Flight Environment

    NASA Technical Reports Server (NTRS)

    Hitt, James M., II

    1995-01-01

    The following report details a project design that is to be completed by the end of the year. Determining how engaged a person is at a task is rather difficult. There are many different ways to assess engagement. One such method is to use psychophysical measures. The current study focuses on three determinants of an engagement index proposed by researchers at NASA-Langley (Pope, A. T., Bogart, E. H., and Bartolome, D. S., 1995). The index (20 Beta/(Alpha+Theta)) uses EEG power bands to determine a person's level of engagement while performs a compensatory tracking task. The tracking task switches between manual and automatic modes. Participants each experience both positive and negative feedback within each trial of the three trials. The tracking task is altered in terms of difficulty depending on the participants current engagement index. The rationale of this study is to determine the optimal level of engagement to gain peak performance. The three determinants are based on an absolute index which differs from the past research which uses a slope index.

  14. Risk Aversion and Public Reporting. Part 2: Mitigation Strategies.

    PubMed

    Shahian, David M; Jacobs, Jeffrey P; Badhwar, Vinay; D'Agostino, Richard S; Bavaria, Joseph E; Prager, Richard L

    2017-12-01

    Part 1 of this review summarizes the consequences of risk aversion and the observational studies and surveys relevant to this phenomenon, almost all of which are derived from cardiac surgery and interventional cardiology. In Part 2, we describe the root cause of risk aversion-the belief by providers that current risk adjustment is inadequate to account for the severity of their highest-risk patients, thereby prejudicing their publicly reported performance scores. Evidence supporting the robustness of current risk adjustment is presented, as well as nine potential strategies to further mitigate risk aversion: optimization of data source, risk models, and performance measures; exclusion of high-risk patients; exclusion of non-procedure-related end points; separate reporting of high-risk patients; reporting by condition or diagnosis rather than by procedures; reporting at the hospital or program level rather than the physician level; collaborative, cross-disciplinary decision making; active surveillance for risk aversion; and improved stakeholder education. Of these, the first is most desirable, widely applicable, and resistant to gaming. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment

    PubMed Central

    Van Such, Monica B.; Nesse, Robert E.; Dilling, James A.; Swensen, Stephen J.; Thompson, Kristine M.; Orlowski, Janis M.; Santrach, Paula J.

    2017-01-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices. In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias. With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions. PMID:28353502

  16. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment.

    PubMed

    Naessens, James M; Van Such, Monica B; Nesse, Robert E; Dilling, James A; Swensen, Stephen J; Thompson, Kristine M; Orlowski, Janis M; Santrach, Paula J

    2017-07-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices.In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias.With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions.

  17. Situation awareness-based agent transparency for human-autonomy teaming effectiveness

    NASA Astrophysics Data System (ADS)

    Chen, Jessie Y. C.; Barnes, Michael J.; Wright, Julia L.; Stowers, Kimberly; Lakhmani, Shan G.

    2017-05-01

    We developed the Situation awareness-based Agent Transparency (SAT) model to support human operators' situation awareness of the mission environment through teaming with intelligent agents. The model includes the agent's current actions and plans (Level 1), its reasoning process (Level 2), and its projection of future outcomes (Level 3). Human-inthe-loop simulation experiments have been conducted (Autonomous Squad Member and IMPACT) to illustrate the utility of the model for human-autonomy team interface designs. Across studies, the results consistently showed that human operators' task performance improved as the agents became more transparent. They also perceived transparent agents as more trustworthy.

  18. Sterilization, high-level disinfection, and environmental cleaning.

    PubMed

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  19. Procedure and information displays in advanced nuclear control rooms: experimental evaluation of an integrated design.

    PubMed

    Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan

    2017-08-01

    In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.

  20. Literature Review on Needs of Upper Limb Prosthesis Users.

    PubMed

    Cordella, Francesca; Ciancio, Anna Lisa; Sacchetti, Rinaldo; Davalli, Angelo; Cutti, Andrea Giovanni; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out the main critical aspects of the current prosthetic solutions, in terms of users satisfaction and activities of daily living they would like to perform with the prosthetic device. The ultimate goal is to provide design inputs in the prosthetic field and, contemporary, increase user satisfaction rates and reduce device abandonment. A list of requirements for upper limb prostheses is proposed, grounded on the performed analysis on user needs. It wants to (i) provide guidelines for improving the level of acceptability and usefulness of the prosthesis, by accounting for hand functional and technical aspects; (ii) propose a control architecture of PNS-based prosthetic systems able to satisfy the analyzed user wishes; (iii) provide hints for improving the quality of the methods (e.g., questionnaires) adopted for understanding the user satisfaction with their prostheses.

  1. Current status and future prospects of power generators using dielectric elastomers

    NASA Astrophysics Data System (ADS)

    Chiba, Seiki; Waki, Mikio; Kornbluh, Roy; Pelrine, Ron

    2011-12-01

    Electroactive polymer artificial muscle (EPAM), known collectively as dielectric elastomers in the literature, has been shown to offer unique capabilities as an actuator and is now being developed for a wide variety of generator applications. EPAM has several characteristics that make it potentially well suited for wave, water current, wind, human motion, and other environmental energy harvesting systems including a high energy density allowing for minimal EPAM material quantities, high energy conversion efficiency independent of frequency of operation and non-toxic and low-cost materials not susceptible to corrosion. Experiments have been performed on push-button and heel-mounted generator devices powered by human motion, ocean wave power harvesters mounted on buoys and water turbines. While the power output levels of such demonstration devices is small, the performance of these devices has supported the potential benefits of EPAM. For example, an electrical energy conversion efficiency of over 70% was achieved with small wave heights. The ability of EPAM to produce hydrogen fuel for energy storage was also demonstrated. Because the energy conversion principle of EPAM is capacitive in nature, the performance is largely independent of size and it should eventually be possible to scale up EPAM generators to the megawatt level to address a variety of electrical power needs.

  2. Literature Review on Needs of Upper Limb Prosthesis Users

    PubMed Central

    Cordella, Francesca; Ciancio, Anna Lisa; Sacchetti, Rinaldo; Davalli, Angelo; Cutti, Andrea Giovanni; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out the main critical aspects of the current prosthetic solutions, in terms of users satisfaction and activities of daily living they would like to perform with the prosthetic device. The ultimate goal is to provide design inputs in the prosthetic field and, contemporary, increase user satisfaction rates and reduce device abandonment. A list of requirements for upper limb prostheses is proposed, grounded on the performed analysis on user needs. It wants to (i) provide guidelines for improving the level of acceptability and usefulness of the prosthesis, by accounting for hand functional and technical aspects; (ii) propose a control architecture of PNS-based prosthetic systems able to satisfy the analyzed user wishes; (iii) provide hints for improving the quality of the methods (e.g., questionnaires) adopted for understanding the user satisfaction with their prostheses. PMID:27242413

  3. Gender differences in episodic memory and visual working memory including the effects of age.

    PubMed

    Pauls, Franz; Petermann, Franz; Lepach, Anja Christina

    2013-01-01

    Analysing the relationship between gender and memory, and examining the effects of age on the overall memory-related functioning, are the ongoing goals of psychological research. The present study examined gender and age group differences in episodic memory with respect to the type of task. In addition, these subgroup differences were also analysed in visual working memory. A sample of 366 women and 330 men, aged between 16 and 69 years of age, participated in the current study. Results indicate that women outperformed men on auditory memory tasks, whereas male adolescents and older male adults showed higher level performances on visual episodic and visual working memory measures. However, the size of gender-linked effects varied somewhat across age groups. Furthermore, results partly support a declining performance on episodic memory and visual working memory measures with increasing age. Although age-related losses in episodic memory could not be explained by a decreasing verbal and visuospatial ability with age, women's advantage in auditory episodic memory could be explained by their advantage in verbal ability. Men's higher level visual episodic memory performance was found to result from their advantage in visuospatial ability. Finally, possible methodological, biological, and cognitive explanations for the current findings are discussed.

  4. A Comparative Analysis between GaN-Based Current and Voltage Mode Class-D and E PAs for Communications

    DTIC Science & Technology

    2017-03-01

    power level (5-10W) transmitters. The designs are analyzed and compared with respect to non-idealities such as bondwire effects and input signal duty...Hence, sub-optimum class- E/inverse class-E designs were implemented in this work and compared with respect to reduced duty cycle performance...inverse class E PA achieves 61.5% efficiency for medium power levels (37.7dBm) at 880MHz. The three designed PAs have been compared with respect to

  5. Hierarchical Context Modeling for Video Event Recognition.

    PubMed

    Wang, Xiaoyang; Ji, Qiang

    2016-10-11

    Current video event recognition research remains largely target-centered. For real-world surveillance videos, targetcentered event recognition faces great challenges due to large intra-class target variation, limited image resolution, and poor detection and tracking results. To mitigate these challenges, we introduced a context-augmented video event recognition approach. Specifically, we explicitly capture different types of contexts from three levels including image level, semantic level, and prior level. At the image level, we introduce two types of contextual features including the appearance context features and interaction context features to capture the appearance of context objects and their interactions with the target objects. At the semantic level, we propose a deep model based on deep Boltzmann machine to learn event object representations and their interactions. At the prior level, we utilize two types of prior-level contexts including scene priming and dynamic cueing. Finally, we introduce a hierarchical context model that systematically integrates the contextual information at different levels. Through the hierarchical context model, contexts at different levels jointly contribute to the event recognition. We evaluate the hierarchical context model for event recognition on benchmark surveillance video datasets. Results show that incorporating contexts in each level can improve event recognition performance, and jointly integrating three levels of contexts through our hierarchical model achieves the best performance.

  6. State of Adult Trainee Inflammatory Bowel Disease Education in the United States: A National Survey

    PubMed Central

    Cohen, Benjamin L.; Ha, Christina; Ananthakrishnan, Ashwin N; Rieder, Florian; Bewtra, Meenakshi

    2016-01-01

    Introduction The fundamentals of inflammatory bowel disease (IBD) education begin during gastroenterology (GI) fellowship training. We performed a survey of GI fellowship program directors (PD) and trainees with the aim to further examine the current state of IBD training in the United States. Materials and Methods A 15-question PD survey and 19-question trainee survey was performed using an online platform. Results Surveys were completed by 43/161 (27%) PDs and 160 trainees. All trainee years were equally represented. A significant proportion of trainees was unsure or felt their inpatient (32%) or outpatient (43%) training was inadequate. Only 28% of trainees were satisfied with their current level of IBD exposure during training. Fewer than half the trainees reported comfort in the management of pouch or stoma issues, the pregnant IBD patient, or post-operative management. The proportion of PDs viewing a competency as essential for trainee education strongly correlated with trainee comfort in that area (Pearson’s rho = 0.793, p<0.01). In multivariate logistic regression, monthly IBD didactics was the only variable independently associated with satisfaction with current level of training (OR 4.1, 95% CI 1.9–9.0). Conclusions Over one-third of participating GI trainees did not feel “confident” or “mostly comfortable” with their level of IBD training, with varying comfort regarding different competencies in IBD management. These findings suggest that specific areas of IBD training may require additional focus during training and can provide the basis for the development of an IBD core competency curriculum. PMID:27306068

  7. Cortisol levels in fingernails, neurocognitive performance and clinical variables in euthymic bipolar I disorder.

    PubMed

    Herane-Vives, Andres; Cleare, Anthony J; Chang, Chin-Kuo; de Angel, Valeria; Papadopoulos, Andrew; Fischer, Susanne; Halari, Rozmin; Cheung, Eric Y W; Young, Allan H

    2017-03-27

    Neurocognitive impairment has been found in bipolar patients. Hypercortisolemia is one possible cause but there has been no agreement on this. Previous sampling methods assessed only acute cortisol levels, whereas the association between cortisol and psychopathology might be better understood by investigating chronic levels. Fingernails are a novel method for measuring chronic cortisol concentration (CCC). Here, we measured CCC in euthymic bipolar disorder I (BD-I) patients and healthy controls using fingernails to investigate whether differences in CCC influenced neurocognitive performance. We also investigated whether differences in clinical illness variables influenced CCC in euthymic BD-I patients. A previous study demonstrated neurocognitive impairment in euthymic BD-I patients. The current study included a portion of this sample: 40 BD-I versus 42 matched controls who provided fingernail samples. There was no statistically significant difference in CCC between controls and BD-I (P = .09). Logistic regression analyses revealed that euthymic bipolar I subjects with more than five years of current euthymia had decreased odds of having higher fingernail cortisol concentration (>71.2 pg/mg) compared to those with less than 1.5 years (P = .04). There was no association between CCC and cognitive impairment in all domains before and after adjustment for age and sex. The current evidence suggests CCC is not a trait biomarker in euthymic BD-I (BD-I). Longer periods of stability in affective disorders are associated with lower CCC. Fingernail cortisol does not seem to be implicated in neurocognitive impairment and BD-I. Future studies may investigate CCC in different illness phases of BD-I.

  8. Evidence-Based Supplements for the Enhancement of Athletic Performance.

    PubMed

    Peeling, Peter; Binnie, Martyn J; Goods, Paul S R; Sim, Marc; Burke, Louise M

    2018-03-01

    A strong foundation in physical conditioning and sport-specific experience, in addition to a bespoke and periodized training and nutrition program, are essential for athlete development. Once these underpinning factors are accounted for, and the athlete reaches a training maturity and competition level where marginal gains determine success, a role may exist for the use of evidence-based performance supplements. However, it is important that any decisions surrounding performance supplements are made in consideration of robust information that suggests the use of a product is safe, legal, and effective. The following review focuses on the current evidence-base for a number of common (and emerging) performance supplements used in sport. The supplements discussed here are separated into three categories based on the level of evidence supporting their use for enhancing sports performance: (1) established (caffeine, creatine, nitrate, beta-alanine, bicarbonate); (2) equivocal (citrate, phosphate, carnitine); and (3) developing. Within each section, the relevant performance type, the potential mechanisms of action, and the most common protocols used in the supplement dosing schedule are summarized.

  9. Static performance of vectoring/reversing non-axisymmetric nozzles

    NASA Technical Reports Server (NTRS)

    Willard, C. M.; Capone, F. J.; Konarski, M.; Stevens, H. L.

    1977-01-01

    An experimental program sponsored by the Air Force Flight Dynamics Laboratory is currently in progress to determine the internal and installed performance characteristics of five different thrust vectoring/reversing non-axisymmetric nozzle concepts for tactical fighter aircraft applications. Internal performance characteristics for the five non-axisymmetric nozzles and an advanced technology axisymmetric baseline nozzle were determined in static tests conducted in January 1977 at the NASA-Langley Research Center. The non-axisymmetric nozzle models were tested at thrust deflection angles of up to 30 degrees from horizontal at throat areas associated with both dry and afterburning power. In addition, dry power reverse thrust geometries were tested for three of the concepts. The best designs demonstrated internal performance levels essentially equivalent to the baseline axisymmetric nozzle at unvectored conditions. The best designs also gave minimum performance losses due to vectoring, and reverse thrust levels up to 50% of maximum dry power forward thrust. The installed performance characteristics will be established based on wind tunnel testing to be conducted at Arnold Engineering Development Center in the fall of 1977.

  10. Preliminary normative data on the BORB for children aged 3-8.

    PubMed

    Brunsdon, Ruth; Joy, Pamela; Patten, Erin; Burton, Karen

    2018-05-09

    The Birmingham Object Recognition Battery (BORB) is a theoretically based test battery that is used in adult cognitive neuropsychology in research and for clinical assessment. It allows a detailed analysis of underlying impairments in individuals with brain injury who have visual object recognition difficulties. The BORB's usefulness in pediatrics is supported by numerous research studies. However, there is no published normative data for children, making clinical use of the test difficult. The aim of this brief report is to publish some preliminary normative data in 70 children aged between 3 and 8 years to assist both researchers and clinicians with interpretation of test scores. Results indicate that children's performance on individual BORB subtests varies according to task demands and age. For some subtests there is improvement in performance with increasing age. However, very young children (age 3-4 years) perform at adult levels on some subtests, or alternatively on other subtests they perform at the level of chance. The current paper supports the need for pediatric data for the BORB due to large normal individual variation in performance and varying age-related performance on individual BORB subtests.

  11. High-Bandwidth Tactical-Network Data Analysis in a High-Performance-Computing (HPC) Environment: Packet-Level Analysis

    DTIC Science & Technology

    2015-09-01

    with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS . 1...UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS (ES) Technical and Project Engineering, LLC QED Systems, LLC Alexandria, VA...AND ADDRESS (ES) US Army Research Laboratory ATTN: RDRL-CIH-C Aberdeen Proving Ground, MD 21005 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR

  12. Multi-Model Validation in the Chesapeake Bay Region During Frontier Sentinel 2010

    DTIC Science & Technology

    2012-09-28

    which a 72-hr forecast took approximately 1 hr. Identical runs were performed on the DoD Supercomputing Resources Center (DSRC) host “ DaVinci ” at the...performance Navy DSRC host DaVinci . Products of water level and horizontal current maps as well as station time series, identical to those produced by the...forecast meteorological fields. The NCOM simulations were run daily on 128 CPUs at the Navy DSRC host DaVinci and required approximately 5 hrs of wall

  13. Analytical investigation of thermal barrier coatings on advanced power generation gas turbines

    NASA Technical Reports Server (NTRS)

    Amos, D. J.

    1977-01-01

    An analytical investigation of present and advanced gas turbine power generation cycles incorporating thermal barrier turbine component coatings was performed. Approximately 50 parametric points considering simple, recuperated, and combined cycles (including gasification) with gas turbine inlet temperatures from current levels through 1644K (2500 F) were evaluated. The results indicated that thermal barriers would be an attractive means to improve performance and reduce cost of electricity for these cycles. A recommended thermal barrier development program has been defined.

  14. The Space Station air revitalization subsystem design concept

    NASA Technical Reports Server (NTRS)

    Ray, C. D.; Ogle, K. Y.; Tipps, R. W.; Carrasquillo, R. L.; Wieland, P.

    1987-01-01

    The current status of the Space Station (SS) Environmental Control and Life Support System (ECLSS) Air Revitalization Subsystem (ARS) design is outlined. ARS performance requirements are provided, along with subsystem options for each ARS function and selected evaluations of the relative merits of each subsystem. Detailed computer models that have been developed to analyze individual subsystem performance capabilities are also discussed. A summary of ARS subsystem level testing planned and completed by NASA Marshall Space Flight Center (MSFC) is given.

  15. State-of-the-Art for Small Satellite Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Parker, Khary I.

    2016-01-01

    SmallSats are a low cost access to space with an increasing need for propulsion systems. NASA, and other organizations, will be using SmallSats that require propulsion systems to: a) Conduct high quality near and far reaching on-orbit research and b) Perform technology demonstrations. Increasing call for high reliability and high performing for SmallSat components. Many SmallSat propulsion technologies are currently under development: a) Systems at various levels of maturity and b) Wide variety of systems for many mission applications.

  16. An LED solar simulator for student labs

    NASA Astrophysics Data System (ADS)

    González, Manuel I.

    2017-05-01

    Measuring voltage-current and voltage-power curves of a photovoltaic module is a nice experiment for high school and undergraduate students. In labs where real sunlight is not available this experiment requires a solar simulator. A prototype of a simulator using LED lamps has been manufactured and tested, and a comparison with classical halogen simulators has been performed. It is found that LED light offers lower levels of irradiance, but much better performance in terms of module output for a given irradiance.

  17. Vented Versus Unvented Chest Seals for Treatment of Pneumothorax and Prevention of Tension Pneumothorax in a Swine Model

    DTIC Science & Technology

    2013-07-01

    person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control ...were obtained. Data Analysis Data are expressed as mean T SEM. Between- group anal- ysis (Halo vs. Bolin) was performed using two-way repeated...measures analysis of variance. Bonferroni post test was used to compare replicate means at each PTx level. Within- group (treat- ment) analysis was performed

  18. Variability in the Use of Simulation for Procedural Training in Radiology Residency: Opportunities for Improvement.

    PubMed

    Matalon, Shanna A; Chikarmane, Sona A; Yeh, Eren D; Smith, Stacy E; Mayo-Smith, William W; Giess, Catherine S

    2018-03-19

    Increased attention to quality and safety has led to a re-evaluation of the classic apprenticeship model for procedural training. Many have proposed simulation as a supplementary teaching tool. The purpose of this study was to assess radiology resident exposure to procedural training and procedural simulation. An IRB-exempt online survey was distributed to current radiology residents in the United States by e-mail. Survey results were summarized using frequency and percentages. Chi-square tests were used for statistical analysis where appropriate. A total of 353 current residents completed the survey. 37% (n = 129/353) of respondents had never used procedure simulation. Of the residents who had used simulation, most did not do so until after having already performed procedures on patients (59%, n = 132/223). The presence of a dedicated simulation center was reported by over half of residents (56%, n = 196/353) and was associated with prior simulation experience (P = 0.007). Residents who had not had procedural simulation were somewhat likely or highly likely (3 and 4 on a 4-point Likert-scale) to participate if it were available (81%, n = 104/129). Simulation training was associated with higher comfort levels in performing procedures (P < 0.001). Although procedural simulation training is associated with higher comfort levels when performing procedures, there is variable use in radiology resident training and its use is not currently optimized. Given the increased emphasis on patient safety, these results suggest the need to increase procedural simulation use during residency, including an earlier introduction to simulation before patient exposure. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Can hospital dashboards provide visibility of information from bedside to board? A case study approach.

    PubMed

    Pace, Adriana; Buttigieg, Sandra C

    2017-04-10

    Purpose The purpose of this paper is to analyse hospital dashboards' visibility of information at different management levels to improve quality and performance in an acute general hospital. Design/methodology/approach Data were generated via 21 semi-structured interviews across different management levels. Findings All management levels had greater visibility of information, could make informed decisions, and registered performance improvement. Specifically, waiting time improved, however since introduction of hospital dashboards was work-in-progress at time of study, managers could not record improvement in terms of cost reductions, clinical effectiveness, patient safety and patient satisfaction. Different managerial levels had different visibility with top management having the greatest. Research limitations/implications In single case studies, where only one context is used, the findings cannot be reproduced in different contexts; even though most of the results could be matched with the current literature. Practical implications The need to have balanced key performance indicators that take into account other facets of improvements, apart from time, has been emphasised. Furthermore, if middle and departmental managers have greater visibility, this would allow them to work towards a strategic fit between the departments that they manage with the rest of the hospital. Originality/value There is scant literature regarding performance dashboards' enhancement of visibility of information at different management levels. Furthermore, according to the authors' knowledge, no other paper has tried to identify and discuss the different levels of information, which should be visible from bedside to board namely to management, clinicians and public.

  20. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    NASA Astrophysics Data System (ADS)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-09-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  1. Transcranial direct current stimulation combined with upper limb functional training in children with spastic, hemiparetic cerebral palsy: study protocol for a randomized controlled trial.

    PubMed

    Moura, Renata Calhes Franco; Santos, Cibele Almeida; Grecco, Luanda André Collange; Lazzari, Roberta Delasta; Dumont, Arislander Jonathan Lopes; Duarte, Natalia Carvalho de Almeida; Braun, Luiz Alfredo; Lopes, Jamile Benite Palma; Santos, Ligia Abram Dos; Rodrigues, Eliane Lopes Souza; Albertini, Giorgio; Cimolin, Veronica; Galli, Manuela; Oliveira, Claudia Santos

    2016-08-17

    The aim of the proposed study is to perform a comparative analysis of functional training effects for the paretic upper limb with and without transcranial direct current stimulation over the primary motor cortex in children with spastic hemiparetic cerebral palsy. The sample will comprise 34 individuals with spastic hemiparetic cerebral palsy, 6 to 16 years old, classified at level I, II, or III of the Manual Ability Classification System. Participants will be randomly allocated to two groups: (1) functional training of the paretic upper limb combined with anodic transcranial stimulation; (2) functional training of the paretic upper limb combined with sham transcranial stimulation. Evaluation will involve three-dimensional movement analysis and electromyography using the SMART-D 140® system (BTS Engineering) and the FREEEMG® system (BTS Engineering), the Quality of Upper Extremity Skills Test, to assess functional mobility, the Portable Device and Ashworth Scale, to measure movement resistance and spasticity, and the Pediatric Evaluation of Disability Inventory, to evaluate performance. Functional reach training of the paretic upper limb will include a range of manual activities using educational toys associated with an induced constraint of the non-paretic limb during the training. Training will be performed in five weekly 20-minute sessions for two weeks. Transcranial stimulation over the primary motor cortex will be performed during the training sessions at an intensity of 1 mA. Findings will be analyzed statistically considering a 5 % significance level (P ≤ 0.05). This paper presents a detailed description of a prospective, randomized, controlled, double-blind, clinical trial designed to demonstrate the effects of combining transcranial direct current stimulation over the primary motor cortex and functional training of the paretic limb in children with cerebral palsy classified at level I, II, or III of the Manual Ability Classification System. The results will be published and evidence found may contribute to the use of transcranial stimulation for this population. ReBEC RBR-6V4Y3K . Registered on 11 February 2015.

  2. Modeling level change in Lake Urmia using hybrid artificial intelligence approaches

    NASA Astrophysics Data System (ADS)

    Esbati, M.; Ahmadieh Khanesar, M.; Shahzadi, Ali

    2017-06-01

    The investigation of water level fluctuations in lakes for protecting them regarding the importance of these water complexes in national and regional scales has found a special place among countries in recent years. The importance of the prediction of water level balance in Lake Urmia is necessary due to several-meter fluctuations in the last decade which help the prevention from possible future losses. For this purpose, in this paper, the performance of adaptive neuro-fuzzy inference system (ANFIS) for predicting the lake water level balance has been studied. In addition, for the training of the adaptive neuro-fuzzy inference system, particle swarm optimization (PSO) and hybrid backpropagation-recursive least square method algorithm have been used. Moreover, a hybrid method based on particle swarm optimization and recursive least square (PSO-RLS) training algorithm for the training of ANFIS structure is introduced. In order to have a more fare comparison, hybrid particle swarm optimization and gradient descent are also applied. The models have been trained, tested, and validated based on lake level data between 1991 and 2014. For performance evaluation, a comparison is made between these methods. Numerical results obtained show that the proposed methods with a reasonable error have a good performance in water level balance prediction. It is also clear that with continuing the current trend, Lake Urmia will experience more drop in the water level balance in the upcoming years.

  3. Evaluation of a pulsed quasi-steady MPD thruster and associated subsystems

    NASA Technical Reports Server (NTRS)

    Lien, H.; Garrison, R. L.; Libby, D. R.

    1972-01-01

    The performance of quasi-steady magnetoplasmadynamic (MPD) thrusters at high power levels is discussed. An axisymmetric configuration is used for the MPD thruster, with various cathode and anode sizes, over a wide range of experimental conditions. Thrust is determined from impulse measurements with current waveforms, while instantaneous measurements are made for all other variables. It is demonstrated that the thrust produced has a predominately self-magnetic origin and is directly proportional to the square of the current. The complete set of impulse measurement data is presented.

  4. Leap Frog Digital Sensors and Definition, Integration & Testing FY 2003 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitzler, Wayne D.; Ouderkirk, Steven J.; Shoemaker, Steven V.

    2003-12-31

    The objective of Leap Frog is to develop a comprehensive security tool that is transparent to the user community and more effective than current methods for preventing and detecting security compromises of critical physical and digital assets. Current security tools intrude on the people that interact with these critical assets by requiring them to perform additional functions or having additional visible sensors. Leap Frog takes security to the next level by being more effective and reducing the adverse impact on the people interacting with protected assets.

  5. Genetic tool development and systemic regulation in biosynthetic technology.

    PubMed

    Dai, Zhongxue; Zhang, Shangjie; Yang, Qiao; Zhang, Wenming; Qian, Xiujuan; Dong, Weiliang; Jiang, Min; Xin, Fengxue

    2018-01-01

    With the increased development in research, innovation, and policy interest in recent years, biosynthetic technology has developed rapidly, which combines engineering, electronics, computer science, mathematics, and other disciplines based on classical genetic engineering and metabolic engineering. It gives a wider perspective and a deeper level to perceive the nature of life via cell mechanism, regulatory networks, or biological evolution. Currently, synthetic biology has made great breakthrough in energy, chemical industry, and medicine industries, particularly in the programmable genetic control at multiple levels of regulation to perform designed goals. In this review, the most advanced and comprehensive developments achieved in biosynthetic technology were represented, including genetic engineering as well as synthetic genomics. In addition, the superiority together with the limitations of the current genome-editing tools were summarized.

  6. RF assisted switching in magnetic Josephson junctions

    NASA Astrophysics Data System (ADS)

    Caruso, R.; Massarotti, D.; Bolginov, V. V.; Ben Hamida, A.; Karelina, L. N.; Miano, A.; Vernik, I. V.; Tafuri, F.; Ryazanov, V. V.; Mukhanov, O. A.; Pepe, G. P.

    2018-04-01

    We test the effect of an external RF field on the switching processes of magnetic Josephson junctions (MJJs) suitable for the realization of fast, scalable cryogenic memories compatible with Single Flux Quantum logic. We show that the combined application of microwaves and magnetic field pulses can improve the performances of the device, increasing the separation between the critical current levels corresponding to logical "0" and "1." The enhancement of the current level separation can be as high as 80% using an optimal set of parameters. We demonstrate that external RF fields can be used as an additional tool to manipulate the memory states, and we expect that this approach may lead to the development of new methods of selecting MJJs and manipulating their states in memory arrays for various applications.

  7. Assessing the clinical benefit of nuclear matrix protein 22 in the surveillance of patients with nonmuscle-invasive bladder cancer and negative cytology: a decision-curve analysis.

    PubMed

    Shariat, Shahrokh F; Savage, Caroline; Chromecki, Thomas F; Sun, Maxine; Scherr, Douglas S; Lee, Richard K; Lughezzani, Giovanni; Remzi, Mesut; Marberger, Michael J; Karakiewicz, Pierre I; Vickers, Andrew J

    2011-07-01

    Several studies have demonstrated that abnormal levels of nuclear matrix protein 22 (NMP22) are associated with bladder cancer and have led to the approval of NMP22 as a urinary biomarker by the US Food and Drug Administration. Nonetheless, the clinical significance of NMP22 remains unclear. The objective of this study was to use decision analysis to determine whether NMP22 improves medical decision-making. The current study included 2222 patients who had a history of nonmuscle-invasive bladder cancer and current negative cytology. The authors developed models to predict cancer recurrence or progression to muscle-invasive disease using voided NMP22 levels, cystoscopy, age, and sex. Clinical net benefit was calculated by summing the benefits (true-positives), subtracting the harms (false-positives), and weighting these values by the threshold probability at which a patient or clinician would opt for cytoscopy. After cystoscopy, 581 patients (26%) had cancer identified. The NMP22 level was associated significantly with bladder cancer recurrence and progression (P < .001 for both). The use of NMP22 in a model with age and sex was associated with better patient outcomes than performing cystoscopy on everyone and produced threshold probabilities > 8% for recurrence and > 3% for progression. Only offering cystoscopy to those who had a risk > 15% reduced the number of cystoscopies by 229 while missing only 25 cancer recurrences per 1000 men with negative cytology. The current study was limited by its multicenter design. For clinicians who would perform a cystoscopy at a threshold of 5% for recurrence or 1% for progression, NMP22 did not aid clinical decision-making. For less risk-averse clinicians who would only perform a cystoscopy at a threshold probability >thinsp;8% for recurrence or > 3% for progression, NMP22 helped to indicate which patients required cystoscopy and which could be spared this procedure. Copyright © 2011 American Cancer Society.

  8. Sex differences in visuospatial abilities persist during induced hypogonadism

    PubMed Central

    Guerrieri, Gioia M.; Wakim, Paul G.; Keenan, P.A.; Schenkel, Linda A; Berlin, Kate; Gibson, Carolyn J.; Rubinow, David R.; Schmidt, Peter J.

    2016-01-01

    Background Despite well-established sex differences in the performance on tests of several cognitive domains (e.g., visuospatial ability), few studies in humans have evaluated if these sex differences are evident both in the presence of circulating sex hormones and during sex steroid hormonal suppression. Sex differences identified in the relative absence of circulating levels of estradiol and testosterone suggest that differences in brain structure or function exist independent of current hormonal environment and are more likely a reflection of differing developmental exposures and/or genetic substrates. Objective To evaluate cognitive performance in healthy eugonadal men and women before and again during GnRH agonist-induced hypogonadism. Methods Men (n = 16) and women (n = 15) without medical or psychiatric illness were matched for IQ. Cognitive tests were performed at baseline (when eugonadal) and after 68 weeks of GnRH agonist-induced gonadal suppression. The test batteries included measures of verbal and spatial memory, spatial ability, verbal fluency, motor speed/dexterity, and attention/concentration. Data were analyzed using repeated-measures models. Results During both eugonadism and hypogonadism, men performed significantly better than women on several measures of visuospatial performance including mental rotation, line orientation, Money Road Map, Porteus maze, and complex figure drawing. Although some test performances showed an effect of hormone treatment, the majority of these differences reflected an improved performance during hypogonadism compared with baseline (and probably reflected practice effects). Conclusion The well-documented male advantage in visuospatial performance, which we observed during eugonadal conditions, was maintained in the context of short-term suppression of gonadal function in both men and women. These findings suggest that, in humans, sex differences in visuospatial performance are not merely dependent on differences in the current circulating sex steroid environment. Thus sex differences in visuospatial performance in adulthood could reflect early developmental effects of sex steroid exposure or other environmental exposures differing across the sexes as our data confirm that these differences are independent of circulating estradiol or testosterone levels in men and women. PMID:26719236

  9. Sex differences in visuospatial abilities persist during induced hypogonadism.

    PubMed

    Guerrieri, Gioia M; Wakim, Paul G; Keenan, P A; Schenkel, Linda A; Berlin, Kate; Gibson, Carolyn J; Rubinow, David R; Schmidt, Peter J

    2016-01-29

    Despite well-established sex differences in the performance on tests of several cognitive domains (e.g., visuospatial ability), few studies in humans have evaluated if these sex differences are evident both in the presence of circulating sex hormones and during sex steroid hormonal suppression. Sex differences identified in the relative absence of circulating levels of estradiol and testosterone suggest that differences in brain structure or function exist independent of current hormonal environment and are more likely a reflection of differing developmental exposures and/or genetic substrates. To evaluate cognitive performance in healthy eugonadal men and women before and again during GnRH agonist-induced hypogonadism. Men (n=16) and women (n=15) without medical or psychiatric illness were matched for IQ. Cognitive tests were performed at baseline (when eugonadal) and after 6-8 weeks of GnRH agonist-induced gonadal suppression. The test batteries included measures of verbal and spatial memory, spatial ability, verbal fluency, motor speed/dexterity, and attention/concentration. Data were analyzed using repeated-measures models. During both eugonadism and hypogonadism, men performed significantly better than women on several measures of visuospatial performance including mental rotation, line orientation, Money Road Map, Porteus maze, and complex figure drawing. Although some test performances showed an effect of hormone treatment, the majority of these differences reflected an improved performance during hypogonadism compared with baseline (and probably reflected practice effects). The well-documented male advantage in visuospatial performance, which we observed during eugonadal conditions, was maintained in the context of short-term suppression of gonadal function in both men and women. These findings suggest that, in humans, sex differences in visuospatial performance are not merely dependent on differences in the current circulating sex steroid environment. Thus sex differences in visuospatial performance in adulthood could reflect early developmental effects of sex steroid exposure or other environmental exposures differing across the sexes as our data confirm that these differences are independent of circulating estradiol or testosterone levels in men and women. Published by Elsevier Ltd.

  10. Chiropractic treatment and the enhancement of sport performance: a narrative literature review

    PubMed Central

    Miners, Andrew L.

    2010-01-01

    A literature search and narrative review was carried out with the intent of determining the current level of knowledge regarding the chiropractic treatment of athletes for the purpose of sport performance enhancement. Of the fifty-nine relevant articles retrieved, only 7 articles of variable quality were obtained which specifically investigated/discussed chiropractic treatment and its involvement in sport performance enhancement. The role of the chiropractor in sport, unsubstantiated claims of performance enhancement, theories of how chiropractic treatment may influence sport performance, and the available evidence for the benefit of chiropractic treatment on sport performance are reviewed and discussed. Areas and directions for future studies are postulated. At this time there is insufficient evidence to convincingly support the notion that treatment provided by chiropractors can directly improve sport performance. PMID:21120012

  11. Current evidence demonstrates similar effects of kilohertz-frequency and low-frequency current on quadriceps evoked torque and discomfort in healthy individuals: a systematic review with meta-analysis.

    PubMed

    da Silva, Vinicius Zacarias Maldaner; Durigan, João Luiz Quaglioti; Arena, Ross; de Noronha, Marcos; Gurney, Burke; Cipriano, Gerson

    2015-01-01

    Neuromuscular electrical stimulation (NMES) is widely utilized to enhance muscle performance. However, the optimal NMES waveform with respect to treatment effect has not been established. To investigate the effects of kilohertz-frequency alternating current (KFAC) and low-frequency pulsed current (PC) on quadriceps evoked torque and self-reported discomfort. PubMed, The Cochrane Library, EMBASE, MEDLINE, Physiotherapy Evidence Database (PEDro), SinoMed, ISI Web of Knowledge, and CINAHL were searched for randomized controlled trials (RCTs) and quasi-randomized controlled trials (QRCTs). Two reviewers independently selected potential studies according to the inclusion criteria, extracted data, and assessed methodological quality. Studies were eligible if they compared KFAC versus PC interventions. Studies that included outcome measures for percentage of maximal isometric voluntary contraction (%MIVC) torque and self-reported discomfort level were eligible for evaluation. Seven studies involving 127 individuals were included. The methodological quality of eligible trials was moderate, with a mean of 5 on the 10-point PEDro scale. Overall, PC was no better than KFAC in terms of evoked torque and there was no difference in self-reported discomfort level. KFAC and PC have similar effects on quadriceps evoked torque and self-reported discomfort level in healthy individuals. The small number and overall methodological quality of currently available studies included in this meta-analysis indicate that new RCTs are needed to better determine optimal NMES treatment parameters.

  12. Current recommended 25-hydroxyvitamin D targets for chronic kidney disease management may be too low.

    PubMed

    Ennis, Jennifer L; Worcester, Elaine M; Coe, Fredric L; Sprague, Stuart M

    2016-02-01

    It is uncertain whether increasing 25-hydroxyvitamin D (25-D) levels in chronic kidney disease (CKD) patients above those recommended by current guidelines result in progressive amelioration of secondary hyperparathyroidism. Our objective was to identify a potential therapeutic 25-D target which optimally lowers plasma parathyroid hormone (PTH) without producing excessive hypercalcemia or hyperphosphatemia in CKD. We performed a cross-sectional analysis of 14,289 unselected stage 1-5 CKD patients from US primary care and nephrology practices utilizing a laboratory-based CKD clinical decision support service between September 2008 and May 2012. Estimated glomerular filtration rate (eGFR), plasma PTH, and serum 25-D, calcium, and phosphorus results were analyzed. In CKD stages 3-5, progressively higher 25-D pentiles contained progressively lower mean PTH levels. Regression analysis of log PTH on 25-D was significant in all CKD stages with no evidence of a decreasing effect of 25-D to lower PTH until 25-D levels of 42-48 ng/ml. Progressively higher 25-D concentrations were not associated with increased rates of hypercalcemia or hyperphosphatemia. We found evidence for an optimal level of 25-D above which suppression of PTH progressively diminishes. This level is more than twice that currently recommended for the general population. We found no association between these higher 25-D levels and hyperphosphatemia or hypercalcemia. Additional prospective trials seem appropriate to test the idea that 25-D levels around 40-50 ng/ml could be a safe and effective treatment target for secondary hyperparathyroidism in CKD.

  13. A 10-kW series resonant converter design, transistor characterization, and base-drive optimization

    NASA Technical Reports Server (NTRS)

    Robson, R. R.; Hancock, D. J.

    1982-01-01

    The development, components, and performance of a transistor-based 10 kW series resonant converter for use in resonant circuits in space applications is described. The transistors serve to switch on the converter current, which has a half-sinusoid waveform when the transistor is in saturation. The goal of the program was to handle an input-output voltage range of 230-270 Vdc, an output voltage range of 200-500 Vdc, and a current limit range of 0-20 A. Testing procedures for the D60T and D7ST transistors are outlined and base drive waveforms are presented. The total device dissipation was minimized and found to be independent of the regenerative feedback ratio at lower current levels. Dissipation was set at within 10% and rise times were found to be acceptable. The finished unit displayed a 91% efficiency at full power levels of 500 V and 20 A and 93.7% at 500 V and 10 A.

  14. Leakage current and capacitance characteristics of Si/SiO2/Si single-barrier varactor

    NASA Astrophysics Data System (ADS)

    Mamor, M.; Fu, Y.; Nur, O.; Willander, M.; Bengtsson, S.

    We investigate, both experimentally and theoretically, current and capacitance (I-V/C-V) characteristics and the device performance of Si/SiO2/Si single-barrier varactor diodes (SBVs). Two diodes were fabricated with different SiO2 layer thicknesses using the state-of-the-art wafer bonding technique. The devices have very low leakage currents (about 5×10-2 and 1.8×10-2 mA/mm2) and intrinsic capacitance levels of typically 1.5 and 50 nF/mm2 for diodes with 5-nm and 20-nm oxide layers, respectively. With the present device physical parameters (25-mm2 device area, 760-μm modulation layer thickness and 1015-cm-3 doping level), the estimated cut-off frequency is about 5×107 Hz. With the physical parameters of the present existing III-V triplers, the cut-off frequency of our Si-based SBV can be as high as 0.5 THz.

  15. Deep-levels in gallium arsenide for device applications

    NASA Astrophysics Data System (ADS)

    McManis, Joseph Edward

    Defects in semiconductors have been studied for over 40 years as a diagnostic of the quality of crystal growth. In this thesis, we investigate GaAs deep-levels specifically intended for devices. This thesis summarizes our efforts to characterize the near-infrared photoluminescence from deep-levels, study optical transitions via absorption, and fabricate and characterize deep-level light-emitting diodes (LEDs). This thesis also describes the first tunnel diodes which explicitly make use of GaAs deep-levels. Photoluminescence measurements of GaAs deep-levels showed a broad peak around a wavelength extending from 1.0--1.7 mum, which includes important wavelengths for fiber-optic communications (1.3--1.55 mum). Transmission measurements show the new result that very little of the radiative emission is self-absorbed. We measured the deep-level photoluminescence at several temperatures. We are also the first to report the internal quantum efficiency associated with the deep-level transitions. We have fabricated LEDs that, utilize the optical transitions of GaAs deep-levels. The electroluminescence spectra showed a broad peak from 1.0--1.7 mum at low currents, but the spectrum exhibited a blue-shift as the current was increased. To improve device performance, we designed an AlGaAs layer into the structure of the LEDs. The AlGaAs barrier layer acts as a resistive barrier so that the holes in the p-GaAs layer are swept away from underneath the gold p-contact. The AlGaAs layer also reduces the blue-shift by acting as a potential barrier so that only higher-energy holes are injected. We found that the LEDs with AlGaAs were brighter at long wavelengths, which was a significant improvement. Photoluminescence measurements show that the spectral blue-shift is not due to sample heating. We have developed a new physical model to explain the blue-shift: it is caused by Coloumb charging of the deep-centers. We have achieved the first tunnel diodes with which specifically utilize deep-levels in low-temperature-grown (LTG) GaAs. Our devices show the largest ever peak current density in a GaAs tunnel diode at room temperature. Our devices also show significant room-temperature peak-to-valley current ratios. The shape of the current-voltage characteristic and the properties of the optical emission enable us to determine the peak and valley transport mechanisms.

  16. Effect of plasma arc welding variables on fusion zone grain size and hardness of AISI 321 austenitic stainless steel

    NASA Astrophysics Data System (ADS)

    Kondapalli, S. P.

    2017-12-01

    In the present work, pulsed current microplasma arc welding is carried out on AISI 321 austenitic stainless steel of 0.3 mm thickness. Peak current, Base current, Pulse rate and Pulse width are chosen as the input variables, whereas grain size and hardness are considered as output responses. Response surface method is adopted by using Box-Behnken Design, and in total 27 experiments are performed. Empirical relation between input and output response is developed using statistical software and analysis of variance (ANOVA) at 95% confidence level to check the adequacy. The main effect and interaction effect of input variables on output response are also studied.

  17. High-power single spatial mode AlGaAs channeled-substrate-planar semiconductor diode lasers for spaceborne communications

    NASA Technical Reports Server (NTRS)

    Connolly, J. C.; Carlin, D. B.; Ettenberg, M.

    1989-01-01

    A high power single spatial mode channeled substrate planar AlGaAs semiconductor diode laser was developed. The emission wavelength was optimized at 860 to 880 nm. The operating characteristics (power current, single spatial mode behavior, far field radiation patterns, and spectral behavior) and results of computer modeling studies on the performance of the laser are discussed. Reliability assessment at high output levels is included. Performance results on a new type of channeled substrate planar diode laser incorporating current blocking layers, grown by metalorganic chemical vapor deposition, to more effectively focus the operational current to the lasing region was demonstrated. The optoelectronic behavior and fabrication procedures for this new diode laser are discussed. The highlights include single spatial mode devices with up to 160 mW output at 8600 A, and quantum efficiencies of 70 percent (1 W/amp) with demonstrated operating lifetimes of 10,000 h at 50 mW.

  18. Intercepting a moving target: On-line or model-based control?

    PubMed

    Zhao, Huaiyong; Warren, William H

    2017-05-01

    When walking to intercept a moving target, people take an interception path that appears to anticipate the target's trajectory. According to the constant bearing strategy, the observer holds the bearing direction of the target constant based on current visual information, consistent with on-line control. Alternatively, the interception path might be based on an internal model of the target's motion, known as model-based control. To investigate these two accounts, participants walked to intercept a moving target in a virtual environment. We degraded the target's visibility by blurring the target to varying degrees in the midst of a trial, in order to influence its perceived speed and position. Reduced levels of visibility progressively impaired interception accuracy and precision; total occlusion impaired performance most and yielded nonadaptive heading adjustments. Thus, performance strongly depended on current visual information and deteriorated qualitatively when it was withdrawn. The results imply that locomotor interception is normally guided by current information rather than an internal model of target motion, consistent with on-line control.

  19. Implementation of nitrogen-doped titanium-tungsten tunable heater in phase change random access memory and its effects on device performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Chun Chia; Zhao, Rong, E-mail: zhao-rong@sutd.edu.sg; Chong, Tow Chong

    2014-10-13

    Nitrogen-doped titanium-tungsten (N-TiW) was proposed as a tunable heater in Phase Change Random Access Memory (PCRAM). By tuning N-TiW's material properties through doping, the heater can be tailored to optimize the access speed and programming current of PCRAM. Experiments reveal that N-TiW's resistivity increases and thermal conductivity decreases with increasing nitrogen-doping ratio, and N-TiW devices displayed (∼33% to ∼55%) reduced programming currents. However, there is a tradeoff between the current and speed for heater-based PCRAM. Analysis of devices with different N-TiW heaters shows that N-TiW doping levels could be optimized to enable low RESET currents and fast access speeds.

  20. Effect of fed-batch vs. continuous mode of operation on microbial fuel cell performance treating biorefinery wastewater

    DOE PAGES

    Pannell, Tyler C.; Goud, R. Kannaiah; Schell, Daniel J.; ...

    2016-05-01

    Bioelectrochemical systems have been shown to treat low-value biorefinery streams while recovering energy, however, low current densities and anode conversion efficiencies (ACE) limit their application. A bioanode was developed via enrichment of electroactive biofilm under fed-batch and continuous feeding conditions using corn stover-derived waste stream. The continuously-fed MFC exhibited a current density of 5.8±0.06 A/m 2 and an ACE of 39%±4. The fed-batch MFC achieved a similar current density and an ACE of 19.2%, however, its performance dropped after 36 days of operation to 1.1 A/m 2 and 0.5%, respectively. In comparison, the ACE of the continuously-fed MFC remained stablemore » achieving an ACE of 30% ± 3 after 48 days of operation. An MFC treating a biorefinery stream post fuel separation achieved a current density of 10.7±0.1 A/m 2 and an ACE of 57% ± 9 at an organic loading of 12.5 g COD/L-day. Characterization of the microbial communities indicate higher abundance of Firmicutes and Proteobacteria and lower abundance of Bacteriodetes and a higher level of Geobacter spp. (1.4% vs. 0.2%) in continuously-fed MFC vs. fed-batch MFC. Finally, the results demonstrate that limiting substrate to the equivalent maximum current that the anode can generate, maintains MFC performance over a long term for high strength wastewaters, such as those generated in the biorefinery.« less

Top