Sample records for curved position sensitive

  1. Curved position-sensitive detector for X-ray crystallography

    NASA Astrophysics Data System (ADS)

    Izumi, T.

    1980-11-01

    A new curved position-sensitive proportional detector has been constructed for X-ray crystallography. A very hard steel wire 0.2 mm in diameter was used as a single anode wire. It was bent to a radius of 6.5 cm and was suspended elastically in a wide 160° 2θ angular aperture. An amplifier and ADC-per-cathode strip system was made in order to encode the position. The spatial resolution is better than 0.37 mm (fwhm) along the curved anode wire, and this value corresponds to an angular resolution of 0.28° in 2θ. It is shown that a thick hard anode wire is quite suitable for use as a curved position-sensitive detector.

  2. ROC-ing along: Evaluation and interpretation of receiver operating characteristic curves.

    PubMed

    Carter, Jane V; Pan, Jianmin; Rai, Shesh N; Galandiuk, Susan

    2016-06-01

    It is vital for clinicians to understand and interpret correctly medical statistics as used in clinical studies. In this review, we address current issues and focus on delivering a simple, yet comprehensive, explanation of common research methodology involving receiver operating characteristic (ROC) curves. ROC curves are used most commonly in medicine as a means of evaluating diagnostic tests. Sample data from a plasma test for the diagnosis of colorectal cancer were used to generate a prediction model. These are actual, unpublished data that have been used to describe the calculation of sensitivity, specificity, positive predictive and negative predictive values, and accuracy. The ROC curves were generated to determine the accuracy of this plasma test. These curves are generated by plotting the sensitivity (true-positive rate) on the y axis and 1 - specificity (false-positive rate) on the x axis. Curves that approach closest to the coordinate (x = 0, y = 1) are more highly predictive, whereas ROC curves that lie close to the line of equality indicate that the result is no better than that obtained by chance. The optimum sensitivity and specificity can be determined from the graph as the point where the minimum distance line crosses the ROC curve. This point corresponds to the Youden index (J), a function of sensitivity and specificity used commonly to rate diagnostic tests. The area under the curve is used to quantify the overall ability of a test to discriminate between 2 outcomes. By following these simple guidelines, interpretation of ROC curves will be less difficult and they can then be interpreted more reliably when writing, reviewing, or analyzing scientific papers. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Cervical VEMP threshold response curve in the identification of Ménière's disease.

    PubMed

    Zhu, Yi; McPherson, James; Beatty, Charles; Driscoll, Colin; Neff, Brian; Eggers, Scott; Shepard, Neil T

    2014-03-01

    To investigate the sensitivity/specificity of a shift upward in the most sensitive frequency of the cervical vestibular evoked myogenic potential (cVEMP) threshold-response curve in the identification of Ménière's disease (MD). A secondary purpose was to investigate the clinical characteristics that had an impact on the sensitivity/specificity and to adjust the criteria for a positive shift upward in the cVEMP curve to maximize performance of the test. A retrospective review of patients diagnosed with MD and those without MD. Two hundred ninety-four patients met the inclusion criteria of symptom complaints of spontaneous events of vertigo and a full vestibular and balance evaluation with cVEMP threshold-response curve testing. Two hundred six of these patients were diagnosed with MD, and 88 patients were determined to be non-MD. Review of the patients' medical records was used to extract data on the results of the cVEMP curve, age, gender, duration from time of onset of spontaneous events, pure tone average from hearing test, and water caloric asymmetry. Student's t-test, χ² test, receiver operating characteristic (ROC) curve with area under the curve (AUC), Pearson correlation coefficient, and sensitivity/specificity from 2 × 2 tables were all used in the analysis. Basic sensitivity/specificity for a shift upward in the most sensitive frequency to 1000 Hz in the cVEMP threshold-response curve was 0.47/0.64 respectively. Clinical characteristics that were found to have a significant impact on the sensitivity/specificity were age equal to or above 60 yr and a caloric asymmetry ≥25%. Various combinations of age and caloric with the requirement of a shift upward in the cVEMP curve most sensitive frequency to 1000 Hz resulted in significant but modest improvements in sensitivity/specificity. However, the overall performance was not shown acceptable for routine clinical use with maximum sensitivity at 0.73. Therefore, placing an emphasis on specificity over sensitivity results showed specificity of 0.95 for those under 60 yr and 0.90 for those 60 yr of age or older with sensitivity at 0.20, but only in the context of a ≥25% caloric asymmetry. We recommend the use of the shift upward to 1000 Hz with a caloric asymmetry as the clinical protocol to maximize the use of the cVEMP threshold-response curve for assistance in the identification of MD, in the context of a ≥25% caloric asymmetry. This implies that if the test is negative no interpretation of identification of MD can be made. If the test is positive the results can be used to increase the argument for MD since the probability of the result being a false positive is only 5-10%. American Academy of Audiology.

  4. High speed curved position sensitive detector

    DOEpatents

    Hendricks, Robert W.; Wilson, Jack W.

    1989-01-01

    A high speed curved position sensitive porportional counter detector for use in x-ray diffraction, the detection of 5-20 keV photons and the like. The detector employs a planar anode assembly of a plurality of parallel metallic wires. This anode assembly is supported between two cathode planes, with at least one of these cathode planes having a serpentine resistive path in the form of a meander having legs generally perpendicular to the anode wires. This meander is produced by special microelectronic fabrication techniques whereby the meander "wire" fans outwardly at the cathode ends to produce the curved aspect of the detector, and the legs of the meander are small in cross-section and very closely spaced whereby a spatial resolution of about 50 .mu.m can be achieved. All of the other performance characteristics are about as good or better than conventional position sensitive proportional counter type detectors. Count rates of up to 40,000 counts per second with 0.5 .mu.s shaping time constants are achieved.

  5. Translation, adaptation, and validation of the Sunderland Scale and the Cubbin & Jackson Revised Scale in Portuguese

    PubMed Central

    Sousa, Bruno

    2013-01-01

    Objective To translate into Portuguese and evaluate the measuring properties of the Sunderland Scale and the Cubbin & Jackson Revised Scale, which are instruments for evaluating the risk of developing pressure ulcers during intensive care. Methods This study included the process of translation and adaptation of the scales to the Portuguese language, as well as the validation of these tools. To assess the reliability, Cronbach alpha values of 0.702 to 0.708 were identified for the Sunderland Scale and the Cubbin & Jackson Revised Scale, respectively. The validation criteria (predictive) were performed comparatively with the Braden Scale (gold standard), and the main measurements evaluated were sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve, which were calculated based on cutoff points. Results The Sunderland Scale exhibited 60% sensitivity, 86.7% specificity, 47.4% positive predictive value, 91.5% negative predictive value, and 0.86 for the area under the curve. The Cubbin & Jackson Revised Scale exhibited 73.3% sensitivity, 86.7% specificity, 52.4% positive predictive value, 94.2% negative predictive value, and 0.91 for the area under the curve. The Braden scale exhibited 100% sensitivity, 5.3% specificity, 17.4% positive predictive value, 100% negative predictive value, and 0.72 for the area under the curve. Conclusions Both tools demonstrated reliability and validity for this sample. The Cubbin & Jackson Revised Scale yielded better predictive values for the development of pressure ulcers during intensive care. PMID:23917975

  6. Performance of the dipstick screening test as a predictor of negative urine culture

    PubMed Central

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086

  7. Characterization of bending EAP beams

    NASA Technical Reports Server (NTRS)

    Bao, Xiaoqi; Bar-Cohen, Yoseph; Chang, Zensheu; Sherrit, Stewart

    2004-01-01

    Electroactive polymers are attractive actuation materials because of their large deformation, flexibility, and lightweight. A CCD camera system was constructed to record the curved shapes of bending during the activation of EAP films and image-processing software was developed to digitize the bending curves. A computer program was developed to solve the invese problem of cantilever EAP beams with tip position limiter. using the developed program and acquired curves without tip position limiter as well as the corresponding tip force, the EAP material properties of voltage-strain sensitivity and Young's modulus were determined.

  8. Diagnostic value of secreted frizzled-related protein 2 gene promoter hypermethylation in stool for colorectal cancer: A meta-analysis.

    PubMed

    Zhou, Zhiran; Zhang, Huitian; Lei, Yunxia

    2016-10-01

    To evaluate the diagnostic value of secreted frizzled-related protein 2 (SFRP2) gene promoter hypermethylation in stool for colorectal cancer (CRC). Open published diagnostic study of SFRP2 gene promoter hypermethylation in stool for CRC detection was electronic searched in the databases of PubMed, EMBASE, Cochrane Library, Web of Science, and China National Knowledge Infrastructure. The data of true positive, false positive false negative, and true negative identified by stool SFRP2 gene hypermethylation was extracted and pooled for diagnostic sensitivity, specificity, and summary receiver operating characteristic (SROC) curve. According to the inclusion and exclusion criteria, we finally included nine publications with 792 cases in the meta-analysis. Thus, the diagnostic sensitivity was aggregated through random effect model. The pooled sensitivity was 0.82 with the corresponding 95% confidence interval (95% CI) of 0.79-0.85; the pooled specificity and its corresponding 95% CI were 0.47 and 0.40-0.53 by the random effect model; we pooled the SROC curve by sensitivity versus specificity according to data published in the nine studies. The area under the SROC curve was 0.70 (95% CI: 0.65-0.73). SFRP2 gene promoter hypermethylation in stool can was a potential biomarker for CRC diagnosis with relative high sensitivity.

  9. Preoperative Serum Thyrotropin to Thyroglobulin Ratio Is Effective for Thyroid Nodule Evaluation in Euthyroid Patients.

    PubMed

    Wang, Lina; Li, Hao; Yang, Zhongyuan; Guo, Zhuming; Zhang, Quan

    2015-07-01

    This study was designed to assess the efficiency of the serum thyrotropin to thyroglobulin ratio for thyroid nodule evaluation in euthyroid patients. Cross-sectional study. Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China. Retrospective analysis was performed for 400 previously untreated cases presenting with thyroid nodules. Thyroid function was tested with commercially available radioimmunoassays. The receiver operating characteristic curves were constructed to determine cutoff values. The efficacy of the thyrotropin:thyroglobulin ratio and thyroid-stimulating hormone for thyroid nodule evaluation was evaluated in terms of sensitivity, specificity, positive predictive value, positive likelihood ratio, negative likelihood ratio, and odds ratio. In receiver operating characteristic curve analysis, the area under the curve was 0.746 for the thyrotropin:thyroglobulin ratio and 0.659 for thyroid-stimulating hormone. With a cutoff point value of 24.97 IU/g for the thyrotropin:thyroglobulin ratio, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 78.9%, 60.8%, 75.5%, 2.01, and 0.35, respectively. The odds ratio for the thyrotropin:thyroglobulin ratio indicating malignancy was 5.80. With a cutoff point value of 1.525 µIU/mL for thyroid-stimulating hormone, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 74.0%, 53.2%, 70.8%, 1.58, and 0.49, respectively. The odds ratio indicating malignancy for thyroid-stimulating hormone was 3.23. Increasing preoperative serum thyrotropin:thyroglobulin ratio is a risk factor for thyroid carcinoma, and the correlation of the thyrotropin:thyroglobulin ratio to malignancy is higher than that for serum thyroid-stimulating hormone. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  10. Mixture models in diagnostic meta-analyses--clustering summary receiver operating characteristic curves accounted for heterogeneity and correlation.

    PubMed

    Schlattmann, Peter; Verba, Maryna; Dewey, Marc; Walther, Mario

    2015-01-01

    Bivariate linear and generalized linear random effects are frequently used to perform a diagnostic meta-analysis. The objective of this article was to apply a finite mixture model of bivariate normal distributions that can be used for the construction of componentwise summary receiver operating characteristic (sROC) curves. Bivariate linear random effects and a bivariate finite mixture model are used. The latter model is developed as an extension of a univariate finite mixture model. Two examples, computed tomography (CT) angiography for ruling out coronary artery disease and procalcitonin as a diagnostic marker for sepsis, are used to estimate mean sensitivity and mean specificity and to construct sROC curves. The suggested approach of a bivariate finite mixture model identifies two latent classes of diagnostic accuracy for the CT angiography example. Both classes show high sensitivity but mainly two different levels of specificity. For the procalcitonin example, this approach identifies three latent classes of diagnostic accuracy. Here, sensitivities and specificities are quite different as such that sensitivity increases with decreasing specificity. Additionally, the model is used to construct componentwise sROC curves and to classify individual studies. The proposed method offers an alternative approach to model between-study heterogeneity in a diagnostic meta-analysis. Furthermore, it is possible to construct sROC curves even if a positive correlation between sensitivity and specificity is present. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Effects of structural parameters on fluid flow and mixing performance in a curved microchannel with gaps and baffles

    NASA Astrophysics Data System (ADS)

    Li, Jian; Xia, Guodong; Li, Yifan; Tian, Xinping

    2013-07-01

    We provide three-dimensional numerical simulations of mixing performance in a newly proposed micromixer with different structural parameters. The same amount of gaps and baffles are arranged along the curved channel within a certain distance. The effects of their structural parameters on mixing efficiency are presented, which include either the position and feature size of gaps and baffles, or the curvature radius of curved channel. The high efficiency mixing mechanism of the curved channel with gaps and baffles can attribute to the interaction of the increased contact area for premixed liquids, the jet and throttling effect over every unit of gap and baffle, the developing of the multidirectional vortices along the curved channel. The mixing index is sensitive to the width of the gaps and baffles for some Reynolds number ranges, but is not sensitive to the curvature radius of the curved channel. The characteristic of the pressure drop depending on Reynolds number is also investigated in order to keep an appropriate balance with mixing property.

  12. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    PubMed Central

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  13. Conformable large-area position-sensitive photodetectors based on luminescence-collecting silicone waveguides

    NASA Astrophysics Data System (ADS)

    Bartu, Petr; Koeppe, Robert; Arnold, Nikita; Neulinger, Anton; Fallon, Lisa; Bauer, Siegfried

    2010-06-01

    Position sensitive detection schemes based on the lateral photoeffect rely on inorganic semiconductors. Such position sensitive devices (PSDs) are reliable and robust, but preparation with large active areas is expensive and use on curved substrates is impossible. Here we present a novel route for the fabrication of conformable PSDs which allows easy preparation on large areas, and use on curved surfaces. Our device is based on stretchable silicone waveguides with embedded fluorescent dyes, used in conjunction with small silicon photodiodes. Impinging laser light (e.g., from a laser pointer) is absorbed by the dye in the PSD and re-emitted as fluorescence light at a larger wavelength. Due to the isotropic emission from the fluorescent dye molecules, most of the re-emitted light is coupled into the planar silicone waveguide and directed to the edges of the device. Here the light signals are detected via embedded small silicon photodiodes arranged in a regular pattern. Using a mathematical algorithm derived by extensive using of models from global positioning system (GPS) systems and human activity monitoring, the position of light spots is easily calculated. Additionally, the device shows high durability against mechanical stress, when clamped in an uniaxial stretcher and mechanically loaded up to 15% strain. The ease of fabrication, conformability, and durability of the device suggests its use as interface devices and as sensor skin for future robots.

  14. Nonlinear mathematical modeling and sensitivity analysis of hydraulic drive unit

    NASA Astrophysics Data System (ADS)

    Kong, Xiangdong; Yu, Bin; Quan, Lingxiao; Ba, Kaixian; Wu, Liujie

    2015-09-01

    The previous sensitivity analysis researches are not accurate enough and also have the limited reference value, because those mathematical models are relatively simple and the change of the load and the initial displacement changes of the piston are ignored, even experiment verification is not conducted. Therefore, in view of deficiencies above, a nonlinear mathematical model is established in this paper, including dynamic characteristics of servo valve, nonlinear characteristics of pressure-flow, initial displacement of servo cylinder piston and friction nonlinearity. The transfer function block diagram is built for the hydraulic drive unit closed loop position control, as well as the state equations. Through deriving the time-varying coefficient items matrix and time-varying free items matrix of sensitivity equations respectively, the expression of sensitivity equations based on the nonlinear mathematical model are obtained. According to structure parameters of hydraulic drive unit, working parameters, fluid transmission characteristics and measured friction-velocity curves, the simulation analysis of hydraulic drive unit is completed on the MATLAB/Simulink simulation platform with the displacement step 2 mm, 5 mm and 10 mm, respectively. The simulation results indicate that the developed nonlinear mathematical model is sufficient by comparing the characteristic curves of experimental step response and simulation step response under different constant load. Then, the sensitivity function time-history curves of seventeen parameters are obtained, basing on each state vector time-history curve of step response characteristic. The maximum value of displacement variation percentage and the sum of displacement variation absolute values in the sampling time are both taken as sensitivity indexes. The sensitivity indexes values above are calculated and shown visually in histograms under different working conditions, and change rules are analyzed. Then the sensitivity indexes values of four measurable parameters, such as supply pressure, proportional gain, initial position of servo cylinder piston and load force, are verified experimentally on test platform of hydraulic drive unit, and the experimental research shows that the sensitivity analysis results obtained through simulation are approximate to the test results. This research indicates each parameter sensitivity characteristics of hydraulic drive unit, the performance-affected main parameters and secondary parameters are got under different working conditions, which will provide the theoretical foundation for the control compensation and structure optimization of hydraulic drive unit.

  15. Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia

    PubMed Central

    Dinh, C H; Ng, R; Grandinetti, A; Joffe, A; Chow, D C

    2006-01-01

    Background An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gap's poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate ⩾2.5 mmol/l. Methods A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients' laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated. Results An anion gap ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively. Conclusions The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia. PMID:16858097

  16. Nondestructive method and apparatus for imaging grains in curved surfaces of polycrystalline articles

    DOEpatents

    Carpenter, Donald A.

    1995-01-01

    A nondestructive method, and associated apparatus, are provided for determining the grain flow of the grains in a convex curved, textured polycrystalline surface. The convex, curved surface of a polycrystalline article is aligned in a horizontal x-ray diffractometer and a monochromatic, converging x-ray beam is directed onto the curved surface of the polycrystalline article so that the converging x-ray beam is diffracted by crystallographic planes of the grains in the polycrystalline article. The diffracted x-ray beam is caused to pass through a set of horizontal, parallel slits to limit the height of the beam and thereafter. The linear intensity of the diffracted x-ray is measured, using a linear position sensitive proportional counter, as a function of position in a direction orthogonal to the counter so as to generate two dimensional data. An image of the grains in the curved surface of the polycrystalline article is provided based on the two-dimensional data.

  17. Nondestructive method and apparatus for imaging grains in curved surfaces of polycrystalline articles

    DOEpatents

    Carpenter, D.A.

    1995-05-23

    A nondestructive method, and associated apparatus, are provided for determining the grain flow of the grains in a convex curved, textured polycrystalline surface. The convex, curved surface of a polycrystalline article is aligned in a horizontal x-ray diffractometer and a monochromatic, converging x-ray beam is directed onto the curved surface of the polycrystalline article so that the converging x-ray beam is diffracted by crystallographic planes of the grains in the polycrystalline article. The diffracted x-ray beam is caused to pass through a set of horizontal, parallel slits to limit the height of the beam and thereafter. The linear intensity of the diffracted x-ray is measured, using a linear position sensitive proportional counter, as a function of position in a direction orthogonal to the counter so as to generate two dimensional data. An image of the grains in the curved surface of the polycrystalline article is provided based on the two-dimensional data. 7 Figs.

  18. Sensitivity and specificity of the Distress Thermometer in screening for distress in long-term nasopharyngeal cancer survivors.

    PubMed

    Hong, J S; Tian, J

    2013-12-01

    The Distress Thermometer (dt) is a screening tool recommended to quickly identify cancer patients with distress. Our study aimed to examine the sensitivity and specificity of the dt in detecting psychological distress in long-term Chinese nasopharyngeal cancer (npc) survivors. Data for the 442 participating npc survivors were collected through a self-administered questionnaire based on the dt and the Hospital Anxiety and Depression Scale (hads). The hads was used to define cases of psychological distress. Positive and negative groups were defined based on 4 hads criteria (Anxiety, Depression, Anxiety or Depression, and overall score). Receiver operating characteristic (roc) curves were used to examine the ability of all possible cut-off values of the dt to detect positive and negative cases. For each roc curve, the area under the curve (auc) was used as an indicator of the overall accuracy of the dt to identify positive cases of distress. The positive auc values [with 95% confidence intervals (ci)] for the 4 hads criteria were 0.715 (95% ci: 0.667 to 0.764), 0.714 (95% ci: 0.661 to 0.768), 0.724 (95% ci: 0.677 to 0.771), and 0.724 (95% ci: 0.664 to 0.775) respectively. At a cut-off score of 4, the sensitivity of the dt to the four hads criteria was, respectively, 0.366 (95% ci: 0.296 to 0.436), 0.448 (95% ci: 0.364 to 0.532), 0.362 (95% ci: 0.299 to 0.425), and 0.421 (95% ci: 0.339 to 0.502), and the specificity of the dt to the 4 hads criteria was, respectively, 0.860 (95% ci: 0.818 to 0.902), 0.860 (95% ci: 0.821 to 0.899), 0.854 (95% ci: 0.814 to 0.894), and 0.854 (95% ci: 0.814 to 0.894). At a cut-off score of 5, the corresponding sensitivities were lower than those at the cut-off score of 4. All potential cut-off scores showed poor sensitivity (<0.90). The roc analysis showed poor discrimination. No potential dt cut-off score had an acceptable sensitivity. The dt showed poor sensitivity in npc survivors. Thus, the dt might not be a valid scale for psychological distress screening in long-term Chinese npc survivors.

  19. Sensitivity and specificity of the Distress Thermometer in screening for distress in long-term nasopharyngeal cancer survivors

    PubMed Central

    Hong, J.S.; Tian, J.

    2013-01-01

    Background The Distress Thermometer (dt) is a screening tool recommended to quickly identify cancer patients with distress. Our study aimed to examine the sensitivity and specificity of the dt in detecting psychological distress in long-term Chinese nasopharyngeal cancer (npc) survivors. Methods Data for the 442 participating npc survivors were collected through a self-administered questionnaire based on the dt and the Hospital Anxiety and Depression Scale (hads). The hads was used to define cases of psychological distress. Positive and negative groups were defined based on 4 hads criteria (Anxiety, Depression, Anxiety or Depression, and overall score). Receiver operating characteristic (roc) curves were used to examine the ability of all possible cut-off values of the dt to detect positive and negative cases. For each roc curve, the area under the curve (auc) was used as an indicator of the overall accuracy of the dt to identify positive cases of distress. Results The positive auc values [with 95% confidence intervals (ci)] for the 4 hads criteria were 0.715 (95% ci: 0.667 to 0.764), 0.714 (95% ci: 0.661 to 0.768), 0.724 (95% ci: 0.677 to 0.771), and 0.724 (95% ci: 0.664 to 0.775) respectively. At a cut-off score of 4, the sensitivity of the dt to the four hads criteria was, respectively, 0.366 (95% ci: 0.296 to 0.436), 0.448 (95% ci: 0.364 to 0.532), 0.362 (95% ci: 0.299 to 0.425), and 0.421 (95% ci: 0.339 to 0.502), and the specificity of the dt to the 4 hads criteria was, respectively, 0.860 (95% ci: 0.818 to 0.902), 0.860 (95% ci: 0.821 to 0.899), 0.854 (95% ci: 0.814 to 0.894), and 0.854 (95% ci: 0.814 to 0.894). At a cut-off score of 5, the corresponding sensitivities were lower than those at the cut-off score of 4. All potential cut-off scores showed poor sensitivity (<0.90). Conclusions The roc analysis showed poor discrimination. No potential dt cut-off score had an acceptable sensitivity. The dt showed poor sensitivity in npc survivors. Thus, the dt might not be a valid scale for psychological distress screening in long-term Chinese npc survivors. PMID:24311958

  20. An extension of the receiver operating characteristic curve and AUC-optimal classification.

    PubMed

    Takenouchi, Takashi; Komori, Osamu; Eguchi, Shinto

    2012-10-01

    While most proposed methods for solving classification problems focus on minimization of the classification error rate, we are interested in the receiver operating characteristic (ROC) curve, which provides more information about classification performance than the error rate does. The area under the ROC curve (AUC) is a natural measure for overall assessment of a classifier based on the ROC curve. We discuss a class of concave functions for AUC maximization in which a boosting-type algorithm including RankBoost is considered, and the Bayesian risk consistency and the lower bound of the optimum function are discussed. A procedure derived by maximizing a specific optimum function has high robustness, based on gross error sensitivity. Additionally, we focus on the partial AUC, which is the partial area under the ROC curve. For example, in medical screening, a high true-positive rate to the fixed lower false-positive rate is preferable and thus the partial AUC corresponding to lower false-positive rates is much more important than the remaining AUC. We extend the class of concave optimum functions for partial AUC optimality with the boosting algorithm. We investigated the validity of the proposed method through several experiments with data sets in the UCI repository.

  1. The test characteristics of head circumference measurements for pathology associated with head enlargement: a retrospective cohort study

    PubMed Central

    2012-01-01

    Background The test characteristics of head circumference (HC) measurement percentile criteria for the identification of previously undetected pathology associated with head enlargement in primary care are unknown. Methods Electronic patient records were reviewed to identify children age 3 days to 3 years with new diagnoses of intracranial expansive conditions (IEC) and metabolic and genetic conditions associated with macrocephaly (MGCM). We tested the following HC percentile threshold criteria: ever above the 95th, 97th, or 99.6th percentile and ever crossing 2, 4, or 6 increasing major percentile lines. The Centers for Disease Control and World Health Organization growth curves were used, as well as the primary care network (PCN) curves previously derived from this cohort. Results Among 74,428 subjects, 85 (0.11%) had a new diagnosis of IEC (n = 56) or MGCM (n = 29), and between these 2 groups, 24 received intervention. The 99.6th percentile of the PCN curve was the only threshold with a PPV over 1% (PPV 1.8%); the sensitivity of this threshold was only 15%. Test characteristics for the 95th percentiles were: sensitivity (CDC: 46%; WHO: 55%; PCN: 40%), positive predictive value (PPV: CDC: 0.3%; WHO: 0.3%; PCN: 0.4%), and likelihood ratios positive (LR+: CDC: 2.8; WHO: 2.2; PCN: 3.9). Test characteristics for the 97th percentiles were: sensitivity (CDC: 40%; WHO: 48%; PCN: 34%), PPV (CDC: 0.4%; WHO: 0.3%; PCN: 0.6%), and LR+ (CDC: 3.6; WHO: 2.7; PCN: 5.6). Test characteristics for crossing 2 increasing major percentile lines were: sensitivity (CDC: 60%; WHO: 40%; PCN: 31%), PPV (CDC: 0.2%; WHO: 0.1%; PCN: 0.2%), and LR+ (CDC: 1.3; WHO: 1.1; PCN: 1.5). Conclusions Commonly used HC percentile thresholds had low sensitivity and low positive predictive value for diagnosing new pathology associated with head enlargement in children in a primary care network. PMID:22269214

  2. Meta-analysis of Diagnostic Accuracy and ROC Curves with Covariate Adjusted Semiparametric Mixtures.

    PubMed

    Doebler, Philipp; Holling, Heinz

    2015-12-01

    Many screening tests dichotomize a measurement to classify subjects. Typically a cut-off value is chosen in a way that allows identification of an acceptable number of cases relative to a reference procedure, but does not produce too many false positives at the same time. Thus for the same sample many pairs of sensitivities and false positive rates result as the cut-off is varied. The curve of these points is called the receiver operating characteristic (ROC) curve. One goal of diagnostic meta-analysis is to integrate ROC curves and arrive at a summary ROC (SROC) curve. Holling, Böhning, and Böhning (Psychometrika 77:106-126, 2012a) demonstrated that finite semiparametric mixtures can describe the heterogeneity in a sample of Lehmann ROC curves well; this approach leads to clusters of SROC curves of a particular shape. We extend this work with the help of the [Formula: see text] transformation, a flexible family of transformations for proportions. A collection of SROC curves is constructed that approximately contains the Lehmann family but in addition allows the modeling of shapes beyond the Lehmann ROC curves. We introduce two rationales for determining the shape from the data. Using the fact that each curve corresponds to a natural univariate measure of diagnostic accuracy, we show how covariate adjusted mixtures lead to a meta-regression on SROC curves. Three worked examples illustrate the method.

  3. Value of contrast-enhanced ultrasound in differential diagnosis of solid lesions of pancreas (SLP): A systematic review and a meta-analysis.

    PubMed

    Ran, Li; Zhao, Wenli; Zhao, Ye; Bu, Huaien

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) is considered a novel method for diagnosing pancreatic cancer, but currently, there is no conclusive evidence of its accuracy. Using CEUS in discriminating between pancreatic carcinoma and other pancreatic lesions, we aimed to evaluate the diagnostic accuracy of CEUS in predicting pancreatic tumours. Relevant studies were selected from the PubMed, Cochrane Library, Elsevier, CNKI, VIP, and WANFANG databases dating from January 2006 to May 2017. The following terms were used as keywords: "pancreatic cancer" OR "pancreatic carcinoma," "contrast-enhanced ultrasonography" OR "contrast-enhanced ultrasound" OR "CEUS," and "diagnosis." The selection criteria are as follows: pancreatic carcinomas diagnosed by CEUS while the main reference standard was surgical pathology or biopsy (if it involved a clinical diagnosis, particular criteria emphasized); SonoVue or Levovist was the contrast agent; true positive, false positive, false negative, and true negative rates were obtained or calculated to construct the 2 × 2 contingency table; English or Chinese articles; at least 20 patients were enrolled in each group. The Quality Assessment for Studies of Diagnostic Accuracy was employed to evaluate the quality of articles. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver-operating characteristic curves, and the area under curve were evaluated to estimate the overall diagnostic efficiency. Pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated with fixed-effect models. Eight of 184 records were eligible for a meta-analysis after independent scrutinization by 2 reviewers. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were 0.86 (95% CI 0.81-0.90), 0.75 (95% CI 0.68-0.82), 3.56 (95% CI 2.64-4.78), 0.19 (95% CI 0.13-0.27), and 22.260 (95% CI 8.980-55.177), respectively. The area under the SROC curve was 0.9088. CEUS has a satisfying pooled sensitivity and specificity for discriminating pancreatic cancer from other pancreatic lesions.

  4. Sensitivity and Specificity of Interictal EEG-fMRI for Detecting the Ictal Onset Zone at Different Statistical Thresholds

    PubMed Central

    Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim

    2014-01-01

    There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049

  5. Local indicators of geocoding accuracy (LIGA): theory and application

    PubMed Central

    Jacquez, Geoffrey M; Rommel, Robert

    2009-01-01

    Background Although sources of positional error in geographic locations (e.g. geocoding error) used for describing and modeling spatial patterns are widely acknowledged, research on how such error impacts the statistical results has been limited. In this paper we explore techniques for quantifying the perturbability of spatial weights to different specifications of positional error. Results We find that a family of curves describes the relationship between perturbability and positional error, and use these curves to evaluate sensitivity of alternative spatial weight specifications to positional error both globally (when all locations are considered simultaneously) and locally (to identify those locations that would benefit most from increased geocoding accuracy). We evaluate the approach in simulation studies, and demonstrate it using a case-control study of bladder cancer in south-eastern Michigan. Conclusion Three results are significant. First, the shape of the probability distributions of positional error (e.g. circular, elliptical, cross) has little impact on the perturbability of spatial weights, which instead depends on the mean positional error. Second, our methodology allows researchers to evaluate the sensitivity of spatial statistics to positional accuracy for specific geographies. This has substantial practical implications since it makes possible routine sensitivity analysis of spatial statistics to positional error arising in geocoded street addresses, global positioning systems, LIDAR and other geographic data. Third, those locations with high perturbability (most sensitive to positional error) and high leverage (that contribute the most to the spatial weight being considered) will benefit the most from increased positional accuracy. These are rapidly identified using a new visualization tool we call the LIGA scatterplot. Herein lies a paradox for spatial analysis: For a given level of positional error increasing sample density to more accurately follow the underlying population distribution increases perturbability and introduces error into the spatial weights matrix. In some studies positional error may not impact the statistical results, and in others it might invalidate the results. We therefore must understand the relationships between positional accuracy and the perturbability of the spatial weights in order to have confidence in a study's results. PMID:19863795

  6. Application of Mycobacterium Leprae-specific cellular and serological tests for the differential diagnosis of leprosy from confounding dermatoses.

    PubMed

    Freitas, Aline Araújo; Hungria, Emerith Mayra; Costa, Maurício Barcelos; Sousa, Ana Lúcia Osório Maroccolo; Castilho, Mirian Lane Oliveira; Gonçalves, Heitor Sá; Pontes, Maria Araci Andrade; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2016-10-01

    Mycobacterium leprae-specific serological and cell-mediated-immunity/CMI test were evaluated for the differential diagnosis of multibacillary/MB, and paucibacillary/PB leprosy from other dermatoses. Whole-blood assay/WBA/IFNγ stimulated with LID-1 antigen and ELISA tests for IgG to LID-1 and IgM to PGL-I were performed. WBA/LID-1/IFNγ production was observed in 72% PB, 11% MB leprosy, 38% dermatoses, 40% healthy endemic controls/EC. The receiver operating curve/ROC for WBA/LID-1 in PB versus other dermatoses showed 72.5% sensitivity, 61.5% specificity and an area-under-the-curve/AUC=0.75; 74% positive predictive value/PPV, 59% negative predictive value/NPV. Anti PGL-I serology was positive in 67% MB, 8% PB leprosy, 6% of other dermatoses; its sensitivity for MB=66%, specificity=93%, AUC=0.89; PPV=91%, NPV=72%. Anti-LID-1 serology was positive in 87% MB, 7% PB leprosy, all other participants were seronegative; 87.5% sensitivity for MB, 100% specificity, AUC=0.97; PPV=100%, NPV=88%. In highly endemic areas anti-LID-1/PGL-I serology and WBA/LID-1-represent useful tools for the differential diagnosis of leprosy from other confounding dermatoses. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Determination of IgE antibodies to the benzylpenicilloyl determinant: a comparison of the sensitivity and specificity of three radio allergo sorbent test methods.

    PubMed

    Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E

    1997-01-01

    The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.

  8. Sensitivity and specificity of the lymphocyte transformation test in drug reaction with eosinophilia and systemic symptoms causality assessment.

    PubMed

    Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T

    2018-03-01

    Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.

  9. Association of C-Reactive Protein With Bacterial and Respiratory Syncytial Virus–Associated Pneumonia Among Children Aged <5 Years in the PERCH Study

    PubMed Central

    Le, Tham; O’Brien, Katherine L.; Murdoch, David R.; Prosperi, Christine; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Kotloff, Karen L.; Levine, Orin S.; Scott, J. Anthony G.; Thea, Donald M.; Awori, Juliet O.; Baillie, Vicky L.; Cascio, Stephanie; Chuananon, Somchai; DeLuca, Andrea N.; Driscoll, Amanda J.; Ebruke, Bernard E.; Endtz, Hubert P.; Kaewpan, Anek; Kahn, Geoff; Karani, Angela; Karron, Ruth A.; Moore, David P.; Park, Daniel E.; Rahman, Mohammed Ziaur; Salaudeen, Rasheed; Seidenberg, Phil; Somwe, Somwe Wa; Sylla, Mamadou; Tapia, Milagritos D.; Zeger, Scott L.; Deloria Knoll, Maria; Madhi, Shabir A.; O’Brien, Katherine L.; Levine, Orin S.; Knoll, Maria Deloria; Feikin, Daniel R.; DeLuca, Andrea N.; Driscoll, Amanda J.; Fancourt, Nicholas; Fu, Wei; Hammitt, Laura L.; Higdon, Melissa M.; Kagucia, E. Wangeci; Karron, Ruth A.; Li, Mengying; Park, Daniel E.; Prosperi, Christine; Wu, Zhenke; Zeger, Scott L.; Watson, Nora L.; Crawley, Jane; Murdoch, David R.; Brooks, W. Abdullah; Endtz, Hubert P.; Zaman, Khalequ; Goswami, Doli; Hossain, Lokman; Jahan, Yasmin; Ashraf, Hasan; Howie, Stephen R. C.; Ebruke, Bernard E.; Antonio, Martin; McLellan, Jessica; Machuka, Eunice; Shamsul, Arifin; Zaman, Syed M.A.; Mackenzie, Grant; Scott, J. Anthony G.; Awori, Juliet O.; Morpeth, Susan C.; Kamau, Alice; Kazungu, Sidi; Ominde, Micah Silaba; Kotloff, Karen L.; Tapia, Milagritos D.; Sow, Samba O.; Sylla, Mamadou; Tamboura, Boubou; Onwuchekwa, Uma; Kourouma, Nana; Toure, Aliou; Madhi, Shabir A.; Moore, David P.; Adrian, Peter V.; Baillie, Vicky L.; Kuwanda, Locadiah; Mudau, Azwifarwi; Groome, Michelle J.; Mahomed, Nasreen; Baggett, Henry C.; Thamthitiwat, Somsak; Maloney, Susan A.; Bunthi, Charatdao; Rhodes, Julia; Sawatwong, Pongpun; Akarasewi, Pasakorn; Thea, Donald M.; Mwananyanda, Lawrence; Chipeta, James; Seidenberg, Phil; Mwansa, James; Wa Somwe, Somwe; Kwenda, Geoffrey; Anderson, Trevor P.; Mitchell, Joanne

    2017-01-01

    Abstract Background. Lack of a gold standard for identifying bacterial and viral etiologies of pneumonia has limited evaluation of C-reactive protein (CRP) for identifying bacterial pneumonia. We evaluated the sensitivity and specificity of CRP for identifying bacterial vs respiratory syncytial virus (RSV) pneumonia in the Pneumonia Etiology Research for Child Health (PERCH) multicenter case-control study. Methods. We measured serum CRP levels in cases with World Health Organization–defined severe or very severe pneumonia and a subset of community controls. We evaluated the sensitivity and specificity of elevated CRP for “confirmed” bacterial pneumonia (positive blood culture or positive lung aspirate or pleural fluid culture or polymerase chain reaction [PCR]) compared to “RSV pneumonia” (nasopharyngeal/oropharyngeal or induced sputum PCR-positive without confirmed/suspected bacterial pneumonia). Receiver operating characteristic (ROC) curves were constructed to assess the performance of elevated CRP in distinguishing these cases. Results. Among 601 human immunodeficiency virus (HIV)–negative tested controls, 3% had CRP ≥40 mg/L. Among 119 HIV-negative cases with confirmed bacterial pneumonia, 77% had CRP ≥40 mg/L compared with 17% of 556 RSV pneumonia cases. The ROC analysis produced an area under the curve of 0.87, indicating very good discrimination; a cut-point of 37.1 mg/L best discriminated confirmed bacterial pneumonia (sensitivity 77%) from RSV pneumonia (specificity 82%). CRP ≥100 mg/L substantially improved specificity over CRP ≥40 mg/L, though at a loss to sensitivity. Conclusions. Elevated CRP was positively associated with confirmed bacterial pneumonia and negatively associated with RSV pneumonia in PERCH. CRP may be useful for distinguishing bacterial from RSV-associated pneumonia, although its role in discriminating against other respiratory viral-associated pneumonia needs further study. PMID:28575375

  10. The Stroke Assessment of Fall Risk (SAFR): predictive validity in inpatient stroke rehabilitation.

    PubMed

    Breisinger, Terry P; Skidmore, Elizabeth R; Niyonkuru, Christian; Terhorst, Lauren; Campbell, Grace B

    2014-12-01

    To evaluate relative accuracy of a newly developed Stroke Assessment of Fall Risk (SAFR) for classifying fallers and non-fallers, compared with a health system fall risk screening tool, the Fall Harm Risk Screen. Prospective quality improvement study conducted at an inpatient stroke rehabilitation unit at a large urban university hospital. Patients admitted for inpatient stroke rehabilitation (N = 419) with imaging or clinical evidence of ischemic or hemorrhagic stroke, between 1 August 2009 and 31 July 2010. Not applicable. Sensitivity, specificity, and area under the curve for Receiver Operating Characteristic Curves of both scales' classifications, based on fall risk score completed upon admission to inpatient stroke rehabilitation. A total of 68 (16%) participants fell at least once. The SAFR was significantly more accurate than the Fall Harm Risk Screen (p < 0.001), with area under the curve of 0.73, positive predictive value of 0.29, and negative predictive value of 0.94. For the Fall Harm Risk Screen, area under the curve was 0.56, positive predictive value was 0.19, and negative predictive value was 0.86. Sensitivity and specificity of the SAFR (0.78 and 0.63, respectively) was higher than the Fall Harm Risk Screen (0.57 and 0.48, respectively). An evidence-derived, population-specific fall risk assessment may more accurately predict fallers than a general fall risk screen for stroke rehabilitation patients. While the SAFR improves upon the accuracy of a general assessment tool, additional refinement may be warranted. © The Author(s) 2014.

  11. Development of a Pediatric Ebola Predictive Score, Sierra Leone1.

    PubMed

    Fitzgerald, Felicity; Wing, Kevin; Naveed, Asad; Gbessay, Musa; Ross, J C G; Checchi, Francesco; Youkee, Daniel; Jalloh, Mohamed Boie; Baion, David E; Mustapha, Ayeshatu; Jah, Hawanatu; Lako, Sandra; Oza, Shefali; Boufkhed, Sabah; Feury, Reynold; Bielicki, Julia; Williamson, Elizabeth; Gibb, Diana M; Klein, Nigel; Sahr, Foday; Yeung, Shunmay

    2018-02-01

    We compared children who were positive for Ebola virus disease (EVD) with those who were negative to derive a pediatric EVD predictor (PEP) score. We collected data on all children <13 years of age admitted to 11 Ebola holding units in Sierra Leone during August 2014-March 2015 and performed multivariable logistic regression. Among 1,054 children, 309 (29%) were EVD positive and 697 (66%) EVD negative, with 48 (5%) missing. Contact history, conjunctivitis, and age were the strongest positive predictors for EVD. The PEP score had an area under receiver operating characteristics curve of 0.80. A PEP score of 7/10 was 92% specific and 44% sensitive; 3/10 was 30% specific, 94% sensitive. The PEP score could correctly classify 79%-90% of children and could be used to facilitate triage into risk categories, depending on the sensitivity or specificity required.

  12. A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2011-01-01

    Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

  13. Dynamic thresholds and a summary ROC curve: Assessing prognostic accuracy of longitudinal markers.

    PubMed

    Saha-Chaudhuri, P; Heagerty, P J

    2018-04-19

    Cancer patients, chronic kidney disease patients, and subjects infected with HIV are routinely monitored over time using biomarkers that represent key health status indicators. Furthermore, biomarkers are frequently used to guide initiation of new treatments or to inform changes in intervention strategies. Since key medical decisions can be made on the basis of a longitudinal biomarker, it is important to evaluate the potential accuracy associated with longitudinal monitoring. To characterize the overall accuracy of a time-dependent marker, we introduce a summary ROC curve that displays the overall sensitivity associated with a time-dependent threshold that controls time-varying specificity. The proposed statistical methods are similar to concepts considered in disease screening, yet our methods are novel in choosing a potentially time-dependent threshold to define a positive test, and our methods allow time-specific control of the false-positive rate. The proposed summary ROC curve is a natural averaging of time-dependent incident/dynamic ROC curves and therefore provides a single summary of net error rates that can be achieved in the longitudinal setting. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Universal aspects of brittle fracture, adhesion, and atomic force microscopy

    NASA Technical Reports Server (NTRS)

    Banerjea, Amitava; Ferrante, John; Smith, John R.

    1989-01-01

    This universal relation between binding energy and interatomic separation was originally discovered for adhesion at bimetallic interfaces involving the simple metals Al, Zn, Mg, and Na. It is shown here that the same universal relation extends to adhesion at transition-metal interfaces. Adhesive energies have been computed for the low-index interfaces of Al, Ni, Cu, Ag, Fe, and W, using the equivalent-crystal theory (ECT) and keeping the atoms in each semiinfinite slab fixed rigidly in their equilibrium positions. These adhesive energy curves can be scaled onto each other and onto the universal adhesion curve. The effect of tip shape on the adhesive forces in the atomic-force microscope (AFM) is studied by computing energies and forces using the ECT. While the details of the energy-distance and force-distance curves are sensitive to tip shape, all of these curves can be scaled onto the universal adhesion curve.

  15. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    PubMed

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  16. The multiple hop test: a discriminative or evaluative instrument for chronic ankle instability?

    PubMed

    Eechaute, Christophe; Bautmans, Ivan; De Hertogh, Willem; Vaes, Peter

    2012-05-01

    To determine whether the multiple hop test should be used as an evaluative or a discriminative instrument for chronic ankle instability (CAI). Blinded case-control study. : University research laboratory. Twenty-nine healthy subjects (21 men, 8 women, mean age 21.8 years) and 29 patients with CAI (17 men, 12 women, mean age 24.9 years) were selected. Subjects performed a multiple hop test and hopped on 10 different tape markers while trying to avoid any postural correction. Minimal detectable changes (MDC) of the number of balance errors, the time value, and the visual analog scale (VAS) score (perceived difficulty) were calculated as evaluative measures. For the discriminative properties, a receiver operating characteristic curve was determined and the area under curve (AUC), the sensitivity, specificity, diagnostic accuracy (DA), and likelihood ratios (LR) were calculated whether 1, 2, or 3 outcomes were positive. Based on their MDC, outcomes should, respectively, change by more than 7 errors (41%), 6 seconds (15%), and 27 mm (55%, VAS score) before considering it as a real change. Area under curves were, respectively, 79% (errors), 77% (time value), and 65% (VAS score). The most optimal cutoff point was, respectively, 13.5 errors, 35 seconds, and 32.5 mm. When 2 of 3 outcomes were positive, the sensitivity was 86%, the specificity was 79%, the DA was 83%, the positive LR was 4.2, and the negative LR was 0.17. The multiple hop test seems to be more a discriminative instrument for CAI, and its responsiveness needs to be demonstrated.

  17. Software for illustrative presentation of basic clinical characteristics of laboratory tests--GraphROC for Windows.

    PubMed

    Kairisto, V; Poola, A

    1995-01-01

    GraphROC for Windows is a program for clinical test evaluation. It was designed for the handling of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be "picked up" from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and health-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.

  18. Development of a position sensitive X-ray detector for use in a light weight X-ray diffractometer

    NASA Technical Reports Server (NTRS)

    Semmler, R. A.

    1971-01-01

    A position sensitive proportional counter for use in an X-ray diffractometer is developed to permit drastic reductions in the power and weight requirements of the X-ray source and the elimination of the power, weight, and complexity of a moving slit. The final detector constructed and tested has a window spanning 138 and a free standing anode curved along an arc of 7.1 cm radius. Demonstration spectra of a quartz sample in a Debye-Sherrer geometry indicate a spatial resolution of 0.4 - 0.5 mm (0.3 - 0.4 theta). The lunar diffractometer consumed 25 watts in the X-ray generator and weighed about 20 pounds.

  19. [Evaluation of performance of five bioinformatics software for the prediction of missense mutations].

    PubMed

    Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen

    2016-10-01

    To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.

  20. SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehnke, E McKenzie; DeMarco, J; Steers, J

    2016-06-15

    Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readingsmore » are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.« less

  1. Type 2 diabetes and cardiac autonomic neuropathy screening using dynamic pupillometry

    PubMed Central

    Lerner, Alana G.; Bernabé-Ortiz, Antonio; Ticse, Ray; Hernandez, Arturo; Huaylinos, Yvonne; Pinto, Miguel E.; Málaga, Germán; Checkley, William; Gilman, Robert H.; Miranda, J. Jaime

    2015-01-01

    Aim To determine if changes in pupillary response are useful as a screening tool for diabetes and to assess whether pupillometry is associated with cardiac autonomic neuropathy. Methods We conducted a cross-sectional study with participants drawn from two settings: a hospital and a community site. At the community site, individuals with newly diagnosed diabetes as well as a random sample of control individuals without diabetes, confirmed by oral glucose tolerance test, were selected. Participants underwent an LED light stimulus test and eight pupillometry variables were measured. Outcomes were diabetes, defined by oral glucose tolerance test, and cardiac autonomic dysfunction, determined by a positive readout on two of four diagnostic tests: heart rate response to the Valsalva manoeuvre; orthostatic hypotension; 30:15 ratio; and expiration-to-inspiration ratio. The area under the curve, best threshold, sensitivity and specificity of each pupillometry variable was calculated. Results Data from 384 people, 213 with diabetes, were analysed. The mean (±SD) age of the people with diabetes was 58.6 (±8.2) years and in the control subjects it was 56.1 (±8.6) years. When comparing individuals with and without diabetes, the amplitude of the pupil reaction had the highest area under the curve [0.69 (sensitivity: 78%; specificity: 55%)]. Cardiac autonomic neuropathy was present in 51 of the 138 people evaluated (37.0%; 95% CI 28.8–45.1). To diagnose cardiac autonomic neuropathy, two pupillometry variables had the highest area under the curve: baseline pupil radius [area under the curve: 0.71 (sensitivity: 51%; specificity: 84%)], and amplitude of the pupil reaction [area under the curve: 070 (sensitivity: 82%; specificity: 55%)]. Conclusions Pupillometry is an inexpensive technique to screen for diabetes and cardiac autonomic neuropathy, but it does not have sufficient accuracy for clinical use as a screening tool. PMID:25761508

  2. Type 2 diabetes and cardiac autonomic neuropathy screening using dynamic pupillometry.

    PubMed

    Lerner, A G; Bernabé-Ortiz, A; Ticse, R; Hernandez, A; Huaylinos, Y; Pinto, M E; Málaga, G; Checkley, W; Gilman, R H; Miranda, J J

    2015-11-01

    To determine if changes in pupillary response are useful as a screening tool for diabetes and to assess whether pupillometry is associated with cardiac autonomic neuropathy. We conducted a cross-sectional study with participants drawn from two settings: a hospital and a community site. At the community site, individuals with newly diagnosed diabetes as well as a random sample of control individuals without diabetes, confirmed by oral glucose tolerance test, were selected. Participants underwent an LED light stimulus test and eight pupillometry variables were measured. Outcomes were diabetes, defined by oral glucose tolerance test, and cardiac autonomic dysfunction, determined by a positive readout on two of four diagnostic tests: heart rate response to the Valsalva manoeuvre; orthostatic hypotension; 30:15 ratio; and expiration-to-inspiration ratio. The area under the curve, best threshold, sensitivity and specificity of each pupillometry variable was calculated. Data from 384 people, 213 with diabetes, were analysed. The mean (±sd) age of the people with diabetes was 58.6 (±8.2) years and in the control subjects it was 56.1 (±8.6) years. When comparing individuals with and without diabetes, the amplitude of the pupil reaction had the highest area under the curve [0.69 (sensitivity: 78%; specificity: 55%)]. Cardiac autonomic neuropathy was present in 51 of the 138 people evaluated (37.0%; 95% CI 28.8-45.1). To diagnose cardiac autonomic neuropathy, two pupillometry variables had the highest area under the curve: baseline pupil radius [area under the curve: 0.71 (sensitivity: 51%; specificity: 84%)], and amplitude of the pupil reaction [area under the curve: 0.70 (sensitivity: 82%; specificity: 55%)]. Pupillometry is an inexpensive technique to screen for diabetes and cardiac autonomic neuropathy, but it does not have sufficient accuracy for clinical use as a screening tool. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  3. 14-3-3η Autoantibodies: Diagnostic Use in Early Rheumatoid Arthritis.

    PubMed

    Maksymowych, Walter P; Boire, Gilles; van Schaardenburg, Dirkjan; Wichuk, Stephanie; Turk, Samina; Boers, Maarten; Siminovitch, Katherine A; Bykerk, Vivian; Keystone, Ed; Tak, Paul Peter; van Kuijk, Arno W; Landewé, Robert; van der Heijde, Desiree; Murphy, Mairead; Marotta, Anthony

    2015-09-01

    To describe the expression and diagnostic use of 14-3-3η autoantibodies in early rheumatoid arthritis (RA). 14-3-3η autoantibody levels were measured using an electrochemiluminescent multiplexed assay in 500 subjects (114 disease-modifying antirheumatic drug-naive patients with early RA, 135 with established RA, 55 healthy, 70 autoimmune, and 126 other non-RA arthropathy controls). 14-3-3η protein levels were determined in an earlier analysis. Two-tailed Student t tests and Mann-Whitney U tests compared differences among groups. Receiver-operator characteristic (ROC) curves were generated and diagnostic performance was estimated by area under the curve (AUC), as well as specificity, sensitivity, and likelihood ratios (LR) for optimal cutoffs. Median serum 14-3-3η autoantibody concentrations were significantly higher (p < 0.0001) in patients with early RA (525 U/ml) when compared with healthy controls (235 U/ml), disease controls (274 U/ml), autoimmune disease controls (274 U/ml), patients with osteoarthritis (259 U/ml), and all controls (265 U/ml). ROC curve analysis comparing early RA with healthy controls demonstrated a significant (p < 0.0001) AUC of 0.90 (95% CI 0.85-0.95). At an optimal cutoff of ≥ 380 U/ml, the ROC curve yielded a sensitivity of 73%, a specificity of 91%, and a positive LR of 8.0. Adding 14-3-3η autoantibodies to 14-3-3η protein positivity enhanced the identification of patients with early RA from 59% to 90%; addition of 14-3-3η autoantibodies to anticitrullinated protein antibodies (ACPA) and/or rheumatoid factor (RF) increased identification from 72% to 92%. Seventy-two percent of RF- and ACPA-seronegative patients were positive for 14-3-3η autoantibodies. 14-3-3η autoantibodies, alone and in combination with the 14-3-3η protein, RF, and/or ACPA identified most patients with early RA.

  4. Predicting Likelihood of Having Four or More Positive Nodes in Patient With Sentinel Lymph Node-Positive Breast Cancer: A Nomogram Validation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unal, Bulent; Gur, Akif Serhat; Beriwal, Sushil

    2009-11-15

    Purpose: Katz suggested a nomogram for predicting having four or more positive nodes in sentinel lymph node (SLN)-positive breast cancer patients. The findings from this formula might influence adjuvant radiotherapy decisions. Our goal was to validate the accuracy of the Katz nomogram. Methods and Materials: We reviewed the records of 309 patients with breast cancer who had undergone completion axillary lymph node dissection. The factors associated with the likelihood of having four or more positive axillary nodes were evaluated in patients with one to three positive SLNs. The nomogram developed by Katz was applied to our data set. The areamore » under the curve of the corresponding receiver operating characteristics curve was calculated for the nomogram. Results: Of the 309 patients, 80 (25.9%) had four or more positive axillary lymph nodes. On multivariate analysis, the number of positive SLNs (p < .0001), overall metastasis size (p = .019), primary tumor size (p = .0001), and extracapsular extension (p = .01) were significant factors predicting for four or more positive nodes. For patients with <5% probability, 90.3% had fewer than four positive nodes and 9.7% had four or more positive nodes. The negative predictive value was 91.7%, and sensitivity was 80%. The nomogram was accurate and discriminating (area under the curve, .801). Conclusion: The probability of four or more involved nodes is significantly greater in patients who have an increased number of positive SLNs, increased overall metastasis size, increased tumor size, and extracapsular extension. The Katz nomogram was validated in our patients. This nomogram will be helpful to clinicians making adjuvant treatment recommendations to their patients.« less

  5. Agreement between BMI and body fat obesity definitions in a physically active population.

    PubMed

    Porto, Luiz Guilherme G; Nogueira, Rosenkranz M; Nogueira, Eugênio C; Molina, Guilherme E; Farioli, Andrea; Junqueira, Luiz Fernando; Kales, Stefanos N

    2016-01-01

    Body mass index (BMI) is a widely used proxy of body composition (BC). Concerns exist regarding possible BMI misclassification among active populations. We compared the prevalence of obesity as categorized by BMI or by skinfold estimates of body fat percentage (BF%) in a physically active population. 3,822 military firefighters underwent a physical fitness evaluation including cardiorespiratory fitness (CRF) by the 12 min-Cooper test, abdominal strength by sit-up test (SUT) and body composition (BC) by BF% (as the reference), as well as BMI. Obesity was defined by BF% > 25% and BMI ≥ 30 kg/m2. Agreement was evaluated by sensitivity and specificity of BMI, positive and negative predictive values (PPV/NPV), positive and negative likelihood (LR+/LR-), receiver operating characteristic (ROC) curves and also across age, CRF and SUT subgroups. The prevalence of obesity estimated by BMI (13.3%) was similar to BF% (15.9%). Overall agreement was high (85.8%) and varied in different subgroups (75.3-94.5%). BMI underestimated the prevalence of obesity in all categories with high specificity (≥ 81.2%) and low sensitivity (≤ 67.0). All indices were affected by CRF, age and SUT, with better sensitivity, NPV and LR- in the less fit and older groups; and higher specificity, PPV and LR+ among the fittest and youngest groups. ROC curves showed high area under the curve (≥ 0.77) except for subjects with CRF ≥ 14 METs (= 0.46). Both measures yielded similar obesity prevalences, with high agreement. BMI did not overestimate obesity prevalence. BMI ≥ 30 was highly specific to exclude obesity. Because of systematic under estimation, a lower BMI cut-off point might be considered in this population.

  6. Association of C-Reactive Protein With Bacterial and Respiratory Syncytial Virus-Associated Pneumonia Among Children Aged <5 Years in the PERCH Study.

    PubMed

    Higdon, Melissa M; Le, Tham; O'Brien, Katherine L; Murdoch, David R; Prosperi, Christine; Baggett, Henry C; Brooks, W Abdullah; Feikin, Daniel R; Hammitt, Laura L; Howie, Stephen R C; Kotloff, Karen L; Levine, Orin S; Scott, J Anthony G; Thea, Donald M; Awori, Juliet O; Baillie, Vicky L; Cascio, Stephanie; Chuananon, Somchai; DeLuca, Andrea N; Driscoll, Amanda J; Ebruke, Bernard E; Endtz, Hubert P; Kaewpan, Anek; Kahn, Geoff; Karani, Angela; Karron, Ruth A; Moore, David P; Park, Daniel E; Rahman, Mohammed Ziaur; Salaudeen, Rasheed; Seidenberg, Phil; Somwe, Somwe Wa; Sylla, Mamadou; Tapia, Milagritos D; Zeger, Scott L; Deloria Knoll, Maria; Madhi, Shabir A

    2017-06-15

    Lack of a gold standard for identifying bacterial and viral etiologies of pneumonia has limited evaluation of C-reactive protein (CRP) for identifying bacterial pneumonia. We evaluated the sensitivity and specificity of CRP for identifying bacterial vs respiratory syncytial virus (RSV) pneumonia in the Pneumonia Etiology Research for Child Health (PERCH) multicenter case-control study. We measured serum CRP levels in cases with World Health Organization-defined severe or very severe pneumonia and a subset of community controls. We evaluated the sensitivity and specificity of elevated CRP for "confirmed" bacterial pneumonia (positive blood culture or positive lung aspirate or pleural fluid culture or polymerase chain reaction [PCR]) compared to "RSV pneumonia" (nasopharyngeal/oropharyngeal or induced sputum PCR-positive without confirmed/suspected bacterial pneumonia). Receiver operating characteristic (ROC) curves were constructed to assess the performance of elevated CRP in distinguishing these cases. Among 601 human immunodeficiency virus (HIV)-negative tested controls, 3% had CRP ≥40 mg/L. Among 119 HIV-negative cases with confirmed bacterial pneumonia, 77% had CRP ≥40 mg/L compared with 17% of 556 RSV pneumonia cases. The ROC analysis produced an area under the curve of 0.87, indicating very good discrimination; a cut-point of 37.1 mg/L best discriminated confirmed bacterial pneumonia (sensitivity 77%) from RSV pneumonia (specificity 82%). CRP ≥100 mg/L substantially improved specificity over CRP ≥40 mg/L, though at a loss to sensitivity. Elevated CRP was positively associated with confirmed bacterial pneumonia and negatively associated with RSV pneumonia in PERCH. CRP may be useful for distinguishing bacterial from RSV-associated pneumonia, although its role in discriminating against other respiratory viral-associated pneumonia needs further study. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  7. Comparison of the diagnostic accuracy, sensitivity and specificity of four odontological methods for age evaluation in Italian children at the age threshold of 14 years using ROC curves.

    PubMed

    Pinchi, Vilma; Pradella, Francesco; Vitale, Giulia; Rugo, Dario; Nieri, Michele; Norelli, Gian-Aristide

    2016-01-01

    The age threshold of 14 years is relevant in Italy as the minimum age for criminal responsibility. It is of utmost importance to evaluate the diagnostic accuracy of every odontological method for age evaluation considering the sensitivity, or the ability to estimate the true positive cases, and the specificity, or the ability to estimate the true negative cases. The research aims to compare the specificity and sensitivity of four commonly adopted methods of dental age estimation - Demirjian, Haavikko, Willems and Cameriere - in a sample of Italian children aged between 11 and 16 years, with an age threshold of 14 years, using receiver operating characteristic curves and the area under the curve (AUC). In addition, new decision criteria are developed to increase the accuracy of the methods. Among the four odontological methods for age estimation adopted in the research, the Cameriere method showed the highest AUC in both female and male cohorts. The Cameriere method shows a high degree of accuracy at the age threshold of 14 years. To adopt the Cameriere method to estimate the 14-year age threshold more accurately, however, it is suggested - according to the Youden index - that the decision criterion be set at the lower value of 12.928 for females and 13.258 years for males, obtaining a sensitivity of 85% and specificity of 88% in females, and a sensitivity of 77% and specificity of 92% in males. If a specificity level >90% is needed, the cut-off point should be set at 12.959 years (82% sensitivity) for females. © The Author(s) 2015.

  8. The noninvasive mouse ear swelling assay. II. Testing the contact sensitizing potency of fragrances.

    PubMed

    Thorne, P S; Hawk, C; Kaliszewski, S D; Guiney, P D

    1991-11-01

    The noninvasive mouse ear swelling assay (MESA) for contact allergy testing was evaluated using fragrance components and complex fragrance mixtures. The test materials represented weak sensitizers and nonsensitizers. Two versions of the MESA were investigated. Both were noninvasive and utilized only topical abdominal dosing and ear challenge with single applications in BALB/cBy mice. The vit A MESA differed from the regular MESA only in that mice were maintained on a diet with 17-fold higher levels of vitamin A (vit A) acetate beginning 3 weeks prior to induction. Sensitization reactions were determined by measuring the mean increase in ear swelling over baseline at 24, 48 and 72 hr postexposure. Irritation dose-response curves facilitated choosing a high nonirritating challenge dose. Sensitization dose-response curves were developed for cinnamaldehyde (CINN) and a complex fragrance mixture, F-16. From these curves, the SD50 was determined. This value represents the dose which sensitized half the animals and serves to rank the potency of compounds for allergic contact dermatitis and to compare values among different assays. The SD50 for CINN was 21.6% while the SD50vit A for F-16 was 26.6%. The other fragrance, isoeugenol (ISOE), and fragrance mixtures, F-07 and F-22, were also found to be weak sensitizers in the MESA and vit A MESA. The results in the MESA for CINN and ISOE were in the range observed with guinea pig test protocols but showed that the MESA was more sensitive than human test protocols. Two of the fragrance mixtures tested in the MESA gave comparable results in the Buehler guinea pig assay. However, the third (F-22) was negative in the Buehler assay and the MESA, but positive in the vit A MESA. The results of this work with weak sensitizers and the companion study (Thorne et al., 1991) with potent sensitizers at low doses illustrate that the noninvasive MESA is as sensitive as many standard guinea pig assays. In addition, it is easier and much less expensive to perform. The vit A MESA has the sensitivity and predictive power needed to test compounds and mixtures for contact sensitizing potency.

  9. Improvement of immunoassay detection system by using alternating current magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Kawabata, R.; Mizoguchi, T.; Kandori, A.

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  10. Improvement of immunoassay detection system by using alternating current magnetic susceptibility.

    PubMed

    Kawabata, R; Mizoguchi, T; Kandori, A

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  11. Contrast enhanced ultrasound and magnetic resonance imaging in hepatocellular carcinoma diagnosis.

    PubMed

    Dumitrescu, Cristiana I; Gheonea, Ioana A; Săndulescu, Larisa; Surlin, Valeriu; Săftoiu, Adrian; Dumitrescu, Daniela

    2013-12-01

    The new developments in imaging technology, including contrast enhanced ultrasound (CEUS), computed tomography (CT), and magnetic resonance imaging (MRI), allow a better diagnosis of both malignant and benign liver lesions. A retrospective trial of 126 patients was conducted in the Gastroenterology and Imaging Departments of the University of Medicine and Pharmacy Craiova, Romania. CEUS and MRI were the imaging techniques used for diagnosis of focal liver lesions (FLL), especially for hepatocellular carcinoma (HCC). Histopathology was used only in 15 cases. For each method of investigation we calculated the sensitivity, specificity, positive and negative predictive values (PPV and NPV), positive and negative likelihood ratio (+LR, -LR), accuracy and we compared the ROC curves. Statistical analysis also included the Chi-square and Kappa tests. Seventy six cases were diagnosed as HCC, with average size of 5.2±3.3 cm in diameter. The sensitivity and specificity were 71.4% and 95.6% for CEUS and 91.4%, 98.9% respectively, for MRI. When comparing the ROC curves, we found a higher area under curve for MRI (0.952) then for CEUS (0.835) (p=0.005), and 95% confidence interval of 0.0343 to 0.199. No statistically significant difference in diagnosis of FLL was found between CEUS and MRI (p > 0.05) and the agreement between the two imaging techniques was good (k = 0.78). CEUS can be used as the first step in the diagnosis of liver lesions, but MRI remains the gold standard diagnostic method for liver tumors.

  12. Magnetophoretic induction of curvature in coleoptiles and hypocotyls

    NASA Technical Reports Server (NTRS)

    Kuznetsov, O. A.; Hasenstein, K. H.

    1997-01-01

    Coleoptiles of barley (Hordeum vulgare) were positioned in a high gradient magnetic field (HGMF, dynamic factor gradient of H(2)/2 of 10(9)-10(10) Oe2 cm-1), generated by a ferromagnetic wedge in a uniform magnetic field and rotated on a 1 rpm clinostat. After 4 h 90% of coleoptiles had curved toward the HGMF. The cells affected by HGMF showed clear intracellular displacement of amyloplasts. Coleoptiles in a magnetic field next to a non-ferromagnetic wedge showed no preferential curvature. The small size of the area of nonuniformity of the HGMF allowed mapping of the sensitivity of the coleoptiles by varying the initial position of the wedge relative to the coleoptile apex. When the ferromagnetic wedge was placed 1 mm below the coleoptile tip only 58% of the coleoptiles curved toward the wedge indicating that the cells most sensitive to intracellular displacement of amyloplasts and thus gravity sensing are confined to the top 1 mm portion of barley coleoptiles. Similar experiments with tomato hypocotyls (Lycopersicum esculentum) also resulted in curvature toward the HGMF. The data strongly support the amyloplast-based gravity-sensing system in higher plants and the usefulness of HGMF to substitute gravity in shoots.

  13. [Waist-to-height ratio is an indicator of metabolic risk in children].

    PubMed

    Valle-Leal, Jaime; Abundis-Castro, Leticia; Hernández-Escareño, Juan; Flores-Rubio, Salvador

    2016-01-01

    Abdominal fat, particularly visceral, is associated with a high risk of metabolic complications. The waist-height ratio (WHtR) is used to assess abdominal fat in individuals of all ages. To determine the ability of the waist-to-height ratio to detect metabolic risk in mexican schoolchildren. A study was conducted on children between 6 and 12 years. Obesity was diagnosed as a body mass index (BMI) ≥ 85th percentile, and an ICE ≥0.5 was considered abdominal obesity. Blood levels of glucose, cholesterol and triglycerides were measured. The sensitivity, specificity, positive predictive and negative value, area under curve, the positive likelihood ratio and negative likelihood ratio of the WHtR and BMI were calculated in order to identify metabolic alterations. WHtR and BMI were compared to determine which had the best diagnostic efficiency. Of the 223 children included in the study, 51 had hypertriglyceridaemia, 27 with hypercholesterolaemia, and 9 with hyperglycaemia. On comparing the diagnostic efficiency of WHtR with that of BMI, there was a sensitivity of 100% vs. 56% for hyperglycaemia, 93 vs. 70% for cholesterol, and 76 vs. 59% for hypertriglyceridaemia. The specificity, negative predictive value, positive predictive value, positive likelihood ratio, negative likelihood ratio, and area under curve were also higher for WHtR. The WHtR is a more efficient indicator than BMI in identifying metabolic risk in mexican school-age. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.

    PubMed

    Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem

    2014-08-01

    The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.

  15. Comparison between presepsin and procalcitonin in early diagnosis of neonatal sepsis.

    PubMed

    Iskandar, Agustin; Arthamin, Maimun Z; Indriana, Kristin; Anshory, Muhammad; Hur, Mina; Di Somma, Salvatore

    2018-05-09

    Neonatal sepsis remains worldwide one of the leading causes of morbidity and mortality in both term and preterm infants. Lower mortality rates are related to timely diagnostic evaluation and prompt initiation of empiric antibiotic therapy. Blood culture, as gold standard examination for sepsis, has several limitations for early diagnosis, so that sepsis biomarkers could play an important role in this regard. This study was aimed to compare the value of the two biomarkers presepsin and procalcitonin in early diagnosis of neonatal sepsis. This was a prospective cross-sectional study performed, in Saiful Anwar General Hospital Malang, Indonesia, in 51 neonates that fulfill the criteria of systemic inflammatory response syndrome (SIRS) with blood culture as diagnostic gold standard for sepsis. At reviewer operating characteristic (ROC) curve analyses, using a presepsin cutoff of 706,5 pg/mL, the obtained area under the curve (AUCs) were: sensitivity = 85.7%, specificity = 68.8%, positive predictive value = 85.7%, negative predictive value = 68.8%, positive likelihood ratio = 2.75, negative likelihood ratio = 0.21, and accuracy = 80.4%. On the other hand, with a procalcitonin cutoff value of 161.33 pg/mL the obtained AUCs showed: sensitivity = 68.6%, specificity = 62.5%, positive predictive value = 80%, negative predictive value = 47.6%, positive likelihood ratio = 1.83, the odds ratio negative = 0.5, and accuracy = 66.7%. In early diagnosis of neonatal sepsis, compared with procalcitonin, presepsin seems to provide better early diagnostic value with consequent possible faster therapeutical decision making and possible positive impact on outcome of neonates.

  16. Linguistic adaptation, validation and comparison of 3 routinely used neuropathic pain questionnaires.

    PubMed

    Li, Jun; Feng, Yi; Han, Jisheng; Fan, Bifa; Wu, Dasheng; Zhang, Daying; Du, Dongping; Li, Hui; Lim, Jian; Wang, Jiashuang; Jin, Yi; Fu, Zhijian

    2012-01-01

    Neuropathic pain questionnaires are efficient diagnostic tools for neuropathic pain and play an important role in neuropathic pain epidemiologic studies in China. No comparison data was available in regards to the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS), the Neuropathic Pain Questionnaire (NPQ) and ID Pain within and among the same population. To achieve a linguistic adaptation, validation, and comparison of Chinese versions of the 3 neuropathic pain questionnaires (LANSS, NPQ and ID Pain). A nonrandomized, controlled, prospective, multicenter trial. Ten pain centers in China. Two forward translations followed by comparison and reconciliation of the translations. Comparison of the 2 backward translations with the original version was made to establish consistency and accuracy of the translations. Pilot testing and pain specialists' evaluations were also required. A total of 140 patients were enrolled in 10 centers throughout China: 70 neuropathic pain patients and 70 nociceptive pain patients. Reliability (Cronbach's alpha coefficients and Guttman split-half coefficients) and validity (sensitivity, specificity, positive and negative predictive values, receiver operating characteristic [ROC] curves and the area under the ROC curves) of the 3 questionnaires were determined. ROC curves and the area under the ROC curves of the 3 questionnaires were also compared. Chinese versions of LANSS, NPQ and ID Pain had a good reliability (Cronbach's alpha coefficients and Guttman split-half coefficients were greater than 0.7). Sensitivity, specificity, positive and negative predictive values of the Chinese versions of LANSS and ID Pain were considerably high ( > 80%). The area under the ROC curves of LANSS and ID Pain was significantly higher than that of NPQ (P < 0.05). There was no statistically significant difference between the area under the ROC curves of LANSS and ID Pain (P > 0.05). The study was based on patients with a high school degree or above, which limited the application of the 3 neuropathic pain questionnaires to patients with lower educational levels. The Chinese versions of LANSS and ID Pain developed and validated by this study can be used as a diagnostic tool in differentiating neuropathic pain in patients whose native language is Chinese (Mandarin).

  17. Test of prototype ITER vacuum ultraviolet spectrometer and its application to impurity study in KSTAR plasmas.

    PubMed

    Seon, C R; Hong, J H; Jang, J; Lee, S H; Choe, W; Lee, H H; Cheon, M S; Pak, S; Lee, H G; Biel, W; Barnsley, R

    2014-11-01

    To optimize the design of ITER vacuum ultraviolet (VUV) spectrometer, a prototype VUV spectrometer was developed. The sensitivity calibration curve of the spectrometer was calculated from the mirror reflectivity, the grating efficiency, and the detector efficiency. The calibration curve was consistent with the calibration points derived in the experiment using the calibrated hollow cathode lamp. For the application of the prototype ITER VUV spectrometer, the prototype spectrometer was installed at KSTAR, and various impurity emission lines could be measured. By analyzing about 100 shots, strong positive correlation between the O VI and the C IV emission intensities could be found.

  18. Sensitivity curves for searches for gravitational-wave backgrounds

    NASA Astrophysics Data System (ADS)

    Thrane, Eric; Romano, Joseph D.

    2013-12-01

    We propose a graphical representation of detector sensitivity curves for stochastic gravitational-wave backgrounds that takes into account the increase in sensitivity that comes from integrating over frequency in addition to integrating over time. This method is valid for backgrounds that have a power-law spectrum in the analysis band. We call these graphs “power-law integrated curves.” For simplicity, we consider cross-correlation searches for unpolarized and isotropic stochastic backgrounds using two or more detectors. We apply our method to construct power-law integrated sensitivity curves for second-generation ground-based detectors such as Advanced LIGO, space-based detectors such as LISA and the Big Bang Observer, and timing residuals from a pulsar timing array. The code used to produce these plots is available at https://dcc.ligo.org/LIGO-P1300115/public for researchers interested in constructing similar sensitivity curves.

  19. A Transient Dopamine Signal Represents Avoidance Value and Causally Influences the Demand to Avoid

    PubMed Central

    Pultorak, Katherine J.; Schelp, Scott A.; Isaacs, Dominic P.; Krzystyniak, Gregory

    2018-01-01

    Abstract While an extensive literature supports the notion that mesocorticolimbic dopamine plays a role in negative reinforcement, recent evidence suggests that dopamine exclusively encodes the value of positive reinforcement. In the present study, we employed a behavioral economics approach to investigate whether dopamine plays a role in the valuation of negative reinforcement. Using rats as subjects, we first applied fast-scan cyclic voltammetry (FSCV) to determine that dopamine concentration decreases with the number of lever presses required to avoid electrical footshock (i.e., the economic price of avoidance). Analysis of the rate of decay of avoidance demand curves, which depict an inverse relationship between avoidance and increasing price, allows for inference of the worth an animal places on avoidance outcomes. Rapidly decaying demand curves indicate increased price sensitivity, or low worth placed on avoidance outcomes, while slow rates of decay indicate reduced price sensitivity, or greater worth placed on avoidance outcomes. We therefore used optogenetics to assess how inducing dopamine release causally modifies the demand to avoid electrical footshock in an economic setting. Increasing release at an avoidance predictive cue made animals more sensitive to price, consistent with a negative reward prediction error (i.e., the animal perceives they received a worse outcome than expected). Increasing release at avoidance made animals less sensitive to price, consistent with a positive reward prediction error (i.e., the animal perceives they received a better outcome than expected). These data demonstrate that transient dopamine release events represent the value of avoidance outcomes and can predictably modify the demand to avoid. PMID:29766047

  20. Comparison of a serum indirect fluorescent antibody test with two Western blot tests for the diagnosis of equine protozoal myeloencephalitis.

    PubMed

    Duarte, Paulo C; Daft, Barbara M; Conrad, Patricia A; Packham, Andrea E; Gardner, Ian A

    2003-01-01

    A serum indirect fluorescent antibody test (IFAT) was compared with a Western blot (WB) and a modified Western blot (mWB) for diagnosis of equine protozoal myeloencephalitis (EPM). Using receiver-operating characteristic (ROC) analysis, the area under the curve of the IFAT was greater than the areaunder the curves of the WB and the mWB (P = 0.025 and P = 0.044, respectively). There was no statistically significant difference between the areas under the curves of the WBs (P > 0.05). On the basis of an arbitrarily chosen cut-off titer for a positive test result of 1:80 for the IFAT and interpreting weak positive WB results as positive test results, the sensitivities and 95% confidence intervals (CI) of all 3 tests were identical and equal to 88.9% (51.8-99.7%). The specificities and 95% CIs of the IFAT, WB, and mWB test were 100% (91-100%), 87.2% (72.6-95.7%), and 69.2% (52.4-83%), respectively. The overall accuracy of the IFAT was shown to be better than that of the WBs and, therefore, the test has potential for use in the diagnosis of EPM caused by Sarcocystis neurona.

  1. Optimal threshold estimation for binary classifiers using game theory.

    PubMed

    Sanchez, Ignacio Enrique

    2016-01-01

    Many bioinformatics algorithms can be understood as binary classifiers. They are usually compared using the area under the receiver operating characteristic ( ROC ) curve. On the other hand, choosing the best threshold for practical use is a complex task, due to uncertain and context-dependent skews in the abundance of positives in nature and in the yields/costs for correct/incorrect classification. We argue that considering a classifier as a player in a zero-sum game allows us to use the minimax principle from game theory to determine the optimal operating point. The proposed classifier threshold corresponds to the intersection between the ROC curve and the descending diagonal in ROC space and yields a minimax accuracy of 1-FPR. Our proposal can be readily implemented in practice, and reveals that the empirical condition for threshold estimation of "specificity equals sensitivity" maximizes robustness against uncertainties in the abundance of positives in nature and classification costs.

  2. Oxidation of methionine 216 in sheep and elk prion protein is highly dependent upon the amino acid at position 218 but is not important for prion propagation

    USDA-ARS?s Scientific Manuscript database

    We developed a sensitive mass spectrometry-based method of quantitating the prions present in elk and sheep. Calibration curves relating the area ratios of the selected analyte peptides and their homologous stable isotope labeled internal standards were prepared. This method was compared to the ELIS...

  3. Contribution of Kinetic Characteristics of Axillary Lymph Nodes to the Diagnosis in Breast Magnetic Resonance Imaging

    PubMed Central

    Örgüç, Şebnem; Başara, Işıl; Pekindil, Gökhan; Coşkun, Teoman

    2012-01-01

    Objective: To assess the contribution of kinetic characteristics in the discrimination of malignant-benign axillary lymph nodes. Material and Methods: One hundred fifty-five female patients were included in the study. Following magnetic resonance imaging (MRI) examinations postprocessing applications were applied, dynamic curves were obtained from subtracted images. Types of dynamic curves were correlated with histopathological results in malignant cases or final clinical results in patients with no evidence of malignancy. Sensitivity, specificity, positive likehood ratio (+LHR), negative (−LHR) of dynamic curves characterizing the axillary lymph nodes were calculated. Results: A total of 178 lymph nodes greater than 8 mm were evaluated in 113 patients. Forty-six lymph nodes in 24 cases had malignant axillary involvement. 132 lymph nodes in 89 patients with benign diagnosis were included in the study. The sensitivity of type 3 curve as an indicator of malignancy was calculated as 89%. However the specificity, +LHR, −LHR were calculated as 14%, 1.04, 0.76 respectively. Conclusion: Since kinetic analysis of both benign and malignant axillary lymph nodes, rapid enhancement and washout (type 3) they cannot be used as a discriminator, unlike breast lesions. MRI, depending on the kinetic features of the axillary lymph nodes, is not high enough to be used in the clinical management of breast cancer patients. PMID:25207016

  4. Evaluating the predictive accuracy and the clinical benefit of a nomogram aimed to predict survival in node-positive prostate cancer patients: External validation on a multi-institutional database.

    PubMed

    Bianchi, Lorenzo; Schiavina, Riccardo; Borghesi, Marco; Bianchi, Federico Mineo; Briganti, Alberto; Carini, Marco; Terrone, Carlo; Mottrie, Alex; Gacci, Mauro; Gontero, Paolo; Imbimbo, Ciro; Marchioro, Giansilvio; Milanese, Giulio; Mirone, Vincenzo; Montorsi, Francesco; Morgia, Giuseppe; Novara, Giacomo; Porreca, Angelo; Volpe, Alessandro; Brunocilla, Eugenio

    2018-04-06

    To assess the predictive accuracy and the clinical value of a recent nomogram predicting cancer-specific mortality-free survival after surgery in pN1 prostate cancer patients through an external validation. We evaluated 518 prostate cancer patients treated with radical prostatectomy and pelvic lymph node dissection with evidence of nodal metastases at final pathology, at 10 tertiary centers. External validation was carried out using regression coefficients of the previously published nomogram. The performance characteristics of the model were assessed by quantifying predictive accuracy, according to the area under the curve in the receiver operating characteristic curve and model calibration. Furthermore, we systematically analyzed the specificity, sensitivity, positive predictive value and negative predictive value for each nomogram-derived probability cut-off. Finally, we implemented decision curve analysis, in order to quantify the nomogram's clinical value in routine practice. External validation showed inferior predictive accuracy as referred to in the internal validation (65.8% vs 83.3%, respectively). The discrimination (area under the curve) of the multivariable model was 66.7% (95% CI 60.1-73.0%) by testing with receiver operating characteristic curve analysis. The calibration plot showed an overestimation throughout the range of predicted cancer-specific mortality-free survival rates probabilities. However, in decision curve analysis, the nomogram's use showed a net benefit when compared with the scenarios of treating all patients or none. In an external setting, the nomogram showed inferior predictive accuracy and suboptimal calibration characteristics as compared to that reported in the original population. However, decision curve analysis showed a clinical net benefit, suggesting a clinical implication to correctly manage pN1 prostate cancer patients after surgery. © 2018 The Japanese Urological Association.

  5. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    PubMed

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P <0.001). Receiver operating characteristic curve revealed that in paroxysmal AF and non-AF subjects, AF-positive readings at 26% during 24-hour ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P <0.01) for detecting paroxysmal AF. These findings suggest that in elderly hypertensives, a novel 24-hour ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  6. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    PubMed

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  7. Can hip abduction and external rotation discriminate sacroiliac joint pain?

    PubMed

    Adhia, Divya Bharatkumar; Tumilty, Steve; Mani, Ramakrishnan; Milosavljevic, Stephan; Bussey, Melanie D

    2016-02-01

    The primary aim of the study is to determine if Hip Abduction and External Rotation (HABER) test is capable of reproducing familiar pain in individuals with low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive) when compared with LBP of Non-SIJ origin (SIJ-negative). If so, the secondary aim is to determine the diagnostic accuracy of HABER test against the reference standard of pain provocation tests, and to determine which increments of the HABER test has highest sensitivity and specificity for identifying SIJ-positive individuals. Single-blinded diagnostic accuracy study. Participants [n(122)] between ages of 18-50 y, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)], based on reference standard of pain provocation tests [≥3 positive tests = SIJ-positive]. Another musculoskeletal physiotherapist, blinded to clinical groups, evaluated participants for reproduction of familiar pain during each increment (10°, 20°, 30°, 40°, and 50°) of HABER test. The HABER test reproduced familiar pain in SIJ-positive individuals when compared with SIJ-negative individuals [p (0.001), R(2) (0.38), Exp(β) (5.95-10.32)], and demonstrated moderate level of sensitivity (67%-78%) and specificity (71%-72%) for identifying SIJ-positive individuals. Receiver operator curve analysis demonstrated that the HABER increments of ≥30° have the highest sensitivity (83%-100%) and specificity (52%-64%). The HABER test is capable of reproducing familiar pain in SIJ-positive LBP individuals and has moderate levels of sensitivity and specificity for identifying SIJ-positive LBP individuals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Diagnosis of adrenal insufficiency.

    PubMed

    Dorin, Richard I; Qualls, Clifford R; Crapo, Lawrence M

    2003-08-05

    The cosyntropin stimulation test is the initial endocrine evaluation of suspected primary or secondary adrenal insufficiency. To critically review the utility of the cosyntropin stimulation test for evaluating adrenal insufficiency. The MEDLINE database was searched from 1966 to 2002 for all English-language papers related to the diagnosis of adrenal insufficiency. Studies with fewer than 5 persons with primary or secondary adrenal insufficiency or with fewer than 10 persons as normal controls were excluded. For secondary adrenal insufficiency, only studies that stratified participants by integrated tests of adrenal function were included. Summary receiver-operating characteristic (ROC) curves were generated from all studies that provided sensitivity and specificity data for 250-microg and 1-microg cosyntropin tests; these curves were then compared by using area under the curve (AUC) methods. All estimated values are given with 95% CIs. At a specificity of 95%, sensitivities were 97%, 57%, and 61% for summary ROC curves in tests for primary adrenal insufficiency (250-microg cosyntropin test), secondary adrenal insufficiency (250-microg cosyntropin test), and secondary adrenal insufficiency (1-microg cosyntropin test), respectively. The area under the curve for primary adrenal insufficiency was significantly greater than the AUC for secondary adrenal insufficiency for the high-dose cosyntropin test (P < 0.001), but AUCs for the 250-microg and 1-microg cosyntropin tests did not differ significantly (P > 0.5) for secondary adrenal insufficiency. At a specificity of 95%, summary ROC analysis for the 250-microg cosyntropin test yielded a positive likelihood ratio of 11.5 (95% CI, 8.7 to 14.2) and a negative likelihood ratio of 0.45 (CI, 0.30 to 0.60) for the diagnosis of secondary adrenal insufficiency. Cortisol response to cosyntropin varies considerably among healthy persons. The cosyntropin test performs well in patients with primary adrenal insufficiency, but the lower sensitivity in patients with secondary adrenal insufficiency necessitates use of tests involving stimulation of the hypothalamus if the pretest probability is sufficiently high. The operating characteristics of the 250-microg and 1-microg cosyntropin tests are similar.

  9. Effect of annealing temperature and dopant concentration on the thermoluminescence sensitivity in LiF:Mg,Cu,Ag material.

    PubMed

    Yahyaabadi, Akram; Torkzadeh, Falamarz; Rezaei Ochbelagh, Dariush; Hosseini Pooya, Seyed Mahdi

    2018-04-24

    LiF:Mg,Cu,Ag is a new dosimetry material that is similar to LiF:Mg,Cu,P in terms of dosimetric properties. The effect of the annealing temperature in the range of 200 to 350°C on the thermoluminescence (TL) sensitivity and the glow curve structure of this material at different concentrations of silver (Ag) was investigated. It has been demonstrated that the optimum values of the annealing temperature and the Ag concentration are 240°C and 0.1 mol% for better sensitivity, respectively. The TL intensity decreases at annealing temperatures lower than 240°C or higher than 240°C, reaching a minimum at 300°C and then again increases for various Ag concentrations. It was observed that the glow curve structure altered and the area under the low temperature peak as well as the area under the main dosimetric peak decreased with increasing annealing temperature. The position of the main dosimetric peak moved in the direction of higher temperatures, but at 320 and 350°C annealing temperatures, it shifted to lower temperatures. It was also observed that the TL sensitivity could partially be recovered by a combined annealing procedure. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Developing a clinical utility framework to evaluate prediction models in radiogenomics

    NASA Astrophysics Data System (ADS)

    Wu, Yirong; Liu, Jie; Munoz del Rio, Alejandro; Page, David C.; Alagoz, Oguzhan; Peissig, Peggy; Onitilo, Adedayo A.; Burnside, Elizabeth S.

    2015-03-01

    Combining imaging and genetic information to predict disease presence and behavior is being codified into an emerging discipline called "radiogenomics." Optimal evaluation methodologies for radiogenomics techniques have not been established. We aim to develop a clinical decision framework based on utility analysis to assess prediction models for breast cancer. Our data comes from a retrospective case-control study, collecting Gail model risk factors, genetic variants (single nucleotide polymorphisms-SNPs), and mammographic features in Breast Imaging Reporting and Data System (BI-RADS) lexicon. We first constructed three logistic regression models built on different sets of predictive features: (1) Gail, (2) Gail+SNP, and (3) Gail+SNP+BI-RADS. Then, we generated ROC curves for three models. After we assigned utility values for each category of findings (true negative, false positive, false negative and true positive), we pursued optimal operating points on ROC curves to achieve maximum expected utility (MEU) of breast cancer diagnosis. We used McNemar's test to compare the predictive performance of the three models. We found that SNPs and BI-RADS features augmented the baseline Gail model in terms of the area under ROC curve (AUC) and MEU. SNPs improved sensitivity of the Gail model (0.276 vs. 0.147) and reduced specificity (0.855 vs. 0.912). When additional mammographic features were added, sensitivity increased to 0.457 and specificity to 0.872. SNPs and mammographic features played a significant role in breast cancer risk estimation (p-value < 0.001). Our decision framework comprising utility analysis and McNemar's test provides a novel framework to evaluate prediction models in the realm of radiogenomics.

  11. A novel clinical index for the assessment of RVD in acute pulmonary embolism: Blood pressure index.

    PubMed

    Ates, Hale; Ates, Ihsan; Kundi, Harun; Arikan, Mehmet Fettah; Yilmaz, Fatma Meric

    2017-10-01

    This study aims to investigate the role of the blood pressure index (BPI), which is a new index that we developed, in detection of right ventricular dysfunction (RVD) in acute pulmonary embolism (APE). A total of 539 patients, (253 males and 286 females), diagnosed with APE using computer tomography pulmonary angiography were included in the study. The BPI was obtained by dividing systolic blood pressure (SBP) by diastolic blood pressure (DBP). Mean DBP (75±11mmHg vs 63±15mmHg; p<0.001, respectively) was found to be higher in RVD patients compared to those without RVD, whereas BPI (1.5±0.1 vs 1.9±0.2; p<0.001, respectively) was lower. Examining the performance of BPI in prediction of RVD using receiver operating characteristic curve analysis (area under curve±SE=0.975±0.006; p<0.001), it was found that BPI could predict RVD with very high sensitivity (92.8%) and specificity (100%) and had a positive predictive value of 100% and a negative predictive value of 42.1%. According to the analysis, the highest youden index for the optimal prediction value was found to be 0.478 and the BPI≤1.4 was found to predict mortality 68.6% sensitivity and 80.8% specificity (Area under curve±SE=0.777±0.051; p<0.001). We found that BPI was an index with high positive predictive value and low negative predictive value in detection of RVD. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Anxiety and Depression Screening for Youth in a Primary Care Population

    PubMed Central

    Katon, Wayne; Joan, Russo; Richardson, Laura; McCauley, Elizabeth; Lozano, Paula

    2008-01-01

    Objective Prior studies have shown a low rate of accurate identification by primary care physicians of mental health disorders in youth. This study tested the psychometric properties of two brief mental health screening questionnaires, the Mood and Feelings Questionnaire – Short Form (MFQ-SF) and Childhood Anxiety Sensitivity Index (ASI), in a large sample of youth. Methods In a sample of 1375 youth age 11 to 17 (779 with asthma, 596 randomly selected controls) enrolled in an HMO, the psychometric properties (optimum cutoffs on Receiver Operating Curve (ROC) curves, sensitivity, specificity, positive and negative predictive values) of two brief anxiety and depression screens were examined versus a “gold standard” structured psychiatric interview. Results Both the MFQ-SF and ASI performed well on ROC analysis for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better on ROC analysis than the ASI for youth with major depression (area under the curve of 0.84 vs 0.77). For screening youth with anxiety disorders ROC curves showed that both the MFQ-SF and ASI only performed in the fair range (area under the curve of 0.76). Conclusion The MFQ-SF and ASI are two relatively brief questionnaires that performed well for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better than the ASI for screening youth with major depression. Use of these instruments could increase the accuracy of identification of mental health disorders in youth by primary care physicians. PMID:18501865

  13. Significance of combined detection of JAK2V617F, MPL and CALR gene mutations in patients with essential thrombocythemia

    PubMed Central

    Ji, Liying; Qian, Mengyao; Wu, Nana; Wu, Jianmin

    2017-01-01

    The aim of this study was to analyze the mutation rate of JAK2V617F, MPLW515L/K and CALR genes in adult patients with essential thrombocythemia (ET) and the accuracy of the combined detection by the receiver operating curve. Three hundred and forty-two cases with high-platelets (≥300×109/l) were consecutively selected. The patients were analyzed for routine blood examination, bone marrow biopsy and genetic testing. One hundred and fifty-four cases (45.03%) were diagnosed with ET and 188 cases of secondary thrombocythemia according to the hematopoietic and lymphoid tissue tumor classification standards of 2008. It was found that the mutant type of three genes showed three bands, whereas only one band for wild-type. The JAK2V617F and MPL mutations did not cause a change in the open reading frame and the CALR mutation resulted in its change. The mutation rate of JAK2V617F and CALR in ET group was significantly higher than that in the secondary thrombocythemia group (p<0.05). The positive mutation rate of MPL was only 4.55%. JAK2V617F-positive mutation alone was used to diagnose with ET. The area under the curve (AUC) was 0.721. The sensitivity was 72.4%, the specificity was 79.5% and the cut-off value was 0.25. When CALR-positive mutation alone was used to diagnose ET, the AUC, sensitivity, specificity and cut-off value were 0.664, 68.4, 82.4 and 0.09%, respectively. JAK2V617F combined with CALR mutation were used for diagnosis of ET. The AUC was 0.862, the sensitivity was 85.9%, the specificity was 87.8%, and the cut-off values were 0.21 and 0.07. In conclusion, the positive mutation rate of JAK2V617F and CALR in ET was higher, and the sensitivity, specificity and accuracy of the diagnosis of ET were significantly improved using the detection of JAK2V617F and CALR. PMID:28450924

  14. Significance of combined detection of JAK2V617F, MPL and CALR gene mutations in patients with essential thrombocythemia.

    PubMed

    Ji, Liying; Qian, Mengyao; Wu, Nana; Wu, Jianmin

    2017-03-01

    The aim of this study was to analyze the mutation rate of JAK2V617F, MPLW515L/K and CALR genes in adult patients with essential thrombocythemia (ET) and the accuracy of the combined detection by the receiver operating curve. Three hundred and forty-two cases with high-platelets (≥300×10 9 /l) were consecutively selected. The patients were analyzed for routine blood examination, bone marrow biopsy and genetic testing. One hundred and fifty-four cases (45.03%) were diagnosed with ET and 188 cases of secondary thrombocythemia according to the hematopoietic and lymphoid tissue tumor classification standards of 2008. It was found that the mutant type of three genes showed three bands, whereas only one band for wild-type. The JAK2V617F and MPL mutations did not cause a change in the open reading frame and the CALR mutation resulted in its change. The mutation rate of JAK2V617F and CALR in ET group was significantly higher than that in the secondary thrombocythemia group (p<0.05). The positive mutation rate of MPL was only 4.55%. JAK2V617F-positive mutation alone was used to diagnose with ET. The area under the curve (AUC) was 0.721. The sensitivity was 72.4%, the specificity was 79.5% and the cut-off value was 0.25. When CALR-positive mutation alone was used to diagnose ET, the AUC, sensitivity, specificity and cut-off value were 0.664, 68.4, 82.4 and 0.09%, respectively. JAK2V617F combined with CALR mutation were used for diagnosis of ET. The AUC was 0.862, the sensitivity was 85.9%, the specificity was 87.8%, and the cut-off values were 0.21 and 0.07. In conclusion, the positive mutation rate of JAK2V617F and CALR in ET was higher, and the sensitivity, specificity and accuracy of the diagnosis of ET were significantly improved using the detection of JAK2V617F and CALR.

  15. Sensitivity and Specificity of 50% Excess Weight Loss (50%EWL) and Twelve Other Bariatric Criteria for Weight Loss Success.

    PubMed

    van de Laar, Arnold W; van Rijswijk, A S; Kakar, H; Bruin, S C

    2018-02-27

    Criteria for bariatric weight loss success are numerous. Most of them are arbitrary. None of them is evidence-based. Our objective was to determine their sensitivity and specificity. Thirteen common bariatric weight loss criteria were compared to a benchmark reflecting the gold standard in bariatric surgery. We used an elaborate baseline BMI-independent weight loss percentile chart, based on retrospective data after laparoscopic Roux-en-Y gastric bypass (LRYGB), performed between 2007 and 2017. Percentile curves p31.6 (patients' expectation), p25 (interquartile range), p15.9 (1 standard deviation (SD) below median), and p10.9 (surgeons' goal) were used as possible cutoff for success to determine true or false positive and negative results beyond 1 year. We operated 4497 primary LRYGB patients, with mean follow-up 22 (± 1 SD 19; range 0-109) months, 3031 patients with last result ≥ 1 year, 518 ≥ 5 years. For all four cutoff percentile curves for success, specificities were low (2-72%) for criteria < 35 body mass index (BMI), ≥ 25percentage excess BMI loss (%EBMIL), ≥ 50%EBMIL, ≥ 15 percentage total weight loss (%TWL), ≥ 20%TWL, ≥ 25 percentage excess weight loss (%EWL), and high (83-96%) for < 30 BMI. No criterion had > 80% specificity and sensitivity for a cutoff above p15.9. For p15.9, they were both > 80% for criteria ≥ 10 BMI reduction and ≥ 50%EWL, both > 90% for ≥ 25%TWL and ≥ 35 percentage alterable weight loss (%AWL). All criteria had high sensitivities for all cutoff percentile curves (87-100%), except < 30 BMI (65-78%). For the first time, common bariatric criteria for weight loss success were systematically validated. Most criteria recognized success very well (high sensitivities), but ≥ 15%TWL, ≥ 20%TWL, < 35BMI, ≥ 25%EWL, ≥ 25%EBMIL, and ≥ 50%EBMIL left too many poor responders unnoticed (low specificities). Bariatric weight loss success is best assessed by comparing results to percentile curve 1 SD below median (p15.9) in a bariatric baseline BMI-independent weight loss percentile chart. Criteria ≥ 35%AWL and ≥ 25%TWL came close to that curve, both with > 90% sensitivity and specificity. Among others, criterion ≥ 50%EBMIL did not.

  16. Non-sky-averaged sensitivity curves for space-based gravitational-wave observatories

    NASA Astrophysics Data System (ADS)

    Vallisneri, Michele; Galley, Chad R.

    2012-06-01

    The signal-to-noise ratio (SNR) is used in gravitational-wave observations as the basic figure of merit for detection confidence and, together with the Fisher matrix, for the amount of physical information that can be extracted from a detected signal. SNRs are usually computed from a sensitivity curve, which describes the gravitational-wave amplitude needed by a monochromatic source of given frequency to achieve a threshold SNR. Although the term ‘sensitivity’ is used loosely to refer to the detector’s noise spectral density, the two quantities are not the same: the sensitivity includes also the frequency- and orientation-dependent response of the detector to gravitational waves and takes into account the duration of observation. For interferometric space-based detectors similar to LISA, which are sensitive to long-lived signals and have constantly changing position and orientation, exact SNRs need to be computed on a source-by-source basis. For convenience, most authors prefer to work with sky-averaged sensitivities, accepting inaccurate SNRs for individual sources and giving up control over the statistical distribution of SNRs for source populations. In this paper, we describe a straightforward end-to-end recipe to compute the non-sky-averaged sensitivity of interferometric space-based detectors of any geometry. This recipe includes the effects of spacecraft motion and of seasonal variations in the partially subtracted confusion foreground from Galactic binaries, and it can be used to generate a sampling distribution of sensitivities for a given source population. In effect, we derive error bars for the sky-averaged sensitivity curve, which provide a stringent statistical interpretation for previously unqualified statements about sky-averaged SNRs. As a worked-out example, we consider isotropic and Galactic-disk populations of monochromatic sources, as observed with the ‘classic LISA’ configuration. We confirm that the (standard) inverse-rms average sensitivity for the isotropic population remains the same whether or not the LISA orbits are included in the computation. However, detector motion tightens the distribution of sensitivities, so for 50% of sources the sensitivity is within 30% of its average. For the Galactic-disk population, the average and the distribution of the sensitivity for a moving detector turn out to be similar to the isotropic case.

  17. [An indirect ELISA using Legionella pneumophila recombinant MOMP protein and its application in serological diagnosis].

    PubMed

    Wang, Tao; Zhang, Caixia; Cao, Xiuqin; Yang, Zhiwei

    2013-12-01

    To express and purify the recombinant major outer membrane protein (MOMP) of Legionella pneumophila (Lp) as diagnostic antigen, and explore its practical value in the serological diagnosis of Lp infection. The recombinant plasmid pET-momp was transformed into the E.coli BL21 competent cells. The recombinant MOMP was induced to express, and then analyzed by SDS-PAGE electrophoresis, purified by affinity chromatography. We screened and obtained 58 positive blood serum and 32 negative blood serum using the DRG (Germany, IgG/IgM/IgA) Lp kit. The blood serum samples were detected for IgG, IgM, IgA antibody levels by indirect ELISA that we had established with the purified MOMP as the coating antigen, as well as by R&D (USA, IgG/IgM/IgA) Lp kit. Then using the receiver operating characteristic (ROC) curve, we compared these two methods in the sensitivity, specificity and consistency of the test results, for evaluating the application value of the indirect ELISA of recombinant MOMP. The approximately 45 000 recombinant MOMP was successfully expressed and purified. Compared with the indirect ELISA we established with the R&D Lp kit for detecting Lp antibody IgG, IgM and IgA in blood serum, the sensitivity of the indirect ELISA of recombinant MOMP to IgG was 90.9%, the specificity was 91.7%, the Kappa value was 0.784 (P < 0.05), and the area under the ROC curve was 0.913; the sensitivity to IgM was 91.4% and the specificity was 90.6%, the Kappa value was 0.809 (P < 0.05), and the area under the ROC curve was 0.910; the sensitivity to IgA was 92.1% and the specificity was 88.9%, the Kappa value was 0.793(P < 0.05), and the area under the ROC curve was 0.905. The recombinant MOMP was successfully induced to express and purified. The indirect ELISA we established with the recombinant MOMP protein as a diagnostic antigen showed good specificity, sensitivity and consistency, which laid a foundation for the development of serological diagnosis kit of Legionnaires' disease.

  18. SENS-5D trajectory and wind-sensitivity calculations for unguided rockets

    NASA Technical Reports Server (NTRS)

    Singh, R. P.; Huang, L. C. P.; Cook, R. A.

    1975-01-01

    A computational procedure is described which numerically integrates the equations of motion of an unguided rocket. Three translational and two angular (roll discarded) degrees of freedom are integrated through the final burnout; and then, through impact, only three translational motions are considered. Input to the routine is: initial time, altitude and velocity, vehicle characteristics, and other defined options. Input format has a wide range of flexibility for special calculations. Output is geared mainly to the wind-weighting procedure, and includes summary of trajectory at burnout, apogee and impact, summary of spent-stage trajectories, detailed position and vehicle data, unit-wind effects for head, tail and cross winds, coriolis deflections, range derivative, and the sensitivity curves (the so called F(Z) and DF(Z) curves). The numerical integration procedure is a fourth-order, modified Adams-Bashforth Predictor-Corrector method. This method is supplemented by a fourth-order Runge-Kutta method to start the integration at t=0 and whenever error criteria demand a change in step size.

  19. A neural model of motion processing and visual navigation by cortical area MST.

    PubMed

    Grossberg, S; Mingolla, E; Pack, C

    1999-12-01

    Cells in the dorsal medial superior temporal cortex (MSTd) process optic flow generated by self-motion during visually guided navigation. A neural model shows how interactions between well-known neural mechanisms (log polar cortical magnification, Gaussian motion-sensitive receptive fields, spatial pooling of motion-sensitive signals and subtractive extraretinal eye movement signals) lead to emergent properties that quantitatively simulate neurophysiological data about MSTd cell properties and psychophysical data about human navigation. Model cells match MSTd neuron responses to optic flow stimuli placed in different parts of the visual field, including position invariance, tuning curves, preferred spiral directions, direction reversals, average response curves and preferred locations for stimulus motion centers. The model shows how the preferred motion direction of the most active MSTd cells can explain human judgments of self-motion direction (heading), without using complex heading templates. The model explains when extraretinal eye movement signals are needed for accurate heading perception, and when retinal input is sufficient, and how heading judgments depend on scene layouts and rotation rates.

  20. The performance of blood pressure-to-height ratio as a screening measure for identifying children and adolescents with hypertension: a meta-analysis.

    PubMed

    Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai

    2016-02-01

    The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.

  1. Performance of blend sign in predicting hematoma expansion in intracerebral hemorrhage: A meta-analysis.

    PubMed

    Yu, Zhiyuan; Zheng, Jun; Guo, Rui; Ma, Lu; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao

    2017-12-01

    Hematoma expansion is independently associated with poor outcome in intracerebral hemorrhage (ICH). Blend sign is a simple predictor for hematoma expansion on non-contrast computed tomography. However, its accuracy for predicting hematoma expansion is inconsistent in previous studies. This meta-analysis is aimed to systematically assess the performance of blend sign in predicting hematoma expansion in ICH. A systematic literature search was conducted. Original studies about predictive accuracy of blend sign for hematoma expansion in ICH were included. Pooled sensitivity, specificity, positive and negative likelihood ratios were calculated. Summary receiver operating characteristics curve was constructed. Publication bias was assessed by Deeks' funnel plot asymmetry test. A total of 5 studies with 2248 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive and negative likelihood ratios of blend sign for predicting hematoma expansion were 0.28, 0.92, 3.4 and 0.78, respectively. The area under the curve (AUC) was 0.85. No significant publication bias was found. This meta-analysis demonstrates that blend sign is a useful predictor with high specificity for hematoma expansion in ICH. Further studies with larger sample size are still necessary to verify the accuracy of blend sign for predicting hematoma expansion. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department

    PubMed Central

    Balamuth, Fran; Alpern, Elizabeth R.; Grundmeier, Robert W.; Chilutti, Marianne; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-01-01

    Objectives To compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). Methods This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Results Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159, and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% CI = 72.1% to 73.4%) and specificity 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity 92.1% (95% CI = 91.7% to 92.4%), and specificity 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment vs. algorithmic alert were 40.3% vs. 2.5% and 99.88 % vs. 99.96%, respectively. Conclusions The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. PMID:26474032

  3. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department.

    PubMed

    Balamuth, Fran; Alpern, Elizabeth R; Grundmeier, Robert W; Chilutti, Marianne; Weiss, Scott L; Fitzgerald, Julie C; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-11-01

    The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively. The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. © 2015 by the Society for Academic Emergency Medicine.

  4. Quantitative Shear Wave Velocity Measurement on Acoustic Radiation Force Impulse Elastography for Differential Diagnosis between Benign and Malignant Thyroid Nodules: A Meta-analysis.

    PubMed

    Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao

    2015-12-01

    The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Charge and Geometry of Residues in the Loop 2 β Hairpin Differentially Affect Agonist and Ethanol Sensitivity in Glycine Receptors

    PubMed Central

    Perkins, Daya I.; Trudell, James R.; Asatryan, Liana; Alkana, Ronald L.

    2012-01-01

    Recent studies highlighted the importance of loop 2 of α1 glycine receptors (GlyRs) in the propagation of ligand-binding energy to the channel gate. Mutations that changed polarity at position 52 in the β hairpin of loop 2 significantly affected sensitivity to ethanol. The present study extends the investigation to charged residues. We found that substituting alanine with the negative glutamate at position 52 (A52E) significantly left-shifted the glycine concentration response curve and increased sensitivity to ethanol, whereas the negative aspartate substitution (A52D) significantly right-shifted the glycine EC50 but did not affect ethanol sensitivity. It is noteworthy that the uncharged glutamine at position 52 (A52Q) caused only a small right shift of the glycine EC50 while increasing ethanol sensitivity as much as A52E. In contrast, the shorter uncharged asparagine (A52N) caused the greatest right shift of glycine EC50 and reduced ethanol sensitivity to half of wild type. Collectively, these findings suggest that charge interactions determined by the specific geometry of the amino acid at position 52 (e.g., the 1-Å chain length difference between aspartate and glutamate) play differential roles in receptor sensitivity to agonist and ethanol. We interpret these results in terms of a new homology model of GlyR based on a prokaryotic ion channel and propose that these mutations form salt bridges to residues across the β hairpin (A52E-R59 and A52N-D57). We hypothesize that these electrostatic interactions distort loop 2, thereby changing agonist activation and ethanol modulation. This knowledge will help to define the key physical-chemical parameters that cause the actions of ethanol in GlyRs. PMID:22357974

  6. Experimental platform utilising melting curve technology for detection of mutations in Mycobacterium tuberculosis isolates.

    PubMed

    Broda, Agnieszka; Nikolayevskyy, Vlad; Casali, Nicki; Khan, Huma; Bowker, Richard; Blackwell, Gemma; Patel, Bhakti; Hume, James; Hussain, Waqar; Drobniewski, Francis

    2018-04-20

    Tuberculosis (TB) remains one of the most deadly infections with approximately a quarter of cases not being identified and/or treated mainly due to a lack of resources. Rapid detection of TB or drug-resistant TB enables timely adequate treatment and is a cornerstone of effective TB management. We evaluated the analytical performance of a single-tube assay for multidrug-resistant TB (MDR-TB) on an experimental platform utilising RT-PCR and melting curve analysis that could potentially be operated as a point-of-care (PoC) test in resource-constrained settings with a high burden of TB. Firstly, we developed and evaluated the prototype MDR-TB assay using specimens extracted from well-characterised TB isolates with a variety of distinct rifampicin and isoniazid resistance conferring mutations and nontuberculous Mycobacteria (NTM) strains. Secondly, we validated the experimental platform using 98 clinical sputum samples from pulmonary TB patients collected in high MDR-TB settings. The sensitivity of the platform for TB detection in clinical specimens was 75% for smear-negative and 92.6% for smear-positive sputum samples. The sensitivity of detection for rifampicin and isoniazid resistance was 88.9 and 96.0% and specificity was 87.5 and 100%, respectively. Observed limitations in sensitivity and specificity could be resolved by adjusting the sample preparation methodology and melting curve recognition algorithm. Overall technology could be considered a promising PoC methodology especially in resource-constrained settings based on its combined accuracy, convenience, simplicity, speed, and cost characteristics.

  7. Can CT imaging features of ground-glass opacity predict invasiveness? A meta-analysis.

    PubMed

    Dai, Jian; Yu, Guoyou; Yu, Jianqiang

    2018-04-01

    A meta-analysis was conducted to investigate the diagnostic performance of computed tomography (CT) imaging features of ground-glass opacity (GGO) to predict invasiveness. Two reviewers independently searched PubMed, Medline, Web of Science, Cochrane Embase and CNKI for relevant studies. CT imaging signs of bubble lucency, speculation, lobulated margin, and pleural indentation were used as diagnostic references to discriminate pre-invasive and invasive disease. The sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the area under the SROC curve (AUC) were calculated to evaluate diagnostic efficiency. Twelve studies were finally included. Diagnostic performance ranged from 0.41 to 0.52 for sensitivity and 0.56 to 0.63 for specificity. The diagnostic positive and negative likelihood ratios ranged from 1.03 to 2.13 and 0.52 to 1.05, respectively. The DORs of the GGO CT features for discriminating invasive disease ranged from 1.02 to 4.00. The area under the ROC curve was also low, with a range of 0.60 to 0.67 for discriminating pre-invasive and invasive disease. The diagnostic value of a single CT imaging sign of GGO, such as bubble lucency, speculation, lobulated margin, or pleural indentation is limited for discriminating pre-invasive and invasive disease because of low sensitivity, specificity, and AUC. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  8. The Shape of the Glucose Response Curve During an Oral Glucose Tolerance Test Heralds Biomarkers of Type 2 Diabetes Risk in Obese Youth

    PubMed Central

    Kim, Joon Young; Michaliszyn, Sara F.; Nasr, Alexis; Lee, SoJung; Tfayli, Hala; Hannon, Tamara; Hughan, Kara S.; Bacha, Fida; Arslanian, Silva

    2016-01-01

    OBJECTIVE The shape of the glucose response curve during an oral glucose tolerance test (OGTT), monophasic versus biphasic, identifies physiologically distinct groups of individuals with differences in insulin secretion and sensitivity. We aimed to verify the value of the OGTT-glucose response curve against more sensitive clamp-measured biomarkers of type 2 diabetes risk, and to examine incretin/pancreatic hormones and free fatty acid associations in these curve phenotypes in obese adolescents without diabetes. RESEARCH DESIGN AND METHODS A total of 277 obese adolescents without diabetes completed a 2-h OGTT and were categorized to either a monophasic or a biphasic group. Body composition, abdominal adipose tissue, OGTT-based metabolic parameters, and incretin/pancreatic hormone levels were examined. A subset of 106 participants had both hyperinsulinemic-euglycemic and hyperglycemic clamps to measure in vivo insulin sensitivity, insulin secretion, and β-cell function relative to insulin sensitivity. RESULTS Despite similar fasting and 2-h glucose and insulin concentrations, the monophasic group had significantly higher glucose, insulin, C-peptide, and free fatty acid OGTT areas under the curve compared with the biphasic group, with no differences in levels of glucagon, total glucagon-like peptide 1, glucose-dependent insulinotropic polypeptide, and pancreatic polypeptide. Furthermore, the monophasic group had significantly lower in vivo hepatic and peripheral insulin sensitivity, lack of compensatory first and second phase insulin secretion, and impaired β-cell function relative to insulin sensitivity. CONCLUSIONS In obese youth without diabetes, the risk imparted by the monophasic glucose curve compared with biphasic glucose curve, independent of fasting and 2-h glucose and insulin concentrations, is reflected in lower insulin sensitivity and poorer β-cell function, which are two major pathophysiological biomarkers of type 2 diabetes in youth. PMID:27293201

  9. Diagnosis of toxoplasmosis in pregnancy. Evaluation of latex-protein complexes by immnunoagglutination.

    PubMed

    Peretti, Leandro E; Gonzalez, Verónica D G; Marcipar, Iván S; Gugliotta, Luis M

    2017-07-01

    The aim of this work was to obtain a reagent based on latex particles for ruling out acute toxoplasmosis in pregnant women by immunoagglutination (IA). Latex-protein complexes (LPC) were previously synthesized coupling the recombinant protein of Toxoplasma gondii P22Ag and the homogenate of the parasite to latex particles with different size, chemical functionality and charge density. LPC were tested in IA assays against a panel of 72 pregnant women serum samples. Results were analysed through receiver operating characteristic curves, determining area under the curve (AUC), sensitivity, specificity positive and negative predictive values (PPV and NPV, respectively). It was observed that the antigenicity of proteins was not affected during sensitization by either physical adsorption or covalent coupling. The best results in the sense of maximizing discrimination of low avidity sera from chronic ones were observed for the IA test based on latex particles with carboxyl functionality and the recombinant P22Ag, obtaining an AUC of 0·94, a sensitivity of 100% and a NPV of 100%. In this way, the proposed test could be useful for the toxoplasmosis diagnosis in pregnant women, with the advantages of being cheap, rapid and easy to be implemented.

  10. Accidental falls in hospital inpatients: evaluation of sensitivity and specificity of two risk assessment tools.

    PubMed

    Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura

    2010-03-01

    This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.

  11. M-currents and other potassium currents in bullfrog sympathetic neurones

    PubMed Central

    Adams, P. R.; Brown, D. A.; Constanti, A.

    1982-01-01

    1. Bullfrog lumbar sympathetic neurones were voltage-clamped in vitro through twin micro-electrodes. Four different outward (K+) currents could be identified: (i) a large sustained voltage-sensitive delayed rectifier current (IK) activated at membrane potentials more positive than -25 mV; (ii) a calcium-dependent sustained outward current (IC) activated at similar positive potentials and peaking at +20 to +60 mV; (iii) a transient current (IA) activated at membrane potentials more positive than -60 mV after a hyperpolarizing pre-pulse, but which was rapidly and totally inactivated at all potentials within its activation range; and (iv) a new K+ current, the M-current (IM). 2. IM was detected as a non-inactivating current with a threshold at -60 mV. The underlying conductance GM showed a sigmoidal activation curve between -60 and -10 mV, with half-activation at -35 mV and a maximal value (ḠM) of 84±14 (S.E.M.) nS per neurone. The voltage sensitivity of GM could be expressed in terms of a simple Boltzmann distribution for a single multivalent gating particle. 3. IM activated and de-activated along an exponential time course with a time constant uniquely dependent upon voltage, maximizing at ≃ 150 ms at -35 mV at 22 °C. 4. Instantaneous current—voltage (I/V) curves were approximately linear in the presence of IM, suggesting that the M-channels do not show appreciable rectification. However, the time- and voltage-dependent opening of the M-channels induced considerable rectification in the steady-state I/V curves recorded under both voltage-clamp and current-clamp modes between -60 and -25 mV. Both time- and voltage-dependent rectification in the voltage responses to current injection over this range could be predicted from the kinetic properties of IM. 5. It is suggested that IM exerts a strong potential-clamping effect on the behaviour of these neurones at membrane potentials subthreshold to excitation. PMID:6294290

  12. Screening for depression in advanced disease: psychometric properties, sensitivity, and specificity of two items of the Palliative Care Outcome Scale (POS).

    PubMed

    Antunes, Bárbara; Murtagh, Fliss; Bausewein, Claudia; Harding, Richard; Higginson, Irene J

    2015-02-01

    Depression is common among patients with advanced disease but often difficult to detect. To assess the Palliative care Outcome Scale (POS) (10 items) against the Geriatric Depression Scale (GDS)-10 total score and the Hospital Anxiety and Depression Scale (HADS)-Depression subscale total score and determine if the POS has appropriate items to screen for depression among people with advanced disease. This was a secondary analysis performed on five studies. Four psychometric properties were assessed: data quality, scaling assumptions, acceptability, and internal consistency (reliability). Receiver operating characteristic (ROC) curves were used to determine the area under the curve. Sensitivity, specificity, positive and negative predictive values, false positive and negative rates, and positive and negative likelihood ratios were computed. The overall sample had 416 patients from Germany and England: 144 had cancer and 267 had nonmalignant conditions. Prevalence of depression across the sample was 17.5%. Floor and ceiling effects were rare. Cronbach's alpha coefficients for POS items 7 and 8 summed, GDS-10 and HADS-Depression items varied: 0.61 (heart failure) and 0.80 (cancer). Two items combined (Item 7-feeling depressed and Item 8-feeling good about yourself) consistently presented the highest area under the ROC curve, ranging from 0.76 (95% CI 0.60, 0.93) (Germany, lung cancer) to 0.97 (95% CI 0.91, 1.0) (heart failure), highest negative predictive value, and lowest false negative rate. For the overall sample, the cutoff 2/3 presented a negative predictive value of 89.4% (95% CI 84.7, 92.8) and false negative rate of 10.6 (95% CI 7.2, 15.3). POS items 7 and 8 summed are potentially useful to screen for depression in advanced disease populations. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  13. Direct Detection of Rifampin and Isoniazid Resistance in Sputum Samples from Tuberculosis Patients by High-Resolution Melt Curve Analysis

    PubMed Central

    Anthwal, Divya; Gupta, Rakesh Kumar; Bhalla, Manpreet; Bhatnagar, Shinjini

    2017-01-01

    ABSTRACT Drug-resistant tuberculosis (TB) is a major threat to TB control worldwide. Globally, only 40% of the 340,000 notified TB patients estimated to have multidrug-resistant-TB (MDR-TB) were detected in 2015. This study was carried out to evaluate the utility of high-resolution melt curve analysis (HRM) for the rapid and direct detection of MDR-TB in Mycobacterium tuberculosis in sputum samples. A reference plasmid library was first generated of the most frequently observed mutations in the resistance-determining regions of rpoB, katG, and an inhA promoter and used as positive controls in HRM. The assay was first validated in 25 MDR M. tuberculosis clinical isolates. The assay was evaluated on DNA isolated from 99 M. tuberculosis culture-positive sputum samples that included 84 smear-negative sputum samples, using DNA sequencing as gold standard. Mutants were discriminated from the wild type by comparing melting-curve patterns with those of control plasmids using HRM software. Rifampin (RIF) and isoniazid (INH) monoresistance were detected in 11 and 21 specimens, respectively, by HRM. Six samples were classified as MDR-TB by sequencing, one of which was missed by HRM. The HRM-RIF, INH-katG, and INH-inhA assays had 89% (95% confidence interval [CI], 52, 100%), 85% (95% CI, 62, 97%), and 100% (95% CI, 74, 100%) sensitivity, respectively, in smear-negative samples, while all assays had 100% sensitivity in smear-positive samples. All assays had 100% specificity. Concordance of 97% to 100% (κ value, 0.9 to 1) was noted between sequencing and HRM. Heteroresistance was observed in 5 of 99 samples by sequencing. In conclusion, the HRM assay was a cost-effective (Indian rupee [INR]400/US$6), rapid, and closed-tube method for the direct detection of MDR-TB in sputum, especially for direct smear-negative cases. PMID:28330890

  14. Ultrasonographic fetal head position to predict mode of delivery: a systematic review and bivariate meta-analysis.

    PubMed

    Verhoeven, C J M; Rückert, M E P F; Opmeer, B C; Pajkrt, E; Mol, B W J

    2012-07-01

    We performed a systematic review to determine whether sonographic assessment of occipital position of the fetal head can contribute to the prediction of the mode of delivery. We performed a systematic literature search of electronic databases from inception to May 2011. Two reviewers independently extracted data from the included studies. We used a bivariate model to estimate point estimates for sensitivity and specificity curves for the outcome Cesarean delivery. Eligible studies were cohort studies or cross-sectional studies that reported on both the position of the fetal head, as assessed by ultrasound, before or at the beginning of active labor as well as the outcome of labor in women at term. We included 11 primary articles reporting on 5053 women, of whom 898 had a Cesarean section. All studies indicated disappointing values for sensitivity and specificity in the prediction of Cesarean section. Summary point estimates of sensitivity and specificity were 0.39 (95% CI, 0.32-0.48) and 0.71 (95% CI, 0.67-0.74), respectively. Sonographic assessment of occipital position of the fetal head before delivery should not be used in the prediction of mode of delivery. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  15. Large lateral photovoltaic effect with ultrafast relaxation time in SnSe/Si junction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xianjie; Zhao, Xiaofeng; Hu, Chang

    In this paper, we report a large lateral photovoltaic effect (LPE) with ultrafast relaxation time in SnSe/p-Si junctions. The LPE shows a linear dependence on the position of the laser spot, and the position sensitivity is as high as 250 mV mm{sup −1}. The optical response time and the relaxation time of the LPE are about 100 ns and 2 μs, respectively. The current-voltage curve on the surface of the SnSe film indicates the formation of an inversion layer at the SnSe/p-Si interface. Our results clearly suggest that most of the excited-electrons diffuse laterally in the inversion layer at the SnSe/p-Si interface, whichmore » results in a large LPE with ultrafast relaxation time. The high positional sensitivity and ultrafast relaxation time of the LPE make the SnSe/p-Si junction a promising candidate for a wide range of optoelectronic applications.« less

  16. Demand for Colonoscopy in Colorectal Cancer Screening Using a Quantitative Fecal Immunochemical Test and Age/Sex-Specific Thresholds for Test Positivity.

    PubMed

    Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi

    2018-06-01

    Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.

  17. Predictive genetic testing for the identification of high-risk groups: a simulation study on the impact of predictive ability

    PubMed Central

    2011-01-01

    Background Genetic risk models could potentially be useful in identifying high-risk groups for the prevention of complex diseases. We investigated the performance of this risk stratification strategy by examining epidemiological parameters that impact the predictive ability of risk models. Methods We assessed sensitivity, specificity, and positive and negative predictive value for all possible risk thresholds that can define high-risk groups and investigated how these measures depend on the frequency of disease in the population, the frequency of the high-risk group, and the discriminative accuracy of the risk model, as assessed by the area under the receiver-operating characteristic curve (AUC). In a simulation study, we modeled genetic risk scores of 50 genes with equal odds ratios and genotype frequencies, and varied the odds ratios and the disease frequency across scenarios. We also performed a simulation of age-related macular degeneration risk prediction based on published odds ratios and frequencies for six genetic risk variants. Results We show that when the frequency of the high-risk group was lower than the disease frequency, positive predictive value increased with the AUC but sensitivity remained low. When the frequency of the high-risk group was higher than the disease frequency, sensitivity was high but positive predictive value remained low. When both frequencies were equal, both positive predictive value and sensitivity increased with increasing AUC, but higher AUC was needed to maximize both measures. Conclusions The performance of risk stratification is strongly determined by the frequency of the high-risk group relative to the frequency of disease in the population. The identification of high-risk groups with appreciable combinations of sensitivity and positive predictive value requires higher AUC. PMID:21797996

  18. Measurements of the sensitivity of radiochromic film using ion beams

    NASA Astrophysics Data System (ADS)

    Steidle, J. A.; Shortino, J. P.; Ellison, D. M.; Freeman, C. G.; Sangster, T. C.

    2013-10-01

    Radiochromic film (RCF) is used in several diagnostics as a dosimeter that chromatically responds to incident particles. This response depends on the fluence, energy, and species of the incident particles. A 1.7 MV tandem Pelletron accelerator is used to create a monoenergetic ion beam which is scattered off a thin gold target onto a strip of RCF. A surface barrier detector is positioned behind a small hole in the film to measure the ion fluence on the nearby film. Once the film develops, it is scanned to examine its optical density. A response curve is acquired by fitting a three parameter formula to optical density and dose. These calibration curves can be used to help determine incident doses in a variety of situations.

  19. Controlling Chaos Via Knowledge of Initial Condition for a Curved Structure

    NASA Technical Reports Server (NTRS)

    Maestrello, L.

    2000-01-01

    Nonlinear response of a flexible curved panel exhibiting bifurcation to fully developed chaos is demonstrated along with the sensitivity to small perturbation from the initial conditions. The response is determined from the measured time series at two fixed points. The panel is forced by an external nonharmonic multifrequency and monofrequency sound field. Using a low power time-continuous feedback control, carefully tuned at each initial condition, produces large long-term effects on the dynamics toward taming chaos. Without the knowledge of the initial conditions, control may be achieved by destructive interference. In this case, the control power is proportional to the loading power. Calculation of the correlation dimension and the estimation of positive Lyapunov exponents, in practice, are the proof of chaotic response.

  20. Validation of the Hospital Anxiety and Depression Scale in patients with epilepsy.

    PubMed

    Wiglusz, Mariusz S; Landowski, Jerzy; Michalak, Lidia; Cubała, Wiesław J

    2016-05-01

    Despite the fact that depressive disorders are the most common comorbidities among patients with epilepsy (PWEs), they often go unrecognized and untreated. The availability of validated screening instruments to detect depression in PWEs is limited. The aim of the present study was to validate the Hospital Anxiety and Depression Scale (HADS) in adult PWEs. A consecutive group of 118 outpatient PWEs was invited to participate in the study. Ninety-six patients met inclusion criteria, completed HADS, and were examined by a trained psychiatrist using Structured Clinical Interview (SCID-I) for DSM-IV-TR. Receiver operating characteristic (ROC) curves were used to determine the optimal threshold scores for the HADS depression subscale (HADS-D). Receiver operating characteristic analyses showed areas under the curve at approximately 84%. For diagnoses of MDD, the HADS-D demonstrated the best psychometric properties for a cutoff score ≥7 with sensitivity of 90.5%, specificity of 70.7%, positive predictive value of 46.3%, and negative predictive value of 96.4%. In the case of the group with 'any depressive disorder', the HADS-D optimum cutoff score was ≥6 with sensitivity of 82.5%, specificity of 73.2%, positive predictive value of 68.8%, and negative predictive value of 85.4%. The HADS-D proved to be a valid and reliable psychometric instrument in terms of screening for depressive disorders in PWEs. In the epilepsy setting, HADS-D maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing MDD with an optimum cutoff score ≥7. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. The utility of the Edmonton Symptom Assessment System in screening for anxiety and depression.

    PubMed

    Bagha, S M; Macedo, A; Jacks, L M; Lo, C; Zimmermann, C; Rodin, G; Li, M

    2013-01-01

    The Edmonton Symptom Assessment System (ESAS) is a common screening tool in cancer, although its validity for distress screening is unproven. Here, screening performance of the ESAS anxiety (ESAS-A) and depression (ESAS-D) items were validated against the anxiety [Generalised Anxiety Disorder-7 (GAD-7)] and depression [Patient Health Questionnaire-9 (PHQ-9)] subscales of the PHQ. A total of 1215 cancer patients completed the Distress Assessment and Response Tool (DART), a computerised distress screening instrument. Spearman's rank correlation coefficients and receiver operating characteristic curve analyses were used to evaluate the ability of ESAS-A and ESAS-D to identify moderate distress (GAD-7/PHQ-9 ≥ 10). Spearman's rank correlation coefficients comparing ESAS-A and ESAS-D with GAD-7 and PHQ-9 were 0.74 and 0.72 respectively. Areas under the receiver operating characteristic curves were 0.89 and 0.88 for anxiety and depression respectively. A cut-off of ≥3 on ESAS-A demonstrated a sensitivity of 0.91, specificity of 0.68, positive predictive value of 0.34 and negative predictive value of 0.97. A cut-off of ≥2 on the ESAS-D demonstrated a sensitivity of 0.86, specificity of 0.72, positive predictive value of 0.46 and negative predictive value of 0.95. High sensitivities of ESAS-A and ESAS-D at certain cut-offs suggest they have use in ruling-out distress. However, their low specificities indicate secondary screening is needed to rule-in anxiety or depression for case-finding. © 2012 Blackwell Publishing Ltd.

  2. Fatty liver index and hepatic steatosis index for prediction of non-alcoholic fatty liver disease in type 1 diabetes.

    PubMed

    Sviklāne, Laura; Olmane, Evija; Dzērve, Zane; Kupčs, Kārlis; Pīrāgs, Valdis; Sokolovska, Jeļizaveta

    2018-01-01

    Little is known about the diagnostic value of hepatic steatosis index (HSI) and fatty liver index (FLI), as well as their link to metabolic syndrome in type 1 diabetes mellitus. We have screened the effectiveness of FLI and HSI in an observational pilot study of 40 patients with type 1 diabetes. FLI and HSI were calculated for 201 patients with type 1 diabetes. Forty patients with FLI/HSI values corresponding to different risk of liver steatosis were invited for liver magnetic resonance study. In-phase/opposed-phase technique of magnetic resonance was used. Accuracy of indices was assessed from the area under the receiver operating characteristic curve. Twelve (30.0%) patients had liver steatosis. For FLI, sensitivity was 90%; specificity, 74%; positive likelihood ratio, 3.46; negative likelihood ratio, 0.14; positive predictive value, 0.64; and negative predictive value, 0.93. For HSI, sensitivity was 86%; specificity, 66%; positive likelihood ratio, 1.95; negative likelihood ratio, 0.21; positive predictive value, 0.50; and negative predictive value, 0.92. Area under the receiver operating characteristic curve for FLI was 0.86 (95% confidence interval [0.72; 0.99]); for HSI 0.75 [0.58; 0.91]. Liver fat correlated with liver enzymes, waist circumference, triglycerides, and C-reactive protein. FLI correlated with C-reactive protein, liver enzymes, and blood pressure. HSI correlated with waist circumference and C-reactive protein. FLI ≥ 60 and HSI ≥ 36 were significantly associated with metabolic syndrome and nephropathy. The tested indices, especially FLI, can serve as surrogate markers for liver fat content and metabolic syndrome in type 1 diabetes. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  3. Optimal cut-off of homeostasis model assessment of insulin resistance (HOMA-IR) for the diagnosis of metabolic syndrome: third national surveillance of risk factors of non-communicable diseases in Iran (SuRFNCD-2007).

    PubMed

    Esteghamati, Alireza; Ashraf, Haleh; Khalilzadeh, Omid; Zandieh, Ali; Nakhjavani, Manouchehr; Rashidi, Armin; Haghazali, Mehrdad; Asgari, Fereshteh

    2010-04-07

    We have recently determined the optimal cut-off of the homeostatic model assessment of insulin resistance for the diagnosis of insulin resistance (IR) and metabolic syndrome (MetS) in non-diabetic residents of Tehran, the capital of Iran. The aim of the present study is to establish the optimal cut-off at the national level in the Iranian population with and without diabetes. Data of the third National Surveillance of Risk Factors of Non-Communicable Diseases, available for 3,071 adult Iranian individuals aging 25-64 years were analyzed. MetS was defined according to the Adult Treatment Panel III (ATPIII) and International Diabetes Federation (IDF) criteria. HOMA-IR cut-offs from the 50th to the 95th percentile were calculated and sensitivity, specificity, and positive likelihood ratio for MetS diagnosis were determined. The receiver operating characteristic (ROC) curves of HOMA-IR for MetS diagnosis were depicted, and the optimal cut-offs were determined by two different methods: Youden index, and the shortest distance from the top left corner of the curve. The area under the curve (AUC) (95%CI) was 0.650 (0.631-0.670) for IDF-defined MetS and 0.683 (0.664-0.703) with the ATPIII definition. The optimal HOMA-IR cut-off for the diagnosis of IDF- and ATPIII-defined MetS in non-diabetic individuals was 1.775 (sensitivity: 57.3%, specificity: 65.3%, with ATPIII; sensitivity: 55.9%, specificity: 64.7%, with IDF). The optimal cut-offs in diabetic individuals were 3.875 (sensitivity: 49.7%, specificity: 69.6%) and 4.325 (sensitivity: 45.4%, specificity: 69.0%) for ATPIII- and IDF-defined MetS, respectively. We determined the optimal HOMA-IR cut-off points for the diagnosis of MetS in the Iranian population with and without diabetes.

  4. Optimizing the interpretation of CT for appendicitis: modeling health utilities for clinical practice.

    PubMed

    Blackmore, C Craig; Terasawa, Teruhiko

    2006-02-01

    Error in radiology can be reduced by standardizing the interpretation of imaging studies to the optimum sensitivity and specificity. In this report, the authors demonstrate how the optimal interpretation of appendiceal computed tomography (CT) can be determined and how it varies in different clinical scenarios. Utility analysis and receiver operating characteristic (ROC) curve modeling were used to determine the trade-off between false-positive and false-negative test results to determine the optimal operating point on the ROC curve for the interpretation of appendicitis CT. Modeling was based on a previous meta-analysis for the accuracy of CT and on literature estimates of the utilities of various health states. The posttest probability of appendicitis was derived using Bayes's theorem. At a low prevalence of disease (screening), appendicitis CT should be interpreted at high specificity (97.7%), even at the expense of lower sensitivity (75%). Conversely, at a high probability of disease, high sensitivity (97.4%) is preferred (specificity 77.8%). When the clinical diagnosis of appendicitis is equivocal, CT interpretation should emphasize both sensitivity and specificity (sensitivity 92.3%, specificity 91.5%). Radiologists can potentially decrease medical error and improve patient health by varying the interpretation of appendiceal CT on the basis of the clinical probability of appendicitis. This report is an example of how utility analysis can be used to guide radiologists in the interpretation of imaging studies and provide guidance on appropriate targets for the standardization of interpretation.

  5. Performance of the dipstick screening test as a predictor of negative urine culture.

    PubMed

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.

  6. Real-time nested multiplex PCR for the detection of herpes simplex virus types 1 and 2 and varicella zoster virus.

    PubMed

    O'Neill, Hugh J; Wyatt, Dorothy E; Coyle, Peter V; McCaughey, Conall; Mitchell, Frederick

    2003-12-01

    One hundred forty-nine specimens were tested in a LightCycler nested multiplex polymerase chain reaction (LCnmPCR) for Herpes simplex virus (HSV)1, HSV2, and VZV. Eighty-one were from genitourinary medicine (GUM) patients and the other 68 specimens were from other patients with skin lesions. The results were compared to a conventional multiplex nested PCR (nmPCR) using agarose gel electrophoresis. Twenty-five specimens were positive in both assays for HSV1 and 29 were positive for VZV. For HSV2 there were 27 positive in the LCnmPCR and 26 positive in the nmPCR assay. The melting temperatures (Tms) of each target were different with a mean of 84.75 degrees C for HSV1, 88.57 degrees C for HSV2, and 83.62 degrees C for VZV. The melting curves of positive specimens directly overlaid the melting curves of the positive controls in the assay. The LCnmPCR assay is a convenient alternative to conventional PCR using agarose gel electrophoresis. It improves specimen turnaround time by eliminating the need for gel electrophoresis, transillumination, and gel photography. It also shows increased sensitivity for HSV2 over our standard assay. This LCnmPCR reduces further the possibility of amplicon contamination with nested PCR protocols. Copyright 2003 Wiley-Liss, Inc.

  7. Evaluation of clinical methods for diagnosing bacterial vaginosis.

    PubMed

    Gutman, Robert E; Peipert, Jeffrey F; Weitzen, Sherry; Blume, Jeffrey

    2005-03-01

    To determine whether the current clinical criteria for diagnosing bacterial vaginosis can be simplified by using 2 clinical criteria rather than the standard 3 of 4 criteria (Amsel's criteria). This was a prospective observational study of 269 women undergoing a vaginal examination in the Women's Primary Care Center, Division of Research, or Colposcopy Clinic at Women & Infants Hospital. All 4 clinical criteria for diagnosing bacterial vaginosis were collected, and Gram stain was used as the gold standard. Sensitivity and specificity were calculated for each individual criterion, combinations of criteria, and a colorimetric pH and amine card. Receiver operating characteristic curve was generated to estimate the preferred pH and percentage of clue cells for diagnosing bacterial vaginosis. The prevalence of bacterial vaginosis in our study population was 38.7%. Vaginal pH was the most sensitive of all the criteria, at 89%, and a positive amine odor was the individual criteria with the highest specificity, at 93%. Similar specificity was seen with combinations of 2 criteria and Amsel's criteria. Receiver operating characteristic curve analysis yielded a preferred pH and percentage of clue cells of 5.0 and 20%, respectively. However, a pH of 4.5 or greater improves sensitivity with minimal loss of specificity. The clinical criteria for diagnosing bacterial vaginosis can be simplified to 2 clinical criteria without loss of sensitivity and specificity.

  8. Salivary Pepsin Lacks Sensitivity as a Diagnostic Tool to Evaluate Extraesophageal Reflux Disease.

    PubMed

    Dy, Fei; Amirault, Janine; Mitchell, Paul D; Rosen, Rachel

    2016-10-01

    To determine the sensitivity of salivary pepsin compared with multichannel intraluminal impedance with pH testing (pH-MII), endoscopy, and gastroesophageal reflux disease (GERD) questionnaires. We prospectively recruited 50 children from Boston Children's Hospital who were undergoing pH-MII to evaluate for GERD. The patients completed 24-hour pH-MII testing, completed symptom and quality of life questionnaires, and provided a saliva specimen that was analyzed using the PepTest lateral flow test. A subset of patients also underwent bronchoscopy and esophagogastroduodenoscopy. Receiver operating characteristic curve analyses were performed to determine the sensitivity of salivary pepsin compared with each reference standard. Twenty-one of the 50 patients (42%) were salivary pepsin-positive, with a median salivary pepsin concentration of 10 ng/mL (IQR, 10-55 ng/mL). There was no significant difference in the distributions of acid, nonacid, total reflux episodes, full column reflux, or any other reflux variable in patients who were pepsin-positive compared with those who were pepsin-negative (P > .50). There was no significant correlation between the number of reflux episodes and pepsin concentration (P > .10). There was no positive relationship between salivary pepsin positivity, any extraesophageal symptoms or quality of life scores, or inflammation on bronchoscopy or esophagogastroduodenoscopy (P > .30). Salivary pepsin measurement has a low sensitivity for predicting pathological gastroesophageal reflux in children. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Beyond the morphology of the glucose curve following an oral glucose tolerance test in obese youth.

    PubMed

    Nolfe, Giuseppe; Spreghini, Maria Rita; Sforza, Rita Wietrzycowska; Morino, Giuseppe; Manco, Melania

    2012-01-01

    To describe the morphology of glucose curve during the oral glucose tolerance test (OGTT) and any association with glucose tolerance, insulin action and secretion in obese youth. Cross-sectional. OGTT data of 553 patients were analysed. Subjects were divided in groups based on the morphology (i.e. monophasic, biphasic, triphasic and upward monotonous) of glucose curve. Insulin action was estimated by the homeostasis model assessment of insulin resistance, the insulin sensitivity, the muscle insulin sensitivity and the hepatic insulin resistance indexes (HIRI), and the oral glucose insulin sensitivity (OGIS). Insulin secretion was estimated by the insulinogenic index (IGI). Disposition index, including the insulin secretion-sensitivity index-2, and areas under glucose (AUC(G)) and insulin (AUC(I)) curves were computed. In patients with normal glucose tolerance (n=522), prevalent morphology of the glucose curve was monophasic (n=285, 54%). Monophasic morphology was associated with the highest concentration of 1 h plasma glucose (P<0.0001) and AUC(G) (P<0.0001); biphasic morphology with better insulin sensitivity as estimated by OGIS (P<0.03) and lower AUC(I) (P<0.0001); triphasic morphology with the highest values of HIRI (P<0.02) and IGI (P<0.007). By combining morphologies of glucose and insulin curves or time of the glucose peak, a deeper characterisation of different phenotypes of glucose metabolism emerged. Morphologies of the glucose curve seem reflecting different metabolic phenotypes of insulin action and secretion, particularly when combined with morphologies of insulin curve or time of glucose peak. Such findings may deserve validation in cohort study, in which glucose metabolism would be estimated by using gold standard techniques.

  10. Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airways: a new concept with possible clinical applications.

    PubMed

    Greenland, K B; Edwards, M J; Hutton, N J; Challis, V J; Irwin, M G; Sleigh, J W

    2010-11-01

    The sniffing position is often considered optimal for direct laryngoscopy. Another concept of airway configuration involving a laryngeal vestibule axis and two curves has also been suggested. We investigated whether this theory can be supported mathematically and if it supports the sniffing position as being optimal for direct laryngoscopy. Magnetic resonance imaging scans were performed in 42 normal adult volunteers. The airway passage was divided into two curves-primary (oro-pharyngeal curve) and secondary (pharyngo-glotto-tracheal curve). Airway configuration was evaluated in the neutral, extension, head lift, and sniffing positions. The airway passage, point of inflection (where the two curves meet), its tangent, and the line of sight were plotted on each scan. The point of inflection lay within the laryngeal vestibule in all positions. The head lift and sniffing positions caused the tangent to the point of inflection to approximate the horizontal plane. The sniffing, extension, and head lift positions caused a reduction in the area between the line of sight and the airway curve compared with the neutral position. A two-curve theory is proposed as a basis for explaining airway configuration. The changes in these curves with head and neck positioning support the sniffing position as optimal for direct laryngoscopy. Application of this new concept to other forms of laryngoscopy should be investigated.

  11. Tissue or blood: which is more suitable for detection of EGFR mutations in non-small cell lung cancer?

    PubMed

    Biaoxue, Rong; Shuanying, Yang

    2018-01-01

    Many studies have evaluated the accuracy of EGFR mutation status in blood against that in tumor tissues as the reference. We conducted this systematic review and meta-analysis to assess whether blood can be used as a substitute for tumor tissue in detecting EGFR mutations. Investigations that provided data on EGFR mutation status in blood were searched in the databases of Medline, Embase, Ovid Technologies and Web of Science. The detect efficiency of EGFR mutations in paired blood and tissues was compared using a random-effects model of meta-analysis. Pooled sensitivity and specificity and diagnostic accuracy were calculated by receiver operating characteristic curve. A total of 19 studies with 2,922 individuals were involved in this meta-analysis. The pooled results showed the positive detection rate of EGFR mutations in lung cancer tissues was remarkably higher than that of paired blood samples (odds ratio [OR] = 1.47, p<0.001). The pooled sensitivity and specificity of blood were 0.65 and 0.91, respectively, and the area under the receiver operating characteristic curve was 0.89. Although blood had a better specificity for detecting EGFR mutations, the absence of blood positivity should not necessarily be construed as confirmed negativity. Patients with negative results for blood should decidedly undergo further biopsies to ascertain EGFR mutations.

  12. Procalcitonin for the early prediction of renal parenchymal involvement in children with UTI: preliminary results.

    PubMed

    Kotoula, Aggeliki; Gardikis, Stefanos; Tsalkidis, Aggelos; Mantadakis, Elpis; Zissimopoulos, Athanassios; Kambouri, Katerina; Deftereos, Savvas; Tripsianis, Gregorios; Manolas, Konstantinos; Chatzimichael, Athanassios; Vaos, George

    2009-01-01

    In order to establish the most reliable marker for distinguishing urinary tract infections (UTI) with and without renal parenchymal involvement (RPI), we recorded the clinical features and admission leukocyte count, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and serum procalcitonin (PCT) in 57 children (including 43 girls) aged 2-108 months admitted with a first episode of UTI. RPI was evaluated by Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy within 7 days of admission. To establish cut-off points for ESR, CRP, and PCT, we used receiver operating characteristics curves and compared the area under the curve for ESR, CRP, and PCT. Twenty-seven children were diagnosed as having RPI based on positive renal scintigraphy. A body temperature of >38 degrees C, a history of diarrhea, and poor oral intake were more common in patients with RPI. ESR, CRP, and PCT, but not leukocyte count, were significantly higher in patients with RPI (P < 0.001). PCT was more sensitive and specific for the diagnosis of upper versus lower UTI than ESR and CRP. Using a cut-off value of 0.85 ng/ml, PCT had the best performance, with sensitivity, specificity, and positive and negative predictive values of 89%, 97%, 96%, and 91% respectively. Serum PCT is a better marker than ESR, CRP, and leukocyte count for the early prediction of RPI in children with a first episode of UTI.

  13. Is the MARS questionnaire a reliable measure of medication adherence in childhood asthma?

    PubMed

    Garcia-Marcos, Patricia W; Brand, Paul L P; Kaptein, Adrian A; Klok, Ted

    2016-12-01

    To assess the reliability of the Medication Adherence Report Scale (MARS-5) for assessing adherence in clinical practice and research. Prospective cohort study following electronically measured inhaled corticosteroids (ICS) adherence for 1 year in 2-13-year-old children with persistent asthma. The relationship between electronically measured adherence and MARS-5 scores (ranging from 5 to 25) was assessed by Spearman's rank correlation coefficient. A ROC (receiver operating characteristic) curve was performed testing MARS-5 against electronically measured adherence. Sensitivity, specificity, positive and negative likelihood ratios of the closest MARS-5 cut-off values to the top left-hand corner of the ROC curve were calculated. High MARS scores were obtained (median 24, interquartile range 22-24). Despite a statistically significant correlation between MARS-5 and electronically assessed adherence (Spearman's rho = 0.47; p < 0.0001), there was considerable variation of adherence rates at every MARS-5 score. The area under the ROC curve was 0.7188. A MARS-5 score ≥23 had the best predictive ability for electronically assessed adherence, but positive and negative likelihood ratios were too small to be useful (1.65 and 0.27, respectively). Self-report using MARS-5 is too inaccurate to be a useful measure of adherence in children with asthma, both in clinical practice and in research.

  14. Accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue.

    PubMed

    Zhang, Jing; Fan, Yimeng; He, Min; Ma, Xuelei; Song, Yanlin; Liu, Ming; Xu, Jianguo

    2017-05-30

    Raman spectroscopy could be applied to distinguish tumor from normal tissues. This meta-analysis was conducted to assess the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. PubMed and Embase were searched to identify suitable studies prior to Jan 1st, 2016. We estimated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), diagnostic odds ratio (DOR), and constructed summary receiver operating characteristics (SROC) curves to identity the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. A total of six studies with 1951 spectra were included. For glioma, the pooled sensitivity and specificity of Raman spectroscopy were 0.96 (95% CI 0.94-0.97) and 0.99 (95% CI 0.98-0.99), respectively. The area under the curve (AUC) was 0.9831. For meningioma, the pooled sensitivity and specificity were 0.98 (95% CI 0.94-1.00) and 1.00 (95% CI 0.98-1.00), respectively. The AUC was 0.9955. This meta-analysis suggested that Raman spectroscopy could be an effective and accurate tool for differentiating glioma and meningioma from normal brain tissue, which would help us both avoid removal of normal tissue and minimize the volume of residual tumor.

  15. Variable distributional characteristics of substrate utilization patterns in activated sludge plants in Kuwait.

    PubMed

    Al-Mutairi, N Z

    2009-02-01

    The objective of this study was to determine the magnitude of microbial functional potential and community structure between three different WWTPs using the Lorenz curve method and to find the effect of seasonal variation on patterns of substrate utilization. Lorenz curve method was sensitive enough to detect short-term changes in microbial functional diversity between Riqqa, Umm Al-Haiman and Al-Jahra activated sludge systems and showed seasonal variations of the utilized carbon sources. Gini coefficient ranged from 0.21 to 0.8. Lorenz curves seemed particularly suitable to present microbial heterogeneity in term of inequality and to highlight the relative contribution of low-and high functional diversity for the three different types of mixed liquors. Correlation analysis of the experimental data show that the complement of the Gini coefficient was strongly and positively correlated with the Shannon index (r(xy)=0.89), evenness (r(xy)=0.91), and AWCD (r(xy)=0.95) at the 95% level of significance (alpha=0.05).

  16. Prediction of Advisability of Returning Home Using the Home Care Score

    PubMed Central

    Matsugi, Akiyoshi; Tani, Keisuke; Tamaru, Yoshiki; Yoshioka, Nami; Yamashita, Akira; Mori, Nobuhiko; Oku, Kosuke; Ikeda, Masashi; Nagano, Kiyoshi

    2015-01-01

    Purpose. The aim of this study was to assess whether the home care score (HCS), which was developed by the Ministry of Health and Welfare in Japan in 1992, is useful for the prediction of advisability of home care. Methods. Subjects living at home and in assisted-living facilities were analyzed. Binominal logistic regression analyses, using age, sex, the functional independence measure score, and the HCS, along with receiver operating characteristic curve analyses, were conducted. Findings/Conclusions. Only HCS was selected for the regression equation. Receiver operating characteristic curve analysis revealed that the area under the curve (0.9), sensitivity (0.82), specificity (0.83), and positive predictive value (0.84) for HCS were higher than those for the functional independence measure, indicating that the HCS is a powerful predictor for advisability of home care. Clinical Relevance. Comprehensive measurements of the condition of provided care and the activities of daily living of the subjects, which are included in the HCS, are required for the prediction of advisability of home care. PMID:26491568

  17. An evaluation of the diagnostic accuracy of the 1991 American College of Chest Physicians/Society of Critical Care Medicine and the 2001 Society of Critical Care Medicine/European Society of Intensive Care Medicine/American College of Chest Physicians/American Thoracic Society/Surgical Infection Society sepsis definition.

    PubMed

    Zhao, Huifang; Heard, Stephen O; Mullen, Marie T; Crawford, Sybil; Goldberg, Robert J; Frendl, Gyorgy; Lilly, Craig M

    2012-06-01

    Limited research has been conducted to compare the test characteristics of the 1991 and 2001 sepsis consensus definitions. This study assessed the accuracy of the two sepsis consensus definitions among adult critically ill patients compared to sepsis case adjudication by three senior clinicians. Observational study of patients admitted to intensive care units. Seven intensive care units of an academic medical center. A random sample of 960 patients from all adult intensive care unit patients between October 2007 and December 2008. None. Sensitivity, specificity, and the area under the receiver operating characteristic curve for the two consensus definitions were calculated by comparing the number of patients who met or did not meet consensus definitions vs. the number of patients who were or were not diagnosed with sepsis by adjudication. The 1991 sepsis definition had a high sensitivity of 94.6%, but a low specificity of 61.0%. The 2001 sepsis definition had a slightly increased sensitivity but a decreased specificity, which were 96.9% and 58.3%, respectively. The areas under the receiver operating characteristic curve for the two definitions were not statistically different (0.778 and 0.776, respectively). The sensitivities and areas under the receiver operating characteristic curve of both definitions were lower at the 24-hr time window level than those of the intensive care unit stay level, though their specificities increased slightly. Fever, high white blood cell count or immature forms, low Glasgow coma score, edema, positive fluid balance, high cardiac index, low PaO2/FIO2 ratio, and high levels of creatinine and lactate were significantly associated with sepsis by both definitions and adjudication. Both the 1991 and the 2001 sepsis definition have a high sensitivity but low specificity; the 2001 definition has a slightly increased sensitivity but a decreased specificity compared to the 1991 definition. The diagnostic performances of both definitions were suboptimal. A parsimonious set of significant predictors for sepsis diagnosis is likely to improve current sepsis case definitions.

  18. A positive Babinski reflex predicts delayed neuropsychiatric sequelae in Chinese patients with carbon monoxide poisoning.

    PubMed

    Zou, Jian-Fang; Guo, Qiming; Shao, Hua; Li, Bin; Du, Yuxiu; Liu, Maofeng; Liu, Fengling; Dai, Lixin; Chung, Min-Hsien; Lin, Hung-Jung; Guo, How-Ran; Yang, Tzu-Meng; Huang, Chien-Cheng; Hsu, Chien-Chin

    2014-01-01

    As the human population increased in China, the carbon monoxide is a serious environmental toxin in public health. However, predicting the delayed neuropsychiatric sequelae (DNS) of carbon monoxide poisoning (COP) has not been well studied. We investigated the independent predictors of DNS in patients with COP. This study was conducted at four hospitals in China. Data were retrospectively collected from 258 patients with COP between November 1990 and October 2011. DNS was the primary endpoint. A positive Babinski reflex was the independent predictor for DNS: sensitivity = 53.8% (95% confidence interval [CI]: 26.1-79.6), specificity = 88.6% (95% CI: 83.7-92.1), positive predictive value (PPV) = 20.0% (95% CI: 9.1-37.5), and negative predictive value (NPV) = 97.3% (95% CI: 94.0-98.9). The area under the receiver operating characteristic curve = 0.712 (95% CI: 0.544-0.880). A positive Babinski reflex was very memorable, immediately available, and applicable in clinical practice. Even when the sensitivity and PPV of a positive Babinski reflex were unsatisfactory, it had a good specificity and NPV for excluding the risk of DNS. In patients without a positive Babinski reflex, the risk for DNS was only 2.7%. This finding may help physicians make decisions about dispositions for patients with COP.

  19. Generalization and refinement of an automatic landing system capable of curved trajectories

    NASA Technical Reports Server (NTRS)

    Sherman, W. L.

    1976-01-01

    Refinements in the lateral and longitudinal guidance for an automatic landing system capable of curved trajectories were studied. Wing flaps or drag flaps (speed brakes) were found to provide faster and more precise speed control than autothrottles. In the case of the lateral control it is shown that the use of the integral of the roll error in the roll command over the first 30 to 40 seconds of flight reduces the sensitivity of the lateral guidance to the gain on the azimuth guidance angle error in the roll command. Also, changes to the guidance algorithm are given that permit pi-radian approaches and constrain the airplane to fly in a specified plane defined by the position of the airplane at the start of letdown and the flare point.

  20. Comparison of the clinical and microbiological characteristics of Campylobacter and Helicobacter bacteremia: the importance of time to blood culture positivity using the BACTEC blood culture systems.

    PubMed

    Yamamoto, Kei; Hayakawa, Kayoko; Nagashima, Maki; Shimada, Kayo; Kutsuna, Satoshi; Takeshita, Nozomi; Kato, Yasuyuki; Kanagawa, Shuzo; Yamada, Koji; Mezaki, Kazuhisa; Kirikae, Teruo; Ohmagari, Norio

    2017-11-28

    Campylobacter spp. and Helicobacter spp. are rare but important causes of bacteremia in humans. Distinguishing these bacteria is complicated because of their similar phenotypic profiles. We conducted clinical and microbiological investigations of Campylobacter spp. or Helicobacter spp. bacteremia. Patients diagnosed with bacteremia from 2008 to 2014 were included. The clinical and microbiological characteristics of Campylobacter spp. and Helicobacter spp. bacteremia were compared. The BACTEC system was used in blood cultures. A receiver operating characteristic curve was plotted based on the time to blood culture positivity. Sixteen cases of Helicobacter spp. bacteremia (patient age: 61 ± 18 years) and 14 cases of Campylobacter spp. bacteremia (patient age: 49 ± 21 years) were identified. Median time to blood culture positivity was longer for the Helicobacter spp. cases than the Campylobacter spp. cases (91.4 h vs 55.3 h, p < 0.01). A time to blood culture positivity > 75 h predicted Helicobacter spp. bacteremia with a sensitivity of 0.88 and a specificity of 0.93 (area under the receiver operating characteristic curve of 0.90). In conclusion, a time to blood culture positivity was useful in distinguishing Helicobacter spp. bacteremia from Campylobacter spp. bacteremia.

  1. The effect of chevron alignment signs on driver performance on horizontal curves with different roadway geometries.

    PubMed

    Zhao, Xiaohua; Wu, Yiping; Rong, Jian; Ma, Jianming

    2015-02-01

    To develop a practicable and clear guideline for implementing Chevrons on China's highways, it is necessary to understand the effect of Chevrons on driving performance in different roadway geometries. Using a driving simulator, this study tests the effect of China's Chevrons on vehicle speed and lane position on two-lane rural highway horizontal curves with different roadway geometries. The results showed a significant effect of Chevrons on speed reduction, and this function was not significantly affected by curve radius but was statistically affected by curve direction. The speed reduction caused by Chevrons was also significant at the approach of curve, middle of curve and point of tangent. The 85th percentile speed was also markedly lower when Chevrons were present. We also found a significant effect of Chevrons in encouraging participants to drive the vehicle with a more proper lane position at the first half of curves; and this function was slightly affected by curve radius. Meanwhile, the effect of Chevrons on keeping drivers staying in a more stable lane position was also statistically significant at the second half of curves. In sharp curves, the function of Chevrons to make drivers keep a stable lane position was lost. Besides, the impact of curve direction on the function of Chevrons on lane position was always present, and drivers would drive slightly away from Chevrons. Regardless of the curve radius, China's Chevrons at horizontal curves provide an advance warning, speed control and lane position guide for traffic on the nearside of Chevrons. Besides, combing with the function of Chevrons on preventing excessive speed and the benefit to make drivers keep a more proper lane position, China's Chevrons appear to be of great benefit to reduce crashes (e.g., run-off-road) in curves. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Diagnostic performance of instantaneous wave-free ratio for the evaluation of coronary stenosis severity confirmed by fractional flow reserve: A PRISMA-compliant meta-analysis of randomized studies.

    PubMed

    Man, Wanrong; Hu, Jianqiang; Zhao, Zhijing; Zhang, Mingming; Wang, Tingting; Lin, Jie; Duan, Yu; Wang, Ling; Wang, Haichang; Sun, Dongdong; Li, Yan

    2016-09-01

    The instantaneous wave-free ratio (iFR) is a new vasodilator-free index of coronary stenosis severity. The aim of this meta-analysis is to assess the diagnostic performance of iFR for the evaluation of coronary stenosis severity with fractional flow reserve as standard reference. We searched PubMed, EMBASE, CENTRAL, ProQuest, Web of Science, and International Clinical Trials Registry Platform (ICTRP) for publications concerning the diagnostic value of iFR. We used a random-effects covariate to synthesize the available data of sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR). Overall test performance was summarized by the summary receiver operating characteristic curve (sROC) and the area under the curve (AUC). Eight studies with 1611 subjects were included in the meta-analysis. The pooled sensitivity, specificity, LR+, LR-, and DOR for iFR were respectively 73.3% (70.1-76.2%), 86.4% (84.3-88.3%), 5.71 (4.43-7.37), 0.29 (0.22-0.38), and 20.54 (16.11-26.20). The area under the summary receiver operating characteristic curves for iFR was 0.8786. No publication bias was identified. The available evidence suggests that iFR may be a new, simple, and promising technology for coronary stenosis physiological assessment.

  3. X-ray and optical observations of 2 new cataclysmic variables

    NASA Technical Reports Server (NTRS)

    Singh, K. P.; Szkody, P.; Barrett, P.; Schlegel, E.; White, N. E.; Silber, A.; Fierce, E.; Hoard, D.; Hakala, P. J.; Piirola, V.; hide

    1996-01-01

    The light curves and spectra of two ultra soft X-ray sources are presented. The sources, WGAJ 1047.1+6335 and WGAJ 1802.1+1804 were discovered during a search using the Rosat position sensitive proportional counter (PSPC). The X-ray spectra of both objects show an unusually strong black body component with respect to the harder bremsstrahlung component. Based on the optical observations and on the analysis of the X-ray data, the two objects are identified with new AM Her type cataclysmic variables.

  4. Beam/seam alignment control for electron beam welding

    DOEpatents

    Burkhardt, Jr., James H.; Henry, J. James; Davenport, Clyde M.

    1980-01-01

    This invention relates to a dynamic beam/seam alignment control system for electron beam welds utilizing video apparatus. The system includes automatic control of workpiece illumination, near infrared illumination of the workpiece to limit the range of illumination and camera sensitivity adjustment, curve fitting of seam position data to obtain an accurate measure of beam/seam alignment, and automatic beam detection and calculation of the threshold beam level from the peak beam level of the preceding video line to locate the beam or seam edges.

  5. Predictive Value of Matrix Metalloproteinases and Their Inhibitors for Mortality in Septic Patients: A Cohort Study.

    PubMed

    Serrano-Gomez, Sergio; Burgos-Angulo, Gabriel; Niño-Vargas, Daniela Camila; Niño, María Eugenia; Cárdenas, María Eugenia; Chacón-Valenzuela, Estephania; McCosham, Diana Margarita; Peinado-Acevedo, Juan Sebastián; Lopez, M Marcos; Cunha, Fernando; Pazin-Filho, Antonio; Ilarraza, Ramses; Schulz, Richard; Torres-Dueñas, Diego

    2017-01-01

    Over 170 biomarkers are being investigated regarding their prognostic and diagnostic accuracy in sepsis in order to find new tools to reduce morbidity and mortality. Matrix metalloproteinases (MMPs) and their inhibitors have been recently studied as promising new prognostic biomarkers in patients with sepsis. This study is aimed at determining the utility of several cutoff points of these biomarkers to predict mortality in patients with sepsis. A multicenter, prospective, analytic cohort study was performed in the metropolitan area of Bucaramanga, Colombia. A total of 289 patients with sepsis and septic shock were included. MMP-9, MMP-2, tissue inhibitor of metalloproteinase 1 (TIMP-1), TIMP-2, TIMP-1/MMP-9 ratio, and TIMP-2/MMP-2 ratio were determined in blood samples. Value ranges were correlated with mortality to estimate sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiving operating characteristic curve. Sensitivity ranged from 33.3% (MMP-9/TIMP-1 ratio) to 60.6% (TIMP-1) and specificity varied from 38.8% (MMP-2/TIMP-2 ratio) to 58.5% (TIMP-1). As for predictive values, positive predictive value range was from 17.5% (MMP-9/TIMP-1 ratio) to 70.4% (MMP-2/TIMP-2 ratio), whereas negative predictive values were between 23.2% (MMP-2/TIMP-2 ratio) and 80.9% (TIMP-1). Finally, area under the curve scores ranged from 0.31 (MMP-9/TIMP-1 ratio) to 0.623 (TIMP-1). Although TIMP-1 showed higher sensitivity, specificity, and negative predictive value, with a representative population sample, we conclude that none of the evaluated biomarkers had significant predictive value for mortality.

  6. Improved instrumental magnitude prediction expected from version 2 of the NASA SKY2000 master star catalog

    NASA Technical Reports Server (NTRS)

    Sande, C. B.; Brasoveanu, D.; Miller, A. C.; Home, A. T.; Tracewell, D. A.; Warren, W. H., Jr.

    1998-01-01

    The SKY2000 Master Star Catalog (MC), Version 2 and its predecessors have been designed to provide the basic astronomical input data needed for satellite acquisition and attitude determination on NASA spacecraft. Stellar positions and proper motions are the primary MC data required for operations support followed closely by the stellar brightness observed in various standard astronomical passbands. The instrumental red-magnitude prediction subsystem (REDMAG) in the MMSCAT software package computes the expected instrumental color index (CI) [sensor color correction] from an observed astronomical stellar magnitude in the MC and the characteristics of the stellar spectrum, astronomical passband, and sensor sensitivity curve. The computation is more error prone the greater the mismatch of the sensor sensitivity curve characteristics and those of the observed astronomical passbands. This paper presents the preliminary performance analysis of a typical red-sensitive CCDST during acquisition of sensor data from the two Ball CT-601 ST's onboard the Rossi X-Ray Timing Explorer (RXTE). A comparison is made of relative star positions measured in the ST FOV coordinate system with the expected results computed from the recently released Tycho Catalogue. The comparison is repeated for a group of observed stars with nearby, bright neighbors in order to determine the tracker behavior in the presence of an interfering, near neighbor (NN). The results of this analysis will be used to help define a new photoelectric photometric instrumental sensor magnitude system (S) that is based on several thousand bright star magnitudes observed with the PXTE ST's. This new system will be implemented in Version 2 of the SKY2000 MC to provide improved predicted magnitudes in the mission run catalogs.

  7. Developing the Thai Siriraj Psoriatic Arthritis Screening Tool and validating the Thai Psoriasis Epidemiology Screening Tool and the Early Arthritis for Psoriatic Patients questionnaire.

    PubMed

    Chiowchanwisawakit, Praveena; Wattanamongkolsil, Luksame; Srinonprasert, Varalak; Petcharat, Chonachan; Siriwanarangsun, Palanan; Katchamart, Wanruchada

    2016-10-01

    To validate the Thai language version of the Psoriasis Epidemiology Screening Tool (PEST) and the Early Arthritis for Psoriatic Patients Questionnaire (EARP), as well as also to develop a new tool for screening psoriatic arthritis (PsA) among psoriasis (Ps) patients. This was a cross-sectional study. Ps patients visiting the psoriasis clinic at Siriraj Hospital were recruited. They completed the EARP and PEST. Full musculoskeletal history, examination, and radiography were evaluated. PsA was diagnosed by a rheumatologist's evaluation and fulfillment of the classification criteria for psoriatic arthritis. Receiver operator characteristic (ROC) curves, sensitivity, and specificity were used to evaluate the performances of the tools. The Siriraj Psoriatic Arthritis Screening Tool (SiPAT) contained questions most relevant to peripheral arthritis, axial inflammation, and enthesitis, selected from multivariate analysis. Of a total of 159 patients, the prevalence of PsA was 78.6 %. The ROC curve analyses of Thai EARP, PEST, and SiPAT were 0.90 (95 % CI 0.84, 0.96), 0.85 (0.78, 0.92), and 0.89 (0.83, 0.95), respectively. The sensitivities of SiPAT, Thai EARP, and PEST were 91.0, 83.0, and 72.0 %, respectively, while the specificities were 69.0, 79.3, and 89.7 %, respectively. All screening questionnaires showed good diagnostic performances. SiPAT could be considered as a screening tool with its desirable properties: higher sensitivity and taking less time. Thai PEST and EARP could possibly be sequentially administered for people with a positive test from SiPAT to reduce the number of false positives.

  8. Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma.

    PubMed

    Vidotti, Vanessa G; Costa, Vital P; Silva, Fabrício R; Resende, Graziela M; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S

    2012-06-15

    Purpose. To investigate the sensitivity and specificity of machine learning classifiers (MLC) and spectral domain optical coherence tomography (SD-OCT) for the diagnosis of glaucoma. Methods. Sixty-two patients with early to moderate glaucomatous visual field damage and 48 healthy individuals were included. All subjects underwent a complete ophthalmologic examination, achromatic standard automated perimetry, and RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, California, USA). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters. Subsequently, the following MLCs were tested: Classification Tree (CTREE), Random Forest (RAN), Bagging (BAG), AdaBoost M1 (ADA), Ensemble Selection (ENS), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Naive-Bayes (NB), and Support Vector Machine (SVM). Areas under the ROC curves (aROCs) obtained for each parameter and each MLC were compared. Results. The mean age was 57.0±9.2 years for healthy individuals and 59.9±9.0 years for glaucoma patients (p=0.103). Mean deviation values were -4.1±2.4 dB for glaucoma patients and -1.5±1.6 dB for healthy individuals (p<0.001). The SD-OCT parameters with the greater aROCs were inferior quadrant (0.813), average thickness (0.807), 7 o'clock position (0.765), and 6 o'clock position (0.754). The aROCs from classifiers varied from 0.785 (ADA) to 0.818 (BAG). The aROC obtained with BAG was not significantly different from the aROC obtained with the best single SD-OCT parameter (p=0.93). Conclusions. The SD-OCT showed good diagnostic accuracy in a group of patients with early glaucoma. In this series, MLCs did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.

  9. The diagnostic performance of perfusion MRI for differentiating glioma recurrence from pseudoprogression: A meta-analysis.

    PubMed

    Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo

    2017-03-01

    The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.

  10. Is the 15∆ Base in Prism Test Reliable for Detection of Amblyopia in Anisometropic Patients?

    PubMed

    Burggraaf, F; Verkaik-Rijneveld, M C; Wubbels, R J; de Jongh, E

    2017-09-01

    The 15∆ base in prism test (15∆BIPT) introduced by Gobin is often used in The Netherlands to detect fixation preference, especially in young and preverbal children in whom a reliable measurement of the visual acuity (VA) is difficult. It is assumed that the fixation preference detected by the 15∆BIPT can be used to predict the presence of amblyopia. The aim of this retrospective case note review was to investigate the accuracy of the 15∆BIPT in detection of amblyopia in anisometropic patients. Four hundred and twelve files of anisometropic patients visiting the orthoptic department of The Rotterdam Eye Hospital were analyzed. Amblyopia was defined as an intraocular difference in VA of 2 or more Snellen lines. The sensitivity, specificity, and positive and negative predictive values of the 15∆BIPT were calculated and the receiver operating characteristic (ROC) curve was plotted. One hundred and fifty-two patients ranging from 3.3-13.1 years of age (median 5.4 years) met the inclusion criteria. One hundred and two patients were diagnosed with amblyopia. Best-corrected median VA of the best eye was 1.0 (range 0.5-1.2) and the worst eye 0.70 (range 0.05-1.2). Sensitivity of the 15∆BIPT (based on detecting amblyopia) was 34.3%. Specificity was 88.0%. The positive predictive value was 85.4% versus a negative predictive value of 39.6%. The area under the ROC curve (AUC) was 0.65 (95% CI 0.56-0.74). The low sensitivity, large number of false negatives and the AUC show that the 15∆BIPT can be considered a poor test for detecting amblyopia in anisometropic patients.

  11. Clinical Utility of Urinary Cytology to Detect BK Viral Nephropathy.

    PubMed

    Nankivell, Brian J; Renthawa, Jasveen; Jeoffreys, Neisha; Kable, Kathy; O'Connell, Philip J; Chapman, Jeremy R; Wong, Germaine; Sharma, Raghwa N

    2015-08-01

    Reactivation of BK polyoma virus can result in destructive viral allograft nephropathy (BKVAN) with limited treatment options. Screening programs using surrogate markers of viral replication are important preventive strategies, guiding immunosuppression reduction. We prospectively evaluated the diagnostic test performance of urinary decoy cells and urinary SV40T immunochemistry of exfoliated cells, to screen for BKVAN, (defined by reference histology with SV40 immunohistochemistry, n = 704 samples), compared with quantitative viremia, from 211 kidney and 141 kidney-pancreas transplant recipients. The disease prevalence of BKVAN was 2.6%. Decoy cells occurred in 95 of 704 (13.5%) samples, with a sensitivity of 66.7%, specificity of 88.6%, positive predictive value (PPV) of 11.7%, and negative predictive value of 98.5% to predict histologically proven BKVAN. Quantification of decoy cells improved the PPV to 32.1% (10 ≥ cells threshold). Immunohistochemical staining of urinary exfoliated cells for SV40T improved sensitivity to 85.7%, detecting atypical or degenerate infected cells (specificity of 92.3% and PPV of 33.3%), but was hampered by technical failures. Viremia occurred in 90 of 704 (12.8%) with sensitivity of 96.3%, specificity of 90.3%, PPV of 31.5%, and negative predictive value of 99.8%. The receiver-operator curve performance of quantitative viremia surpassed decoy cells (area under the curve of 0.95 and 0.79, respectively, P = 0.0018 for differences). Combining decoy cell and BK viremia in a diagnostic matrix improved prediction of BKVAN and diagnostic risk stratification, especially for high-level positive results. Although quantified decoy cells are acceptable surrogate markers of BK viral replication with unexceptional test performances, quantitative viremia displayed superior test characteristics and is suggested as the screening test of choice.

  12. Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.

    PubMed

    Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching

    2016-02-01

    To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.

  13. CSF lactate alone is not a reliable indicator of bacterial ventriculitis in patients with ventriculostomies.

    PubMed

    Hill, Emily; Bleck, Thomas P; Singh, Kamaljit; Ouyang, Bichun; Busl, Katharina M

    2017-06-01

    In a febrile patient with a ventriculostomy, diagnosing or excluding bacterial or microbial ventriculitis is difficult, as conventional markers in analysis of cerebrospinal fluid (CSF) are not applicable due to presence of blood and inflammation. CSF lactate has been shown to be a useful indicator of bacterial meningitis in CSF obtained via lumbar puncture, but little and heterogenous data exist on patients with ventriculostomies. We reviewed all CSF analyses obtained via ventriculostomy in patients admitted to our tertiary medical center between 2008 and 2013, and constructed receiver operating characteristic (ROC) curves to evaluate the accuracy of CSF lactate concentration in discriminating a positive CSF culture from a negative one in setting of ventriculostomy and prophylactic antibiosis. Among 467 CSF lactate values, there were 22 corresponding CSF cultures with bacterial growth. Sensitivities and specificities for CSF lactate at threshold values 3, 4, 5 and 6mmol/L showed sensitivity and specificity greater than 70% for CSF lactate threshold 4mmol/L. The lowest threshold value of 3mmol/L resulted in higher sensitivity of 81.8%, and the highest chosen threshold value resulted in high specificity of 94.2%, but these values had poor corresponding specificity and sensitivity, respectively. The area under the curve was 0.82 (95% CI 0.72, 0.91). Our data from a large sample of CSF studies in patients with ventriculostomy indicate that no single value of CSF lactate provided both sensitivity and specificity high enough to be regarded as reliable test. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Evaluation of the Architect HIV Ag/Ab Combo Assay in a low-prevalence setting: The role of samples with a low S/CO ratio.

    PubMed

    Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio

    2018-06-01

    The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Mortality risk prediction in burn injury: Comparison of logistic regression with machine learning approaches.

    PubMed

    Stylianou, Neophytos; Akbarov, Artur; Kontopantelis, Evangelos; Buchan, Iain; Dunn, Ken W

    2015-08-01

    Predicting mortality from burn injury has traditionally employed logistic regression models. Alternative machine learning methods have been introduced in some areas of clinical prediction as the necessary software and computational facilities have become accessible. Here we compare logistic regression and machine learning predictions of mortality from burn. An established logistic mortality model was compared to machine learning methods (artificial neural network, support vector machine, random forests and naïve Bayes) using a population-based (England & Wales) case-cohort registry. Predictive evaluation used: area under the receiver operating characteristic curve; sensitivity; specificity; positive predictive value and Youden's index. All methods had comparable discriminatory abilities, similar sensitivities, specificities and positive predictive values. Although some machine learning methods performed marginally better than logistic regression the differences were seldom statistically significant and clinically insubstantial. Random forests were marginally better for high positive predictive value and reasonable sensitivity. Neural networks yielded slightly better prediction overall. Logistic regression gives an optimal mix of performance and interpretability. The established logistic regression model of burn mortality performs well against more complex alternatives. Clinical prediction with a small set of strong, stable, independent predictors is unlikely to gain much from machine learning outside specialist research contexts. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  16. Assessing Breast Cancer Risk with an Artificial Neural Network

    PubMed

    Sepandi, Mojtaba; Taghdir, Maryam; Rezaianzadeh, Abbas; Rahimikazerooni, Salar

    2018-04-25

    Objectives: Radiologists face uncertainty in making decisions based on their judgment of breast cancer risk. Artificial intelligence and machine learning techniques have been widely applied in detection/recognition of cancer. This study aimed to establish a model to aid radiologists in breast cancer risk estimation. This incorporated imaging methods and fine needle aspiration biopsy (FNAB) for cyto-pathological diagnosis. Methods: An artificial neural network (ANN) technique was used on a retrospectively collected dataset including mammographic results, risk factors, and clinical findings to accurately predict the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: The network incorporating the selected features performed best (AUC = 0.955). Sensitivity and specificity of the ANN were respectively calculated as 0.82 and 0.90. In addition, negative and positive predictive values were respectively computed as 0.90 and 0.80. Conclusion: ANN has potential applications as a decision-support tool to help underperforming practitioners to improve the positive predictive value of biopsy recommendations. Creative Commons Attribution License

  17. Dengvaxia sensitizes seronegatives to vaccine enhanced disease regardless of age.

    PubMed

    Halstead, Scott B

    2017-11-07

    During a large scale clinical efficacy trial of the Sanofipasteur live-attenuated tetravalent dengue vaccine (Dengvaxia), features of hospitalized disease accompanying dengue infections in placebo recipients were closely similar to those in vaccinated children. However, the age specific hospitalization curves for these two populations differed. The curve for children vaccinated at ages 2-16 years closely resembled the 1981 age specific hospitalization rate curve for Cuban children infected with DENV 2 who were sensitized by a prior DENV 1 infection. The corresponding age specific hospitalization curve for placebos experiencing heterotypic secondary dengue infections peaked at age, 9-11 years. These differing epidemiological features support the conclusion that antibody dependent enhanced (ADE) dengue disease occurred in seronegatives who were sensitized by vaccine. As hospitalizations continue to occur in all age groups Dengvaxia consumers should be warned that sensitized vaccinated seronegatives will experience enhanced dengue disease into the forseeable future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Do Intracerebral Hemorrhage Nonexpanders Actually Expand Into the Ventricular Space?

    PubMed

    Dowlatshahi, Dar; Deshpande, Anirudda; Aviv, Richard I; Rodriguez-Luna, David; Molina, Carlos A; Blas, Yolanda Silva; Dzialowski, Imanuel; Kobayashi, Adam; Boulanger, Jean-Martin; Lum, Cheemun; Gubitz, Gordon J; Padma, Vasantha; Roy, Jayanta; Kase, Carlos S; Bhatia, Rohit; Hill, Michael D; Demchuk, Andrew M

    2018-01-01

    The computed tomographic angiography spot sign as a predictor of hematoma expansion is limited by its modest sensitivity and positive predictive value. It is possible that hematoma expansion in spot-positive patients is missed because of decompression of intracerebral hemorrhage (ICH) into the ventricular space. We hypothesized that revising hematoma expansion definitions to include intraventricular hemorrhage (IVH) expansion will improve the predictive performance of the spot sign. Our objectives were to determine the proportion of ICH nonexpanders who actually have IVH expansion, determine the proportion of false-positive spot signs that have IVH expansion, and compare the known predictive performance of the spot sign to a revised definition incorporating IVH expansion. We analyzed patients from the multicenter PREDICT ICH spot sign study. We defined hematoma expansion as ≥6 mL or ≥33% ICH expansion or >2 mL IVH expansion and compared spot sign performance using this revised definition with the conventional 6 mL/33% definition using receiver operating curve analysis. Of 311 patients, 213 did not meet the 6-mL/33% expansion definition (nonexpanders). Only 13 of 213 (6.1%) nonexpanders had ≥2 mL IVH expansion. Of the false-positive spot signs, 4 of 40 (10%) had >2 mL ventricular expansion. The area under the curve for spot sign to predict significant ICH expansion was 0.65 (95% confidence interval, 0.58-0.72), which was no different than when IVH expansion was added to the definition (area under the curve, 0.66; 95% confidence interval, 0.58-0.71). Although IVH expansion does indeed occur in a minority of ICH nonexpanders, its inclusion into a revised hematoma expansion definition does not alter the predictive performance of the spot sign. © 2017 American Heart Association, Inc.

  19. [Efficacy of absorbance ratio of ELISA antibodies [corrected] for hepatitis C virus of 3th generation in the prediction of viremia evaluated by PCR].

    PubMed

    Vázquez-Avila, Isidro; Vera-Peralta, Jorge Manuel; Alvarez-Nemegyei, José; Rodríguez-Carvajal, Otilia

    2007-01-01

    In order to decrease the burden of suffering and the costs derived from confirmatory molecular assays, a better strategy is badly needed to decrease the rate of false positive results of the enzyme-linked immunoassay (ELISA) for detection of hepatitis C virus (HCV) antibodies (Anti). To establish the best cutoff of the S/CO rate in subjects with a positive result of a microparticule, third generation ELISA assay for Anti-HCV, for predicting viremia as detected by polymerase chain reaction (PCR) assay. Using the result of the PCR assay as "gold standard", a ROC curve was build with the results of the S/CO rate values in subjects with a positive result for ELISA HCV assay. Fifty two subjects (30 male, 22 female, 40 +/- 12.5 years old) were included. Thirty four (65.3%) had a positive RNA HCV PCR assay. The area under the curve was 0.99 (95% CI: 0.98-1.0). The optimal cutoff for the S/CO rate was established in 29: sensitivity: 97%; specificity: 100%: PPV: 100%; NPV: 94%. Setting the cutoff of the S/CO in 29 results in a high predictive value for viremia as detected by PCR in subjects with a positive ELISA HVC assay. This knowledge may result in a better decision taking for the clinical follow up of those subjects with a positive result in the ELISA screening assay for HCV infection.

  20. SU-G-BRB-11: On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, P; Olaciregui-Ruiz, I; Mijnheer, B

    2016-06-15

    Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of themore » various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.« less

  1. The sensitivity of catchment hypsometry and hypsometric properties to DEM resolution and polynomial order

    NASA Astrophysics Data System (ADS)

    Liffner, Joel W.; Hewa, Guna A.; Peel, Murray C.

    2018-05-01

    Derivation of the hypsometric curve of a catchment, and properties relating to that curve, requires both use of topographical data (commonly in the form of a Digital Elevation Model - DEM), and the estimation of a functional representation of that curve. An early investigation into catchment hypsometry concluded 3rd order polynomials sufficiently describe the hypsometric curve, without the consideration of higher order polynomials, or the sensitivity of hypsometric properties relating to the curve. Another study concluded the hypsometric integral (HI) is robust against changes in DEM resolution, a conclusion drawn from a very limited sample size. Conclusions from these earlier studies have resulted in the adoption of methods deemed to be "sufficient" in subsequent studies, in addition to assumptions that the robustness of the HI extends to other hypsometric properties. This study investigates and demonstrates the sensitivity of hypsometric properties to DEM resolution, DEM type and polynomial order through assessing differences in hypsometric properties derived from 417 catchments and sub-catchments within South Australia. The sensitivity of hypsometric properties across DEM types and polynomial orders is found to be significant, which suggests careful consideration of the methods chosen to derive catchment hypsometric information is required.

  2. Signal processing system for electrotherapy applications

    NASA Astrophysics Data System (ADS)

    Płaza, Mirosław; Szcześniak, Zbigniew

    2017-08-01

    The system of signal processing for electrotherapeutic applications is proposed in the paper. The system makes it possible to model the curve of threshold human sensitivity to current (Dalziel's curve) in full medium frequency range (1kHz-100kHz). The tests based on the proposed solution were conducted and their results were compared with those obtained according to the assumptions of High Tone Power Therapy method and referred to optimum values. Proposed system has high dynamics and precision of mapping the curve of threshold human sensitivity to current and can be used in all methods where threshold curves are modelled.

  3. Fluorescence spectroscopy for diagnosis of squamous intraepithelial lesions of the cervix.

    PubMed

    Mitchell, M F; Cantor, S B; Ramanujam, N; Tortolero-Luna, G; Richards-Kortum, R

    1999-03-01

    To calculate receiver operating characteristic (ROC) curves for fluorescence spectroscopy in order to measure its performance in the diagnosis of squamous intraepithelial lesions (SILs) and to compare these curves with those for other diagnostic methods: colposcopy, cervicography, speculoscopy, Papanicolaou smear screening, and human papillomavirus (HPV) testing. Data from our previous clinical study were used to calculate ROC curves for fluorescence spectroscopy. Curves for other techniques were calculated from other investigators' reports. To identify these, a MEDLINE search for articles published from 1966 to 1996 was carried out, using the search terms "colposcopy," "cervicoscopy," "cervicography," "speculoscopy," "Papanicolaou smear," "HPV testing," "fluorescence spectroscopy," and "polar probe" in conjunction with the terms "diagnosis," "positive predictive value," "negative predictive value," and "receiver operating characteristic curve." We found 270 articles, from which articles were selected if they reported results of studies involving high-disease-prevalence populations, reported findings of studies in which colposcopically directed biopsy was the criterion standard, and included sufficient data for recalculation of the reported sensitivities and specificities. We calculated ROC curves for fluorescence spectroscopy using Bayesian and neural net algorithms. A meta-analytic approach was used to calculate ROC curves for the other techniques. Areas under the curves were calculated. Fluorescence spectroscopy using the neural net algorithm had the highest area under the ROC curve, followed by fluorescence spectroscopy using the Bayesian algorithm, followed by colposcopy, the standard diagnostic technique. Cervicography, Papanicolaou smear screening, and HPV testing performed comparably with each other but not as well as fluorescence spectroscopy and colposcopy. Fluorescence spectroscopy performs better than colposcopy and other techniques in the diagnosis of SILs. Because it also permits real-time diagnosis and has the potential of being used by inexperienced health care personnel, this technology holds bright promise.

  4. [Glycosylated hemoglobin A1c as a diagnostic test for diabetes mellitus in adolescents with overweight and obesity].

    PubMed

    Rivera-Hernández, Aleida; Zurita-Cruz, Jessie Nallely; Garrido-Magaña, Eulalia; Fiorentini-Fayad, Gigliola Margaretta; Nishimura-Meguro, Elisa

    2015-01-01

    In 2009 it was introduced a new diagnostic criteria based on hemoglobin A1c (HbA1c) greater than or equal to 6.5 % in the adult population; some studies suggest that the cutoff may be smaller in pediatric population. The objective was to determine the utility of HbA1c greater than or equal to 6.5 % as a diagnostic test for DM in Mexican adolescents with overweight or obesity. Full somatometry was performed. Also, Tanner stage, blood pressure, blood glucose, glucose tolerance curve (GTC) and HbA1c were analyzed. Specificity, sensitivity, positive and negative predictive values and ROC curve were calculated for the diagnosis of DM with HbA1c. 109 adolescents between 10 and 16 years referred for obesity or overweight plus comorbidities were studied; 58 % were females, the age was of 13 ± 1.74 years, the BMI percentile 95.3, and the HbA1c 5.73 ± 0.9 %. It was made a diagnosis of DM in 9 cases (8.3 %), prediabetes in 8 (7.3 %) and normal glucose tolerance in 92 (84.4 %). The HbA1c mean was 5.6 ± 0.04, 5.7 ± 0.4, and 5.6 ± 0.73 %, respectively. HbA1c greater than or equal to 6.5 % had a sensitivity of 12.5 %, a specificity of 89.8 %, a PPV of 10.65 and a NPV of 14.28. The best cutoff point for diagnosing DM through ROC curve was 5.45 %, with a sensitivity of 62.5 %, a specificity of 57.1 %, PPV 2.53 and NPV 33.3. The level of HbA1c greater than or equal to 6.5 % had low sensitivity and specificity for the diagnosis of DM. A lower cutoff point is insufficient to use HbA1c as a diagnostic criterion. These results are consistent with the ones of other journals.

  5. Mathematical model of a DIC position sensing system within an optical trap

    NASA Astrophysics Data System (ADS)

    Wulff, Kurt D.; Cole, Daniel G.; Clark, Robert L.

    2005-08-01

    The quantitative study of displacements and forces of motor proteins and processes that occur at the microscopic level and below require a high level of sensitivity. For optical traps, two techniques for position sensing have been accepted and used quite extensively: quadrant photodiodes and an interferometric position sensing technique based on DIC imaging. While quadrant photodiodes have been studied in depth and mathematically characterized, a mathematical characterization of the interferometric position sensor has not been presented to the authors' knowledge. The interferometric position sensing method works off of the DIC imaging capabilities of a microscope. Circularly polarized light is sent into the microscope and the Wollaston prism used for DIC imaging splits the beam into its orthogonal components, displacing them by a set distance determined by the user. The distance between the axes of the beams is set so the beams overlap at the specimen plane and effectively share the trapped microsphere. A second prism then recombines the light beams and the exiting laser light's polarization is measured and related to position. In this paper we outline the mathematical characterization of a microsphere suspended in an optical trap using a DIC position sensing method. The sensitivity of this mathematical model is then compared to the QPD model. The mathematical model of a microsphere in an optical trap can serve as a calibration curve for an experimental setup.

  6. Transperineal ultrasound compared to evacuation proctography for diagnosing enteroceles and intussusceptions.

    PubMed

    Weemhoff, M; Kluivers, K B; Govaert, B; Evers, J L H; Kessels, A G H; Baeten, C G

    2013-03-01

    This study concerns the level of agreement between transperineal ultrasound and evacuation proctography for diagnosing enteroceles and intussusceptions. In a prospective observational study, 50 consecutive women who were planned to have an evacuation proctography underwent transperineal ultrasound too. Sensitivity, specificity, positive (PPV) and negative predictive value, as well as the positive and negative likelihood ratio of transperineal ultrasound were assessed in comparison to evacuation proctography. To determine the interobserver agreement of transperineal ultrasound, the quadratic weighted kappa was calculated. Furthermore, receiver operating characteristic curves were generated to show the diagnostic capability of transperineal ultrasound. For diagnosing intussusceptions (PPV 1.00), a positive finding on transperineal ultrasound was predictive of an abnormal evacuation proctography. Sensitivity of transperineal ultrasound was poor for intussusceptions (0.25). For diagnosing enteroceles, the positive likelihood ratio was 2.10 and the negative likelihood ratio, 0.85. There are many false-positive findings of enteroceles on ultrasonography (PPV 0.29). The interobserver agreement of the two ultrasonographers assessed as the quadratic weighted kappa of diagnosing enteroceles was 0.44 and that of diagnosing intussusceptions was 0.23. An intussusception on ultrasound is predictive of an abnormal evacuation proctography. For diagnosing enteroceles, the diagnostic quality of transperineal ultrasound was limited compared to evacuation proctography.

  7. Determining vehicle operating speed and lateral position along horizontal curves using linear mixed-effects models.

    PubMed

    Fitzsimmons, Eric J; Kvam, Vanessa; Souleyrette, Reginald R; Nambisan, Shashi S; Bonett, Douglas G

    2013-01-01

    Despite recent improvements in highway safety in the United States, serious crashes on curves remain a significant problem. To assist in better understanding causal factors leading to this problem, this article presents and demonstrates a methodology for collection and analysis of vehicle trajectory and speed data for rural and urban curves using Z-configured road tubes. For a large number of vehicle observations at 2 horizontal curves located in Dexter and Ames, Iowa, the article develops vehicle speed and lateral position prediction models for multiple points along these curves. Linear mixed-effects models were used to predict vehicle lateral position and speed along the curves as explained by operational, vehicle, and environmental variables. Behavior was visually represented for an identified subset of "risky" drivers. Linear mixed-effect regression models provided the means to predict vehicle speed and lateral position while taking into account repeated observations of the same vehicle along horizontal curves. Speed and lateral position at point of entry were observed to influence trajectory and speed profiles. Rural horizontal curve site models are presented that indicate that the following variables were significant and influenced both vehicle speed and lateral position: time of day, direction of travel (inside or outside lane), and type of vehicle.

  8. Evaluation of ascitic soluble human leukocyte antigen-G for distinguishing malignant ascites from benign ascites.

    PubMed

    Sun, Juan; Chang, Yan-Xiang; Niu, Chun-Yan

    2017-11-01

    The overexpression of soluble human leukocyte antigen-G is associated with malignant tumours. The purpose of our study was to detect soluble human leukocyte antigen-G concentrations in ascites and to evaluate the value of ascitic soluble human leukocyte antigen-G for the diagnosis of malignant ascites. Enzyme-linked immunosorbent assay was used to detect soluble human leukocyte antigen-G levels in 64 patients with malignant ascites and 30 patients with benign ascites. Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of ascitic soluble human leukocyte antigen-G for the detection of malignant ascites. Ascitic soluble human leukocyte antigen-G levels were significantly higher in the malignant ascites group than in the benign ascites group (20.718 ± 3.215 versus 12.467 ± 3.678 µg/L, t = 7.425, p < 0.001). The area under the receiver operating characteristic curve for ascitic soluble human leukocyte antigen-G was 0.957 (95% confidence interval, 0.872-0.992). At a cut-off value of 19.60 µg/L, the sensitivity and specificity of ascitic soluble human leukocyte antigen-G were 87.5% (95% confidence interval, 71.0%-96.5%) and 100% (95% confidence interval, 88.4%-100%), respectively. With respect to area under the receiver operating characteristic curve, sensitivity and specificity, ascitic carcinoembryonic antigen (0.810, 68.75% and 83.33%, respectively) and carbohydrate antigen 19-9 (0.710, 65.63% and 70%, respectively) significantly differed (all p < 0.05). In malignant ascites that were cytology-negative and biopsy-positive, the rate of positivity for ascitic soluble human leukocyte antigen-G was 75%, which was higher than the corresponding rates for ascitic carcinoembryonic antigen (31.25%) and carbohydrate antigen 19-9 (6.25%; both p < 0.05). In conclusion, The detection of ascitic soluble human leukocyte antigen-G exhibited good performance for diagnosing malignant ascites, and particularly those that were cytology-negative and biopsy-positive.

  9. Intensity of hydrostimulation for the induction of root hydrotropism and its sensing by the root cap

    NASA Technical Reports Server (NTRS)

    Takahashi, H.; Scott, T. K.

    1993-01-01

    Roots of Pisum sativum L. and Zea mays L. were exposed to different moisture gradients established by placing both wet cheesecloth (hydrostimulant) and saturated aqueous solutions of various salts in a closed chamber. Atmospheric conditions with different relative humidity (RH) in a range between 98 and 86% RH were obtained at root level, 2 to 3mm from the water-saturated hydrostimulant. Roots of Silver Queen corn placed vertically with the tips down curved sideways toward the hydrostimulant in response to approximately 94% RH but did not respond positively to RH higher than approximately 95%. The positive hydrotropic response increased linearly as RH was lowered from 95 to 90%. A maximum response was observed at RH between 90 and 86%. However, RH required for the induction of hydrotropism as well as the responsiveness differed among plant species used; gravitropically sensitive roots appeared to require a somewhat greater moisture gradient for the induction of hydrotropism. Decapped roots of corn failed to curve hydrotropically, suggesting the root cap as a major site of hydrosensing.

  10. Validation of 5-item and 2-item questionnaires in Chinese version of Dizziness Handicap Inventory for screening objective benign paroxysmal positional vertigo.

    PubMed

    Chen, Wei; Shu, Liang; Wang, Qian; Pan, Hui; Wu, Jing; Fang, Jie; Sun, Xu-Hong; Zhai, Yu; Dong, You-Rong; Liu, Jian-Ren

    2016-08-01

    As possible candidate screening instruments for benign paroxysmal positional vertigo (BPPV), studies to validate the Dizziness Handicap Inventory (DHI) sub-scale (5-item and 2-item) and total scores are rare in China. From May 2014 to December 2014, 108(55 with and 53 without BPPV) patients complaining of episodic vertigo in the past week from a vertigo outpatient clinic were enrolled for DHI evaluation, as well as demographic and other clinical data. Objective BPPV was subsequently determined by positional evoking maneuvers under the record of optical Frenzel glasses. Cronbach's coefficient α was used to evaluate the reliability of psychometric scales. The validity of DHI total, 5-item and 2-item questionnaires to screen for BPPV was assessed by receiver operating characteristic (ROC) curves. It revealed that the DHI 5-item questionnaire had good internal consistency (Cronbach's coefficient α = 0.72). Area under the curve of total DHI, 5-item and 2-item scores for discriminating BPPV from those without was 0.678 (95 % CI 0.578-0.778), 0.873(95 % CI 0.807-0.940) and 0.895(95 % CI 0.836-0.953), respectively. It revealed 74.5 % sensitivity and 88.7 % specificity in separating BPPV and those without, with a cutoff value of 12 in the 5-item questionnaire. The corresponding rate of sensitivity and specificity was 78.2 and 88.7 %, respectively, with a cutoff value of 6 in 2-item questionnaire. The present study indicated that both 5-item and 2-item questionnaires in the Chinese version of DHI may be more valid than DHI total score for screening objective BPPV and merit further application in clinical practice in China.

  11. [Evaluation of serology as a diagnostic method for Helicobacter pylori infection in the local population of Guayaquil].

    PubMed

    Zapatier, Jorge A; Gómez, Néstor A; Vargas, Paola E; Maya, Susana V

    2007-06-01

    The infection with Helicobacter pylori (H. pylori), and the diagnostic efficacy of the serologic tests has certain variability among the different geographic regions. The objective of the present work was to find the local validation of serological methods for diagnosis of H. pylori infection and to determine the best cutoff value for the local population. Forty-eight patients were evaluated, 27 males and 21 females, with a mean age of 29.2 years. On each patient, 3 tests for H. pylori diagnosis were performed: IgG serology, IgA serology and histology. We performed IgG and IgA serologic test for H. pylori infection and a histological examination for each patient. Efficacy parameters as well as the ROC curve were obtained for the IgG and IgA serology using histology as the gold standard. The cutoff point with the highest efficacy for IgG serology was 16 U/ml (sensitivity 81%, specificity 65%, positive predictive value 81%, negative predictive value 65%, and accuracy 75%), and for IgA serology was 17 U/ml (sensitivity 61%, specificity 53%, positive predictive value 70%, negative predictive value 43%, and accuracy 58%). The area under the curve was 67.1% (CI 95%: 50 to 84.1) and 54.4% (CI 95%: 38.3 to 72.5) for IgG and IgA respectively. The serology is a valuable tool in our population with high prevalence of H. pylori, especially due to its low cost and easy performance, but a reduction ofthe cutoff value was necessary to obtain more sensibility and a more adequate identification of true positives cases.

  12. Molecular and Culture-Based Bronchoalveolar Lavage Fluid Testing for the Diagnosis of Cytomegalovirus Pneumonitis.

    PubMed

    Tan, Susanna K; Burgener, Elizabeth B; Waggoner, Jesse J; Gajurel, Kiran; Gonzalez, Sarah; Chen, Sharon F; Pinsky, Benjamin A

    2016-01-01

    Background.  Cytomegalovirus (CMV) is a major cause of morbidity and mortality in immunocompromised patients, with CMV pneumonitis among the most severe manifestations of infection. Although bronchoalveolar lavage (BAL) samples are frequently tested for CMV, the clinical utility of such testing remains uncertain. Methods.  Retrospective analysis of adult patients undergoing BAL testing via CMV polymerase chain reaction (PCR), shell vial culture, and conventional viral culture between August 2008 and May 2011 was performed. Cytomegalovirus diagnostic methods were compared with a comprehensive definition of CMV pneumonitis that takes into account signs and symptoms, underlying host immunodeficiency, radiographic findings, and laboratory results. Results.  Seven hundred five patients underwent 1077 bronchoscopy episodes with 1090 BAL specimens sent for CMV testing. Cytomegalovirus-positive patients were more likely to be hematopoietic cell transplant recipients (26% vs 8%, P < .0001) and less likely to have an underlying condition not typically associated with lung disease (3% vs 20%, P < .0001). Histopathology was performed in only 17.3% of CMV-positive bronchoscopy episodes. When CMV diagnostic methods were evaluated against the comprehensive definition, the sensitivity and specificity of PCR, shell vial culture, and conventional culture were 91.3% and 94.6%, 54.4% and 97.4%, and 28.3% and 96.5%, respectively. Compared with culture, PCR provided significantly higher sensitivity and negative predictive value (P ≤ .001), without significantly lower positive predictive value. Cytomegalovirus quantitation did not improve test performance, resulting in a receiver operating characteristic curve with an area under the curve of 0.53. Conclusions.  Cytomegalovirus PCR combined with a comprehensive clinical definition provides a pragmatic approach for the diagnosis of CMV pneumonitis.

  13. Novel Interpretation of Molecular Diagnosis of Congenital Toxoplasmosis According to Gestational Age at the Time of Maternal Infection

    PubMed Central

    Sterkers, Yvon; Pratlong, Francine; Albaba, Sahar; Loubersac, Julie; Picot, Marie-Christine; Pretet, Vanessa; Issert, Eric; Boulot, Pierre

    2012-01-01

    From a prospective cohort of 344 women who seroconverted for toxoplasmosis during pregnancy, 344 amniotic fluid, 264 placenta, and 216 cord blood samples were tested for diagnosis of congenital toxoplasmosis using the same PCR assay. The sensitivity and negative predictive value of the PCR assay using amniotic fluid were 86.3% and 97.2%, respectively, and both specificity and positive predictive value were 100%. Using placenta and cord blood, sensitivities were 79.5% and 21.2%, and specificities were 92% and 100%, respectively. In addition, the calculation of pretest and posttest probabilities and the use of logistic regression allowed us to obtain curves that give a dynamic interpretation of the risk of congenital toxoplasmosis according to gestational age at maternal infection, as represented by the three sample types (amniotic fluid, placenta, and cord blood). Two examples are cited here: for a maternal infection at 25 weeks of amenorrhea, a negative result of prenatal diagnosis allowed estimation of the probability of congenital toxoplasmosis at 5% instead of an a priori (pretest) risk estimate of 33%. For an infection at 10 weeks of amenorrhea associated with a pretest congenital toxoplasmosis risk of 7%, a positive PCR result using placenta at birth yields a risk increase to 43%, while a negative result damps down the risk to 0.02%. Thus, with a molecular diagnosis performing at a high level, and in spite of the persistence of false negatives, posttest risk curves using both negative and positive results prove highly informative, allowing a better assessment of the actual risk of congenital toxoplasmosis and finally an improved decision guide to treatment. PMID:23035201

  14. Surface sensitization mechanism on negative electron affinity p-GaN nanowires

    NASA Astrophysics Data System (ADS)

    Diao, Yu; Liu, Lei; Xia, Sihao; Feng, Shu; Lu, Feifei

    2018-03-01

    The surface sensitization is the key to prepare negative electron affinity photocathode. The thesis emphasizes on the study of surface sensitization mechanism of p-type doping GaN nanowires utilizing first principles based on density function theory. The adsorption energy, work function, dipole moment, geometry structure, electronic structure and optical properties of Mg-doped GaN nanowires surfaces with various coverages of Cs atoms are investigated. The GaN nanowire with Mg doped in core position is taken as the sensitization base. At the initial stage of sensitization, the best adsorption site for Cs atom on GaN nanowire surface is BN, the bridge site of two adjacent N atoms. Surface sensitization generates a p-type internal surface with an n-type surface state, introducing a band bending region which can help reduce surface barrier and work function. With increasing Cs coverage, work functions decrease monotonously and the "Cs-kill" phenomenon disappears. For Cs coverage of 0.75 ML and 1 ML, the corresponding sensitization systems reach negative electron affinity state. Through surface sensitization, the absorption curves are red shifted and the absorption coefficient is cut down. All theoretical calculations can guide the design of negative electron affinity Mg doped GaN nanowires photocathode.

  15. Sensitivity of Fit Indices to Misspecification in Growth Curve Models

    ERIC Educational Resources Information Center

    Wu, Wei; West, Stephen G.

    2010-01-01

    This study investigated the sensitivity of fit indices to model misspecification in within-individual covariance structure, between-individual covariance structure, and marginal mean structure in growth curve models. Five commonly used fit indices were examined, including the likelihood ratio test statistic, root mean square error of…

  16. A synergistic role of ischemia modified albumin and high-sensitivity troponin T in the early diagnosis of acute coronary syndrome

    PubMed Central

    Mehta, Mihir D.; Marwah, Simbita A.; Ghosh, S.; Shah, Hitesh N.; Trivedi, Amit P.; Haridas, N.

    2015-01-01

    Aim: The aim was to evaluate the role of high sensitivity troponin T and ischemia modified albumin (IMA) and in the early diagnosis of acute coronary syndrome (ACS). Materials and Methods: This was a cross-sectional study that comprised of 120 individuals of which 75 were cases and 45 healthy controls. On the basis of clinical history and 12-lead electrocardiogram, initial diagnosis of ACS was made in the cases. High sensitive cardiac troponin T (hs-cTnT) and IMA were measured in all the individuals. Results: Levels of IMA were significantly higher in patients of ACS as compared to those in control group (means: 101.83 [95% confidence interval (CI): 91.96–111.70] vs. 41.11 [95% CI: 38.55–43.67]). By taking the cut-off as >65.23 U/mL for IMA, which was obtained from receiver operating characteristic (ROC) curve, the sensitivity was 91.3%, specificity was 81.1%, positive predictive value (PPV) was 74.4%, and negative predictive value (NPV) was 93.9%. Positive likelihood ratio was 4.83 while negative likelihood ratio was 0.11, whereas the corresponding values in case of hs-cTnT were 95.6% (95% CI: 85.2–99.5), 61.3% (95% CI: 49.5–72.6), 59.7%, 95.8%, 2.47 and 0.07 by taking cut-off as >14 pg/mL. The area under the ROC curves (AUC) of IMA and hs-cTnT at 0–6 h were 0.932 (95% CI: 0.87–0.97, P < 0.001) and 0.797 (95% CI: 0.71–0.86, P < 0.001), respectively. The logistic model combining the two markers yielded sensitivity, specificity, PPV, and NPV of 95.7%, 81.1%, 88.6%, and 92.5% respectively. Conclusion: hs-cTnT and IMA may be useful tools for risk stratification of ACS and can be used together with better accuracy in the early diagnosis of ACS. PMID:26985418

  17. Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side.

    PubMed

    Apa, Hurşit; Gözmen, Salih; Keskin-Gözmen, Şükran; Aslan, Fatma; Bayram, Nuri; Devrim, İlker

    2016-01-01

    Measurement from axillary site with digital thermometer has been accepted as the most accurate method. But this method is time consuming. Tympanic and forehead measurements are often used but don't always seem to be more appropriate. Another site, umbilical region, could be an alternative site. This study aims to compare the measurements with axillary digital thermometer and non-contact infrared thermometers at sites from umbilicus and forehead to determine whether umbilical site could be used accurately in children. For each method, 2,048 measurements in total were performed. Using axillary method as gold standard, with a cut-off temperature of 38oC, the sensitivities and specificities, positive and negative predictive values of umbilical and forehead temperatures and area under the ROC curve were determined in non obese children. There was a significant positive correlation between axillary and umbilical temperatures with a correlation coefficient of 0.78. The average difference between the mean of both axillary and umbilical temperatures was -0.47 ± 0.65°C. The Bland-Altman plot showed good accuracy with only 2.5 % of the readings falling outside the 95% level of confidence. Umbilical measurements showed sensitivity of 71.7% and specificity of 95.8%. The area under the ROC curve was 0.93. The easy application may lead noncontact measurements from umbilicus site to be the preferable method for health care providers, but agreement limits mentioned in this study should be considered.

  18. [Diagnosis of obstructive sleep apnea syndrome using pulse oximeter derived photoplethysmographic signals].

    PubMed

    Pan, H; Huang, G P; Ren, R; Lei, F; Tang, X D

    2016-05-24

    To evaluate the diagnosis value of photoplethysmography (PPG)-based device for detecting obstructive sleep apnea syndrome. Patients who visited sleep medicine center in West China hospital from March 2014 to March 2015 with a main complain of snoring were selected into this study, and they were simultaneously monitored with the PPG-based device while undergoing polysomnography (PSG). Using PSG as"gold standard", the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) as well as corresponding areas under the receiver operator curves for an apnea hypopnea index (AHI) ≥5/h, ≥15/h and ≥30/h were calculated for PPG. Valid results were available for 93 subjects, among them there were 64 men and 29 women with a mean age of (44±13) years old.There were no significant difference between total sleep time, wake time after sleep onset, AHI and oxygen saturation derived by PPG and PSG.Positive correlation was found between PPG-derived and PSG-derived AHI (r=0.945). For AHI≥5/h, ≥15/h and ≥30/h respectively according PSG, sensitivity was 93%, 88%, 92%, specificity was 79%, 93%, 95%, PPV was 95%, 97%, 96%, NPV 75%, 76%, 91% for PPG. The corresponding areas under the receiver operator characteristic curves were 0.981, 0.996 and 0.995 respectively. PPG-derived data is consistent with simultaneous in-lab PSG in the diagnosis of obstructive sleep apnea syndrome.

  19. Clinical utility of balloon expulsion test for functional defecation disorders

    PubMed Central

    2016-01-01

    Purpose I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Methods Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Results Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. Conclusion SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD. PMID:26878016

  20. Clinical utility of balloon expulsion test for functional defecation disorders.

    PubMed

    Seong, Moo-Kyung

    2016-02-01

    I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD.

  1. The NINJA-2 project: detecting and characterizing gravitational waveforms modelled using numerical binary black hole simulations

    NASA Astrophysics Data System (ADS)

    Aasi, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Accadia, T.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Affeldt, C.; Agathos, M.; Aggarwal, N.; Aguiar, O. D.; Ain, A.; Ajith, P.; Alemic, A.; Allen, B.; Allocca, A.; Amariutei, D.; Andersen, M.; Anderson, R.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C.; Areeda, J.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Austin, L.; Aylott, B. E.; Babak, S.; Baker, P. T.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barbet, M.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bauchrowitz, J.; Bauer, Th S.; Behnke, B.; Bejger, M.; Beker, M. G.; Belczynski, C.; Bell, A. S.; Bell, C.; Bergmann, G.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Beyersdorf, P. T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biscans, S.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Bloemen, S.; Blom, M.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogaert, G.; Bogan, C.; Bond, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, Sukanta; Bosi, L.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brückner, F.; Buchman, S.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Burman, R.; Buskulic, D.; Buy, C.; Cadonati, L.; Cagnoli, G.; Calderón Bustillo, J.; Calloni, E.; Camp, J. B.; Campsie, P.; Cannon, K. C.; Canuel, B.; Cao, J.; Capano, C. D.; Carbognani, F.; Carbone, L.; Caride, S.; Castiglia, A.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Celerier, C.; Cella, G.; Cepeda, C.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chamberlin, S. J.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Chen, X.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Chow, J.; Christensen, N.; Chu, Q.; Chua, S. S. Y.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C.; Colombini, M.; Cominsky, L.; Constancio, M., Jr.; Conte, A.; Cook, D.; Corbitt, T. R.; Cordier, M.; Cornish, N.; Corpuz, A.; Corsi, A.; Costa, C. A.; Coughlin, M. W.; Coughlin, S.; Coulon, J.-P.; Countryman, S.; Couvares, P.; Coward, D. M.; Cowart, M.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dahl, K.; Dal Canton, T.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dattilo, V.; Daveloza, H.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; Dayanga, T.; Debreczeni, G.; Degallaix, J.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dereli, H.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Dhurandhar, S.; Díaz, M.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Virgilio, A.; Donath, A.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dossa, S.; Douglas, R.; Downes, T. P.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Dwyer, S.; Eberle, T.; Edo, T.; Edwards, M.; Effler, A.; Eggenstein, H.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Endrőczi, G.; Essick, R.; Etzel, T.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Favata, M.; Fehrmann, H.; Fejer, M. M.; Feldbaum, D.; Feroz, F.; Ferrante, I.; Ferrini, F.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Fisher, R. P.; Flaminio, R.; Fournier, J.-D.; Franco, S.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gair, J.; Gammaitoni, L.; Gaonkar, S.; Garufi, F.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, C.; Gleason, J.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gordon, N.; Gorodetsky, M. L.; Gossan, S.; Goßler, S.; Gouaty, R.; Gräf, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Groot, P.; Grote, H.; Grover, K.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gushwa, K.; Gustafson, E. K.; Gustafson, R.; Hammer, D.; Hammond, G.; Hanke, M.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hart, M.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Heidmann, A.; Heintze, M.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Heptonstall, A. W.; Heurs, M.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Hooper, S.; Hopkins, P.; Hosken, D. J.; Hough, J.; Howell, E. J.; Hu, Y.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh, M.; Huynh-Dinh, T.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Iyer, B. R.; Izumi, K.; Jacobson, M.; James, E.; Jang, H.; Jaranowski, P.; Ji, Y.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; K, Haris; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Karlen, J.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kawabe, K.; Kawazoe, F.; Kéfélian, F.; Keiser, G. M.; Keitel, D.; Kelley, D. B.; Kells, W.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, C.; Kim, K.; Kim, N.; Kim, N. G.; Kim, Y.-M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Koehlenbeck, S.; Kokeyama, K.; Kondrashov, V.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kremin, A.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, A.; Kumar, P.; Kumar, R.; Kuo, L.; Kutynia, A.; Kwee, P.; Landry, M.; Lantz, B.; Larson, S.; Lasky, P. D.; Lawrie, C.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lebigot, E. O.; Lee, C.-H.; Lee, H. K.; Lee, H. M.; Lee, J.; Leonardi, M.; Leong, J. R.; Le Roux, A.; Leroy, N.; Letendre, N.; Levin, Y.; Levine, B.; Lewis, J.; Li, T. G. F.; Libbrecht, K.; Libson, A.; Lin, A. C.; Littenberg, T. B.; Litvine, V.; Lockerbie, N. A.; Lockett, V.; Lodhia, D.; Loew, K.; Logue, J.; Lombardi, A. L.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Lubinski, M. J.; Lück, H.; Luijten, E.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macarthur, J.; Macdonald, E. P.; MacDonald, T.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magana-Sandoval, F.; Mageswaran, M.; Maglione, C.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Manca, G. M.; Mandel, I.; Mandic, V.; Mangano, V.; Mangini, N.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Martinelli, L.; Martynov, D.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIver, J.; McLin, K.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Meinders, M.; Melatos, A.; Mendell, G.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyers, P.; Miao, H.; Michel, C.; Mikhailov, E. E.; Milano, L.; Milde, S.; Miller, J.; Minenkov, Y.; Mingarelli, C. M. F.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Moesta, P.; Mohan, M.; Mohapatra, S. R. P.; Moraru, D.; Moreno, G.; Morgado, N.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nagy, M. F.; Nanda Kumar, D.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Necula, V.; Nelemans, G.; Neri, I.; Neri, M.; Newton, G.; Nguyen, T.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Ochsner, E.; O'Dell, J.; Oelker, E.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oppermann, P.; O'Reilly, B.; O'Shaughnessy, R.; Osthelder, C.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Padilla, C.; Pai, A.; Palashov, O.; Palomba, C.; Pan, H.; Pan, Y.; Pankow, C.; Paoletti, F.; Paoletti, R.; Papa, M. A.; Paris, H.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Pedraza, M.; Penn, S.; Perreca, A.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pierro, V.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poeld, J.; Poggiani, R.; Poteomkin, A.; Powell, J.; Prasad, J.; Premachandra, S.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Qin, J.; Quetschke, V.; Quintero, E.; Quiroga, G.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Raja, S.; Rajalakshmi, G.; Rakhmanov, M.; Ramet, C.; Ramirez, K.; Rapagnani, P.; Raymond, V.; Re, V.; Read, J.; Reed, C. M.; Regimbau, T.; Reid, S.; Reitze, D. H.; Rhoades, E.; Ricci, F.; Riles, K.; Robertson, N. A.; Robinet, F.; Rocchi, A.; Rodruck, M.; Rolland, L.; Rollins, J. G.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Salemi, F.; Sammut, L.; Sandberg, V.; Sanders, J. R.; Sannibale, V.; Santiago-Prieto, I.; Saracco, E.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R.; Scheuer, J.; Schilling, R.; Schnabel, R.; Schofield, R. M. S.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D.; Shah, S.; Shahriar, M. S.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siellez, K.; Siemens, X.; Sigg, D.; Simakov, D.; Singer, A.; Singer, L.; Singh, R.; Sintes, A. M.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Son, E. J.; Sorazu, B.; Souradeep, T.; Sperandio, L.; Staley, A.; Stebbins, J.; Steinlechner, J.; Steinlechner, S.; Stephens, B. C.; Steplewski, S.; Stevenson, S.; Stone, R.; Stops, D.; Strain, K. A.; Straniero, N.; Strigin, S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tarabrin, S. P.; Taylor, R.; ter Braack, A. P. M.; Thirugnanasambandam, M. P.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, V.; Tokmakov, K. V.; Tomlinson, C.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C. V.; Torrie, C. I.; Travasso, F.; Traylor, G.; Tse, M.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Urbanek, K.; Vahlbruch, H.; Vajente, G.; Valdes, G.; Vallisneri, M.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van der Sluys, M. V.; van Heijningen, J.; van Veggel, A. A.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Verma, S. S.; Vetrano, F.; Viceré, A.; Vincent-Finley, R.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vousden, W. D.; Vyachanin, S. P.; Wade, A.; Wade, L.; Wade, M.; Walker, M.; Wallace, L.; Wang, M.; Wang, X.; Ward, R. L.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wiesner, K.; Wilkinson, C.; Williams, K.; Williams, L.; Williams, R.; Williams, T.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M.; Winkler, W.; Wipf, C. C.; Wiseman, A. G.; Wittel, H.; Woan, G.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yancey, C. C.; Yang, H.; Yang, Z.; Yoshida, S.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, Fan; Zhang, L.; Zhao, C.; Zhu, X. J.; Zucker, M. E.; Zuraw, S.; Zweizig, J.; Boyle, M.; Brügmann, B.; Buchman, L. T.; Campanelli, M.; Chu, T.; Etienne, Z. B.; Hannam, M.; Healy, J.; Hinder, I.; Kidder, L. E.; Laguna, P.; Liu, Y. T.; London, L.; Lousto, C. O.; Lovelace, G.; MacDonald, I.; Marronetti, P.; Mösta, P.; Müller, D.; Mundim, B. C.; Nakano, H.; Paschalidis, V.; Pekowsky, L.; Pollney, D.; Pfeiffer, H. P.; Ponce, M.; Pürrer, M.; Reifenberger, G.; Reisswig, C.; Santamaría, L.; Scheel, M. A.; Shapiro, S. L.; Shoemaker, D.; Sopuerta, C. F.; Sperhake, U.; Szilágyi, B.; Taylor, N. W.; Tichy, W.; Tsatsin, P.; Zlochower, Y.

    2014-06-01

    The Numerical INJection Analysis (NINJA) project is a collaborative effort between members of the numerical relativity and gravitational-wave (GW) astrophysics communities. The purpose of NINJA is to study the ability to detect GWs emitted from merging binary black holes (BBH) and recover their parameters with next-generation GW observatories. We report here on the results of the second NINJA project, NINJA-2, which employs 60 complete BBH hybrid waveforms consisting of a numerical portion modelling the late inspiral, merger, and ringdown stitched to a post-Newtonian portion modelling the early inspiral. In a ‘blind injection challenge’ similar to that conducted in recent Laser Interferometer Gravitational Wave Observatory (LIGO) and Virgo science runs, we added seven hybrid waveforms to two months of data recoloured to predictions of Advanced LIGO (aLIGO) and Advanced Virgo (AdV) sensitivity curves during their first observing runs. The resulting data was analysed by GW detection algorithms and 6 of the waveforms were recovered with false alarm rates smaller than 1 in a thousand years. Parameter-estimation algorithms were run on each of these waveforms to explore the ability to constrain the masses, component angular momenta and sky position of these waveforms. We find that the strong degeneracy between the mass ratio and the BHs’ angular momenta will make it difficult to precisely estimate these parameters with aLIGO and AdV. We also perform a large-scale Monte Carlo study to assess the ability to recover each of the 60 hybrid waveforms with early aLIGO and AdV sensitivity curves. Our results predict that early aLIGO and AdV will have a volume-weighted average sensitive distance of 300 Mpc (1 Gpc) for 10M⊙ + 10M⊙ (50M⊙ + 50M⊙) BBH coalescences. We demonstrate that neglecting the component angular momenta in the waveform models used in matched-filtering will result in a reduction in sensitivity for systems with large component angular momenta. This reduction is estimated to be up to ˜15% for 50M⊙ + 50M⊙ BBH coalescences with almost maximal angular momenta aligned with the orbit when using early aLIGO and AdV sensitivity curves.

  2. Identifying Children at Risk of High Myopia Using Population Centile Curves of Refraction.

    PubMed

    Chen, Yanxian; Zhang, Jian; Morgan, Ian G; He, Mingguang

    2016-01-01

    To construct reference centile curves of refraction based on population-based data as an age-specific severity scale to evaluate their efficacy as a tool for identifying children at risk of developing high myopia in a longitudinal study. Data of 4218 children aged 5-15 years from the Guangzhou Refractive Error Study in Children (RESC) study, and 354 first-born twins from the Guangzhou Twin Eye Study (GTES) with annual visit were included in the analysis. Reference centile curves for refraction were constructed using a quantile regression model based on the cycloplegic refraction data from the RESC. The risk of developing high myopia (spherical equivalent ≤ -6 diopters [D]) was evaluated as a diagnostic test using the twin follow-up data. The centile curves suggested that the 3rd, 5th, and 10th percentile decreased from -0.25 D, 0.00 D and 0.25 D in 5 year-olds to -6.00 D, -5.65D and -4.63 D in 15 year-olds in the population-based data from RESC. In the GTES cohort, the 5th centile showed the most effective diagnostic value with a sensitivity of 92.9%, a specificity of 97.9% and a positive predictive value (PPV) of 65.0% in predicting high myopia onset (≤-6.00D) before the age of 15 years. The PPV was highest (87.5%) in 3rd centile but with only 50.0% sensitivity. The Mathew's correlation coefficient of 5th centile in predicting myopia of -6.0D/-5.0D/-4.0D by age of 15 was 0.77/0.51/0.30 respectively. Reference centile curves provide an age-specific estimation on a severity scale of refractive error in school-aged children. Children located under lower percentiles at young age were more likely to have high myopia at 15 years or probably in adulthood.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simonen, E.P.; Johnson, K.I.; Simonen, F.A.

    The Vessel Integrity Simulation Analysis (VISA-II) code was developed to allow calculations of the failure probability of a reactor pressure vessel subject to defined pressure/temperature transients. A version of the code, revised by Pacific Northwest Laboratory for the US Nuclear Regulatory Commission, was used to evaluate the sensitivities of calculated through-wall flaw probability to material, flaw and calculational assumptions. Probabilities were more sensitive to flaw assumptions than to material or calculational assumptions. Alternative flaw assumptions changed the probabilities by one to two orders of magnitude, whereas alternative material assumptions typically changed the probabilities by a factor of two or less.more » Flaw shape, flaw through-wall position and flaw inspection were sensitivities examined. Material property sensitivities included the assumed distributions in copper content and fracture toughness. Methods of modeling flaw propagation that were evaluated included arrest/reinitiation toughness correlations, multiple toughness values along the length of a flaw, flaw jump distance for each computer simulation and added error in estimating irradiated properties caused by the trend curve correlation error.« less

  4. Sputum Inflammatory Mediators Are Increased in Aspergillus fumigatus Culture-Positive Asthmatics

    PubMed Central

    Ghebre, Michael A; Desai, Dhananjay; Singapuri, Amisha; Woods, Joanne; Rapley, Laura; Cohen, Suzanne; Herath, Athula; Wardlaw, Andrew J; Pashley, Catherine H; May, Richard

    2017-01-01

    Aspergillus fumigatus sensitization and culture in asthma are associated with disease severity and lung function impairment, but their relationship with airway inflammation is poorly understood. We investigated the profile of 24 sputum inflammatory mediators in A. fumigatus culture-positive or-negative moderate-to-severe asthmatics. Fifty-two subjects were recruited from a single center. A. fumigatus was cultured from 19 asthmatics. Asthma control, symptom score, lung function, and sputum cell count were not significantly different between the asthmatics with and without a positive A. fumigatus culture. All of the sputum mediators were numerically increased in subjects with a positive versus negative sputum A. fumigatus culture. Sputum TNF-R2 was significantly elevated (P=0.03) and the mediator that best distinguished A. fumigatus culture-positive from culture-negative subjects (receiver-operator characteristic area under the curve 0.66 [95% CI: 0.51 to 0.82, P=0.045]). A. fumigates-positive culture in moderate-to-severe asthma is associated with increased inflammatory sputum mediators. PMID:28102063

  5. Scoliosis elasticity assessed by manual traction: 49 juvenile and adolescent idiopathic cases.

    PubMed

    Soucacos, P K; Soucacos, P N; Beris, A E

    1996-04-01

    We assessed preoperative curve elasticity in 49 consecutive patients with juvenile or adolescent idiopathic scoliosis who were operated on with Harrington distraction rods. Preoperatively, the curve was determined from posteroanterior radiographs taken in the standing position and in the supine position, with traction. In the latter, the radiographs were taken at the moment of maximal traction when one technician applied traction to the ankles and another to the wrists. The scoliotic curve in the 10 patients with juvenile scoliosis averaged 59 degrees and 32 degrees in the standing and supine positions with traction, respectively. Immediately postoperatively, the curve averaged 19 degrees. 39 patients with adolescent scoliosis had a scoliotic curve which averaged 58 degrees in the standing position and 32 degrees in the supine position with traction. The mean postoperative measurement was 21 degrees. These findings suggest that manual traction is a simple and reliable means of predicting the minimal correction of the scoliotic curve to be expected, using Harrington distraction rods.

  6. Evaluation of Echocardiographic Epicardial Fat Thickness as a Sign of Cardiovascular Risk in Positive Exercise Test Patients.

    PubMed

    Katlandur, Hüseyin; Ulucan, Şeref; Özdil, Hüseyin; Keser, Ahmet; Kaya, Zeynettin; Özbek, Kerem; Ülgen, M Sıddık

    2016-11-01

    The association between epicardial fat thickness (EFT) and positive exercise test results for the diagnosis of coronary artery diseases (CAD) has yet to be evaluated. This study assessed the predictive value of EFT for CAD on the angiographs of patients with positive exercise tests. A total of 91 subjects were chosen consecutively from stable angina pectoris patients who were referred for coronary angiography due to a positive exercise test result. The EFT measures were obtained by echocardiographic parasternal long-axis views on the free wall of the right ventricle at end-systole of three cardiac cycles. Gensini scores were calculated by a conventional coronary angiography technique using a calculation method previously defined. Receiver operator characteristic (ROC) curve analysis revealed a 0.65 cm (95% confidence interval: 0.628, 0.832, p < 0.001) area under the curve with 74.3% sensitivity and 62.3% specificity at the cut-off value of EFT for the prediction of critical coronary artery stenosis. Following ROC curve analysis, two groups were defined according to EFT cut-off value (groups 1 and 2). The severe coronary stenosis ratio was significantly higher in group 2 compared to group 1 (31.9 % vs. 11%, p < 0.001) and Gensini scores were significantly higher in group 2 (6.3 ± 13.3 vs. 16.5 ± 17.9; p < 0.001). There was no significant correlation between Gensini scores and EFT in group 1 (r = 0.093, p = 0.549), but there was a strong significant correlation in group 2 (r = 0.730, p < 0.001). Linear multivariate regression analysis revealed that EFT (> 0.65 cm) was the only independent risk factor for critical coronary artery stenosis (β = 0.451, p < 0.001). EFT was significantly correlated with the severity and prevalence of coronary artery disease in positive exercise test patients.

  7. Decision curve analysis as a framework to estimate the potential value of screening or other decision-making aids.

    PubMed

    Martin, Michael S; Wells, George A; Crocker, Anne G; Potter, Beth K; Colman, Ian

    2018-03-01

    There is an increasing debate about the impact of mental health screening. We illustrate the use of a decision making framework that can be applied when there is no sufficient data to support a traditional cost-benefit analysis. We conducted secondary analyses of data from 459 male prisoners who were screened upon intake. We compared the potential benefit of different approaches (screening, history taking, and universal interventions) to allocating treatment resources using decision curve analysis. Screening prisoners for distress at typical levels of sensitivity (75%) and specificity (71%) were estimated to provide the greatest net benefit if between 2 and 5 false positives per detected illness are tolerable. History taking and self-harm screening provide the largest net benefit when only 1 or 2 false positives per detected illness would be tolerable. The benefits of screening were less among those without a recent psychiatric history, ethnic minorities, and those with fewer psychosocial needs. Although screening has potential to increase detection of treatment, important subgroup differences exist. Greater consideration of responses to positive screens or alternatives to screening are needed to maximize the impact of efforts to improve detection and treatment of mental illness. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Diagnostic Accuracy of 64Copper Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Primary Lymph Node Staging of Intermediate- to High-risk Prostate Cancer: Our Preliminary Experience.

    PubMed

    Cantiello, Francesco; Gangemi, Vincenzo; Cascini, Giuseppe Lucio; Calabria, Ferdinando; Moschini, Marco; Ferro, Matteo; Musi, Gennaro; Butticè, Salvatore; Salonia, Andrea; Briganti, Alberto; Damiano, Rocco

    2017-08-01

    To assess the diagnostic accuracy of 64 Copper prostate-specific membrane antigen ( 64 Cu-PSMA) positron emission tomography/computed tomography (PET/CT) in the primary lymph node (LN) staging of a selected cohort of intermediate- to high-risk prostate cancer (PCa) patients. An observational prospective study was performed in 23 patients with intermediate- to high-risk PCa, who underwent 64 Cu-PSMA PET/CT for local and lymph nodal staging before laparoscopic radical prostatectomy with an extended pelvic LN dissection. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for LN status of 64 Cu-PSMA PET/CT were calculated using the final pathological findings as reference. Furthermore, we evaluated the correlation of intraprostatic tumor extent and grading with 64 Cu-PSMA intraprostatic distribution. Pathological analysis of LN involvement in 413 LNs harvested from our study cohort identified a total of 22 LN metastases in 8 (5%) of the 23 (35%) PCa patients. Imaging-based LN staging in a per-patient analysis showed that 64 Cu-PSMA PET/CT was positive in 7 of 8 LN-positive patients (22%) with a sensitivity of 87.5%, specificity of 100%, PPV of 100%, and NPV of 93.7%, considering the maximum standardized uptake value (SUV max ) at 4 hours as our reference. Receiver operating characteristic curve was characterized by an area under the curve of 0.938. A significant positive association was observed between SUV max at 4 hours with Gleason score, index, and cumulative tumor volume. In our intermediate- to high-risk PCa patients study cohort, we showed the high diagnostic accuracy of 64 Cu-PSMA PET/CT for primary LN staging before radical prostatectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The Total Urine Protein-to-Creatinine Ratio Can Predict the Presence of Microalbuminuria

    PubMed Central

    Yamamoto, Kyoko; Yamamoto, Hiroyuki; Yoshida, Katsumi; Niwa, Koichiro; Nishi, Yutaro; Mizuno, Atsushi; Kuwabara, Masanari; Asano, Taku; Sakoda, Kunihiro; Niinuma, Hiroyuki; Nakahara, Fumiko; Takeda, Kyoko; Shindoh, Chiyohiko; Komatsu, Yasuhiro

    2014-01-01

    Background The Kidney Disease: Improving Global Outcomes chronic kidney disease (CKD) guidelines recommend that CKD be classified based on the etiology, glomerular filtration rate (GFR) and degree of albuminuria. The present study aimed to establish a method that predicts the presence of microalbuminuria by measuring the total urine protein-to-creatinine ratio (TPCR) in patients with cardiovascular disease (CVD) risk factors. Methods and Results We obtained urine samples from 1,033 patients who visited the cardiovascular clinic at St. Luke's International Hospital from February 2012 to August 2012. We measured the TPCR and the urine albumin-to-creatinine ratio (ACR) from random spot urine samples. We performed correlation, receiver operating characteristic (ROC) curve, sensitivity, and subgroup analyses. There was a strong positive correlation between the TPCR and ACR (R2 = 0.861, p<0.001). A ROC curve analysis for the TPCR revealed a sensitivity of 94.4%, a specificity of 86.1%, and an area under the curve of 0.903 for detecting microalbuminuria for a TPCR cut-off value of 84 mg/g of creatinine. The subgroup analysis indicated that the cut-off value could be used for patients with CVD risk factors. Conclusions These results suggest that the TPCR with an appropriate cut-off value could be used to screen for the presence of microalbuminuria in patients with CVD risk factors. This simple, inexpensive measurement has broader applications, leading to earlier intervention and public benefit. PMID:24614247

  10. A comparison of PCR assays for beak and feather disease virus and high resolution melt (HRM) curve analysis of replicase associated protein and capsid genes.

    PubMed

    Das, Shubhagata; Sarker, Subir; Ghorashi, Seyed Ali; Forwood, Jade K; Raidal, Shane R

    2016-11-01

    Beak and feather disease virus (BFDV) threatens a wide range of endangered psittacine birds worldwide. In this study, we assessed a novel PCR assay and genetic screening method using high-resolution melt (HRM) curve analysis for BFDV targeting the capsid (Cap) gene (HRM-Cap) alongside conventional PCR detection as well as a PCR method that targets a much smaller fragment of the virus genome in the replicase initiator protein (Rep) gene (HRM-Rep). Limits of detection, sensitivity, specificity and discriminatory power for differentiating BFDV sequences were compared. HRM-Cap had a high positive predictive value and could readily differentiate between a reference genotype and 17 other diverse BFDV genomes with more discriminatory power (genotype confidence percentage) than HRM-Rep. Melt curve profiles generated by HRM-Cap correlated with unique DNA sequence profiles for each individual test genome. The limit of detection of HRM-Cap was lower (2×10 -5 ng/reaction or 48 viral copies) than that for both HRM-Rep and conventional BFDV PCR which had similar sensitivity (2×10 -6 ng or 13 viral copies/reaction). However, when used in a diagnostic setting with 348 clinical samples there was strong agreement between HRM-Cap and conventional PCR (kappa=0.87, P<0.01, 98% specificity) and HRM-Cap demonstrated higher specificity (99.9%) than HRM-Rep (80.3%). Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Validation of the Patient Health Questionnaire-9 (PHQ-9) For Depression Screening in Adults with Epilepsy

    PubMed Central

    Rathore, Jaivir S.; Jehi, Lara E.; Fan, Youran; Patel, Sima I.; Foldvary-Schaefer, Nancy; Ramirez, Maya J.; Busch, Robyn M.; Obuchowski, Nancy A.; Tesar, George E.

    2015-01-01

    Objective Assess accuracy and operating characteristics of the Patient Health Questionnaire-9 (PHQ-9) for depression-screening in adults with epilepsy. Methods Tertiary epilepsy center patients served as the study population with 237 agreeing to structured interview using the Mini-International Neuropsychiatric Interview (MINI), a “gold standard” instrument developed for rapid diagnosis of neuropsychiatric disorders, including major depressive disorder (MDD); 172 also completed the PHQ-9, and 127 completed both the PHQ-9 and the Neurological Disorders Depression Inventory for Epilepsy (NDDI-E) within two days of the MINI. Sensitivity, specificity, positive & negative predictive values & areas under the ROC curves for each instrument were determined. Cut-points of 10 for the PHQ-9 and 15 for the NDDI-E were used and ratings at or above the cut-points were considered screen-positive. The PHQ-9 was divided into cognitive/affective (PHQ-9/CA) and somatic (PHQ-9/S) subscales to determine comparative depression-screening accuracy. Results The calculated areas under the ROC curves for the PHQ-9 (n=172) and the PHQ-9/CA and PHQ-9/S sub-scales were 0.914, 0.924, and 0.846, respectively, with the PHQ-9 more accurate than the PHQ-9/S (p=0.002) but no different than the PHQ-9/CA (p=0.378). At cut-points of 10 and 15, respectively, the PHQ-9 had higher sensitivity (0.92 vs 0.87), but lower specificity (0.74 vs 0.89) than the NDDI-E. The areas under the ROC curves of the PHQ-9 and the NDDI-E showed similar accuracy (n=127; 0.930 vs 0.934; p=0.864). Significance The PHQ-9 is an efficient & non-proprietary depression screening instrument with excellent accuracy validated for use in adult epilepsy patients as well as multiple other medical populations. PMID:25064739

  12. Fecal immunochemical test for predicting mucosal healing in ulcerative colitis patients: A systematic review and meta-analysis.

    PubMed

    Dai, Cong; Jiang, Min; Sun, Ming-Jun; Cao, Qin

    2018-05-01

    Fecal immunochemical test (FIT) is a promising marker for assessment of inflammatory bowel disease activity. However, the utility of FIT for predicting mucosal healing (MH) of ulcerative colitis (UC) patients has yet to be clearly demonstrated. The objective of our study was to perform a diagnostic test accuracy test meta-analysis evaluating the diagnostic accuracy of FIT in predicting MH of UC patients. We systematically searched the databases from inception to November 2017 that evaluated MH in UC. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Six studies comprising 625 UC patients were included in the meta-analysis. The pooled sensitivity and specificity values for predicting MH in UC were 0.77 (95% confidence interval [CI], 0.72-0.81) and 0.81 (95% CI, 0.76-0.85), respectively. The FIT level had a high rule-in value (positive likelihood ratio, 3.79; 95% CI, 2.85-5.03) and a moderate rule-out value (negative likelihood ratio, 0.26; 95% CI, 0.16-0.43) for predicting MH in UC. The results of the receiver operating characteristic curve analysis (area under the curve, 0.88; standard error of the mean, 0.02) and diagnostic odds ratio (18.08; 95% CI, 9.57-34.13) also revealed improved discrimination for identifying MH in UC with FIT concentration. Our meta-analysis has found that FIT is a simple, reliable non-invasive marker for predicting MH in UC patients. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  13. Reliability and validity of the PHQ-9 for screening late-life depression in Chinese primary care.

    PubMed

    Chen, Shulin; Chiu, Helen; Xu, Baihua; Ma, Yan; Jin, Tao; Wu, Manhua; Conwell, Yeates

    2010-11-01

    The aim of this study was to examine the reliability and validation of the 9-item Patient Health Questionnaire (PHQ-9) for late-life depression in Chinese primary care. In the primary care clinics (PCCs) of Hangzhou city, we recruited 364 older patients (aged ≥ 60) for the PHQ-9 screening. Then 77 of them were further interviewed with Structured Clinical Interview for DSM Disorders (SCID) for the diagnosis of major depression in late life. Statistic strategies for the feasibility, reliability, validity, and receiver operating characteristic curve were performed. The mean administration time was 7.5 min, and the Cronbach's α was 0.91. The optimal cut-off score of PHQ-9 ≥ 9 revealed a sensitivity of 0.86, specificity of 0.77, and positive likelihood ratio of 5.73. The area under the curve (AUC) in this study was 0.92 (SD = 0.02, 95% CI 0.88-0.96). The PHQ-2 also revealed good sensitivity (0.84) and specificity (0.90) at the cut-off point ≥ 3. The PHQ-9 performs well and has acceptable psychometric properties for screening of patients with late-life depression in Chinese primary care settings.

  14. Evaluation of Four Diagnostic Tests for Insulin Dysregulation in Adult Light-Breed Horses.

    PubMed

    Dunbar, L K; Mielnicki, K A; Dembek, K A; Toribio, R E; Burns, T A

    2016-05-01

    Several tests have been evaluated in horses for quantifying insulin dysregulation to support a diagnosis of equine metabolic syndrome. Comparing the performance of these tests in the same horses will provide clarification of their accuracy in the diagnosis of equine insulin dysregulation. The aim of this study was to evaluate the agreement between basal serum insulin concentrations (BIC), the oral sugar test (OST), the combined glucose-insulin test (CGIT), and the frequently sampled insulin-modified intravenous glucose tolerance test (FSIGTT). Twelve healthy, light-breed horses. Randomized, prospective study. Each of the above tests was performed on 12 horses. Minimal model analysis of the FSIGTT was considered the reference standard and classified 7 horses as insulin resistant (IR) and 5 as insulin sensitive (IS). In contrast, BIC and OST assessment using conventional cut-off values classified all horses as IS. Kappa coefficients, measuring agreement among BIC, OST, CGIT, and FSIGTT were poor to fair. Sensitivity of the CGIT (positive phase duration of the glucose curve >45 minutes) was 85.7% and specificity was 40%, whereas CGIT ([insulin]45 >100 μIU/mL) sensitivity and specificity were 28.5% and 100%, respectively. Area under the glucose curve (AUCg0-120 ) was significantly correlated among the OST, CGIT, and FSIGTT, but Bland-Altman method and Lin's concordance coefficient showed a lack of agreement. Current criteria for diagnosis of insulin resistance using BIC and the OST are highly specific but lack sensitivity. The CGIT displayed better sensitivity and specificity, but modifications may be necessary to improve agreement with minimal model analysis. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  15. Role of the Egami score to predict immunoglobulin resistance in Kawasaki disease among a Western Mediterranean population.

    PubMed

    Sánchez-Manubens, Judith; Antón, Jordi; Bou, Rosa; Iglesias, Estíbaliz; Calzada-Hernandez, Joan; Borlan, Sergi; Gimenez-Roca, Clara; Rivera, Josefa

    2016-07-01

    Kawasaki disease is an acute self-limited systemic vasculitis common in childhood. Intravenous immunoglobulin (IVIG) is an effective treatment, and it reduces the incidence of cardiac complications. Egami score has been validated to identify IVIG non-responder patients in Japanese population, and it has shown high sensitivity and specificity to identify these non-responder patients. Although its effectiveness in Japan, Egami score has shown to be ineffective in non-Japanese populations. The aim of this study was to apply the Egami score in a Western Mediterranean population in Catalonia (Spain). Observational population-based study that includes patients from all Pediatric Units in 33 Catalan hospitals, both public and private management, between January 2004 and March 2014. Sensitivity and specificity for the Egami score was calculated, and a logistic regression analysis of predictors of overall response to IVIG was also developed. Predicting IVIG resistance with a cutoff for Egami score ≥3 obtained 26 % sensitivity and 82 % specificity. Negative predictive value was 85 % and positive predictive value 22 %. This low sensitivity implies that three out of four non-responders will not be identified by the Egami score. Besides, logistic regression models did not found significance for the use of the Egami score to predict IVIG resistance in Catalan population although having an area under the ROC curve of 0.618 (IC 95 % 0.538-0.698, p < 0.001). Although regression models found an area under the ROC curve >0.5 to predict IVIG resistance, the low sensitivity excludes the Egami score as a useful tool to predict IVIG resistance in Catalan population.

  16. O-5S quantitative real-time PCR: a new diagnostic tool for laboratory confirmation of human onchocerciasis.

    PubMed

    Mekonnen, Solomon A; Beissner, Marcus; Saar, Malkin; Ali, Solomon; Zeynudin, Ahmed; Tesfaye, Kassahun; Adbaru, Mulatu G; Battke, Florian; Poppert, Sven; Hoelscher, Michael; Löscher, Thomas; Bretzel, Gisela; Herbinger, Karl-Heinz

    2017-10-02

    Onchocerciasis is a parasitic disease caused by the filarial nematode Onchocerca volvulus. In endemic areas, the diagnosis is commonly confirmed by microscopic examination of skin snip samples, though this technique is considered to have low sensitivity. The available melting-curve based quantitative real-time PCR (qPCR) using degenerated primers targeting the O-150 repeat of O. volvulus was considered insufficient for confirming the individual diagnosis, especially in elimination studies. This study aimed to improve detection of O. volvulus DNA in clinical samples through the development of a highly sensitive qPCR assay. A novel hydrolysis probe based qPCR assay was designed targeting the specific sequence of the O. volvulus O-5S rRNA gene. A total of 200 clinically suspected onchocerciasis cases were included from Goma district in South-west Ethiopia, from October 2012 through May 2013. Skin snip samples were collected and subjected to microscopy, O-150 qPCR, and the novel O-5S qPCR. Among the 200 individuals, 133 patients tested positive (positivity rate of 66.5%) and 67 negative by O-5S qPCR, 74 tested positive by microscopy (37.0%) and 78 tested positive by O-150 qPCR (39.0%). Among the 133 O-5S qPCR positive individuals, microscopy and O-150 qPCR detected 55.6 and 59.4% patients, respectively, implying a higher sensitivity of O-5S qPCR than microscopy and O-150 qPCR. None of the 67 individuals who tested negative by O-5S qPCR tested positive by microscopy or O-150 qPCR, implying 100% specificity of the newly designed O-5S qPCR assay. The novel O-5S qPCR assay is more sensitive than both microscopic examination and the existing O-150 qPCR for the detection of O. volvulus from skin snip samples. The newly designed assay is an important step towards appropriate individual diagnosis and control of onchocerciasis.

  17. Prediction of Fetal Growth Restriction by Analyzing the Messenger RNAs of Angiogenic Factor in the Plasma of Pregnant Women.

    PubMed

    Takenaka, Shin; Ventura, Walter; Sterrantino, Anna Freni; Kawashima, Akihiro; Koide, Keiko; Hori, Kyoko; Farina, Antonio; Sekizawa, Akihiko

    2015-06-01

    To predict the occurrence of fetal growth restriction (FGR) by analyzing messenger RNA (mRNA) expression levels of vascular endothelial growth factor receptor 1 (fms-like tyrosine kinase 1 [Flt-1]) in maternal blood. Eleven women with FGR were matched with 88 controls. Plasma samples were obtained during each trimester. The Flt-1 mRNA expression levels were compared between groups. Predicted probabilities were calculated, and sensitivity-specificity (receiver-operating characteristic [ROC]) curves were assessed based on regression models for each trimester measurement and possible combinations of measurements. The mRNA levels of the FGR group during all trimesters were significantly higher than those of the control group. The ROC curve of combined first and second trimester data yielded a detection rate of 60% at a 10% false-positive rate, with an area under curve of 0.79. The Flt-1 mRNA expression in maternal blood can be used as a marker to predict the development of FGR, long before a clinical diagnosis is made. © The Author(s) 2014.

  18. LGALS4, CEACAM6, TSPAN8, and COL1A2: Blood Markers for Colorectal Cancer-Validation in a Cohort of Subjects With Positive Fecal Immunochemical Test Result.

    PubMed

    Rodia, Maria Teresa; Solmi, Rossella; Pasini, Francesco; Nardi, Elena; Mattei, Gabriella; Ugolini, Giampaolo; Ricciardiello, Luigi; Strippoli, Pierluigi; Miglio, Rossella; Lauriola, Mattia

    2018-06-01

    A noninvasive blood test for the early detection of colorectal cancer (CRC) is highly required. We evaluated a panel of 4 mRNAs as putative markers of CRC. We tested LGALS4, CEACAM6, TSPAN8, and COL1A2, referred to as the CELTiC panel, using quantitative reverse transcription polymerase chain reaction, on subjects with positive fecal immunochemical test (FIT) results and undergoing colonoscopy. Using a nonparametric test and multinomial logistic model, FIT-positive subjects were compared with CRC patients and healthy individuals. All the genes of the CELTiC panel displayed statistically significant differences between the healthy subjects (n = 67), both low-risk (n = 36) and high-risk/CRC (n = 92) subjects, and those in the negative-colonoscopy, FIT-positive group (n = 36). The multinomial logistic model revealed LGALS4 was the most powerful marker discriminating the 4 groups. When assessing the diagnostic values by analysis of the areas under the receiver operating characteristic curves (AUCs), the CELTiC panel reached an AUC of 0.91 (sensitivity, 79%; specificity, 94%) comparing normal subjects to low-risk subjects, and 0.88 (sensitivity, 75%; specificity, 87%) comparing normal and high-risk/CRC subjects. The comparison between the normal subjects and the negative-colonoscopy, FIT-positive group revealed an AUC of 0.93 (sensitivity, 82%; specificity, 97%). The CELTiC panel could represent a useful tool for discriminating subjects with positive FIT findings and for the early detection of precancerous adenomatous lesions and CRC. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Diagnostic value of cerebrospinal fluid Aβ ratios in preclinical Alzheimer's disease.

    PubMed

    Adamczuk, Katarzyna; Schaeverbeke, Jolien; Vanderstichele, Hugo M J; Lilja, Johan; Nelissen, Natalie; Van Laere, Koen; Dupont, Patrick; Hilven, Kelly; Poesen, Koen; Vandenberghe, Rik

    2015-12-18

    In this study of preclinical Alzheimer's disease (AD) we assessed the added diagnostic value of using cerebrospinal fluid (CSF) Aβ ratios rather than Aβ42 in isolation for detecting individuals who are positive on amyloid positron emission tomography (PET). Thirty-eight community-recruited cognitively intact older adults (mean age 73, range 65-80 years) underwent (18)F-flutemetamol PET and CSF measurement of Aβ1-42, Aβ1-40, Aβ1-38, and total tau (ttau). (18)F-flutemetamol retention was quantified using standardized uptake value ratios in a composite cortical region (SUVRcomp) with reference to cerebellar grey matter. Based on a prior autopsy validation study, the SUVRcomp cut-off was 1.57. Sensitivities, specificities and cut-offs were defined based on receiver operating characteristic analysis with CSF analytes as variables of interest and (18)F-flutemetamol positivity as the classifier. We also determined sensitivities and CSF cut-off values at fixed specificities of 90 % and 95 %. Seven out of 38 subjects (18 %) were positive on amyloid PET. Aβ42/ttau, Aβ42/Aβ40, Aβ42/Aβ38, and Aβ42 had the highest accuracy to identify amyloid-positive subjects (area under the curve (AUC) ≥ 0.908). Aβ40 and Aβ38 had significantly lower discriminative power (AUC = 0.571). When specificity was fixed at 90 % and 95 %, Aβ42/ttau had the highest sensitivity among the different CSF markers (85.71 % and 71.43 %, respectively). Sensitivity of Aβ42 alone was significantly lower under these conditions (57.14 % and 42.86 %, respectively). For the CSF-based definition of preclinical AD, if a high specificity is required, our data support the use of Aβ42/ttau rather than using Aβ42 in isolation.

  20. Correlation of skin test results and specific immunoglobulin E blood levels with nasal provocation testing for house-dust mite allergies.

    PubMed

    Haxel, Boris R; Huppertz, Tilman; Boessert, Patrick; Bast, Florian; Fruth, Kai

    2016-01-01

    Allergen-specific immunotherapy for house-dust mite (HDM) allergies is associated with lower success rates when compared with similar treatments for other inhalant allergens, such as grass or birch. One reason might be the greater difficulty in diagnosing patients with assumed HDM allergies because symptoms occur perennially and may differ from those of a conventional allergic rhinitis. The aim of the study was to compare the different methods of diagnosis in patients with assumed HDM allergy. We performed a retrospective analysis of nasal provocation tests (NPT) from patients (n = 161) evaluated for Dermatophagoides pteronyssinus (n = 127) and Dermatophagoides farinae (n = 104) allergies, and compared the results with other allergen testing methods (skin-prick test [SPT], intracutaneous test, and allergen specific immunoglobulin E levels [sIgE] to detect sensitization). Receiver operating characteristic curves were used for the analyses and the areas under the curve were calculated. For D. pteronyssinus and D. farinae, 86 and 70 complete data files, respectively, were available. For both tested HDMs, the results of the receiver operating characteristic curves showed a significant correlation for SPT and sIgE, with the results of the NPT (area under the curve, 0.742 to 0.763) but not for the intracutaneous test. In patients with a positive SPT (≥3 mm), an allergy was confirmed by the NPT in 69% of cases for D. pteronyssinus and 71% for D. farinae. A positive sIgE result (ImmunoCAP class of ≥2) was verified by the NPT in 69% of cases (D. pteronyssinus) and 70% (D. farinae). The predictability value for a positive NPT result is best for SPT and sIgE. Nevertheless, even if the results of both test systems are combined, the positive predictive value that was achieved was only 0.77 for D. pteronyssinus and 0.69 for D. farinae. Therefore, in patients eligible for immunotherapy for HDM, an NPT should be performed before the start of the therapy to verify a clinically relevant allergy.

  1. DECIPHERING THERMAL PHASE CURVES OF DRY, TIDALLY LOCKED TERRESTRIAL PLANETS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koll, Daniel D. B.; Abbot, Dorian S., E-mail: dkoll@uchicago.edu

    2015-03-20

    Next-generation space telescopes will allow us to characterize terrestrial exoplanets. To do so effectively it will be crucial to make use of all available data. We investigate which atmospheric properties can, and cannot, be inferred from the broadband thermal phase curve of a dry and tidally locked terrestrial planet. First, we use dimensional analysis to show that phase curves are controlled by six nondimensional parameters. Second, we use an idealized general circulation model to explore the relative sensitivity of phase curves to these parameters. We find that the feature of phase curves most sensitive to atmospheric parameters is the peak-to-troughmore » amplitude. Moreover, except for hot and rapidly rotating planets, the phase amplitude is primarily sensitive to only two nondimensional parameters: (1) the ratio of dynamical to radiative timescales and (2) the longwave optical depth at the surface. As an application of this technique, we show how phase curve measurements can be combined with transit or emission spectroscopy to yield a new constraint for the surface pressure and atmospheric mass of terrestrial planets. We estimate that a single broadband phase curve, measured over half an orbit with the James Webb Space Telescope, could meaningfully constrain the atmospheric mass of a nearby super-Earth. Such constraints will be important for studying the atmospheric evolution of terrestrial exoplanets as well as characterizing the surface conditions on potentially habitable planets.« less

  2. Screening for HIV-related PTSD: sensitivity and specificity of the 17-item Posttraumatic Stress Diagnostic Scale (PDS) in identifying HIV-related PTSD among a South African sample.

    PubMed

    Martin, L; Fincham, D; Kagee, A

    2009-11-01

    The identification of HIV-positive patients who exhibit criteria for Posttraumatic Stress Disorder (PTSD) and related trauma symptomatology is of clinical importance in the maintenance of their overall wellbeing. This study assessed the sensitivity and specificity of the 17-item Posttraumatic Stress Diagnostic Scale (PDS), a self-report instrument, in the detection of HIV-related PTSD. An adapted version of the PTSD module of the Composite International Diagnostic Interview (CIDI) served as the gold standard. 85 HIV-positive patients diagnosed with HIV within the year preceding data collection were recruited by means of convenience sampling from three HIV clinics within primary health care facilities in the Boland region of South Africa. A significant association was found between the 17-item PDS and the adapted PTSD module of the CIDI. A ROC curve analysis indicated that the 17-item PDS correctly discriminated between PTSD caseness and non-caseness 74.9% of the time. Moreover, a PDS cut-off point of > or = 15 yielded adequate sensitivity (68%) and 1-specificity (65%). The 17-item PDS demonstrated a PPV of 76.0% and a NPV of 56.7%. The 17-item PDS can be used as a brief screening measure for the detection of HIV-related PTSD among HIV-positive patients in South Africa.

  3. Peripheral absolute threshold spectral sensitivity in retinitis pigmentosa.

    PubMed Central

    Massof, R W; Johnson, M A; Finkelstein, D

    1981-01-01

    Dark-adapted spectral sensitivities were measured in the peripheral retinas of 38 patients diagnosed as having typical retinitis pigmentosa (RP) and in 3 normal volunteers. The patients included those having autosomal dominant and autosomal recessive inheritance patterns. Results were analysed by comparisons with the CIE standard scotopic spectral visibility function and with Judd's modification of the photopic spectral visibility function, with consideration of contributions from changes in spectral transmission of preretinal media. The data show 3 general patterns. One group of patients had absolute threshold spectral sensitivities that were fit by Judd's photopic visibility curve. Absolute threshold spectral sensitivities for a second group of patients were fit by a normal scotopic spectral visibility curve. The third group of patients had absolute threshold spectral sensitivities that were fit by a combination of scotopic and photopic spectral visibility curves. The autosomal dominant and autosomal recessive modes of inheritance were represented in each group of patients. These data indicate that RP patients have normal rod and/or cone spectral sensitivities, and support the subclassification of patients described previously by Massof and Finkelstein. PMID:7459312

  4. Exploration of Analysis Methods for Diagnostic Imaging Tests: Problems with ROC AUC and Confidence Scores in CT Colonography

    PubMed Central

    Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.

    2014-01-01

    Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643

  5. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    PubMed

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  6. Heart-type fatty acid binding protein is a sensitive biomarker for early AMI detection in troponin negative patients: a pilot study.

    PubMed

    Agnello, Luisa; Bivona, Giulia; Novo, Giuseppina; Scazzone, Concetta; Muratore, Roberto; Levantino, Piero; Bellia, Chiara; Lo Sasso, Bruna; Ciaccio, Marcello

    2017-10-01

    Early detecting AMI in individuals presenting to the ED with chest pain continues to be a challenge. cTn is the gold standard for AMI diagnosis but early presenters (<1 hours from symptom onset) maybe cTn negative on admission. We analysed the diagnostic value of h-FABP and hs-TnI in patients presenting to ED with chest pain and no cTnI elevations. 28 AMI and 28 no-AMI individuals both presented to ED within one hour from pain onset were included. Blood donors were analysed for h-FABP cut-off identification. Among AMI patients, 55% were positive for h-FABP and 34.6% were positive for hs-TnI (p = .015), thus 21% were positive only for h-FABP. The diagnostic accuracy was assessed by ROC curve. h-FABP showed a higher sensitivity but lower specificity than hs-TnI. In our study, the frequency of h-FABP positivity among AMI patients was higher than that of hs-TnI, which would have missed six of them; however, hs-TnI AUC was superior to that of h-FABP. These preliminary findings might confirm that h-FABP may be a good candidate for AMI rule-in/rule-out within the ED context.

  7. Determining the Sensitivity of CAT-ASVAB (Computerized Adaptive Testing- Armed Services Vocational Aptitude Battery) Scores to Changes in Item Response Curves with the Medium of Administration

    DTIC Science & Technology

    1986-08-01

    most examinees. Therefore it appears psychometrically ac - ceptable for the CAT -ASVAB project to proceed without item recalibration based on...MEMORANDUM DETERMINING THE SENSITIVITY OF CAT -ASVAB SCORES TO CHANGES IN ITEM RESPONSE CURVES WITH THE MEDIUM OF ADMINISTRATION D. R. Divgi...Subj: Center for Naval Analyses Research Memorandum 86-189 End: (1) CNA Research Memorandum 86-189, "Determining the Sensitivity of CAT -ASVAB

  8. Validation of the diagnostic score for acute lower abdominal pain in women of reproductive age.

    PubMed

    Jearwattanakanok, Kijja; Yamada, Sirikan; Suntornlimsiri, Watcharin; Smuthtai, Waratsuda; Patumanond, Jayanton

    2014-01-01

    Background. The differential diagnoses of acute appendicitis obstetrics, and gynecological conditions (OB-GYNc) or nonspecific abdominal pain in young adult females with lower abdominal pain are clinically challenging. The present study aimed to validate the recently developed clinical score for the diagnosis of acute lower abdominal pain in female of reproductive age. Method. Medical records of reproductive age women (15-50 years) who were admitted for acute lower abdominal pain were collected. Validation data were obtained from patients admitted during a different period from the development data. Result. There were 302 patients in the validation cohort. For appendicitis, the score had a sensitivity of 91.9%, a specificity of 79.0%, and a positive likelihood ratio of 4.39. The sensitivity, specificity, and positive likelihood ratio in diagnosis of OB-GYNc were 73.0%, 91.6%, and 8.73, respectively. The areas under the receiver operating curves (ROC), the positive likelihood ratios, for appendicitis and OB-GYNc in the validation data were not significantly different from the development data, implying similar performances. Conclusion. The clinical score developed for the diagnosis of acute lower abdominal pain in female of reproductive age may be applied to guide differential diagnoses in these patients.

  9. Artificial neural network study on organ-targeting peptides

    NASA Astrophysics Data System (ADS)

    Jung, Eunkyoung; Kim, Junhyoung; Choi, Seung-Hoon; Kim, Minkyoung; Rhee, Hokyoung; Shin, Jae-Min; Choi, Kihang; Kang, Sang-Kee; Lee, Nam Kyung; Choi, Yun-Jaie; Jung, Dong Hyun

    2010-01-01

    We report a new approach to studying organ targeting of peptides on the basis of peptide sequence information. The positive control data sets consist of organ-targeting peptide sequences identified by the peroral phage-display technique for four organs, and the negative control data are prepared from random sequences. The capacity of our models to make appropriate predictions is validated by statistical indicators including sensitivity, specificity, enrichment curve, and the area under the receiver operating characteristic (ROC) curve (the ROC score). VHSE descriptor produces statistically significant training models and the models with simple neural network architectures show slightly greater predictive power than those with complex ones. The training and test set statistics indicate that our models could discriminate between organ-targeting and random sequences. We anticipate that our models will be applicable to the selection of organ-targeting peptides for generating peptide drugs or peptidomimetics.

  10. Evaluation of basal sex hormone levels for activation of the hypothalamic-pituitary-gonadal axis.

    PubMed

    Ding, Yu; Li, Juan; Yu, Yongguo; Yang, Peirong; Li, Huaiyuan; Shen, Yongnian; Huang, Xiaodong; Liu, Shijian

    2018-03-28

    This study aimed to identify the predictive value of basal sex hormone levels for activation of the hypothalamic-pituitary-gonadal (HPG) axis in girls. Gonadotropin-releasing hormone (GnRH) stimulation tests were performed and evaluated in a total of 1750 girls with development of secondary sex characteristics. Correlation analyses were conducted between basal sex hormones and peak luteinizing hormone (LH) levels ≥5 IU/L during the GnRH stimulation test. Receiver operating characteristic (ROC) curves for basal levels of LH, follicle-stimulating hormone (FSH), LH/FSH, and estradiol (E2) before the GnRH stimulation test were plotted. The area under the curve (AUC) and 95% confidence intervals (CIs) were measured for each curve. The maximum AUC value was observed for basal LH levels (0.77, 95% CI: 0.74-0.79), followed by basal FSH levels (0.73, 95% CI: 0.70-0.75), the basal LH/FSH ratio (0.68, 95% CI: 0.65-0.71), and basal E2 levels (0.61, 95% CI: 0.59-0.64). The appropriate cutoff value of basal LH levels associated with a positive response of the GnRH stimulation test was 0.35 IU/L, with a sensitivity of 63.96% and specificity of 76.3% from the ROC curves when Youden's index showed the maximum value. When 100% of patients had peak LH levels ≥5 IU/L, basal LH values were >2.72 IU/L, but the specificity was only 5.45%. Increased basal LH levels are a significant predictor of a positive response during the GnRH stimulation test for assessing activation of the HPG axis in most girls with early pubertal signs.

  11. Differentiation between microcystin contaminated and uncontaminated fish by determination of unconjugated MCs using an ELISA anti-Adda test based on receiver-operating characteristic curves threshold values: application to Tinca tinca from natural ponds.

    PubMed

    Moreno, Isabel María; Herrador, M Ángeles; Atencio, Loyda; Puerto, María; González, A Gustavo; Cameán, Ana María

    2011-02-01

    The aim of this study was to evaluate whether the enzyme-linked immunosorbent assay (ELISA) anti-Adda technique could be used to monitor free microcystins (MCs) in biological samples from fish naturally exposed to toxic cyanobacteria by using receiver operating characteristic (ROC) curve software to establish an optimal cut-off value for MCs. The cut-off value determined by ROC curve analysis in tench (Tinca tinca) exposed to MCs under laboratory conditions by ROC curve analysis was 5.90-μg MCs/kg tissue dry weight (d.w.) with a sensitivity of 93.3%. This value was applied in fish samples from natural ponds (Extremadura, Spain) in order to asses its potential MCs bioaccumulation by classifying samples as either true positive (TP), false positive (FP), true negative (TN), or false negative (FN). In this work, it has been demonstrated that toxic cyanobacteria, mainly Microcystis aeruginosa, Aphanizomenon issatchenkoi, and Anabaena spiroides, were present in two of these ponds, Barruecos de Abajo (BDown) and Barruecos de Arriba (BUp). The MCs levels were detected in waters from both ponds with an anti-MC-LR ELISA immunoassay and were of similar values (between 3.8-6.5-μg MC-LR equivalent/L in BDown pond and 4.8-6.0-μg MC-LR equivalent/L in BUp). The MCs cut-off values were applied in livers from fish collected from these two ponds using the ELISA anti-Adda technique. A total of 83% of samples from BDown pond and only 42% from BUp were TP with values of free MCs higher than 8.8-μg MCs/kg tissue (d.w.). Copyright © 2009 Wiley Periodicals, Inc.

  12. Can 3'-Deoxy-3'-((18)F) Fluorothymidine Out Perform 2-Deoxy-2-((18)F) Fluoro-D-Glucose Positron Emission Tomography/Computed Tomography in the Diagnosis of Cervical Lymphadenopathy in Patients With Oral/Head and Neck Cancer?

    PubMed

    Schaefferkoetter, Joshua D; Carlson, Eric R; Heidel, Robert E

    2015-07-01

    The present study investigated the performance of cellular metabolism imaging with 2-deoxy-2-((18)F) fluoro-D-glucose (FDG) versus cellular proliferation imaging with 3'-deoxy-3'-((18)F) fluorothymidine (FLT) in the detection of cervical lymph node metastases in oral/head and neck cancer. We conducted a prospective cohort study to assess a head-to-head performance of FLT imaging and clinical FDG imaging for characterizing cervical lymph node metastases in patients with squamous cell carcinoma (SCC) of the oral/head and neck region. The primary predictor variable of the study was the presence of FDG or FLT avidity within the cervical lymph nodes. The primary outcome variable was the histologic presence of metastatic SCC in the cervical lymph nodes. The performance was reported in terms of the sensitivity, specificity, accuracy, and positive and negative predictive values. The overall accuracy for discriminating positive from negative lymph nodes was evaluated as a function of the positron emission tomography (PET) standardized uptake value (SUV). Receiver operating characteristic (ROC) analyses were performed for both tracers. Eleven patients undergoing surgical resection of SCC of the oral/head and neck region underwent preoperative FDG and FLT PET-computed tomography (CT) scans on separate days. The interpretation of the FDG PET-CT imaging resulted in sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 43.2, 99.5, 94.4, 88.9, and 94.7%, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for FLT PET-CT imaging was 75.7, 99.2, 97.1, 90.3, and 97.7%, respectively. The areas under the curve for the ROC curves were 0.9 and 0.84 for FDG and FLT, respectively. Poor correlation was observed between the SUV for FDG and FLT within the lymph nodes and tumors. FLT showed better overall performance for detecting lymphadenopathy on qualitative assessment within the total nodal population. This notwithstanding, FDG SUV performed better for pathologic discrimination within the visible lymph nodes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Positive alcohol use expectancies moderate the association between anxiety sensitivity and alcohol use across adolescence.

    PubMed

    Borges, Allison M; Lejuez, Carl W; Felton, Julia W

    2018-06-01

    Anxiety sensitivity (AS), or the fear of anxious symptoms and the belief that these symptoms may have negative physical, social, and cognitive consequences, is one personality trait that emerges in early adolescence and may be linked to alcohol use. However, findings are equivocal as to whether elevated AS during adolescence directly predicts alcohol use. Adolescents do report increases in positive alcohol use expectancies during this developmental period, and these expectancies have been found to be significantly associated with alcohol use. The current study examined whether positive alcohol use expectancies and AS in early adolescence predicted changes in alcohol use throughout adolescence. This aim was examined via secondary data analyses from a longitudinal study examining the development of risk behaviors in adolescents. Results of univariate latent growth curve modeling suggest that AS alone was not a significant predictor of baseline alcohol use or change in use over time after controlling for gender, age, and self-reported anxiety. However, AS in early adolescence was found to be a significant predictor of increases in alcohol use across adolescence for youth who reported greater positive alcohol use expectancies. These results indicate that beliefs regarding the positive effects of alcohol use are an important moderator in the relation between AS and change in alcohol use during adolescence. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A semiparametric separation curve approach for comparing correlated ROC data from multiple markers

    PubMed Central

    Tang, Liansheng Larry; Zhou, Xiao-Hua

    2012-01-01

    In this article we propose a separation curve method to identify the range of false positive rates for which two ROC curves differ or one ROC curve is superior to the other. Our method is based on a general multivariate ROC curve model, including interaction terms between discrete covariates and false positive rates. It is applicable with most existing ROC curve models. Furthermore, we introduce a semiparametric least squares ROC estimator and apply the estimator to the separation curve method. We derive a sandwich estimator for the covariance matrix of the semiparametric estimator. We illustrate the application of our separation curve method through two real life examples. PMID:23074360

  15. Interstellar extinction curve variations towards the inner Milky Way: a challenge to observational cosmology

    NASA Astrophysics Data System (ADS)

    Nataf, David M.; Gonzalez, Oscar A.; Casagrande, Luca; Zasowski, Gail; Wegg, Christopher; Wolf, Christian; Kunder, Andrea; Alonso-Garcia, Javier; Minniti, Dante; Rejkuba, Marina; Saito, Roberto K.; Valenti, Elena; Zoccali, Manuela; Poleski, Radosław; Pietrzyński, Grzegorz; Skowron, Jan; Soszyński, Igor; Szymański, Michał K.; Udalski, Andrzej; Ulaczyk, Krzysztof; Wyrzykowski, Łukasz

    2016-03-01

    We investigate interstellar extinction curve variations towards ˜4 deg2 of the inner Milky Way in VIJKs photometry from the OGLE-III (third phase of the Optical Gravitational Lensing Experiment) and VVV (VISTA Variables in the Via Lactea) surveys, with supporting evidence from diffuse interstellar bands and F435W, F625W photometry. We obtain independent measurements towards ˜2000 sightlines of AI, E(V - I), E(I - J) and E(J - Ks), with median precision and accuracy of 2 per cent. We find that the variations in the extinction ratios AI/E(V - I), E(I - J)/E(V - I) and E(J - Ks)/E(V - I) are large (exceeding 20 per cent), significant and positively correlated, as expected. However, both the mean values and the trends in these extinction ratios are drastically shifted from the predictions of Cardelli and Fitzpatrick, regardless of how RV is varied. Furthermore, we demonstrate that variations in the shape of the extinction curve have at least two degrees of freedom, and not one (e.g. RV), which we confirm with a principal component analysis. We derive a median value of = 13.44, which is ˜60 per cent higher than the `standard' value. We show that the Wesenheit magnitude WI = I - 1.61(I - J) is relatively impervious to extinction curve variations. Given that these extinction curves are linchpins of observational cosmology, and that it is generally assumed that RV variations correctly capture variations in the extinction curve, we argue that systematic errors in the distance ladder from studies of Type Ia supernovae and Cepheids may have been underestimated. Moreover, the reddening maps from the Planck experiment are shown to systematically overestimate dust extinction by ˜100 per cent and lack sensitivity to extinction curve variations.

  16. Rethinking non-inferiority: a practical trial design for optimising treatment duration.

    PubMed

    Quartagno, Matteo; Walker, A Sarah; Carpenter, James R; Phillips, Patrick Pj; Parmar, Mahesh Kb

    2018-06-01

    Background Trials to identify the minimal effective treatment duration are needed in different therapeutic areas, including bacterial infections, tuberculosis and hepatitis C. However, standard non-inferiority designs have several limitations, including arbitrariness of non-inferiority margins, choice of research arms and very large sample sizes. Methods We recast the problem of finding an appropriate non-inferior treatment duration in terms of modelling the entire duration-response curve within a pre-specified range. We propose a multi-arm randomised trial design, allocating patients to different treatment durations. We use fractional polynomials and spline-based methods to flexibly model the duration-response curve. We call this a 'Durations design'. We compare different methods in terms of a scaled version of the area between true and estimated prediction curves. We evaluate sensitivity to key design parameters, including sample size, number and position of arms. Results A total sample size of ~ 500 patients divided into a moderate number of equidistant arms (5-7) is sufficient to estimate the duration-response curve within a 5% error margin in 95% of the simulations. Fractional polynomials provide similar or better results than spline-based methods in most scenarios. Conclusion Our proposed practical randomised trial 'Durations design' shows promising performance in the estimation of the duration-response curve; subject to a pending careful investigation of its inferential properties, it provides a potential alternative to standard non-inferiority designs, avoiding many of their limitations, and yet being fairly robust to different possible duration-response curves. The trial outcome is the whole duration-response curve, which may be used by clinicians and policymakers to make informed decisions, facilitating a move away from a forced binary hypothesis testing paradigm.

  17. Performance and stability analysis of curcumin dye as a photo sensitizer used in nanostructured ZnO based DSSC

    NASA Astrophysics Data System (ADS)

    Sinha, D.; De, D.; Ayaz, A.

    2018-03-01

    Environmental friendly natural dye curcumin extracted from low-cost Curcumina longa stem is used as a photo-sensitizer for the fabrication of ZnO-based dye-sensitized solar cells (DSSC). Nanostructured ZnO is fabricated on a transparent conducting glass (TCO), using a cost-effective chemical bath deposition technique. Scanning electron microscopic images show hexagonal patterned ZnO nano-towers decorated with several nanosteps. The average length of ZnO nano-tower is 5 μm and diameter is 1.2 μm. The UV-Vis spectroscopic study of the curcumin dye is used to understand the light absorption behavior as well as band gap energy of the extracted natural dye. The dye shows wider absorption band-groups over 350-470 nm and 500-600 nm with two peaks positioned at 425 nm and 525 nm. The optical band gap energy and energy band position of the dye is derived which supports its stability and high electron affinity that makes it suitable for light harvesting and effortless electron transfer from dye to the semiconductor or interface between them. FTIR spectrum of curcumin dye-sensitized ZnO-based DSSC shows the presence of anchoring groups and colouring constitutes. The I-V and P-V curves of the fabricated DSSC are measured under simulated light (100 mW/cm2). The highest visible light to electric conversion efficiency of 0.266% (using ITO) and 0.33% (using FTO) is achieved from the curcumin dye-sensitized cell.

  18. Meta-analysis of diagnostic accuracy studies in mental health

    PubMed Central

    Takwoingi, Yemisi; Riley, Richard D; Deeks, Jonathan J

    2015-01-01

    Objectives To explain methods for data synthesis of evidence from diagnostic test accuracy (DTA) studies, and to illustrate different types of analyses that may be performed in a DTA systematic review. Methods We described properties of meta-analytic methods for quantitative synthesis of evidence. We used a DTA review comparing the accuracy of three screening questionnaires for bipolar disorder to illustrate application of the methods for each type of analysis. Results The discriminatory ability of a test is commonly expressed in terms of sensitivity (proportion of those with the condition who test positive) and specificity (proportion of those without the condition who test negative). There is a trade-off between sensitivity and specificity, as an increasing threshold for defining test positivity will decrease sensitivity and increase specificity. Methods recommended for meta-analysis of DTA studies --such as the bivariate or hierarchical summary receiver operating characteristic (HSROC) model --jointly summarise sensitivity and specificity while taking into account this threshold effect, as well as allowing for between study differences in test performance beyond what would be expected by chance. The bivariate model focuses on estimation of a summary sensitivity and specificity at a common threshold while the HSROC model focuses on the estimation of a summary curve from studies that have used different thresholds. Conclusions Meta-analyses of diagnostic accuracy studies can provide answers to important clinical questions. We hope this article will provide clinicians with sufficient understanding of the terminology and methods to aid interpretation of systematic reviews and facilitate better patient care. PMID:26446042

  19. The Value of Neutrophil to Lymphocyte Ratio and Platelet to Lymphocyte Ratio for Detecting Early-onset Neonatal Sepsis.

    PubMed

    Can, Emrah; Hamilcikan, Şahin; Can, Ceren

    2018-05-01

    The purpose of this study was to investigate the relationship between neonate early-onset sepsis (EOS) and the neutrophil to lymphocyte ratio (NLR) and the platelet to lymphocyte ratio (PLR) of term neonates. This prospective observational study was conducted with term neonates diagnosed with EOS compared with 44 healthy controls. Exclusion criteria were prematurity, postmaturity, small or large for gestational age according to week of pregnancy, preeclampsia, gestational diabetes mellitus, chorioamnionitis, congenital major anomalies, and cyanotic congenital heart disease. A total of 122 term neonates were included in the study. Of these, 78 were diagnosed with EOS and 44 were healthy controls. Tachycardia and apnea with bradycardia were the most common clinical signs of the onset of EOS in neonates in the EOS group. This group had significantly higher neutrophil counts, axillary temperatures, NLRs, PLRs, C-reactive proteins, and procalcitonin levels compared with the control group. There was a positive association between neutrophil counts, NLR, and PLR in the EOS group. An NLR of 6.76 was determined as the predictive cutoff value of neonate EOS (sensitivity 97.4%; specificity 100%; area under the receiver-operating characteristic curve 0.99; P=0.001). A PLR of 94.05 was determined as the predictive cutoff value of neonate EOS (sensitivity 97.4; specificity 100%; area under the receiver-operating characteristic curve 0.93; P=0.001). NLRs and PLRs were positively correlated with EOS in term neonates, and these ratios can be used as diagnostic adjunct tests for neonate EOS workups.

  20. FAST for blunt abdominal trauma: Correlation between positive findings and admission acid-base measurement.

    PubMed

    Heidari, Kamran; Taghizadeh, Mehrdad; Mahmoudi, Sadrollah; Panahi, Hamidreza; Ghaffari Shad, Ensieh; Asadollahi, Shadi

    2017-06-01

    This study aimed to determine any association between positive findings in ultrasonography examination and initial BD value with regard to diagnosis of intra-abdominal bleeding following blunt abdominal trauma. A prospective, multi-center study of consecutive adult patients was performed from April to September 2015. Demographics, initial vital signs and arterial BD were evaluated with respect to presence of any association with intra-abdominal bleeding and in-hospital mortality. FAST study was performed to find intra-abdominal bleeding. Receiver operating characteristic (ROC) curves tested the ability of BD to identify patients with intra-abdominal hemorrhage and probable mortality. A total of 879 patients were included in final analysis. The mean (SD) age was 36.68 (15.7) years and 714 patients (81.2%) were male. According to multivariable analysis, statistically significant association was observed between negative admission BD and both intra-abdominal bleeding (OR 3.48, 95% CI 2.06-5.88, p<0.001) and in-hospital mortality (OR 1.55, 95% CI 1.49-1.63, p<0.001). ROC curve analysis demonstrated sensitivity of 92.7% and specificity of 22.1% for the best cut-off value of BD (-8mEq/L) to diagnose internal hemorrhage. Further, a cut-off value of -7mEq/L demonstrated significant predictive performance, 94.8% sensitivity and 53.6% specificity for in-hospital mortality. This study revealed that arterial BD is an early accessible important marker to identify intra-abdominal bleeding, as well as to predict overall in-hospital mortality in patients with blunt abdominal trauma. Copyright © 2017. Published by Elsevier Inc.

  1. Diagnostic Accuracy of a New Cardiac Electrical Biomarker for Detection of Electrocardiogram Changes Suggestive of Acute Myocardial Ischemic Injury

    PubMed Central

    Schreck, David M; Fishberg, Robert D

    2014-01-01

    Objective A new cardiac “electrical” biomarker (CEB) for detection of 12-lead electrocardiogram (ECG) changes indicative of acute myocardial ischemic injury has been identified. Objective was to test CEB diagnostic accuracy. Methods This is a blinded, observational retrospective case-control, noninferiority study. A total of 508 ECGs obtained from archived digital databases were interpreted by cardiologist and emergency physician (EP) blinded reference standards for presence of acute myocardial ischemic injury. CEB was constructed from three ECG cardiac monitoring leads using nonlinear modeling. Comparative active controls included ST voltage changes (J-point, ST area under curve) and a computerized ECG interpretive algorithm (ECGI). Training set of 141 ECGs identified CEB cutoffs by receiver-operating-characteristic (ROC) analysis. Test set of 367 ECGs was analyzed for validation. Poor-quality ECGs were excluded. Sensitivity, specificity, and negative and positive predictive values were calculated with 95% confidence intervals. Adjudication was performed by consensus. Results CEB demonstrated noninferiority to all active controls by hypothesis testing. CEB adjudication demonstrated 85.3–94.4% sensitivity, 92.5–93.0% specificity, 93.8–98.6% negative predictive value, and 74.6–83.5% positive predictive value. CEB was superior against all active controls in EP analysis, and against ST area under curve and ECGI by cardiologist. Conclusion CEB detects acute myocardial ischemic injury with high diagnostic accuracy. CEB is instantly constructed from three ECG leads on the cardiac monitor and displayed instantly allowing immediate cost-effective identification of patients with acute ischemic injury during cardiac rhythm monitoring. PMID:24118724

  2. Detection of Babesia canis vogeli and Hepatozoon canis in canine blood by a single-tube real-time fluorescence resonance energy transfer polymerase chain reaction assay and melting curve analysis.

    PubMed

    Kongklieng, Amornmas; Intapan, Pewpan M; Boonmars, Thidarut; Thanchomnang, Tongjit; Janwan, Penchom; Sanpool, Oranuch; Lulitanond, Viraphong; Taweethavonsawat, Piyanan; Chungpivat, Sudchit; Maleewong, Wanchai

    2015-03-01

    A real-time fluorescence resonance energy transfer polymerase chain reaction (qFRET PCR) coupled with melting curve analysis was developed for detection of Babesia canis vogeli and Hepatozoon canis infections in canine blood samples in a single tube assay. The target of the assay was a region within the 18S ribosomal RNA gene amplified in either species by a single pair of primers. Following amplification from the DNA of infected dog blood, a fluorescence melting curve analysis was done. The 2 species, B. canis vogeli and H. canis, could be detected and differentiated in infected dog blood samples (n = 37) with high sensitivity (100%). The detection limit for B. canis vogeli was 15 copies of a positive control plasmid, and for H. canis, it was 150 copies of a positive control plasmid. The assay could simultaneously distinguish the DNA of both parasites from the DNA of controls. Blood samples from 5 noninfected dogs were negative, indicating high specificity. Several samples can be run at the same time. The assay can reduce misdiagnosis and the time associated with microscopic examination, and is not prone to the carryover contamination associated with the agarose gel electrophoresis step of conventional PCR. In addition, this qFRET PCR method would be useful to accurately determine the range of endemic areas or to discover those areas where the 2 parasites co-circulate. © 2015 The Author(s).

  3. Effect of Light Quality on Stomatal Opening in Leaves of Xanthium strumarium L.

    PubMed

    Sharkey, T D; Raschke, K

    1981-11-01

    Flux response curves were determined at 16 wavelengths of light for the conductance for water vapor of the lower epidermis of detached leaves of Xanthium strumarium L. An action spectrum of stomatal opening resulted in which blue light (wavelengths between 430 and 460 nanometers) was nearly ten times more effective than red light (wavelengths between 630 and 680 nanometers) in producing a conductance of 15 centimoles per square meter per second. Stomata responded only slightly to green light. An action spectrum of stomatal responses to red light corresponded to that of CO(2) assimilation; the inhibitors of photosynthetic electron transport, cyanazine (2-chloro-4[1-cyano-1-methylethylamino]-6-ethylamino-s-triazine) and 3-(3,4-dichlorophenyl)-1,1-dimethylurea, eliminated the response to red light. This indicates that light absorption by chlorophyll is the cause of stomatal sensitivity to red light. Determination of flux response curves on leaves in the normal position (upper epidermis facing the light) or in the inverted position (lower epidermis facing the light) led to the conclusion that the photoreceptors for blue as well as for red light are located on or near the surfaces of the leaves; presumably they are in the guard cells themselves.

  4. Diagnostic value of survivin for malignant pleural effusion: a clinical study and meta-analysis.

    PubMed

    Tian, Panwen; Shen, Yongchun; Wan, Chun; Yang, Ting; An, Jing; Yi, Qun; Chen, Lei; Wang, Tao; Wang, Ye; Wen, Fuqiang

    2014-01-01

    To investigate the diagnostic accuracy of survivin for malignant pleural effusion (MPE). Pleural effusion samples were collected from 40 MPE patients and 45 non-MPE patients. Pleural levels of survivin were measured by ELISA. Literature search was performed in Pubmed and Embase to identify studies regarding the usefulness of survivin to diagnose MPE. Data were retrieved and the pooled sensitivity, specificity and other diagnostic indexes were calculated. The summary receiver operating characteristics (SROC) curve was used to determine the overall diagnostic accuracy. The pleural levels of survivin were higher in MPE patients than non-MPE patients (844.17 ± 358.30 vs. 508.08 ± 169.58 pg/ml, P < 0.05), at a cut-off value of 683.2 pg/ml, the sensitivity and specificity were 57.50% and 88.89%, respectively. A total of six studies were included in present meta-analysis, the overall diagnostic estimates were: sensitivity 0.74 (95% CI: 0.59-0.85); specificity, 0.85 (95% CI: 0.79-0.89); positive likelihood ratio, 4.79 (95% CI: 3.48-6.61); negative likelihood ratio, 0.31 (95% CI: 0.19-0.50), and diagnostic odds ratio, 15.59 (95% CI: 7.69-31.61). The area under SROC curve was 0.86 (95% CI: 0.82-0.89). Our study confirms that the pleural survivin plays a role in the diagnosis of MPE. More studies at a large scale should be performed to validate our findings.

  5. Smelling the Diagnosis: The Electronic Nose as Diagnostic Tool in Inflammatory Arthritis. A Case-Reference Study.

    PubMed

    Brekelmans, Marjolein P; Fens, Niki; Brinkman, Paul; Bos, Lieuwe D; Sterk, Peter J; Tak, Paul P; Gerlag, Daniëlle M

    2016-01-01

    To investigate whether exhaled breath analysis using an electronic nose can identify differences between inflammatory joint diseases and healthy controls. In a cross-sectional study, the exhaled breath of 21 rheumatoid arthritis (RA) and 18 psoriatic arthritis (PsA) patients with active disease was compared to 21 healthy controls using an electronic nose (Cyranose 320; Smiths Detection, Pasadena, CA, USA). Breathprints were analyzed with principal component analysis, discriminant analysis, and area under curve (AUC) of receiver operating characteristics (ROC) curves. Volatile organic compounds (VOCs) were identified by gas chromatography and mass spectrometry (GC-MS), and relationships between breathprints and markers of disease activity were explored. Breathprints of RA patients could be distinguished from controls with an accuracy of 71% (AUC 0.75, 95% CI 0.60-0.90, sensitivity 76%, specificity 67%). Breathprints from PsA patients were separated from controls with 69% accuracy (AUC 0.77, 95% CI 0.61-0.92, sensitivity 72%, specificity 71%). Distinction between exhaled breath of RA and PsA patients exhibited an accuracy of 69% (AUC 0.72, 95% CI 0.55-0.89, sensitivity 71%, specificity 72%). There was a positive correlation in RA patients of exhaled breathprints with disease activity score (DAS28) and number of painful joints. GC-MS identified seven key VOCs that significantly differed between the groups. Exhaled breath analysis by an electronic nose may play a role in differential diagnosis of inflammatory joint diseases. Data from this study warrant external validation.

  6. Validation of the Polish version of the Hospital Anxiety and Depression Scale for anxiety disorders in patients with epilepsy.

    PubMed

    Wiglusz, Mariusz S; Landowski, Jerzy; Cubała, Wiesław J

    2018-05-24

    Anxiety disorders are frequent comorbid disorders in patients with epilepsy (PWEs). The availability of validated screening instruments to detect anxiety disorders in PWEs is limited. The aim of the present study was to validate the Polish version of the Hospital Anxiety and Depression Scale (HADS) in adult PWEs for the detection of anxiety disorders. A total of 96 outpatients with epilepsy completed the self-reported symptom scale, the HADS, and were diagnosed using the structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) axis I disorders (SCID-I). The sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), and receiver operating characteristic (ROC) curves were assessed to determine the optimal threshold scores for the HADS anxiety subscale (HADS-A). Receiver operating characteristic analyses showed areas under the curve at 80.8%. For diagnoses of anxiety disorder, the HADS-A demonstrated the best psychometric properties for a cutoff score ≥10 with sensitivity of 81.3%, specificity of 70.0%, PPV of 31.5%, and NPV of 94.9%. The HADS-A proved to be a valid and reliable psychometric instrument in terms of screening for anxiety disorders in our sample of PWEs. In the epilepsy setting, the HADS-A maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing anxiety disorders with an optimum cutoff score ≥10. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    PubMed

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  8. Single curved fiber sedimentation under gravity

    Treesearch

    Xiaoying Rong; Dewei Qi; Junyong Zhu

    2005-01-01

    Dynamics of single curved fiber sedimentation under the gravity are simulated by using lattice Boltzmann method. The results of migration and rotation of the curved fiber at different Reynolds numbers are reported. The results show that the rotation and migration processes are sensitive to the curvature of the fiber.

  9. Single curved fiber sedimentation under gravity

    Treesearch

    Xiaoying Rong; Dewei Qi; Guowei He; Jun Yong Zhu; Tim Scott

    2008-01-01

    Dynamics of single curved fiber sedimentation under gravity are simulated by using the lattice Boltzmann method. The results of migration and rotation of the curved fiber at different Reynolds numbers are reported. The results show that the rotation and migration processes are sensitive to the curvature of the fiber.

  10. Average latitudinal variation in ultraviolet radiation at the earth's surface. [biological sensitivity and dosage

    NASA Technical Reports Server (NTRS)

    Johnson, F. S.; Mo, T.; Green, A. E. S.

    1976-01-01

    Tabulated values are presented for ultraviolet radiation at the earth's surface as a function of wavelength, latitude, and season, for clear sky and seasonally and latitudinally averaged ozone amounts. These tabulations can be combined with any biological sensitivity function in order to obtain the seasonal and latitudinal variation of the corresponding effective doses. The integrated dosages, based on the erythemal sensitivity curve and on the Robertson-Berger sunburn-meter sensitivity curve, have also been calculated, and these are found to vary with latitude and season in very nearly the same way as 307 and 314 nm radiation, respectively.

  11. Diagnostic Performance of Narrow Band Imaging for Nasopharyngeal Cancer: A Systematic Review and Meta-analysis.

    PubMed

    Sun, Changling; Zhang, Yayun; Han, Xue; Du, Xiaodong

    2018-03-01

    Objective The purposes of this study were to verify the effectiveness of the narrow band imaging (NBI) system in diagnosing nasopharyngeal cancer (NPC) as compared with white light endoscopy. Data Sources PubMed, Cochrane Library, EMBASE, CNKI, and Wan Fang databases. Review Methods Data analyses were performed with Meta-Disc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with a Deeks asymmetry test. The registry number of the protocol published on PROSPERO is CRD42015026244. Results This meta-analysis included 10 studies of 1337 lesions. For NBI diagnosis of NPC, the pooled values were as follows: sensitivity, 0.83 (95% CI, 0.80-0.86); specificity, 0.91 (95% CI, 0.89-0.93); positive likelihood ratio, 8.82 (95% CI, 5.12-15.21); negative likelihood ratio, 0.18 (95% CI, 0.12-0.27); and diagnostic odds ratio, 65.73 (95% CI, 36.74-117.60). The area under the curve was 0.9549. For white light endoscopy in diagnosing NPC, the pooled values were as follows: sensitivity, 0.79 (95% CI, 0.75-0.83); specificity, 0.87 (95% CI, 0.84-0.90); positive likelihood ratio, 5.02 (95% CI, 1.99-12.65); negative likelihood ratio, 0.34 (95% CI, 0.24-0.49); and diagnostic odds ratio, 16.89 (95% CI, 5.98-47.66). The area under the curve was 0.8627. The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 0.326. No marked publication bias ( P = .68) existed in this meta-analysis. Conclusion The sensitivity and specificity of NBI for the diagnosis of NPC are similar to those of white light endoscopy, and the potential value of NBI for the diagnosis of NPC needs to be validated further.

  12. FEV1/FEV6 in Primary Care Is a Reliable and Easy Method for the Diagnosis of COPD.

    PubMed

    Wang, Shengyu; Gong, Wei; Tian, Yao; Zhou, Jing

    2016-03-01

    FEV6 can be used as a convenient alternative to FVC. The aim of this study was to determine an alternative to the fixed cutoff points of FEV1/FVC <0.70 suitable for FEV1/FEV6 in primary care. Pulmonary function testing was conducted on volunteers recruited from 4 community centers in Xi'an, China, between July and August 2012. Participants underwent 3 FVC maneuvers. The maneuver with the best FEV1 was retained. FVC, FEV1, and FEV6 were measured by portable spirometer. The receiver operating characteristic curves that corresponded to the optimal combination of sensitivity and specificity for FEV1/FEV6 were determined. A kappa test was used to compare the agreement between FEV1/FVC and FEV1/FEV6. The positive predictive value and negative predictive value were also calculated. A total of 767 volunteers participated in this study, of whom 297 were male and 470 were female. Considering FEV1/FVC <0.70 as the accepted standard for COPD, the area under the curve was 98% (P < .001), and the FEV1/FEV6 cutoff, corresponding to the greatest sum of sensitivity and specificity, was 0.72. For the total population, the FEV1/FEV6 sensitivity, specificity, positive predictive value, and negative predictive value were 96.9, 98.8, 95.8, and 99.2%, respectively. The agreement between the 2 cutoff points was excellent, and the kappa value was 0.954. FEV1/FEV6 <0.72 can be used in primary care as a valid alternative to FEV1/FVC <0.70 as a fixed cutoff point for the detection of COPD in adults. This study suggests that FEV1/FEV6 is an effective and well validated option that should be used in primary care to detect COPD, which is a rampant problem. Copyright © 2016 by Daedalus Enterprises.

  13. The Glittre-ADL Test Cut-Off Point to Discriminate Abnormal Functional Capacity in Patients with COPD.

    PubMed

    Gulart, Aline Almeida; Munari, Anelise Bauer; Klein, Suelen Roberta; Santos da Silveira, Lucas; Mayer, Anamaria Fleig

    2018-02-01

    The study objective was to determine a cut-off point for the Glittre activities of daily living (ADL)test (TGlittre) to discriminate patients with normal and abnormal functional capacity. Fifty-nine patients with moderate to very severe COPD (45 males; 65 ± 8.84 years; BMI: 26 ± 4.78 kg/m 2 ; FEV 1 : 35.3 ± 13.4% pred) were evaluated for spirometry, TGlittre, 6-minute walk test (6 MWT), physical ADL, modified Medical Research Council scale (mMRC), BODE index, Saint George's Respiratory Questionnaire (SGRQ), and COPD Assessment Test (CAT). The receiver operating characteristic (ROC) curve was used to determine the cut-off point for TGlittre in order to discriminate patients with 6 MWT < 82% pred. The ROC curve indicated a cut-off point of 3.5 minutes for the TGlittre (sensitivity = 92%, specificity = 83%, and area under the ROC curve = 0.95 [95% CI: 0.89-0.99]). Patients with abnormal functional capacity had higher mMRC (median difference 1 point), CAT (mean difference: 4.5 points), SGRQ (mean difference: 12.1 points), and BODE (1.37 points) scores, longer time of physical activity <1.5 metabolic equivalent of task (mean difference: 47.9 minutes) and in sitting position (mean difference: 59.4 minutes) and smaller number of steps (mean difference: 1,549 minutes); p < 0.05 for all. In conclusion, the cut-off point of 3.5 minutes in the TGlittre is sensitive and specific to distinguish COPD patients with abnormal and normal functional capacity.

  14. Diagnostic value of DIAGNOdent in detecting caries under composite restorations of primary molars.

    PubMed

    Sichani, Ava Vali; Javadinejad, Shahrzad; Ghafari, Roshanak

    2016-01-01

    Direct observation cannot detect caries under restorations; therefore, the aim of this study was to compare the accuracy of radiographs and DIAGNOdent in detecting caries under restorations in primary teeth using histologic evaluation. A total of 74 previously extracted primary molars (37 with occlusal caries and 37 without caries) were used. Class 1 cavity preparations were made on each tooth by a single clinician and then the preparations were filled with composite resin. The accuracy of radiographs and DIAGNOdent in detecting caries was compared using histologic evaluation. The data were analyzed by SPSS version 21 using Chi-square, Mc Namara statistical tests and receiver operating characteristic curve. The significance was set at 0.05. The sensitivity and specificity for DIAGNOdent were 70.97 and 83.72, respectively. Few false negative results were observed, and the positive predictive value was high (+PV = 75.9) and the area under curve was more than 0.70 therefore making DIAGNOdenta great method for detecting caries (P = 0.0001). Two observers evaluated the radiographs and both observers had low sensitivity ( first observer: 48.39) (second observer: 51.61) and high specificity (both observers: 79.07). The +PV was lower than DIAGNOdent and the area under curve for both observers was less than 0.70. However, the difference between the two methods was not significant. DIAGNOdent showed a greater accuracy in detecting secondary caries under primary molar restorations, compared to radiographs. Although DIAGNOdent is an effective method for detecting caries under composite restorations, it is better to be used as an adjunctive method alongside other detecting procedures.

  15. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results.

    PubMed

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful.

  16. Antibody against mutated citrullinated vimentin: a new sensitive marker in the diagnosis of rheumatoid arthritis.

    PubMed

    Wagner, Ernst; Skoumal, M; Bayer, P M; Klaushofer, K

    2009-09-01

    The aim of this study was to determine the performance of antibodies against mutated citrullinated vimentin (anti-MCV) in comparison with antibodies to cyclic citrullinated peptides (anti-CCP) in patients with rheumatoid arthritis (RA). Serum levels of anti-MCV and anti-CCP were determined in 193 patients with RA and 332 controls, and sensitivity and specificity were calculated. In a separate analysis of 86 patients, the anti-MCV levels were compared to disease activity. Sensitivity of anti-MCV versus anti-CCP was 71.5 and 69.4%, specificity was 81.3 and 97.6%, respectively. The ROC curves showed higher specificity and an advantage of anti-CCP. In seronegative RA patients the sensitivity of anti-MCV was superior over anti-CCP. Anti-MCV positivities also occurred in systemic lupus erythematosus and Sjoegren's syndrome. In a subgroup of 86 RA patients we found a significant correlation between anti-MCV and disease activity. Anti-MCV appears to be an important marker for the diagnosis of RA, and correlates also with disease activity.

  17. Evaluation of an inpatient fall risk screening tool to identify the most critical fall risk factors in inpatients.

    PubMed

    Hou, Wen-Hsuan; Kang, Chun-Mei; Ho, Mu-Hsing; Kuo, Jessie Ming-Chuan; Chen, Hsiao-Lien; Chang, Wen-Yin

    2017-03-01

    To evaluate the accuracy of the inpatient fall risk screening tool and to identify the most critical fall risk factors in inpatients. Variations exist in several screening tools applied in acute care hospitals for examining risk factors for falls and identifying high-risk inpatients. Secondary data analysis. A subset of inpatient data for the period from June 2011-June 2014 was extracted from the nursing information system and adverse event reporting system of an 818-bed teaching medical centre in Taipei. Data were analysed using descriptive statistics, receiver operating characteristic curve analysis and logistic regression analysis. During the study period, 205 fallers and 37,232 nonfallers were identified. The results revealed that the inpatient fall risk screening tool (cut-off point of ≥3) had a low sensitivity level (60%), satisfactory specificity (87%), a positive predictive value of 2·0% and a negative predictive value of 99%. The receiver operating characteristic curve analysis revealed an area under the curve of 0·805 (sensitivity, 71·8%; specificity, 78%). To increase the sensitivity values, the Youden index suggests at least 1·5 points to be the most suitable cut-off point for the inpatient fall risk screening tool. Multivariate logistic regression analysis revealed a considerably increased fall risk in patients with impaired balance and impaired elimination. The fall risk factor was also significantly associated with days of hospital stay and with admission to surgical wards. The findings can raise awareness about the two most critical risk factors for falls among future clinical nurses and other healthcare professionals and thus facilitate the development of fall prevention interventions. This study highlights the needs for redefining the cut-off points of the inpatient fall risk screening tool to effectively identify inpatients at a high risk of falls. Furthermore, inpatients with impaired balance and impaired elimination should be closely monitored by nurses to prevent falling during hospitalisations. © 2016 John Wiley & Sons Ltd.

  18. Validity and reliability of Patient Health Questionnaire-9 and Patient Health Questionnaire-2 to screen for depression among college students in China.

    PubMed

    Zhang, Ying-Li; Liang, Wei; Chen, Zuo-Ming; Zhang, Hong-Mei; Zhang, Jian-Hong; Weng, Xiao-Qin; Yang, Shi-Chang; Zhang, Lei; Shen, Li-Juan; Zhang, Ya-Lin

    2013-12-01

    This study examined the validity and reliability of the Patient Health Questionnaire-9 (PHQ-9) and Patient Health Questionnaire-2 (PHQ-2). The optimal cutoff score when screening for depression among Chinese college students was also determined. A total of 959 participants completed the PHQ-9 and the Beck Depression Inventory (BDI) questionnaire. The Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders was used to diagnose depression. Statistical tests were performed to determine the reliability, validity, and receiver operating characteristic curve of the data. The concurrent validity was tested by examining associations between PHQ-9 and BDI. The sensitivity and specificity, as well as the positive and negative predictive values, were calculated for different cutoff scores of PHQ-9 and PHQ-2. The internal consistency values of PHQ-9 and PHQ-2 were 0.854 and 0.727, respectively. The test-retest reliability values of PHQ-9 and PHQ-2 were 0.873 and 0.829, respectively. The scores of PHQ-9 (r = 0.790) and PHQ-2 (r = 0.651) were significantly associated with that of BDI. PHQ-9 had an optimal cutoff score of 11, which indicated a sensitivity of 0.89 and a specificity of 0.97, with an area under the curve of 0.977 (95% confidence interval: 0.966-0.988). The PHQ-2 demonstrated satisfactory sensitivity (0.81) and specificity (0.96) at the cutoff score of 3, and its area under the curve was 0.939. The PHQ-9 and the PHQ-2 are valid and reliable tools to screen depression in Chinese college students. For screening purposes, cutoff scores of 11 and 3 are recommended for PHQ-9 and PHQ-2, respectively. Copyright © 2013 Wiley Publishing Asia Pty Ltd.

  19. The prevalence of anti-acetylcholinesterase antibodies in autoimmune disease.

    PubMed

    Geen, J; Howells, R C; Ludgate, M; Hullin, D A; Hogg, S I

    2004-12-01

    A robust and precise enzyme linked immunosorbent assay (ELISA) with proven sensitivity and specificity has been employed to detect human antibodies (allogenic/autogenic) to human acetylcholinesterase (AChE). The sensitivity of the method has been established using mouse monoclonal antibodies (0.8 ng/ml) and uniquely, human sera positive for anti-Yt(a) allogenic antibodies, to one phenotypic form (most common) of human AChE. The latter was also used as the positive human control to ensure functionality of the assay. The ELISA method was used to establish a normal distribution curve for absorbance values employing sera from healthy blood donors Subsequently, the ELISA was employed to investigate the prevalence of anti-AChE antibodies in patients with confirmed autoimmune disease and patients with non-autoimmune thyroid disease (diseased control). The results indicate that there is not a high prevalence of anti-AChE antibodies in patients with confirmed autoimmune disease. The lack of anti-AChE autoantibodies in patients' with clinically apparent Graves' ophthalmopathy, mitigates against there being a causal role of such antibodies in Graves' associated eye disease.

  20. Detection and quantitation of trace phenolphthalein (in pharmaceutical preparations and in forensic exhibits) by liquid chromatography-tandem mass spectrometry, a sensitive and accurate method.

    PubMed

    Sharma, Kakali; Sharma, Shiba P; Lahiri, Sujit C

    2013-01-01

    Phenolphthalein, an acid-base indicator and laxative, is important as a constituent of widely used weight-reducing multicomponent food formulations. Phenolphthalein is an useful reagent in forensic science for the identification of blood stains of suspected victims and for apprehending erring officials accepting bribes in graft or trap cases. The pink-colored alkaline hand washes originating from the phenolphthalein-smeared notes can easily be determined spectrophotometrically. But in many cases, colored solution turns colorless with time, which renders the genuineness of bribe cases doubtful to the judiciary. No method is known till now for the detection and identification of phenolphthalein in colorless forensic exhibits with positive proof. Liquid chromatography-tandem mass spectrometry had been found to be most sensitive, accurate method capable of detection and quantitation of trace phenolphthalein in commercial formulations and colorless forensic exhibits with positive proof. The detection limit of phenolphthalein was found to be 1.66 pg/L or ng/mL, and the calibration curve shows good linearity (r(2) = 0.9974). © 2012 American Academy of Forensic Sciences.

  1. Do Subjective Alcohol Screening Tools Correlate with Biomarkers Among High-Risk Transgender Women and Men Who Have Sex with Men in Lima, Peru?

    PubMed

    Herrera, M C; Konda, K A; Leon, S R; Brown, B; Calvo, G M; Salvatierra, H J; Caceres, C F; Klausner, J D; Deiss, R

    2017-11-01

    Alcohol abuse can influence sexual risk behavior; however, its measurement is not straightforward. This study compared self-reported alcohol use, via the AUDIT and CAGE, with levels of phosphatidylethanol (Peth), a phospholipid biomarker that forms with chronic, heavy drinking, among high-risk MSM and TW in Lima, Peru. Chi square, Fisher's exact, Wilcoxon ranksum tests compared the instruments. Receiver operating curves determined sensitivity and specificity of the self-reported measures. Among 69 MSM and 17 TW, PEth was positive for 86% (95% CI 77-93%) of participants, while 67% reported binge-drinking in the last 2 weeks. The AUDIT classified 25% as hazardous drinkers while CAGE identified 6% as problem drinkers. Self-reported binge drinking was more sensitive than the AUDIT for PEth positivity (71% vs. 27%, p = 0.022). Among high-risk MSM and TW in Lima, validated, self-report measures of alcohol abuse underestimated biological measures. Further research correlating bio-markers and self-reported alcohol abuse measures is needed.

  2. The affect of low-coherent light on microbial colony forming ability and morphology of some gram-positive and gram-negative bacteria

    NASA Astrophysics Data System (ADS)

    Popov, Denis E.; Tuchina, Elena S.; Chernova, Julia A.; Podshibyakin, Dmitry; Rudik, Dmitry V.; Samsonova, Maria; Gromov, Igor; Tuchin, Valery V.

    2005-06-01

    Gram-negative E. coli, gram-positive facultative anaerobe cocci Staphylococcus lugdensis, Micrococcus halobius, and Stomatococcus mucilaginosus as subjects of study were chosen. LEDs with spectrum maxima at 405 nm (without any exogenous sensitizer) and 660 nm (in conjunction with methylene blue) and power densities of 23 mW/cm2 and 5.7 mW/cm2 accordingly as continuous light sources were chosen. Photosensitized light's affect by methylene blue was studied on E. coli only. The original scheme of experiment set up was developed. It permits one to increase expositions quantity in each experiment for more certain trend's construction over dose curves and decrease parasite flora sowing. As a result of accomplished studies it was established that blue low-coherent light have unalike weak light's dose depending suppressing effect on cocci whereas red low-coherent light have a moderate dose-depended suppressing effect at low irradiation doses and a moderate dose-depended stimulating effect at high irradiation doses on sensitized by MeBlue E. coli. For all ofthis, but Staphylococcus morphology changes were observed.

  3. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    PubMed

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.

  4. Cone photoreceptor sensitivities and unique hue chromatic responses: correlation and causation imply the physiological basis of unique hues.

    PubMed

    Pridmore, Ralph W

    2013-01-01

    This paper relates major functions at the start and end of the color vision process. The process starts with three cone photoreceptors transducing light into electrical responses. Cone sensitivities were once expected to be Red Green Blue color matching functions (to mix colors) but microspectrometry proved otherwise: they instead peak in yellowish, greenish, and blueish hues. These physiological functions are an enigma, unmatched with any set of psychophysical (behavioral) functions. The end-result of the visual process is color sensation, whose essential percepts are unique (or pure) hues red, yellow, green, blue. Unique hues cannot be described by other hues, but can describe all other hues, e.g., that hue is reddish-blue. They are carried by four opponent chromatic response curves but the literature does not specify whether each curve represents a range of hues or only one hue (a unique) over its wavelength range. Here the latter is demonstrated, confirming that opponent chromatic responses define, and may be termed, unique hue chromatic responses. These psychophysical functions also are an enigma, unmatched with any physiological functions or basis. Here both enigmas are solved by demonstrating the three cone sensitivity curves and the three spectral chromatic response curves are almost identical sets (Pearson correlation coefficients r from 0.95-1.0) in peak wavelengths, curve shapes, math functions, and curve crossover wavelengths, though previously unrecognized due to presentation of curves in different formats, e.g., log, linear. (Red chromatic response curve is largely nonspectral and thus derives from two cones.) Close correlation combined with deterministic causation implies cones are the physiological basis of unique hues. This match of three physiological and three psychophysical functions is unique in color vision.

  5. Cone Photoreceptor Sensitivities and Unique Hue Chromatic Responses: Correlation and Causation Imply the Physiological Basis of Unique Hues

    PubMed Central

    Pridmore, Ralph W.

    2013-01-01

    This paper relates major functions at the start and end of the color vision process. The process starts with three cone photoreceptors transducing light into electrical responses. Cone sensitivities were once expected to be Red Green Blue color matching functions (to mix colors) but microspectrometry proved otherwise: they instead peak in yellowish, greenish, and blueish hues. These physiological functions are an enigma, unmatched with any set of psychophysical (behavioral) functions. The end-result of the visual process is color sensation, whose essential percepts are unique (or pure) hues red, yellow, green, blue. Unique hues cannot be described by other hues, but can describe all other hues, e.g., that hue is reddish-blue. They are carried by four opponent chromatic response curves but the literature does not specify whether each curve represents a range of hues or only one hue (a unique) over its wavelength range. Here the latter is demonstrated, confirming that opponent chromatic responses define, and may be termed, unique hue chromatic responses. These psychophysical functions also are an enigma, unmatched with any physiological functions or basis. Here both enigmas are solved by demonstrating the three cone sensitivity curves and the three spectral chromatic response curves are almost identical sets (Pearson correlation coefficients r from 0.95–1.0) in peak wavelengths, curve shapes, math functions, and curve crossover wavelengths, though previously unrecognized due to presentation of curves in different formats, e.g., log, linear. (Red chromatic response curve is largely nonspectral and thus derives from two cones.) Close correlation combined with deterministic causation implies cones are the physiological basis of unique hues. This match of three physiological and three psychophysical functions is unique in color vision. PMID:24204755

  6. CMV viral load measurements in whole blood and plasma--which is best following renal transplantation?

    PubMed

    Barrett-Muir, W; Breuer, J; Millar, C; Thomas, J; Jeffries, D; Yaqoob, M; Aitken, C

    2000-07-15

    Quantitative commercial assays for cytomegalovirus (CMV) detection have recently been developed. Their role in the management of patients after transplantation needs to be evaluated. Widespread use of these assays will allow for comparison of results between centers and meaningful interpretation of the significance of viral load measurements. Sequential samples from 52 patients after renal transplantation were tested in the murex hybrid capture assay (HCA) and the Roche Amplicor CMV DNA assay (QPCR) and correlated with the development of CMV disease. A comparison of viral loads in plasma and whole blood was also made. Both assays were sensitive and detected all cases of CMV disease. The specificity and positive predictive value increased from 0.34 and 0.36 to 0.85 and 0.96 for the HCA and 0.37, 0.37 to 0.72 and 0.63 for the QPCR following a receiver operator curve analysis. Higher viral loads were measured using the HCA compared to the QPCR. Response to ganciclovir was associated with a greater than 80% reduction in viral load by HCA or greater than 70% using the QPCR. Both assays were highly sensitive. By using a receiver operator curve analysis a cutoff viral load can be determined which maximizes the clinical utility of these assays.

  7. A novel assay for detecting canine parvovirus using a quartz crystal microbalance biosensor.

    PubMed

    Kim, Yong Kwan; Lim, Seong-In; Choi, Sarah; Cho, In-Soo; Park, Eun-Hye; An, Dong-Jun

    2015-07-01

    Rapid and accurate diagnosis is crucial to reduce both the shedding and clinical signs of canine parvovirus (CPV). The quartz crystal microbalance (QCM) is a new tool for measuring frequency changes associated with antigen-antibody interactions. In this study, the QCM biosensor and ProLinker™ B were used to rapidly diagnosis CPV infection. ProLinker™ B enables antibodies to be attached to a gold-coated quartz surface in a regular pattern and in the correct orientation for antigen binding. Receiver operating characteristics (ROC) curves were used to set a cut-off value using reference CPVs (two groups: one CPV-positive and one CPV-negative). The ROC curves overlapped and the point of intersection was used as the cut-off value. A QCM biosensor with a cut-off value of -205 Hz showed 95.4% (104/109) sensitivity and 98.0% (149/152) specificity when used to test 261 field fecal samples compared to PCR. In conclusion, the QCM biosensor described herein is eminently suitable for the rapid diagnosis of CPV infection with high sensitivity and specificity. Therefore, it is a promising analytical tool that will be useful for clinical diagnosis, which requires rapid and reliable analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Utility of functional status for classifying community versus institutional discharges after inpatient rehabilitation for stroke.

    PubMed

    Reistetter, Timothy A; Graham, James E; Deutsch, Anne; Granger, Carl V; Markello, Samuel; Ottenbacher, Kenneth J

    2010-03-01

    To evaluate the ability of patient functional status to differentiate between community and institutional discharges after rehabilitation for stroke. Retrospective cross-sectional design. Inpatient rehabilitation facilities contributing to the Uniform Data System for Medical Rehabilitation. Patients (N=157,066) receiving inpatient rehabilitation for stroke from 2006 and 2007. Not applicable. Discharge FIM rating and discharge setting (community vs institutional). Approximately 71% of the sample was discharged to the community. Receiver operating characteristic curve analyses revealed that FIM total performed as well as or better than FIM motor and FIM cognition subscales in differentiating discharge settings. Area under the curve for FIM total was .85, indicating very good ability to identify persons discharged to the community. A FIM total rating of 78 was identified as the optimal cut point for distinguishing between positive (community) and negative (institution) tests. This cut point yielded balanced sensitivity and specificity (both=.77). Discharge planning is complex, involving many factors. Identifying a functional threshold for classifying discharge settings can provide important information to assist in this process. Additional research is needed to determine if the risks and benefits of classification errors justify shifting the cut point to weight either sensitivity or specificity of FIM ratings. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Rapid and specific detection of Salmonella in water samples using real-time PCR and High Resolution Melt (HRM) curve analysis.

    PubMed

    van Blerk, G N; Leibach, L; Mabunda, A; Chapman, A; Louw, D

    2011-01-01

    A real-time PCR assay combined with a pre-enrichment step for the specific and rapid detection of Salmonella in water samples is described. Following amplification of the invA gene target, High Resolution Melt (HRM) curve analysis was used to discriminate between products formed and to positively identify invA amplification. The real-time PCR assay was evaluated for specificity and sensitivity. The assay displayed 100% specificity for Salmonella and combined with a 16-18 h non-selective pre-enrichment step, the assay proved to be highly sensitive with a detection limit of 1.0 CFU/ml for surface water samples. The detection assay also demonstrated a high intra-run and inter-run repeatability with very little variation in invA amplicon melting temperature. When applied to water samples received routinely by the laboratory, the assay showed the presence of Salmonella in particularly surface water and treated effluent samples. Using the HRM based assay, the time required for Salmonella detection was drastically shortened to less than 24 h compared to several days when using standard culturing methods. This assay provides a useful tool for routine water quality monitoring as well as for quick screening during disease outbreaks.

  10. Evaluation of Basal Serum or Plasma Cortisol Concentrations for the Diagnosis of Hypoadrenocorticism in Dogs.

    PubMed

    Gold, A J; Langlois, D K; Refsal, K R

    2016-11-01

    Previous studies that included limited numbers of affected dogs have suggested basal cortisol concentrations ≤55 nmol/L (2 μg/dL) are sensitive, but nonspecific, for a diagnosis of hypoadrenocorticism. A detailed assessment of the diagnostic utility of basal cortisol concentrations is warranted. To evaluate the utility of basal cortisol concentrations for the diagnosis of hypoadrenocorticism in a large number of dogs, including those with and without serum electrolyte abnormalities. Five hundred and twenty-two dogs, including 163 dogs with hypoadrenocorticism, 351 dogs with nonadrenal gland illness, and 8 dogs with equivocal results. Retrospective study. Basal and post-ACTH cortisol concentrations and sodium and potassium concentrations were collected from medical records. A receiver operating characteristic (ROC) curve was constructed for basal cortisol concentrations by standard methodologies. Sensitivity, specificity, and predictive values were determined for various cut-points. The area under the ROC curve was 0.988 and was similarly excellent regardless of serum electrolyte concentrations. At the most discriminatory cut-point of 22 nmol/L (0.8 μg/dL), sensitivity and specificity were 96.9 and 95.7%, respectively. A basal cortisol concentration of ≤55 nmol/L (2 μg/dL) resulted in a sensitivity of 99.4%. Conversely, a basal cortisol concentration of ≤5.5 nmol/L (0.19 μg/dL) resulted in a specificity of 99.1%. Similar to findings in previous studies, basal cortisol concentrations >55 nmol/L (2 μg/dL) are useful in excluding a diagnosis of hypoadrenocorticism. Interestingly, excellent specificities and positive predictive values were observed at lower cut-point cortisol concentrations. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. [Non-invasive fibrosis indexes in predicting acute liver function deterioration after transcatheter arterial chemoembolization].

    PubMed

    Song, Y P; Zhao, Q Y; Li, S; Wang, H; Wu, P H

    2016-03-08

    To investigate the ability of two non-invasive fibrosis indexes-APRI, i. e. aspartate transaminase (AST) to platelet (PLT) ratio index, and fibrosis index based on the 4 factors (FIB-4)score in predicting ALFD in patients with unresectable primary HCC and underwent TACE. Clinical data of those patients treated with TACE in Department of Interventional Radiology of the Center from Jan 2010 to Aug 2014 were investigated retrospectively. A total of 366 cases were enrolled after randomized selection, 62 (18.5%) of which developed ALFD after TACE. Child-Pugh score, APRI and FIB-4 score in every case were calculated, receiver operating characteristic (ROC) curve of each model were performed and the predictive abilities of them were assessed by area under the curve (AUC), positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity. The AUC of Child-Pugh score, APRI and FIB-4 score were 0.783, 0.752 and 0.758 respectively, while the difference had no significance in statistics, indicating that predictive accuracies of them were similar. APRI≤1.15 and FIB-4≤3.08 had better NPV (90.6% and 93.6%) and sensitivity (65.6% and 80.0%) than Child-Pugh score>6 (NPV=85.8%, sensitivity=27.4%), PPV and specificity of them are 35.7%, 32.9%, 89.5% and 73.7%, 64.2%, 99.3% respectively. Comparing to Child-Pugh score, APRI and FIB-4 score have similar accuracy but better NPV and sensitivity in predicting post-TACE ALFD. Thereafter they are good for selection of low-risk patients for TACE treatment. Candidates with an APRI≤1.15 or a FIB-4≤3.08 or in Child-Pugh a stage are unlikely to develop ALFD thus could receive TACE safely.

  12. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  13. The performance characteristics of prostate-specific antigen and prostate-specific antigen density in Chinese men.

    PubMed

    Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong

    2017-01-01

    We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P < 0.001) and 0.823 for PSAD (P < 0.001). PSA of 4.5 ng ml-1 had sensitivity of 94.4%, specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, P< 0.001) were significant predictors for prostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.

  14. Component resolved diagnostic study of cow's milk allergy in infants and young children in northern China.

    PubMed

    Li, Junpu; Zhang, Jiayi; Qiong, Cuiya; She, Tiantian; Bian, Ying; Lin, Shuxiang; Li, Huiqiang

    2018-05-30

    Increasing dairy consumption in China has been accompanied by rising incidence of milk allergy. Here we analyzed profiles of specific immunoglobulin E (sIgE) against cow's milk proteins, and assessed their value for milk allergy diagnosis among infants and young children from northern China. Sera collected from 48 patients with milk allergy and 27 negative control subjects was analyzed by enzyme-linked immunosorbent assay to measure sIgE to α-lactalbumin (Bos d 4), β-lactoglobulin (Bos d 5), α-casein (Bos d 9), β-casein (Bos d 11), and κ-casein (Bos d 12). Among milk-allergic individuals, most were sensitized to at least one milk protein; about half were sensitized to Bos d 5, Bos d 9, Bos d 11 and Bos d 12, respectively, while few had positive serum sIgE against Bos d 4. Bos d 12 sIgE had the largest area under curve (AUC) (0.878; 95% CI, 0.800-0.957) and thus showed the best diagnostic performance in discriminating between milk-allergic and non-milk allergic patients, with a sensitivity of 92.6% and specificity of 72.9% using a statistically optimal cut-off value (OD 450nm , 0.191). The combinations of Bos d 5 + Bos d 12 showed an AUC of 0.926, which was larger than for any individual components. Our results revealed inter-individual variation in the sensitization to different milk allergen component. Bos d 12 sIgE showed best performance in diagnosing milk allergy. Milk allergy diagnostic accuracy was further improved using combinations of milk allergen components by application of ROC curves based on logistic regression. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients.

    PubMed

    Nozoe, Masafumi; Mase, Kyoshi; Murakami, Shigefumi; Okada, Makoto; Ogino, Tomoyuki; Matsushita, Kazuhiro; Takashima, Sachie; Yamamoto, Noriyasu; Fukuda, Yoshihiro; Domen, Kazuhisa

    2013-10-01

    Assessment of the degree of air-flow obstruction is important for determining the treatment strategy in COPD patients. However, in some elderly COPD patients, measuring FVC is impossible because of cognitive dysfunction or severe dyspnea. In such patients a simple test of airways obstruction requiring only a short run of tidal breathing would be useful. We studied whether the spontaneous expiratory flow-volume (SEFV) curve pattern reflects the degree of air-flow obstruction in elderly COPD patients. In 34 elderly subjects (mean ± SD age 80 ± 7 y) with stable COPD (percent-of-predicted FEV(1) 39.0 ± 18.5%), and 12 age-matched healthy subjects, we measured FVC and recorded flow-volume curves during quiet breathing. We studied the SEFV curve patterns (concavity/convexity), spirometry results, breathing patterns, and demographics. The SEFV curve concavity/convexity prediction accuracy was examined by calculating the receiver operating characteristic curves, cutoff values, area under the curve, sensitivity, and specificity. Fourteen subjects with COPD had a concave SEFV curve. All the healthy subjects had convex SEFV curves. The COPD subjects who had concave SEFV curves often had very severe airway obstruction. The percent-of-predicted FEV(1)% (32.4%) was the most powerful SEFV curve concavity predictor (area under the curve 0.92, 95% CI 0.83-1.00), and had the highest sensitivity (0.93) and specificity (0.88). Concavity of the SEFV curve obtained during tidal breathing may be a useful test for determining the presence of very severe obstruction in elderly patients unable to perform a satisfactory FVC maneuver.

  16. Eating high fat chow increases the sensitivity of rats to quinpirole-induced discriminative stimulus effects and yawning

    PubMed Central

    Baladi, Michelle G; France, Charles P

    2010-01-01

    Discriminative stimulus effects of directly-acting dopamine receptor agonists (e.g. quinpirole) appear to be mediated by D3 receptors in free-feeding rats. Free access to high fat chow increases sensitivity to quinpirole-induced yawning and the current study examined whether eating high fat chow increases sensitivity to the discriminative stimulus effects of quinpirole. Five rats discriminated between 0.032 mg/kg quinpirole and vehicle while responding under a continuous reinforcement schedule of stimulus shock termination. When rats had free access to high fat chow (discrimination training was suspended), the quinpirole discrimination dose-response curve shifted leftward, possibly indicating enhanced sensitivity at D3 receptors. In the same rats, both the ascending (mediated by D3 receptors) and descending (mediated by D2 receptors) limbs of the dose- response curve for quinpirole-induced yawning shifted leftward. When rats had free access to a standard chow (discrimination training was suspended), the quinpirole discrimination and yawning dose-response curves did not change. Together with published data showing that the discriminative stimulus effects of quinpirole in free- feeding rats are mediated by D3 receptors and the insensitivity of this effect of quinpirole to food restriction (shown to increase sensitivity to D2 but not D3-mediated effects), these results suggest that the leftward shift of the discrimination dose-response curve when rats eat high fat chow is likely due to enhanced sensitivity at D3 receptors. Thus, eating high fat food enhances drug effects in a manner that might impact clinical effects of drugs or vulnerability to drug abuse. PMID:20729718

  17. Eating high-fat chow increases the sensitivity of rats to quinpirole-induced discriminative stimulus effects and yawning.

    PubMed

    Baladi, Michelle G; France, Charles P

    2010-10-01

    Discriminative stimulus effects of direct acting dopamine receptor agonists (e.g. quinpirole) appear to be mediated by D3 receptors in free-feeding rats. Free access to high-fat chow increases sensitivity to quinpirole-induced yawning, and this study examined whether eating high-fat chow increases sensitivity to the discriminative stimulus effects of quinpirole. Five rats discriminated between 0.032 mg/kg quinpirole and vehicle while responding under a continuous reinforcement schedule of stimulus shock termination. When rats had free access to high-fat chow (discrimination training was suspended), the quinpirole discrimination dose-response curve shifted leftward, possibly indicating enhanced sensitivity at D3 receptors. In the same rats, both the ascending (mediated by D3 receptors) and descending (mediated by D2 receptors) limbs of the dose-response curve for quinpirole-induced yawning shifted leftward. When rats had free access to a standard chow (discrimination training was suspended), the quinpirole discrimination and yawning dose-response curves did not change. Together with published data showing that the discriminative stimulus effects of quinpirole in free-feeding rats are mediated by D3 receptors and the insensitivity of this effect of quinpirole to food restriction (shown to increase sensitivity to D2 but not D3-mediated effects), these results suggest that the leftward shift of the discrimination dose-response curve when rats eat high-fat chow is likely because of enhanced sensitivity at D3 receptors. Thus, eating high-fat food enhances drug effects in a manner that might impact clinical effects of drugs or vulnerability to drug abuse.

  18. Assessment of insulin sensitivity by the hyperinsulinemic euglycemic clamp: Comparison with the spectral analysis of photoplethysmography.

    PubMed

    De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte

    2017-01-01

    We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Optimization of Parameter Ranges for Composite Tape Winding Process Based on Sensitivity Analysis

    NASA Astrophysics Data System (ADS)

    Yu, Tao; Shi, Yaoyao; He, Xiaodong; Kang, Chao; Deng, Bo; Song, Shibo

    2017-08-01

    This study is focus on the parameters sensitivity of winding process for composite prepreg tape. The methods of multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis are proposed. The polynomial empirical model of interlaminar shear strength is established by response surface experimental method. Using this model, the relative sensitivity of key process parameters including temperature, tension, pressure and velocity is calculated, while the single-parameter sensitivity curves are obtained. According to the analysis of sensitivity curves, the stability and instability range of each parameter are recognized. Finally, the optimization method of winding process parameters is developed. The analysis results show that the optimized ranges of the process parameters for interlaminar shear strength are: temperature within [100 °C, 150 °C], tension within [275 N, 387 N], pressure within [800 N, 1500 N], and velocity within [0.2 m/s, 0.4 m/s], respectively.

  20. Autonomous Sensor Motes Employing Liquid-Bearing Rotary Stages

    DTIC Science & Technology

    2014-03-06

    breaks off (Fig. 27d) as shown in the sudden change in force, indicating rotor pull off. The minimum of each curve indicates the maximum tensile load...configuration, with marks on the curves at the minimum energy positions are shown in Fig. 39. The minimum energy positions from Fig. 39are plotted as...rates between 5 and 17 Hz rotation rate plotted vs. rotor eccentricity. The minimum energy positions are indicated on each curve . 3.3 Discussion

  1. Can Biomarkers Help Target Maturity-Onset Diabetes of the Young Genetic Testing in Antibody-Negative Diabetes?

    PubMed

    Majidi, Shideh; Fouts, Alexandra; Pyle, Laura; Chambers, Christina; Armstrong, Taylor; Wang, Zhenyuan; Batish, Sat Dev; Klingensmith, Georgeanna; Steck, Andrea K

    2018-02-01

    Maturity-onset diabetes of the young (MODY) is an antibody-negative, autosomal dominant form of diabetes. With the increasing prevalence of diabetes and the expense of MODY testing, markers to identify those who need further genetic testing would be beneficial. We investigated whether HLA genotypes, random C-peptide, and/or high-sensitivity C-reactive protein (hsCRP) levels could be helpful biomarkers for identifying MODY in antibody-negative diabetes. Subjects (N = 97) with diabetes onset ≤age 25, measurable C-peptide (≥0.1 ng/mL), and negative for all four diabetes autoantibodies were enrolled at a large academic center and tested for MODY 1-5 through Athena Diagnostics. A total of 22 subjects had a positive or very likely pathogenic mutation for MODY. Random C-peptide levels were significantly different between MODY-positive and MODY-negative subjects (0.16 nmol/L vs. 0.02 nmol/L; P = 0.02). After adjusting for age and diabetes duration, hsCRP levels were significantly lower in MODY-positive subjects (0.37 mg/L vs. 0.87 mg/L; P = 0.02). Random C-peptide level ≥0.15 nmol/L obtained at ≥6 months after diagnosis had 83% sensitivity for diagnosis of MODY with a negative predictive value of 96%. Receiver operating characteristic curves showed that area under the curve for random C-peptide (0.75) was significantly better than hsCRP (0.54), high-risk HLA DR3/4-DQB1*0302 (0.59), and high-risk HLA/random C-peptide combined (0.54; P = 0.03). Random C-peptide obtained at ≥6 months after diagnosis can be a useful biomarker to identify antibody-negative individuals who need further genetic testing for MODY, whereas hsCRP and HLA do not appear to improve this antibody/C-peptide-based approach.

  2. Utility of the Military Acute Concussion Evaluation as a screening tool for mild traumatic brain injury in a civilian trauma population.

    PubMed

    Stone, Melvin E; Safadjou, Saman; Farber, Benjamin; Velazco, Nerissa; Man, Jianliang; Reddy, Srinivas H; Todor, Roxanne; Teperman, Sheldon

    2015-07-01

    Mild traumatic brain injury (mTBI) constitutes 75% of more than 1.5 million traumatic brain injuries annually. There exists no consensus on point-of-care screening for mTBI. The Military Acute Concussion Evaluation (MACE) is a quick and easy test used by the US Army to screen for mTBI; however, its utility in civilian trauma is unclear. It has two parts: a history section and the Standardized Assessment of Concussion (SAC) score (0-30) previously validated in sports injury. As a performance improvement project, our institution sought to evaluate the MACE as a concussion screening tool that could be used by housestaff in a general civilian trauma population. From June 2013 to May 2014, patients 18 years to 65 years old with suspected concussion were given the MACE within 72 hours of admission to our urban Level I trauma center. Patients with a positive head computed tomography were excluded. Demographic data and MACE scores were recorded in prospect. Concussion was defined as loss of consciousness and/or posttraumatic amnesia; concussed patients were compared with those nonconcussed. Sensitivity and specificity for each respective MACE score were used to plot a receiver operating characteristic (ROC) curve. An ROC curve area of 0.8 was set as the benchmark for a good screening test to distinguish concussion from nonconcussion. There were 84 concussions and 30 nonconcussed patients. Both groups were similar; however, the concussion group had a lower mean MACE score than the nonconcussed patients. Data analysis demonstrated the sensitivity and specificity of a range of MACE scores used to generate an ROC curve area of only 0.65. The MACE showed a lower mean score for individuals with concussion, defined by loss of consciousness and/or posttraumatic amnesia. However, the ROC curve area of 0.65 highly suggests that MACE alone would be a poor screening test for mTBI in a general civilian trauma population. Diagnostic study, level II.

  3. Liquid Crystal Based Optical Phased Array for Steering Lasers

    DTIC Science & Technology

    2009-10-01

    profile into the liquid crystal cell, the first step is to characterize the LC cell’s OPD curve with respect to the ramped voltage by a simple one...corresponding voltage value on the OPD vs. 22 Voltage curve , the first entry voltage profile of a positive or negative micro-lens can be thereby...Fig. 2.6 Optical path delay (OPD) profile of ideal objective positive (blue curve ) and negative (green curve ) lens with 552 μm radius, no

  4. Comparison of two correlated ROC curves at a given specificity or sensitivity level

    PubMed Central

    Bantis, Leonidas E.; Feng, Ziding

    2017-01-01

    The receiver operating characteristic (ROC) curve is the most popular statistical tool for evaluating the discriminatory capability of a given continuous biomarker. The need to compare two correlated ROC curves arises when individuals are measured with two biomarkers, which induces paired and thus correlated measurements. Many researchers have focused on comparing two correlated ROC curves in terms of the area under the curve (AUC), which summarizes the overall performance of the marker. However, particular values of specificity may be of interest. We focus on comparing two correlated ROC curves at a given specificity level. We propose parametric approaches, transformations to normality, and nonparametric kernel-based approaches. Our methods can be straightforwardly extended for inference in terms of ROC−1(t). This is of particular interest for comparing the accuracy of two correlated biomarkers at a given sensitivity level. Extensions also involve inference for the AUC and accommodating covariates. We evaluate the robustness of our techniques through simulations, compare to other known approaches and present a real data application involving prostate cancer screening. PMID:27324068

  5. Comparison of radiologist performance with photon-counting full-field digital mammography to conventional full-field digital mammography.

    PubMed

    Cole, Elodia B; Toledano, Alicia Y; Lundqvist, Mats; Pisano, Etta D

    2012-08-01

    The purpose of this study was to assess the performance of a MicroDose photon-counting full-field digital mammography (PCM) system in comparison to full-field digital mammography (FFDM) for area under the receiver-operating characteristic (ROC) curve (AUC), sensitivity, specificity, and feature analysis of standard-view mammography for women presenting for screening mammography, diagnostic mammography, or breast biopsy. A total of 133 women were enrolled in this study at two European medical centers, with 67 women who had a pre-existing 10-36 months FFDM enrolled prospectively into the study and 66 women who underwent breast biopsy and had screening PCM and diagnostic FFDM, including standard craniocaudal and mediolateral oblique views of the breast with the lesion, enrolled retrospectively. The case mix consisted of 49 cancers, 17 biopsy-benign cases, and 67 normal cases. Sixteen radiologists participated in the reader study and interpreted all 133 cases in both conditions, separated by washout period of ≥4 weeks. ROC curve and free-response ROC curve analyses were performed for noninferiority of PCM compared to FFDM using a noninferiority margin Δ value of 0.10. Feature analysis of the 66 cases with lesions was conducted with all 16 readers at the conclusion of the blinded reads. Mean glandular dose was recorded for all cases. The AUC for PCM was 0.947 (95% confidence interval [CI], 0.920-0.974) and for FFDM was 0.931 (95% CI, 0.898-0.964). Sensitivity per case for PCM was 0.936 (95% CI, 0.897-0.976) and for FFDM was 0.908 (95% CI, 0.856-0.960). Specificity per case for PCM was 0.764 (95% CI, 0.688-0.841) and for FFDM was 0.749 (95% CI, 0.668-0.830). Free-response ROC curve figures of merit were 0.920 (95% CI, 0.881-0.959) and 0.903 (95% CI, 0.858-0.948) for PCM and FFDM, respectively. Sensitivity per lesion was 0.903 (95% CI, 0.846-0.960) and 0.883 (95% CI, 0.823-0.944) for PCM and FFDM, respectively. The average false-positive marks per image of noncancer cases were 0.265 (95% CI, 0.171-0.359) and 0.281 (95% CI, 0.188-0.374) for PCM and FFDM, respectively. Noninferiority P values for AUC, sensitivity (per case and per lesion), specificity, and average false-positive marks per image were all statistically significant (P < .001). The noninferiority P value for free-response ROC was <.025, from the 95% CI for the difference. Feature analysis resulted in PCM being preferred to FFDM by the readers for ≥70% of the cases. The average mean glandular dose for PCM was 0.74 mGy (95% CI, 0.722-0.759 mGy) and for FFDM was 1.23 mGy (95% CI, 1.199-1.262 mGy). In this study, radiologist performance with PCM was not inferior to that with conventional FFDM at an average 40% lower mean glandular dose. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  6. Myth and reality: practical test system for the measurement of anti-DNA antibodies in the diagnosis of systemic lupus erythematosus (SLE).

    PubMed

    McCloskey, Laura J; Christner, Paul; Jacobs-Kosmin, Dana; Jaskowski, Troy D; Hill, Harry R; Lakos, Gabriella; Teodorescu, Marius

    2010-01-01

    The myth persists that only the labor intensive Farr radioimmunoassay and Crithidia luciliae immunofluorescence (CL-IFA) are systemic lupus erythematosus (SLE)-specific tests. We compared them to ELISA with bacteriophage lambda DNA (EL-dsDNA) and denatured calf thymus DNA (EL-ssDNA). By percentile ranking, the specificity cut-off level was set both out of clinical context (SOCC) on 100 blood bank donors, and in clinical context (SICC) on 100 patients with either rheumatoid arthritis or scleroderma (50/50). Clinical sensitivity was calculated on 100 random SLE patients. At 95% SICC, the sensitivity of Farr, CL-IFA, EL-dsDNA, and EL-ssDNA was similar (95%CI): 76% (66-84), 76% (66-84), 63% (53-72), and 75% (65-83), respectively; 87% of the patients were positive by at least one method and 55%by all methods. At 99% SICC, the sensitivity was also similar (95% CI): 57% (47-67), 47% (37-57), 58% (47-67), and 43% (33-53), respectively. The areas under ROC curve were similar (95% CI) when patients were used as controls for specificity. At 99% SOCC, EL-ssDNA identified 89% positive, 2 negative but positive by another method at 95% SICC, and 9 negative (i.e. 89/2/9), followed by CL-IFA (80/6/14), Farr (76/12/12), and EL-dsDNA (64/23/13). Thus, at relatively low cost and easy automation, under the same conditions of specificity, the two ELISA tests combined were at least as good, if not superior, to CL-IFA or Farr: they showed similar clinical sensitivity and also identified more patients with anti-DNA antibodies. (c) 2010 Wiley-Liss, Inc.

  7. Quantivirus® HPV E6/E7 RNA 3.0 assay (bDNA) is as sensitive, but less specific than Hybrid Capture 2 test.

    PubMed

    Shen, Yong; Gong, Jiaomei; He, Yanxia; Cheng, Guomei; Okunieff, Paul; Li, Xiaofu

    2013-02-01

    Human papillomavirus (HPV) infection is the primary cause of cervical cancer. The Quantivirus(®) HPV E6/E7 RNA 3.0 assay (DiaCarta, CA, USA) detects E6/E7 mRNA of 13 high risk subtypes and 6 low risk subtypes. Cervical specimens collected in PreservCyt were processed for HPV detection. Cervical biopsies were taken only from those women with abnormal colposcopy. 200 out of 272 (73.5%) cases were mRNA positive. The percentage of HPV E6/E7 mRNA positive samples increases with the severity of the cytological diagnosis, but not in histological diagnosis. In 146 patients with both tests, the E6/E7 mRNA assay had significant higher positivity rate than the Hybrid Capture 2 assay (75.3% versus 62.3%). The HPV mRNA assay and the HC2 assay had the same sensitivity of high grade cervical intraepithelial neoplasia (CIN 2+), 82.4% (14/17) (95% confidence interval [CI], 64.3, 100). However, the specificity of CIN 2+ for the HPV mRNA assay was significantly lower than HC2 assay. Receiver operating characteristic curve analysis was used to compare the diagnostic performance of the E6/E7 mRNA and HC2. E6/E7 mRNA achieved 58.8% sensitivity with 74.1% specificity, HC2, achieved 47.1% sensitivity with 70.7% specificity. The overall performance of HPV E6/E7 mRNA assay for detecting CIN 2+ was lower than HC2. This study does not support the use of this assay in screening for cervical cancer prevention alone. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Diagnosis of subclinical amniotic fluid infection prior to rescue cerclage using gram stain and glucose tests: an individual patient meta-analysis.

    PubMed

    Lisonkova, Sarka; Sabr, Yasser; Joseph, K S

    2014-02-01

    Microbial invasion of the amniotic cavity (MIAC) can affect outcomes following rescue cerclage. We carried out a study to compare the diagnostic performance of the Gram stain and glucose tests for detecting subclinical MIAC. We used individual-level data from published studies on Gram stain, glucose, and amniotic fluid culture among women with preterm labour. We calculated the sensitivity, specificity, area under the curve (AUC) and other indices, with amniotic fluid culture results used as the gold standard. The probability of infection using both tests as predictors was also estimated using logistic regression. The rate of culture-confirmed MIAC was 11.8% (34 of 288 women). The Gram stain test yielded a sensitivity of 65% (95% CI 46% to 78%) and a specificity of 99% (95% CI 98% to 100%). A positive Gram stain or glucose test had a sensitivity of 88% (95% CI 72% to 96%) and a specificity of 87% (95% CI 82% to 90%), while a positive Gram stain and a positive glucose test had a sensitivity of 62% (95% CI 44% to 77%) and a specificity of 100% (95% CI 98% to 100%). The AUC for the tests were Gram stain 0.82 (95% CI 0.74 to 0.90), glucose 0.86 (95% CI 0.80 to 0.93), and combined Gram stain and glucose 0.92 (95% CI 0.86 to 0.98). Using the tests, singly or in combination, provided greater clinically important calibration, risk-stratification, and classification accuracy than using no tests. Amniotic fluid Gram stain and/or glucose testing provides substantially improved performance for the diagnosis of subclinical MIAC compared with no testing.

  9. Selective parathyroid venous sampling in primary hyperparathyroidism: A systematic review and meta-analysis.

    PubMed

    Ibraheem, Kareem; Toraih, Eman A; Haddad, Antoine B; Farag, Mahmoud; Randolph, Gregory W; Kandil, Emad

    2018-05-14

    Minimally invasive parathyroidectomy requires accurate preoperative localization techniques. There is considerable controversy about the effectiveness of selective parathyroid venous sampling (sPVS) in primary hyperparathyroidism (PHPT) patients. The aim of this meta-analysis is to examine the diagnostic accuracy of sPVS as a preoperative localization modality in PHPT. Studies evaluating the diagnostic accuracy of sPVS for PHPT were electronically searched in the PubMed, EMBASE, Web of Science, and Cochrane Controlled Trials Register databases. Two independent authors reviewed the studies, and revised quality assessment of diagnostic accuracy study tool was used for the quality assessment. Study heterogeneity and pooled estimates were calculated. Two hundred and two unique studies were identified. Of those, 12 studies were included in the meta-analysis. Pooled sensitivity, specificity, and positive likelihood ratio (PLR) of sPVS were 74%, 41%, and 1.55, respectively. The area-under-the-receiver operating characteristic curve was 0.684, indicating an average discriminatory ability of sPVS. On comparison between sPVS and noninvasive imaging modalities, sensitivity, PLR, and positive posttest probability were significantly higher in sPVS compared to noninvasive imaging modalities. Interestingly, super-selective venous sampling had the highest sensitivity, accuracy, and positive posttest probability compared to other parathyroid venous sampling techniques. This is the first meta-analysis to examine the accuracy of sPVS in PHPT. sPVS had higher pooled sensitivity when compared to noninvasive modalities in revision parathyroid surgery. However, the invasiveness of this technique does not favor its routine use for preoperative localization. Super-selective venous sampling was the most accurate among all other parathyroid venous sampling techniques. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  11. The concurrent validity of the Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale in adolescent patients in an urban federally qualified health center.

    PubMed

    Kelly, Sharon M; O'Grady, Kevin E; Gryczynski, Jan; Mitchell, Shannon Gwin; Kirk, Arethusa; Schwartz, Robert P

    2017-01-01

    The Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale has been validated with high school students, adolescents with criminal justice involvement, and adolescent substance use treatment samples using the Diagnostic and Statistical Manual of Mental Disorders (DSM)-III-R and DSM-IV. This study examines the concurrent validity of the POSIT's standard 17-item substance use/abuse subscale and a revised, shorter 11-item version using DSM-5 substance use disorder diagnoses. Adolescents (N = 525; 93% African American, 55% female) 12-17 years of age awaiting primary care appointments at a Federally Qualified Health Center in Baltimore, Maryland completed the 17-item POSIT substance use/abuse subscale and items from a modified World Mental Health Composite International Diagnostic Interview corresponding to DSM-5 alcohol use disorder (AUD) and cannabis use disorder (CUD). Receiver operating characteristic curves, sensitivities, and specificities were examined with DSM-5 AUD, CUD, and a diagnosis of either or both disorders for the standard and revised subscales using risk cutoffs of either 1 or 2 POSIT "yes" responses. For the 17-item subscale, sensitivities were generally high using either cutoff (range: 0.79-1.00), although a cutoff of 1 was superior (sensitivities were 1.00 for AUD, CUD, and for either disorder). Specificities were also high using either cutoff (range: 0.81-0.95) but were higher using a cutoff of 2. For the 11-item subscale, a cutoff of 1 yielded higher sensitivities than a cutoff of 2 (ranges for 1 and 2: 0.96-1.00 and 0.79-0.86, respectively). Specificities for this subscale were higher using a cutoff of 2 (ranges for 1 and 2: 0.82-0.89 and 0.89-0.96, respectively). Findings suggest that the POSIT's substance use/abuse subscale is a potentially useful tool for screening adolescents in primary care for AUD or CUD using a cutoff of 1 or 2. The briefer, revised subscale may be preferable to the standard subscale in busy pediatric practices.

  12. Validation of an Immunodiagnostic Assay for Detection of 13 Streptococcus pneumoniae Serotype-Specific Polysaccharides in Human Urine

    PubMed Central

    Huijts, Susanne M.; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C.; Bonten, Marc J. M.; Jansen, Kathrin U.

    2012-01-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults. PMID:22675155

  13. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    PubMed

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  14. Effectiveness of real-time polymerase chain reaction assay for the detection of Mycobacterium tuberculosis in pathological samples: a systematic review and meta-analysis.

    PubMed

    Babafemi, Emmanuel O; Cherian, Benny P; Banting, Lee; Mills, Graham A; Ngianga, Kandala

    2017-10-25

    Rapid and accurate diagnosis of tuberculosis (TB) is key to manage the disease and to control and prevent its transmission. Many established diagnostic methods suffer from low sensitivity or delay of timely results and are inadequate for rapid detection of Mycobacterium tuberculosis (MTB) in pulmonary and extra-pulmonary clinical samples. This study examined whether a real-time polymerase chain reaction (RT-PCR) assay, with a turn-a-round time of 2 h, would prove effective for routine detection of MTB by clinical microbiology laboratories. A systematic literature search was performed for publications in any language on the detection of MTB in pathological samples by RT-PCR assay. The following sources were used MEDLINE via PubMed, EMBASE, BIOSIS Citation Index, Web of Science, SCOPUS, ISI Web of Knowledge and Cochrane Infectious Diseases Group Specialised Register, grey literature, World Health Organization and Centres for Disease Control and Prevention websites. Forty-six studies met set inclusion criteria. Generated pooled summary estimates (95% CIs) were calculated for overall accuracy and bivariate meta-regression model was used for meta-analysis. Summary estimates for pulmonary TB (31 studies) were as follows: sensitivity 0.82 (95% CI 0.81-0.83), specificity 0.99 (95% CI 0.99-0.99), positive likelihood ratio 43.00 (28.23-64.81), negative likelihood ratio 0.16 (0.12-0.20), diagnostic odds ratio 324.26 (95% CI 189.08-556.09) and area under curve 0.99. Summary estimates for extra-pulmonary TB (25 studies) were as follows: sensitivity 0.70 (95% CI 0.67-0.72), specificity 0.99 (95% CI 0.99-0.99), positive likelihood ratio 29.82 (17.86-49.78), negative likelihood ratio 0.33 (0.26-0.42), diagnostic odds ratio 125.20 (95% CI 65.75-238.36) and area under curve 0.96. RT-PCR assay demonstrated a high degree of sensitivity for pulmonary TB and good sensitivity for extra-pulmonary TB. It indicated a high degree of specificity for ruling in TB infection from sampling regimes. This was acceptable, but may better as a rule out add-on diagnostic test. RT-PCR assays demonstrate both a high degree of sensitivity in pulmonary samples and rapidity of detection of TB which is an important factor in achieving effective global control and for patient management in terms of initiating early and appropriate anti-tubercular therapy. PROSPERO CRD42015027534 .

  15. Defining the learning curve for multiparametric magnetic resonance imaging (MRI) of the prostate using MRI-transrectal ultrasonography (TRUS) fusion-guided transperineal prostate biopsies as a validation tool.

    PubMed

    Gaziev, Gabriele; Wadhwa, Karan; Barrett, Tristan; Koo, Brendan C; Gallagher, Ferdia A; Serrao, Eva; Frey, Julia; Seidenader, Jonas; Carmona, Lina; Warren, Anne; Gnanapragasam, Vincent; Doble, Andrew; Kastner, Christof

    2016-01-01

    To determine the accuracy of multiparametric magnetic resonance imaging (mpMRI) during the learning curve of radiologists using MRI targeted, transrectal ultrasonography (TRUS) guided transperineal fusion biopsy (MTTP) for validation. Prospective data on 340 men who underwent mpMRI (T2-weighted and diffusion-weighted MRI) followed by MTTP prostate biopsy, was collected according to Ginsburg Study Group and Standards for Reporting of Diagnostic Accuracy standards. MRI data were reported by two experienced radiologists and scored on a Likert scale. Biopsies were performed by consultant urologists not 'blinded' to the MRI result and men had both targeted and systematic sector biopsies, which were reviewed by a dedicated uropathologist. The cohorts were divided into groups representing five consecutive time intervals in the study. Sensitivity and specificity of positive MRI reports, prostate cancer detection by positive MRI, distribution of significant Gleason score and negative MRI with false negative for prostate cancer were calculated. Data were sequentially analysed and the learning curve was determined by comparing the first and last group. We detected a positive mpMRI in 64 patients from Group A (91%) and 52 patients from Group E (74%). The prostate cancer detection rate on mpMRI increased from 42% (27/64) in Group A to 81% (42/52) in Group E (P < 0.001). The prostate cancer detection rate by targeted biopsy increased from 27% (17/64) in Group A to 63% (33/52) in Group E (P < 0.001). The negative predictive value of MRI for significant cancer (>Gleason 3+3) was 88.9% in Group E compared with 66.6% in Group A. We demonstrate an improvement in detection of prostate cancer for MRI reporting over time, suggesting a learning curve for the technique. With an improved negative predictive value for significant cancer, decision for biopsy should be based on patient/surgeon factors and risk attributes alongside the MRI findings. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  16. Diagnostic value of highly-sensitive chimerism analysis after allogeneic stem cell transplantation.

    PubMed

    Sellmann, Lea; Rabe, Kim; Bünting, Ivonne; Dammann, Elke; Göhring, Gudrun; Ganser, Arnold; Stadler, Michael; Weissinger, Eva M; Hambach, Lothar

    2018-05-02

    Conventional analysis of host chimerism (HC) frequently fails to detect relapse before its clinical manifestation in patients with hematological malignancies after allogeneic stem cell transplantation (allo-SCT). Quantitative PCR (qPCR)-based highly-sensitive chimerism analysis extends the detection limit of conventional (short tandem repeats-based) chimerism analysis from 1 to 0.01% host cells in whole blood. To date, the diagnostic value of highly-sensitive chimerism analysis is hardly defined. Here, we applied qPCR-based chimerism analysis to 901 blood samples of 71 out-patients with hematological malignancies after allo-SCT. Receiver operating characteristics (ROC) curves were calculated for absolute HC values and for the increments of HC before relapse. Using the best cut-offs, relapse was detected with sensitivities of 74 or 85% and specificities of 69 or 75%, respectively. Positive predictive values (PPVs) were only 12 or 18%, but the respective negative predictive values were 98 or 99%. Relapse was detected median 38 or 45 days prior to clinical diagnosis, respectively. Considering also durations of steadily increasing HC of more than 28 days improved PPVs to more than 28 or 59%, respectively. Overall, highly-sensitive chimerism analysis excludes relapses with high certainty and predicts relapses with high sensitivity and specificity more than a month prior to clinical diagnosis.

  17. Differential diagnosis of benign and malignant breast masses using diffusion-weighted magnetic resonance imaging.

    PubMed

    Min, Qinghua; Shao, Kangwei; Zhai, Lulan; Liu, Wei; Zhu, Caisong; Yuan, Lixin; Yang, Jun

    2015-02-07

    Diffusion-weighted magnetic resonance imaging (DW-MRI) is different from conventional diagnostic methods and has the potential to delineate the microscopic anatomy of a target tissue or organ. The purpose of our study was to evaluate the value of DW-MRI in the diagnosis of benign and malignant breast masses, which would help the clinical surgeon to decide the scope and pattern of operation. A total of 52 female patients with palpable solid breast masses received breast MRI scans using routine sequences, dynamic contrast-enhanced imaging, and diffusion-weighted echo-planar imaging at b values of 400, 600, and 800 s/mm(2), respectively. Two regions of interest (ROIs) were plotted, with a smaller ROI for the highest signal and a larger ROI for the overall lesion. Apparent diffusion coefficient (ADC) values were calculated at three different b values for all detectable lesions and from two different ROIs. The sensitivity, specificity, positive predictive value, and positive likelihood ratio of DW-MRI were determined for comparison with histological results. A total of 49 (49/52, 94.2%) lesions were detected using DW-MRI, including 20 benign lesions (two lesions detected in the same patient) and 29 malignant lesions. Benign lesion had a higher mean ADC value than their malignant counterparts, regardless of b value. According to the receiver operating characteristic (ROC) curve, the smaller-range ROI was more effective in differentiation between benign and malignant lesions. The area under the ROC curve was the largest at a b value of 800 s/mm(2). With a threshold ADC value at 1.23 × 10(-3) mm(2)/s, DW-MRI achieved a sensitivity of 82.8%, specificity of 90.0%, positive predictive value of 92.3%, and positive likelihood ratio of 8.3 for differentiating benign and malignant lesions. DW-MRI is an accurate diagnostic tool for differentiation between benign and malignant breast lesions, with an optimal b value of 800 s/mm(2). A smaller-range ROI focusing on the highest signal has a better differential value.

  18. Angiotensin-converting Enzyme as a Predictor of Extrathoracic Involvement of Sarcoidosis.

    PubMed

    Yasar, Zehra; Özgül, Mehmet Akif; Cetinkaya, Erdoğan; Kargi, Aysel; Gül, Şule; Talay, Fahrettin; Tanriverdi, Elif; Dincer, H Erhan

    2016-01-18

    Sarcoidosis is a multisystem disease, with extrathoracic involvement occurring in 25-50% of patients. Multi-organ involvement is often associated with a more chronic and severe course. The value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in diagnosing extrathoracic involvement in sarcoidosis has been demonstrated; however, because of the radiation dose and high cost, indications for its use must be well defined. Angiotensin-converting enzyme (ACE) is produced by active granuloma cells; thus, serum ACE (sACE) levels may reflect the total granuloma load. In this retrospective study, we evaluated the diagnostic value of sACE in the detection of extrathoracic involvement in sarcoidosis. 43 patients with biopsy-proven sarcoidosis underwent FDG-PET/CT during the initial workup. Positive findings were classified as thoracic and/or extrathoracic. The diagnostic value of sACE was estimated using sensitivity, specificity, and area under the receiver operating characteristic curves (AUCs). Of the 43 patients studied, 17 (39.7%) had extrathoracic involvement. In this group, sACE values were higher than in patients without extrathoracic involvement (331 vs. 150, p=0.002) and correlated positively with extrathoracic involvement (R:0.532 p=0.02). Receiver operator characteristic curve analysis revealed an AUC of 0.816 [95% confidence interval: 0.669-0.963, p=0.002], 70.6% sensitivity and 80% specificity at the sACE cut-off value. In sarcoidosis, extrathoracic involvement may be life threatening or indicative of poor outcome. sACE levels are easily determined and may predict extrathoracic involvement. In patients with sarcoidosis, sACE levels can be used to better define those who would benefit from FDG-PET/CT examination to detect extrathoracic involvement.

  19. Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.

    PubMed

    Wu, Huijuan; de Boer, Johannes F; Chen, Teresa C

    2012-05-01

    To determine the diagnostic capability of spectral-domain optical coherence tomography in glaucoma patients with visual field defects. Prospective, cross-sectional study. Participants were recruited from a university hospital clinic. One eye of 85 normal subjects and 61 glaucoma patients with average visual field mean deviation of -9.61 ± 8.76 dB was selected randomly for the study. A subgroup of the glaucoma patients with early visual field defects was calculated separately. Spectralis optical coherence tomography (Heidelberg Engineering, Inc) circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Overall RNFL thickness had the highest area under the receiver operating characteristic curve values: 0.952 for all patients and 0.895 for the early glaucoma subgroup. For all patients, the highest sensitivity (98.4%; 95% confidence interval, 96.3% to 100%) was achieved by using 2 criteria: ≥ 1 RNFL sectors being abnormal at the < 5% level and overall classification of borderline or outside normal limits, with specificities of 88.9% (95% confidence interval, 84.0% to 94.0%) and 87.1% (95% confidence interval, 81.6% to 92.5%), respectively, for these 2 criteria. Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral-domain optical coherence tomography were good for early perimetric glaucoma and were excellent for moderately advanced perimetric glaucoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Can non‐clinical repolarization assays predict the results of clinical thorough QT studies? Results from a research consortium

    PubMed Central

    Park, Eunjung; Gintant, Gary A; Bi, Daoqin; Kozeli, Devi; Pettit, Syril D; Skinner, Matthew; Willard, James; Wisialowski, Todd; Koerner, John; Valentin, Jean‐Pierre

    2018-01-01

    Background and Purpose Translation of non‐clinical markers of delayed ventricular repolarization to clinical prolongation of the QT interval corrected for heart rate (QTc) (a biomarker for torsades de pointes proarrhythmia) remains an issue in drug discovery and regulatory evaluations. We retrospectively analysed 150 drug applications in a US Food and Drug Administration database to determine the utility of established non‐clinical in vitro IKr current human ether‐à‐go‐go‐related gene (hERG), action potential duration (APD) and in vivo (QTc) repolarization assays to detect and predict clinical QTc prolongation. Experimental Approach The predictive performance of three non‐clinical assays was compared with clinical thorough QT study outcomes based on free clinical plasma drug concentrations using sensitivity and specificity, receiver operating characteristic (ROC) curves, positive (PPVs) and negative predictive values (NPVs) and likelihood ratios (LRs). Key Results Non‐clinical assays demonstrated robust specificity (high true negative rate) but poor sensitivity (low true positive rate) for clinical QTc prolongation at low‐intermediate (1×–30×) clinical exposure multiples. The QTc assay provided the most robust PPVs and NPVs (ability to predict clinical QTc prolongation). ROC curves (overall test accuracy) and LRs (ability to influence post‐test probabilities) demonstrated overall marginal performance for hERG and QTc assays (best at 30× exposures), while the APD assay demonstrated minimal value. Conclusions and Implications The predictive value of hERG, APD and QTc assays varies, with drug concentrations strongly affecting translational performance. While useful in guiding preclinical candidates without clinical QT prolongation, hERG and QTc repolarization assays provide greater value compared with the APD assay. PMID:29181850

  1. Detection of Obstructive Coronary Artery Disease Using Peak Systolic Global Longitudinal Strain Derived by Two-Dimensional Speckle-Tracking: A Systematic Review and Meta-Analysis.

    PubMed

    Liou, Kevin; Negishi, Kazuaki; Ho, Suyen; Russell, Elizabeth A; Cranney, Greg; Ooi, Sze-Yuan

    2016-08-01

    Global longitudinal strain (GLS) is well validated and has important applications in contemporary clinical practice. The aim of this analysis was to evaluate the accuracy of resting peak GLS in the diagnosis of obstructive coronary artery disease (CAD). A systematic literature search was performed through July 2015 using four databases. Data were extracted independently by two authors and correlated before analyses. Using a random-effect model, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary area under the curve for GLS were estimated with their respective 95% CIs. Screening of 1,669 articles yielded 10 studies with 1,385 patients appropriate for inclusion in the analysis. The mean age and left ventricular ejection fraction were 59.9 years and 61.1%. On the whole, 54.9% and 20.9% of the patients had hypertension and diabetes, respectively. Overall, abnormal GLS detected moderate to severe CAD with a pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 74.4%, 72.1%, 2.9, and 0.35 respectively. The area under the curve and diagnostic odds ratio were 0.81 and 8.5. The mean values of GLS for those with and without CAD were -16.5% (95% CI, -15.8% to -17.3%) and -19.7% (95% CI, -18.8% to -20.7%), respectively. Subgroup analyses for patients with severe CAD and normal left ventricular ejection fractions yielded similar results. Current evidence supports the use of GLS in the detection of moderate to severe obstructive CAD in symptomatic patients. GLS may complement existing diagnostic algorithms and act as an early adjunctive marker of cardiac ischemia. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  2. Clinical performance of a new point-of-care cardiac troponin I test.

    PubMed

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  3. Feasibility of α-fetoprotein as a diagnostic tool for hepatocellular carcinoma in Korea

    PubMed Central

    Ahn, Dae Geon; Kim, Hyung Joon; Kang, Hyun; Lee, Hyun Woong; Bae, Si Hyun; Lee, Joon Hyoek; Paik, Yong Han; Lee, June Sung

    2016-01-01

    Background/Aims: The aim of this study was to evaluate the feasibility of α-fetoprotein (AFP) as a diagnostic tool for hepatocellular carcinoma (HCC) in Korean patients. Methods: We retrospectively reviewed the medical records of HCC and cirrhosis patients at three hospitals. For each HCC patient, a cirrhosis patient matched for age, sex, etiology, and Child-Pugh classification was selected by simple random sampling. The performance of AFP in the diagnosis of HCC was determined using receiver operating characteristic curve analysis. Results: A total of 732 patients with HCC or cirrhosis were selected for each case and the control groups. The mean age was 54 years, and 72.4% of patients were male. The mean serum AFP levels in the HCC group and cirrhosis group were 3,315.6 and 117.2 ng/mL, respectively (p < 0.001). The area under the receiver operating characteristic curve for all HCC patients was 0.757. The sensitivity, specificity, and positive predictive value of AFP was 50.55%, 87.70%, and 80.43%, respectively, at a cut-off of 20 ng/mL; 37.70%, 95.90%, and 90.20%, respectively, at a cut-off of 100 ng/mL, and 30.05%, 97.27%, and 91.67%, respectively, at a cut-off of 200 ng/mL. A cut-off of 100 ng/mL was more sensitive than one of 200 ng/mL with equivalent specificity and positive predictive value. Conclusions: The cut-off AFP value for early-stage HCC was 17.4 ng/mL. Our study cautiously suggests that AFP has a role in the diagnosis of HCC, and that the appropriate value of AFP for the diagnosis of HCC may be 100 ng/mL rather than 200 ng/mL. PMID:26767857

  4. Feasibility of α-fetoprotein as a diagnostic tool for hepatocellular carcinoma in Korea.

    PubMed

    Ahn, Dae Geon; Kim, Hyung Joon; Kang, Hyun; Lee, Hyun Woong; Bae, Si Hyun; Lee, Joon Hyoek; Paik, Yong Han; Lee, June Sung

    2016-01-01

    The aim of this study was to evaluate the feasibility of α-fetoprotein (AFP) as a diagnostic tool for hepatocellular carcinoma (HCC) in Korean patients. We retrospectively reviewed the medical records of HCC and cirrhosis patients at three hospitals. For each HCC patient, a cirrhosis patient matched for age, sex, etiology, and Child-Pugh classification was selected by simple random sampling. The performance of AFP in the diagnosis of HCC was determined using receiver operating characteristic curve analysis. A total of 732 patients with HCC or cirrhosis were selected for each case and the control groups. The mean age was 54 years, and 72.4% of patients were male. The mean serum AFP levels in the HCC group and cirrhosis group were 3,315.6 and 117.2 ng/mL, respectively (p < 0.001). The area under the receiver operating characteristic curve for all HCC patients was 0.757. The sensitivity, specificity, and positive predictive value of AFP was 50.55%, 87.70%, and 80.43%, respectively, at a cut-off of 20 ng/mL; 37.70%, 95.90%, and 90.20%, respectively, at a cut-off of 100 ng/mL, and 30.05%, 97.27%, and 91.67%, respectively, at a cut-off of 200 ng/mL. A cut-off of 100 ng/mL was more sensitive than one of 200 ng/mL with equivalent specificity and positive predictive value. The cut-off AFP value for early-stage HCC was 17.4 ng/mL. Our study cautiously suggests that AFP has a role in the diagnosis of HCC, and that the appropriate value of AFP for the diagnosis of HCC may be 100 ng/mL rather than 200 ng/mL.

  5. Efficacy of the alcohol use disorders identification test as a screening tool for hazardous alcohol intake and related disorders in primary care: a validity study.

    PubMed Central

    Piccinelli, M.; Tessari, E.; Bortolomasi, M.; Piasere, O.; Semenzin, M.; Garzotto, N.; Tansella, M.

    1997-01-01

    OBJECTIVE: To determine the properties of the alcohol use disorders identification test in screening primary care attenders for alcohol problems. DESIGN: A validity study among consecutive primary care attenders aged 18-65 years. Every third subject completed the alcohol use disorders identification test (a 10 item self report questionnaire on alcohol intake and related problems) and was interviewed by an investigator with the composite international diagnostic interview alcohol use module (a standardised interview for the independent assessment of alcohol intake and related disorders). SETTING: 10 primary care clinics in Verona, north eastern Italy. PATIENTS: 500 subjects were approached and 482 (96.4%) completed evaluation. RESULTS: When the alcohol use disorders identification test was used to detect subjects with alcohol problems the area under the receiver operating characteristic curve was 0.95. The cut off score of 5 was associated with a sensitivity of 0.84, a specificity of 0.90, and a positive predictive value of 0.60. The screening ability of the total score derived from summing the responses to the five items minimising the probability of misclassification between subjects with and without alcohol problems provided an area under the receiver operating characteristic curve of 0.93. A score of 5 or more on the five items was associated with a sensitivity of 0.79, a specificity of 0.95, and a positive predictive value of 0.73. CONCLUSIONS: The alcohol use disorders identification test performs well in detecting subjects with formal alcohol disorders and those with hazardous alcohol intake. Using five of the 10 items on the questionnaire gives reasonable accuracy, and these are recommended as questions of choice to screen patients for alcohol problems. PMID:9040389

  6. The CURB65 pneumonia severity score outperforms generic sepsis and early warning scores in predicting mortality in community‐acquired pneumonia

    PubMed Central

    Barlow, Gavin; Nathwani, Dilip; Davey, Peter

    2007-01-01

    Background The performance of CURB65 in predicting mortality in community‐acquired pneumonia (CAP) has been tested in two large observational studies. However, it has not been tested against generic sepsis and early warning scores, which are increasingly being advocated for identification of high‐risk patients in acute medical wards. Method A retrospective analysis was performed of data prospectively collected for a CAP quality improvement study. The ability to stratify mortality and performance characteristics (sensitivity, specificity, positive predictive value, negative predictive value and area under the receiver operating curve) were calculated for stratifications of CURB65, CRB65, the systemic inflammatory response syndrome (SIRS) criteria and the standardised early warning score (SEWS). Results 419 patients were included in the main analysis with a median age of 74 years (men = 47%). CURB65 and CRB65 stratified mortality in a more clinically useful way and had more favourable operating characteristics than SIRS or SEWS; for example, mortality in low‐risk patients was 2% when defined by CURB65, but 9% when defined by SEWS and 11–17% when defined by variations of the SIRS criteria. The sensitivity, specificity, positive predictive value and negative predictive value of CURB65 was 71%, 69%, 35% and 91%, respectively, compared with 62%, 73%, 35% and 89% for the best performing version of SIRS and 52%, 67%, 27% and 86% for SEWS. CURB65 had the greatest area under the receiver operating curve (0.78 v 0.73 for CRB65, 0.68 for SIRS and 0.64 for SEWS). Conclusions CURB65 should not be supplanted by SIRS or SEWS for initial prognostic assessment in CAP. Further research to identify better generic prognostic tools is required. PMID:16928720

  7. Using Precept-Assist® to predict performance on the American Board of Family Medicine In-Training Examination.

    PubMed

    Post, Robert E; Jamena, Gemma P; Gamble, James D

    2014-09-01

    Precept-Assist® (PA) is a computer-based program developed by the Virtua Family Medicine Residency where residents receive a score on a Likert-type scale from an attending for each precept based on their knowledge base. The purpose of this study was to attempt to validate this program for precepting family medicine residents. This was a validation study. PA and American Board of Family Medicine (ABFM) In-Training Exam (ITE) scores for all residents from a community-based family medicine residency between the years 2002 and 2011 were included (n=216). Pearson correlation coefficients were calculated between PA scores for the second quarter of the academic year (October 1 to December 31) and scores on the ITE. An ROC curve was also created to determine sensitivity and specificity for various PA scores in predicting residents scoring 500 or above on the ITE. The PA mean (SD) score was 5.18 (0.84) and the ITE mean (SD) score was 425.1 (87.6). The Pearson correlation coefficient between PA and ITE scores was 0.55, which is a moderately positive correlation. The AUC of the ROC curve was 0.783 (95% CI 0.704-0.859). A PA score of 5.5 (between the level of a PGY-2 and PGY-3) was 72% sensitive and 77% specific for scoring 500 or above on the ITE with a positive LR of 3.12. There is a significant correlation between PA scores and ABFM In-Training Exam scores. PA is a valid screening tool that can be used as a predictor for future performance in Family Medicine In-Training exams.

  8. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    PubMed

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. ACTH after 15 min distinguishes between Cushing's disease and ectopic Cushing's syndrome: a proposal for a short and simple CRH test.

    PubMed

    Ritzel, Katrin; Beuschlein, Felix; Berr, Christina; Osswald, Andrea; Reisch, Nicole; Bidlingmaier, Martin; Schneider, Harald; Honegger, Jürgen; Geyer, Lucas L; Schopohl, Jochen; Reincke, Martin

    2015-08-01

    The aim of the present study was to validate criteria of corticotropin-releasing hormone (CRH) stimulation and 8 mg dexamethasone suppression (high-dose dexamethasone suppression, HDDS) to distinguish the etiology of ACTH-dependent Cushing's syndrome. We retrospectively analyzed cortisol and ACTH after the injection of 100 μg human CRH in confirmed Cushing's disease (CD, n=78) and confirmed ectopic Cushing's syndrome (ECS, n=18). Cortisol and ACTH increase (in percentage above basal (%B)) at each time point, maximal increase (Δmax %B), and area under the curve (AUC %B) were analyzed using receiver operator characteristics (ROC) curve analyses. Cortisol suppression (%B) after 8 mg of dexamethasone was evaluated as a supplementary criterion. An increase in ACTH of ≥ 43%B at 15 min after CRH was the strongest predictor of CD, with a positive likelihood ratio of 14.0, a sensitivity of 83%, a specificity of 94%, a positive predictive value of 98% and a negative predictive value of 58%. All of the other criteria of stimulated ACTH and cortisol levels were not superior in predicting CD in response to CRH injection. The addition of cortisol suppression by dexamethasone did not increase the discriminatory power. However, the combination of a positive ACTH response at 15 min and a positive HDDS test excluded ECS in all cases. The present findings support the use of plasma ACTH levels 15 min after the injection of human CRH as a response criterion for distinguishing between CD and ECS. The addition of the HDDS test is helpful for excluding ECS when both tests are positive. © 2015 European Society of Endocrinology.

  10. Colonic polyps: application value of computer-aided detection in computed tomographic colonography.

    PubMed

    Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan

    2011-02-01

    Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.

  11. Accuracy of the QuantiFERON-TB Gold in Tube for diagnosing tuberculosis in a young pediatric population previously vaccinated with Bacille Calmette-Guérin

    PubMed Central

    Vallada, Marcelo Genofre; Okay, Thelma Suely; Del Negro, Gilda Maria B.; Antonio, Claudio Amaral; Yamamoto, Lidia; Ramos, Sonia Regina T. S.

    2014-01-01

    Objective: To evaluate the accuracy of an interferongamma release assay (QuantiFERON-TB Gold in Tube) for diagnosing Mycobacterium tuberculosis infection in a young pediatric population. Methods: 195 children previously vaccinated with BCG were evaluated, being 184 healthy individuals with no clinical or epidemiological evidence of mycobacterial infection, and 11 with Mycobacterium tuberculosis infection, according to clinical, radiological, and laboratory parameters. A blood sample was obtained from each child and processed according to the manufacturer's instructions. The assay performance was evaluated by a Receiver Operating Characteristic (ROC) curve. Results: In the group of 184 non-infected children, 130 (70.6%) were under the age of four years (mean age of 35 months). In this group, 177 children (96.2%) had negative test results, six (3.2%) had indeterminate results, and one (0.5%) had a positive result. In the group of 11 infected children, the mean age was 58.5 months, and two of them (18%) had negative results. The ROC curve had an area under the curve of 0.88 (95%CI 0.82-0.92; p<0.001), disclosing a predictive positive value of 81.8% for the test (95%CI 46.3-97.4). The assay sensitivity was 81.8% (95%CI 48.2-97.2) and the specificity was 98.8% (95%CI 96-99.8). Conclusions: In the present study, the QuantiFERON-TB Gold in Tube performance for diagnosing M. tuberculosis infection was appropriate in a young pediatric population. PMID:24676183

  12. Radiation damage and sensitization effects on thermoluminescence of LiF:Mg,Ti (TLD-700)

    NASA Astrophysics Data System (ADS)

    Farag, M. A.; Sadek, A. M.; Shousha, Hany. A.; El-Hagg, A. A.; Atta, M. R.; Kitis, G.

    2017-09-01

    The radiation damage effects and enhancement the thermoluminescence (TL) efficiency of LiF:Mg,Ti (TLD-700)dosimeters via sensitization method were discussed. Attempts to eliminate the effects of damage and sensitization were made using different types of annealing processes. The results showed that after irradiating the dosimeters with dose > 250 Gy of 60Co gamma source, damage effects were observed. The sensitivity of the total area under the curve was decreased by a factor of ∼0.5 after irradiation at a pre-test dose of 2 kGy. However, the effects of radiation damage on each glow-peak are different. The glow-peak 2 was the only peak that was not affected by the high-dose irradiation. It has been shown that the degree of the radiation damage effect is related to the maximum dose-response function, f(D)max of the glow-peak. In general, significant radiation damage effects were observed for the glow-peaks of high f(D)max . Post-irradiation anneal at 280 °C for 30 min causes dramatic effects on the shape of the glow-curve and as well as on the sensitivity of the dosimeters. An increasing by a factor of ∼35 in the sensitivity of the total area under the curve was observed at a pre-test dose of 2 kGy. Improving the sensitivity of peak 7 by a factor of∼22 was the dominant factor in increasing the sensitivity of the dosimeters. On the other hand, an increasing by factors of ∼2.5 and ∼4 was found for peaks 2 and 5 respectively. On the other hand, a decreasing by a factor ∼0.5 was observed for peaks 3 and 4. At pre-test dose levels >250 Gy, a very strange and high intensity tail was observed in the high-temperature region of the glow-curves. The readout anneal was not enough to remove this tail. While, the furnace anneal could eliminate the sensitization effects but not the radiation damage effects on the sensitivity of the dosimeters.

  13. A Metric for Reducing False Positives in the Computer-Aided Detection of Breast Cancer from Dynamic Contrast-Enhanced Magnetic Resonance Imaging Based Screening Examinations of High-Risk Women.

    PubMed

    Levman, Jacob E D; Gallego-Ortiz, Cristina; Warner, Ellen; Causer, Petrina; Martel, Anne L

    2016-02-01

    Magnetic resonance imaging (MRI)-enabled cancer screening has been shown to be a highly sensitive method for the early detection of breast cancer. Computer-aided detection systems have the potential to improve the screening process by standardizing radiologists to a high level of diagnostic accuracy. This retrospective study was approved by the institutional review board of Sunnybrook Health Sciences Centre. This study compares the performance of a proposed method for computer-aided detection (based on the second-order spatial derivative of the relative signal intensity) with the signal enhancement ratio (SER) on MRI-based breast screening examinations. Comparison is performed using receiver operating characteristic (ROC) curve analysis as well as free-response receiver operating characteristic (FROC) curve analysis. A modified computer-aided detection system combining the proposed approach with the SER method is also presented. The proposed method provides improvements in the rates of false positive markings over the SER method in the detection of breast cancer (as assessed by FROC analysis). The modified computer-aided detection system that incorporates both the proposed method and the SER method yields ROC results equal to that produced by SER while simultaneously providing improvements over the SER method in terms of false positives per noncancerous exam. The proposed method for identifying malignancies outperforms the SER method in terms of false positives on a challenging dataset containing many small lesions and may play a useful role in breast cancer screening by MRI as part of a computer-aided detection system.

  14. Statistical properties of a utility measure of observer performance compared to area under the ROC curve

    NASA Astrophysics Data System (ADS)

    Abbey, Craig K.; Samuelson, Frank W.; Gallas, Brandon D.; Boone, John M.; Niklason, Loren T.

    2013-03-01

    The receiver operating characteristic (ROC) curve has become a common tool for evaluating diagnostic imaging technologies, and the primary endpoint of such evaluations is the area under the curve (AUC), which integrates sensitivity over the entire false positive range. An alternative figure of merit for ROC studies is expected utility (EU), which focuses on the relevant region of the ROC curve as defined by disease prevalence and the relative utility of the task. However if this measure is to be used, it must also have desirable statistical properties keep the burden of observer performance studies as low as possible. Here, we evaluate effect size and variability for EU and AUC. We use two observer performance studies recently submitted to the FDA to compare the EU and AUC endpoints. The studies were conducted using the multi-reader multi-case methodology in which all readers score all cases in all modalities. ROC curves from the study were used to generate both the AUC and EU values for each reader and modality. The EU measure was computed assuming an iso-utility slope of 1.03. We find mean effect sizes, the reader averaged difference between modalities, to be roughly 2.0 times as big for EU as AUC. The standard deviation across readers is roughly 1.4 times as large, suggesting better statistical properties for the EU endpoint. In a simple power analysis of paired comparison across readers, the utility measure required 36% fewer readers on average to achieve 80% statistical power compared to AUC.

  15. The shape of the glucose response curve during an oral glucose tolerance test heralds biomarkers of type 2 diabetes risk in obese youth

    USDA-ARS?s Scientific Manuscript database

    The shape of the glucose response curve during an oral glucose tolerance test (OGTT), monophasic versus biphasic, identifies physiologically distinct groups of individuals with differences in insulin secretion and sensitivity. We aimed to verify the value of the OGTT-glucose response curve against m...

  16. Breast-specific gamma camera imaging with 99mTc-MIBI has better diagnostic performance than magnetic resonance imaging in breast cancer patients: A meta-analysis.

    PubMed

    Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli

    2017-01-01

    This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.

  17. Evaluation of suspension array analysis for detection of egg yolk antibodies against Salmonella Enteritidis.

    PubMed

    Thomas, M E; Klinkenberg, D; Bergwerff, A A; van Eerden, E; Stegeman, J A; Bouma, A

    2010-06-01

    Salmonella enterica serovar Enteritidis (SE) is an important source of food-related diarrhoea in humans, and table eggs are considered the primordial source of contamination of the human food chain. Using eggs collected at egg-packing stations as samples could be a convenient strategy to detect colonization of layer flocks. The aim of this study was to evaluate egg yolk anti-Salmonella antibody detection using suspension array analysis. An egg yolk panel from contact-infected and non-colonized laying hens was used for the evaluation. Receiver Operating Characteristic (ROC) curves were generated to define a cut-off value and to assess the overall accuracy of the assay. The diagnostic sensitivity and specificity were estimated by maximum likelihood. Sensitivity was quantified on hen level and on sample level, and also quantified as a function of time since colonization. The area under the ROC curve was estimated at 0.984 (se 0.006, P<0.001). Of all colonized contact-infected hens, 67.6% [95% CI: 46.8, 100] developed an antibody response, which was detectable 17.4 days [14.3, 26.9] after colonization. In total, 98% [95.4, 99.4] of the 'immunopositive' hens had test positive eggs. The overall sensitivity of the immunological test was 66.7% [45.9, 98.7] and the specificity was 98.5% [97.8, 99.1]. This study provided essential parameters for optimizing surveillance programs based on detection of antibodies, and indicates that immunology based on examination of egg yolk gives important information about the Salmonella status of the flock. (c) 2010 Elsevier B.V. All rights reserved.

  18. Diagnostic accuracy of droplet digital PCR for detection of EGFR T790M mutation in circulating tumor DNA

    PubMed Central

    Tong, Xiang; Wang, Ye; Wang, Chengdi; Jin, Jing; Tian, Panwen; Li, Weimin

    2018-01-01

    Objectives Although different methods have been established to detect epidermal growth factor receptor (EGFR) T790M mutation in circulating tumor DNA (ctDNA), a wide range of diagnostic accuracy values were reported in previous studies. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for droplet digital PCR (ddPCR) in the diagnosis of EGFR T790M mutation based on ctDNA. Materials and methods A systematic review and meta-analysis were carried out based on resources from Pubmed, Web of Science, Embase and Cochrane Library up to October 11, 2017. Data were extracted to assess the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio (NLR), diagnostic OR (DOR), and areas under the summary receiver-operating characteristic curve (SROC). Results Eleven of 311 studies identified have met the including criteria. The sensitivity and specificity of ddPCR for the detection of T790M mutation in ctDNA ranged from 0.0% to 100.0% and 63.2% to 100.0%, respectively. For the pooled analysis, ddPCR had a performance of 70.1% (95% CI, 62.7%–76.7%) sensitivity, 86.9 % (95% CI, 80.6%–91.7%) specificity, 3.67 (95% CI, 2.33–5.79) PLR, 0.41 (95% CI, 0.32–0.55) NLR, and 10.83 (95% CI, 5.86–20.03) DOR, with the area under the SROC curve being 0.82. Conclusion The ddPCR harbored a good performance for detection of EGFR T790M mutation in ctDNA. PMID:29844700

  19. Safety assessment of underground vehicles passing over highly resilient curved tracks in the presence of a broken rail

    NASA Astrophysics Data System (ADS)

    Suárez, B.; Rodriguez, P.; Vázquez, M.; Fernández, I.

    2012-01-01

    Vehicle-track interaction for a new resilient slab track designed to reduce noise and vibration levels was analysed, in order to assess the derailment risk on a curved track when encountering a broken rail. Sensitivity of the rail support spacing of the relative position of the rail breakage between two adjacent rail supports and of running speed were analysed for two different elasticities of the rail fastening system. In none of the cases analysed was observed an appreciable difference between either of the elastic systems. As was expected, the most unfavourable situations were those with greater rail support spacing and those with greater distance from the breakage to the nearest rail support, although in none of the simulations performed did a derailment occur when running over the broken rail. When varying the running speed, the most favourable condition was obtained for an intermediate speed, due to the superposition of two antagonistic effects.

  20. Automatic and objective oral cancer diagnosis by Raman spectroscopic detection of keratin with multivariate curve resolution analysis

    NASA Astrophysics Data System (ADS)

    Chen, Po-Hsiung; Shimada, Rintaro; Yabumoto, Sohshi; Okajima, Hajime; Ando, Masahiro; Chang, Chiou-Tzu; Lee, Li-Tzu; Wong, Yong-Kie; Chiou, Arthur; Hamaguchi, Hiro-O.

    2016-01-01

    We have developed an automatic and objective method for detecting human oral squamous cell carcinoma (OSCC) tissues with Raman microspectroscopy. We measure 196 independent Raman spectra from 196 different points of one oral tissue sample and globally analyze these spectra using a Multivariate Curve Resolution (MCR) analysis. Discrimination of OSCC tissues is automatically and objectively made by spectral matching comparison of the MCR decomposed Raman spectra and the standard Raman spectrum of keratin, a well-established molecular marker of OSCC. We use a total of 24 tissue samples, 10 OSCC and 10 normal tissues from the same 10 patients, 3 OSCC and 1 normal tissues from different patients. Following the newly developed protocol presented here, we have been able to detect OSCC tissues with 77 to 92% sensitivity (depending on how to define positivity) and 100% specificity. The present approach lends itself to a reliable clinical diagnosis of OSCC substantiated by the “molecular fingerprint” of keratin.

  1. Analysis of influential factors on haze pollution in China

    NASA Astrophysics Data System (ADS)

    Liu, Xiao-Hong; Jiang, Keshen

    2018-05-01

    This study tests the hypothesis of Environmental Kuznets Curve (EKC) between PM10 concentrations and economic growth and analyzes the influential factors of PM10 concentrations from the economic perspective by using the panel data on the PM10 concentrations of 30 provinces from 2003 to 2015 in China. Results of the regression estimation from the fully modified OLS (FMOLS) method show that a relationship characterized by an inverted U-shaped curve is observed between PM10 concentrations and gross domestic product (GDP) per capita and that an EKC exists in China’s haze pollution problem. PM10 concentrations have the most sensitive response to GDP. The elastic coefficients of the possession of civilian vehicles, urbanization and trade openness are positive values. More importantly, the elastic coefficient of the tertiary industry proportion is less than 0. Increase in the proportion of tertiary industry can effectively alleviate China’s problem on haze pollution. Lastly, relevant countermeasures and suggestions are presented.

  2. SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, H; Sarkar, V; Rassiah-Szegedi, P

    2014-06-01

    Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffermore » RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.« less

  3. Diatomic predissociation line widths

    NASA Technical Reports Server (NTRS)

    Child, M. S.

    1973-01-01

    Predissociation by rotation and curve crossing in diatomic molecules is discussed. The pattern of predissociation line widths is seen as providing a highly sensitive yardstick for the determination of unknown potential curves. In addition, the computation of such a pattern for given potential curves is considered a matter of routine, unless the predissociation happens to occur from an adiabatic potential curve. Analytic formulas are used to provide physical insight into the details of the predissociation pattern, to the extent that a direct inversion procedure is developed for determination of the repulsive potential curves for Type 1 predissociations.

  4. Diagnostic value of DIAGNOdent in detecting caries under composite restorations of primary molars

    PubMed Central

    Sichani, Ava Vali; Javadinejad, Shahrzad; Ghafari, Roshanak

    2016-01-01

    Background: Direct observation cannot detect caries under restorations; therefore, the aim of this study was to compare the accuracy of radiographs and DIAGNOdent in detecting caries under restorations in primary teeth using histologic evaluation. Materials and Methods: A total of 74 previously extracted primary molars (37 with occlusal caries and 37 without caries) were used. Class 1 cavity preparations were made on each tooth by a single clinician and then the preparations were filled with composite resin. The accuracy of radiographs and DIAGNOdent in detecting caries was compared using histologic evaluation. The data were analyzed by SPSS version 21 using Chi-square, Mc Namara statistical tests and receiver operating characteristic curve. The significance was set at 0.05. Results: The sensitivity and specificity for DIAGNOdent were 70.97 and 83.72, respectively. Few false negative results were observed, and the positive predictive value was high (+PV = 75.9) and the area under curve was more than 0.70 therefore making DIAGNOdenta great method for detecting caries (P = 0.0001). Two observers evaluated the radiographs and both observers had low sensitivity ( first observer: 48.39) (second observer: 51.61) and high specificity (both observers: 79.07). The +PV was lower than DIAGNOdent and the area under curve for both observers was less than 0.70. However, the difference between the two methods was not significant. Conclusion: DIAGNOdent showed a greater accuracy in detecting secondary caries under primary molar restorations, compared to radiographs. Although DIAGNOdent is an effective method for detecting caries under composite restorations, it is better to be used as an adjunctive method alongside other detecting procedures. PMID:27605990

  5. Accuracy of optical spectroscopy for the detection of cervical intraepithelial neoplasia: Testing a device as an adjunct to colposcopy.

    PubMed

    Cantor, Scott B; Yamal, Jose-Miguel; Guillaud, Martial; Cox, Dennis D; Atkinson, E Neely; Benedet, John L; Miller, Dianne; Ehlen, Thomas; Matisic, Jasenka; van Niekerk, Dirk; Bertrand, Monique; Milbourne, Andrea; Rhodes, Helen; Malpica, Anais; Staerkel, Gregg; Nader-Eftekhari, Shahla; Adler-Storthz, Karen; Scheurer, Michael E; Basen-Engquist, Karen; Shinn, Eileen; West, Loyd A; Vlastos, Anne-Therese; Tao, Xia; Beck, J Robert; Macaulay, Calum; Follen, Michele

    2011-03-01

    Testing emerging technologies involves the evaluation of biologic plausibility, technical efficacy, clinical effectiveness, patient satisfaction, and cost-effectiveness. The objective of this study was to select an effective classification algorithm for optical spectroscopy as an adjunct to colposcopy and obtain preliminary estimates of its accuracy for the detection of CIN 2 or worse. We recruited 1,000 patients from screening and prevention clinics and 850 patients from colposcopy clinics at two comprehensive cancer centers and a community hospital. Optical spectroscopy was performed, and 4,864 biopsies were obtained from the sites measured, including abnormal and normal colposcopic areas. The gold standard was the histologic report of biopsies, read 2 to 3 times by histopathologists blinded to the cytologic, histopathologic, and spectroscopic results. We calculated sensitivities, specificities, receiver operating characteristic (ROC) curves, and areas under the ROC curves. We identified a cutpoint for an algorithm based on optical spectroscopy that yielded an estimated sensitivity of 1.00 [95% confidence interval (CI) = 0.92-1.00] and an estimated specificity of 0.71 [95% CI = 0.62-0.79] in a combined screening and diagnostic population. The positive and negative predictive values were 0.58 and 1.00, respectively. The area under the ROC curve was 0.85 (95% CI = 0.81-0.89). The per-patient and per-site performance were similar in the diagnostic and poorer in the screening settings. Like colposcopy, the device performs best in a diagnostic population. Alternative statistical approaches demonstrate that the analysis is robust and that spectroscopy works as well as or slightly better than colposcopy for the detection of CIN 2 to cancer. Copyright © 2010 UICC.

  6. Neutrophil Gelatinase-Associated Lipocalin Biomarker and Urinary Tract Infections: A Diagnostic Case-Control Study (NUTI Study).

    PubMed

    Price, Jameca Renee; Guran, Larissa; Lim, Jeong Youn; Megli, Christina J; Clark, Amanda L; Edwards, Sharon Renee; Denman, Mary Anna; Gregory, W Thomas

    Acute uncomplicated urinary tract infection (UTI) in women is often treated based on symptoms alone. Urinary tract infection symptoms are highly sensitive but lack specificity and result in overuse of antibiotics. We sought to determine if urine neutrophil gelatinase-associated lipocalin (uNGAL) levels in urine can accurately discriminate between UTI and healthy women. We recruited adult women aged 18 to 85 years presenting in the ambulatory setting from November 2014 to January 2016. Cases were defined as women with Centers for Disease Control and Prevention-defined UTI symptoms and a positive urine culture of more than 10 organisms/mL on a midstream clean-catch specimen. Women without UTI symptoms were matched by age and menopausal status as control subjects. Exclusion criteria were no UTIs within 8 weeks, urinary tract anomalies, renal disease, pregnancy, or diabetes. Clean-catch urine samples were obtained for measuring uNGAL, prior to antibiotic treatment of cases. We used Mann-Whitney U test to compare the 2 groups. Receiver operating characteristic curves were plotted to compare the performance of uNGAL to established urinary markers. We enrolled 50 UTI cases and 50 control subjects. Urine NGAL levels were higher in the UTI group than in the control subjects (P < 0.0001). Using a cutoff of 23.9 ng/mL, NGAL achieved 98% sensitivity and 100% specificity. The receiver operating characteristic curve had an area under the curve of 0.97 (95% confidence interval, 0.93-1.00), which was significantly high and showed that uNGAL can identify UTI. Urine NGAL has the potential as a biomarker for diagnosing UTIs in adult women.

  7. Calculating the number of shock waves, expulsion time, and optimum stone parameters based on noncontrast computerized tomography characteristics.

    PubMed

    Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram

    2013-11-01

    To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments <3 mm, ET was the time in days for the successful clearance of stone fragments. Correlation was performed between the stone characteristics, number of SWs, and ET. Two multiple regression analysis models defined the number of SWs and ET. Two receiver operating characteristic curves plotted the best MSD cutoff value and optimum SSD for a successful ESWL. Three hundred one patients were ESWL successes. A significant positive correlation was elicited between number of SWs and stone diameter, density and SSD; between ET and stone diameter and density. Multiple regressions concluded 2 equations: Number of SWs = 265.108 + 5.103 x1 + 22.39 x2 + 10.931 x3 ET (days) = -10.85 + 0.031 x1 + 2.11 x2 x1 = stone density (Hounsfield unit [HUs]), x2 = stone diameter (mm), and x3 = SSD (mm). Receiver operating characteristic curves demonstrated a cutoff value of ≤ 934 HUs with 94.4% sensitivity and 66.7% specificity and P = .0211. The SSD curve showed that a distance ≤ 99 mm was 85.7% sensitive, 87.5% specific, P <.0001. Stone disintegration is not recommended if MSD is >934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Pretransplantation soluble CD30 level as a predictor of acute rejection in kidney transplantation: a meta-analysis.

    PubMed

    Chen, Yile; Tai, Qiang; Hong, Shaodong; Kong, Yuan; Shang, Yushu; Liang, Wenhua; Guo, Zhiyong; He, Xiaoshun

    2012-11-15

    The question of whether high pretransplantation soluble CD30 (sCD30) level can be a predictor of kidney transplant acute rejection (AR) is under debate. Herein, we performed a meta-analysis on the predictive efficacy of sCD30 for AR in renal transplantation. PubMed (1966-2012), EMBASE (1988-2012), and Web of Science (1986-2012) databases were searched for studies concerning the predictive efficacy of sCD30 for AR after kidney transplantation. After a careful review of eligible studies, sensitivity, specificity, and other measures of the accuracy of sCD30 were pooled. A summary receiver operating characteristic curve was used to represent the overall test performance. Twelve studies enrolling 2507 patients met the inclusion criteria. The pooled estimates for pretransplantation sCD30 in prediction of allograft rejection risk were poor, with a sensitivity of 0.70 (95% confidence interval (CI), 0.66-0.74), a specificity of 0.48 (95% CI, 0.46-0.50), a positive likelihood ratio of 1.35 (95% CI, 1.20-1.53), a negative likelihood ratio of 0.68 (95% CI, 0.55-0.84), and a diagnostic odds ratio of 2.07 (95% CI, 1.54-2.80). The area under curve of the summary receiver operating characteristic curve was 0.60, indicating poor overall accuracy of the serum sCD30 level in the prediction of patients at risk for AR. The results of the meta-analysis show that the accuracy of pretransplantation sCD30 for predicting posttransplantation AR was poor. Prospective studies are needed to clarify the usefulness of this test for identifying risks of AR in transplant recipients.

  9. Accuracy of Brief Screening Tools for Identifying Postpartum Depression Among Adolescent Mothers

    PubMed Central

    Venkatesh, Kartik K.; Zlotnick, Caron; Triche, Elizabeth W.; Ware, Crystal

    2014-01-01

    OBJECTIVE: To evaluate the accuracy of the Edinburgh Postnatal Depression Scale (EPDS) and 3 subscales for identifying postpartum depression among primiparous adolescent mothers. METHODS: Mothers enrolled in a randomized controlled trial to prevent postpartum depression completed a psychiatric diagnostic interview and the 10-item EPDS at 6 weeks, 3 months, and 6 months postpartum. Three subscales of the EPDS were assessed as brief screening tools: 3-item anxiety subscale (EPDS-3), 7-item depressive symptoms subscale (EPDS-7), and 2-item subscale (EPDS-2) that resemble the Patient Health Questionnaire-2. Receiver operating characteristic curves and the areas under the curves for each tool were compared to assess accuracy. The sensitivities and specificities of each screening tool were calculated in comparison with diagnostic criteria for a major depressive disorder. Repeated-measures longitudinal analytical techniques were used. RESULTS: A total of 106 women contributed 289 postpartum visits; 18% of the women met criteria for incident postpartum depression by psychiatric diagnostic interview. When used as continuous measures, the full EPDS, EPDS-7, and EPDS-2 performed equally well (area under the curve >0.9). Optimal cutoff scores for a positive depression screen for the EPDS and EPDS-7 were lower (≥9 and ≥7, respectively) than currently recommended cutoff scores (≥10). At optimal cutoff scores, the EPDS and EPDS-7 both had sensitivities of 90% and specificities of >85%. CONCLUSIONS: The EPDS, EPDS-7, and EPDS-2 are highly accurate at identifying postpartum depression among adolescent mothers. In primary care pediatric settings, the EPDS and its shorter subscales have potential for use as effective depression screening tools. PMID:24344102

  10. Value of Examination Under Fluoroscopy for the Assessment of Sacroiliac Joint Dysfunction.

    PubMed

    Eskander, Jonathan P; Ripoll, Juan G; Calixto, Frank; Beakley, Burton D; Baker, Jeffrey T; Healy, Patrick J; Gunduz, O H; Shi, Lizheng; Clodfelter, Jamie A; Liu, Jinan; Kaye, Alan D; Sharma, Sanjay

    2015-01-01

    Pain emanating from the sacroiliac (SI) joint can have variable radiation patterns. Single physical examination tests for SI joint pain are inconsistent with multiple tests increasing both sensitivity and specificity. To evaluate the use of fluoroscopy in the diagnosis of SI joint pain. Prospective double blind comparison study. Pain clinic and radiology setting in urban Veterans Administration (VA) in New Orleans, Louisiana. Twenty-two adult men, patients at a southeastern United States VA interventional pain clinic, presented with unilateral low back pain of more than 2 months' duration. Patients with previous back surgery were excluded from the study. Each patient was given a Gapping test, Patrick (FABERE) test, and Gaenslen test. A second blinded physician placed each patient prone under fluoroscopic guidance, asking each patient to point to the most painful area. Pain was provoked by applying pressure with the heel of the palm in that area to determine the point of maximum tenderness. The area was marked with a radio-opaque object and was placed on the mark with a fluoroscopic imgage. A site within 1 cm of the SI joint was considered as a positive test. This was followed by a diagnostic injection under fluoroscopy with 1 mL 2% lidocaine. A positive result was considered as more than 2 hours of greater than 75% reduction in pain. Then, in 2-3 days this was followed by a therapeutic injection under fluoroscopy with 1 mL 0.5% bupivacaine and 40 mg methylprednisolone. Each patient was reassessed after 6 weeks. The sensitivity and specificity in addition to the positive and negative predictive values were determined for both the conventional examinations, as well as the examination under fluoroscopy. Finally, a receiver operating characteristic (ROC) curve was constructed to evaluate test performance. The sensitivity and specificity of the fluoroscopic examination were 0.82 and 0.80 respectively; Positive predictive value and negative predictive value were 0.93 and 0.57 respectively. The area under ROC curve was 0.812 which is considered a "good" test; however the area under ROC for the conventional examination were between 0.52-0.58 which is considered "poor to fail". Variation in anatomy of the SI joint, small sample size. Multiple structures of the SI joint complex can result in clinical symptoms of pain. These include intra-articular structures (degenerative arthritis, and inflammatory conditions) as well as extra-articular structures (ligaments, muscles, etc.).

  11. A multiplex real-time PCR assay, based on invA and pagC genes, for the detection and quantification of Salmonella enterica from cattle lymph nodes.

    PubMed

    Bai, Jianfa; Trinetta, Valentina; Shi, Xiaorong; Noll, Lance W; Magossi, Gabriela; Zheng, Wanglong; Porter, Elizabeth P; Cernicchiaro, Natalia; Renter, David G; Nagaraja, Tiruvoor G

    2018-05-01

    Cattle lymph nodes can harbor Salmonella and potentially contaminate beef products. We have developed and validated a new real-time PCR (qPCR) assay for the detection and quantification of Salmonella enterica in cattle lymph nodes. The assay targets both the invA and pagC genes, the most conserved molecular targets in Salmonella enterica. An 18S rRNA gene assay that amplifies from cattle and other animal species was also included as an internal control. Available DNA sequences for invA, pagC and 18S rRNA genes were used for primer and probe selections. Three Salmonella serotypes, S. Typhimurium, S. Anatum, and S. Montevideo, were used to assess the assay's analytical sensitivity. Correlation coefficients of standard curves generated for each target and for all three serotypes were >99% and qPCR amplification efficiencies were between 93% and 110%. Assay sensitivity was also determined using standard curve data generated from Salmonella-negative cattle lymph nodes spiked with 10-fold dilutions of the three Salmonella serotypes. Assay specificity was determined using Salmonella culture method, and qPCR testing on 36 Salmonella strains representing 33 serotypes, 38 Salmonella strains of unknown serotypes, 252 E. coli strains representing 40 serogroups, and 31 other bacterial strains representing 18 different species. A collection of 647 cattle lymph node samples from steers procured from the Midwest region of the US were tested by the qPCR, and compared to culture-method of detection. Salmonella prevalence by qPCR for pre-enriched and enriched lymph nodes was 19.8% (128/647) and 94.9% (614/647), respectively. A majority of qPCR positive pre-enriched samples (105/128) were at concentrations between 10 4 and 10 5  CFU/mL. Culture method detected Salmonella in 7.7% (50/647) and 80.7% (522/647) of pre- and post-enriched samples, respectively; 96.0% (48/50) of pre-enriched and 99.4% (519/522) of post-enriched culture-positive samples were also positive by qPCR. More samples tested positive by qPCR than by culture method, indicating that the real-time PCR assay was more sensitive. Our data indicate that this triplex qPCR can be used to accurately detect and quantify Salmonella enterica strains from cattle lymph node samples. The assay may serve as a useful tool to monitor the prevalence of Salmonella in beef production systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Effect of Light Quality on Stomatal Opening in Leaves of Xanthium strumarium L. 1

    PubMed Central

    Sharkey, Thomas D.; Raschke, Klaus

    1981-01-01

    Flux response curves were determined at 16 wavelengths of light for the conductance for water vapor of the lower epidermis of detached leaves of Xanthium strumarium L. An action spectrum of stomatal opening resulted in which blue light (wavelengths between 430 and 460 nanometers) was nearly ten times more effective than red light (wavelengths between 630 and 680 nanometers) in producing a conductance of 15 centimoles per square meter per second. Stomata responded only slightly to green light. An action spectrum of stomatal responses to red light corresponded to that of CO2 assimilation; the inhibitors of photosynthetic electron transport, cyanazine (2-chloro-4[1-cyano-1-methylethylamino]-6-ethylamino-s-triazine) and 3-(3,4-dichlorophenyl)-1,1-dimethylurea, eliminated the response to red light. This indicates that light absorption by chlorophyll is the cause of stomatal sensitivity to red light. Determination of flux response curves on leaves in the normal position (upper epidermis facing the light) or in the inverted position (lower epidermis facing the light) led to the conclusion that the photoreceptors for blue as well as for red light are located on or near the surfaces of the leaves; presumably they are in the guard cells themselves. PMID:16662069

  13. Audible handheld Doppler ultrasound determines reliable and inexpensive exclusion of significant peripheral arterial disease.

    PubMed

    Alavi, Afsaneh; Sibbald, R Gary; Nabavizadeh, Reza; Valaei, Farnaz; Coutts, Pat; Mayer, Dieter

    2015-12-01

    To determine the accuracy of audible arterial foot signals with an audible handheld Doppler ultrasound for identification of significant peripheral arterial disease as a simple, quick, and readily available bedside screening tool. Two hundred consecutive patients referred to an interprofessional wound care clinic underwent audible handheld Doppler ultrasound of both legs. As a control and comparator, a formal bilateral lower leg vascular study including the calculation of Ankle Brachial Pressure Index and toe pressure (TP) was performed at the vascular lab. Diagnostic reliability of audible handheld Doppler ultrasound was calculated versus Ankle Brachial Pressure Index as the gold standard test. A sensitivity of 42.8%, a specificity of 97.5%, negative predictive value of 94.10%, positive predictive value of 65.22%, positive likelihood ratio of 17.52, and negative likelihood ratio of 0.59. The univariable logistic regression model had an area under the curve of 0.78. There was a statistically significant difference at the 5% level between univariable and multivariable area under the curves of the dorsalis pedis and posterior tibial models (p < 0.001). Audible handheld Doppler ultrasound proved to be a reliable, simple, rapid, and inexpensive bedside exclusion test of peripheral arterial disease in diabetic and nondiabetic patients. © The Author(s) 2015.

  14. Sensitivity to friction for primary explosives.

    PubMed

    Matyáš, Robert; Šelešovský, Jakub; Musil, Tomáš

    2012-04-30

    The sensitivity to friction for a selection of primary explosives has been studied using a small BAM friction apparatus. The probit analysis was used for the construction of a sensitivity curve for each primary explosive tested. Two groups of primary explosives were chosen for measurement (a) the most commonly used industrially produced primary explosives (e.g. lead azide, tetrazene, dinol, lead styphnate) and (b) the most produced improvised primary explosives (e.g. triacetone triperoxide, hexamethylenetriperoxide diamine, mercury fulminate, acetylides of heavy metals). A knowledge of friction sensitivity is very important for determining manipulation safety for primary explosives. All the primary explosives tested were carefully characterised (synthesis procedure, shape and size of crystals). The sensitivity curves obtained represent a unique set of data, which cannot be found anywhere else in the available literature. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Stomatal Responses to Light and Drought Stress in Variegated Leaves of Hedera helix1

    PubMed Central

    Aphalo, Pedro J.; Sánchez, Rodolfo A.

    1986-01-01

    Direct and indirect mechanisms underlying the light response of stomata were studied in variegated leaves of the juvenile phase of Hedera helix L. Dose response curves of leaf conductance were measured with blue and red light in leaves kept in normal or in an inverted position. In the green portions of the leaves, the sensitivity to blue light was nearly 100 times higher than that to red light. No response to red light was observed in the white portions of the leaves up to 90 micromoles per square meter per second. Red light indirectly affected leaf conductance while blue light had a direct effect. Leaf conductance was found to be more sensitive to drought stress and showed a more persistent aftereffect in the white portions of the leaves. A differential effect of drought stress on the responses to blue and red light was also observed. PMID:16664900

  16. Stomatal Responses to Light and Drought Stress in Variegated Leaves of Hedera helix.

    PubMed

    Aphalo, P J; Sánchez, R A

    1986-07-01

    Direct and indirect mechanisms underlying the light response of stomata were studied in variegated leaves of the juvenile phase of Hedera helix L. Dose response curves of leaf conductance were measured with blue and red light in leaves kept in normal or in an inverted position. In the green portions of the leaves, the sensitivity to blue light was nearly 100 times higher than that to red light. No response to red light was observed in the white portions of the leaves up to 90 micromoles per square meter per second. Red light indirectly affected leaf conductance while blue light had a direct effect. Leaf conductance was found to be more sensitive to drought stress and showed a more persistent aftereffect in the white portions of the leaves. A differential effect of drought stress on the responses to blue and red light was also observed.

  17. CSF ADA Determination in Early Diagnosis of Tuberculous Meningitis in HIV-Infected Patients.

    PubMed

    Ghosh, Gopal Chandra; Sharma, Brijesh; Gupta, B B

    2016-01-01

    Tuberculous and Cryptococcal meningitis are common in HIV patients. A highly specific and sensitive rapid test for diagnosis of Tuberculous meningitis especially in setting of HIV is not available in developing countries where the burden of disease is high. We measured ADA (adenosine deaminase) levels using spectrophotometric method in the CSF of HIV patients with meningitis to differentiate Tuberculous meningitis from meningitis due to other causes. Kruskal-Wallis test was used to compare ADA values between tuberculous meningitis (TBM) and nontuberculous (non-TB) meningitis patients and a receiver-operating characteristic (ROC) analysis curve was drawn from these values. Levels of ADA in the CSF of patients with TBM were significantly higher than those in patients with meningitis due to other causes. CSF ADA level determination with a cut-off value of 6 IU/L was found to be highly specific and fairly sensitive test for the diagnosis of TBM in HIV positive patients.

  18. Space shuttle entry and landing navigation analysis

    NASA Technical Reports Server (NTRS)

    Jones, H. L.; Crawford, B. S.

    1974-01-01

    A navigation system for the entry phase of a Space Shuttle mission which is an aided-inertial system which uses a Kalman filter to mix IMU data with data derived from external navigation aids is evaluated. A drag pseudo-measurement used during radio blackout is treated as an additional external aid. A comprehensive truth model with 101 states is formulated and used to generate detailed error budgets at several significant time points -- end-of-blackout, start of final approach, over runway threshold, and touchdown. Sensitivity curves illustrating the effect of variations in the size of individual error sources on navigation accuracy are presented. The sensitivity of the navigation system performance to filter modifications is analyzed. The projected overall performance is shown in the form of time histories of position and velocity error components. The detailed results are summarized and interpreted, and suggestions are made concerning possible software improvements.

  19. Diagnostic value of soluble B7-H4 and carcinoembryonic antigen in distinguishing malignant from benign pleural effusion.

    PubMed

    Jing, Xiaogang; Wei, Fei; Li, Jing; Dai, Lingling; Wang, Xi; Jia, Liuqun; Wang, Huan; An, Lin; Yang, Yuanjian; Zhang, Guojun; Cheng, Zhe

    2018-03-01

    To explore the diagnostic value of joint detection of soluble B7-H4 (sB7-H4) and carcinoembryonic antigen (CEA) in identifying malignant pleural effusion (MPE) from benign pleural effusion (BPE). A total of 97 patients with pleural effusion specimens were enrolled from The First Affiliated Hospital of Zhengzhou University between June 2014 and December 2015. All cases were categorized into malignant pleural effusion group (n = 55) and benign pleural effusion group (n = 42) according to etiologies. Enzyme-linked immunosorbent assay was applied to examine the levels of sB7-H4 in pleural effusion and meanwhile CEA concentrations were detected by electro-chemiluminescence immunoassays. Receiver operating characteristic (ROC) curve was established to assess the diagnostic value of sB7-H4 and CEA in pleural effusion. The correlation between sB7-H4 and CEA levels was analyzed by Pearson's product-moment. The concentrations of sB7-H4 and CEA in MPE exhibited obviously higher than those of BPE ([60.08 ± 35.04] vs. [27.26 ± 9.55] ng/ml, P = .000; [41.49 ± 37.16] vs. [2.41 ± 0.94] ng/ml, P = .000). The AUC area under ROC curve of sB7-H4 and CEA was 0.884 and 0.954, respectively. Two cutoff values by ROC curve analysis of sB7-H4 36.5 ng/ml and CEA 4.18 ng/ml were obtained, with a corresponding sensitivity (81.82%, 87.28%), specificity (90.48%, 95.24%), accuracy (85.57%, 90.72%), positive predictive value (PPV) (91.84%, 96.0%), negative predictive value (NPV) (79.17%, 85.11%), positive likelihood ratio (PLR) (8.614, 18.327), and negative likelihood ratio (NLR) (0.201, 0.134). When sB7-H4 and CEA were combined to detect pleural effusion, it obtained a higher sensitivity 90.91% and specificity 97.62%. Furthermore, correlation analysis result showed that the level of sB7-H4 was correlated with CEA level (r = .770, P = .000). sB7-H4 was a potentially valuable tumor marker in the differentiation between BPE and MPE. The combined detection of sB7-H4 and CEA could improve the diagnostic sensitivity and specificity for MPE. © 2017 John Wiley & Sons Ltd.

  20. Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists.

    PubMed

    Torres-Mejía, Gabriela; Smith, Robert A; Carranza-Flores, María de la Luz; Bogart, Andy; Martínez-Matsushita, Louis; Miglioretti, Diana L; Kerlikowske, Karla; Ortega-Olvera, Carolina; Montemayor-Varela, Ernesto; Angeles-Llerenas, Angélica; Bautista-Arredondo, Sergio; Sánchez-González, Gilberto; Martínez-Montañez, Olga G; Uscanga-Sánchez, Santos R; Lazcano-Ponce, Eduardo; Hernández-Ávila, Mauricio

    2015-05-16

    An alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries. We evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed. Radiographer's sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7-86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7-57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6-0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms. Given the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists in countries with shortages of radiologists. Further studies are required to assess the effectiveness of different training programs in order to obtain acceptable screening accuracy, as well as the best approaches for the use of non-physician readers to interpret screening mammography.

  1. Imperfection Sensitivity of Nonlinear Vibration of Curved Single-Walled Carbon Nanotubes Based on Nonlocal Timoshenko Beam Theory

    PubMed Central

    Eshraghi, Iman; Jalali, Seyed K.; Pugno, Nicola Maria

    2016-01-01

    Imperfection sensitivity of large amplitude vibration of curved single-walled carbon nanotubes (SWCNTs) is considered in this study. The SWCNT is modeled as a Timoshenko nano-beam and its curved shape is included as an initial geometric imperfection term in the displacement field. Geometric nonlinearities of von Kármán type and nonlocal elasticity theory of Eringen are employed to derive governing equations of motion. Spatial discretization of governing equations and associated boundary conditions is performed using differential quadrature (DQ) method and the corresponding nonlinear eigenvalue problem is iteratively solved. Effects of amplitude and location of the geometric imperfection, and the nonlocal small-scale parameter on the nonlinear frequency for various boundary conditions are investigated. The results show that the geometric imperfection and non-locality play a significant role in the nonlinear vibration characteristics of curved SWCNTs. PMID:28773911

  2. A principled approach to setting optimal diagnostic thresholds: where ROC and indifference curves meet.

    PubMed

    Irwin, R John; Irwin, Timothy C

    2011-06-01

    Making clinical decisions on the basis of diagnostic tests is an essential feature of medical practice and the choice of the decision threshold is therefore crucial. A test's optimal diagnostic threshold is the threshold that maximizes expected utility. It is given by the product of the prior odds of a disease and a measure of the importance of the diagnostic test's sensitivity relative to its specificity. Choosing this threshold is the same as choosing the point on the Receiver Operating Characteristic (ROC) curve whose slope equals this product. We contend that a test's likelihood ratio is the canonical decision variable and contrast diagnostic thresholds based on likelihood ratio with two popular rules of thumb for choosing a threshold. The two rules are appealing because they have clear graphical interpretations, but they yield optimal thresholds only in special cases. The optimal rule can be given similar appeal by presenting indifference curves, each of which shows a set of equally good combinations of sensitivity and specificity. The indifference curve is tangent to the ROC curve at the optimal threshold. Whereas ROC curves show what is feasible, indifference curves show what is desirable. Together they show what should be chosen. Copyright © 2010 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  3. The determination of substrate conditions from the orientations of solitary rugose corals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolton, J.C.; Driese, S.G.

    1990-10-01

    The substrate conditions of mudstone strata formed in ancient epicontinental settings may be determined from taphonomic assemblages of solitary rugose corals. Equal-area plots on the orientations of preserved corals can be used to infer whether subsequent hydrodynamic conditions affected any post-mortem reworking of the corals. Mechanically stable positions for curved corals can be determined. Curved corals preserved in mechanically stable positions are interpreted to have been deposited on firm or hard substrates. Curved corals preserved in mechanically unstable positions were probably embedded in soft or soupy substrates.

  4. Optimal waist circumference cutoff value for defining the metabolic syndrome in postmenopausal Latin American women.

    PubMed

    Blümel, Juan E; Legorreta, Deborah; Chedraui, Peter; Ayala, Felix; Bencosme, Ascanio; Danckers, Luis; Lange, Diego; Espinoza, Maria T; Gomez, Gustavo; Grandia, Elena; Izaguirre, Humberto; Manriquez, Valentin; Martino, Mabel; Navarro, Daysi; Ojeda, Eliana; Onatra, William; Pozzo, Estela; Prada, Mariela; Royer, Monique; Saavedra, Javier M; Sayegh, Fabiana; Tserotas, Konstantinos; Vallejo, Maria S; Zuñiga, Cristina

    2012-04-01

    The aim of this study was to determine an optimal waist circumference (WC) cutoff value for defining the metabolic syndrome (METS) in postmenopausal Latin American women. A total of 3,965 postmenopausal women (age, 45-64 y), with self-reported good health, attending routine consultation at 12 gynecological centers in major Latin American cities were included in this cross-sectional study. Modified guidelines of the US National Cholesterol Education Program, Adult Treatment Panel III were used to assess METS risk factors. Receiver operator characteristic curve analysis was used to obtain an optimal WC cutoff value best predicting at least two other METS components. Optimal cutoff values were calculated by plotting the true-positive rate (sensitivity) against the false-positive rate (1 - specificity). In addition, total accuracy, distance to receiver operator characteristic curve, and the Youden Index were calculated. Of the participants, 51.6% (n = 2,047) were identified as having two or more nonadipose METS risk components (excluding a positive WC component). These women were older, had more years since menopause onset, used hormone therapy less frequently, and had higher body mass indices than women with fewer metabolic risk factors. The optimal WC cutoff value best predicting at least two other METS components was determined to be 88 cm, equal to that defined by the Adult Treatment Panel III. A WC cutoff value of 88 cm is optimal for defining METS in this postmenopausal Latin American series.

  5. Another collision for the Coma cluster

    NASA Technical Reports Server (NTRS)

    Vikhlinin, A.; Forman, W.; Jones, C.

    1996-01-01

    The wavelet transform analysis of the Rosat position sensitive proportional counter (PSPC) images of the Coma cluster are presented. The analysis shows, on small scales, a substructure dominated by two extended sources surrounding the two bright clusters NGC 4874 and NGC 4889. On scales of about 2 arcmin to 3 arcmin, the analysis reveals a tail of X-ray emission originating near the cluster center, curving to the south and east for approximately 25 arcmin and ending near the galaxy NGC 4911. The results are interpreted in terms of a merger of a group, having a core mass of approximately 10(exp 13) solar mass, with the main body of the Coma cluster.

  6. Neck curve polynomials in neck rupture model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurniadi, Rizal; Perkasa, Yudha S.; Waris, Abdul

    2012-06-06

    The Neck Rupture Model is a model that explains the scission process which has smallest radius in liquid drop at certain position. Old fashion of rupture position is determined randomly so that has been called as Random Neck Rupture Model (RNRM). The neck curve polynomials have been employed in the Neck Rupture Model for calculation the fission yield of neutron induced fission reaction of {sup 280}X{sub 90} with changing of order of polynomials as well as temperature. The neck curve polynomials approximation shows the important effects in shaping of fission yield curve.

  7. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performancemore » of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8–1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. Conclusions: By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.« less

  8. A Galilean Invariant Explicit Algebraic Reynolds Stress Model for Curved Flows

    NASA Technical Reports Server (NTRS)

    Girimaji, Sharath

    1996-01-01

    A Galilean invariant weak-equilbrium hypothesis that is sensitive to streamline curvature is proposed. The hypothesis leads to an algebraic Reynolds stress model for curved flows that is fully explicit and self-consistent. The model is tested in curved homogeneous shear flow: the agreement is excellent with Reynolds stress closure model and adequate with available experimental data.

  9. Comparison of two correlated ROC curves at a given specificity or sensitivity level.

    PubMed

    Bantis, Leonidas E; Feng, Ziding

    2016-10-30

    The receiver operating characteristic (ROC) curve is the most popular statistical tool for evaluating the discriminatory capability of a given continuous biomarker. The need to compare two correlated ROC curves arises when individuals are measured with two biomarkers, which induces paired and thus correlated measurements. Many researchers have focused on comparing two correlated ROC curves in terms of the area under the curve (AUC), which summarizes the overall performance of the marker. However, particular values of specificity may be of interest. We focus on comparing two correlated ROC curves at a given specificity level. We propose parametric approaches, transformations to normality, and nonparametric kernel-based approaches. Our methods can be straightforwardly extended for inference in terms of ROC -1 (t). This is of particular interest for comparing the accuracy of two correlated biomarkers at a given sensitivity level. Extensions also involve inference for the AUC and accommodating covariates. We evaluate the robustness of our techniques through simulations, compare them with other known approaches, and present a real-data application involving prostate cancer screening. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Contribution of flow-volume curves to the detection of central airway obstruction*

    PubMed Central

    Raposo, Liliana Bárbara Perestrelo de Andrade e; Bugalho, António; Gomes, Maria João Marques

    2013-01-01

    OBJECTIVE: To assess the sensitivity and specificity of flow-volume curves in detecting central airway obstruction (CAO), and to determine whether their quantitative and qualitative criteria are associated with the location, type and degree of obstruction. METHODS: Over a four-month period, we consecutively evaluated patients with bronchoscopy indicated. Over a one-week period, all patients underwent clinical evaluation, flow-volume curve, bronchoscopy, and completed a dyspnea scale. Four reviewers, blinded to quantitative and clinical data, and bronchoscopy results, classified the morphology of the curves. A fifth reviewer determined the morphological criteria, as well as the quantitative criteria. RESULTS: We studied 82 patients, 36 (44%) of whom had CAO. The sensitivity and specificity of the flow-volume curves in detecting CAO were, respectively, 88.9% and 91.3% (quantitative criteria) and 30.6% and 93.5% (qualitative criteria). The most prevalent quantitative criteria in our sample were FEF50%/FIF50% ≥ 1, in 83% of patients, and FEV1/PEF ≥ 8 mL . L–1 . min–1, in 36%, both being associated with the type, location, and degree of obstruction (p < 0.05). There was concordance among the reviewers as to the presence of CAO. There is a relationship between the degree of obstruction and dyspnea. CONCLUSIONS: The quantitative criteria should always be calculated for flow-volume curves in order to detect CAO, because of the low sensitivity of the qualitative criteria. Both FEF50%/FIF50% ≥ 1 and FEV1/PEF ≥ 8 mL . L–1 . min–1 were associated with the location, type and degree of obstruction. PMID:24068266

  11. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    PubMed

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  12. Reliability of N-terminal proBNP assay in diagnosis of left ventricular systolic dysfunction within representative and high risk populations.

    PubMed

    Hobbs, F D R; Davis, R C; Roalfe, A K; Hare, R; Davies, M K

    2004-08-01

    To determine the performance of a new NT-proBNP assay in comparison with brain natriuretic peptide (BNP) in identifying left ventricular systolic dysfunction (LVSD) in randomly selected community populations. Blood samples were taken prospectively in the community from 591 randomly sampled individuals over the age of 45 years, stratified for age and socioeconomic status and divided into four cohorts (general population; clinically diagnosed heart failure; patients on diuretics; and patients deemed at high risk of heart failure). Definite heart failure (left ventricular ejection fraction (LVEF) < 40%) was identified in 33 people. Samples were handled as though in routine clinical practice. The laboratories undertaking the assays were blinded. Using NT-proBNP to diagnose LVEF < 40% in the general population, a level of > 40 pmol/l had 80% sensitivity, 73% specificity, 5% positive predictive value (PPV), 100% negative predictive value (NPV), and an area under the receiver-operator characteristic curve (AUC) of 76% (95% confidence interval (CI) 46% to 100%). For BNP to diagnose LVSD, a cut off level of > 33 pmol/l had 80% sensitivity, 88% specificity, 10% PPV, 100% NPV, and AUC of 88% (95% CI 75% to 100%). Similar NPVs were found for patients randomly screened from the three other populations. Both NT-proBNP and BNP have value in diagnosing LVSD in a community setting, with similar sensitivities and specificities. Using a high cut off for positivity will confirm the diagnosis of LVSD but will miss cases. At lower cut off values, positive results will require cardiac imaging to confirm LVSD.

  13. Association of early National Institutes of Health Stroke Scale improvement with vessel recanalization and functional outcome after intravenous thrombolysis in ischemic stroke.

    PubMed

    Kharitonova, Tatiana; Mikulik, Robert; Roine, Risto O; Soinne, Lauri; Ahmed, Niaz; Wahlgren, Nils

    2011-06-01

    Early neurological improvement (ENI) after thrombolytic therapy of acute stroke has been linked with recanalization and favorable outcome, although its definition shows considerable variation. We tested the ability of ENI, as defined in previous publications, to predict vessel recanalization and 3-month functional outcome after intravenous thrombolysis recorded in an extensive patient cohort in the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register (SITS-ISTR). Of 21,534 patients registered between December 2002 and December 2008, 798 patients (3.7%) had CT- or MR angiography-documented baseline vessel occlusion and also angiography data at 22 to 36 hours post-treatment. ENI definitions assessed at 2 hours and 24 hours post-treatment were (1) National Institutes of Health Stroke Scale (NIHSS) score improvement ≥4 points from baseline; (2) NIHSS 0, 1, or improvement ≥8; (3) NIHSS ≤3 or improvement ≥10; (4) improvement by 20%; (5) 40% from baseline; or (6) NIHSS score 0 to 1. Receiver operating curve analysis and multiple logistic regression were performed to evaluate the association of ENI with vessel recanalization and favorable functional outcome (modified Rankin Scale score 0 to 2 at 3 months). ENI at 2 hours had fair accuracy to diagnose recanalization as derived from receiver operating curve analysis. Definitions of improvement based on percent of NIHSS score change from baseline demonstrate better accuracy to diagnose recanalization at 2 hours and 24 hours than the definitions based on NIHSS cutoffs (the best performance at 2 hours was area under the curve 0.633, sensitivity 58%, specificity 69%, positive predictive value 68%, and negative predictive value 59% for 20% improvement; and area under the curve 0.692, sensitivity 69%, specificity 70%, positive predictive value 70%, and negative predictive value 62% for 40% improvement at 24 hours). ENI-predicted functional outcome with OR 2.8 to 6.0 independently from recanalization in the angiography cohort (n=695) and with OR of 6.9 to 9.7 in the whole cohort (n=18 181). Early 20% neurological improvement at 2 hours was the best predictor of 3-month functional outcome and recanalization after thrombolysis, although fairly accurate, and may serve as a surrogate marker of recanalization if only imaging evaluation of vessel status is not available. If recanalization status is required after intravenous thrombolysis, vascular imaging is recommended despite ENI.

  14. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay.

    PubMed

    Lordkipanidzé, Marie; Lowe, Gillian C; Kirkby, Nicholas S; Chan, Melissa V; Lundberg, Martina H; Morgan, Neil V; Bem, Danai; Nisar, Shaista P; Leo, Vincenzo C; Jones, Matthew L; Mundell, Stuart J; Daly, Martina E; Mumford, Andrew D; Warner, Timothy D; Watson, Steve P

    2014-02-20

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167.

  15. Validity of the language development survey in infants born preterm.

    PubMed

    Beaulieu-Poulin, Camille; Simard, Marie-Noëlle; Babakissa, Hélène; Lefebvre, Francine; Luu, Thuy Mai

    2016-07-01

    Preterm infants are at greater risk of language delay. Early identification of language delay is essential to improve functional outcome in these children. To examine the concurrent validity of Rescorla's Language Development Survey and the Bayley Scales of Infant and Toddler Development (Bayley-III) at 18months corrected age in preterm infants. Test accuracy study. 189 preterm infants born <29weeks were assessed at 18months. The Language Development Survey, a parent-reported screening instrument, was administered in French concurrently with the Language Scales of the Bayley-III. Receiver-Operating-Characteristics curves were used to determine optimal cut-off score on the Language Development Survey to identify Bayley-III score <85. Sensitivity, specificity, positive and negative predictive values, and κ coefficient were calculated. Using Rescorla's original cut-off scores of ≤10 words for boys and ≤24 for girls, sensitivity was 76% and 88% for boys and girls, respectively, and specificity was 73% and 52% for boys and girls, respectively, in identifying language delay as per the Bayley-III. The optimal threshold was ≤10 words for both boys and girls. In girls, lowering the cut-off score decreased sensitivity (79%), but improved specificity (82%), thus lowering the number of false-positives. Our findings support using the Language Development Survey as an expressive language screener in preterm infants. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Sensitivity and specificity of clinician administered screening instruments in detecting depression among HIV-positive individuals in Uganda.

    PubMed

    Akena, Dickens; Joska, John; Obuku, Ekwaro A; Stein, Dan J

    2013-01-01

    Depressive disorders are highly prevalent in Africa where diseases such as HIV/AIDS are common. The aim of this study was to assess the validity of commonly used depression screening instruments in a setting characterized by low literacy, where patients may not be able to self-administer depression scales. We explored the validity of the Patient Health Questionaire-9 (PHQ-9), Centre for Epidemiological Surveys for Depression (CES-D), and the Kessler-10 (K-10), using the Mini International Neuropsychiatric Instrument (MINI) as a gold standard in 368 persons living with HIV/AIDS (PLWHA) in Uganda. The shorter versions of the K-10 and PHQ-9 were extracted to assess their performance in comparison to the longer versions. We used STATA 11.2 to analyze the data. The prevalence of a MINI defined depression in this patient sample was 17.4%. The three instruments all performed well, with areas under the curve (AUC) ranging from 0.82 to 0.96. The PHQ-9 showed the best performance characteristics with an AUC of 0.96, a sensitivity of 91.6%, and specificity 81.2%. The extracted versions performed more modestly. All three instruments showed good properties as screening tools; the PHQ-9 has particularly high sensitivity and specificity, and so can be considered useful for screening HIV-positive patients for depression.

  17. Highly sensitive three-dimensional interdigitated microelectrode for microparticle detection using electrical impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Chang, Fu-Yu; Chen, Ming-Kun; Wang, Min-Haw; Jang, Ling-Sheng

    2016-02-01

    Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz.

  18. Effects of acute hyperthermia on the carotid baroreflex control of heart rate in humans

    NASA Astrophysics Data System (ADS)

    Yamazaki, F.; Sagawa, S.; Torii, R.; Endo, Y.; Shiraki, K.

    The purpose of this study was to examine the effect of hyperthermia on the carotid baroreceptor-cardiac reflexes in humans. Nine healthy males underwent acute hyperthermia (esophageal temperature 38.0° C) produced by hot water-perfused suits. Beat-to-beat heart rate (HR) responses were determined during positive and negative R-wave-triggered neck pressure steps from +40 to -65 mm Hg during normothermia and hyperthermia. The carotid baroreceptor-cardiac reflex sensitivity was evaluated from the maximum slope of the HR response to changes in carotid distending pressure. Buffering capacity of the HR response to carotid distending pressure was evaluated in % from a reference point calculated as (HR at 0 mm Hg neck pressure-minimum HR)/HR range ×100. An upward shift of the curve was evident in hyperthermia because HR increased from 57.7+/-2.4 beats/min in normothermia to 88.7+/-4.1 beats/min in hyperthermia (P<0.05) without changes in mean arterial pressure. The maximum slope of the curve in hyperthermia was similar to that in normothermia. The reference point was increased (P<0.05) during hyperthermia. These results suggest that the sensitivity of the carotid baroreflex of HR remains unchanged in hyperthermia. However, the capacity for tachycardia response to rapid onset of hypotension is reduced and the capacity for bradycardia response to sudden hypertension is increased during acute hyperthermia.

  19. [The value of PHI/PCA3 in the early diagnosis of prostate cancer].

    PubMed

    Tan, S J; Xu, L W; Xu, Z; Wu, J P; Liang, K; Jia, R P

    2016-01-12

    To investigate the value of prostate health index (PHI) and prostate cancer gene 3 (PCA3) in the early diagnosis of prostate cancer (PCa). A total of 190 patients with abnormal serum prostate specific antigen (PSA) or abnormal digital rectal examination were enrolled. They were all underwent initial biopsy and 11 of them were also underwent repeated biopsy. In addition, 25 healthy cases (with normal digital rectal examination and PSA<4 ng/ml) were the control group.The PHI and PCA3 were detected by using immunofluorescence and Loop-Mediated Isothermal Amplification (LAMP). The sensitivity and specificity of diagnosis were determined by ROC curve.In addition, the relationship between PHI/PSA and the Gleason score and clinical stage were analyzed. A total of 89 patients were confirmed PCa by Pathological diagnosis. The other 101 patients were diagnosed as benign prostatic hyperplasia (BPH). The sensitivity and specificity of PCA3 test were 85.4% was 92.1%. Area under curve (AUC) of PHI is higher than AUC of PSA (0.727>0.699). The PHI in peripheral blood was positively correlated with Gleason score and clinical stage. The detection of PCA3 and PHI shows excellent detecting effectiveness. Compared with single PSA, the combined detection of PHI and PCA3 improved the diagnostic specificity. It can provide a new method for the early diagnosis in prostate cancer and avoid unnecessary biopsies.

  20. FEV1 is a better predictor of mortality than FVC: the PLATINO cohort study.

    PubMed

    Menezes, Ana Maria B; Pérez-Padilla, Rogelio; Wehrmeister, Fernando César; Lopez-Varela, Maria Victorina; Muiño, Adriana; Valdivia, Gonzalo; Lisboa, Carmen; Jardim, José Roberto B; de Oca, Maria Montes; Talamo, Carlos; Bielemann, Renata; Gazzotti, Mariana; Laurenti, Ruy; Celli, Bartolomé; Victora, Cesar G

    2014-01-01

    To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort. Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated. Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVC

  1. Neural population encoding and decoding of sound source location across sound level in the rabbit inferior colliculus

    PubMed Central

    Delgutte, Bertrand

    2015-01-01

    At lower levels of sensory processing, the representation of a stimulus feature in the response of a neural population can vary in complex ways across different stimulus intensities, potentially changing the amount of feature-relevant information in the response. How higher-level neural circuits could implement feature decoding computations that compensate for these intensity-dependent variations remains unclear. Here we focused on neurons in the inferior colliculus (IC) of unanesthetized rabbits, whose firing rates are sensitive to both the azimuthal position of a sound source and its sound level. We found that the azimuth tuning curves of an IC neuron at different sound levels tend to be linear transformations of each other. These transformations could either increase or decrease the mutual information between source azimuth and spike count with increasing level for individual neurons, yet population azimuthal information remained constant across the absolute sound levels tested (35, 50, and 65 dB SPL), as inferred from the performance of a maximum-likelihood neural population decoder. We harnessed evidence of level-dependent linear transformations to reduce the number of free parameters in the creation of an accurate cross-level population decoder of azimuth. Interestingly, this decoder predicts monotonic azimuth tuning curves, broadly sensitive to contralateral azimuths, in neurons at higher levels in the auditory pathway. PMID:26490292

  2. A score model for predicting post-liver transplantation survival in HBV cirrhosis-related hepatocellular carcinoma recipients: a single center 5-year experience.

    PubMed

    Wang, Li-Ying; Zheng, Shu-Sen; Xu, Xiao; Wang, Wei-Lin; Wu, Jian; Zhang, Min; Shen, Yan; Yan, Sheng; Xie, Hai-Yang; Chen, Xin-Hua; Jiang, Tian-An; Chen, Fen

    2015-02-01

    The prognostic prediction of liver transplantation (LT) guides the donor organ allocation. However, there is currently no satisfactory model to predict the recipients' outcome, especially for the patients with HBV cirrhosis-related hepatocellular carcinoma (HCC). The present study was to develop a quantitative assessment model for predicting the post-LT survival in HBV-related HCC patients. Two hundred and thirty-eight LT recipients at the Liver Transplant Center, First Affiliated Hospital, Zhejiang University School of Medicine between 2008 and 2013 were included in this study. Their post-LT prognosis was recorded and multiple risk factors were analyzed using univariate and multivariate analyses in Cox regression. The score model was as follows: 0.114X(Child-Pugh score)-0.002X(positive HBV DNA detection time)+0.647X(number of tumor nodules)+0.055X(max diameter of tumor nodules)+0.231XlnAFP+0.437X(tumor differentiation grade). The receiver operating characteristic curve analysis showed that the area under the curve of the scoring model for predicting the post-LT survival was 0.887. The cut-off value was 1.27, which was associated with a sensitivity of 72.5% and a specificity of 90.7%, respectively. The quantitative score model for predicting post-LT survival proved to be sensitive and specific.

  3. Updating schematic emotional facial expressions in working memory: Response bias and sensitivity.

    PubMed

    Tamm, Gerly; Kreegipuu, Kairi; Harro, Jaanus; Cowan, Nelson

    2017-01-01

    It is unclear if positive, negative, or neutral emotional expressions have an advantage in short-term recognition. Moreover, it is unclear from previous studies of working memory for emotional faces whether effects of emotions comprise response bias or sensitivity. The aim of this study was to compare how schematic emotional expressions (sad, angry, scheming, happy, and neutral) are discriminated and recognized in an updating task (2-back recognition) in a representative sample of birth cohort of young adults. Schematic facial expressions allow control of identity processing, which is separate from expression processing, and have been used extensively in attention research but not much, until now, in working memory research. We found that expressions with a U-curved mouth (i.e., upwardly curved), namely happy and scheming expressions, favoured a bias towards recognition (i.e., towards indicating that the probe and the stimulus in working memory are the same). Other effects of emotional expression were considerably smaller (1-2% of the variance explained)) compared to a large proportion of variance that was explained by the physical similarity of items being compared. We suggest that the nature of the stimuli plays a role in this. The present application of signal detection methodology with emotional, schematic faces in a working memory procedure requiring fast comparisons helps to resolve important contradictions that have emerged in the emotional perception literature. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    PubMed

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.

  5. The power metric: a new statistically robust enrichment-type metric for virtual screening applications with early recovery capability.

    PubMed

    Lopes, Julio Cesar Dias; Dos Santos, Fábio Mendes; Martins-José, Andrelly; Augustyns, Koen; De Winter, Hans

    2017-01-01

    A new metric for the evaluation of model performance in the field of virtual screening and quantitative structure-activity relationship applications is described. This metric has been termed the power metric and is defined as the fraction of the true positive rate divided by the sum of the true positive and false positive rates, for a given cutoff threshold. The performance of this metric is compared with alternative metrics such as the enrichment factor, the relative enrichment factor, the receiver operating curve enrichment factor, the correct classification rate, Matthews correlation coefficient and Cohen's kappa coefficient. The performance of this new metric is found to be quite robust with respect to variations in the applied cutoff threshold and ratio of the number of active compounds to the total number of compounds, and at the same time being sensitive to variations in model quality. It possesses the correct characteristics for its application in early-recognition virtual screening problems.

  6. Vaginal symptoms and bacterial vaginosis (BV): how useful is self-report? Development of a screening tool for predicting BV status.

    PubMed

    Nelson, D B; Bellamy, S; Odibo, A; Nachamkin, I; Ness, R B; Allen-Taylor, L

    2007-11-01

    Vaginal complaints compel an evaluation of bacterial vaginosis (BV), however, many cases of BV are asymptomatic. We evaluated the sensitivity and specificity of vaginal symptoms in the diagnosis of BV and examined the utility of creating a BV screening tool using clinical, behavioural and demographic characteristics. A total of 1916 pregnant women were included in this analysis. In total, 757 women screened positive for BV and over one third of BV-positive women presented without any lower genital tract symptoms (39.4%). African American race, abnormal vaginal odour, and smoking were independently related to BV positivity. A BV screening tool including these three factors was fairly predictive of BV status with the area under the ROC curve equal to 0.669. This three-item prediction rule may be useful in identifying high- risk pregnant women in need of BV screening and, given the high specificity, accurately identify the group of BV-negative pregnant women.

  7. Evaluation of Bioinformatic Programmes for the Analysis of Variants within Splice Site Consensus Regions

    PubMed Central

    Tang, Rongying; Prosser, Debra O.; Love, Donald R.

    2016-01-01

    The increasing diagnostic use of gene sequencing has led to an expanding dataset of novel variants that lie within consensus splice junctions. The challenge for diagnostic laboratories is the evaluation of these variants in order to determine if they affect splicing or are merely benign. A common evaluation strategy is to use in silico analysis, and it is here that a number of programmes are available online; however, currently, there are no consensus guidelines on the selection of programmes or protocols to interpret the prediction results. Using a collection of 222 pathogenic mutations and 50 benign polymorphisms, we evaluated the sensitivity and specificity of four in silico programmes in predicting the effect of each variant on splicing. The programmes comprised Human Splice Finder (HSF), Max Entropy Scan (MES), NNSplice, and ASSP. The MES and ASSP programmes gave the highest performance based on Receiver Operator Curve analysis, with an optimal cut-off of score reduction of 10%. The study also showed that the sensitivity of prediction is affected by the level of conservation of individual positions, with in silico predictions for variants at positions −4 and +7 within consensus splice sites being largely uninformative. PMID:27313609

  8. Cerebrospinal fluid lactate: a differential biomarker for bacterial and viral meningitis in children.

    PubMed

    Nazir, Mudasir; Wani, Wasim Ahmad; Malik, Muzaffar Ahmad; Mir, Mohd Rafiq; Ashraf, Younis; Kawoosa, Khalid; Ali, Syed Wajid

    To assess the performance of cerebrospinal fluid (CSF) lactate as a biomarker to differentiate bacterial meningitis from viral meningitis in children, and to define an optimal CSF lactate concentration that can be called significant for the differentiation. Children with clinical findings compatible with meningitis were studied. CSF lactate and other conventional CSF parameters were recorded. At a cut-off value of 3mmol/L, CSF lactate had a sensitivity of 0.90, specificity of 1.0, positive predictive value of 1.0, and negative predictive value of 0.963, with an accuracy of 0.972. The positive and negative likelihood ratios were 23.6 and 0.1, respectively. When comparing between bacterial and viral meningitis, the area under the curve for CSF lactate was 0.979. The authors concluded that CSF lactate has high sensitivity and specificity in differentiating bacterial from viral meningitis. While at a cut-off value of 3mmol/L, CSF lactate has high diagnostic accuracy for bacterial meningitis, mean levels in viral meningitis remain essentially below 2mmol/L. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  9. Parametric study of guided waves dispersion curves for composite plates

    NASA Astrophysics Data System (ADS)

    Predoi, Mihai Valentin; Petre, Cristian Cǎtǎlin; Kettani, Mounsif Ech Cherif El; Leduc, Damien

    2018-02-01

    Nondestructive testing of composite panels benefit from the relatively long range propagation of guided waves in sandwich structures. The guided waves are sensitive to delamination, air bubbles inclusions and cracks and can thus bring information about hidden defects in the composite panel. The preliminary data in all such inspections is represented by the dispersion curves, representing the dependency of the phase/group velocity on the frequency for the propagating modes. In fact, all modes are more or less attenuated, so it is even more important to compute the dispersion curves, which provide also the modal attenuation as function of frequency. Another important aspect is the sensitivity of the dispersion curves on each of the elastic constant of the composite, which are orthotropic in most cases. All these aspects are investigated in the present work, based on our specially developed finite element numerical model implemented in Comsol, which has several advantages over existing methods. The dispersion curves and modal displacements are computed for an example of composite plate. Comparison with literature data validates the accuracy of our results.

  10. Screening of depression in cardiology: A study on 617 cardiovascular patients.

    PubMed

    Tesio, Valentina; Marra, Sebastiano; Molinaro, Stefania; Torta, Riccardo; Gaita, Fiorenzo; Castelli, Lorys

    2017-10-15

    Depression screening in the cardiovascular disease (CVD) care setting is under-performed, also because the issue of the optimal screening tools cut-off is still open. We analysed which HADS (Hospital Anxiety and Depression Scale) total score cut-off value shows the best properties in two groups of 357 Acute Coronary Syndrome (ACS) and 260 Chronic Coronary Artery Disease (CAD) hospitalized patients. A Receiver Operating Characteristics (ROC) curve was plotted for both groups using the Montgomery-Asberg Depression Rating Scale (MADRS) as the criterion. Accuracy, positive (PPV) and negative (NPV) predictive values were computed for different cut-off scores. The ROC curves confirmed the excellent/very good accuracy of the HADS in both groups, with an area under the curve of 0.911 for the ACS and 0.893 for the CAD patients. The cut-off of 14 showed the best compromise between high sensitivity and good specificity in both groups, with high negative predicted values (95.5% and 92.4%, respectively). Using a cut-off value of 14, the HADS could be considered a good screening tool to identify hospitalized CAD and ACS patients requiring a more accurate depression assessment, in order to promptly plan the most appropriate treatment strategies and prevent the negative effects of depression in CVD patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Diagnostic value of serum Golgi protein 73 for HBV-related primary hepatic carcinoma

    PubMed Central

    Gao, Guosheng; Dong, Feibo; Xu, Xiaozhen; Hu, Airong; Hu, Yaoren

    2015-01-01

    Background: Alpha-fetoprotein (AFP) levels are routinely used for diagnosis and monitoring of hepatic diseases, but it has a limited value. Golgi protein 73 (GP73) has been suggested as a new marker for hepatic diseases. Objective: To explore the clinical value of serum GP73 in different diseases associated with hepatitis B virus (HBV) infection. Method: Between January 2010 and August 2014, serum samples from 88 patients with chronic hepatitis B (CHB), 78 patients with HBV-related liver cirrhosis (LC), and 194 patients with HBV-related primary hepatic cancer (PHC) were collected. Serum samples from 30 healthy volunteers were used as controls. ELISA and microparticle enzyme immunoassay were used to measure serum GP73 and AFP levels. Receiver operating characteristic (ROC) curves were used to analyze the diagnostic value of serum GP73 and AFP for PHC. Results: For the diagnosis of PHC, GP73 showed a sensitivity of 65.5% and specificity of 66.3%, while AFP levels showed sensitivity of 64.4% and specificity of 76.5%. Serial testing (both tests are positive) could increase the specificity (sensitivity of 45.9% and specificity of 85.5%) while parallel testing (any single positive test result) could increase the sensitivity (sensitivity of 84.0% and specificity of 57.2%). Serum GP73 and AFP levels were significantly different between Child-Pugh grades (P<0.001 for GP73 and P=0.044 for AFP). Significant differences in serum GP73 and AFP were found between TNM stages (all P<0.001). Conclusion: Serum GP73 had limited diagnostic value for HBV-related PHC. The combined use of serum GP73 and AFP levels improved the diagnostic efficacy. PMID:26617863

  12. Primary care validation of a single screening question for drinkers.

    PubMed

    Seale, J Paul; Boltri, John M; Shellenberger, Sylvia; Velasquez, Mary M; Cornelius, Monica; Guyinn, Monique; Okosun, Ike; Sumner, Heather

    2006-09-01

    The aim of this study was to conduct a primary care validation study of a single screening question for alcohol misuse ("When was the last time you had more than X drinks in 1 day?," where X was four for women and X was five for men), which was previously validated in a study conducted in emergency departments. This cross-sectional study was accomplished by interviewing 625 male and female adult drinkers who presented to five southeastern primary care practices. Patients answered the single question (coded as within 3 months, within 12 months, ever, or never), Alcohol Use Disorders Identification Test (AUDIT), and AUDIT consumption questions (AUDIT-C). Alcohol misuse was defined as either at-risk drinking, identified by a 29-day Timeline Followback interview or a current (past-year) alcohol-use disorder by Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria, or both. Among 625 drinkers interviewed, 25.6% were at-risk drinkers, 21.7% had a current alcohol- use disorder, and 35.2% had either or both conditions. Considering "within the last 3 months" as positive, the sensitivity of the single question was 80% and the specificity was 74%. Chi-square analyses revealed similar sensitivity across ethnic and gender groups; however, specificity was higher in women and whites (p = .0187 and .0421, respectively). Considering "within the last 12 months" as positive increased the question's sensitivity, especially for those with alcohol-use disorders. The area under the receiver operating characteristic curve of the single alcohol screening question (0.79) was slightly lower than for the AUDIT and AUDIT-C, but sensitivity and specificity were similar. A single question about the last episode of heavy drinking is a sensitive, time-efficient screening instrument that shows promise for increasing alcohol screening in primary care practices.

  13. Sensitivity and specificity of fluorescence microlymphography for detecting lymphedema of the lower extremity.

    PubMed

    Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B

    2013-06-01

    Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

  14. Rational Degenerations of M-Curves, Totally Positive Grassmannians and KP2-Solitons

    NASA Astrophysics Data System (ADS)

    Abenda, Simonetta; Grinevich, Petr G.

    2018-03-01

    We establish a new connection between the theory of totally positive Grassmannians and the theory of M-curves using the finite-gap theory for solitons of the KP equation. Here and in the following KP equation denotes the Kadomtsev-Petviashvili 2 equation [see (1)], which is the first flow from the KP hierarchy. We also assume that all KP times are real. We associate to any point of the real totally positive Grassmannian Gr^{tp} (N,M) a reducible curve which is a rational degeneration of an M-curve of minimal genus {g=N(M-N)} , and we reconstruct the real algebraic-geometric data á la Krichever for the underlying real bounded multiline KP soliton solutions. From this construction, it follows that these multiline solitons can be explicitly obtained by degenerating regular real finite-gap solutions corresponding to smooth M-curves. In our approach, we rule the addition of each new rational component to the spectral curve via an elementary Darboux transformation which corresponds to a section of a specific projection Gr^{tp} (r+1,M-N+r+1)\\mapsto Gr^{tp} (r,M-N+r).

  15. Novel, In-House, SYBR Green Based One-Step rRT-PCR: Rapid and Accurate Diagnosis of Crimean-Congo Hemorrhagic Fever Virus in Suspected Patients From Iran.

    PubMed

    Zahraei, Bentolhoda; Hashemzadeh, Mohammad Sadegh; Najarasl, Mohammad; Zahiriyeganeh, Samaneh; Tat, Mahdi; Metanat, Maliheh; Sepehri Rad, Nahid; Khansari-Nejad, Behzad; Zafari, Ehsan; Sharti, Mojtaba; Dorostkar, Ruhollah

    2016-01-01

    The Crimean-Congo hemorrhagic fever (CCHF) virus causes severe disease in humans, with a high mortality rate. Since, there is no approved vaccine or specific treatment for CCHF, an early and accurate diagnosis, as well as reliable surveillance, is essential for case management and patient improvement. For this research, our aim was to evaluate the application of a novel SYBR Green based one-step real-time reverse-transcriptase polymerase chain reaction (rRT-PCR) assay for the in-house diagnosis of the CCHF virus. In this experimental study, the highly conserved S-region sequence of the CCHF viral genome was first adapted from GenBank, and the specific primers targeting this region were designed. Then, the viral RNA was extracted from 75 serum samples from different patients in eastern Iran. The sensitivity and specificity of the primers were also evaluated in positive serum samples previously confirmed to have the CCHF virus, by this one-step rRT-PCR assay, as well as a DNA sequencing analysis. From a total of 75 suspected serum samples, 42 were confirmed to be positive for CCHF virus, with no false-positives detected by the sequencing results. After 40 amplification cycles, the melting curve analysis revealed a mean melting temperature (Tm) of 86.5 ± 0.6°C (quite different from those of the primer-dimers), and the positive samples showed only a small variation in the parameters. In all of the positive samples, the predicted length of 420 bp was confirmed by electrophoresis. Moreover, the sensitivity test showed that this assay can detect less than 20 copies of viral RNA per reaction. This study showed that this novel one-step rRT-PCR assay is a rapid, reliable, repeatable, specific, sensitive, and simple tool for the detection of the CCHF virus.

  16. Effective nucleon mass and the nuclear caloric curve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shetty, D. V.; Souliotis, G. A.; Galanopoulos, S.

    2009-03-15

    Assuming a schematic form of the nucleon effective mass as a function of nuclear excitation energy and mass, we provide a simple explanation for understanding the experimentally observed mass dependence of the nuclear caloric curve. It is observed that the excitation energy at which the caloric curve enters into a plateau region could be sensitive to the nuclear mass evolution of the effective nucleon mass.

  17. Caffeine sensitization of cultured mammalian cells and human lymphocytes irradiated with gamma rays and fast neutrons: a study of relative biological effectiveness in relation to cellular repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannan, M.A.; Gibson, D.P.

    1985-10-01

    The sensitizing effects of caffeine were studied in baby hamster kidney (BHK-21) cells and human lymphocytes following irradiation with gamma rays and fast neutrons. Caffeine sensitization occurred only when log-phase BHK cells and mitogen-stimulated lymphocytes were exposed to the two radiations. Noncycling (confluent) cells of BHK resulted in a shouldered survival curve following gamma irradiation while a biphasic curve was obtained with the log-phase cells. Survival in the case of lymphocytes was estimated by measurement of (TH)thymidine uptake. The relative biological effectiveness (RBE) of fast neutrons was found to be greater at survival levels corresponding to the resistant portions ofmore » the survival curves (shoulder or resistant tail). In both cell types, no reduction in RBE was observed when caffeine was present, because caffeine affected both gamma and neutron survival by the same proportion.« less

  18. Curved butterfly bileaflet prosthetic cardiac valve

    DOEpatents

    McQueen, David M.; Peskin, Charles S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  19. Clinical value of serum anti-mullerian hormone and inhibin B in prediction of ovarian response in patients with polycystic ovary syndrome.

    PubMed

    Zhang, Fan; Liu, Xiao-Ling; Rong, Nan; Huang, Xiao-Wen

    2017-02-01

    The present study aimed to investigate the clinical value of serum anti-mullerian hormone (AMH) and inhibin B (INHB) in predicting the ovarian response of patients with polycystic ovary syndrome (PCOS). A total of 120 PCOS patients were enrolled and divided into three groups in terms of the ovarian response: a low-response group (n=36), a normal-response group (n=44), and a high-response group (n=40). The serum AMH and INHB levels were measured by enzyme-linked immunosorbent assay (ELISA). The follicle stimulating hormone (FSH), luteinizing hormone (LH), and estradiol (E2) levels were determined by chemiluminescence microparticle immunoassay. The correlation of the serum AMH and INHB levels with other indicators was analyzed. A receiver operating characteristic (ROC) curve was established to analyze the prediction of ovarian response by AMH and INHB. The results showed that there were significant differences in age, body mass index (BMI), FSH, total gonadotropin-releasing hormone (GnRH), LH, E2, and antral follicle counts (AFCs) between the groups (P<0.05). The serum AMH and INHB levels were increased significantly with the ovarian response of PCOS patients increasing (P<0.05). The serum AMH and INHB levels were negatively correlated with the age, BMI, FSH level, Gn, and E2 levels (P<0.05). They were positively correlated with the LH levels and AFCs (P<0.05). ROC curve analysis of serum AMH and INHB in prediction of a low ovarian response showed that the area under the ROC curve (AUC) value of the serum AMH level was 0.817, with a cut-off value of 1.29 ng/mL. The sensitivity and specificity were 71.2% and 79.6%, respectively. The AUC value of serum INHB was 0.674, with a cut-off value of 38.65 ng/mL, and the sensitivity and specificity were 50.7% and 74.5%, respectively. ROC curve analysis showed when the serum AMH and INHB levels were used to predict a high ovarian response, the AUC value of the serum AMH level was 0.742, with a cut-off value of 2.84 ng/mL, and the sensitivity and specificity were 72.7% and 65.9%, respectively; the AUC value of the serum INHB level was 0.551 with a cut-off of 45.76 ng/mL, and the sensitivity and specificity were 76.3% and 40.2%, respectively. It was suggested the serum AMH and INHB levels have high clinical value in predicting the ovarian response of PCOS patients.

  20. Impact of fixation artifacts and threshold selection on high resolution melting analysis for KRAS mutation screening.

    PubMed

    Pérez-Báez, Wendy; García-Latorre, Ethel A; Maldonado-Martínez, Héctor Aquiles; Coronado-Martínez, Iris; Flores-García, Leonardo; Taja-Chayeb, Lucía

    2017-10-01

    Treatment in metastatic colorectal cancer (mCRC) has expanded with monoclonal antibodies targeting epidermal growth factor receptor, but is restricted to patients with a wild-type (WT) KRAS mutational status. The most sensitive assays for KRAS mutation detection in formalin-fixed paraffin embedded (FFPE) tissues are based on real-time PCR. Among them, high resolution melting analysis (HRMA), is a simple, fast, highly sensitive, specific and cost-effective method, proposed as adjunct for KRAS mutation detection. However the method to categorize WT vs mutant sequences in HRMA is not clearly specified in available studies, besides the impact of FFPE artifacts on HRMA performance hasn't been addressed either. Avowedly adequate samples from 104 consecutive mCRC patients were tested for KRAS mutations by Therascreen™ (FDA Validated test), HRMA, and HRMA with UDG pre-treatment to reverse FFPE fixation artifacts. Comparisons of KRAS status allocation among the three methods were done. Focusing on HRMA as screening test, ROC curve analyses were performed for HRMA and HMRA-UDG against Therascreen™, in order to evaluate their discriminative power and to determine the threshold of profile concordance between WT control and sample for KRAS status determination. Comparing HRMA and HRMA-UDG against Therascreen™ as surrogate gold standard, sensitivity was 1 for both HRMA and HRMA-UDG; and specificity and positive predictive values were respectively 0.838 and 0.939; and 0.777 and 0.913. As evaluated by the McNemar test, HRMA-UDG allocated samples to a WT/mutated genotype in a significatively different way from HRMA (p > 0.001). On the other hand HRMA-UDG did not differ from Therascreen™ (p = 0.125). ROC-curve analysis showed a significant discriminative power for both HRMA and HRMA-UDG against Therascreen™ (respectively, AUC of 0.978, p > 0.0001, CI 95% 0.957-0.999; and AUC of 0.98, p > 0.0001, CI 95% 0.000-1.0). For HRMA as a screening tool, the best threshold (degree of concordance between sample curves and WT control) was attained at 92.14% for HRMA (specificity of 0.887), and at 92.55% for HRMA-UDG (specificity of 0.952). HRMA is a highly sensitive method for KRAS mutation detection, with apparently adequate and statistically significant discriminative power. FFPE sample fixation artifacts have an impact on HRMA results, so for HRMA on FFPE samples pre-treatment with UDG should be strongly suggested. The choice of the threshold for melting curve concordance has also great impact on HRMA performance. A threshold of 93% or greater might be adequate if using HRMA as a screening tool. Further validation of this threshold is required. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Preoperative cow-side lactatemia measurement predicts negative outcome in Holstein dairy cattle with right abomasal disorders.

    PubMed

    Boulay, G; Francoz, D; Doré, E; Dufour, S; Veillette, M; Badillo, M; Bélanger, A-M; Buczinski, S

    2014-01-01

    The objectives of the current study were (1) to determine the gain in prognostic accuracy of preoperative l-lactate concentration (LAC) measured on farm on cows with right displaced abomasum (RDA) or abomasal volvulus (AV) for predicting negative outcome; and (2) to suggest clinically relevant thresholds for such use. A cohort of 102 cows with on-farm surgical diagnostic of RDA or AV was obtained from June 2009 through December 2011. Blood was drawn from coccygeal vessels before surgery and plasma LAC was immediately measured by using a portable clinical analyzer. Dairy producers were interviewed by phone 30 d following surgery and the outcome was determined: a positive outcome if the owner was satisfied of the overall evolution 30 d postoperatively, and a negative outcome if the cow was culled, died, or if the owner reported being unsatisfied 30 d postoperatively. The area under the curve of the receiver operating characteristic curve for LAC was 0.92 and was significantly greater than the area under the curve of the receiver operating characteristic curve of heart rate (HR; 0.77), indicating that LAC, in general, performed better than HR to predict a negative outcome. Furthermore, the ability to predict a negative outcome was significantly improved when LAC measurement was considered in addition to the already available HR data (area under the curve: 0.93 and 95% confidence interval: 0.87, 0.99). Important inflection points of the misclassification cost term function were noted at thresholds of 2 and 6 mmol/L, suggesting the potential utility of these cut-points. The 2 and 6 mmol/L thresholds had a sensitivity, specificity, positive predictive value, and negative predictive value for predicting a negative outcome of 76.2, 82.7, 53.3, and 93.1%, and of 28.6, 97.5, 75, and 84%, respectively. In terms of clinical interpretation, LAC ≤2 mmol/L appeared to be a good indicator of positive outcome and could be used to support a surgical treatment decision. The treatment decision for cows with LAC between 2 and 6 mmol/L, however, would depend on the economic context and the owner's attitude to risk in regard to potential return on its investment. Finally, performing a surgical correction on commercial cows with RDA or AV and a LAC ≥6 mmol/L appeared to be unjustified and these animals should be culled based on their high probability of negative outcome. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Psychobiological Influences on Maternal Sensitivity in the Context of Adversity

    PubMed Central

    Finegood, Eric D.; Blair, Clancy; Granger, Douglas A.; Hibel, Leah C.; Mills-Koonce, Roger

    2016-01-01

    This study evaluated prospective longitudinal relations among an index of poverty-related cumulative risk, maternal salivary cortisol, child negative affect, and maternal sensitivity across the first two postpartum years. Participants included 1,180 biological mothers residing in rural and predominantly low-income communities in the US. Multilevel growth curve analyses indicated that an index of cumulative risk was positively associated with maternal cortisol across the postpartum (study visits occurring at approximately 7, 15, and 24 months postpartum) over and above effects for African American ethnicity, time of day of saliva collection, age, parity status, having given birth to another child, contraceptive use, tobacco smoking, body mass index, and breastfeeding. Consistent with a psychobiological theory of mothering, maternal salivary cortisol was negatively associated with maternal sensitivity observed during parent-child interactions across the first two postpartum years over and above effects for poverty-related cumulative risk, child negative affect, as well as a large number of covariates associated with cortisol and maternal sensitivity. Child negative affect expressed during parent-child interactions was negatively associated with observed maternal sensitivity at late (24 months) but not early time points of observation (7 months) and cumulative risk was negatively associated with maternal sensitivity across the postpartum and this effect strengthened over time. Results advance our understanding of the dynamic, transactional, and psychobiological influences on parental caregiving behaviors across the first two postpartum years. PMID:27337514

  3. Circulating human papillomavirus DNA as a surveillance tool in head and neck squamous cell carcinoma: a systematic review and meta-analysis.

    PubMed

    Jensen, Kristina Kvist; Grønhøj, Christian; Jensen, David H; von Buchwald, Christian

    2018-05-15

    The incidence of human papillomavirus-induced (HPV+) head and neck squamous cell carcinoma (HNSCC) i.e. especially oropharyngeal cancers (OPSCC) is increasing and a significant proportion of patients encounter disease progression. A simple and sensitive test to identify patients with progression is an unmet need. To systematically review the literature and carry out a meta-analysis of studies, investigated circulating HPV-DNA as a biomarker for disease progression in patients with HNSCC. A systematic review and meta-analysis. PubMed, Embase and the Cochrane Library were systematically searched for articles published in English from January 1980 to November 2017. Search terms used were related to HPV, cancer sites, blood-based biomarkers and terms for specific use settings. Articles reviewed and selected by authors and data on study design, demographic variables, location, HPV status, number of pre treatment blood tests, number of post treatment blood tests, blood HPV status and number of recurrences and length of follow-up was extracted. A meta-analysis of HPV-DNA as a diagnostic test for recurrence by means of a hierarchical summary receiver operating curve (HSROC) model was performed. We identified five studies (n=600 subjects) examining circulating HPV-DNA in patients with HNSCC. In these five studies (n=411) patients had both pre and post treatment blood samples. The pooled sensitivity, in detecting a recurrence was estimated to be 54% (95% CI: 32%-74%), while the pooled specificity was 98% (95% CI: 93-99.4%). The pooled false-positive rate is 2% (95% CI: 0.6%-7%). The area under the curve (AUC) of the summary HSROC was 0.93. Positive predictive value was estimated to 93% and the negative predictive value to 94%. Plasma HPV-DNA is a promising tool for surveillance in patients with HPV-related HNSCC i.e. OPSCC and has a high specificity. By recent technical advances and by increasing follow-up blood samples the sensitivity could likely be improved. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Development of a predictive model to identify inpatients at risk of re-admission within 30 days of discharge (PARR-30)

    PubMed Central

    Billings, John; Blunt, Ian; Steventon, Adam; Georghiou, Theo; Lewis, Geraint; Bardsley, Martin

    2012-01-01

    Objectives To develop an algorithm for identifying inpatients at high risk of re-admission to a National Health Service (NHS) hospital in England within 30 days of discharge using information that can either be obtained from hospital information systems or from the patient and their notes. Design Multivariate statistical analysis of routinely collected hospital episode statistics (HES) data using logistic regression to build the predictive model. The model's performance was calculated using bootstrapping. Setting HES data covering all NHS hospital admissions in England. Participants The NHS patients were admitted to hospital between April 2008 and March 2009 (10% sample of all admissions, n=576 868). Main outcome measures Area under the receiver operating characteristic curve for the algorithm, together with its positive predictive value and sensitivity for a range of risk score thresholds. Results The algorithm produces a ‘risk score’ ranging (0–1) for each admitted patient, and the percentage of patients with a re-admission within 30 days and the mean re-admission costs of all patients are provided for 20 risk bands. At a risk score threshold of 0.5, the positive predictive value (ie, percentage of inpatients identified as high risk who were subsequently re-admitted within 30 days) was 59.2% (95% CI 58.0% to 60.5%); representing 5.4% (95% CI 5.2% to 5.6%) of all inpatients who would be re-admitted within 30 days (sensitivity). The area under the receiver operating characteristic curve was 0.70 (95% CI 0.69 to 0.70). Conclusions We have developed a method of identifying inpatients at high risk of unplanned re-admission to NHS hospitals within 30 days of discharge. Though the models had a low sensitivity, we show how to identify subgroups of patients that contain a high proportion of patients who will be re-admitted within 30 days. Additional work is necessary to validate the model in practice. PMID:22885591

  5. Usefulness of DWI in preoperative assessment of deep myometrial invasion in patients with endometrial carcinoma: a systematic review and meta-analysis

    PubMed Central

    2014-01-01

    Background The objective of this study was to perform a systematic review and a meta-analysis in order to estimate the diagnostic accuracy of diffusion weighted imaging (DWI) in the preoperative assessment of deep myometrial invasion in patients with endometrial carcinoma. Methods Studies evaluating DWI for the detection of deep myometrial invasion in patients with endometrial carcinoma were systematically searched for in the MEDLINE, EMBASE, and Cochrane Library from January 1995 to January 2014. Methodologic quality was assessed by using the Quality Assessment of Diagnostic Accuracy Studies tool. Bivariate random-effects meta-analytic methods were used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR) and receiver operating characteristic (ROC) curves. The study also evaluated the clinical utility of DWI in preoperative assessment of deep myometrial invasion. Results Seven studies enrolling a total of 320 individuals met the study inclusion criteria. The summary area under the ROC curve was 0.91. There was no evidence of publication bias (P = 0.90, bias coefficient analysis). Sensitivity and specificity of DWI for detection of deep myometrial invasion across all studies were 0.90 and 0.89, respectively. Positive and negative likelihood ratios with DWI were 8 and 0.11 respectively. In patients with high pre-test probabilities, DWI enabled confirmation of deep myometrial invasion; in patients with low pre-test probabilities, DWI enabled exclusion of deep myometrial invasion. The worst case scenario (pre-test probability, 50%) post-test probabilities were 89% and 10% for positive and negative DWI results, respectively. Conclusion DWI has high sensitivity and specificity for detecting deep myometrial invasion and more importantly can reliably rule out deep myometrial invasion. Therefore, it would be worthwhile to add a DWI sequence to the standard MRI protocols in preoperative evaluation of endometrial cancer in order to detect deep myometrial invasion, which along with other poor prognostic factors like age, tumor grade, and LVSI would be useful in stratifying high risk groups thereby helping in the tailoring of surgical approach in patient with low risk of endometrial carcinoma. PMID:25608571

  6. Monitoring food pathogens: Novel instrumentation for cassette PCR testing

    PubMed Central

    Hunt, Darin; Figley, Curtis; Lauzon, Jana; Figley, Rachel; Pilarski, Linda M.; McMullen, Lynn M.; Pilarski, Patrick M.

    2018-01-01

    In this manuscript, we report the design and development of a fast, reliable instrument to run gel-based cassette polymerase chain reactions (PCR). Here termed the GelCycler Mark II, our instrument is a miniaturized molecular testing system that is fast, low cost and sensitive. Cassette PCR utilizes capillary reaction units that carry all reagents needed for PCR, including primers and Taq polymerase, except the sample, which is loaded at the time of testing. Cassette PCR carries out real time quantitative PCR followed by melt curve analysis (MCA) to verify amplicon identity at the expected melt temperature (Tm). The cassette PCR technology is well developed, particularly for detecting pathogens, and has been rigorously validated for detecting pathogenic Escherichia coli in meat samples. However, the work has been hindered by the lack of a robust and stable instrument to carry out the PCR, which requires fast and accurate temperature regulation, improved light delivery and fluorescent recording, and faster PCR reactions that maintain a high sensitivity of detection. Here, we report design and testing of a new instrument to address these shortcomings and to enable standardized testing by cassette PCR and commercial manufacture of a robust and accurate instrument that can be mass produced to deliver consistent performance. As a corollary to our new instrument development, we also report the use of an improved design approach using a machined aluminum cassette to meet the new instrument standards, prevent any light bleed across different trenches in each cassette, and allow testing of a larger number of samples for more targets in a single run. The GelCycler Mark II can detect and report E. coli contamination in 41 minutes. Sample positives are defined in as having a melt curve comparable to the internal positive control, with peak height exceeding that of the internal negative control. In a fractional analysis, as little as 1 bacterium per capillary reaction unit is directly detectable, with no enrichment step, in 35 cycles of PCR/MCA, in a total time of 53 minutes, making this instrument and technology among the very best for speed and sensitivity in screening food for pathogenic contamination. PMID:29746561

  7. Automated Optimization of Potential Parameters

    PubMed Central

    Michele, Di Pierro; Ron, Elber

    2013-01-01

    An algorithm and software to refine parameters of empirical energy functions according to condensed phase experimental measurements are discussed. The algorithm is based on sensitivity analysis and local minimization of the differences between experiment and simulation as a function of potential parameters. It is illustrated for a toy problem of alanine dipeptide and is applied to folding of the peptide WAAAH. The helix fraction is highly sensitive to the potential parameters while the slope of the melting curve is not. The sensitivity variations make it difficult to satisfy both observations simultaneously. We conjecture that there is no set of parameters that reproduces experimental melting curves of short peptides that are modeled with the usual functional form of a force field. PMID:24015115

  8. Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies.

    PubMed

    Freitas, F G R; Bafi, A T; Nascente, A P M; Assunção, M; Mazza, B; Azevedo, L C P; Machado, F R

    2013-03-01

    The applicability of pulse pressure variation (ΔPP) to predict fluid responsiveness using lung-protective ventilation strategies is uncertain in clinical practice. We designed this study to evaluate the accuracy of this parameter in predicting the fluid responsiveness of septic patients ventilated with low tidal volumes (TV) (6 ml kg(-1)). Forty patients after the resuscitation phase of severe sepsis and septic shock who were mechanically ventilated with 6 ml kg(-1) were included. The ΔPP was obtained automatically at baseline and after a standardized fluid challenge (7 ml kg(-1)). Patients whose cardiac output increased by more than 15% were considered fluid responders. The predictive values of ΔPP and static variables [right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP)] were evaluated through a receiver operating characteristic (ROC) curve analysis. Thirty-four patients had characteristics consistent with acute lung injury or acute respiratory distress syndrome and were ventilated with high levels of PEEP [median (inter-quartile range) 10.0 (10.0-13.5)]. Nineteen patients were considered fluid responders. The RAP and PAOP significantly increased, and ΔPP significantly decreased after volume expansion. The ΔPP performance [ROC curve area: 0.91 (0.82-1.0)] was better than that of the RAP [ROC curve area: 0.73 (0.59-0.90)] and pulmonary artery occlusion pressure [ROC curve area: 0.58 (0.40-0.76)]. The ROC curve analysis revealed that the best cut-off for ΔPP was 6.5%, with a sensitivity of 0.89, specificity of 0.90, positive predictive value of 0.89, and negative predictive value of 0.90. Automatized ΔPP accurately predicted fluid responsiveness in septic patients ventilated with low TV.

  9. LMS tables for waist circumference and waist–height ratio in Colombian adults: analysis of nationwide data 2010

    PubMed Central

    Ramírez-Vélez, R; Correa-Bautista, J E; Martínez-Torres, J; Méneses-Echavez, J F; González-Ruiz, K; González-Jiménez, E; Schmidt-RioValle, J; Lobelo, F

    2016-01-01

    Background/Objectives: Indices predictive of central obesity include waist circumference (WC) and waist-to-height ratio (WHtR). These data are lacking for Colombian adults. This study aims at establishing smoothed centile charts and LMS tables for WC and WHtR; appropriate cutoffs were selected using receiver-operating characteristic analysis based on data from the representative sample. Subjects/Methods: We used data from the cross-sectional, national representative nutrition survey (ENSIN, 2010). A total of 83 220 participants (aged 20–64) were enroled. Weight, height, body mass index (BMI), WC and WHtR were measured and percentiles calculated using the LMS method (L (curve Box-Cox), M (curve median), and S (curve coefficient of variation)). Receiver operating characteristics curve analyses were used to evaluate the optimal cutoff point of WC and WHtR for overweight and obesity based on WHO definitions. Results: Reference values for WC and WHtR are presented. Mean WC and WHtR increased with age for both genders. We found a strong positive correlation between WC and BMI (r=0.847, P< 0.01) and WHtR and BMI (r=0.878, P<0.01). In obese men, the cutoff point value is 96.6 cm for the WC. In women, the cutoff point value is 91.0 cm for the WC. Receiver operating characteristic curve for WHtR was also obtained and the cutoff point value of 0.579 in men, and in women the cutoff point value was 0.587. A high sensitivity and specificity were obtained. Conclusions: This study presents first reference values of WC and WHtR for Colombians aged 20–64. Through LMS tables for adults, we hope to provide quantitative tools to study obesity and its complications. PMID:27026425

  10. Cognitive influences on risk-seeking by rhesus macaques

    PubMed Central

    Hayden, Benjamin Y.; Heilbronner, Sarah R.; Nair, Amrita C.; Platt, Michael L.

    2009-01-01

    Humans and other animals are idiosyncratically sensitive to risk, either preferring or avoiding options having the same value but differing in uncertainty. Many explanations for risk sensitivity rely on the non-linear shape of a hypothesized utility curve. Because such models do not place any importance on uncertainty per se, utility curve-based accounts predict indifference between risky and riskless options that offer the same distribution of rewards. Here we show that monkeys strongly prefer uncertain gambles to alternating rewards with the same payoffs, demonstrating that uncertainty itself contributes to the appeal of risky options. Based on prior observations, we hypothesized that the appeal of the risky option is enhanced by the salience of the potential jackpot. To test this, we subtly manipulated payoffs in a second gambling task. We found that monkeys are more sensitive to small changes in the size of the large reward than to equivalent changes in the size of the small reward, indicating that they attend preferentially to the jackpots. Together, these results challenge utility curve-based accounts of risk sensitivity, and suggest that psychological factors, such as outcome salience and uncertainty itself, contribute to risky decision-making. PMID:19844596

  11. On the reduction of occultation light curves. [stellar occultations by planets

    NASA Technical Reports Server (NTRS)

    Wasserman, L.; Veverka, J.

    1973-01-01

    The two basic methods of reducing occultation light curves - curve fitting and inversion - are reviewed and compared. It is shown that the curve fitting methods have severe problems of nonuniqueness. In addition, in the case of occultation curves dominated by spikes, it is not clear that such solutions are meaningful. The inversion method does not suffer from these drawbacks. Methods of deriving temperature profiles from refractivity profiles are then examined. It is shown that, although the temperature profiles are sensitive to small errors in the refractivity profile, accurate temperatures can be obtained, particularly at the deeper levels of the atmosphere. The ambiguities that arise when the occultation curve straddles the turbopause are briefly discussed.

  12. Evolution of sensitivity to fosfomycin in bacteria isolated in 1973, 1974 and 1975 in the Servicio de Microbiologia y Epidemiologia of the 'Clinica Puerta de Hierro', Madrid.

    PubMed

    Dámaso, D; Moreno-López, M; Martínez-Beltrán, J

    1977-01-01

    The bacteriostatic activity of fosfomycin was studied in vitro against 1,243 clinical isolations of gram-positive cocci and 4,086 isolations of gram-negative bacilli that were obtained in 1973, 1974 and in the period from January to May of 1975. MIC was determined by the agar diffusion method, quantifying it by means of the standard curve that was worked out with the strain of E. coli NCTC 10,418. A slight increase in resistance was observed in the gram-positive cocci: 64 mug/ml were inhibitory for 63% of the 249 isolations obtained in 1973, 59.1% of the 716 isolations obtained in 1974, and 57.5% of the 278 isolations from 1975. A slight loss of sensitivity was also observed in the gram-negative bacilli: the aforementioned concentration of fosfomycin inhibited 36% of the 742 isolations from 1973, 33.6% of the 2,387 isolations from 1974 and 32.6% of the 957 isolations from 1975. 933 g of this antibiotic were consumed in our hospital in 1973, 4,203 g in 1974 and 957 g in 1975. The consumption rate per patient per year was 0.15, 0.72 and 0.20 g, respectively. In conclusion, although no change was observed in the sensitivity of some bacterial strains to fosfomycin, the overall study indicates a slight decrease in the sensitivity, although it does not apparently have any relationship to the consumption of fosfomycin in our hospital.

  13. The Albedo of Kepler's Small Worlds

    NASA Astrophysics Data System (ADS)

    Jansen, Tiffany; Kipping, David

    2018-01-01

    The study of exoplanet phase curves has been established as a powerful tool for measuring the atmospheric properties of other worlds. To first order, phase curves have the same amplitude as occultations, yet far greater temporal baselines enabling substantial improvements in sensitivity. Even so, only a relatively small fraction of Kepler planets have detectable phase curves, leading to a population dominated by hot-Jupiters. One way to boost sensitivity further is to stack different planets of similar types together, giving rise to an average phase curve for a specific ensemble. In this work, we measure the average albedo, thermal redistribution efficiency, and greenhouse boosting factor from the average phase curves of 115 Neptunian and 50 Terran (solid) worlds. We construct ensemble phase curve models for both samples accounting for the reflection and thermal components and regress our models assuming a global albedo, redistribution factor and greenhouse factor in a Bayesian framework. We find modest evidence for a detected phase curve in the Neptunian sample, although the albedo and thermal properties are somewhat degenerate meaning we can only place an upper limit on the albedo of Ag < 0.23 and greenhouse factor of f < 1.40 to 95% confidence. As predicted theoretically, this confirms hot-Neptunes are darker than Neptune and Uranus. Additionally, we place a constraint on the albedo of solid, Terran worlds of Ag < 0.42 and f < 1.60 to 95% confidence, compatible with a dark Lunar-like surface.

  14. Sensitivity tests and ensemble hazard assessment for tephra fallout at Campi Flegrei, Italy

    NASA Astrophysics Data System (ADS)

    Selva, Jacopo; Costa, Antonio; De Natale, Giuseppe; Di Vito, Mauro; Isaia, Roberto; Macedonio, Giovanni

    2017-04-01

    We present the results of a statistical study on tephra dispersion in the case of reactivation of the Campi Flegrei volcano. We considered the full spectrum of possible eruptions, in terms of size and position of eruptive vents. To represent the spectrum of possible eruptive sizes, four classes of eruptions were considered. Of those only three are explosive (small, medium, and large) and can produce a significant quantity of volcanic ash. Hazard assessments are made through dispersion simulations of ash and lapilli, considering the full variability of winds, eruptive vents, and eruptive sizes. The results are presented in form of four families of hazard curves conditioned to the occurrence of an eruption: 1) small eruptive size from any vent; 2) medium eruptive size from any vent; 3) large eruptive size from any vent; 4) any size from any vent. The epistemic uncertainty (i.e. associated with the level of scientific knowledge of phenomena) on the estimation of hazard curves was quantified making use of alternative scientifically acceptable approaches. The choice of such alternative models is made after a comprehensive sensitivity analysis which considered different weather databases, alternative modelling of the possible opening of eruptive vents, tephra total grain-size distributions (TGSD), relative mass of fine particles, and the effect of aggregation. The results of this sensitivity analyses show that the dominant uncertainty is related to the choice of TGSD, mass of fine ash, and potential effects of ash aggregation. The latter is particularly relevant in case of magma-water interaction during an eruptive phase, when most of the fine ash can form accretionary lapilli that could contribute significantly in increasing the tephra load in the proximal region. Relatively insignificant is the variability induced by the use of different weather databases. The hazard curves, together with the quantification of epistemic uncertainty, were finally calculated through a statistical model based on ensemble mixing of selected alternative models, e.g. different choices on the estimate of the total erupted mass, mass of fine ash, effects of aggregation, etc. Hazard and probability maps were produced at different confidence levels compared to the epistemic uncertainty (mean, median, 16th percentile, and 84th percentile).

  15. Preoperative Magnetic Resonance Volumetry in Predicting Myometrial Invasion, Lymphovascular Space Invasion, and Tumor Grade: Is It Valuable in International Federation of Gynecology and Obstetrics Stage I Endometrial Cancer?

    PubMed

    Sahin, Hilal; Sarioglu, Fatma Ceren; Bagci, Mustafa; Karadeniz, Tugba; Uluer, Hatice; Sanci, Muzaffer

    2018-05-01

    The aim of this retrospective single-center study was to evaluate the relationship between maximum tumor size, tumor volume, tumor volume ratio (TVR) based on preoperative magnetic resonance (MR) volumetry, and negative histological prognostic parameters (deep myometrial invasion [MI], lymphovascular space invasion, tumor histological grade, and subtype) in International Federation of Gynecology and Obstetrics stage I endometrial cancer. Preoperative pelvic MR imaging studies of 68 women with surgical-pathologic diagnosis of International Federation of Gynecology and Obstetrics stage I endometrial cancer were reviewed for assessment of MR volumetry and qualitative assessment of MI. Volume of the tumor and uterus was measured with manual tracing of each section on sagittal T2-weighted images. Tumor volume ratio was calculated according to the following formula: TVR = (total tumor volume/total uterine volume) × 100. Receiver operating characteristics curve was performed to investigate a threshold for TVR associated with MI. The Mann-Whitney U test, Kruskal-Wallis test, and linear regression analysis were applied to evaluate possible differences between tumor size, tumor volume, TVR, and negative prognostic parameters. Receiver operating characteristics curve analysis of TVR for prediction of deep MI was statistically significant (P = 0.013). An optimal TVR threshold of 7.3% predicted deep myometrial invasion with 85.7% sensitivity, 46.8% specificity, 41.9% positive predictive value, and 88.0% negative predictive value. Receiver operating characteristics curve analyses of TVR, tumor size, and tumor volume for prediction of tumor histological grade or lymphovascular space invasion were not significant. The concordance between radiologic and pathologic assessment for MI was almost excellent (κ value, 0.799; P < 0.001). Addition of TVR to standard radiologic assessment of deep MI increased the sensitivity from 90.5% to 95.2%. Tumor volume ratio, based on preoperative MR volumetry, seems to predict deep MI independently in stage I endometrial cancer with insufficient sensitivity and specificity. Its value in clinical practice for risk stratification models in endometrial cancer has to be studied in larger cohort of patients.

  16. Study on phase noise induced by 1/f noise of the modulator drive circuit in high-sensitivity fiber optic gyroscope

    NASA Astrophysics Data System (ADS)

    Teng, Fei; Jin, Jing; Li, Yong; Zhang, Chunxi

    2018-05-01

    The contribution of modulator drive circuit noise as a 1/f noise source to the output noise of the high-sensitivity interferometric fiber optic gyroscope (IFOG) was studied here. A noise model of closed-loop IFOG was built. By applying the simulated 1/f noise sequence into the model, a gyroscope output data series was acquired, and the corresponding power spectrum density (PSD) and the Allan variance curve were calculated to analyze the noise characteristic. The PSD curve was in the spectral shape of 1/f, which verifies that the modulator drive circuit induced a low frequency 1/f phase noise into the gyroscope. The random walk coefficient (RWC), a standard metric to characterize the noise performance of the IFOG, was calculated according to the Allan variance curve. Using an operational amplifier with an input 1/f noise of 520 nV/√Hz at 1 Hz, the RWC induced by this 1/f noise was 2 × 10-4°/√h, which accounts for 63% of the total RWC. To verify the correctness of the noise model we proposed, a high-sensitivity gyroscope prototype was built and tested. The simulated Allan variance curve gave a good rendition of the prototype actual measured curve. The error percentage between the simulated RWC and the measured value was less than 13%. According to the model, a noise reduction method is proposed and the effectiveness is verified by the experiment.

  17. Individual Differences in Subjective Utility and Risk Preferences: The Influence of Hedonic Capacity and Trait Anxiety

    PubMed Central

    Howlett, Jonathon R.; Paulus, Martin P.

    2017-01-01

    Individual differences in decision-making are important in both normal populations and psychiatric conditions. Variability in decision-making could be mediated by different subjective utilities or by other processes. For example, while traditional economic accounts attribute risk aversion to a concave subjective utility curve, in practice other factors could affect risk behavior. This distinction may have important implications for understanding the biological basis of variability in decision-making and for developing interventions to improve decision-making. Another aspect of decision-making that may vary between individuals is the sensitivity of subjective utility to counterfactual outcomes (outcomes that could have occurred, but did not). We investigated decision-making in relation to hedonic capacity and trait anxiety, two traits that relate to psychiatric conditions but also vary in the general population. Subjects performed a decision-making task, in which they chose between low- and high-risk gambles to win 0, 20, or 40 points on each trial. Subjects then rated satisfaction after each outcome on a visual analog scale, indicating subjective utility. Hedonic capacity was positively associated with the subjective utility of winning 20 points but was not associated with the concavity of the subjective utility curve (constructed using the mean subjective utility of winning 0, 20, or 40 points). Consistent with economic theory, concavity of the subjective utility curve was associated with risk aversion. Hedonic capacity was independently associated with risk seeking (i.e., not mediated by the shape of the subjective utility curve), while trait anxiety was unrelated to risk preferences. Contrary to our expectations, counterfactual sensitivity was unrelated to hedonic capacity and trait anxiety. Nevertheless, trait anxiety was associated with a self-report measure of regret-proneness, suggesting that counterfactual influences may occur via a pathway that is separate from immediate counterfactual processing biases. Taken together, our results show that hedonic capacity but not trait anxiety affects risk-taking through a mechanism that appears independent of the shape of the subjective utility curve, while hedonic capacity and trait anxiety do not affect the influence of counterfactual outcomes on subjective utility. The results have implications for understanding the underlying mechanisms of variable decision-making and for developing interventions to improve decision-making. PMID:28588508

  18. Individual Differences in Subjective Utility and Risk Preferences: The Influence of Hedonic Capacity and Trait Anxiety.

    PubMed

    Howlett, Jonathon R; Paulus, Martin P

    2017-01-01

    Individual differences in decision-making are important in both normal populations and psychiatric conditions. Variability in decision-making could be mediated by different subjective utilities or by other processes. For example, while traditional economic accounts attribute risk aversion to a concave subjective utility curve, in practice other factors could affect risk behavior. This distinction may have important implications for understanding the biological basis of variability in decision-making and for developing interventions to improve decision-making. Another aspect of decision-making that may vary between individuals is the sensitivity of subjective utility to counterfactual outcomes (outcomes that could have occurred, but did not). We investigated decision-making in relation to hedonic capacity and trait anxiety, two traits that relate to psychiatric conditions but also vary in the general population. Subjects performed a decision-making task, in which they chose between low- and high-risk gambles to win 0, 20, or 40 points on each trial. Subjects then rated satisfaction after each outcome on a visual analog scale, indicating subjective utility. Hedonic capacity was positively associated with the subjective utility of winning 20 points but was not associated with the concavity of the subjective utility curve (constructed using the mean subjective utility of winning 0, 20, or 40 points). Consistent with economic theory, concavity of the subjective utility curve was associated with risk aversion. Hedonic capacity was independently associated with risk seeking (i.e., not mediated by the shape of the subjective utility curve), while trait anxiety was unrelated to risk preferences. Contrary to our expectations, counterfactual sensitivity was unrelated to hedonic capacity and trait anxiety. Nevertheless, trait anxiety was associated with a self-report measure of regret-proneness, suggesting that counterfactual influences may occur via a pathway that is separate from immediate counterfactual processing biases. Taken together, our results show that hedonic capacity but not trait anxiety affects risk-taking through a mechanism that appears independent of the shape of the subjective utility curve, while hedonic capacity and trait anxiety do not affect the influence of counterfactual outcomes on subjective utility. The results have implications for understanding the underlying mechanisms of variable decision-making and for developing interventions to improve decision-making.

  19. Quantitative assessment of hit detection and confirmation in single and duplicate high-throughput screenings.

    PubMed

    Wu, Zhijin; Liu, Dongmei; Sui, Yunxia

    2008-02-01

    The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.

  20. [The value of B7-H4 and carcinoembryonic antigen in diagnosing the benign and malignant pleural effusion].

    PubMed

    Wei, F; Wei, Y; Li, L F; Li, G L; Wang, G J

    2017-07-23

    Objective: To evaluate the value of combined detection of negative costimulatory molecule B7-H4 and carcinoembryonic antigen (CEA) in diagnosing malignant and benign pleural effusion. Methods: Ninety-seven pleural effusion specimen were collected, 55 of which were diagnosed as malignant pleural effusion and 42 were benign pleural effusion. Enzyme-linked immunosorbent assay(ELISA) was used to examine the concentration of B7-H4 and CEA in pleural effusion. Electro-chemiluminescence immunoassay was used to detect the CEA level in pleural effusion. Receiver operating characteristic (ROC) curve was established to analyze and evaluate the single or combined detection of B7-H4 and CEA in diagnosing malignant and benign pleural effusion. Results: The concentrations of B7-H4 and CEA in malignant pleural effusion (MPE) group were (60.08±35.04) ng/ml and (41.49±37.16) ng/ml, respectively, obviously higher than (27.26±9.55) ng/ml and (2.41±0.94) ng/ml of benign pleural effusion (BPE) group (both P <0.01). Area under curve (AUC) of B7-H4 was 0.884 in MPE groupand the diagnostic sensitivity and specificity were 81.8% and 90.5%, respectively, at the optimized cut off value of 37.25 ng/ml. Likewise, area under curve (AUC) of CEA was 0.954 and the sensitivity and specificity were 87.3% and 95.2%, respectively, at the cut off value of 4.18 ng/ml. When B7-H4 >37.25 ng/ml or CEA>4.18 ng/ml, the sensitivity of diagnosis as MPE was down-regulated to 90.9% and the specificity was elevated to 88.1%. When B7-H4 >37.25 ng/ml and CEA>4.18 ng/ml, the sensitivity of diagnosis as MPE was down-regulated to 78.2% and the specificity was elevated to 97.6%. The sensitivity and specificity of combined detection of B7-H4 and CEA to diagnose MPE were elevated to 90.9% and 97.6%, respectively. The level of B7-H4 in MPE and BPE were both positively correlated with CEA ( r =0.670, P =0.001 in MPE and r =0.002, P =0.001 in BEP). Conclusions: B7-H4 is a potential tumor marker in diagnosing the benign and malignant pleural effusion. Although the diagnostic value of B7-H4 may not precede to CEA, the combined detection of B7-H4 and CEA can improve the diagnostic sensitivity and specificity of MPE.

  1. The use of hippocampal volumetric measurements to improve diagnostic accuracy in pediatric patients with mesial temporal sclerosis.

    PubMed

    Guzmán Pérez-Carrillo, Gloria J; Owen, Christopher; Schwetye, Katherine E; McFarlane, Spencer; Vellimana, Ananth K; Mar, Soe; Miller-Thomas, Michelle M; Shimony, Joshua S; Smyth, Matthew D; Benzinger, Tammie L S

    2017-06-01

    OBJECTIVE Many patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard. METHODS A cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis. RESULTS With the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%-86% and for PPV 64%-71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively). CONCLUSIONS Volumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.

  2. Prognostication of patients with clear cell renal cell carcinomas based on quantification of DNA methylation levels of CpG island methylator phenotype marker genes.

    PubMed

    Tian, Ying; Arai, Eri; Gotoh, Masahiro; Komiyama, Motokiyo; Fujimoto, Hiroyuki; Kanai, Yae

    2014-10-20

    The CpG island methylator phenotype (CIMP) of clear cell renal cell carcinomas (ccRCCs) is characterized by accumulation of DNA methylation at CpG islands and poorer patient outcome. The aim of this study was to establish criteria for prognostication of patients with ccRCCs using the ccRCC-specific CIMP marker genes. DNA methylation levels at 299 CpG sites in the 14 CIMP marker genes were evaluated quantitatively in tissue specimens of 88 CIMP-negative and 14 CIMP-positive ccRCCs in a learning cohort using the MassARRAY system. An additional 100 ccRCCs were also analyzed as a validation cohort. Receiver operating characteristic curve analysis showed that area under the curve values for the 23 CpG units including the 32 CpG sites in the 7 CIMP-marker genes, i.e. FAM150A, ZNF540, ZNF671, ZNF154, PRAC, TRH and SLC13A5, for discrimination of CIMP-positive from CIMP-negative ccRCCs were larger than 0.95. Criteria combining the 23 CpG units discriminated CIMP-positive from CIMP-negative ccRCCs with 100% sensitivity and specificity in the learning cohort. Cancer-free and overall survival rates of patients with CIMP-positive ccRCCs diagnosed using the criteria combining the 23 CpG units in a validation cohort were significantly lower than those of patients with CIMP-negative ccRCCs (P = 1.41 × 10-5 and 2.43 × 10-13, respectively). Patients with CIMP-positive ccRCCs in the validation cohort had a higher likelihood of disease-related death (hazard ratio, 75.8; 95% confidence interval, 7.81 to 735; P = 1.89 × 10-4) than those with CIMP-negative ccRCCs. The established criteria are able to reproducibly diagnose CIMP-positive ccRCCs and may be useful for personalized medicine for patients with ccRCCs.

  3. Bending the Curve: Sensitivity to Bending of Curved Paths and Application in Room-Scale VR.

    PubMed

    Langbehn, Eike; Lubos, Paul; Bruder, Gerd; Steinicke, Frank

    2017-04-01

    Redirected walking (RDW) promises to allow near-natural walking in an infinitely large virtual environment (VE) by subtle manipulations of the virtual camera. Previous experiments analyzed the human sensitivity to RDW manipulations by focusing on the worst-case scenario, in which users walk perfectly straight ahead in the VE, whereas they are redirected on a circular path in the real world. The results showed that a physical radius of at least 22 meters is required for undetectable RDW. However, users do not always walk exactly straight in a VE. So far, it has not been investigated how much a physical path can be bent in situations in which users walk a virtual curved path instead of a straight one. Such curved walking paths can be often observed, for example, when users walk on virtual trails, through bent corridors, or when circling around obstacles. In such situations the question is not, whether or not the physical path can be bent, but how much the bending of the physical path may vary from the bending of the virtual path. In this article, we analyze this question and present redirection by means of bending gains that describe the discrepancy between the bending of curved paths in the real and virtual environment. Furthermore, we report the psychophysical experiments in which we analyzed the human sensitivity to these gains. The results reveal encouragingly wider detection thresholds than for straightforward walking. Based on our findings, we discuss the potential of curved walking and present a first approach to leverage bent paths in a way that can provide undetectable RDW manipulations even in room-scale VR.

  4. Genetic and phenotypic relationships between immune defense, melanism and life-history traits at different temperatures and sexes in Tenebrio molitor.

    PubMed

    Prokkola, J; Roff, D; Kärkkäinen, T; Krams, I; Rantala, M J

    2013-08-01

    Insect cuticle melanism is linked to a number of life-history traits, and a positive relationship is hypothesized between melanism and the strength of immune defense. In this study, the phenotypic and genetic relationships between cuticular melanization, innate immune defense, individual development time and body size were studied in the mealworm beetle (Tenebrio molitor) using three different temperatures with a half-sib breeding design. Both innate immune defense and cuticle darkness were higher in females than males, and a positive correlation between the traits was found at the lowest temperature. The effect of temperature on all the measured traits was strong, with encapsulation ability and development time decreasing and cuticle darkness increasing with a rise in temperature, and body size showing a curved response. The analysis showed a highly integrated system sensitive to environmental change involving physiological, morphological and life-history traits.

  5. Genetic and phenotypic relationships between immune defense, melanism and life-history traits at different temperatures and sexes in Tenebrio molitor

    PubMed Central

    Prokkola, J; Roff, D; Kärkkäinen, T; Krams, I; Rantala, M J

    2013-01-01

    Insect cuticle melanism is linked to a number of life-history traits, and a positive relationship is hypothesized between melanism and the strength of immune defense. In this study, the phenotypic and genetic relationships between cuticular melanization, innate immune defense, individual development time and body size were studied in the mealworm beetle (Tenebrio molitor) using three different temperatures with a half-sib breeding design. Both innate immune defense and cuticle darkness were higher in females than males, and a positive correlation between the traits was found at the lowest temperature. The effect of temperature on all the measured traits was strong, with encapsulation ability and development time decreasing and cuticle darkness increasing with a rise in temperature, and body size showing a curved response. The analysis showed a highly integrated system sensitive to environmental change involving physiological, morphological and life-history traits. PMID:23572120

  6. Dynamic tuning of chemiresistor sensitivity using mechanical strain

    DOEpatents

    Martin, James E; Read, Douglas H

    2014-09-30

    The sensitivity of a chemiresistor sensor can be dynamically tuned using mechanical strain. The increase in sensitivity is a smooth, continuous function of the applied strain, and the effect can be reversible. Sensitivity tuning enables the response curve of the sensor to be dynamically optimized for sensing analytes, such as volatile organic compounds, over a wide concentration range.

  7. Drinking sucrose enhances quinpirole-induced yawning in rats

    PubMed Central

    Baladi, Michelle G; Newman, Amy H; Thomas, Yvonne M; France, Charles P

    2011-01-01

    Food and drugs can activate brain dopamine systems and sensitivity to the effects of drugs acting on those systems is influenced by amount and content of food consumed. This study examined the effects of drinking sucrose on behavioral effects of the directly-acting dopamine receptor agonist quinpirole. Male Sprague-Dawley rats (n=6/group) had free access to water or 10% sucrose and quinpirole dose-response curves (yawning and hypothermia) were generated weekly for 8 weeks. Subsequently, all rats drank water for 8 weeks with quinpirole dose-response curves determined on weeks 9, 10, and 16. In rats drinking sucrose, the ascending (D3 receptor-mediated), but not descending (D2 receptor-mediated), limb of the yawning dose-response curve shifted leftward. The D3 receptor-selective antagonist PG01037 shifted the ascending limb of the dose-response curve to the right in all rats. When rats that previously drank sucrose drank water, their sensitivity to quinpirole did not return to normal. Quinpirole-induced hypothermia was not different between groups. These data show that drinking sucrose increases sensitivity to a dopamine D3, but not D2, receptor-mediated effect and that this change is long lasting. Dopamine receptors mediate the effects of many drugs and the actions of those drugs are likely impacted by dietary factors. PMID:21979833

  8. Drinking sucrose enhances quinpirole-induced yawning in rats.

    PubMed

    Baladi, Michelle G; Newman, Amy H; Thomas, Yvonne M; France, Charles P

    2011-12-01

    Food and drugs can activate brain dopamine systems and sensitivity to the effects of drugs acting on those systems is influenced by amount and content of food consumed. This study examined the effects of drinking sucrose on behavioral effects of the direct-acting dopamine receptor agonist quinpirole. Male Sprague-Dawley rats (n=6/group) had free access to water or 10% sucrose and quinpirole dose-response curves (yawning and hypothermia) were generated weekly for 8 weeks. Subsequently, all rats drank water for 8 weeks with quinpirole dose-response curves determined on weeks 9, 10, and 16. In rats drinking sucrose, the ascending (D3 receptor-mediated), but not descending (D2 receptor-mediated), limb of the yawning dose-response curve shifted leftward. The D3 receptor-selective antagonist PG01037 shifted the ascending limb of the dose-response curve to the right in all rats. When rats that previously drank sucrose drank water, their sensitivity to quinpirole did not return to normal. Quinpirole-induced hypothermia was not different between groups. These data show that drinking sucrose increases sensitivity to a dopamine D3, but not D2, receptor-mediated effect and that this change is long lasting. Dopamine receptors mediate the effects of many drugs and the actions of those drugs are likely impacted by dietary factors.

  9. Receiver Operating Characteristic Curve Analysis of Beach Water Quality Indicator Variables

    PubMed Central

    Morrison, Ann Michelle; Coughlin, Kelly; Shine, James P.; Coull, Brent A.; Rex, Andrea C.

    2003-01-01

    Receiver operating characteristic (ROC) curve analysis is a simple and effective means to compare the accuracies of indicator variables of bacterial beach water quality. The indicator variables examined in this study were previous day's Enterococcus density and antecedent rainfall at 24, 48, and 96 h. Daily Enterococcus densities and 15-min rainfall values were collected during a 5-year (1996 to 2000) study of four Boston Harbor beaches. The indicator variables were assessed for their ability to correctly classify water as suitable or unsuitable for swimming at a maximum threshold Enterococcus density of 104 CFU/100 ml. Sensitivity and specificity values were determined for each unique previous day's Enterococcus density and antecedent rainfall volume and used to construct ROC curves. The area under the ROC curve was used to compare the accuracies of the indicator variables. Twenty-four-hour antecedent rainfall classified elevated Enterococcus densities more accurately than previous day's Enterococcus density (P = 0.079). An empirically derived threshold for 48-h antecedent rainfall, corresponding to a sensitivity of 0.75, was determined from the 1996 to 2000 data and evaluated to ascertain if the threshold would produce a 0.75 sensitivity with independent water quality data collected in 2001 from the same beaches. PMID:14602593

  10. Adiponectin/(FBG × FIns) as a predictor of insulin sensitivity and metabolic syndrome in patients with polycystic ovary syndrome.

    PubMed

    Xu, Xiaohui; Lai, Yerui; Yang, Gangyi; Yang, Mengliu; Li, Ling; Zhang, Qin; Liu, Hua; Zheng, Hongting; Zhu, Danping

    2016-12-01

    The euglycemic-hyperinsulinemic clamp is not available in most clinical settings. An accessible and inexpensive measurement for identifying insulin resistance (IR) is necessary. Our aim is to assess whether the adiponectin (ADI) index (ADI/[FBG × FIns]) is a better surrogate index for the assessment of IR or metabolic syndrome (MetS).A population-based cross-sectional study was conducted including 100 healthy women and 99 polycystic ovary syndrome patients. The euglycemic-hyperinsulinemic clamp was performed. Circulating ADI levels were determined by ELISA.Polycystic ovary syndrome and polycystic ovary syndrome plus MetS subjects had higher products of fasting triglycerides and glucose (TyG), Homeostasis Model Assessment of Insulin Resistance (HOMA-IR), increased ratios of the area under the curve for insulin/the area under the curve for glucose (AUCi/AUCg), but lower ADI index as compared with healthy subjects. Partial correlation analysis in all populations showed that the M-value was significantly negatively correlated with HOMA-IR, TyG, TG/HDL, and AUCi/AUCg, and correlated positively with the ADI index. The r value of Pearson correlation between the ADI index and M-value was greater than that of the correlation between HOMA-IR, TyG, TG/HDL-C, and AUCi/AUCg. The optimal cut-off value of the ADI index for detection of IR was 0.67, with a sensitivity of 89.4% and a specificity of 88.1%, whereas for detection of MetS, it was 0.32, with a sensitivity of 88.7% and a specificity of 71.0%.The ADI index may be a surrogate marker in detecting IR and MetS.

  11. An electrochemical immunoassay for the screening of celiac disease in saliva samples.

    PubMed

    Adornetto, Gianluca; Fabiani, Laura; Volpe, Giulia; De Stefano, Alessia; Martini, Sonia; Nenna, Raffaella; Lucantoni, Federica; Bonamico, Margherita; Tiberti, Claudio; Moscone, Danila

    2015-09-01

    A highly sensitive electrochemical immunoassay for the initial diagnosis of celiac disease (CD) in saliva samples that overcomes the problems related to its high viscosity and to the low concentration of anti-transglutaminase antigen (tTG) IgA in this medium has been developed for the first time. The system uses magnetic beads (MBs) covered with tTG, which reacts with the anti-tTG IgA antibodies present in positive saliva samples. An anti-human IgA, conjugated with alkaline phosphate (AP) enzyme, was used as the label and a strip of eight magnetized screen-printed electrodes as the electrochemical transducer. In particular, two different immunoassay approaches were optimized and blindly compared to analyze a large number of saliva samples, whose anti-tTG IgA levels were independently determined by the radioimmunoassay (RIA) method. The obtained results, expressed as Ab index, were used to perform a diagnostic test evaluation through the construction of receiver operating characteristic (ROC) curves. The approach, involving a pre-incubation between the anti-human IgA-AP and saliva samples prior to the addition of MBs-tTG, showed a cutoff of 0.022 with 95% clinical sensitivity and 96% clinical specificity. The area under the ROC curve is equal to 1, a result that classifies our test as "perfect." This study demonstrates that it is possible to perform the screening of CD with a rapid, simple, inexpensive, and sensitive method able to detect anti-tTG antibodies in saliva samples, which are easily obtained by non-invasive techniques. This aspect is of fundamental importance to screen a large number of subjects, especially in the pediatric age.

  12. PIVKA-II is a useful tool for diagnostic characterization of ultrasound-detected liver nodules in cirrhotic patients

    PubMed Central

    Saitta, Carlo; Raffa, Giuseppina; Alibrandi, Angela; Brancatelli, Santa; Lombardo, Daniele; Tripodi, Gianluca; Raimondo, Giovanni; Pollicino, Teresa

    2017-01-01

    Abstract Protein induced by vitamin K absence-II (PIVKA-II) is a potential screening marker for hepatocellular carcinoma (HCC). Limited data are available about its utility in discriminating neoplastic from regenerative nodules at ultrasonography (US) evaluation in cirrhotic patients. Aim of this study was to investigate the diagnostic utility of PIVKA-II in cases showing liver nodules of uncertain diagnosis at US. Ninety cirrhotics with US evidence of liver nodule(s) were enrolled. All patients underwent blood sampling within 1 week of US and were thereafter followed up. HCC was confirmed in 40/90 cases, and in all cases it was in a very early/early stage. All sera were tested for PIVKA-II and alpha-fetoprotein (AFP) at the end of follow-up. PIVKA-II at a cut off of 60 mAU/mL was significantly associated with HCC at both univariate and multivariate analysis (P = .016 and P = .032, respectively). AFP at a cut off of 6.5 ng/mL was not associated with HCC at univariate analysis (P = .246). ROC curves showed that PIVKA-II had 60% sensitivity, 88% specificity, 80% positive predictive value (PPV), and 73% negative predictive value (NPV), whereas AFP had 67% sensitivity, 68% specificity, 63% PPV, and 72% NPV. AUROC curves showed that the combination of both biomarkers increased the diagnostic accuracy for HCC (AUC 0.76; sensitivity 70%, specificity 94%, PPV 91%, and NPV 79%). In conclusion, PIVKA-II is a useful tool for the diagnostic definition of US-detected liver nodules in cirrhotic patients, and it provides high diagnostic accuracy for HCC when combined with AFP. PMID:28658121

  13. Procalcitonin for the early diagnosis of sepsis in burn patients: A retrospective study.

    PubMed

    Cabral, Luís; Afreixo, Vera; Santos, Filipe; Almeida, Luís; Paiva, José Artur

    2017-11-01

    The gold standard for sepsis diagnosis in burn patient still relies on microbiological cultures, which take 48-72h to provide results, delaying the start of antimicrobial therapy. Thus, biomarkers allowing an earlier sepsis diagnosis in burn patients are needed. This retrospective observational study included 150 burn patients with total burned surface area ≥15%. Clinical diagnosis of sepsis among these patients was done according to the American Burn Association criteria. Biomarker (procalcitonin, white blood cells and platelet countings, prothrombinemia, D-dimers, C-reactive protein, blood lactate and temperature) values were available for 48 patients without sepsis (2767 timepoints) and 102 patients with sepsis (652 timepoints). Quantitative variables were compared with Mann-Whitney tests and qualitative variables were compared with Pearson chi-square test. Effect size was measured by the probability of superiority. Receiver operating characteristic (ROC) curves evaluate capacity for sepsis diagnosis. Sensitivity, specificity, positive and negative predictive values were calculated for some cut-off values, including the best cut-off defined by the maximum of Youden index. Statistically significant differences between the groups of septic and non-septic patients, with medium to large effect size, were detected for all the biomarkers considered, except temperature. PCT was the biomarker with the largest AUC and effect size (AUC=0.71). Analysis of the PCT ROC curve showed that 0.5ng/mL cut-off presented highest sensitivity and lowest specificity, whereas 1.5ng/mL cut-off was associated with lowest sensitivity and highest specificity. Procalcitonin showed to be the best of the biomarkers studied for an early diagnosis of sepsis. Its use should be considered in antimicrobial stewardship programs in Burn Units. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  14. Potential diagnostic value of serum p53 antibody for detecting colorectal cancer: A meta-analysis.

    PubMed

    Meng, Rongqin; Wang, Yang; He, Liang; He, Yuanqing; Du, Zedong

    2018-04-01

    Numerous studies have assessed the diagnostic value of serum p53 (s-p53) antibody in patients with colorectal cancer (CRC); however, results remain controversial. The present study aimed to comprehensively and quantitatively summarize the potential diagnostic value of s-p53 antibody in CRC. The present study utilized databases, including PubMed and EmBase, systematically regarding s-p53 antibody diagnosis in CRC, accessed on and prior to 31 July 2016. The quality of all the included studies was assessed using quality assessment of studies of diagnostic accuracy (QUADAS). The result of pooled sensitivity, pooled specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were analyzed and compared with overall accuracy measures using diagnostic odds ratios (DORs) and area under the curve (AUC) analysis. Publication bias and heterogeneity were also assessed. A total of 11 trials that enrolled a combined 3,392 participants were included in the meta-analysis. Approximately 72.73% (8/11) of the included studies were of high quality (QUADAS score >7), and all were retrospective case-control studies. The pooled sensitivity was 0.19 [95% confidence interval (CI), 0.18-0.21] and pooled specificity was 0.93 (95% CI, 0.92-0.94). Results also demonstrated a PLR of 4.56 (95% CI, 3.27-6.34), NLR of 0.78 (95% CI, 0.71-0.85) and DOR of 6.70 (95% CI, 4.59-9.76). The symmetrical summary receiver operating characteristic curve was 0.73. Furthermore, no evidence of publication bias or heterogeneity was observed in the meta-analysis. Meta-analysis data indicated that s-p53 antibody possesses potential diagnostic value for CRC. However, discrimination power was somewhat limited due to the low sensitivity.

  15. Adiponectin/(FBG × FIns) as a predictor of insulin sensitivity and metabolic syndrome in patients with polycystic ovary syndrome

    PubMed Central

    Xu, Xiaohui; Lai, Yerui; Yang, Gangyi; Yang, Mengliu; Li, Ling; Zhang, Qin; Liu, Hua; Zheng, Hongting; Zhu, Danping

    2016-01-01

    Abstract The euglycemic–hyperinsulinemic clamp is not available in most clinical settings. An accessible and inexpensive measurement for identifying insulin resistance (IR) is necessary. Our aim is to assess whether the adiponectin (ADI) index (ADI/[FBG × FIns]) is a better surrogate index for the assessment of IR or metabolic syndrome (MetS). A population-based cross-sectional study was conducted including 100 healthy women and 99 polycystic ovary syndrome patients. The euglycemic–hyperinsulinemic clamp was performed. Circulating ADI levels were determined by ELISA. Polycystic ovary syndrome and polycystic ovary syndrome plus MetS subjects had higher products of fasting triglycerides and glucose (TyG), Homeostasis Model Assessment of Insulin Resistance (HOMA-IR), increased ratios of the area under the curve for insulin/the area under the curve for glucose (AUCi/AUCg), but lower ADI index as compared with healthy subjects. Partial correlation analysis in all populations showed that the M-value was significantly negatively correlated with HOMA-IR, TyG, TG/HDL, and AUCi/AUCg, and correlated positively with the ADI index. The r value of Pearson correlation between the ADI index and M-value was greater than that of the correlation between HOMA-IR, TyG, TG/HDL-C, and AUCi/AUCg. The optimal cut-off value of the ADI index for detection of IR was 0.67, with a sensitivity of 89.4% and a specificity of 88.1%, whereas for detection of MetS, it was 0.32, with a sensitivity of 88.7% and a specificity of 71.0%. The ADI index may be a surrogate marker in detecting IR and MetS. PMID:27930544

  16. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients.

    PubMed

    Pham, Thuy Anh Vu

    2017-11-01

    The aims of this case control study were to correlate the serum and salivary urea as well as creatinine levels; and to evaluate salivary urea and creatinine as noninvasive alternatives to serum for creatinine estimation in chronic kidney disease (CKD) patients. Blood and saliva samples were collected from 112 CKD patients and 108 subjects without CKD for quantitative analysis of urea and creatinine. Spearman's correlation coefficients between salivary and serum urea as well as creatinine were obtained. Receiver operating characteristic analysis was done to assess the diagnostic tests of salivary urea and creatinine. Cut-off values were determined based on the best trade-off between the sensitivity and specificity for both salivary urea and creatinine. Salivary urea and creatinine concentrations were significantly higher in CKD patients than those in control subjects; and increased by the stages of the severity of the disease. The positive correlation was significantly found between salivary and serum creatinine (r  =  0.90) and between salivary and serum urea (r  =  0.73). Area under the curve for salivary urea was 0.76 and a cut-off value of 14.25 mmol/L gave a sensitivity of 82.9% and specificity of 57.8%. Area under the curve for salivary creatinine was 0.92 and a cut-off value of 0.24 mg/dL gave a sensitivity of 86.5% and specificity of 87.2%. Both salivary urea and creatinine have a high capacity for serum creatinine estimation. Salivary urea and creatinine tests can be used as low-cost, easily accessible and noninvasive tools for screening, diagnosing, monitoring treatment outcomes and ascertaining prognosis of chronic kidney disease.

  17. Countergradient variation in locomotor performance of two sympatric Polynesian skinks (Emoia impar, Emoia cyanura).

    PubMed

    McElroy, Matthew T

    2014-01-01

    Physiological function in ectotherms is tightly linked to body temperature. As a result, the thermal sensitivity of physiological function may evolve to optimize fitness across different thermal environments. One hypothesis for the evolution of thermal sensitivity, coadaptation, predicts that optimal temperatures for performance should evolve to match the temperatures that an organism experiences in nature. Another hypothesis, countergradient variation, posits that genetic variation can compensate for decreased performance in cool environments, leading to physiological phenotypes that do not track environmental temperatures. On Mo'orea, French Polynesia, thermal ecology and physiology were studied in two morphologically similar skinks that differ in habitat use. Previous studies show that Emoia impar tends to inhabit closed-canopy and interior habitats that are cooler compared to those inhabited by Emoia cyanura, but these differences had not been quantified on Mo'orea. The goal of this study was to determine whether this pattern of habitat partitioning exists on Mo'orea and relates to interspecific differences in thermal physiology and to evaluate whether the evolution of thermal sensitivity supports coadaptation or countergradient variation. I found that E. impar inhabits closed-canopy habitats with cooler substrates and with higher altitudes compared to habitats of E. cyanura. Although the two species do not differ significantly in critical thermal minimum, E. impar has a significantly lower preferred body temperature and critical thermal maximum than does E. cyanura. Despite a preference for cooler habitats and temperatures, E. impar has a warmer optimal temperature for sprint speed and sprints faster than E. cyanura at all temperatures, which supports the countergradient model of thermal adaptation. These results are robust to three different curve-fitting functions and support the view that generalist/specialist trade-offs do not universally constrain the evolution of performance curves.

  18. Value of lower respiratory tract surveillance cultures to predict bacterial pathogens in ventilator-associated pneumonia: systematic review and diagnostic test accuracy meta-analysis.

    PubMed

    Brusselaers, Nele; Labeau, Sonia; Vogelaers, Dirk; Blot, Stijn

    2013-03-01

    In ventilator-associated pneumonia (VAP), early appropriate antimicrobial therapy may be hampered by involvement of multidrug-resistant (MDR) pathogens. A systematic review and diagnostic test accuracy meta-analysis were performed to analyse whether lower respiratory tract surveillance cultures accurately predict the causative pathogens of subsequent VAP in adult patients. Selection and assessment of eligibility were performed by three investigators by mutual consideration. Of the 525 studies retrieved, 14 were eligible for inclusion (all in English; published since 1994), accounting for 791 VAP episodes. The following data were collected: study and population characteristics; in- and exclusion criteria; diagnostic criteria for VAP; microbiological workup of surveillance and diagnostic VAP cultures. Sub-analyses were conducted for VAP caused by Staphylococcus aureus, Pseudomonas spp., and Acinetobacter spp., MDR microorganisms, frequency of sampling, and consideration of all versus the most recent surveillance cultures. The meta-analysis showed a high accuracy of surveillance cultures, with pooled sensitivities up to 0.75 and specificities up to 0.92 in culture-positive VAP. The area under the curve (AUC) of the hierarchical summary receiver-operating characteristic curve demonstrates moderate accuracy (AUC: 0.90) in predicting multidrug resistance. A sampling frequency of >2/week (sensitivity 0.79; specificity 0.96) and consideration of only the most recent surveillance culture (sensitivity 0.78; specificity 0.96) are associated with a higher accuracy of prediction. This study provides evidence for the benefit of surveillance cultures in predicting MDR bacterial pathogens in VAP. However, clinical and statistical heterogeneity, limited samples sizes, and bias remain important limitations of this meta-analysis.

  19. Predicting suicide attempts with the SAD PERSONS scale: a longitudinal analysis.

    PubMed

    Bolton, James M; Spiwak, Rae; Sareen, Jitender

    2012-06-01

    The SAD PERSONS scale is a widely used risk assessment tool for suicidal behavior despite a paucity of supporting data. The objective of this study was to examine the ability of the scale in predicting suicide attempts. Participants consisted of consecutive referrals (N=4,019) over 2 years (January 1, 2009 to December 31, 2010) to psychiatric services in the emergency departments of the 2 largest tertiary care hospitals in the province of Manitoba, Canada. SAD PERSONS and Modified SAD PERSONS (MSPS) scale scores were recorded for individuals at their index and all subsequent presentations. The 2 main outcome measures in the study included current suicide attempts (at index presentation) and future suicide attempts (within the next 6 months). The ability of the scales to predict suicide attempts was evaluated with logistic regression, sensitivity and specificity analyses, and receiver operating characteristic curves. 566 people presented with suicide attempts (14.1% of the sample). Both SAD PERSONS and MSPS showed poor predictive ability for future suicide attempts. Compared to low risk scores, high risk baseline scores had low sensitivity (19.6% and 40.0%, respectively) and low positive predictive value (5.3% and 7.4%, respectively). SAD PERSONS did not predict suicide attempts better than chance (area under the curve =0.572; 95% confidence interval [CI], 0.51-0.64; P value nonsignificant). Stepwise regression identified 5 original scale items that accounted for the greatest proportion of future suicide attempt variance. High risk scores using this model had high sensitivity (93.5%) and were associated with a 5-fold higher likelihood of future suicide attempt presentation (odds ratio =5.58; 95% CI, 2.24-13.86; P<.001). In their current form, SAD PERSONS and MSPS do not accurately predict future suicide attempts. © Copyright 2012 Physicians Postgraduate Press, Inc.

  20. Using Machine-Learned Bayesian Belief Networks to Predict Perioperative Risk of Clostridium Difficile Infection Following Colon Surgery

    PubMed Central

    Bilchik, Anton; Eberhardt, John; Kalina, Philip; Nissan, Aviram; Johnson, Eric; Avital, Itzhak; Stojadinovic, Alexander

    2012-01-01

    Background Clostridium difficile (C-Diff) infection following colorectal resection is an increasing source of morbidity and mortality. Objective We sought to determine if machine-learned Bayesian belief networks (ml-BBNs) could preoperatively provide clinicians with postoperative estimates of C-Diff risk. Methods We performed a retrospective modeling of the Nationwide Inpatient Sample (NIS) national registry dataset with independent set validation. The NIS registries for 2005 and 2006 were used for initial model training, and the data from 2007 were used for testing and validation. International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) codes were used to identify subjects undergoing colon resection and postoperative C-Diff development. The ml-BBNs were trained using a stepwise process. Receiver operating characteristic (ROC) curve analysis was conducted and area under the curve (AUC), positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results From over 24 million admissions, 170,363 undergoing colon resection met the inclusion criteria. Overall, 1.7% developed postoperative C-Diff. Using the ml-BBN to estimate C-Diff risk, model AUC is 0.75. Using only known a priori features, AUC is 0.74. The model has two configurations: a high sensitivity and a high specificity configuration. Sensitivity, specificity, PPV, and NPV are 81.0%, 50.1%, 2.6%, and 99.4% for high sensitivity and 55.4%, 81.3%, 3.5%, and 99.1% for high specificity. C-Diff has 4 first-degree associates that influence the probability of C-Diff development: weight loss, tumor metastases, inflammation/infections, and disease severity. Conclusions Machine-learned BBNs can produce robust estimates of postoperative C-Diff infection, allowing clinicians to identify high-risk patients and potentially implement measures to reduce its incidence or morbidity. PMID:23611947

  1. Design and Validation of a Prehospital Scale to Predict Stroke Severity: The Cincinnati Prehospital Stroke Severity Scale

    PubMed Central

    Katz, Brian S.; McMullan, Jason T.; Sucharew, Heidi; Adeoye, Opeolu; Broderick, Joseph P.

    2015-01-01

    Background and Purpose We derived and validated the Cincinnati Prehospital Stroke Severity Scale (CPSSS) to identify patients with severe strokes and large vessel occlusion (LVO). Methods CPSSS was developed with regression tree analysis, objectivity, anticipated ease in administration by EMS personnel, and the presence of cortical signs. We derived and validated the tool using the two NINDS t-PA Stroke Study trials and IMS III Trial cohorts, respectively, to predict severe stroke [NIH stroke scale (NIHSS) ≥15] and LVO. Standard test characteristics were determined and receiver operator curves were generated and summarized by the area under the curve (AUC). Results CPSSS score ranges from 0-4; composed and scored by individual NIHSS items: 2 points for presence of conjugate gaze (NIHSS ≥1); 1 point for presence of arm weakness (NIHSS ≥2); and 1 point for presence abnormal level of consciousness (LOC) commands and questions (NIHSS LOC ≥1 each). In the derivation set, CPSSS had an AUC of 0.89; score ≥2 was 89% sensitive and 73% specific in identifying NIHSS ≥15. Validation results were similar with an AUC of 0.83; score ≥2 was 92% sensitive, 51% specific, a positive likelihood ratio (PLR) of 3.3 and a negative likelihood ratio (NLR) of 0.15 in predicting severe stroke. For 222/303 IMS III subjects with LVO, CPSSS had an AUC of 0.67; a score ≥2 was 83% sensitive, 40% specific, PLR of 1.4, and NLR of 0.4 in predicting LVO. Conclusions CPSSS can identify stroke patients with NIHSS ≥15 and LVO. Prospective prehospital validation is warranted. PMID:25899242

  2. Drinking sucrose or saccharin enhances sensitivity of rats to quinpirole-induced yawning

    PubMed Central

    Serafine, Katherine M; Bentley, Todd A; Kilborn, Dylan J; Koek, Wouter; France, Charles P

    2015-01-01

    Diet can impact sensitivity of rats to some of the behavioral effects of drugs acting on dopamine systems. The current study tested whether continuous access to sucrose is necessary to increase yawning induced by the dopamine receptor agonist quinpirole, or if intermittent access is sufficient. These studies also tested whether sensitivity to quinpirole-induced yawning increases in rats drinking the non-caloric sweetener saccharin. Dose-response curves (0.0032–0.32 mg/kg) for quinpirole-induced yawning were determined once weekly in rats with free access to standard chow and either continuous access to water, 10% sucrose solution, or 0.1% saccharin solution, or intermittent access to sucrose or saccharin (i.e., 2 days per week with access to water on other days). Cumulative doses of quinpirole increased then decreased yawning, resulting in an inverted U-shaped dose-response curve. Continuous or intermittent access to sucrose enhanced sensitivity to quinpirole-induced yawning. Continuous, but not intermittent, access to saccharin also enhanced sensitivity to quinpirole-induced yawning. In all groups, pretreatment with the selective D3 receptor antagonist PG 01037 shifted the ascending limb of the quinpirole dose-response curve to the right, while pretreatment with the selective D2 receptor antagonist L-741626 shifted the descending limb to the right. These results suggest that even intermittent consumption of diets containing highly palatable substances (e.g. sucrose) alters sensitivity to drugs acting on dopamine systems in a manner that could be important in vulnerability to abuse drugs. PMID:26189020

  3. Recovery curves of the surface electric field after lightning discharges occurring between the positive charge pocket and negative charge centre in a thundercloud

    NASA Astrophysics Data System (ADS)

    Pawar, S. D.; Kamra, A. K.

    2002-12-01

    Surface observations of the electric field recovery curves of the lightning discharges occurring between the positive charge pocket and negative main charge centre in an overhead thundercloud are reported. Such recovery curves are observed to have an additional step of very slow field-change observed at an after-discharge value of electric field equal to 5-6 kV m-1. The behavior of recovery curves is explained in terms of the coronae charge and the relative efficiencies of the charge generating processes responsible for growth of positive charge pocket and main negative charge centre in the thundercloud. The charging currents responsible for the growth of charge in positive charge pockets is computed to be 2-4 times larger than that for the growth of the main negative charge. However, the charge destroyed in such a discharge is found to be comparable to that in a discharge between the main charge centres of the thundercloud.

  4. A novel method for routine quality assurance of volumetric-modulated arc therapy.

    PubMed

    Wang, Qingxin; Dai, Jianrong; Zhang, Ke

    2013-10-01

    Volumetric-modulated arc therapy (VMAT) is delivered through synchronized variation of gantry angle, dose rate, and multileaf collimator (MLC) leaf positions. The delivery dynamic nature challenges the parameter setting accuracy of linac control system. The purpose of this study was to develop a novel method for routine quality assurance (QA) of VMAT linacs. ArcCheck is a detector array with diodes distributing in spiral pattern on cylindrical surface. Utilizing its features, a QA plan was designed to strictly test all varying parameters during VMAT delivery on an Elekta Synergy linac. In this plan, there are 24 control points. The gantry rotates clockwise from 181° to 179°. The dose rate, gantry speed, and MLC positions cover their ranges commonly used in clinic. The two borders of MLC-shaped field seat over two columns of diodes of ArcCheck when the gantry rotates to the angle specified by each control point. The ratio of dose rate between each of these diodes and the diode closest to the field center is a certain value and sensitive to the MLC positioning error of the leaf crossing the diode. Consequently, the positioning error can be determined by the ratio with the help of a relationship curve. The time when the gantry reaches the angle specified by each control point can be acquired from the virtual inclinometer that is a feature of ArcCheck. The gantry speed between two consecutive control points is then calculated. The aforementioned dose rate is calculated from an acm file that is generated during ArcCheck measurements. This file stores the data measured by each detector in 50 ms updates with each update in a separate row. A computer program was written in MATLAB language to process the data. The program output included MLC positioning errors and the dose rate at each control point as well as the gantry speed between control points. To evaluate this method, this plan was delivered for four consecutive weeks. The actual dose rate and gantry speed were compared with the QA plan specified. Additionally, leaf positioning errors were intentionally introduced to investigate the sensitivity of this method. The relationship curves were established for detecting MLC positioning errors during VMAT delivery. For four consecutive weeks measured, 98.4%, 94.9%, 89.2%, and 91.0% of the leaf positioning errors were within ± 0.5 mm, respectively. For the intentionally introduced leaf positioning systematic errors of -0.5 and +1 mm, the detected leaf positioning errors of 20 Y1 leaf were -0.48 ± 0.14 and 1.02 ± 0.26 mm, respectively. The actual gantry speed and dose rate closely followed the values specified in the VMAT QA plan. This method can assess the accuracy of MLC positions and the dose rate at each control point as well as the gantry speed between control points at the same time. It is efficient and suitable for routine quality assurance of VMAT.

  5. Implications of Nonlinear Concentration Response Curve for Ozone related Mortality on Health Burden Assessment

    EPA Science Inventory

    We characterize the sensitivity of the ozone attributable health burden assessment with respect to different modeling strategies of concentration-response function. For this purpose, we develop a flexible Bayesian hierarchical model allowing for a nonlinear ozone risk curve with ...

  6. Signal Attenuation Curve for Different Surface Detector Arrays

    NASA Astrophysics Data System (ADS)

    Vicha, J.; Travnicek, P.; Nosek, D.; Ebr, J.

    2014-06-01

    Modern cosmic ray experiments consisting of large array of particle detectors measure the signals of electromagnetic or muon components or their combination. The correction for an amount of atmosphere passed is applied to the surface detector signal before its conversion to the shower energy. Either Monte Carlo based approach assuming certain composition of primaries or indirect estimation using real data and assuming isotropy of arrival directions can be used. Toy surface arrays of different sensitivities to electromagnetic and muon components are assumed in MC simulations to study effects imposed on attenuation curves for varying composition or possible high energy anisotropy. The possible sensitivity of the attenuation curve to the mass composition is also tested for different array types focusing on a future apparatus that can separate muon and electromagnetic component signals.

  7. WE-E-18A-04: Precision In-Vivo Dosimetry Using Optically Stimulated Luminescence Dosimeters and a Pulsed-Stimulating Dose Reader

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Q; Herrick, A; Hoke, S

    Purpose: A new readout technology based on pulsed optically stimulating luminescence is introduced (microSTARii, Landauer, Inc, Glenwood, IL60425). This investigation searches for approaches that maximizes the dosimetry accuracy in clinical applications. Methods: The sensitivity of each optically stimulated luminescence dosimeter (OSLD) was initially characterized by exposing it to a given radiation beam. After readout, the luminescence signal stored in the OSLD was erased by exposing its sensing area to a 21W white LED light for 24 hours. A set of OSLDs with consistent sensitivities was selected to calibrate the dose reader. Higher order nonlinear curves were also derived from themore » calibration readings. OSLDs with cumulative doses below 15 Gy were reused. Before an in-vivo dosimetry, the OSLD luminescence signal was erased with the white LED light. Results: For a set of 68 manufacturer-screened OSLDs, the measured sensitivities vary in a range of 17.3%. A sub-set of the OSLDs with sensitivities within ±1% was selected for the reader calibration. Three OSLDs in a group were exposed to a given radiation. Nine groups were exposed to radiation doses ranging from 0 to 13 Gy. Additional verifications demonstrated that the reader uncertainty is about 3%. With an external calibration function derived by fitting the OSLD readings to a 3rd-order polynomial, the dosimetry uncertainty dropped to 0.5%. The dose-luminescence response curves of individual OSLDs were characterized. All curves converge within 1% after the sensitivity correction. With all uncertainties considered, the systematic uncertainty is about 2%. Additional tests emulating in-vivo dosimetry by exposing the OSLDs under different radiation sources confirmed the claim. Conclusion: The sensitivity of individual OSLD should be characterized initially. A 3rd-order polynomial function is a more accurate representation of the dose-luminescence response curve. The dosimetry uncertainty specified by the manufacturer is 4%. Following the proposed approach, it can be controlled to 2%.« less

  8. The unique observing capabilities of the Swift x-ray telescope

    NASA Astrophysics Data System (ADS)

    Hill, J. E.; Angelini, L.; Morris, D. C.; Burrows, D. N.; Abbey, A. F.; Campana, S.; Capalbi, M.; Cusumano, G.; Kennea, J. A.; Klar, R.; Mangels, C.; Moretti, A.; Osborne, J. P.; Perri, M.; Racusin, J.; Tagliaferri, G.; Tamburelli, F.; Wood, P.; Nousek, J. A.; Wells, A.

    2005-08-01

    The XRT is a sensitive, autonomous X-ray imaging spectrometer onboard the Swift Gamma-Ray Burst Observatory. The unique observing capabilities of the XRT allow it to autonomously refine the Swift BAT positions (~1-4' uncertainty) to better than 2.5 arcsec in XRT detector coordinates, within 5 seconds of target acquisition by the Swift Observatory for typical bursts, and to measure the flux, spectrum, and light curve of GRBs and afterglows over a wide dynamic range covering more than seven orders of magnitude in flux (62 Crab to < 1 mCrab). The results of the rapid positioning capability of the XRT are presented here for both known sources and newly discovered GRBs, demonstrating the ability to automatically utilise one of two integration times according to the burst brightness, and to correct the position for alignment offsets caused by the fast pointing performance and variable thermal environment of the satellite as measured by the Telescope Alignment Monitor. The onboard results are compared to the positions obtained by groundbased follow-up. After obtaining the position, the XRT switches between four CCD readout modes, automatically optimising the scientific return from the source depending on the flux of the GRB. Typical data products are presented here.

  9. The unique observing capabilities of the Swift x-ray telescope

    NASA Astrophysics Data System (ADS)

    Hill, J. E.; Angelini, L.; Morris, D. C.; Burrows, D. N.; Abbey, A. F.; Campana, S.; Cusumano, G.; Kennea, J. A.; Klar, R.; Mangels, C.; Moretti, A.; Perri, M.; Racusin, J.; Tagliaferri, G.; Tamburelli, F.; Wood, P.; Nousek, J. A.; Wells, A.

    2005-01-01

    The XRT is a sensitive, autonomous X-ray imaging spectrometer onboard the Swift Gamma-Ray Burst Observatory. The unique observing capabilities of the XRT allow it to autonomously refine the Swift BAT positions (~1-4' uncertainty) to better than 2.5 arcsec in XRT detector coordinates, within 5 seconds of target acquisition by the Swift Observatory for typical bursts, and to measure the flux, spectrum, and light curve of GRBs and afterglows over a wide dynamic range covering more than seven orders of magnitude in flux (62 Crab to < 1 mCrab). The results of the rapid positioning capability of the XRT are presented here for both known sources and newly discovered GRBs, demonstrating the ability to automatically utilise one of two integration times according to the burst brightness, and to correct the position for alignment offsets caused by the fast pointing performance and variable thermal environment of the satellite as measured by the Telescope Alignment Monitor. The onboard results are compared to the positions obtained by groundbased follow-up. After obtaining the position, the XRT switches between four CCD readout modes, automatically optimising the scientific return from the source depending on the flux of the GRB. Typical data products are presented here.

  10. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis.

    PubMed

    Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R

    2017-09-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.

  11. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials.

    PubMed

    Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan

    2016-05-01

    Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.

  12. The learning curve for narrow-band imaging in the diagnosis of precancerous gastric lesions by using Web-based video.

    PubMed

    Dias-Silva, Diogo; Pimentel-Nunes, Pedro; Magalhães, Joana; Magalhães, Ricardo; Veloso, Nuno; Ferreira, Carlos; Figueiredo, Pedro; Moutinho, Pedro; Dinis-Ribeiro, Mário

    2014-06-01

    A simplified narrow-band imaging (NBI) endoscopy classification of gastric precancerous and cancerous lesions was derived and validated in a multicenter study. This classification comes with the need for dissemination through adequate training. To address the learning curve of this classification by endoscopists with differing expertise and to assess the feasibility of a YouTube-based learning program to disseminate it. Prospective study. Five centers. Six gastroenterologists (3 trainees, 3 fully trained endoscopists [FTs]). Twenty tests provided through a Web-based program containing 10 randomly ordered NBI videos of gastric mucosa were taken. Feedback was sent 7 days after every test submission. Measures of accuracy of the NBI classification throughout the time. From the first to the last 50 videos, a learning curve was observed with a 10% increase in global accuracy, for both trainees (from 64% to 74%) and FTs (from 56% to 65%). After 200 videos, sensitivity and specificity of 80% and higher for intestinal metaplasia were observed in half the participants, and a specificity for dysplasia greater than 95%, along with a relevant likelihood ratio for a positive result of 7 to 28 and likelihood ratio for a negative result of 0.21 to 0.82, were achieved by all of the participants. No constant learning curve was observed for the identification of Helicobacter pylori gastritis and sensitivity to dysplasia. The trainees had better results in all of the parameters, except specificity for dysplasia, compared with the FTs. Globally, participants agreed that the program's structure was adequate, except on the feedback, which should have consisted of a more detailed explanation of each answer. No formal sample size estimate. A Web-based learning program could be used to teach and disseminate classifications in the endoscopy field. In this study, an NBI classification for gastric mucosal features seems to be easily learned for the identification of gastric preneoplastic lesions. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. Computer-aided diagnosis of prostate cancer using a deep convolutional neural network from multiparametric MRI.

    PubMed

    Song, Yang; Zhang, Yu-Dong; Yan, Xu; Liu, Hui; Zhou, Minxiong; Hu, Bingwen; Yang, Guang

    2018-04-16

    Deep learning is the most promising methodology for automatic computer-aided diagnosis of prostate cancer (PCa) with multiparametric MRI (mp-MRI). To develop an automatic approach based on deep convolutional neural network (DCNN) to classify PCa and noncancerous tissues (NC) with mp-MRI. Retrospective. In all, 195 patients with localized PCa were collected from a PROSTATEx database. In total, 159/17/19 patients with 444/48/55 observations (215/23/23 PCas and 229/25/32 NCs) were randomly selected for training/validation/testing, respectively. T 2 -weighted, diffusion-weighted, and apparent diffusion coefficient images. A radiologist manually labeled the regions of interest of PCas and NCs and estimated the Prostate Imaging Reporting and Data System (PI-RADS) scores for each region. Inspired by VGG-Net, we designed a patch-based DCNN model to distinguish between PCa and NCs based on a combination of mp-MRI data. Additionally, an enhanced prediction method was used to improve the prediction accuracy. The performance of DCNN prediction was tested using a receiver operating characteristic (ROC) curve, and the area under the ROC curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Moreover, the predicted result was compared with the PI-RADS score to evaluate its clinical value using decision curve analysis. Two-sided Wilcoxon signed-rank test with statistical significance set at 0.05. The DCNN produced excellent diagnostic performance in distinguishing between PCa and NC for testing datasets with an AUC of 0.944 (95% confidence interval: 0.876-0.994), sensitivity of 87.0%, specificity of 90.6%, PPV of 87.0%, and NPV of 90.6%. The decision curve analysis revealed that the joint model of PI-RADS and DCNN provided additional net benefits compared with the DCNN model and the PI-RADS scheme. The proposed DCNN-based model with enhanced prediction yielded high performance in statistical analysis, suggesting that DCNN could be used in computer-aided diagnosis (CAD) for PCa classification. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Bioimpedance spectroscopy can precisely discriminate human breast carcinoma from benign tumors.

    PubMed

    Du, Zhenggui; Wan, Hangyu; Chen, Yu; Pu, Yang; Wang, Xiaodong

    2017-01-01

    Intraoperative frozen pathology is critical when a breast tumor is not diagnosed before surgery. However, frozen tumor tissues always present various microscopic morphologies, leading to a high misdiagnose rate from frozen section examination. Thus, we aimed to identify breast tumors using bioimpedance spectroscopy (BIS), a technology that measures the tissues' impedance. We collected and measured 976 specimens from breast patients during surgery, including 581 breast cancers, 190 benign tumors, and 205 normal mammary gland tissues. After measurement, Cole-Cole curves were generated by a bioimpedance analyzer and parameters R0/R∞, fc, and α were calculated from the curve. The Cole-Cole curves showed a trend to differentiate mammary gland, benign tumors, and cancer. However, there were some curves overlapped with other groups, showing that it is not an ideal model. Subsequent univariate analysis of R0/R∞, fc, and α showed significant differences between benign tumor and cancer. However, receiver operating characteristic (ROC) analysis indicated the diagnostic value of fc and R0/R∞ were not superior to frozen sections (area under curve [AUC] = 0.836 and 0.849, respectively), and α was useless in diagnosis (AUC = 0.596). After further research, we found a scatter diagram that showed a synergistic effect of the R0/R∞ and fc, in discriminating cancer from benign tumors. Thus, we used multivariate analysis, which revealed that these two parameters were independent predictors, to combine them. A simplified equation, RF = 0.2fc + 3.6R0/R∞, based on multivariate analysis was developed. The ROC curve for RF' showed an AUC = 0.939, and the sensitivity and specificity were 82.62% and 95.79%, respectively. To match a clinical setting, the diagnostic criteria were set at 6.91 and 12.9 for negative and positive diagnosis, respectively. In conclusion, RF' derived from BIS can discriminate benign tumor and cancers, and integrated criteria were developed for diagnosis.

  15. Bioimpedance spectroscopy can precisely discriminate human breast carcinoma from benign tumors

    PubMed Central

    Du, Zhenggui; Wan, Hangyu; Chen, Yu; Pu, Yang; Wang, Xiaodong

    2017-01-01

    Abstract Intraoperative frozen pathology is critical when a breast tumor is not diagnosed before surgery. However, frozen tumor tissues always present various microscopic morphologies, leading to a high misdiagnose rate from frozen section examination. Thus, we aimed to identify breast tumors using bioimpedance spectroscopy (BIS), a technology that measures the tissues’ impedance. We collected and measured 976 specimens from breast patients during surgery, including 581 breast cancers, 190 benign tumors, and 205 normal mammary gland tissues. After measurement, Cole-Cole curves were generated by a bioimpedance analyzer and parameters R0/R∞, fc, and α were calculated from the curve. The Cole-Cole curves showed a trend to differentiate mammary gland, benign tumors, and cancer. However, there were some curves overlapped with other groups, showing that it is not an ideal model. Subsequent univariate analysis of R0/R∞, fc, and α showed significant differences between benign tumor and cancer. However, receiver operating characteristic (ROC) analysis indicated the diagnostic value of fc and R0/R∞ were not superior to frozen sections (area under curve [AUC] = 0.836 and 0.849, respectively), and α was useless in diagnosis (AUC = 0.596). After further research, we found a scatter diagram that showed a synergistic effect of the R0/R∞ and fc, in discriminating cancer from benign tumors. Thus, we used multivariate analysis, which revealed that these two parameters were independent predictors, to combine them. A simplified equation, RF′ = 0.2fc + 3.6R0/R∞, based on multivariate analysis was developed. The ROC curve for RF′ showed an AUC = 0.939, and the sensitivity and specificity were 82.62% and 95.79%, respectively. To match a clinical setting, the diagnostic criteria were set at 6.91 and 12.9 for negative and positive diagnosis, respectively. In conclusion, RF′ derived from BIS can discriminate benign tumor and cancers, and integrated criteria were developed for diagnosis. PMID:28121948

  16. On the mean profiles of radio pulsars - II. Reconstruction of complex pulsar light curves and other new propagation effects

    NASA Astrophysics Data System (ADS)

    Hakobyan, H. L.; Beskin, V. S.; Philippov, A. A.

    2017-08-01

    Our previous paper outlined the general aspects of the theory of radio light curve and polarization formation for pulsars. We predicted the one-to-one correspondence between the tilt of the linear polarization position angle of the the circular polarization. However, some of the radio pulsars indicate a clear deviation from that correlation. In this paper, we apply the theory of the radio wave propagation in the pulsar magnetosphere for the analysis of individual effects leading to these deviations. We show that within our theory the circular polarization of a given mode can switch its sign, without the need to introduce a new radiation mode or other effects. Moreover, we show that the generation of different emission modes on different altitudes can explain pulsars, that presumably have the X-O-X light-curve pattern, different from what we predict. General properties of radio emission within our propagation theory are also discussed. In particular, we calculate the intensity patterns for different radiation altitudes and present light curves for different observer viewing angles. In this context we also study the light curves and polarization profiles for pulsars with interpulses. Further, we explain the characteristic width of the position angle curves by introducing the concept of a wide emitting region. Another important feature of radio polarization profiles is the shift of the position angle from the centre, which in some cases demonstrates a weak dependence on the observation frequency. Here we demonstrate that propagation effects do not necessarily imply a significant frequency-dependent change of the position angle curve.

  17. Are driving and overtaking on right curves more dangerous than on left curves?

    PubMed

    Othman, Sarbaz; Thomson, Robert; Lannér, Gunnar

    2010-01-01

    It is well known that crashes on horizontal curves are a cause for concern in all countries due to the frequency and severity of crashes at curves compared to road tangents. A recent study of crashes in western Sweden reported a higher rate of crashes in right curves than left curves. To further understand this result, this paper reports the results of novel analyses of the responses of vehicles and drivers during negotiating and overtaking maneuvers on curves for right hand traffic. The overall objectives of the study were to find road parameters for curves that affect vehicle dynamic responses, to analyze these responses during overtaking maneuvers on curves, and to link the results with driver behavior for different curve directions. The studied road features were speed, super-elevation, radius and friction including their interactions, while the analyzed vehicle dynamic factors were lateral acceleration and yaw angular velocity. A simulation program, PC-Crash, has been used to simulate road parameters and vehicle response interaction in curves. Overtaking maneuvers have been simulated for all road feature combinations in a total of 108 runs. Analysis of variances (ANOVA) was performed, using two sided randomized block design, to find differences in vehicle responses for the curve parameters. To study driver response, a field test using an instrumented vehicle and 32 participants was reviewed as it contained longitudinal speed and acceleration data for analysis. The simulation results showed that road features affect overtaking performance in right and left curves differently. Overtaking on right curves was sensitive to radius and the interaction of radius with road condition; while overtaking on left curves was more sensitive to super-elevation. Comparisons of lateral acceleration and yaw angular velocity during these maneuvers showed different vehicle response configurations depending on curve direction and maneuver path. The field test experiments also showed that drivers behave differently depending on the curve direction where both speed and acceleration were higher on right than left curves. The implication of this study is that curve direction should be taken into consideration to a greater extent when designing and redesigning curves. It appears that the driver and the vehicle are influenced by different infrastructure factors depending on the curve direction. In addition, the results suggest that the vehicle dynamics response alone cannot explain the higher crash risk in right curves. Further studies of the links between driver, vehicle, and highway characteristics are needed, such as naturalistic driving studies, to identify the key safety indicators for highway safety.

  18. Prognostic factors of Bell's palsy: prospective patient collected observational study.

    PubMed

    Fujiwara, Takashi; Hato, Naohito; Gyo, Kiyofumi; Yanagihara, Naoaki

    2014-07-01

    The purpose of this study was to evaluate various parameters potentially influencing poor prognosis in Bell's palsy and to assess the predictive value for Bell's palsy. A single-center prospective patient collected observation and validation study was conducted. To evaluate the correlation between patient characteristics and poor prognosis, we performed univariate and multivariate analyzes of age, gender, side of palsy, diabetes mellitus, hypertension, and facial grading score 1 week after onset. To evaluate the accuracy of the facial grading score, we prepared a receiver operating characteristic (ROC) curve and calculated the area under the ROC curve (AUROC). We also calculated sensitivity, specificity, positive/negative likelihood ratio, and positive/negative predictive value. We included Bell's palsy patients who attended Ehime University Hospital within 1 week after onset between 1977 and 2011. We excluded patients who were less than 15 years old and lost-to-follow-up within 6 months. The main outcome was defined as non-recovery at 6 months after onset. In total, 679 adults with Bell's palsy were included. The facial grading score at 1 week showed a correlation with non-recovery in the multivariate analysis, although age, gender, side of palsy, diabetes mellitus, and hypertension did not. The AUROC of the facial grading score was 0.793. The Y-system score at 1 week moderate accurately predicted non-recovery at 6 months in Bell's palsy.

  19. Two classes of ouabain binding sites in ferret heart and two forms of Na+-K+-ATPase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Y.C.; Akera, T.

    1987-05-01

    In partially purified Na+-K+-adenosinetriphosphatase (ATPase) obtained from ferret heart, ouabain produced a monophasic inhibition curve; however, the curve spanned over 5 logarithmic units, indicating the presence of more than one classes of enzyme. (/sup 3/H)ouabain binding studies revealed high-and low-affinity binding sites in approximately equal abundance, with apparent dissociation constants of 10 and 230 nM, respectively. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of phosphoenzyme formed from (gamma-/sup 32/P)ATP showed two distinct K+-sensitive bands of approximately 100,000 molecular weight. Phosphoenzyme formation from the high-molecular-weight alpha(+) form was selectively inhibited by N-ethylmaleimide. Ouabain caused a 50% inhibition of phosphorylation of the alpha(+) formmore » at 40 nM and the lower-molecular-weight alpha form at 300 nM. In papillary muscle preparations, 1-30 nM ouabain produced a modest positive inotropic effect that reached an apparent plateau at 30 nM. Further increases in ouabain concentrations, however, produced additional and prominent inotropic effects at 0.1-10 microM. These results indicate for the first time in cardiac muscle that the high- and low-affinity ouabain binding sites are associated with the alpha(+) and alpha forms of the Na+-K+-ATPase, respectively, and that binding of ouabain to either of these sites causes enzyme inhibition and the positive inotropic effect.« less

  20. Antimicrobial effects of lysophosphatidylcholine on methicillin-resistant Staphylococcus aureus.

    PubMed

    Miyazaki, Haruko; Midorikawa, Naoko; Fujimoto, Saki; Miyoshi, Natsumi; Yoshida, Hideto; Matsumoto, Tetsuya

    2017-07-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important health care-associated and community-associated pathogen and causes a large number of infections worldwide. For the purpose of application to topical treatment of MRSA infection, we examined the antimicrobial effects of lysophosphatidylcholine (LPC) on MRSA strains. We also investigated the combination effect of LPC and gentamicin on MRSA growth. The LPC minimum inhibitory concentrations (MIC) for Gram-positive ( S. aureus, Staphylococcus epidermidis , and Streptococcus pneumoniae ) and Gram-negative ( Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae , and Pseudomonas aeruginosa ) bacteria were measured by the broth microdilution method. The mechanism of LPC-mediated MRSA killing was investigated by membrane permeability analysis with DiSC3(5) fluorescence and growth curve analysis. Lastly, the effects of LPC on gentamicin-induced bactericidal activity were determined in combination treatment studies with 15 gentamicin-resistant MRSA isolates from the skin, nose, or ears. The LPC MIC for Gram-positive bacteria varied between 32 µg/ml and >2048 µg/ml, whereas that for all Gram-negative bacteria was >2048 µg/ml. Consistently, membrane permeability analysis showed that LPC was substantially more effective in inducing membrane permeability in Gram-positive bacteria than in Gram-negative counterparts. Growth curve analysis in cotreatment studies demonstrated that LPC has intrinsic bactericidal effects and can also potentiate gentamicin sensitivity in resistant MRSA strains. Our study demonstrates that LPC exhibits intrinsic antimicrobial effects and can enhance the antimicrobial effects of gentamicin for resistant MRSA strains, suggesting that LPC may be a beneficial additive in topical antibiotics for superficial skin infections.

  1. Antimicrobial effects of lysophosphatidylcholine on methicillin-resistant Staphylococcus aureus

    PubMed Central

    Miyazaki, Haruko; Midorikawa, Naoko; Fujimoto, Saki; Miyoshi, Natsumi; Yoshida, Hideto; Matsumoto, Tetsuya

    2017-01-01

    Objectives: Methicillin-resistant Staphylococcus aureus (MRSA) is an important health care-associated and community-associated pathogen and causes a large number of infections worldwide. For the purpose of application to topical treatment of MRSA infection, we examined the antimicrobial effects of lysophosphatidylcholine (LPC) on MRSA strains. We also investigated the combination effect of LPC and gentamicin on MRSA growth. Methods: The LPC minimum inhibitory concentrations (MIC) for Gram-positive (S. aureus, Staphylococcus epidermidis, and Streptococcus pneumoniae) and Gram-negative (Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae, and Pseudomonas aeruginosa) bacteria were measured by the broth microdilution method. The mechanism of LPC-mediated MRSA killing was investigated by membrane permeability analysis with DiSC3(5) fluorescence and growth curve analysis. Lastly, the effects of LPC on gentamicin-induced bactericidal activity were determined in combination treatment studies with 15 gentamicin-resistant MRSA isolates from the skin, nose, or ears. Results: The LPC MIC for Gram-positive bacteria varied between 32 µg/ml and >2048 µg/ml, whereas that for all Gram-negative bacteria was >2048 µg/ml. Consistently, membrane permeability analysis showed that LPC was substantially more effective in inducing membrane permeability in Gram-positive bacteria than in Gram-negative counterparts. Growth curve analysis in cotreatment studies demonstrated that LPC has intrinsic bactericidal effects and can also potentiate gentamicin sensitivity in resistant MRSA strains. Conclusions: Our study demonstrates that LPC exhibits intrinsic antimicrobial effects and can enhance the antimicrobial effects of gentamicin for resistant MRSA strains, suggesting that LPC may be a beneficial additive in topical antibiotics for superficial skin infections. PMID:28748087

  2. Validity of Alcohol Use Disorder Identification Test-Korean Revised Version for Screening Alcohol Use Disorder according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition Criteria.

    PubMed

    Chang, Jung Wei; Kim, Jong Sung; Jung, Jin Gyu; Kim, Sung Soo; Yoon, Seok Joon; Jang, Hak Sun

    2016-11-01

    The Alcohol Use Disorder Identification Test (AUDIT) has been widely used to identify alcohol use disorder (AUD). This study evaluated the validity of the AUDIT-Korean revised version (AUDIT-KR) for screening AUD according to Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) criteria. This research was conducted with 443 subjects who visited the Chungnam National University Hospital for a comprehensive medical examination. All subjects completed the demographic questionnaire and AUDIT-KR without assistance. Subjects were divided into two groups according to DSM-5 criteria: an AUD group, which included patients that fit the criteria for AUD (120 males and 21 females), and a non-AUD group, which included 146 males and 156 females that did not meet AUD criteria. The appropriate cut-off values, sensitivity, specificity, and positive and negative predictive values of the AUDIT-KR were evaluated. The mean±standard deviation AUDIT-KR scores were 10.32±7.48 points in males and 3.23±4.42 points in females. The area under the receiver operating characteristic curve (95% confidence interval, CI) of the AUDIT-KR for identifying AUD was 0.884 (0.840-0.920) in males and 0.962 (0.923-0.985) in females. The optimal cut-off value of the AUDIT-KR was 10 points for males (sensitivity, 81.90%; specificity, 81.33%; positive predictive value, 77.2%; negative predictive value, 85.3%) and 5 points for females (sensitivity, 100.00%; specificity, 88.54%; positive predictive value, 52.6%; negative predictive value, 100.0%). The AUDIT-KR has high reliability and validity for identifying AUD according to DSM-5 criteria.

  3. Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals.

    PubMed

    Romem, Ayal; Romem, Anat; Koldobskiy, Dafna; Scharf, Steven M

    2014-03-15

    Increasing awareness of the high prevalence of obstructive sleep apnea (OSA) and its impact on health in conjunction with high cost, inconvenience, and short supply of in-lab polysomnography (PSG) has led to the development of more convenient, affordable, and accessible diagnostic devices. We evaluated the reliability and accuracy of a single-channel (finger pulse-oximetry) photoplethysmography (PPG)-based device for detection of OSA (Morpheus Ox). Among a cohort of 73 patients referred for in-laboratory evaluation of OSA, 65 were simultaneously monitored with the PPG based device while undergoing PSG. Among these, 19 had significant cardiopulmonary comorbidities. Using the PSG as the "gold standard," the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), as well as the positive likelihood ratio (+LR) for an apnea hypopnea index (AHI)PSG > 5/h and AHIPSG > 15/h were calculated for the PPG. Valid results were available for 65 subjects. Mean age: 52.1 ± 14.2, Male: 52%, and BMI: 36.3 ± 9.7 kg/m(2). Positive correlation was found between PPG-derived and PSG-derived AHI (r = 0.81, p < 0.001). For AHIPSG > 5/h, sensitivity was 80%, specificity 86%, PPV 93%, NPV 68%, and +LR was 5.9. For AHIPSG > 15/h, sensitivity was 70%, specificity 91%, PPV 80%, NPV 85%, and +LR was 7.83. The corresponding areas under the receiver operator curves were 0.91 and 0.9. PPG-derived data compare well with simultaneous in-lab PSG in the diagnosis of suspected OSA among patients with and without cardiopulmonary comorbidities. Romem A; Romem A; Koldobskiy D; Scharf SM. Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals.

  4. Asymmetry dependence of the caloric curve for mononuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoel, C.; Sobotka, L. G.; Charity, R. J.

    2007-01-15

    The asymmetry dependence of the caloric curve, for mononuclear configurations, is studied as a function of neutron-to-proton asymmetry with a model that allows for independent variation of the neutron and proton surface diffusenesses. The evolution of the effective mass with density and excitation is included in a schematic fashion and the entropies are extracted in a local density approximation. The plateau in the caloric curve displays only a slight sensitivity to the asymmetry.

  5. Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.

    PubMed

    Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E

    2018-02-20

    Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2  > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.

  6. Usefulness of Chest Radiographs for Scoliosis Screening: A Comparison with Thoraco-Lumbar Standing Radiographs

    PubMed Central

    Oh, Chang Hyun; Kim, Chan Gyu; Lee, Myoung Seok; Park, Hyeong-Chun; Park, Chong Oon

    2012-01-01

    Purpose The purposes of this study were to evaluate the usefulness and limitations of chest radiographs in scoliosis screening and to compare these results with those of thoraco-lumbar standing radiographs (TLSR). Materials and Methods During Korean conscription, 419 males were retrospectively examined using both chest radiographs and TLSR to confirm the scoliosis and Cobb angle at the Regional Military Manpower. We compared the types of spinal curves and Cobb angles as measured from different radiographs. Results In the pattern of spinal curves, the overall matching rate of chest radiographs using TLSR was about 58.2% (244 of 419 cases). Cobb angle differences between chest radiographs and TLSR with meaningful difference was observed in 156 cases (37.2%); a relatively high proportion (9.5%) of Cobb angle differences more than 10 degrees was also observed. The matching rate of both spinal curve types and Cobb angle accuracy between chest radiographs and TLSR was 27.9% (117 among 419 cases). Chest radiographs for scoliosis screening were observed with 93.94% of sensitivity and 61.67% of specificity in thoracic curves; however, less than 40% of sensitivity (38.27%, 20.00%, and 25.80%) and more than 95% of specificity (97.34%, 99.69%, and 98.45%) were observed in thoraco-lumbar, lumbar, and double major curves, respectively. Conclusion The accuracy of chest radiographs for scoliosis screening was low. The incidence of thoracic curve scoliosis was overestimated and lumbar curve scoliosis was easily missed by chest radiography. Scoliosis screening using chest radiography has limited values, nevertheless, it is useful method for detecting thoracic curve scoliosis. PMID:23074120

  7. Neck injury criteria formulation and injury risk curves for the ejection environment: a pilot study.

    PubMed

    Parr, Jeffrey C; Miller, Michael E; Pellettiere, Joseph A; Erich, Roger A

    2013-12-01

    Helmet mounted displays provide increased pilot capability, but can also increase the risk of injury during ejection. The National Highway Transportation Safety Administration's (NHTSA's) neck injury criteria (Nij) metric is evaluated for understanding the impact of helmet mass on the risk of injury and modified risk curves are developed which are compatible with the needs of the aviation community. Existent human subject data collected under various accelerative and head loading conditions were applied to understand the sensitivity of the Nij construct to changes in acceleration and helmet mass, as well as its stability with respect to gender, body mass, neck circumference, and sitting height. A portion of this data was combined with data from an earlier postmortem human subject study to create pilot study modified risk curves. These curves were compared and contrasted with the NHTSA risk curves. A statistically significant difference in the peak mean Nij was observed when seat acceleration increased by 2 G, but not when helmet mass was varied from 1.6 kg to 2 kg at a constant seat acceleration of 8 G. Although NHTSA risk curves predict a 13% risk of AIS 2+ injury for the 8-G, 2-kg helmet condition mean Nij of 0.138, no AIS 2+ injuries were observed. Modified risk curves were produced which predict a 0.91% risk of AIS 2+ injury under these conditions. The Nij was shown to be sensitive to changes in acceleration and generally robust to anthropometric differences between individuals. Modified risk curves are proposed which improve risk prediction at lower Nij values.

  8. IMRT QA: Selecting gamma criteria based on error detection sensitivity.

    PubMed

    Steers, Jennifer M; Fraass, Benedick A

    2016-04-01

    The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.

  9. Effects of Prone Position and Positive End-Expiratory Pressure on Noninvasive Estimators of ICP: A Pilot Study.

    PubMed

    Robba, Chiara; Bragazzi, Nicola Luigi; Bertuccio, Alessandro; Cardim, Danilo; Donnelly, Joseph; Sekhon, Mypinder; Lavinio, Andrea; Duane, Derek; Burnstein, Rowan; Matta, Basil; Bacigaluppi, Susanna; Lattuada, Marco; Czosnyka, Marek

    2017-07-01

    Prone positioning and positive end-expiratory pressure can improve pulmonary gas exchange and respiratory mechanics. However, they may be associated with the development of intracranial hypertension. Intracranial pressure (ICP) can be noninvasively estimated from the sonographic measurement of the optic nerve sheath diameter (ONSD) and from the transcranial Doppler analysis of the pulsatility (ICPPI) and the diastolic component (ICPFVd) of the velocity waveform. The effect of the prone positioning and positive end-expiratory pressure on ONSD, ICPFVd, and ICPPI was assessed in a prospective study of 30 patients undergoing spine surgery. One-way repeated measures analysis of variance, fixed-effect multivariate regression models, and receiver operating characteristic analyses were used to analyze numerical data. The mean values of ONSD, ICPFVd, and ICPPI significantly increased after change from supine to prone position. Receiver operating characteristic analyses demonstrated that, among the noninvasive methods, the mean ONSD measure had the greatest area under the curve signifying it is the most effective in distinguishing a hypothetical change in ICP between supine and prone positioning (0.86±0.034 [0.79 to 0.92]). A cutoff of 0.43 cm was found to be a best separator of ONSD value between supine and prone with a specificity of 75.0 and a sensitivity of 86.7. Noninvasive ICP estimation may be useful in patients at risk of developing intracranial hypertension who require prone positioning.

  10. A novel quantitative reverse-transcription PCR (qRT-PCR) for the enumeration of total bacteria, using meat micro-flora as a model.

    PubMed

    Dolan, Anthony; Burgess, Catherine M; Barry, Thomas B; Fanning, Seamus; Duffy, Geraldine

    2009-04-01

    A sensitive quantitative reverse-transcription PCR (qRT-PCR) method was developed for enumeration of total bacteria. Using two sets of primers separately to target the ribonuclease-P (RNase P) RNA transcripts of gram positive and gram negative bacteria. Standard curves were generated using SYBR Green I kits for the LightCycler 2.0 instrument (Roche Diagnostics) to allow quantification of mixed microflora in liquid media. RNA standards were used and extracted from known cell equivalents and subsequently converted to cDNA for the construction of standard curves. The number of mixed bacteria in culture was determined by qRT-PCR, and the results correlated (r(2)=0.88, rsd=0.466) with the total viable count over the range from approx. Log(10) 3 to approx. Log(10) 7 CFU ml(-1). The rapid nature of this assay (8 h) and its potential as an alternative method to the standard plate count method to predict total viable counts and shelf life are discussed.

  11. Using violet laser-induced chlorophyll fluorescence emission spectra for crop yield assessment of cowpea (Vigna unguiculata (L) Walp) varieties

    NASA Astrophysics Data System (ADS)

    Anderson, Benjamin; Buah-Bassuah, Paul K.; Tetteh, Jonathan P.

    2004-07-01

    The use of violet laser-induced chlorophyll fluorescence (LICF) emission spectra to monitor the growth of five varieties of cowpea in the University of Cape Coast Botanical Garden is presented. Radiation from a continuous-wave violet laser diode emitting at 396 nm through a fibre is closely incident on in vivo leaves of cowpea to excite chlorophyll fluorescence, which is detected by an integrated spectrometer with CCD readout. The chlorophyll fluorescence spectra with peaks at 683 and 731 nm were used for growth monitoring of the cowpea plants over three weeks and analysed using Gaussian spectral functions with curve fitted parameters to determine the peak positions, area under the spectral curve and the intensity ratio F683/F731. The variation in the intensity ratio of the chlorophyll bands showed sensitive changes indicating the photosynthetic activity of the cowpea varieties. A discussion of the fluorescence result as compared to conventional assessment is presented with regard to discrimination between the cowpea varieties in terms of crop yield performance.

  12. A Study of the Potential to Detect Caries Lesions at the White-Spot Stage Using V(Z) Technique

    NASA Astrophysics Data System (ADS)

    Bakulin, E. Y.; Denisova, L. A.; Maev, R. Gr.

    Current wide-spread methods of non-destructive methods of caries diagnostics, such as X-ray techniques, do not provide the possibility to efficiently detect enamel caries lesions at the beginning ("white-spot") stage, when the tooth tissue is only slightly altered and no loss of the tissue occurs. Therefore, it is of paramount importance to develop new, more sensitive methods of caries diagnostics. In this paper, certain aspects of the ultrasonic approach to the problem are discussed - in particular, detection of the enamel's surface caries at the white-spot stage with a focused ultrasonic sensor positioned in front of the caries lesion (without cross-sectioning the tooth). Theoretical model using V(z) approach for layered media was applied to perform computer simulations resulting in V(z) curves for the different parameters of carious tissue and the degree of degradation. The curves were analyzed and it was shown that, comparing to a short-pulse/echo technique, V(z) approach provides much better distinction between sound and carious enamel and even makes possible to evaluate the degree of demineralization.

  13. Can a Resident's Publication Record Predict Fellowship Publications?

    PubMed Central

    Prasad, Vinay; Rho, Jason; Selvaraj, Senthil; Cheung, Mike; Vandross, Andrae; Ho, Nancy

    2014-01-01

    Background Internal medicine fellowship programs have an incentive to select fellows who will ultimately publish. Whether an applicant's publication record predicts long term publishing remains unknown. Methods Using records of fellowship bound internal medicine residents, we analyzed whether publications at time of fellowship application predict publications more than 3 years (2 years into fellowship) and up to 7 years after fellowship match. We calculate the sensitivity, specificity, positive and negative predictive values and likelihood ratios for every cutoff number of application publications, and plot a receiver operator characteristic curve of this test. Results Of 307 fellowship bound residents, 126 (41%) published at least one article 3 to 7 years after matching, and 181 (59%) of residents do not publish in this time period. The area under the receiver operator characteristic curve is 0.59. No cutoff value for application publications possessed adequate test characteristics. Conclusion The number of publications an applicant has at time of fellowship application is a poor predictor of who publishes in the long term. These findings do not validate the practice of using application publications as a tool for selecting fellows. PMID:24658088

  14. Electron percolation in realistic models of carbon nanotube networks

    NASA Astrophysics Data System (ADS)

    Simoneau, Louis-Philippe; Villeneuve, Jérémie; Rochefort, Alain

    2015-09-01

    The influence of penetrable and curved carbon nanotubes (CNT) on the charge percolation in three-dimensional disordered CNT networks have been studied with Monte-Carlo simulations. By considering carbon nanotubes as solid objects but where the overlap between their electron cloud can be controlled, we observed that the structural characteristics of networks containing lower aspect ratio CNT are highly sensitive to the degree of penetration between crossed nanotubes. Following our efficient strategy to displace CNT to different positions to create more realistic statistical models, we conclude that the connectivity between objects increases with the hard-core/soft-shell radii ratio. In contrast, the presence of curved CNT in the random networks leads to an increasing percolation threshold and to a decreasing electrical conductivity at saturation. The waviness of CNT decreases the effective distance between the nanotube extremities, hence reducing their connectivity and degrading their electrical properties. We present the results of our simulation in terms of thickness of the CNT network from which simple structural parameters such as the volume fraction or the carbon nanotube density can be accurately evaluated with our more realistic models.

  15. Can a resident's publication record predict fellowship publications?

    PubMed

    Prasad, Vinay; Rho, Jason; Selvaraj, Senthil; Cheung, Mike; Vandross, Andrae; Ho, Nancy

    2014-01-01

    Internal medicine fellowship programs have an incentive to select fellows who will ultimately publish. Whether an applicant's publication record predicts long term publishing remains unknown. Using records of fellowship bound internal medicine residents, we analyzed whether publications at time of fellowship application predict publications more than 3 years (2 years into fellowship) and up to 7 years after fellowship match. We calculate the sensitivity, specificity, positive and negative predictive values and likelihood ratios for every cutoff number of application publications, and plot a receiver operator characteristic curve of this test. Of 307 fellowship bound residents, 126 (41%) published at least one article 3 to 7 years after matching, and 181 (59%) of residents do not publish in this time period. The area under the receiver operator characteristic curve is 0.59. No cutoff value for application publications possessed adequate test characteristics. The number of publications an applicant has at time of fellowship application is a poor predictor of who publishes in the long term. These findings do not validate the practice of using application publications as a tool for selecting fellows.

  16. Numerical Simulation of Particle Motion in a Curved Channel

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Nie, Deming

    2018-01-01

    In this work the lattice Boltzmann method (LBM) is used to numerically study the motion of a circular particle in a curved channel at intermediate Reynolds numbers (Re). The effects of the Reynolds number and the initial particle position are taken into account. Numerical results include the streamlines, particle trajectories and final equilibrium positions. It has been found that the particle is likely to migrate to a similar equilibrium position irrespective of its initial position when Re is large.

  17. Checking the predictive accuracy of basic symptoms against ultra high-risk criteria and testing of a multivariable prediction model: Evidence from a prospective three-year observational study of persons at clinical high-risk for psychosis.

    PubMed

    Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A

    2017-09-01

    The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, P<.05), whereas BS did not predict psychosis beyond mere chance (AUC=0.52, P=.730). Sensitivity and specificity were 0.83 and 0.47 for UHR, and 0.96 and 0.09 for BS. UHR plus BS achieved an AUC=0.66, with sensitivity and specificity of 0.75 and 0.56. In comparison, baseline antipsychotic medication yielded a predictive accuracy of AUC=0.62 (sensitivity=0.42; specificity=0.82). A multivariable prediction model comprising continuous measures of positive symptoms and verbal IQ achieved a substantially improved prognostic accuracy (AUC=0.85; sensitivity=0.86; specificity=0.85; positive predictive value=0.54; negative predictive value=0.97). We showed that BS have no predictive accuracy beyond chance, while UHR criteria poorly predict conversion to psychosis. Combining BS with UHR criteria did not improve the predictive accuracy of UHR alone. In contrast, dimensional measures of both positive symptoms and verbal IQ showed excellent prognostic validity. A critical re-thinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Tumor necrosis factor α level in cerebrospinal fluid for bacterial and aseptic meningitis: a diagnostic meta-analysis.

    PubMed

    Lv, S; Zhao, J; Zhang, J; Kwon, S; Han, M; Bian, R; Fu, H; Zhang, Y; Pan, H

    2014-08-01

    In our previous study, tumor necrosis factor α (TNF-α) was identified as an effective target for sepsis patients (Int J Clin Pract, 68, 2014, 520). TNF-α in cerebrospinal fluid (CSF) was also investigated for its utility in the differential diagnosis of bacterial and aseptic meningitis. However, there has been neither definite nor convincing evidence so far. Here the overall diagnostic accuracy of TNF-α in differentiation between bacterial and aseptic meningitis was evaluated through the meta-analysis of diagnostic tests. The sensitivity, specificity and other measures of accuracy were pooled using random effect models. Summary receiver operating characteristic curves were used to assess overall test performance. Publication bias was evaluated using funnel plots, and sensitivity analysis was also introduced. A total of 21 studies involving bacterial meningitis (678) and aseptic meningitis (694) involved a total of 1372 patients. The pooled sensitivity and specificity for the TNF-α test were 0.83 [95% confidence interval (CI) 0.80-0.86, I(2)  = 65.1] and 0.92 (95% CI 0.89-0.94, I(2)  = 61.8), respectively. The positive likelihood ratio was 12.05 (95% CI 7.41-19.60, I(2)  = 36.5), the negative likelihood ratio was 0.17 (95% CI 0.13-0.24, I(2)  = 59.4), and TNF-α was significantly associated with bacterial meningitis, with a diagnostic odds ratio of 49.84 (95% CI 28.53-87.06, I(2)  = 47.9). The overall accuracy of the TNF-α test was very high with the area under the curve 0.9317. Publication bias was absent, and sensitivity analysis suggested that our results were highly stable. Our meta-analysis suggested that TNF-α could be recommended as a useful marker for diagnosis of bacterial meningitis and differential diagnosis between bacterial and aseptic meningitis with high sensitivity and specificity. Thus, hospitals should be encouraged to conduct TNF-α tests in CSF after lumbar puncture. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.

  19. 1SXPS: A Deep Swift X-Ray Telescope Point Source Catalog with Light Curves and Spectra

    NASA Technical Reports Server (NTRS)

    Evans, P. A.; Osborne, J. P.; Beardmore, A. P.; Page, K. L.; Willingale, R.; Mountford, C. J.; Pagani, C.; Burrows, D. N.; Kennea, J. A.; Perri, M.; hide

    2013-01-01

    We present the 1SXPS (Swift-XRT point source) catalog of 151,524 X-ray point sources detected by the Swift-XRT in 8 yr of operation. The catalog covers 1905 sq deg distributed approximately uniformly on the sky. We analyze the data in two ways. First we consider all observations individually, for which we have a typical sensitivity of approximately 3 × 10(exp -13) erg cm(exp -2) s(exp -1) (0.3-10 keV). Then we co-add all data covering the same location on the sky: these images have a typical sensitivity of approximately 9 × 10(exp -14) erg cm(exp -2) s(exp -1) (0.3-10 keV). Our sky coverage is nearly 2.5 times that of 3XMM-DR4, although the catalog is a factor of approximately 1.5 less sensitive. The median position error is 5.5 (90% confidence), including systematics. Our source detection method improves on that used in previous X-ray Telescope (XRT) catalogs and we report greater than 68,000 new X-ray sources. The goals and observing strategy of the Swift satellite allow us to probe source variability on multiple timescales, and we find approximately 30,000 variable objects in our catalog. For every source we give positions, fluxes, time series (in four energy bands and two hardness ratios), estimates of the spectral properties, spectra and spectral fits for the brightest sources, and variability probabilities in multiple energy bands and timescales.

  20. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    PubMed

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  1. Increasing the sensitivity of the Jaffe reaction for creatinine

    NASA Technical Reports Server (NTRS)

    Tom, H. Y.

    1973-01-01

    Study of analytical procedure has revealed that linearity of creatinine calibration curve can be extended by using 0.03 molar picric acid solution made up in 70 percent ethanol instead of water. Three to five times more creatinine concentration can be encompassed within linear portion of calibration curve.

  2. Tympanometry in infants: a study of the sensitivity and specificity of 226-Hz and 1,000-Hz probe tones.

    PubMed

    Carmo, Michele Picanço; Costa, Nayara Thais de Oliveira; Momensohn-Santos, Teresa Maria

    2013-10-01

    Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we identified 36 articles in the SciELO database, 11 in the Latin American and Caribbean Literature on the Health Sciences (LILACS) database, 199 in MEDLINE, 0 in the Cochrane database, 16 in ISI Web of Knowledge, and 185 in the Scopus database. We excluded 433 articles because they did not fit the selection criteria, leaving 14 publications that were analyzed in their entirety. Conclusions The 1,000-Hz tone test has greater sensitivity and specificity for the correct identification of tympanometric curve changes. However, it is necessary to clarify the doubts that still exist regarding the use of this test frequency. Improved methods for rating curves, standardization of normality criteria, and the types of curves found in infants should be addressed.

  3. Tympanometry in Infants: A Study of the Sensitivity and Specificity of 226-Hz and 1,000-Hz Probe Tones

    PubMed Central

    Carmo, Michele Picanço; Costa, Nayara Thais de Oliveira; Momensohn-Santos, Teresa Maria

    2013-01-01

    Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we identified 36 articles in the SciELO database, 11 in the Latin American and Caribbean Literature on the Health Sciences (LILACS) database, 199 in MEDLINE, 0 in the Cochrane database, 16 in ISI Web of Knowledge, and 185 in the Scopus database. We excluded 433 articles because they did not fit the selection criteria, leaving 14 publications that were analyzed in their entirety. Conclusions The 1,000-Hz tone test has greater sensitivity and specificity for the correct identification of tympanometric curve changes. However, it is necessary to clarify the doubts that still exist regarding the use of this test frequency. Improved methods for rating curves, standardization of normality criteria, and the types of curves found in infants should be addressed. PMID:25992044

  4. Model-based POD study of manual ultrasound inspection and sensitivity analysis using metamodel

    NASA Astrophysics Data System (ADS)

    Ribay, Guillemette; Artusi, Xavier; Jenson, Frédéric; Reece, Christopher; Lhuillier, Pierre-Emile

    2016-02-01

    The reliability of NDE can be quantified by using the Probability of Detection (POD) approach. Former studies have shown the potential of the model-assisted POD (MAPOD) approach to replace expensive experimental determination of POD curves. In this paper, we make use of CIVA software to determine POD curves for a manual ultrasonic inspection of a heavy component, for which a whole experimental POD campaign was not available. The influential parameters were determined by expert analysis. The semi-analytical models used in CIVA for wave propagation and beam-defect interaction have been validated in the range of variation of the influential parameters by comparison with finite element modelling (Athena). The POD curves are computed for « hit/miss » and « â versus a » analysis. The verification of Berens hypothesis is evaluated by statistical tools. A sensitivity study is performed to measure the relative influence of parameters on the defect response amplitude variance, using the Sobol sensitivity index. A meta-model is also built to reduce computing cost and enhance the precision of estimated index.

  5. Effects of fatigue on driving performance under different roadway geometries: a simulator study.

    PubMed

    Du, Hongji; Zhao, Xiaohua; Zhang, Xingjian; Zhang, Yunlong; Rong, Jian

    2015-01-01

    This article examines the effects of fatigue on driving performance under different roadway geometries using a driving simulator. Twenty-four participants each completed a driving scenario twice: while alert and while experiencing fatigue. The driving scenario was composed of straight road segments and curves; there were 6 curves with 3 radius values (i.e., 200, 500, and 800 m) and 2 turning directions (i.e., left and right). Analysis was conducted on driving performance measures such as longitudinal speed, steering wheel movements, and lateral position. RESULTS confirmed that decremental changes in driving performance due to fatigue varied among road conditions. On straight segments, drivers' abilities to steer and maintain lane position were impaired, whereas on curves we found decremental changes in the quality of longitudinal speed as well as steering control and keeping the vehicle in the lane. Moreover, the effects of fatigue on driving performance were relative to the radius and direction of the curve. Fatigue impaired drivers' abilities to control the steering wheel, and the impairment proved more obvious on curves. The degree varied significantly as the curve radius changed. Drivers tended to drive closer to the right side due to fatigue, and the impairment in maintaining lane position became more obvious as the right-turn curve radius decreased. Driver fatigue has detrimental effects on driving performance, and the effects differ under different roadway geometries.

  6. An Image Encryption Algorithm Utilizing Julia Sets and Hilbert Curves

    PubMed Central

    Sun, Yuanyuan; Chen, Lina; Xu, Rudan; Kong, Ruiqing

    2014-01-01

    Image encryption is an important and effective technique to protect image security. In this paper, a novel image encryption algorithm combining Julia sets and Hilbert curves is proposed. The algorithm utilizes Julia sets’ parameters to generate a random sequence as the initial keys and gets the final encryption keys by scrambling the initial keys through the Hilbert curve. The final cipher image is obtained by modulo arithmetic and diffuse operation. In this method, it needs only a few parameters for the key generation, which greatly reduces the storage space. Moreover, because of the Julia sets’ properties, such as infiniteness and chaotic characteristics, the keys have high sensitivity even to a tiny perturbation. The experimental results indicate that the algorithm has large key space, good statistical property, high sensitivity for the keys, and effective resistance to the chosen-plaintext attack. PMID:24404181

  7. Language evaluation protocol for children aged 2 months to 23 months: analysis of sensitivity and specificity.

    PubMed

    Labanca, Ludimila; Alves, Cláudia Regina Lindgren; Bragança, Lidia Lourenço Cunha; Dorim, Diego Dias Ramos; Alvim, Cristina Gonçalves; Lemos, Stela Maris Aguiar

    2015-01-01

    To establish cutoff points for the analysis of the Behavior Observation Form (BOF) of children in the ages of 2 to 23 months and evaluate the sensitivity and specificity by age group and domains (Emission, Reception, and Cognitive Aspects of Language). The sample consisted of 752 children who underwent BOF. Each child was classified as having appropriate language development for the age or having possible risk of language impairment. Performance Indicators (PI) were calculated in each domain as well as the overall PI in all domains. The values for sensitivity and specificity were also calculated. The cutoff points for possible risk of language impairment for each domain and each age group were obtained using the receiver operating characteristics curve. The results of the study revealed that one-third of the assessed children have a risk of language impairment in the first two years of life. The analysis of BOF showed high sensitivity (>90%) in all categories and in all age groups; however, the chance of false-positive results was higher than 20% in the majority of aspects evaluated. It was possible to establish the cutoff points for all categories and age groups with good correlation between sensitivity and specificity, except for the age group of 2 to 6 months. This study provides important contributions to the discussion on the evaluation of the language development of children younger than 2 years.

  8. Predicting the risk of malignancy in adnexal masses based on the Simple Rules from the International Ovarian Tumor Analysis group.

    PubMed

    Timmerman, Dirk; Van Calster, Ben; Testa, Antonia; Savelli, Luca; Fischerova, Daniela; Froyman, Wouter; Wynants, Laure; Van Holsbeke, Caroline; Epstein, Elisabeth; Franchi, Dorella; Kaijser, Jeroen; Czekierdowski, Artur; Guerriero, Stefano; Fruscio, Robert; Leone, Francesco P G; Rossi, Alberto; Landolfo, Chiara; Vergote, Ignace; Bourne, Tom; Valentin, Lil

    2016-04-01

    Accurate methods to preoperatively characterize adnexal tumors are pivotal for optimal patient management. A recent metaanalysis concluded that the International Ovarian Tumor Analysis algorithms such as the Simple Rules are the best approaches to preoperatively classify adnexal masses as benign or malignant. We sought to develop and validate a model to predict the risk of malignancy in adnexal masses using the ultrasound features in the Simple Rules. This was an international cross-sectional cohort study involving 22 oncology centers, referral centers for ultrasonography, and general hospitals. We included consecutive patients with an adnexal tumor who underwent a standardized transvaginal ultrasound examination and were selected for surgery. Data on 5020 patients were recorded in 3 phases from 2002 through 2012. The 5 Simple Rules features indicative of a benign tumor (B-features) and the 5 features indicative of malignancy (M-features) are based on the presence of ascites, tumor morphology, and degree of vascularity at ultrasonography. Gold standard was the histopathologic diagnosis of the adnexal mass (pathologist blinded to ultrasound findings). Logistic regression analysis was used to estimate the risk of malignancy based on the 10 ultrasound features and type of center. The diagnostic performance was evaluated by area under the receiver operating characteristic curve, sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), negative predictive value (NPV), and calibration curves. Data on 4848 patients were analyzed. The malignancy rate was 43% (1402/3263) in oncology centers and 17% (263/1585) in other centers. The area under the receiver operating characteristic curve on validation data was very similar in oncology centers (0.917; 95% confidence interval, 0.901-0.931) and other centers (0.916; 95% confidence interval, 0.873-0.945). Risk estimates showed good calibration. In all, 23% of patients in the validation data set had a very low estimated risk (<1%) and 48% had a high estimated risk (≥30%). For the 1% risk cutoff, sensitivity was 99.7%, specificity 33.7%, LR+ 1.5, LR- 0.010, PPV 44.8%, and NPV 98.9%. For the 30% risk cutoff, sensitivity was 89.0%, specificity 84.7%, LR+ 5.8, LR- 0.13, PPV 75.4%, and NPV 93.9%. Quantification of the risk of malignancy based on the Simple Rules has good diagnostic performance both in oncology centers and other centers. A simple classification based on these risk estimates may form the basis of a clinical management system. Patients with a high risk may benefit from surgery by a gynecological oncologist, while patients with a lower risk may be managed locally. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Measurement of radioactivity concentration in blood by using newly developed ToT LuAG-APD based small animal PET tomograph.

    PubMed

    Malik, Azhar H; Shimazoe, Kenji; Takahashi, Hiroyuki

    2013-01-01

    In order to obtain plasma time activity curve (PTAC), input function for almost all quantitative PET studies, patient blood is sampled manually from the artery or vein which has various drawbacks. Recently a novel compact Time over Threshold (ToT) based Pr:LuAG-APD animal PET tomograph is developed in our laboratory which has 10% energy resolution, 4.2 ns time resolution and 1.76 mm spatial resolution. The measured value of spatial resolution shows much promise for imaging the blood vascular, i.e; artery of diameter 2.3-2.4mm, and hence, to measure PTAC for quantitative PET studies. To find the measurement time required to obtain reasonable counts for image reconstruction, the most important parameter is the sensitivity of the system. Usually small animal PET systems are characterized by using a point source in air. We used Electron Gamma Shower 5 (EGS5) code to simulate a point source at different positions inside the sensitive volume of tomograph and the axial and radial variations in the sensitivity are studied in air and phantom equivalent water cylinder. An average sensitivity difference of 34% in axial direction and 24.6% in radial direction is observed when point source is displaced inside water cylinder instead of air.

  10. Interindividual variation in thermal sensitivity of maximal sprint speed, thermal behavior, and resting metabolic rate in a lizard.

    PubMed

    Artacho, Paulina; Jouanneau, Isabelle; Le Galliard, Jean-François

    2013-01-01

    Studies of the relationship of performance and behavioral traits with environmental factors have tended to neglect interindividual variation even though quantification of this variation is fundamental to understanding how phenotypic traits can evolve. In ectotherms, functional integration of locomotor performance, thermal behavior, and energy metabolism is of special interest because of the potential for coadaptation among these traits. For this reason, we analyzed interindividual variation, covariation, and repeatability of the thermal sensitivity of maximal sprint speed, preferred body temperature, thermal precision, and resting metabolic rate measured in ca. 200 common lizards (Zootoca vivipara) that varied by sex, age, and body size. We found significant interindividual variation in selected body temperatures and in the thermal performance curve of maximal sprint speed for both the intercept (expected trait value at the average temperature) and the slope (measure of thermal sensitivity). Interindividual differences in maximal sprint speed across temperatures, preferred body temperature, and thermal precision were significantly repeatable. A positive relationship existed between preferred body temperature and thermal precision, implying that individuals selecting higher temperatures were more precise. The resting metabolic rate was highly variable but was not related to thermal sensitivity of maximal sprint speed or thermal behavior. Thus, locomotor performance, thermal behavior, and energy metabolism were not directly functionally linked in the common lizard.

  11. Functional magnetic resonance imaging activation detection: fuzzy cluster analysis in wavelet and multiwavelet domains.

    PubMed

    Jahanian, Hesamoddin; Soltanian-Zadeh, Hamid; Hossein-Zadeh, Gholam-Ali

    2005-09-01

    To present novel feature spaces, based on multiscale decompositions obtained by scalar wavelet and multiwavelet transforms, to remedy problems associated with high dimension of functional magnetic resonance imaging (fMRI) time series (when they are used directly in clustering algorithms) and their poor signal-to-noise ratio (SNR) that limits accurate classification of fMRI time series according to their activation contents. Using randomization, the proposed method finds wavelet/multiwavelet coefficients that represent the activation content of fMRI time series and combines them to define new feature spaces. Using simulated and experimental fMRI data sets, the proposed feature spaces are compared to the cross-correlation (CC) feature space and their performances are evaluated. In these studies, the false positive detection rate is controlled using randomization. To compare different methods, several points of the receiver operating characteristics (ROC) curves, using simulated data, are estimated and compared. The proposed features suppress the effects of confounding signals and improve activation detection sensitivity. Experimental results show improved sensitivity and robustness of the proposed method compared to the conventional CC analysis. More accurate and sensitive activation detection can be achieved using the proposed feature spaces compared to CC feature space. Multiwavelet features show superior detection sensitivity compared to the scalar wavelet features. (c) 2005 Wiley-Liss, Inc.

  12. Chemical cues from fish heighten visual sensitivity in larval crabs through changes in photoreceptor structure and function.

    PubMed

    Charpentier, Corie L; Cohen, Jonathan H

    2015-11-01

    Several predator avoidance strategies in zooplankton rely on the use of light to control vertical position in the water column. Although light is the primary cue for such photobehavior, predator chemical cues or kairomones increase swimming responses to light. We currently lack a mechanistic understanding for how zooplankton integrate visual and chemical cues to mediate phenotypic plasticity in defensive photobehavior. In marine systems, kairomones are thought to be amino sugar degradation products of fish body mucus. Here, we demonstrate that increasing concentrations of fish kairomones heightened sensitivity of light-mediated swimming behavior for two larval crab species (Rhithropanopeus harrisii and Hemigrapsus sanguineus). Consistent with these behavioral results, we report increased visual sensitivity at the retinal level in larval crab eyes directly following acute (1-3 h) kairomone exposure, as evidenced electrophysiologically from V-log I curves and morphologically from wider, shorter rhabdoms. The observed increases in visual sensitivity do not correspond with a decline in temporal resolution, because latency in electrophysiological responses actually increased after kairomone exposure. Collectively, these data suggest that phenotypic plasticity in larval crab photobehavior is achieved, at least in part, through rapid changes in photoreceptor structure and function. © 2015. Published by The Company of Biologists Ltd.

  13. Decision making for pancreatic resection in patients with intraductal papillary mucinous neoplasms.

    PubMed

    Xu, Bin; Ding, Wei-Xing; Jin, Da-Yong; Wang, Dan-Song; Lou, Wen-Hui

    2013-03-07

    To identify a practical approach for preoperative decision-making in patients with intraductal papillary mucinous neoplasms (IPMNs) of the pancreas. Between March 1999 and November 2006, the clinical characteristics, pathological data and computed tomography/magnetic resonance imaging (CT/MRI) of 54 IPMNs cases were retrieved and analyzed. The relationships between the above data and decision-making for pancreatic resection were analyzed using SPSS 13.0 software. Univariate analysis of risk factors for malignant or invasive IPMNs was performed with regard to the following variables: carcinoembryonic antigen, carbohydrate antigen 19-9 (CA19-9) and the characteristics from CT/MRI images. Receiver operating characteristic (ROC) curve analysis for pancreatic resection was performed using significant factors from the univariate analysis. CT/MRI images, including main and mixed duct IPMNs, tumor size > 30 mm or a solid component appearance in the lesion, and preoperative serum CA19-9 > 37 U/mL had good predictive value for determining pancreatic resection (P < 0.05), but with limitations. Combining the above factors (CT/MRI images and CA19-9) improved the accuracy and sensitivity for determining pancreatic resection in IPMNs. Using ROC analysis, the area under the curve reached 0.893 (P < 0.01, 95%CI: 0.763-1.023), with a sensitivity, specificity, positive predictive value and negative predictive value of 95.2%, 83.3%, 95.2% and 83.3%, respectively. Combining preoperative CT/MRI images and CA19-9 level may provide useful information for surgical decision-making in IPMNs.

  14. FEV1 Is a Better Predictor of Mortality than FVC: The PLATINO Cohort Study

    PubMed Central

    Menezes, Ana Maria B.; Pérez-Padilla, Rogelio; Wehrmeister, Fernando César; Lopez-Varela, Maria Victorina; Muiño, Adriana; Valdivia, Gonzalo; Lisboa, Carmen; Jardim, José Roberto B.; de Oca, Maria Montes; Talamo, Carlos; Bielemann, Renata; Gazzotti, Mariana; Laurenti, Ruy; Celli, Bartolomé; Victora, Cesar G.

    2014-01-01

    Objective To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort. Materials/Patients and Methods Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated. Results Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVC

  15. Audiometric asymmetry and tinnitus laterality.

    PubMed

    Tsai, Betty S; Sweetow, Robert W; Cheung, Steven W

    2012-05-01

    To identify an optimal audiometric asymmetry index for predicting tinnitus laterality. Retrospective medical record review. Data from adult tinnitus patients (80 men and 44 women) were extracted for demographic, audiometric, tinnitus laterality, and related information. The main measures were sensitivity, specificity, positive predictive value (PPV), and receiver operating characteristic (ROC) curves. Three audiometric asymmetry indices were constructed using one, two, or three frequency elements to compute the average interaural threshold difference (aITD). Tinnitus laterality predictive performance of a particular index was assessed by increasing the cutoff or minimum magnitude of the aITD from 10 to 35 dB in 5-dB steps to determine its ROC curve. Single frequency index performance was inferior to the other two (P < .05). Double and triple frequency indices were indistinguishable (P > .05). Two adjoining frequency elements with aITD ≥ 15 dB performed optimally for predicting tinnitus laterality (sensitivity = 0.59, specificity = 0.71, and PPV = 0.76). Absolute and relative magnitudes of hearing loss in the poorer ear were uncorrelated with tinnitus distress. An optimal audiometric asymmetry index to predict tinnitus laterality is one whereby 15 dB is the minimum aITD of two adjoining frequencies, inclusive of the maximal ITD. Tinnitus laterality dependency on magnitude of interaural asymmetry may inform design and interpretation of neuroimaging studies. Monaural acoustic tinnitus therapy may be an initial consideration for asymmetric hearing loss meeting the criterion of aITD ≥ 15 dB. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  16. Transesophageal Echocardiographic Assessment of Pulmonary Artery-to-Ascending Aorta Ratio for the Detection of Pulmonary Hypertension in Cardiac Surgical Patients.

    PubMed

    Narendra Kumar, Karthik; Singh, Naveen G; P S, Nagaraja; Patil, Thimmangouda A; N, Manjunath

    2017-10-01

    The objective of the study was to investigate if the main pulmonary artery (mPA)-to-ascending aorta (AscAo), (mPA:AscAo) ratio could serve as a screening tool in identifying pulmonary artery hypertension (PAH). A prospective observational study. Tertiary care center, university hospital. Fifty-four adult patients undergoing off-pump coronary artery bypass grafting surgery (OPCAB). mPA and AscAo transverse diameters were measured by transesophageal echocardiography (TEE) and the mean pulmonary arterial pressures (mPAP) were recorded simultaneously using a pulmonary artery catheter. mPA:AscAo ratio demonstrated significant linear correlation with mPAP measured by pulmonary artery catheterization (ie, r = 0.61, confidence interval [CI] = 0.5352-0.6736, p < 0.0001). Receiver operating characteristic curves were performed to evaluate sensitivity and specificity of mPA:AscAo ratio ≥1 for diagnosing PAH (mPAP ≥25 mmHg). Area under the curve for mPA:AscAo ratio was 0.91 (95% CI, 0.869-0.936, p < 0.0001), with a sensitivity of 84.27%, specificity of 83.92%, positive-predictive value of 87.6% and negative-predictive value of 81.1% for a mPAP ≥25 mmHg. The ratio of mPA:AscAo is a simple, reliable, and reproducible method that can be obtained through TEE, which guides the clinician to screen patients with PAH. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Accuracy of Percutaneous Core Biopsy in the Diagnosis of Small Renal Masses (≤ 4.0 cm): A Meta-analysis.

    PubMed

    He, Qiqi; Wang, Hanzhang; Kenyon, Jonathan; Liu, Guiming; Yang, Li; Tian, Junqiang; Yue, Zhongjin; Wang, Zhiping

    2015-01-01

    To use meta-analysis to determine the accuracy of percutaneous core needle biopsy in the diagnosis of small renal masses (SMRs ≤ 4.0 cm). Studies were identified by searching PubMed, Embase, and the Cochrane Library database up to March 2013. Two of the authors independently assessed the study quality using QUADAS-2 tool and extracted data that met the inclusion criteria. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and also summary receiver operating characteristic (SROC) curve were investigated and draw. Deek's funnel plot was used to evaluate the publication bias. A total of 9 studies with 788 patients (803 biopsies) were included. Failed biopsies without repeated or aborted from follow-up/surgery result were excluded (232 patients and 353 biopsies). For all cases, the pooled sensitivity was 94.0% (95% CI: 91.0%, 95.0%), the pooled positive likelihood was 22.57 (95 % CI: 9.20-55.34), the pooled negative likelihood was 0.09 (95 % CI: 0.06-0.13), the pooled DOR was 296.52(95 % CI: 99. 42-884.38). The area under the curve of SROC analysis was 0.959 ± 0.0254. Imaging-guided percutaneous core needle biopsy of small renal masses (SMRs ≤ 4.0 cm) is highly accurate to malignant tumor diagnosis with unknown metastatic status and could be offered to some patients after clinic judgment prior to surgical intervention consideration.

  18. Improving and Assessing Planet Sensitivity of the GPI Exoplanet Survey with a Forward Model Matched Filter

    NASA Astrophysics Data System (ADS)

    Ruffio, Jean-Baptiste; Macintosh, Bruce; Wang, Jason J.; Pueyo, Laurent; Nielsen, Eric L.; De Rosa, Robert J.; Czekala, Ian; Marley, Mark S.; Arriaga, Pauline; Bailey, Vanessa P.; Barman, Travis; Bulger, Joanna; Chilcote, Jeffrey; Cotten, Tara; Doyon, Rene; Duchêne, Gaspard; Fitzgerald, Michael P.; Follette, Katherine B.; Gerard, Benjamin L.; Goodsell, Stephen J.; Graham, James R.; Greenbaum, Alexandra Z.; Hibon, Pascale; Hung, Li-Wei; Ingraham, Patrick; Kalas, Paul; Konopacky, Quinn; Larkin, James E.; Maire, Jérôme; Marchis, Franck; Marois, Christian; Metchev, Stanimir; Millar-Blanchaer, Maxwell A.; Morzinski, Katie M.; Oppenheimer, Rebecca; Palmer, David; Patience, Jennifer; Perrin, Marshall; Poyneer, Lisa; Rajan, Abhijith; Rameau, Julien; Rantakyrö, Fredrik T.; Savransky, Dmitry; Schneider, Adam C.; Sivaramakrishnan, Anand; Song, Inseok; Soummer, Remi; Thomas, Sandrine; Wallace, J. Kent; Ward-Duong, Kimberly; Wiktorowicz, Sloane; Wolff, Schuyler

    2017-06-01

    We present a new matched-filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar point-spread function (PSF) is first subtracted using a Karhunen-Loéve image processing (KLIP) algorithm with angular and spectral differential imaging (ADI and SDI). The KLIP-induced distortion of the astrophysical signal is included in the matched-filter template by computing a forward model of the PSF at every position in the image. To optimize the performance of the algorithm, we conduct extensive planet injection and recovery tests and tune the exoplanet spectra template and KLIP reduction aggressiveness to maximize the signal-to-noise ratio (S/N) of the recovered planets. We show that only two spectral templates are necessary to recover any young Jovian exoplanets with minimal S/N loss. We also developed a complete pipeline for the automated detection of point-source candidates, the calculation of receiver operating characteristics (ROC), contrast curves based on false positives, and completeness contours. We process in a uniform manner more than 330 data sets from the Gemini Planet Imager Exoplanet Survey and assess GPI typical sensitivity as a function of the star and the hypothetical companion spectral type. This work allows for the first time a comparison of different detection algorithms at a survey scale accounting for both planet completeness and false-positive rate. We show that the new forward model matched filter allows the detection of 50% fainter objects than a conventional cross-correlation technique with a Gaussian PSF template for the same false-positive rate.

  19. Clinical Prediction Rule for Declines in Activities of Daily Living at 6 Months After Surgery for Hip Fracture Repair.

    PubMed

    Tanaka, Ryo; Umehara, Takuya; Fujimura, Takafumi; Ozawa, Junya

    2016-12-01

    To develop and assess a clinical prediction rule (CPR) to predict declines in activities of daily living (ADL) at 6 months after surgery for hip fracture repair. Prospective, cohort study. From hospital to home. Patients (N=104) with hip fractures after surgery. Not applicable. ADL were assessed using the Barthel Index at 6 months after surgery. At 6 months after surgery, 86 patients (82.6%) were known to be alive, 1 patient (1.0%) had died, and 17 (16.3%) were lost to follow-up. Thirty-two patients (37.2%) did not recover their ADL at 6 months after surgery to levels before fracture. The classification and regression trees methodology was used to develop 2 models to predict a decline in ADL: (1) model 1 included age, type of fracture, and care level before fracture (sensitivity=75.0%, specificity=81.5%, positive predictive value=70.6%, positive likelihood ratio=4.050); and (2) model 2 included the degree of independence 2 weeks postsurgery for ADL chair transfer, ADL ambulation, and age (sensitivity=65.6%, specificity=87.0%, positive predictive value=75.0%, positive likelihood ratio=5.063). The areas under the receiver operating characteristic curves of both CPR models were .825 (95% confidential interval, .728-.923) and .790 (95% confidence interval, .683-.897), respectively. CPRs with moderate accuracy were developed to predict declines in ADL at 6 months after surgery for hip fracture repair. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. [Comparison of the CMV antigenemia test and CMV-DNA PCR results in solid organ transplant recipients].

    PubMed

    Özkarata, Emre; Özkarataş, Emre; Özbek, Ö Alpay; Avkan Oğuz, Vildan; Sayıner, A Arzu

    2016-01-01

    Cytomegalovirus (CMV) infection is among the most common important viral infections in solid organ transplant (SOT) recipients. Diagnostic tests for detecting CMV replication are widely used for this group of patients, however there is no clear agreement on the cut-off levels for interpretation of clinical decisions especially when the low level of viral load is detected. In this study, CMV pp65 antigenemia test results were compared with plasma CMV-DNA levels detected by quantitative real-time polymerase chain reaction (qPCR) in samples of kidney and liver transplant recipients in the Central Laboratory of Dokuz Eylul University Hospital between 2011 and 2013, and the correlation between these two tests and viral load equivalent to antigenemia positivity were determined. In the study, pp65 antigenemia and CMV-DNA qPCR results were evaluated retrospectively. The samples from the same patients were included if the time between antigenemia and CMV-DNA qPCR tests were less than 48 hours. SPSS v15.0 was used for correlation, regression and ROC curve analysis. The results of the 217 samples collected from 100 patients (59 male, 41 female; age range: 16-71, mean age: 46 ± 13 years), 36 liver and 64 kidney recipients were evaluated in the study. Of the patients 80% were CMV IgM negative, IgG positive; 1% was CMV IgG and IgM positive; 2% were CMV IgM and IgG negative, while for 17 patients serological results could not be reached. CMV pp65 antigenemia and CMV-DNA were both negative in 102 (47%) samples, while both were positive in 37 (17%) samples. The single sample from a case with CMV IgM and IgG positivity yielded negative results for both antigenemia and CMV-DNA tests. In 78 samples antigenemia were negative and CMV-DNA qPCR were positive, while there were no samples with antigenemia positive and qPCR negative. Mean values of antigenemia and qPCR tests were 23 positive cells/200.000 leukocytes (range: 1 to 230 positive cells) and 12.595 copies/ml (range: 180 to 106.311 copies/ml), respectively. There was a significant correlation between antigenemia and qPCR results among the samples that were positive by both assays (r= 0.785). ROC curve analysis showed that CMV viral load of 205 copies/ml in plasma corresponds to ≥ 1 pp65 antigen positive cells per 200.000 leukocytes (sensitivity: 91.7%, specificity: 90.3%). Higher analytical sensitivity of qPCR test can be explained by the results of CMV-DNA PCR positive and antigenemia negative samples. Non-existence of samples with antigen positive and PCR negative results supported this finding. ROC analysis showed that any sample with CMV-DNA qPCR result less than 205 copies/ml, could be accepted as pp65 antigenemia negative. This viral load value is valid only for the studied patient group and assays, therefore could be changed according to study population and tests.

  1. Using Bioassays and Species Sensitivity Distributions to Assess Herbicide Toxicity towards Benthic Diatoms

    PubMed Central

    Larras, Floriane; Bouchez, Agnès; Rimet, Frédéric; Montuelle, Bernard

    2012-01-01

    Although benthic diatoms are widely used in ecological studies of aquatic systems, there is still a dearth of data concerning species sensitivities towards several contaminants. Within the same community, different species may respond differently depending on their physiological and ecological characteristics. This lack of knowledge makes specific appropriate risk assessment impossible. To find out whether species sensitivity distribution (SSD) could be used to estimate the risk of herbicide toxicity for diatoms, we need to know whether their sensitivity depends on their physiological and ecological characteristics. We carried out single-species bioassays on 11 diatom species exposed to 8 herbicides. Dose-responses relationships were used to extrapolate the Effective Concentration 5 (EC5) and the Effective Concentration 50 (EC50) for each exposure. These data were used to fit a SSD curve for each herbicide, and to determine the Hazardous concentration 5 (HC5) and 50 (HC50). Our results revealed a high level of variability of the sensitivity in the set of species tested. For photosystem-II inhibitor (PSII) herbicides, diatoms species displayed a typical grouping of sensitivity levels consistent with their trophic mode and their ecological guild. N-heterotroph and “motile” guild species were more tolerant of PSII inhibitors, while N-autotroph and “low profile” guild species were more sensitive. Comprehensive SSD curves were obtained for 5 herbicides, but not for sulfonylurea herbicides or for dimetachlor, which had toxicity levels that were below the range of concentration tested. The SSD curves provided the following ranking of toxicity: diuron> terbutryn> isoproturon> atrazine> metolachlor. The HC that affected 5% of the species revealed that, even at the usual environmental concentrations of herbicides, diatom assemblages could be affected, especially by isoproturon, terbutryn, and diuron. PMID:22952981

  2. A receiver operated curve-based evaluation of change in sensitivity and specificity of cotinine urinalysis for detecting active tobacco use.

    PubMed

    Balhara, Yatan Pal Singh; Jain, Raka

    2013-01-01

    Tobacco use has been associated with various carcinomas including lung, esophagus, larynx, mouth, throat, kidney, bladder, pancreas, stomach, and cervix. Biomarkers such as concentration of cotinine in the blood, urine, or saliva have been used as objective measures to distinguish nonusers and users of tobacco products. A change in the cut-off value of urinary cotinine to detect active tobacco use is associated with a change in sensitivity and sensitivity of detection. The current study aimed at assessing the impact of using different cut-off thresholds of urinary cotinine on sensitivity and specificity of detection of smoking and smokeless tobacco product use among psychiatric patients. All the male subjects attending the psychiatry out-patient department of the tertiary care multispecialty teaching hospital constituted the sample frame for the current study in a cross-sectionally. Quantitative urinary cotinine assay was done by using ELISA kits of Calbiotech. Inc., USA. We used the receiver operating characteristic (ROC) curve to assess the sensitivity and specificity of various cut-off values of urinary cotinine to identify active smokers and users of smokeless tobacco products. ROC analysis of urinary cotinine levels in detection of self-reported smoking provided the area under curve (AUC) of 0.434. Similarly, the ROC analysis of urinary cotinine levels in detection of self-reported smoking revealed AUC of 0.44. The highest sensitivity and specificity of 100% for smoking were detected at the urinary cut-off value greater than or equal to 2.47 ng/ml. The choice of cut-off value of urinary cotinine used to distinguish nonusers form active users of tobacco products impacts the sensitivity as well as specificity of detection.

  3. Automated Interpretation of Blood Culture Gram Stains by Use of a Deep Convolutional Neural Network.

    PubMed

    Smith, Kenneth P; Kang, Anthony D; Kirby, James E

    2018-03-01

    Microscopic interpretation of stained smears is one of the most operator-dependent and time-intensive activities in the clinical microbiology laboratory. Here, we investigated application of an automated image acquisition and convolutional neural network (CNN)-based approach for automated Gram stain classification. Using an automated microscopy platform, uncoverslipped slides were scanned with a 40× dry objective, generating images of sufficient resolution for interpretation. We collected 25,488 images from positive blood culture Gram stains prepared during routine clinical workup. These images were used to generate 100,213 crops containing Gram-positive cocci in clusters, Gram-positive cocci in chains/pairs, Gram-negative rods, or background (no cells). These categories were targeted for proof-of-concept development as they are associated with the majority of bloodstream infections. Our CNN model achieved a classification accuracy of 94.9% on a test set of image crops. Receiver operating characteristic (ROC) curve analysis indicated a robust ability to differentiate between categories with an area under the curve of >0.98 for each. After training and validation, we applied the classification algorithm to new images collected from 189 whole slides without human intervention. Sensitivity and specificity were 98.4% and 75.0% for Gram-positive cocci in chains and pairs, 93.2% and 97.2% for Gram-positive cocci in clusters, and 96.3% and 98.1% for Gram-negative rods. Taken together, our data support a proof of concept for a fully automated classification methodology for blood-culture Gram stains. Importantly, the algorithm was highly adept at identifying image crops with organisms and could be used to present prescreened, classified crops to technologists to accelerate smear review. This concept could potentially be extended to all Gram stain interpretive activities in the clinical laboratory. Copyright © 2018 American Society for Microbiology.

  4. Comparative evaluation of GPR versus APRI and FIB-4 in predicting different levels of liver fibrosis of chronic hepatitis B.

    PubMed

    Liu, D-P; Lu, W; Zhang, Z-Q; Wang, Y-B; Ding, R-R; Zhou, X-L; Huang, D; Li, X-F

    2018-05-01

    It is of great significance to develop and evaluate noninvasive indexes predicting the level of liver fibrosis. The aim of this study was to comparatively evaluate gamma-glutamyl transpeptidase-to-platelet ratio (GPR) versus aspartate aminotransferase-to-platelet ratio index (APRI) and fibrosis index based on 4 factors (FIB-4) in predicting different levels of liver fibrosis of chronic hepatitis B (CHB) within the framework of HBeAg-positive and HBeAg-negative patients. A total of 1157 HBeAg-positive and 859 HBeAg-negative CHB patients were enrolled, among whom the pathological stage ≥S2, ≥S3, ≥S4 were defined as significant fibrosis, extensive fibrosis and cirrhosis, respectively. Receiver operating characteristic (ROC) curves were used to evaluate the performance of GPR, APRI and FIB-4 in predicting different levels of liver fibrosis. In HBeAg-positive patients, the area under ROC curves (AUROCs) of GPR in predicting extensive fibrosis and cirrhosis were both significantly larger than those of APRI (P = .0001 and P < .0001). In HBeAg-negative patients, the AUROCs of GPR in predicting significant fibrosis and cirrhosis were significantly larger than those of FIB-4 (P = .0006 and P = .0041). The AUROC of GPR in predicting extensive fibrosis was significantly larger than that of APRI and FIB-4 (P = .0320 and P = .0018). Using a cut-off of GPR > 0.500 as standard, the sensitivities and specificities of GPR in predicting significant fibrosis in HBeAg-positive patients were 59.6% and 81.2%, and for cirrhosis 80.9% and 63.8%, respectively; and those of HBeAg-negative patients were 60.3% and 78.3%, 84.5% and 66.1%, respectively. Regardless of HBeAg-positive or HBeAg-negative status, GPR had the best performance in predicting different levels of liver fibrosis. © 2017 John Wiley & Sons Ltd.

  5. Immunohistochemistry of cytokeratins 7, 8, 17, 18, and 19, and GLUT-1 aids differentiation of desmoplastic malignant mesothelioma from fibrous pleuritis.

    PubMed

    Horiuchi, Toshikatsu; Ogata, Sho; Tominaga, Susumu; Hiroi, Sadayuki; Kawahara, Kunimitsu; Hebisawa, Akira; Irei, Isao; Ito, Ichiro; Kameya, Toru; Tsujimura, Tohru; Nakano, Takashi; Nakanishi, Kuniaki; Kawai, Toshiaki

    2013-05-01

    It is difficult to distinguish desmoplastic malignant mesothelioma (DMM) from fibrous pleuritis (FP). We investigated the utility of immunohistochemistry as a way of differentiating between DMM and FP. We examined 11 DMMs and 46 FPs with the aid of antibodies against 18 cytokeratin (CK) subtypes, calponin, caldesmon, desmin, and GLUT-1. The best sensitivity and specificity cut-off values in the receiver operating characteristic curves (ROC) for CKs 7, 8, 17, 18, and 19, and GLUT-1 were each above 60%. When cases with either DMM or FP were partitioned by the staining score associated with the best sensitivity and specificity cut-off values in ROC, the incidence of a positive expression for CKs 7, 8, 17, 18, and 19, and GLUT-1 was significantly higher in DMM than in FP. In conclusion, immunohistochemistry for CKs 7, 8, 17, 18, and 19, and GLUT-1 may be useful, alongside histological characteristics, for separating DMM from FP.

  6. Protein microarray with horseradish peroxidase chemiluminescence for quantification of serum α-fetoprotein.

    PubMed

    Zhao, Yuanshun; Zhang, Yonghong; Lin, Dongdong; Li, Kang; Yin, Chengzeng; Liu, Xiuhong; Jin, Boxun; Sun, Libo; Liu, Jinhua; Zhang, Aiying; Li, Ning

    2015-10-01

    To develop and evaluate a protein microarray assay with horseradish peroxidase (HRP) chemiluminescence for quantification of α-fetoprotein (AFP) in serum from patients with hepatocellular carcinoma (HCC). A protein microarray assay for AFP was developed. Serum was collected from patients with HCC and healthy control subjects. AFP was quantified using protein microarray and enzyme-linked immunosorbent assay (ELISA). Serum AFP concentrations determined via protein microarray were positively correlated (r = 0.973) with those determined via ELISA in patients with HCC (n = 60) and healthy control subjects (n = 30). Protein microarray showed 80% sensitivity and 100% specificity for HCC diagnosis. ELISA had 83.3% sensitivity and 100% specificity. Protein microarray effectively distinguished between patients with HCC and healthy control subjects (area under ROC curve 0.974; 95% CI 0.000, 1.000). Protein microarray is a rapid, simple and low-cost alternative to ELISA for detecting AFP in human serum. © The Author(s) 2015.

  7. Multimodal intraoperative neuromonitoring in corrective surgery for adolescent idiopathic scoliosis: Evaluation of 354 consecutive cases

    PubMed Central

    Kundnani, Vishal K; Zhu, Lisa; Tak, HH; Wong, HK

    2010-01-01

    Background: Multimodal intraoperative neuromonitoring is recommended during corrective spinal surgery, and has been widely used in surgery for spinal deformity with successful outcomes. Despite successful outcomes of corrective surgery due to increased safety of the patients with the usage of spinal cord monitoring in many large spine centers, this modality has not yet achieved widespread popularity. We report the analysis of prospectively collected intraoperative neurophysiological monitoring data of 354 consecutive patients undergoing corrective surgery for adolescent idiopathic scoliosis (AIS) to establish the efficacy of multimodal neuromonitoring and to evaluate comparative sensitivity and specificity. Materials and Methods: The study group consisted of 354 (female = 309; male = 45) patients undergoing spinal deformity corrective surgery between 2004 and 2008. Patients were monitored using electrophysiological methods including somatosensory-evoked potentials and motor-evoked potentials simultaneously. Results: Mean age of patients was 13.6 years (±2.3 years). The operative procedures involved were instrumented fusion of the thoracic/lumbar/both curves, Baseline somatosensory-evoked potentials (SSEP) and neurogenic motor-evoked potentials (NMEP) were recorded successfully in all cases. Thirteen cases expressed significant alert to prompt reversal of intervention. All these 13 cases with significant alert had detectable NMEP alerts, whereas significant SSEP alert was detected in 8 cases. Two patients awoke with new neurological deficit (0.56%) and had significant intraoperative SSEP + NMEP alerts. There were no false positives with SSEP (high specificity) but 5 patients with false negatives with SSEP (38%) reduced its sensitivity. There was no false negative with NMEP but 2 of 13 cases were false positive with NMEP (15%). The specificity of SSEP (100%) is higher than NMEP (96%); however, the sensitivity of NMEP (100%) is far better than SSEP (51%). Due to these results, the overall sensitivity, specificity and positive predictive value of combined multimodality neuromonitoring in this adult deformity series was 100, 98.5 and 85%, respectively. Conclusion: Neurogenic motor-evoked potential (NMEP) monitoring appears to be superior to conventional SSEP monitoring for identifying evolving spinal cord injury. Used in conjunction, the sensitivity and specificity of combined neuromonitoring may reach up to 100%. Multimodality monitoring with SSEP + NMEP should be the standard of care. PMID:20165679

  8. Screening for anxiety disorders in patients with coronary artery disease.

    PubMed

    Bunevicius, Adomas; Staniute, Margarita; Brozaitiene, Julija; Pop, Victor J M; Neverauskas, Julius; Bunevicius, Robertas

    2013-03-11

    Anxiety disorders are prevalent and associated with poor prognosis in patients with coronary artery disease (CAD). However, studies examining screening of anxiety disorders in CAD patients are lacking. In the present study we evaluated the prevalence of anxiety disorders in patients with CAD and diagnostic utility of self-rating scales for screening of anxiety disorders. Five-hundred and twenty-three CAD patients not receiving psychotropic treatments at initiation of rehabilitation program completed self-rating scales (Hospital Anxiety and Depression Scale or HADS; Spielberger State-Anxiety Inventory or SSAI; and Spielberger Trait-Anxiety Inventory or STAI) and were interviewed for generalized anxiety disorder (GAD), social phobia, panic disorder and agoraphobia (Mini-International Neuropsychiatric Interview or MINI). Thirty-eight (7%) patients were diagnosed with anxiety disorder(s), including GAD (5%), social phobia (2%), agoraphobia (1%) and panic disorder (1%). Areas under the ROC curve of the HADS Anxiety subscale (HADS-A), STAI and SSAI for screening of any anxiety disorder were .81, .80 and .72, respectively. Optimal cut-off values for screening of any anxiety disorders were ≥ 8 for the HADS-A (sensitivity = 82%; specificity = 76%; and positive predictive value (PPV) = 21%); ≥ 45 for the STAI (sensitivity = 89%; specificity = 56%; and PPV = 14%); and ≥ 40 for the SSAI (sensitivity = 84%; specificity = 55%; PPV = 13%). In a subgroup of patients (n = 340) scoring below the optimal major depressive disorder screening cut-off value of HADS-Depression subscale (score <5), the HADS-A, STAI and SSAI had moderate-high sensitivity (range from 69% to 89%) and low PPVs (≤ 22%) for GAD and any anxiety disorders. Anxiety disorders are prevalent in CAD patients but can be reliably identified using self-rating scales. Anxiety self-rating scales had comparable sensitivities but the HADS-A had greater specificity and PPV when compared to the STAI and SSAI for screening of anxiety disorders. However, false positive rates were high, suggesting that patients with positive screening results should undergo psychiatric interview prior to initiating treatment for anxiety disorders and that routine use of anxiety self-rating scales for screening purposes can increase healthcare costs. Anxiety screening has incremental value to depression screening for identifying anxiety disorders.

  9. Clinical Decision Support System to Enhance Quality Control of Spirometry Using Information and Communication Technologies

    PubMed Central

    2014-01-01

    Background We recently demonstrated that quality of spirometry in primary care could markedly improve with remote offline support from specialized professionals. It is hypothesized that implementation of automatic online assessment of quality of spirometry using information and communication technologies may significantly enhance the potential for extensive deployment of a high quality spirometry program in integrated care settings. Objective The objective of the study was to elaborate and validate a Clinical Decision Support System (CDSS) for automatic online quality assessment of spirometry. Methods The CDSS was done through a three step process including: (1) identification of optimal sampling frequency; (2) iterations to build-up an initial version using the 24 standard spirometry curves recommended by the American Thoracic Society; and (3) iterations to refine the CDSS using 270 curves from 90 patients. In each of these steps the results were checked against one expert. Finally, 778 spirometry curves from 291 patients were analyzed for validation purposes. Results The CDSS generated appropriate online classification and certification in 685/778 (88.1%) of spirometry testing, with 96% sensitivity and 95% specificity. Conclusions Consequently, only 93/778 (11.9%) of spirometry testing required offline remote classification by an expert, indicating a potential positive role of the CDSS in the deployment of a high quality spirometry program in an integrated care setting. PMID:25600957

  10. Right recumbent position on gastric emptying of water evidenced by 13C breath testing

    PubMed Central

    Sanaka, Masaki; Urita, Yoshihisa; Yamamoto, Takatsugu; Shirai, Tsuguru; Kimura, Satoshi; Aoyagi, Hitoshi; Kuyama, Yasushi

    2013-01-01

    AIM: To compare the impact of the right recumbent position with the sitting position on gastric emptying of water. METHODS: In eight healthy male volunteers, the 13C acetate breath test was performed twice to assess gastric emptying of 100 mL tap water. Subjects were seated in one test and lying on their right side in the other. In both positions, pulmonary 13CO2 exhalation curves were obtained by plotting breath data against time. Percent gastric retention curves were created by analyzing data using the Wagner-Nelson protocol. RESULTS: No significant posture effect was found in pulmonary 13CO2 output curves (P = 0.2150), whereas a significant effect was seen in gastric retention curves (P = 0.0315). The percent retention values at 10 min and 15 min were significantly smaller when subjects were in the right recumbent position compared with the seated position (P < 0.05). Our results verified the accelerating effect of the right recumbent position on gastric emptying of non-nutritive solutions. Concerning clinical implications, this study suggests that placing patients with acute pain on their right side after oral administration of analgesic drugs in solution is justified as an effective practice for rapid pain relief. For patients with gastrointestinal reflux symptoms, sleeping in the right recumbent position may reduce nocturnal symptoms, as delayed gastric emptying can cause reflux symptoms. CONCLUSION: Gastric emptying of water occurs more quickly when a subject lies on the right side compared with sitting. PMID:23372358

  11. Measures of accuracy and performance of diagnostic tests.

    PubMed

    Drobatz, Kenneth J

    2009-05-01

    Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.

  12. A New Weighted Injury Severity Scoring System: Better Predictive Power for Pediatric Trauma Mortality.

    PubMed

    Shi, Junxin; Shen, Jiabin; Caupp, Sarah; Wang, Angela; Nuss, Kathryn E; Kenney, Brian; Wheeler, Krista K; Lu, Bo; Xiang, Henry

    2018-05-02

    An accurate injury severity measurement is essential for the evaluation of pediatric trauma care and outcome research. The traditional Injury Severity Score (ISS) does not consider the differential risks of the Abbreviated Injury Scale (AIS) from different body regions nor is it pediatric specific. The objective of this study was to develop a weighted injury severity scoring (wISS) system for pediatric blunt trauma patients with better predictive power than ISS. Based on the association between mortality and AIS from each of the six ISS body regions, we generated different weights for the component AIS scores used in the calculation of ISS. The weights and wISS were generated using the National Trauma Data Bank (NTDB). The Nationwide Emergency Department Sample (NEDS) was used to validate our main results. Pediatric blunt trauma patients less than 16 years were included, and mortality was the outcome. Discrimination (areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, concordance) and calibration (Hosmer-Lemeshow statistic) were compared between the wISS and ISS. The areas under the receiver operating characteristic curves from the wISS and ISS are 0.88 vs. 0.86 in ISS=1-74 and 0.77 vs. 0.64 in ISS=25-74 (p<0.0001). The wISS showed higher specificity, positive predictive value, negative predictive value, and concordance when they were compared at similar levels of sensitivity. The wISS had better calibration (smaller Hosmer-Lemeshow statistic) than the ISS (11.6 versus 19.7 for ISS=1-74 and 10.9 versus 12.6 for ISS= 25-74). The wISS showed even better discrimination with the NEDS. By weighting the AIS from different body regions, the wISS had significantly better predictive power for mortality than the ISS, especially in critically injured children.Level of Evidence and study typeLevel IV Prognostic/Epidemiological.

  13. Development of a Screening Tool for Predicting Adverse Outcomes of Gestational Diabetes Mellitus

    PubMed Central

    Park, Jee Soo; Kim, Deok Won; Kwon, Ja-Young; Park, Yong Won; Kim, Young Han; Cho, Hee Young

    2016-01-01

    Abstract Gestational diabetes mellitus (GDM) is a common disease in pregnancy causing maternal and fetal complications. To prevent these adverse outcomes, optimal screening and diagnostic criteria must be adequate, timely, and efficient. This study suggests a novel approach that is practical, efficient, and patient- and clinician-friendly in predicting adverse outcomes of GDM. The authors conducted a retrospective cohort study via medical record review of patients admitted between March 2001 and April 2013 at the Severance Hospital, Seoul, South Korea. Patients diagnosed by a conventional 2-step method were evaluated according to the presence of adverse outcomes (neonatal hypoglycemia, hyperbilirubinemia, and hyperinsulinemia; admission to the neonatal intensive care unit; large for gestational age; gestational insulin therapy; and gestational hypertension). Of 802 women who had an abnormal 50-g, 1-hour glucose challenge test, 306 were diagnosed with GDM and 496 did not have GDM (false-positive group). In the GDM group, 218 women (71.2%) had adverse outcomes. In contrast, 240 women (48.4%) in the false-positive group had adverse outcomes. Women with adverse outcomes had a significantly higher body mass index (BMI) at entry (P = 0.03) and fasting blood glucose (FBG) (P = 0.03). Our logistic regression model derived from 2 variables, BMI at entry and FBG, predicted GDM adverse outcome with an area under the curve of 0.642, accuracy of 61.3%, sensitivity of 57.2%, and specificity of 66.9% compared with the conventional 2-step method with an area under the curve of 0.610, accuracy of 59.1%, sensitivity of 47.6%, and specificity of 74.4%. Our model performed better in predicting GDM adverse outcomes than the conventional 2-step method using only BMI at entry and FBG. Moreover, our model represents a practical, inexpensive, efficient, reproducible, easy, and patient- and clinician-friendly approach. PMID:26735528

  14. The postoperative Model for End stage Liver Disease score as a predictor of short-term outcome after transplantation of extended criteria donor livers.

    PubMed

    Benko, Tamas; Gallinat, Anja; Minor, Thomas; Saner, Fuat H; Sotiropoulos, Georgios C; Paul, Andreas; Hoyer, Dieter P

    2017-06-01

    Recently, the postoperative Model for End stage Liver Disease score (POPMELD) was suggested as a definition of postoperative graft dysfunction and a predictor of outcome after liver transplantation (LT). The aim of the present study was to validate this concept in the context of extended criteria donor (ECD) organs. Single-center prospectively collected data (OPAL study/01/11-12/13) of 116 ECD LTs were utilized. For each recipient, the Model for End stage Liver Disease (MELD) score was calculated for 7 postoperative days (PODs). The ability of international normalized ratio, bilirubin, aspartate aminotransferase, Donor Risk Index, a recent definition of early allograft dysfunction, and the POPMELD was compared to predict 90-day graft loss. Predictive abilities were compared by receiver operating characteristic curves, sensitivity and specificity, and positive and negative predictive values. The median Donor Risk Index was 1.8. In all, 60.3% of recipients were men [median age of 54 (23-68) years]. The median POD1-7 peak-aspartate aminotransferase value was 1052 (194-17 577) U/l. The rate of early allograft dysfunction was 22.4%. The 90-day graft survival was 89.7%. Out of possible predictors of the 90-day graft loss MELD on POD5 was the best predictor of outcome (area under the curve=0.84). A MELD score of 16 or more on POD5 predicted the 90-day graft loss with a specificity of 80.8%, a sensitivity of 81.8%, and a positive and negative predictive value of 31 and 97.7%. A MELD score of 16 or more on POD5 is an excellent predictor of outcome in ECD donor LT. Routine evaluation of POPMELD scores might support clinical decision-making and should be reported routinely in clinical trials.

  15. Diagnostic value of sTREM-1 in bronchoalveolar lavage fluid in ICU patients with bacterial lung infections: a bivariate meta-analysis.

    PubMed

    Shi, Jia-Xin; Li, Jia-Shu; Hu, Rong; Li, Chun-Hua; Wen, Yan; Zheng, Hong; Zhang, Feng; Li, Qin

    2013-01-01

    The serum soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) is a useful biomarker in differentiating bacterial infections from others. However, the diagnostic value of sTREM-1 in bronchoalveolar lavage fluid (BALF) in lung infections has not been well established. We performed a meta-analysis to assess the accuracy of sTREM-1 in BALF for diagnosis of bacterial lung infections in intensive care unit (ICU) patients. We searched PUBMED, EMBASE and Web of Knowledge (from January 1966 to October 2012) databases for relevant studies that reported diagnostic accuracy data of BALF sTREM-1 in the diagnosis of bacterial lung infections in ICU patients. Pooled sensitivity, specificity, and positive and negative likelihood ratios were calculated by a bivariate regression analysis. Measures of accuracy and Q point value (Q*) were calculated using summary receiver operating characteristic (SROC) curve. The potential between-studies heterogeneity was explored by subgroup analysis. Nine studies were included in the present meta-analysis. Overall, the prevalence was 50.6%; the sensitivity was 0.87 (95% confidence interval (CI), 0.72-0.95); the specificity was 0.79 (95% CI, 0.56-0.92); the positive likelihood ratio (PLR) was 4.18 (95% CI, 1.78-9.86); the negative likelihood ratio (NLR) was 0.16 (95% CI, 0.07-0.36), and the diagnostic odds ratio (DOR) was 25.60 (95% CI, 7.28-89.93). The area under the SROC curve was 0.91 (95% CI, 0.88-0.93), with a Q* of 0.83. Subgroup analysis showed that the assay method and cutoff value influenced the diagnostic accuracy of sTREM-1. BALF sTREM-1 is a useful biomarker of bacterial lung infections in ICU patients. Further studies are needed to confirm the optimized cutoff value.

  16. Assessment of glenohumeral subluxation in poststroke hemiplegia: comparison between ultrasound and fingerbreadth palpation methods.

    PubMed

    Kumar, Praveen; Mardon, Marianne; Bradley, Michael; Gray, Selena; Swinkels, Annette

    2014-11-01

    Glenohumeral subluxation (GHS) is a common poststroke complication. Treatment of GHS is hampered by the lack of objective, real-time clinical measurements. The aims of this study were: (1) to compare an ultrasound method of GHS measurement with the fingerbreadth palpation method using a receiver operating characteristic curve (ROC) and (2) to report the sensitivity and specificity of this method. A prospective study was conducted. The study was conducted in local hospitals and day centers in the southwest of England. One hundred five patients who had one-sided weakness following a first-time stroke (51 men, 54 women; mean age=71 years, SD=11) and who gave informed consent were enrolled in the study. Ultrasound measurements of acromion-greater tuberosity (AGT) distance were used for the assessment of GHS. Measurements were undertaken on both shoulders by a research physical therapist trained in shoulder ultrasound with the patient seated in a standardized position. Fingerbreadth palpation assessment of GHS was undertaken by a clinical physical therapist based at the hospital, who also visited the day centers. The area under the ROC curve was 0.73 (95% confidence interval [95% CI]=0.63, 0.83), suggesting that the ultrasound method has good agreement compared with the fingerbreadth palpation method. A cutoff point of ≥0.2 cm AGT measurement difference between affected and unaffected shoulders generated a sensitivity of 68% (95% CI=51%, 75%), a specificity of 62% (95% CI=47%, 80%), a positive likelihood ratio of 1.79 (95% CI=1.1, 2.9), and a negative likelihood ratio of 0.55 (95% CI=0.4, 0.8). Clinical therapists involved in the routine care of patients conducted the fingerbreadth palpation method. It is likely that they were aware of the patients' subluxation status. The ultrasound method can detect minor asymmetry (≤0.5 cm) and has the potential advantage over the fingerbreadth palpation method of identifying patients with minor subluxation. © 2014 American Physical Therapy Association.

  17. Rapid on-site evaluation with the Hemacolor rapid staining method of medical thoracoscopy biopsy specimens for the management of pleural disease.

    PubMed

    Porfyridis, Ilias; Georgiadis, Georgios; Michael, Michalis; Frangopoulos, Frangiskos; Vogazianos, Paris; Papadopoulos, Alexis; Kara, Panayiota; Charalampous, Charis; Georgiou, Andreas

    2016-08-01

    Medical thoracoscopy (MT) is useful for the management of pleural disease. Rapid on-site evaluation (ROSE) of transbronchial needle aspirates proved to be useful during bronchoscopy. We aimed to evaluate the diagnostic performance of ROSE of MT biopsy specimens and thoracoscopists' impression of the macroscopic appearance and assess the intermodality agreement between ROSE and final histopathologic diagnosis. Sixty two patients with exudative pleural effusions further investigated with MT were enrolled. MT was performed under local anaesthesia and conscious sedation, using the rigid pleuroscope. ROSE with the Hemacolor rapid staining method of the biopsy specimens was performed. Thoracoscopists' impression of the macroscopic appearance was recorded. The final diagnosis was established following histopathological examination. Thoracoscopic pleural biopsies were diagnosed in 61 patients (98.4%). Group A (n = 25) consisted of patients with malignancy and group B (n = 37) with benign disorders. Area under the curve of ROSE for the diagnosis of malignancy was 0.86 (95% CI: 0.76-0.96, P < 0.001), with a sensitivity of 79.17%, specificity of 94.59%, diagnostic accuracy of 88.5%, positive predictive value of 90.5% and negative predictive value of 87.5%. Intermodality agreement between ROSE and histopathology was good (κ ± SE = 0.615 ± 0.084, P < 0.001). Area under the curve of the thoracoscopists' impression of macroscopic appearance was 0.72 (95% CI: 0.58-0.85, P = 0.001), with a sensitivity of 100%, specificity of 44.7%, positive predictive value of 53.33% and negative predictive value of 100%. Rapid on-site evaluation during MT was found to have high accuracy for predicting malignancy. ROSE can provide the thoracoscopist with an on-site preliminary diagnosis, especially in cases with inconclusive macroscopic appearance. © 2016 Asian Pacific Society of Respirology.

  18. Development of a Screening Tool for Predicting Adverse Outcomes of Gestational Diabetes Mellitus: A Retrospective Cohort Study.

    PubMed

    Park, Jee Soo; Kim, Deok Won; Kwon, Ja-Young; Park, Yong Won; Kim, Young Han; Cho, Hee Young

    2016-01-01

    Gestational diabetes mellitus (GDM) is a common disease in pregnancy causing maternal and fetal complications. To prevent these adverse outcomes, optimal screening and diagnostic criteria must be adequate, timely, and efficient. This study suggests a novel approach that is practical, efficient, and patient- and clinician-friendly in predicting adverse outcomes of GDM. The authors conducted a retrospective cohort study via medical record review of patients admitted between March 2001 and April 2013 at the Severance Hospital, Seoul, South Korea. Patients diagnosed by a conventional 2-step method were evaluated according to the presence of adverse outcomes (neonatal hypoglycemia, hyperbilirubinemia, and hyperinsulinemia; admission to the neonatal intensive care unit; large for gestational age; gestational insulin therapy; and gestational hypertension). Of 802 women who had an abnormal 50-g, 1-hour glucose challenge test, 306 were diagnosed with GDM and 496 did not have GDM (false-positive group). In the GDM group, 218 women (71.2%) had adverse outcomes. In contrast, 240 women (48.4%) in the false-positive group had adverse outcomes. Women with adverse outcomes had a significantly higher body mass index (BMI) at entry (P = 0.03) and fasting blood glucose (FBG) (P = 0.03). Our logistic regression model derived from 2 variables, BMI at entry and FBG, predicted GDM adverse outcome with an area under the curve of 0.642, accuracy of 61.3%, sensitivity of 57.2%, and specificity of 66.9% compared with the conventional 2-step method with an area under the curve of 0.610, accuracy of 59.1%, sensitivity of 47.6%, and specificity of 74.4%. Our model performed better in predicting GDM adverse outcomes than the conventional 2-step method using only BMI at entry and FBG. Moreover, our model represents a practical, inexpensive, efficient, reproducible, easy, and patient- and clinician-friendly approach.

  19. ACCURACY OF PLASMA FREE METANEPHRINES IN THE DIAGNOSIS OF PHEOCHROMOCYTOMA AND PARAGANGLIOMA: A SYSTEMATIC REVIEW AND META-ANALYSIS.

    PubMed

    Chen, Yan; Xiao, Huangmeng; Zhou, Xieda; Huang, Xiaoyu; Li, Yanbing; Xiao, Haipeng; Cao, Xiaopei

    2017-10-01

    Various studies have validated plasma free metanephrines (MNs) as biomarkers for pheochromocytoma and paraganglioma (PPGL). This meta-analysis aimed to estimate the overall diagnostic accuracy of this biochemical test for PPGL. We searched the PubMed, the Cochrane Library, Web of Science, Embase, Scopus, OvidSP, and ProQuest Dissertations & Theses databases from January 1, 1995 to December 2, 2016 and selected studies written in English that assessed plasma free MNs in the diagnosis of PPGL. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the quality of the included studies. We calculated pooled sensitivities, specificities, positive and negative likelihood ratios, diagnostic odds ratios (DORs) and areas under curve (AUCs) with their 95% confidence intervals (95% CIs). Heterogeneity was assessed by I 2 . To identify the source of heterogeneity, we evaluated the threshold effect and performed a meta-regression. Deeks' funnel plot was selected for investigating any potential publication bias. Although the combination of metanephrine (MN) and normetanephrine (NMN) carried lower specificity (0.94, 95% CI 0.90-0.97) than NMN (0.97, 95% CI 0.92-0.99), NMN was generally more accurate than individual tests, with the highest AUC (0.99, 95% CI 0.97-0.99), DOR (443.35, 95% CI 216.9-906.23), and pooled sensitivity (0.97, 95% CI 0.94-0.98) values. Threshold effect and meta-regression analyses showed that different cut-offs, blood sampling positions, study types and test methods contributed to heterogeneity. This meta-analysis suggested an effective value for combined plasma free MNs for the diagnosis of PPGL, but testing for MNs requires more standardization using tightly regulated studies. AUC = area under curve; CI = confidence interval; DOR = diagnostic odds ratio; EIA = enzyme immunoassay; LC-ECD = liquid chromatography-electrochemical detection; LC-MS/MS = liquid chromatography-tandem mass spectrometry; MN = metanephrine; NMN = normetaneprhine; PPGL = pheochromocytoma and paraganglioma; QUADAS-2 = Quality Assessment of Diagnostic Accuracy Studies 2.

  20. Activities-specific balance confidence scale for predicting future falls in Indian older adults.

    PubMed

    Moiz, Jamal Ali; Bansal, Vishal; Noohu, Majumi M; Gaur, Shailendra Nath; Hussain, Mohammad Ejaz; Anwer, Shahnawaz; Alghadir, Ahmad

    2017-01-01

    Activities-specific balance confidence (ABC) scale is a subjective measure of confidence in performing various ambulatory activities without falling or experiencing a sense of unsteadiness. This study aimed to examine the ability of the Hindi version of the ABC scale (ABC-H scale) to discriminate between fallers and non-fallers and to examine its predictive validity for prospective falls. This was a prospective cohort study. A total of 125 community-dwelling older adults (88 were men) completed the ABC-H scale. The occurrence of falls over the follow-up period of 12 months was recorded. Discriminative validity was analyzed by comparing the total ABC-H scale scores between the faller and non-faller groups. A receiver operating characteristic curve analysis and a logistic regression analysis were used to examine the predictive accuracy of the ABC-H scale. The mean ABC-H scale score of the faller group was significantly lower than that of the non-faller group (52.6±8.1 vs 73.1±12.2; P <0.001). The optimal cutoff value for distinguishing faller and non-faller adults was ≤58.13. The sensitivity, specificity, area under the curve, and positive and negative likelihood ratios of the cutoff score were 86.3%, 87.3%, 0.91 ( P <0.001), 6.84, and 0.16, respectively. The percentage test accuracy and false-positive and false-negative rates were 86.87%, 12.2%, and 13.6%, respectively. A dichotomized total ABC-H scale score of ≤58.13% (adjusted odds ratio =0.032, 95% confidence interval =0.004-0.25, P =0.001) was significantly related with future falls. The ABC-H scores were significantly and independently related with future falls in the community-dwelling Indian older adults. The ability of the ABC-H scale to predict future falls was adequate with high sensitivity and specificity values.

  1. Artificial neural network in predicting craniocervical junction injury: an alternative approach to trauma patients.

    PubMed

    Bektaş, Frat; Eken, Cenker; Soyuncu, Secgin; Kilicaslan, Isa; Cete, Yildiray

    2008-12-01

    The aim of this study is to determine the efficiency of artificial intelligence in detecting craniocervical junction injuries by using an artificial neural network (ANN) that may be applicable in future studies of different traumatic injuries. Major head trauma patients with Glasgow Coma Scale

  2. EUS elastography (strain ratio) and fractal-based quantitative analysis for the diagnosis of solid pancreatic lesions.

    PubMed

    Carrara, Silvia; Di Leo, Milena; Grizzi, Fabio; Correale, Loredana; Rahal, Daoud; Anderloni, Andrea; Auriemma, Francesco; Fugazza, Alessandro; Preatoni, Paoletta; Maselli, Roberta; Hassan, Cesare; Finati, Elena; Mangiavillano, Benedetto; Repici, Alessandro

    2018-06-01

    EUS elastography is useful in characterizing solid pancreatic lesions (SPLs), and fractal analysis-based technology has been used to evaluate geometric complexity in oncology. The aim of this study was to evaluate EUS elastography (strain ratio) and fractal analysis for the characterization of SPLs. Consecutive patients with SPLs were prospectively enrolled between December 2015 and February 2017. Elastographic evaluation included parenchymal strain ratio (pSR) and wall strain ratio (wSR) and was performed with a new compact US processor. Elastographic images were analyzed using a computer program to determine the 3-dimensional histogram fractal dimension. A composite cytology/histology/clinical reference standard was used to assess sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating curve. Overall, 102 SPLs from 100 patients were studied. At final diagnosis, 69 (68%) were malignant and 33 benign. At elastography, both pSR and wSR appeared to be significantly higher in malignant as compared with benign SPLs (pSR, 24.5 vs 6.4 [P < .001]; wSR, 56.6 vs 15.3 [P < .001]). When the best cut-off levels of pSR and wSR at 9.10 and 16.2, respectively, were used, sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating curve were 88.4%, 78.8%, 89.7%, 76.9%, and 86.7% and 91.3%, 69.7%, 86.5%, 80%, and 85.7%, respectively. Fractal analysis showed a significant statistical difference (P = .0087) between the mean surface fractal dimension of malignant lesions (D = 2.66 ± .01) versus neuroendocrine tumor (D = 2.73 ± .03) and a statistical difference for all 3 channels red, green, and blue (P < .0001). EUS elastography with pSR and fractal-based analysis are useful in characterizing SPLs. (Clinical trial registration number: NCT02855151.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. The Assessment of Estrogen Receptor Status and Its Intratumoral Heterogeneity in Patients With Breast Cancer by Using 18F-Fluoroestradiol PET/CT.

    PubMed

    Yang, Zhongyi; Sun, Yifei; Xu, Xiaoping; Zhang, Yongping; Zhang, Jianping; Xue, Jing; Wang, Mingwei; Yuan, Huiyu; Hu, Silong; Shi, Wei; Zhu, Beiling; Zhang, Yingjian

    2017-06-01

    The aim of this study was to investigate the clinical value of F-fluoroestradiol (F-FES) PET/CT in the assessment of the estrogen receptor (ER) and its intratumoral heterogeneity in breast cancer patients. Forty-six female patients (50 lesions) with histologically confirmed invasive breast cancer who underwent both F-FES and F-FDG PET/CT in our center were retrospectively included. All the patients enrolled were scheduled to undergo biopsy. The F-FES and FDG uptakes were compared with pathological features (tumor size, ER, progesterone receptor, human epidermal growth factor receptor 2, and Ki67%). The optimal threshold to discriminate ER-positive and ER-negative lesions was determined by receiver operating characteristic curve analysis. Furthermore, we observed the intratumoral heterogeneity by a heterogeneity index (SUVmax/SUVmean) and compared the results with the Chang-Gung Image Texture Analysis. There was good agreement between F-FES uptake and ER, progesterone receptor, and human epidermal growth factor receptor 2 expression (P < 0.001), and the use of SUVmean instead of SUVmax can provide a slightly better correlation. The optimal threshold for F-FES PET/CT to discriminate between ER-positive and ER-negative lesions, as determined by receiver operating characteristic curve analysis, was an SUVmax of 1.82 (sensitivity = 88.2% and specificity = 87.5%) and SUVmean of 1.21 (sensitivity = 85.3% and specificity = 93.7). Our simplified heterogeneity index-FES can easily observe ER heterogeneity. In addition, our results suggested that recurrent/metastatic patients and lesions located other than breast might have greater heterogeneity. F-FES PET/CT is a feasible, noninvasive method for assessing ER expression in breast cancer patients. Because intratumoral heterogeneity exists, F-FES PET/CT might better reflect the ER expression, especially in metastatic patients after treatment, thus assisting in making individualized treatment decisions.

  4. Psychobiological influences on maternal sensitivity in the context of adversity.

    PubMed

    Finegood, Eric D; Blair, Clancy; Granger, Douglas A; Hibel, Leah C; Mills-Koonce, Roger

    2016-07-01

    This study evaluated prospective longitudinal relations among an index of poverty-related cumulative risk, maternal salivary cortisol, child negative affect, and maternal sensitivity across the first 2 postpartum years. Participants included 1,180 biological mothers residing in rural and predominantly low-income communities in the United States. Multilevel growth curve analyses indicated that an index of cumulative risk was positively associated with maternal cortisol across the postpartum (study visits occurring at approximately 7, 15, and 24 months postpartum) over and above effects for African American ethnicity, time of day of saliva collection, age, parity status, having given birth to another child, contraceptive use, tobacco smoking, body mass index, and breastfeeding. Consistent with a psychobiological theory of mothering, maternal salivary cortisol was negatively associated with maternal sensitivity observed during parent-child interactions across the first 2 postpartum years over and above effects for poverty-related cumulative risk, child negative affect, as well as a large number of covariates associated with cortisol and maternal sensitivity. Child negative affect expressed during parent-child interactions was negatively associated with observed maternal sensitivity at late (24 months) but not early time points of observation (7 months) and cumulative risk was negatively associated with maternal sensitivity across the postpartum and this effect strengthened over time. Results advance our understanding of the dynamic, transactional, and psychobiological influences on parental caregiving behaviors across the first 2 postpartum years. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Identifying women who are afraid of giving birth: A comparison of the fear of birth scale with the WDEQ-A in a large Australian cohort.

    PubMed

    Haines, H M; Pallant, J F; Fenwick, J; Gamble, J; Creedy, D K; Toohill, J; Hildingsson, I

    2015-12-01

    The WDEQ-A is the most widely used measure of childbirth fear in pregnant women; however there is increasing discussion in the literature that simpler, more culturally transferrable tools may offer a better solution to identifying fearful women in clinical practice. To compare the two item Fear of Birth Scale (FOBS) with the 33 item WDEQ-A in a large cohort of Australian pregnant women. Self-report questionnaires during second trimester including Wijma Delivery Expectancy Questionnaire (WDEQ-A) and Fear of Birth Scale (FOBS). Correlation of FOBS and WDEQ-A was tested using Spearman's correlation coefficients. Receiver operating characteristic (ROC) curve assessed the sensitivity and specificity of possible cut-points on the FOBS against WDEQ-A cut-point of ≥85. Sensitivity, specificity, positive and negative predictive values were determined. Fearful and non-fearful women as classified by both instruments were compared for differences in demographic, psycho-social and obstetric characteristics. 1410 women participated. The correlation between the instruments was strong (Spearman's Rho = 0.66, p < 0.001). The area under the ROC was 0.89 indicating high sensitivity with a FOBS cut-point of 54. Sensitivity was 89%, specificity 79% and Youden index 0.68. Positive predictive value was 85% and negative predictive value 79%. Both instruments identified high fear as significantly associated with first time mothers, previous emergency caesarean and women with self-reported anxiety and/or depression. Additionally FOBS identified a significant association between fearful women and preference for caesarean. This study supports the use of the FOBS in clinical practice to identify childbirth fear in pregnant women. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  6. Influence of upper and lower body adipose tissue on insulin sensitivity in South Asian men.

    PubMed

    Balakrishnan, Preetha; Grundy, Scott M; Islam, Arsalla; Dunn, Fredrick; Vega, Gloria Lena

    2012-10-01

    South Asians have a high prevalence of insulin resistance, which predisposes to type 2 diabetes. In the current study, we examined whether insulin sensitivity in South Asian men and men of European descent (Europids) relates to truncal and lower body fat, number of adipocytes, and cell size distribution. Fifteen South Asian men and 15 Europid young men with comparable body mass indexes completed assessments of insulin sensitivity, body composition analysis by dual-energy x-ray absorptiometry, and measurement of adipocyte cellularity in the subcutaneous abdominal (truncal) and gluteal (lower body) adipose tissue. The South Asians and the Europids had similar total body fat and fat contents in truncal and lower body regions. Compared to the Europids, the South Asians had a greater insulin resistance shown by fasting insulin, area-under-the-curve for postprandial insulin, oral glucose insulin sensitivity, homeostatic model assessment of insulin resistance, β-cell index, and triglyceride-to-high-density lipoprotein ratio. The South Asians had similar number of adipocytes to the Europids, but the South Asians had significantly higher ratios of small-to-larger adipocytes. The South Asians further had a higher fraction of very large adipocytes. In both South Asians and Europids, truncal fat was positively associated with insulin resistance. In the South Asians but not in the Europids, lower body fat was associated with severity of insulin resistance. The results suggest first, a higher ratio of small-to-larger adipocytes in the South Asians consistent with a lesser lipid storage capacity of adipose tissue; and second, the positive association of lower body fat with insulin resistance in the South Asians implies that fat in their lower body worsens insulin resistance. This association was not observed in the Europids.

  7. Water-based thixotropic polymer gel electrolyte for dye-sensitized solar cells.

    PubMed

    Park, Se Jeong; Yoo, Kichoen; Kim, Jae-Yup; Kim, Jin Young; Lee, Doh-Kwon; Kim, Bongsoo; Kim, Honggon; Kim, Jong Hak; Cho, Jinhan; Ko, Min Jae

    2013-05-28

    For the practical application of dye-sensitized solar cells (DSSCs), it is important to replace the conventional organic solvents based electrolyte with environmentally friendly and stable ones, due to the toxicity and leakage problems. Here we report a noble water-based thixotropic polymer gel electrolyte containing xanthan gum, which satisfies both the environmentally friendliness and stability against leakage and water intrusion. For application in DSSCs, it was possible to infiltrate the prepared electrolyte into the mesoporous TiO2 electrode at the fluidic state, resulting in sufficient penetration. As a result, this electrolyte exhibited similar conversion efficiency (4.78% at 100 mW cm(-2)) and an enhanced long-term stability compared to a water-based liquid electrolyte. The effects of water on the photovoltaic properties were examined elaborately from the cyclic voltammetry curves and impedance spectra. Despite the positive shift in the conduction band potential of the TiO2 electrode, the open-circuit voltage was enhanced by addition of water in the electrolyte due to the greater positive shift in the I(-)/I3(-) redox potential. However, due to the dye desorption and decreased diffusion coefficient caused by the water content, the short-circuit photocurrent density was reduced. These results will provide great insight into the development of efficient and stable water-based electrolytes.

  8. Evaluation of the Pediatric Symptom Checklist as a screening tool for the identification of emotional and psychosocial problems

    PubMed Central

    Muzzolon, Sandra Regina B.; Cat, Mônica Nunes L.; dos Santos, Lúcia Helena C.

    2013-01-01

    OBJECTIVE To investigate the Brazilian version of Pediatric Symptom Checklist (PSC) as a screening tool to identify psychosocial and emotional problems in schoolchildren from six to 12 years old. METHODS Diagnostic test conducted in a public school of Curitiba, Paraná (Southern Brazil), to evaluate the PSC accuracy and consistency, considering the Child Behavior Checklist (CBCL) as the gold standard. Among 415 parents invited for the study, 145 responded to both PSC and CBCL. The results of the two instruments were compared. PSC and CBCL were considered positive if scores ≥28 and >70 respectively. RESULTS Among the 145 cases, 49 (33.8%) were positive for both PSC and CBCL. The ROC curve showed the PSC score of 21 as the best cutoff point for screening psychosocial and emotional problems, with a sensitivity of 96.8% and a specificity of 86.7%. Regarding the reference cutoff (score ≥28 points), the sensitivity was 64.5% and the specificity, 100.0%, similar to those found in the original version of the tool. CONCLUSIONS The Portuguese version of PSC was effective for early identification of emotional and/or psychosocial problems in a schoolchildren group and may be useful for pediatricians. PMID:24142319

  9. Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification.

    PubMed

    Jiang, Jue; Shang, Xu; Wang, Hua; Xu, Yong-Bo; Gao, Ya; Zhou, Qi

    2015-03-01

    The aim of this study was to investigate the diagnostic values of conventional ultrasound and contrast-enhanced ultrasound (CEUS) in benign and malignant thyroid nodules with calcification. Conventional ultrasound and CEUS were performed in 122 patients with thyroid nodules with calcification. The thyroid nodules were characterized as benign or malignant by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of the two imaging methods were determined. The area under the receiver operating characteristics curve (AUC) was used to assess the diagnostic values of the two imaging methods. In 122 cases of thyroid nodules with calcification, 73 benign nodules and 49 malignant nodules were verified by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of conventional ultrasound were 50%, 77%, 59%, 69%, and 66%, respectively, and those of CEUS were 90%, 92%, 88%, 93%, and 91%, respectively. There were significant differences between the two imaging methods. AUCs of conventional ultrasound and CEUS were 0.628 ± 0.052 and 0.908 ± 0.031, suggesting low and high diagnostic values, respectively. CEUS has high diagnostic values, being significantly greater than those of conventional ultrasound, in differential diagnosis of benign and malignant thyroid nodules with calcification. Copyright © 2014. Published by Elsevier Taiwan.

  10. SenseWearMini and Actigraph GT3X Accelerometer Classification of Observed Sedentary and Light-Intensity Physical Activities in a Laboratory Setting.

    PubMed

    Feehan, Lynne M; Goldsmith, Charles H; Leung, April Y F; Li, Linda C

    Purpose: To compare the ability of SenseWear Mini (SWm) and Actigraph GT3X (AG 3 ) accelerometers to differentiate between healthy adults' observed sedentary and light activities in a laboratory setting. Methods: The 22 participants (15 women, 7 men), ages 19 to 72 years, wore SWm and AG 3 monitors and performed five sedentary and four light activities for 5 minutes each while observed in a laboratory setting. Performance was examined through comparisons of accuracy, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Correct identification of both types of activities was examined using area under the receiver operating characteristic curve (AUC). Results: Both monitors demonstrated excellent ability to identify sedentary activities (sensitivity>0.89). The SWm monitor was better at identifying light activities (specificity 0.61-0.71) than the AG 3 monitor (specificity 0.27-0.47) and thus also showed a greater ability to correctly identify both sedentary and light activities (SWm AUC 0.84; AG 3 AUC 0.62-0.73). Conclusions: SWm may be a more suitable monitor for detecting time spent in sedentary and light-intensity activities. This finding has clinical and research relevance for evaluation of time spent in lower intensity physical activities by sedentary adults.

  11. Computationally robust and noise resistant numerical detector for the detection of atmospheric infrasound.

    PubMed

    Lee, Dong-Chang; Olson, John V; Szuberla, Curt A L

    2013-07-01

    This work reports on a performance study of two numerical detectors that are particularly useful for infrasound arrays operating under windy conditions. The sum of squares of variance ratios (SSVR1)-proposed for detecting signals with frequency ranging from 1 to 10 Hz-is computed by taking the ratio of the squared sum of eigenvalues to the square of largest eigenvalue of the covariance matrix of the power spectrum. For signals with lower frequency between 0.015 and 0.1 Hz, SSVR2 is developed to reduce the detector's sensitivity to noise. The detectors' performances are graphically compared against the current method, the mean of cross correlation maxima (MCCM), using the receiver operating characteristics curves and three types of atmospheric infrasound, corrupted by Gaussian and Pink noise. The MCCM and SSVR2 detectors were also used to detect microbaroms from the 24 h-long infrasound data. It was found that the two detectors outperform the MCCM detector in both sensitivity and computational efficiency. For mine blasts corrupted by Pink noise (signal-to-noise ratio = -7 dB), the MCCM and SSVR1 detectors yield 62 and 88 % true positives when accepting 20% false positives. For an eight-sensor array, the speed gain is approximately eleven-fold for a 50 s long signal.

  12. International transferability of accident modification functions for horizontal curves.

    PubMed

    Elvik, Rune

    2013-10-01

    Studies of the relationship between characteristics of horizontal curves and accident rate have been reported in several countries. The characteristic most often studied is the radius of a horizontal curve. Functions describing the relationship between the radius of horizontal curves and accident rate have been developed in Australia, Canada, Denmark, Germany, Great Britain, New Zealand, Norway, Portugal, Sweden, and the United States. Other characteristics of horizontal curves that have been studied include deflection angle, curve length, the presence of transition curves, super-elevation in curves and distance to adjacent curves. This paper assesses the international transferability of mathematical functions (accident modification functions) that have been developed to relate the radius of horizontal curves to their accident rate. The main research problem is whether these functions are similar, which enhances international transferability, or dissimilar, which reduces international transferability. Accident modification functions for horizontal curve radius developed in the countries listed above are synthesised. The sensitivity of the functions to other characteristics of curves than radius is examined. Accident modification functions developed in different countries have important similarities. The functions diverge with respect to accident rate in the sharpest curves. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Evaluating the Correlation between Anteroposterior and Mediolateral Compensatory Curves and their Influence on Dentoskeletal Morphology-An In vitro CBCT Study.

    PubMed

    Babu, K Suresh; Kumar, A Nanda; Kommi, Pradeep Babu; Krishnan, P Hari; Kumar, M Senthil; Sabapathy, R Senkutvan; Kumar, V Vijay

    2017-08-01

    To date, many orthodontist corrects malocclusion based on patients aesthetic concern and fails to correct the compensatory curves. This scenario is due to less insight on understanding relationship of compensatory curves and its correlation in treatment prognosis. The purpose of this study was to evaluate the correlation between the curve of Spee, curve of Monson and curve of Wilson, their influence on dentoskeletal morphology and their contribution to occlusal stability. This study included 104 non-orthodontic models. The study casts were subdivided into two groups, Group-I consist 52 non- orthodontic models with Class-I molar relationship and Group-II consist of 52 non- orthodontic models with Class-II molar relationship. Curve of Spee was measured with digital vernier caliper, curve of Monson estimated using specially made sphere (7″inch, 8″ inch and 9″inch) and curve of Wilson was evaluated using Cone Beam Computed Technology (CBCT). Mean value for curve of Spee obtained for Group I and Group II is 1.844 mm and 3.188 mm. For curve of Monson, the mean value obtained for Group I and Group-II is 7.65 inches and 7.40 inches. The mean degree obtained for the curve of Wilson for Group I and Group-II is 12.05 and 16.49. The result showed positive correlation between curve of Spee and curve of Wilson and no correlation between curve of Monson and curve of Wilson and no correlation between curve of Spee and curve of Monson. The Pearson correlation coefficient analysis from the study confirmed these results. The results showed positive correlation between curve of spee and curve of Wilson. The data found in this study can be applied clinically for Class I and Class II malocclusion patients on diagnosis and treatment planning.

  14. Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bojechko, C.; Ford, E. C., E-mail: eford@uw.edu

    Purpose: To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. Methods: Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using the treatment planning system (TPS), four different types of variability were modeled: overall dose scaling, shifting the positions of the multileaf collimator (MLC) leaves, shifting of the patient position, and changes in the patient body contour. The gamma passmore » rate was calculated for the modified and unmodified plans and used to construct a receiver operator characteristic (ROC) curve to assess the detectability of the different parameter variations. The detectability is given by the area under the ROC curve (AUC). The TPS was also used to calculate the impact of the variations on the target dose–volume histogram. Results: Nine intensity modulation radiation therapy plans were measured for four different anatomical sites consisting of 70 separate fields. Results show that in vivo EPID dosimetry was most sensitive to variations in the machine output, AUC = 0.70 − 0.94, changes in patient body habitus, AUC = 0.67 − 0.88, and systematic shifts in the MLC bank positions, AUC = 0.59 − 0.82. These deviations are expected to have a relatively small clinical impact [planning target volume (PTV) D{sub 99} change <7%]. Larger variations have even higher detectability. Displacements in the patient’s position and random variations in MLC leaf positions were not readily detectable, AUC < 0.64. The D{sub 99} of the PTV changed by up to 57% for the patient position shifts considered here. Conclusions: In vivo EPID dosimetry is able to detect relatively small variations in overall dose, systematic shifts of the MLC’s, and changes in the patient habitus. Shifts in the patient’s position which can introduce large changes in the target dose coverage were not readily detected.« less

  15. Usefulness of Cellular Analysis of Bronchoalveolar Lavage Fluid for Predicting the Etiology of Pneumonia in Critically Ill Patients

    PubMed Central

    Hong, Hyo-Lim; Kim, Sung-Han; Huh, Jin Won; Sung, Heungsup; Lee, Sang-Oh; Kim, Mi-Na; Jeong, Jin-Yong; Lim, Chae-Man; Kim, Yang Soo; Woo, Jun Hee; Koh, Younsuck

    2014-01-01

    Background The usefulness of bronchoalveolar lavage (BAL) fluid cellular analysis in pneumonia has not been adequately evaluated. This study investigated the ability of cellular analysis of BAL fluid to differentially diagnose bacterial pneumonia from viral pneumonia in adult patients who are admitted to intensive care unit. Methods BAL fluid cellular analysis was evaluated in 47 adult patients who underwent bronchoscopic BAL following less than 24 hours of antimicrobial agent exposure. The abilities of BAL fluid total white blood cell (WBC) counts and differential cell counts to differentiate between bacterial and viral pneumonia were evaluated using receiver operating characteristic (ROC) curve analysis. Results Bacterial pneumonia (n = 24) and viral pneumonia (n = 23) were frequently associated with neutrophilic pleocytosis in BAL fluid. BAL fluid median total WBC count (2,815/µL vs. 300/µL, P<0.001) and percentage of neutrophils (80.5% vs. 54.0%, P = 0.02) were significantly higher in the bacterial pneumonia group than in the viral pneumonia group. In ROC curve analysis, BAL fluid total WBC count showed the best discrimination, with an area under the curve of 0.855 (95% CI, 0.750–0.960). BAL fluid total WBC count ≥510/µL had a sensitivity of 83.3%, specificity of 78.3%, positive likelihood ratio (PLR) of 3.83, and negative likelihood ratio (NLR) of 0.21. When analyzed in combination with serum procalcitonin or C-reactive protein, sensitivity was 95.8%, specificity was 95.7%, PLR was 8.63, and NLR was 0.07. BAL fluid total WBC count ≥510/µL was an independent predictor of bacterial pneumonia with an adjusted odds ratio of 13.5 in multiple logistic regression analysis. Conclusions Cellular analysis of BAL fluid can aid early differential diagnosis of bacterial pneumonia from viral pneumonia in critically ill patients. PMID:24824328

  16. Improving Beamline X-ray Optics by Analyzing the Damage to Crystallographic Structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zientek, John; Maj, Jozef; Navrotski, Gary

    2015-01-02

    The mission of the X-ray Characterization Laboratory in the X-ray Science Division (XSD) at the Advanced Photon Source (APS) is to support both the users and the Optics Fabrication Facility that produces high performance optics for synchrotron X-ray beamlines. The Topography Test Unit (TTU) in the X-ray Lab has been successfully used to characterize diffracting crystals and test monochromators by quantifying residual surface stresses. This topographic method has also been adapted for testing standard X-ray mirrors, characterizing concave crystal optics and in principle, can be used to visualize residual stresses on any optic made from single crystalline material. The TTUmore » has been instrumental in quantitatively determining crystal mounting stresses which are mechanically induced by positioning, holding, and cooling fixtures. It is this quantitative aspect that makes topography so useful since the requirements and responses for crystal optics and X-ray mirrors are quite different. In the case of monochromator crystals, even small residual or induced stresses, on the order of tens of kPa, can cause detrimental distortions to the perfect crystal rocking curves. Mirrors, on the other hand, are much less sensitive to induced stresses where stresses that are an order of magnitude greater can be tolerated. This is due to the fact that the surface rather than the lattice-spacing determines a mirror’s performance. For the highly sensitive crystal optics, it is essential to measure the in-situ rocking curves using topographs as mounting fixtures are adjusted. In this way, high heat-load monochromator crystals can be successfully mounted with minimum stress. Topographical analysis has been shown to be a highly effective method to visualize and quantify the distribution of stresses, to help identify methods that mitigate stresses, and most notably to improve diffractive crystal optic rocking curves.« less

  17. Accuracy of the Medication Adherence Report Scale (MARS-5) as a quantitative measure of adherence to inhalation medication in patients with COPD.

    PubMed

    Tommelein, Eline; Mehuys, Els; Van Tongelen, Inge; Brusselle, Guy; Boussery, Koen

    2014-05-01

    Self-report is considered most suitable to measure medication adherence in routine clinical practice. However, accuracy of self-report as a quantitative measure of adherence is not well documented. To assess the accuracy of a self-report measure of adherence (Medication Adherence Report Scale [MARS-5]) for identifying nonadherent users of inhalation medication among patients with chronic obstructive pulmonary disease (COPD), compared with medication refill adherence (MRA) as reference. We used baseline data from the Pharmaceutical Care for Patients with COPD (PHARMACOP)-trial (n = 734). Patients with incomplete MARS-5 and/or incomplete pharmacy refill records were excluded (n = 121). Internal consistency of MARS-5 (Crohnbach α) and Spearman rank correlation (ρ) with MRA were calculated. Different thresholds for nonadherence were used to calculate sensitivity, specificity, and positive predictive value (PPV), compared with dichotomized MRA (MRA ≥80% = adherent). A receiver operating characteristic (ROC) curve was plotted to determine the goodness of test. 613 patients were included in the analysis. The mean adherence score by MARS-5 (range = 5-25) was 23.5 (SD = 2.6); mean adherence by MRA was 83.4% (SD = 23.8%). Internal consistency of MARS-5 was high (α = 0.77). Continuous MARS-5 scores correlated poorly with continuous MRA scores (ρ = 0.10; P = 0.011). When lowering the nonadherence threshold stepwise from 25 to 20, MARS-5 did not reach sufficient sensitivity (53% to 13%), specificity (57% to 94%), and PPV (42% to 57%) to detect nonadherers compared with dichotomized MRA. ROC curve plotting resulted in an area under the curve value of 0.56 (95% CI = 0.521-0.616; P = 0.005). Self-reported adherence measured by MARS-5 is inaccurate in identifying nonadherence to inhalation medication in patients with COPD.

  18. Identifying Aboriginal-specific AUDIT-C and AUDIT-3 cutoff scores for at-risk, high-risk, and likely dependent drinkers using measures of agreement with the 10-item Alcohol Use Disorders Identification Test.

    PubMed

    Calabria, Bianca; Clifford, Anton; Shakeshaft, Anthony P; Conigrave, Katherine M; Simpson, Lynette; Bliss, Donna; Allan, Julaine

    2014-09-01

    The Alcohol Use Disorders Identification Test (AUDIT) is a 10-item alcohol screener that has been recommended for use in Aboriginal primary health care settings. The time it takes respondents to complete AUDIT, however, has proven to be a barrier to its routine delivery. Two shorter versions, AUDIT-C and AUDIT-3, have been used as screening instruments in primary health care. This paper aims to identify the AUDIT-C and AUDIT-3 cutoff scores that most closely identify individuals classified as being at-risk drinkers, high-risk drinkers, or likely alcohol dependent by the 10-item AUDIT. Two cross-sectional surveys were conducted from June 2009 to May 2010 and from July 2010 to June 2011. Aboriginal Australian participants (N = 156) were recruited through an Aboriginal Community Controlled Health Service, and a community-based drug and alcohol treatment agency in rural New South Wales (NSW), and through community-based Aboriginal groups in Sydney NSW. Sensitivity, specificity, and positive and negative predictive values of each score on the AUDIT-C and AUDIT-3 were calculated, relative to cutoff scores on the 10-item AUDIT for at-risk, high-risk, and likely dependent drinkers. Receiver operating characteristic (ROC) curve analyses were conducted to measure the detection characteristics of AUDIT-C and AUDIT-3 for the three categories of risk. The areas under the receiver operating characteristic (AUROC) curves were high for drinkers classified as being at-risk, high-risk, and likely dependent. Recommended cutoff scores for Aboriginal Australians are as follows: at-risk drinkers AUDIT-C ≥ 5, AUDIT-3 ≥ 1; high-risk drinkers AUDIT-C ≥ 6, AUDIT-3 ≥ 2; and likely dependent drinkers AUDIT-C ≥ 9, AUDIT-3 ≥ 3. Adequate sensitivity and specificity were achieved for recommended cutoff scores. AUROC curves were above 0.90.

  19. [The Alvarado score validation in diagnosing acute appendicitis in children at Braga Hospital].

    PubMed

    Gonçalves, Jean Pierre; Cerqueira, Arnaldo; Martins, Sofia

    2011-12-01

    Acute appendicitis (AA) is the leading cause of emergency abdominal surgery in children. The diagnosis is essentially clinical, but some methodologies, such as Alvarado score (AS), have been developed in order to avoid non-therapeutic laparotomy (15-30%). AS ≥ 5 or 6 is compatible with AA and is an indication for the patient to remain on observations, if AS ≥ 7 a laparotomy procedure may be indicated. To validate the AS for the AA diagnosis of children admitted at Braga Hospital. A validation study of diagnostic method (AS) using the histological examination as a gold standard. The study population consisted of 192 children (4-17 years) with abdominal pain that underwent appendectomy in the last 20 months (December 2008 to July 2010). It was determined the values of sensitivity (S), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), likelihood ratio (LR) and the ROC curve for three different cut-off points (SA =5, 6 and 7). We found that as the cut-off point of AS decreases progressively the sensitivity and specificity increases and reduces the VPN and VPP. Assuming a cut-off value of 5, only 18 children would be false negatives, instead of the 67 children if the cut-off point was 7 points. The analysis of ROC curves demonstrated a greater area under the curve for a cut-off equal to or greater than 5 (AUC = 70%). We recommend using a cut-off value of 5 points, since only 18 children with AA were initially classified as appendicitis unlikely, this value would increase to 67 patients for the SA value of ≥ 7. The AS is a valuable tool in screening children with abdominal pain for the diagnosis of AA. Nonetheless the diagnosis and final decision must be based on clinical and systematic reassessment of patients.

  20. Urinary Squamous Epithelial Cells Do Not Accurately Predict Urine Culture Contamination, but May Predict Urinalysis Performance in Predicting Bacteriuria.

    PubMed

    Mohr, Nicholas M; Harland, Karisa K; Crabb, Victoria; Mutnick, Rachel; Baumgartner, David; Spinosi, Stephanie; Haarstad, Michael; Ahmed, Azeemuddin; Schweizer, Marin; Faine, Brett

    2016-03-01

    The presence of squamous epithelial cells (SECs) has been advocated to identify urinary contamination despite a paucity of evidence supporting this practice. We sought to determine the value of using quantitative SECs as a predictor of urinalysis contamination. Retrospective cross-sectional study of adults (≥18 years old) presenting to a tertiary academic medical center who had urinalysis with microscopy and urine culture performed. Patients with missing or implausible demographic data were excluded (2.5% of total sample). The primary analysis aimed to determine an SEC threshold that predicted urine culture contamination using receiver operating characteristics (ROC) curve analysis. The a priori secondary analysis explored how demographic variables (age, sex, body mass index) may modify the SEC test performance and whether SECs impacted traditional urinalysis indicators of bacteriuria. A total of 19,328 records were included. ROC curve analysis demonstrated that SEC count was a poor predictor of urine culture contamination (area under the ROC curve = 0.680, 95% confidence interval [CI] = 0.671 to 0.689). In secondary analysis, the positive likelihood ratio (LR+) of predicting bacteriuria via urinalysis among noncontaminated specimens was 4.98 (95% CI = 4.59 to 5.40) in the absence of SECs, but the LR+ fell to 2.35 (95% CI = 2.17 to 2.54) for samples with more than 8 SECs/low-powered field (lpf). In an independent validation cohort, urinalysis samples with fewer than 8 SECs/lpf predicted bacteriuria better (sensitivity = 75%, specificity = 84%) than samples with more than 8 SECs/lpf (sensitivity = 86%, specificity = 70%; diagnostic odds ratio = 17.5 [14.9 to 20.7] vs. 8.7 [7.3 to 10.5]). Squamous epithelial cells are a poor predictor of urine culture contamination, but may predict poor predictive performance of traditional urinalysis measures. © 2016 by the Society for Academic Emergency Medicine.

  1. Raman spectroscopy based screening of IgG positive and negative sera for dengue virus infection

    NASA Astrophysics Data System (ADS)

    Bilal, M.; Saleem, M.; Bial, Maria; Khan, Saranjam; Ullah, Rahat; Ali, Hina; Ahmed, M.; Ikram, Masroor

    2017-11-01

    A quantitative analysis for the screening of immunoglobulin-G (IgG) positive human sera samples is presented for the dengue virus infection. The regression model was developed using 79 samples while 20 samples were used to test the performance of the model. The R-square (r 2) value of 0.91 was found through a leave-one-sample-out cross validation method, which shows the validity of this model. This model incorporates the molecular changes associated with IgG. Molecular analysis based on regression coefficients revealed that myristic acid, coenzyme-A, alanine, arabinose, arginine, vitamin C, carotene, fumarate, galactosamine, glutamate, lactic acid, stearic acid, tryptophan and vaccenic acid are positively correlated with IgG; while amide III, collagen, proteins, fatty acids, phospholipids and fucose are negatively correlated. For blindly tested samples, an excellent agreement has been found between the model predicted, and the clinical values of IgG. The parameters, which include sensitivity, specificity, accuracy and the area under the receiver operator characteristic curve, are found to be 100%, 83.3%, 95% and 0.99, respectively, which confirms the high quality of the model.

  2. Validation of Thwaites Index for diagnosing tuberculous meningitis in a Colombian population.

    PubMed

    Saavedra, Juan Sebastián; Urrego, Sebastián; Toro, María Eugenia; Uribe, Carlos Santiago; García, Jenny; Hernández, Olga; Arango, Juan Carlos; Pérez, Ángela Beatriz; Franco, Andrés; Vélez, Isabel Cristina; Del Corral, Helena

    2016-11-15

    To determine the diagnostic accuracy of Thwaites Index (TI) in a Colombian population to distinguish meningeal tuberculosis (MTB) from bacterial meningitis (BM) and from non-tuberculous meningitis. Exploratory analyses were conducted to assess the TI's validity for patients with human immunodeficiency virus (HIV) and children above six-years-old. The study included 527 patients, the TI was calculated and results compared with those of a reference standard established by expert neurologists. Sensitivity, specificity, area under the curve of receiver-operator characteristics (AUC-ROC) and likelihood ratios were calculated. The AUC-ROC to distinguish MTB from non-tuberculous meningitis was 0.72 (95% CI: 0.67-0.77) for HIV negative adults. AUC-ROC was 0.62 (95% CI: 0.50-0.74) for HIV positive adults and 0.83 (95% CI: 0.68-0.97) for children. For distinguishing MTB from BM the AUC-ROC was 0.78 (95% CI: 0.73-0.83); furthermore, the AUC-ROC was 0.57 (95% CI: 0.31-0.83) for HIV positive adults and 0.86 (95% CI: 0.73-0.99) for children. The TI was sensitive but not specific when used to distinguish MTB from BM in HIV negative adults. In HIV positive adults the index had low diagnostic accuracy. Moreover, the TI showed discrimination capability for children over 6years; however, research with larger samples is required in these. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Curved planar reformation and optimal path tracing (CROP) method for false positive reduction in computer-aided detection of pulmonary embolism in CTPA

    NASA Astrophysics Data System (ADS)

    Zhou, Chuan; Chan, Heang-Ping; Guo, Yanhui; Wei, Jun; Chughtai, Aamer; Hadjiiski, Lubomir M.; Sundaram, Baskaran; Patel, Smita; Kuriakose, Jean W.; Kazerooni, Ella A.

    2013-03-01

    The curved planar reformation (CPR) method re-samples the vascular structures along the vessel centerline to generate longitudinal cross-section views. The CPR technique has been commonly used in coronary CTA workstation to facilitate radiologists' visual assessment of coronary diseases, but has not yet been used for pulmonary vessel analysis in CTPA due to the complicated tree structures and the vast network of pulmonary vasculature. In this study, a new curved planar reformation and optimal path tracing (CROP) method was developed to facilitate feature extraction and false positive (FP) reduction and improve our PE detection system. PE candidates are first identified in the segmented pulmonary vessels at prescreening. Based on Dijkstra's algorithm, the optimal path (OP) is traced from the pulmonary trunk bifurcation point to each PE candidate. The traced vessel is then straightened and a reformatted volume is generated using CPR. Eleven new features that characterize the intensity, gradient, and topology are extracted from the PE candidate in the CPR volume and combined with the previously developed 9 features to form a new feature space for FP classification. With IRB approval, CTPA of 59 PE cases were retrospectively collected from our patient files (UM set) and 69 PE cases from the PIOPED II data set with access permission. 595 and 800 PEs were manually marked by experienced radiologists as reference standard for the UM and PIOPED set, respectively. At a test sensitivity of 80%, the average FP rate was improved from 18.9 to 11.9 FPs/case with the new method for the PIOPED set when the UM set was used for training. The FP rate was improved from 22.6 to 14.2 FPs/case for the UM set when the PIOPED set was used for training. The improvement in the free response receiver operating characteristic (FROC) curves was statistically significant (p<0.05) by JAFROC analysis, indicating that the new features extracted from the CROP method are useful for FP reduction.

  4. Essays in energy policy and planning modeling under uncertainty: Value of information, optimistic biases, and simulation of capacity markets

    NASA Astrophysics Data System (ADS)

    Hu, Ming-Che

    Optimization and simulation are popular operations research and systems analysis tools for energy policy modeling. This dissertation addresses three important questions concerning the use of these tools for energy market (and electricity market) modeling and planning under uncertainty. (1) What is the value of information and cost of disregarding different sources of uncertainty for the U.S. energy economy? (2) Could model-based calculations of the performance (social welfare) of competitive and oligopolistic market equilibria be optimistically biased due to uncertainties in objective function coefficients? (3) How do alternative sloped demand curves perform in the PJM capacity market under economic and weather uncertainty? How does curve adjustment and cost dynamics affect the capacity market outcomes? To address the first question, two-stage stochastic optimization is utilized in the U.S. national MARKAL energy model; then the value of information and cost of ignoring uncertainty are estimated for three uncertainties: carbon cap policy, load growth and natural gas prices. When an uncertainty is important, then explicitly considering those risks when making investments will result in better performance in expectation (positive expected cost of ignoring uncertainty). Furthermore, eliminating the uncertainty would improve strategies even further, meaning that improved forecasts of future conditions are valuable ( i.e., a positive expected value of information). Also, the value of policy coordination shows the difference between a strategy developed under the incorrect assumption of no carbon cap and a strategy correctly anticipating imposition of such a cap. For the second question, game theory models are formulated and the existence of optimistic (positive) biases in market equilibria (both competitive and oligopoly markets) are proved, in that calculated social welfare and producer profits will, in expectation, exceed the values that will actually be received. Theoretical analyses prove the general existence of this bias for both competitive and oligopolistic models when production costs and demand curves are uncertain. Also demonstrated is an optimistic bias for the net benefits of introducing a new technology into a market when the cost of the new technology is uncertainty. The optimistic biases are quantified for a model of the northwest European electricity market (including Belgium, France, Germany and the Netherlands). Demand uncertainty results in an optimistic bias of 150,000-220,000 [Euro]/hr of total surplus and natural gas price uncertainty yields a smaller bias of 8,000-10,000 [Euro]/hr for total surplus. Further, adding a new uncertain technology (biomass) to the set of possible generation methods almost doubles the optimistic bias (14,000-18,000 [Euro]/hr). The third question concerns ex ante evaluation of the Reliability Pricing Model (RPM)---the new PJM capacity market---launched in June 2007. A Monte Carlo simulation model is developed to simulate PJM capacity market and predict market performance, producer revenue, and consumer payments. An important input to RPM is a demand curve for capacity; several alternative demand curves are compared, and sensitivity analyses conducted of those conclusions. One conclusion is that the sloped demand curves are more robust because those demand curves gives higher reliability with lower consumer payments. In addition, the performance of the curves is evaluated for a more sophisticated market design in which the demand curve can be adjusted in response to previous market outcomes and where the capital costs may change unexpectedly. The simulation shows that curve adjustment increases system reliability with lower consumer payments. Also the effect of learning-by-doing, leading to lower plant capital costs, leads to higher average reserve margin and lower consumer payments. In contrast, a the sudden rise in capital costs causes a decrease in reliability and an increase in consumer payments.

  5. Using ROC Curves to Choose Minimally Important Change Thresholds when Sensitivity and Specificity Are Valued Equally: The Forgotten Lesson of Pythagoras. Theoretical Considerations and an Example Application of Change in Health Status

    PubMed Central

    Froud, Robert; Abel, Gary

    2014-01-01

    Background Receiver Operator Characteristic (ROC) curves are being used to identify Minimally Important Change (MIC) thresholds on scales that measure a change in health status. In quasi-continuous patient reported outcome measures, such as those that measure changes in chronic diseases with variable clinical trajectories, sensitivity and specificity are often valued equally. Notwithstanding methodologists agreeing that these should be valued equally, different approaches have been taken to estimating MIC thresholds using ROC curves. Aims and objectives We aimed to compare the different approaches used with a new approach, exploring the extent to which the methods choose different thresholds, and considering the effect of differences on conclusions in responder analyses. Methods Using graphical methods, hypothetical data, and data from a large randomised controlled trial of manual therapy for low back pain, we compared two existing approaches with a new approach that is based on the addition of the sums of squares of 1-sensitivity and 1-specificity. Results There can be divergence in the thresholds chosen by different estimators. The cut-point selected by different estimators is dependent on the relationship between the cut-points in ROC space and the different contours described by the estimators. In particular, asymmetry and the number of possible cut-points affects threshold selection. Conclusion Choice of MIC estimator is important. Different methods for choosing cut-points can lead to materially different MIC thresholds and thus affect results of responder analyses and trial conclusions. An estimator based on the smallest sum of squares of 1-sensitivity and 1-specificity is preferable when sensitivity and specificity are valued equally. Unlike other methods currently in use, the cut-point chosen by the sum of squares method always and efficiently chooses the cut-point closest to the top-left corner of ROC space, regardless of the shape of the ROC curve. PMID:25474472

  6. SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chvetsov, A

    2014-06-01

    Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method wheremore » the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S{sub 2}=0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S{sub 2}=0.7 and then approached zero as S{sub 2} is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S{sub 2} is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S{sub 2} are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation.« less

  7. Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C

    NASA Technical Reports Server (NTRS)

    Yukihara, E. G.; Whitley, V. H.; McKeever, S. W. S.; Akselrod, A. E.; Akselrod, M. S.

    2004-01-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al2O3:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F+ -centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al2O3:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed. c2004 Elsevier Ltd. All rights reserved.

  8. Performance of procalcitonin in diagnosing parapneumonic pleural effusions: A clinical study and meta-analysis.

    PubMed

    He, Chao; Wang, Bo; Li, Danni; Xu, Huan; Shen, Yongchun

    2017-08-01

    Parapneumonic pleural effusion (PPE) is a common complication of pneumonia. The accurate diagnosis of PPE remains a challenge. Recent studies suggest that procalcitonin (PCT) emerges as a potential biomarker for PPE. Our study aimed to determine the diagnostic value of PCT for PPE by a clinical study and summarize the overall diagnostic performance of PCT through a meta-analysis. Demographic and clinical data of the patients with PPE and controls were collected in our clinical study. The diagnostic performances of serum PCT (s-PCT) were analyzed via receiver operating characteristic (ROC) curve analysis, using area under the curve (AUC) as a measure of accuracy. Literature databases were systematically searched for the studies examining the accuracy of PCT for diagnosing PPE. Data on sensitivity, specificity, positive/negative likelihood ratio (PLR/NLR), and diagnostic odds ratio (DOR) were pooled. Summary ROC curves and AUC were used to evaluate overall test performance. In our clinical study, 47 patients with PPE and 101 controls were included. The s-PCT levels were significantly increased in the setting of PPE (5.44 ± 9.82 ng/mL) compared with malignant PE (0.15 ± 0.19 ng/mL), tuberculous PE (0.18 ± 0.16 ng/mL), and transudates (0.09 ± 0.03 ng/mL) (P < .001). Using a cutoff value of 0.195 ng/mL, the sensitivity and specificity of s-PCT in diagnosing PPE were 0.83 and 0.80, respectively, and AUC was 0.89. In addition, 11 studies were included in our meta-analysis. Summary performance estimates for s-PCT in diagnosing PPE were as follows: sensitivity, 0.78 (95% CI: 0.71-0.84); specificity, 0.74 (95% CI: 0.69-0.78); PLR, 3.46 (95% CI: 2.09-5.74); NLR, 0.27 (95% CI: 0.14-0.54); DOR, 12.37 (95% CI: 4.34-41.17); and AUC, 0.84. The corresponding estimates for p-PCT were as follows: sensitivity, 0.62 (95% CI: 0.57-0.67); specificity, 0.71 (95% CI: 0.68-0.75); PLR 2.31 (95% CI: 1.81-2.95); NLR, 0.47 (95% CI: 0.35-0.63); DOR, 5.48 (95% CI: 3.07-9.77); and AUC, 0.80. Both s-PCT and p-PCT might have modest performance in diagnosing PPE. However, more studies on a large scale should be performed to confirm our findings.

  9. Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams.

    PubMed

    Marinelli, Marco; Prestopino, G; Verona, C; Verona-Rinati, G; Ciocca, M; Mirandola, A; Mairani, A; Raffaele, L; Magro, G

    2015-04-01

    To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30-250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm(2) were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm(2) area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using fluka Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

  10. Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis

    PubMed Central

    Guo, Chuan-Guo; Ji, Rui; Li, Yan-Qing

    2015-01-01

    Background i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps. Objective Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps. Methods We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy. Results The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively. Conclusions Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%. PMID:25978459

  11. Study of constraints in using household NaCl salt for retrospective dosimetry

    NASA Astrophysics Data System (ADS)

    Elashmawy, M.

    2018-05-01

    Thermoluminescence (TL) characteristics of 5 different household NaCl salts and one analytical salt were determined to investigate the possible factors that affect the reliability of using household salt for retrospective dosimetry. Salts' TL sensitivities were found to be particle-size dependent and approached saturation at the largest size, whereas for salts that have the same particle size, the TL sensitivity depended on their origin. TL dependence on the particle size interprets significant variations in TL response reported in the literature for the same salt patch. The first TL readout indicated that all salts have similar glow curves with one distinctive peak. Typical second TL readout at two different doses showed a dramatic decrease in TL sensitivity associated with a significant change in the glow curve structure possessing two prominent peaks. Glow curve deconvolution (GCD) of the first TL readout for all salts yielded 6 individual glow peaks of first-order kinetics, whereas in GCD of second TL readouts, 5 individual glow peaks of second-order kinetics were obtained. Similarities in the glow curve structures of the first and second TL readouts suggest that additives such as KIO3 and MgCO3 have no effect on the TL process. Fading effect was evaluated for the salt of highest TL sensitivity, and it was found that the integral TL intensity decreased gradually and lost 40% of its initial value over 2 weeks, after which it remained constant. Results conclude that a household salt cannot be used for retrospective dosimetry without considering certain constraints such as the salt's origin and particle size. Furthermore, preparedness for radiological accidents and accurate dose reconstructions require that most of the commonly distributed household salt brands should be calibrated in advance and stored in a repository to be recalled in case of accidents.

  12. Diagnostic performance of a computer-assisted diagnosis system for bone scintigraphy of newly developed skeletal metastasis in prostate cancer patients: search for low-sensitivity subgroups.

    PubMed

    Koizumi, Mitsuru; Motegi, Kazuki; Koyama, Masamichi; Terauchi, Takashi; Yuasa, Takeshi; Yonese, Junji

    2017-08-01

    The computer-assisted diagnostic system for bone scintigraphy (BS) BONENAVI is used to evaluate skeletal metastasis. We investigated its diagnostic performance in prostate cancer patients with and without skeletal metastasis and searched for the problems. An artificial neural network (ANN) value was calculated in 226 prostate cancer patients (124 with skeletal metastasis and 101 without) using BS. Receiver operating characteristic curve analysis was performed and the sensitivity and specificity determined (cutoff ANN = 0.5). Patient's situation at the time of diagnosis of skeletal metastasis, computed tomography (CT) type, extent of disease (EOD), and BS uptake grade were analyzed. False-negative and false-positive results were recorded. BONENAVI showed 82% (102/124) of sensitivity and 83% (84/101) specificity for metastasis detection. There were no significant differences among CT types, although low EOD and faint BS uptake were associated with low ANN values and low sensitivity. Patients showed lower sensitivity during the follow-up period than staging work-up. False-negative lesions were often located in the pelvis or adjacent to it. They comprised not only solitary, faint BS lesions but also overlaying to urinary excretion. BONENAVI with BS has good sensitivity and specificity for detecting prostate cancer's osseous metastasis. Low EOD and faint BS uptake are associated with low sensitivity but not the CT type. Prostate cancer patients likely to have false-negative results during the follow-up period had a solitary lesion in the pelvis with faint BS uptake or lesions overlaying to urinary excretion.

  13. A new attraction-disseverance model for explaining landsliding in clay-rich tephras

    NASA Astrophysics Data System (ADS)

    Kluger, M. O.; Moon, V.; Kreiter, S.; Lowe, D.; Churchman, J.; Hepp, D. A.; Seibel, D.; Jorat, E.; Mörz, T.

    2016-12-01

    Altered tephras are highly susceptible to landsliding and account for fatalities and property damage every year. The clay mineral halloysite is often associated with landslide-prone layers within weathered tephra successions, especially in deposits with high sensitivity, which describes the post-failure strength loss. However, the precise role of halloysite on the development of sensitivity and thus sudden and unpredictable landsliding is unknown. Here we show that an abundance of halloysite, dominated by a distinctive ovate mushroom-cap-shaped (MCS) spherical morphology, governs the development of sensitivity, and hence proneness to landsliding, in weathered rhyolitic tephras in eastern North Island, New Zealand. We found that a highly sensitive layer, which was involved in a retrogressive landslide, has an extraordinarily high content of aggregated MCS spheres with imperfectly-closed exterior surfaces, i.e., the MCS spheres have substantial openings on one side. We suggest that short-range electrostatic and van der Waals' interactions enabled the MCS spheres to form interconnected aggregates by attraction between numerous paired silanol and aluminol layers with a weakly positive, or neutral, charge exposed in the openings and the negatively-charged convex silanol faces on the curved exterior surfaces of the spheres. However, if these weak attractions are overcome during slope failure, the prevailing repulsion between two exterior surfaces result in a low remolded shear strength, i.e., a high sensitivity, and thus a high propensity for flow-like landsliding. Our results indicate that this novel electrostatic attraction-disseverance model explains the high sensitivity and therefore contributes to a general understanding of the mechanisms of landsliding in sensitive altered tephras rich in spherical halloysite.

  14. Serial Position Curves in Free Recall

    ERIC Educational Resources Information Center

    Laming, Donald

    2010-01-01

    The scenario for free recall set out in Laming (2009) is developed to provide models for the serial position curves from 5 selected sets of data, for final free recall, and for multitrial free recall. The 5 sets of data reflect the effects of rate of presentation, length of list, delay of recall, and suppression of rehearsal. Each model…

  15. ROC analysis of diagnostic performance in liver scintigraphy.

    PubMed

    Fritz, S L; Preston, D F; Gallagher, J H

    1981-02-01

    Studies on the accuracy of liver scintigraphy for the detection of metastases were assembled from 38 sources in the medical literature. An ROC curve was fitted to the observed values of sensitivity and specificity using an algorithm developed by Ogilvie and Creelman. This ROC curve fitted the data better than average sensitivity and specificity values in each of four subsets of the data. For the subset dealing with Tc-99m sulfur colloid scintigraphy, performed for detection of suspected metastases and containing data on 2800 scans from 17 independent series, it was not possible to reject the hypothesis that interobserver variation was entirely due to the use of different decision thresholds by the reporting clinicians. Thus the ROC curve obtained is a reasonable baseline estimate of the performance potentially achievable in today's clinical setting. Comparison of new reports with these data is possible, but is limited by the small sample sizes in most reported series.

  16. Curvature facilitates prey fixation in predatory insect claws.

    PubMed

    Petie, Ronald; Muller, Mees

    2007-02-21

    Insects show a large variety in prey capture strategies, with a correspondingly large diversity in predatory adaptations. We studied a specific type of predatory claws, these can for example be found in praying mantis species. The claw is closeable over its entire length and the prey is fixed between the femur (upper arm) and the tibia (lower arm) of the insect leg. The morphology of these predatory claws is diverse. Some species have straight claws covered with spines, while other species have smooth, curved claws. We have studied the mechanics of this femur-tibia type of predatory insect claws, by making a physical model, eventually trying to explain why in some insect species the claws are curved instead of straight. The main results are (1) when comparing curved claws to straight claws, curvature leads to a strong reduction of forces driving the prey away from the pivoting point, thereby reducing the need for friction generating structures. (2) In the curved claw model a position exists where the resulting force on the prey is exactly zero. This is because the normal forces on the femur and tibia are opposed, and in line. At this position the prey is perfectly clamped and not driven out of the claw. This feature does not exist in straight claws. (3) In the curved claw, the prey cannot be placed at a position further than a certain maximum distance from the pivoting point. Near this maximum position, the resulting force on the prey reaches high values because moment arms are near zero. (4) Between the zero position and the maximum position the resulting force is directed toward the pivoting point, which stabilizes prey fixation.

  17. GPS/DR Error Estimation for Autonomous Vehicle Localization.

    PubMed

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-08-21

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level.

  18. GPS/DR Error Estimation for Autonomous Vehicle Localization

    PubMed Central

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-01-01

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level. PMID:26307997

  19. Predicting extracapsular involvement in prostate cancer through the tumor contact length and the apparent diffusion coefficient.

    PubMed

    Granja, M F; Pedraza, C M; Flórez, D C; Romero, J A; Palau, M A; Aguirre, D A

    To evaluate the diagnostic performance of the length of the tumor contact with the capsule (LTC) and the apparent diffusion coefficient (ADC) map in the prediction of microscopic extracapsular extension in patients with prostate cancer who are candidates for radical prostatectomy. We used receiver operating curves to retrospectively study the diagnostic performance of the ADC map and the LTC as predictors of microscopic extracapsular extension in 92 patients with prostate cancer and moderate to high risk who were examined between May 2011 and December 2013. The optimal cutoff for the ADC map was 0.87× 10 -3 mm 2 /s, which yielded an area under the ROC curve of 72% (95% CI: 57%-86%), corresponding to a sensitivity of 83% and a specificity of 61%. The optimal cutoff for the LTC was 17.5mm, which yielded an area under the ROC curve of 74% (95% CI: 61%-87%), corresponding to a sensitivity of 91% and a specificity of 57%. Combining the two criteria improved the diagnostic performance, yielding an area under the ROC curve of 77% (95% CI: 62%-92%), corresponding to a sensitivity of 77% and a specificity of 61%. We elaborated a logistic regression model, obtaining an area under the ROC curve of 82% (95% CI: 73%-93%). Using quantitative measures improves the diagnostic accuracy of multiparametric magnetic resonance imaging in the staging of prostate cancer. The values of the ADC and LTC were predictors of microscopic extracapsular extension, and the best results were obtained when both values were used in combination. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. The effect of CO2 on ventilation and breath-holding during exercise and while breathing through an added resistance.

    PubMed

    Clark, T J; Godfrey, S

    1969-05-01

    1. Ventilation was measured while subjects were made to rebreathe from a bag containing CO(2) and O(2) in order to expose them to a steadily rising CO(2) tension (P(CO2)). The object of the experiments was to determine the effect of a variety of stimuli upon the increase in ventilation and fall in breath-holding time which occurs in response to the rising P(CO2).2. Steady-state exercise at 200 kg.m/min resulted in a small fall in the slope of the ventilation-CO(2) response curve (S(V)) and a small, though not statistically significant, fall in the P(CO2) at which ventilation would be zero by extrapolation (B(V)). There was a marked fall in the slope of the breath-holding-CO(2) response curve (S(BH)) and an increase in the P(CO2) at which breath-holding time became zero by extrapolation (B(BH)).3. These results have been interpreted with the aid of a model of the control of breath-holding and it is suggested that there is no change in CO(2) sensitivity on exercise, either during rebreathing or breath-holding.4. An increase in the resistance to breathing caused a marked reduction in S(V) and B(V), but no change in the breath-holding-CO(2) response curve. These findings suggest that the flattening of the ventilation-CO(2) response curve is mechanical in origin and acute airway obstruction produces no change in CO(2) sensitivity.5. On the basis of these results, we suggest that more information about CO(2) sensitivity can be obtained by a combination of ventilation and breath-holding-CO(2) response curves.

Top