A beam current density monitor for intense electron beams
NASA Astrophysics Data System (ADS)
Fiorito, R. B.; Raleigh, M.; Seltzer, S. M.
1983-12-01
The authors describe a new type of electric probe for mapping the radial current density profile of high-energy, high current electron beams. The idea of developing an electrically sensitive probe for these conditions was originally suggested to one of the authors during a year's visit to the Lawrence Livermore National Laboratory. The resulting probe is intended for use on the Experimental Test Accelerator (ETA) and the Advanced Test Accelerator at that laboratory. This report discusses in detail: the mechanical design, the electrical response, and temperature effects, as they pertain to the electric probe, and describe the first experimental results obtained using this probe on ETA.
Rifai, Damhuji; Abdalla, Ahmed N.; Ali, Kharudin; Razali, Ramdan
2016-01-01
Non-destructive eddy current testing (ECT) is widely used to examine structural defects in ferromagnetic pipe in the oil and gas industry. Implementation of giant magnetoresistance (GMR) sensors as magnetic field sensors to detect the changes of magnetic field continuity have increased the sensitivity of eddy current techniques in detecting the material defect profile. However, not many researchers have described in detail the structure and issues of GMR sensors and their application in eddy current techniques for nondestructive testing. This paper will describe the implementation of GMR sensors in non-destructive testing eddy current testing. The first part of this paper will describe the structure and principles of GMR sensors. The second part outlines the principles and types of eddy current testing probe that have been studied and developed by previous researchers. The influence of various parameters on the GMR measurement and a factor affecting in eddy current testing will be described in detail in the third part of this paper. Finally, this paper will discuss the limitations of coil probe and compensation techniques that researchers have applied in eddy current testing probes. A comprehensive review of previous studies on the application of GMR sensors in non-destructive eddy current testing also be given at the end of this paper. PMID:26927123
Rifai, Damhuji; Abdalla, Ahmed N; Ali, Kharudin; Razali, Ramdan
2016-02-26
Non-destructive eddy current testing (ECT) is widely used to examine structural defects in ferromagnetic pipe in the oil and gas industry. Implementation of giant magnetoresistance (GMR) sensors as magnetic field sensors to detect the changes of magnetic field continuity have increased the sensitivity of eddy current techniques in detecting the material defect profile. However, not many researchers have described in detail the structure and issues of GMR sensors and their application in eddy current techniques for nondestructive testing. This paper will describe the implementation of GMR sensors in non-destructive testing eddy current testing. The first part of this paper will describe the structure and principles of GMR sensors. The second part outlines the principles and types of eddy current testing probe that have been studied and developed by previous researchers. The influence of various parameters on the GMR measurement and a factor affecting in eddy current testing will be described in detail in the third part of this paper. Finally, this paper will discuss the limitations of coil probe and compensation techniques that researchers have applied in eddy current testing probes. A comprehensive review of previous studies on the application of GMR sensors in non-destructive eddy current testing also be given at the end of this paper.
Lambda Probe Measurements of Laboratory Spheromaks
NASA Astrophysics Data System (ADS)
Jorne, E.; Bellan, P. M.; Hsu, S. C.; Moynihan, C.
2003-10-01
A combined current and magnetic probe (lambda probe) has been constructed and is being tested for the purpose of investigating the behavior of spheromaks formed by the Caltech planar spheromak gun. The probe consists of a 1.5cm diameter, 52 turn Rogowski coil and a single loop magnetic coil, housed in a ceramic shell attached to a 95cm long hollow, steel shaft. A high voltage power supply was used to test the probe's ability to measure pulsed currents with submicrosecond rise times. A calibrated current pulse was provided by a 1μF capacitor discharged by a krytron switch to a low inductance circuit. Magnetic calibration was obtained by using the capacitor bank to power a 16cm diameter Helmholtz coil. Both magnetic and current calibration were in good agreement with estimates based on geometry. An existing steel shaft will be replaced by a ceramic shaft in order to minimize undesired effects on the plasma by a conductor. Once sealed with epoxy, the probe will be ready for insertion into the vacuum chamber and used to measure the magnetic field and parallel current during spheromak formation.
Electromechanical Apparatus Measures Residual Stress
NASA Technical Reports Server (NTRS)
Chern, Engmin J.; Flom, Yury
1993-01-01
Nondestructive test exploits relationship between stress and eddy-current-probe resistance. Yields data on residual stress or strain in metal tension/compression specimen (stress or strain remaining in specimen when no stress applied from without). Apparatus is assembly of commercial equipment: tension-or-compression testing machine, eddy-current probe, impedance gain-and-phase analyzer measuring impedance of probe coil, and desktop computer, which controls other equipment and processes data received from impedance gain-and-phase analyzer.
NONDESTRUCTIVE EDDY CURRENT TESTING
Renken, C.J. Jr.
1961-05-23
An eddy current testing device is described for measuring metal continuity independent of probe-to-sample spacing. An inductance would test probe is made a leg of a variable impedance bridge and the bridge is balanced with the probe away from the sample. An a-c signal is applied across the input terminals of the bridge circuit. As the probe is brought into proximity with the metal sample, the resulting impedance change in the probe gives an output signal from the bridge whose phase angle is proportional to the sample continuity and amplitude is proportional to the probe-tosample spacing. The output signal from the bridge is applied to a compensating network where, responsive to amplitude changes from the bridge output signal, a constant phased voltage output is maintained when the sample is continuous regardless of probe-to-sample spacing. A phase meter calibrated to read changes in resistivity of the metal sample measures the phase shift between the output of the compensating network and the original a-c signal applied to the bridge.
Determining confounding sensitivities in eddy current thin film measurements
NASA Astrophysics Data System (ADS)
Gros, Ethan; Udpa, Lalita; Smith, James A.; Wachs, Katelyn
2017-02-01
Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done by using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It was the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy-current testing was performed using a commercially available, hand-held eddy-current probe (ETA3.3H spring-loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe was sent to a hand-held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring-loaded eddy probe was at measuring film thickness under varying experimental conditions. This research studied the effects of a number of factors such as i) conductivity, ii) edge effect, iii) surface finish of base material and iv) cable condition.
Detection of Fatigue Cracks at Rivets with Self-Nulling Probe
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min
1994-01-01
A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further
Measurement technology of RF interference current in high current system
NASA Astrophysics Data System (ADS)
Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei
2018-06-01
Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.
Probe compensation in cylindrical near-field scanning: A novel simulation methodology
NASA Technical Reports Server (NTRS)
Hussein, Ziad A.; Rahmat-Samii, Yahya
1993-01-01
Probe pattern compensation is essential in near-field scanning geometry, where there is a great need to accurately know far-field patterns at wide angular range. This paper focuses on a novel formulation and computer simulation to determine the precise need for and effect of probe compensation in cylindrical near-field scanning. The methodology is applied to a linear test array antenna and the NASA scatterometer radar antenna. The formulation is based on representing the probe by its equivalent tangential magnetic currents. The interaction between the probe equivalent aperture currents and the test antenna fields is obtained with the application of a reciprocity theorem. This allows us to obtain the probe vector output pickup integral which is proportional to the amplitude and phase of the electric field induced in the probe aperture with respect to its position to the test antenna. The integral is evaluated for each probe position on the required sampling point on a cylindrical near-field surface enclosing the antenna. The use of a hypothetical circular-aperture probe with a different radius permits us to derive closed-form expressions for its far-field radiation patterns. These results, together with the probe vector output pickup, allow us to perform computer simulated synthetic measurements. The far-field patterns of the test antenna are formulated based on cylindrical wave expansions of both the probe and test antenna fields. In the limit as the probe radius becomes very small, the probe vector output is the direct response of the near-field at a point, and no probe compensation is needed. Useful results are generated to compare the far-field pattern of the test antenna constructed from the knowledge of the simulated near-field with and without probe pattern compensation and the exact results. These results are important since they clearly illustrate the angular range over which probe compensation is needed. It has been found that a probe with an aperture radius of 0.25(lambda), 0.5(lambda), and 1(lambda) needs a little probe compensation, if any, near the test antenna main beam. In addition, a probe with low directivity may provide a better signal-to-noise ratio than a highly directive one. This is evident in test antenna patterns without probe compensation at wide angles.
Solar probe shield developmental testing
NASA Technical Reports Server (NTRS)
Miyake, Robert N.
1991-01-01
The objectives of the Solar Probe mission and the current status of the Solar Probe thermal shield subsystem development are described. In particular, the discussion includes a brief description of the mission concepts, spacecraft configuration and shield concept, material selection criteria, and the required material testing to provide a database to support the development of the shield system.
Technique for temperature compensation of eddy-current proximity probes
NASA Technical Reports Server (NTRS)
Masters, Robert M.
1989-01-01
Eddy-current proximity probes are used in turbomachinery evaluation testing and operation to measure distances, primarily vibration, deflection, or displacment of shafts, bearings and seals. Measurements of steady-state conditions made with standard eddy-current proximity probes are susceptible to error caused by temperature variations during normal operation of the component under investigation. Errors resulting from temperature effects for the specific probes used in this study were approximately 1.016 x 10 to the -3 mm/deg C over the temperature range of -252 to 100 C. This report examines temperature caused changes on the eddy-current proximity probe measurement system, establishes their origin, and discusses what may be done to minimize their effect on the output signal. In addition, recommendations are made for the installation and operation of the electronic components associated with an eddy-current proximity probe. Several techniques are described that provide active on-line error compensation for over 95 percent of the temperature effects.
Simplified Numerical Analysis of ECT Probe - Eddy Current Benchmark Problem 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sikora, R.; Chady, T.; Gratkowski, S.
2005-04-09
In this paper a third eddy current benchmark problem is considered. The objective of the benchmark is to determine optimal operating frequency and size of the pancake coil designated for testing tubes made of Inconel. It can be achieved by maximization of the change in impedance of the coil due to a flaw. Approximation functions of the probe (coil) characteristic were developed and used in order to reduce number of required calculations. It results in significant speed up of the optimization process. An optimal testing frequency and size of the probe were achieved as a final result of the calculation.
Test module development to detect the flase call probe pins on microeprocessor test equipment
NASA Astrophysics Data System (ADS)
Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.
2017-09-01
Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.
NASA Technical Reports Server (NTRS)
Baskaran, Subbiah; Ramachandran, Narayanan; Noever, David
1998-01-01
The use of probabilistic (PNN) and multilayer feed forward (MLFNN) neural networks are investigated for calibration of multi-hole pressure probes and the prediction of associated flow angularity patterns in test flow fields. Both types of networks are studied in detail for their calibration and prediction characteristics. The current formalism can be applied to any multi-hole probe, however the test results for the most commonly used five-hole Cone and Prism probe types alone are reported in this article.
Eddy current inspection of graphite fiber components
NASA Technical Reports Server (NTRS)
Workman, G. L.; Bryson, C. C.
1990-01-01
The recognition of defects in materials properties still presents a number of problems for nondestructive testing in aerospace systems. This project attempts to utilize current capabilities in eddy current instrumentation, artificial intelligence, and robotics in order to provide insight into defining geometrical aspects of flaws in composite materials which are capable of being evaluated using eddy current inspection techniques. The unique capabilities of E-probes and horseshoe probes for inspecting probes for inspecting graphite fiber materials were evaluated and appear to hold great promise once the technology development matures. The initial results are described of modeling eddy current interactions with certain flaws in graphite fiber samples.
Anechoic Chamber test of the Electromagnetic Measurement System ground test unit
NASA Astrophysics Data System (ADS)
Stevenson, L. E.; Scott, L. D.; Oakes, E. T.
1987-04-01
The Electromagnetic Measurement System (EMMS) will acquire data on electromagnetic (EM) environments at key weapon locations on various aircraft certified for nuclear weapons. The high-frequency ground unit of the EMMS consists of an instrumented B61 bomb case that will measure (with current probes) the localized current density resulting from an applied EM field. For this portion of the EMMS, the first system test was performed in the Anechoic Chamber Facility at Sandia National Laboratories, Albuquerque, New Mexico. The EMMS pod was subjected to EM radiation at microwave frequencies of 1, 3, and 10 GHz. At each frequency, the EMMS pod was rotated at many positions relative to the microwave source so that the individual current probes were exposed to a direct line-of-sight illumination. The variations between the measured and calculated electric fields for the current probes with direct illumination by the EM source are within a few db. The results obtained from the anechoic test were better than expected and verify that the high frequency ground portion of the EMMS will accurately measure the EM environments for which it was designed.
Corrosion Detection in Airframes Using a New Flux-Focusing Eddy Current Probe
NASA Technical Reports Server (NTRS)
Fulton, James P.; Wincheski, Buzz; Nath, Shridhar; Namkung, Min
1994-01-01
A new flux-focusing eddy current probe was recently developed at NASA Langley Research Center. The new probe is similar in design to a reflection type eddy current probe, but is unique in that it does not require the use of an impedance bridge for balancing. The device monitors the RMS output voltage of a pickup coil and, as a result, is easier to operate and interpret than traditional eddy current instruments. The unique design feature of the probe is a ferromagnetic cylinder, typically 1020 steel, which separates a concentrically positioned drive and pickup coil. The increased permeability of the steel causes the magnetic flux produced by the drive coil to be focused in a ring around the pickup coil. At high frequencies the eddy currents induced in both the sample and the cylinder allow little or no flux to link with the pickup coil. This results in a self-nulling condition which has been shown to be useful for the unambiguous detection of cracks in conducting materials. As the frequency is lowered the flux produced by the drive coil begins to link with the pickup coil causing an output which, among other things, is proportional to the thickness of the test specimen. This enables highly accurate measurements of the thickness of conducting materials and helps to facilitate the monitoring of thickness variations in a conducting structure such as an aircraft fuselage. Under ideal laboratory conditions the probe can sense thickness changes on the order of 1% as illustrated. However, this is highly dependent upon the thickness, and the geometric complexity of the sample being tested and for practical problems the sensitivity is usually much less. In this presentation we highlight some of the advantages and limitations in using the probe to inspect aircraft panels for corrosion and other types of material nonuniformities. In particular, we present preliminary results which illustrate the probes capabilities for detecting first and second layer corrosion in aircraft panels which may contain air gaps between the layers. Since the probe utilized eddy currents its corrosion detection capabilities are similar to convectional eddy current techniques, but the new probe is much easier to use.
Self-Nulling Eddy Current Probe for Surface and Subsurface Flaw Detection
NASA Technical Reports Server (NTRS)
Wincheski, B.; Fulton, J. P.; Nath, S.; Namkung, M.; Simpson, J. W.
1994-01-01
An eddy current probe which provides a null-signal in the presence of unflawed material without the need for any balancing circuitry has been developed at NASA Langley Research Center. Such a unique capability of the probe reduces set-up time, eliminates tester configuration errors, and decreases instrumentation requirements. The probe is highly sensitive to surface breaking fatigue cracks, and shows excellent resolution for the measurement of material thickness, including material loss due to corrosion damage. The presence of flaws in the material under test causes an increase in the extremely stable and reproducible output voltage of the probe. The design of the probe and some examples illustrating its flaw detection capabilities are presented.
Plasma properties and heating at the anode of a 1 kW arcjet using electrostatic probes
NASA Astrophysics Data System (ADS)
Tiliakos, Nicholas
A 1 kW hydrazine arcjet thruster has been modified for internal probing of the near-anode boundary layer with an array of fourteen electrostatic micro-probes. The main objectives of this experimental investigation were to: (1) obtain axial and azimuthal distributions of floating potential phisbf, anode sheath potential phisbs, probe current density at zero volts jsba, electron number density nsbes, electron temperature Tsbes, and anode heating due to electrons qsbe for arc currents Isbarc, between 7.8 and 10.6 A, propellant flow rates m = 40-60 mg/s, and specific energies, 18.8 MJ/kg ≤ P/m ≤ 27.4 MJ/kg; (2) probe the anode boundary layer using flush-mounted and cylindrical micro-probes; (3) verify azimuthal current symmetry; (4) understand what affects anode heating, a critical thruster lifetime issue; and (5) provide experimental data for validation of the Megli-Krier-Burton (MKB) model. All of the above objectives were met through the design, fabrication and implementation of fourteen electrostatic micro-probes, of sizes ranging from 0.170 mm to 0.43 mm in diameter. A technique for cleaning and implementing these probes was developed. Two configurations were used: flush-mounted planar probes and cylindrical probes extended 0.10-0.30 mm into the plasma flow. The main results of this investigation are: (1) electrostatic micro-probes can successfully be used in the harsh environment of an arcjet; (2) under all conditions tested the plasma is highly non-equilibrium in the near-anode region; (3) azimuthal current symmetry exists for most operating conditions; (4) the propellant flow rate affects the location of maximum anode sheath potential, current density, and anode heating more than the arc current; (5) the weighted anode sheath potential is always positive and varies from 8-17 V depending on thruster operating conditions; (6) the fraction of anode heating varies from 18-24% of the total input power over the range of specific energies tested; and (7) based on an energy loss factor of delta = 1200, reasonable correlation between the experimental data and the MKB model was found.
Design and test of voltage and current probes for EAST ICRF antenna impedance measurement
NASA Astrophysics Data System (ADS)
Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG
2018-04-01
On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L < 1.5 Ω, which implies that the power loss cannot be neglected at high VSWR. As the factors that give rise to the deviation of coupling resistance calculation, the phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.
Pulsed eddy current differential probe to detect the defects in a stainless steel pipe
NASA Astrophysics Data System (ADS)
Angani, C. S.; Park, D. G.; Kim, C. G.; Leela, P.; Kishore, M.; Cheong, Y. M.
2011-04-01
Pulsed eddy current (PEC) is an electromagnetic nondestructive technique widely used to detect and quantify the flaws in conducting materials. In the present study a differential Hall-sensor probe which is used in the PEC system has been fabricated for the detection of defects in stainless steel pipelines. The differential probe has an exciting coil with two Hall-sensors. A stainless steel test sample with electrical discharge machining (EDM) notches under different depths of 1-5 mm was made and the sample was laminated by plastic insulation having uniform thickness to simulate the pipelines in nuclear power plants (NPPs). The driving coil in the probe is excited by a rectangular current pulse and the resultant response, which is the difference of the two Hall-sensors, has been detected as the PEC probe signal. The discriminating time domain features of the detected pulse such as peak value and time to zero are used to interpret the experimental results with the defects in the test sample. A feature extraction technique such as spectral power density has been devised to infer the PEC response.
Determining Confounding Sensitivities In Eddy Current Thin Film Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gros, Ethan; Udpa, Lalita; Smith, James A.
Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs inmore » the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring loaded eddy probe is at measuring film thickness under varying experimental conditions. This research will study the effects of a number of factors such as i) calibration, ii) conductivity, iii) edge effect, iv) surface finish of base material and v) cable condition and compare with the long term reproducibility of a standard measurement. This work was performed with support from the Department of Energy under the United States National Nuclear Security Administration (NNSA) at the Idaho National Laboratory.« less
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Hill, Carrie S.
2013-01-01
Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are useful for performing measurements in electric space thrusters and various plasma accelerator applications where a time-varying magnetic field is present. Magnetic field probes have proven to be a mainstay in diagnosing plasma thrusters where changes occur rapidly with respect to time, providing the means to measure the magnetic fields produced by time-varying currents and even an indirect measure of the plasma current density through the application of Ampère's law. Examples of applications where this measurement technique has been employed include pulsed plasma thrusters and quasi-steady magnetoplasmadynamic thrusters. The Electric Propulsion Technical Committee (EPTC) of the American Institute of Aeronautics and Astronautics (AIAA) was asked to assemble a Committee on Standards (CoS) for Electric Propulsion Testing. The assembled CoS was tasked with developing Standards and Recommended Practices for various diagnostic techniques used in the evaluation of plasma thrusters. These include measurements that can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. This paper presents a summary of the standard, describing the preferred methods for fabrication, calibration, and usage of inductive magnetic field probes for use in diagnosing plasma thrusters. Inductive magnetic field probes (also called B-dot probes throughout this document) are commonly used in electric propulsion (EP) research and testing to measure unsteady magnetic fields produced by time-varying currents. The B-dot probe is relatively simple in construction, and requires minimal cost, making it a low-cost technique that is readily accessible to most researchers. While relatively simple, the design of a B-dot probe is not trivial and there are many opportunities for errors in probe construction, calibration, and usage, and in the post-processing of data that is produced by the probe. There are typically several ways in which each of these steps can be approached, and different applications may require more or less vigorous attention to various issues.
Magnetically Filtered Faraday Probe for Measuring the Ion Current Density Profile of a Hall Thruster
2006-01-01
Hall thruster is investigated. The MFFP is designed to eliminate the collection of low-energy, charge-exchange (CEX) ions by using a variable magnetic field as an ion filter. In this study, a MFFP, Faraday probe with a reduced acceptance angle (BFP), and nude Faraday probe are used to measure the ion current density profile of a 5 kW Hall thruster operating over the range of 300-500 V and 5-10 mg/s. The probes are evaluated on a xenon propellant Hall thruster in the University of Michigan Large Vacuum Test Facility at operating
Prince, J.M.; Dodson, M.G.; Lechelt, W.M.
1989-07-18
A system for measuring the hardness of cartridge cases employs an eddy current probe for inducing and sensing eddy currents in each cartridge case. A first component of the sensed signal is utilized in a closed loop system for accurately positioning the probe relative to the cartridge case both in the lift off direction and in the tangential direction, and a second component of the sensed signal is employed as a measure of the hardness. The positioning and measurement are carried out under closed loop microprocessor control facilitating hardness testing on a production line basis. 14 figs.
Prince, James M.; Dodson, Michael G.; Lechelt, Wayne M.
1989-01-01
A system for measuring the hardness of cartridge cases employs an eddy current probe for inducing and sensing eddy currents in each cartridge case. A first component of the sensed signal is utilized in a closed loop system for accurately positioning the probe relative to the cartridge case both in the lift off direction and in the tangential direction, and a second component of the sensed signal is employed as a measure of the hardness. The positioning and measurement are carried out under closed loop microprocessor control facilitating hardness testing on a production line basis.
NASA Astrophysics Data System (ADS)
Claycomb, James Ronald
1998-10-01
Several High-T c Superconducting (HTS) eddy current probes have been developed for applications in electromagnetic nondestructive evaluation (NDE) of conducting materials. The probes utilize high-T c SUperconducting Quantum Interference Device (SQUID) magnetometers to detect the fields produced by the perturbation of induced eddy currents resulting from subsurface flaws. Localized HTS shields are incorporated to selectively screen out environmental electromagnetic interference and enable movement of the instrument in the Earth's magnetic field. High permeability magnetic shields are employed to focus flux into, and thereby increase the eddy current density in the metallic test samples. NDE test results are presented, in which machined flaws in aluminum alloy are detected by probes of different design. A novel current injection technique performing NDE of wires using SQUIDs is also discussed. The HTS and high permeability shields are designed based on analytical and numerical finite element method (FEM) calculations presented here. Superconducting and high permeability magnetic shields are modeled in uniform noise fields and in the presence of dipole fields characteristic of flaw signals. Several shield designs are characterized in terms of (1) their ability to screen out uniform background noise fields; (2) the resultant improvement in signal-to-noise ratio and (3) the extent to which dipole source fields are distorted. An analysis of eddy current induction is then presented for low frequency SQUID NDE. Analytical expressions are developed for the induced eddy currents and resulting magnetic fields produced by excitation sources above conducting plates of varying thickness. The expressions derived here are used to model the SQUID's response to material thinning. An analytical defect model is also developed, taking into account the attenuation of the defect field through the conducting material, as well as the current flow around the edges of the flaw. Time harmonic FEM calculations are then used to model the electromagnetic response of eight probe designs, consisting of an eddy current drive coil coupled to a SQUID surrounded by superconducting and/or high permeability magnetic shielding. Simulations are carried out with the eddy current probes located a finite distance above a conducting surface. Results are quantified in terms of shielding and focus factors for each probe design.
NON-DESTRUCTIVE METHOD AND MEANS FOR FLAW DETECTION
Hochschild, R.
1959-03-10
BS>An improved method is presented for the nondestructive detection of flaws in olectrictilly conductivc articles using magnetic field. According to thc method a homogoneous mignetic field is established in the test article;it right angle" to the artyicle. A probe is aligned with its axis transverse to the translates so hat th4 probe scans the surface of the test article while the axis of the robe is transverse to the direction of translation of the article. In this manner any output current obtained in thc probe is an indication of the size and location of a flaw in the article under test, with a miiiimum of signal pick- up in the probe from the established magnetic field.
Computer programs for eddy-current defect studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pate, J. R.; Dodd, C. V.
Several computer programs to aid in the design of eddy-current tests and probes have been written. The programs, written in Fortran, deal in various ways with the response to defects exhibited by four types of probes: the pancake probe, the reflection probe, the circumferential boreside probe, and the circumferential encircling probe. Programs are included which calculate the impedance or voltage change in a coil due to a defect, which calculate and plot the defect sensitivity factor of a coil, and which invert calculated or experimental readings to obtain the size of a defect. The theory upon which the programs aremore » based is the Burrows point defect theory, and thus the calculations of the programs will be more accurate for small defects. 6 refs., 21 figs.« less
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.
2008-01-01
Thick, multi-layer aluminum structure has been widely used in aircraft design in critical wing splice areas. The multi-layer structure generally consists of three or four aluminum layers with different geometry and varying thickness, which are held together with fasteners. The detection of cracks under fasteners with ultrasonic techniques in subsurface layers away from the skin is impeded primarily by interlayer bonds and faying sealant condition. Further, assessment of such sealant condition is extremely challenging in terms of complexity of structure, limited access, and inspection cost. Although Eddy current techniques can be applied on in-service aircraft from the exterior of the skin without knowing sealant condition, the current eddy current techniques are not able to detect defects with wanted sensitivity. In this work a series of low frequency eddy current probes have been designed, fabricated and tested for this application. A probe design incorporating a shielded magnetic field sensor concentrically located in the interior of a drive coil has been employed to enable a localized deep diffusion of the electromagnetic field into the part under test. Due to the required low frequency inspections, probes have been testing using a variety of magnetic field sensors (pickup coil, giant magneto-resistive, anisotropic magneto-resistive, and spin-dependent tunneling). The probe designs as well as capabilities based upon a target inspection for sub-layer cracking in an airframe wing spar joint is presented.
Numerical modeling of probe velocity effects for electromagnetic NDE methods
NASA Astrophysics Data System (ADS)
Shin, Y. K.; Lord, W.
The present discussion of magnetic flux (MLF) leakage inspection introduces the behavior of motion-induced currents. The results obtained indicate that velocity effects exist at even low probe speeds for magnetic materials, compelling the inclusion of velocity effects in MLF testing of oil pipelines, where the excitation level and pig speed are much higher than those used in the present work. Probe velocity effect studies should influence probe design, defining suitable probe speed limits and establishing training guidelines for defect-characterization schemes.
The eddy current probe array for Keda Torus eXperiment.
Li, Zichao; Li, Hong; Tu, Cui; Hu, Jintong; You, Wei; Luo, Bing; Tan, Mingsheng; Adil, Yolbarsop; Wu, Yanqi; Shen, Biao; Xiao, Bingjia; Zhang, Ping; Mao, Wenzhe; Wang, Hai; Wen, Xiaohui; Zhou, Haiyang; Xie, Jinlin; Lan, Tao; Liu, Adi; Ding, Weixing; Xiao, Chijin; Liu, Wandong
2016-11-01
In a reversed field pinch device, the conductive shell is placed as close as possible to the plasma so as to balance the plasma during discharge. Plasma instabilities such as the resistive wall mode and certain tearing modes, which restrain the plasma high parameter operation, respond closely with conditions in the wall, in essence the eddy current present. Also, the effect of eddy currents induced by the external coils cannot be ignored when active control is applied to control instabilities. One diagnostic tool, an eddy current probe array, detects the eddy current in the composite shell. Magnetic probes measuring differences between the inner and outer magnetic fields enable estimates of the amplitude and angle of these eddy currents. Along with measurements of currents through the copper bolts connecting the poloidal shield copper shells, we can obtain the eddy currents over the entire shell. Magnetic field and eddy current resolutions approach 2 G and 6 A, respectively. Additionally, the vortex electric field can be obtained by eddy current probes. As the conductivity of the composite shell is high, the eddy current probe array is very sensitive to the electric field and has a resolution of 0.2 mV/cm. In a bench test experiment using a 1/4 vacuum vessel, measurements of the induced eddy currents are compared with simulation results based on a 3D electromagnetic model. The preliminary data of the eddy currents have been detected during discharges in a Keda Torus eXperiment device. The typical value of toroidal and poloidal eddy currents across the magnetic probe coverage rectangular area could reach 3.0 kA and 1.3 kA, respectively.
Development of eddy current probe for fiber orientation assessment in carbon fiber composites
NASA Astrophysics Data System (ADS)
Wincheski, Russell A.; Zhao, Selina
2018-04-01
Measurement of the fiber orientation in a carbon fiber composite material is crucial in understanding the load carrying capability of the structure. As manufacturing conditions including resin flow and molding pressures can alter fiber orientation, verification of the as-designed fiber layup is necessary to ensure optimal performance of the structure. In this work, the development of an eddy current probe and data processing technique for analysis of fiber orientation in carbon fiber composites is presented. A proposed directional eddy current probe is modeled and its response to an anisotropic multi-layer conductor simulated. The modeling results are then used to finalize specifications of the eddy current probe. Experimental testing of the fabricated probe is presented for several samples including a truncated pyramid part with complex fiber orientation draped to the geometry for resin transfer molding. The inductively coupled single sided measurement enables fiber orientation characterization through the thickness of the part. The fast and cost-effective technique can be applied as a spot check or as a surface map of the fiber orientations across the structure. This paper will detail the results of the probe design, computer simulations, and experimental results.
New Eddy Current Probe for Thickness Gauging of Conductive Materials
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min
1993-01-01
The accurate measure of material thickness is important for many non-destructive evaluation applications. Factors such as corrosion damage can jeopardize structural integrity through material thinning and process control considerations often mandate strict limits on material dimensions. Access to the material under test can be limited to a single side and large areas may need to be examined in a small time period. In an effort to enhance the effectiveness of material thickness measurements a flux focusing eddy current probe has been developed at NASA Langley Research Center. The probe provides an accurate measure of the thickness of conducting materials from a single sided measurement. It is straight forward to use and can be easily automated for production line testing. The probe also requires only minimal instrumentation and power so that extremely portable units can be manufactured at a low cost. This new eddy current probe has been used to accurately measure the thickness of aluminum alloy plates with a resolution of greater than 0.001 in. (25 microns). Simulated corrosion damage has also been detected on both single layer and multi-layer samples. The present work will explain the output voltage dependence of the device as a function of material thickness and present experimental results for thickness gauging and corrosion detection.
Eddy current testing probe with dual half-cylindrical coils
NASA Astrophysics Data System (ADS)
Bae, Byung-Hoon; Choi, Jung-Mi; Kim, Soo-Yong
2000-02-01
We have developed a new eddy current probe composed of a dual half-cylindrical (2HC) coil as an exciting coil and a sensing coil that is placed in the small gap of the 2HC coil. The 2HC coil induces a linear eddy current on the narrow region within the target medium. The magnitude of eddy current has a maximum peak with the narrow width, underneath the center of the exciting 2HC coil. Because of the linear eddy current, the probe can be used to detect not only the existence of a crack but also its direction in conducting materials. Using specimen with a machined crack, and varying the exciting frequency from 0.5 to 100 kHz, we investigated the relationships between the direction of crack and the output voltage of the sensing coil.
Eddy-Current Detection of Cracks in Tubes
NASA Technical Reports Server (NTRS)
Parent, R.; Kettering, D.
1987-01-01
Nondestructive device tests narrow, sharply-bent metal tubes. Eddycurrent probe detects incipient cracks inside small metal tubes. Tube-centering device consisting of pair of opposed bars ensures tube centered on eddy-current coil. Probe moves along length of bent tube to inspect repeatably for cracks. Compatible with tubes of different cross sections, oval, flattened, square, rectangular,or irregular. Adapts for inspecting formed tubes in petrochemical, automotive, nuclear, and medical equipment.
The Sheath-less Planar Langmuir Probe
NASA Astrophysics Data System (ADS)
Cooke, D. L.
2017-12-01
The Langmuir probe is one of the oldest plasma diagnostics, provided the plasma density and species temperature from analysis of a current-voltage curve as the voltage is swept over a practically chosen range. The analysis depends on a knowledge or theory of the many factors that influence the current-voltage curve including, probe shape, size, nearby perturbations, and the voltage reference. For applications in Low Earth Orbit, the Planar Langmuir Probe, PLP, is an attractive geometry because the ram ion current is very constant over many Volts of a sweep, allowing the ion density and electron temperature to be determined independently with the same instrument, at different points on the sweep. However, when the physical voltage reference is itself small and electrically floating as with a small spacecraft, the spacecraft and probe system become a double probe where the current collection theory depends on the interaction of the spacecraft with the plasma which is generally not as simple as the probe itself. The Sheath-less PLP, SPLP, interlaces on a single ram facing surface, two variably biased probe elements, broken into many small and intertwined segments on a scale smaller than the plasma Debye length. The SPLP is electrically isolated from the rest of the spacecraft. For relative bias potentials of a few volts, the ion current to all segments of each element will be constant, while the electron currents will vary as a function of the element potential and the electron temperature. Because the segments are small, intertwined, and floating, the assembly will always present the same floating potential to the plasma, with minimal growth as a function of voltage, thus sheath-less and still planar. This concept has been modelled with Nascap, and tested with a physical model inserted into a Low Earth Orbit-like chamber plasma. Results will be presented.
2007-06-01
massive RF power to the antenna feed points without providing an inductive path to earth. Given all the above challenges, and especially the... circuit theory currents are flowing limited by the three parallel 50 ohm resistances and low inductive reactance. This plateaus at eigencurrent...relative to nett TEM cell input power has been calculated: Figure 86 Expected power output from probe, neglecting probe inductance DSTO-RR-0329
NASA Astrophysics Data System (ADS)
Oudini, N.; Sirse, N.; Taccogna, F.; Ellingboe, A. R.; Bendib, A.
2018-05-01
We propose a new technique for diagnosing negative ion properties using Langmuir probe assisted pulsed laser photo-detachment. While the classical technique uses a laser pulse to convert negative ions into electron-atom pairs and a positively biased Langmuir probe tracking the change of electron saturation current, the proposed method uses a negatively biased Langmuir probe to track the temporal evolution of positive ion current. The negative bias aims to avoid the parasitic electron current inherent to probe tip surface ablation. In this work, we show through analytical and numerical approaches that, by knowing electron temperature and performing photo-detachment at two different laser wavelengths, it is possible to deduce plasma electronegativity (ratio of negative ion to electron densities) α, and anisothermicity (ratio of electron to negative ion temperatures) γ-. We present an analytical model that links the change in the collected positive ion current to plasma electronegativity and anisothermicity. Particle-In-Cell simulation is used as a numerical experiment covering a wide range of α and γ- to test the new analysis technique. The new technique is sensitive to α in the range 0.5 < α < 10 and yields γ- for large α, where negative ion flux affects the probe sheath behavior, typically α > 1.
Detection of Cracks at Welds in Steel Tubing Using Flux Focusing Electromagnetic Probe
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Simpson, John; Namkung, Min
1994-01-01
The inspection of weldments in critical pressure vessel joints is a major concern in the nuclear power industry. Corrosive environments can speed the fatigue process and access to the critical area is often limited. Eddy current techniques have begun to be used to help overcome these obstacles [1]. As direct contact and couplants are not required, remote areas can be inspected by simply snaking an eddy current coil into the intake tube of the vessel. The drawback of the eddy current method has been the high sensitivity to small changes in the conductivity and permeability of the test piece which are known to vary at weldments [1]. The flaw detection mechanism of the flux focusing electromagnetic probe can help alleviate these difficulties and provide a unique capability for detecting longitudinal fatigue cracks in critical tube structures. The Flux Focusing Electromagnetic Flaw Detector, originally invented for the detection of fatigue and corrosion damage in aluminum plates [2-3], has been adapted for use in testing steel tubing for longitudinal fatigue cracks. The modified design allows for the probe to be placed axisymmetrically into the tubing, inducing eddy currents in the tube wall. The pickup coil of the probe is fixed slightly below the primary windings and is rotated 90 so that its axis is normal to the tube wall. The magnetic flux of the primary coil is focused through the use of ferromagnetic material so that in the absence of fatigue damage there will be no flux linkage with the pickup coil. The presence of a longitudinal fatigue crack will cause the eddy currents induced in the tube wall to flow around the flaw and directly under the pickup coil. The magnetic field associated with these currents will then link the pickup coil and an unambiguous increase in the output voltage of the probe will be measured. The use of the flux focusing electromagnetic probe is especially suited for the detection of flaws originating at or near tube welds. The probe is shown to discriminate against signals due solely to the weld joint so that flaw signals are not hidden in the background in these locations. Experimental and finite element modeling results are presented for the flaw detection capabilities of the probe in stainless steel tubes.
Scanning ion-conductance and atomic force microscope with specialized sphere-shaped nanopippettes
NASA Astrophysics Data System (ADS)
Zhukov, M. V.; Sapozhnikov, I. D.; Golubok, A. O.; Chubinskiy-Nadezhdin, V. I.; Komissarenko, F. E.; Lukashenko, S. Y.
2017-11-01
A scanning ion-conductance microscope was designed on the basis of scanning probe microscope NanoTutor. The optimal parameters of nanopipettes fabrication were found according to scanning electron microscopy diagnostics, current-distance I (Z) and current-voltage characteristics. A comparison of images of test objects, including biological samples, was carried out in the modes of optical microscopy, atomic force microscopy and scanning ion-conductance microscopy. Sphere-shaped nanopippettes probes were developed and tested to increase the stability of pipettes, reduce invasiveness and improve image quality of atomic force microscopy in tapping mode. The efficiency of sphere-shaped nanopippettes is shown.
pathChirp: Efficient Available Bandwidth Estimation for Network Paths
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cottrell, Les
2003-04-30
This paper presents pathChirp, a new active probing tool for estimating the available bandwidth on a communication network path. Based on the concept of ''self-induced congestion,'' pathChirp features an exponential flight pattern of probes we call a chirp. Packet chips offer several significant advantages over current probing schemes based on packet pairs or packet trains. By rapidly increasing the probing rate within each chirp, pathChirp obtains a rich set of information from which to dynamically estimate the available bandwidth. Since it uses only packet interarrival times for estimation, pathChirp does not require synchronous nor highly stable clocks at the sendermore » and receiver. We test pathChirp with simulations and Internet experiments and find that it provides good estimates of the available bandwidth while using only a fraction of the number of probe bytes that current state-of-the-art techniques use.« less
NASA Astrophysics Data System (ADS)
Beck, Faith R.; Lind, R. Paul; Smith, James A.
2018-04-01
Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the instrumentation must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature.
van Wijck, Kim; Bessems, Babs Afm; van Eijk, Hans Mh; Buurman, Wim A; Dejong, Cornelis Hc; Lenaerts, Kaatje
2012-01-01
Increased intestinal permeability is an important measure of disease activity and prognosis. Currently, many permeability tests are available and no consensus has been reached as to which test is most suitable. The aim of this study was to compare urinary probe excretion and accuracy of a polyethylene glycol (PEG) assay and dual sugar assay in a double-blinded crossover study to evaluate probe excretion and the accuracy of both tests. Gastrointestinal permeability was measured in nine volunteers using PEG 400, PEG 1500, and PEG 3350 or lactulose-rhamnose. On 4 separate days, permeability was analyzed after oral intake of placebo or indomethacin, a drug known to increase intestinal permeability. Plasma intestinal fatty acid binding protein and calprotectin levels were determined to verify compromised intestinal integrity after indomethacin consumption. Urinary samples were collected at baseline, hourly up to 5 hours after probe intake, and between 5 and 24 hours. Urinary excretion of PEG and sugars was determined using high-pressure liquid chromatography-evaporative light scattering detection and liquid chromatography-mass spectrometry, respectively. Intake of indomethacin increased plasma intestinal fatty acid-binding protein and calprotectin levels, reflecting loss of intestinal integrity and inflammation. In this state of indomethacin-induced gastrointestinal compromise, urinary excretion of the three PEG probes and lactulose increased compared with placebo. Urinary PEG 400 excretion, the PEG 3350/PEG 400 ratio, and the lactulose/rhamnose ratio could accurately detect indomethacin-induced increases in gastrointestinal permeability, especially within 2 hours of probe intake. Hourly urinary excretion and diagnostic accuracy of PEG and sugar probes show high concordance for detection of indomethacin-induced increases in gastrointestinal permeability. This comparative study improves our knowledge of permeability analysis in man by providing a clear overview of both tests and demonstrates equivalent performance in the current setting.
Fang, Jiancheng; Wen, Tong
2012-01-01
The Eddy Current Displacement Sensor (ECDS) is widely used in the Magnetic Suspension Flywheel (MSFW) to measure the tiny clearance between the rotor and the magnetic bearings. The linear range of the ECDS is determined by the diameter of its probe coil. Wide clearances must be measured in some new MSFWs recently designed for the different space missions, but the coil diameter is limited by some restrictions. In this paper, a multi-channel ECDS equipped with dual-coil probes is proposed to extend the linear range to satisfy the demands of such MSFWs. In order to determine the best configuration of the dual-coil probe, the quality factors of the potential types of the dual-coil probes, the induced eddy current and the magnetic intensity on the surface of the measuring object are compared with those of the conventional single-coil probe. The linear range of the ECDS equipped with the selected dual-coil probe is extended from 1.1 mm to 2.4 mm under the restrictions without adding any cost for additional compensation circuits or expensive coil materials. The effectiveness of the linear range extension ability and the dynamic response of the designed ECDS are confirmed by the testing and the applications in the MSFW.
An Effective Electrical Resonance-Based Method to Detect Delamination in Thermal Barrier Coating
NASA Astrophysics Data System (ADS)
Kim, Jong Min; Park, Jae-Ha; Lee, Ho Girl; Kim, Hak-Joon; Song, Sung-Jin; Seok, Chang-Sung; Lee, Young-Ze
2017-12-01
This research proposes a simple yet highly sensitive method based on electrical resonance of an eddy-current probe to detect delamination of thermal barrier coating (TBC). This method can directly measure the mechanical characteristics of TBC compared to conventional ultrasonic testing and infrared thermography methods. The electrical resonance-based method can detect the delamination of TBC from the metallic bond coat by shifting the electrical impedance of eddy current testing (ECT) probe coupling with degraded TBC, and, due to this shift, the resonant frequencies near the peak impedance of ECT probe revealed high sensitivity to the delamination. In order to verify the performance of the proposed method, a simple experiment is performed with degraded TBC specimens by thermal cyclic exposure. Consequently, the delamination with growth of thermally grown oxide in a TBC system is experimentally identified. Additionally, the results are in good agreement with the results obtained from ultrasonic C-scanning.
An Effective Electrical Resonance-Based Method to Detect Delamination in Thermal Barrier Coating
NASA Astrophysics Data System (ADS)
Kim, Jong Min; Park, Jae-Ha; Lee, Ho Girl; Kim, Hak-Joon; Song, Sung-Jin; Seok, Chang-Sung; Lee, Young-Ze
2018-02-01
This research proposes a simple yet highly sensitive method based on electrical resonance of an eddy-current probe to detect delamination of thermal barrier coating (TBC). This method can directly measure the mechanical characteristics of TBC compared to conventional ultrasonic testing and infrared thermography methods. The electrical resonance-based method can detect the delamination of TBC from the metallic bond coat by shifting the electrical impedance of eddy current testing (ECT) probe coupling with degraded TBC, and, due to this shift, the resonant frequencies near the peak impedance of ECT probe revealed high sensitivity to the delamination. In order to verify the performance of the proposed method, a simple experiment is performed with degraded TBC specimens by thermal cyclic exposure. Consequently, the delamination with growth of thermally grown oxide in a TBC system is experimentally identified. Additionally, the results are in good agreement with the results obtained from ultrasonic C-scanning.
NASA Astrophysics Data System (ADS)
Winebrenner, D. P.; Elam, W. T.; Carpenter, M.; Kintner, P., III
2014-12-01
More numerous observations within and beneath ice sheets are needed to address a broad variety of important questions concerning ice sheets and climate. However, emplacement of instruments continues to be constrained by logistical burdens, especially in cold ice a kilometer or more thick. Electrically powered thermal melt probes are inherently logistically light and efficient, especially for reaching greater depths in colder ice. They therefore offer a means of addressing current measurement problems, but have been limited historically by a lack of technology for reliable operation at the necessary voltages and powers. Here we report field tests in Greenland of two new melt probes. We operated one probe at 2.2 kilowatts (kW) and 1050 volts (V), achieving a depth of 400 m in the ice in ~ 120 hours, without electrical failure. That depth is the second greatest achieved thus far with a thermal melt probe, exceeded only by one deployment to 1005 m in Greenland in 1968, which ended in an electrical failure. Our test run took place in two intervals separated by a year, with the probe frozen at 65 m depth during the interim, after which we re-established communication, unfroze the probe, and proceeded to the greater depth. During the second field test we operated a higher-power probe, initially at 2.5 kW and 1500 V and progressing to 4.5 kW and 2000 V. Initial data indicate that this probe achieved a descent rate of 8 m/hr, which if correct would be the fastest rate yet achieved for such probes. Moreover, we observed maintenance of vertical probe travel using pendulum steering throughout both tests, as well as autonomous descent without operator-intervention after launch. The latter suggests potential for crews of 1-2 to operate several melt probes concurrently. However, the higher power probe did suffer electrical failure of a heating element after 7 hours of operation at 2000 V (24 hours after the start of the test), contrary to expectations based on laboratory component and system testing. We are therefore revising the probe heaters using a newer but more development-intensive technology. With probe systems now validated in our tests, this will result in a reliable means to emplace instruments for studies of subglacial hydrology, ice dynamics, and possible subglacial ecologies.
Nance, Roy A.; Hartley, William H.; Caffarel, Alfred J.
1984-01-01
Apparatus is described for detecting flaws in a tubular workpiece in a single scan. The coils of a dual coil bobbin eddy current inspection probe are wound at a 45.degree. angle to the transverse axis of the probe, one coil having an angular position about the axis about 90.degree. relative to the angular position of the other coil, and the angle of intersection of the planes containing the coils being about 60.degree..
High Accuracy Temperature Measurements Using RTDs with Current Loop Conditioning
NASA Technical Reports Server (NTRS)
Hill, Gerald M.
1997-01-01
To measure temperatures with a greater degree of accuracy than is possible with thermocouples, RTDs (Resistive Temperature Detectors) are typically used. Calibration standards use specialized high precision RTD probes with accuracies approaching 0.001 F. These are extremely delicate devices, and far too costly to be used in test facility instrumentation. Less costly sensors which are designed for aeronautical wind tunnel testing are available and can be readily adapted to probes, rakes, and test rigs. With proper signal conditioning of the sensor, temperature accuracies of 0.1 F is obtainable. For reasons that will be explored in this paper, the Anderson current loop is the preferred method used for signal conditioning. This scheme has been used in NASA Lewis Research Center's 9 x 15 Low Speed Wind Tunnel, and is detailed.
NASA Technical Reports Server (NTRS)
Namkung, M.; Nath, S.; Wincheski, B.; Fulton, J. P.
1994-01-01
A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.
NASA Technical Reports Server (NTRS)
Workman, Gary L.; Wang, Morgan
1992-01-01
The recognition of materials properties still presents a number of problems for nondestructive testing in aerospace systems. This project attempts to utilize current capabilities in eddy current instrumentation, artificial intelligence, and robotics in order to provide insight into defining geometrical aspects of flaws in composite materials which are capable of being evaluated using eddy current inspection techniques.
Testing for Stray Current Corrosion in Earth Covered Magazines with EOP
2010-02-01
potential for Stray Current Corrosion BUILDING STRONG® Plot of Current Measurements 0 0.2 0.4 0.6 0.8 1 1.2 0 10 20 30 40 50 60 70 80 90 100 % I to Rebar m...magnitude as more current was directed to the reinforcing steel. Corrosion current was measured to the rebar probe placed above the location of...US Army Corps of Engineers BUILDING STRONG® Testing for Stray Current Corrosion in Earth Covered Magazines with EOP O. S. Marshall US Army
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min; Simpson, John
1993-01-01
Electromagnetic NDE techniques have in the past steered away from the use of ferromagnetic materials. Although their high permeabilities lead to increased field levels, the properties of ferrous elements in the presence of alternating magnetic fields are difficult to determine. In addition, their use leads to losses which can be minimized through the use of low conductivity ferrites. In fact, the eddy current probes which do incorporate ferromagnetic materials have focused on these losses and the shielding which can be obtained by surrounding a probe with a high permeability, conducting material. Eddy current probes enclosed in conducting and magnetic shields have been used to prevent the generated fields from interacting with materials in the vicinity of the probe, such as when testing near material boundaries. A recent invention has used ferromagnetic shielding to magnetically separate individual concentric eddy current probes in order to eliminate cross-talk between the probes so that simultaneous detection of different types of flaws at different depths can be achieved. In contrast to the previous uses of ferromagnetic materials purely as magnetic shields, an electromagnetic flaw detector recently developed at NASA Langley Research Center takes advantage of the flux focusing properties of a ferromagnetic mild steel in order to produce a simple, effective device for the non-destructive evaluation of conducting materials. The Flux Focusing Eddy Current Probe has been shown to accurately measure material thickness and fatigue damage. The straight forward flaw response of the probe makes the device ideal for rapid inspection of large structures, and has lead to its incorporation in a computer controlled search routine to locate fatigue crack tips and monitor experimental fatigue crack growth experiments.
Hapstack, M.; Talarek, T.R.; Zollinger, W.T.; Heckendorn, F.M. II; Park, L.R.
1994-02-15
An instrument carriage for inspection of piping comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, and an instrumentation arm carried by a shaft system running from the front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360[degree] about its axis. The instrument carriage uses servo motors and pressurized air cylinders for precise actuation of instrument components and precise, repeatable actuation of position control mechanisms. 8 figures.
Hapstack, Mark; Talarek, Ted R.; Zollinger, W. Thor; Heckendorn, II, Frank M.; Park, Larry R.
1994-01-01
An instrument carriage for inspection of piping comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, and an instrumentation arm carried by a shaft system running from the front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360.degree. about its axis. The instrument carriage uses servo motors and pressurized air cylinders for precise actuation of instrument components and precise, repeatable actuation of position control mechanisms.
Characterization of plasma processing induced charging damage to MOS devices
NASA Astrophysics Data System (ADS)
Ma, Shawming
1997-12-01
Plasma processing has become an integral part of the fabrication of integrated circuits and takes at least 30% of whole process steps since it offers advantages in terms of directionality, low temperature and process convenience. However, wafer charging during plasma processes is a significant concern for both thin oxide damage and profile distortion. In this work, the factors affecting this damage will be explained by plasma issues, device structure and oxide quality. The SPORT (Stanford Plasma On-wafer Real Time) charging probe was developed to investigate the charging mechanism of different plasma processes including poly-Si etching, resist ashing and PECVD. The basic idea of this probe is that it simulates a real device structure in the plasma environment and allows measurement of plasma induced charging voltages and currents directly in real time. This measurement is fully compatible with other charging voltage measurement but it is the only one to do in real-time. Effect of magnetic field induced plasma nonuniformity on spatial dependent charging is well understood by this measurement. In addition, the plasma parameters including ion current density and electron temperature can also be extracted from the probe's plasma I-V characteristics using a dc Langmuir probe like theory. It will be shown that the MOS device tunneling current from charging, the dependence on antenna ratio and the etch uniformity can all be predicted by using this measurement. Moreover, the real-time measurement reveals transient and electrode edge effect during processing. Furthermore, high aspect ratio pattern induced electron shading effects can also be characterized by the probe. On the oxide quality issue, wafer temperature during plasma processing has been experimentally shown to be critical to charging damage. Finally, different MOS capacitor testing methods including breakdown voltage, charge-to-breakdown, gate leakage current and voltage-time at constant current bias were compared to find the optimum method for charging device reliability testing.
Rifai, Damhuji; Abdalla, Ahmed N; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A
2017-03-13
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient.
ERIC Educational Resources Information Center
Cunningham, Corbin A.; Yassa, Michael A.; Egeth, Howard E.
2015-01-01
Previous work suggests that visual long-term memory (VLTM) is highly detailed and has a massive capacity. However, memory performance is subject to the effects of the type of testing procedure used. The current study examines detail memory performance by probing the same memories within the same subjects, but using divergent probing methods. The…
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Hill, Carrie S.; Turchi, Peter J.; Burton, Rodney L.; Messer, Sarah; Lovberg, Ralph H.; Hallock, Ashley K.
2013-01-01
Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.
van Wijck, Kim; Bessems, Babs AFM; van Eijk, Hans MH; Buurman, Wim A; Dejong, Cornelis HC; Lenaerts, Kaatje
2012-01-01
Background Increased intestinal permeability is an important measure of disease activity and prognosis. Currently, many permeability tests are available and no consensus has been reached as to which test is most suitable. The aim of this study was to compare urinary probe excretion and accuracy of a polyethylene glycol (PEG) assay and dual sugar assay in a double-blinded crossover study to evaluate probe excretion and the accuracy of both tests. Methods Gastrointestinal permeability was measured in nine volunteers using PEG 400, PEG 1500, and PEG 3350 or lactulose-rhamnose. On 4 separate days, permeability was analyzed after oral intake of placebo or indomethacin, a drug known to increase intestinal permeability. Plasma intestinal fatty acid binding protein and calprotectin levels were determined to verify compromised intestinal integrity after indomethacin consumption. Urinary samples were collected at baseline, hourly up to 5 hours after probe intake, and between 5 and 24 hours. Urinary excretion of PEG and sugars was determined using high-pressure liquid chromatography-evaporative light scattering detection and liquid chromatography-mass spectrometry, respectively. Results Intake of indomethacin increased plasma intestinal fatty acid-binding protein and calprotectin levels, reflecting loss of intestinal integrity and inflammation. In this state of indomethacin-induced gastrointestinal compromise, urinary excretion of the three PEG probes and lactulose increased compared with placebo. Urinary PEG 400 excretion, the PEG 3350/PEG 400 ratio, and the lactulose/rhamnose ratio could accurately detect indomethacin-induced increases in gastrointestinal permeability, especially within 2 hours of probe intake. Conclusion Hourly urinary excretion and diagnostic accuracy of PEG and sugar probes show high concordance for detection of indomethacin-induced increases in gastrointestinal permeability. This comparative study improves our knowledge of permeability analysis in man by providing a clear overview of both tests and demonstrates equivalent performance in the current setting. PMID:22888267
Electrical probe characteristic recovery by measuring only one time-dependent parameter
NASA Astrophysics Data System (ADS)
Costin, C.; Popa, G.; Anita, V.
2016-03-01
Two straightforward methods for recovering the current-voltage characteristic of an electrical probe are proposed. Basically, they consist of replacing the usual power supply from the probe circuit with a capacitor which can be charged or discharged by the probe current drained from the plasma. The experiment requires the registration of only one time-dependent electrical parameter, either the probe current or the probe voltage. The corresponding time-dependence of the second parameter, the probe voltage, or the probe current, respectively, can be calculated using an integral or a differential relation and the current-voltage characteristic of the probe can be obtained.
Micromachined Silicon Stimulating Probes with CMOS Circuitry for Use in the Central Nervous System
NASA Astrophysics Data System (ADS)
Tanghe, Steven John
1992-01-01
Electrical stimulation in the central nervous system is a valuable technique for studying neural systems and is a key element in the development of prostheses for deafness and other disorders. This thesis presents a family of multielectrode probe structures, fulfilling the need for chronic multipoint stimulation tools essential for interfacing to the highly complex neural networks in the brain. These probes are batch-fabricated on silicon wafers, employing photoengraving techniques to precisely control the electrode site and array geometries and to allow the integration of on-chip CMOS circuitry for signal multiplexing and stimulus current generation. Silicon micromachining is used to define the probe shapes, which have typical shank dimensions of 3 mm in length by 100 mu m in width by 15 μm in thickness. Each shank supports up to eight planar iridium oxide electrode sites capable of delivering charge densities in excess of 3 mC/cm^2 during current pulse stimulation. Three active probe circuits have been designed with varied complexity and capability. All three can deliver biphasic stimulus currents through 16 sites using only 5 external leads, and they are all compatible with the same external control system. The most complex design interprets site addresses and stimulus current amplitudes from 16-bit words shifted into the probe at 4 MHz. Sixteen on-chip, biphasic, 8-bit digital-to-analog converters deliver analog stimulus currents in the range of +/- 254 muA to any combination of electrode sites. These DACs exhibit full-scale internal linearity to better than +/-1/2 LSB and can be calibrated by varying the positive power supply voltage. The entire probe circuit dissipates only 80 muW from +/-5 V supplies when not delivering stimulus currents, it includes several safety features, and is testable from the input pads. Test results from the fabricated circuits indicate that they all function properly at clocking frequencies as high as 10 MHz, meeting or exceeding all design specifications. Probe structures without circuitry have been used for stimulation experiments in guinea pigs yielding excellent results.
An Ultrasonographic Periodontal Probe
NASA Astrophysics Data System (ADS)
Bertoncini, C. A.; Hinders, M. K.
2010-02-01
Periodontal disease, commonly known as gum disease, affects millions of people. The current method of detecting periodontal pocket depth is painful, invasive, and inaccurate. As an alternative to manual probing, an ultrasonographic periodontal probe is being developed to use ultrasound echo waveforms to measure periodontal pocket depth, which is the main measure of periodontal disease. Wavelet transforms and pattern classification techniques are implemented in artificial intelligence routines that can automatically detect pocket depth. The main pattern classification technique used here, called a binary classification algorithm, compares test objects with only two possible pocket depth measurements at a time and relies on dimensionality reduction for the final determination. This method correctly identifies up to 90% of the ultrasonographic probe measurements within the manual probe's tolerance.
Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps
NASA Technical Reports Server (NTRS)
Goekcen, Tahir; Alunni, Antonella I.
2016-01-01
This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.
In Vitro Comparison of a Novel Single Probe Dual-Energy Lithotripter to Current Devices.
Carlos, Evan C; Wollin, Daniel A; Winship, Brenton B; Jiang, Ruiyang; Radvak, Daniela; Chew, Ben H; Gustafson, Michael R; Simmons, W Neal; Zhong, Pei; Preminger, Glenn M; Lipkin, Michael E
2018-06-01
The LithoClast Trilogy is a novel single probe, dual-energy lithotripter with ultrasonic (US) vibration and electromagnetic impact forces. ShockPulse and LithoClast Select are existing lithotripters that also use a combination of US and mechanical impact energies. We compared the efficacy and tip motion of these devices in an in vitro setting. Begostones, in the ratio 15:3, were used in all trials. Test groups were Trilogy, ShockPulse, Select ultrasound (US) only, and Select ultrasound with pneumatic (USP). For clearance testing, a single investigator facile with each lithotripter fragmented 10 stones per device. For drill testing, a hands-free apparatus with a submerged balance was used to apply 1 or 2 lbs of pressure on a stone in contact with the device tip. High-speed photography was used to assess Trilogy and ShockPulse's probe tip motion. Select-USP was slowest and Trilogy fastest on clearance testing (p < 0.01). On 1 lbs drill testing, Select-US was slowest (p = 0.001). At 2 lbs, ShockPulse was faster than Select US (p = 0.027), but did not significantly outpace Trilogy nor Select-USP. At either weight, there was no significant difference between Trilogy and ShockPulse. During its US function, Trilogy's maximum downward tip displacement was 0.041 mm relative to 0.0025 mm with ShockPulse. Trilogy had 0.25 mm of maximum downward displacement during its impactor function while ShockPulse had 0.01 mm. Single probe dual-energy devices, such as Trilogy and ShockPulse, represent the next generation of lithotripters. Trilogy more efficiently cleared stone than currently available devices, which could be explained by its larger probe diameter and greater downward tip displacement during both US and impactor functions.
Natural Crack Sizing Based on Eddy Current Image and Electromagnetic Field Analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endo, H.; Uchimoto, T.; Takagi, T.
2006-03-06
An eddy current testing (ECT) system with multi-coil type probes is applied to size up cracks fabricated on austenite stainless plates. We have developed muti-channel ECT system to produce data as digital images. The probes consist of transmit-receive type sensors as elements to classify crack directions, working as two scan direction modes simultaneously. Template matching applied to the ECT images determines regions of interest in sizing up cracks. Finite element based inversion sizes up the crack depth from the measured ECT signal. The present paper demonstrates this approach for fatigue crack and stress corrosion cracking.
Eddy Current System for Material Inspection and Flaw Visualization
NASA Technical Reports Server (NTRS)
Bachnak, R.; King, S.; Maeger, W.; Nguyen, T.
2007-01-01
Eddy current methods have been successfully used in a variety of non-destructive evaluation applications including detection of cracks, measurements of material thickness, determining metal thinning due to corrosion, measurements of coating thickness, determining electrical conductivity, identification of materials, and detection of corrosion in heat exchanger tubes. This paper describes the development of an eddy current prototype that combines positional and eddy-current data to produce a C-scan of tested material. The preliminary system consists of an eddy current probe, a position tracking mechanism, and basic data visualization capability. Initial test results of the prototype are presented in this paper.
Rifai, Damhuji; Abdalla, Ahmed N.; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A.
2017-01-01
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient. PMID:28335399
Using polarized positrons to probe physics beyond the standard model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Furletova, Yulia; Mantry, Sonny
A high intensity polarized positron beam, as part of the JLAB 12 GeV program and the proposed electron-ion collider (EIC), can provide a unique opportunity for testing the Standard Model (SM) and probing for new physics. The combination of high luminosity with polarized electrons and positrons incident on protons and deuterons can isolate important effects and distinguish between possible new physics scenarios in a manner that will complement current experimental efforts. Here, a comparison of cross sections between polarized electron and positron beams will allow for an extraction of the poorly known weak neutral current coupling combination 2C 3u -more » C 3d and would complement the proposed plan for a precision extraction of the combination 2C 2u - C d at the EIC. Precision measurements of these neutral weak couplings would constrain new physics scenarios including Leptoquarks, R-parity violating supersymmetry, and electron and quark compositeness. The dependence of the charged current cross section on the longitudinal polarization of the positron beam will provide an independent probe to test the chiral structure of the electroweak interactions. A polarized positron can probe charged lepton flavor violation (CLFV) through a search for e + → τ + transitions in a manner that is independent and complementary to the proposed e - → τ - search at the EIC. A positron beam incident on an electron in a stationary nuclear target will also allow for a dark-photon (A') search via the annihilation process e + + e - → A' + γ.« less
Using polarized positrons to probe physics beyond the standard model
Furletova, Yulia; Mantry, Sonny
2018-05-25
A high intensity polarized positron beam, as part of the JLAB 12 GeV program and the proposed electron-ion collider (EIC), can provide a unique opportunity for testing the Standard Model (SM) and probing for new physics. The combination of high luminosity with polarized electrons and positrons incident on protons and deuterons can isolate important effects and distinguish between possible new physics scenarios in a manner that will complement current experimental efforts. Here, a comparison of cross sections between polarized electron and positron beams will allow for an extraction of the poorly known weak neutral current coupling combination 2C 3u -more » C 3d and would complement the proposed plan for a precision extraction of the combination 2C 2u - C d at the EIC. Precision measurements of these neutral weak couplings would constrain new physics scenarios including Leptoquarks, R-parity violating supersymmetry, and electron and quark compositeness. The dependence of the charged current cross section on the longitudinal polarization of the positron beam will provide an independent probe to test the chiral structure of the electroweak interactions. A polarized positron can probe charged lepton flavor violation (CLFV) through a search for e + → τ + transitions in a manner that is independent and complementary to the proposed e - → τ - search at the EIC. A positron beam incident on an electron in a stationary nuclear target will also allow for a dark-photon (A') search via the annihilation process e + + e - → A' + γ.« less
Using polarized positrons to probe physics beyond the standard model
NASA Astrophysics Data System (ADS)
Furletova, Yulia; Mantry, Sonny
2018-05-01
A high intensity polarized positron beam, as part of the JLAB 12 GeV program and the proposed electron-ion collider (EIC), can provide a unique opportunity for testing the Standard Model (SM) and probing for new physics. The combination of high luminosity with polarized electrons and positrons incident on protons and deuterons can isolate important effects and distinguish between possible new physics scenarios in a manner that will complement current experimental efforts. A comparison of cross sections between polarized electron and positron beams will allow for an extraction of the poorly known weak neutral current coupling combination 2C3u - C3d and would complement the proposed plan for a precision extraction of the combination 2C2u - Cd at the EIC. Precision measurements of these neutral weak couplings would constrain new physics scenarios including Leptoquarks, R-parity violating supersymmetry, and electron and quark compositeness. The dependence of the charged current cross section on the longitudinal polarization of the positron beam will provide an independent probe to test the chiral structure of the electroweak interactions. A polarized positron can probe charged lepton flavor violation (CLFV) through a search for e+ → τ+ transitions in a manner that is independent and complementary to the proposed e- → τ- search at the EIC. A positron beam incident on an electron in a stationary nuclear target will also allow for a dark-photon (A') search via the annihilation process e+ + e- → A' + γ.
Development of a Double Hemispherical Probe for Improved Space Plasma Measurements
NASA Astrophysics Data System (ADS)
Wang, X.; Samaniego, J. I.; Hsu, H.-W.; Horányi, M.; Wahlund, J.-E.; Ergun, R. E.; Bering, E. A.
2018-04-01
Langmuir probes have been widely used for space plasma measurements for decades. However, there are still challenges in the interpretation of their measurements. Due to the interaction of the ambient plasma with a spacecraft and an onboard probe itself, the local plasma conditions around the probe could be very different from the true ambient plasma of interest. These local plasma conditions are often anisotropic and/or inhomogeneous. Most of the Langmuir probes that are made of a single electrode have difficulties to remove these local plasma effects, introducing errors in the derived plasma characteristics. Directional probes are able to characterize anisotropic and inhomogeneous plasmas. The split Langmuir probe and the Segmented Langmuir Probe have been developed to characterize the plasma flow in the Earth's ionosphere. Here we introduce a new type of a directional Langmuir probe, the Double Hemispherical Probe (DHP), to improve the space plasma measurements in a broad range of scenarios: (a) low-density plasmas, (b) high surface-emission (photo and/or secondary electron emission) environments, (c) flowing plasmas, and (d) dust-rich plasma environments. The DHP consists of two identical hemispheres that are electrically insulated and swept with the same voltages simultaneously. The difference currents between the two hemispheres are used to characterize the anisotropic/inhomogeneous plasma conditions created around the probe, which will be then removed or minimized on the interpretation of their current-voltage curves. This paper describes the basic concept and design of the DHP sensor, as well as its initial results tested in the laboratory plasma environments.
Outer planet atmospheric entry probes - An overview of technology readiness
NASA Technical Reports Server (NTRS)
Vojvodich, N. S.; Reynolds, R. T.; Grant, T. L.; Nachtsheim, P. R.
1975-01-01
Entry probe systems for characterizing, by in situ measurements, the atmospheric properties, chemical composition, and cloud structure of the planets Saturn, Uranus, and Jupiter are examined from the standpoint of unique mission requirements, associated subsystem performance, and degree of commonality of design. Past earth entry vehicles (PAET) and current planetary spacecraft (Pioneer Venus probes and Viking lander) are assessed to identify the extent of potential subsystem inheritance, as well as to establish the significant differences, in both form and function, relative to outer planet requirements. Recent research results are presented and reviewed for the most critical probe technology areas, including: science accommodation, telecommunication, and entry heating and thermal protection. Finally presented is a brief discussion of the use of decision analysis techniques for quantifying various probe heat-shield test alternatives and performance risk.
Overview of recent aero-optics flight tests
NASA Technical Reports Server (NTRS)
Otten, L. J., III
1980-01-01
A chronological overview of aero-optics test flights is presented highlighting the objectives and conclusions from the tests. Flight tests performed in coordination with the PRESS reentry observation missions and the ALL Cycle 2 laser propagation and tracking demonstrations are described addressing the identification and quantification of distortion phenomena. Finally, current aero-optics flight investigations of an atmospheric turbulence probe are briefly discussed.
SPRITE: A TPS Test Bed for Ground and Flight
NASA Technical Reports Server (NTRS)
Prabhu, Dinesh K.; Agrawal, Parul; Peterson, Keith; Swanson, Gregory; Skokova, Kristina; Mangini, Nancy; Empey, Daniel M.; Gorbunov, Sergey; Venkatapathy, Ethiraj
2012-01-01
Engineers in the Entry Systems and Technology Division at NASA Ames Research Center developed a fully instrumented, small atmospheric entry probe called SPRITE (Small Probe Reentry Investigation for TPS Engineering). SPRITE, conceived as a flight test bed for thermal protection materials, was tested at full scale in an arc-jet facility so that the aerothermal environments the probe experiences over portions of its flight trajectory and in the arc-jet are similar. This ground-to-flight traceability enhances the ability of mission designers to evaluate margins needed in the design of thermal protection systems (TPS) of larger scale atmospheric entry vehicles. SPRITE is a 14-inch diameter, 45 deg. sphere-cone with a conical aftbody and designed for testing in the NASA Ames Aerodynamic Heating Facility (AHF). The probe is a two-part aluminum shell with PICA (phenolic impregnated carbon ablator) bonded on the forebody and LI-2200 (Shuttle tile material) bonded to the aftbody. Plugs with embedded thermocouples, similar to those installed in the heat shield of the Mars Science Laboratory (MSL), and a number of distributed sensors are integrated into the design. The data from these sensors are fed to an innovative, custom-designed data acquisition system also integrated with the test article. Two identical SPRITE models were built and successfully tested in late 2010-early 2011, and the concept is currently being modified to enable testing of conformable and/or flexible materials.
A compact, smart Langmuir Probe control module for MAST-Upgrade
NASA Astrophysics Data System (ADS)
Lovell, J.; Stephen, R.; Bray, S.; Naylor, G.; Elmore, S.; Willett, H.; Peterka, M.; Dimitrova, M.; Havranek, A.; Hron, M.; Sharples, R.
2017-11-01
A new control module for the MAST-Upgrade Langmuir Probe system has been developed. It is based on a Xilinx Zynq FPGA, which allows for excellent configurability and ease of retrieving data. The module is capable of arbitrary bias voltage waveform generation, and digitises current and voltage readings from 16 probes. The probes are biased and measured one at a time in a time multiplexed fashion, with the multiplexing sequence completely configurable. In addition, simultaneous digitisation of the floating potential of all unbiased probes is possible. A suite of these modules, each coupled with a high voltage amplifier, enables biasing and digitisation of 640 Langmuir Probes in the MAST-Upgrade Super-X divertor. The system has been successfully tested on the York Linear Plasma Device and on the COMPASS tokamak. It will be installed on MAST-Upgrade ready for operations in 2018.
A versatile and reconfigurable setup for all-terahertz time-resolved pump-probe spectroscopy.
Elezzabi, A Y; Maraghechi, P
2012-05-01
A versatile optical setup for all-terahertz (THz) time resolved pump-probe spectroscopy was designed and tested. By utilizing a dual THz pulse generator emitter module, independent and synchronized THz radiation pump and probe pulses were produced, thus eliminating the need for THz beam splitters and the limitations associated with their implementation. The current THz setup allows for precise control of the electric fields splitting ratio between the THz radiation pump and probe pulses, as well as in-phase, out-of-phase, and polarization dependent pump-probe spectroscopy. Since the present THz pump-probe setup does not require specialized THz radiation optical components, such as phase shifters, polarization rotators, or wide bandwidth beam splitters, it can be easily implemented with minimal alterations to a conventional THz time domain spectroscopy system. The present setup is valuable for studying the time dynamics of THz coherent phenomena in solid-state, chemical, and biological systems.
NASA Technical Reports Server (NTRS)
Namkung, M.; Fulton, J. P.; Wincheski, B.; Clendenin, C. G.
1993-01-01
A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles which necessitates automation of the whole process. If the rate of crack growth can be determined the experimenter can vary externally controlled parameters such as load level, load cycle frequency and so on. Hence, knowledge of the precise location of the crack tip at any given time is very valuable. One technique currently available for measuring fatigue crack length is the DC potential drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another approach is to digitize an optical image of the test specimen surface and then apply a pattern recognition technique to locate the crack tip, but this method is still under development. The present work is an initial study on applying eddy current-type probes to monitoring fatigue crack growth. The performance of two types of electromagnetic probes, a conventional eddy current probe and a newly developed self-nulling probe, was evaluated for the detection characteristics at and near the tips of fatigue cracks. The scan results show that the latter probe provides a very well defined local maximum in its output in the crack tip region suggesting the definite possibility of precisely locating the tip, while the former provides a somewhat ambiguous distribution of the sensor output in the same region. The paper is organized as follows: We start by reviewing the design and performance characteristics of the self-nulling probe and then describe the scan results which demonstrate the basic properties of the self-nulling probe. Next, we provide a brief description of the software developed for tracing a simulated crack and give a brief discussion of the main results of the test. The final section summarizes the major accomplishments of the present work and the elements of the future R&D needs.
Ullrich, Thomas; Ermantraut, Eugen; Schulz, Torsten; Steinmetzer, Katrin
2012-01-01
Background State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests. Methodology and Principal Findings The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique. Conclusions and Significance The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution for real time monitoring of binding events of fluorescently labelled ligands to surface immobilized probes. With the model assay for the detection of human immunodeficiency virus type 1 and 2 (HIV 1/2), we have been able to observe the amplification kinetics of five targets simultaneously and accommodate two additional hybridization controls with a simple instrument set-up. The ability to accommodate multiple controls and targets into a single assay and to perform the assay on simple and robust instrumentation is a prerequisite for the development of novel molecular point of care tests. PMID:22539973
Combination probes for stagnation pressure and temperature measurements in gas turbine engines
NASA Astrophysics Data System (ADS)
Bonham, C.; Thorpe, S. J.; Erlund, M. N.; Stevenson, R. J.
2018-01-01
During gas turbine engine testing, steady-state gas-path stagnation pressures and temperatures are measured in order to calculate the efficiencies of the main components of turbomachinery. These measurements are acquired using fixed intrusive probes, which are installed at the inlet and outlet of each component at discrete point locations across the gas-path. The overall uncertainty in calculated component efficiency is sensitive to the accuracy of discrete point pressures and temperatures, as well as the spatial sampling across the gas-path. Both of these aspects of the measurement system must be considered if more accurate component efficiencies are to be determined. High accuracy has become increasingly important as engine manufacturers have begun to pursue small gains in component performance, which require efficiencies to be resolved to within less than ± 1% . This article reports on three new probe designs that have been developed in a response to this demand. The probes adopt a compact combination arrangement that facilitates up to twice the spatial coverage compared to individual stagnation pressure and temperature probes. The probes also utilise novel temperature sensors and high recovery factor shield designs that facilitate improvements in point measurement accuracy compared to standard Kiel probes used in engine testing. These changes allow efficiencies to be resolved within ± 1% over a wider range of conditions than is currently achievable with Kiel probes.
Electronic thermometry in tunable tunnel junction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maksymovych, Petro
A tunable tunnel junction thermometry circuit includes a variable width tunnel junction between a test object and a probe. The junction width is varied and a change in thermovoltage across the junction with respect to the change in distance across the junction is determined. Also, a change in biased current with respect to a change in distance across the junction is determined. A temperature gradient across the junction is determined based on a mathematical relationship between the temperature gradient, the change in thermovoltage with respect to distance and the change in biased current with respect to distance. Thermovoltage may bemore » measured by nullifying a thermoelectric tunneling current with an applied voltage supply level. A piezoelectric actuator may modulate the probe, and thus the junction width, to vary thermovoltage and biased current across the junction. Lock-in amplifiers measure the derivatives of the thermovoltage and biased current modulated by varying junction width.« less
Bunker probe: A plasma potential probe almost insensitive to its orientation with the magnetic field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costea, S., E-mail: stefan.costea@uibk.ac.at; Schneider, B. S.; Schrittwieser, R.
Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic structure, or magnetic field reconnection. In this perspective, we have developed a plasma potential probe (named Bunker probe) based on the principle of the ion sensitive probe but almost insensitive to its orientation with the totalmore » magnetic field. Therefore it can be used to measure the plasma potential inside fusion devices, especially in regions with complex magnetic field topology. Experimental results are presented and compared with Ball-Pen probe measurements taken under identical conditions. We have observed that the floating potential of the Bunker probe is indeed little affected by its orientation with the magnetic field for angles ranging from 90° to 30°, in contrast to the Ball-Pen probe whose floating potential decreases towards that of a Langmuir probe if not properly aligned with the magnetic field.« less
Implications of contamination and surface area ratios for Langmuir probe diagnostics on CubeSats
NASA Astrophysics Data System (ADS)
Suresh, P.; Swenson, C.
2009-12-01
Theories describing the current collected by a biased probe under various conditions are necessary for such observation to be used to accurately determine plasma properties. Langmuir probes are routinely used on spacecraft to measure plasma parameters such as density, temperature, and vehicle charging. The collected current is a function of the potential between the surrounding plasma and probe surface. There have been both observations of and concepts for unaccounted variations of this potential which limit the application of Langmuir probe theory for determining plasma properties. These variations occur due to spatial variations of the work function across the probe surface due to non-uniformity of the crystalline surface properties and surface contamination of the probe. Currently we do not have theoretical expressions which consider these factors as first principles in their derivation. In the event of these surface potential variations, the analysis of the plasma using the currently available theories of the Langmuir probe yield erroneous results. We present a theory which models the current as a function of the surface potential variations. Another consideration for Langmuir probes on CubeSats is the ratio of the probe area to the return current collection area. If the area ratio is unfavorable this can also lead to erroneous results in the interpretation of observations. A mathematical formulation of the current collected by the probe for contaminated surfaces is presented and compared with data from a Langmuir probe flown on a sounding rocket mission. The implications of using Langmuir probes on CubeSats given the engineering limitations of probe cleanliness and area ratios are reviewed.
Evaluation of eddy-current proximity devices for measuring thin potassium film thicknesses
NASA Technical Reports Server (NTRS)
Asadourian, A. S.
1972-01-01
Two eddy current proximity probe systems were tested over a range of 0 to 508 micrometers (0 to 20 mils) of simulated potassium film thicknesses for simulated temperatures of 66 C (150 F), 232 C (450 F), and 666 C (1230 F). The results of short time calibration tests are presented. Instrument drift was a problem throughout the testing and, without correction, may limit the use of such systems to short periods of time. Additional development will be required prior to their being usable as practical instrumentation systems.
Thermal Protection System Development, Testing and Qualification
NASA Astrophysics Data System (ADS)
Venkatapathy, Ethiraj; Arnold, James; Laub, B.; Hartman, G. J.
The science community currently has interest in planetary entry probe missions to improve our understanding of the atmospheres of Saturn and Venus [1,2]. As in the case of the Galileo entry probe, such data are critical to the understanding of not only the individual planets but also to further knowledge regarding the formation of the solar system. It is believed that Saturn probes to depths corresponding to 10 bars will be sufficient [1] to provide the desired scientific data. The heating rates for the "shallow" Saturn probes and Venus are in the range of 2 - 5KW/cm2 . It is clear that new, mid-density Thermal Protection System (TPS) materials for such probes can be mission-enabling for mass efficiency [3] and also make the use of smaller vehicles possible from advancements in scientific instrumentation [4]. Past consideration of new Jovian multiprobe missions has been considered problematic without the Giant Planet Arcjet Facility that was used to qualify Carbon Phenolic for the Galileo Probe. This paper describes emerging TPS technology and the proposed use of an affordable, small 5 MW arc jet that can be used for TPS development in test gases appropriate for the aforementioned, new planetary probe applications. Emerging TPS technologies of interest include a mid-density, chopped molded carbon phenolic (CMCP) material around 0.8g/cc and a densified variant of phenolic impregnated carbon ablator (PICA) around 0.5g/cc. The small 5 MW arc jet facility, called the Development Arcjet Facility (DAF) and the methodology of testing TPS, both based on previous work, are discussed. Finally, the applications to Earth entry appropriate to speeds greater than lunar return (11km/s) are discussed as will facility-to-facility validation using air as a test gas. The use of other facilities for development, qualification and certification of TPS for Saturn and Venus is also discussed. [1] Atreya, S. K., et. al. Formation of Giant Planets and Their Atmospheres: Entry Probes for Saturn and Beyond; 5 th International Planetary Probe Workshop, June 25-29, Bordeaux, France. [2] Baines, K. H, et. al, Exploring Venus with Balloons: Science Objectives and Mission Architectures. 5 th International Planetary Probe Workshop, June 25-29 Bordeaux, France.
Open-target sparse sensing of biological agents using DNA microarray
2011-01-01
Background Current biosensors are designed to target and react to specific nucleic acid sequences or structural epitopes. These 'target-specific' platforms require creation of new physical capture reagents when new organisms are targeted. An 'open-target' approach to DNA microarray biosensing is proposed and substantiated using laboratory generated data. The microarray consisted of 12,900 25 bp oligonucleotide capture probes derived from a statistical model trained on randomly selected genomic segments of pathogenic prokaryotic organisms. Open-target detection of organisms was accomplished using a reference library of hybridization patterns for three test organisms whose DNA sequences were not included in the design of the microarray probes. Results A multivariate mathematical model based on the partial least squares regression (PLSR) was developed to detect the presence of three test organisms in mixed samples. When all 12,900 probes were used, the model correctly detected the signature of three test organisms in all mixed samples (mean(R2)) = 0.76, CI = 0.95), with a 6% false positive rate. A sampling algorithm was then developed to sparsely sample the probe space for a minimal number of probes required to capture the hybridization imprints of the test organisms. The PLSR detection model was capable of correctly identifying the presence of the three test organisms in all mixed samples using only 47 probes (mean(R2)) = 0.77, CI = 0.95) with nearly 100% specificity. Conclusions We conceived an 'open-target' approach to biosensing, and hypothesized that a relatively small, non-specifically designed, DNA microarray is capable of identifying the presence of multiple organisms in mixed samples. Coupled with a mathematical model applied to laboratory generated data, and sparse sampling of capture probes, the prototype microarray platform was able to capture the signature of each organism in all mixed samples with high sensitivity and specificity. It was demonstrated that this new approach to biosensing closely follows the principles of sparse sensing. PMID:21801424
Validation of Afterbody Aeroheating Predictions for Planetary Probes: Status and Future Work
NASA Technical Reports Server (NTRS)
Wright, Michael J.; Brown, James L.; Sinha, Krishnendu; Candler, Graham V.; Milos, Frank S.; Prabhu, DInesh K.
2005-01-01
A review of the relevant flight conditions and physical models for planetary probe afterbody aeroheating calculations is given. Readily available sources of afterbody flight data and published attempts to computationally simulate those flights are summarized. A current status of the application of turbulence models to afterbody flows is presented. Finally, recommendations for additional analysis and testing that would reduce our uncertainties in our ability to accurately predict base heating levels are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.
2016-02-29
This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within themore » exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).« less
Eddy current probe and method for flaw detection in metals
Watjen, J.P.
1987-06-23
A flaw detecting system is shown which includes a probe having a pair of ferrite cores with in-line gaps in close proximity to each other. An insulating, non-magnetic, non-conducting holder fills the gaps and supports the ferrite cores in a manner such that the cores form a generally V-shape. Each core is provided with an excitation winding and a detection winding. The excitation windings are connected in series or parallel with an rf port for connection thereof to a radio frequency source. The detection windings, which are differentially wound, are connected in series circuit to a detector port for connection to a voltage measuring instrument. The ferrite cores at the in-line gaps directly engage the metal surface of a test piece, and the probe is scanned along the test piece. In the presence of a flaw in the metal surface the detection winding voltages are unbalanced, and the unbalance is detected by the voltage measuring instrument. The insulating holder is provided with a profile which conforms to that of a prominent feature of the test piece to facilitate movement of the probe along the feature, typically an edge or a corner. 9 figs.
Eddy current probe and method for flaw detection in metals
Watjen, John P.
1987-06-23
A flaw detecting system is shown which includes a probe having a pair of ferrite cores with in-line gaps in close proximity to each other. An insulating, non-magnetic, non-conducting holder fills the gaps and supports the ferrite cores in a manner such that the cores form a generally V-shape. Each core is provided with an excitation winding and a detection winding. The excitation windings are connected in series or parallel with an rf port for connection thereof to a radio frequency source. The detection windings, which are differentially wound, are connected in series circuit to a detector port for connection to a voltage measuring instrument. The ferrite cores at the in-line gaps directly engage the metal surface of a test piece, and the probe is scanned along the test piece. In the presence of a flaw in the metal surface the detection winding voltages are unbalanced, and the unbalance is detected by the voltage measuring instrument. The insulating holder is provided with a profile which conforms to that of a prominent feature of the test piece to facilitate movement of the probe along the feature, typically an edge or a corner.
Melting probes revisited - Ice penetration experiments under Mars surface pressure conditions
NASA Astrophysics Data System (ADS)
Kömle, Norbert I.; Tiefenbacher, Patrick; Weiss, Peter; Bendiukova, Anastasiia
2018-07-01
Melting probes as vehicles to explore terrestrial ice sheets have been designed and applied successfully since the early 1960's. Later on, in the 1990's, various proposals were made to apply such probes also as a means to explore ice sheets on other bodies of the solar system, e.g. Jupiter's icy satellite Europa or the ice caps of Mars. For this type of subsurface probes the name cryobot has become common. We review both early developments and more recent efforts to develop probes for application in planetary environments, i.e. under low pressures and low temperatures. The current state of art as well as the pros and cons of the different concepts hitherto considered are described. While many tests with various probes have been done in terrestrial environments, experiments under low surface pressure conditions are rare. Therefore, we report here on lab tests with a simple melting probe under the range of pressure and temperature conditions that would be encountered on the surface of Mars and compare them with corresponding tests under a much lower gas pressure, possibly representative for icy satellites. The contribution of evaporation during the melting and its variation with surface pressure is also considered. All surface pressure measurements that have been performed on Mars up to now indicate a surface pressure above the water triple point pressure (612 Pa). This means that water ice always transforms into the liquid phase when warmed up to 0°C, before it evaporates into the ambient atmosphere. The temporary existence of the liquid phase around the heated tip of the cryobot allows good thermal conductance between probe and surrounding ice, which is an important pre-requisite for efficient melt penetration. Our experiments indicate that under all possible Mars surface pressures the liquid phase is present when the probe is heated up. This finding confirms experimentally that a probe as it was proposed by Paige (1992) for in situ exploration of the Mars north polar layers would work in the expected way, although the penetration velocity must be expected be lower than under Earth pressure conditions. A test with the same probe, but under an almost two orders of magnitude lower gas pressure than on Mars, still indicates the temporary existence of the liquid phase in the contact region between the probe and the surrounding ice.
Zooming in on neutrino oscillations with DUNE
NASA Astrophysics Data System (ADS)
Srivastava, Rahul; Ternes, Christoph A.; Tórtola, Mariam; Valle, José W. F.
2018-05-01
We examine the capabilities of the DUNE experiment as a probe of the neutrino mixing paradigm. Taking the current status of neutrino oscillations and the design specifications of DUNE, we determine the experiment's potential to probe the structure of neutrino mixing and C P violation. We focus on the poorly determined parameters θ23 and δC P and consider both two and seven years of run. We take various benchmarks as our true values, such as the current preferred values of θ23 and δC P, as well as several theory-motivated choices. We determine quantitatively DUNE's potential to perform a precision measurement of θ23, as well as to test the C P violation hypothesis in a model-independent way. We find that, after running for seven years, DUNE will make a substantial step in the precise determination of these parameters, bringing to quantitative test the predictions of various theories of neutrino mixing.
Effect of Background Pressure on the Performance and Plume of the HiVHAc Hall Thruster
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Haag, Thomas
2013-01-01
During the Single String Integration Test of the NASA HiVHAc Hall thruster, a number of plasma diagnostics were implemented to study the effect of varying facility background pressure on thruster operation. These diagnostics include thrust stand, Faraday probe, ExB probe, and retarding potential analyzer. The test results indicated a rise in thrust and discharge current with background pressure. There was also a decrease in ion energy per charge, an increase in multiply-charged species production, a decrease in plume divergence, and a decrease in ion beam current with increasing background pressure. A simplified ingestion model was applied to determine the maximum acceptable background pressure for thrust measurement. The maximum acceptable ingestion percentage was found to be around 1%. Examination of the diagnostics results suggest the ionization and acceleration zones of the thruster were shifting upstream with increasing background pressure.
Nieuwenhuijsen, Karen; Hulshof, Carel T; Sluiter, Judith K
2018-07-01
To study the influence of the presentation of results of a preventive medical examination on risk perception and willingness to seek help for work-related fatigue or being overweight. A factorial design experiment was conducted, presenting workers (n = 82) with vignettes including eight scenarios of test results with and without an emphasis on the risk of a current or future health condition or a probe to seek help. Participants rated perceived risk and willingness to seek help (0-100 Visual Analogue Scale) as if these were their own results. Differences were tested with paired-sample t-tests. In scenarios emphasizing the risk of a current or future disorder, participants perceived higher risk and were more willing to seek help (p-values < .00). Slightly higher willingness to seek help scores was observed in all scenarios that included probes (p < .00). Risk perception and willingness to seek help of workers participating in a preventive medical examination were higher when they were told that the test results indicate a risk of a current or future disorder and after being advised to seek help. Healthcare providers should take the potential effects on risk perception and help-seeking into account in preventive settings. Copyright © 2018. Published by Elsevier B.V.
Duan, Zhiqiang; Zhang, Chunxian; Qiao, Yuchun; Liu, Fengjuan; Wang, Deyan; Wu, Mengfan; Wang, Ke; Lv, Xiaoxia; Kong, Xiangmu; Wang, Hua
2017-08-01
A polyhydric polymer-functionalized probe with enhanced aqueous solubility was designed initially by coupling 1-pyrenecarboxyaldehyde (Pyr) onto poly(vinyl alcohol) (PVA) via the one-step condensation reaction. Polyhydric PVA polymer chains could facilitate the Pyr fluorophore with largely improved aqueous solubility and especially strong cyan fluorescence. Importantly, the fluorescence of the PVA-Pyr probes could thereby be quenched specifically by Fe 3+ ions through the strong PVA-Fe 3+ interaction triggering the polymeric probe aggregation. Furthermore, a test strips-based fluorimetric method was developed with the stable and uniform probe distribution by taking advantage of the unique film-forming ability and the depression capacity of "coffee-stain" effects of PVA matrix. The as-developed test strips could allow for the rapid and visual detections of Fe 3+ ions simply by a dipping way, showing a linear concentration range of 5.00-300μM, with the detection limit of 0.73μM. Moreover, the proposed method was applied to the evaluation of Fe 3+ ions in natural water samples, showing the analysis performances better or comparable to those of current detection techniques. This test strips-based fluorimetric strategy promises the extensive applications for the rapid on-site monitoring of Fe 3+ ions in environmental water and the outdoor finding of the potential iron mines. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Fengqin; Xu, Yanmei; Yu, Xiang; Yu, Zhigang; He, Xunjun; Ji, Hongrui; Dong, Jinghao; Song, Yongbin; Yan, Hong; Zhang, Guiling
2016-08-15
One "signal on" electrochemical sensing strategy was constructed for the detection of a specific hepatitis B virus (HBV) gene sequence based on the protection-displacement-hybridization-based (PDHB) signaling mechanism. This sensing system is composed of three probes, one capturing probe (CP) and one assistant probe (AP) which are co-immobilized on the Au electrode surface, and one 3-methylene blue (MB) modified signaling probe (SP) free in the detection solution. One duplex are formed between AP and SP with the target, a specific HBV gene sequence, hybridizing with CP. This structure can drive the MB labels close to the electrode surface, thereby producing a large detection current. Two electrochemical testing techniques, alternating current voltammetry (ACV) and cyclic voltammetry (CV), were used for characterizing the sensor. Under the optimized conditions, the proposed sensor exhibits a high sensitivity with the detection limit of ∼5fM for the target. When used for the discrimination of point mutation, the sensor also features an outstanding ability and its peculiar high adjustability. Copyright © 2016 Elsevier B.V. All rights reserved.
Characterizing the performance of eddy current probes using photoinductive field-mapping
NASA Astrophysics Data System (ADS)
Moulder, John C.; Nakagawa, Norio
1992-12-01
We present a new method for characterizing the performance of eddy current probes by mapping their electromagnetic fields. The technique is based on the photoinductive effect, the change in the impedance of an eddy current probe induced by laser heating of the material under the probe. The instrument we developed maps a probe's electric field distribution by scanning an infrared laser beam over a thin film of gold lying underneath the probe. Measurements of both photoinductive signals and flaw signals for a series of similar probes demonstrates that the impedance change caused by an electrical-discharge-machined notch or a fatigue crack is proportional to the strength of the photoinductive signal. Thus, photoinductive measurements can supplant the use of artifact standards to calibrate eddy current probes.
Langmuir-Probe Measurements in Flowing-Afterglow Plasmas
NASA Technical Reports Server (NTRS)
Johnsen, R.; Shunko, E. V.; Gougousi, T.; Golde, M. F.
1994-01-01
The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.
NASA Astrophysics Data System (ADS)
Gur, David; Zheng, Bin; Dhurjaty, Sreeram; Wolfe, Gene; Fradin, Mary; Weil, Richard; Sumkin, Jules; Zuley, Margarita
2009-02-01
In our previous study, we reported on the development and preliminary testing of a prototype resonance electrical impedance spectroscopy (REIS) system with a pair of probes. Although our pilot study on 150 young women ranging from 30 to 50 years old indicated the feasibility of using REIS output sweep signals to classify between the women who had negative examinations and those who would ultimately be recommended for biopsy, the detection sensitivity was relatively low. To improve performance when using REIS technology, we recently developed a new multi-probe based REIS system. The system consists of a sensor module box that can be easily lifted along a vertical support device to fit women of different height. Two user selectable breast placement "cups" with different curvatures are included in the system. Seven probes are mounted on each of the cups on opposing sides of the sensor box. By rotating the sensor box, the technologist can select the detection sensor cup that better fits the breast size of the woman being examined. One probe is mounted in the cup center for direct contact with the nipple and the other six probes are uniformly distributed along an outside circle to enable contact with six points on the outer and inner breast skin surfaces. The outer probes are located at a distance of 60mm away from the center (nipple) probe. The system automatically monitors the quality of the contact between the breast surface and each of the seven probes and data acquisition can only be initiated when adequate contact is confirmed. The measurement time for each breast is approximately 15 seconds during which time the system records 121 REIS signal sweep outputs generated from 200 KHz to 800 KHz at 5 KHz increments for all preselected probe pairs. Currently we are measuring 6 pairs between the center probe and each of six probes located on the outer circle as well as two pairs between probe pairs on the outer circle. This new REIS system has been installed in our clinical breast imaging facility. We are conducting a prospective study to assess performance when using this REIS system under an approved IRB protocol. Over 200 examinations have been conducted to date. Our experience showed that this new REIS system was easy to operate and the REIS examination was fast and considered "comfortable" by examinees since the women presses her breast into the cup herself without any need for forced breast compression, and all but a few highly sensitive women have any sensation of an electrical current during the measurement.
Simultaneous Optical Measurements of Axial and Tangential Steady-State Blade Deflections
NASA Technical Reports Server (NTRS)
Kurkov, Anatole P.; Dhadwal, Harbans S.
1999-01-01
Currently, the majority of fiber-optic blade instrumentation is being designed and manufactured by aircraft-engine companies for their own use. The most commonly employed probe for optical blade deflection measurements is the spot probe. One of its characteristics is that the incident spot on a blade is not fixed relative to the blade, but changes depending on the blade deformation associated with centrifugal and aerodynamic loading. While there are geometrically more complicated optical probe designs in use by different engine companies, this paper offers an alternate solution derived from a probe-mount design feature that allows one to change the probe axial position until the incident spot contacts either a leading or a trailing edge. By tracing the axial position of either blade edge one is essentially extending the deflection measurement to two dimensions, axial and tangential. The blade deflection measurements were obtained during a wind tunnel test of a fan prototype.
High-Resolution and Frequency, Printed Miniature Magnetic Probes
NASA Astrophysics Data System (ADS)
Prager, James; Ziemba, Timothy; Miller, Kenneth; Picard, Julian
2013-10-01
Eagle Harbor Technologies, Inc. (EHT) is developing a technique to significantly reduce the cost and development time of producing magnetic field diagnostics. EHT is designing probes that can be printed on flexible PCBs thereby allowing for extremely small coils to be produced while essentially eliminating the time to wind the coils. The coil size can be extremely small when coupled with the EHT Hybrid Integrator, which is capable of high bandwidth measurements over short and long pulse durations. This integrator is currently being commercialized with the support of a DOE SBIR. Additionally, the flexible PCBs allow probes to be attached to complex surface and/or probes that have a complex 3D structure to be designed and fabricated. During the Phase I, EHT will design and construct magnetic field probes on flexible PCBs, which will be tested at the University of Washington's HIT-SI experiment and in EHT's material science plasma reactor. Funding provided by DOE SBIR/STTR Program.
A thermal shield concept for the Solar Probe mission
NASA Technical Reports Server (NTRS)
Miyake, Robert N.; Millard, Jerry M.; Randolph, James E.
1991-01-01
The Solar Probe spacecraft will travel to within 4 solar radii of the sun's center while performing a variety of fundamental experiments in space physics. Exposure to 2900 earth suns (400 W/sq cm) at perihelion imposes severe thermal and material demands on a solar shield system designed to protect the payload that will reside within the shield's shadow envelope or umbra. The design of the shield subsystem is a thermal/materials challenge requiring new technology development. While currently in the preproject study phase, anticipating a 1995 project start, shield preliminary design efforts are currently underway. This paper documents the current status of the mission concept, the materials issues, the configuration concept for the shield subsystem, the current configuration studies performed to date, and the required material testing to provide a database to support a design effort required to develop the shield subsystem.
Freeform metrology using subaperture stitching interferometry
NASA Astrophysics Data System (ADS)
Supranowitz, Chris; Lormeau, Jean-Pierre; Maloney, Chris; Murphy, Paul; Dumas, Paul
2016-11-01
As applications for freeform optics continue to grow, the need for high-precision metrology is becoming more of a necessity. Currently, coordinate measuring machines (CMM) that implement touch probes or optical probes can measure the widest ranges of shapes of freeform optics, but these measurement solutions often lack sufficient lateral resolution and accuracy. Subaperture stitching interferometry (SSI™) extends traditional Fizeau interferometry to provide accurate, high-resolution measurements of flats, spheres, and aspheres, and development is currently on-going to enable measurements of freeform surfaces. We will present recent freeform metrology results, including repeatability and cross-test data. We will also present MRF® polishing results where the stitched data was used as the input "hitmap" to the deterministic polishing process.
Experimental Studies of the Effect of Intent Information on Cockpit Traffic Displays
NASA Technical Reports Server (NTRS)
Barhydt, Richard; Hansman, R. John
1997-01-01
Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: Position, Rate, Commanded State, and FMS (Flight Management System)-Path. The current TCAS (traffic collision avoidance systems) Display, which shows altitude rate in addition to current position and altitude, was used as a baseline and represents the lowest level of intent. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An initial experiment was run on the MIT (Massachusetts Institute of Technology) Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.
Development of Simple Designs of Multitip Probe Diagnostic Systems for RF Plasma Characterization
Naz, M. Y.; Shukrullah, S.; Ghaffar, A.; Rehman, N. U.
2014-01-01
Multitip probes are very useful diagnostics for analyzing and controlling the physical phenomena occurring in low temperature discharge plasmas. However, DC biased probes often fail to perform well in processing plasmas. The objective of the work was to deduce simple designs of DC biased multitip probes for parametric study of radio frequency plasmas. For this purpose, symmetric double probe, asymmetric double probe, and symmetric triple probe diagnostic systems and their driving circuits were designed and tested in an inductively coupled plasma (ICP) generated by a 13.56 MHz radio frequency (RF) source. Using I-V characteristics of these probes, electron temperature, electron number density, and ion saturation current was measured as a function of input power and filling gas pressure. An increasing trend was noticed in electron temperature and electron number density for increasing input RF power whilst a decreasing trend was evident in these parameters when measured against filling gas pressure. In addition, the electron energy probability function (EEPF) was also studied by using an asymmetric double probe. These studies confirmed the non-Maxwellian nature of the EEPF and the presence of two groups of the energetic electrons at low filling gas pressures. PMID:24683326
Probing possible decoherence effects in atmospheric neutrino oscillations.
Lisi, E; Marrone, A; Montanino, D
2000-08-07
It is shown that the results of the Super-Kamiokande atmospheric neutrino experiment, interpreted in terms of nu(mu)<-->nu(tau) flavor transitions, can probe possible decoherence effects induced by new physics (e.g., by quantum gravity) with high sensitivity, supplementing current laboratory tests based on kaon oscillations and on neutron interferometry. By varying the (unknown) energy dependence of such effects, one can either obtain strong limits on their amplitude or use them to find an unconventional solution to the atmospheric nu anomaly based solely on decoherence.
Superconducting thin-film gyroscope readout for Gravity Probe-B
NASA Technical Reports Server (NTRS)
Lockhart, James M.; Cheung, W. Stephen; Gill, Dale K.
1987-01-01
The high-resolution gyroscope readout system for the Stanford Gravity Probe-B experiment, whose purpose is to measure two general relativistic precessions of gyroscopes in earth orbit, is described. In order to achieve the required resolution in angle (0.001 arcsec), the readout system combines high-precision mechanical fabrication and measurement techniques with superconducting thin-film technology, ultralow magnetic fields, and SQUID detectors. The system design, performance limits achievable with current technology, and the results of fabrication and laboratory testing to date are discussed.
Revolving Eddy-Current Probe Detects Cracks Near Rivets
NASA Technical Reports Server (NTRS)
Namkung, Min; Wincheski, Buzz; Fulton, James P.; Nath, Shridhar; Simpson, John
1995-01-01
Scanning eddy-current probe in circular pattern increases sensitivity with which probe indicates fatigue cracks and other defects in metal surfaces in vicinity of rivets. Technique devised to facilitate inspection of riveted joints in aircraft. Eddy-current probe in question described in "Electro-magnetic Flaw Detector Is Easier To Use" (LAR-15046).
Aluminum hydroxide coating thickness measurements and brushing tests on K West Basin fuel elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitner, A.L.
1998-09-11
Aluminum hydroxide coating thicknesses were measured on fuel elements stored in aluminum canisters in K West Basin using specially developed eddy current probes . The results were used to estimate coating inventories for MCO fuel,loading. Brushing tests successfully demonstrated the ability to remove the coating if deemed necessary prior to MCO loading.
Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary
NASA Technical Reports Server (NTRS)
Pachlhofer, Peter; Howard, Robert
1999-01-01
The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.
Flowpath evaluation and reconnaissance by remote field Eddy current testing (FERRET)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smoak, A.E.; Zollinger, W.T.
1993-12-31
This document describes the design and development of FERRET (Flowpath Evaluation and Reconnaisance by Remote-field Eddy current Testing). FERRET is a system for inspecting the steel pipes which carry cooling water to underground nuclear waste storage tanks. The FERRET system has been tested in a small scale cooling pipe mock-up, an improved full scale mock-up, and in flaw detection experiments. Early prototype designs of FERRET and the FERRET launcher (a device which inserts, moves, and retrieves probes from a piping system) as well as the field-ready design are discussed.
Characterization of DUT impedance in immunity test setups
NASA Astrophysics Data System (ADS)
Hassanpour Razavi, Seyyed Ali; Frei, Stephan
2016-09-01
Several immunity test procedures for narrowband radiated electromagnetic energy are available for automotive components. The ISO 11452 series describes the most commonly used test methods. The absorber line shielded enclosure (ALSE) is often considered as the most reliable method. However, testing with the bulk current injection (BCI) can be done with less efforts and is often preferred. As the test setup in both procedures is quite similar, there were several trials for finding appropriate modifications to the BCI in order to increase the matching to the ALSE. However, the lack of knowledge regarding the impedance of the tested component, makes it impossible to find the equivalent current to be injected by the BCI and a good match cannot be achieved. In this paper, three approaches are proposed to estimate the termination impedance indirectly by using different current probes.
Evaluation of the Self-Nulling Rotating Eddy Current Probe System
NASA Technical Reports Server (NTRS)
Hagemaier, Don; Rengel, Kent; Wincheski, Buzz; Namkung, Min
1999-01-01
In order to detect multi-site fatigue cracks located under flush-head rivets, automated eddy current equipment is required. To assure a reliable system, the eddy current probe must be centered easily over the installed rivets. To meet these requirements, the NDE Group at NASA LaRC developed the Self-Nulling Rotating Eddy Current Probe System (SNRECPS) which will be referred to as RPS in this document. The system was evaluated at the FAA, NDI Validation Center, in Albuquerque, New Mexico. The system was capable of detecting a 0.032 inch long crack with a 90/95% PoD. Further evaluations were conducted at Boeing in Long Beach, California. These evaluations included fatigue cracks and notches in a range from 0.025 to 0.100 inch long under flush-head aluminum rivets, and titanium or steel flush-head fasteners. The results of these tests are reported herein. Subsequently, the system was loaned to the USAF Structures Laboratory for the purpose of detecting and measuring short cracks under flush-head rivets in a variety of fatigue test specimens. The inspection task was to detect and plot crack growth from numbered fasteners in lettered rows. In January, 1998, the system was taken to Northwest Airlines Maintenance Base, in Atlanta, to inspect a DC-9, for multi-site cracks in three circumferential splices. The aircraft had 83,000 cycles. The inspection was conducted at 30 kHz from longeron 5 left to longeron 5 right. The system was calibrated using a 0,030 EDM first layer notch. The instrument gain was set to 19 mV from the notch. The reject level was set at 10 mV and the unflawed fasteners yielded a signal amplitude of 2 to 3 mV. Only one fastener location, out of about 2,500 tested, yielded a signal of 58 mV. The rivet was removed and visually evaluated. It appeared to be a slight gouge in the counter-sink zone. No fatigue cracks were detected. The same fastener locations were also inspected using the Boeing MAUS system at 60 kHz. No cracks were detected. Thus far, the rotating probe eddy current system has been found to be very user friendly and capable of detecting first layer cracks on the order of 0.030 inch long or longer.
Global Environmental Micro Sensors Test Operations in the Natural Environment
NASA Technical Reports Server (NTRS)
Adams, Mark L.; Buza, Matthew; Manobianco, John; Merceret, Francis J.
2007-01-01
ENSCO, Inc. is developing an innovative atmospheric observing system known as Global Environmental Micro Sensors (GEMS). The GEMS concept features an integrated system of miniaturized in situ, airborne probes measuring temperature, relative humidity, pressure, and vector wind velocity. In order for the probes to remain airborne for long periods of time, their design is based on a helium-filled super-pressure balloon. The GEMS probes are neutrally buoyant and carried passively by the wind at predetermined levels. Each probe contains onboard satellite communication, power generation, processing, and geolocation capabilities. ENSCO has partnered with the National Aeronautics and Space Administration's Kennedy Space Center (KSC) for a project called GEMS Test Operations in the Natural Environment (GEMSTONE) that will culminate with limited prototype flights of the system in spring 2007. By leveraging current advances in micro and nanotechnology, the probe mass, size, cost, and complexity can be reduced substantially so that large numbers of probes could be deployed routinely to support ground, launch, and landing operations at KSC and other locations. A full-scale system will improve the data density for the local initialization of high-resolution numerical weather prediction systems by at least an order of magnitude and provide a significantly expanded in situ data base to evaluate launch commit criteria and flight rules. When applied to launch or landing sites, this capability will reduce both weather hazards and weather-related scrubs, thus enhancing both safety and cost-avoidance for vehicles processed by the Shuttle, Launch Services Program, and Constellation Directorates. The GEMSTONE project will conclude with a field experiment in which 10 to 15 probes are released over KSC in east central Florida. The probes will be neutrally buoyant at different altitudes from 500 to 3000 meters and will report their position, speed, heading, temperature, humidity, and pressure via satellite. The GEMS data will be validated against reference observations provided by current weather instrumentation located at KSC. This paper will report on the results of the GEMSTONE project and discuss the challenges encountered in developing an airborne sensor system.
NASA Astrophysics Data System (ADS)
Newman, Richard; van der Ventel, Brandon; Hanekom, Crischelle
2017-07-01
Probing university students’ understanding of direct-current (DC) resistive circuits is still a field of active physics education research. We report here on a study we conducted of this understanding, where the cohort consisted of students in a large-enrollment first-year physics module. This is a non-calculus based physics module for students in the life sciences stream. The study involved 366 students enrolled in the physics (bio) 154 module at Stellenbosch University in 2015. Students’ understanding of DC resistive circuits was probed by means of a standardized test instrument. The instrument comprises 29 multiple choice questions that students have to answer in ~40 min. Students were required to first complete the standardized test at the start of semester (July 2015). For ease of reference we call this test the pre-test. Students answered the pre-test having no university-level formal exposure to DC circuits in theory or practice. The pre-test therefore served to probe students’ school level knowledge of DC circuits. As the semester progressed students were exposed to a practical (E1), lectures, a prescribed textbook, a tutorial and online videos focusing on DC circuits. The E1 practical required students to solve DC circuit problems by means of physically constructing circuits, algebraically using Kirchhoff's Rules and Ohm’s Law, and by means of simulating circuits using the app iCircuit running on iPads (iOS platform). Each E1 practical involved ~50 students in a three hour session. The practical was repeated three afternoons per week over an eight week period. Twenty three iPads were distributed among students on a practical afternoon in order for them to do the circuit simulations in groups (of 4-5 students). At the end of the practical students were again required to do the standardized test on circuits and complete a survey on their experience of the use of the iPad and iCircuit app. For ease of reference we refer to this second test as the post-test. The students’ average score on the post-test was found to be ~25% higher than their pre-test score. The results of the iPad use survey show that the majority of students felt that the iCircuit app enhanced their learning of DC circuits.
NASA Astrophysics Data System (ADS)
Mandache, C.; Khan, M.; Fahr, A.; Yanishevsky, M.
2011-03-01
Probability of detection (PoD) studies are broadly used to determine the reliability of specific nondestructive inspection procedures, as well as to provide data for damage tolerance life estimations and calculation of inspection intervals for critical components. They require inspections on a large set of samples, a fact that makes these statistical assessments time- and cost-consuming. Physics-based numerical simulations of nondestructive testing inspections could be used as a cost-effective alternative to empirical investigations. They realistically predict the inspection outputs as functions of the input characteristics related to the test piece, transducer and instrument settings, which are subsequently used to partially substitute and/or complement inspection data in PoD analysis. This work focuses on the numerical modelling aspects of eddy current testing for the bolt hole inspections of wing box structures typical of the Lockheed Martin C-130 Hercules and P-3 Orion aircraft, found in the air force inventory of many countries. Boundary element-based numerical modelling software was employed to predict the eddy current signal responses when varying inspection parameters related to probe characteristics, crack geometry and test piece properties. Two demonstrator exercises were used for eddy current signal prediction when lowering the driver probe frequency and changing the material's electrical conductivity, followed by subsequent discussions and examination of the implications on using simulated data in the PoD analysis. Despite some simplifying assumptions, the modelled eddy current signals were found to provide similar results to the actual inspections. It is concluded that physics-based numerical simulations have the potential to partially substitute or complement inspection data required for PoD studies, reducing the cost, time, effort and resources necessary for a full empirical PoD assessment.
Gurkov, Anton; Sadovoy, Anton; Shchapova, Ekaterina; Teh, Cathleen; Meglinski, Igor; Timofeyev, Maxim
2017-01-01
In vivo physiological measurement is a major challenge in modern science and technology, as is environment conservation at the global scale. Proper toxicological testing of widely produced mixtures of chemicals is a necessary step in the development of new products, allowing us to minimize the human impact on aquatic ecosystems. However, currently available bioassay-based techniques utilizing small aquatic organisms such as fish embryos for toxicity testing do not allow assessing in time the changes in physiological parameters in the same individual. In this study, we introduce microencapsulated fluorescent probes as a promising tool for in vivo monitoring of internal pH variation in zebrafish embryos. The pH alteration identified under stress conditions demonstrates the applicability of the microencapsulated fluorescent probes for the repeated analysis of the embryo's physiological state. The proposed approach has strong potential to simultaneously measure a range of physiological characteristics using a set of specific fluorescent probes and to finally bring toxicological bioassays and related research fields to a new level of effectiveness and sensitivity.
1998-03-31
plasma focus discharges. Part of the tests summarized here address methods and means for achieving controlled variations of the current sheath (CS) structure via electrode geometry modifications. CS parameters are monitored with multiple magnetic probes in the case of cylindrical - and open-funnel electrode
Plume characteristics of MPD thrusters: A preliminary examination
NASA Technical Reports Server (NTRS)
Myers, Roger M.
1989-01-01
A diagnostics facility for MPD thruster plume measurements was built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1x10(2) to 2x10(18)/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission also decays exponentially. Current distribution measurements indicate that a significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.
NeuroMEMS: Neural Probe Microtechnologies
HajjHassan, Mohamad; Chodavarapu, Vamsy; Musallam, Sam
2008-01-01
Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer's, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultra-long multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies. PMID:27873894
Steam generator tube inspection in Japan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukui, Shigetaka
1997-02-01
Steam generator tube inspection was first carried out in 1971 at Mihama Unit-1 that is first PWR plant in Japan, when the plant was brought into the first annual inspection. At that time, inspection was made on sampling basis, and only bobbin coil probe was used. After experiencing various kinds of tube degradations, inspection method was changed from sampling to all number of tubes, and various kinds of probes were used to get higher detectability of flaw. At present, it is required that all the tubes shall be inspected in their full length at each annual inspection using standard bobbinmore » coil probe, and some special probes for certain plants that have susceptibility of occurrence of flaw. Sleeve repaired portion is included in this inspection. As a result of analyses of eddy current testing data, all indications that have been evaluated to be 20% wall thickness or deeper shall be repaired by either plugging or sleeving, where flaw morphology is to be a wastage or wear. Other types of flaw such as IGA/SCC are not allowed to be left inservice when those indications are detected. These inspections are performed according to inspection procedures that are approved by regulatory authority. Actual inspections are witnessed by the Japan Power engineering and inspection corporation (JAPEIC)`s inspectors during data acquisition and analysis, and they issue inspection report to authority for review and approval. It is achieved high safety performance of steam generator through this method of inspections, however. some tube leakage problems were experienced in the past. To prevent recurrence of such events, government is conducting development and verification test program for new eddy current testing technology.« less
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2014-07-08
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-01-27
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-02-24
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
2004-07-01
The ability of a magnetically-filtered Faraday probe (MFFP) to obtain the ion current density profile of a Hall thruster is investigated. The MFFP is...MFFP, boxed Faraday probe (BFP), and nude Faraday probe are used to measure the ion current density profile of a 5 kW Hall thruster operated over the
Bringing Standardized Processes in Atom-Probe Tomography: I Establishing Standardized Terminology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Ian M; Danoix, F; Forbes, Richard
2011-01-01
Defining standardized methods requires careful consideration of the entire field and its applications. The International Field Emission Society (IFES) has elected a Standards Committee, whose task is to determine the needed steps to establish atom-probe tomography as an accepted metrology technique. Specific tasks include developing protocols or standards for: terminology and nomenclature; metrology and instrumentation, including specifications for reference materials; test methodologies; modeling and simulations; and science-based health, safety, and environmental practices. The Committee is currently working on defining terminology related to atom-probe tomography with the goal to include terms into a document published by the International Organization for Standardsmore » (ISO). A lot of terms also used in other disciplines have already been defined) and will be discussed for adoption in the context of atom-probe tomography.« less
Comparison of modern icing cloud instruments
NASA Technical Reports Server (NTRS)
Takeuchi, D. M.; Jahnsen, L. J.; Callander, S. M.; Humbert, M. C.
1983-01-01
Intercomparison tests with Particle Measuring Systems (PMS) were conducted. Cloud liquid water content (LWC) measurements were also taken with a Johnson and Williams (JW) hot-wire device and an icing rate device (Leigh IDS). Tests include varying cloud LWC (0.5 to 5 au gm), cloud median volume diameter (MVD) (15 to 26 microns), temperature (-29 to 20 C), and air speeds (50 to 285 mph). Comparisons were based upon evaluating probe estimates of cloud LWC and median volume diameter for given tunnel settings. Variations of plus or minus 10% and plus or minus 5% in LWC and MVD, respectively, were determined of spray clouds between test made at given tunnel settings (fixed LWC, MVD, and air speed) indicating cloud conditions were highly reproducible. Although LWC measurements from JW and Leigh devices were consistent with tunnel values, individual probe measurements either consistently over or underestimated tunnel values by factors ranging from about 0.2 to 2. Range amounted to a factor of 6 differences between LWC estimates of probes for given cloud conditions. For given cloud conditions, estimates of cloud MVD between probes were within plus or minus 3 microns and 93% of the test cases. Measurements overestimated tunnel values in the range between 10 to 20 microns. The need for improving currently used calibration procedures was indicated. Establishment of test facility (or facilities) such as an icing tunnel where instruments can be calibrated against known cloud standards would be a logical choice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young-Cheol; Kim, Yu-Sin; Lee, Hyo-Chang
2015-08-15
The electrical probe diagnostics are very hard to be applied to atmospheric plasmas due to severe perturbation by the electrical probes. To overcome this, the probe for measuring electron temperature and ion current density is indirectly contacted with an atmospheric jet source. The plasma parameters are obtained by using floating harmonic analysis. The probe is mounted on the quartz tube that surrounds plasma. When a sinusoidal voltage is applied to a probe contacting on a quartz tube, the electrons near the sheath at dielectric tube are collected and the probe current has harmonic components due to probe sheath nonlinearity. Frommore » the relation of the harmonic currents and amplitude of the sheath voltage, the electron temperature near the wall can be obtained with collisional sheath model. The electron temperatures and ion current densities measured at the discharge region are in the ranges of 2.7–3.4 eV and 1.7–5.2 mA/cm{sup 2} at various flow rates and input powers.« less
Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.
2007-01-01
Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.
Microencapsulation of Self-healing Concrete Properties
2012-08-01
1t does not display a currently valid OMB control number PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY) 12...and even by forms of organic matter (Ming Qiu Zhang et al 2011). All of these methods are currently undergoing testing and analysis in order to...dimensions at resolution near 0.1 nm. Using a tunneling current applied to a probe tip that is rastered across the surface, the electrons from the
Design and Application of Hybrid Magnetic Field-Eddy Current Probe
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Wallace, Terryl; Newman, Andy; Leser, Paul; Simpson, John
2013-01-01
The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.
Rapid Bacterial Testing for Spacecraft Water
NASA Technical Reports Server (NTRS)
Lisle, John T.; Pyle, Barry H.; McFeters, Gordon A.
1996-01-01
Evaluations of the fluorogenic stains and probes will continue. E. coli 0157:H7 will be used as the reference strain for optimizing protocols. We anticipate the continued use of the fluorescent antibodies (TRITC and FITC labeled) in conjunction with CTC, Rhl23, DiBAC4(3), DAPI and acridine orange. Chemunex, the manufacturer of the ChemScan analyzer system, also makes a fluorogenic probe, Chemchrome B, which will be incorporated into the suite of probes to evaluate once their system is on site. Regardless of the combination of stains and probes all will be evaluated on membrane filters. Development of a FISH protocol that will be applicable to our conditions will be continued. Complimentary 16s rRNA probes to Ps. aeruginosa and currently in our laboratory will be evaluated first. Once this protocol has been adequately optimized other probes will be ordered for u a select number of other species. Currently, protocols to evaluate the effects of disinfection and the resulting lethality, injury on stain and/or probe specificity and reliability are being developed. E. coli 0157:H7 is the reference strain and chlorine the disinfectant the reference protocol is being developed around. Upon completion of this work, the resulting protocol will be extended to other species and disinfectants (e.g., iodine). Similar disinfectant experiments will then be conducted on the same species after starvation to evaluate the effects of starvation on disinfection resistance and the applicability of the stains and probes. Development of the immunomagnetic separation system will continue. Combined with the rapid methods described above, with enumeration by the ChemScan, we anticipate that this will provide a highly sensitive technique for the detection of specific, active bacteria.
Apparatus for measuring high frequency currents
NASA Technical Reports Server (NTRS)
Hagmann, Mark J. (Inventor); Sutton, John F. (Inventor)
2003-01-01
An apparatus for measuring high frequency currents includes a non-ferrous core current probe that is coupled to a wide-band transimpedance amplifier. The current probe has a secondary winding with a winding resistance that is substantially smaller than the reactance of the winding. The sensitivity of the current probe is substantially flat over a wide band of frequencies. The apparatus is particularly useful for measuring exposure of humans to radio frequency currents.
Recent Advances in Simulation of Eddy Current Testing of Tubes and Experimental Validations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reboud, C.; Premel, D.; Lesselier, D.
2007-03-21
Eddy current testing (ECT) is widely used in iron and steel industry for the inspection of tubes during manufacturing. A collaboration between CEA and the Vallourec Research Center led to the development of new numerical functionalities dedicated to the simulation of ECT of non-magnetic tubes by external probes. The achievement of experimental validations led us to the integration of these models into the CIVA platform. Modeling approach and validation results are discussed here. A new numerical scheme is also proposed in order to improve the accuracy of the model.
Recent Advances in Simulation of Eddy Current Testing of Tubes and Experimental Validations
NASA Astrophysics Data System (ADS)
Reboud, C.; Prémel, D.; Lesselier, D.; Bisiaux, B.
2007-03-01
Eddy current testing (ECT) is widely used in iron and steel industry for the inspection of tubes during manufacturing. A collaboration between CEA and the Vallourec Research Center led to the development of new numerical functionalities dedicated to the simulation of ECT of non-magnetic tubes by external probes. The achievement of experimental validations led us to the integration of these models into the CIVA platform. Modeling approach and validation results are discussed here. A new numerical scheme is also proposed in order to improve the accuracy of the model.
NASA Astrophysics Data System (ADS)
Burrage, Clare; Sakstein, Jeremy
2018-03-01
Theories of modified gravity, where light scalars with non-trivial self-interactions and non-minimal couplings to matter—chameleon and symmetron theories—dynamically suppress deviations from general relativity in the solar system. On other scales, the environmental nature of the screening means that such scalars may be relevant. The highly-nonlinear nature of screening mechanisms means that they evade classical fifth-force searches, and there has been an intense effort towards designing new and novel tests to probe them, both in the laboratory and using astrophysical objects, and by reinterpreting existing datasets. The results of these searches are often presented using different parametrizations, which can make it difficult to compare constraints coming from different probes. The purpose of this review is to summarize the present state-of-the-art searches for screened scalars coupled to matter, and to translate the current bounds into a single parametrization to survey the state of the models. Presently, commonly studied chameleon models are well-constrained but less commonly studied models have large regions of parameter space that are still viable. Symmetron models are constrained well by astrophysical and laboratory tests, but there is a desert separating the two scales where the model is unconstrained. The coupling of chameleons to photons is tightly constrained but the symmetron coupling has yet to be explored. We also summarize the current bounds on f( R) models that exhibit the chameleon mechanism (Hu and Sawicki models). The simplest of these are well constrained by astrophysical probes, but there are currently few reported bounds for theories with higher powers of R. The review ends by discussing the future prospects for constraining screened modified gravity models further using upcoming and planned experiments.
Doyle, S J; Salvador, P R; Xu, K G
2017-11-01
The paper examines the effect of exposure time of Langmuir probes in an atmospheric premixed methane-air flame. The effects of probe size and material composition on current measurements were investigated, with molybdenum and tungsten probe tips ranging in diameter from 0.0508 to 0.1651 mm. Repeated prolonged exposures to the flame, with five runs of 60 s, resulted in gradual probe degradations (-6% to -62% area loss) which affected the measurements. Due to long flame exposures, two ion saturation currents were observed, resulting in significantly different ion densities ranging from 1.16 × 10 16 to 2.71 × 10 19 m -3 . The difference between the saturation currents is caused by thermionic emissions from the probe tip. As thermionic emission is temperature dependent, the flame temperature could thus be estimated from the change in current. The flame temperatures calculated from the difference in saturation currents (1734-1887 K) were compared to those from a conventional thermocouple (1580-1908 K). Temperature measurements obtained from tungsten probes placed in rich flames yielded the highest percent error (9.66%-18.70%) due to smaller emission current densities at lower temperatures. The molybdenum probe yielded an accurate temperature value with only 1.29% error. Molybdenum also demonstrated very low probe degradation in comparison to the tungsten probe tips (area reductions of 6% vs. 58%, respectively). The results also show that very little exposure time (<5 s) is needed to obtain a valid ion density measurement and that prolonged flame exposures can yield the flame temperature but also risks damage to the Langmuir probe tip.
Probe and Sensors Development for Level Measurement of Fats, Oils and Grease in Grease Boxes
Faria, José; Sousa, André; Reis, Arsénio; Filipe, Vitor; Barroso, João
2016-01-01
The wide spread of food outlets has become an environmental and sanitation infrastructure problem, due to Fats, Oils and Grease (FOG). A grease box is used at the industrials facilities to collect the FOG, in a specific time window, while its quality is good for recycling (e.g., biodiesel) and it is economically valuable. After this period, it will be disposed at a cost. For the proper management of the grease boxes, it is necessary to know the quantity of FOG inside the boxes, which is a major problem, as the boxes are sealed and permanently filled with water. The lack of homogeneity of the FOG renders it not detectable by current probes for level detection in liquids. In this article, the design, development and testing of a set of probes for FOG level measurement, based on the principles used in sensors for the detection of liquids inside containers, is described. The most suitable probe, based on the capacitance principle, together with the necessary hardware and software modules for data acquisition and transmission, was developed and tested. After the development phase, the probe was integrated on a metropolitan system for FOG collection and grease box management in partnership with a grease box management company. PMID:27649204
Probe and Sensors Development for Level Measurement of Fats, Oils and Grease in Grease Boxes.
Faria, José; Sousa, André; Reis, Arsénio; Filipe, Vitor; Barroso, João
2016-09-16
The wide spread of food outlets has become an environmental and sanitation infrastructure problem, due to Fats, Oils and Grease (FOG). A grease box is used at the industrials facilities to collect the FOG, in a specific time window, while its quality is good for recycling (e.g., biodiesel) and it is economically valuable. After this period, it will be disposed at a cost. For the proper management of the grease boxes, it is necessary to know the quantity of FOG inside the boxes, which is a major problem, as the boxes are sealed and permanently filled with water. The lack of homogeneity of the FOG renders it not detectable by current probes for level detection in liquids. In this article, the design, development and testing of a set of probes for FOG level measurement, based on the principles used in sensors for the detection of liquids inside containers, is described. The most suitable probe, based on the capacitance principle, together with the necessary hardware and software modules for data acquisition and transmission, was developed and tested. After the development phase, the probe was integrated on a metropolitan system for FOG collection and grease box management in partnership with a grease box management company.
2010-01-01
Background The hepatitis C virus (HCV) genome is extremely heterogeneous. Several HCV infections can not be detected using currently available commercial assays, probably because of mismatches between the template and primers/probes. By aligning the HCV sequences, we developed a duplex real-time reverse transcriptase-polymerase chain reaction (RT-PCR) assay using 2 sets of primers/probes and a specific armored RNA as internal control. The 2 detection probes were labelled with the same fluorophore, namely, 6-carboxyfluorescein (FAM), at the 5' end; these probes could mutually combine, improving the power of the test. Results The limit of detection of the duplex primer/probe assay was 38.99 IU/ml. The sensitivity of the assay improved significantly, while the specificity was not affected. All HCV genotypes in the HCV RNA Genotype Panel for Nucleic Acid Amplification Techniques could be detected. In the testing of 109 serum samples, the performance of the duplex real-time RT-PCR assay was identical to that of the COBAS AmpliPrep (CAP)/COBAS TaqMan (CTM) assay and superior to 2 commercial HCV assay kits. Conclusions The duplex real-time RT-PCR assay is an efficient and effective viral assay. It is comparable with the CAP/CTM assay with regard to the power of the test and is appropriate for blood-donor screening and laboratory diagnosis of HCV infection. PMID:20529244
Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Ratcliffe, Alicia C.
2018-01-01
The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.
Eddy current probe with foil sensor mounted on flexible probe tip and method of use
Viertl, John R. M.; Lee, Martin K.
2001-01-01
A pair of copper coils are embedded in the foil strip. A first coil of the pair generates an electromagnetic field that induces eddy currents on the surface, and the second coil carries a current influenced by the eddy currents on the surface. The currents in the second coil are analyzed to obtain information on the surface eddy currents. An eddy current probe has a metal housing having a tip that is covered by a flexible conductive foil strip. The foil strip is mounted on a deformable nose at the probe tip so that the strip and coils will conform to the surface to which they are applied.
EVALUATION OF A DNA PROBE TEST KIT FOR DETECTION OF SALMONELLAE IN BIOSOLIDS
Aims: Current United States regulations (40 CFR 503) for "Class A" biosolids requires use of multiple-tube fermentation techniques for fecal coliform or multiple tube enrichment techniques for Salmonella spp. followed by isolation and biochemical and serological confirmation. T...
Individually addressable vertically aligned carbon nanofiber-based electrochemical probes
NASA Astrophysics Data System (ADS)
Guillorn, M. A.; McKnight, T. E.; Melechko, A.; Merkulov, V. I.; Britt, P. F.; Austin, D. W.; Lowndes, D. H.; Simpson, M. L.
2002-03-01
In this paper we present the fabrication and initial testing results of high aspect ratio vertically aligned carbon nanofiber (VACNF)-based electrochemical probes. Electron beam lithography was used to define the catalytic growth sites of the VACNFs. Following catalyst deposition, VACNF were grown using a plasma enhanced chemical vapor deposition process. Photolithography was performed to realize interconnect structures. These probes were passivated with a thin layer of SiO2, which was then removed from the tips of the VACNF, rendering them electrochemically active. We have investigated the functionality of completed devices using cyclic voltammetry (CV) of ruthenium hexammine trichloride, a highly reversible, outer sphere redox system. The faradaic current obtained during CV potential sweeps shows clear oxidation and reduction peaks at magnitudes that correspond well with the geometry of these nanoscale electrochemical probes. Due to the size and the site-specific directed synthesis of the VACNFs, these probes are ideally suited for characterizing electrochemical phenomena with an unprecedented degree of spatial resolution.
Force modulation and electrochemical gating of conductance in a cytochrome
NASA Astrophysics Data System (ADS)
Davis, Jason J.; Peters, Ben; Xi, Wang
2008-09-01
Scanning probe methods have been used to measure the effect of electrochemical potential and applied force on the tunnelling conductance of the redox metalloprotein yeast iso-1-cytochrome c (YCC) at a molecular level. The interaction of a proximal probe with any sample under test will, at this scale, be inherently perturbative. This is demonstrated with conductive probe atomic force microscopy (CP-AFM) current-voltage spectroscopy in which YCC, chemically adsorbed onto pristine Au(111) via its surface cysteine residue, is observed to become increasingly compressed as applied load is increased, with concomitant decrease in junction resistance. Electrical contact at minimal perturbation, where probe-molecule coupling is comparable to that in scanning tunnelling microscopy, brings with it the observation of negative differential resistance, assigned to redox-assisted probe-substrate tunnelling. The role of the redox centre in conductance is also resolved in electrochemical scanning tunnelling microscopy assays where molecular conductance is electrochemically gateable through more than an order of magnitude.
The design and application of fluorophore–gold nanoparticle activatable probes
Swierczewska, Magdalena; Lee, Seulki; Chen, Xiaoyuan
2013-01-01
Fluorescence-based assays and detection techniques are among the most highly sensitive and popular biological tests for researchers. To match the needs of research and the clinic, detection limits and specificities need to improve, however. One mechanism is to decrease non-specific background signals, which is most efficiently done by increasing fluorescence quenching abilities. Reports in the literature of theoretical and experimental work have shown that metallic gold surfaces and nanoparticles are ultra-efficient fluorescence quenchers. Based on these findings, subsequent reports have described gold nanoparticle fluorescence-based activatable probes that were designed to increase fluorescence intensity based on a range of stimuli. In this way, these probes can detect and signify assorted biomarkers and changes in environmental conditions. In this review, we explore the various factors and theoretical models that affect gold nanoparticle fluorescence quenching, explore current uses of activatable probes, and propose an engineering approach for future development of fluorescence based gold nanoparticle activatable probes. PMID:21380462
2009-09-01
elevated background pressure, compared nude Faraday probe designs, and evaluated design modifications to minimize uncertainty due to charge exchange...evaluated Faraday probe design and facility background pressure on collected ion current. A comparison of two nude Faraday probe designs concluded...140.5 Plasma potential in the region surrounding a nude Faraday probe has been measured to study the possibility of probe bias voltage acting as a
Implementation and Initial Validation of a 100-Kilowatt Class Nested-Channel Hall Thruster
NASA Technical Reports Server (NTRS)
Hall, Scott J.; Florenz, Roland E.; Gallimore, Alec D.; Kamhawi, Hani; Brown, Daniel L.; Polk, James E.; Goebel, Dan; Hofer, Richard R.
2014-01-01
The X3 is a 100-kilowatt class nested-channel Hall thruster developed by the Plasmadynamics and Electric Propulsion Laboratory at the University of Michigan in collaboration with the Air Force Research Laboratory and NASA. The cathode, magnetic circuit, boron nitride channel rings, and anodes all required specific design considerations during thruster development, and thermal modeling was used to properly account for thermal growth in material selection and component design. A number of facility upgrades were required at the University of Michigan to facilitate operation of the X3. These upgrades included a re-worked propellant feed system, a completely redesigned power and telemetry break-out box, and numerous updates to thruster handling equipment. The X3 was tested on xenon propellant at two current densities, 37% and 73% of the nominal design value. It was operated to a maximum steady-state discharge power of 60.8 kilowatts. The tests presented here served as an initial validation of thruster operation. Thruster behavior was monitored with telemetry, photography and high-speed current probes. The photography showed a uniform plume throughout testing. At constant current density, reductions in mass flow rate of 18% and 26% were observed in the three-channel operating configuration as compared to the superposition of each channel running individually. The high-speed current probes showed that the thruster was stable at all operating points and that the channels influence each other when more than one is operating simultaneously. Additionally, the ratio of peak-to-peak AC-coupled discharge current oscillations to mean discharge current did not exceed 51% for any operating points reported here, and did not exceed 17% at the higher current density.
The R&D progress of 4 MW EAST-NBI high current ion source.
Xie, Yahong; Hu, Chundong; Liu, Sheng; Xu, Yongjian; Liang, Lizhen; Xie, Yuanlai; Sheng, Peng; Jiang, Caichao; Liu, Zhimin
2014-02-01
A high current ion source, which consists of the multi-cusp bucket plasma generator and tetrode accelerator with multi-slot apertures, is developed and tested for the Experimental Advanced Superconducting Tokamak neutral beam injector. Three ion sources are tested on the test bed with arc power of 80 kW, beam voltage of 80 keV, and beam power of 4 MW. The arc regulation technology with Langmuir probes is employed for the long pulse operation of ion source, and the long pulse beam of 50 keV @ 15.5 A @ 100 s and 80 keV @ 52A @ 1s are extracted, respectively.
Theory of a cylindrical probe in a collisionless magnetoplasma
NASA Technical Reports Server (NTRS)
Laframboise, J. G.; Rubinstein, J.
1976-01-01
A theory is presented for a cylindrical electrostatic probe in a collisionless plasma in the case where the probe axis is inclined at an angle to a uniform magnetic field. The theory is applicable to electron collection, and under more restrictive conditions, to ion collection. For a probe at space potential, the theory is exact in the limit where probe radius is much less than Debye length. At attracting probe potentials, the theory yields an upper bound and an adiabatic limit for current collection. At repelling probe potentials, it provides a lower bound. The theory is valid if the ratios of probe radius to Debye length and probe radius to mean gyroradius are not simultaneously large enough to produce extrema in the probe sheath potential. The numerical current calculations are based on the approximation that particle orbits are helices near the probe, together with the use of kinetic theory to relate velocity distributions near the probe to those far from it. Probe characteristics are presented for inclination angles from 0 to 90 deg and for probe-radius mean-gyroradius ratios from 0.1 to infinity. For an angle of 0 deg, the end-effect current is calculated separately.
A milliKelvin scanning Hall probe microscope for high resolution magnetic imaging
NASA Astrophysics Data System (ADS)
Khotkevych, V. V.; Bending, S. J.
2009-02-01
The design and performance of a novel scanning Hall probe microscope for milliKelvin magnetic imaging with submicron lateral resolution is presented. The microscope head is housed in the vacuum chamber of a commercial 3He-refrigerator and operates between room temperature and 300 mK in magnetic fields up to 10 T. Mapping of the local magnetic induction at the sample surface is performed by a micro-fabricated 2DEG Hall probe equipped with an integrated STM tip. The latter provides a reliable mechanism of surface tracking by sensing and controlling the tunnel currents. We discuss the results of tests of the system and illustrate its potential with images of suitable reference samples captured in different modes of operation.
Dark energy two decades after: observables, probes, consistency tests.
Huterer, Dragan; Shafer, Daniel L
2018-01-01
The discovery of the accelerating universe in the late 1990s was a watershed moment in modern cosmology, as it indicated the presence of a fundamentally new, dominant contribution to the energy budget of the universe. Evidence for dark energy, the new component that causes the acceleration, has since become extremely strong, owing to an impressive variety of increasingly precise measurements of the expansion history and the growth of structure in the universe. Still, one of the central challenges of modern cosmology is to shed light on the physical mechanism behind the accelerating universe. In this review, we briefly summarize the developments that led to the discovery of dark energy. Next, we discuss the parametric descriptions of dark energy and the cosmological tests that allow us to better understand its nature. We then review the cosmological probes of dark energy. For each probe, we briefly discuss the physics behind it and its prospects for measuring dark energy properties. We end with a summary of the current status of dark energy research.
Design study of an entry probe spectro-reflectometer
NASA Technical Reports Server (NTRS)
Sill, G. T.; Fink, U.
1986-01-01
A wind tunnel was built to simulate the rapid movement of an entry probe through the Jupiter atmosphere. Wind speeds range from 1 to 50 meters per second in a closed system. Wind velocity and temperature probes as well as a cryogenically cooled cold finger can be placed in the 6 inch diameter viewing section. The initial testing of the wind tunnel involved running sectional profiles through the observation port of air currents of 0.1 to 3.0 atmosphere. The velocity profile was very uniform throughout the cross section of the experimental port, with the exception of the wall effects. The deposition of cooled volatiles using the wind tunnel was not performed. However, measurements of the deposition of H2O ice on a cryogenically cooled thickness modulator were made under ambient conditions, namely room temperature and pressure. In the Frost Depositon Test Facility, ice deposition was measured at thicknesses of about a half millimeter and frost was produced whose thickness reflectivity could easily be measured by reflectance spectroscopy.
Measured current drainage through holes in various dielectrics up to 2 kilovolts in a dilute plasma
NASA Technical Reports Server (NTRS)
Grier, N. T.; Mckinzie, D. J., Jr.
1972-01-01
The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.
Eddy Current Assessment of Engineered Components Containing Nanofibers
NASA Astrophysics Data System (ADS)
Ko, Ray T.; Hoppe, Wally; Pierce, Jenny
2009-03-01
The eddy current approach has been used to assess engineered components containing nanofibers. Five specimens with different programmed defects were fabricated. A 4-point collinear probe was used to verify the electrical resistivity of each specimen. The liftoff component of the eddy current signal was used to test two extreme cases with different nano contents. Additional eddy current measurements were also used in detecting a missing nano layer simulating a manufacturing process error. The results of this assessment suggest that eddy current liftoff measurement can be a useful tool in evaluating the electrical properties of materials containing nanofibers.
Sharp-Tip Silver Nanowires Mounted on Cantilevers for High-Aspect-Ratio High-Resolution Imaging.
Ma, Xuezhi; Zhu, Yangzhi; Kim, Sanggon; Liu, Qiushi; Byrley, Peter; Wei, Yang; Zhang, Jin; Jiang, Kaili; Fan, Shoushan; Yan, Ruoxue; Liu, Ming
2016-11-09
Despite many efforts to fabricate high-aspect-ratio atomic force microscopy (HAR-AFM) probes for high-fidelity, high-resolution topographical imaging of three-dimensional (3D) nanostructured surfaces, current HAR probes still suffer from unsatisfactory performance, low wear-resistivity, and extravagant prices. The primary objective of this work is to demonstrate a novel design of a high-resolution (HR) HAR AFM probe, which is fabricated through a reliable, cost-efficient benchtop process to precisely implant a single ultrasharp metallic nanowire on a standard AFM cantilever probe. The force-displacement curve indicated that the HAR-HR probe is robust against buckling and bending up to 150 nN. The probes were tested on polymer trenches, showing a much better image fidelity when compared with standard silicon tips. The lateral resolution, when scanning a rough metal thin film and single-walled carbon nanotubes (SW-CNTs), was found to be better than 8 nm. Finally, stable imaging quality in tapping mode was demonstrated for at least 15 continuous scans indicating high resistance to wear. These results demonstrate a reliable benchtop fabrication technique toward metallic HAR-HR AFM probes with performance parallel or exceeding that of commercial HAR probes, yet at a fraction of their cost.
Methods and instruments for materials testing
NASA Technical Reports Server (NTRS)
Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)
2011-01-01
Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.
Saka, Ernur; Harrison, Benjamin J; West, Kirk; Petruska, Jeffrey C; Rouchka, Eric C
2017-12-06
Since the introduction of microarrays in 1995, researchers world-wide have used both commercial and custom-designed microarrays for understanding differential expression of transcribed genes. Public databases such as ArrayExpress and the Gene Expression Omnibus (GEO) have made millions of samples readily available. One main drawback to microarray data analysis involves the selection of probes to represent a specific transcript of interest, particularly in light of the fact that transcript-specific knowledge (notably alternative splicing) is dynamic in nature. We therefore developed a framework for reannotating and reassigning probe groups for Affymetrix® GeneChip® technology based on functional regions of interest. This framework addresses three issues of Affymetrix® GeneChip® data analyses: removing nonspecific probes, updating probe target mapping based on the latest genome knowledge and grouping probes into gene, transcript and region-based (UTR, individual exon, CDS) probe sets. Updated gene and transcript probe sets provide more specific analysis results based on current genomic and transcriptomic knowledge. The framework selects unique probes, aligns them to gene annotations and generates a custom Chip Description File (CDF). The analysis reveals only 87% of the Affymetrix® GeneChip® HG-U133 Plus 2 probes uniquely align to the current hg38 human assembly without mismatches. We also tested new mappings on the publicly available data series using rat and human data from GSE48611 and GSE72551 obtained from GEO, and illustrate that functional grouping allows for the subtle detection of regions of interest likely to have phenotypical consequences. Through reanalysis of the publicly available data series GSE48611 and GSE72551, we profiled the contribution of UTR and CDS regions to the gene expression levels globally. The comparison between region and gene based results indicated that the detected expressed genes by gene-based and region-based CDFs show high consistency and regions based results allows us to detection of changes in transcript formation.
Eddy-Current Inspection of Ball Bearings
NASA Technical Reports Server (NTRS)
Bankston, B.
1985-01-01
Custom eddy-current probe locates surface anomalies. Low friction air cushion within cone allows ball to roll easily. Eddy current probe reliably detects surface and near-surface cracks, voids, and material anomalies in bearing balls or other spherical objects. Defects in ball surface detected by probe displayed on CRT and recorded on strip-chart recorder.
NASA Astrophysics Data System (ADS)
Brown, Alexander; Eviston, Connor
2017-02-01
Multiple FEM models of complex eddy current coil geometries were created and validated to calculate the change of impedance due to the presence of a notch. Capable realistic simulations of eddy current inspections are required for model assisted probability of detection (MAPOD) studies, inversion algorithms, experimental verification, and tailored probe design for NDE applications. An FEM solver was chosen to model complex real world situations including varying probe dimensions and orientations along with complex probe geometries. This will also enable creation of a probe model library database with variable parameters. Verification and validation was performed using other commercially available eddy current modeling software as well as experimentally collected benchmark data. Data analysis and comparison showed that the created models were able to correctly model the probe and conductor interactions and accurately calculate the change in impedance of several experimental scenarios with acceptable error. The promising results of the models enabled the start of an eddy current probe model library to give experimenters easy access to powerful parameter based eddy current models for alternate project applications.
Spin and precision electroweak physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marciano, W.J.
1994-12-01
A perspective on fundamental parameters and precision tests of the Standard Model is given. Weak neutral current reactions are discussed with emphasis on those processes involving (polarized) electrons. The role of electroweak radiative corrections in determining the top quark mass and probing for {open_quotes}new physics{close_quotes} is described.
ArrayInitiative - a tool that simplifies creating custom Affymetrix CDFs
2011-01-01
Background Probes on a microarray represent a frozen view of a genome and are quickly outdated when new sequencing studies extend our knowledge, resulting in significant measurement error when analyzing any microarray experiment. There are several bioinformatics approaches to improve probe assignments, but without in-house programming expertise, standardizing these custom array specifications as a usable file (e.g. as Affymetrix CDFs) is difficult, owing mostly to the complexity of the specification file format. However, without correctly standardized files there is a significant barrier for testing competing analysis approaches since this file is one of the required inputs for many commonly used algorithms. The need to test combinations of probe assignments and analysis algorithms led us to develop ArrayInitiative, a tool for creating and managing custom array specifications. Results ArrayInitiative is a standalone, cross-platform, rich client desktop application for creating correctly formatted, custom versions of manufacturer-provided (default) array specifications, requiring only minimal knowledge of the array specification rules and file formats. Users can import default array specifications, import probe sequences for a default array specification, design and import a custom array specification, export any array specification to multiple output formats, export the probe sequences for any array specification and browse high-level information about the microarray, such as version and number of probes. The initial release of ArrayInitiative supports the Affymetrix 3' IVT expression arrays we currently analyze, but as an open source application, we hope that others will contribute modules for other platforms. Conclusions ArrayInitiative allows researchers to create new array specifications, in a standard format, based upon their own requirements. This makes it easier to test competing design and analysis strategies that depend on probe definitions. Since the custom array specifications are easily exported to the manufacturer's standard format, researchers can analyze these customized microarray experiments using established software tools, such as those available in Bioconductor. PMID:21548938
Development and Application of Wide Bandwidth Magneto-Resistive Sensor Based Eddy Current Probe
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.; Simpson, John
2010-01-01
The integration of magneto-resistive sensors into eddy current probes can significantly expand the capabilities of conventional eddy current nondestructive evaluation techniques. The room temperature solid-state sensors have typical bandwidths in the megahertz range and resolutions of tens of microgauss. The low frequency sensitivity of magneto-resistive sensors has been capitalized upon in previous research to fabricate very low frequency eddy current sensors for deep flaw detection in multilayer conductors. In this work a modified probe design is presented to expand the capabilities of the device. The new probe design incorporates a dual induction source enabling operation from low frequency deep flaw detection to high frequency high resolution near surface material characterization. Applications of the probe for the detection of localized near surface conductivity anomalies are presented. Finite element modeling of the probe is shown to be in good agreement with experimental measurements.
Correcting magnetic probe perturbations on current density measurements of current carrying plasmas.
Knoblauch, P; Raspa, V; Di Lorenzo, F; Lazarte, A; Clausse, A; Moreno, C
2010-09-01
A method to infer the current density distribution in the current sheath of a plasma focus discharge from a magnetic probe is formulated and then applied to experimental data obtained in a 1.1 kJ device. Distortions on the magnetic probe signal caused by current redistribution and by a time-dependent total discharge current are considered simultaneously, leading to an integral equation for the current density. Two distinct, easy to implement, numerical procedures are given to solve such equation. Experimental results show the coexistence of at least two maxima in the current density structure of a nitrogen sheath.
Noncontact Measurement Of Sizes And Eccentricities Of Holes
NASA Technical Reports Server (NTRS)
Chern, Engmin J.
1993-01-01
Semiautomatic eddy-current-probe apparatus makes noncontact measurements of nominally round holes in electrically conductive specimens and processes measurement data into diameters and eccentricities of holes. Includes x-y translation platform, which holds specimen and moves it horizontally. Probe mounted on probe scanner, positioning probe along vertical (z) direction and rotates probe about vertical axis at preset low speed. Eddy-current sensing coil mounted in side of probe near tip. As probe rotates, impedance analyzer measures electrical impedance (Z) of coil as function of instantaneous rotation angle. Translation and rotation mechanisms and impedance analyzer controlled by computer, which also processes impedance-measurement data.
Nucleic acid probes in diagnostic medicine
NASA Technical Reports Server (NTRS)
Oberry, Phillip A.
1991-01-01
The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.
YOUNG, Jared W; POWELL, Susan; RISBROUGH, Victoria; MARSTON, Hugh M; GEYER, Mark A
2009-01-01
Cognitive deficits in schizophrenia are among the core symptoms of the disease, correlate with functional outcome, and are not well treated with current antipsychotic therapies. In order to bring together academic, industrial, and governmental bodies to address this great ‘unmet therapeutic need’, the NIMH sponsored the Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) initiative. Through careful factor analysis and consensus of expert opinion, MATRICS identified seven domains of cognition that are deficient in schizophrenia (attention/vigilance, working memory, reasoning and problem solving, processing speed, visual learning and memory, verbal learning and memory, and social cognition) and recommended a specific neuropsychological test battery to probe these domains. In order to move the field forward and outline an approach for translational research, there is a need for a “preclinical MATRICS” to develop a rodent test battery that is appropriate for drug development. In this review, we outline such an approach and review current rodent tasks that target these seven domains of cognition. The rodent tasks are discussed in terms of their validity for probing each cognitive domain as well as a brief overview of the pharmacology and manipulations relevant to schizophrenia for each task. PMID:19269307
Plasma Propulsion Testing Capabilities at Arnold Engineering Development Center
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Dawbarn, Albert; Moeller, Trevor
2007-01-01
This paper describes the results of a series of experiments aimed at quantifying the plasma propulsion testing capabilities of a 12-ft diameter vacuum facility (12V) at USAF-Arnold Engineering Development Center (AEDC). Vacuum is maintained in the 12V facility by cryogenic panels lining the interior of the chamber. The pumping capability of these panels was shown to be great enough to support plasma thrusters operating at input electrical power >20 kW. In addition, a series of plasma diagnostics inside the chamber allowed for measurement of plasma parameters at different spatial locations, providing information regarding the chamber's effect on the global plasma thruster flowfield. The plasma source used in this experiment was Hall thruster manufactured by Busek Co. The thruster was operated at up to 20 kW steady-state power in both a lower current and higher current mode. The vacuum level in the chamber never rose above 9 x 10(exp -6) torr during the course of testing. Langmuir probes, ion flux probes, and Faraday cups were used to quantify the plasma parameters in the chamber. We present the results of these measurements and estimates of pumping speed based on the background pressure level and thruster propellant mass flow rate.
Grot, Stephen Andreas; Meltser, Mark Alexander; Gutowski, Stanley; Neutzler, Jay Kevin; Borup, Rodney Lynn; Weisbrod, Kirk
1999-12-14
The CO concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and/or voltage behavior patterns from a PEM-probe communicating with the reformate feed stream. Pattern recognition software may be used to compare the current and voltage patterns from the PEM-probe to current and voltage telltale outputs determined from a reference cell similar to the PEM-probe and operated under controlled conditions over a wide range of CO concentrations in the H.sub.2 fuel stream. A CO sensor includes the PEM-probe, an electrical discharge circuit for discharging the PEM-probe to monitor the CO concentration, and an electrical purging circuit to intermittently raise the anode potential of the PEM-probe's anode to at least about 0.8 V (RHE) to electrochemically oxidize any CO adsorbed on the probe's anode catalyst.
Method of monitoring CO concentrations in hydrogen feed to a PEM fuel cell
Grot, Stephen Andreas; Meltser, Mark Alexander; Gutowski, Stanley; Neutzler, Jay Kevin; Borup, Rodney Lynn; Weisbrod, Kirk
2000-01-01
The CO concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and/or voltage behavior patterns from a PEM-probe communicating with the reformate feed stream. Pattern recognition software may be used to compare the current and voltage patterns from the PEM-probe to current and voltage telltale outputs determined from a reference cell similar to the PEM-probe and operated under controlled conditions over a wide range of CO concentrations in the H.sub.2 fuel stream. The PEM-probe is intermittently purged of any CO build-up on the anode catalyst (e.g., by (1) flushing the anode with air, (2) short circuiting the PEM-probe, or (3) reverse biasing the PEM-probe) to keep the PEM-probe at peak performance levels.
GMR-based eddy current probe for weld seam inspection and its non-scanning detection study
NASA Astrophysics Data System (ADS)
Gao, Peng; Wang, Chao; Li, Yang; Wang, Libin; Cong, Zheng; Zhi, Ya
2017-04-01
Eddy current testing is one of the most important non-destructive testing methods for welding defects detection. This paper presents the use of a probe consisting of 4 giant magneto-resistive (GMR) sensors to detect weld defects. Information from four measuring points above and on both sides of the weld seam is collected at the same time. By setting the GMR sensors' sensing axes perpendicular to the direction of the excitation magnetic field, the information collected mainly reflects the change in the eddy current which is caused by defects. Digital demodulation technology is applied to extract the real part and imaginary part of the GMR sensors' output signals. The variables containing directional information of the magnetic field are introduced. Based on the data from the four GMR (4-GMR) sensors' output signals, four values, Ran, Mean, Var and k are selected as the feature quantities for defect recognition. Experiments are carried out on weld seams with and without defects, and the detection outputs are given in this paper. The 4-GMR probe is also employed to investigate non-scanning weld defect detection and the four feature quantities (Ran, Mean, Var and k) are studied to evaluate weld quality. The non-scanning weld defect detection is presented. A support vector machine is used to classify and discriminate welds with and without defects. Experiments carried out show that through the method in this paper, the recognition rate is 92% for welds without defects and 90% for welds with defects, with an overall recognition rate of 90.9%, indicating that this method could effectively detect weld defects.
Reyno, Tyler; Underhill, P. Ross; Krause, Thomas W.; Marsden, Catharine; Wowk, Diane
2017-01-01
Surface damage on honeycomb aircraft panels is often measured manually, and is therefore subject to variation based on inspection personnel. Eddy current testing (ECT) is sensitive to variations in probe-to-specimen spacing, or lift-off, and is thus promising for high-resolution profiling of surface damage on aluminum panels. Lower frequency testing also allows inspection through the face sheet, an advantage over optical 3D scanning methods. This paper presents results from the ECT inspection of surface damage on an approximately flat aluminum honeycomb aircraft panel, and compares the measurements to those taken using optical 3D scanning technology. An ECT C-Scan of the dented panel surface was obtained by attaching the probe to a robotic scanning apparatus. Data was taken simultaneously at four frequencies of 25, 100, 400 and 1600 kHz. A reference surface was then defined that approximated the original, undamaged panel surface, which also compensated for the effects of specimen tilt and thermal drift within the ECT instrument. Data was converted to lift-off using height calibration curves developed for each probe frequency. A damage region of 22,550 mm2 area with dents ranging in depth from 0.13–1.01 mm was analyzed. The method was accurate at 1600 kHz to within 0.05 mm (2σ) when compared with 231 measurements taken via optical 3D scanning. Testing at 25 kHz revealed a 3.2 mm cell size within the honeycomb core, which was confirmed via destructive evaluation. As a result, ECT demonstrates potential for implementation as a method for rapid in-field aircraft panel surface damage assessment. PMID:28906434
Reyno, Tyler; Underhill, P Ross; Krause, Thomas W; Marsden, Catharine; Wowk, Diane
2017-09-14
Surface damage on honeycomb aircraft panels is often measured manually, and is therefore subject to variation based on inspection personnel. Eddy current testing (ECT) is sensitive to variations in probe-to-specimen spacing, or lift-off, and is thus promising for high-resolution profiling of surface damage on aluminum panels. Lower frequency testing also allows inspection through the face sheet, an advantage over optical 3D scanning methods. This paper presents results from the ECT inspection of surface damage on an approximately flat aluminum honeycomb aircraft panel, and compares the measurements to those taken using optical 3D scanning technology. An ECT C-Scan of the dented panel surface was obtained by attaching the probe to a robotic scanning apparatus. Data was taken simultaneously at four frequencies of 25, 100, 400 and 1600 kHz. A reference surface was then defined that approximated the original, undamaged panel surface, which also compensated for the effects of specimen tilt and thermal drift within the ECT instrument. Data was converted to lift-off using height calibration curves developed for each probe frequency. A damage region of 22,550 mm² area with dents ranging in depth from 0.13-1.01 mm was analyzed. The method was accurate at 1600 kHz to within 0.05 mm (2σ) when compared with 231 measurements taken via optical 3D scanning. Testing at 25 kHz revealed a 3.2 mm cell size within the honeycomb core, which was confirmed via destructive evaluation. As a result, ECT demonstrates potential for implementation as a method for rapid in-field aircraft panel surface damage assessment.
Atmospheric Probe Model: Construction and Wind Tunnel Tests
NASA Technical Reports Server (NTRS)
Vogel, Jerald M.
1998-01-01
The material contained in this document represents a summary of the results of a low speed wind tunnel test program to determine the performance of an atmospheric probe at low speed. The probe configuration tested consists of a 2/3 scale model constructed from a combination of hard maple wood and aluminum stock. The model design includes approximately 130 surface static pressure taps. Additional hardware incorporated in the baseline model provides a mechanism for simulating external and internal trailing edge split flaps for probe flow control. Test matrix parameters include probe side slip angle, external/internal split flap deflection angle, and trip strip applications. Test output database includes surface pressure distributions on both inner and outer annular wings and probe center line velocity distributions from forward probe to aft probe locations.
Magnetic dipole discharges. II. Cathode and anode spot discharges and probe diagnostics
NASA Astrophysics Data System (ADS)
Stenzel, R. L.; Urrutia, J. M.; Ionita, C.; Schrittwieser, R.
2013-08-01
The high current regime of a magnetron-type discharge has been investigated. The discharge uses a permanent magnet as a cold cathode which emits secondary electrons while the chamber wall or a grounded electrode serves as the anode. As the discharge voltage is increased, the magnet develops cathode spots, which are short duration arcs that provide copious electrons to increase the discharge current dramatically. Short (1 μs), high current (200 A) and high voltage (750 V) discharge pulses are produced in a relaxation instability between the plasma and a charging capacitor. Spots are also observed on a negatively biased plane Langmuir probe. The probe current pulses are as large as those on the magnet, implying that the high discharge current does not depend on the cathode surface area but on the properties of the spots. The fast current pulses produce large inductive voltages, which can reverse the electrical polarity of the magnet and temporarily operate it as an anode. The discharge current may also oscillate at the frequency determined by the charging capacitor and the discharge circuit inductance. Each half cycle of high-current current pulses exhibits a fast (≃10 ns) current rise when a spot is formed. It induces high frequency (10-100 MHz) transients and ringing oscillations in probes and current circuits. Most probes behave like unmatched antennas for the electromagnetic pulses of spot discharges. Examples are shown to distinguish the source of oscillations and some rf characteristics of Langmuir probes.
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
49 CFR 572.74 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... by a test probe conforming to § 572.77(a) to 20 ±0.3 fps according to the test procedure in paragraph... longitudinal center line of the test probe so that it coincides with the designated impact point, and align the test probe so that at impact, the probe's longitudinal center line coincides (within 2 degrees) with...
NASA Astrophysics Data System (ADS)
Shih, T. I.; Lin, Y. C.; Duh, J. G.; Hsu, Tom
2006-10-01
Lead-free solder bumps have been widely used in current flip-chip technology (FCT) due to environmental issues. Solder joints after temperature cycling tests were employed to investigate the interfacial reaction between the Ti/Ni/Cu under-bump metallization and Sn-Ag-Cu solders. The interfacial morphology and quantitative analysis of the intermetallic compounds (IMCs) were obtained by electron probe microanalysis (EPMA) and field emission electron probe microanalysis (FE-EPMA). Various types of IMCs such as (Cu1-x,Agx)6Sn5, (Cu1-y,Agy)3Sn, and (Ag1-z,Cuz)3Sn were observed. In addition to conventional I-V measurements by a special sample preparation technique, a scanning electron microscope (SEM) internal probing system was introduced to evaluate the electrical characteristics in the IMCs after various test conditions. The electrical data would be correlated to microstructural evolution due to the interfacial reaction between the solder and under-bump metallurgy (UBM). This study demonstrated the successful employment of an internal nanoprobing approach, which would help further understanding of the electrical behavior within an IMC layer in the solder/UBM assembly.
NASA Astrophysics Data System (ADS)
O'Shea, Peter; Laberge, Michel; Mossman, Alex; Reynolds, Meritt
2017-10-01
Magnetic reconstructions on lab based plasma injectors at General Fusion relies heavily on edge magnetic (``Bdot'') probes. On plasma experiments built for field compression (PCS) tests, the number and locations of Bdot probes is limited by mechanical constraints. Additional information about the q profiles near the core in our Spector plasmas is obtained using passive MHD spectroscopy. The coaxial helicity injection (CHI) formation process naturally generates hollow current profiles and reversed shear early in each discharge. Central Ohmic heating naturally peaks the current profiles as our plasmas evolve in time, simultaneously reducing the core safety factor, q(0), and reverse shear. As the central, non-monotonic q-profile crosses rational flux surfaces, we observe transient magnetic reconnection events (MRE's) due to the double tearing mode. Modal analysis allows us to infer the q surfaces involved in each burst. The parametric dependence of the timing of MRE's allows us to estimate the continuous time evolution of the core q profile. Combining core MHD spectroscopy with edge magnetic probe measurements greatly enhances our certainty of the overall q profile.
Determination of plasma density from data on the ion current to cylindrical and planar probes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voloshin, D. G., E-mail: dvoloshin@mics.msu.su; Vasil’eva, A. N.; Kovalev, A. S.
2016-12-15
To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models weremore » used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.« less
Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement
NASA Technical Reports Server (NTRS)
Chern, E. James
1998-01-01
Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.
An integrated eddy current detection and imaging system on a silicon chip
NASA Technical Reports Server (NTRS)
Henderson, H. Thurman; Kartalia, K. P.; Dury, Joseph D.
1991-01-01
Eddy current probes have been used for many years for numerous sensing applications including crack detection in metals. However, these applications have traditionally used the eddy current effect in the form of a physically wound single or different probe pairs which of necessity must be made quite large compared to microelectronics dimensions. Also, the traditional wound probe can only take a point reading, although that point might include tens of individual cracks or crack arrays; thus, conventional eddy current probes are beset by two major problems: (1) no detailed information can be obtained about the crack or crack array; and (2) for applications such as quality assurance, a vast amount of time must be taken to scan a complete surface. Laboratory efforts have been made to fabricate linear arrays of single turn probes in a thick film format on a ceramic substrate as well as in a flexible cable format; however, such efforts inherently suffer from relatively large size requirements as well as sensitivity issues. Preliminary efforts to fully extend eddy current probing from a point or single dimensional level to a two dimensional micro-eddy current format on a silicon chip, which might overcome all of the above problems, are presented.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 11. (b) When impacted by a test probe conforming to § 572.21(a) at 13 fps in accordance with... parallel to the face of the test probe. (4) Place the longitudinal centerline of the test probe to coincide with the designated impact point and align the test probe so that at impact its longitudinal centerline...
Röder, Christoph; König, Helmut; Fröhlich, Jürgen
2007-09-01
Sequencing of the complete 26S rRNA genes of all Dekkera/Brettanomyces species colonizing different beverages revealed the potential for a specific primer and probe design to support diagnostic PCR approaches and FISH. By analysis of the complete 26S rRNA genes of all five currently known Dekkera/Brettanomyces species (Dekkera bruxellensis, D. anomala, Brettanomyces custersianus, B. nanus and B. naardenensis), several regions with high nucleotide sequence variability yet distinct from the D1/D2 domains were identified. FISH species-specific probes targeting the 26S rRNA gene's most variable regions were designed. Accessibility of probe targets for hybridization was facilitated by the construction of partially complementary 'side'-labeled probes, based on secondary structure models of the rRNA sequences. The specificity and routine applicability of the FISH-based method for yeast identification were tested by analyzing different wine isolates. Investigation of the prevalence of Dekkera/Brettanomyces yeasts in the German viticultural regions Wonnegau, Nierstein and Bingen (Rhinehesse, Rhineland-Palatinate) resulted in the isolation of 37 D. bruxellensis strains from 291 wine samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dimastrogiovanni, Emanuela; Emami, Razieh, E-mail: emanuela1573@gmail.com, E-mail: iasraziehm@ust.hk
Probing correlations among short and long-wavelength cosmological fluctuations is known to be decisive for deepening the current understanding of inflation at the microphysical level. Spectral distortions of the CMB can be caused by dissipation of cosmological perturbations when they re-enter Hubble after inflation. Correlating spectral distortions with temperature anisotropies will thus provide the opportunity to greatly enlarge the range of scales over which squeezed limits can be tested, opening up a new window on inflation complementing the ones currently probed with CMB and LSS. In this paper we discuss a variety of inflationary mechanisms that can be efficiently constrained withmore » distortion-temperature correlations. For some of these realizations (representative of large classes of models) we derive quantitative predictions for the squeezed limit bispectra, finding that their amplitudes are above the sensitivity limits of an experiment such as the proposed PIXIE.« less
Avoiding threat in late adulthood: testing two life span theories of emotion.
Orgeta, Vasiliki
2011-07-01
The purpose of the present research was to explore the time course of age-related attentional biases and the role of emotion regulation as a potential mediator of older adults' performance in an emotion dot probe task. In two studies, younger and older adults (N = 80) completed a visual probe detection task, which presented happy, angry, and sad facial expressions. Across both studies, age influenced attentional responses to angry faces. Results indicated a bias away from angry-related facial emotion information occurring relatively late in attention. Age effects were not attributable to decreasing information processing speed or visuoperceptual function. Current results demonstrated that an age-related attentional preference away from angry facial cues was mediated by efforts to suppress emotion. Findings are discussed in relation to current theories of sociocognitive aging.
A new evaluation method of electron optical performance of high beam current probe forming systems.
Fujita, Shin; Shimoyama, Hiroshi
2005-10-01
A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the 'threshold beam current I(th)' above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the 'electron gun focal length' as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current l(b) and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as d approximately I(b)(3/8), and (iii) the angular current intensity limited region in which the beam size increases rapidly as d approximately I(b)(3/2). Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.
Effects of Angular Variation on Split D Differential Eddy Current Probe Response (Postprint)
2016-02-10
AFRL-RX-WP-JA-2016-0327 EFFECTS OF ANGULAR VARIATION ON SPLIT D DIFFERENTIAL EDDY CURRENT PROBE RESPONSE (POSTPRINT) Ryan D...March 2014 – 22 September 2015 4. TITLE AND SUBTITLE EFFECTS OF ANGULAR VARIATION ON SPLIT D DIFFERENTIAL EDDY CURRENT PROBE RESPONSE (POSTPRINT...last few years have seen increased levels of complexity added to push the state-of-the-art modeling software used in eddy current NDE today. The added
Electron launching voltage monitor
Mendel, Clifford W.; Savage, Mark E.
1992-01-01
An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors.
NASA Astrophysics Data System (ADS)
Duma, V.-F.; Demian, D.; Sinescu, C.; Cernat, R.; Dobre, G.; Negrutiu, M. L.; Topala, F. I.; Hutiu, Gh.; Bradu, A.; Podoleanu, A. G.
2016-03-01
We present the handheld scanning probes that we have recently developed in our current project for biomedical imaging in general and for Optical Coherence Tomography (OCT) in particular. OCT is an established, but dynamic imagistic technique based on laser interferometry, which offers micrometer resolutions and millimeters penetration depths. With regard to existing devices, the newly developed handheld probes are simple, light and relatively low cost. Their design is described in detail to allow for the reproduction in any lab, including for educational purposes. Two probes are constructed almost entirely from off-the-shelf components, while a third, final variant is constructed with dedicated components, in an ergonomic design. The handheld probes have uni-dimensional (1D) galvanometer scanners therefore they achieve transversal sections through the biological sample investigated - in contrast to handheld probes equipped with bi-dimensional (2D) scanners that can also achieve volumetric (3D) reconstructions of the samples. These latter handheld probes are therefore also discussed, as well as the possibility to equip them with galvanometer 2D scanners or with Risley prisms. For galvanometer scanners the optimal scanning functions studied in a series of previous works are pointed out; these functions offer a higher temporal efficiency/duty cycle of the scanning process, as well as artifact-free OCT images. The testing of the handheld scanning probes in dental applications is presented, for metal ceramic prosthesis and for teeth.
Subminiature eddy current transducers for studying metal- dielectric junctions
NASA Astrophysics Data System (ADS)
Dmitriev, S.; Katasonov, A.; Malikov, V.; Sagalakov, A.; Davydchenko, M.; Shevtsova, L.; Ishkov, A.
2016-11-01
Based on an eddy current transducer (ECT), a probe has been designed to research metal-dielectric structures. The measurement procedure allowing one to detect defects in laminate composites with a high accuracy is described. The transducer was tested on the layered structure consisting of paper and aluminum layers with a thickness of 100 μm each in which the model defect was placed. The dependences of the ECT signal on the defect in this structure are given.
Farfield Plume Measurement and Analysis on the NASA-300M
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Shastry, Rohit; Soulas, George C.; Kamhawi, Hani
2013-01-01
NASA is developing a 15-kW Hall thruster to support future NASA missions. This activity is funded under the Space Technology Mission Directorate Solar Electric Propulsion Technology Demonstration project. As a part of the development process, the far-field plume characteristics of the NASA-300M, a 20-kW Hall thruster, were studied. The results will be used to study how various aspects of the operation of this thruster affect the overall performance. This data will be used to guide future design work and serve as a baseline for comparison to a magnetically shielded version of the NASA-300M that will be tested in the future. For this study, a far-field Faraday probe was swept in a polar fashion to map the ion current density. An ExB probe (Wien filter), two retarding potential analyzers, and a Langmuir probe were mounted at a fixed location on the thruster axis in the far-field plume. The data reduction method followed recommendations in recent studies by Brown, Reid, and Shastry with modifications that are tailored to the plasma plume environment of high-power Hall thrusters. Results from this and prior testing show that the plume is richer in doubly-charged ions, larger in spatial extent, and capable of greater probe heating than lower power thrusters. These characteristics require special treatment in experimental setup and data analysis, which will be the main focus of this paper. In particular, covered topics will include a new, more accurate, method of integration for analysis of the ExB probe data and effect of secondary electron emission on the Faraday probe data.
Failure analysis on false call probe pins of microprocessor test equipment
NASA Astrophysics Data System (ADS)
Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.
2017-09-01
A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.
New type of eddy current sensor for large-displacement test
NASA Astrophysics Data System (ADS)
Pan, Haifeng; Zhu, Huizhong; Fu, Zhibin; Xu, Yuzheng; Feng, Guanping
2001-09-01
In this paper a new type of large displacement eddy current sensor is developed to overcome the three main disadvantages of the traditional eddy current senor. For a traditional sensor, the measurement range is limited and less than one half of the diameter of the measuring coil. The output is high sensitivity to the changes of the target material and the cable length connected between the probe and the preamplifier. When the material or the cable length changed, it is necessary to readjust the preamplifier. The probe of the new eddy current sensor has three coaxial measuring coils, one is an exciting coil and the other two are receiving coils. The diameter of measuring coils is (Phi) 11 mm. The measurement range of this sensor is 40mm and almost four times of the diameter of the coil. The form of differential input and feedback amplification is used in signal amplifier. Thus the effect of the common modules, such as the changes of the target material and the cable length, can be counteracted well.
Feasibility of a GNSS-Probe for Creating Digital Maps of High Accuracy and Integrity
NASA Astrophysics Data System (ADS)
Vartziotis, Dimitris; Poulis, Alkis; Minogiannis, Alexandros; Siozos, Panayiotis; Goudas, Iraklis; Samson, Jaron; Tossaint, Michel
The “ROADSCANNER” project addresses the need for increased accuracy and integrity Digital Maps (DM) utilizing the latest developments in GNSS, in order to provide the required datasets for novel applications, such as navigation based Safety Applications, Advanced Driver Assistance Systems (ADAS) and Digital Automotive Simulations. The activity covered in the current paper is the feasibility study, preliminary tests, initial product design and development plan for an EGNOS enabled vehicle probe. The vehicle probe will be used for generating high accuracy, high integrity and ADAS compatible digital maps of roads, employing a multiple passes methodology supported by sophisticated refinement algorithms. Furthermore, the vehicle probe will be equipped with pavement scanning and other data fusion equipment, in order to produce 3D road surface models compatible with standards of road-tire simulation applications. The project was assigned to NIKI Ltd under the 1st Call for Ideas in the frame of the ESA - Greece Task Force.
The STPX Spheromak System: Recent Measurements and Observations
NASA Astrophysics Data System (ADS)
Williams, R. L.; Clark, J.; Richardson, M.; Williams, R. E.
2016-10-01
We present results of recent measurements made to characterize the plasma formed in the STPX* Spheromak plasma device installed at the Florida A. and M University. The toroidal plasma is formed using a pulsed cylindrical gun discharge and, when fully operational, is designed to approach a density of 1021 /m3 and electron temperatures in the range of 100-350 eV. The diagnostic devices used for these recent measurements include Langmuir probes, electrostatic triple probes, optical spectrometers, CCD detectors, laser probes and magnetic field coils. These probes have been tested using both a static and the pulsed discharges created in the device, and we report the latest measurements. The voltage and current profiles of the pulsed discharge as well as the pulsed magnetic field coils are discussed. Progress in modeling this spheromak using NIMROD and other simulation codes will be discussed. Our recent results of an ongoing study of the topology of magnetic helicity are presented in a separate poster. Spheromak Turbulent Physics Experiment.
Eddy current probe response to open and closed surface flaws
NASA Technical Reports Server (NTRS)
Auld, B. A.; Muennemann, F.; Winslow, D. K.
1981-01-01
A general analysis of eddy current response to certain types of open and closed surface flaws is presented for both standard low-frequency and ferromagnetic-resonance (FMR) probes. It is shown analytically that for two-dimensional and three-dimensional surface flaws interrogated by a uniform probe field, the crack opening sensitivity increases with the operating frequency of the probe, this behavior being due to the Faraday induction effect. Experiments with low-frequency probes operating at or below 1 MHz and with the FMR probe operating at approximately 1000 MHz confirm this increase of the crack mouth opening displacement for practical situations where the probe field is not uniform in the vicinity of the flaw.
Chapin, Kimberle C.; Blake, Patricia; Wilson, Claire D.
2002-01-01
Group A streptococcus (GAS) antigen testing has become a routine point-of-care (POC) test in acute care settings. Concern about performance parameters (PP) of these tests as well as inappropriate antibiotic use has resulted in various recommendations regarding diagnosis of GAS. There were two objectives in this study. The first was to evaluate the rapid GAS antigen test presently in use (Thermo BioStar, Boulder, Colo.) and the GAS Direct probe test (Gen-Probe, San Diego, Calif.) compared to culture. The second was to define the optimal use of these technologies in a large acute care pediatric clinic. A total of 520 consecutive pediatric patients presenting with symptoms of pharyngitis at any of three Lahey Clinic acute care facilities were evaluated. Pharyngeal specimens were collected using a double-swab collection device (Copan, Corona, Calif.). One swab was used for the antigen test, the second was used for the probe test, and the pledget was placed in the collection device for culture on 5% sheep blood agar, incubated for 48 h anaerobically, and subsequently placed in Todd-Hewitt broth. After discrepant analysis, sensitivity, specificity, and positive and negative predictive values were as follows: 94.8, 100, 100, and 96.9% for the probe test and 86.1, 97.1, 93.7, and 93.4% for the antigen test, respectively. Sensitivity using an enhanced culture technique was 99.4% (163 of 164). False-positive (FP) antigen results were often seen from patients previously diagnosed and/or treated for GAS. No FP results were seen with the probe test. Colony counts for the false-negative (FN) antigen tests were higher than those for the FN probe tests. Compared to culture and DNA probe, the rapid antigen test (RAT) offered a result at the time of the patient's visit, with acceptable PP when prevalence of disease is high. Follow-up testing with the RAT of GAS patients who previously tested as positive should be avoided due to increased FP results. The probe test was comparable to culture in performance. Results indicate the probe test can be used as the primary test or as a backup to negative antigen tests. The probe test offers the advantage over culture of same-day reporting of a final result but, in contrast to a POC test, necessitates follow-up communication to the patient. Preliminary data show the specificity of the probe test to be greater than that of the RAT for patients previously diagnosed with GAS. PMID:12409399
NASA Astrophysics Data System (ADS)
Bingham, S.; Mouikis, C.; Kistler, L. M.; Fok, M. C. H.; Glocer, A.; Farrugia, C. J.; Gkioulidou, M.; Spence, H. E.
2016-12-01
The ring current responds differently to the different solar and interplanetary storm drivers such as coronal mass injections, (CMEs), and co-rotating interaction regions (CIRs). Delineating the differences in the ring current development between these two drivers will aid our understanding of the ring current dynamics. Using Van Allen Probes observations, we develop an empirical ring current model of the ring current pressure, the pressure anisotropy and the current density development during the storm phases for both types of storm drivers and for all MLTs inside L 6. In addition, we identify the populations (energy and species) responsible. We find that during the storm main phase and the early recovery phase the plasma sheet particles (10-80 keV) convecting from the nightside contribute the most on the ring current pressure and current density. However, during these phases, the main difference between CMEs and CIRs is in the O+ contribution. This empirical model is compared to the results of CIMI simulations of CMEs and CIRs where the model input is comprised of the superposed epoch solar wind conditions of the storms that comprise the empirical model, while different inner magnetosphere boundary conditions will be tested in order to match the empirical model results. Comparing the model and simulation results will fill our understanding of the ring current dynamics as part of the highly coupled inner magnetosphere system.
Spatially-Resolved Beam Current and Charge-State Distributions for the NEXT Ion Engine
NASA Technical Reports Server (NTRS)
Pollard, James E.; Diamant, Kevin D.; Crofton, Mark W.; Patterson, Michael J.; Soulas, George C.
2010-01-01
Plume characterization tests with the 36-cm NEXT ion engine are being performed at The Aerospace Corporation using engineering-model and prototype-model thrusters. We have examined the beam current density and xenon charge-state distribution as functions of position on the accel grid. To measure the current density ratio j++/j+, a collimated Eprobe was rotated through the plume with the probe oriented normal to the accel electrode surface at a distance of 82 cm. The beam current density jb versus radial position was measured with a miniature planar probe at 3 cm from the accel. Combining the j++/j+ and jb data yielded the ratio of total Xe+2 current to total Xe+1 current (J++/J+) at forty operating points in the standard throttle table. The production of Xe+2 and Xe+3 was measured as a function of propellant utilization to support performance and lifetime predictions for an extended throttle table. The angular dependence of jb was measured at intermediate and far-field distances to assist with plume modeling and to evaluate the thrust loss due to beam divergence. Thrust correction factors were derived from the total doubles-to-singles current ratio and from the far-field divergence data
Pump-Probe Noise Spectroscopy of Molecular Junctions.
Ochoa, Maicol A; Selzer, Yoram; Peskin, Uri; Galperin, Michael
2015-02-05
The slow response of electronic components in junctions limits the direct applicability of pump-probe type spectroscopy in assessing the intramolecular dynamics. Recently the possibility of getting information on a sub-picosecond time scale from dc current measurements was proposed. We revisit the idea of picosecond resolution by pump-probe spectroscopy from dc measurements and show that any intramolecular dynamics not directly related to charge transfer in the current direction is missed by current measurements. We propose a pump-probe dc shot noise spectroscopy as a suitable alternative. Numerical examples of time-dependent and average responses of junctions are presented for generic models.
Electron launching voltage monitor
Mendel, C.W.; Savage, M.E.
1992-03-17
An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.
Numerical Tests of the Cosmic Censorship Conjecture via Event-Horizon Finding
NASA Astrophysics Data System (ADS)
Okounkova, Maria; Ott, Christian; Scheel, Mark; Szilagyi, Bela
2015-04-01
We present the current state of our research on the possibility of naked singularity formation in gravitational collapse, numerically testing both the cosmic censorship conjecture and the hoop conjecture. The former of these posits that all singularities lie behind an event horizon, while the later conjectures that this is true if collapse occurs from an initial configuration with all circumferences C <= 4 πM . We reconsider the classical Shapiro & Teukolsky (1991) prolate spheroid naked singularity scenario. Using the exponentially error-convergent Spectral Einstein Code (SpEC) we simulate the collapse of collisionless matter and probe for apparent horizons. We propose a new method to probe for the existence of an event horizon by following characteristic from regions near the singularity, using methods commonly employed in Cauchy characteristic extraction. This research was partially supported by NSF under Award No. PHY-1404569.
Tube cutter tool and method of use for coupon removal
Nachbar, H.D.; Etten, M.P. Jr.; Kurowski, P.A.
1997-05-06
A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place. 4 figs.
Tube cutter tool and method of use for coupon removal
Nachbar, Henry D.; Etten, Jr., Marvin P.; Kurowski, Paul A.
1997-01-01
A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place.
Calibrating CHIME: a new radio interferometer to probe dark energy
NASA Astrophysics Data System (ADS)
Newburgh, Laura B.; Addison, Graeme E.; Amiri, Mandana; Bandura, Kevin; Bond, J. Richard; Connor, Liam; Cliche, Jean-François; Davis, Greg; Deng, Meiling; Denman, Nolan; Dobbs, Matt; Fandino, Mateus; Fong, Heather; Gibbs, Kenneth; Gilbert, Adam; Griffin, Elizabeth; Halpern, Mark; Hanna, David; Hincks, Adam D.; Hinshaw, Gary; Höfer, Carolin; Klages, Peter; Landecker, Tom; Masui, Kiyoshi; Parra, Juan Mena; Pen, Ue-Li; Peterson, Jeff; Recnik, Andre; Shaw, J. Richard; Sigurdson, Kris; Sitwell, Micheal; Smecher, Graeme; Smegal, Rick; Vanderlinde, Keith; Wiebe, Don
2014-07-01
The Canadian Hydrogen Intensity Mapping Experiment (CHIME) is a transit interferometer currently being built at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, BC, Canada. We will use CHIME to map neutral hydrogen in the frequency range 400 { 800MHz over half of the sky, producing a measurement of baryon acoustic oscillations (BAO) at redshifts between 0.8 { 2.5 to probe dark energy. We have deployed a pathfinder version of CHIME that will yield constraints on the BAO power spectrum and provide a test-bed for our calibration scheme. I will discuss the CHIME calibration requirements and describe instrumentation we are developing to meet these requirements.
NASA Astrophysics Data System (ADS)
Mukherjee, Saptarshi; Rosell, Anders; Udpa, Lalita; Udpa, Satish; Tamburrino, Antonello
2017-02-01
The modeling of U-Bend segment in steam generator tubes for predicting eddy current probe signals from cracks, wear and pitting in this region poses challenges and is non-trivial. Meshing the geometry in the cartesian coordinate system might require a large number of elements to model the U-bend region. Also, since the lift-off distance between the probe and tube wall is usually very small, a very fine mesh is required near the probe region to accurately describe the eddy current field. This paper presents a U-bend model using differential geometry principles that exploit the result that Maxwell's equations are covariant with respect to changes of coordinates and independent of metrics. The equations remain unaltered in their form, regardless of the choice of the coordinates system, provided the field quantities are represented in the proper covariant and contravariant form. The complex shapes are mapped into simple straight sections, while small lift-off is mapped to larger values, thus reducing the intrinsic dimension of the mesh and stiffness matrix. In this contribution, the numerical implementation of the above approach will be discussed with regard to field and current distributions within the U-bend tube wall. For the sake of simplicity, a two dimensional test case will be considered. The approach is evaluated in terms of efficiency and accuracy by comparing the results with that obtained using a conventional FE model in cartesian coordinates.
P11, A Biomarker for Memory Retrieval: A Possible Role in Traumatic Stress
2014-10-01
experiments based on the proposed research design . We tested memory retrieval performance with wild type and p11 knockout mice, which developed and...not different on the final day of training or probe test . We also found that corticosterone resulted in significant decreases in the time spent in...mechanism of underlying memory and p11 in stress and fill a knowledge gap in the current research on PTSD. Such knowledge may facilitate the
Patil, A A; Yamanashi, W
1994-10-01
A new cautery system known as the electroconvergent cautery system is described. This cautery system uses a radiofrequency current of 13.56 MHz. The current is passed through an amplifier, an impedance matching system, and a loading and tuning coil into a probe. After the probe tip is touched to the tissue, the mismatch of impedance between the probe tip and the generator is minimized to almost zero, resulting in high-current density at the probe tip, which causes pinpoint heating of the tissue at the point where it is touched by the probe without spread of heat to the surrounding tissue. This heat can cut and vaporize tissue and coagulate vessels. The probe can also be used to coagulate vessels with standard surgical forceps. Because convergence of energy is used for tissue heating, a grounding pad is not needed. The system can also be used under cerebrospinal fluid or saline.
Impedance properties of circular microstrip antenna
NASA Technical Reports Server (NTRS)
Deshpande, M. D.; Bailey, M. C.
1983-01-01
A moment method solution to the input impedance of a circular microstrip antenna excited by either a microstrip feed or a coaxial probe is presented. Using the exact dyadic Green's function and the Fourier transform the problem is formulated in terms of Richmond's reaction integral equation from which the unknown patch current can be solved for. The patch current is expanded in terms of regular surface patch modes and an attachment mode (for probe excited case) which insures continuity of the current at probe/patch junction, proper polarization and p-dependance of patch current in the vicinity of the probe. The input impedance of a circular microstrip antenna is computed and compared with earlier results. Effect of attachment mode on the input impedance is also discussed.
Energetic Proton Spectra Measured by the Van Allen Probes
NASA Astrophysics Data System (ADS)
Summers, Danny; Shi, Run; Engebretson, Mark J.; Oksavik, Kjellmar; Manweiler, Jerry W.; Mitchell, Donald G.
2017-10-01
We test the hypothesis that pitch angle scattering by electromagnetic ion cyclotron (EMIC) waves can limit ring current proton fluxes. For two chosen magnetic storms, during 17-20 March 2013 and 17-20 March 2015, we measure proton energy spectra in the region 3 ≤ L ≤ 6 using the RBSPICE-B instrument on the Van Allen Probes. The most intense proton spectra are observed to occur during the recovery periods of the respective storms. Using proton precipitation data from the POES (NOAA and MetOp) spacecraft, we deduce that EMIC wave action was prevalent at the times and L-shell locations of the most intense proton spectra. We calculate limiting ring current proton energy spectra from recently developed theory. Comparisons between the observed proton energy spectra and the theoretical limiting spectra show reasonable agreement. We conclude that the measurements of the most intense proton spectra are consistent with self-limiting by EMIC wave scattering.
Overview of Probe-based Storage Technologies
NASA Astrophysics Data System (ADS)
Wang, Lei; Yang, Ci Hui; Wen, Jing; Gong, Si Di; Peng, Yuan Xiu
2016-07-01
The current world is in the age of big data where the total amount of global digital data is growing up at an incredible rate. This indeed necessitates a drastic enhancement on the capacity of conventional data storage devices that are, however, suffering from their respective physical drawbacks. Under this circumstance, it is essential to aggressively explore and develop alternative promising mass storage devices, leading to the presence of probe-based storage devices. In this paper, the physical principles and the current status of several different probe storage devices, including thermo-mechanical probe memory, magnetic probe memory, ferroelectric probe memory, and phase-change probe memory, are reviewed in details, as well as their respective merits and weakness. This paper provides an overview of the emerging probe memories potentially for next generation storage device so as to motivate the exploration of more innovative technologies to push forward the development of the probe storage devices.
Overview of Probe-based Storage Technologies.
Wang, Lei; Yang, Ci Hui; Wen, Jing; Gong, Si Di; Peng, Yuan Xiu
2016-12-01
The current world is in the age of big data where the total amount of global digital data is growing up at an incredible rate. This indeed necessitates a drastic enhancement on the capacity of conventional data storage devices that are, however, suffering from their respective physical drawbacks. Under this circumstance, it is essential to aggressively explore and develop alternative promising mass storage devices, leading to the presence of probe-based storage devices. In this paper, the physical principles and the current status of several different probe storage devices, including thermo-mechanical probe memory, magnetic probe memory, ferroelectric probe memory, and phase-change probe memory, are reviewed in details, as well as their respective merits and weakness. This paper provides an overview of the emerging probe memories potentially for next generation storage device so as to motivate the exploration of more innovative technologies to push forward the development of the probe storage devices.
Recent and Future Enhancements in NDI for Aircraft Structures
2015-11-30
accomplish NDI of aircraft structure. This includes improved eddy current probes, improved eddy current instrumentation, as well as other...Aircraft Structures,” which is currently in Revision C [8]. The document divides various inspection methods, such as eddy current and fluorescent...efforts at AFRL to address technology shortfalls include improved eddy current probes, improved eddy current instrumentation, as well as other
Recent and Future Enhancements in NDI for Aircraft Structures (Postprint)
2015-11-30
accomplish NDI of aircraft structure. This includes improved eddy current probes, improved eddy current instrumentation, as well as other...Aircraft Structures,” which is currently in Revision C [8]. The document divides various inspection methods, such as eddy current and fluorescent...efforts at AFRL to address technology shortfalls include improved eddy current probes, improved eddy current instrumentation, as well as other
Recent and Future Enhancements in NDI for Aircraft Structures (Postprint)
2015-11-01
accomplish NDI of aircraft structure. This includes improved eddy current probes, improved eddy current instrumentation, as well as other...Aircraft Structures,” which is currently in Revision C [8]. The document divides various inspection methods, such as eddy current and fluorescent...efforts at AFRL to address technology shortfalls include improved eddy current probes, improved eddy current instrumentation, as well as other
Recent and Future Enhancements in NDI for Aircraft Structures (POSTPRINT)
2015-11-16
accomplish NDI of aircraft structure. This includes improved eddy current probes, improved eddy current instrumentation, as well as other...Aircraft Structures,” which is currently in Revision C [8]. The document divides various inspection methods, such as eddy current and fluorescent...efforts at AFRL to address technology shortfalls include improved eddy current probes, improved eddy current instrumentation, as well as other
Kuwata, Tomoyuki; Takahashi, Hironori; Koibuchi, Harumi; Ichizuka, Kiyotake; Natori, Michiya; Matsubara, Shigeki
2016-10-01
To clarify the present status of human papillomavirus (HPV) contamination of transvaginal probes in Japan and propose a preventive method. This study was performed at three institutes: a tertiary center, secondary hospital, and primary facility. To identify contamination rates, probes were disinfected and covered with probe covers and condoms; the cover was changed for each patient. The probes were tested for HPV, and those with HPV detected were analyzed to identify the type of HPV. Next, nurses put on new gloves before covering the probe for each patient, and the probes were similarly tested for HPV. A total of 120 probes were tested, and HPV was detected from a total of five probes, a contamination rate of 4.2 % (5/120). HPV was detected in all three institutes. Importantly, high-risk HPV, i.e., HPV-52, 56, and 59, was detected. After the "glove change strategy" was implemented, HPV was not detected on any of 150 probes tested at any of the three institutions. In Japan, the HPV contamination rate of vaginal probes in routine practice was 4.2 %. There was no HPV contamination of probes after changing the gloves for cover exchange for each patient. This strategy may prevent HPV probe contamination.
NASA Technical Reports Server (NTRS)
Chen, Erinna M.
2005-01-01
A significant problem in the use of electric thrusters in spacecraft is the formation of low-energy ions in the thruster plume. Low-energy ions are formed in the plume via random collisions between high-velocity ions ejected from the thruster and slow-moving neutral atoms of propellant effusing from the engine. The sputtering of spacecraft materials due to interactions with low-energy ions may result in erosion or contamination of the spacecraft. The trajectory of these ions is determined primarily by the plasma potential of the plume. Thus, accurate characterization of the plasma potential is essential to predicting low-energy ion contamination. Emissive probes were utilized to determine the plasma potential. When the ion and electron currents to the probe are balanced, the potential of such probes float to the plasma potential. Two emissive probes were fabricated; one utilizing a DC power supply, another utilizing a rectified AC power source. Labview programs were written to coordinate and automate probe motion in the thruster plume. Employing handshaking interaction, these motion programs were synchronized to various data acquisition programs to ensure precision and accuracy of the measurements. Comparing these experimental values to values from theoretical models will allow for a more accurate prediction of low-energy ion interaction.
Cross-scale observations of the 2015 St. Patrick's day storm: THEMIS, Van Allen Probes, and TWINS
Goldstein, J.; Angelopoulos, V.; De Pascuale, S.; ...
2016-12-10
In this paper, we present cross-scale magnetospheric observations of the 17 March 2015 (St. Patrick's Day) storm, by Time History of Events and Macroscale Interactions during Substorms (THEMIS), Van Allen Probes (Radiation Belt Storm Probes), and Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS), plus upstream ACE/Wind solar wind data. THEMIS crossed the bow shock or magnetopause 22 times and observed the magnetospheric compression that initiated the storm. Empirical models reproduce these boundary locations within 0.7 R E. Van Allen Probes crossed the plasmapause 13 times; test particle simulations reproduce these encounters within 0.5 R E. Before the storm, Van Allen Probesmore » measured quiet double-nose proton spectra in the region of corotating cold plasma. About 15 min after a 0605 UT dayside southward turning, Van Allen Probes captured the onset of inner magnetospheric convection, as a density decrease at the moving corotation-convection boundary (CCB) and a steep increase in ring current (RC) proton flux. During the first several hours of the storm, Van Allen Probes measured highly dynamic ion signatures (numerous injections and multiple spectral peaks). Sustained convection after ~1200 UT initiated a major buildup of the midnight-sector ring current (measured by RBSP A), with much weaker duskside fluxes (measured by RBSP B, THEMIS a and THEMIS d). A close conjunction of THEMIS d, RBSP A, and TWINS 1 at 1631 UT shows good three-way agreement in the shapes of two-peak spectra from the center of the partial RC. A midstorm injection, observed by Van Allen Probes and TWINS at 1740 UT, brought in fresh ions with lower average energies (leading to globally less energetic spectra in precipitating ions) but increased the total pressure. Finally, the cross-scale measurements of 17 March 2015 contain significant spatial, spectral, and temporal structure.« less
Cross-scale observations of the 2015 St. Patrick's day storm: THEMIS, Van Allen Probes, and TWINS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldstein, J.; Angelopoulos, V.; De Pascuale, S.
In this paper, we present cross-scale magnetospheric observations of the 17 March 2015 (St. Patrick's Day) storm, by Time History of Events and Macroscale Interactions during Substorms (THEMIS), Van Allen Probes (Radiation Belt Storm Probes), and Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS), plus upstream ACE/Wind solar wind data. THEMIS crossed the bow shock or magnetopause 22 times and observed the magnetospheric compression that initiated the storm. Empirical models reproduce these boundary locations within 0.7 R E. Van Allen Probes crossed the plasmapause 13 times; test particle simulations reproduce these encounters within 0.5 R E. Before the storm, Van Allen Probesmore » measured quiet double-nose proton spectra in the region of corotating cold plasma. About 15 min after a 0605 UT dayside southward turning, Van Allen Probes captured the onset of inner magnetospheric convection, as a density decrease at the moving corotation-convection boundary (CCB) and a steep increase in ring current (RC) proton flux. During the first several hours of the storm, Van Allen Probes measured highly dynamic ion signatures (numerous injections and multiple spectral peaks). Sustained convection after ~1200 UT initiated a major buildup of the midnight-sector ring current (measured by RBSP A), with much weaker duskside fluxes (measured by RBSP B, THEMIS a and THEMIS d). A close conjunction of THEMIS d, RBSP A, and TWINS 1 at 1631 UT shows good three-way agreement in the shapes of two-peak spectra from the center of the partial RC. A midstorm injection, observed by Van Allen Probes and TWINS at 1740 UT, brought in fresh ions with lower average energies (leading to globally less energetic spectra in precipitating ions) but increased the total pressure. Finally, the cross-scale measurements of 17 March 2015 contain significant spatial, spectral, and temporal structure.« less
NASA Astrophysics Data System (ADS)
Kazemiroodsari, Hadi
Liquefaction is loss of shear strength in fully saturated loose sands caused by build-up of excess pore water pressure, during moderate to large earthquakes, leading to catastrophic failures of structures. Currently used liquefaction mitigation measures are often costly and cannot be applied at sites with existing structures. An innovative, practical, and cost effective liquefaction mitigation technique titled "Induced Partial Saturation" (IPS) was developed by researchers at Northeastern University. The IPS technique is based on injection of sodium percarbonate solution into fully saturated liquefaction susceptible sand. Sodium percarbonate dissolves in water and breaks down into sodium and carbonate ions and hydrogen peroxide which generates oxygen gas bubbles. Oxygen gas bubbles become trapped in sand pores and therefore decrease the degree of saturation of the sand, increase the compressibility of the soil, thus reduce its potential for liquefaction. The implementation of IPS required the development and validation of a monitoring and evaluation technique that would help ensure that the sands are indeed partially saturated. This dissertation focuses on this aspect of the IPS research. The monitoring system developed was based on using electric conductivity fundamentals and probes to detect the transport of chemical solution, calculate degree of saturation of sand, and determine the final zone of partial saturation created by IPS. To understand the fundamentals of electric conductivity, laboratory bench-top tests were conducted using electric conductivity probes and small specimens of Ottawa sand. Bench-top tests were used to study rate of generation of gas bubbles due to reaction of sodium percarbonate solution in sand, and to confirm a theory based on which degree of saturation were calculated. In addition to bench-top tests, electric conductivity probes were used in a relatively large sand specimen prepared in a specially manufactured glass tank. IPS was implemented in the prepared specimen to validate the numerical simulation model and explore the use of conductivity probes to detect the transport of chemical solution, estimate degree of saturation achieved due to injection of chemical solution, and evaluate final zone of partial saturation. The conductivity probe and the simulation results agreed well. To study the effect of IPS on liquefaction response of the sand specimen, IPS was implemented in a large (2-story high) sand specimen prepared in the laminar box of NEES Buffalo and then the specimen was subjected to harmonic shaking. Electric conductivity probes were used in the specimen treatment by controlling the duration and spacing of injection of the chemical solution, in monitoring the transport of chemical solution, in the estimation of zone of partial saturation achieved, and in the estimation of degree of saturation achieved due to implementation of IPS. The conductivity probes indicated partial saturation of the specimen. The shaking tests results confirmed the partial saturation state of the sand specimen. In addition, to the laboratory works, electric conductivity probes were used in field implementation of IPS in a pilot test at the Wildlife Liquefaction Array (WLA) of NEES UCSB site. The conductivity probes in the field test helped decide the optimum injection pressure, the injection tube spacing, and the degree of saturation that could be achieved in the field. The various laboratory and field tests confirmed that electric conductivity and the probes devised and used can be invaluable in the implementation of IPS, by providing information regarding transport of the chemical solution, the spacing of injection tubes, duration of injection, and the zone and degree of partial saturation caused by IPS.
NASA Astrophysics Data System (ADS)
Lüpke, Felix; Cuma, David; Korte, Stefan; Cherepanov, Vasily; Voigtländer, Bert
2018-02-01
We present a four-point probe resistance measurement technique which uses four equivalent current measuring units, resulting in minimal hardware requirements and corresponding sources of noise. Local sample potentials are measured by a software feedback loop which adjusts the corresponding tip voltage such that no current flows to the sample. The resulting tip voltage is then equivalent to the sample potential at the tip position. We implement this measurement method into a multi-tip scanning tunneling microscope setup such that potentials can also be measured in tunneling contact, allowing in principle truly non-invasive four-probe measurements. The resulting measurement capabilities are demonstrated for \
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Motion of Test Probe Arrested by Simultaneous Contact With Both Sides of âAâ Section of Probe and Boundaries of Opening 3 Figure 3 to Part 1513... REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 3 Figure 3 to Part 1513—Motion of Test Probe Arrested by Simultaneous...
Favril, Sophie; Abma, Eline; Blasi, Francesco; Stock, Emmelie; Devriendt, Nausikaa; Vanderperren, Katrien; de Rooster, Hilde
2018-04-28
One of the major challenges in surgical oncology is the intraoperative discrimination of tumoural versus healthy tissue. Until today, surgeons rely on visual inspection and palpation to define the tumoural margins during surgery and, unfortunately, for various cancer types, the local recurrence rate thus remains unacceptably high. Near-infrared (NIR) fluorescence imaging is an optical imaging technique that can provide real-time preoperative and intraoperative information after administration of a fluorescent probe that emits NIR light once exposed to a NIR light source. This technique is safe, cost-effective and technically easy. Several NIR fluorescent probes are currently studied for their ability to highlight neoplastic cells. In addition, NIR fluorescence imaging holds great promise for sentinel lymph node mapping. The aim of this manuscript is to provide a literature review of the current organic NIR fluorescent probes tested in the light of human oncology and to introduce fluorescence imaging as a valuable asset in veterinary oncology. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Magnetic measurements of the 10 T superconducting wiggler for the SPring-8 storage ring
NASA Astrophysics Data System (ADS)
Batrakov, A.; Borovikov, V.; Bekhtenev, E.; Fedurin, M.; Hara, M.; Karpov, G.; Kuzin, M.; Mezentsev, N.; Miahara, Y.; Shimada, T.; Shkaruba, V.; Soutome, K.; Tzumaki, K.
2001-07-01
In 1999, in the frame of the project ISTC #767 "Budker INP/RIKEN Slow Positron Source", the Budker Institute of Nuclear Physics had made a 10 T Three-pole Superconducting Wiggler. The wiggler will be the keystone of this project by its installation on the SPring-8 storage ring for powerful gamma ray generation ( λ c=450 keV ), that will be used for slow positron production ( Nγ( ɛ>1 MeV)˜10 15, γ/s I e=0.1 A ). A. Ando et al., Proposal of the high magnetic field super conducting WLS for slow positron source at SPring-8, presented at SR1 '97 Conference. In January, 2000, the wiggler was transported to SPring-8, where the last test and measurements were carried out in collaboration with Japan. In this article, the results of measurements of the magnetic field, finding the magnetic field amplitude by an NMR probe, the definition of feed current relations by stretch current wire method, the calibration of a Hall probe in the high magnetic field, and the measurement of the magnetic field profile by a Hall probe are presented.
LaBombard, B; Lyons, L
2007-07-01
A new method for the real-time evaluation of the conditions in a magnetized plasma is described. The technique employs an electronic "mirror Langmuir probe" (MLP), constructed from bipolar rf transistors and associated high-bandwidth electronics. Utilizing a three-state bias wave form and active feedback control, the mirror probe's I-V characteristic is continuously adjusted to be a scaled replica of the "actual" Langmuir electrode immersed in a plasma. Real-time high-bandwidth measurements of the plasma's electron temperature, ion saturation current, and floating potential can thereby be obtained using only a single electrode. Initial tests of a prototype MLP system are reported, proving the concept. Fast-switching metal-oxide-semiconductor field-effect transistors produce the required three-state voltage bias wave form, completing a full cycle in under 1 mus. Real-time outputs of electron temperature, ion saturation current, and floating potential are demonstrated, which accurately track an independent computation of these values from digitally stored I-V characteristics. The MLP technique represents a significant improvement over existing real-time methods, eliminating the need for multiple electrodes and sampling all three plasma parameters at a single spatial location.
Day, Clifford K.; Stringer, James L.
1977-01-01
Apparatus for measuring displacements of core components of a liquid metal fast breeder reactor by means of an eddy current probe. The active portion of the probe is located within a dry thimble which is supported on a stationary portion of the reactor core support structure. Split rings of metal, having a resistivity significantly different than sodium, are fixedly mounted on the core component to be monitored. The split rings are slidably positioned around, concentric with the probe and symmetrically situated along the axis of the probe so that motion of the ring along the axis of the probe produces a proportional change in the probes electrical output.
Rotating concave eddy current probe
Roach, Dennis P [Albuquerque, NM; Walkington, Phil [Albuquerque, NM; Rackow, Kirk A [Albuquerque, NM; Hohman, Ed [Albuquerque, NM
2008-04-01
A rotating concave eddy current probe for detecting fatigue cracks hidden from view underneath the head of a raised head fastener, such as a buttonhead-type rivet, used to join together structural skins, such as aluminum aircraft skins. The probe has a recessed concave dimple in its bottom surface that closely conforms to the shape of the raised head. The concave dimple holds the probe in good alignment on top of the rivet while the probe is rotated around the rivet's centerline. One or more magnetic coils are rigidly embedded within the probe's cylindrical body, which is made of a non-conducting material. This design overcomes the inspection impediment associated with widely varying conductivity in fastened joints.
Unified Ultrasonic/Eddy-Current Data Acquisition
NASA Technical Reports Server (NTRS)
Chern, E. James; Butler, David W.
1993-01-01
Imaging station for detecting cracks and flaws in solid materials developed combining both ultrasonic C-scan and eddy-current imaging. Incorporation of both techniques into one system eliminates duplication of computers and of mechanical scanners; unifies acquisition, processing, and storage of data; reduces setup time for repetitious ultrasonic and eddy-current scans; and increases efficiency of system. Same mechanical scanner used to maneuver either ultrasonic or eddy-current probe over specimen and acquire point-by-point data. For ultrasonic scanning, probe linked to ultrasonic pulser/receiver circuit card, while, for eddy-current imaging, probe linked to impedance-analyzer circuit card. Both ultrasonic and eddy-current imaging subsystems share same desktop-computer controller, containing dedicated plug-in circuit boards for each.
Refinement of a thermal threshold probe to prevent burns.
Dixon, M J; Taylor, P M; Slingsby, L C; Murrell, J C
2016-02-01
Thermal threshold testing is commonly used for pain research. The stimulus may cause burning and merits prevention. Thermal probe modifications hypothesized to reduce burning were evaluated for practicality and effect. Studies were conducted on two humans and eight cats. Unmodified probe 0 was tested on two humans and promising modifications were also evaluated on cats. Probe 1 incorporated rapid cooling after threshold was reached: probe 1a used a Peltier system and probe 1b used water cooling. Probe 2 released skin contact immediately after threshold. Probe 3 (developed in the light of evidence of 'hot spots' in probe 0) incorporated reduced thermal mass and even heating across the skin contact area. Human skin was heated to 48℃ (6℃ above threshold) and the resulting burn was evaluated using area of injury and a simple descriptive scale (SDS). Probe 1a cooled the skin but required further heat dissipation, excessive power, was not 'fail-safe' and was inappropriate for animal mounting. Probe 1b caused less damage than no cooling (27 ± 13 and 38 ± 11 mm(2) respectively, P = 0.0266; median SDS 1.5 and 4 respectively, P = 0.0317) but was cumbersome. Probe 2 was unwieldy and was not evaluated further. Probe 3 produced even heating without blistering in humans. With probe 3 in cats, after opioid treatment, thermal threshold reached cut-out (55℃) on 24 occasions, exceeded 50℃ in a further 32 tests and exceeded 48℃ in the remainder. No skin damage was evident immediately after testing and mild hyperaemia in three cats at 2-3 days resolved rapidly. Probe 3 appeared to be suitable for thermal threshold testing. © The Author(s) 2015.
Handheld probe for portable high frame photoacoustic/ultrasound imaging system
NASA Astrophysics Data System (ADS)
Daoudi, K.; van den Berg, P. J.; Rabot, O.; Kohl, A.; Tisserand, S.; Brands, P.; Steenbergen, W.
2013-03-01
Photoacoustics is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophors. In current research, this technique uses large and costly photoacoustic systems with a low frame rate imaging. To open the door for widespread clinical use, a compact, cost effective and fast system is required. In this paper we report on the development of a small compact handset pulsed laser probe which will be connected to a portable ultrasound system for real-time photoacoustic imaging and ultrasound imaging. The probe integrates diode lasers driven by an electrical driver developed for very short high power pulses. It uses specifically developed highly efficient diode stacks with high frequency repetition rate up to 10 kHz, emitting at 800nm wavelength. The emitted beam is collimated and shaped with compact micro optics beam shaping system delivering a homogenized rectangular laser beam intensity distribution. The laser block is integrated with an ultrasound transducer in an ergonomically designed handset probe. This handset is a building block enabling for a low cost high frame rate photoacoustic and ultrasound imaging system. The probe was used with a modified ultrasound scanner and was tested by imaging a tissue mimicking phantom.
Capacitance-level/density monitor for fluidized-bed combustor
Fasching, George E.; Utt, Carroll E.
1982-01-01
A multiple segment three-terminal type capacitance probe with segment selection, capacitance detection and compensation circuitry and read-out control for level/density measurements in a fluidized-bed vessel is provided. The probe is driven at a high excitation frequency of up to 50 kHz to sense quadrature (capacitive) current related to probe/vessel capacitance while being relatively insensitive to the resistance current component. Compensation circuitry is provided for generating a negative current of equal magnitude to cancel out only the resistive component current. Clock-operated control circuitry separately selects the probe segments in a predetermined order for detecting and storing this capacitance measurement. The selected segment acts as a guarded electrode and is connected to the read-out circuitry while all unselected segments are connected to the probe body, which together form the probe guard electrode. The selected probe segment capacitance component signal is directed to a corresponding segment channel sample and hold circuit dedicated to that segment to store the signal derived from that segment. This provides parallel outputs for display, computer input, etc., for the detected capacitance values. The rate of segment sampling may be varied to either monitor the dynamic density profile of the bed (high sampling rate) or monitor average bed characteristics (slower sampling rate).
Development of a subsurface gas flow probe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cutler, R.P.; Ballard, S.; Barker, G.T.
1997-04-01
This report describes a project to develop a flow probe to monitor gas movement in the vadose zone due to passive venting or active remediation efforts such as soil vapor extraction. 3-D and 1-D probes were designed, fabricated, tested in known flow fields under laboratory conditions, and field tested. The 3-D pores were based on technology developed for ground water flow monitoring. The probes gave excellent agreement with measured air velocities in the laboratory tests. Data processing software developed for ground water flow probes was modified for use with air flow, and to accommodate various probe designs. Modifications were mademore » to decrease the cost of the probes, including developing a downhole multiplexer. Modeling indicated problems with flow channeling due to the mode of deployment. Additional testing was conducted and modifications were made to the probe and to the deployment methods. The probes were deployed at three test sites: a large outdoor test tank, a brief vapor extraction test at the Chemical Waste landfill, and at an active remediation site at a local gas station. The data from the field tests varied markedly from the laboratory test data. All of the major events such as vapor extraction system turn on and turn off, as well as changes in the flow rate, could be seen in the data. However, there were long term trends in the data which were much larger than the velocity signals, which made it difficult to determine accurate air velocities. These long term trends may be due to changes in soil moisture content and seasonal ground temperature variations.« less
Single point aerosol sampling: evaluation of mixing and probe performance in a nuclear stack.
Rodgers, J C; Fairchild, C I; Wood, G O; Ortiz, C A; Muyshondt, A; McFarland, A R
1996-01-01
Alternative reference methodologies have been developed for sampling of radionuclides from stacks and ducts, which differ from the methods previously required by the United States Environmental Protection Agency. These alternative reference methodologies have recently been approved by the U.S. EPA for use in lieu of the current standard techniques. The standard EPA methods are prescriptive in selection of sampling locations and in design of sampling probes whereas the alternative reference methodologies are performance driven. Tests were conducted in a stack at Los Alamos National Laboratory to demonstrate the efficacy of some aspects of the alternative reference methodologies. Coefficients of variation of velocity, tracer gas, and aerosol particle profiles were determined at three sampling locations. Results showed that numerical criteria placed upon the coefficients of variation by the alternative reference methodologies were met at sampling stations located 9 and 14 stack diameters from the flow entrance, but not at a location that was 1.5 diameters downstream from the inlet. Experiments were conducted to characterize the transmission of 10 microns aerodynamic diameter liquid aerosol particles through three types of sampling probes. The transmission ratio (ratio of aerosol concentration at the probe exit plane to the concentration in the free stream) was 107% for a 113 L min-1 (4-cfm) anisokinetic shrouded probe, but only 20% for an isokinetic probe that follows the existing EPA standard requirements. A specially designed isokinetic probe showed a transmission ratio of 63%. The shrouded probe performance would conform to the alternative reference methodologies criteria; however, the isokinetic probes would not.
Eddy-Current Inspection Of Graphite-Fiber Composites
NASA Technical Reports Server (NTRS)
Workman, G. L.; Bryson, C. C.
1993-01-01
NASA technical memorandum describes initial research on, and proposed development of, automated system for nondestructive eddy-current inspection of parts made of graphite-fiber/epoxy-matrix composite materials. Sensors in system E-shaped or U-shaped eddy-current probes like those described in "Eddy-Current Probes For Inspecting Graphite-Fiber Composites" (MFS-26129).
Type-specific proactive interference in patients with semantic and phonological STM deficits.
Harris, Lara; Olson, Andrew; Humphreys, Glyn
2014-01-01
Prior neuropsychological evidence suggests that semantic and phonological components of short-term memory (STM) are functionally and neurologically distinct. The current paper examines proactive interference (PI) from semantic and phonological information in two STM-impaired patients, DS (semantic STM deficit) and AK (phonological STM deficit). In Experiment 1 probe recognition tasks with open and closed sets of stimuli were used. Phonological PI was assessed using nonword items, and semantic and phonological PI was assessed using words. In Experiment 2 phonological and semantic PI was elicited by an item recognition probe test with stimuli that bore phonological and semantic relations to the probes. The data suggested heightened phonological PI for the semantic STM patient, and exaggerated effects of semantic PI in the phonological STM case. The findings are consistent with an account of extremely rapid decay of activated type-specific representations in cases of severely impaired phonological and semantic STM.
Milotti, Valeria; Pietsch, Manuel; Strunk, Karl-Philipp; Melzer, Christian
2018-01-01
We report a Kelvin-probe method to investigate the lateral charge-transport properties of semiconductors, most notably the charge-carrier mobility. The method is based on successive charging and discharging of a pre-biased metal-insulator-semiconductor stack by an alternating voltage applied to one edge of a laterally confined semiconductor layer. The charge carriers spreading along the insulator-semiconductor interface are directly measured by a Kelvin-probe, following the time evolution of the surface potential. A model is presented, describing the device response for arbitrary applied biases allowing the extraction of the lateral charge-carrier mobility from experimentally measured surface potentials. The method is tested using the organic semiconductor poly(3-hexylthiophene), and the extracted mobilities are validated through current voltage measurements on respective field-effect transistors. Our widely applicable approach enables robust measurements of the lateral charge-carrier mobility in semiconductors with weak impact from the utilized contact materials.
NASA Astrophysics Data System (ADS)
Milotti, Valeria; Pietsch, Manuel; Strunk, Karl-Philipp; Melzer, Christian
2018-01-01
We report a Kelvin-probe method to investigate the lateral charge-transport properties of semiconductors, most notably the charge-carrier mobility. The method is based on successive charging and discharging of a pre-biased metal-insulator-semiconductor stack by an alternating voltage applied to one edge of a laterally confined semiconductor layer. The charge carriers spreading along the insulator-semiconductor interface are directly measured by a Kelvin-probe, following the time evolution of the surface potential. A model is presented, describing the device response for arbitrary applied biases allowing the extraction of the lateral charge-carrier mobility from experimentally measured surface potentials. The method is tested using the organic semiconductor poly(3-hexylthiophene), and the extracted mobilities are validated through current voltage measurements on respective field-effect transistors. Our widely applicable approach enables robust measurements of the lateral charge-carrier mobility in semiconductors with weak impact from the utilized contact materials.
Plasma Flow During RF Discharges in VASIMR
NASA Technical Reports Server (NTRS)
Jacobson, V. T.; Chang Diaz, F. R.; Squire, J. P.; Ilin, A. V.; Bengtson, R. D.; Carter, M. D.; Goulding, R. H.
1999-01-01
The Variable Specific Impulse Magnetoplasma Rocket (VASIMR) plasma source consists of a helical antenna, driven at frequencies of 4 to 19 MHz with powers up to 1 kW, in a magnetic field up to 3 kG. Helium is the current test gas, and future experiments with hydrogen are planned. Plasma density and temperature profiles were measured by a reciprocating Langmuir probe, and plasma flow profiles were measured with a reciprocating Mach probe. Both probes were located about 0.5 m downstream from the helical antenna. The plasma source operated in capacitive and inductive modes in addition to a helicon mode. During capacitive and inductive modes, densities were low and plasma flow was < 0.5 Cs. When the plasma operated in a helicon mode, the densities measured downstream from the source were higher [10(exp 12) / cubic cm ] and plasma flow along the magnetic field was of the order Mach 1. Details of the measurements will be shown.
Test probe for surface mounted leadless chip carrier
Meyer, Kerry L.; Topolewski, John
1989-05-23
A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.
Test probe for surface mounted leadless chip carrier
Meyer, K.L.; Topolewski, J.
1987-10-02
A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.
Reid, Brian; Graue-Hernandez, Enrique O; Mannis, Mark J; Zhao, Min
2011-03-01
To measure electric current in human corneal wounds and test the feasibility of pharmacologically enhancing the current to promote corneal wound healing. Using a noninvasive vibrating probe, corneal electric current was measured before and after wounding of the epithelium of donated postmortem human corneas. The effects of drug aminophylline and chloride-free solution on wound current were also tested. Unwounded cornea had small outward currents (0.07 μA/cm²). Wounding increased the current more than 5 fold (0.41 μA/cm²). Monitoring the wound current over time showed that it seemed to be actively regulated and maintained above normal unwounded levels for at least 6 hours. The time course was similar to that previously measured in rat cornea. Drug treatment or chloride-free solution more than doubled the size of wound currents. Electric current at human corneal wounds can be significantly increased with aminophylline or chloride-free solution. Because corneal wound current directly correlates with wound healing rate, our results suggest a role for chloride-free and/or aminophylline eyedrops to enhance healing of damaged cornea in patients with reduced wound healing such as the elderly or diabetic patient. This novel approach offers bioelectric stimulation without electrodes and can be readily tested in patients.
Wafer-level radiometric performance testing of uncooled microbolometer arrays
NASA Astrophysics Data System (ADS)
Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl
2014-03-01
A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.
Iodine Plasma Species Measurements in a Hall Effect Thruster Plume
2013-05-01
with an ExB probe , an electrostatic analyzer (ESA), and a combined ESA/ExB probe . The distribution of xenon ions was also measured. Multiply charge...of iodine ions was measured with an ExB probe , an electrostatic analyzer (ESA), and a combined ESA/ExB probe . • Results: – Multiply charged species...Test Hardware – Vacuum test facility (6’ diameter) – Faraday probe (MIT) – ESA, ExB, ESA/ExB Probes (Plasma Controls) – Rotary probe arm (about
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
49 CFR 572.72 - Head assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... a test probe conforming to § 572.77(a)(1) at 7 feet per second (fps) according to the test procedure... the test probe so that its longitudinal center line is— (i) At the forehead at the point of orthogonal... and midsagittal planes passing through this point. (3) Impact the head with the test probe so that at...
Adaptive amplifier for probe diagnostics of charged-particle temperature in the upper atmosphere
NASA Astrophysics Data System (ADS)
Chkalov, V. G.
An amplifier for probe experiments in the upper atmosphere is described which is based on a linear current-voltage converter design. Specifically, the amplifier is used as the input unit in a rocket-borne ionospheric probe for the measurement of electron temperature. The range of measured currents is from 10 to the -10th to 10 to the -6th A; the amplifier current range can be shifted up or down depending on the requirements of the experiment.
Input impedance of coaxially fed rectangular microstrip antenna on electrically thick substrate
NASA Technical Reports Server (NTRS)
Chen, Wei; Lee, Kai-Fong; Lee, R. Q.
1993-01-01
A full-wave spectral domain analysis has been used to obtain input-impedance results for a probe-fed rectangular-patch antenna, modeling the source as a magnetic-current frill. Multiple modes are used in the probe surface current to account for axial and azimuthal variations. It is established that maximum resistance is dependent on the substrate loss tangent. The axial variation of the probe current must be taken into account for substrate thicknesses greater than about 0.02 wavelengths.
Review Of E-Beam Electrical Test Techniques
NASA Astrophysics Data System (ADS)
Hohn, Fritz J.
1987-09-01
Electron beams as a viable technique for contactless testing of electrical functions and electrical integrity of different active devices in VLSI-chips has been demonstrated over the past years. This method of testing electronic networks, most widely used in the laboratory environment, is based on an electron probe which is deflected from point to point in the network. A current of secondary electrons emitted in response to the impingement of the electron probe is converted to a signal indicating the presence of a voltage or varying potential at the different points. Voltage contrast, electron beam induced current, dual potential approach, stroboscopic techniques and other methods have been developed and are used to detect different functional failures in devices. Besides the VLSI application, the contactless testing of three dimensional conductor networks of a 10cm x 10cm x .8cm multilayer ceramic module poses a different and new application for the electron beam test technique. A dual potential electron beam test system allows to generate electron beam induced voltage contrast. The same system at a different potential is used to detect this voltage contrast over the large area without moving the substrate and thus test for the electrical integrity of the networks. Less attention in most of the applications has been paid to the electron optical environment, mostly SEM's were upgraded or converted to do the job of a "voltage contrast" machine. This by no means will satisfy all requirements and more thoughts have to be given to aspects such as: low voltage electron guns: thermal emitter, Schottky emitter, field emitter, low voltage electron optics, two lens systems, different means of detection, signal processing - storage and others. This paper will review available E-beam test techniques, specific applications and some critical components.
Grain Boundary Resistivity of Yttria-Stabilized Zirconia at 1400°C
Wang, J.; Du, A.; Yang, Di; ...
2013-01-01
Tmore » he grain size dependence of the bulk resistivity of 3 mol% yttria-stabilized zirconia at 1400°C was determined from the effect of a dc electric field E a = 18.1 V/cm on grain growth and the corresponding electric current during isothermal annealing tests. Employing the brick layer model, the present annealing test results were in accordance with extrapolations of the values obtained at lower temperature employing impedance spectroscopy and 4-point-probe dc. he combined values give that the magnitude of the grain boundary resistivity ρ b = 133 ohm-cm. he electric field across the grain boundary width was 28–43 times the applied field for the grain size and current ranges in the present annealing test.« less
Lee, Ki Ha; Becker, Alex; Faybishenko, Boris A.; Solbau, Ray D.
2003-10-21
A miniaturized electrical resistivity (ER) probe based on a known current-voltage (I-V) electrode structure, the Wenner array, is designed for local (point) measurement. A pair of voltage measuring electrodes are positioned between a pair of current carrying electrodes. The electrodes are typically about 1 cm long, separated by 1 cm, so the probe is only about 1 inch long. The electrodes are mounted to a rigid tube with electrical wires in the tube and a sand bag may be placed around the electrodes to protect the electrodes. The probes can be positioned in a borehole or on the surface. The electrodes make contact with the surrounding medium. In a dual mode system, individual probes of a plurality of spaced probes can be used to measure local resistance, i.e. point measurements, but the system can select different probes to make interval measurements between probes and between boreholes.
Eddy-Current Inspection Of Tab Seals On Beverage Cans
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph
1994-01-01
Eddy-current inspection system monitors tab seals on beverage cans. Device inspects all cans at usual production rate of 1,500 to 2,000 cans per minute. Automated inspection of all units replaces visual inspection by microscope aided by mass spectrometry. System detects defects in real time. Sealed cans on conveyor pass near one of two coils in differential eddy-current probe. Other coil in differential eddy-current probe positioned near stationary reference can on which tab seal is known to be of acceptable quality. Signal of certain magnitude at output of probe indicates defective can, automatically ejected from conveyor.
Eddy Current Testing for Detecting Small Defects in Thin Films
NASA Astrophysics Data System (ADS)
Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor
2007-03-01
Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.
Oligonucleotide probes functionalization of nanogap electrodes.
Zaffino, Rosa Letizia; Mir, Mònica; Samitier, Josep
2017-11-01
Nanogap electrodes have attracted a lot of consideration as promising platform for molecular electronic and biomolecules detection. This is mainly for their higher aspect ratio, and because their electrical properties are easily accessed by current-voltage measurements. Nevertheless, application of standard current-voltages measurements used to characterize nanogap response, and/or to modify specific nanogap electrodes properties, represents an issue. Since the strength of electrical fields in nanoscaled devices can reach high values, even at low voltages. Here, we analyzed the effects induced by different methods of surface modification of nanogap electrodes, in test-voltage application, employed for the electrical detection of a desoxyribonucleic acid (DNA) target. Nanogap electrodes were functionalized with two antisymmetric oligo-probes designed to have 20 terminal bases complementary to the edges of the target, which after hybridization bridges the nanogap, closing the electrical circuit. Two methods of functionalization were studied for this purpose; a random self-assembling of a mixture of the two oligo-probes (OPs) used in the platform, and a selective method that controls the position of each OP at selected side of nanogap electrodes. We used for this aim, the electrophoretic effect induced on negatively charged probes by the application of an external direct current voltage. The results obtained with both functionalization methods where characterized and compared in terms of electrode surface covering, calculated by using voltammetry analysis. Moreover, we contrasted the electrical detection of a DNA target in the nanogap platform either in site-selective and in randomly assembled nanogap. According to our results, a denser, although not selective surface functionalization, is advantageous for such kind of applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Deike, Susann; Deliano, Matthias; Brechmann, André
2016-10-01
One hypothesis concerning the neural underpinnings of auditory streaming states that frequency tuning of tonotopically organized neurons in primary auditory fields in combination with physiological forward suppression is necessary for the separation of representations of high-frequency A and low-frequency B tones. The extent of spatial overlap between the tonotopic activations of A and B tones is thought to underlie the perceptual organization of streaming sequences into one coherent or two separate streams. The present study attempts to interfere with these mechanisms by transcranial direct current stimulation (tDCS) and to probe behavioral outcomes reflecting the perception of ABAB streaming sequences. We hypothesized that tDCS by modulating cortical excitability causes a change in the separateness of the representations of A and B tones, which leads to a change in the proportions of one-stream and two-stream percepts. To test this, 22 subjects were presented with ambiguous ABAB sequences of three different frequency separations (∆F) and had to decide on their current percept after receiving sham, anodal, or cathodal tDCS over the left auditory cortex. We could confirm our hypothesis at the most ambiguous ∆F condition of 6 semitones. For anodal compared with sham and cathodal stimulation, we found a significant decrease in the proportion of two-stream perception and an increase in the proportion of one-stream perception. The results demonstrate the feasibility of using tDCS to probe mechanisms underlying auditory streaming through the use of various behavioral measures. Moreover, this approach allows one to probe the functions of auditory regions and their interactions with other processing stages. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Progress In Plasma Accelerator Development for Dynamic Formation of Plasma Liners
NASA Technical Reports Server (NTRS)
Thio, Y. C. Francis; Eskridge, Richard; Martin, Adam; Smith, James; Lee, Michael; Cassibry, Jason T.; Griffin, Steven; Rodgers, Stephen L. (Technical Monitor)
2002-01-01
An experimental plasma accelerator for magnetic target fusion (MTF) applications under development at the NASA Marshall Space Flight Center is described. The accelerator is a coaxial pulsed plasma thruster (Figure 1). It has been tested experimentally and plasma jet velocities of approx.50 km/sec have been obtained. The plasma jet has been photographed with 10-ns exposure times to reveal a stable and repeatable plasma structure (Figure 2). Data for velocity profile information has been obtained using light pipes and magnetic probes embedded in the gun walls to record the plasma and current transit respectively at various barrel locations. Preliminary spatially resolved spectral data and magnetic field probe data are also presented. A high speed triggering system has been developed and tested as a means of reducing the gun "jitter". This jitter is being characterized and future work for second generation "ultra-low jitter" gun development is being identified.
NASA Technical Reports Server (NTRS)
Wincheski, Buzz A.; Simpson, John W.; Koshti, Ajay
2007-01-01
A recent identification of cracking in the Space Shuttle Primary Reaction Control System (PRCS) thrusters triggered an extensive nondestructive evaluation effort to develop techniques capable of identifying such damage on installed shuttle hardware. As a part of this effort, specially designed eddy current probes inserted into the acoustic cavity were explored for the detection of such flaws and for evaluation of the remaining material between the crack tip and acoustic cavity. The technique utilizes two orthogonal eddy current probes which are scanned under stepper motor control in the acoustic cavity to identify cracks hidden with as much as 0.060 remaining wall thickness to the cavity. As crack growth rates in this area have been determined to be very slow, such an inspection provides a large safety margin for continued operation of the critical shuttle hardware. Testing has been performed on thruster components with both actual and fabricated defects. This paper will review the design and performance of the developed eddy current inspection system. Detection of flaws as a function of remaining wall thickness will be presented along with the proposed system configuration for depot level or on-vehicle inspection capabilities.
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Simpson, John; Koshti, Ajay
2006-01-01
A recent identification of stress corrosion cracking in the Space Shuttle Primary Reaction Control System (PRCS) thrusters triggered an extensive nondestructive evaluation effort to develop techniques capable of identifying such damage on installed shuttle hardware. As a part of this effort, specially designed eddy current probes inserted into the acoustic cavity were explored for the detection of such flaws and for evaluation of the remaining material between the crack tip and acoustic cavity. The technique utilizes two orthogonal eddy current probes which are scanned under stepper motor control in the acoustic cavity to identify cracks hidden with as much as 0.060 remaining wall thickness to the cavity. As crack growth rates in this area have been determined to be very slow, such an inspection provides a large safety margin for continued operation of the critical shuttle hardware. Testing has been performed on thruster components with both actual and fabricated defects. This paper will review the design and performance of the developed eddy current inspection system. Detection of flaws as a function of remaining wall thickness will be presented along with the proposed system configuration for depot level or on-vehicle inspection capabilities.
Eddy-Current Probes For Inspecting Graphite-Fiber Composites
NASA Technical Reports Server (NTRS)
Workman, Gary L.; Wang, Morgan
1992-01-01
Eddy-current probes with E-shaped and U-shaped magnetic cores developed to detect flaws in graphite-fiber/epoxy and other composites. Magnetic fields more concentrated, yielding better coupling with specimens.
Comparative analyses of plasma probe diagnostics techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Godyak, V. A.; Alexandrovich, B. M.
The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much asmore » an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.« less
Comparative analyses of plasma probe diagnostics techniques
NASA Astrophysics Data System (ADS)
Godyak, V. A.; Alexandrovich, B. M.
2015-12-01
The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.
High-resolution disruption halo current measurements using Langmuir probes in Alcator C-Mod
NASA Astrophysics Data System (ADS)
Tinguely, R. A.; Granetz, R. S.; Berg, A.; Kuang, A. Q.; Brunner, D.; LaBombard, B.
2018-01-01
Halo currents generated during disruptions on Alcator C-Mod have been measured with Langmuir ‘rail’ probes. These rail probes are embedded in a lower outboard divertor module in a closely-spaced vertical (poloidal) array. The dense array provides detailed resolution of the spatial dependence (~1 cm spacing) of the halo current distribution in the plasma scrape-off region with high time resolution (400 kHz digitization rate). As the plasma limits on the outboard divertor plate, the contact point is clearly discernible in the halo current data (as an inversion of current) and moves vertically down the divertor plate on many disruptions. These data are consistent with filament reconstructions of the plasma boundary, from which the edge safety factor of the disrupting plasma can be calculated. Additionally, the halo current ‘footprint’ on the divertor plate is obtained and related to the halo flux width. The voltage driving halo current and the effective resistance of the plasma region through which the halo current flows to reach the probes are also investigated. Estimations of the sheath resistance and halo region resistivity and temperature are given. This information could prove useful for modeling halo current dynamics.
SPM investigation of local aging effects in glassy polymers
NASA Astrophysics Data System (ADS)
Crider, Philip
2005-03-01
We investigate the cooperative and heterogeneous nature of glassy dynamics by nanometer-scale probing in a glassy polymer, Polyvinyl-Actetate (PVAc), with a Scanning Force Microscope (SFM). Using ultra-high-vacuum (UHV) Scanning Capacitive Force Microscopy techniques, nanometer-scale capacitive responses are probed. Dielectric relaxation near the glass transition is investigated, and scanning capabilities are utilized to analyze spatial response on a nanometer scale. The results of these studies may yield insight into the understanding of temperature-dependent cooperative length scales, local aging properties, and energy landscape properties of evolving dipole clusters on a mesoscopic scale. Results are used to test the validity and relevance of current models of glassy dynamics.
Mass Spectrometry for Paper-Based Immunoassays: Toward On-Demand Diagnosis.
Chen, Suming; Wan, Qiongqiong; Badu-Tawiah, Abraham K
2016-05-25
Current analytical methods, either point-of-care or centralized detection, are not able to meet recent demands of patient-friendly testing and increased reliability of results. Here, we describe a two-point separation on-demand diagnostic strategy based on a paper-based mass spectrometry immunoassay platform that adopts stable and cleavable ionic probes as mass reporter; these probes make possible sensitive, interruptible, storable, and restorable on-demand detection. In addition, a new touch paper spray method was developed for on-chip, sensitive, and cost-effective analyte detection. This concept is successfully demonstrated via (i) the detection of Plasmodium falciparum histidine-rich protein 2 antigen and (ii) multiplexed and simultaneous detection of cancer antigen 125 and carcinoembryonic antigen.
Pulsed Eddy Current Probe Design Based on Transient Circuit Analysis
NASA Astrophysics Data System (ADS)
Cadeau, Trevor J.; Krause, Thomas W.
2009-03-01
Probe design parameters affecting depth of penetration of pulsed eddy currents in multi-layer aluminum 2024-T3 were examined. Several probe designs were evaluated for their ability to detect a discontinuity at the bottom of a stack of aluminum plates. The reflection type probes, consisting of pick-up coil and encircling drive coil, were characterized based on their transient response to a square pulse excitation. Probes with longer fundamental time constants, equivalent to a lower driving frequency, generated greater depth of penetration. However, additional factors such as inductive and resistive load, and excessive coil heating were also factors that limited signal-to-noise response with increasing layer thickness.
A novel radioguided surgery technique exploiting β- decays
NASA Astrophysics Data System (ADS)
Camillocci, E. Solfaroli; Baroni, G.; Bellini, F.; Bocci, V.; Collamati, F.; Cremonesi, M.; De Lucia, E.; Ferroli, P.; Fiore, S.; Grana, C. M.; Marafini, M.; Mattei, I.; Morganti, S.; Paganelli, G.; Patera, V.; Piersanti, L.; Recchia, L.; Russomando, A.; Schiariti, M.; Sarti, A.; Sciubba, A.; Voena, C.; Faccini, R.
2014-03-01
The background induced by the high penetration power of the radiation is the main limiting factor of the current radio-guided surgery (RGS). To partially mitigate it, a RGS with β+-emitting radio-tracers has been suggested in literature. Here we propose the use of β--emitting radio-tracers and β- probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes probes less effective. We developed a β- probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1 ml can be reached within 1 s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.
A novel radioguided surgery technique exploiting β(-) decays.
Camillocci, E Solfaroli; Baroni, G; Bellini, F; Bocci, V; Collamati, F; Cremonesi, M; De Lucia, E; Ferroli, P; Fiore, S; Grana, C M; Marafini, M; Mattei, I; Morganti, S; Paganelli, G; Patera, V; Piersanti, L; Recchia, L; Russomando, A; Schiariti, M; Sarti, A; Sciubba, A; Voena, C; Faccini, R
2014-03-20
The background induced by the high penetration power of the radiation is the main limiting factor of the current radio-guided surgery (RGS). To partially mitigate it, a RGS with β(+)-emitting radio-tracers has been suggested in literature. Here we propose the use of β(-)-emitting radio-tracers and β(-) probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes probes less effective. We developed a β(-) probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1 ml can be reached within 1 s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.
A novel radioguided surgery technique exploiting β− decays
Camillocci, E. Solfaroli; Baroni, G.; Bellini, F.; Bocci, V.; Collamati, F.; Cremonesi, M.; De Lucia, E.; Ferroli, P.; Fiore, S.; Grana, C. M.; Marafini, M.; Mattei, I.; Morganti, S.; Paganelli, G.; Patera, V.; Piersanti, L.; Recchia, L.; Russomando, A.; Schiariti, M.; Sarti, A.; Sciubba, A.; Voena, C.; Faccini, R.
2014-01-01
The background induced by the high penetration power of the radiation is the main limiting factor of the current radio-guided surgery (RGS). To partially mitigate it, a RGS with β+-emitting radio-tracers has been suggested in literature. Here we propose the use of β−-emitting radio-tracers and β− probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes probes less effective. We developed a β− probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1 ml can be reached within 1 s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible. PMID:24646766
Monitoring transients in low inductance circuits
Guilford, Richard P.; Rosborough, John R.
1987-01-01
A pair of flat cable transmission lines are monitored for transient current spikes by using a probe connected to a current transformer by a pickup loop and monitoring the output of the current transformer. The approach utilizes a U-shaped pickup probe wherein the pair of flat cable transmission lines are received between the legs of the U-shaped probe. The U-shaped probe is preferably formed of a flat coil conductor adhered to one side of a flexible substrate. On the other side of the flexible substrate there is a copper foil shield. The copper foil shield is connected to one end of the flat conductor coil and connected to one leg of the pickup loop which passes through the current transformer. The other end of the flat conductor coil is connected to the other leg of the pickup loop.
Babu, Binoy; Washburn, Brian K; Ertek, Tülin Sarigül; Miller, Steven H; Riddle, Charles B; Knox, Gary W; Ochoa-Corona, Francisco M; Olson, Jennifer; Katırcıoğlu, Yakup Zekai; Paret, Mathews L
2017-09-01
Rose rosette disease, caused by Rose rosette virus (RRV; genus Emaravirus) is a major threat to the rose industry in the U.S. The only strategy currently available for disease management is early detection and eradication of the infected plants, thereby limiting its potential spread. Current RT-PCR based diagnostic methods for RRV are time consuming and are inconsistent in detecting the virus from symptomatic plants. Real-time RT-qPCR assay is highly sensitive for detection of RRV, but it is expensive and requires well-equipped laboratories. Both the RT-PCR and RT-qPCR cannot be used in a field-based testing for RRV. Hence a novel probe based, isothermal reverse transcription-recombinase polymerase amplification (RT-exoRPA) assay, using primer/probe designed based on the nucleocapsid gene of the RRV has been developed. The assay is highly specific and did not give a positive reaction to other viruses infecting roses belonging to both inclusive and exclusive genus. Dilution assays using the in vitro transcript showed that the primer/probe set is highly sensitive, with a detection limit of 1 fg/μl. In addition, a rapid technique for the extraction of viral RNA (<5min) has been standardized from RRV infected tissue sources, using PBS-T buffer (pH 7.4), which facilitates the virus adsorption onto the PCR tubes at 4°C for 2min, followed by denaturation to release the RNA. RT-exoRPA analysis of the infected plants using the primer/probe indicated that the virus could be detected from leaves, stems, petals, pollen, primary roots and secondary roots. In addition, the assay was efficiently used in the diagnosis of RRV from different rose varieties, collected from different states in the U.S. The entire process, including the extraction can be completed in 25min, with less sophisticated equipments. The developed assay can be used with high efficiency in large scale field testing for rapid detection of RRV in commercial nurseries and landscapes. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bakhtiari, S.; Wang, K.; Elmer, T. W.; Koehl, E.; Raptis, A. C.
2013-01-01
With the recent cancellation of the Yucca Mountain repository and the limited availability of wet storage utilities for spent nuclear fuel (SNF), more attention has been directed toward dry cask storage systems (DCSSs) for long-term storage of SNF. Consequently, more stringent guidelines have been issued for the aging management of dry storage facilities that necessitate monitoring of the conditions of DCSSs. Continuous health monitoring of DCSSs based on temperature variations is one viable method for assessing the integrity of the system. In the present work, a novel ultrasonic temperature probe (UTP) is being tested for long-term online temperature monitoring of DCSSs. Its performance was evaluated and compared with type N thermocouple (NTC) and resistance temperature detector (RTD) using a small-scale dry storage canister mockup. Our preliminary results demonstrate that the UTP system developed at Argonne is able to achieve better than 0.8 °C accuracy, tested at temperatures of up to 400 °C. The temperature resolution is limited only by the sampling rate of the current system. The flexibility of the probe allows conforming to complex geometries thus making the sensor particularly suited to measurement scenarios where access is limited.
NASA Astrophysics Data System (ADS)
Park, Jun-Hyub; Shin, Myung-Soo
2011-09-01
This paper describes the results of tensile tests for a beryllium-copper (BeCu) alloy thin film and the application of the results to the design of a probe. The copper alloy films were fabricated by electroplating. To obtain the tensile characteristics of the film, the dog-bone type specimen was fabricated by the etching method. The tensile tests were performed with the specimen using a test machine developed by the authors. The BeCu alloy has an elastic modulus of 119 GPa and the 0.2% offset yield and ultimate tensile strengths of 1078 MPa and 1108 MPa, respectively. The design and manufacture of a smaller probe require higher pad density and smaller pad-pitch chips. It should be effective in high-frequency testing. For the design of a new micro-probe, we investigated several design parameters that may cause problems, such as the contact force and life, using the tensile properties and the design of experiment method in conjunction with finite element analysis. The optimal dimensions of the probe were found using the response surface method. The probe with optimal dimensions was manufactured by a precision press process. It was verified that the manufactured probe satisfied the life, the contact force and the over drive through the compression tests and the life tests of the probes.
Test Sequence Priming in Recognition Memory
ERIC Educational Resources Information Center
Johns, Elizabeth E.; Mewhort, D. J. K.
2009-01-01
The authors examined priming within the test sequence in 3 recognition memory experiments. A probe primed its successor whenever both probes shared a feature with the same studied item ("interjacent priming"), indicating that the study item like the probe is central to the decision. Interjacent priming occurred even when the 2 probes did…
Investigating electrical resonance in eddy-current array probes
NASA Astrophysics Data System (ADS)
Hughes, R.; Fan, Y.; Dixon, S.
2016-02-01
The sensitivity enhancing effects of eddy-current testing at frequencies close to electrical resonance are explored. Var-ied techniques exploiting the phenomenon, dubbed near electrical resonance signal enhancement (NERSE), were experimentally investigated to evaluate its potential exploitation for other interesting applications in aerospace materials, in particular its potential for boosting the sensitivity of standard ECT measurements. Methods for setting and controlling the typically unstable resonant frequencies of such systems are discussed. This research is funded by the EPSRC, via the Research Centre for Non-Destructive Evaluation RCNDE, and Rolls-Royce plc.
George, Mark S; Aston-Jones, Gary
2010-01-01
Although the preceding chapters discuss much of the new knowledge of neurocircuitry of neuropsychiatric diseases, and an invasive approach to treatment, this chapter describes and reviews the noninvasive methods of testing circuit-based theories and treating neuropsychiatric diseases that do not involve implanting electrodes into the brain or on its surface. These techniques are transcranial magnetic stimulation, vagus nerve stimulation, and transcranial direct current stimulation. Two of these approaches have FDA approval as therapies. PMID:19693003
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Williams, Phillip; Simpson, John
2007-01-01
The use of eddy current techniques for the detection of outer diameter damage in tubing and many complex aerospace structures often requires the use of an inner diameter probe due to a lack of access to the outside of the part. In small bore structures the probe size and orientation are constrained by the inner diameter of the part, complicating the optimization of the inspection technique. Detection of flaws through a significant remaining wall thickness becomes limited not only by the standard depth of penetration, but also geometrical aspects of the probe. Recently, an orthogonal eddy current probe was developed for detection of such flaws in Space Shuttle Primary Reaction Control System (PRCS) Thrusters. In this case, the detection of deeply buried stress corrosion cracking by an inner diameter eddy current probe was sought. Probe optimization was performed based upon the limiting spatial dimensions, flaw orientation, and required detection sensitivity. Analysis of the probe/flaw interaction was performed through the use of finite and boundary element modeling techniques. Experimental data for the flaw detection capabilities, including a probability of detection study, will be presented along with the simulation data. The results of this work have led to the successful deployment of an inspection system for the detection of stress corrosion cracking in Space Shuttle Primary Reaction Control System (PRCS) Thrusters.
NASA Technical Reports Server (NTRS)
Klenzing, Jeffrey H.; Rowland, Douglas E.
2012-01-01
A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasmadensity is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future xed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.
Detection of Real Flaw using Uniform Eddy Current Multi-probe
NASA Astrophysics Data System (ADS)
Fukuoka, Katsuhiro; Hashimoto, Mitsuo
The establishment of the nondestructive inspection technology with plant structures has been stimulated by the recent occurrence of cracks in the nuclear power plant structures. In this research, a uniform eddy current multi-probe to apply to the complex structure and inspect the cracks at high-speed data acquisition was developed. Pick-up coils of the developed probe were arranged on a flexible printed circuit board. This probe was able to obtain clear signal for an EDM (electro-discharge machining) slit with 0.5 mm depth and distinguish EDM slits arranged at 2 mm intervals. It was confirmed that the SCC (stress corrosion cracking) of real flaw was able to be detected with developed uniform eddy current multi-probe by using the ferrite core for the exciting coil and considering the impedance matching of the exciting coil and the flaw detection device.
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
49 CFR 572.136 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... as measured with the test probe-mounted accelerometer must be not less than 3450 N (776 lbf) and not... tibia may contact any exterior surface. (3) Align the test probe so that throughout its stroke and at... movement at the time of initial contact between the impactor and the knee. (5) The test probe velocity at...
Eddy Current Method for Fatigue Testing
NASA Technical Reports Server (NTRS)
Simpson, John W. (Inventor); Fulton, James P. (Inventor); Wincheski, Russell A. (Inventor); Todhunter, Ronald G. (Inventor); Namkung, Min (Inventor); Nath, Shridhar C. (Inventor)
1997-01-01
Flux-focusing electromagnetic sensor using a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. A ferrous shield isolates a high-turn pick-up coil from an excitation coil. Use of the magnetic shield produces a null voltage output across the receiving coil in presence of an unflawed sample. Redistribution of the current flow in the sample caused by the presence of flaws. eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. Maximum sensor output is obtained when positioned symmetrically above the crack. By obtaining position of maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. Accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output resulting in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip enabling the search region to be clearly defined. Under low frequency operation, material thinning due to corrosion causes incomplete shielding of the pick-up coil. Low frequency output voltage of the probe is therefore a direct indicator of thickness of the test sample. Fatigue testing a conductive material is accomplished by applying load to the material, applying current to the sensor, scanning the material with the sensor, monitoring the sensor output signal, adjusting material load based on the sensor output signal of the sensor, and adjusting position of the sensor based on its output signal.
Probe Array Correction With Strong Target Interactions
2012-08-01
exciting each probe array feed with a unit voltage source and computing the short circuit currents, ii, i = 1 , 2 , . . . , 5, at each probe array feed...that only one probe array element has unit terminal currents. In this case I2 = Îi = IN − Y NV 2 = IN − Y N [ Y is + Y N ]− 1 IN = (I − Y N [ Y is + Y...YOUR FORM TO THE ABOVE ADDRESS. 1 . REPORT DATE (DD-MM-YY) 2 . REPORT TYPE 3. DATES COVERED (From - To) August 2012 Interim 01 May 2011 – 31 May
Apparatus for measuring the local void fraction in a flowing liquid containing a gas
Dunn, P.F.
1979-07-17
The local void fraction in liquid containing a gas is measured by placing an impedance-variation probe in the liquid, applying a controlled voltage or current to the probe, and measuring the probe current or voltage. A circuit for applying the one electrical parameter and measuring the other includes a feedback amplifier that minimizes the effect of probe capacitance and a digitizer to provide a clean signal. Time integration of the signal provides a measure of the void fraction, and an oscilloscope display also shows bubble size and distribution.
Apparatus for measuring the local void fraction in a flowing liquid containing a gas
Dunn, Patrick F.
1981-01-01
The local void fraction in liquid containing a gas is measured by placing an impedance-variation probe in the liquid, applying a controlled voltage or current to the probe, and measuring the probe current or voltage. A circuit for applying the one electrical parameter and measuring the other includes a feedback amplifier that minimizes the effect of probe capacitance and a digitizer to provide a clean signal. Time integration of the signal provides a measure of the void fraction, and an oscilloscope display also shows bubble size and distribution.
Prevosto, L; Kelly, H; Mancinelli, B
2013-12-01
This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitz, Roger William; Oh, Yunje
A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably receivedmore » and clamped within the socket.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Ikjin; Chung, ChinWook; Youn Moon, Se
2013-08-15
In plasma diagnostics with a single Langmuir probe, the electron temperature T{sub e} is usually obtained from the slope of the logarithm of the electron current or from the electron energy probability functions of current (I)-voltage (V) curve. Recently, Chen [F. F. Chen, Phys. Plasmas 8, 3029 (2001)] suggested a derivative analysis method to obtain T{sub e} by the ratio between the probe current and the derivative of the probe current at a plasma potential where the ion current becomes zero. Based on this method, electron temperatures and electron densities were measured and compared with those from the electron energymore » distribution function (EEDF) measurement in Maxwellian and bi-Maxwellian electron distribution conditions. In a bi-Maxwellian electron distribution, we found the electron temperature T{sub e} obtained from the method is always lower than the effective temperatures T{sub eff} derived from EEDFs. The theoretical analysis for this is presented.« less
Protein recognition by a pattern-generating fluorescent molecular probe.
Pode, Zohar; Peri-Naor, Ronny; Georgeson, Joseph M; Ilani, Tal; Kiss, Vladimir; Unger, Tamar; Markus, Barak; Barr, Haim M; Motiei, Leila; Margulies, David
2017-12-01
Fluorescent molecular probes have become valuable tools in protein research; however, the current methods for using these probes are less suitable for analysing specific populations of proteins in their native environment. In this study, we address this gap by developing a unimolecular fluorescent probe that combines the properties of small-molecule-based probes and cross-reactive sensor arrays (the so-called chemical 'noses/tongues'). On the one hand, the probe can detect different proteins by generating unique identification (ID) patterns, akin to cross-reactive arrays. On the other hand, its unimolecular scaffold and selective binding enable this ID-generating probe to identify combinations of specific protein families within complex mixtures and to discriminate among isoforms in living cells, where macroscopic arrays cannot access. The ability to recycle the molecular device and use it to track several binding interactions simultaneously further demonstrates how this approach could expand the fluorescent toolbox currently used to detect and image proteins.
Protein recognition by a pattern-generating fluorescent molecular probe
NASA Astrophysics Data System (ADS)
Pode, Zohar; Peri-Naor, Ronny; Georgeson, Joseph M.; Ilani, Tal; Kiss, Vladimir; Unger, Tamar; Markus, Barak; Barr, Haim M.; Motiei, Leila; Margulies, David
2017-12-01
Fluorescent molecular probes have become valuable tools in protein research; however, the current methods for using these probes are less suitable for analysing specific populations of proteins in their native environment. In this study, we address this gap by developing a unimolecular fluorescent probe that combines the properties of small-molecule-based probes and cross-reactive sensor arrays (the so-called chemical 'noses/tongues'). On the one hand, the probe can detect different proteins by generating unique identification (ID) patterns, akin to cross-reactive arrays. On the other hand, its unimolecular scaffold and selective binding enable this ID-generating probe to identify combinations of specific protein families within complex mixtures and to discriminate among isoforms in living cells, where macroscopic arrays cannot access. The ability to recycle the molecular device and use it to track several binding interactions simultaneously further demonstrates how this approach could expand the fluorescent toolbox currently used to detect and image proteins.
NASA Astrophysics Data System (ADS)
Yoo, Jongsoo; Jara-Almonte, J.; Majeski, S.; Frank, S.; Ji, H.; Yamada, M.
2016-10-01
FLARE (Facility for Laboratory Reconnection Experiments) will be operated as a flexible user facility, and so a complete set of research diagnostics is under development, including magnetic probe arrays, Langmuir probes, Mach probes, spectroscopic probes, and a laser interferometer. In order to accommodate the various requirements of users, large-scale (1 m), variable resolution (0.5-4 cm) magnetic probes have been designed, and are currently being prototyped. Moreover, a fully fiber-coupled laser interferometer has been designed to measure the line-integrated electron density. This fiber-coupled interferometer system will reduce the complexity of alignment processes and minimize maintenance of the system. Finally, improvements to the electrostatic probes and spectroscopic probes currently used in the Magnetic Reconnection Experiment (MRX) are discussed. The specifications of other subsystems, such as integrators and digitizers, are also presented. This work is supported by DoE Contract No. DE-AC0209CH11466.
Design and Flight Evaluation of a New Force-Based Flow Angle Probe
NASA Technical Reports Server (NTRS)
Corda, Stephen; Vachon, Michael Jacob
2006-01-01
A novel force-based flow angle probe was designed and flight tested on the NASA F-15B Research Testbed aircraft at NASA Dryden Flight Research Center. The prototype flow angle probe is a small, aerodynamic fin that has no moving parts. Forces on the prototype flow angle probe are measured with strain gages and correlated with the local flow angle. The flow angle probe may provide greater simplicity, greater robustness, and better access to flow measurements in confined areas relative to conventional moving vane-type flow angle probes. Flight test data were obtained at subsonic, transonic, and supersonic Mach numbers to a maximum of Mach 1.70. Flight conditions included takeoff, landing, straight and level flight, flight at higher aircraft angles of attack, and flight at elevated g-loadings. Flight test maneuvers included angle-of-attack and angle-of-sideslip sweeps. The flow angle probe-derived flow angles are compared with those obtained with a conventional moving vane probe. The flight tests validated the feasibility of a force-based flow angle measurement system.
Eddy Current Probe for Surface and Sub-Surface Inspection
NASA Technical Reports Server (NTRS)
Wincheski, Russell A. (Inventor); Simpson, John W. (Inventor)
2014-01-01
An eddy current probe includes an excitation coil for coupling to a low-frequency alternating current (AC) source. A magneto-resistive sensor is centrally disposed within and at one end of the excitation coil to thereby define a sensing end of the probe. A tubular flux-focusing lens is disposed between the excitation coil and the magneto-resistive sensor. An excitation wire is spaced apart from the magneto-resistive sensor in a plane that is perpendicular to the sensor's axis of sensitivity and such that, when the sensing end of the eddy current probe is positioned adjacent to the surface of a structure, the excitation wire is disposed between the magneto-resistive sensor and the surface of the structure. The excitation wire is coupled to a high-frequency AC source. The excitation coil and flux-focusing lens can be omitted when only surface inspection is required.
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
49 CFR 572.176 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...
Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Shastry, Rohit
2012-01-01
There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.
Current Density Measurements of an Annular-Geometry Ion Engine
NASA Technical Reports Server (NTRS)
Shastry, Rohit; Patterson, Michael J.; Herman, Daniel A.; Foster, John E.
2012-01-01
The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.
Current Density Measurements of an Annular-Geometry Ion Engine
NASA Technical Reports Server (NTRS)
Shastry, Rohit; Patterson, Michael J.; Herman, Daniel A.; Foster, John E.
2012-01-01
The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential non-uniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to +/-10% of the average current density in the discharge and +/-5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 - 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.
Preliminary test results of electrical charged particle generator for application to fog dispersal
NASA Technical Reports Server (NTRS)
Frost, W.
1982-01-01
A charged particle generator for use in fog dispersal applications was built and preliminary tests were carried out. The parameter used as a measure of performance was the current measured with a needle probe positioned in the charged jet connected to ground through an ammeter. The needle was movable and allowed the current profile throughout the jet to be determined. The measured current is referred to as the current output. The major independent parameters were liquid water injection rate, plenum pressure, and corona voltage. Optimum current output was achieved at the approximate pressure of 30 psig, corona voltage of 5600 volts, and liquid water injection rate of 6 cc/min. The results of the test with the prototype charged particle generator clearly demonstrate that a current on the order of 20 microamperes can be routinely achieved with the system. This measurement of current does not necessarily represent the total issuing from the nozzle current which is expected to be larger. From these results, confidence was established that a charged particle generator which will operate continuously and consistently can be designed, constructed, and operated. Further work is required, however, to better understand the physical mechanisms involved and to optimize the system for fog dispersal application.
ERIC Educational Resources Information Center
Yi, Yeon-Sook
2017-01-01
The present study examines the relative importance of attributes within and across items by applying four cognitive diagnostic assessment models. The current study utilizes the function of the models that can indicate inter-attribute relationships that reflect the response behaviors of examinees to analyze scored test-taker responses to four forms…
Final Report: Continuation Study: A Systems Approach to Understanding Post-Traumatic Stress Disorder
2017-01-31
Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Post Traumatic Stress Disorder, HPA-Circadian-metabolic pathway, methylation...17150 remaining probes were located in coding regions. Linear additive models were used to test the interactions among the quantitative loci and...SECURITY CLASSIFICATION OF: Post -Traumatic Stress Disorder (PTSD) is a complex anxiety disorder affecting many combat-exposed soldiers. Current
Wright Research and Development Center Test Facilities Handbook
1990-01-01
Variable Temperature (2-400K) and Field (0-5 Tesla) Squid Susceptometer Variable Temperature (10-80K) and Field (0-10 Tesla) Transport Current...determine products of combustion using extraction type probes INSTRUMENTATION: Mini computer/data acquisiton system Networking provides access to larger...data recorder, Masscomp MC-500 computer with acquisition digitizer, laser and ink -jet printers,lo-pass filters, pulse code modulation AVAILABILITY
Levine, R L; Fromm, R E; Mojtahedzadeh, M; Baghaie, A A; Opekun, A R
1994-06-01
To compare the accuracy of litmus paper-determined gastric pH to a nasogastric graphite antimony pH probe. A prospective clinical trial of gastric pH determination in patients enrolled in a study of histamine-2-receptor (H2) antagonists. The medical intensive care unit (ICU) of a 450-bed county hospital. Critically ill ICU patients requiring stress ulcer prophylaxis. Using a crossover design, the patients were randomized to initially receive an H2 antagonist by continuous infusion or intravenous bolus, and subsequently were crossed over to the other limb of the study. Gastric pH was determined using pH-sensitive litmus paper at the initiation of each limb of the study and at 1, 2, 4, and 8 hrs after the initiation of H2 receptor antagonist therapy. In addition, gastric pH was continuously determined over the same time period utilizing a graphite antimony pH probe. Gastric pH measurements determined with litmus paper and intragastric pH probes demonstrated an excellent correlation (r2 = .93, p < .001). McNemar's test of correlated proportions could not demonstrate a significant difference between the two monitoring methods (chi-square = 0.5, p > .47), and the kappa statistic (0.95, p < .001) demonstrated excellent concordance. Bias measurement was 0.01 (95% confidence interval = -0.155 to 0.176). Measurement of intragastric pH, using pH-sensitive litmus paper, is both sensitive and specific when utilizing a graphite antimony nasogastric pH probe as a reference standard. Litmus paper-determined gastric pH testing is both easy to perform and inexpensive. Therefore, based on the current data, we believe this technique (i.e., litmus paper determined gastric pH testing) to be the method of choice for determination of intragastric pH in patients at risk for stress gastric ulcers in the medical ICU.
Study of borehole probing methods to improve the ground characterization
NASA Astrophysics Data System (ADS)
Naeimipour, Ali
Collecting geological information allows for optimizing ground control measures in underground structures. This includes understanding of the joints and discontinuities and rock strength to develop rock mass classifications. An ideal approach to collect such information is through correlating the drilling data from the roofbolters to assess rock strength and void location and properties. The current instrumented roofbolters are capable of providing some information on these properties but not fully developed for accurate ground characterization. To enhance existing systems additional instrumentation and testing was conducted in laboratory and field conditions. However, to define the geology along the boreholes, the use of probing was deemed to be most efficient approach for locating joints and structures in the ground and evaluation of rock strength. Therefore, this research focuses on selection and evaluation of proper borehole probes that can offer a reliable assessment of rock mass structure and rock strength. In particular, attention was paid to borehole televiewer to characterize rock mass structures and joints and development of mechanical rock scratcher for determination of rock strength. Rock bolt boreholes are commonly drilled in the ribs and the roof of underground environments. They are often small (about 1.5 inches) and short (mostly 2-3 meter). Most of them are oriented upward and thus, mostly dry or perhaps wet but not filled with water. No suitable system is available for probing in such conditions to identify the voids/joints and specifically to measure rock strength for evaluation of rock mass and related optimization of ground support design. A preliminary scan of available borehole probes proved that the best options for evaluation of rock structure is through analysis of borehole images, captured by optical televiewers. Laboratory and field trials with showed that these systems can be used to facilitate measurement of the location, frequency and partially condition of discontinuities. Two of the more promising tools have been tested during this project, which are QL40OBI Optical TV and Slim Borehole Scanner (SBS) manufacture by ALT-Mount Sopris and DMT, respectively. The field experiment with QL40OBI showed that the images generated for downward and sub-horizontal boreholes are of good quality and can be used to evaluate the joint conditions. However, this device is not suitable for use inside the upward drillholes. The Slim Borehole Scanner (SBS) manufactured by DMT in Germany has the required features for borescoping the roofbolt holes. This includes the ease of operation and suitable geometry along with an unwrapped 360-degree picture of the borehole wall. This instrument was concluded to be the best option yet for obtaining images from boreholes with any arbitrary orientation. In addition, a new tool, called Rock Strength Borehole Probe (RSBP), was developed for estimation of the rock strength through scratching the rock surface in the borehole. This device is designed to be a light, flexible, quick, non-disruptive, and cost effective alternative to estimate the rock strength inside the boreholes in underground mines and tunnels. An extensive number of laboratory tests under variable conditions were conducted to develop equations to estimate the Uniaxial Compressive Strength (UCS) and Brazilian Tensile Strength (BTS) of the rock from measured cutting forces. In these experiments, 27 different rock types were tested by full scale scratch tests, including the cutting tests by a miniature disc. The results show a good correlation between the normal force and the compressive strength of sedimentary/metamorphic rock if the depth of scratch is known. No significant correlation was observed for igneous rocks, due to the impacts of grain size. Current studies show promising results for using RSBP. The laboratory and field tests proved the functionality of this tool. This probe is capable of entering boreholes of 45 mm (1¾ in) diameter in any direction and create a groove on the walls and by measurement of the location and cutting forces, estimate rock strength. Additional testing in various underground operations are needed for fine tune the operational features of this probe and make it more accurate. The combination of rock strength and joint conditions will allow for development of rock mass classification that could be used for 3D imaging of the ground conditions around an underground opening as well as hazard maps for the roof.
Development of a low-cost temperature data monitoring. An upgrade for hot box apparatus
NASA Astrophysics Data System (ADS)
de Rubeis, T.; Nardi, I.; Muttillo, M.
2017-11-01
The monitoring phase has gained a fundamental role in the energy efficiency evaluation of a system. Number and typology of the probes depend on the physical quantity to be monitored, and on the size and complexity of the system. Moreover, a measurement equipment should be designed to allow the employment of probes different for number and measured physical quantities. For this reason, a scalable equipment represents a good way for easily carrying out a system monitoring. Proprietary software and high costs characterize instruments of current use, thus limiting the possibilities to realize customized monitoring. In this paper, a temperature measuring instrument, conceived, designed, and realized for real time applications, is presented. The proposed system is based on digital thermometers and on open-source code. A remarkable feature of the instrument is the possibility of acquiring data from a high and variable number of probes (order of hundred), assuring flexibility of the software, since it can be programmed, and low-cost of the hardware components. The contemporary use of multiple temperature probes suggested to apply this instrument for a hot box apparatus, although the software can be set for recording different physical quantities. A hot box compliant with standard EN ISO 8990 should be equipped with several temperature probes to investigate heat exchanges of a specimen wall and thermal field of the chambers. In this work, preliminary tests have been carried out focusing only on the evaluation of the prototypal system’s performance. The tests were realized by comparing different sensors, such as thermocouples and resistance thermometers, traditionally employed in hot box experiments. A preliminary test was realized imposing a dynamic condition with a thermoelectric Peltier cell. Data obtained by digital thermometers DS18B20, compared with the ones of Pt100 probes, show a good correlation. Based on these encouraging results, a further test was carried out in hot box, comparing the data measured by digital thermometers, Pt100 and T-type thermocouples. In this case also, the analyses show a good correlation between either digital thermometers and analog sensors. From these results, it is reasonable to foresee that this measuring instrument could help those willing to realize or refurbish a hot box apparatus, and those who want to undertake temperature monitoring.
Miniature and Molecularly Specific Optical Screening Technologies for Breast Cancer
2008-10-01
commercially available dual-channel transimpedance amplifier circuit boards (Boston Electronics, TWAMP). Preliminary results with the imaging probe...connected to a current amplifier via a coaxial cable for diffuse reflectance measurements. This new probe is named P4-3 and schematics of the system and...probe. With the single pixel device a single-channel current amplifier (Terahertz Technologies, PDA-750) could easily read and collect the photocurrent
The electrical performance of Ag Zn batteries for the Venus multi-probe mission
NASA Technical Reports Server (NTRS)
Palandati, C.
1975-01-01
An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.
Thermal Analysis of Small Re-Entry Probe
NASA Technical Reports Server (NTRS)
Agrawal, Parul; Prabhu, Dinesh K.; Chen, Y. K.
2012-01-01
The Small Probe Reentry Investigation for TPS Engineering (SPRITE) concept was developed at NASA Ames Research Center to facilitate arc-jet testing of a fully instrumented prototype probe at flight scale. Besides demonstrating the feasibility of testing a flight-scale model and the capability of an on-board data acquisition system, another objective for this project was to investigate the capability of simulation tools to predict thermal environments of the probe/test article and its interior. This paper focuses on finite-element thermal analyses of the SPRITE probe during the arcjet tests. Several iterations were performed during the early design phase to provide critical design parameters and guidelines for testing. The thermal effects of ablation and pyrolysis were incorporated into the final higher-fidelity modeling approach by coupling the finite-element analyses with a two-dimensional thermal protection materials response code. Model predictions show good agreement with thermocouple data obtained during the arcjet test.
Nonequilibrium dynamics of probe filaments in actin-myosin networks
NASA Astrophysics Data System (ADS)
Gladrow, J.; Broedersz, C. P.; Schmidt, C. F.
2017-08-01
Active dynamic processes of cells are largely driven by the cytoskeleton, a complex and adaptable semiflexible polymer network, motorized by mechanoenzymes. Small dimensions, confined geometries, and hierarchical structures make it challenging to probe dynamics and mechanical response of such networks. Embedded semiflexible probe polymers can serve as nonperturbing multiscale probes to detect force distributions in active polymer networks. We show here that motor-induced forces transmitted to the probe polymers are reflected in nonequilibrium bending dynamics, which we analyze in terms of spatial eigenmodes of an elastic beam under steady-state conditions. We demonstrate how these active forces induce correlations among the mode amplitudes, which furthermore break time-reversal symmetry. This leads to a breaking of detailed balance in this mode space. We derive analytical predictions for the magnitude of resulting probability currents in mode space in the white-noise limit of motor activity. We relate the structure of these currents to the spatial profile of motor-induced forces along the probe polymers and provide a general relation for observable currents on two-dimensional hyperplanes.
Restrepo-Ortiz, C X; Merbt, S N; Barrero-Canossa, J; Fuchs, B M; Casamayor, E O
2018-04-28
The Thaumarchaeota SAGMCG-1 group and, in particular, members of the genus Nitrosotalea have high occurrence in acidic soils, the rhizosphere, groundwater and oligotrophic lakes, and play a potential role in nitrogen cycling. In this study, the specific oligonucleotide fluorescence in situ hybridization probe SAG357 was designed for this Thaumarchaeota group based on the available 16S rRNA gene sequences in databases, and included the ammonia-oxidizing species Nitrosotalea devanaterra. Cell permeabilization for catalyzed reporter deposition fluorescence in situ detection and the hybridization conditions were optimized on enrichment cultures of the target species N. devanaterra, as well as the non-target ammonia-oxidizing archaeon Nitrosopumilus maritimus. Probe specificity was improved with a competitor oligonucleotide, and fluorescence intensity and cell visualization were enhanced by the design and application of two adjacent helpers. Probe performance was tested in soil samples along a pH gradient, and counting results matched the expected in situ distributions. Probe SAG357 and the CARD-FISH protocol developed in the present study will help to improve the current understanding of the ecology and physiology of N. devanaterra and its relatives in natural environments. Copyright © 2018 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Klammler, Harald; Layton, Leif; Nemer, Bassel; Hatfield, Kirk; Mohseni, Ana
2017-06-01
Hydraulic conductivity and its anisotropy are fundamental aquifer properties for groundwater flow and transport modeling. Current in-well or direct-push field measurement techniques allow for relatively quick determination of general conductivity profiles with depth. However, capabilities for identifying local scale conductivities in the horizontal and vertical directions are very limited. Here, we develop the theoretical basis for estimating horizontal and vertical conductivities from different types of steady-state single-well/probe injection tests under saturated conditions and in the absence of a well skin. We explore existing solutions and a recent semi-analytical solution approach to the flow problem under the assumption that the aquifer is locally homogeneous. The methods are based on the collection of an additional piece of information in the form of a second injection (or recirculation) test at a same location, or in the form of an additional head or flow observation along the well/probe. Results are represented in dimensionless charts for partial validation against approximate solutions and for practical application to test interpretation. The charts further allow for optimization of a test configuration to maximize sensitivity to anisotropy ratio. The two methods most sensitive to anisotropy are found to be (1) subsequent injection from a lateral screen and from the bottom of an otherwise cased borehole, and (2) single injection from a lateral screen with an additional head observation along the casing. Results may also be relevant for attributing consistent divergences in conductivity measurements from different testing methods applied at a same site or location to the potential effects of anisotropy. Some practical aspects are discussed and references are made to existing methods, which appear easily compatible with the proposed procedures.
Interpretation of the lime column penetration test
NASA Astrophysics Data System (ADS)
Liyanapathirana, D. S.; Kelly, R. B.
2010-06-01
Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.
Eddy Current Testing and Sizing of Deep Cracks in a Thick Structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, H.; Endo, H.; Uchimoto, T.
2004-02-26
Due to the skin effect of eddy current testing, target of ECT restricts to thin structure such as steam generator tubes with 1.27mm thickness. Detecting and sizing of a deep crack in a thick structure remains a problem. In this paper, an ECT probe is presented to solve this problem with the help of numerical analysis. The parameters such as frequency, coil size etc. are discussed. The inverse problem of crack sizing is solved by applying a fast simulator of ECT based on an edge based finite element method and steepest descent method, and reconstructed results of 5, 10 andmore » 15mm depth cracks from experimental signals are shown.« less
Long, Ju
2016-05-01
In China, -(SEA), -α(3.7) and -α(4.2) are common deletional α-thalassemia alleles. Gap-PCR is the currently used detection method for these alleles, whose disadvantages include time-consuming procedure and increased potential for PCR product contamination. Therefore, this detection method needs to be improved. Based on identical-primer homologous fragments, a qPCR system was developed for deletional α-thalassemia genotyping, which was composed of a group of quantitatively-related primers and their corresponding probes plus two groups of qualitatively-related primers and their corresponding probes. In order to verify the accuracy of the qPCR system, known genotype samples and random samples are employed. The standard curve result demonstrated that designed primers and probes all yielded good amplification efficiency. In the tests of known genotype samples and random samples, sample detection results were consistent with verification results. In detecting αα, -(SEA), -α(3.7) and -α(4.2) alleles, deletional α-thalassemia alleles are accurately detected by this method. In addition, this method is provided with a wider detection range, greater speed and reduced PCR product contamination risk when compared with current common gap-PCR detection reagents. Copyright © 2016 Elsevier B.V. All rights reserved.
Advanced electric-field scanning probe lithography on molecular resist using active cantilever
NASA Astrophysics Data System (ADS)
Kaestner, Marcus; Aydogan, Cemal; Ivanov, Tzvetan; Ahmad, Ahmad; Angelov, Tihomir; Reum, Alexander; Ishchuk, Valentyn; Krivoshapkina, Yana; Hofer, Manuel; Lenk, Steve; Atanasov, Ivaylo; Holz, Mathias; Rangelow, Ivo W.
2015-07-01
The routine "on demand" fabrication of features smaller than 10 nm opens up new possibilities for the realization of many devices. Driven by the thermally actuated piezoresistive cantilever technology, we have developed a prototype of a scanning probe lithography (SPL) platform which is able to image, inspect, align, and pattern features down to the single digit nanoregime. Here, we present examples of practical applications of the previously published electric-field based current-controlled scanning probe lithography. In particular, individual patterning tests are carried out on calixarene by using our developed table-top SPL system. We have demonstrated the application of a step-and-repeat SPL method including optical as well as atomic force microscopy-based navigation and alignment. The closed-loop lithography scheme was applied to sequentially write positive and negative tone features. Due to the integrated unique combination of read-write cycling, each single feature is aligned separately with the highest precision and inspected after patterning. This routine was applied to create a pattern step by step. Finally, we have demonstrated the patterning over larger areas, over existing topography, and the practical applicability of the SPL processes for lithography down to 13-nm pitch patterns. To enhance the throughput capability variable beam diameter electric field, current-controlled SPL is briefly discussed.
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2012 CFR
2012-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... (3) Align the test probe specified in § 572.77(a) with the longitudinal center line of the femur force gauge, so that at impact, the probe's longitudinal center line coincides with the sensor's longitudinal center line within ±2 degrees. (4) Impact the knee with the test probe moving horizontally and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
Code of Federal Regulations, 2013 CFR
2013-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2011 CFR
2011-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
Code of Federal Regulations, 2010 CFR
2010-10-01
... in paragraph (d)(7) of this section. (c) When impacted by a test probe conforming to § 572.11(a) at... forces measured by the test probe of not more than 1450 pounds and 2250 pounds, respectively, and shall... forward parallel to the midsagittal plane. (2) Place the longitudinal center line of the test probe so...
Code of Federal Regulations, 2014 CFR
2014-10-01
... SA 103C 002, sheet 8. (b) When the head is impacted by a test probe specified in § 572.21(a)(1) at 7... supports the limbs' weight when the limbs are extended horizontally forward. (2) Adjust the test probe so... the forehead immediately adjacent to the projected longitudinal centerline of the test probe is...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
NASA Astrophysics Data System (ADS)
Alves, C. S.; Leite, A. C. O.; Martins, C. J. A. P.; Silva, T. A.; Berge, S. A.; Silva, B. S. A.
2018-01-01
There is a growing interest in astrophysical tests of the stability of dimensionless fundamental couplings, such as the fine-structure constant α , as an optimal probe of new physics. The imminent arrival of the ESPRESSO spectrograph will soon enable significant gains in the precision and accuracy of these tests and widen the range of theoretical models that can be tightly constrained. Here we illustrate this by studying proposed extensions of the Bekenstein-type models for the evolution of α that allow different couplings of the scalar field to both dark matter and dark energy. We use a combination of current astrophysical and local laboratory data (from tests with atomic clocks) to show that these couplings are constrained to parts per million level, with the constraints being dominated by the atomic clocks. We also quantify the expected improvements from ESPRESSO and other future spectrographs, and briefly discuss possible observational strategies, showing that these facilities can improve current constraints by more than an order of magnitude.
In vitro assessment of fragmentation and repulsion of handheld lithotripsie devices
NASA Astrophysics Data System (ADS)
Sroka, Ronald; Pongratz, Thomas; Crameri, Giovanni; Haseke, Nicolas; Bader, Markus; Khoder, Wael
2013-03-01
Introduction: Different laser-systems are currently used for stone fragmentation in the upper urinary tract. The aim of our study was to evaluate probe velocity and displacement, retropulsion and fragmentation characteristics two novel devices the electromechanically driven EMS LithoBreaker® (EMS Medical), and of the CO2 cartridge driven LMA StoneBreaker® (Cook Urological) in vitro test models.Testing of the LithoBreaker® included additionally two different cushion guides (harder, softer) to assess the effect of the damper properties on the impulse characteristics. Patients and methods: Maximum probe velocities and displacements were measured using high-speed photography at a resolution of 100.000 frames per second. Repulsion testing was conducted through a 7.5 Fr ureteroscope in an underwater set-up. The probes were projected against a non-frangible led mass placed in a 15 Fr horizontally mounted silicone tube as an in-vitro model of the ureter. Repulsion was determined by measuring the distance the lead mass (0.98g) was displaced. Fragmentation efficiency was assessed by measuring the number of single shots required to break Bego Stone phantoms hard (15:3) and soft (15:6) with an average size of 7.5 mm x 5.5 mm placed on a metal mesh (edge length 3.15mm) into < 3 mm fragments. Mean and standard deviation were computed for all groups and statistical analysis was performed (student's t-test). Results: The StoneBreaker® yielded the highest velocity of 22.0 +/- 1.9 m/sec. followed by the LithoBreaker® assembled with the hard cushion guide of 14.2 +/- 0.5 m/sec and the soft probe guide of 11.5 +/-0.5 m/sec. accordingly. The maximum probe displacement for the StoneBreaker® was 1.04 mm and for the LithoBreaker® 0.9 mm and 1.1 mm (hard versus soft cushion guide). Repulsion produced using the 1mm probes showed no statistical differences between the devices. Using the 2mm probes, the hardness of the damper used significantly changed the repulsion behaviour of the LithoBreaker®. Using the 1mm probe, the amount of single shots for fragmentation of soft Bego Stones was significantly higher for the LithoBreaker® with soft cushion guide: mean 31.5 +/- 11.31 and hard cushion guide: mean 21.5 +/- 5.29 compared to the StoneBreaker®: mean 11.2 +/- 2.65. Fragmentation efficiency for the hard Bego Stones showed similar statistically significant results. Conclusion: The electromechanic LithoBreaker® and the pneumatic Stonebreaker® were shown to be effective in cracking stone phantoms with relatively low number of pulses. Fragmentation characteristics improved substantially with the higher hardness of the cushion support higher velocity equals higher fragmentation performance of the LithoBreaker®. Repulsion produced were at comparable levels. More testing is required to more detailed information on impulse frequency and capacity for stone clearance time to be used in clinical practice.
Fabrication of Cantilever-Bump Type Si Probe Card
NASA Astrophysics Data System (ADS)
Park, Jeong-Yong; Lee, Dong-Seok; Kim, Dong-Kwon; Lee, Jong-Hyun
2000-12-01
Probe card is most important part in the test system which selects the good or bad chip of integrated circuit (IC) chips. Silicon vertical probe card is able to test multiple semiconductor chips simultaneously. We presented cantilever-bump type vertical probe card. It was fabricated by dry etching using RIE(reactive ion etching) technique and porous silicon micromachining using silicon direct bonded (SDB) wafer. Cantilevers and bumps were fabricated by isotropic etching using RIE@. 3-dimensional structures were formed by porous silicon micromachining technique using SDB wafer. Contact resistance of fabricated probe card was less than 2 Ω and its life time was more than 200,000 turns. The process used in this work is very simple and reproducible, which has good controllability in the tip dimension and spacing. It is expected that the fabricated probe card can reduce testing time, can promote productivity and enables burn-in test.
Hubbell, Joel M.; Sisson, James B.
2005-07-26
A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.
Experimental investigation of hypersonic aerodynamics
NASA Technical Reports Server (NTRS)
Heinemann, K.; Intrieri, Peter F.
1987-01-01
An extensive series of ballistic range tests are currently being conducted at the Ames Research Center. These tests are intended to investigate the hypersonic aerodynamic characteristics of two basic configurations, which are: the blunt-cone Galileo probe which is scheduled to be launched in late 1989 and will enter the atmosphere of Jupiter in 1994, and a generic slender cone configuration to provide experimental aerodynamic data including good flow-field definition which computational aerodynamicists could use to validate their computer codes. Some of the results obtained thus far are presented and work for the near future is discussed.
NASA Technical Reports Server (NTRS)
Anthony, P. L.; Mcmurtrey, J. E.
1971-01-01
The development of a nondestructive test with the capability to interrogate plated-through holes as small as 0.51 millimeters inside diameter is discussed. The system can detect defects such as holes, voids, cracks, and thin spots that reduce the current carrying capability of plates-through interconnects by 20 percent or more. Efforts were directed toward the design and fabrication of magnetic circuitry mutual coupling probes and to evaluate the effectiveness of these devices for detecting in multilayer board plated-through holes.
Gravitational wave probes of parity violation in compact binary coalescences
NASA Astrophysics Data System (ADS)
Alexander, Stephon H.; Yunes, Nicolás
2018-03-01
Is gravity parity violating? Given the recent observations of gravitational waves from coalescing compact binaries, we develop a strategy to find an answer with current and future detectors. We identify the key signatures of parity violation in gravitational waves: amplitude birefringence in their propagation and a modified chirping rate in their generation. We then determine the optimal binaries to test the existence of parity violation in gravity, and prioritize the research in modeling that will be required to carry out such tests before detectors reach their design sensitivity.
Cimarelli, Lucia; Singh, Kumar Saurabh; Mai, Nguyen Thi Nhu; Dhar, Bidhan Chandra; Brandi, Anna; Brandi, Letizia; Spurio, Roberto
2015-05-22
Our understanding of the composition of diatom communities and their response to environmental changes is currently limited by laborious taxonomic identification procedures. Advances in molecular technologies are expected to contribute more efficient, robust and sensitive tools for the detection of these ecologically relevant microorganisms. There is a need to explore and test phylogenetic markers as an alternative to the use of rRNA genes, whose limited sequence divergence does not allow the accurate discrimination of diatoms at the species level. In this work, nine diatom species belonging to eight genera, isolated from epylithic environmental samples collected in central Italy, were chosen to implement a panel of diatoms covering the full range of ecological status of freshwaters. The procedure described in this work relies on the PCR amplification of specific regions in two conserved diatom genes, elongation factor 1-a (eEF1-a) and silicic acid transporter (SIT), as a first step to narrow down the complexity of the targets, followed by microarray hybridization experiments. Oligonucleotide probes with the potential to discriminate closely related species were designed taking into account the genetic polymorphisms found in target genes. These probes were tested, refined and validated on a small-scale prototype DNA chip. Overall, we obtained 17 highly specific probes targeting eEF1-a and SIT, along with 19 probes having lower discriminatory power recognizing at the same time two or three species. This basic array was validated in a laboratory setting and is ready for tests with crude environmental samples eventually to be scaled-up to include a larger panel of diatoms. Its possible use for the simultaneous detection of diatoms selected from the classes of water quality identified by the European Water Framework Directive is discussed.
Methods of and apparatus for levitating an eddy current probe
Stone, William J.
1988-05-03
An eddy current probe is supported against the force of gravity with an air earing while being urged horizontally toward the specimen being examined by a spring and displaced horizontally against the force of the spring pneumatically. The pneumatic displacement is accomplished by flowing air between a plenum chamber fixed with respect to the probe and the surface of the specimen. In this way, the surface of the specimen can be examined without making mechanical contact therewith while precisely controlling the distance at which the probe stands-off from the surface of the specimen.
Operation of a swept Langmuir probe on a sounding rocket
NASA Astrophysics Data System (ADS)
Robertson, S. H.; Dickson, S.; Friedrich, M.; Sternovsky, Z.
2012-12-01
A swept cylindrical Langmuir probe was operated on two sounding rockets from ~ 60-120 km for the purpose of determining both the ambient electron density and the payload potential relative to the ambient plasma. The rockets were part of the CHAMPS (CHarge And mass of Meteoritic smoke ParticleS) rocket campaign and carried mass analyzers and various plasma probes to study charged meteoritic dust in the mesopause region. The payload potential is an important parameter for data interpretation. The rockets were launched in October of 2011 from Andøya Rocket Range, Norway. The launches were a few days apart with one taking place during the day and the other at night. The swept Langmuir probe data provided a current-voltage characteristic that had a distinct "knee" indicating the onset of electron collection; the probe voltage at this "knee" corresponds to the ambient plasma potential. The data indicate a payload potential of about -2 V to -1 V for both launches. The payload potential becomes less negative for altitudes above 80 km on the day launch due to photoemission. The probe current-voltage data are also compared with ion and electron density measurements from ion probes and Faraday rotation antennas, respectively. The data from the various instruments are in general agreement. Further consideration of the Langmuir probe performance shows that if the probe had been operated with feedback control to continuously collect electrons with a current of order 1 microamp, the probe potential would be an accurate, continuous indicator of the payload potential without the need for sweeping which could periodically alter the payload potential.
Capacitively coupled RF voltage probe having optimized flux linkage
Moore, James A.; Sparks, Dennis O.
1999-02-02
An RF sensor having a novel current sensing probe and a voltage sensing probe to measure voltage and current. The current sensor is disposed in a transmission line to link all of the flux generated by the flowing current in order to obtain an accurate measurement. The voltage sensor is a flat plate which operates as a capacitive plate to sense voltage on a center conductor of the transmission line, in which the measured voltage is obtained across a resistance leg of a R-C differentiator circuit formed by the characteristic impedance of a connecting transmission line and a capacitance of the plate, which is positioned proximal to the center conductor.
Probing of multiple magnetic responses in magnetic inductors using atomic force microscopy.
Park, Seongjae; Seo, Hosung; Seol, Daehee; Yoon, Young-Hwan; Kim, Mi Yang; Kim, Yunseok
2016-02-08
Even though nanoscale analysis of magnetic properties is of significant interest, probing methods are relatively less developed compared to the significance of the technique, which has multiple potential applications. Here, we demonstrate an approach for probing various magnetic properties associated with eddy current, coil current and magnetic domains in magnetic inductors using multidimensional magnetic force microscopy (MMFM). The MMFM images provide combined magnetic responses from the three different origins, however, each contribution to the MMFM response can be differentiated through analysis based on the bias dependence of the response. In particular, the bias dependent MMFM images show locally different eddy current behavior with values dependent on the type of materials that comprise the MI. This approach for probing magnetic responses can be further extended to the analysis of local physical features.
NASA Astrophysics Data System (ADS)
Mouikis, Christopher; Bingham, Samuel; Kistler, Lynn; Spence, Harlan; Gkioulidou, Matina
2017-04-01
The ring current responds differently to the different solar and interplanetary storm drivers such as coronal mass injections, (CME's), and co-rotating interaction regions (CIR's). Using Van Allen Probes observations, we develop an empirical ring current model of the ring current pressure, the pressure anisotropy and the current density development during the storm phases for both types of storm drivers and for all MLTs inside L 6. Delineating the differences in the ring current development between these two drivers will aid our understanding of the ring current dynamics. We find that during the storm main phase most of the ring current pressure in the pre-midnight inner magnetosphere is contributed by particles on open drift paths that cause the development of a strong partial ring current that causes most of the main phase Dst drop. These particles can reach as deep as L 2 and their pressure compares to the local magnetic field pressure as deep as L 3. During the recovery phase, if these particles are not lost at the magnetopause, will become trapped and will contribute to the symmetric ring current. However, the largest difference between the CME and CIR ring current responses during the storm main and early recovery phases is caused by how the 15 - 60 keV O+ responds to these drivers. This empirical model is compared to the results of CIMI simulations of a CMEs and a CIRs where the model input is comprised of the superposed epoch solar wind conditions of the storms that comprise the empirical model. Different inner magnetosphere boundary conditions are tested in order to match the empirical model results. Comparing the model and simulation results improves our understanding of the ring current dynamics as part of the highly coupled inner magnetosphere system. In addition, within the framework of this empirical model, the prediction of the EMIC wave generation linear theory is tested using the observed plasma parameters and comparing with the observations of EMIC waves.
Wind-Tunnel Tests of Seven Static-Pressure Probes at Transonic Speeds
NASA Technical Reports Server (NTRS)
Capone, Francis J.
1961-01-01
Wind-tunnel tests have been conducted to determine the errors of 3 seven static-pressure probes mounted very close to the nose of a body of revolution simulating a missile forebody. The tests were conducted at Mach numbers from 0.80 to 1.08 and at angles of attack from -1.7 deg to 8.4 deg. The test Reynolds number per foot varied from 3.35 x 10(exp 6) to 4.05 x 10(exp 6). For three 4-vane, gimbaled probes, the static-pressure errors remained constant throughout the test angle-of-attack range for all Mach numbers except 1.02. For two single-vane, self-rotating probes having two orifices at +/-37.5 deg. from the plane of symmetry on the lower surface of the probe body, the static-pressure error varied as much as 1.5 percent of free-stream static pressure through the test angle-of- attack range for all Mach numbers. For two fixed, cone-cylinder probes of short length and large diameter, the static-pressure error varied over the test angle-of-attack range at constant Mach numbers as much as 8 to 10 percent of free-stream static pressure.
Evans, Travis C; Britton, Jennifer C
2018-09-01
Abnormal threat-related attention in anxiety disorders is most commonly assessed and modified using the dot-probe paradigm; however, poor psychometric properties of reaction-time measures may contribute to inconsistencies across studies. Typically, standard attention measures are derived using average reaction-times obtained in experimentally-defined conditions. However, current approaches based on experimentally-defined conditions are limited. In this study, the psychometric properties of a novel response-based computation approach to analyze dot-probe data are compared to standard measures of attention. 148 adults (19.19 ± 1.42 years, 84 women) completed a standardized dot-probe task including threatening and neutral faces. We generated both standard and response-based measures of attention bias, attentional orientation, and attentional disengagement. We compared overall internal consistency, number of trials necessary to reach internal consistency, test-retest reliability (n = 72), and criterion validity obtained using each approach. Compared to standard attention measures, response-based measures demonstrated uniformly high levels of internal consistency with relatively few trials and varying improvements in test-retest reliability. Additionally, response-based measures demonstrated specific evidence of anxiety-related associations above and beyond both standard attention measures and other confounds. Future studies are necessary to validate this approach in clinical samples. Response-based attention measures demonstrate superior psychometric properties compared to standard attention measures, which may improve the detection of anxiety-related associations and treatment-related changes in clinical samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
The Space High Angular Resolution Probe for the Infrared (SHARP-IR)
NASA Technical Reports Server (NTRS)
Rinehart, S. A.; Rizzo, M. J.; Leisawitz, D. T.; Staguhn, J. G.; Dipirro, M.; Mentzell, J. E.; Juanola-Parramon, R.; Dhabal, A.; Mundy, L. G.; Moseley, S. H.;
2016-01-01
The Space High Angular Resolution Probe for the Infrared (SHARP-IR) is a new mission currently under study. As partof the preparation for the Decadal Survey, NASA is currently undertaking studies of four major missions, but interesthas also been shown in determining if there are feasible sub-$1B missions that could provide significant scientific return.SHARP-IR is being designed as one such potential probe. In this talk, we will discuss some of the potential scientificquestions that could be addressed with the mission, the current design, and the path forward to concept maturation.
A noninterference blade vibration measurement system for gas turbine engines
NASA Astrophysics Data System (ADS)
Watkins, William B.; Chi, Ray M.
1987-06-01
A noninterfering blade vibration system has been demonstrated in tests of a gas turbine first stage fan. Conceptual design of the system, including its theory, design of case mounted probes, and data acquisition and signal processing hardware was done in a previous effort. The current effort involved instrumentation of an engine fan stage with strain gages; data acquisition using shaft-mounted reference and case-mounted optical probes; recording of data on a wideband tape recorder; and posttest processing using off-line analysis in a facility computer and a minicomputer-based readout system designed for near- real-time readout. Results are presented in terms of true blade vibration frequencies, time and frequency dependent vibration amplitudes and comparison of the optical noninterference results with strain gage readings.
Hollox, E J; Atia, T; Cross, G; Parkin, T; Armour, J A L
2002-11-01
Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone.
Hollox, E; Atia, T; Cross, G; Parkin, T; Armour, J
2002-01-01
Background: Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. Methods: We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. Results: The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. Conclusions: MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone. PMID:12414816
Fluorescence In Situ Hybridization Probe Validation for Clinical Use.
Gu, Jun; Smith, Janice L; Dowling, Patricia K
2017-01-01
In this chapter, we provide a systematic overview of the published guidelines and validation procedures for fluorescence in situ hybridization (FISH) probes for clinical diagnostic use. FISH probes-which are classified as molecular probes or analyte-specific reagents (ASRs)-have been extensively used in vitro for both clinical diagnosis and research. Most commercially available FISH probes in the United States are strictly regulated by the U.S. Food and Drug Administration (FDA), the Centers for Disease Control and Prevention (CDC), the Centers for Medicare & Medicaid Services (CMS) the Clinical Laboratory Improvement Amendments (CLIA), and the College of American Pathologists (CAP). Although home-brewed FISH probes-defined as probes made in-house or acquired from a source that does not supply them to other laboratories-are not regulated by these agencies, they too must undergo the same individual validation process prior to clinical use as their commercial counterparts. Validation of a FISH probe involves initial validation and ongoing verification of the test system. Initial validation includes assessment of a probe's technical specifications, establishment of its standard operational procedure (SOP), determination of its clinical sensitivity and specificity, development of its cutoff, baseline, and normal reference ranges, gathering of analytics, confirmation of its applicability to a specific research or clinical setting, testing of samples with or without the abnormalities that the probe is meant to detect, staff training, and report building. Ongoing verification of the test system involves testing additional normal and abnormal samples using the same method employed during the initial validation of the probe.
Design and testing of a shrouded probe for airborne aerosol sampling in a high velocity airstream
NASA Astrophysics Data System (ADS)
Cain, Stuart Arthur
1997-07-01
Tropospheric aerosols play an important role in many phenomena related to global climate and climate change and two important parameters, aerosol size distribution and concentration, have been the focus of a great deal of attention. To study these parameters it is necessary to obtain a representative sample of the ambient aerosol using an airborne aerosol sampling probe mounted on a suitably equipped aircraft. Recently, however, serious questions have been raised (Huebert et al., 1990; Baumgardner et al., 1991) concerning the current procedures and techniques used in airborne aerosol sampling. We believe that these questions can be answered by: (1) use of a shrouded aerosol sampling probe, (2) proper aerodynamic sampler design using numerical simulation techniques, (3) calculation of the sampler calibration curve to be used in determining free-stream aerosol properties from measurements made with the sampler and (4) wind tunnel tests to verify the design and investigate the performance of the sampler at small angles of attack (typical in airborne sampling applications due to wind gusts and aircraft fuel consumption). Our analysis is limited to the collection of insoluble particles representative of the global tropospheric 'background aerosol' (0.1-2.6 μm diameter) whose characteristics are least likely to be affected by the collection process. We begin with a survey of the most relevant problems associated with current airborne aerosol samplers and define the physical quantity that we wish to measure. This includes the derivation of a unique mathematical expression relating the free-stream aerosol size distribution to aerosol data obtained from the airborne measurements with the sampler. We follow with the presentation of the results of our application of Computational Fluid Dynamics (CFD) and Computational Particle Dynamics (CPD) to the design of a shrouded probe for airborne aerosol sampling of insoluble tropospheric particles in the size range 0.1 to 15 μm diameter at an altitude of 6069 m (20,000 ft) above sea level (asl). Our aircraft of choice is the National Center for Atmospheric Research (NCAR) EC-130 Geoscience Research aircraft whose cruising speed at a sampling altitude of 6069 m asl is 100 m/s. We calculate the aspiration efficiency of the sampler and estimate the transmission efficiency of the diffuser probe based on particle trajectory simulations. We conclude by presenting the results of a series of qualitative and quantitative wind tunnel tests of the airflow through a plexiglass prototype of the sampler to verify our numerical simulations and predict the performance of the sampler at angles of attack from 0o to 15o.
A computerized Langmuir probe system
NASA Astrophysics Data System (ADS)
Pilling, L. S.; Bydder, E. L.; Carnegie, D. A.
2003-07-01
For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of ±70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA-100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier.
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
Code of Federal Regulations, 2014 CFR
2014-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
Code of Federal Regulations, 2012 CFR
2012-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2012 CFR
2012-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2013 CFR
2013-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2011 CFR
2011-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
49 CFR 572.43 - Lumbar spine and pelvis.
Code of Federal Regulations, 2014 CFR
2014-10-01
... laterally by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b) of this... horizontally forward. (2) Place the longitudinal centerline of the test probe at the lateral side of the pelvis... vertical plane which is tangent to the back of the dummy's buttocks. (3) Align the test probe so that at...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
16 CFR Figure 2 to Part 1513 - Test Probe for Neck Entrapment
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test Probe for Neck Entrapment 2 Figure 2 to Part 1513 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BUNK BEDS Pt. 1513, Fig. 2 Figure 2 to Part 1513—Test Probe for Neck Entrapment...
Code of Federal Regulations, 2011 CFR
2011-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
16 CFR § 1505.51 - Hot surfaces.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
Code of Federal Regulations, 2013 CFR
2013-10-01
... each of the drawings subtended therein. (b) When impacted by a test probe conforming to § 572.36(a) at... measured by the test probe and shall have a sternum displacement measured relative to spine of 2.68 inches.... 208 (§ 571.208 of this chapter). EC01AU91.166 (3) Place the longitudinal centerline of the test probe...
NASA Technical Reports Server (NTRS)
Klenzing, J.; Rowland, D.
2012-01-01
A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.
Testing the strong equivalence principle with the triple pulsar PSR J 0337 +1715
NASA Astrophysics Data System (ADS)
Shao, Lijing
2016-04-01
Three conceptually different masses appear in equations of motion for objects under gravity, namely, the inertial mass, mI , the passive gravitational mass, mP, and the active gravitational mass, mA. It is assumed that, for any objects, mI=mP=mA in the Newtonian gravity, and mI=mP in the Einsteinian gravity, oblivious to objects' sophisticated internal structure. Empirical examination of the equivalence probes deep into gravity theories. We study the possibility of carrying out new tests based on pulsar timing of the stellar triple system, PSR J 0337 +1715 . Various machine-precision three-body simulations are performed, from which, the equivalence-violating parameters are extracted with Markov chain Monte Carlo sampling that takes full correlations into account. We show that the difference in masses could be probed to 3 ×1 0-8 , improving the current constraints from lunar laser ranging on the post-Newtonian parameters that govern violations of mP=mI and mA=mP by thousands and millions, respectively. The test of mP=mA would represent the first test of Newton's third law with compact objects.
Comparative testing of pulse oximeter probes.
van Oostrom, Johannes H; Melker, Richard J
2004-05-01
The testing of pulse oximeter probes is generally limited to the integrity of the electrical circuit and does not include the optical properties of the probes. Few pulse oximeter testers evaluate the accuracy of both the monitor and the probe. We designed a study to compare the accuracy of nonproprietary probes (OSS Medical) designed for use with Nellcor, Datex-Ohmeda, and Criticare pulse oximeter monitors with that of their corresponding proprietary probes by using a commercial off-the-shelf pulse oximeter tester (Index). The Index pulse oximeter tester does include testing of the optical properties of the pulse oximeter probes. The pulse oximeter tester was given a controlled input that simulated acute apnea. Desaturation curves were automatically recorded from the pulse oximeter monitors with a data-collection computer. Comparisons between equivalent proprietary and nonproprietary probes were performed. Data were analyzed by using univariate and multivariate general linear model analysis. Five OSS Medical probe models were statistically better than the equivalent proprietary probes. The remainder of the probes were statistically similar. Comparative and simulation studies can have significant advantages over human studies because they are cost-effective, evaluate equipment in a clinically relevant scenario, and pose no risk to patients, but they are limited by the realism of the simulation. We studied the performance of pulse oximeter probes in a simulated environment. Our results show significant differences between some probes that affect the accuracy of measurement.
Some experiments with the tunnel probe in a low temperature magnetized plasma
NASA Astrophysics Data System (ADS)
Kovačič, J.; Gyergyek, T.; Kavaš, B.; Vodnik, M.; Kavčič, J.; Gunn, J. P.
2018-02-01
Experiments were performed using a Tunnel Probe (TP) inside the weakly-ionised plasma of the Linear Magnetized Plasma Device (LMPD). The TP is designed as a concave probe, which should annihilate the problem of sheath expansion in the ion branch of the I-V characteristic. As the ion saturation current is consequently well defined, the ion parallel current and plasma density can be more accurately calculated. Furthermore the ratio between the ion saturation currents on the two collectors (tunnel ring and the back-plate) can be used to derive the electron temperature. The TP has been repeatedly used with success on the former Castor and Tore-Supra tokamaks and will be used on the upgraded version of Tore-supra, namely the WEST tokamak, as well [1, 2]. It was however never used successfully in a low-temperature plasma. We studied the feasibility of the TP use in a low-temperature plasma for direct measurements of plasma temperature and density. The various probe characteristic dimensions, such as the distance between the two collectors, the aperture size and the probe radius were varied to see influence of the individual probe feature. We also varied the level of magnetization of the charged particle species, the background gas pressure (which influences the electron energy distribution function), the plasma density (important for the ratio between the λ D and the ion Larmor radius). The sensitivity of the probe alignment to the magnetic field lines was also studied. We found, that the ion saturation current does not necessarily saturate and that the probe works according to expectations only in a limited amount of regimes.
Probing Shells Against Buckling: A Nondestructive Technique for Laboratory Testing
NASA Astrophysics Data System (ADS)
Thompson, J. Michael T.; Hutchinson, John W.; Sieber, Jan
2017-12-01
This paper addresses testing of compressed structures, such as shells, that exhibit catastrophic buckling and notorious imperfection sensitivity. The central concept is the probing of a loaded structural specimen by a controlled lateral displacement to gain quantitative insight into its buckling behavior and to measure the energy barrier against buckling. This can provide design information about a structure’s stiffness and robustness against buckling in terms of energy and force landscapes. Developments in this area are relatively new but have proceeded rapidly with encouraging progress. Recent experimental tests on uniformly compressed spherical shells, and axially loaded cylinders, show excellent agreement with theoretical solutions. The probing technique could be a valuable experimental procedure for testing prototype structures, but before it can be used a range of potential problems must be examined and solved. The probing response is highly nonlinear and a variety of complications can occur. Here, we make a careful assessment of unexpected limit points and bifurcations, that could accompany probing, causing complications and possibly even collapse of a test specimen. First, a limit point in the probe displacement (associated with a cusp instability and fold) can result in dynamic buckling as probing progresses, as demonstrated in the buckling of a spherical shell under volume control. Second, various types of bifurcations which can occur on the probing path which result in the probing response becoming unstable are also discussed. To overcome these problems, we outline the extra controls over the entire structure that may be needed to stabilize the response.
Behavioral and neural stability of attention bias to threat in healthy adolescents
Britton, Jennifer C.; Sequeira, Stefanie; Ronkin, Emily G.; Chen, Gang; Bar-Haim, Yair; Shechner, Tomer; Ernst, Monique; Fox, Nathan A.; Leibenluft, Ellen; Pine, Daniel S.
2016-01-01
Considerable translational research on anxiety examines attention bias to threat and the efficacy of attention training in reducing symptoms. Imaging research on the stability of brain functions engaged by attention bias tasks could inform such research. Perturbed fronto-amygdala function consistently arises in attention bias research on adolescent anxiety. The current report examines the stability of the activation and functional connectivity of these regions on the dot-probe task. Functional magnetic resonance imaging (fMRI) activation and connectivity data were acquired with the dot-probe task in 39 healthy youth (f =18, Mean Age = 13.71 years, SD = 2.31) at two time points, separated by approximately nine weeks. Intraclass-correlations demonstrate good reliability in both neural activation for the ventrolateral PFC and task-specific connectivity for fronto-amygdala circuitry. Behavioral measures showed generally poor test-retest reliability. These findings suggest potential avenues for future brain imaging work by highlighting brain circuitry manifesting stable functioning on the dot-probe attention bias task. PMID:27129757
NASA Astrophysics Data System (ADS)
Roshila, M. L.; Hashim, U.; Azizah, N.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.
2017-03-01
This paper principally delineates to the detection process of Human Papillomavirus (HPV) DNA test. HPV is an extremely common virus infection that infected to human by the progressions cell in the cervix cell. The types of HPV that give a most exceedingly awful infected with cervical cancer is 16 and 18 other than 31 and 45. The HPV DNA probe is immobilized with a different concentration to stabilize the sensitivity. A technique of rapid and sensitive for the HPV identification was proposed by coordinating basic DNA extraction with a quality of DNA. The extraction of the quality of DNA will make a proficiency of the discovery procedure. It will rely on the sequence of the capture probes and the way to support their attached. The fabrication, surface modification, immobilization and hybridization procedures are described by current-voltage (I-V) estimation by utilizing KEITHLEY 6487. This procedure will play out a decent affectability and selectivity of HPV discovery.
NDT of fiber-reinforced composites with a new fiber-optic pump–probe laser-ultrasound system☆
Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; O’Donnell, Matthew
2014-01-01
Laser-ultrasonics is an attractive and powerful tool for the non-destructive testing and evaluation (NDT&E) of composite materials. Current systems for non-contact detection of ultrasound have relatively low sensitivity compared to contact peizotransducers. They are also expensive, difficult to adjust, and strongly influenced by environmental noise. Moreover, laser-ultrasound (LU) systems typically launch only about 50 firings per second, much slower than the kHz level pulse repetition rate of conventional systems. As demonstrated here, most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive, high repetition rate nanosecond fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe beam detector. In particular, a modified fiber-optic balanced Sagnac interferometer is presented as part of a LU pump–probe system for NDT&E of aircraft composites. The performance of the all-optical system is demonstrated for a number of composite samples with different types and locations of inclusions. PMID:25302156
Photoacoustic measurement of epidermal melanin
NASA Astrophysics Data System (ADS)
Viator, John A.; Svaasand, Lars O.; Aguilar, Guillermo; Choi, Bernard; Nelson, J. Stuart
2003-06-01
Most dermatologic laser procedures must consider epidermal melanin, as it is a broadband optical absorber which affects subsurface fluence, effectively limiting the amount of light reaching the dermis and targeted chromophores. An accurate method for quantifying epidermal melanin content would aid clinicians in determining proper light dosage for therapeutic laser procedures. While epidermal melanin content has been quantified non-invasively using optical methods, there is currently no way to determine the melanin distribution in the epidermis. We have developed a photoacoustic probe that uses a Q-switched, frequency doubled Nd:YAG laser operating at 532nm to generate acoustic pulses in skin in vivo. The probe contained a piezoelectric element that detected photoacoustic waves which were then analyzed for epidermal melanin content, using a photoacoustic melanin index (PAMI). We tested 15 human subjects with skin types I--VI using the photoacoustic probe. We also present photoacoustic data for a human subject with vitiligo. Photoacoustic measurement showed melanin in the vitiligo subject was almost completely absent.
Gallium Electromagnetic (GEM) Thruster Performance Measurements
NASA Technical Reports Server (NTRS)
Thomas, Robert E.; Burton, Rodney L.; Polzin, K. A.
2009-01-01
Discharge current, terminal voltage, and mass bit measurements are performed on a coaxial gallium electromagnetic thruster at discharge currents in the range of 7-23 kA. It is found that the mass bit varies quadratically with the discharge current which yields a constant exhaust velocity of 20 km/s. Increasing the electrode radius ratio of the thruster from to 2.6 to 3.4 increases the thruster efficiency from 21% to 30%. When operating with a central gallium anode, macroparticles are ejected at all energy levels tested. A central gallium cathode ejects macroparticles when the current density exceeds 3.7 10(exp 8) A/square m . A spatially and temporally broad spectroscopic survey in the 220-520 nm range is used to determine which species are present in the plasma. The spectra show that neutral, singly, and doubly ionized gallium species are present in the discharge, as well as annular electrode species at higher energy levels. Axial Langmuir triple probe measurements yield electron temperatures in the range of 0.8-3.8 eV and electron densities in the range of 8 x 10(exp )20 to 1.6 x 10(exp 21) m(exp -3) . Triple probe measurements suggest an exhaust plume with a divergence angle of 9 , and a completely doubly ionized plasma at the ablating thruster cathode.
Automated eddy current analysis of materials
NASA Technical Reports Server (NTRS)
Workman, Gary L.
1991-01-01
The use of eddy current techniques for characterizing flaws in graphite-based filament-wound cylindrical structures is described. A major emphasis was also placed upon incorporating artificial intelligence techniques into the signal analysis portion of the inspection process. Developing an eddy current scanning system using a commercial robot for inspecting graphite structures (and others) was a goal in the overall concept and is essential for the final implementation for the expert systems interpretation. Manual scans, as performed in the preliminary work here, do not provide sufficiently reproducible eddy current signatures to be easily built into a real time expert system. The expert systems approach to eddy current signal analysis requires that a suitable knowledge base exist in which correct decisions as to the nature of a flaw can be performed. A robotic workcell using eddy current transducers for the inspection of carbon filament materials with improved sensitivity was developed. Improved coupling efficiencies achieved with the E-probes and horseshoe probes are exceptional for graphite fibers. The eddy current supervisory system and expert system was partially developed on a MacIvory system. Continued utilization of finite element models for predetermining eddy current signals was shown to be useful in this work, both for understanding how electromagnetic fields interact with graphite fibers, and also for use in determining how to develop the knowledge base. Sufficient data was taken to indicate that the E-probe and the horseshoe probe can be useful eddy current transducers for inspecting graphite fiber components. The lacking component at this time is a large enough probe to have sensitivity in both the far and near field of a thick graphite epoxy component.
Results and Conclusions from the NASA Isokinetic Total Water Content Probe 2009 IRT Test
NASA Technical Reports Server (NTRS)
Reehorst, Andrew; Brinker, David
2010-01-01
The NASA Glenn Research Center has developed and tested a Total Water Content Isokinetic Sampling Probe. Since, by its nature, it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument comprises the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Results and conclusions are presented from probe tests in the NASA Glenn Icing Research Tunnel (IRT) during January and February 2009. The use of reference probe heat and the control of air pressure in the water vapor measurement subsystem are discussed. Several run-time error sources were found to produce identifiable signatures that are presented and discussed. Some of the differences between measured Isokinetic Total Water Content Probe and IRT calibration seems to be caused by tunnel humidification and moisture/ice crystal blow around. Droplet size, airspeed, and liquid water content effects also appear to be present in the IRT calibration. Based upon test results, the authors provide recommendations for future Isokinetic Total Water Content Probe development.
Powell, Michael L; Bowler, Frank R; Martinez, Aurore J; Greenwood, Catherine J; Armes, Niall; Piepenburg, Olaf
2018-02-15
Rapid, cost-effective and sensitive detection of nucleic acids has the ability to improve upon current practices employed for pathogen detection in diagnosis of infectious disease and food testing. Furthermore, if assay complexity can be reduced, nucleic acid amplification tests could be deployed in resource-limited and home use scenarios. In this study, we developed a novel Fpg (Formamidopyrimidine DNA glycosylase) probe chemistry, which allows lateral flow detection of amplification in undiluted recombinase polymerase amplification (RPA) reactions. The prototype nucleic acid lateral flow chemistry was applied to a human genomic target (rs1207445), Campylobacter jejuni 16S rDNA and two genetic markers of the important food pathogen E. coli O157:H7. All four assays have an analytical sensitivity between 10 and 100 copies DNA per amplification. Furthermore, the assay is performed with fewer hands-on steps than using the current RPA Nfo lateral flow method as dilution of amplicon is not required for lateral flow analysis. Due to the simplicity of the workflow, we believe that the lateral flow chemistry for direct detection could be readily adapted to a cost-effective single-use consumable, ideal for use in non-laboratory settings. Copyright © 2017. Published by Elsevier Inc.
Chen, You-Yin; Lai, Hsin-Yi; Lin, Sheng-Huang; Cho, Chien-Wen; Chao, Wen-Hung; Liao, Chia-Hsin; Tsang, Siny; Chen, Yi-Fan; Lin, Si-Yue
2009-08-30
The design and testing of a new microelectrode array, the NCTU (National Chiao Tung University) probe, was presented. Evaluation results showed it has good biocompatibility, high signal-to-noise ratio (SNR: the root mean square of background noise to the average peak-to-peak amplitude of spikes) during chronic neural recordings, and high reusability for electrolytic lesions. The probe was a flexible, polyimide-based microelectrode array with a long shaft (14.9 mm in length) and 16 electrodes (5 microm-thick and 16 microm in radius); its performance in chronic in vivo recordings was examined in rodents. To improve the precision of implantation, a metallic, impact-resistant layer was sandwiched between the polyimide layers to strengthen the probe. The three-dimensional (3D) structure of electrodes fabricated by electroplating produced rough textures that increased the effective surface area. The in vitro impedance of electrodes on the NCTU probe was 2.4+/-0.52 MOmega at 1 kHz. In addition, post-surgical neural recordings of implanted NCTU probes were conducted for up to 40 days in awake, normally behaving rats. The electrodes on the NCTU probe functioned well and had a high SNR (range: 4-5) with reliable in vivo impedance (<0.7 MOmega). The electrodes were also robust enough to functionally record events, even after the anodal current (30 microA, 10s) was repeatedly applied for 60 times. With good biocompatibility, high and stable SNR for chronic recording, and high tolerance for electrolytic lesion, the NCTU probe would serve as a useful device in future neuroscience research.
NASA Technical Reports Server (NTRS)
Power, J. L.
1984-01-01
Preliminary ground correlation testing has been conducted with an 8 cm mercury ion thruster and diagnostic instrumentation replicating to a large extent the IAPS flight test hardware, configuration, and electrical grounding/isolation. Thruster efflux deposition retained at 25 C was measured and characterized. Thruster ion efflux was characterized with retarding potential analyzers. Thruster-generated plasma currents, the spacecraft common (SCC) potential, and ambient plasma properties were evaluated with a spacecraft potential probe (SPP). All the measured thruster/spacecraft interactions or their IAPS measurements depend critically on the SCC potential, which can be controlled by a neutralizer ground switch and by the SPP operation.
NASA Astrophysics Data System (ADS)
Chen, Xin; Sánchez-Arriaga, Gonzalo
2018-02-01
To model the sheath structure around an emissive probe with cylindrical geometry, the Orbital-Motion theory takes advantage of three conserved quantities (distribution function, transverse energy, and angular momentum) to transform the stationary Vlasov-Poisson system into a single integro-differential equation. For a stationary collisionless unmagnetized plasma, this equation describes self-consistently the probe characteristics. By solving such an equation numerically, parametric analyses for the current-voltage (IV) and floating-potential (FP) characteristics can be performed, which show that: (a) for strong emission, the space-charge effects increase with probe radius; (b) the probe can float at a positive potential relative to the plasma; (c) a smaller probe radius is preferred for the FP method to determine the plasma potential; (d) the work function of the emitting material and the plasma-ion properties do not influence the reliability of the floating-potential method. Analytical analysis demonstrates that the inflection point of an IV curve for non-emitting probes occurs at the plasma potential. The flat potential is not a self-consistent solution for emissive probes.
Phase I Experimental Testing of a Generic Submarine Model in the DSTO Low Speed Wind Tunnel
2012-07-01
used during the tests , along with the test methodology . A sub-set of the data gathered is also presented and briefly discussed. Overall, the force...total pressure probe when positioned close to the model. 4. Results Selected results from the testing of the generic submarine model in the...Appendix B summaries the test conditions. 4.3.1 Smoke Generator and Probe An Aerotech smoke generator and probe were used for visualisation of
Martin, Alexandra; Bouffier, Laurent; Grant, Kathryn B; Limoges, Benoît; Marchal, Damien
2016-06-20
We present a comparative study of ten redox-active probes for use in real-time electrochemical loop-mediated isothermal amplification (LAMP). Our main objectives were to establish the criteria that need to be fulfilled for minimizing some of the current limitations of the technique and to provide future guidelines in the search for ideal redox reporters. To ensure a reliable comparative study, each redox probe was tested under similar conditions using the same LAMP reaction and the same entirely automatized custom-made real-time electrochemical device (designed for electrochemically monitoring in real-time and in parallel up to 48 LAMP samples). Electrochemical melt curve analyses were recorded immediately at the end of each LAMP reaction. Our results show that there are a number of intercalating and non-intercalating redox compounds suitable for real-time electrochemical LAMP and that the best candidates are those able to intercalate strongly into ds-DNA but not too much to avoid inhibition of the LAMP reaction. The strongest intercalating redox probes were finally shown to provide higher LAMP sensitivity, speed, greater signal amplitude, and cleaner-cut DNA melting curves than the non-intercalating molecules.
Fabrication and surface-modification of implantable microprobes for neuroscience studies
NASA Astrophysics Data System (ADS)
Cao, H.; Nguyen, C. M.; Chiao, J. C.
2012-06-01
In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor-liquid-solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H2O2, electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors.
Imminent Engine Failure Probe Investigation.
probe signature determination, development of data recording techniques, accumulation of data during durability testing of T56 or TF41 engines and...any other opportunistic gas turbine engine test. The electrostatic probe demonstrated some capability to detect engine distress in TF41 and T56 engines
The Lewis Research Center geomagnetic substorm simulation facility
NASA Technical Reports Server (NTRS)
Berkopec, F. D.; Stevens, N. J.; Sturman, J. C.
1977-01-01
A simulation facility was established to determine the response of typical spacecraft materials to the geomagnetic substorm environment and to evaluate instrumentation that will be used to monitor spacecraft system response to this environment. Space environment conditions simulated include the thermal-vacuum conditions of space, solar simulation, geomagnetic substorm electron fluxes and energies, and the low energy plasma environment. Measurements for spacecraft material tests include sample currents, sample surface potentials, and the cumulative number of discharges. Discharge transients are measured by means of current probes and oscilloscopes and are verified by a photomultiplier. Details of this facility and typical operating procedures are presented.
Measurements of monopolar and bipolar current spreads using forward-masking with a fixed probe.
Bingabr, Mohamed G; Espinoza-Varas, Blas; Sigdel, Saroj
2014-05-01
This research employed a forward-masking paradigm to estimate the current spread of monopolar (MP) and bipolar (BP) maskers, with current amplitudes adjusted to elicit the same loudness. Since the spatial separation between active and return electrodes is smaller in BP than in MP configurations, the BP current spread is more localized and presumably superior in terms of speech intelligibility. Because matching the loudness requires higher current in BP than in MP stimulation, previous forward-masking studies show that BP current spread is not consistently narrower across subjects or electrodes within a subject. The present forward-masking measures of current spread differ from those of previous studies by using the same BP probe electrode configuration for both MP and BP masker configurations, and adjusting the current levels of the MP and BP maskers so as to match them in loudness. With this method, the estimate of masker current spread would not be contaminated by differences in probe current spread. Forward masking was studied in four cochlear implant patients, two females and two males, with speech recognition scores higher than 50%; that is, their auditory-nerve survival status was more than adequate to carry out the experiments. The data showed that MP and BP masker configurations produce equivalent masking patterns (and current spreads) in three participants. A fourth participant displayed asymmetrical patterns with enhancement rather than masking in some cases, especially when the probe and masker were at the same location. This study showed equivalent masking patterns for MP and BP maskers when the BP masker current amplitude was increased to match the loudness of the MP masker, and the same BP probe configuration is used with both maskers. This finding could help to explain why cochlear implant users often fail to accrue higher speech intelligibility benefit from BP stimulation.
A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.
1993-01-01
Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
49 CFR 572.154 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... test probe conforming to § 572.155(a) at 5.0 ±0.1m/s (16.5 ±0.3 ft/s) according to the test procedure in paragraph (c) of this section, the peak force, measured by the impact probe in accordance with... longitudinal centerline of the probe coincides with the dummy's midsagittal plane, is centered on the torso 196...
Probes for measuring noise current in an electronic cable
NASA Technical Reports Server (NTRS)
Lundy, C. C.
1974-01-01
Electromagnetic interference in deep-space network receiver is often caused by stray coupling from power lines. These stray signals create potential differences between ground terminals, which leads to excessive noise in receiver circuits. Pair of probes detect and measure noise currents in conductors.
Liu, Cheng; Li, Shiying; Gu, Yanjuan; Xiong, Huahua; Wong, Wing-Tak; Sun, Lei
2018-05-07
Tumor proteases have been recognized as significant regulators in the tumor microenvironment, but the current strategies for in vivo protease imaging have tended to focus on the development of a probe design rather than the investigation of a novel imaging strategy by leveraging the imaging technique and probe. Herein, it is the first report to investigate the ability of multispectral photoacoustic imaging (PAI) to estimate the distribution of protease cleavage sites inside living tumor tissue by using an activatable photoacoustic (PA) probe. The protease MMP-2 is selected as the target. In this probe, gold nanocages (GNCs) with an absorption peak at ~ 800 nm and fluorescent dye molecules with an absorption peak at ~ 680 nm are conjugated via a specific enzymatic peptide substrate. Upon enzymatic activation by MMP-2, the peptide substrate is cleaved and the chromophores are released. Due to the different retention speeds of large GNCs and small dye molecules, the probe alters its intrinsic absorption profile and produces a distinct change in the PA signal. A multispectral PAI technique that can distinguish different chromophores based on intrinsic PA spectral signatures is applied to estimate the signal composition changes and indicate the cleavage interaction sites. Finally, the multispectral PAI technique with the activatable probe is tested in solution, cultured cells, and a subcutaneous tumor model in vivo. Our experiment in solution with enzyme ± inhibitor, cell culture ± inhibitor, and in vivo tumor model with administration of the developed probe ± inhibitor demonstrated the probe was cleaved by the targeted enzyme. Particularly, the in vivo estimation of the cleavage site distribution was validated with the result of ex vivo immunohistochemistry analysis. This novel synergy of the multispectral PAI technique and the activatable probe is a potential strategy for the distribution estimation of tumor protease activity in vivo.
Development of DNA biosensor based on TiO2 nanoparticles
NASA Astrophysics Data System (ADS)
Nadzirah, Sh.; Hashim, U.; Rusop, M.
2018-05-01
A novel technique of DNA hybridization on the TiO2 nanoparticles film was developed by dropping a single droplet of target DNA onto the surface of TiO2 for the study of various concentrations of target DNA. The surface of TiO2 nanoparticle film was functionalized with APTES and covalently immobilized with 1 µM probe DNA on the silanized TiO2 nanoparticles surface. The effect of silanization, immobilization and hybridization were quantitatively measured by the output current signal obtained using a picoammeter. The 1 µM target DNA was found to be the most effective target towards the 1 µM probe DNA as the output current signal was within range; while the output current signal of the 10 µM target DNA was observed to beyond the range of the probe DNA control due to the excessive concentration as compared to the probe DNA. This approach has several advantages such as rapid, simple, low cost, and sensitive current signal during detection of different target DNA concentrations.
Rosetta Langmuir Probe Photoelectron Emission and Solar Ultraviolet Flux at Comet 67P
NASA Astrophysics Data System (ADS)
Johansson, F. L.; Odelstad, E.; Paulsson, J. J.; Harang, S. S.; Eriksson, A. I.; Mannel, T.; Vigren, E.; Edberg, N. J. T.; Miloch, W. J.; Simon Wedlund, C.; Thiemann, E.; Epavier, F.; Andersson, L.
2017-12-01
The Langmuir Probe instrument on Rosetta monitored the photoelectron emission current of the probes during the Rosetta mission at comet 67P/Churyumov-Gerasimenko, in essence acting as a photodiode monitoring the solar ultraviolet radiation at wavelengths below 250 nm. We have used three methods of extracting the photoelectron saturation current from the Langmuir probe measurements. The resulting dataset can be used as an index of the solar far and extreme ultraviolet at the Rosetta spacecraft position, including flares, in wavelengths that are important for photoionisation of the cometary neutral gas. Comparing the photoemission current to data measurements by MAVEN/EUVM and TIMED/SEE, we find good correlation when 67P was at large heliocentric distances early and late in the mission, but up to 50 percent decrease of the expected photoelectron current at perihelion. We discuss possible reasons for the photoemission decrease, including scattering and absorption by nanograins created by disintegration of cometary dust far away from the nucleus.
Ball, B Hunter; DeWitt, Michael R; Knight, Justin B; Hicks, Jason L
2014-09-01
The current study sought to examine the relative contributions of encoding and retrieval processes in accessing contextual information in the absence of item memory using an extralist cuing procedure in which the retrieval cues used to query memory for contextual information were related to the target item but never actually studied. In Experiments 1 and 2, participants studied 1 category member (e.g., onion) from a variety of different categories and at test were presented with an unstudied category label (e.g., vegetable) to probe memory for item and source information. In Experiments 3 and 4, 1 member of unidirectional (e.g., credit or card) or bidirectional (e.g., salt or pepper) associates was studied, whereas the other unstudied member served as a test probe. When recall failed, source information was accessible only when items were processed deeply during encoding (Experiments 1 and 2) and when there was strong forward associative strength between the retrieval cue and target (Experiments 3 and 4). These findings suggest that a retrieval probe diagnostic of semantically related item information reinstantiates information bound in memory during encoding that results in reactivation of associated contextual information, contingent upon sufficient learning of the item itself and the association between the item and its context information.
Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; O'Donnell, Matthew
2014-01-01
Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer. PMID:24737921
Pitch Angle Dependence of Drift Resonant Ions Observed by the Van Allen Probes
NASA Astrophysics Data System (ADS)
Rankin, R.; Wang, C.; Wang, Y.; Zong, Q. G.; Zhou, X.
2017-12-01
Acceleration and modulation of ring current ions by poloidal mode ULF waves is investigated. A simplified MHD model of ULF waves in a dipole magnetic field is presented that includes phase mixing to perpendicular scales determined by the ionospheric Pedersen conductivity. The wave model is combined with a full Lorentz force test particle code to study drift and drift bounce resonance wave-particle interactions. Ion trajectories are traced backward-in-time to an assumed form of the distribution function, and Liouville's method is used to reconstruct the phase space density response (PSD) poloidal mode waves observed by the Van Allen Probes. In spite of its apparent simplicity, simulations using the wave and test particle models are able to explain the acceleration of ions and energy dispersion observed by the Van Allen Probes. The paper focuses on the pitch angle evolution of the initial PSD as it responds to the action of ULF waves. An interesting aspect of the study is the formation of butterfly ion distributions as ions make periodic radial oscillations across L. Ions become trapped in an effective potential well across a limited range of L and follow trajectories that cause them to surf along constant phase fronts. The impications of this new trapping mechanism for both ions and electrons is discussed.
A fast response miniature probe for wet steam flow field measurements
NASA Astrophysics Data System (ADS)
Bosdas, Ilias; Mansour, Michel; Kalfas, Anestis I.; Abhari, Reza S.
2016-12-01
Modern steam turbines require operational flexibility due to renewable energies’ increasing share of the electrical grid. Additionally, the continuous increase in energy demand necessitates efficient design of the steam turbines as well as power output augmentation. The long turbine rotor blades at the machines’ last stages are prone to mechanical vibrations and as a consequence time-resolved experimental data under wet steam conditions are essential for the development of large-scale low-pressure steam turbines. This paper presents a novel fast response miniature heated probe for unsteady wet steam flow field measurements. The probe has a tip diameter of 2.5 mm, and a miniature heater cartridge ensures uncontaminated pressure taps from condensed water. The probe is capable of providing the unsteady flow angles, total and static pressure as well as the flow Mach number. The operating principle and calibration procedure are described in the current work and a detailed uncertainty analysis demonstrates the capability of the new probe to perform accurate flow field measurements under wet steam conditions. In order to exclude any data possibly corrupted by droplets’ impact or evaporation from the heating process, a filtering algorithm was developed and implemented in the post-processing phase of the measured data. In the last part of this paper the probe is used in an experimental steam turbine test facility and measurements are conducted at the inlet and exit of the last stage with an average wetness mass fraction of 8.0%.
Transmit-receive eddy current probes for defect detection and sizing in steam generator tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obrutsky, L.S.; Cecco, V.S.; Sullivan, S.P.
1997-02-01
Inspection of steam generator tubes in aging Nuclear Generating Stations is increasingly important. Defect detection and sizing, especially in defect prone areas such as the tubesheet, support plates and U-bend regions, are required to assess the fitness-for-service of the steam generators. Information about defect morphology is required to address operational integrity issues, i.e., risk of tube rupture, number of tubes at risk, consequential leakage. A major challenge continues to be the detection and sizing of circumferential cracks. Utilities around the world have experienced this type of tube failure. Conventional in-service inspection, performed with eddy current bobbin probes, is ineffectual inmore » detecting circumferential cracks in tubing. It has been demonstrated in CANDU steam generators, with deformation, magnetite and copper deposits that multi-channel probes with transmit-receive eddy current coils are superior to those using surface impedance coils. Transmit-receive probes have strong directional properties, permitting probe optimization according to crack orientation. They are less sensitive to lift-off noise and magnetite deposits and possess good discrimination to internal defects. A single pass C3 array transmit-receive probe developed by AECL can detect and size circumferential stress corrosion cracks as shallow as 40% through-wall. Since its first trial in 1992, it has been used routinely for steam generator in-service inspection of four CANDU plants, preventing unscheduled shutdowns due to leaking steam generator tubes. More recently, a need has surfaced for simultaneous detection of both circumferential and axial cracks. The C5 probe was designed to address this concern. It combines transmit-receive array probe technology for equal sensitivity to axial and circumferential cracks with a bobbin probe for historical reference. This paper will discuss the operating principles of transmit-receive probes, along with inspection results.« less
Design and modeling of a planar probe for power measurements in a capacitive plasma sheath
NASA Astrophysics Data System (ADS)
Gahan, D.; Hopkins, M. B.; Ellingboe, A. R.
2004-09-01
The design and modeling of a planar probe for power measurement in a capacitive RF sheath is described. The probe is to be biased negatively, using a DC power supply, while simultaneously being driven with an RF voltage. A simple model has been developed which describes the voltage, current and impedance from the generator to the probe surface incorporating the transmission line. A conventional method to determine the power through such a probe would be to measure the voltage, current and their phase relationship very close to the probe surface. This can be very difficult to do with much accuracy since the load is almost purely reactive. An alternative method is discussed. The model shows that for certain lengths of transmission line there exists a point on that transmission line where the imaginary impedance goes to zero. If the power is measured at this point where the current and voltage are almost in phase the result should be more accurate. A brief description of the model is given along with some results for its validation. The operation of the power sensor used is also explained.
Quantitative Percussion Diagnostics For Evaluating Bond Integrity Between Composite Laminates
NASA Astrophysics Data System (ADS)
Poveromo, Scott Leonard
Conventional nondestructive testing (NDT) techniques used to detect defects in composites are not able to determine intact bond integrity within a composite structure and are costly to use on large and complex shaped surfaces. To overcome current NDT limitations, a new technology was utilized based on quantitative percussion diagnostics (QPD) to better quantify bond quality in fiber reinforced composite materials. Experimental results indicate that this technology is capable of detecting 'kiss' bonds (very low adhesive shear strength), caused by the application of release agents on the bonding surfaces, between flat composite laminates bonded together with epoxy adhesive. Specifically, the local value of the loss coefficient determined from quantitative percussion testing was found to be significantly greater for a release coated panel compared to that for a well bonded sample. Also, the local value of the probe force or force returned to the probe after impact was observed to be lower for the release coated panels. The increase in loss coefficient and decrease in probe force are thought to be due to greater internal friction during the percussion event for poorly bonded specimens. NDT standards were also fabricated by varying the cure parameters of an epoxy film adhesive. Results from QPD for the variable cure NDT standards and lap shear strength measurements taken of mechanical test specimens were compared and analyzed. Finally, experimental results have been compared to a finite element analysis to understand the visco-elastic behavior of the laminates during percussion testing. This comparison shows how a lower quality bond leads to a reduction in the percussion force by biasing strain in the percussion tested side of the panel.
Investigation of Coatings for Langmuir Probes in an Oxygen-Rich Space Environment
NASA Astrophysics Data System (ADS)
Samaniego, J. I.; Wang, X.; Andersson, L.; Malaspina, D.; Ergun, R.; Horanyi, M.
2017-12-01
The surface properties of the Langmuir probes, such as the one on the MAVEN mission, will change after exposure to upper planetary atmospheres where high concentrations of atomic oxygen and other oxidizing compounds are present. TiN (Titanium Nitride) or DAG (a resin based graphite dispersion) are the most common coatings for current Langmuir probes, yet both of these coatings pose issues when exposed to oxygen-rich space environment. TiN showed reduced surface conductivity while the DAG layers erode with exposure to oxygen. It is known that Iridium (Ir) and Rhenium (Rh) are difficult to oxidize and maintain high conductivity even in their oxidized forms, suggesting them to be good candidates for probe coatings. Oxidation of most metals creates a resistive layer on the surface of the probe that will affect the amount of current being collected at a given voltage during the probe sweep and therefore affect the accuracy of plasma parameters determined by the Langmuir probe (e.g. density, temperature). We present the results of the oxidation effect on the current-voltage curves (I-V curves) and therefore the resulting measured plasma parameters of Ir and Rh wire probes compared with other control metals and coatings (Cu, Ni, TiN) in controlled plasma environments. The oxidation process is performed in an oxygen plasma chamber in which both O+ and O2+ are created and accelerated toward the probes with energies < 10 eV. An argon plasma chamber is used to compare the probe's I-V curves before and after the oxidation process. Our preliminary results indicate that iridium shows the least effect of oxidation on the probe measurements. The second objective of this study is to identify methods that can be used in orbit to clean the surface of Langmuir probes to minimize the effect of exposure to oxidizing compounds.
Comparison of Heat Flux Gages for High Enthalpy Flows - NASA Ames and IRS
NASA Technical Reports Server (NTRS)
Loehle, Stefan; Nawaz, Anuscheh; Herdrich, Georg; Fasoulas, Stefanos; Martinez, Edward; Raiche, George
2016-01-01
This article is a companion to a paper on heat flux measurements as initiated under a Space Act Agreement in 2011. The current focus of this collaboration between the Institute of Space Systems (IRS) of the University of Stuttgart and NASA Ames Research Center is the comparison and refinement of diagnostic measurements. A first experimental campaign to test different heat flux gages in the NASA Interaction Heating Facility (IHF) and the Plasmawindkanaele (PWK) at IRS was established. This paper focuses on the results of the measurements conducted at IRS. The tested gages included a at face and hemispherical probe head, a 4" hemispherical slug calorimeter, a null-point calorimeter from Ames and a null-point calorimeter developed for this purpose at IRS. The Ames null-point calorimeter was unfortunately defective upon arrival. The measured heat fluxes agree fairly well with each other. The reason for discrepancies can be attributed to signal-to-noise levels and the probe geometry.
Probing consciousness with event-related potentials in the vegetative state
Faugeras, F.; Rohaut, B.; Weiss, N.; Bekinschtein, T.A.; Galanaud, D.; Puybasset, L.; Bolgert, F.; Sergent, C.; Cohen, L.; Dehaene, S.
2011-01-01
Objective: Probing consciousness in noncommunicating patients is a major medical and neuroscientific challenge. While standardized and expert behavioral assessment of patients constitutes a mandatory step, this clinical evaluation stage is often difficult and doubtful, and calls for complementary measures which may overcome its inherent limitations. Several functional brain imaging methods are currently being developed within this perspective, including fMRI and cognitive event-related potentials (ERPs). We recently designed an original rule extraction ERP test that is positive only in subjects who are conscious of the long-term regularity of auditory stimuli. Methods: In the present work, we report the results of this test in a population of 22 patients who met clinical criteria for vegetative state. Results: We identified 2 patients showing this neural signature of consciousness. Interestingly, these 2 patients showed unequivocal clinical signs of consciousness within the 3 to 4 days following ERP recording. Conclusions: Taken together, these results strengthen the relevance of bedside neurophysiological tools to improve diagnosis of consciousness in noncommunicating patients. PMID:21593438
Probing noncommutative theories with quantum optical experiments
NASA Astrophysics Data System (ADS)
Dey, Sanjib; Bhat, Anha; Momeni, Davood; Faizal, Mir; Ali, Ahmed Farag; Dey, Tarun Kumar; Rehman, Atikur
2017-11-01
One of the major difficulties of modern science underlies at the unification of general relativity and quantum mechanics. Different approaches towards such theory have been proposed. Noncommutative theories serve as the root of almost all such approaches. However, the identification of the appropriate passage to quantum gravity is suffering from the inadequacy of experimental techniques. It is beyond our ability to test the effects of quantum gravity thorough the available scattering experiments, as it is unattainable to probe such high energy scale at which the effects of quantum gravity appear. Here we propose an elegant alternative scheme to test such theories by detecting the deformations emerging from the noncommutative structures. Our protocol relies on the novelty of an opto-mechanical experimental setup where the information of the noncommutative oscillator is exchanged via the interaction with an optical pulse inside an optical cavity. We also demonstrate that our proposal is within the reach of current technology and, thus, it could uncover a feasible route towards the realization of quantum gravitational phenomena thorough a simple table-top experiment.
A rapid low-cost high-density DNA-based multi-detection test for routine inspection of meat species.
Lin, Chun Chi; Fung, Lai Ling; Chan, Po Kwok; Lee, Cheuk Man; Chow, Kwok Fai; Cheng, Shuk Han
2014-02-01
The increasing occurrence of food frauds suggests that species identification should be part of food authentication. Current molecular-based species identification methods have their own limitations or drawbacks, such as relatively time-consuming experimental steps, expensive equipment and, in particular, these methods cannot identify mixed species in a single experiment. This project proposes an improved method involving PCR amplification of the COI gene and detection of species-specific sequences by hybridisation. Major innovative breakthrough lies in the detection of multiple species, including pork, beef, lamb, horse, cat, dog and mouse, from a mixed sample within a single experiment. The probes used are species-specific either in sole or mixed species samples. As little as 5 pg of DNA template in the PCR is detectable in the proposed method. By designing species-specific probes and adopting reverse dot blot hybridisation and flow-through hybridisation, a low-cost high-density DNA-based multi-detection test suitable for routine inspection of meat species was developed. © 2013.
Evaluation of ion collection area in Faraday probes.
Brown, Daniel L; Gallimore, Alec D
2010-06-01
A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.
Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua
2016-11-04
A fluorimetric Hg 2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the "coffee stains" toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized "coffee stains". On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg 2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of "coffee stains" on test strips may expand the scope of applications of test strips-based "point-of-care" analysis methods or detection devices in the biomedical and environmental fields.
NASA Astrophysics Data System (ADS)
Chen, I.-H.; Horikawa, S.; Xi, J.; Wikle, H. C.; Barbaree, J. M.; Chin, B. A.
2017-05-01
Phage based magneto-elastic (ME) biosensors have been shown to be able to rapidly detect Salmonella in various food systems to serve food pathogen monitoring purposes. In this ME biosensor platform, the free-standing strip-shaped magneto-elastic sensor is the transducer and the phage probe that recognizes Salmonella in food serves as the bio-recognition element. According to Sorokulova et al. at 2005, a developed oligonucleotide probe E2 was reported to have high specificity to Salmonella enterica Typhimurium. In the report, the specificity tests were focused in most of Enterobacterace groups outside of Salmonella family. Here, to understand the specificity of phage E2 to different Salmonella enterica serotypes within Salmonella Family, we further tested the specificity of the phage probe to thirty-two Salmonella serotypes that were present in the major foodborne outbreaks during the past ten years (according to Centers for Disease Control and Prevention). The tests were conducted through an Enzyme linked Immunosorbent Assay (ELISA) format. This assay can mimic probe immobilized conditions on the magnetoelastic biosensor platform and also enable to study the binding specificity of oligonucleotide probes toward different Salmonella while avoiding phage/ sensor lot variations. Test results confirmed that this oligonucleotide probe E2 was high specific to Salmonella Typhimurium cells but showed cross reactivity to Salmonella Tennessee and four other serotypes among the thirty-two tested Salmonella serotypes.
Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis
Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.
1996-10-01
A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.
Outer planet probe engineering model structural tests
NASA Technical Reports Server (NTRS)
Smittkamp, J. A.; Gustin, W. H.; Griffin, M. W.
1977-01-01
A series of proof of concept structural tests was performed on an engineering model of the Outer Planets Atmospheric Entry Probe. The tests consisted of pyrotechnic shock, dynamic and static loadings. The tests partially verified the structural concept.
Kikta, Thomas J.; Mitchell, Ronald D.
1992-01-01
A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet.
Kikta, T.J.; Mitchell, R.D.
1992-11-24
A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet. 4 figs.
Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bousselin, G.; Cavalier, J.; Pautex, J. F.
Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case,more » the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths ({lambda}{sub D}, {rho}{sub ce}) are used.« less
Non-Invasive Blood Perfusion Measurements Using a Combined Temperature and Heat Flux Surface Probe
Ricketts, Patricia L.; Mudaliar, Ashvinikumar V.; Ellis, Brent E.; Pullins, Clay A.; Meyers, Leah A.; Lanz, Otto I.; Scott, Elaine P.; Diller, Thomas E.
2009-01-01
Non-invasive blood perfusion measurement systems have been developed and tested in a phantom tissue and an animal model. The probes use a small sensor with a laminated flat thermocouple to measure the heat transfer and temperature response to an arbitrary thermal event (convective or conductive) imposed on the tissue surface. Blood perfusion and thermal contact resistance are estimated by comparing heat flux data with a mathematical model of the tissue. The perfusion probes were evaluated for repeatability and sensitivity using both a phantom tissue test stand and exposed rat liver tests. Perfusion in the phantom tissue tests was varied by controlling the flow of water into the phantom tissue test section, and the perfusion in the exposed liver tests was varied by temporarily occluding blood flow through the portal vein. The phantom tissue tests indicated that the probes can be used to detect small changes in perfusion (0.005 ml/ml/s). The probes qualitatively tracked the changes in the perfusion of the liver model due to occlusion of the portal vein. PMID:19885372
NASA Astrophysics Data System (ADS)
Kinoshita, M.; Von Herzen, R. P.; Matsubayashi, O.; Fujioka, K.
1998-06-01
During Aug. 13-21, 1994, temperatures and current velocity were simultaneously monitored on the TAG hydrothermal mound. Three `Giant Kelps (GKs)', vertical thermistor arrays of 50 m height, were moored on the periphery of the central black smoker complex (CBC). A `Manatee', multi-monitoring system including current velocity, was deployed 50 m east of CBC. Four `Daibutsu' geothermal probes penetrated the sediment south to west of CBC. Compilation of all data revealed semi-diurnal variations in water temperatures and current velocity, and allowed us to discuss the source of these anomalies. Temperature anomalies of GKs correlate well with current velocity, and are interpreted to be caused by the main plume from CBC that was bent over by the tidal current. We identified two types of asymmetric, periodic temperature variations at Daibutsu Probes 2 and 8, located 20 m to the south of CBC. By comparing temperatures and current velocity, they are attributed to non-buoyant effluents laterally advected by the tidal current. The source of one variation is located east to ESE of the probes, and the source of the other is located to the north. On Aug. 31, a new periodic anomaly emerged on Probe 2 with its amplitude up to 0.8°C. The 6-h offset between the new anomaly and the previous one suggests that the source of the new anomaly lies to the west of Probe 2. The heat flux of these non-buoyant effluents is estimated to range from 30 to 100 kW/m 2, which is of the same order as direct estimates of diffuse flow at the TAG mound. It suggests that a significant amount of diffuse effluent is laterally advected by the prevailing current near the seafloor.
Robust constraint on cosmic textures from the cosmic microwave background.
Feeney, Stephen M; Johnson, Matthew C; Mortlock, Daniel J; Peiris, Hiranya V
2012-06-15
Fluctuations in the cosmic microwave background (CMB) contain information which has been pivotal in establishing the current cosmological model. These data can also be used to test well-motivated additions to this model, such as cosmic textures. Textures are a type of topological defect that can be produced during a cosmological phase transition in the early Universe, and which leave characteristic hot and cold spots in the CMB. We apply bayesian methods to carry out a rigorous test of the texture hypothesis, using full-sky data from the Wilkinson Microwave Anisotropy Probe. We conclude that current data do not warrant augmenting the standard cosmological model with textures. We rule out at 95% confidence models that predict more than 6 detectable cosmic textures on the full sky.
The Role of Cognitive Load in Intentional Forgetting Using the Think/No-Think Task.
Noreen, Saima; de Fockert, Jan W
2017-01-01
We investigated the role of cognitive control in intentional forgetting by manipulating working memory load during the think/no-think task. In two experiments, participants learned a series of cue-target word pairs and were asked to recall the target words associated with some cues or to avoid thinking about the target associated with other cues. In addition to this, participants also performed a modified version of the n-back task which required them to respond to the identity of a single target letter present in the currently presented cue word (n = 0 condition, low working memory load), and in either the previous cue word (n = 1 condition, high working memory load, Experiment 1) or the cue word presented two trials previously (n = 2 condition, high working memory load, Experiment 2). Participants' memory for the target words was subsequently tested using same and novel independent probes. In both experiments it was found that although participants were successful at forgetting on both the same and independent-probe tests in the low working memory load condition, they were only successful at forgetting on the same-probe test in the high working memory load condition. We argue that our findings suggest that the high load working memory task diverted attention from direct suppression and acted as an interference-based strategy. Thus, when cognitive resources are limited participants can switch between the strategies they use to prevent unwanted memories from coming to mind.
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
49 CFR 572.126 - Knees and knee impact test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... procedure in section 572.127(c), the peak resistance force as measured with the test probe mounted... exterior surface. (3) Align the test probe so that throughout its stroke and at contact with the knee it is... probe velocity at the time of contact shall be 2.1 ±0.03 m/s (6.9 # 0.1 ft/s). (6) No suspension...
Effects of Mach number on pitot-probe displacement in a turbulent boundary layer
NASA Technical Reports Server (NTRS)
Allen, J. M.
1974-01-01
Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.
Improved analysis techniques for cylindrical and spherical double probes.
Beal, Brian; Johnson, Lee; Brown, Daniel; Blakely, Joseph; Bromaghim, Daron
2012-07-01
A versatile double Langmuir probe technique has been developed by incorporating analytical fits to Laframboise's numerical results for ion current collection by biased electrodes of various sizes relative to the local electron Debye length. Application of these fits to the double probe circuit has produced a set of coupled equations that express the potential of each electrode relative to the plasma potential as well as the resulting probe current as a function of applied probe voltage. These equations can be readily solved via standard numerical techniques in order to determine electron temperature and plasma density from probe current and voltage measurements. Because this method self-consistently accounts for the effects of sheath expansion, it can be readily applied to plasmas with a wide range of densities and low ion temperature (T(i)/T(e) ≪ 1) without requiring probe dimensions to be asymptotically large or small with respect to the electron Debye length. The presented approach has been successfully applied to experimental measurements obtained in the plume of a low-power Hall thruster, which produced a quasineutral, flowing xenon plasma during operation at 200 W on xenon. The measured plasma densities and electron temperatures were in the range of 1 × 10(12)-1 × 10(17) m(-3) and 0.5-5.0 eV, respectively. The estimated measurement uncertainty is +6%∕-34% in density and +∕-30% in electron temperature.
Experimental Studies of Intent Information on Cockpit Traffic Displays
NASA Technical Reports Server (NTRS)
Barhydt, Richard; Hansman, R. John, Jr.
1997-01-01
Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: No Intent, Rate, Commanded State, and Flight Management System (FMS)-Path. The TCAS Display was used as a baseline and represents the No Intent Level. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An experiment was run on the MIT Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.
Roche, John P; Westenbroek, Ruth; Sorom, Abraham J; Hille, Bertil; Mackie, Ken; Shapiro, Mark S
2002-01-01
KCNQ K+ channels are thought to underlie the M current of neurons. To probe if the KCNQ2 and KCNQ3 subtypes underlie the M current of rat superior cervical ganglia (SCG) neurons and of hippocampus, we raised specific antibodies against them and also used the cysteine-alkylating agent N-ethylmaleimide (NEM) as an additional probe of subunit composition. Tested on tsA-201 (tsA) cells transfected with cloned KCNQ1-5 subunits, our antibodies showed high affinity and selectivity for the appropriate subtype. The antibodies immunostained SCG neurons and hippocampal sections at levels similar to those for channels expressed in tsA cells, indicating that KCNQ2 and KCNQ3 are present in SCG and hippocampal neurons. Some hippocampal regions contained only KCNQ2 or KCNQ3 subunits, suggesting the presence of M currents produced by channels other than KCNQ2/3 heteromultimers. We found that NEM augmented M currents in SCG neurons and KCNQ2/3 currents in tsA cells via strong voltage-independent and modest voltage-dependent actions. Expression of individual KCNQ subunits in tsA cells revealed voltage-independent augmentation of KCNQ2, but not KCNQ1 nor KCNQ3, currents by NEM indicating that this action on SCG M currents likely localizes to KCNQ2. Much of the voltage-independent action is lost after the C242T mutation in KCNQ2. The correspondence of NEM effects on expressed KCNQ2/3 and SCG M currents, along with the antibody labelling, provide further evidence that KCNQ2 and KCNQ3 subunits strongly contribute to the M current of neurons. The site of NEM action may be important for treatment of diseases caused by under-expression of these channels. PMID:12466226
Hot wire needle probe for thermal conductivity detection
Condie, Keith Glenn; Rempe, Joy Lynn; Knudson, Darrell lee; Daw, Joshua Earl; Wilkins, Steven Curtis; Fox, Brandon S.; Heng, Ban
2015-11-10
An apparatus comprising a needle probe comprising a sheath, a heating element, a temperature sensor, and electrical insulation that allows thermal conductivity to be measured in extreme environments, such as in high-temperature irradiation testing. The heating element is contained within the sheath and is electrically conductive. In an embodiment, the heating element is a wire capable of being joule heated when an electrical current is applied. The temperature sensor is contained within the sheath, electrically insulated from the heating element and the sheath. The electrical insulation electrically insulates the sheath, heating element and temperature sensor. The electrical insulation fills the sheath having electrical resistance capable of preventing electrical conduction between the sheath, heating element, and temperature sensor. The control system is connected to the heating element and the temperature sensor.
Design and Calibration of a Flowfield Survey Rake for Inlet Flight Research
NASA Technical Reports Server (NTRS)
Flynn, Darin C.; Ratnayake, Nalin A.; Frederick, Michael
2009-01-01
Flowfield rake was designed to quantify the flowfield for inlet research underneath NASA DFRC s F-15B airplane. Detailed loads and stress analysis performed using CFD and empirical methods to assure structural integrity. Calibration data were generated through wind tunnel testing of the rake. Calibration algorithm was developed to determine the local Mach and flow angularity at each probe. RAGE was flown November, 2008. Data is currently being analyzed.
Design, processing, and testing of LSI arrays for space station
NASA Technical Reports Server (NTRS)
Schneider, W. C.
1974-01-01
At wafer probe, units of the TA6567 circuit, a beam leaded COS/MOS/SOS 256-bit RAM, were demonstrated to be functionally perfect. An aluminum gate current-sense version and a silicon-gate voltage-sense version of this memory were developed. Initial base line data for the beam lead SOS process using the TA5388 circuit show the stability of the dc device characteristics through the beam lead processing.
Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes
NASA Technical Reports Server (NTRS)
Goebel, Dan M.; Jameson, Kristina K.; Watkins, Ron M.; Katz, Ira
2004-01-01
In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.
Flexible Cryogenic Temperature and Liquid-Level Probes
NASA Technical Reports Server (NTRS)
Haberbusch, Mark
2005-01-01
Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.
Flexible Cryogenic Temperature and Liquid-Level Probes
NASA Technical Reports Server (NTRS)
Haberbusch, Mark
2003-01-01
Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.
Flux focusing eddy current probe
NASA Technical Reports Server (NTRS)
Simpson, John W. (Inventor); Clendenin, C. Gerald (Inventor); Fulton, James P. (Inventor); Wincheski, Russell A. (Inventor); Todhunter, Ronald G. (Inventor); Namkung, Min (Inventor); Nath, Shridhar C. (Inventor)
1997-01-01
A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.
Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis
Noble, D.T.; Braymen, S.D.; Anderson, M.S.
1996-10-01
A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point and a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained. 9 figs.
An Experimental Evaluation of the Performance of Two Combination Pitot Pressure Probes
NASA Technical Reports Server (NTRS)
Arend, David J.; Saunders, John D.
2009-01-01
Experimental tests have been completed which recorded the ability of two combination steady state and high response time varying Pitot probe designs to accurately measure steady stagnation pressure at a single location in a flow field. Tests were conducted of double-barreled and coannular Prati probes in a 3.5 in. diameter free jet probe calibration facility from Mach 0.1 to 0.9. Geometric symmetry and pitch (-40 deg to 40 deg) and yaw (0 deg to 40 deg) angle actuation were used to fully evaluate the probes. These tests revealed that the double-barreled configuration induced error in its steady state measurement at zero incidence that increased consistently with jet Mach number to 1.1 percent at Mach 0.9. For all Mach numbers, the double-barreled probe nulled at a pitch angle of approximately 7.0 deg and provided inconsistent measurements when yawed. The double-barreled probe provided adequate measurements via both its steady state and high response tubes (within +/- 0.15 percent accuracy) over unacceptable ranges of biased pitch and inconsistent yaw angles which varied with Mach number. By comparison, the coannular probe provided accurate measurements (at zero incidence) for all jet Mach numbers as well as over a flow angularity range which varied from +/- 26.0 deg at Mach 0.3 deg to +/- 14.0 deg at Mach 0.9. Based on these results, the Prati probe is established as the preferred design. Further experimental tests are recommended to document the frequency response characteristics of the Prati probe.
Addressable Inverter Matrix Tests Integrated-Circuit Wafer
NASA Technical Reports Server (NTRS)
Buehler, Martin G.
1988-01-01
Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.
Oligodeoxynucleotide Probes for Detecting Intact Cells
NASA Technical Reports Server (NTRS)
Rosson, Reinhardt A.; Maurina-Brunker, Julie; Langley, Kim; Pynnonen, Christine M.
2004-01-01
A rapid, sensitive test using chemiluminescent oligodeoxynucleotide probes has been developed for detecting, identifying, and enumerating intact cells. The test is intended especially for use in detecting and enumerating bacteria and yeasts in potable water. As in related tests that have been developed recently for similar purposes, the oligodeoxynucleotide probes used in this test are typically targeted at either singlecopy deoxyribonucleic acid (DNA) genes (such as virulence genes) or the multiple copies (10,000 to 50,000 copies per cell) of 16S ribosomal ribonucleic acids (rRNAs). Some of those tests involve radioisotope or fluorescent labeling of the probes for reporting hybridization of probes to target nucleic acids. Others of those tests involve labeling with enzymes plus the use of chemiluminescent or chromogenic substrates to report hybridization via color or the emission of light, respectively. The present test is of the last-mentioned type. The chemiluminescence in the present test can be detected easily with relatively simple instrumentation. In developing the present test, the hybridization approach was chosen because hybridization techniques are very specific. Hybridization detects stable, inheritable genetic targets within microorganisms. These targets are not dependent on products of gene expression that can vary with growth conditions or physiological states of organisms in test samples. Therefore, unique probes can be designed to detect and identify specific genera or species of bacteria or yeast (in terms of rRNA target sequences) or can be designed to detect and identify virulence genes (genomic target sequences). Because of the inherent specificity of this system, there are few problems of cross-reactivity. Hybridization tests are rapid, but hybridization tests now available commercially lack sensitivity; typically, between 10(exp 6) and 10(exp 7) cells of the target organism are needed to ensure a reliable test. Consequently, the numbers of target bacteria in samples are usually amplified by overnight pre-enrichment growth. These tests are usually performed in laboratories by skilled technicians. The present test was designed to overcome the shortcomings of the commercial hybridization tests. The figure summarizes the major steps of the test. It is important to emphasize that the hybridization process used in this test differs from that of other hybridization tests in that it does not extract target nucleic acids. This process is based on intact-cell hybridization (so-called in situ hybridization ), wherein the intact cells act as immobilizing agents. The cells are identified and enumerated by measuring the chemiluminescence emitted from alkaline phosphatase-probe (AP-probe) hybridization; the chemiluminescence is detected or measured by use of photographic film or a luminometer, respectively.
Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua
2016-01-01
A fluorimetric Hg2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the “coffee stains” toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized “coffee stains”. On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of “coffee stains” on test strips may expand the scope of applications of test strips-based “point-of-care” analysis methods or detection devices in the biomedical and environmental fields. PMID:27812040
Barker, Timothy Hugh; Howarth, Gordon Stanley; Whittaker, Alexandra Louise
2018-01-01
Extinction of learning is a common, yet under-reported limitation of judgment bias testing methods Repeated exposure to the ambiguous probe of a judgment bias paradigm encourages the animal to cease display of the required behaviours. However, there remains a need to repeatedly test animals to achieve statistical power. A delicate balance therefore needs to be struck between over- and under-exposure of the animals to the test conditions. This study presents the data of rats, a common animal subject of judgment bias testing. Rats were exposed to the ambiguous probe of a common, active-choice judgment bias test for 11 consecutive days. There was a significant increase in the latency to respond to the ambiguous probe following day 8, with no significant increase experienced for either the positive or less-positive probes. Following day 8 there was a significant increase in both optimistic and pessimistic latencies in response to the ambiguous probe. Therefore, repeated exposure to the ambiguous probe caused an increased latency in response even though optimistic interpretations were recorded. This implies that the use of response latency alone as a measure in judgment bias testing can falsely identify pessimism. Researchers should modify experimental design to include both choice and latency measures. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Fluorescent probes for lipid rafts: from model membranes to living cells.
Klymchenko, Andrey S; Kreder, Rémy
2014-01-16
Membrane microdomains (rafts) remain one of the controversial issues in biophysics. Fluorescent molecular probes, which make these lipid nanostructures visible through optical techniques, are one of the tools currently used to study lipid rafts. The most common are lipophilic fluorescent probes that partition specifically into liquid ordered or liquid disordered phase. Their partition depends on the lipid composition of a given phase, which complicates their use in cellular membranes. A second class of probes is based on environment-sensitive dyes, which partition into both phases, but stain them by different fluorescence color, intensity, or lifetime. These probes can directly address the properties of each separate phase, but their cellular applications are still limited. The present review focuses on summarizing the current state in the field of developing and applying fluorescent molecular probes to study lipid rafts. We highlight an urgent need to develop new probes, specifically adapted for cell plasma membranes and compatible with modern fluorescence microscopy techniques to push the understanding of membrane microdomains forward. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Lagen, Nicholas T.; Seiner, John M.
1990-01-01
The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.
Eddy current inspection tool. [Patent application
Petrini, R.R.; Van Lue, D.F.
1980-10-29
A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment with a probe coil, and associated coaxial coil cable, oil energizing means, and circuit means responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube of a fiberoptic scope. The scope is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator for generating audible signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signalling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level.
Emission Spectroscopic Measurements with an Optical Probe in the NASA Ames IHF Arc Jet Facility
NASA Technical Reports Server (NTRS)
Winter, Michael; Prabhu, Dinesh K.; Raiche, George A.; Terrazas-Salinas, Imelda; Hui, Frank C. L.
2011-01-01
An optical probe was designed to measure radiation (from inside the arc heater) incident on a test sample immersed in the arc-heated stream. Currently, only crude estimates are available for this incident radiation. Unlike efforts of the past, where the probe line of sight was inclined to the nozzle centerline, the present development focuses on having the probe line of sight coincide with the nozzle centerline. A fiber-coupled spectrometer was used to measure the spectral distribution of incident radiation in the wavelength range of 225 to 900 nm. The radiation heat flux in this wavelength range was determined by integration of measured emission spectral intensity calibrated to incident irradiance from an integrating sphere. Two arc-heater conditions, corresponding to stream bulk enthalpy levels of 12 and 22 MJ/kg, were investigated in the 13-inch diameter nozzle of the Interaction Heating Facility at NASA Ames Research Center. With the probe placed at a distance of 10 inches from the nozzle exit plane, total radiative heat fluxes were measured to be 3.3 and 8.4 W/sq cm for the 12 and 22 MJ/kg conditions, respectively. About 17% of these radiative fluxes were due to bound-bound radiation from atoms and molecules, while the remaining 83% could be attributed to continua (bound-free and/or free-free). A comparison with spectral simulation based on CFD solutions for the arc-heater flow field and with spectroscopic measurements in the plenum region indicates that more than 95% of the measured radiation is generated in the arc region. The total radiative heat flux from the line radiation could increase by a factor of two through contributions from wavelengths outside the measured range, i.e., from the vacuum ultraviolet (wavelengths less than 225 nm) and the infrared (wavelengths greater than 900 nm). An extrapolation of the continuum radiation to these two wavelength regions was not attempted. In the tested configuration, the measured radiative heat flux accounts for only about 1.4% of the nominal heat flux on a flat face model and therefore is considered negligible. In the 6-inch diameter nozzle, on account of shorter path lengths, the radiation heat flux could be significant. Therefore, future tests in the 6-inch nozzle will have radiometers in addition to the optical probe.
Neal, Robert E; Kavnoudias, Helen; Thomson, Kenneth R
2015-06-01
Irreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators. We describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator. Accuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues. This system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents-sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2013 CFR
2013-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2014 CFR
2014-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
Code of Federal Regulations, 2012 CFR
2012-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2013 CFR
2013-10-01
... of the forward edge of the seat. (3) Align the test probe specified in § 572.11(a) so that at impact...) Impact the knee with the test probe moving horizontally and parallel to the midsagittal plane at the specified velocity. (5) Guide the probe during impact so that it moves with no significant lateral, vertical...
Code of Federal Regulations, 2012 CFR
2012-10-01
... impact, is impacted by a test probe conforming to § 572.44(a) at 14 fps in accordance with paragraph (b... of the test probe at the lateral side of the chest at the intersection of the centerlines of the... side of the vehicle. The probe's centerline is perpendicular to thorax's midsagittal plane. (3) Align...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.134 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... completely assembled dummy (drawing 880105-000) is impacted by a test probe conforming to section 572.137(a...). Within this specified compression corridor, the peak force, measured by the impact probe as defined in... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
49 CFR 572.174 - Thorax assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... assembled dummy (drawing 420-0000) (incorporated by reference, see § 572.170) is impacted by a test probe... this specified compression corridor, the peak force, measured by the impact probe as defined in section... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...
NASA Technical Reports Server (NTRS)
Bobbitt, Percy J.; Maglieri, Domenic J.; Banks, Daniel W.; Fuchs, Aaron W.
2011-01-01
Wedge and conical shaped probes for the measurement of free-stream flow quantities at supersonic speeds have been tested in both wind tunnel and flight. These probes have improved capabilities over similar ones used in the past. Through the use of miniature pressure sensors, that are located inside the probes, they are able to provide instantaneous measurements of a time-varying environment. Detailed herein are the results of the tests in NASA Langley Researcher Center s Unitary Plan Wind Tunnel (UPWT) at Mach numbers of 1.6, 1.8 and 2.0, as well as flight tests carried out at the NASA Dryden Flight Research Center (DFRC) on its F-15 aircraft up to Mach numbers of 1.9. In the flight tests the probes were attached to a fixture on the underside of the F-15 fuselage. Problems controlling the velocity of the flow through the conical probe, required for accurate temperature measurements, are noted, as well as some calibration problems of the miniature pressure sensors that impact the accuracy of the measurements.
Waveguide Calibrator for Multi-Element Probe Calibration
NASA Technical Reports Server (NTRS)
Sommerfeldt, Scott D.; Blotter, Jonathan D.
2007-01-01
A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The flexible nature of the tubes allows them to be positioned so that each tube terminates at one of the microphones of the energy density probe, which is mounted in the acrylic structure, or the calibrated reference microphone. Tests performed verify that the pressure did not vary due to bends in the tubes. The results of these tests indicate that the average sound pressure level in the tubes varied by only 0.03 dB as the tubes were bent to various angles. The current calibrator design is effective up to a frequency of approximately 4.5 kHz. This upper design frequency is largely due to the diameter of the plane-wave tubes.
Estimation of plasma ion saturation current and reduced tip arcing using Langmuir probe harmonics.
Boedo, J A; Rudakov, D L
2017-03-01
We present a method to calculate the ion saturation current, I sat , for Langmuir probes at high frequency (>100 kHz) using the harmonics technique and we compare that to a direct measurement of I sat . It is noted that the I sat estimation can be made directly by the ratio of harmonic amplitudes, without explicitly calculating T e . We also demonstrate that since the probe tips using the harmonic method are oscillating near the floating potential, drawing little power, this method reduces tip heating and arcing and allows plasma density measurements at a plasma power flux that would cause continuously biased tips to arc. A multi-probe array is used, with two spatially separated tips employing the harmonics technique and measuring the amplitude of at least two harmonics per tip. A third tip, located between the other two, measures the ion saturation current directly. We compare the measured and calculated ion saturation currents for a variety of plasma conditions and demonstrate the validity of the technique and its use in reducing arcs.
Estimation of plasma ion saturation current and reduced tip arcing using Langmuir probe harmonics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boedo, J. A.; Rudakov, D. L.
Here we present a method to calculate the ion saturation current, I sat, for Langmuir probes at high frequency (>100 kHz) using the harmonics technique and we compare that to a direct measurement of I sat. It is noted that the Isat estimation can be made directly by the ratio of harmonic amplitudes, without explicitly calculating T e. We also demonstrate that since the probe tips using the harmonic method are oscillating near the floating potential, drawing little power, this method reduces tip heating and arcing and allows plasma density measurements at a plasma power flux that would cause continuouslymore » biased tips to arc. A multi-probe array is used, with two spatially separated tips employing the harmonics technique and measuring the amplitude of at least two harmonics per tip. A third tip, located between the other two, measures the ion saturation current directly. We compare the measured and calculated ion saturation currents for a variety of plasma conditions and demonstrate the validity of the technique and it’s use in reducing arcs.« less
Estimation of plasma ion saturation current and reduced tip arcing using Langmuir probe harmonics
Boedo, J. A.; Rudakov, D. L.
2017-03-20
Here we present a method to calculate the ion saturation current, I sat, for Langmuir probes at high frequency (>100 kHz) using the harmonics technique and we compare that to a direct measurement of I sat. It is noted that the Isat estimation can be made directly by the ratio of harmonic amplitudes, without explicitly calculating T e. We also demonstrate that since the probe tips using the harmonic method are oscillating near the floating potential, drawing little power, this method reduces tip heating and arcing and allows plasma density measurements at a plasma power flux that would cause continuouslymore » biased tips to arc. A multi-probe array is used, with two spatially separated tips employing the harmonics technique and measuring the amplitude of at least two harmonics per tip. A third tip, located between the other two, measures the ion saturation current directly. We compare the measured and calculated ion saturation currents for a variety of plasma conditions and demonstrate the validity of the technique and it’s use in reducing arcs.« less
NASA Technical Reports Server (NTRS)
Bobbitt, Percy J.; Maglieri, Domenic J.; Banks, Daniel W.; Frederick, Michael A.; Fuchs, Aaron W.
2012-01-01
The results of supersonic wind-tunnel tests on three probes at nominal Mach numbers of 1.6, 1.8 and 2.0 and flight tests on two of these probes up to a Mach number of 1.9 are described. One probe is an 8 deg. half-angle wedge with two total-pressure measurements and one static. The second, a conical probe, is a cylinder that has a 15 deg., semi-angle cone tip with one total-pressure orifice at the apex and four static-pressure orifices on the surface of the cone, 90 deg. apart, and about two-thirds of the distance from the cone apex to the base of the cone. The third is a 2 deg. semi-angle cone that has two static ports located 180 deg. apart about 1.5 inches behind the apex of the cone. The latter probe was included since it has been the "probe of choice" for wind-tunnel flow-field pressure measurements (or one similar to it) for the past half-century. The wedge and 15 deg. conical probes used in these tests were designed for flight diagnostic measurements for flight Mach numbers down to 1.35 and 1.15 respectively, and have improved capabilities over earlier probes of similar shape. The 15. conical probe also has a temperature sensor that is located inside the cylindrical part of the probe that is exposed to free-stream flow through an annulus at the apex of the cone. It enables the determination of free-stream temperature, density, speed of sound, and velocity, in addition to free-stream pressure, Mach number, angle of attack and angle of sideslip. With the time-varying velocity, acceleration can be calculated. Wind-tunnel tests of the two probes were made in NASA Langley Research Center fs Unitary Plan Wind Tunnel (UPWT) at Mach numbers of 1.6, 1.8, and 2.0. Flight tests were carried out at the NASA Dryden Flight Research Center (DFRC) on its F-15B aircraft up to Mach numbers of 1.9. The probes were attached to a fixture, referred to as the Centerline Instrumented Pylon (CLIP), under the fuselage of the aircraft. Problems controlling the velocity of the flow through the conical probe required for accurate temperature measurements are noted, as well as some calibration problems of the miniature pressure sensors that required a re-calculation of the flow variables. Data are presented for angle of attack, pressure and Mach number obtained in the wind tunnel and in flight. In the wind tunnel some transient data were obtained by translating the probes through the shock flow field created by a bump on the wind-tunnel wall.
Eddy Current Sensing of Torque in Rotating Shafts
NASA Astrophysics Data System (ADS)
Varonis, Orestes J.; Ida, Nathan
2013-12-01
The noncontact torque sensing in machine shafts is addressed based on the stress induced in a press-fitted magnetoelastic sleeve on the shaft and eddy current sensing of the changes of electrical conductivity and magnetic permeability due to the presence of stress. The eddy current probe uses dual drive, dual sensing coils whose purpose is increased sensitivity to torque and decreased sensitivity to variations in distance between probe and shaft (liftoff). A mechanism of keeping the distance constant is also employed. Both the probe and the magnetoelastic sleeve are evaluated for performance using a standard eddy current instrument. An eddy current instrument is also used to drive the coils and analyze the torque data. The method and sensor described are general and adaptable to a variety of applications. The sensor is suitable for static and rotating shafts, is independent of shaft diameter and operational over a large range of torques. The torque sensor uses a differential eddy current measurement resulting in cancellation of common mode effects including temperature and vibrations.
Real time Faraday spectrometer
Smith, Jr., Tommy E.; Struve, Kenneth W.; Colella, Nicholas J.
1991-01-01
This invention uses a dipole magnet to bend the path of a charged particle beam. As the deflected particles exit the magnet, they are spatially dispersed in the bend-plane of the magnet according to their respective momenta and pass to a plurality of chambers having Faraday probes positioned therein. Both the current and energy distribution of the particles is then determined by the non-intersecting Faraday probes located along the chambers. The Faraday probes are magnetically isolated from each other by thin metal walls of the chambers, effectively providing real time current-versus-energy particle measurements.
Analysis of ProSEDS Test of Bare-Tether Collection
NASA Technical Reports Server (NTRS)
Sanmartin, J. R.; Lorenzini, E. C.; Estes, R. D.; Charro, M.; Cosmo, M. L.
2003-01-01
NASA's tether experiment ProSEDS will be placed in orbit on board a Delta-II rocket to test bare-tether electron collection, deorbiting of the rocket second stage, and the system dynamic stability. ProSEDS performance will vary because ambient conditions change along the orbit and tether-circuit bulk elements at the cathodic end follow the step-by-step sequence for the current cycles of operating modes (open-circuit, shunt and resistor modes for primary cycles; shunt and battery modes for secondary cycles). In this work we discuss expected ProSEDS values of the ratio L,/L*, which jointly with cathodic bulk elements determines bias and current tether profiles; L, is tether length, and L* (changing with tether temperature and ionospheric plasma density and magnetic field) is a characteristic length gauging ohmic versus baretether collection impedances. We discuss how to test bare-tether electron collection during primary cycles, using probe measurements of plasma density, measurements of cathodic current in resistor and shunt modes, and an estimate of tether temperature based on ProSEDS orbital position at the particular cycle concerned. We discuss how a temperature misestimate might occasionally affect the test of bare-tether collection, and how introducing the battery mode in some primary cycles, for an additional current measurement, could obviate the need of a temperature estimate. We also show how to test bare-tether collection by estimating orbit-decay rate from measurements of cathodic current for the shunt and battery modes of secondary cycles.
NASA Astrophysics Data System (ADS)
Donovan, D.; Nygren, R.; Buchenauer, D.; Watkins, J.; Rudakov, D.; Leonard, A.; Wong, C. P. C.; Makowski, M.
2014-04-01
Experimental results are presented from the three-Langmuir probe (LP) diagnostic head of the divertor material evaluation system (DiMES) on DIII-D that confirm the size of the projected current collection area of the LPs, which is essential for properly measuring ion saturation current density (Jsat) and the sheath power transmission factor (SPTF). Also using the 3-LP DiMES head, the hypothesis that collisional effects on plasma density occurring in the magnetic sheath of the tile are responsible for a lower than expected SPTF is tested and deemed not to have a significant impact on the SPTF. Three-dimensional thermal modeling of wall tiles is presented that accounts for lateral heat conduction, temperature dependence of tile material properties and radiative heat loss from the tile surface. This modeling was developed to be used in the analysis of temperature profiles of the divertor embedded thermocouple (TC) array to obtain more accurate interpretations of TC temperature profiles to infer divertor surface heat flux than have previously been accomplished using more basic one-dimensional methods.
Electroanalytical study of proflavine intercalation in 5-methyl or inosine-containing amplicons.
Alexiadou, Despina K; Ioannou, Andrea K; Kouidou-Andreou, Sofia A; Voulgaropoulos, Anastasios N; Girousi, Stella Th
2008-10-01
Amplicons corresponding to the GC-rich p53 exon 5 and its analogues, synthesized by substituting 60% of cytosine by 5-methyl-cytosine, or 60% of guanosine by inosine and GC-poor p53 exon 6 were synthesized and investigated electrochemically, in the presence and absence of proflavine, by differential pulse voltammetry (DPV). Incorporation of base analogues and the thermal stability of the resulting amplicons were tested in the presence of a fluorescent probe (Sybr-Green). Peak current at 1.0 V was lower for methylated than for unmethylated PCR amplicons and was similarly affected by proflavine intercalation. In contrast, considerable peak current differences were observed in the presence of proflavine for unmodified exon 5 v.s. exon 6 or inosine-containing amplicons. Thermal analysis verified the expected shifts in melting temperature (T (m)) due to the base analogue incorporation and GC-content variations. In conclusion, methylated and unmethylated PCR amplicons could be distinguished in model DNA systems using differential pulse voltammetry (DPV) and use of proflavine could serve as an electrochemical probe for identifying different DNA conformations.
Wimpee, C F; Nadeau, T L; Nealson, K H
1991-01-01
By using two highly conserved region of the luxA gene as primers, polymerase chain reaction amplification methods were used to prepare species-specific probes against the luciferase gene from four major groups of marine luminous bacteria. Laboratory studies with test strains indicated that three of the four probes cross-reacted with themselves and with one or more of the other species at low stringencies but were specific for members of their own species at high stringencies. The fourth probe, generated from Vibrio harveyi DNA, cross-reacted with DNAs from two closely related species, V. orientalis and V. vulnificus. When nonluminous cultures were tested with the species-specific probes, no false-positive results were observed, even at low stringencies. Two field isolates were correctly identified as Photobacterium phosphoreum by using the species-specific hybridization probes at high stringency. A mixed probe (four different hybridization probes) used at low stringency gave positive results with all of the luminous bacteria tested, including the terrestrial species, Xenorhabdus luminescens, and the taxonomically distinct marine bacterial species Shewanella hanedai; minimal cross-hybridization with these species was seen at higher stringencies. Images PMID:1854194
Modeling of current characteristics of segmented Langmuir probe on DEMETER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imtiaz, Nadia; Marchand, Richard; Lebreton, Jean-Pierre
We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numericallymore » with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.« less
The promise and peril of chemical probes
Arrowsmith, Cheryl H; Audia, James E; Austin, Christopher; Baell, Jonathan; Bennett, Jonathan; Blagg, Julian; Bountra, Chas; Brennan, Paul E; Brown, Peter J; Bunnage, Mark E; Buser-Doepner, Carolyn; Campbell, Robert M; Carter, Adrian J; Cohen, Philip; Copeland, Robert A; Cravatt, Ben; Dahlin, Jayme L; Dhanak, Dashyant; Frederiksen, Mathias; Frye, Stephen V; Gray, Nathanael; Grimshaw, Charles E; Hepworth, David; Howe, Trevor; Huber, Kilian V M; Jin, Jian; Knapp, Stefan; Kotz, Joanne D; Kruger, Ryan G; Lowe, Derek; Mader, Mary M; Marsden, Brian; Mueller-Fahrnow, Anke; Müller, Susanne; O'Hagan, Ronan C; Overington, John P; Owen, Dafydd R; Rosenberg, Saul H; Ross, Ruth; Roth, Bryan; Schapira, Matthieu; Schreiber, Stuart L; Shoichet, Brian; Sundström, Michael; Superti-Furga, Giulio; Taunton, Jack; Toledo-Sherman, Leticia; Walpole, Chris; Walters, Michael A; Willson, Timothy M; Workman, Paul; Young, Robert N; Zuercher, William J
2016-01-01
Chemical probes are powerful reagents with increasing impacts on biomedical research. However, probes of poor quality or that are used incorrectly generate misleading results. To help address these shortcomings, we will create a community-driven wiki resource to improve quality and convey current best practice. PMID:26196764
Hui, Ling; Geiersbach, Katherine B; Downs-Kelly, Erinn; Gulbahce, H Evin
2017-02-01
-In 2013 the American Society of Clinical Oncology and College of American Pathologists updated the HER2 guidelines and changed the equivocal category for HER2 in situ hybridization testing to an average HER2 copy number of 4.0 to 5.9 with a HER2:CEP17 ratio of less than 2.0 and proposed retesting, with an option of using another control probe to avoid false-negative results. RAI1, located at band position 17p11.2, is a popular alternate probe locus for retesting equivocal changes. -To review experience with the RAI1 alternate probe in HER2 fluorescence in situ hybridization equivocal breast cancers. -Primary and metastatic breast cancers with equivocal HER2 fluorescence in situ hybridization, retested with an alternate (RAI1) probe, were identified. HER2, RAI1, and CEP17 copy numbers, HER2 to control probe ratios, and genetic heterogeneity were recorded. Hematoxylin-eosin-stained slides were reviewed for type and grade of cancer. -Of 876 cases tested with CEP17 as the reference probe, 97 (11.1%) had equivocal HER2 fluorescence in situ hybridization results. Additional testing with the RAI1 probe classified 39.2% cases (38 of 97) as amplified with a HER2:RAI1 ratio ranging from 2.0 to 3.2 (mean, 2.37); 3.1% (3 of 97) were still unclassifiable because of a deletion of RAI1. -RAI1 identified close to 40% of original HER2 fluorescence in situ hybridization equivocal cases as amplified, making these patients eligible for targeted therapies. It is not known whether guidelines for US Food and Drug Administration-approved probes can be extrapolated to alternate probes when an alternate control probe shows losses or gains. Because of the lack of guidelines for reporting HER2 status with alternate probes, laboratories face challenges in interpreting results.
Facilitation and refractoriness of the electrically evoked compound action potential.
Hey, Matthias; Müller-Deile, Joachim; Hessel, Horst; Killian, Matthijs
2017-11-01
In this study we aim to resolve the contributions of facilitation and refractoriness at very short pulse intervals. Measurements of the refractory properties of the electrically evoked compound action potential (ECAP) of the auditory nerve in cochlear implant (CI) users at inter pulse intervals below 300 μs are influenced by facilitation and recovery effects. ECAPs were recorded using masker pulses with a wide range of current levels relative to the probe pulse levels, for three suprathreshold probe levels and pulse intervals from 13 to 200 μs. Evoked potentials were measured for 21 CI patients by using the masked response extraction artifact cancellation procedure. During analysis of the measurements the stimulation current was not used as absolute value, but in relation to the patient's individual ECAP threshold. This enabled a more general approach to describe facilitation as a probe level independent effect. Maximum facilitation was found for all tested inter pulse intervals at masker levels near patient's individual ECAP threshold, independent from probe level. For short inter pulse intervals an increased N 1 P 1 amplitude was measured for subthreshold masker levels down to 120 CL below patient's individual ECAP threshold in contrast to the recreated state. ECAPs recorded with inter pulse intervals up to 200 μs are influenced by facilitation and recovery. Facilitation effects are most pronounced for masker levels at or below ECAP threshold, while recovery effects increase with higher masker levels above ECAP threshold. The local maximum of the ECAP amplitude for masker levels around ECAP threshold can be explained by the mutual influence of maximum facilitation and minimal refractoriness. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.