Sample records for custom crds-based trace

  1. Flask sample measurements for CO2, CH4 and CO using cavity ring-down spectrometry

    NASA Astrophysics Data System (ADS)

    Wang, J.-L.; Jacobson, G.; Rella, C. W.; Chang, C.-Y.; Liu, I.; Liu, W.-T.; Chew, C.; Ou-Yang, C.-F.; Liao, W.-C.; Chang, C.-C.

    2013-08-01

    In recent years, cavity ring-down spectrometry (CRDS) has been demonstrated to be a highly sensitive, stable and fast analytical technique for real-time in situ measurements of greenhouse gases. In this study, we propose the technique (which we call flask-CRDS) of analyzing whole air flask samples for CO2, CH4 and CO using a custom gas manifold designed to connect to a CRDS analyzer. Extremely stable measurements of these gases can be achieved over a large pressure range in the flask, from 175 to 760 Torr. The wide pressure range is conducive to flask sample measurement in three ways: (1) flask samples can be collected in low-pressure environments (e.g. high-altitude locations); (2) flask samples can be first analyzed for other trace gases with the remaining low-pressure sample for CRDS analysis of CO2, CH4 and CO; and (3) flask samples can be archived and re-analyzed for validation. The repeatability of this method (1σ of 0.07 ppm for CO2, 0.4 ppb for CH4, and 0.5 ppb for CO) was assessed by analyzing five canisters filled with the same air sample to a pressure of 200 Torr. An inter-comparison of the flask-CRDS data with in-situ CRDS measurements at a high-altitude mountain baseline station revealed excellent agreement, with differences of 0.10 ± 0.09 ppm (1σ) for CO2 and 0.9 ± 1.0 ppb for CH4. This study demonstrated that the flask-CRDS method was not only simple to build and operate but could also perform highly accurate and precise measurements of atmospheric CO2, CH4 and CO in flask samples.

  2. Continuous wave external-cavity quantum cascade laser-based high-resolution cavity ring-down spectrometer for ultrasensitive trace gas detection.

    PubMed

    De, Anulekha; Banik, Gourab Dutta; Maity, Abhijit; Pal, Mithun; Pradhan, Manik

    2016-05-01

    A high-resolution cavity ring-down spectroscopic (CRDS) system based on a continuous wave (cw) mode-hop-free (MHF) external-cavity quantum cascade laser (EC-QCL) operating at λ∼5.2  μm has been developed for ultrasensitive detection of nitric oxide (NO). We report the performance of the high-resolution EC-QCL based cw-CRDS instrument by measuring the rotationally resolved Λ-doublet e and f components of the P(7.5) line in the fundamental band of NO at 1850.169  cm-1 and 1850.179  cm-1. A noise-equivalent absorption coefficient of 1.01×10-9  cm-1  Hz-1/2 was achieved based on an empty cavity ring-down time of τ0=5.6  μs and standard deviation of 0.11% with averaging of six ring-down time determinations. The CRDS sensor demonstrates the advantages of measuring parts per billion NO concentrations in N2, as well as in human breath samples with ultrahigh sensitivity and specificity. The CRDS system could also be generalized to measure simultaneously many other trace molecular species within the broad tuning range of cw EC-QCL, as well as for studying the rotationally resolved hyperfine structures.

  3. Development of ball surface acoustic wave trace moisture analyzer using burst waveform undersampling circuit

    NASA Astrophysics Data System (ADS)

    Tsuji, Toshihiro; Oizumi, Toru; Fukushi, Hideyuki; Takeda, Nobuo; Akao, Shingo; Tsukahara, Yusuke; Yamanaka, Kazushi

    2018-05-01

    The measurement and control of trace moisture, where the water concentration is lower than 1 ppmv [-76.2 °C for the frost point (°CFP)], are essential for improving the yield rate of semiconductor devices and for ensuring their reliability. A ball surface acoustic wave (SAW) sensor with a sol-gel silica coating exhibited useful characteristics for a trace moisture analyzer (TMA) when the temperature drift of the delay time output was precisely compensated using two-frequency measurement (TFM), where the temperature-compensated relative delay time change (RDTC) was obtained by subtracting the RDTC at the fundamental frequency from that at the third harmonic frequency on an identical propagation path. However, the cost of the measurement circuit was a problem. In this study, a burst waveform undersampling (BUS) circuit based on the theory of undersampling measurement was developed as a practical means. The BUS circuit was useful for precise temperature compensation of the RDTC, and the ball SAW TMA was prototyped by calibrating the RDTC using a TMA based on cavity ring-down spectroscopy (CRDS), which is the most reliable method for trace moisture measurement. The ball SAW TMA outputted a similar concentration to that obtained by the CRDS TMA, and its response time at a set concentration in N2 with a flow rate of 1 l/min was about half that of the CRDS TMA, suggesting that moisture of -80 °CFP was measured within only 1 min. The detection limit at a signal-to-noise ratio of 3 was estimated to be 0.05 ppbv, comparable with that of the CRDS TMA. From these results, it was demonstrated that a practical ball SAW TMA can be realized using the developed BUS circuit.

  4. System for δ13C-CO2 and xCO2 analysis of discrete gas samples by cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Dickinson, Dane; Bodé, Samuel; Boeckx, Pascal

    2017-11-01

    A method was devised for analysing small discrete gas samples (50 mL syringe) by cavity ring-down spectroscopy (CRDS). Measurements were accomplished by inletting 50 mL syringed samples into an isotopic-CO2 CRDS analyser (Picarro G2131-i) between baseline readings of a reference air standard, which produced sharp peaks in the CRDS data feed. A custom software script was developed to manage the measurement process and aggregate sample data in real time. The method was successfully tested with CO2 mole fractions (xCO2) ranging from < 0.1 to > 20 000 ppm and δ13C-CO2 values from -100 up to +30 000 ‰ in comparison to VPDB (Vienna Pee Dee Belemnite). Throughput was typically 10 samples h-1, with 13 h-1 possible under ideal conditions. The measurement failure rate in routine use was ca. 1 %. Calibration to correct for memory effects was performed with gravimetric gas standards ranging from 0.05 to 2109 ppm xCO2 and δ13C-CO2 levels varying from -27.3 to +21 740 ‰. Repeatability tests demonstrated that method precision for 50 mL samples was ca. 0.05 % in xCO2 and 0.15 ‰ in δ13C-CO2 for CO2 compositions from 300 to 2000 ppm with natural abundance 13C. Long-term method consistency was tested over a 9-month period, with results showing no systematic measurement drift over time. Standardised analysis of discrete gas samples expands the scope of application for isotopic-CO2 CRDS and enhances its potential for replacing conventional isotope ratio measurement techniques. Our method involves minimal set-up costs and can be readily implemented in Picarro G2131-i and G2201-i analysers or tailored for use with other CRDS instruments and trace gases.

  5. An external-cavity quantum cascade laser operating near 5.2 µm combined with cavity ring-down spectroscopy for multi-component chemical sensing

    NASA Astrophysics Data System (ADS)

    Dutta Banik, Gourab; Maity, Abhijit; Som, Suman; Pal, Mithun; Pradhan, Manik

    2018-04-01

    We report on the performance of a widely tunable continuous wave mode-hop-free external-cavity quantum cascade laser operating at λ ~ 5.2 µm combined with cavity ring-down spectroscopy (CRDS) technique for high-resolution molecular spectroscopy. The CRDS system has been utilized for simultaneous and molecule-specific detection of several environmentally and bio-medically important trace molecular species such as nitric oxide, nitrous oxide, carbonyl sulphide and acetylene (C2H2) at ultra-low concentrations by probing numerous rotationally resolved ro-vibrational transitions in the mid-IR spectral region within a relatively small spectral range of ~0.035 cm-1. This continuous wave external-cavity quantum cascade laser-based multi-component CRDS sensor with high sensitivity and molecular specificity promises applications in environmental sensing as well as non-invasive medical diagnosis through human breath analysis.

  6. Cavity ring-down spectroscopy using an EC-QCL operating at 7.5 µm for direct monitoring of methane isotopes in air

    NASA Astrophysics Data System (ADS)

    Maity, Abhijit; Pal, Mithun; Dutta Banik, Gourab; Maithani, Sanchi; Pradhan, Manik

    2017-11-01

    A number of atmospheric pollutants and greenhouse gases have strong fundamental vibrational transitions within the spectral range of 7.5-8 µm, which marks the region as particularly important for trace gas sensing. Here, we report the development of a mid-infrared continuous-wave (cw) cavity ring-down spectroscopy (CRDS) technique coupled with an external-cavity (EC) mode-hop-free quantum cascade laser (QCL) operating at 7.5 µm. We validated the EC-QCL based high-resolution cw-CRDS system by measuring 12CH4 and 13CH4 isotopes of methane (CH4) which served as a benchmark molecule. The direct, quantitative and selective measurements of 12C and 13C isotopes of CH4 in ambient air as well as in human breath samples in the levels of parts per billion by volume were made by probing one of the strongest fundamental vibrational transitions of CH4 arising from the asymmetric bending (ν 4 band) vibrations of the bonds centred at ~1327.244 cm-1 and ~1332.946 cm-1, respectively. We achieved a noise-equivalent absorption coefficient of 1.86  ×  10-9 cm-1 Hz-1/2 with 100 Hz data acquisition rate for the current cw-CRDS spectrometer. The current high-resolution cw-CRDS system could be further exploited to harness the full advantage of the spectral region covering 7.5-8 µm to monitor several other trace molecular species along with their isotopic compositions.

  7. Investigation of short cavity CRDS noise terms by optical correlation

    NASA Astrophysics Data System (ADS)

    Griffin, Steven T.; Fathi, Jason

    2013-05-01

    Cavity Ring Down Spectroscopy (CRDS) has been identified as having significant potential for Department of Defense security and sensing applications. Significant factors in the development of new sensor architectures are portability, robustness and economy. A significant factor in new CRDS sensor architectures is cavity length. Prior publication has examined the role of cavity length in sensing modality both from the standpoint of the system's design and the identification of potential difficulties presented by novel approaches. Two of interest here are new noise terms that have been designated turbulence-like and speckle-like in prior publication. In the prior publication the theoretical and some empirical data was presented. This presentation addresses the automation of the experimental apparatus, new data analysis, and implications regarding the significance of the two noise terms. This is accomplished through an Analog-to- Digital Conversion (ADC) from the output of a custom designed optical correlator. Details of the unique application of the developed instrument and implications for short cavity (portable) CRDS applications are presented.

  8. PCF-Based Cavity Enhanced Spectroscopic Sensors for Simultaneous Multicomponent Trace Gas Analysis

    PubMed Central

    Nakaema, Walter M.; Hao, Zuo-Qiang; Rohwetter, Philipp; Wöste, Ludger; Stelmaszczyk, Kamil

    2011-01-01

    A multiwavelength, multicomponent CRDS gas sensor operating on the basis of a compact photonic crystal fibre supercontinuum light source has been constructed. It features a simple design encompassing one radiation source, one cavity and one detection unit (a spectrograph with a fitted ICCD camera) that are common for all wavelengths. Multicomponent detection capability of the device is demonstrated by simultaneous measurements of the absorption spectra of molecular oxygen (spin-forbidden b-X branch) and water vapor (polyads 4v, 4v + δ) in ambient atmospheric air. Issues related to multimodal cavity excitation, as well as to obtaining the best signal-to-noise ratio are discussed together with methods for their practical resolution based on operating the cavity in a “quasi continuum” mode and setting long camera gate widths, respectively. A comprehensive review of multiwavelength CRDS techniques is also given. PMID:22319372

  9. Absorption line metrology by optical feedback frequency-stabilized cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Burkart, Johannes; Kassi, Samir

    2015-04-01

    Optical feedback frequency-stabilized cavity ring-down spectroscopy (OFFS-CRDS) is a near-shot-noise-limited technique combining a sensitivity of with a highly linear frequency axis and sub-kHz resolution. Here, we give an in-depth review of the key elements of the experimental setup encompassing a highly stable V-shaped reference cavity, an integrated Mach-Zehnder modulator and a tightly locked ring-down cavity with a finesse of 450,000. Carrying out a detailed analysis of the spectrometer performance and its limitations, we revisit the photo-electron shot-noise limit in CRDS and discuss the impact of optical fringes. We demonstrate different active schemes for fringe cancelation by varying the phase of parasitic reflections. The proof-of-principle experiments reported here include a broadband high-resolution spectrum of carbon dioxide at 1.6 µm and an isolated line-shape measurement with a signal-to-noise ratio of 80,000. Beyond laboratory-based absorption line metrology for fundamental research, OFFS-CRDS holds a considerable potential for field laser measurements of trace gas concentrations and isotopic ratios by virtue of its small sample volume and footprint, the robust cavity-locking scheme and supreme precision.

  10. Quantifying methane emission from fugitive sources by combining tracer release and downwind measurements - a sensitivity analysis based on multiple field surveys.

    PubMed

    Mønster, Jacob G; Samuelsson, Jerker; Kjeldsen, Peter; Rella, Chris W; Scheutz, Charlotte

    2014-08-01

    Using a dual species methane/acetylene instrument based on cavity ring down spectroscopy (CRDS), the dynamic plume tracer dispersion method for quantifying the emission rate of methane was successfully tested in four measurement campaigns: (1) controlled methane and trace gas release with different trace gas configurations, (2) landfill with unknown emission source locations, (3) landfill with closely located emission sources, and (4) comparing with an Fourier transform infrared spectroscopy (FTIR) instrument using multiple trace gasses for source separation. The new real-time, high precision instrument can measure methane plumes more than 1.2 km away from small sources (about 5 kg h(-1)) in urban areas with a measurement frequency allowing plume crossing at normal driving speed. The method can be used for quantification of total methane emissions from diffuse area sources down to 1 kg per hour and can be used to quantify individual sources with the right choice of wind direction and road distance. The placement of the trace gas is important for obtaining correct quantification and uncertainty of up to 36% can be incurred when the trace gas is not co-located with the methane source. Measurements made at greater distances are less sensitive to errors in trace gas placement and model calculations showed an uncertainty of less than 5% in both urban and open-country for placing the trace gas 100 m from the source, when measurements were done more than 3 km away. Using the ratio of the integrated plume concentrations of tracer gas and methane gives the most reliable results for measurements at various distances to the source, compared to the ratio of the highest concentration in the plume, the direct concentration ratio and using a Gaussian plume model. Under suitable weather and road conditions, the CRDS system can quantify the emission from different sources located close to each other using only one kind of trace gas due to the high time resolution, while the FTIR system can measure multiple trace gasses but with a lower time resolution. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. High sensitivity detection of NO2 employing cavity ringdown spectroscopy and an external cavity continuously tunable quantum cascade laser.

    PubMed

    Rao, Gottipaty N; Karpf, Andreas

    2010-09-10

    A trace gas sensor for the detection of nitrogen dioxide based on cavity ringdown spectroscopy (CRDS) and a continuous wave external cavity tunable quantum cascade laser operating at room temperature has been designed, and its features and performance characteristics are reported. By measuring the ringdown times of the cavity at different concentrations of NO(2), we report a sensitivity of 1.2 ppb for the detection of NO(2) in Zero Air.

  12. Development of a cw-laser-based cavity-ringdown sensor aboard a spacecraft for trace air constituents

    NASA Technical Reports Server (NTRS)

    Awtry, A. R.; Miller, J. H.

    2002-01-01

    The progress in the development of a sensor for the detection of trace air constituents to monitor spacecraft air quality is reported. A continuous-wave (cw), external-cavity tunable diode laser centered at 1.55 micrometers is used to pump an optical cavity absorption cell in cw-cavity ringdown spectroscopy (cw-CRDS). Preliminary results are presented that demonstrate the sensitivity, selectivity and reproducibility of this method. Detection limits of 2.0 ppm for CO, 2.5 ppm for CO2, 1.8 ppm for H2O, 19.4 ppb for NH3, 7.9 ppb for HCN and 4.0 ppb for C2H2 are calculated.

  13. Direct Detection of C_2H_2 in Air and Human Breath by Cw-Crds

    NASA Astrophysics Data System (ADS)

    Schmidt, Florian M.; Vaittinen, Olavi; Metsälä, Markus; Halonen, Lauri

    2010-06-01

    Continuous wave cavity ring-down spectroscopy (cw-CRDS) is an established cavity-enhanced absorption technique that can provide the necessary sensitivity, selectivity and fast acquisition time for many applications involving the detection of trace species. We present a simple but highly sensitive cw-CRDS spectrometer based on an external cavity diode laser operating in the near-infrared region. This instrument allows us to directly detect acetylene (C_2H_2) mixing ratios in air with a detection limit of 120 parts per trillion by volume (pptv) measuring on a C_2H_2 absorption line at 6565.620 cm-1. Acetylene is a combustion product that is routinely used in environmental monitoring as a marker for anthropogenic emissions. In a recent work, the spectrometer was employed to measure the level of acetylene in indoor and outdoor air in Helsinki. Continuous flow measurements with high time resolution (one minute) revealed strong fluctuations in the acetylene mixing ratio in outdoor air during daytime. Due to its non-invasive nature and fast response time, the analysis of exhaled breath for medical diagnostics is an excellent and straightforward alternative to methods using urine or blood samples. In an ongoing study, the cw-CRDS instrument is used to establish the baseline level of acetylene in the breath of the healthy population. An elevated amount of acetylene in breath could indicate exposure to combustion exhausts or other volatile organic compound (VOC) rich sources. The latest results of this investigation will be presented. F. M. Schmidt, O. Vaittinen, M. Metsälä, P. Kraus and L. Halonen, submitted for publication in Appl. Phys. B.

  14. Sulfated Polysaccharide, Curdlan Sulfate, Efficiently Prevents Entry/Fusion and Restricts Antibody-Dependent Enhancement of Dengue Virus Infection In Vitro: A Possible Candidate for Clinical Application

    PubMed Central

    Zhang, Li Feng; Chin, Wei Xin; Muschin, Tegshi; Heinig, Lars; Suzuki, Youichi; Nanjundappa, Haraprasad; Yoshinaka, Yoshiyuki; Ryo, Akihide; Nomura, Nobuo; Ooi, Eng Eong; Vasudevan, Subhash G.; Yoshida, Takashi; Yamamoto, Naoki

    2013-01-01

    Curdlan sulfate (CRDS), a sulfated 1→3-β-D glucan, previously shown to be a potent HIV entry inhibitor, is characterized in this study as a potent inhibitor of the Dengue virus (DENV). CRDS was identified by in silico blind docking studies to exhibit binding potential to the envelope (E) protein of the DENV. CRDS was shown to inhibit the DENV replication very efficiently in different cells in vitro. Minimal effective concentration of CRDS was as low as 0.1 µg/mL in LLC-MK2 cells, and toxicity was observed only at concentrations over 10 mg/mL. CRDS can also inhibit DENV-1, 3, and 4 efficiently. CRDS did not inhibit the replication of DENV subgenomic replicon. Time of addition experiments demonstrated that the compound not only inhibited viral infection at the host cell binding step, but also at an early post-attachment step of entry (membrane fusion). The direct binding of CRDS to DENV was suggested by an evident reduction in the viral titers after interaction of the virus with CRDS following an ultrafiltration device separation, as well as after virus adsorption to an alkyl CRDS-coated membrane filter. The electron microscopic features also showed that CRDS interacted directly with the viral envelope, and caused changes to the viral surface. CRDS also potently inhibited DENV infection in DC-SIGN expressing cells as well as the antibody-dependent enhancement of DENV-2 infection. Based on these data, a probable binding model of CRDS to DENV E protein was constructed by a flexible receptor and ligand docking study. The binding site of CRDS was predicted to be at the interface between domains II and III of E protein dimer, which is unique to this compound, and is apparently different from the β-OG binding site. Since CRDS has already been tested in humans without serious side effects, its clinical application can be considered. PMID:23658845

  15. Cone rod dystrophies

    PubMed Central

    Hamel, Christian P

    2007-01-01

    Cone rod dystrophies (CRDs) (prevalence 1/40,000) are inherited retinal dystrophies that belong to the group of pigmentary retinopathies. CRDs are characterized by retinal pigment deposits visible on fundus examination, predominantly localized to the macular region. In contrast to typical retinitis pigmentosa (RP), also called the rod cone dystrophies (RCDs) resulting from the primary loss in rod photoreceptors and later followed by the secondary loss in cone photoreceptors, CRDs reflect the opposite sequence of events. CRD is characterized by primary cone involvement, or, sometimes, by concomitant loss of both cones and rods that explains the predominant symptoms of CRDs: decreased visual acuity, color vision defects, photoaversion and decreased sensitivity in the central visual field, later followed by progressive loss in peripheral vision and night blindness. The clinical course of CRDs is generally more severe and rapid than that of RCDs, leading to earlier legal blindness and disability. At end stage, however, CRDs do not differ from RCDs. CRDs are most frequently non syndromic, but they may also be part of several syndromes, such as Bardet Biedl syndrome and Spinocerebellar Ataxia Type 7 (SCA7). Non syndromic CRDs are genetically heterogeneous (ten cloned genes and three loci have been identified so far). The four major causative genes involved in the pathogenesis of CRDs are ABCA4 (which causes Stargardt disease and also 30 to 60% of autosomal recessive CRDs), CRX and GUCY2D (which are responsible for many reported cases of autosomal dominant CRDs), and RPGR (which causes about 2/3 of X-linked RP and also an undetermined percentage of X-linked CRDs). It is likely that highly deleterious mutations in genes that otherwise cause RP or macular dystrophy may also lead to CRDs. The diagnosis of CRDs is based on clinical history, fundus examination and electroretinogram. Molecular diagnosis can be made for some genes, genetic counseling is always advised. Currently, there is no therapy that stops the evolution of the disease or restores the vision, and the visual prognosis is poor. Management aims at slowing down the degenerative process, treating the complications and helping patients to cope with the social and psychological impact of blindness. PMID:17270046

  16. Modifications to a Cavity Ringdown Spectrometer to Improve Data Acquisition Rates

    NASA Astrophysics Data System (ADS)

    Bostrom, Gregory Alan

    Cavity ringdown spectroscopy (CRDS) makes use of light retention in an optical cavity to enhance the sensitivity to absorption or extinction of light from a sample inside the cavity. When light entering the cavity is stopped, the output is an exponential decay with a decay constant that can be used to determine the quantity of the analyte if the extinction or absorption coefficient is known. The precision of the CRDS is dependent on the rate at which the system it acquires and processes ringdowns, assuming randomly distributed errors. We have demonstrated a CRDS system with a ringdown acquisition rate of 1.5 kHz, extendable to a maximum of 3.5 kHz, using new techniques that significantly changed the way in which the ringdowns are both initiated and processed. On the initiation side, we combined a custom high-resolution laser controller with a linear optical feedback configuration and a novel optical technique for initiating a ringdown. Our optical injection "unlock" method switches the laser off-resonance, while allowing the laser to immediately return to resonance, after terminating the unlock, to allow for another ringdown (on the same cavity resonance mode). This part of the system had a demonstrated ringdown initiation rate of 3.5 kHz. To take advantage of this rate, we developed an optimized cost-effective FGPA-based data acquisition and processing system for CRDS, capable of determining decay constants at a maximum rate of 4.4 kHz, by modifying a commercial ADC-FPGA evaluation board and programming it to apply a discrete Fourier transform-based algorithm for determining decay constants. The entire system shows promise with a demonstrated ability to determine gas concentrations for H2O with a measured concentration accuracy of +/-3.3%. The system achieved an absorption coefficient precision of 0.1% (95% confidence interval). It also exhibited a linear response for varying H2O concentrations, a 2.2% variation (1sigma) for repeated measurements at the same H2O concentration, and a corresponding precision of 0.6% (standard error of the mean). The absorption coefficient limit of detection was determined to be 1.6 x 10-8 cm -1 (root mean square of the baseline residual). Proposed modifications to our prototype system offer the promise of more substantial gains in both precision and limit of detection. The system components developed here for faster ringdown acquisition and processing have broader applications for CRDS in atmospheric science and other fields that need fast response systems operating at high-precision.

  17. Microcontroller based resonance tracking unit for time resolved continuous wave cavity-ringdown spectroscopy measurements.

    PubMed

    Votava, Ondrej; Mašát, Milan; Parker, Alexander E; Jain, Chaithania; Fittschen, Christa

    2012-04-01

    We present in this work a new tracking servoloop electronics for continuous wave cavity-ringdown absorption spectroscopy (cw-CRDS) and its application to time resolved cw-CRDS measurements by coupling the system with a pulsed laser photolysis set-up. The tracking unit significantly increases the repetition rate of the CRDS events and thus improves effective time resolution (and/or the signal-to-noise ratio) in kinetics studies with cw-CRDS in given data acquisition time. The tracking servoloop uses novel strategy to track the cavity resonances that result in a fast relocking (few ms) after the loss of tracking due to an external disturbance. The microcontroller based design is highly flexible and thus advanced tracking strategies are easy to implement by the firmware modification without the need to modify the hardware. We believe that the performance of many existing cw-CRDS experiments, not only time-resolved, can be improved with such tracking unit without any additional modification to the experiment. © 2012 American Institute of Physics

  18. High burden of Aspergillus fumigatus infection among chronic respiratory diseases.

    PubMed

    Fukuda, Yosuke; Homma, Tetsuya; Suzuki, Shintaro; Takuma, Takahiro; Tanaka, Akihiko; Yokoe, Takuya; Ohnishi, Tsukasa; Niki, Yoshihito; Sagara, Hironori

    2018-01-01

    Aspergillus fumigatus (AF) is a ubiquitous fungus in our environment and causes severe airway disorders. Chronic respiratory diseases (CRDs) are a series of chronic airway and lung diseases. Although both are chronic disorders, however, the relationships between AF and CRDs are still unclear. Therefore, we examined 104 Aspergillus species (spp.) isolated samples in our hospital during three consecutive years to further elucidate the relationships between Aspergillus spp. and CRDs. Based on sample isolates, we then grouped these into two groups, AF and non-AF, to retrospectively analyse the clinical features and to clarify the relationships between AF and CRDs. Importantly, the manifestation of CRD was more frequent in the AF group than in the non-AF group ( p = 0.035). Among CRDs, lung fibrosis was more evident in the AF group ( p = 0.025). Moreover, diabetes mellitus was tended to be evident in AF group than non-AF group ( p = 0.035). In conclusion, CRDs, especially lung fibrosis, were highly prevalent in AF group than non-AF group.

  19. Real-time trace ambient ammonia monitor for haze prevention

    NASA Astrophysics Data System (ADS)

    Nishimura, Katsumi; Sakaguchi, Yuhei; Crosson, Eric; Wahl, Edward; Rella, Chris

    2007-05-01

    In photolithography, haze prevention is of critical importance to integrated circuit chip manufacturers. Numerous studies have established that the presence of ammonia in the photolithography tool can cause haze to form on optical surfaces resulting in permanent damage to costly deep ultra-violet optics. Ammonia is emitted into wafer fab air by various semiconductor processes including coating steps in the track and CMP. The workers in the clean room also emit a significant amount of ammonia. Chemical filters are typically used to remove airborne contamination from critical locations but their lifetime and coverage cannot offer complete protection. Therefore, constant or periodic monitoring of airborne ammonia at parts-per-trillion (ppt) levels is critical to insure the integrity of the lithography process. Real time monitoring can insure that an accidental ammonia release in the clean room is detected before any optics is damaged. We have developed a transportable, highly accurate, highly specific, real-time trace gas monitor that detects ammonia using Cavity Ring-Down Spectroscopy (CRDS). The trace gas monitor requires no calibration gas standards, and can measure ammonia with 200 ppt sensitivity in five minutes with little or no baseline drift. In addition, the high spectral resolution of CRDS makes the analyzer less susceptible to interference from other gases when compared to other detection methods. In this paper we describe the monitor, focus on its performance, discuss the results of a careful comparison with ion chromatography (IC), and present field data measured inside the aligner and the reticule stocker at a semiconductor fab.

  20. The Calibration Reference Data System

    NASA Astrophysics Data System (ADS)

    Greenfield, P.; Miller, T.

    2016-07-01

    We describe a software architecture and implementation for using rules to determine which calibration files are appropriate for calibrating a given observation. This new system, the Calibration Reference Data System (CRDS), replaces what had been previously used for the Hubble Space Telescope (HST) calibration pipelines, the Calibration Database System (CDBS). CRDS will be used for the James Webb Space Telescope (JWST) calibration pipelines, and is currently being used for HST calibration pipelines. CRDS can be easily generalized for use in similar applications that need a rules-based system for selecting the appropriate item for a given dataset; we give some examples of such generalizations that will likely be used for JWST. The core functionality of the Calibration Reference Data System is available under an Open Source license. CRDS is briefly contrasted with a sampling of other similar systems used at other observatories.

  1. A widely-tunable and sensitive optical sensor for multi-species detection in the mid-IR

    NASA Astrophysics Data System (ADS)

    Alquaity, Awad B. S.; Al-Saif, Bidoor; Farooq, Aamir

    2018-01-01

    Pulsed cavity ringdown spectroscopy (CRDS) technique was used to develop a novel widely-tunable laser-based sensor for sensitive measurements of ethylene, propene, 1-butene and allene in the mid-IR. The use of an external-cavity quantum cascade laser (EC-QCL) enabled the sensor to cover a wide wavelength range from 10 to 11.1 µm (900-1000 cm-1) to detect multiple gases relevant to combustion and environment. The sensor operation was validated in a room-temperature static cell using well-characterized absorption lines of carbon dioxide near 938.69 cm-1 and 974.62 cm-1. Detection limits for ethylene, propene, 1-butene, and allene were measured to be 17, 134, 754 and 378 ppb, respectively, at 296 K and 760 Torr for a single-pass path-length of 70 cm with averaging time of 4 ms. The excellent sensitivity of the optical sensor enabled it to measure the aforementioned gases at levels smaller than 1% of their recommended exposure limits. To the best of our knowledge, this is one of the first successful applications of the pulsed CRDS technique to measure trace levels of multiple gases in the 10-11 µm wavelength region.

  2. Open Path Trace Gas Laser Sensors for UAV Deployment

    NASA Astrophysics Data System (ADS)

    Shadman, S.; Mchale, L.; Rose, C.; Yalin, A.

    2015-12-01

    Novel trace gas sensors based on open-path Cavity Ring-down Spectroscopy (CRDS) are being developed to enable remote and mobile deployments including on small unmanned aerial systems (UAS). Relative to established closed-path CRDS instruments, the use of open-path configurations allows removal of the bulky and power hungry vacuum and flow system, potentially enabling lightweight and low power instruments with high sensitivity. However, open path operation introduces new challenges including the need to maintain mirror cleanliness, mitigation of particle optical effects, and the need to measure spectral features that are relatively broad. The present submission details open-path CRDS instruments for ammonia and methane and their planned use in UAS studies. The ammonia sensor uses a quantum cascade laser at 10.3 mm in a configuration in which the laser frequency is continuously swept and a trigger circuit and acousto-optic modulator (AOM) extinguish the light when the laser is resonant with the cavity. Ring-down signals are measured with a two-stage thermoelectrically cooled MCT photodetector. The cavity mirrors have reflectivity of 0.9995 and a noise equivalent absorption of 1.5 ppb Hz-1/2 was demonstrated. A first version of the methane sensor operated at 1.7um with a telecom diode laser while the current version operates at 3.6 um with an interband cascade laser (stronger absorption). We have performed validation measurements against known standards for both sensors. Compact optical assemblies are being developed for UAS deployment. For example, the methane sensor head will have target mass of <4 kg and power draw <40 W. A compact single board computer and DAQ system is being designed for sensor control and signal processing with target mass <1 kg and power draw <10 W. The sensor size and power parameters are suitable for UAS deployment on both fixed wing and rotor style UAS. We plan to deploy the methane sensor to measure leakage and emission of methane from natural gas infrastructure, and to deploy both sensors together to study emissions from dairies and feedlots. The latter measurement campaign will also examine ammonia deposition to the ground, and bi-directional ammonia fluxes, using methane as a conservative tracer and examining the change in the ratio of ammonia to methane as a function of downwind position.

  3. Laser Spectroscopy for Atmospheric and Environmental Sensing

    PubMed Central

    Fiddler, Marc N.; Begashaw, Israel; Mickens, Matthew A.; Collingwood, Michael S.; Assefa, Zerihun; Bililign, Solomon

    2009-01-01

    Lasers and laser spectroscopic techniques have been extensively used in several applications since their advent, and the subject has been reviewed extensively in the last several decades. This review is focused on three areas of laser spectroscopic applications in atmospheric and environmental sensing; namely laser-induced fluorescence (LIF), cavity ring-down spectroscopy (CRDS), and photoluminescence (PL) techniques used in the detection of solids, liquids, aerosols, trace gases, and volatile organic compounds (VOCs). PMID:22303184

  4. Overview: MURI Center on spectroscopic and time domain detection of trace explosives in condensed and vapor phases

    NASA Astrophysics Data System (ADS)

    Spicer, James B.; Dagdigian, Paul; Osiander, Robert; Miragliotta, Joseph A.; Zhang, Xi-Cheng; Kersting, Roland; Crosley, David R.; Hanson, Ronald K.; Jeffries, Jay

    2003-09-01

    The research center established by Army Research Office under the Multidisciplinary University Research Initiative program pursues a multidisciplinary approach to investigate and advance the use of complementary analytical techniques for sensing of explosives and/or explosive-related compounds as they occur in the environment. The techniques being investigated include Terahertz (THz) imaging and spectroscopy, Laser-Induced Breakdown Spectroscopy (LIBS), Cavity Ring Down Spectroscopy (CRDS) and Resonance Enhanced Multiphoton Ionization (REMPI). This suite of techniques encompasses a diversity of sensing approaches that can be applied to detection of explosives in condensed phases such as adsorbed species in soil or can be used for vapor phase detection above the source. Some techniques allow for remote detection while others have highly specific and sensitive analysis capabilities. This program is addressing a range of fundamental, technical issues associated with trace detection of explosive related compounds using these techniques. For example, while both LIBS and THz can be used to carry-out remote analysis of condensed phase analyte from a distance in excess several meters, the sensitivities of these techniques to surface adsorbed explosive-related compounds are not currently known. In current implementations, both CRDS and REMPI require sample collection techniques that have not been optimized for environmental applications. Early program elements will pursue the fundamental advances required for these techniques including signature identification for explosive-related compounds/interferents and trace analyte extraction. Later program tasks will explore simultaneous application of two or more techniques to assess the benefits of sensor fusion.

  5. High-Precision Measurement of 13C/12C Isotopic Ratio Using Gas Chromatography-Combustion-Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Saad, N.; Kuramoto, D. S.; Haase, C.; Crosson, E.; Tan, S.; Zare, R. N.

    2009-12-01

    Light stable isotope analysis, and in particular, compound specific isotopic analysis (CSIA), is a valuable tool to elucidate pathways and provide a better insight into biological, ecological, and geological systems. We present here the results of compound-specific isotopic carbon analysis of short chain hydrocarbons using the world’s first combination of gas chromatography, combustion interface, and cavity ring-down spectroscopy (GC-C-CRDS). Cavity ring-down spectroscopy (CRDS) is a highly sensitive optical spectroscopy, one application of which is to measure the stable isotopic ratios in small molecules. Because it uses a highly reflective optical cavity with many kilometers effective path length, CRDS provides some of the most sensitive and precise optical absorption measurements. Most optical spectroscopy isotopic analysis measures the quantities of each isotopologue independently using their distinct ro-vibrational spectra. The most common isotopes measured with optical spectroscopy are 13C and 12C in carbon dioxide. However, the isotopes of hydrogen, oxygen, and sulfur have also been measured. Unlike isotope ratio mass spectrometry (IRMS), optical spectroscopy can distinguish among isobars, which have essentially identical m/z ratios. The combination of chemical separation, chemical conversion, and CRDS makes a nearly universal tool for isotopic analysis of mixtures. In addition, CRDS can tolerate a variety of compounds mixed with the target. For example, CRDS can measure carbon dioxide and its isotopic 13C/12C ratio in the presence of oxygen. Using the novel GC-C-CRDS system, we injected a 75-microliter mixture of approximately equal quantities of methane, ethane, and propane into a gas chromatograph using helium as carrier gas. The methane, ethane, and propane were separated in time by 100 to 200 seconds after the chromatograph. Oxygen gas was added, and the hydrocarbons were combusted in a catalytic combustor with platinum and nickel, held at 1150oC. The combusted products were combined with dry nitrogen gas to provide sufficient gas flow for the CRDS analyzer, which measured the 13C/12C isotopic ratio of the separated methane, ethane, and propane, obtaining a precision of 0.95 permil or better. The calibration accuracy was within 3 permil of the values determined using IRMS. The current CRDS-based system is less expensive, does not require highly trained personnel to operate, and is portable, compared with IRMS. We anticipate that advances in spectroscopic analysis will improve the precision and accuracy of the CRDS isotopic measurement, making it comparable with IRMS.

  6. Validation of spectroscopic gas analyzer accuracy using gravimetric standard gas mixtures: impact of background gas composition on CO2 quantitation by cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Lim, Jeong Sik; Park, Miyeon; Lee, Jinbok; Lee, Jeongsoon

    2017-12-01

    The effect of background gas composition on the measurement of CO2 levels was investigated by wavelength-scanned cavity ring-down spectrometry (WS-CRDS) employing a spectral line centered at the R(1) of the (3 00 1)III ← (0 0 0) band. For this purpose, eight cylinders with various gas compositions were gravimetrically and volumetrically prepared within 2σ = 0.1 %, and these gas mixtures were introduced into the WS-CRDS analyzer calibrated against standards of ambient air composition. Depending on the gas composition, deviations between CRDS-determined and gravimetrically (or volumetrically) assigned CO2 concentrations ranged from -9.77 to 5.36 µmol mol-1, e.g., excess N2 exhibited a negative deviation, whereas excess Ar showed a positive one. The total pressure broadening coefficients (TPBCs) obtained from the composition of N2, O2, and Ar thoroughly corrected the deviations up to -0.5 to 0.6 µmol mol-1, while these values were -0.43 to 1.43 µmol mol-1 considering PBCs induced by only N2. The use of TPBC enhanced deviations to be corrected to ˜ 0.15 %. Furthermore, the above correction linearly shifted CRDS responses for a large extent of TPBCs ranging from 0.065 to 0.081 cm-1 atm-1. Thus, accurate measurements using optical intensity-based techniques such as WS-CRDS require TPBC-based instrument calibration or use standards prepared in the same background composition of ambient air.

  7. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Winderlich, J.; Gerbig, C.; Hoefer, A.; Rella, C. W.; Crosson, E. R.; van Pelt, A. D.; Steinbach, J.; Kolle, O.; Beck, V.; Daube, B. C.; Gottlieb, E. W.; Chow, V. Y.; Santoni, G. W.; Wofsy, S. C.

    2010-03-01

    High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR) analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4.

  8. Use and misuse of automobile child restraint devices.

    PubMed

    Margolis, L H; Wagenaar, A C; Molnar, L J

    1992-03-01

    To determine demographic, social, and behavioral characteristics that are associated with correct child restraint device (CRD) use. Cross-sectional. Fast-food restaurant parking lots in southeastern Michigan. Children younger than age 4 years and their drivers. Consecutive sample. None. Seven hundred seventeen child passengers were observed for 11 dimensions of CRD use and 661 of their drivers were interviewed. Three hundred ninety-four (55%) of the children were in CRDs, but 248 (63%) of those children were incorrectly restrained. A 43-point misuse index was constructed based on scores assigned for different types of misuse. Seven variables (ie, age of child, race of parent, driver as a parent, days driving, number of occupants, perceived comfort of CRDs, and belief that the social norm supports CRD use) were highly predictive of CRD use. In contrast, only three factors (ie, age of child, education of the driver, and knowledge of the CRD law) were minimally predictive of correct use. Since correct use of CRDs represents such a complex behavior, the best strategy to address the widespread problem of CRD use may be through the design of less complicated CRDs.

  9. Variable pathlength cavity spectroscopy development of an automated prototype

    NASA Astrophysics Data System (ADS)

    Schmeling, Ryan Andrew

    Spectroscopy is the study of the interaction of electromagnetic radiation (EMR) with matter to probe the chemical and physical properties of atoms and molecules. The primary types of analytical spectroscopy are absorption, emission, and scattering methods. Absorption spectroscopy can quantitatively determine the chemical concentration of a given species in a sample by the relationship described by Beer's Law. Upon inspection of Beer's Law, it becomes apparent that for a given analyte concentration, the only experimental variable is the pathlength. Over the past ˜75 years, several approaches to physically increasing the pathlength have been reported in the literature. These have included not only larger cuvettes and novel techniques such as Differential Optical Absorption Spectroscopy, but also numerous designs that are based upon the creation of an optical cavity in which multiple reflections through the sample are made possible. The cavity-based designs range from the White Cell (1942) to Cavity Ring-Down Spectroscopy (O'Keefe and Deacon, 1998). In the White Cell approach, the incident beam is directed off-axis to repeatedly reflect concave mirror surfaces. Numerous variations of the White Cell design have been reported, and it has found wide application in infrared absorption spectroscopy in what have become to be known as "light pipes". In the CRDS design, on the other hand, highly reflective dielectric mirrors situated for on-axis reflections result in the measurement of the exponential decay of trapped light that passes through the exit mirror. CRDS has proven over the past two decades to be a powerful technique for ultra-trace analysis (< 10-15 g), with practical applications ranging from atmospheric monitoring of greenhouse gases to biomedical "breath screening" as a means to identify disease states. In this thesis, a novel approach to ultra-trace analysis by absorption spectroscopy is described. In this approach known as Variable Pathlength Cavity Spectroscopy (VPCS), a high finesse optical cavity is created by two flat, parallel, dielectric mirrors -- one of which is rotating. Source light from a pulsed dye laser (488 nm) enters the optical cavity in the same manner as in Cavity Ring-Down Spectroscopy (CRDS), i.e., by passing through the cavity entrance mirror. However, unlike CRDS in which the mirrors are fixed, concave, and mechanically unaltered, the cavity exit mirror contains a slit (1.0 mm diameter) that is rotated at high speed on an axle, thereby transmitting a small fraction of the trapped light to a photomultiplier tube detector. In this approach, unlike CRDS, absorbance is measured directly. In previous prototype designs of the VPCS instrument, instrument control (alignment) and data acquisition and reduction were performed manually; these functions were both inefficient and tedious. Despite this, the VPCS was validated in "proof of concept" testing, as described with a previous prototype (Frost, 2011). Frost demonstrated that the pathlength enhancement increased 53-fold compared to single-pass absorption measurements in monitoring NO2 (g) at part-per-billion levels. The goal of the present work is to improve upon the previous prototype ("P4") that required manual alignment, data collection, and data reduction by creating a completely automated version of VPCS -- i.e., the "P5" prototype. By developing source code in LabVIEW(TM), demonstration that the VPCS can be completely controlled in an automated fashion is described. Computationally, a Field-Programmable Gate Array is used to automate the process of data collection and reduction in real-time. It is shown that the inputs and outputs of the P5 instrument can be continuously monitored, allowing for real-time triggering of the source laser, collection of all data, and reduction of the data to report absorbance. Furthermore, it is shown that the VPCS can be automatically aligned -- also in real-time on the order of microseconds -- to a high degree of precision by using servo-actuators that adjust the beam position based upon the input from a sensitive CCD camera. With the implementation of this hardware and LabVIEW code, more precise data collection and reduction is done. With this new fully automated design, the instrument characteristics (e.g., to include factors such as rotation speed, off-set angle, and pathlength variation) can improve the enhancement by ˜130-fold vs. single-pass absorption measurements.

  10. Rapid, Long-term Monitoring of CO2 Concentration and δ13CO2 at CCUS Sites Allows Discrimination of Leakage Patterns from Natural Background Values

    NASA Astrophysics Data System (ADS)

    Galfond, B.; Riemer, D. D.; Swart, P. K.

    2014-12-01

    In order for Carbon Capture Utilization and Storage (CCUS) to gain wide acceptance as a method for mitigating atmospheric CO2 concentrations, schemes must be devised to ensure that potential leakage is detected. New regulations from the US Environmental Protection Agency require monitoring and accounting for Class VI injection wells, which will remain a barrier to wide scale CCUS deployment until effective and efficient monitoring techniques have been developed and proven. Monitoring near-surface CO2 at injection sites to ensure safety and operational success requires high temporal resolution CO2 concentration and carbon isotopic (δ13C) measurements. The only technologies currently capable of this rapid measurement of δ13C are optical techniques such as Cavity Ringdown Spectroscopy (CRDS). We have developed a comprehensive remote monitoring approach using CRDS and a custom manifold system to obtain accurate rapid measurements from a large sample area over an extended study period. Our modified Picarro G1101-i CRDS allows for automated rapid and continuous field measurement of δ13CO2 and concentrations of relevant gas species. At our field site, where preparations have been underway for Enhanced Oil Recovery (EOR) operations, we have been able to measure biogenic effects on a diurnal scale, as well as variation due to precipitation and seasonality. Taking these background trends into account, our statistical treatment of real data has been used to improve signal-to-noise ratios by an order of magnitude over published models. Our system has proven field readiness for the monitoring of sites with even modest CO2 fluxes.

  11. High-resolution spectral analysis of ammonia near 6.2 μm using a cw EC-QCL coupled with cavity ring-down spectroscopy.

    PubMed

    Maithani, Sanchi; Mandal, Santanu; Maity, Abhijit; Pal, Mithun; Pradhan, Manik

    2018-04-30

    We report on the development of a mid-infrared cavity ring-down spectrometer (CRDS) coupled with a continuous wave (cw) external cavity quantum cascade laser (EC-QCL), operating between 6.0 μm and 6.3 μm, for high-resolution spectroscopic studies of ammonia (NH3) which served as a bench-mark molecule in this spectral region. We characterized the EC-QCL based CRDS system in detail and achieved a noise-equivalent absorption (NEA) coefficient of 2.11 × 10-9 cm-1 Hz-1/2 for a 100 Hz data acquisition rate. We thereafter exploited the system for high-resolution spectroscopic analysis of interference-free 10 transition lines of the ν4 fundamental vibrational band of NH3 centred at ∼6.2 μm. We probed the strongest interference-free absorption line RQ(4,3) of ν4, centred at 1613.370 cm-1 for highly-sensitive trace detection of NH3 and subsequently achieved a minimum detection sensitivity (1σ) of 2.78 × 109 molecules per cm3 which translated into the detection limit of 740 parts-per-trillion by volume (pptv/10-12) at a pressure of 115 Torr for an integration time of ∼167 seconds. To demonstrate the efficacy of the present system in real-life applications, we finally measured the mixing ratios of NH3 present in ambient air and human exhaled breath with high sensitivity and molecular specificity.

  12. Continuous wave cavity ring down spectroscopy measurements of velocity distribution functions of argon ions in a helicon plasma.

    PubMed

    Chakraborty Thakur, Saikat; McCarren, Dustin; Carr, Jerry; Scime, Earl E

    2012-02-01

    We report continuous wave cavity ring down spectroscopy (CW-CRDS) measurements of ion velocity distribution functions (VDFs) in low pressure argon helicon plasma (magnetic field strength of 600 G, T(e) ≈ 4 eV and n ≈ 5 × 10(11) cm(-3)). Laser induced fluorescence (LIF) is routinely used to measure VDFs of argon ions, argon neutrals, helium neutrals, and xenon ions in helicon sources. Here, we describe a CW-CRDS diagnostic based on a narrow line width, tunable diode laser as an alternative technique to measure VDFs in similar regimes but where LIF is inapplicable. Being an ultra-sensitive, cavity enhanced absorption spectroscopic technique; CW-CRDS can also provide a direct quantitative measurement of the absolute metastable state density. The proof of principle CW-CRDS measurements presented here are of the Doppler broadened absorption spectrum of Ar II at 668.6138 nm. Extrapolating from these initial measurements, it is expected that this diagnostic is suitable for neutrals and ions in plasmas ranging in density from 1 × 10(9) cm(-3) to 1 × 10(13) cm(-3) and target species temperatures less than 20 eV.

  13. Continuous wave cavity ring down spectroscopy measurements of velocity distribution functions of argon ions in a helicon plasma

    NASA Astrophysics Data System (ADS)

    Chakraborty Thakur, Saikat; McCarren, Dustin; Carr, Jerry; Scime, Earl E.

    2012-02-01

    We report continuous wave cavity ring down spectroscopy (CW-CRDS) measurements of ion velocity distribution functions (VDFs) in low pressure argon helicon plasma (magnetic field strength of 600 G, Te ≈ 4 eV and n ≈ 5 × 1011 cm-3). Laser induced fluorescence (LIF) is routinely used to measure VDFs of argon ions, argon neutrals, helium neutrals, and xenon ions in helicon sources. Here, we describe a CW-CRDS diagnostic based on a narrow line width, tunable diode laser as an alternative technique to measure VDFs in similar regimes but where LIF is inapplicable. Being an ultra-sensitive, cavity enhanced absorption spectroscopic technique; CW-CRDS can also provide a direct quantitative measurement of the absolute metastable state density. The proof of principle CW-CRDS measurements presented here are of the Doppler broadened absorption spectrum of Ar II at 668.6138 nm. Extrapolating from these initial measurements, it is expected that this diagnostic is suitable for neutrals and ions in plasmas ranging in density from 1 × 109 cm-3 to 1 × 1013 cm-3 and target species temperatures less than 20 eV.

  14. Continuous wave cavity ring-down spectroscopy for velocity distribution measurements in plasma.

    PubMed

    McCarren, D; Scime, E

    2015-10-01

    We report the development of a continuous wave cavity ring-down spectroscopic (CW-CRDS) diagnostic for real-time, in situ measurement of velocity distribution functions of ions and neutral atoms in plasma. This apparatus is less complex than conventional CW-CRDS systems. We provide a detailed description of the CW-CRDS apparatus as well as measurements of argon ions and neutrals in a high-density (10(9) cm(-3) < plasma density <10(13) cm(-3)) plasma. The CW-CRDS measurements are validated through comparison with laser induced fluorescence measurements of the same absorbing states of the ions and neutrals.

  15. Structure and Specificity of a Binary Tandem Domain F-Lectin from Striped Bass (Morone saxatilis)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bianchet, M.; Odom, E; Vasta, J

    2010-01-01

    The plasma of the striped bass Morone saxatilis contains a fucose-specific lectin (MsaFBP32) that consists of two F-type carbohydrate recognition domains (CRDs) in tandem. The crystal structure of the complex of MsaFBP32 with l-fucose reported here shows a cylindrical 81-A-long and 60-A-wide trimer divided into two globular halves: one containing N-terminal CRDs (N-CRDs) and the other containing C-terminal CRDs (C-CRDs). The resulting binding surfaces at the opposite ends of the cylindrical trimer have the potential to cross-link cell surface or humoral carbohydrate ligands. The N-CRDs and C-CRDs of MsaFBP32 exhibit significant structural differences, suggesting that they recognize different glycans. Analysismore » of the carbohydrate binding sites provides the structural basis for the observed specificity of MsaFBP32 for simple carbohydrates and suggests that the N-CRD recognizes more complex fucosylated oligosaccharides and with a relatively higher avidity than the C-CRD. Modeling of MsaFBP32 complexed with fucosylated glycans that are widely distributed in prokaryotes and eukaryotes rationalizes the observation that binary tandem CRD F-type lectins function as opsonins by cross-linking 'non-self' carbohydrate ligands and 'self' carbohydrate ligands, such as sugar structures displayed by microbial pathogens and glycans on the surface of phagocytic cells from the host.« less

  16. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) during BARCA

    NASA Astrophysics Data System (ADS)

    Chen, H.; Winderlich, J.; Gerbig, C.; Hoefer, A.; Rella, C. W.; Crosson, E. R.; van Pelt, A. D.; Steinbach, J.; Kolle, O.; Beck, V.; Daube, B. C.; Gottlieb, E. W.; Chow, V. Y.; Santoni, G. W.; Wofsy, S. C.

    2009-12-01

    High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR) analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4.

  17. CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window.

    PubMed

    Čermák, P; Chomet, B; Ferrieres, L; Vasilchenko, S; Mondelain, D; Kassi, S; Campargue, A; Denet, S; Lecocq, V; Myara, M; Cerutti, L; Garnache, A

    2016-08-01

    The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10(-11) cm(-1)) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm(-1) around 4300 cm(-1) together with a powerful (∼5 mW) TEM00 diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of the very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.

  18. CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Čermák, P., E-mail: cermak@fmph.uniba.sk; CNRS, LIPhy, UMR 5588, F-38000 Grenoble; Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská Dolina, 842 48 Bratislava

    2016-08-15

    The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10{sup −11} cm{sup −1}) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm{sup −1} around 4300 cm{sup −1} together with a powerful (∼5 mW) TEM{sub 00} diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of themore » very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.« less

  19. Continuous wave cavity ring-down spectroscopy for velocity distribution measurements in plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCarren, D.; Lockheed Martin, Palmdale, California 93599; Scime, E., E-mail: earl.scime@mail.wvu.edu

    2015-10-15

    We report the development of a continuous wave cavity ring-down spectroscopic (CW-CRDS) diagnostic for real-time, in situ measurement of velocity distribution functions of ions and neutral atoms in plasma. This apparatus is less complex than conventional CW-CRDS systems. We provide a detailed description of the CW-CRDS apparatus as well as measurements of argon ions and neutrals in a high-density (10{sup 9} cm{sup −3} < plasma density <10{sup 13} cm{sup −3}) plasma. The CW-CRDS measurements are validated through comparison with laser induced fluorescence measurements of the same absorbing states of the ions and neutrals.

  20. Socioeconomic disparities and chronic respiratory diseases in Thailand: The National Socioeconomics Survey.

    PubMed

    Luenam, Amornrat; Laohasiriwong, Wongsa; Puttanapong, Nattapong; Saengsuwan, Jiamjit; Phajan, Teerasak

    2018-05-10

    This study aimed to determine the association between socioeconomic determinants and Chronic Respiratory Diseases (CRDs) in Thailand. The data were used from the National Socioeconomics Survey (NSS), a cross-sectional study conducted by the National Statistical Office (NSO), in 2010 and 2012. The survey used stratified two-stage sampling to select a nationally representative sample to respond to a structured questionnaire. A total of 17,040 and 16,905 individuals in 2010 and 2012, respectively, were included in this analysis. Multiple logistic regressions were used to identify the association between socioeconomic factors while controlling for other covariates. The prevalence of CRDs was 3.81% and 2.79% in 2010 and 2012, respectively. The bivariate analysis indicated that gender, family size, geographic location, fuels used for cooking and smoking were significantly associated with CRDs in 2010, whereas education, family size, occupation, region, geographic location, and smoking were significantly associated with CRDs in 2012. Both in 2010 and 2012, the multiple logistic regression indicated that the odds of having CRDs were significantly higher among those who lived in urban areas, females, those aged ≥41-50 or ≥61 yr old, and smokers when controlling for other covariates. However, fuels used for cooking, wood and gas, are associated with CRDs in 2010.

  1. Cysteine-rich domains related to Frizzled receptors and Hedgehog-interacting proteins

    PubMed Central

    Pei, Jimin; Grishin, Nick V

    2012-01-01

    Frizzled and Smoothened are homologous seven-transmembrane proteins functioning in the Wnt and Hedgehog signaling pathways, respectively. They harbor an extracellular cysteine-rich domain (FZ-CRD), a mobile evolutionary unit that has been found in a number of other metazoan proteins and Frizzled-like proteins in Dictyostelium. Domains distantly related to FZ-CRDs, in Hedgehog-interacting proteins (HHIPs), folate receptors and riboflavin-binding proteins (FRBPs), and Niemann-Pick Type C1 proteins (NPC1s), referred to as HFN-CRDs, exhibit similar structures and disulfide connectivity patterns compared with FZ-CRDs. We used computational analyses to expand the homologous set of FZ-CRDs and HFN-CRDs, providing a better understanding of their evolution and classification. First, FZ-CRD-containing proteins with various domain compositions were identified in several major eukaryotic lineages including plants and Chromalveolata, revealing a wider phylogenetic distribution of FZ-CRDs than previously recognized. Second, two new and distinct groups of highly divergent FZ-CRDs were found by sensitive similarity searches. One of them is present in the calcium channel component Mid1 in fungi and the uncharacterized FAM155 proteins in metazoans. Members of the other new FZ-CRD group occur in the metazoan-specific RECK (reversion-inducing-cysteine-rich protein with Kazal motifs) proteins that are putative tumor suppressors acting as inhibitors of matrix metalloproteases. Finally, sequence and three-dimensional structural comparisons helped us uncover a divergent HFN-CRD in glypicans, which are important morphogen-binding heparan sulfate proteoglycans. Such a finding reinforces the evolutionary ties between the Wnt and Hedgehog signaling pathways and underscores the importance of gene duplications in creating essential signaling components in metazoan evolution. PMID:22693159

  2. Analysis of Cloud-Based Database Systems

    DTIC Science & Technology

    2015-06-01

    EU) citizens under the Patriot Act [3]. Unforeseen virtualization bugs have caused wide-reaching outages [4], leaving customers helpless to assist...collected from SQL Server Profiler traces. We analyze the trace results captured from our test bed both before and after increasing system resources...cloud test- bed . A. DATA COLLECTION, PARSING, AND ORGANIZATION Once we finished collecting the trace data, we knew we needed to have as close a

  3. Full 3-D OCT-based pseudophakic custom computer eye model

    PubMed Central

    Sun, M.; Pérez-Merino, P.; Martinez-Enriquez, E.; Velasco-Ocana, M.; Marcos, S.

    2016-01-01

    We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608

  4. Pulse labelling for carbon turnover measurements with a CRDS for wetlands - challenges and solutions

    NASA Astrophysics Data System (ADS)

    Strozecki, Marcin; Samson, Mateusz; Chojnicki, Bogdan H.; Leśny, Jacek; Moni, Christophe; Urbaniak, Marek; Olejnik, Janusz; Juszczak, Radosław; Silvennoinnen, Hanna

    2016-04-01

    Carbon turnover in peatlands has commonly been studied by estimating carbon allocation and decomposition rates by litterbags, assessing changes in carbon stocks and by measuring the biosphere-atmosphere exchange of carbon gases with various chamber methods or by eddy covariance. In addition, C turnover rates have been measured with pulse labelling methods using 13C and 14C (e.g. Bahn et al. 2009). Pulse labeling (PL) studies in wetlands are, however, sparse (e.g. Gao et al. 2015), presumably as descriptive high water table levels and relatively low productivity render successful tracing difficult. Quite low cost fast-gas-analyzers (Cavity Ring Down Spectrometry, CRDS) make PL experiments more cost-worthy, but their applicability at wetland field and further for measuring elevated 13C - levels is challenging. We carried out a PL as a pre-experiment for a larger labelling campaign of the Wetman-project at Rzecin wetland in Poland. We aimed at defining 1) The optimum labeling for the peatland site, 2) The importance of dissolved 13CO2 both for the loss of the pulse label and for the potential bias to respiratory flux, 3) The reliability of the 13CO2 and 13CH4 measurements when using dynamic closed chambers with a factory calibrated CRDS. We labelled the study area by a transparent chamber combined to Picarro CRDS G2201-i (C input during labelling 4.9 μg 13C). After labelling, we monitored the respiratory 13CO2 flux and the 13CO2 content in the peat water over a 10d- period. In addition, we measured the vegetation13C before labelling and 10 days after. Plants assimilated 2.1 μg C of the added 13C. Half of the recovered 13CO2 (3.6 μg C) originated from respiration. Nearly one third of added 13CO2 immediately dissolved in the water, which at the end of the experiment retained 0.5 μg 13C. Finally, 127 % of the added label was recovered. The high recovery was mainly caused by overestimation in the δ13C. The results of our pre-experiment indicate that 1) Measuring dissolved gases is required for correcting the biases to the respiratory flux 2) the Picarro CRDS has to be thoroughly calibrated for linearity and for δ13C at different signatures. As a result, we developed calibration methods suitable for field conditions and for higher labels. The Research was co-founded by the Polish National Centre for Research and Development within the Polish-Norwegian Research Programme within the project WETMAN (Central European Wetland Ecosystem Feedbacks to Changing Climate - Field Scale Manipulation, Project ID: 203258, contract No. Pol-Nor/203258/31/2013 (www.wetman.pl). Bahn, M. et al., 2009. The New phytologist, Gao, J. et al., 2015. Scientific Reports,

  5. A Comparison of Laser Induced Florescence and Continuous Wave Ring Down Spectroscopy Measurements of Argon Ion and Neutral VDFs in a Helicon Plasma

    NASA Astrophysics Data System (ADS)

    McCarren, Dustin; Vandervort, Robert; Carr, Jerry, Jr.; Scime, Earl

    2012-10-01

    In this work, we compare two spectroscopic methods for measuring the velocity distribution functions (VDFs) of argon ions and neutrals in a helicon plasma: laser induced florescence (LIF) and continuous wave cavity ring down spectroscopy (CW-CRDS). An established and powerful technique, LIF suffers from the requirement that the initial state of the LIF sequence have a substantial density. In most cases, this requirement limits LIF to ions and atoms with large metastable state densities for the given plasma conditions. CW-CRDS is considerably more sensitive than LIF and can potentially be applied to much lower density populations of ion and atom states. However, CRDS is a line integrated technique that lacks the spatial resolution of LIF. CRDS is a proven, ultra-sensitive, cavity enhanced absorption spectroscopy technique and when combined with a CW diode laser that has a sufficiently narrow linewidth, the Doppler broadened absorption line, i.e., the VDFs, can be measured. We present CW-CRDS and LIF measurements of the VDFs in an argon plasma using the 668.614 nm (in vacuum) line of Ar II and the 667.9125 nm (in vacuum) line of Ar I.

  6. Effect of Baseline Anxiety and Depression Symptoms on Selected Outcomes Following Pulmonary Rehabilitation.

    PubMed

    Cullen, Kate; Talbot, Daniel; Gillmor, Julie; McGrath, Colin; OʼDonnell, Rory; Baily-Scanlan, Maria; Broderick, Julie

    2017-07-01

    Anxiety and depression are prevalent comorbidities in people with chronic respiratory diseases (CRDs). This study sought to quantify the influence of varying degrees of anxiety and depression on functional performance and disease impact in a population with CRDs following pulmonary rehabilitation (PR) intervention. The Hospital Anxiety and Depression Scale (HADS), the 6-Minute Walk Test (6MWT), and the Chronic Obstructive Pulmonary Disease Assessment Test (CAT) were assessed pre- and post-PR. Participants were categorized into 3 groups (None, Probable, and Present) based on their level of anxiety and depression. Functional performance and disease impact outcomes were compared pre- and post-PR. Patients consisted of a total of 134 program completers (72 males, 62 females; mean age = 67.8 years). Significant improvements in functional performance with regard to 6MWT scores were observed across all groups postintervention (P < .05). The Present group, in both the anxiety and depression domains, failed to reach a minimally clinically important difference postintervention. The Probable and Present groups achieved a significant improvement in CAT scores postintervention (P < .05). This study showed that symptoms of anxiety and depression in people with CRDs were significantly related to lower exercise tolerance levels and higher levels of disease impact. People with increased levels of anxiety and depression have the potential to significantly improve disease impact outcomes post-PR. The results demonstrated that the detection and treatment of anxiety and depression symptoms in people with CRDs are likely to be clinically important.

  7. Continuous, high-resolution spatial mapping of water isotopes in oceanic environment using a CRDS analyzer combined with a continuous water sampler.

    NASA Astrophysics Data System (ADS)

    Kim-Hak, David; Huang, Kuan; Winkler, Renato

    2016-04-01

    The recent advancements of the laser-based technology -in particular Cavity Ring Down Spectroscopy, CRDS- gave birth to a new generation of water stable isotope analyzers that are user-friendly, compact and field deployable providing in-situ measurements. Furthermore, with last year's launch of the Continuous Water Sampler front-end, CWS, the analyzer system added two additional dimensions to liquid water measurements: real-time and continuous. These features enable the user to construct high resolution water isotope data sets through time and space. Campaigns on the Sacramento-San Joaquin River Delta with the US Geological Survey where the CWS-CRDS system was deployed onto a boat to spatially map sections of the delta, validated the CWS performance and demonstrated its durability on brackish water. The next step for the CWS is to explore oceanic applications with seawater. Early in-house laboratory experiments showed stable performance with brine waters (3% concentration). For the field experiment, we have collaborated with the China State Oceanic Administration to deploy the CWS-CRDS in oceanic environments on cruises along the costal China and Antarctic. Here, we present the results of the analysis collected onboard and compared them with discrete sampling measurements. The long-term test has also allowed us to assess the durability and expected lifetime of the CWS membrane and to recommend the proper maintenance procedure for optimum performance under oceanic conditions.

  8. Continuous, high-resolution spatial mapping of water isotopes in oceanic environment using a CRDS analyzer combined with a continuous water sampler.

    NASA Astrophysics Data System (ADS)

    Kim-Hak, D.; Huang, K.

    2016-02-01

    The recent advancements of the laser-based technology -in particular Cavity Ring Down Spectroscopy, CRDS- gave birth to a new generation of water stable isotope analyzers that are user-friendly, compact and field deployable providing in-situ measurements. Furthermore, with last year's launch of the Continuous Water Sampler front-end, CWS, the analyzer system added two additional dimensions to liquid water measurements: real-time and continuous. These features enable the user to construct high resolution water isotope data sets through time and space. Campaigns on the Sacramento-San Joaquin River Delta with the US Geological Survey where the CWS-CRDS system was deployed onto a boat to spatially map sections of the delta, validated the CWS performance and demonstrated its durability on brackish water. The next step for the CWS is to explore oceanic applications with seawater. Early in-house laboratory experiments showed stable performance with brine waters (3% concentration). For the field experiment, we have collaborated with the China State Oceanic Administration to deploy the CWS-CRDS in oceanic environments on cruises along the costal China and Antarctic. Here, we present the results of the analysis collected onboard and compared them with discrete sampling measurements. The long-term test has also allowed us to assess the durability and expected lifetime of the CWS membrane and to recommend the proper maintenance procedure for optimum performance under oceanic conditions.

  9. Nucleic acid is a novel ligand for innate, immune pattern recognition collectins surfactant proteins A and D and mannose-binding lectin.

    PubMed

    Palaniyar, Nades; Nadesalingam, Jeya; Clark, Howard; Shih, Michael J; Dodds, Alister W; Reid, Kenneth B M

    2004-07-30

    Collectins are a family of innate immune proteins that contain fibrillar collagen-like regions and globular carbohydrate recognition domains (CRDs). The CRDs of these proteins recognize various microbial surface-specific carbohydrate patterns, particularly hexoses. We hypothesized that collectins, such as pulmonary surfactant proteins (SPs) SP-A and SP-D and serum protein mannose-binding lectin, could recognize nucleic acids, pentose-based anionic phosphate polymers. Here we show that collectins bind DNA from a variety of origins, including bacteria, mice, and synthetic oligonucleotides. Pentoses, such as arabinose, ribose, and deoxyribose, inhibit the interaction between SP-D and mannan, one of the well-studied hexose ligands for SP-D, and biologically relevant d-forms of the pentoses are better competitors than the l-forms. In addition, DNA and RNA polymer-related compounds, such as nucleotide diphosphates and triphosphates, also inhibit the carbohydrate binding ability of SP-D, or approximately 60 kDa trimeric recombinant fragments of SP-D that are composed of the alpha-helical coiled-coil neck region and three CRDs (SP-D(n/CRD)) or SP-D(n/CRD) with eight GXY repeats (SPD(GXY)(8)(n/CRD)). Direct binding and competition studies suggest that collectins bind nucleic acid via their CRDs as well as by their collagen-like regions, and that SP-D binds DNA more effectively than do SP-A and mannose-binding lectin at physiological salt conditions. Furthermore, the SP-D(GXY)(8)(n/CRD) fragments co-localize with DNA, and the protein competes the interaction between propidium iodide, a DNA-binding dye, and apoptotic cells. In conclusion, we show that collectins are a new class of proteins that bind free DNA and the DNA present on apoptotic cells by both their globular CRDs and collagen-like regions. Collectins may therefore play an important role in decreasing the inflammation caused by DNA in lungs and other tissues.

  10. Analog detection for cavity lifetime spectroscopy

    DOEpatents

    Zare, Richard N.; Harb, Charles C.; Paldus, Barbara A.; Spence, Thomas G.

    2001-05-15

    An analog detection system for determining a ring-down rate or decay rate 1/.tau. of an exponentially decaying ring-down beam issuing from a lifetime or ring-down cavity during a ring-down phase. Alternatively, the analog detection system determines a build-up rate of an exponentially growing beam issuing from the cavity during a ring-up phase. The analog system can be employed in continuous wave cavity ring-down spectroscopy (CW CRDS) and pulsed CRDS (P CRDS) arrangements utilizing any type of ring-down cavity including ring-cavities and linear cavities.

  11. Analog detection for cavity lifetime spectroscopy

    DOEpatents

    Zare, Richard N.; Harb, Charles C.; Paldus, Barbara A.; Spence, Thomas G.

    2003-01-01

    An analog detection system for determining a ring-down rate or decay rate 1/.tau. of an exponentially decaying ring-down beam issuing from a lifetime or ring-down cavity during a ring-down phase. Alternatively, the analog detection system determines a build-up rate of an exponentially growing beam issuing from the cavity during a ring-up phase. The analog system can be employed in continuous wave cavity ring-down spectroscopy (CW CRDS) and pulsed CRDS (P CRDS) arrangements utilizing any type of ring-down cavity including ring-cavities and linear cavities.

  12. Long-term greenhouse gas measurements from aircraft

    NASA Astrophysics Data System (ADS)

    Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.

    2013-03-01

    In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. Flights typically last 8 h and cover a large area, traveling from Kodiak up to Barrow, Alaska, with altitude profiles near the coast and in the interior. NOAA instrumentation on each flight includes a flask sampling system, a continuous cavity ring-down spectroscopy (CRDS) carbon dioxide (CO2)/methane (CH4)/carbon monoxide (CO)/water vapor (H2O) analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction and present an assessment of analyzer performance over a three-year period. Overall analytical uncertainty of CRDS measurements in 2011 is estimated to be 0.15 ppm, 1.4 ppb, and 5 ppb for CO2, CH4, and CO, respectively, considering short-term precision, calibration uncertainties, and water vapor correction uncertainty. The stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 4 ppb for CO2, CH4, and CO, respectively, based on differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. We conclude that the uncertainty reported for our measurements would not be significantly affected if the measurements were made without in-flight calibrations, provided ground calibrations and testing were performed regularly. Comparisons between in situ CRDS measurements and flask measurements are consistent with expected measurement uncertainties for CH4 and CO, but differences are larger than expected for CO2. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving the observed flask versus in situ CO2 differences rather than the CRDS measurements.

  13. A Novel Method for Analysis of Dissolved Inorganic Carbon Concentration and δ13C by Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Smith, E.; Gonneea, M. E.; Boze, L. G.; Casso, M.; Pohlman, J.

    2017-12-01

    Dissolved inorganic carbon (DIC) is the largest pool of carbon in the oceans and is where about half of anthropogenic carbon dioxide (CO2) emissions are being sequestered. Determining the concentration and stable carbon isotopic content (δ13C) of DIC allows us to delineate carbon sources that contribute to marine DIC. A simple and reliable method for measuring DIC concentration and δ13C can be used to apportion contributions from external sources and identify effects from biogeochemical reactions that contribute or remove DIC. The U.S. Geological Survey has developed a discrete sample analysis module (DSAM) that interfaces to a Picarro G-2201i cavity ring-down spectrometer (CRDS, Picarro Inc.) to analyze CO2 and methane concentrations and δ13C from discrete gas samples. In this study, we adapted the USGS DSAM-CRDS analysis system to include an AutoMate prep device (Automate FX, Inc.) for analysis of DIC concentration and δ13C from aqueous samples. The Automate prep device was modified to deliver CO2 extracted from DIC to the DSAM, which conditions and transfers the gas to the CRDS. LabVIEW software (National Instruments) triggers the Automate Prep device, controls the DSAM and collects data from the CRDS. CO2 mass concentration data are obtained by numerical integration of the CO2 volumetric concentrations output by the CRDS and subsequent comparison to standard materials. CO2 carbon isotope values from the CRDS (iCO2) are converted to δ13C values using a slope and offset correction calibration procedure. The system design and operation was optimized using sodium bicarbonate (NaHCO3) standards and a certified reference material. Surface water and pore water samples collected from Sage Lot Pond, a salt marsh in Cape Cod MA, have been analyzed for concentration by coulometry and δ13C by isotope ratio mass spectrometry and will be used to validate the DIC-DSAM-CRDS method for field applications.

  14. Continuous Wave Ring-Down Spectroscopy Diagnostic for Measuring Argon Ion and Neutral Velocity Distribution Functions in a Helicon Plasma

    NASA Astrophysics Data System (ADS)

    McCarren, Dustin; Vandervort, Robert; Soderholm, Mark; Carr, Jerry, Jr.; Galante, Matthew; Magee, Richard; Scime, Earl

    2013-10-01

    Cavity Ring-Down Spectroscopy CRDS is a proven, ultra-sensitive, cavity enhanced absorption spectroscopy technique. When combined with a continuous wavelength (CW) diode laser that has a sufficiently narrow line width, the Doppler broadened absorption line, i.e., the velocity distribution functions (IVDFs), can be measured. Measurements of IVDFS can be made using established techniques, such as laser induced fluorescence (LIF). However, LIF suffers from the requirement that the initial state of the LIF sequence have a substantial density. This usually limits LIF to ions and atoms with large metastable state densities for the given plasma conditions. CW-CRDS is considerably more sensitive than LIF and can potentially be applied to much lower density populations of ion and atom states. In this work we present ongoing measurements of the CW-CRDS diagnostic and discuss the technical challenges of using CW-CRDS to make measurements in a helicon plasma.

  15. Measuring 13 C-enriched CO2 in air with a cavity ring-down spectroscopy gas analyser: Evaluation and calibration.

    PubMed

    Dickinson, Dane; Bodé, Samuel; Boeckx, Pascal

    2017-11-30

    Cavity ring-down spectroscopy (CRDS) is becoming increasingly popular for δ 13 C-CO 2 analysis of air. However, little is known about the effect of high 13 C abundances on the performance of CRDS. Overlap between 12 CO 2 and 13 CO 2 spectral lines may adversely affect isotopic-CO 2 CRDS measurements of 13 C-enriched samples. Resolving this issue is important so that CRDS analysers can be used in CO 2 flux studies involving 13 C-labelled tracers. We tested a Picarro G2131-i CRDS isotopic-CO 2 gas analyser with specialty gravimetric standards of widely varying 13 C abundance (from natural to 20.1 atom%) and CO 2 mole fraction (xCO 2 : <0.1 to 2116 ppm) in synthetic air. The presence of spectroscopic interference between 12 CO 2 and 13 CO 2 bands was assessed by analysing errors in measurements of the standards. A multi-component calibration strategy was adopted, incorporating isotope ratio and mole fraction data to ensure accuracy and consistency in corrected values of δ 13 C-CO 2 , x 12 CO 2 , and x 13 CO 2 . CRDS measurements of x 13 CO 2 were found to be accurate throughout the tested range (<0.005 to 100 ppm). On the other hand, spectral cross-talk in x 12 CO 2 measurements of standards containing elevated levels of 13 CO 2 led to inaccuracy in x 12 CO 2 , total-xCO 2 (x 12 CO 2  + x 13 CO 2 ), and δ 13 C-CO 2 data. An empirical relationship for x 12 CO 2 measurements that incorporated the 13 C/ 12 C isotope ratio (i.e. 13 CO 2 / 12 CO 2 , RCO2) as a secondary (non-linear) variable was found to compensate for the perturbations, and enabled accurate instrument calibration for all CO 2 compositions covered by our standard gases. 13 C-enrichement in CO 2 leads to minor errors in CRDS measurements of x 12 CO 2 . We propose an empirical correction for measurements of 13 C-enriched CO 2 in air by CRDS instruments such as the Picarro G2131-i. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Rayleigh scattering cross-section measurements of nitrogen, argon, oxygen and air

    NASA Astrophysics Data System (ADS)

    Thalman, Ryan; Zarzana, Kyle J.; Tolbert, Margaret A.; Volkamer, Rainer

    2014-11-01

    Knowledge about Rayleigh scattering cross sections is relevant to predictions about radiative transfer in the atmosphere, and needed to calibrate the reflectivity of mirrors that are used in high-finesse optical cavities to measure atmospheric trace gases and aerosols. In this work we have measured the absolute Rayleigh scattering cross-section of nitrogen at 405.8 and 532.2 nm using cavity ring-down spectroscopy (CRDS). Further, multi-spectral measurements of the scattering cross-sections of argon, oxygen and air are presented relative to that of nitrogen from 350 to 660 nm using Broadband Cavity Enhanced Spectroscopy (BBCES). The reported measurements agree with refractive index based theory within 0.2±0.4%, and have an absolute accuracy of better than 1.3%. Our measurements expand the spectral range over which Rayleigh scattering cross section measurements of argon, oxygen and air are available at near-ultraviolet wavelengths. The expressions used to represent the Rayleigh scattering cross-section in the literature are evaluated to assess how uncertainties affect quantities measured by cavity enhanced absorption spectroscopic (CEAS) techniques. We conclude that Rayleigh scattering cross sections calculated from theory provide accurate data within very low error bounds, and are suited well to calibrate CEAS measurements of atmospheric trace gases and aerosols.

  17. Cavity ring down spectrometry for disease diagnostics using exhaled air

    NASA Astrophysics Data System (ADS)

    Revalde, G.; Grundšteins, K.; Alnis, J.; Skudra, A.

    2017-12-01

    In this paper we report the current stage of the development of a cavity ring-down spectrometer (CRDS) system using exhaled human breath analysis for the diagnostics of different diseases like diabetes and later lung cancer. The portable CRDS system is made in ultraviolet spectral region using Nd:Yag laser 266 nm pulsed light. Calibration of the CRDS system was performed using generated samples by KinTek automated permeation tube system and self-prepared mixtures with known concentration of benzene and acetone in air. First experiments showed that the limits of detection for benzene and acetone are several tens of ppb.

  18. Characterizing Interferences in an NOy Thermal Dissociation Inlet

    NASA Astrophysics Data System (ADS)

    Womack, C.; Veres, P. R.; Brock, C. A.; Neuman, J. A.; Eilerman, S. J.; Zarzana, K. J.; Dube, W. P.; Wild, R. J.; Wooldridge, P. J.; Cohen, R. C.; Brown, S. S.

    2016-12-01

    Nitrogen oxides (NOx = NO and NO2) are emitted into the troposphere by various anthropogenic and natural sources, and contribute to increased levels of ambient ozone. Reactive nitrogen species (NOy), which include nitric acid, peroxy acetyl and organic nitrates, and other species, serve as reservoirs and sinks for NOx, thus influencing O3 production. Their detection is therefore critical to understanding ozone chemistry. However, accurate measurements of NOy have proven to be difficult to obtain, and measurements of total NOy sometimes do not agree with the sum of measurements of its individual components. In recent years, quartz thermal dissociation (TD) inlets have been used to thermally convert all NOy species to NO2, followed by detection by techniques such as laser induced fluorescence (LIF) or cavity ringdown spectroscopy (CRDS). Here we discuss recent work in characterizing the NOy channel of our four-channel TD-CRDS instrument. In particular, we have examined the thermal conversion efficiency of several representative NOy species under a range of experimental conditions. We find that under certain conditions, the conversion efficiency is sensitive to inlet residence time and to the concentration of other trace gases found in ambient sampling, such as ozone. We also report the thermal dissociation curves of N2O5 and ammonium nitrate aerosol, and discuss the interferences observed when ammonia and ozone are co-sampled in the inlet.

  19. Analysis of δ18O and δD values of environmental waters at high temporal and spatial resolution by continuous diffusion sampling cavity ring-down spectrometry

    NASA Astrophysics Data System (ADS)

    Munksgaard, Niels; Bass, Adrian; Wurster, Chris; Bird, Michael

    2013-04-01

    A novel sampling device utilises diffusion through porous PTFE tubing to deliver water vapour continuously from a liquid water source for analysis of δ18O and δD values by Cavity Ring-Down Spectrometry (CRDS). Comparison of isotopic data for a range of water samples analysed by Diffusion Sampling-CRDS (DS-CRDS) and Isotope Ratio Mass Spectrometry (IRMS) shows significant linear correlations between the two methods allowing for accurate standardisation of DS-CRDS data. The internal precision for an integration period of 3 min (standard deviation = 0.1 ‰ and 0.3 ‰ for δ18O and δD values, respectively) is similar to analysis of water by injection/evaporation CRDS of discrete water samples. The isotopic effects of variable air and water temperature, water vapour concentration and water pumping rate were found to be either negligible or correctable by analysis of water standards. Separation of the analysed water vapour from non-volatile dissolved and particulate contaminants in the liquid sample minimises interferences associated with CRDS analyses of many aqueous samples. Coupling of the DS-CRDS instrument to an auto sampler enables rapid analysis (10 min) of discrete water samples. The DS-CRDS system was used in the first continuous shipboard measurement of δ18O and δD of water. Combined with continuous salinity recordings, a data set of nearly 6,000 isotope measurements was made at 30-s intervals during a 3-day voyage through the Great Barrier Reef Lagoon. Precise identification of river plumes within the Great Barrier Reef Lagoon was possible because unique δ18O/δD-salinity relationships of individual plumes were measured at high spatial and temporal resolution. Continuous shipboard measurement of δ18O/δD values by DS-CRDS provides additional discriminatory power for assessing water mass formation processes and histories at a small fraction of the cost of traditional isotope analysis of discrete samples. In a second application of DS-CRDS, continuous real-time analysis, at 30-s intervals, of precipitation at an Australian tropical location revealed extreme and rapidly changing δ18O and δD values related to variations in moisture source areas, transport paths and precipitation histories. The range of δ18O (-19.6 ‰ to +2.6 ‰) and δD (-140 ‰ to +13 ‰) values from almost 6,000 measurements of nine rain events over 15 days during an 8-month period at a single location was comparable with the range measured in 1532 monthly samples from all seven Australian Global Network of Isotopes in Precipitation stations from 1962 to 2002. Extreme variations in δ18O (-8.7 ‰ to -19.6 ‰) and δD (-54 ‰ to -140 ‰) were recorded within a single 4-h period. Real-time stable isotope monitoring of environmental waters at high temporal and spatial resolution enables new and powerful tracer applications in climatology, hydrology, eco-physiology and palaeo-climatology.

  20. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2012-09-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near infrared region (∼1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs new spectroscopic analysis (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  1. Clinical results from low-level laser therapy in patients with autosomal dominant cone-rod dystrophy

    NASA Astrophysics Data System (ADS)

    Koev, K.; Avramov, L.; Borissova, E.

    2018-03-01

    The objective of this study is to examine long-term effects of low-level laser therapy (LLLT) in patients with autosomal dominant cone-rod dystrophy (CRDs). A He-Ne Laser with continuous emission at 633 nm (01 mW/cm2) was used on five patients with autosomal dominant pedigree of Romani origin with non-syndromic CRDs. The laser radiation was applied transpupillary to the macula six times for three minutes every other day. The experiment was conducted for a period of three years. The clinical evaluation included best corrected visual acuity determination, funduscopy, Humphrey perimetry, Farnsworth Hue-28 color testing, fluorescein angiography, and full-field electroretinogram (ERG). All affected individuals presented reduced visual acuity (0.01 – 0.4) and photophobia. The funduscopic examination and fluorescein angiography revealed advanced changes including bone spicule-like pigment deposits in the midperiphery and the macular area, along with retinal atrophy, narrowing of the vessels, and waxy optic discs. The visual fields demonstrated central scotoma. The electrophysiologic examination of the patients detected an abnormal cone-rod ERG (20 – 30 μV) with photopic amplitudes more markedly reduced than the scotopic. Flicker responses were missing and Farnsworth Hue-28 test found protanopia. There was a statistically significant increase in the visual acuity (p<0.001, end of study versus baseline) for CRDs patients for the period of three years after the treatment with LLLT. Following the LLLT, the central absolute scotoma in CRDs was reduced, as was the prevalence of metamorphopsia in CRDs. This study shows that LLLT may prove be a novel long-lasting therapeutic option for both forms of CRDs. It is a highly effective treatment resulting in a long-term improvement of the visual acuity.

  2. Partial cordierite breakdown during post-seismic recovery: the significance of plastic deformation for cation diffusion and metamorphic equilibrium

    NASA Astrophysics Data System (ADS)

    Büttner, Steffen; Costin, Gelu

    2010-05-01

    Brittle intra-crystal fracturing occurred during a microseismic event in migmatites of the Ordovician Sierras Pampeanas (NW Argentina), forming micro-shear zones and brittle fragments in cordierite. The seismic event occurred at amphibolite facies P-T conditions under high strain rates (≥ 10-7 s-1). During post-seismic recovery and coarsening of crystal fragments, primary cordierite (XMg=0.65) underwent partial breakdown along the deformation zone, forming a secondary mineral assemblage in an alteration zone along grain boundaries of coarsened crystal fragments. The secondary assemblage is restricted to the recovery zone. The breakdown of primary cordierite (CrdP) is accompanied by the formation of secondary sillimanite, magnetite, staurolite (XMg=0.24, ~0.5 wt% ZnO), quartz, and secondary cordierite (CrdS; XMg=0.70-0.80). CrdS, volumetrically the most important secondary phase, forms by diffusion of Mg and Fe, altering CrdP by Fe loss and uptake of Mg. All other secondary phases form by nucleation. Two simultaneous cordierite breakdown reactions have been balanced using CSpace 1.01: 100 CrdP (XMg 0.65) = 21.8 Sil +12.8 Mag + 33.5 Qtz + 5.6 H2O + 89.1 CrdS (XMg 0.75) 100 CrdP (XMg0.65) = 8.1 Mag + 53.6 Qtz + 4.5 H2O + 8.1 St (XMg0.24) + 83.3 CrdS (XMg 0.75) The bulk chemical major element composition of the alteration zone is nearly identical to the composition of primary cordierite, suggesting that elemental exchange between the alteration zone and the cordierite matrix is limited. However, minor fluid influx, supplying Zn, K, Si, and O is indicated by the composition of staurolite, minor formation of biotite and quartz, and by the oxidation of Fe2+ within the alteration zone. The modal composition of the alteration zone has been determined by point counting, which yields similar results like CSpace results (converted into vol%), and MODAN calculations, which calculates modes based on the average alteration zone composition, and the compositions of secondary phases. The average modal composition of the alteration zone is: 2.3 Sil + 2.0 Mag + 4.3 Qtz + 3.9 St+ 87.5 CrdS (vol%) Thermodynamic modelling of primary cordierite breakdown using Theriak Domino shows that the observed breakdown is possible only in a small P -T window around P =450 MPa and T =555 ° C, which is in good agreement with the retrograde P - T path of the Sierra de Quilmes migmatites. Modes calculated using Theriak Domino are similar to results using descriptive methods (point counting), or methods based on chemistry and petrography (MODAN, CSpace). Since modes predicted on the assumption of petrological equilibrium are close to the observed modes, the breakdown reaction seen in the alteration zone most likely represents conditions of, or close to, thermodynamic equilibrium. The formation of the secondary mineral assemblage in the alteration zone depends upon the efficient supply of cations, essentially Si, Al, Fe and Mg. The bulk composition of new secondary minerals (Qtz, St, Mag, Sil) is enriched in Fe compared to CrdP, whereas CrdS is Fe depleted. The provision of Si and Al required for Sil, Qtz, and St can be assigned to partial cordierite breakdown. The excess Fe needed for Mag and St, and the removal of surplus Mg from CrdP breakdown, depends on Fe-Mg diffusion within CrdS. Since CrdS forms exclusively in the post-seismic recovery zone, we interpret dislocation creep, and hence cation diffusion related to plastic deformation, as the key process for the formation of reaction products reflecting thermodynamic equilibrium.

  3. Continuous-Wave Cavity Ring-Down Spectroscopy in a Pulsed Uniform Supersonic Flow

    NASA Astrophysics Data System (ADS)

    Thawoos, Shameemah; Suas-David, Nicolas; Suits, Arthur

    2017-06-01

    We introduce a new approach that couples a pulsed uniform supersonic flow with high sensitivity continuous wave cavity ringdown spectroscopy (UF-CRDS) operated in the near infrared (NIR). This combination is related to the CRESU technique developed in France and used for many years to study reaction kinetics at low temperature, and to the microwave based chirped-pulse uniform supersonic flow spectrometer (CPUF) developed in our group which has successfully demonstrated the use of pulsed uniform supersonic flow to probe reaction dynamics at temperatures as low as 22 K. CRDS operated with NIR permits access to the first overtones of C-H and O-H stretching/bending which, in combination with its extraordinary sensitivity opens new experiments complementary to the CPUF technique. The UF-CRDS apparatus (Figure) utilizes the pulsed uniform flow produced by means of a piezo-electric stack valve in combination with a Laval nozzle. At present, two machined aluminum Laval nozzles designed for carrier gases Ar and He generate flows with a temperature of approximately 25 K and pressure around 0.15 mbar. This flow is probed by an external cavity diode laser in the NIR (1280-1380 nm). Laval nozzles designed using a newly developed MATLAB-based program will be used in the future. A detailed illustration of the novel UF-CRDS instrumentation and its performance will be presented along with future directions and applications. I. Sims, J. L. Queffelec, A. Defrance, C. Rebrion-Rowe, D. Travers, P. Bocherel, B. Rowe, I. W. Smith, J. Chem. Phys. 100, 4229-4241, (1994). C. Abeysekera, B. Joalland, N. Ariyasingha, L. N. Zack, I. R. Sims, R. W. Field, A. G. Suits, J. Phys. Chem. Lett. 6, 1599-1604, (2015). N. Suas-David, T. Vanfleteren, T. Foldes, S. Kassi, R. Georges, M. Herman, J. Phys. Chem.A, 119, 10022-10034, (2015). C. Abeysekera, B. Joalland, Y. Shi, A. Kamasah, J. M. Oldham, A. G. Suits, Rev. Sci. Instrum. 85, 116107, (2014).

  4. Water stable isotope measurements of Antarctic samples by means of IRMS and WS-CRDS techniques

    NASA Astrophysics Data System (ADS)

    Michelini, Marzia; Bonazza, Mattia; Braida, Martina; Flora, Onelio; Dreossi, Giuliano; Stenni, Barbara

    2010-05-01

    In the last years in the scientific community there has been an increasing interest for the application of stable isotope techniques to several environmental problems such as drinking water safeguarding, groundwater management, climate change, soils and paleoclimate studies etc. For example, the water stable isotopes, being natural tracers of the hydrological cycle, have been extensively used as tools to characterize regional aquifers and to reconstruct past temperature changes from polar ice cores. Here the need for improvements in analytical techniques: the high request for information calls for technologies that can offer a great quantity of analyses in short times and with low costs. Furthermore, sometimes it is difficult to obtain big amount of samples (as is the case for Antarctic ice cores or interstitial water) preventing the possibility to replicate the analyses. Here, we present oxygen and hydrogen measurements performed on water samples covering a big range of isotopic values (from very negative antarctic precipitation to mid-latitude precipitation values) carried out with both the conventional Isotope Ratio Mass Spectrometry (IRMS) technique and with a new method based on laser absorption techniques, the Wavelenght Scanned Cavity Ringdown Spectroscopy (WS-CRDS). This study is focusing on improving the precision of the measurements carried out with WS-CRDS in order to extensively apply this method to Antarctic ice core paleoclimate studies. The WS-CRDS is a variation of the CRDS developed in 1988 by O'Keef and Deacon. In CRDS a pulse of light goes through a box with high reflective inner surfaces; when there is no sample in the box the light beam doesn't find any obstacle in its path, but the reflectivity of the walls is not perfect so eventually there will be an absorption of the light beam; when the sample is injected in the box there is absorption and the difference between the time of absorption without and with sample is proportional to the quantity of the sample in the box. In the WS-CRDS the path of laser is longer, producing higher-sensitivity measurements. The instrument is paired with an autosampler and can be used without it and the vaporizer to analyze directly the isotopic composition of the water vapour in the atmosphere. In addition, the instrument can be moved from the laboratory and also used for outdoor measurements. The more important improvements over traditional IRMS techniques are that WS-CRDS needs less sample in order to perform the analysis (<2 ul vs. 3/5 ml); that it doesn't need manipulation of the sample (like the gas/water equilibration techniques) and the analyses are faster. Coversely, memory effects may affect the measurements so there is the need to increase the number of injection to have a high precision measurement. The laboratory of Isotope Geochemistry of the Department of Geosciences has recently acquired a WS-CRDS system from PICARRO. The isotopic data obtained with this new method have been compared with the ones obtained by means of IRMS methods. An HDO device coupled with a Thermo Finnigan Delta Plus Advantage mass spectrometer has been used, using the well know CO2 and H2/water equilibration technique. At the moment of the writing of the abstract the mean difference between the values obtained using PICARRO and using the traditional IRMS method is of the order of 0.1 per mil for the ratio 18O/16O and 1.00 per mil for the ratio D/H, but further measurements are currently underway. O'Keef A., Deacon D.A.G., 1988. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources, Rev. Sci. Instrum., 59, 2544.

  5. Assessment of recent advances in measurement techniques for atmospheric carbon dioxide and methane observations

    NASA Astrophysics Data System (ADS)

    Zellweger, Christoph; Emmenegger, Lukas; Firdaus, Mohd; Hatakka, Juha; Heimann, Martin; Kozlova, Elena; Spain, T. Gerard; Steinbacher, Martin; van der Schoot, Marcel V.; Buchmann, Brigitte

    2016-09-01

    Until recently, atmospheric carbon dioxide (CO2) and methane (CH4) measurements were made almost exclusively using nondispersive infrared (NDIR) absorption and gas chromatography with flame ionisation detection (GC/FID) techniques, respectively. Recently, commercially available instruments based on spectroscopic techniques such as cavity ring-down spectroscopy (CRDS), off-axis integrated cavity output spectroscopy (OA-ICOS) and Fourier transform infrared (FTIR) spectroscopy have become more widely available and affordable. This resulted in a widespread use of these techniques at many measurement stations. This paper is focused on the comparison between a CRDS "travelling instrument" that has been used during performance audits within the Global Atmosphere Watch (GAW) programme of the World Meteorological Organization (WMO) with instruments incorporating other, more traditional techniques for measuring CO2 and CH4 (NDIR and GC/FID). We demonstrate that CRDS instruments and likely other spectroscopic techniques are suitable for WMO/GAW stations and allow a smooth continuation of historic CO2 and CH4 time series. Moreover, the analysis of the audit results indicates that the spectroscopic techniques have a number of advantages over the traditional methods which will lead to the improved accuracy of atmospheric CO2 and CH4 measurements.

  6. Development of alternative plasma sources for cavity ring-down measurements of mercury.

    PubMed

    Duan, Yixiang; Wang, Chuji; Scherrer, Susan T; Winstead, Christopher B

    2005-08-01

    We have been exploring innovative technologies for elemental and hyperfine structure measurements using cavity ring-down spectroscopy (CRDS) combined with various plasma sources. A laboratory CRDS system utilizing a tunable dye laser is employed in this work to demonstrate the feasibility of the technology. An in-house fabricated sampling system is used to generate aerosols from solution samples and introduce the aerosols into the plasma source. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Several microwave plasma discharge devices are tested for mercury CRDS measurement. Various discharge tubes have been designed and tested to reduce background interference and increase the sample path length while still controlling turbulence generated from the plasma gas flow. Significant background reduction has been achieved with the implementation of the newly designed tube-shaped plasma devices, which has resulted in a detection limit of 0.4 ng/mL for mercury with the plasma source CRDS. The calibration curves obtained in this work readily show that linearity over 2 orders of magnitude can be obtained with plasma-CRDS for mercury detection. In this work, the hyperfine structure of mercury at the experimental plasma temperatures is clearly identified. We expect that plasma source cavity ring-down spectroscopy will provide enhanced capabilities for elemental and isotopic measurements.

  7. Sensitive Spectroscopic Analysis of Biomarkers in Exhaled Breath

    NASA Astrophysics Data System (ADS)

    Bicer, A.; Bounds, J.; Zhu, F.; Kolomenskii, A. A.; Kaya, N.; Aluauee, E.; Amani, M.; Schuessler, H. A.

    2018-06-01

    We have developed a novel optical setup which is based on a high finesse cavity and absorption laser spectroscopy in the near-IR spectral region. In pilot experiments, spectrally resolved absorption measurements of biomarkers in exhaled breath, such as methane and acetone, were carried out using cavity ring-down spectroscopy (CRDS). With a 172-cm-long cavity, an efficient optical path of 132 km was achieved. The CRDS technique is well suited for such measurements due to its high sensitivity and good spectral resolution. The detection limits for methane of 8 ppbv and acetone of 2.1 ppbv with spectral sampling of 0.005 cm-1 were achieved, which allowed to analyze multicomponent gas mixtures and to observe absorption peaks of 12CH4 and 13CH4. Further improvements of the technique have the potential to realize diagnostics of health conditions based on a multicomponent analysis of breath samples.

  8. Continuous Wave Ring-Down Spectroscopy for Velocity Distribution Measurements in Plasma

    NASA Astrophysics Data System (ADS)

    McCarren, Dustin W.

    Cavity Ring-Down Spectroscopy CRDS is a proven, ultra-sensitive, cavity enhanced absorption spectroscopy technique. When combined with a continuous wavelength (CW) diode laser that has a sufficiently narrow line width, the Doppler broadened absorption line, i.e., the velocity distribution functions (VDFs) of the absorbing species, can be measured. Measurements of VDFs can be made using established techniques such as laser induced fluorescence (LIF). However, LIF suffers from the requirement that the initial state of the LIF sequence have a substantial density and that the excitation scheme fluoresces at an easily detectable wavelength. This usually limits LIF to ions and atoms with large metastable state densities for the given plasma conditions. CW-CRDS is considerably more sensitive than LIF and can potentially be applied to much lower density populations of ion and atom states. Also, as a direct absorption technique, CW-CRDS measurements only need to be concerned with the species' absorption wavelength and provide an absolute measure of the line integrated initial state density. Presented in this work are measurements of argon ion and neutral VDFs in a helicon plasma using CW-CRDS and LIF.

  9. Analysis of trace impurities in neon by a customized gas chromatography.

    PubMed

    Yin, Min Kyo; Lim, Jeong Sik; Moon, Dong Min; Lee, Gae Ho; Lee, Jeongsoon

    2016-09-09

    Excimer lasers, widely used in the semiconductor industry, are crucial for analyzing the purity of premix laser gases for the purpose of controlling stable laser output power. In this study, we designed a system for analyzing impurities in pure neon (Ne) base gas by customized GC. Impurities in pure neon (H2 and He), which cannot be analyzed at the sub-μmol/mol level using commercial GC detectors, were analyzed by a customized pulsed-discharge Ne ionization detector (PDNeD) and a pressurized injection thermal conductivity detector using Ne as the carrier gas (Pres. Inj. Ne-TCD). From the results, trace species in Ne were identified with the following detection limits: H2, 0.378μmol/mol; O2, 0.119μmol/mol; CH4, 0.880μmol/mol; CO, 0.263μmol/mol; CO2, 0.162μmol/mol (PDNeD); and He, 0.190μmol/mol (Pres. Inj. Ne-TCD). This PDNeD and pressurized injection Ne-TCD technique thus developed permit the quantification of trace impurities present in high-purity Ne. Copyright © 2016. Published by Elsevier B.V.

  10. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2013-04-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near-infrared region (~1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm and for reported H2O mole fractions between 0-4%. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs improved spectroscopic model functions for CO2, H2O, and CO to fit the raw spectral data (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  11. High-accuracy measurements of N2O concentration and site-specific nitrogen isotopes in small or high concentration samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Arata, C.; Huang, K.

    2014-12-01

    Nitrous oxide (N2O) gas is among the major contributors to global warming and ozone depletion in stratosphere. Quantitative estimate of N­2O production in various pathways and N­2O fluxes across different reservoirs is the key to understanding the role of N­2O in the global change. To achieve this goal, accurate and concurrent measurement of both N2O concentration ([N2O]) and its site-specific isotopic composition (SP-δ15N), namely δ15Nα and δ15Nβ, is desired. Recent developments in Cavity Ring-Down Spectroscopy (CRDS) have enabled high precision measurements of [N2O] and SP-δ15N of a continuous gas flow. However, many N­­2O samples are discrete with limited volume (< 500 ml), and/or high [N2O] (> 2 ppm), and are not suitable for direct measurements by CRDS. Here we present results of a Small Sample Isotope Module 2 (SSIM2) which is coupled to and automatically coordinated with a Picarro isotopic N2O CRDS analyzer to handle and measure high concentration and/or small volume samples. The SSIM2 requires 20 ml of sample per analysis, and transfers the sample to the CRDS for high precision measurement. When the sample injection is < 20 ml, a zero gas is optionally filled to make up the volume. We used the SSIM2 to dilute high [N2O] samples and < 20 ml samples, and tested the effect of dilution on the measured SP-δ15N. In addition, we employed and tested a newly developed double injection method for samples adequate for two 20 ml injections. After the SSIM2 and the CRDS cavity was primed with the first injection, the second injection, which has negligible dilution of the sample, can be accurately measured for both [N2O] and SP-δ15N. Results of these experiments indicate that the precision of SSIM2-CRDS is similar to that of the continuous measurements using the CRDS alone, and that dilution has minimal effect on SP-δ15N, as along as the [N2O] is > 300 ppb after dilution. Overall, the precision of SP-δ15N measured using the SSIM2 is < 0.5 ‰.

  12. Online Compound-Specific δ13C and δD Determinations Using Laser Spectroscopy

    NASA Astrophysics Data System (ADS)

    Saad, N.; Hoffnagle, J.

    2012-04-01

    A unique laser spectroscopic approach for making online high-precision compound-specific isotope analysis (CSIA) of both δ13C and δD of the CO2 and H2O organic combustion products is described. The system consists of a gas chromatograph (GC) for the separation of an organic mixture coupled to a novel micro-fabricated microreactor (MFMR) for the complete combustion of each organic compound into CO2 and H2O and the precise measurements of δ13C in the CO2 gas and δ2H in the H2O vapor from the well established infrared spectrum of both gases, using an isotopic CO2 Cavity Ring-Down Spectroscopy (CRDS) analyzer and an isotopic H2O vapor CRDS analyzer, respectively. Light hydrocarbons are used as our test compounds in this study. The analyses of CH4, C2H6 and C3H8 for δ13C and δ2H values resulted in precisions of SD(δ13C)<1‰ and SD(δ2H)<2‰, respectively. These results were further compared to the gold standard method using Dual Inlet IRMS (DI-IRMS) and showed excellent agreements in isotopic measurements. The preliminary results presented here pave the way for a single CRDS analyzer-based system that simultaneously measures δ13C and δD, is field-deployable, less costly and necessitates less operator expertise than IRMS-based systems.

  13. Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasqualotto, R.; Alfier, A.; Lotto, L.

    2010-10-15

    The rf source test facility SPIDER will test and optimize the source of the 1 MV neutral beam injection systems for ITER. Cavity ring-down spectroscopy (CRDS) will measure the absolute line-of-sight integrated density of negative (H{sup -} and D{sup -}) ions, produced in the extraction region of the source. CRDS takes advantage of the photodetachment process: negative ions are converted to neutral hydrogen atoms by electron stripping through absorption of a photon from a laser. The design of this diagnostic is presented with the corresponding simulation of the expected performance. A prototype operated without plasma has provided CRDS reference signals,more » design validation, and results concerning the signal-to-noise ratio.« less

  14. Low-temperature high-resolution absorption spectrum of 14NH3 in the ν1+ν3 band region (1.51 μm)

    NASA Astrophysics Data System (ADS)

    Földes, T.; Golebiowski, D.; Herman, M.; Softley, T. P.; Di Lonardo, G.; Fusina, L.

    2014-09-01

    Jet-cooled spectra of 14NH3 and 15NH3 in natural abundance were recorded using cavity ring-down (CRDS, 6584-6670 cm-1) and cavity enhanced absorption (CEAS, 6530-6700 cm-1) spectroscopy. Line broadening effects in the CRDS spectrum allowed lines with J″-values between 0 and 3 to be identified. Intensity ratios in 14NH3 between the jet-cooled CRDS and literature room-temperature data from Sung et al. (J. Quant. Spectrosc. Radiat. Transfer, 113 (2012), 1066) further assisted the line assignments. Ground state combination differences were extensively used to support the assignments, providing reliable values for J, K and inversion symmetry of the ground state vibrational levels. CEAS data helped in this respect for the lowest J lines, some of which are saturated in the CRDS spectrum. Further information on a/s doublets arose from the observed spectral structures. Thirty-two transitions of 14NH3 were assigned in this way and a limited but significant number (19) of changes in the assignments results, compared to Sung et al. or to Cacciani et al. (J. Quant. Spectrosc. Radiat. Transfer, 113 (2012), 1084). Sixteen known and 25 new low-J transitions were identified for 15NH3 in the CRDS spectrum but the much scarcer literature information did not allow for any more refined assignment. The present line position measurements improve on literature values published for 15NH3 and on some line positions for 14NH3.

  15. Quantifying Carbon-14 for Biology Using Cavity Ring-Down Spectroscopy.

    PubMed

    McCartt, A Daniel; Ognibene, Ted J; Bench, Graham; Turteltaub, Kenneth W

    2016-09-06

    A cavity ring-down spectroscopy (CRDS) instrument was developed using mature, robust hardware for the measurement of carbon-14 in biological studies. The system was characterized using carbon-14 elevated glucose samples and returned a linear response up to 387 times contemporary carbon-14 concentrations. Carbon-14 free and contemporary carbon-14 samples with varying carbon-13 concentrations were used to assess the method detection limit of approximately one-third contemporary carbon-14 levels. Sources of inaccuracies are presented and discussed, and the capability to measure carbon-14 in biological samples is demonstrated by comparing pharmacokinetics from carbon-14 dosed guinea pigs analyzed by both CRDS and accelerator mass spectrometry. The CRDS approach presented affords easy access to powerful carbon-14 tracer techniques that can characterize complex biochemical systems.

  16. Pressure optimization of an EC-QCL based cavity ring-down spectroscopy instrument for exhaled NO detection

    NASA Astrophysics Data System (ADS)

    Zhou, Sheng; Han, Yanling; Li, Bincheng

    2018-02-01

    Nitric oxide (NO) in exhaled breath has gained increasing interest in recent years mainly driven by the clinical need to monitor inflammatory status in respiratory disorders, such as asthma and other pulmonary conditions. Mid-infrared cavity ring-down spectroscopy (CRDS) using an external cavity, widely tunable continuous-wave quantum cascade laser operating at 5.3 µm was employed for NO detection. The detection pressure was reduced in steps to improve the sensitivity, and the optimal pressure was determined to be 15 kPa based on the fitting residual analysis of measured absorption spectra. A detection limit (1σ, or one time of standard deviation) of 0.41 ppb was experimentally achieved for NO detection in human breath under the optimized condition in a total of 60 s acquisition time (2 s per data point). Diurnal measurement session was conducted for exhaled NO. The experimental results indicated that mid-infrared CRDS technique has great potential for various applications in health diagnosis.

  17. High-precision optical measurements of 13C/12C isotope ratios in organic compounds at natural abundance

    PubMed Central

    Zare, Richard N.; Kuramoto, Douglas S.; Haase, Christa; Tan, Sze M.; Crosson, Eric R.; Saad, Nabil M. R.

    2009-01-01

    A continuous-flow cavity ring-down spectroscopy (CRDS) system integrating a chromatographic separation technique, a catalytic combustor, and an isotopic 13C/12C optical analyzer is described for the isotopic analysis of a mixture of organic compounds. A demonstration of its potential is made for the geochemically important class of short-chain hydrocarbons. The system proved to be linear over a 3-fold injection volume dynamic range with an average precision of 0.95‰ and 0.67‰ for ethane and propane, respectively. The calibrated accuracy for methane, ethane, and propane is within 3‰ of the values determined using isotope ratio mass spectrometry (IRMS), which is the current method of choice for compound-specific isotope analysis. With anticipated improvements, the low-cost, portable, and easy-to-use CRDS-based instrumental setup is poised to evolve into a credible challenge to the high-cost and complex IRMS-based technique. PMID:19564619

  18. Application of acoustic micro-resonators in quartz-enhanced photoacoustic spectroscopy for trace gas analysis

    NASA Astrophysics Data System (ADS)

    Zheng, Huadan; Dong, Lei; Wu, Hongpeng; Yin, Xukun; Xiao, Liantuan; Jia, Suotang; Curl, Robert F.; Tittel, Frank K.

    2018-01-01

    During the past 15 years since the first report of quartz enhanced photoacoustic spectroscopy (QEPAS), QEPAS has become one of the leading optical techniques for trace chemical gas sensing. This paper is a review of the current state-of-the art of QEPAS. QEPAS based spectrophones with different acoustic micro-resonators (AmR) configurations employing both standard quartz tuning forks (QTFs) and custom-made QTFs are summarized and discussed in detail.

  19. Quantifying Carbon-14 for Biology Using Cavity Ring-Down Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCartt, A. Daniel; Ognibene, Ted J.; Bench, Graham

    A cavity ring-down spectroscopy (CRDS) instrument was developed using mature, robust hardware for the measurement of carbon-14 in biological studies. The system was characterized using carbon-14 elevated glucose samples and returned a linear response up to 387 times contemporary carbon-14 concentrations. Carbon-14 free and contemporary carbon-14 samples with varying carbon-13 concentrations were used to assess the method detection limit of approximately one-third contemporary carbon-14 levels. Sources of inaccuracies are presented and discussed, and the capability to measure carbon-14 in biological samples is demonstrated by comparing pharmacokinetics from carbon-14 dosed guinea pigs analyzed by both CRDS and accelerator mass spectrometry. Here,more » the CRDS approach presented affords easy access to powerful carbon-14 tracer techniques that can characterize complex biochemical systems.« less

  20. Quantifying Carbon-14 for Biology Using Cavity Ring-Down Spectroscopy

    DOE PAGES

    McCartt, A. Daniel; Ognibene, Ted J.; Bench, Graham; ...

    2016-07-26

    A cavity ring-down spectroscopy (CRDS) instrument was developed using mature, robust hardware for the measurement of carbon-14 in biological studies. The system was characterized using carbon-14 elevated glucose samples and returned a linear response up to 387 times contemporary carbon-14 concentrations. Carbon-14 free and contemporary carbon-14 samples with varying carbon-13 concentrations were used to assess the method detection limit of approximately one-third contemporary carbon-14 levels. Sources of inaccuracies are presented and discussed, and the capability to measure carbon-14 in biological samples is demonstrated by comparing pharmacokinetics from carbon-14 dosed guinea pigs analyzed by both CRDS and accelerator mass spectrometry. Here,more » the CRDS approach presented affords easy access to powerful carbon-14 tracer techniques that can characterize complex biochemical systems.« less

  1. Novel laser induced photoacoustic spectroscopy for instantaneous trace detection of explosive materials.

    PubMed

    El-Sharkawy, Yasser H; Elbasuney, Sherif

    2017-08-01

    Laser photoacoustic spectroscopy (LPAS) is an attractive technology in terms of simplicity, ruggedness, and overall sensitivity; it detects the time dependent heat generated (thermo-elastic effect) in the target via interaction with pulsed optical radiation. This study reports on novel LPAS technique that offers instant and standoff detection capabilities of trace explosives. Over the current study, light is generated using pulsed Q-switched Nd:YAG laser; the generated photoacoustic response in stimulated explosive material offers signature values that depend on the optical, thermal, and acoustical properties. The generated acoustic waves were captured using piezoelectric transducer as well as novel customized optical sensor with remotely laser interferometer probe. A digital signal processing algorithm was employed to identify explosive material signatures via calculation of characteristic optical properties (absorption coefficient), sound velocity, and frequency response of the generated photoacoustic signal. Customized LPAS technique was employed for instantaneous trace detection of three main different high explosive materials including TNT, RDX, and HMX. The main outcome of this study is that the novel customized optical sensor signals were validated with traditional piezoelectric transducer. Furthermore, the customized optical sensor offered standoff detection capabilities (10cm), fast response, high sensitivity, and enhanced signal to noise ratio. This manuscript shaded the light on the instant detection of trace explosive materials from significant standoffs using novel customized LPAS technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Minicollagen-15, a novel minicollagen isolated from Hydra, forms tubule structures in nematocysts.

    PubMed

    Adamczyk, Patrizia; Meier, Sebastian; Gross, Thomas; Hobmayer, Bert; Grzesiek, Stephan; Bächinger, Hans Peter; Holstein, Thomas W; Ozbek, Suat

    2008-02-29

    Minicollagens constitute a family of unusually short collagen molecules isolated from cnidarians. They are restricted to the nematocyst, a cylindrical explosive organelle serving in defense and capture of prey. The nematocyst capsule contains a long tubule inside of its matrix, which is expelled and everted during an ultrafast discharge process. Here, we report the cloning and characterization of a novel minicollagen in Hydra, designated minicollagen-15 (NCol-15). NCol-15, like NCol-3 and NCol-4, shows deviations from the canonical cysteine pattern in its terminal cysteine-rich domains (CRDs). Minicollagens share common domain architectures with a central collagen sequence flanked by polyproline stretches and short N- and C-terminal CRDs. The CRDs are involved in the formation of a highly resistant cysteine network, which constitutes the basic structure of the nematocyst capsule. Unlike NCol-1, which is part of the capsule wall, NCol-15 is localized to tubules, arguing for a functional differentiation of minicollagens within the nematocyst architecture. NMR analysis of the altered C-terminal CRD of NCol-15 showed a novel disulfide-linked structure within the cysteine-containing region exhibiting similar folding kinetics and stability as the canonical CRDs. Our data provide evidence for evolutionary diversification among minicollagens, which probably facilitated alterations in the morphology of the nematocyst wall and tubule.

  3. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    PubMed

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  4. Following radical pair reactions in solution: a step change in sensitivity using cavity ring-down detection.

    PubMed

    Maeda, Kiminori; Neil, Simon R T; Henbest, Kevin B; Weber, Stefan; Schleicher, Erik; Hore, P J; Mackenzie, Stuart R; Timmel, Christiane R

    2011-11-09

    The study of radical pair intermediates in biological systems has been hampered by the low sensitivity of the optical techniques usually employed to investigate these highly reactive species. Understanding the physical principles governing the spin-selective and magneto-sensitive yields and kinetics of their reactions is essential in identifying the mechanism governing bird migration, and might have significance in the discussion of potential health hazards of electromagnetic radiation. Here, we demonstrate the powerful capabilities of optical cavity-enhanced techniques, such as cavity ring-down spectroscopy (CRDS) in monitoring radical recombination reactions and associated magnetic field effects (MFEs). These include submicrosecond time-resolution, high sensitivity (baseline noise on the order of 10(-6) absorbance units) and small (μL) sample volumes. Combined, we show that these represent significant advantages over the single-pass flash-photolysis techniques conventionally applied. The studies described here focus on photoinduced radical pair reactions involving the protein lysozyme and one of two possible photosensitizers: anthraquinone-2,6-disulphonate and flavin mononucleotide. CRDS-measured MFEs are observed in pump-probe experiments and discussed in terms of the sensitivity gains and sample-volume minimization afforded by CRDS when compared with flash photolysis methods. Finally, CRDS is applied to an in vitro MFE study of intramolecular electron transfer in the DNA-repair enzyme, Escherichia coli photolyase, a protein closely related to cryptochrome which has been proposed to mediate animal magnetoreception.

  5. Prevention and control of chronic chest diseases: National Action Plan for NCD Prevention, Control and Health Promotion in Pakistan.

    PubMed

    Nishtar, Sania; Ahmed, Ashfaq; Kazi, Yawar; Khan, Aslam; Mohamud, Khalif Bile

    2004-12-01

    The National Action Plan for Non-Communicable Disease Prevention, Control and Health Promotion in Pakistan (NAP-NCD) does not include surveillance of Chronic Respiratory Diseases (CRDs) into the integrated NCD surveillance model due to issues with assessing the magnitude of the burden of CRD in general and chronic obstructive pulmonary disease (COPD) in particular, within populations. Tobacco has been used as a proxy for the magnitude of COPD in the population. However, it stresses on the need to develop acceptable criteria for the diagnosis of CRDs and methodologies to monitor CRDs. The CRD component of the NAP-NCD integrates prevention of CRDs with a comprehensive NCD prevention and control framework with specific emphasis on tobacco as a cross-cutting theme. It prioritizes the examination of trends in outdoor air pollution levels and their determinants in order to develop appropriate public health interventions. Other priority areas include research to quantify the magnitude and determinants of chronic lung diseases attributable to indoor air pollution both in the rural and urban areas; the development of appropriate public health strategies to reduce risks in such settings and the integration of guidance on CRD prevention with an NCD behaviour change communication strategy. The cross-cutting theme of environmental pollution and occupational exposure to toxins develops common action areas for CRD and cancer prevention.

  6. Optical re-injection in cavity-enhanced absorption spectroscopy

    PubMed Central

    Leen, J. Brian; O’Keefe, Anthony

    2014-01-01

    Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10−10 cm−1/\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$\\sqrt {{\\rm Hz;}}$\\end{document} Hz ; an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features. PMID:25273701

  7. Stray Light Analysis

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Based on a Small Business Innovation Research contract from the Jet Propulsion Laboratory, TracePro is state-of-the-art interactive software created by Lambda Research Corporation to detect stray light in optical systems. An image can be ruined by incidental light in an optical system. To maintain image excellence from an optical system, stray light must be detected and eliminated. TracePro accounts for absorption, specular reflection and refraction, scattering and aperture diffraction of light. Output from the software consists of spatial irradiance plots and angular radiance plots. Results can be viewed as contour maps or as ray histories in tabular form. TracePro is adept at modeling solids such as lenses, baffles, light pipes, integrating spheres, non-imaging concentrators, and complete illumination systems. The firm's customer base includes Lockheed Martin, Samsung Electronics and other manufacturing, optical, aerospace, and educational companies worldwide.

  8. Expanding the scope and applicability of laser-based spectroscopy to studies of ecohydrology by removing organic contaminants in natural water

    NASA Astrophysics Data System (ADS)

    Dennis, K. J.; Rees-Owen, R. L.; Brooks, P. D.; Carter, J.; Dawson, T. E.

    2014-12-01

    The ability to measure the stable isotopic composition of plant and soil waters, surface waters and ambient atmospheric vapor is essential to understanding an ecosystem's water budget, including how water cycles between the air, plants and the subsurface. With the advent of laser-based spectroscopy, e.g., Cavity Ring-Down Spectroscopy (CRDS), the isotopic analysis of waters has become increasingly cost-effective and prevalent, with comparable precision to conventional isotope ratio mass spectrometry methods. However, early work [1,2] demonstrated that the accuracy of isotopic analysis by laser-absorption techniques could be compromised by the spectral interference from organic compounds, in particular methanol and ethanol [1], which are prevalent in ecologically-derived waters. Here we present results from the Picarro Micro-Combustion Module (MCM), which acts to destructively remove these interfering organic species from the analyzed water vapor stream by oxidizing them to CO2 and H2O. Analyzed samples include simulated plant water solutions, waters doped with varying concentrations of potentially problematic organic compounds, and actual plant water extracts. We find that the median offset between IRMS and a Picarro L2130-i outfitted with a MCM is less than 0.5 ‰ for δ18O and less than 1 ‰ for δD. In parallel to the destruction of organic contaminants, a software tool can also be used to assess the probability of spectral interference. This software performs a statistical analysis of spectral fit parameters, e.g., the shift in the spectral baseline, and compares unknown samples to clean standard waters. In general, the most common primary metabolites present in plant materials include the light organic acids, e.g., benzoic and formic acid. At low concentrations (0.1 and 1%) formic acid does not appear to interfere with the resolved absorption spectra for H2O, HDO and H218O. Similar tests will be conducted for benzoic acid. Conversely, although methanol and ethanol are only present in trace amounts in plants, these alcohols can cause large interferences even at the low concentrations (1% and 0.025% for ethanol and methanol, respectively). Using these results, we will propose when CRDS for ecologically-derived waters functions best. [1] Brand et al. (2009), RCM, 23 [2] West et al. (2010), RCM, 24

  9. Digital micromirror devices in Raman trace detection of explosives

    NASA Astrophysics Data System (ADS)

    Glimtoft, Martin; Svanqvist, Mattias; Ågren, Matilda; Nordberg, Markus; Östmark, Henric

    2016-05-01

    Imaging Raman spectroscopy based on tunable filters is an established technique for detecting single explosives particles at stand-off distances. However, large light losses are inherent in the design due to sequential imaging at different wavelengths, leading to effective transmission often well below 1 %. The use of digital micromirror devices (DMD) and compressive sensing (CS) in imaging Raman explosives trace detection can improve light throughput and add significant flexibility compared to existing systems. DMDs are based on mature microelectronics technology, and are compact, scalable, and can be customized for specific tasks, including new functions not available with current technologies. This paper has been focusing on investigating how a DMD can be used when applying CS-based imaging Raman spectroscopy on stand-off explosives trace detection, and evaluating the performance in terms of light throughput, image reconstruction ability and potential detection limits. This type of setup also gives the possibility to combine imaging Raman with non-spatially resolved fluorescence suppression techniques, such as Kerr gating. The system used consists of a 2nd harmonics Nd:YAG laser for sample excitation, collection optics, DMD, CMOScamera and a spectrometer with ICCD camera for signal gating and detection. Initial results for compressive sensing imaging Raman shows a stable reconstruction procedure even at low signals and in presence of interfering background signal. It is also shown to give increased effective light transmission without sacrificing molecular specificity or area coverage compared to filter based imaging Raman. At the same time it adds flexibility so the setup can be customized for new functionality.

  10. ColorTree: a batch customization tool for phylogenic trees

    PubMed Central

    Chen, Wei-Hua; Lercher, Martin J

    2009-01-01

    Background Genome sequencing projects and comparative genomics studies typically aim to trace the evolutionary history of large gene sets, often requiring human inspection of hundreds of phylogenetic trees. If trees are checked for compatibility with an explicit null hypothesis (e.g., the monophyly of certain groups), this daunting task is greatly facilitated by an appropriate coloring scheme. Findings In this note, we introduce ColorTree, a simple yet powerful batch customization tool for phylogenic trees. Based on pattern matching rules, ColorTree applies a set of customizations to an input tree file, e.g., coloring labels or branches. The customized trees are saved to an output file, which can then be viewed and further edited by Dendroscope (a freely available tree viewer). ColorTree runs on any Perl installation as a stand-alone command line tool, and its application can thus be easily automated. This way, hundreds of phylogenic trees can be customized for easy visual inspection in a matter of minutes. Conclusion ColorTree allows efficient and flexible visual customization of large tree sets through the application of a user-supplied configuration file to multiple tree files. PMID:19646243

  11. ColorTree: a batch customization tool for phylogenic trees.

    PubMed

    Chen, Wei-Hua; Lercher, Martin J

    2009-07-31

    Genome sequencing projects and comparative genomics studies typically aim to trace the evolutionary history of large gene sets, often requiring human inspection of hundreds of phylogenetic trees. If trees are checked for compatibility with an explicit null hypothesis (e.g., the monophyly of certain groups), this daunting task is greatly facilitated by an appropriate coloring scheme. In this note, we introduce ColorTree, a simple yet powerful batch customization tool for phylogenic trees. Based on pattern matching rules, ColorTree applies a set of customizations to an input tree file, e.g., coloring labels or branches. The customized trees are saved to an output file, which can then be viewed and further edited by Dendroscope (a freely available tree viewer). ColorTree runs on any Perl installation as a stand-alone command line tool, and its application can thus be easily automated. This way, hundreds of phylogenic trees can be customized for easy visual inspection in a matter of minutes. ColorTree allows efficient and flexible visual customization of large tree sets through the application of a user-supplied configuration file to multiple tree files.

  12. Effect of the equivalent refractive index on intraocular lens power prediction with ray tracing after myopic laser in situ keratomileusis.

    PubMed

    Canovas, Carmen; van der Mooren, Marrie; Rosén, Robert; Piers, Patricia A; Wang, Li; Koch, Douglas D; Artal, Pablo

    2015-05-01

    To determine the impact of the equivalent refractive index (ERI) on intraocular lens (IOL) power prediction for eyes with previous myopic laser in situ keratomileusis (LASIK) using custom ray tracing. AMO B.V., Groningen, the Netherlands, and the Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. Retrospective data analysis. The ERI was calculated individually from the post-LASIK total corneal power. Two methods to account for the posterior corneal surface were tested; that is, calculation from pre-LASIK data or from post-LASIK data only. Four IOL power predictions were generated using a computer-based ray-tracing technique, including individual ERI results from both calculation methods, a mean ERI over the whole population, and the ERI for normal patients. For each patient, IOL power results calculated from the four predictions as well as those obtained with the Haigis-L were compared with the optimum IOL power calculated after cataract surgery. The study evaluated 25 patients. The mean and range of ERI values determined using post-LASIK data were similar to those determined from pre-LASIK data. Introducing individual or an average ERI in the ray-tracing IOL power calculation procedure resulted in mean IOL power errors that were not significantly different from zero. The ray-tracing procedure that includes an average ERI gave a greater percentage of eyes with an IOL power prediction error within ±0.5 diopter than the Haigis-L (84% versus 52%). For IOL power determination in post-LASIK patients, custom ray tracing including a modified ERI was an accurate procedure that exceeded the current standards for normal eyes. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. A gas chromatograph for quantification of peroxycarboxylic nitric anhydrides calibrated by thermal dissociation cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Tokarek, T. W.; Huo, J. A.; Odame-Ankrah, C. A.; Hammoud, D.; Taha, Y. M.; Osthoff, H. D.

    2014-06-01

    The peroxycarboxylic nitric anhydrides (PANs, molecular formula RC(O)O2NO2) can readily be observed by gas chromatography coupled to electron capture detection (PAN-GC). Calibration of a PAN-GC remains a challenge because the response factors (RF's) differ for each of the PANs and because their synthesis in sufficiently high purity is non-trivial, in particular for PANs containing unsaturated side chains. In this manuscript, a PAN-GC and its calibration using diffusion standards, whose output was quantified by blue diode laser thermal dissociation cavity ring-down spectroscopy (TD-CRDS), are described. The PAN-GC peak areas correlated linearly with total peroxy nitrate (ΣPN) mixing ratios measured by TD-CRDS (r > 0.96). Accurate determination of RF's required the concentrations of PAN impurities in the synthetic standards to be subtracted from ΣPN. The PAN-GC and its TD-CRDS calibration method were deployed during ambient air measurement campaigns in Abbotsford, BC, from 20 July to 5 August, 2012, and during the Fort McMurray Oil Sands Strategic Investigation of Local Sources (FOSSILS) campaign at the AMS13 ground site in Fort McKay, AB, from 10 August to 5 September 2013. For the Abbotsford data set, the PAN-GC mixing ratios were compared and agreed with those determined in parallel by thermal dissociation chemical ionization mass spectrometry (TD-CIMS). Advantages and disadvantages of the PAN measurement techniques used in this work and the utility of TD-CRDS as a PAN-GC calibration method are discussed.

  14. A novel C-type lectin with two CRD domains from Chinese shrimp Fenneropenaeus chinensis functions as a pattern recognition protein.

    PubMed

    Zhang, Xiao-Wen; Xu, Wen-Teng; Wang, Xian-Wei; Mu, Yi; Zhao, Xiao-Fan; Yu, Xiao-Qiang; Wang, Jin-Xing

    2009-05-01

    Lectins are regarded as potential immune recognition proteins. In this study, a novel C-type lectin (Fc-Lec2) was cloned from the hepatopancreas of Chinese shrimp, Fenneropenaeus chinensis. The cDNA of Fc-Lec2 is 1219 bp with an open reading frame (ORF) of 1002 bp that encodes a protein of 333 amino acids. Fc-Lec2 contains a signal peptide and two different carbohydrate recognition domains (CRDs) arranged in tandem. The first CRD contains a QPD (Gln-Pro-Asp) motif that has a predicted binding specificity for galactose and the second CRD contains a EPN (Glu-Pro-Asn) motif for mannose. Fc-Lec2 was constitutively expressed in the hepatopancreas of normal shrimp, and its expression was up-regulated in the hepatopancreas of shrimp challenged with bacteria or viruses. Recombinant mature Fc-Lec2 and its two individual CRDs (CRD1 and 2) did not have hemagglutinating activity against animal red blood cells, but agglutinated some gram-positive and gram-negative bacteria in a calcium-dependent manner. The three recombinant proteins also bound to bacteria in the absence of calcium. Fc-Lec2 seems to have broader specificity and higher affinity for bacteria and polysaccharides (peptidoglycan, lipoteichoic acid and lipopolysaccharide) than each of the two individual CRDs. These data suggest that the two CRDs have synergistic effect, and the intact lectin may be more effective in response to bacterial infection, the Fc-Lec2 performs its pattern recognition function by binding to polysaccharides of pathogen cells.

  15. Diversity in recognition of glycans by F-type lectins and galectins: molecular, structural, and biophysical aspects

    PubMed Central

    Vasta, Gerardo R.; Ahmed, Hafiz; Bianchet, Mario A.; Fernández-Robledo, José A.; Amzel, L. Mario

    2013-01-01

    Although lectins are “hard-wired” in the germline, the presence of tandemly arrayed carbohydrate recognition domains (CRDs), of chimeric structures displaying distinct CRDs, of polymorphic genes resulting in multiple isoforms, and in some cases, of a considerable recognition plasticity of their carbohydrate binding sites, significantly expand the lectin ligand-recognition spectrum and lectin functional diversification. Analysis of structural/functional aspects of galectins and F-lectins—the most recently identified lectin family characterized by a unique CRD sequence motif (a distinctive structural fold) and nominal specificity for l-Fuc—has led to a greater understanding of self/nonself recognition by proteins with tandemly arrayed CRDs. For lectins with a single CRD, however, recognition of self and nonself glycans can only be rationalized in terms of protein oligomerization and ligand clustering and presentation. Spatial and temporal changes in lectin expression, secretion, and local concentrations in extracellular microenvironments, as well as structural diversity and spatial display of their carbohydrate ligands on the host or microbial cell surface, are suggestive of a dynamic interplay of their recognition and effector functions in development and immunity. PMID:22973821

  16. A free-flowing soap film combined with cavity ring-down spectroscopy as a detection system for liquid chromatography.

    PubMed

    Vogelsang, Markus; Welsch, Thomas; Jones, Harold

    2010-05-07

    We have shown that a free-flowing soap film has sufficiently high-quality optical properties to allow it to be used in the cavity of a ring-down spectrometer (CRDS). The flow rates required to maintain a stable soap film were similar to those used in liquid chromatography and thus allowed interfacing with an HPLC system for use as an optical detector. We have investigated the properties of the system in a relevant analytical application. The soap film/CRDS combination was used at 355 nm as a detector for the separation of a mixture of nitroarenes. These compounds play a role in the residue analysis of areas contaminated with explosives and their decomposition products. In spite of the short absorption path length (9 microm) obtained by the soap film, the high-sensitivity of CRDS allowed a limit of detection of 4 x 10(-6) in absorption units (AU) or less than 17 fmol in the detection volume to be achieved. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  17. Development of a multiple gas analyzer using cavity ringdown spectroscopy for use in advanced fire detection.

    PubMed

    Fallows, Eric A; Cleary, Thomas G; Miller, J Houston

    2009-02-01

    A portable cavity ringdown spectroscopy (CRDS) apparatus was used to detect effluents from small test fires in the Fire Emulator/Detector Evaluator (FE/DE) and a small room in the Building Fire and Research Laboratory at the National Institute of Standards and Technology (NIST). The output from two lasers is combined to detect four combustion gases, CO, CO(2), HCN, and C(2)H(2), near simultaneously using CRDS. The goal of this work was to demonstrate the feasibility of using a CRDS sensor as a fire detector. Fire effluents were extracted from several test facilities and measurements of CO, CO(2), HCN, and C(2)H(2) were obtained every 25-30 s. In the FE/DE test, peak concentrations of the gases from smoldering paper were 420 parts in 10(6) (ppm) CO, 1600 ppm CO(2), 530 parts in 10(9) (ppb) HCN, and 440 ppb C(2)H(2). Peak gas concentrations from the small room were 270 ppm CO, 2100 ppm CO(2), and 310 ppb C(2)H(2).

  18. Simultaneous analysis of 17O/16O, 18O/16O and 2H/1H of gypsum hydration water by cavity ring‐down laser spectroscopy

    PubMed Central

    Mather, Ian; Rolfe, James; Evans, Nicholas P.; Herwartz, Daniel; Staubwasser, Michael; Hodell, David A.

    2015-01-01

    Rationale The recent development of cavity ring‐down laser spectroscopy (CRDS) instruments capable of measuring 17O‐excess in water has created new opportunities for studying the hydrologic cycle. Here we apply this new method to studying the triple oxygen (17O/16O, 18O/16O) and hydrogen (2H/1H) isotope ratios of gypsum hydration water (GHW), which can provide information about the conditions under which the mineral formed and subsequent post‐depositional interaction with other fluids. Methods We developed a semi‐automated procedure for extracting GHW by slowly heating the sample to 400°C in vacuo and cryogenically trapping the evolved water. The isotopic composition (δ17O, δ18O and δ2H values) of the GHW is subsequently measured by CRDS. The extraction apparatus allows the dehydration of five samples and one standard simultaneously, thereby increasing the long‐term precision and sample throughput compared with previous methods. The apparatus is also useful for distilling brines prior to isotopic analysis. A direct comparison is made between results of 17O‐excess in GHW obtained by CRDS and fluorination followed by isotope ratio mass spectrometry (IRMS) of O2. Results The long‐term analytical precision of our method of extraction and isotopic analysis of GHW by CRDS is ±0.07‰ for δ17O values, ±0.13‰ for δ18O values and ±0.49‰ for δ2H values (all ±1SD), and ±1.1‰ and ±8 per meg for the deuterium‐excess and 17O‐excess, respectively. Accurate measurement of the 17O‐excess values of GHW, of both synthetic and natural samples, requires the use of a micro‐combustion module (MCM). This accessory removes contaminants (VOCs, H2S, etc.) from the water vapour stream that interfere with the wavelengths used for spectroscopic measurement of water isotopologues. CRDS/MCM and IRMS methods yield similar isotopic results for the analysis of both synthetic and natural gypsum samples within analytical error of the two methods. Conclusions We demonstrate that precise and simultaneous isotopic measurements of δ17O, δ18O and δ2H values, and the derived deuterium‐excess and 17O‐excess, can be obtained from GHW and brines using a new extraction apparatus and subsequent measurement by CRDS. This method provides new opportunities for the application of water isotope tracers in hydrologic and paleoclimatologic research. © 2015 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. PMID:26443399

  19. Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs

    NASA Technical Reports Server (NTRS)

    Rubin, Leslie; Federico, Frank; Formato, Richard; Larouco, John; Slager, William

    2004-01-01

    Tubes made from biaxially oriented liquid-crystal polymers (LCPs) have been developed for use as penetrations on cryogenic tanks. ( Penetrations in this context denotes feed lines, vent lines, and sensor tubes, all of which contribute to the undesired conduction of heat into the tanks.) In comparison with corresponding prior cryogenic-tank penetrations made from stainless steels and nickel alloys, the LCP penetrations offer advantages of less weight and less thermal conduction. An additional major advantage of LCP components is that one can tailor their coefficients of thermal expansion (CTEs). The estimated cost of continuous production of LCP tubes of typical sizes is about $1.27/ft ($4.17/m) [based on 1998 prices]. LCP tubes that are compatible with liquid oxygen and that feature tailored biaxial molecular orientation and quasi-isotropic properties (including quasi-isotropic CTE) have been fabricated by a combination of proprietary and patented techniques that involve the use of counterrotating dies (CRDs). Tailoring of the angle of molecular orientation is what makes it possible to tailor the CTE over a wide range to match the CTEs of adjacent penetrations of other tank components; this, in turn, makes it possible to minimize differential-thermal expansion stresses that arise during thermal cycling. The fabrication of biaxially oriented LCP tubes by use of CRDs is not new in itself. The novelty of the present development lies in tailoring the orientations and thus the CTEs and other mechanical properties of the LCPs for the intended cryogenic applications and in modifications of the CRDs for this purpose. The LCP tubes and the 304-stainless-steel tubes that the LCP tubes were intended to supplant were tested with respect to burst strength, permeability, thermal conductivity, and CTE.

  20. Design Of A Novel Open-Path Aerosol Extinction Cavity Ringdown Spectrometer And Initial Data From Deployment At NOAA's Atmospheric Observatory

    NASA Astrophysics Data System (ADS)

    Gordon, T. D.; Wagner, N. L.; Richardson, M.; Law, D. C.; Wolfe, D. E.; Brock, C. A.; Erdesz, F.; Murphy, D. M.

    2014-12-01

    The ability to frame effective climate change policy depends strongly on reducing the uncertainty in aerosol radiative forcing, which is currently nearly as great as best estimates of its magnitude. Achieving this goal will require significant progress in measuring aerosol properties, including aerosol optical depth, single scattering albedo and the effect of relative humidity on these properties for both fine and coarse particles. However both ground- and space-based instruments fail or are highly biased in the presence of clouds, severely limiting quantitative estimates of the radiative effects of aerosols where they are advected over low-level clouds. Moreover, many in situ aerosol measurements exclude the coarse fraction, which can be very important in and downwind of desert regions. By measuring the decay rate of a pulsed laser in an optically resonant cavity, cavity ringdown spectrometers (CRDSs) have been employed successfully in measuring aerosol extinction for particles in relative humidities below 90%. At very high humidities (as found in and near clouds), however, existing CRDSs perform poorly, diverging significantly from theoretical extinction values as humidities approach 100%. The new open-path aerosol extinction CRDS described in this poster measures extinction as aerosol is drawn through the sample cavity directly without inlets or tubing for channeling the flow, which cause particle losses, condensation at high RH and other artifacts. This poster presents the key elements of the new open-path CRDS design as well as comparisons with an earlier generation closed-path CRDS and preliminary data obtained during a field study at the 300 meter tower at NOAA's Boulder Atmospheric Observatory (BAO) in Colorado.

  1. Using Mid-IR Cavity Ring-Down Spectrometry to Simultaneously Measure N2o, CO2, and CH4 Fluxes: Responses to Ammonium Nitrate Additions in Salt Marshes

    NASA Astrophysics Data System (ADS)

    Brannon, E.; Moseman-Valtierra, S.; Tang, J.; Chen, X.; Martin, R.; Garate, M.

    2014-12-01

    Greenhouse gas emissions from salt marshes, especially of nitrous oxide (N2O), are a central interest because anthropogenic nutrient loads may substantially alter net climatic forcing of these globally significant ecosystems. In a series of lab and field experiments, a new cavity ring down spectrometer (CRDS, Picarro G2508) that uses mid-infrared (mid-IR) frequencies to measure N2O was compared to a near-IR gas analyzer (LGR N2O/CO analyzer). The Picarro G2508 reports N2O as well as CO2 and CH4 concentrations roughly every second at the parts per billion level. Responses of N2O fluxes to experimental ammonium nitrate additions in marsh mesocosms and marsh plots in situ were compared among these analyzers, along with minimum detectable N2O fluxes. At fluxes above 150 μmol N2O m-2 d-1, the Picarro G2508 and LGR analyzers performed similarly in both mesocosm and field plots that had been enriched with ammonium nitrate, however there were significantly lower minimum detectable N2O fluxes (about 1 order of magnitude) for the LGR than for the Picarro. A gas chromatograph (Shimadzu GC 2014) was also used to test calibration of the G2508. These experiments suggest that mid-IR CRDS technology offers a new tool for simultaneous analyses of N2O along with CO2 and CH4, which fills an important need for quantifying the net climatic forcing of ecosystems. However based on relatively high minimum N2O detection levels of the CRDS, it may work best in highly eutrophic environments.

  2. The association between depressive disorders and health care utilization: results from the São Paulo ageing and health study (SPAH).

    PubMed

    Huang, Hsiang; Menezes, Paulo R; da Silva, Simone A; Tabb, Karen; Barkil-Oteo, Andres; Scazufca, Marcia

    2014-01-01

    Although depressive disorders are associated with increased health care utilization in the elderly living in high-income countries, few studies have examined this relationship in Latin America. The present study is part of the São Paulo Ageing and Health Study, a population-based epidemiological study of mental disorders in 2072 low-income adults ≥ 65 years old living in São Paulo, Brazil. Depressive disorders defined as major depressive disorder (MDD) and clinically relevant depressive symptoms (CRDS) were assessed with the Geriatric Mental State and the Neuropsychiatric Inventory. We examined the association between depressive disorders/symptoms and health care utilization (outpatient visits, hospital admissions and medication use in the past 3 months) using count models. The prevalence of MDD and CRDS was 4.9% and 21.4%, respectively. In the fully adjusted model, older adults with MDD were 36% more likely to have one more outpatient visit (RM: 1.36, 95% CI: 1.11-1.67), while older adults with CRDS were 14% more likely to have one more outpatient visit (RM: 1.14, 95% CI: 1.02-1.28). Elderly individuals with MDD had a prevalence of hospital admissions in the previous 3 months that was twice that of those without depression (PR=2.02, 95% CI: 1.09-3.75). Significant differences were not found for medication use. Among low-income older adults living in Brazil, those with MDD are more likely to have a recent hospital admission and outpatient service use than those without depression. Future studies are needed to examine the effectiveness of depression treatments for this population in order to both decrease the burden of illness as well as to minimize health care utilization related to depression. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Local- and regional-scale measurements of CH4, δ13CH4, and C2H6 in the Uintah Basin using a mobile stable isotope analyzer

    NASA Astrophysics Data System (ADS)

    Rella, C. W.; Hoffnagle, J.; He, Y.; Tajima, S.

    2015-10-01

    In this paper, we present an innovative CH4, δ13CH4, and C2H6 instrument based on cavity ring-down spectroscopy (CRDS). The design and performance of the analyzer is presented in detail. The instrument is capable of precision of less than 1 ‰ on δ13CH4 with 1 in. of averaging and about 0.1 ‰ in an hour. Using this instrument, we present a comprehensive approach to atmospheric methane emissions attribution. Field measurements were performed in the Uintah Basin (Utah, USA) in the winter of 2013, using a mobile lab equipped with the CRDS analyzer, a high-accuracy GPS, a sonic anemometer, and an onboard gas storage and playback system. With a small population and almost no other sources of methane and ethane other than oil and gas extraction activities, the Uintah Basin represents an ideal location to investigate and validate new measurement methods of atmospheric methane and ethane. We present the results of measurements of the individual fugitive emissions from 23 natural gas wells and six oil wells in the region. The δ13CH4 and C2H6 signatures that we observe are consistent with the signatures of the gases found in the wells. Furthermore, regional measurements of the atmospheric CH4, δ13CH4, and C2H6 signatures throughout the basin have been made, using continuous sampling into a 450 m long tube and laboratory reanalysis with the CRDS instrument. These measurements suggest that 85 ± 7 % of the total emissions in the basin are from natural gas production.

  4. Statistics, Structures & Satisfied Customers: Using Web Log Data to Improve Site Performance.

    ERIC Educational Resources Information Center

    Peacock, Darren

    This paper explores some of the ways in which the National Museum of Australia is using Web analysis tools to shape its future directions in the delivery of online services. In particular, it explores the potential of quantitative analysis, based on Web server log data, to convert these ephemeral traces of user experience into a strategic…

  5. A gas chromatograph for quantification of peroxycarboxylic nitric anhydrides calibrated by thermal dissociation cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Tokarek, T. W.; Huo, J. A.; Odame-Ankrah, C. A.; Hammoud, D.; Taha, Y. M.; Osthoff, H. D.

    2014-10-01

    The peroxycarboxylic nitric anhydrides (PANs, molecular formula: RC(O)O2NO2) can readily be observed by gas chromatography (PAN-GC) coupled to electron capture detection. Calibration of a PAN-GC remains a challenge, because the response factors differ for each of the PANs, and because their synthesis in sufficiently high purity is non-trivial, in particular for PANs containing unsaturated side chains. In this manuscript, a PAN-GC and its calibration using diffusion standards, whose output was quantified by blue diode laser thermal dissociation cavity ring-down spectroscopy (TD-CRDS), are described. The PAN-GC peak areas correlated linearly with total peroxy nitrate (ΣPN) mixing ratios measured by TD-CRDS (r > 0.96). Accurate determination of response factors required the concentrations of PAN impurities in the synthetic standards to be subtracted from ΣPN. The PAN-GC and its TD-CRDS calibration method were deployed during ambient air measurement campaigns in Abbotsford, BC, from 20 July to 5 August 2012, and during the Fort McMurray Oil Sands Strategic Investigation of Local Sources (FOSSILS) campaign at the AMS13 ground site in Fort McKay, AB, from 10 August to 5 September 2013. The PAN-GC limits of detection for PAN, PPN, and MPAN during FOSSILS were 1, 2, and 3 pptv, respectively. For the Abbotsford data set, the PAN-GC mixing ratios were compared, and agreed with those determined in parallel by thermal dissociation chemical ionization mass spectrometry (TD-CIMS). Advantages and disadvantages of the PAN measurement techniques used in this work and the utility of TD-CRDS as a PAN-GC calibration method are discussed.

  6. Improved CRDS δ13C Stability Through New Calibration Application For CO2 and CH4

    NASA Astrophysics Data System (ADS)

    Arata, C.; Rella, C.

    2014-12-01

    Stable carbon isotope ratio measurements of CO2 and CH4 provide valuable insight into global and regional sources and sinks of the two most important greenhouse gasses. Methodologies based on Cavity Ring-Down Spectroscopy (CRDS) have been developed capable of delivering δ13C measurements with a precision greater than 0.12 permil for CO2 and 0.4 permil for CH4 (1 hour window, 5 minute average). Here we present a method to further improve this measurement's stability. We have developed a two point calibration method which corrects for δ13C drift due to a dependance on carbon species concentration. This method calibrates for both carbon species concentration as well as δ13C. We go on to show that this added stability is especially valuable when using carbon isotope data in linear regression models such as Keeling plots, where even small amounts of error can be magnified to give inconclusive results. This method is demonstrated in both laboratory and ambient atmospheric conditions, and we demonstrate how to select the calibration frequency.

  7. Initial evaluation of airborne water vapour measurements by the IAGOS-GHG CRDS system

    NASA Astrophysics Data System (ADS)

    Filges, Annette; Gerbig, Christoph; Smit, Herman G. J.; Krämer, Martina; Spelten, Nicole

    2013-04-01

    Accurate and reliable airborne measurements of water vapour are still a challenge. Presently, no airborne humidity sensor exists that covers the entire range of water vapour content between the surface and the upper troposphere/lower stratosphere (UT/LS) region with sufficient accuracy and time resolution. Nevertheless , these data are a pre-requisite to study the underlying processes in the chemistry and physics of the atmosphere. The DENCHAR project (Development and Evaluation of Novel Compact Hygrometer for Airborne Research) addresses this deficit by developing and characterizing novel or improved compact airborne hygrometers for different airborne applications within EUFAR (European Facility for Airborne Research). As part of the DENCHAR inter-comparison campaign in Hohn (Germany), 23 May - 1 June 2011, a commercial gas analyzer (G2401-m, Picarro Inc.,US), based on cavity ring-down spectroscopy (CRDS), was installed on a Learjet to measure water vapour, CO2, CH4 and CO. The CRDS components are identical to those chosen for integration aboard commercial airliner within IAGOS (In-service Aircraft for a Global Observing System). Thus the campaign allowed for the initial assessment validation of the long-term IAGOS H2O measurements by CRDS against reference instruments with a long performance record (FISH, the Fast In-situ Stratospheric Hygrometer, and CR2 frostpoint hygrometer, both research centre Juelich). The inlet system, a one meter long 1/8" FEP-tube connected to a Rosemount TAT housing (model 102BX, deiced) installed on a window plate of the aircraft, was designed to eliminate sampling of larger aerosols, ice particles, and water droplets, and provides about 90% of ram-pressure. In combination with a lowered sample flow of 0.1 slpm (corresponding to a 4 second response time), this ensured a fully controlled sample pressure in the cavity of 140 torr throughout an aircraft altitude operating range up to 12.5 km without the need of an upstream sampling pump. This setup ensures full compatibility with the future deployment of the analyser within IAGOS. For the initial water calibration of the instrument, a calibration of a similar instrument performed at MPI-BGC Jena against a dew point mirror (Dewmet, Michell instruments Ltd., UK) in the range from 0.7 to 3.0% was transferred to all subsequently manufactured CRDS instruments by Picarro. During the campaign the analyzer was compared against a reference frost point hygrometer, which is also used for calibration of the reference instrument FISH. The dew point mirror calibration was within 0.7 % of the FISH calibrator, but showed an offset of 14.45 ppm, which is consistent with the H2O content of dry tank air and diffusion effects through the inlet line (FEP). Furthermore, a new independent calibration method, based on the dilution effect of water vapour on CO2, was tested. It showed a 9 % low bias compared to the dew point mirror calibration. Comparison of the in-flight data against the reference systems showed that the analyzer is reliable and has a good long-term stability. Flight data from the DENCHAR campaign suggest a conservative precision estimate for measurements made at 0.4 Hz of 4 ppm for H2O < 100 ppm, and 4 % (relative) for H2O > 100 ppm. Accuracy at mixing ratios below 50 ppm was difficult to assess, as the reference instruments suffered from lack of stability. We present the results of the campaign flights and comparison with the reference instruments. The different calibration methods will be discussed.

  8. Crash response data system for the controlled impact demonstration (CID) of a full scale transport aircraft

    NASA Astrophysics Data System (ADS)

    Calloway, Raymond S.; Knight, Vernie H., Jr.

    NASA Langley's Crash Response Data System (CRDS) which is designed to acquire aircraft structural and anthropomorphic dummy responses during the full-scale transport CID test is described. Included in the discussion are the system design approach, details on key instrumentation subsystems and operations, overall instrumentation crash performance, and data recovery results. Two autonomous high-environment digital flight instrumentation systems, DAS 1 and DAS 2, were employed to obtain research data from various strain gage, accelerometer, and tensiometric sensors installed in the B-720 test aircraft. The CRDS successfully acquired 343 out of 352 measurements of dynamic crash data.

  9. Cavity ring-down spectroscopy in the liquid phase

    NASA Astrophysics Data System (ADS)

    Xu, Shucheng; Sha, Guohe; Xie, Jinchun

    2002-02-01

    A new application for cavity ring-down spectroscopic (CRDS) technique using a pulsed polarized light source has been developed in the absorption measurement of liquids for "colorless" organic compounds using both a single sample cell and double sample cells inserted in an optical cavity at Brewster angle. At present an experimental capability of measuring absorption coefficients as small as 2-5×10-7 cm-1 has been demonstrated by measurement of the absorption baselines. The first spectra for CRDS in the liquid phase, the C-H stretching fifth vibrational overtones of benzene in the pure liquid and hexane solution are obtained. The optical absorption length for liquids in both a single sample cell and double sample cells of 1 cm length is up to 900 cm due to multipass of light within an optical cavity. Compared to the thermal lens and optoacoustic spectroscopic techniques, the sensitivity for CRDS mainly depends on the optical absorption path of the sample (single passing path of the sample times multipass times), is not determined by the laser power and the length of the sample cell. The absolute absorption coefficient and band intensity for the sample are determined directly by the spectroscopy.

  10. Boiling water reactor radiation shielded Control Rod Drive Housing Supports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baversten, B.; Linden, M.J.

    1995-03-01

    The Control Rod Drive (CRD) mechanisms are located in the area below the reactor vessel in a Boiling Water Reactor (BWR). Specifically, these CRDs are located between the bottom of the reactor vessel and above an interlocking structure of steel bars and rods, herein identified as CRD Housing Supports. The CRD Housing Supports are designed to limit the travel of a Control Rod and Control Rod Drive in the event that the CRD vessel attachement went to fail, allowing the CRD to be ejected from the vessel. By limiting the travel of the ejected CRD, the supports prevent a nuclearmore » overpower excursion that could occur as a result of the ejected CRD. The Housing Support structure must be disassembled in order to remove CRDs for replacement or maintenance. The disassembly task can require a significant amount of outage time and personnel radiation exposure dependent on the number and location of the CRDs to be changed out. This paper presents a way to minimize personal radiation exposure through the re-design of the Housing Support structure. The following paragraphs also delineate a method of avoiding the awkward, manual, handling of the structure under the reactor vessel during a CRD change out.« less

  11. Deviations from plane-wave Mie scattering and precise retrieval of refractive index for a single spherical particle in an optical cavity.

    PubMed

    Mason, Bernard J; Walker, Jim S; Reid, Jonathan P; Orr-Ewing, Andrew J

    2014-03-20

    The extinction cross-sections of individual, optically confined aerosol particles with radii of a micrometer or less can, in principle, be measured using cavity ring-down spectroscopy (CRDS). However, when the particle radius is comparable in magnitude to the wavelength of light stored in a high-finesse cavity, the phenomenological cross-section retrieved from a CRDS experiment depends on the location of the particle in the intracavity standing wave and differs from the Mie scattering cross-section for plane-wave irradiation. Using an evaporating 1,2,6-hexanetriol particle of initial radius ∼1.75 μm confined within the 4.5 μm diameter core of a Bessel beam, we demonstrate that the scatter in the retrieved extinction efficiency of a single particle is determined by its lateral motion, which spans a few wavelengths of the intracavity standing wave used for CRDS measurements. Fits of experimental measurements to Mie calculations, modified to account for the intracavity standing wave, allow precise retrieval of the refractive index of 1,2,6-hexanetriol particles (with relative humidity, RH < 10%) of 1.47824 ± 0.00072.

  12. Alteration of the carbohydrate-binding specificity of a C-type lectin CEL-I mutant with an EPN carbohydrate-binding motif.

    PubMed

    Hatakeyama, Tomomitsu; Ishimine, Tomohiro; Baba, Tomohiro; Kimura, Masanari; Unno, Hideaki; Goda, Shuichiro

    2013-07-01

    CEL-I is a Gal/GalNAc-specific C-type lectin isolated from the sea cucumber Cucumaria echinata. This lectin is composed of two carbohydrate-recognition domains (CRDs) with the carbohydrate-recognition motif QPD (Gln-Pro- Asp), which is generally known to exist in galactose-specific C-type CRDs. In the present study, a mutant CEL-I with EPN (Glu-Pro-Asn) motif, which is thought to be responsible for the carbohydrate-recognition of mannose-specific Ctype CRDs, was produced in Escherichia coli, and its effects on the carbohydrate-binding specificity were examined using polyamidoamine dendrimer (PD) conjugated with carbohydrates. Although wild-type CEL-I effectively formed complexes with N-acetylgalactosamine (GalNAc)-PD but not with mannose-PD, the mutant CEL-I showed relatively weak but definite affinity for mannose-PD. These results indicated that the QPD and EPN motifs play a significant role in the carbohydrate-recognition mechanism of CEL-I, especially in the discrimination of galactose and mannose. Additional mutations in the recombinant CEL-I binding site may further increase its specificity for mannose, and should provide insights into designing novel carbohydrate-recognition proteins.

  13. T-RMSD: a fine-grained, structure-based classification method and its application to the functional characterization of TNF receptors.

    PubMed

    Magis, Cedrik; Stricher, François; van der Sloot, Almer M; Serrano, Luis; Notredame, Cedric

    2010-07-16

    This study addresses the relation between structural and functional similarity in proteins. We introduce a novel method named tree based on root mean square deviation (T-RMSD), which uses distance RMSD (dRMSD) variations to build fine-grained structure-based classifications of proteins. The main improvement of the T-RMSD over similar methods, such as Dali, is its capacity to produce the equivalent of a bootstrap value for each cluster node. We validated our approach on two domain families studied extensively for their role in many biological and pathological pathways: the small GTPase RAS superfamily and the cysteine-rich domains (CRDs) associated with the tumor necrosis factor receptors (TNFRs) family. Our analysis showed that T-RMSD is able to automatically recover and refine existing classifications. In the case of the small GTPase ARF subfamily, T-RMSD can distinguish GTP- from GDP-bound states, while in the case of CRDs it can identify two new subgroups associated with well defined functional features (ligand binding and formation of ligand pre-assembly complex). We show how hidden Markov models (HMMs) can be built on these new groups and propose a methodology to use these models simultaneously in order to do fine-grained functional genomic annotation without known 3D structures. T-RMSD, an open source freeware incorporated in the T-Coffee package, is available online. 2010 Elsevier Ltd. All rights reserved.

  14. Application of Allan Deviation to Assessing Uncertainties of Continuous-measurement Instruments, and Optimizing Calibration Schemes

    NASA Astrophysics Data System (ADS)

    Jacobson, Gloria; Rella, Chris; Farinas, Alejandro

    2014-05-01

    Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits of Signal Averaging in Atmospheric Trace-Gas Monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS)," Applied Physics, B57, pp 131-139, April 1993

  15. Characterization of interferences to in situ observations of δ13CH4 and C2H6 when using a cavity ring-down spectrometer at industrial sites

    NASA Astrophysics Data System (ADS)

    Assan, Sabina; Baudic, Alexia; Guemri, Ali; Ciais, Philippe; Gros, Valerie; Vogel, Felix R.

    2017-06-01

    Due to increased demand for an understanding of CH4 emissions from industrial sites, the subject of cross sensitivities caused by absorption from multiple gases on δ13CH4 and C2H6 measured in the near-infrared spectral domain using CRDS has become increasingly important. Extensive laboratory tests are presented here, which characterize these cross sensitivities and propose corrections for the biases they induce. We found methane isotopic measurements to be subject to interference from elevated C2H6 concentrations resulting in heavier δ13CH4 by +23.5 ‰ per ppm C2H6 / ppm CH4. Measured C2H6 is subject to absorption interference from a number of other trace gases, predominantly H2O (with an average linear sensitivity of 0.9 ppm C2H6 per % H2O in ambient conditions). Yet, this sensitivity was found to be discontinuous with a strong hysteresis effect and we suggest removing H2O from gas samples prior to analysis. The C2H6 calibration factor was calculated using a GC and measured as 0.5 (confirmed up to 5 ppm C2H6). Field tests at a natural gas compressor station demonstrated that the presence of C2H6 in gas emissions at an average level of 0.3 ppm shifted the isotopic signature by 2.5 ‰, whilst after calibration we find that the average C2H6 : CH4 ratio shifts by +0.06. These results indicate that, when using such a CRDS instrument in conditions of elevated C2H6 for CH4 source determination, it is imperative to account for the biases discussed within this study.

  16. Head Trajectories of Restrained Child Dummy in Sled Tests Over 56 kph Delta-V

    PubMed Central

    Hauschild, Hans W.

    2000-01-01

    Child restraint devices (CRDs) have been used for many years to protect children in automotive crashes. The following data was collected to find out whether current restraints would be able to pass more stringent dynamic testing at higher changes in velocity (delta-v), such as the NHTSA NCAP program or the IIHS offset barrier test, and to look at one possible misuse mode. Three basic types of CRDs were sled tested at a delta-v between 57.5 & 61.4 kph (35.7 & 38.1 mph). Data from each test are presented and compared. Comparisons are made between each seat’s sled test results and various countries’ standards. PMID:11558089

  17. Mid-Infrared Trace Gas Sensor Technology Based on Intracavity Quartz-Enhanced Photoacoustic Spectroscopy.

    PubMed

    Wojtas, Jacek; Gluszek, Aleksander; Hudzikowski, Arkadiusz; Tittel, Frank K

    2017-03-04

    The application of compact inexpensive trace gas sensor technology to a mid-infrared nitric oxide (NO) detectoion using intracavity quartz-enhanced photoacoustic spectroscopy (I-QEPAS) is reported. A minimum detection limit of 4.8 ppbv within a 30 ms integration time was demonstrated by using a room-temperature, continuous-wave, distributed-feedback quantum cascade laser (QCL) emitting at 5.263 µm (1900.08 cm -1 ) and a new compact design of a high-finesse bow-tie optical cavity with an integrated resonant quartz tuning fork (QTF). The optimum configuration of the bow-tie cavity was simulated using custom software. Measurements were performed with a wavelength modulation scheme (WM) using a 2f detection procedure.

  18. Recent advances in quartz enhanced photoacoustic sensing

    NASA Astrophysics Data System (ADS)

    Patimisco, Pietro; Sampaolo, Angelo; Dong, Lei; Tittel, Frank K.; Spagnolo, Vincenzo

    2018-03-01

    This review aims to discuss the latest advancements in quartz-enhanced photoacoustic spectroscopy (QEPAS) based trace-gas sensing. Starting from the QEPAS basic physical principles, the most used QEPAS configurations will be described. This is followed by a detailed theoretical analysis and experimental study regarding the influence of quartz tuning forks (QTFs) geometry on their optoacoustic transducer performance. Furthermore, an overview of the latest developments in QEPAS trace-gas sensor technology employing custom QTFs will be reported. Results obtained by exploiting novel micro-resonator configurations, capable of increasing the QEPAS signal-to-noise ratio by more than two orders of magnitude and the utilization of QTF overtone flexural modes for QEPAS based sensing will be presented. A comparison of the QEPAS performance of different spectrophone configurations is reported based upon signal-to-noise ratio. Finally, a novel QEPAS approach allowing simultaneous dual-gas detection will be described.

  19. Molecular cloning of a C-type lectin (LvLT) from the shrimp Litopenaeus vannamei: early gene down-regulation after WSSV infection.

    PubMed

    Ma, Tracy Hoi Tung; Tiu, Shirley Hiu Kwan; He, Jian-Guo; Chan, Siu-Ming

    2007-08-01

    C-type lectin is one of the pattern-recognition proteins of the non-self innate immune system in the invertebrates. In this study, a lectin-like cDNA (LvLT) of Litopenaeus vannamei was cloned and characterized. LvLT cDNA consists of 1035 nt encoding for a protein with 345 amino acid residues. The deduced LvLT consists of two putative carbohydrate-recognition domains (CRDs) as found in most C-type lectins. The first CRD consists of an amino acid motif (QPD) for the binding of galactose and the other CRDs consist of amino acid motifs (EPN) for the binding of mannose. Except for some conserved amino acid residues, the CRD of LvLT shared an overall low amino acid sequence identity with CRDs of other lectins. Unlike other shrimp lectins, LvLT is expressed only in the hepatopancreas but not in the hemocytes as revealed by RT-PCR. When juvenile shrimp were challenged with shrimp extracts containing white spot syndrome virus (WSSV), the expression levels of LvLT decreased initially in the first 2 h and then increased to a much higher level after 4 h. The results suggest that the initial reduction in LvLT transcript level may be related to the WSSV infection in shrimp.

  20. Characterisation and functional comparison of single-CRD and multidomain containing galectins CgGal-2 and CgGal-3 from oyster Crassostrea gigas.

    PubMed

    Huang, Mengmeng; Zhou, Tao; Wu, Yuehong; Fei, Hui; Wang, Gaoyang; Li, Zhi; Lei, Yutong; Liu, Qian; Sun, Cong; Lv, Zhengbing; Xu, Xue-Wei

    2018-04-18

    Galectins are β-galactoside binding lectins that play crucial roles in innate immunity in vertebrates and invertebrates through their conserved carbohydrate-recognition domains (CRDs). In the present study, single- and four-CRD-containing galectins were identified in oyster Crassostrea gigas (designated CgGal-2 and CgGal-3). The open reading frames (ORFs) of CgGal-2 and CgGal-3 encode polypeptides of 200 and 555 amino acids, respectively. All CRDs of CgGal-3 include two consensus motifs essential for ligand-binding, and a novel motif is present in CgGal-2. Pathogen-associated molecular pattern (PAMP) profiles were determined for recombinant rCgGal-2 and rCgGal-3, and rCgGal-2 displayed low binding affinity for PAMPs, while rCgGal-3 bound various PAMPs including glucan, lipopolysaccharide (LPS), and peptidoglycan (PGN) with relatively high affinity. Furthermore, rCgGal-2 and rCgGal-3 exhibited different microbe binding profiles; rCgGal-2 bound to Gram-negative bacteria (Escherichia coli and Vibrio vulnificus) and fungi (Saccharomyces cerevisiae and Pichia pastoris), while rCgGal-3 bound to these microbes but also to Gram-positive bacteria (Micrococcus luteus). In addition, rCgGal-3 possessed microbial agglutinating activity and coagulation activity against fungi and erythrocytes, respectively, but rCgGal-2 lacked any agglutinating activity. Carbohydrate binding specificity analysis showed that rCgGal-3 specifically bound D-galactose. Furthermore, rCgGal-2 and rCgGal-3 functioned as opsonin participating in the clearance against invaders in C. gigas. Thus, CgGal-2 with one CRD and CgGal-3 with four CRDs are new members of the galectin family involved in immune responses against bacterial infection. Differences in the organisation and amino acid sequences of CRDs may affect their specificity and affinity for nonself substances. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Improved CRDS δ13C Stability Through New Calibration Application For CO2 And CH4

    NASA Astrophysics Data System (ADS)

    Rella, Chris; Arata, Caleb; Saad, Nabil; Leggett, Graham; Miles, Natasha; Richardson, Scott; Davis, Ken

    2015-04-01

    Stable carbon isotope ratio measurements of CO2 and CH4 provide valuable insight into global and regional sources and sinks of the two most important greenhouse gases. Methodologies based on Cavity Ring-Down Spectroscopy (CRDS) have been developed and are capable of delivering δ13C measurements with a precision better than 0.12 permil for CO2 and 0.4 permil for CH4 (1 hour window, 5 minute average). Here we present a method to further improve this measurement stability. We have developed a two-point calibration method which corrects for δ13C drift due to a dependence on carbon species concentration. This method calibrates for both carbon species concentration as well as δ13C. In addition, we further demonstrate that this added stability is especially valuable when using carbon isotope data in linear regression models such as Keeling plots, where even small amounts of error can be magnified to give inconclusive results. Furthermore, we show how this method is used to validate multiple instruments simultaneously and can be used to create the standard samples needed for field calibrations.

  2. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Surampudi, Anand B.

    2008-10-01

    We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.

  3. Testing Services

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Trace Laboratories is an independent testing laboratory specializing in testing printed circuit boards, automotive products and military hardware. Technical information from NASA Tech Briefs and two subsequent JPL Technical Support packages have assisted Trace in testing surface insulation resistance on printed circuit board materials. Testing time was reduced and customer service was improved because of Jet Propulsion Laboratory technical support packages.

  4. Isotopic analysis of dissolved organic carbon in produced water brines by wet chemical oxidation and cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Thomas, Randal; Conaway, Christopher; Saad, Nabil; Kharaka, Yousif

    2013-04-01

    Identification of fluid migration and escape from intentionally altered subsurface geologic systems, such as in hydraulic fracturing, enhanced oil recovery, and carbon sequestration activities, is an important issue for environmental regulators based on the traction that the "fracking" process is gathering across the United States. Given diverse injected fluid compositions and the potential for toxic or regulated compounds to be released, one of the most important steps in the process is accurately identifying evidence of injected fluid escape during and after injection processes. An important tool in identifying differences between the natural groundwater and injected fluid is the isotopic composition of dissolved constituents including inorganic components such as Sr and carbon isotopes of the dissolved organic compounds. Since biological processes in the mesothermal subsurface can rapidly alter the organic composition of a fluid, stable carbon isotopes of the dissolved organic compounds (DOC) are an effective means to identify differences in the origin of two fluids, especially when coupled with inorganic compound analyses. The burgeoning field of cavity ring-down spectroscopy (CRDS) for isotopic analysis presents an opportunity to obtain rapid, reliable and cost-effective isotopic measurements of DOC in potentially affected groundwater for the identification of leakage or the improvement of hydrogeochemical pathway models. Here we adapt the use of the novel hyphenated TOC-CRDS carbon isotope analyzer for the analysis of DOC in produced water by wet oxidation and describe the methods to evaluate performance and obtain useful information at higher salinities. Our methods are applied to a specific field example in a CO2-enhanced EOR field in Cranfield, Mississippi (USA) as a means to demonstrate the ability to distinguish natural and injected DOC using the stable isotopic composition of the dissolved organic carbon when employing the novel TOC-CRDS instrumentation set up.

  5. Evaluation of factors affecting accurate measurements of atmospheric CO2 and CH4 by wavelength-scanned cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Tohjima, Y.; Mukai, H.; Nojiri, Y.; Katsumata, K.; Rella, C.

    2012-07-01

    We examined potential interferences from water vapor and atmospheric background gases (N2, O2, and Ar), and biases by isotopologues of target species, on accurate measurement of atmospheric CO2 and CH4 by means of wavelength-scanned cavity ring-down spectroscopy (WS-CRDS). Variations in the composition of the background gas substantially impacted the CO2 and CH4 measurements: the measured amounts of CO2 and CH4 decreased with increasing N2 mole fraction, but increased with increasing O2 and Ar, suggesting that the pressure-broadening effects (PBEs) increased as Ar < O2 < N2. Using these experimental results, we inferred PBEs for the measurement of synthetic standard gases. The PBEs were negligible (up to 0.05 ppm for CO2 and 0.01 ppb for CH4) for gas standards balanced with purified air, although the PBEs were substantial (up to 0.87 ppm for CO2 and 1.4 ppb for CH4) for standards balanced with synthetic air. For isotopic biases on CO2 measurements, we compared experimental results and theoretical calculations, which showed excellent agreement within their uncertainty. We derived empirical correction functions for water vapor for three WS-CRDS instruments (Picarro EnviroSense 3000i, G-1301, and G-2301). Although the transferability of the functions was not clear, no significant difference was found in the water vapor correction values among these instruments within the typical analytical precision at sufficiently low water concentrations (< 0.3%V for CO2 and < 0.4%V for CH4). For accurate measurements of CO2 and CH4 in ambient air, we concluded that WS-CRDS measurements should be performed under complete dehumidification of air samples, or moderate dehumidification followed by application of a water vapor correction function, along with calibration by natural air-based standard gases or purified air-balanced synthetic standard gases with isotopic correction.

  6. Towards absolute laser spectroscopic CO2 isotope ratio measurements

    NASA Astrophysics Data System (ADS)

    Anyangwe Nwaboh, Javis; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Knowledge of isotope composition of carbon dioxide (CO2) in the atmosphere is necessary to identify sources and sinks of this key greenhouse gas. In the last years, laser spectroscopic techniques such as cavity ring-down spectroscopy (CRDS) and tunable diode laser absorption spectroscopy (TDLAS) have been shown to perform accurate isotope ratio measurements for CO2 and other gases like water vapour (H2O) [1,2]. Typically, isotope ratios are reported in literature referring to reference materials provided by e.g. the International Atomic Energy Agency (IAEA). However, there could be some benefit if field deployable absolute isotope ratio measurement methods were developed to address issues such as exhausted reference material like the Pee Dee Belemnite (PDB) standard. Absolute isotope ratio measurements would be particularly important for situations where reference materials do not even exist. Here, we present CRDS and TDLAS-based absolute isotope ratios (13C/12C ) in atmospheric CO2. We demonstrate the capabilities of the used methods by measuring CO2 isotope ratios in gas standards. We compare our results to values reported for the isotope certified gas standards. Guide to the expression of uncertainty in measurement (GUM) compliant uncertainty budgets on the CRDS and TDLAS absolute isotope ratio measurements are presented, and traceability is addressed. We outline the current impediments in realizing high accuracy absolute isotope ratio measurements using laser spectroscopic methods, propose solutions and the way forward. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] B. Kühnreich, S. Wagner, J. C. Habig,·O. Möhler, H. Saathoff, V. Ebert, Appl. Phys. B 119:177-187 (2015). [2] E. Kerstel, L. Gianfrani, Appl. Phys. B 92, 439-449 (2008).

  7. Detection of new VOC compounds with iCRDS

    NASA Astrophysics Data System (ADS)

    Huang, H.; Leen, J. B.; Gardner, A.; Gupta, M.; Baer, D. S.

    2015-12-01

    The instrument at Los Gatos Research (a member of ABB Inc.) which is based on incoherent cavity ringdown spectroscopy (iCRDS) that operates in the mid-infrared (bands from 860-1060 cm-1 or 970-1280 cm-1) is capable of detecting a broad range of VOCs, in situ, continuously and autonomously, for example, BTEX compounds (benzene, toluene, ethylbenzene, xylene), including differentiation of xylene isomers. Previously, we have demonstrated the measurement of trichloroethylene (TCE) in zero air with a precision of 0.17 ppb (1σ in 4 minutes), and the measurement of tetrachloroethylene (PCE) with a precision of 0.15 ppb (1σ in 4 minutes). Both of these measured precisions exceed the EPA's commercial building action limit, which for TCE is 0.92 ppb (5 µg/m3) and for PCE is 0.29 ppb (2 µg/m3). This ability has been fully demonstrated by the deployment of the instrument to the Superfund site at Moffett Naval Air Station in Mountain View, California where contaminated ground water results in vapor intrusion of TCE and PCE. For two weeks, the instrument operated continuously and autonomously, successfully measuring TCE and PCE concentrations in both the breathing zone and steam tunnel air, in excellent agreement with previous TO-15 data. In this poster, we present laboratory performance data targeting new toxic molecules with the same instrument. We have demonstrated the measurement of trichlorofluolomethane (Freon 11) in zero air with a precision of 1 ppb (3σ at 1075cm-1), and hexafluoropropene in zero air with a precision of about 0.3 ppb (3σ per spectrum). The iCRDS instrument has shown the ability to continuously and autonomously measure sub-ppb levels of toxic VOCs in the lab/field, offering an unprecedented picture of the short term dynamics associated with vapor intrusion and ground water pollution.

  8. Prevalence of chronic respiratory diseases from a rural area in Kerala, southern India.

    PubMed

    Viswanathan, Krishnaveni; Rakesh, P S; Balakrishnan, Shibu; Shanavas, A; Dharman, Varun

    2018-01-01

    Chronic lung diseases are one of the leading causes of morbidity in developing countries. A community based survey was undertaken with an objective to estimate the prevalence of chronic respiratory diseases and to describe the profile of people with CRDs in the rural area Nilamel health block in Kollam district, Kerala, southern India. A household information sheet and a translated respiratory symptom questionnaire based on International Union against Tuberculosis and Lung Disease (IUATLD) bronchial symptoms questionnaire was administered to 12,556 people above 15 years, selected randomly from Nilamel health block. Prevalence of self reported asthma was 2.82% (95% CI 2.52-3.12) and that of chronic bronchitis was 6.19% (95% CI 5.76-6.62) while other CRDs which did not fit to either constitute 1.89%. Prevalence of asthma among males was 2.44% (95% CI 2.05-2.85) while that of females was 3.14% (95% CI 2.71-3.57). Chronic bronchitis prevalence was 6.73% and 5.67% among males and females respectively. Although India has devised a programme to combat cancer, diabetes, cardio vascular disease and stroke, none have been devised for chronic respiratory illness till date. Considering high prevalence and its contributions to morbidity and mortality, a comprehensive programme to tackle chronic respiratory diseases is needed. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  9. Mid-Infrared Trace Gas Sensor Technology Based on Intracavity Quartz-Enhanced Photoacoustic Spectroscopy

    PubMed Central

    Wojtas, Jacek; Gluszek, Aleksander; Hudzikowski, Arkadiusz; Tittel, Frank K.

    2017-01-01

    The application of compact inexpensive trace gas sensor technology to a mid-infrared nitric oxide (NO) detectoion using intracavity quartz-enhanced photoacoustic spectroscopy (I-QEPAS) is reported. A minimum detection limit of 4.8 ppbv within a 30 ms integration time was demonstrated by using a room-temperature, continuous-wave, distributed-feedback quantum cascade laser (QCL) emitting at 5.263 µm (1900.08 cm−1) and a new compact design of a high-finesse bow-tie optical cavity with an integrated resonant quartz tuning fork (QTF). The optimum configuration of the bow-tie cavity was simulated using custom software. Measurements were performed with a wavelength modulation scheme (WM) using a 2f detection procedure. PMID:28273836

  10. IM-CRDS for the analysis of matrix-bound water isotopes: a streamlined (and updated) tool for ecohydrologists to probe small-scale variability in plants Yasuhara, S. (syasuhara@picarro.com)1,Carter, J.A. (jcarter@picarro.com)1, Dennis, K.J. (kdennis@picarro.com)1 1Picarro Inc., 3105 Patrick Henry Drive, Santa Clara, CA 95054

    NASA Astrophysics Data System (ADS)

    Yasuhara, S.

    2013-12-01

    The ability to measure the isotopic composition of matrix-bound water is valuable to many facets of earth and environmental sciences. For example, ecohydrologists use stable isotopes of oxygen and hydrogen in plant and soil water, in combination with measurements of atmospheric water vapor, surface water and precipitation, to estimate budgets of evapotranspiration. Likewise, water isotopes of oceanic water, brines and other waters with high total dissolved solids (TDS, e.g., juices) are relevant to studying large-scale oceanic circulation, small-scale mixing, groundwater contamination, the balance of evaporation to precipitation, and the provenance of food. Conventionally matrix-bound water has been extracted using cryogenic distillation, whereby water is distilled from the material in question (e.g., a leaf sample) by heating under vacuum and collecting the resultant water vapor using liquid nitrogen. The water can then be analyzed for its stable isotopic composition by a variety of methods, including isotope ratio mass spectrometry and laser techniques, such as Cavity Ring-Down Spectroscopy (CRDS). Here we present recent improvements in an alternative, and stream-lined, solution for integrated sample extraction and isotopic measurement using a Picarro Induction Module (IM) coupled to commercially-available CRDS analyzer from Picarro. This technique is also valuable for waters with high TDS, which can have detrimental effects on flash vaporization process, typically used for the introduction of water to Picarro CRDS water isotope analyzers. The IM works by inductively heating a sample held within a metal sample holder in a glass vial flushed with dry air. Tested samples include leaves, stems, twigs, calibration water, juices, and salt water. The heating process evolves water vapor which is then swept through the system at approximately 150 standard cubic centimeters per minute. The evolved water vapor passes through an activated charcoal cartridge for removal of large organics, and then through Picarro's Micro-Combustion Cartridge that acts to oxidize interfering organics to CO2 and H2O. Using an open-split, the IM is interfaced directly with a CRDS system (in this case, an L2130-i) for the measurement of δ18O and δD. Based on replicate measurements of water introduced to the system using glass filter paper, the precision of the system is better than 0.35 and 1.5 ‰ for δ18O and δD, respectively. We will present improvements in system operation that have reduced systematic errors associated with (i) variable backgrounds, and (ii) exchange between the sample and the local atmosphere during sample introduction. In addition, we will present calibration data, and data demonstrating the effectiveness of the Micro-Combustion Cartridge at removing organics, which can result in spectroscopic interference. Finally, we will compare localized leaf water data against integrated whole leaf water data to demonstrate the added value of being able to sample small (approximately 5 mm diameter) areas of a leaf, and compare the results of measuring samples with high TDS on an IM and a Picarro High Precision Vaporizer.

  11. Flux Chamber Measurements of Methane Emissions and Stable Isotope Composition from an Arctic Wetland Using Field-Deployed Real-Time CRDS Vs Lab Measurements

    NASA Astrophysics Data System (ADS)

    Thompson, H. A.; Stern, J. C.; Graham, H. V.; Pratt, L. M.; White, J. R.

    2014-12-01

    The emission of CH4 from Arctic landscapes under warming climate is an important feedback in Earth's climate system. Studies of CH4 flux from Arctic wetlands have been growing in recent years, but few provide details on biogeochemical controls. Stable isotopic measurements help elucidate methane production and consumption pathways and offer important understanding about dynamics of CH4 cycling in Arctic systems. In order to demonstrate the possible instrumental approaches to measuring methane dynamics of wetlands in the Arctic, a fringing wetland of a small lake near the Russell Glacier in Southwestern Greenland was outfitted with static flux chambers and instrumented with a field-deployable Cavity Ring Down Spectrometer (CRDS) to measure real-time concentrations of CH4 and CO2 and their stable carbon isotopes. Several different wetland plant communities were included in the flux chamber experiments and field tests were conducted during several weeks in July 2014. Analytical measurements by CRDS were compared to batch samples analyzed in the laboratory using both Off-Axis Integrated Cavity Output Spectroscopy (ICOS) and Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry (GC-C-IRMS) with cryogenic pre-concentration. Results from flux chamber deployments will be presented and comparisons between the real-time field measurements and laboratory instrumental techniques will be evaluated.

  12. Determination of dissolved methane in natural waters using headspace analysis with cavity ring-down spectroscopy.

    PubMed

    Roberts, Hannah M; Shiller, Alan M

    2015-01-26

    Methane (CH4) is the third most abundant greenhouse gas (GHG) but is vastly understudied in comparison to carbon dioxide. Sources and sinks to the atmosphere vary considerably in estimation, including sources such as fresh and marine water systems. A new method to determine dissolved methane concentrations in discrete water samples has been evaluated. By analyzing an equilibrated headspace using laser cavity ring-down spectroscopy (CRDS), low nanomolar dissolved methane concentrations can be determined with high reproducibility (i.e., 0.13 nM detection limit and typical 4% RSD). While CRDS instruments cost roughly twice that of gas chromatographs (GC) usually used for methane determination, the process presented herein is substantially simpler, faster, and requires fewer materials than GC methods. Typically, 70-mL water samples are equilibrated with an equivalent amount of zero air in plastic syringes. The equilibrated headspace is transferred to a clean, dry syringe and then drawn into a Picarro G2301 CRDS analyzer via the instrument's pump. We demonstrate that this instrument holds a linear calibration into the sub-ppmv methane concentration range and holds a stable calibration for at least two years. Application of the method to shipboard dissolved methane determination in the northern Gulf of Mexico as well as river water is shown. Concentrations spanning nearly six orders of magnitude have been determined with this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. δ13C and δ18O measurements of carbonate rocks using Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Lucic, G.; Kim-Hak, D.; Curtis, J. H.

    2017-12-01

    We present a novel, user friendly and cost effective method for the analysis of δ13C and δ18O in CO2 gas obtained from acid digestion of carbonate rocks. 2 to 3 milligrams of pure carbonate, ground to a powder, is digested in a pre-evacuated glass vial using 100% phosphoric acid at 70° C. Vials with the reacted samples are then loaded onto an automated carousel sampler where produced CO2 gas in the headspace is extracted and sent to a Picarro CRDS isotopic C and O analyzer. Once loaded onto the carousel, 49 samples may be analyzed automatically at a rate of one sample every 15 minutes. δ13C and δ18O of the sample are reported in real time with a precision of 0.2 and 0.4 per mil, respectively. The portability and simplicity of the autosampler and CRDS setup opens up potential for permanent and mobile deployments, enabling near-realtime sampling feedback in the lab or on the go in the field. Consumable and operating costs are small when compared to other technology in use, making the CRDS-Carbonate system suitable for large and small research labs. Finally, we present a summary results from a series of validation tests in which standards and natural carbonate rock samples were analyzed and compared to traditional Kiel-IRMS results.

  14. [The contribution of biomechanics to the safety of children inside motor vehicles].

    PubMed

    Brun-Cassan, F; Cailleret, M C; Tarrière, C

    1992-03-01

    Because laws mandating use of seat belts by motor vehicle drivers and front seat passengers have been passed throughout the developed world, it is becoming increasingly common to see parents protected from injuries whereas their children are abandoned to the tragic effects of chance and biomechanics. In France, the situation is especially critical. The law passed in 1975 requiring that all children use the back seat has reduced the risk of death and severe injury but nevertheless affords inadequate protection: each year, among children aged 0 to 10 years, several hundred are killed and nearly 10,000 injured in car accidents. This situation can be decisively improved, as shown by the figures in the United States and most European countries where use of child restraint devices (CRD) is mandatory. CRDs are designed to protect the child in the event of an accident by reducing the risk of injury due to ejection or projection against the inside of the vehicle: they play the same role as the seat belt for adults. France is the European country with the lowest rate of use of CRDs and the highest rate of child deaths due to motor vehicle occupant injuries. To improve this situation, regulations are being developed by the French government; use of appropriate CRDs will be mandatory for all children aged 0 to 10 years starting on January 1 st, 1992.

  15. Optimizing python-based ROOT I/O with PyPy's tracing just-in-time compiler

    NASA Astrophysics Data System (ADS)

    Tlp Lavrijsen, Wim

    2012-12-01

    The Python programming language allows objects and classes to respond dynamically to the execution environment. Most of this, however, is made possible through language hooks which by definition can not be optimized and thus tend to be slow. The PyPy implementation of Python includes a tracing just in time compiler (JIT), which allows similar dynamic responses but at the interpreter-, rather than the application-level. Therefore, it is possible to fully remove the hooks, leaving only the dynamic response, in the optimization stage for hot loops, if the types of interest are opened up to the JIT. A general opening up of types to the JIT, based on reflection information, has already been developed (cppyy). The work described in this paper takes it one step further by customizing access to ROOT I/O to the JIT, allowing for fully automatic optimizations.

  16. Sensor for Monitoring Nanodevice-Fabrication Plasmas

    NASA Technical Reports Server (NTRS)

    Bolshakov, Alexander

    2004-01-01

    The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

  17. Effect of air composition (N2, O2, Ar, and H2O) on CO2 and CH4 measurement by wavelength-scanned cavity ring-down spectroscopy: calibration and measurement strategy

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Tohjima, Y.; Mukai, H.; Nojiri, Y.; Katsumata, K.; Rella, C. W.

    2012-11-01

    We examined potential interferences from water vapor and atmospheric background gases (N2, O2, and Ar), and biases by isotopologues of target species, on accurate measurement of atmospheric CO2 and CH4 by means of wavelength-scanned cavity ring-down spectroscopy (WS-CRDS). Changes of the background gas mole fractions in the sample air substantially impacted the CO2 and CH4 measurements: variation of CO2 and CH4 due to relative increase of each background gas increased as Ar < O2 < N2, suggesting similar relation for the pressure-broadening effects (PBEs) among the background gas. The pressure-broadening coefficients due to variations in O2 and Ar for CO2 and CH4 are empirically determined from these experimental results. Calculated PBEs using the pressure-broadening coefficients are linearly correlated with the differences between the mole fractions of O2 and Ar and their ambient abundances. Although the PBEs calculation showed that impact of natural variation of O2 is negligible on the CO2 and CH4 measurements, significant bias was inferred for the measurement of synthetic standard gases. For gas standards balanced with purified air, the PBEs were estimated to be marginal (up to 0.05 ppm for CO2 and 0.01 ppb for CH4) although the PBEs were substantial (up to 0.87 ppm for CO2 and 1.4 ppb for CH4) for standards balanced with synthetic air. For isotopic biases on CO2 measurements, we compared experimental results and theoretical calculations, which showed excellent agreement within their uncertainty. We derived instrument-specific water correction functions empirically for three WS-CRDS instruments (Picarro EnviroSense 3000i, G-1301, and G-2301), and evaluated the transferability of the water correction function from G-1301 among these instruments. Although the transferability was not proven, no significant difference was found in the water vapor correction function for the investigated WS-CRDS instruments as well as the instruments reported in the past studies within the typical analytical precision at sufficiently low water concentrations (<0.7% for CO2 and <0.6% for CH4). For accurate measurements of CO2 and CH4 in ambient air, we concluded that WS-CRDS measurements should be performed under complete dehumidification of air samples, or moderate dehumidification followed by application of a water vapor correction function, along with calibration by natural air-based standard gases or purified air-balanced synthetic standard gases with the isotopic correction.

  18. Fiber-ring laser-based intracavity photoacoustic spectroscopy for trace gas sensing.

    PubMed

    Wang, Qiang; Wang, Zhen; Chang, Jun; Ren, Wei

    2017-06-01

    We demonstrated a novel trace gas sensing method based on fiber-ring laser intracavity photoacoustic spectroscopy. This spectroscopic technique is a merging of photoacoustic spectroscopy (PAS) with a fiber-ring cavity for sensitive and all-fiber gas detection. A transmission-type PAS gas cell (resonant frequency f0=2.68  kHz) was placed inside the fiber-ring laser to fully utilize the intracavity laser power. The PAS signal was excited by modulating the laser wavelength at f0/2 using a custom-made fiber Bragg grating-based modulator. We used this spectroscopic technique to detect acetylene (C2H2) at 1531.6 nm as a proof of principle. With a low Q-factor (4.9) of the PAS cell, our sensor achieved a good linear response (R2=0.996) to C2H2 concentration and a minimum detection limit of 390 ppbv at 2-s response time.

  19. Detecting and Eliminating Interfering Organic Compounds in Waters Analyzed for Isotopic Composition by Crds

    NASA Astrophysics Data System (ADS)

    Richman, B. A.; Hsiao, G. S.; Rella, C.

    2010-12-01

    Optical spectroscopy based CRDS technology for isotopic analysis of δD and δ18O directly from liquid water has greatly increased the number and type of liquid samples analyzed. This increase has also revealed a previously unrecognized sample contamination problem. Recently West[1] and Brand[2] identified samples containing ethanol, methanol, plant extracts and other organic compounds analyzed by CRDS and other spectroscopy based techniques as yielding erroneous results for δD and δ18O (especially δD) due to spectroscopic interference. Not all organic compounds generate interference. Thus, identifying which samples are contaminated by which organic compounds is of key importance for data credibility and correction. To address this problem a new approach in the form of a software suite, ChemCorrect™, has been developed. A chemometrics component uses a spectral library of water isotopologues and interfering organic compounds to best fit the measured spectra. The best fit values provide a quantitative assay of the actual concentrations of the various species and are then evaluated to generate a visual flag indicating samples affected by organic contamination. Laboratory testing of samples spiked with known quantities of interfering organic compounds such as methanol, ethanol, and terpenes was performed. The software correctly flagged and identified type of contamination for all the spiked samples without any false positives. Furthermore the reported values were a linear function of actual concentration with an R^2>0.99 even for samples which contained multiple organic compounds. Further testing was carried out against a range of industrial chemical compounds which can contaminate ground water as well as a variety of plant derived waters and juices which were also analyzed by IRMS. The excellent results obtained give good insight into which organic compounds cause interference and which classes of plants are likely to contain interfering compounds. Finally approaches to minimize the effect of interfering compounds will be discussed including methods to assess the confidence level of an isotopic value obtained from a contaminated sample. [1] Rapid Commun. Mass Spectrom. 2010; 24: 1-7 [2] Rapid Commun. Mass Spectrom. 2009; 23: 1879-1884 Results from laboratory samples, most of which were spiked with interfering organic compounds. Samples are color coded as follows: blue=standard, green=no contamination, yellow=slight contamination, red=heavily contaminated.

  20. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    PubMed

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  1. The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation

    PubMed Central

    Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt

    2010-01-01

    Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.

  2. Gait COP trajectory of left side hip-dislocation and scoliotic patient using ankle-foot orthoses

    NASA Astrophysics Data System (ADS)

    Chong, Albert K.; Alrikabi, Redha; Milburn, Peter

    2017-07-01

    Plantar pressure-sensing mats and insole plantar sensor pads are ideal low-cost alternatives to force plates for capturing plantar COP excursion during gait. The acquired COP traces, in the form of pedobarographic images are favored by many clinicians and allied health professionals for evaluation of foot loading and balance in relation to foot biomechanics, foot injury, foot deformation, and foot ulceration. Researchers have recommended the use of COP trace for the biomechanical study of the deformed foot and lower-limb to improve orthosis design and testing. A correctly designed orthoses improves mobility and reduces pain in the foot, lower limb and lower spine region during gait. The research was carried out to evaluate the performance of two types of orthosis, namely: a custom-molded orthosis and an over-the-counter molded orthosis to determine the quality of gait of an adult scoliotic patient. COP trace patterns were compared with those of a healthy adult and showed the design of the custom-molded orthosis resulted in an improved quality of movements and provided enhanced stability for the deformed left foot during gait.

  3. Quartz enhanced photoacoustic H{sub 2}S gas sensor based on a fiber-amplifier source and a custom tuning fork with large prong spacing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Hongpeng; Liu, Xiaoli; Zheng, Huadan

    2015-09-14

    A quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplified laser source and a custom quartz tuning fork (QTF) with its two prongs spaced ∼800 μm apart, is reported. The sensor employs an acoustic micro-resonator (AmR) which is assembled in an “on-beam” QEPAS configuration. Both length and vertical position of the AmR are optimized in terms of signal-to-noise ratio, significantly improving the QEPAS detection sensitivity by a factor of ∼40, compared to the case of a sensor using a bare custom QTF. The fiber-amplifier-enhanced QEPAS sensor is applied to H{sub 2}S trace gas detection, reaching a sensitivity of ∼890 ppbmore » at 1 s integration time, similar to those obtained with a power-enhanced QEPAS sensor equipped with a standard QTF, but with the advantages of easy optical alignment, simple installation, and long-term stability.« less

  4. Precise oxygen and hydrogen isotope determination in nanoliter quantities of speleothem inclusion water by cavity ring-down spectroscopic techniques

    NASA Astrophysics Data System (ADS)

    Uemura, Ryu; Nakamoto, Masashi; Asami, Ryuji; Mishima, Satoru; Gibo, Masakazu; Masaka, Kosuke; Jin-Ping, Chen; Wu, Chung-Che; Chang, Yu-Wei; Shen, Chuan-Chou

    2016-01-01

    Speleothem inclusion-water isotope compositions are a promising new climatic proxy, but their applicability is limited by their low content in water and by analytical challenges. We have developed a precise and accurate isotopic technique that is based on cavity ring-down spectroscopy (CRDS). This method features a newly developed crushing apparatus, a refined sample extraction line, careful evaluation of the water/carbonate adsorption effect. After crushing chipped speleothem in a newly-developed crushing device, released inclusion water is purified and mixed with a limited amount of nitrogen gas in the extraction line for CRDS measurement. We have measured 50-260 nL of inclusion water from 77 to 286 mg of stalagmite deposits sampled from Gyokusen Cave, Okinawa Island, Japan. The small sample size requirement demonstrates that our analytical technique can offer high-resolution inclusion water-based paleoclimate reconstructions. The 1σ reproducibility for different stalagmites ranges from ±0.05 to 0.61‰ for δ18O and ±0.0 to 2.9‰ for δD. The δD vs. δ18O plot for inclusion water from modern stalagmites is consistent with the local meteoric water line. The 1000 ln α values based on calcite and fluid inclusion measurements from decades-old stalagmites are in agreement with the data from present-day farmed calcite experiment. Combination of coeval carbonate and fluid inclusion data suggests that past temperatures at 9-10 thousand years ago (ka) and 26 ka were 3.4 ± 0.7 °C and 8.2 ± 2.4 °C colder than at present, respectively.

  5. Continuous-flow water sampler for real-time isotopic water measurements

    NASA Astrophysics Data System (ADS)

    Carter, J.; Dennis, K.

    2013-12-01

    Measuring the stable isotopes of liquid water (δ18O and δD) is a tool familiar to many Earth scientists, but most current techniques require discrete sampling. For example, isotope ratio mass spectrometry requires the collection of aliquots of water that are then converted to CO2, CO or H2 for analysis. Similarly, laser-based techniques, such as Cavity Ring-Down Spectroscopy (CRDS) convert discrete samples (typically < 2μL) of liquid water to water vapor using a flash vaporization process. By requiring the use of discrete samples fine-scale spatial and temporal studies of changes in δ18O and δD are limited. Here we present a continuous-flow water sampler that will enable scientists to probe isotopic changes in real-time, with applications including, but not limited to, quantification of the 'amount effect' (Dansgaard, 1964) during an individual precipitation event or storm track, real-time mixing of water in river systems, and shipboard continuous water measurements (Munksgaard et al., 2012). Due to the inherent ability of CRDS to measure a continuous flow of water vapor it is an ideal candidate for interfacing with a continuous water sampling system. Here we present results from the first commercially available continuous-flow water sampler, developed by engineers at Picarro. This peripheral device is compatible with Picarro CRDS isotopic water analyzers, allowing real-time, continuous isotopic measurements of liquid water. The new device, which expands upon the design of Munskgaard et al. (2011), utilizes expanded polytetrafluoroethylene (ePTFE) membrane technology to continuously generate gas-phase water, while liquid water is pumped through the system. The water vapor subsequently travels to the CRDS analyzer where the isotopic ratios are measured and recorded. The generation of water vapor using membrane technology is sensitive to environmental conditions, which if not actively control, lead to sustainable experimental noise and drift. Consequently, our continuous-flow water sample employs active control for all pertinent parameters, significantly increasing its stability and usability. We will present data from controlled laboratory experiments demonstrating sample-to-sample precision and long-term stability. We will also show experimental data that highlights the instrumental sample-to-sample memory, which we have decreased significantly from previous implementations of this technology. Additionally, we will present field results from the Sacramento River, CA. Dansgaard, W. (1964) 'Stable isotopes in precipitation', Tellus, 16(4), p. 436-468. Munksgaard, N.C., Wurster, C.M., Bass, A., Zagorskis, I., and Bird, M.I. (2012) 'First continuous shipboard d18O and dD measurements in seawater by diffusion sampling--cavity ring-down spectrometry', Environmental Chemistry Letters, 10, p.301-307. Munksgaard, N.C., Wurster, C.M., and Bird, M.I., (2011), 'Continuous analysis of δ18O and δD values of water by diffusion sampling cavity ring-down spectrometry: a novel sampling device for unattended field monitoring of precipitation, ground and surface waters', Rapid Communications in Mass Spectrometry, 25, p. 3706-3712.

  6. Modification of a commercial cavity ring-down spectroscopy NO{sub 2} detector for enhanced sensitivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castellanos, Patricia; Ehrman, Sheryl H.; Luke, Winston T.

    Nitrogen dioxide (NO{sub 2}) plays a central role in atmospheric chemistry, air pollution, and biogeochemical cycles. Many analytical techniques have been developed to detect NO{sub 2}, but only chemiluminescence-based instruments are commonly, commercially available. There remains a need for a fast, light, and simple method to directly measure NO{sub 2}. In this work we describe the modification and characterization of a small, commercially available cavity ring-down spectroscopy (CRDS) NO{sub 2} detector suitable for surface and aircraft monitoring. A metal oxide scrubber was added to remove NO{sub 2}, and provide a chemical zero, improving the detection limit (3{sigma} of the backgroundmore » noise) from several parts per billion by volume (ppbv) to 0.06 ppbv, integrated over 60 s. Known interferences by water and particles were removed using Nafion tubing and a 1 {mu}m Teflon filter, respectively. A 95% response time of 18{+-}1 s was observed for a step change in concentration. The CRDS detector was run in parallel to an ozone chemiluminescence device with photolytic conversion of NO{sub 2} to NO. The two instruments measured ambient air in suburban Maryland. A least-squares fit to the comparison data resulted a slope of 0.960{+-}0.002 and R of 0.995, showing agreement within experimental uncertainty.« less

  7. High-resolution Measurements of Gas-Phase Hydrogen Chloride (HCl) in the Atmosphere by Cavity Ring Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hoffnagle, John; Chen, Hongbing; Lee, Jim; Rella, Chris; Kim-Hak, David; Winkler, Renato; Markovic, Milos; Veres, Patrick

    2017-04-01

    Halogen radical species, such as chlorine and bromine atoms and their oxides, can greatly affect the chemical composition of the troposphere. Hydrogen chloride is the dominant (gas-phase) contributor to the tropospheric chlorine inventory. Real time in situ observations of HCl can provide an important window into the complex photochemical reaction pathways for chlorine in the atmosphere, including heterogeneous reactions on aerosol surfaces. In this work, we report a novel, commercially-available HCl gas-phase analyzer (G2108, Picarro Inc. Santa Clara, CA, USA) based upon Cavity Ring Down Spectroscopy (CRDS) in the near-infrared, and discuss its performance. With a measurement interval of approximately 2 seconds, a precision of better than 40 parts-per-trillion (1 sigma, 30 seconds), and a response time of approximately 1-2 minutes (10 - 90% rise time or 90 - 10% fall time), this analyzer is well-suited for measurements of atmospherically-relevant concentrations of HCl, in both laboratory and field. CRDS provides very stable measurements and low drift, requiring infrequent calibration of the instrument, and can therefore be operated remotely for extended periods of time. In this work we also present results from a laboratory intercomparison of the Picarro G2108 analyzer and an iodide ion time-of-flight Chemical Ionization Mass Spectrometer (CIMS), and the results of the analyzer time response tests.

  8. Doppler Broadening Thermometry Based on Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Sun, Yu Robert; Cheng, Cunfeng; Tao, Lei-Gang; Tan, Yan; Kang, Peng; Liu, An-Wen; Hu, Shui-Ming

    2016-06-01

    A Doppler broadening thermometry (DBT) instrument is implemented based on a laser-locked cavity ring-down spectrometer. [1,2] It can be used to determine the Boltzmann constant by measuring the Doppler width of a molecular ro-vibrational transition in the near infrared. Compared with conventional direct absorption methods, the high-sensitivity of CRDS allows to reach satisfied precision at lower sample pressures, which reduces the influence due to collisions. By measuring the ro-vibrational transition of C_2H_2 at 787 nm, we demonstrate a statistical uncertainty of 6 ppm (part per million) in the determined linewidth by several hours' measurement at a sample pressure of 1.5 Pa. [3] However, the complicity in the spectrum of a polyatomic molecule induces potential systematic influence on the line profile due to nearby ``hidden'' lines from weak bands or minor isotopologues. Recently, the instrument has been upgraded in both sensitivity and frequency accuracy. A narrow-band fiber laser frequency-locked to a frequency comb is applied, and overtone transitions at 1.56 μm of the 12C16O molecule are used in the CRDS-DBT measurements. The simplicity of the spectrum of the diatomic CO molecule eliminates the potential influence from ``hidden'' lines. Our preliminary measurements and analysis show that it is feasible to pursue a DBT measurement toward the 1 ppm precision. H. Pan, et al., Rev. Sci. Instrum. 82, 103110 (2011) Y. R. Sun, et al., Opt. Expr., 19, 19993 (2011) C.-F. Cheng, et al., Metrologia, 52, S385 (2015)

  9. Space crew radiation exposure analysis system based on a commercial stand-alone CAD system

    NASA Technical Reports Server (NTRS)

    Appleby, Matthew H.; Golightly, Michael J.; Hardy, Alva C.

    1992-01-01

    Major improvements have recently been completed in the approach to spacecraft shielding analysis. A Computer-Aided Design (CAD)-based system has been developed for determining the shielding provided to any point within or external to the spacecraft. Shielding analysis is performed using a commercially available stand-alone CAD system and a customized ray-tracing subroutine contained within a standard engineering modeling software package. This improved shielding analysis technique has been used in several vehicle design projects such as a Mars transfer habitat, pressurized lunar rover, and the redesigned Space Station. Results of these analyses are provided to demonstrate the applicability and versatility of the system.

  10. The performance of child restraint devices in transport airplane passenger seats.

    DOT National Transportation Integrated Search

    1994-09-01

    The performance of child restraint devices (CRDs) in commercial transport airplane passenger seats was evaluated by a dynamic impact test program. Background information on the policies and regulations related to child restraints is summarized. Tests...

  11. On-line Differential Thermal Isotope Analysis: A New Method for Measuring Oxygen and Hydrogen Isotopes of Hydration Water in Minerals

    NASA Astrophysics Data System (ADS)

    Bauska, T.; Hodell, D. A.; Walters, G.

    2016-12-01

    Oxygen (16O,17O,18O) and hydrogen (H,D) isotopes of hydration water in minerals provide a rich source of information about the conditions under which hydrated minerals form on Earth and other planetary bodies (e.g. Mars). We have developed a new method for measuring different types of bonded water (e.g., molecular, hydroxyl) contained in hydrated minerals by coupling a thermal gravimeter (TG) and a cavity ringdown laser spectrometer (CRDS). The method involves step heating a mineral sample, precisely measuring the weight loss and enthalpy as the sample undergoes dehydration and dehydroxylation, whilst simultaneously determining the oxygen and hydrogen isotopes of the water vapor evolved from the mineral sample by cavity ring-down laser spectroscopy (CRDS). Nitrogen carrier gas is used to transfer the sample from the TG to the CRDS via a heated line and interface box. The interface includes the capability of (i) cryogenic trapping discrete types of water for samples containing small amounts of water; (ii) injecting small quantities of water of known isotopic value for calibration; and (iii) converting volatile organic compounds to nascent amounts of water using a catalyst. The CRDS continually measures water vapor concentration in the optical cavity and hydrogen and oxygen isotope ratios. Isotopic values are calculated by integrating the product of the water amount and its isotopic value for the separated peaks after correcting for background. Precision of the method was estimated by comparing isotope results of total water for gypsum measured by DTIA with our conventional method of extraction and analysis (Gázquez et al., 2015. Rapid Communications in Mass Spectrometry, 29, 1997-2006). Errors for the isotopic values of total hydration water vary between ±0.08 and ±0.34 ‰ for δ18O and between ±0.16 and ±0.86 ‰ for δD. We demonstrate the application of the DTIA method to a variety of hydrous minerals and mineraloids including gypsum, clays, and amorphous silica (opal, glass, chert). The DTIA method has wide ranging application for addressing fundamental problems across many disciplines in Earth and Planetary Sciences, including: paleoclimatology, sedimentology, volcanology, water exchange between the solid earth and hydrosphere, and water on Mars and other planetary bodies.

  12. Long-term greenhouse gas measurements from aircraft

    NASA Astrophysics Data System (ADS)

    Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.

    2012-10-01

    In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. NOAA has installed window-replacement inlet plates on two USCG C-130 aircraft and deploys a pallet with NOAA instrumentation on each ADA flight. Flights typically last 8 h and cover a very large area, traveling from Kodiak, AK in the south up to Barrow, AK in the north, and making altitude profiles near the coast as well as in the interior. NOAA instrumentation on each flight includes: a flask sampling system, a continuous CO2/CH4/CO/H2O analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. GPS time and location from the aircraft's navigation system are also collected. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. Instruments on this aircraft are designed and deployed to be able to collect air samples and data autonomously, so that NOAA personnel visit the site only for installation at the beginning of each season. We present an assessment of the cavity ring-down spectroscopy (CRDS) CO2/CH4/CO/H2O analyzer performance operating on an aircraft over a three-year period. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction. Short and long-term stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 5 ppb for CO2, CH4, CO respectively, considering differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving biases in the comparison between flasks and in-situ CRDS measurements.

  13. Development and Evaluation of a Spectral Analysis Method to Eliminate Organic Interference with Cavity Ring-Down Measurements of Water Isotope Ratios.

    NASA Astrophysics Data System (ADS)

    Lin, Z.; Kim-Hak, D.; Popp, B. N.; Wallsgrove, N.; Kagawa-Viviani, A.; Johnson, J.

    2017-12-01

    Cavity ring-down spectroscopy (CRDS) is a technology based on the spectral absorption of gas molecules of interest at specific spectral regions. The CRDS technique enables the analysis of hydrogen and oxygen stable isotope ratios of water by directly measuring individual isotopologue absorption peaks such as H16OH, H18OH, and D16OH. Early work demonstrated that the accuracy of isotope analysis by CRDS and other laser-based absorption techniques could be compromised by spectral interference from organic compounds, in particular methanol and ethanol, which can be prevalent in ecologically-derived waters. There have been several methods developed by various research groups including Picarro to address the organic interference challenge. Here, we describe an organic fitter and a post-processing algorithm designed to improve the accuracy of the isotopic analysis of the "organic contaminated" water specifically for Picarro models L2130-i and L2140-i. To create the organic fitter, the absorption features of methanol around 7200 cm-1 were characterized and incorporated into spectral analysis. Since there was residual interference remaining after applying the organic fitter, a statistical model was also developed for post-processing correction. To evaluate the performance of the organic fitter and the postprocessing correction, we conducted controlled experiments on the L2130-i for two water samples with different isotope ratios blended with varying amounts of methanol (0-0.5%) and ethanol (0-5%). When the original fitter was not used for spectral analysis, the addition of 0.5% methanol changed the apparent isotopic composition of the water samples by +62‰ for δ18O values and +97‰ for δ2H values, and the addition of 5% ethanol changed the apparent isotopic composition by -0.5‰ for δ18O values and -3‰ for δ2H values. When the organic fitter was used for spectral analysis, the maximum methanol-induced errors were reduced to +4‰ for δ18O values and +5‰ for δ2H values, and the maximum ethanol-induced errors were unchanged. When the organic fitter was combined with the post-processing correction, up to 99.8% of the total methanol-induced errors and 96% of the total ethanol-induced errors could be corrected. The applicability of the algorithm to natural samples such as plant and soil waters will be investigated.

  14. CDC Vital Signs: Safer Food Saves Lives

    MedlinePlus

    ... trace foods from source to destination. Use store loyalty card and distribution records to help investigators identify what made people sick. Recall products linked to an outbreak and notify customers. Choose only suppliers that use food safety best ...

  15. True eddy accumulation and eddy covariance methods and instruments intercomparison for fluxes of CO2, CH4 and H2O above the Hainich Forest

    NASA Astrophysics Data System (ADS)

    Siebicke, Lukas

    2017-04-01

    The eddy covariance (EC) method is state-of-the-art in directly measuring vegetation-atmosphere exchange of CO2 and H2O at ecosystem scale. However, the EC method is currently limited to a small number of atmospheric tracers by the lack of suitable fast-response analyzers or poor signal-to-noise ratios. High resource and power demands may further restrict the number of spatial sampling points. True eddy accumulation (TEA) is an alternative method for direct and continuous flux observations. Key advantages are the applicability to a wider range of air constituents such as greenhouse gases, isotopes, volatile organic compounds and aerosols using slow-response analyzers. In contrast to relaxed eddy accumulation (REA), true eddy accumulation (Desjardins, 1977) has the advantage of being a direct method which does not require proxies. True Eddy Accumulation has the potential to overcome above mentioned limitations of eddy covariance but has hardly ever been successfully demonstrated in practice in the past. This study presents flux measurements using an innovative approach to true eddy accumulation by directly, continuously and automatically measuring trace gas fluxes using a flow-through system. We merge high-frequency flux contributions from TEA with low-frequency covariances from the same sensors. We show flux measurements of CO2, CH4 and H2O by TEA and EC above an old-growth forest at the ICOS flux tower site "Hainich" (DE-Hai). We compare and evaluate the performance of the two direct turbulent flux measurement methods eddy covariance and true eddy accumulation using side-by-side trace gas flux observations. We further compare performance of seven instrument complexes, i.e. combinations of sonic anemometers and trace gas analyzers. We compare gas analyzers types of open-path, enclosed-path and closed-path design. We further differentiate data from two gas analysis technologies: infrared gas analysis (IRGA) and laser spectrometry (open path and CRDS closed-path laser spectrometers). We present results of CO2 and H2O fluxes from the following six instruments, i.e. combinations of sonic anemometers/gas analyzers (and methods): METEK-uSonic3/Picarro-G2301 (TEA), METEK-uSonic3/LI-7500 (EC), Gill-R3/LI-6262 (EC), Gill-R3/LI-7200 (EC), Gill-HS/LI-7200 (EC), Gill-R3/LGR-FGGA (EC). Further, we present results of much more difficult to measure CH4 fluxes from the following three instruments, i.e. combinations of sonic anemometers/gas analyzers (and methods): METEK-uSonic3/Picarro-G2301 (TEA), Gill-R3/LI-7700 (EC), Gill-R3/LGR-FGGA (EC). We observed that CO2, CH4 and H2O fluxes from the side-by-side measurements by true eddy accumulation and eddy covariance methods correlated well. Secondly, the difference between the TEA and EC methods using the same sonic anemometer but different gas analyzer was often smaller than the mismatch of the various side-by-side eddy covariance measurements using different sonic anemometers and gas analyzers. Signal-to-noise ratios of CH4 fluxes from the true eddy accumulation system system were superior to both eddy covariance sensors (open-path LI-7700 and closed-path CRDS LGR-FGGA sensors). We conclude that our novel implementation of the true eddy accumulation method demonstrated high signal-to-noise ratios, applicability to slow-response gas analyzers, small power consumption and direct proxy-free ecosystem-scale trace gas flux measurements of CO2, CH4 and H2O. The current results suggest that true eddy accumulation would be suitable and should be applied as the method-of-choice for direct flux measurements of a large number of atmospheric constituents beyond CO2 and H2O, including isotopes, aerosols, volatile organic compounds and other trace gases for which eddy covariance might not be a viable alternative. We will further develop true eddy accumulation as a novel approach using multiplexed systems for spatially distributed flux measurements.

  16. The IAGOS GHG package: a measurement system for continuous airborne observations of CO2, CH4, H2O and CO

    NASA Astrophysics Data System (ADS)

    Gerbig, C.; Filges, A.; Franke, H.; Klaus, C.; Chen, H.

    2012-12-01

    A cavity ring-down spectroscopy (CRDS) based measurement system for greenhouse gases was designed, tested, and qualified for deployment on commercial airliners within the IAGOS-ERI (In-service Aircraft for a Global Observing System - European Research Infrastructure) project. The design meets requirements regarding physical dimensions (size, weight), performance (long term stability, low maintenance, robustness, full automation) and safety issues (fire prevention regulations). The system uses components of a commercially available CRDS instrument (G2401-m, Picarro Inc.) integrated in a frame suitable for integration in the avionics bay of the Airbus A-340. The first of the IAGOS GHG packages is scheduled for integration in early 2013. The aim is to have seven systems operational within four years, providing for long-term GHG observations with near-global coverage. To enable robust and automated operation of the IAGOS GHG package over six-month deployment periods, numerous technical issues had to be addressed. An inlet system, designed as virtual impactor to eliminate sampling of larger aerosols, ice particles, and water droplets, and provides additional positive ram-pressure. In combination with a lowered sample flow of 0.1 slpm, this ensures a fully controlled sample pressure in the cavity of 140 torr throughout the aircraft altitude operating range up to 12.5 km without the need of an upstream sampling pump. Furthermore, no sample drying is required, as the simultaneously measured water vapor mole fraction is used to correct for dilution and spectroscopic effects. This also enables the collection of science-quality water vapor measurements throughout the atmosphere. To allow for trace gas measurements to be fully traceable to WMO scales, a two-standard calibration system has been designed and tested that periodically provides calibration gas to the instrument during flight and on ground. A targeted six-month deployment cycle followed by maintenance of the package ensures a safe operation. During maintenance, calibration gases are analysed and replenished, and a functional inspection, followed by replacement of depleted or damaged parts, will be undertaken. Spare instrumentation will be used to provide for year-round GHG measurements on board each aircraft. We present results from recent test flights and laboratory tests that document the performance for GHG and water vapor measurements. Furthermore, future applications of the IAGOS-GHG data stream, provided in near-real-time via SatCom to the weather prediction centres, will be discussed, including the improved estimation of GHG budgets at regional to continental scales, the assessment of vertical transport in atmospheric models through comparison with observed vertical tracer distributions, and the validation of remote sensing measurements of GHGs.

  17. Patterns of Body Composition Relating to Chronic Respiratory Diseases Among Adults in Four Resource-Poor Settings in Peru.

    PubMed

    Trompeter, Grace; Grigsby, Matthew R; Miele, Catherine H; Wise, Robert A; Gilman, Robert H; Miranda, J Jaime; Bernabe-Ortiz, Antonio; Checkley, William

    2018-06-01

    Body composition is known to influence the development and progression of chronic respiratory diseases (CRDs). We sought to characterize the unique anthropometric phenotypes that present with asthma, chronic obstructive pulmonary disease (COPD), and chronic bronchitis across four distinct settings in Peru. We collected sociodemographic, clinical history, and spirometry data from 2959 participants from Lima, Tumbes, and rural and urban Puno. We compared the prevalence of CRDs among different study sites and described disease phenotypes. We used single and multivariable linear regression to model the influence of CRD status on various descriptors of body composition. Overall prevalence of CRDs varied across sites with the highest prevalence of asthma in Lima (14.5%) and the highest prevalence of COPD in rural Puno (9.9%). Measures of body composition also varied across sites, with highest mean body mass index (BMI) in Lima (28.4 kg/m 2 ) and the lowest mean BMI in rural Puno (25.2 kg/m 2 ). Participants with COPD had the lowest mean fat mass index (FMI) (10.5 kg/m 2 ) and waist circumference (88.3 cm), whereas participants with asthma had the highest mean FMI (14.5 kg/m 2 ), and waist circumference (94.8 cm). In multivariable analysis, participants with COPD had a lower waist circumference (adjusted mean - 2.97 cm, 95% CI 4.62 to - 1.32 cm) when compared to non-CRD participants. Our findings provide evidence that asthma and chronic bronchitis are more likely to be associated with obesity and higher fat mass, while COPD is associated with being underweight and having less lean mass.

  18. Major Chronic Respiratory Diseases in Chiang Mai: Prevalence, Clinical Characteristics, and Their Correlations.

    PubMed

    Pothirat, Chaicharn; Phetsuk, Nittaya; Liwsrisakun, Chalerm; Bumroongkit, Chaiwat; Deesomchok, Athavudh; Theerakittikul, Theerakorn

    2016-09-01

    To identify the prevalence, clinical characteristics, disease severity, and correlations of major chronic respiratory diseases (CRDs) among the adult population living in Chiang Mai. A cross-sectional study was conducted with adults living in municipal areas of Chiang Mai. All clinical relevant data collected by face-to-face interview was confirmed by pulmonologists. The chest radiographic findings and post-bronchodilator spirometry were done in all subjects. The aeroallergen skin test and rhinoscopy were performed in all chronic rhinitis and asthma subjects. Five hundred seventy four subjects with mean age 52.9±10.0 years, 59.6% female, and 37.5% smokers were recruited. The prevalence of overall CRDs was 59.2%. Chronic rhinitis was the most prevalent chronic respiratory disease (n = 239, 41.6%), followed by asthma (n = 58, 10.1%), and chronic obstructive pulmonary disease (COPD) (n = 21, 3.7%). The most common abnormal pulmonary function test was restrictive lung disorders (n = 53, 9.6%). Asthma subjects were determined to be more allergic than chronic rhinitis subjects (58.1% vs. 39.9%, p-value = 0.033). Regarding the disease severity, 14.9% of chronic rhinitis and 10.3% of asthma subjects were classified as moderate to severe degree, whereas 81% of chronic obstructive pulmonary disease subjects were classified as moderate to very severe degrees. In asthma patients, there were positive association with chronic rhinitis (OR 3.9, 95% CI 2.1-7.0, p-value <0.001). The prevalence of major CRDs in adults among Chiang Mai population was significantly high with overlapped respiratory symptoms and varying disease severity. Additionally, chronic rhinitis had correlation with asthma but not with COPD.

  19. Isotope Ratio Mass Spectrometry and Shale Gas - What Is Possible with Current Technology?

    NASA Astrophysics Data System (ADS)

    Barrie, C. D.; Kasson, A.

    2014-12-01

    With ever increasing exploration and exploitation of 'unconventional' hydrocarbon resources, the drive to understand the origins, history and importance of these resources and their effects on the surrounding environment (i.e. ground waters) has never been more important. High-throughput, high-precision isotopic measurements are therefore a key tool in this industry to both understand the gas generated and monitor the development and stability of wells through time. With the advent of cavity ringdown spectroscopy (CRDS) instrumentation, there has been a push in some applications - environmental & atmospheric - to gather more and more data directly at the location of collection or at dedicated field stations. Furthermore, CRDS has resulted in users seeking greater autonomy of instrumentation and so-called black box technology. Traditionally IRMS technology has not met any of these demands, requiring very specific and extensive footprint, power and environmental requirements. This has meant that the 'Oil & Gas' sector, which for natural gases measurements requires GC-IRMS technology - not possible via CRDS - loses time, money and manpower as samples get sent to central facility or contract labs with potentially long lee times. However, recent developments in technology mean that IRMS systems exist which are benchtop, have much lower power requirements, standard power connections and as long as housed in a temperature controlled field stations can be deployed anywhere. Furthermore, with advances in electronics and software IRMS systems are approaching the black box level of newer instrumentation while maintaining the flexibility and abilities of isotope ratio mass spectrometry. This presentation will outline changes in IRMS technology applicable to the Oil & Gas industry, discuss the feasibility of true 'field' deployability and present results from a range of Oil & Gas samples.

  20. Access to essential medicines to treat chronic respiratory disease in low-income countries.

    PubMed

    Bissell, K; Perrin, C; Beran, D

    2016-06-01

    Chronic respiratory diseases (CRDs) affect hundreds of millions of people. The United Nations 2011 meeting on non-communicable diseases (NCDs) marked a turning point in addressing this burden. The targets established following this meeting incorporated specific measures to address the availability and affordability of essential medicines. These are aligned with the sustainable development goals (SDGs) and the push for universal health coverage. However, essential medicines for CRDs remain unaffordable and unavailable to many. For asthma, the availability of medicines was respectively 30.1% and 43.1% in the public and private sectors. The maximum annual costs of treatment were US$102.10 for beclometasone, US$82.99 for salbutamol and US$1501.79 for budesonide, representing respectively 40%, 15% and 209% of per capita income in Malawi, Burkina Faso and Guinea. Multiple factors contribute to poor availability and affordability. Experience from human immunodeficiency virus/acquired immune-deficiency syndrome shows that medicines and care can be delivered in low-income countries and among the NCDs. A unique example of an effective mechanism for providing access to affordable essential CRD medicines is the Asthma Drug Facility. Working on the six health system building blocks proposed by the World Health Organization can help countries address not only problems regarding access to medicines, but also those hampering adequate care. Improving medicine supply systems, training, national guidelines, financing, research, data utilisation and models of care at the primary health care level will help. A CRD target (e.g., 50% reduction in asthma hospitalisations) as well as the use of asthma as a measure for health system effectiveness and CRDs as a tracer for SDGs would help focus global, national and local leadership.

  1. Gas chromatographic analysis of trace impurities in chlorine trifluoride.

    PubMed

    Laurens, J B; Swinley, J M; de Coning, J P

    2000-03-24

    The gas chromatographic determination of trace gaseous impurities in highly reactive fluorinated gaseous matrices presents unique requirements to both equipment and techniques. Especially problematic are the gases normally present in ambient air namely oxygen and nitrogen. Analysing these gases at the low microl/l (ppm) level requires special equipment and this publication describes a custom-designed system utilising backflush column switching to protect the columns and detectors. A thermal conductivity detector with nickel filaments was used to determine ppm levels of impurities in ClF3.

  2. Cavity ring-down spectroscopy (CRDS) system for measuring atmospheric mercury using differential absorption

    NASA Astrophysics Data System (ADS)

    Pierce, A.; Obrist, D.; Moosmuller, H.; Moore, C.

    2012-04-01

    Atmospheric elemental mercury (Hg0) is a globally pervasive element that can be transported and deposited to remote ecosystems where it poses — particularly in its methylated form — harm to many organisms including humans. Current techniques for measurement of atmospheric Hg0 require several liters of sample air and several minutes for each analysis. Fast-response (i.e., 1 second or faster) measurements would improve our ability to understand and track chemical cycling of mercury in the atmosphere, including high frequency Hg0 fluctuations, sources and sinks, and chemical transformation processes. We present theory, design, challenges, and current results of our new prototype sensor based on cavity ring-down spectroscopy (CRDS) for fast-response measurement of Hg0 mass concentrations. CRDS is a direct absorption technique that implements path-lengths of multiple kilometers in a compact absorption cell using high-reflectivity mirrors, thereby improving sensitivity and reducing sample volume compared to conventional absorption spectroscopy. Our sensor includes a frequency-doubled, dye-laser emitting laser pulses tunable from 215 to 280 nm, pumped by a Q-switched, frequency tripled Nd:YAG laser with a pulse repetition rate of 50 Hz. We present how we successfully perform automated wavelength locking and stabilization of the laser to the peak Hg0 absorption line at 253.65 nm using an external isotopically-enriched mercury (202Hg0) cell. An emphasis of this presentation will be on the implementation of differential absorption measurement whereby measurements are alternated between the peak Hg0 absorption wavelength and a nearby wavelength "off" the absorption line. This can be achieved using a piezo electric tuning element that allows for pulse-by-pulse tuning and detuning of the laser "online" and "offline" of the Hg absorption line, and thereby allows for continuous correction of baseline extinction losses. Unexpected challenges with this approach included different efficiencies of laser performance (e.g., frequency doubling) at the two wavelengths and temperature dependence. We will discuss improvements on the control of our system to eliminate drift due to conversion efficiency and temperature dependence. We will detail complications with operating this instrument from a mobile platform for in situ measurements in the field. Finally, we will present data acquisition and processing approaches along with results of calibration curves, and comparisons to conventional mercury analyzers (i.e., a Tekran 2537 mercury vapor analyzer) during ambient air measurements.

  3. Child restraint device use and misuse in Michigan

    DOT National Transportation Integrated Search

    1997-09-01

    In 1994, nearly 87,000 children under the age of five were injured or killed in traffic crashes across the nation, with 2,336 of these injuries and fatalities occurring in Michigan. The use of child restraint devices (CRDs, also called child safety s...

  4. Comprehensive laboratory and field testing of cavity ring-down spectroscopy analyzers measuring H2O, CO2, CH4 and CO

    NASA Astrophysics Data System (ADS)

    Yver Kwok, C.; Laurent, O.; Guemri, A.; Philippon, C.; Wastine, B.; Rella, C. W.; Vuillemin, C.; Truong, F.; Delmotte, M.; Kazan, V.; Darding, M.; Lebègue, B.; Kaiser, C.; Xueref-Rémy, I.; Ramonet, M.

    2015-09-01

    To develop an accurate measurement network of greenhouse gases, instruments in the field need to be stable and precise and thus require infrequent calibrations and a low consumption of consumables. For about 10 years, cavity ring-down spectroscopy (CRDS) analyzers have been available that meet these stringent requirements for precision and stability. Here, we present the results of tests of CRDS instruments in the laboratory (47 instruments) and in the field (15 instruments). The precision and stability of the measurements are studied. We demonstrate that, thanks to rigorous testing, newer models generally perform better than older models, especially in terms of reproducibility between instruments. In the field, we see the importance of individual diagnostics during the installation phase, and we show the value of calibration and target gases that assess the quality of the data. Finally, we formulate recommendations for use of these analyzers in the field.

  5. Comprehensive laboratory and field testing of cavity ring-down spectroscopy analyzers measuring H2O, CO2, CH4 and CO

    NASA Astrophysics Data System (ADS)

    Yver Kwok, C.; Laurent, O.; Guemri, A.; Philippon, C.; Wastine, B.; Rella, C. W.; Vuillemin, C.; Truong, F.; Delmotte, M.; Kazan, V.; Darding, M.; Lebègue, B.; Kaiser, C.; Ramonet, M.

    2015-04-01

    To develop an accurate measurement network of greenhouse gases, instruments in the field need to be stable and precise and thus require infrequent calibrations and a low consumption of consumables. For about ten years, cavity ring-down spectroscopy (CRDS) analyzers have been available that meet these stringent requirements for precision and stability. Here, we present the results of tests of CRDS instruments in the laboratory (47 instruments) and in the field (15 instruments). The precision and stability of the measurements are studied. We demonstrate that, thanks to rigorous testing, newer models generally perform better than older models, especially in terms of reproducibility between instruments. In the field, we see the importance of individual diagnostics during the installation phase, and we show the value of calibration and target gases that assess the quality of the data. Finally, we formulate recommendations for use of these analyzers in the field.

  6. Chronic obstructive pulmonary disease, bronchial asthma and allergic rhinitis in the adult population within the commonwealth of independent states: rationale and design of the CORE study.

    PubMed

    Feshchenko, Yuriy; Iashyna, Liudmyla; Nugmanova, Damilya; Gyrina, Olga; Polianska, Maryna; Markov, Alexander; Moibenko, Maryna; Makarova, Janina; Tariq, Luqman; Pereira, Marcelo Horacio S; Mammadbayov, Eljan; Akhundova, Irada; Vasylyev, Averyan

    2017-10-10

    Main treatable Chronic Respiratory Diseases (CRDs) like Chronic Obstructive Pulmonary Disease (COPD), Bronchial Asthma (BA) and Allergic Rhinitis (AR) are underdiagnosed and undertreated worldwide. CORE study was aimed to assess the point prevalence of COPD, BA and AR in the adult population of major cities of Commonwealth of Independent States (CIS) countries - Azerbaijan, Kazakhstan, and Ukraine based on study questionnaires and/or spirometry, and to document risk factors, characterize the COPD, BA and AR population to provide a clearer "epidemiological data". A descriptive, cross-sectional, population-based epidemiological study conducted from 2013 to 2015 with two-stage cluster geographical randomization. Interviewers conducted face-to-face visits at respondent's household after informed consent and eligibility assessment including interviews, anthropometry, spirometry (with bronchodilator test) and completion of disease-specific questionnaires. Two thousand eight hundred forty-two respondents (Ukraine: 964 from Ukraine; 945 from Kazakhstan; 933 Azerbaijan) were enrolled. Mean age was 40-42 years and males were 37%-42% across three countries. In Kazakhstan 62.8% were Asians, but in Ukraine and in Azerbaijan 99.7% and 100.0%, respectively, were Caucasians. Manual labourers constituted 40.5% in Ukraine, 22.8% in Kazakhstan and 22.0% in Azerbaijan, while office workers were 16.1%, 31.6% and 36.8% respectively. 51.3% respondents in Ukraine, 64.9% in Kazakhstan and 69.7% in Azerbaijan were married. CORE study collected information that can be supportive for health policy decision makers in allocating healthcare resources in order to improve diagnosis and management of CRDs. The detailed findings will be described in future publications. Study Protocol Summary is disclosed at GlaxoSmithKline Clinical Study Register on Jun 06, 2013, study ID 116757 .

  7. Test/QA Plan for Verification of Cavity Ringdown Spectroscopy Systems for Ammonia Monitoring in Stack Gas

    EPA Science Inventory

    The purpose of the cavity ringdown spectroscopy (CRDS) technology test and quality assurance plan is to specify procedures for a verification test applicable to commercial cavity ringdown spectroscopy technologies. The purpose of the verification test is to evaluate the performa...

  8. High Resolution Infrared Spectra of Plasma Jet-Cooled - and Triacetylene in the C-H Stretch Region by CW Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhao, D.; Guss, J.; Walsh, A.; Doney, K.; Linnartz, H.

    2013-06-01

    Polyacetylenes form an important series of unsaturated hydrocarbons that are of astrophysical interest. Small polyacetylenes have been detected from infrared observations in dense atmosphere of Titan and in a protoplanetary nebula CRL 618. We present here high-resolution mid-infrared spectra of diacetylene (HC_{4}H) and triacetylene (HC_{6}H) that are recorded in a supersonically expanded pulsed planar plasma using an ultra-sensitive detection technique. This method uses an all fiber-laser-based optical parametric oscillator (OPO), in combination with continuous wave cavity ring-down spectroscopy (cw-CRDS) as a direct absorption detection tool. A hardware-based multi-trigger concept is developed to apply cw-CRDS to pulsed plasmas. Vibrationally hot but rotationally cold HC_{4}H and HC_{6}H are produced by discharging a C_{2}H_{2}/He/Ar gas mixture which is supersonically expanded into a vacuum chamber through a slit discharge nozzle. Experimental spectra are recorded at a resolution of ˜100 MHz in the 3305-3340 cm^{-1} region, which is characteristic of the C-H stretch vibrations of HC_{4}H and HC_{6}H. Jet-cooling in our experiment reduces the rotational temperature of both HC_{4}H and HC_{6}H to <20 K. In total, ˜2000 lines are measured. More than fourteen (vibrationally hot) bands for HC_{4}H and four bands for HC_{6}H are assigned based on Loomis-Wood diagrams, and nearly half of these bands are analyzed for the first time. For both molecules improved and new molecular constants of a series of vibrational levels are presented. The accurate molecular data reported here, particularly those for low-lying (bending) vibrational levels may be used to interpret the ro-vibrational transitions in the FIR and submillimeter/THz region. D. Zhao, J. Guss, A. Walsh, H. Linnartz Chem. Phys. Lett., {dx.doi.org/10.1016/j.cplett.2013.02.025}, in press, 2013.

  9. LWIR hyperspectral micro-imager for detection of trace explosive particles

    NASA Astrophysics Data System (ADS)

    Bingham, Adam L.; Lucey, Paul G.; Akagi, Jason T.; Hinrichs, John L.; Knobbe, Edward T.

    2014-05-01

    Chemical micro-imaging is a powerful tool for the detection and identification of analytes of interest against a cluttered background (i.e. trace explosive particles left behind in a fingerprint). While a variety of groups have demonstrated the efficacy of Raman instruments for these applications, point by point or line by line acquisition of a targeted field of view (FOV) is a time consuming process if it is to be accomplished with useful spatial resolutions. Spectrum Photonics has developed and demonstrated a prototype system utilizing long wave infrared hyperspectral microscopy, which enables the simultaneous collection of LWIR reflectance spectra from 8-14 μm in a 30 x 7 mm FOV with 30 μm spatial resolution in 30 s. An overview of the uncooled Sagnac-based LWIR HSM system will be given, emphasizing the benefits of this approach. Laboratory Hyperspectral data collected from custom mixtures and fingerprint residues is shown, focusing on the ability of the LWIR chemical micro-imager to detect chemicals of interest out of a cluttered background.

  10. A novel C-type lectin with triple carbohydrate recognition domains has critical roles for the hard tick Haemaphysalis longicornis against Gram-negative bacteria.

    PubMed

    Maeda, Hiroki; Miyata, Takeshi; Kusakisako, Kodai; Galay, Remil Linggatong; Talactac, Melbourne Rio; Umemiya-Shirafuji, Rika; Mochizuki, Masami; Fujisaki, Kozo; Tanaka, Tetsuya

    2016-04-01

    C-type lectins (CLecs) play an important role in innate immunity against invaders. In this study, a novel CLec was identified from Haemaphysalis longicornis ticks (HlCLec). HlCLec contains a signal peptide and a transmembrane region. Interestingly, HlCLec possesses three dissimilar carbohydrate recognition domains (CRDs). Each CRD contains the mutated motif of Ca(2+)-binding site 2. HlCLec mRNA was up-regulated during blood feeding, and had highest expression in the midgut and ovary. HlCLec localization was also confirmed by immunofluorescent antibody test (IFAT). HlCLec was found on the cell membrane and basal lamina of midgut and ovary. In addition, the recombinant HlCLec and individual CRDs demonstrated direct binding activity to Escherichia coli and Staphylococcus aureus; however, no growth inhibition activity was observed. Furthermore, E. coli injection after silencing of HlCLec caused drastic reduction in survival rate of ticks. These results strongly suggest the key role of HlCLec in tick innate immunity against Gram-negative bacteria. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. The CRDS method application for study of the gas-phase processes in the hot CVD diamond thin film.

    NASA Astrophysics Data System (ADS)

    Buzaianumakarov, Vladimir; Hidalgo, Arturo; Morell, Gerardo; Weiner, Brad; Buzaianu, Madalina

    2006-03-01

    For detailed analysis of problem related to the hot CVD carbon-containing nano-material growing, we have to detect different intermediate species forming during the growing process as well as investigate dependences of concentrations of these species on different experimental parameters (concentrations of the CJH4, H2S stable chemical compounds and distance from the filament system to the substrate surface). In the present study, the HS and CS radicals were detected using the Cavity Ring Down Spectroscopic (CRDS) method in the hot CVD diamond thin film for the CH4(0.4 %) + H2 mixture doped by H2S (400 ppm). The absolute absorption density spectra of the HS and CS radicals were obtained as a function of different experimental parameters. This study proofs that the HS and CS radicals are an intermediate, which forms during the hot filament CVD process. The kinetics approach was developed for detailed analysis of the experimental data obtained. The kinetics scheme includes homogenous and heterogenous processes as well as processes of the chemical species transport in the CVD chamber.

  12. The discrete Fourier transform algorithm for determining decay constants—Implementation using a field programmable gate array

    NASA Astrophysics Data System (ADS)

    Bostrom, G.; Atkinson, D.; Rice, A.

    2015-04-01

    Cavity ringdown spectroscopy (CRDS) uses the exponential decay constant of light exiting a high-finesse resonance cavity to determine analyte concentration, typically via absorption. We present a high-throughput data acquisition system that determines the decay constant in near real time using the discrete Fourier transform algorithm on a field programmable gate array (FPGA). A commercially available, high-speed, high-resolution, analog-to-digital converter evaluation board system is used as the platform for the system, after minor hardware and software modifications. The system outputs decay constants at maximum rate of 4.4 kHz using an 8192-point fast Fourier transform by processing the intensity decay signal between ringdown events. We present the details of the system, including the modifications required to adapt the evaluation board to accurately process the exponential waveform. We also demonstrate the performance of the system, both stand-alone and incorporated into our existing CRDS system. Details of FPGA, microcontroller, and circuitry modifications are provided in the Appendix and computer code is available upon request from the authors.

  13. A CRDS approach to gas phase equilibrium constants: the case of N 2O 4 ↔ 2NO 2 at 283 K

    NASA Astrophysics Data System (ADS)

    Tuchler, Matthew F.; Schmidt, Kierstin L.; Morgan, Mackenzie

    2005-01-01

    We report a general technique for determining the gas phase equilibrium constant, KP, of the A ↔ 2C system using cavity ringdown spectroscopy (CRDS). Working at a constant temperature, the absorption of one of the equilibrium species is measured at two different total pressures. KP is determined from the total pressures of the equilibrium mixture and the ratio of the absorptions. Theoretical limits on sensitivity of this technique are described as a function of experimental conditions. We present results from the reaction N 2O 4 ↔ 2NO 2 measured at T = 283 K. KP measured in this experiment, 21 (±5) Torr, is found to be lower than that recommended by the NASA Panel for Data Evaluation, 32 Torr. [S.P. Sander, A.R. Ravishankara, D.M. Golden, C.E. Kolb, M.J. Kurylo, R.E. Huie, V.L. Orkin, M.J. Molina, G.K. Moortgat, B.J. Finlayson-Pitts, Chemical Kinetics and Photochemical Data for Use in Atmospheric Studies. Evaluation No. 14; Jet Propulsion Laboratory, Pasadena, CA, 2003].

  14. Pulsed Discharge Nozzle Cavity Ring Down Spectroscopy of Cold PAH Ions

    NASA Technical Reports Server (NTRS)

    Biennier, Ludovic; Salama, Farid; Allamandola, Louis J.; Scherer, James J.; DeVincenzi, Donald (Technical Monitor)

    2002-01-01

    The gas-phase electronic absorption spectra of the naphthalene (C10H8(+)) and acenaphthene (C12H10(+)) cations have been measured in the visible range in a free 10 jet planar expansion in an attempt to collect data in an astrophysically relevant environment. The direct absorption spectra of two out of four bands measured of the gas-phase cold naphthalene cation along with the gas-phase vibronic absorption spectrum of the cold acenaphthene cation are reported for the first time. The study has been carried out using the ultrasensitive and versatile technique of cavity ringdown spectroscopy (CRDS) coupled to a pulsed discharge slit nozzle (PDN). The new CRDS-PDN set up is described and its characteristics are evaluated. The direct-absorption spectra of the PAH ions are discussed and compared to the gas-phase and solid-phase data available in the literature. The analysis of the results show that cold, free flying PAH ions are generated in the argon discharge primarily through soft Penning ionization. This enables the intrinsic band profiles to be measured, a key requirement for astrophysical applications.

  15. Portraying the Dead.

    ERIC Educational Resources Information Center

    Ruby, Jay

    1989-01-01

    Explores custom of post-mortem photography. Describes practice of post-mortem photography in 19th century America and traces changes in post-mortem photography in the 20th century. Discusses value of photographs in mourning process and suggests more thorough examination of the place of death-related photographs in grief management. (Author/NB)

  16. Quantification of Alkyl Nitrates in Ambient Air by Thermal Dissociation Cavity Ring-Down Spectroscopy with Preconcentration

    NASA Astrophysics Data System (ADS)

    Ye, C. Z.; Osthoff, H. D.; Taha, Y. M.; Pak, J. K.; Saowapon, M. T.

    2015-12-01

    Alkyl nitrates (AN, molecular formula RONO2) play a crucial role in the troposphere as temporary reservoirs of nitrogen oxides (NOx =NO +NO2) and by acting as chain terminators in the photochemical production of ozone. Mixing ratios of AN in ambient air are commonly quantified by gas chromatography with electron capture or mass spectrometric detection (GC-ECD or GC-MS) coupled to purge-and-trap preconcentration, usually on Tenax sorbent, to improve the detection limits. The analysis, however, is quite laborious as there are many alkyl nitrates that are low in individual abundance (often less than 1 parts-per-trillion by volume, pptv) and that exhibit different instrumental response factors. An alternative method is to determine alkyl nitrates as a sum (ΣAN) by thermal dissociation (TD) to a common fragment (NO2), which can then be quantified with a uniform response factor by optical absorption, for example by cavity ring-down spectroscopy (CRDS). However, the determination of ΣAN by TD-CRDS is hampered by its relatively high detection limits (several 100 pptv) and secondary chemistry following TD that results in both negative and positive interferences and depends on the composition of the ambient air sampled. In this work, a TD-CRDS equipped with a Tenax preconcentration unit is described. Matrix effects are minimized by desorbing the samples from the Tenax in a background of nitrogen. The performance of the instrument, in particular the recovery from the Tenax sorbent, was evaluated by sampling laboratory-generated mixtures of alkyl and peroxyacyl nitrates. Field data from a coastal site collected during the Ozone-depleting reactions in a coastal atmosphere (ORCA) campaign, which took place at the Amphitrite Point Observatory in Ucluelet, BC, from July 6 - 31, 2015, are presented. Advantages and disadvantages of the new method are discussed.

  17. Near Infrared Cavity Ring-Down Spectroscopy for Isotopic Analyses of CH4 on Future Martian Surface Missions

    NASA Technical Reports Server (NTRS)

    Chen, Y.; Mahaffy P.; Holmes, V.; Burris, J.; Morey, P.; Lehmann, K.K.; Lollar, B. Sherwood; Lacrampe-Couloume, G.; Onstott, T.C.

    2014-01-01

    A compact Near Infrared Continuous Wave Cavity Ring-Down Spectrometer (near-IR-cw-CRDS) was developed as a candidate for future planetary surface missions. The optical cavity was made of titanium with rugged quartz windows to protect the delicate super cavity from the harsh environmental changes that it would experience during space flight and a Martian surface mission. This design assured the long-term stability of the system. The system applied three distributed feedback laser diodes (DFB-LD), two of which were tuned to the absorption line peaks of (sup 12)CH4 and (sup 13)CH4 at 6046.954 inverse centimeters and 6049.121 inverse centimeters, respectively. The third laser was tuned to a spectral-lines-free region for measuring the baseline cavity loss. The multiple laser design compensated for typical baseline drift of a CRDS system and, thus, improved the overall precision. A semiconductor optical amplifier (SOA) was used instead of an Acousto-Optic Module (AOM) to initiate the cavity ring-down events. It maintained high acquisition rates such as AOM, but consumed less power. High data acquisition rates combined with improved long-term stability yielded precise isotopic measurements in this near-IR region even though the strongest CH4 absorption line in this region is 140 times weaker than that of the strongest mid-IR absorption band. The current system has a detection limit of 1.4 times 10( sup –12) inverse centimeters for (sup 13)CH4. This limit corresponds to approximately 7 parts per trillion volume of CH4 at 100 Torrs. With no further improvements the detection limit of our current near IR-cw-CRDS at an ambient Martian pressure of approximately 6 Torrs (8 millibars) would be 0.25 parts per billion volume for one 3.3 minute long analysis.

  18. Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

    NASA Astrophysics Data System (ADS)

    Rauner, D.; Kurutz, U.; Fantz, U.

    2015-04-01

    As the negative hydrogen ion density nH- is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H- is measured directly, however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H- is produced in the plasma volume, laser photodetachment is applied as the standard method to measure nH-. The additional application of CRDS provides the possibility to directly obtain absolute values of nH-, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H- production and destruction processes. The modelled densities are adapted to the absolute measurements of nH- via CRDS, allowing to identify collisions of H- with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H- in the plasma volume at HOMER. Furthermore, the characteristic peak of nH- observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as ne determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.

  19. An Empirical Spectroscopic Database for Acetylene in the Regions of 5850-9415 CM^{-1}

    NASA Astrophysics Data System (ADS)

    Campargue, Alain; Lyulin, Oleg

    2017-06-01

    Six studies have been recently devoted to a systematic analysis of the high-resolution near infrared absorption spectrum of acetylene recorded by Cavity Ring Down spectroscopy (CRDS) in Grenoble and by Fourier-transform spectroscopy (FTS) in Brussels and Hefei. On the basis of these works, in the present contribution, we construct an empirical database for acetylene in the 5850 - 9415 \\wn region excluding the 6341-7000 \\wn interval corresponding to the very strong νb{1}+ νb{3} manifold. The database gathers and extends information included in our CRDS and FTS studies. In particular, the intensities of about 1700 lines measured by CRDS in the 7244-7920 \\wn are reported for the first time together with those of several bands of ^{12}C^{13}CH_{2} present in natural isotopic abundance in the acetylene sample. The Herman-Wallis coefficients of most of the bands are derived from a fit of the measured intensity values. A recommended line list is provided with positions calculated using empirical spectroscopic parameters of the lower and upper energy vibrational levels and intensities calculated using the derived Herman-Wallis coefficients. This approach allows completing the experimental list by adding missing lines and improving poorly determined positions and intensities. As a result the constructed line list includes a total of 10973 lines belonging to 146 bands of ^{12}C_{2}H_{2} and 29 bands of ^{12}C^{13}CH_{2}. For comparison the HITRAN2012 database in the same region includes 869 lines of 14 bands, all belonging to ^{12}C_{2}H_{2}. Our weakest lines have an intensity on the order of 10^{-29} cm/molecule,about three orders of magnitude smaller than the HITRAN intensity cut off. Line profile parameters are added to the line list which is provided in HITRAN format. The comparison to the HITRAN2012 line list or to results obtained using the global effective operator approach is discussed in terms of completeness and accuracy.

  20. An inter-comparison of HO2 measured by Fluorescence Assay by Gas Expansion and Cavity Ringdown Spectroscopy in the Highly Instrumented Reactor for Atmospheric Chemistry.

    NASA Astrophysics Data System (ADS)

    Brennan, A.; Onel, L. C.; Gianella, M.; Ronnie, G.; Aguila, A. L.; Hancock, G.; Whalley, L.; Seakins, P. W.; Ritchie, G.; Heard, D. E.

    2017-12-01

    HO2 is an important species in the atmosphere, as it is involved in the HOx radical reaction cycle that is critical to the oxidation of atmospheric pollutants and the ultimate cleaning of the troposphere. One of the most widely utilised methods to measure HO2 is Fluorescence Assay by Gas Expansion (FAGE), which indirectly measures HO2 by sampling into a low pressure cell and titrating HO2 with NO to produce OH that is then detected by Laser Induced Fluorescence. This is an indirect and non-absolute detection technique that requires careful calibration to convert the measured signal into [HO2], which involves the photolysis of H2O at 185 nm to produce OH and HO2, and is subject to 30 % errors at 2σ level. The work presented here shows the validation of the FAGE technique and its calibration procedure through inter-comparison experiments between the non-absolute FAGE technique and Cavity Ringdown Spectroscopy (CRDS), an absolute absorption based method. The CRDS system was used to excite the first O-H overtone of the HO2 absorption band at 1506.43 nm, and features a cavity length of 1.2 m and a total path of 60 km. The experiments were performed inside the 2.25 m3 stainless steel Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC), using a synthetic air mixture at 150 and 1000 mbar of pressure and 298 K. HO2 was generated by photolysis of Cl2 at 365 nm in the presence of CH3OH and O2, and the [HO2] was monitored using both instruments. Additionally, monitoring the temporal decay of HO2 during its self-reaction provided an alternative calibration method for the FAGE instrument, and allowed the absorption cross section of HO2 at 1506.43 nm, σHO2, to be measured. FAGE calibration factors determined through the second order decays of HO2 at 1000 mbar agreed within 8 % of the H2O photolysis method, and determinations of σHO2 at 150 and 1000 mbar agree with previously reported data within 20 % and 12 % respectively. [HO2] correlation plots between the two instruments at 150 and 1000 mbar showed very good agreements of 0.863 ± 0.004 and 0.903 ± 0.002 respectively. This consistency between the indirect FAGE and direct CRDS measurements of HO2 validates the FAGE method, which is widely used for field measurements of HO2 in the troposphere.

  1. Dr. Liver: A preoperative planning system of liver graft volumetry for living donor liver transplantation.

    PubMed

    Yang, Xiaopeng; Yang, Jae Do; Yu, Hee Chul; Choi, Younggeun; Yang, Kwangho; Lee, Tae Beom; Hwang, Hong Pil; Ahn, Sungwoo; You, Heecheon

    2018-05-01

    Manual tracing of the right and left liver lobes from computed tomography (CT) images for graft volumetry in preoperative surgery planning of living donor liver transplantation (LDLT) is common at most medical centers. This study aims to develop an automatic system with advanced image processing algorithms and user-friendly interfaces for liver graft volumetry and evaluate its accuracy and efficiency in comparison with a manual tracing method. The proposed system provides a sequential procedure consisting of (1) liver segmentation, (2) blood vessel segmentation, and (3) virtual liver resection for liver graft volumetry. Automatic segmentation algorithms using histogram analysis, hybrid level-set methods, and a customized region growing method were developed. User-friendly interfaces such as sequential and hierarchical user menus, context-sensitive on-screen hotkey menus, and real-time sound and visual feedback were implemented. Blood vessels were excluded from the liver for accurate liver graft volumetry. A large sphere-based interactive method was developed for dividing the liver into left and right lobes with a customized cutting plane. The proposed system was evaluated using 50 CT datasets in terms of graft weight estimation accuracy and task completion time through comparison to the manual tracing method. The accuracy of liver graft weight estimation was assessed by absolute difference (AD) and percentage of AD (%AD) between preoperatively estimated graft weight and intraoperatively measured graft weight. Intra- and inter-observer agreements of liver graft weight estimation were assessed by intraclass correlation coefficients (ICCs) using ten cases randomly selected. The proposed system showed significantly higher accuracy and efficiency in liver graft weight estimation (AD = 21.0 ± 18.4 g; %AD = 3.1% ± 2.8%; percentage of %AD > 10% = none; task completion time = 7.3 ± 1.4 min) than the manual tracing method (AD = 70.5 ± 52.1 g; %AD = 10.2% ± 7.5%; percentage of %AD > 10% = 46%; task completion time = 37.9 ± 7.0 min). The proposed system showed slightly higher intra- and inter-observer agreements (ICC = 0.996 to 0.998) than the manual tracing method (ICC = 0.979 to 0.999). The proposed system was proved accurate and efficient in liver graft volumetry for preoperative planning of LDLT. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. CAD-based stand-alone spacecraft radiation exposure analysis system: An application of the early man-tended Space Station

    NASA Technical Reports Server (NTRS)

    Appleby, M. H.; Golightly, M. J.; Hardy, A. C.

    1993-01-01

    Major improvements have been completed in the approach to analyses and simulation of spacecraft radiation shielding and exposure. A computer-aided design (CAD)-based system has been developed for determining the amount of shielding provided by a spacecraft and simulating transmission of an incident radiation environment to any point within or external to the vehicle. Shielding analysis is performed using a customized ray-tracing subroutine contained within a standard engineering modeling software package. This improved shielding analysis technique has been used in several vehicle design programs such as a Mars transfer habitat, pressurized lunar rover, and the redesigned international Space Station. Results of analysis performed for the Space Station astronaut exposure assessment are provided to demonastrate the applicability and versatility of the system.

  3. Method and apparatus for elemental and isotope measurements and diagnostics-microwave induced plasma-cavity ring-down spectroscopy

    DOEpatents

    Wang, Chuji; Winstead, Christopher; Duan, Yixiang

    2006-05-30

    Provided is a novel system for conducting elemental measurements using cavity ring-down spectroscopy (CRDS). The present invention provides sensitivity thousands of times improved over conventional devices and does so with the advantages of low power, low plasma flow rate, and the ability being sustained with various gases.

  4. Exploring Faraday's Law of Electrolysis Using Zinc-Air Batteries with Current Regulative Diodes

    ERIC Educational Resources Information Center

    Kamata, Masahiro; Paku, Miei

    2007-01-01

    Current regulative diodes (CRDs) are applied to develop new educational experiments on Faraday's law by using a zinc-air battery (PR2330) and a resistor to discharge it. The results concluded that the combination of zinc-air batteries and the CRD array is simpler, less expensive, and quantitative and gives accurate data.

  5. The "Little" Cultural Tradition of Hispanics. (La "Pequena" Tradicion Cultural de los Hispanos.)

    ERIC Educational Resources Information Center

    Benitez, Jose Spielberg

    1980-01-01

    Defining "little" cultural traditions as those customs, behaviors and attitudes of ordinary people involved in the day-to-day problems of living and survival, this article traces the origins, historic influences and general characteristics of Hispanic culture and of its Mexican, Puerto Rican and Cuban subcultures. (DS)

  6. Cell Phone Roulette and "Consumer Interactive" Quality

    ERIC Educational Resources Information Center

    Navarro, Peter

    2005-01-01

    Under current policies, cell phone consumers face a lower probability of finding the best carrier for their usage patterns than winning at roulette. Corroborating survey data consistently show significant dissatisfaction among cell phone users, network performance is a major issue, and customer "churn" is high. This problem may be traced to a new…

  7. The self- and foreign-absorption continua of water vapor by cavity ring-down spectroscopy near 2.35 μm.

    PubMed

    Mondelain, D; Vasilchenko, S; Čermák, P; Kassi, S; Campargue, A

    2015-07-21

    The room temperature self- and foreign-continua of water vapor have been measured near 4250 cm(-1) with a newly developed high sensitivity cavity ring down spectrometer (CRDS). The typical sensitivity of the recordings is αmin≈ 6 × 10(-10) cm(-1) which is two orders of magnitude better than previous Fourier transform spectroscopy (FTS) measurements in the spectral region. The investigated spectral interval is located in the low energy range of the important 2.1 μm atmospheric transparency window. Self-continuum cross-sections, CS, were retrieved from the quadratic dependence of the spectrum base line level measured for different water vapor pressures between 0 and 15 Torr, after subtraction of the local water monomer lines contribution calculated using HITRAN2012 line parameters. The CS values were determined with 5% accuracy for four spectral points between 4249.2 and 4257.3 cm(-1). Their values of about 3.2 × 10(-23) cm(2) molecule(-1) atm(-1) are found 20% higher than predicted by the MT_CKD V2.5 model but two times weaker than reported in the literature using FTS. The foreign-continuum was evaluated by injecting various amounts of synthetic air in the CRDS cell while keeping the initial water vapor partial pressure constant. The foreign-continuum cross-section, CF, was retrieved from a linear fit of the spectrum base line level versus the air pressure. The obtained CF values are larger by a factor of 4.5 compared to the MT_CKD values and smaller by a factor of 1.7 compared to previous FTS values. As a result, for an atmosphere at room temperature with 60% relative humidity, the foreign-continuum contribution to the water continuum near 4250 cm(-1) is found to be on the same order as the self-continuum contribution.

  8. Do birds of like feather flock together? The use of a novel 13C+D combustion isotope analyzer to track bird migration

    NASA Astrophysics Data System (ADS)

    Saad, N.

    2011-12-01

    Information on spring migration routes, geographic linkages among winter, spring, and breeding locations, and potential geographic effects on arrival body condition of a variety of avian species is so far little known. Stable isotope ratios are exquisitely sensitive to the biochemistry of living organisms and the nutrients available to them. Isotope ratios provide detailed knowledge useful in a variety of fields, including birds migration, through a combination of stable-isotope measurements of carbon (13C/12C) and hydrogen (D/H) isotopes of flight feathers and breast feathers of tissues representing different periods of dietary integration and body composition analyses. Associations among specific geographic areas, habitat use, and arrival condition can be elucidated through the measurement of these dual isotopes. We report here on the development of a novel laser spectroscopy based system for the simultaneous analysis of the stable isotope ratios of carbon (13C/12C) and hydrogen (D/H) that is robust, easy-to-use, and is the first stable isotope ratio analysis system to combine the measurement of 13C/12C and D/H in one simple analysis from a bulk organic sample with an application to bird migration. The system comprises a combustion module to convert the organic sample into CO2 and H2O and a Cavity Ring-Down Spectrometer (CRDS) that analyzes the combustion species inside an optical cavity based on the molecular absorption of individual isotopomers. This CRDS uses dual lasers to target the four isotpomers of interest: 12CO2, 13CO2, H2O and HDO. The system delivers a typical precision of 0.1 permil for δ13C and 1.5 permil for δD that parallels that achieved by IRMS, but with an unprecedented simplicity that allows ecologists to leverage the science and elucidate the avian migration patterns.

  9. Compensation method for obtaining accurate, sub-micrometer displacement measurements of immersed specimens using electronic speckle interferometry.

    PubMed

    Fazio, Massimo A; Bruno, Luigi; Reynaud, Juan F; Poggialini, Andrea; Downs, J Crawford

    2012-03-01

    We proposed and validated a compensation method that accounts for the optical distortion inherent in measuring displacements on specimens immersed in aqueous solution. A spherically-shaped rubber specimen was mounted and pressurized on a custom apparatus, with the resulting surface displacements recorded using electronic speckle pattern interferometry (ESPI). Point-to-point light direction computation is achieved by a ray-tracing strategy coupled with customized B-spline-based analytical representation of the specimen shape. The compensation method reduced the mean magnitude of the displacement error induced by the optical distortion from 35% to 3%, and ESPI displacement measurement repeatability showed a mean variance of 16 nm at the 95% confidence level for immersed specimens. The ESPI interferometer and numerical data analysis procedure presented herein provide reliable, accurate, and repeatable measurement of sub-micrometer deformations obtained from pressurization tests of spherically-shaped specimens immersed in aqueous salt solution. This method can be used to quantify small deformations in biological tissue samples under load, while maintaining the hydration necessary to ensure accurate material property assessment.

  10. Evaluation of the Williams-type model for barley yields in North Dakota and Minnesota

    NASA Technical Reports Server (NTRS)

    Barnett, T. L. (Principal Investigator)

    1981-01-01

    The Williams-type yield model is based on multiple regression analysis of historial time series data at CRD level pooled to regional level (groups of similar CRDs). Basic variables considered in the analysis include USDA yield, monthly mean temperature, monthly precipitation, soil texture and topographic information, and variables derived from these. Technologic trend is represented by piecewise linear and/or quadratic functions of year. Indicators of yield reliability obtained from a ten-year bootstrap test (1970-1979) demonstrate that biases are small and performance based on root mean square appears to be acceptable for the intended AgRISTARS large area applications. The model is objective, adequate, timely, simple, and not costly. It consideres scientific knowledge on a broad scale but not in detail, and does not provide a good current measure of modeled yield reliability.

  11. VizieR Online Data Catalog: Gas-phase detection of c-C3H3

    NASA Astrophysics Data System (ADS)

    Zhao, D.; Doney, K. D.; Linnartz, H.

    2017-03-01

    The experimental setup has been described in detail by Zhao et al. (2013CPL...565..132Z, 2014JMoSp.296....1Z). In brief, the c-C3H3+ cations are generated by discharging a propyne (C3H4):He ~ 1:200 gas mixture in a multi-layer slit discharge nozzle (Motylewski & Linnartz 1999RScI...70.1305M) in combination with a pulsed valve (General Valve, Series 9,2 mm orifice). The gas mixture is expanded with a backing pressure of ~7 bar through a 300umx3cm slit into a vacuum chamber. A pulsed negative high voltage (-600 V/300 mA) with a ~600 us duration is found to be optimum for c-C3H3+ production, is applied to the expanding gas mixture, and is set to coincide with the expanding gas pulse (~800 us). Continuous-wave cavity ring-down spectroscopy (cw-CRDS) is used to record spectra in direct absorption. The axis of the optical cavity is aligned parallel to and ~2 mm downstream of the slit nozzle throat. A single-mode cw optical parametric oscillator (Aculight), operating at ~3.15 um with a bandwidth <5x10-5cm-1, is employed as tunable IR light source. A hardware-based (boxcar integrator) multi-trigger and timing scheme recently reported by Zhao et al. (2013CPL...565..132Z) is used to apply cw-CRDS to the pulsed plasma. In the present experiment, typical ring-down time values are ~8-10 us, corresponding to a detection sensitivity, i.e., noise equivalent absorption, of up to ~2x10-7 per centimeter for the 3 cm long plasma jet. (1 data file).

  12. Spectroscopic detection, characterization and dynamics of free radicals relevant to combustion processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Terry

    2015-06-04

    Combustion chemistry is enormously complex. The chemical mechanisms involve a multitude of elementary reaction steps and a comparable number of reactive intermediates, many of which are free radicals. Computer simulations based upon these mechanisms are limited by the validity of the mechanisms and the parameters characterizing the properties of the intermediates and their reactivity. Spectroscopy can provide data for sensitive and selective diagnostics to follow their reactions. Spectroscopic analysis also provides detailed parameters characterizing the properties of these intermediates. These parameters serve as experimental gold standards to benchmark predictions of these properties from large-scale, electronic structure calculations. This work hasmore » demonstrated the unique capabilities of near-infrared cavity ringdown spectroscopy (NIR CRDS) to identify, characterize and monitor intermediates of key importance in complex chemical reactions. Our studies have focussed on the large family of organic peroxy radicals which are arguably themost important intermediates in combustion chemistry and many other reactions involving the oxidation of organic compounds. Our spectroscopic studies have shown that the NIR Ã - ˜X electronic spectra of the peroxy radicals allows one to differentiate among chemical species in the organic peroxy family and also determine their isomeric and conformic structure in many cases. We have clearly demonstrated this capability on saturated and unsaturated peroxy radicals and β-hydroxy peroxy radicals. In addition we have developed a unique dual wavelength CRDS apparatus specifically for the purpose of measuring absolute absorption cross section and following the reaction of chemical intermediates. The utility of the apparatus has been demonstrated by measuring the cross-section and self-reaction rate constant for ethyl peroxy.« less

  13. SERS-based pesticide detection by using nanofinger sensors

    NASA Astrophysics Data System (ADS)

    Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong

    2015-01-01

    Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.

  14. Preventing Active Timing Attacks in Low-Latency Anonymous Communication

    DTIC Science & Technology

    2010-04-26

    measured routers with the modifiers “Exit”, “Fast”, “Running”, “Stable”, and “Valid”. The routers also had to be non- hibernating and could not have exit...Tor client was a custom client written in Java . Packet traces were recorded using tcpdump. The timestamps on these were used to determine the timing of

  15. 19 CFR 191.26 - Recordkeeping for manufacturing drawback.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... producer under 19 U.S.C. 1313(a) shall keep records to allow the verifying Customs official to trace all... or producer of articles manufactured or produced in accordance with 19 U.S.C. 1313(b) shall establish... drawback claim under 19 U.S.C. 1313(b). The amount of titanium dioxide in the synthetic rutile is...

  16. 19 CFR 191.26 - Recordkeeping for manufacturing drawback.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... producer under 19 U.S.C. 1313(a) shall keep records to allow the verifying Customs official to trace all... or producer of articles manufactured or produced in accordance with 19 U.S.C. 1313(b) shall establish... drawback claim under 19 U.S.C. 1313(b). The amount of titanium dioxide in the synthetic rutile is...

  17. 19 CFR 191.26 - Recordkeeping for manufacturing drawback.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... producer under 19 U.S.C. 1313(a) shall keep records to allow the verifying Customs official to trace all... or producer of articles manufactured or produced in accordance with 19 U.S.C. 1313(b) shall establish... drawback claim under 19 U.S.C. 1313(b). The amount of titanium dioxide in the synthetic rutile is...

  18. Traces of illegal drugs on body surfaces: indicator for consumption or dealing?

    NASA Astrophysics Data System (ADS)

    Aberl, Franz; Bonenberger, Johannes; Berg, Ralf-Peter; Zimmermann, Rudolph; Sachs, Hans W.

    1997-01-01

    Customs investigation and drug enforcement services are interest in a rapid and reliable identification of smugglers and dealers. In contrast workplace testing and traffic controls are aiming at the detection of intoxicated persons via the determination of illegal narcotics in body fluids like urine or blood. DRUGWIPE is a pen size, test strip based immunochemical detector for narcotic contaminations on surfaces. It is extremely simple to apply and takes about two minutes to read test results without depending upon any further technical means. This paper describes the applicability of DRUGWIPE to identify drug smugglers or dealers as well as consumers. With respect to the situation and the initial suspicion the test indicates handling as well as consumption. In cooperation with the Institute for Legal Medicine in Munich suspicious drivers were examined with DRUGWIPE for the abuse of illegal narcotics. Test results from this test series are presented and compared with the results from the blood or urine analysis. The question whether the detected traces of illegal narcotics on the body surface of suspicious drivers are combing transpiration or external contamination are discussed.

  19. Integrating Cache Performance Modeling and Tuning Support in Parallelization Tools

    NASA Technical Reports Server (NTRS)

    Waheed, Abdul; Yan, Jerry; Saini, Subhash (Technical Monitor)

    1998-01-01

    With the resurgence of distributed shared memory (DSM) systems based on cache-coherent Non Uniform Memory Access (ccNUMA) architectures and increasing disparity between memory and processors speeds, data locality overheads are becoming the greatest bottlenecks in the way of realizing potential high performance of these systems. While parallelization tools and compilers facilitate the users in porting their sequential applications to a DSM system, a lot of time and effort is needed to tune the memory performance of these applications to achieve reasonable speedup. In this paper, we show that integrating cache performance modeling and tuning support within a parallelization environment can alleviate this problem. The Cache Performance Modeling and Prediction Tool (CPMP), employs trace-driven simulation techniques without the overhead of generating and managing detailed address traces. CPMP predicts the cache performance impact of source code level "what-if" modifications in a program to assist a user in the tuning process. CPMP is built on top of a customized version of the Computer Aided Parallelization Tools (CAPTools) environment. Finally, we demonstrate how CPMP can be applied to tune a real Computational Fluid Dynamics (CFD) application.

  20. Broad spectrum infrared thermal desorption of wipe-based explosive and narcotic samples for trace mass spectrometric detection.

    PubMed

    Forbes, Thomas P; Staymates, Matthew; Sisco, Edward

    2017-08-07

    Wipe collected analytes were thermally desorbed using broad spectrum near infrared heating for mass spectrometric detection. Employing a twin tube filament-based infrared emitter, rapid and efficiently powered thermal desorption and detection of nanogram levels of explosives and narcotics was demonstrated. The infrared thermal desorption (IRTD) platform developed here used multi-mode heating (direct radiation and secondary conduction from substrate and subsequent convection from air) and a temperature ramp to efficiently desorb analytes with vapor pressures across eight orders of magnitude. The wipe substrate experienced heating rates up to (85 ± 2) °C s -1 with a time constant of (3.9 ± 0.2) s for 100% power emission. The detection of trace analytes was also demonstrated from complex mixtures, including plastic-bonded explosives and exogenous narcotics, explosives, and metabolites from collected artificial latent fingerprints. Manipulation of the emission power and duration directly controlled the heating rate and maximum temperature, enabling differential thermal desorption and a level of upstream separation for enhanced specificity. Transitioning from 100% power and 5 s emission duration to 25% power and 30 s emission enabled an order of magnitude increase in the temporal separation (single seconds to tens of seconds) of the desorption of volatile and semi-volatile species within a collected fingerprint. This mode of operation reduced local gas-phase concentrations, reducing matrix effects experienced with high concentration mixtures. IRTD provides a unique platform for the desorption of trace analytes from wipe collections, an area of importance to the security sector, transportation agencies, and customs and border protection.

  1. Ring resonant cavities for spectroscopy

    DOEpatents

    Zare, R.N.; Martin, J.; Paldus, B.A.; Xie, J.

    1999-06-15

    Ring-shaped resonant cavities for spectroscopy allow a reduction in optical feedback to the light source, and provide information on the interaction of both s- and p-polarized light with samples. A laser light source is locked to a single cavity mode. An intracavity acousto-optic modulator may be used to couple light into the cavity. The cavity geometry is particularly useful for Cavity Ring-Down Spectroscopy (CRDS). 6 figs.

  2. Ring resonant cavities for spectroscopy

    DOEpatents

    Zare, Richard N.; Martin, Juergen; Paldus, Barbara A.; Xie, Jinchun

    1999-01-01

    Ring-shaped resonant cavities for spectroscopy allow a reduction in optical feedback to the light source, and provide information on the interaction of both s- and p-polarized light with samples. A laser light source is locked to a single cavity mode. An intracavity acousto-optic modulator may be used to couple light into the cavity. The cavity geometry is particularly useful for Cavity Ring-Down Spectroscopy (CRDS).

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biraud, S. C.; Reichl, K.

    The Greenhouse Gas (GhG) Measurement system is a combination of two systems in series: (1) the Tower Gas Processing (TGP) System, an instrument rack which pulls, pressurizes, and dries air streams from an atmospheric sampling tower through a series of control and monitoring components, and (2) the Picarro model G2301 cavity ringdown spectrometer (CRDS), which measures CO2, CH4, and H2O vapor; the primary measurements of the GhG system.

  4. Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rauner, D.; Kurutz, U.; Fantz, U.

    2015-04-08

    As the negative hydrogen ion density n{sub H{sup −}} is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H{sup −} is measured directly,more » however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H{sup −} is produced in the plasma volume, laser photodetachment is applied as the standard method to measure n{sub H{sup −}}. The additional application of CRDS provides the possibility to directly obtain absolute values of n{sub H{sup −}}, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H{sup −} production and destruction processes. The modelled densities are adapted to the absolute measurements of n{sub H{sup −}} via CRDS, allowing to identify collisions of H{sup −} with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H{sup −} in the plasma volume at HOMER. Furthermore, the characteristic peak of n{sub H{sup −}} observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as n{sub e} determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.« less

  5. New on-line method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    NASA Astrophysics Data System (ADS)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-01-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us to simultaneously measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the on-line water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δD reliability. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water resulting in an artificial water background with well-known δD and δ18O values. The speleothem sample is placed into a copper tube, attached to the line and after system stabilisation is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain δD and δ18O isotopic composition of measured water aliquots. Precision is better than 1.5‰ for δD and 0.4‰ for δ18O for water measurement for an extended range (-210 to 0‰ for δD and -27 to 0‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to Isotope Ratio Mass Spectrometry (IRMS) technique.

  6. New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    NASA Astrophysics Data System (ADS)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-07-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (-210 to 0 ‰ for δ D and -27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.

  7. An empirical spectroscopic database for acetylene in the regions of 5850-6341 cm-1 and 7000-9415 cm-1

    NASA Astrophysics Data System (ADS)

    Lyulin, O. M.; Campargue, A.

    2017-12-01

    Six studies have been recently devoted to a systematic analysis of the high-resolution near infrared absorption spectrum of acetylene recorded by Cavity Ring Down spectroscopy (CRDS) in Grenoble and by Fourier-transform spectroscopy (FTS) in Brussels and Hefei. On the basis of these works, in the present contribution, we construct an empirical database for acetylene in the 5850-9415 cm-1 region excluding the 6341-7000 cm-1 interval corresponding to the very strong ν1+ν3 manifold. Our database gathers and extends information included in our CRDS and FTS studies. In particular, the intensities of about 1700 lines measured by CRDS in the 7244-7920 cm-1 region are reported for the first time together with those of several bands of 12C13CH2 present in natural isotopic abundance in the acetylene sample. The Herman-Wallis coefficients of most of the bands are derived from a fit of the measured intensity values. A recommended line list is provided with positions calculated using empirical spectroscopic parameters of the lower and upper energy vibrational levels and intensities calculated using the derived Herman-Wallis coefficients. This approach allows completing the experimental list by adding missing lines and improving poorly determined positions and intensities. As a result the constructed line list includes a total of 11113 transitions belonging to 150 bands of 12C2H2 and 29 bands of 12C13CH2. For comparison the HITRAN database in the same region includes 869 transitions of 14 bands, all belonging to 12C2H2. Our weakest lines have an intensity on the order of 10-29 cm/molecule, about three orders of magnitude smaller than the HITRAN intensity cut off. Line profile parameters are added to the line list which is provided in HITRAN format. The comparison of the acetylene database to the HITRAN2012 line list or to results obtained using the global effective operator approach is discussed in terms of completeness and accuracy.

  8. Eddy covariance flux measurements of gaseous elemental mercury using cavity ring-down spectroscopy.

    PubMed

    Pierce, Ashley M; Moore, Christopher W; Wohlfahrt, Georg; Hörtnagl, Lukas; Kljun, Natascha; Obrist, Daniel

    2015-02-03

    A newly developed pulsed cavity ring-down spectroscopy (CRDS) system for measuring atmospheric gaseous elemental mercury (GEM) concentrations at high temporal resolution (25 Hz) was used to successfully conduct the first eddy covariance (EC) flux measurements of GEM. GEM is the main gaseous atmospheric form, and quantification of bidirectional exchange between the Earth's surface and the atmosphere is important because gas exchange is important on a global scale. For example, surface GEM emissions from natural sources, legacy emissions, and re-emission of previously deposited anthropogenic pollution may exceed direct primary anthropogenic emissions. Using the EC technique for flux measurements requires subsecond measurements, which so far has not been feasible because of the slow time response of available instrumentation. The CRDS system measured GEM fluxes, which were compared to fluxes measured with the modified Bowen ratio (MBR) and a dynamic flux chamber (DFC). Measurements took place near Reno, NV, in September and October 2012 encompassing natural, low-mercury (Hg) background soils and Hg-enriched soils. During nine days of measurements with deployment of Hg-enriched soil in boxes within 60 m upwind of the EC tower, the covariance of GEM concentration and vertical wind speed was measured, showing that EC fluxes over an Hg-enriched area were detectable. During three separate days of flux measurements over background soils (without Hg-enriched soils), no covariance was detected, indicating fluxes below the detection limit. When fluxes were measurable, they strongly correlated with wind direction; the highest fluxes occurred when winds originated from the Hg-enriched area. Comparisons among the three methods showed good agreement in direction (e.g., emission or deposition) and magnitude, especially when measured fluxes originated within the Hg-enriched soil area. EC fluxes averaged 849 ng m(-2) h(-1), compared to DFC fluxes of 1105 ng m(-2) h(-1) and MBR fluxes of 1309 ng m(-2) h(-1). This study demonstrated that a CRDS system can be used to measure GEM fluxes over Hg-enriched areas, with a conservative detection limit estimate of 32 ng m(-2) h(-1).

  9. Detecting Hydrogen Chloride (HCl) in the Polluted Marine Boundary Layer Using Cavity Ring-Down Spectroscopy (CRDS)

    NASA Astrophysics Data System (ADS)

    Furlani, T.; Dawe, K.; VandenBoer, T. C.; Young, C.

    2017-12-01

    Oxidation initiated with chlorine atoms yields more ozone than oxidation initiated with hydroxyl radicals. Reasons for this are not fully understood, but the implications for mechanisms of oxidation chemistry are significant.1,2 Chlorine atoms have not been directly measured to date in the atmosphere and its abundance is usually inferred through steady-state approximations from all known formation and loss processes. A major reservoir for chlorine in the troposphere is by proton abstraction of organic compounds to form HCl.3 HCl can also be formed heterogeneously via acid displacement reactions with ubiquitously-found sodium chloride (NaCl) on solid surfaces with nitric acid (HNO3). The majority of the available chloride in the marine boundary layer comes from the sea salt in and around marine derived sea-spray aerosols. HCl is not a perfect sink and can react with hydroxyl radicals or be photolyzed to form chlorine atoms. The balance between loss and formation processes of chlorine atoms from HCl is highly dependent on many external factors, such as the wet and dry deposition rate of HCl. Measuring HCl in the gas and aerosol phase is important to the understanding of chlorine chemistry in the polluted marine boundary layer. HCl levels in the polluted marine boundary layer are typically between 100pptv-1ppbv,3 requiring the sensitive and selective detection capabilities of cavity ring-down spectroscopy (CRDS).4 We measured HCl using a Picarro CRDS in the polluted marine boundary layer for the first time. Measurements were conducted during April and May of 2017 in St. John's, Newfoundland and Labrador. The performance of the instrument will be discussed, as well as observations of HCl in the context of local conditions. References1Osthoff, H. D. et al. Nat. Geosci 1, 324-328 (2008). 2Young, C. J. et al. Atmos. Chem. Phys. 14, 3427-3440 (2014). 3Crisp, T. a et al. J. Geophys. Res. Atmos. 6897-6915 (2014). 4Hagen, C. L. et al. Atmos. Meas. Tech. 7, 345-357 (2014).

  10. Sub-ppb, Autonomous, Real-time Detection of VOCs with iCRDS

    NASA Astrophysics Data System (ADS)

    Leen, J.; Gupta, M.; Baer, D. S.

    2013-12-01

    The continuous, real-time detection of sub-parts-per-billion (ppb) concentrations of volatile organic compounds (VOCs) such as trichloroethylene (TCE) and tetrachloroethylene (PCE) remains difficult, time consuming and expensive. In particular, short term exposure spikes and diurnal variations are difficult or impossible to detect with traditional TO-15 measurements. We present laboratory and field performance data from an instrument based on incoherent cavity ringdown spectroscopy (iCRDS) that operates in the mid-infrared (bands from 860-1060 cm-1 or 970-1280 cm-1) and is capable of detecting a broad range of VOCs, in situ, continuously and autonomously. We have demonstrated the measurement of TCE in zero air with a precision of 0.17 ppb (1σ in 4 minutes). PCE was measured with a precision of 0.15 ppb (1σ in 4 minutes). Both of these measured precisions exceed the EPA's commercial building action limit, which for TCE is 0.92 ppb (5 μg/m3) and for PCE is 0.29 ppb (2 μg/m3). Additionally, the instrument is capable of precisely measuring and quantifying BTEX compounds (benzene, toluene, ethylbenzene, xylene), including differentiation of xylene isomers. We have demonstrated the accurate, interference free measurement of Mountain View, California air doped with TCE concentrations ranging from 4.22 ppb (22.8 μg/m3) to 17.74 ppb (96 μg/m3) with a precision of 1.42 ppb (1σ in 4 minutes). Mountain View, California air doped with 10.83 ppb of PCE (74.0 μg/m3) was measured with a precision of 0.54 ppb (1σ in 4 minutes). Finally, the instrument was deployed to the Superfund site at Moffett Naval Air Station in Mountain View, California where contaminated ground water results in vapor intrusion of TCE and PCE. For two weeks, the instrument operated continuously and autonomously, successfully measuring TCE and PCE concentrations in both the breathing zone and steam tunnel air. TCE concentrations in the breathing zone averaged 0.186 × 0.669 ppb while tunnel air averaged 17.38 × 4.96 ppb, in excellent agreement with previous TO-15 8 hr averages. PCE concentrations in the breathing zone averaged 0.063 × 0.270 ppb while tunnel air averaged 0.755 × 0.359 ppb, again, in excellent agreement with previous TO-15 8 hr averages. The iCRDS instrument has shown the ability to continuously and autonomously measure sub-ppb levels of toxic VOCs in the field, offering an unprecedented picture of the short term dynamics associated with vapor intrusion and ground water pollution.

  11. Cavity mode-width spectroscopy with widely tunable ultra narrow laser.

    PubMed

    Cygan, Agata; Lisak, Daniel; Morzyński, Piotr; Bober, Marcin; Zawada, Michał; Pazderski, Eugeniusz; Ciuryło, Roman

    2013-12-02

    We explore a cavity-enhanced spectroscopic technique based on determination of the absorbtion coefficient from direct measurement of spectral width of the mode of the optical cavity filled with absorbing medium. This technique called here the cavity mode-width spectroscopy (CMWS) is complementary to the cavity ring-down spectroscopy (CRDS). While both these techniques use information on interaction time of the light with the cavity to determine absorption coefficient, the CMWS does not require to measure very fast signals at high absorption conditions. Instead the CMWS method require a very narrow line width laser with precise frequency control. As an example a spectral line shape of P7 Q6 O₂ line from the B-band was measured with use of an ultra narrow laser system based on two phase-locked external cavity diode lasers (ECDL) having tunability of ± 20 GHz at wavelength range of 687 to 693 nm.

  12. Fiber cavity ring-down using an optical time-domain reflectometer

    NASA Astrophysics Data System (ADS)

    Passos, D. J.; Silva, S. O.; Fernandes, J. R. A.; Marques, M. B.; Frazão, O.

    2014-12-01

    This work presented a demonstration of the potential for a fiber based cavity ring-down (CRD) using an optical time-domain reflectometer (OTDR). The OTDR was used to send the impulses down into about 20 km of a standard single optical fiber, at the end of which the fiber cavity ring-down was placed. The OTDR measured no appreciable losses, so other CRDs multiplexed could be spliced in parallel along the same optical fiber. To demonstrate the behavior and sensitivity of the proposed configuration, a displacement sensor based on a fiber taper with a diameter of 50 μm was placed inside the fiber loop, and the induced losses were measured on the CRD signal — a sensitivity of 11.8 ± 0.5 μs/mm was achieved. The dynamic range of the sensing head used in this configuration was about 2 mm. Finally, this work was also compared with different works published in the literature.

  13. Explaining Verification Conditions

    NASA Technical Reports Server (NTRS)

    Deney, Ewen; Fischer, Bernd

    2006-01-01

    The Hoare approach to program verification relies on the construction and discharge of verification conditions (VCs) but offers no support to trace, analyze, and understand the VCs themselves. We describe a systematic extension of the Hoare rules by labels so that the calculus itself can be used to build up explanations of the VCs. The labels are maintained through the different processing steps and rendered as natural language explanations. The explanations can easily be customized and can capture different aspects of the VCs; here, we focus on their structure and purpose. The approach is fully declarative and the generated explanations are based only on an analysis of the labels rather than directly on the logical meaning of the underlying VCs or their proofs. Keywords: program verification, Hoare calculus, traceability.

  14. Low-Power Architecture for an Optical Life Gas Analyzer

    NASA Technical Reports Server (NTRS)

    Pilgrim, Jeffrey; Vakhtin, Andrei

    2012-01-01

    Analog and digital electronic control architecture has been combined with an operating methodology for an optical trace gas sensor platform that allows very low power consumption while providing four independent gas measurements in essentially real time, as well as a user interface and digital data storage and output. The implemented design eliminates the cross-talk between the measurement channels while maximizing the sensitivity, selectivity, and dynamic range for each measured gas. The combination provides for battery operation on a simple camcorder battery for as long as eight hours. The custom, compact, rugged, self-contained design specifically targets applications of optical major constituent and trace gas detection for multiple gases using multiple lasers and photodetectors in an integrated package.

  15. A measurement system for continuous observations of CO2, CH4, H2O and CO onboard passenger aircraft

    NASA Astrophysics Data System (ADS)

    Gerbig, Christoph; Filges, Annette; Franke, Harald; Klaus, Christoph; Chen, Huilin

    2013-04-01

    Improved quantification and understanding of surface-atmosphere exchange fluxes of greenhouse gases (GHGs) caused by natural as well as anthropogenic processes is of paramount importance in a world of a changing climate and ever increasing emissions. Top-down estimation of GHG fluxes is traditionally done by inverse transport modeling, using GHG observations from a global network of stations. Uncertainties in modeled vertical transport rates (moist convection, turbulent mixing, stratosphere-troposphere exchange) however greatly affect the quality of flux estimates. More recently, remote sensing of vertical column mole fractions of GHGs have become available for inverse modeling, reducing the impact of vertical transport uncertainties to first order. However, those need validation against in-situ observations. A strategy for regular, global in-situ atmospheric profiling of GHGs, covering at least the troposphere, is thus needed to provide validation of remote sensing and of forward transport modeling of GHGs, to serve as input for inverse modeling, and to reduce the impact of transport uncertainties. IAGOS-ERI (In-service Aircraft for a Global Observing System - European Research Infrastructure) exploits the synergy between globally operating civil aviation and the need for long-term monitoring of atmospheric composition. Within the framework of IAGOS-ERI a cavity ring-down spectroscopy (CRDS) based measurement system for greenhouse gases was designed, tested, and qualified for deployment on commercial airliners. The design meets requirements regarding physical dimensions (size, weight), performance (long-term stability, low maintenance, robustness, full automation) and safety issues (fire prevention regulations, airworthiness). The system uses components of a commercially available CRDS instrument (G2401-m, Picarro Inc.) mounted into a frame suitable for integration in the avionics bay of the Airbus A-340. The first of the IAGOS GHG packages is scheduled for integration in mid 2013. The aim is to have seven systems operational within four years, providing for long-term GHG observations with near-global coverage. To enable robust and automated operation of the IAGOS GHG package over six-month deployment periods, numerous technical issues had to be addressed. An inlet system, designed as virtual impactor to eliminate sampling of larger aerosols, ice particles, and water droplets, provides additional positive ram-pressure to ensure operation without an upstream sampling pump. Furthermore, no sample drying is required, as the simultaneously measured water vapor mole fraction is used to correct for dilution and spectroscopic effects. This also enables the collection of science-quality water vapor measurements throughout the atmosphere. To allow for trace gas measurements to be fully traceable to WMO scales, a two-standard calibration system has been designed and tested that periodically provides calibration gas to the instrument during flight and on ground for each six-month deployment period. We present results from recent test flights and laboratory tests that document the performance for GHG and water vapor measurements. Furthermore, future applications of the IAGOS-GHG data stream, provided in near-real-time via SatCom to the weather prediction centres, will be discussed.

  16. Unmanned aerial system laser based measurements of ammonia and methane emissions from animal feeding operations

    NASA Astrophysics Data System (ADS)

    Shadman, S.; McHale, L.; Miller, T.; Yalin, A.

    2017-12-01

    In the US, 40 Tg of ammonia is emitted every year into the atmosphere via agricultural activities. Ammonia is the third most abundant nitrogen containing species in the atmosphere and it has important impacts on atmospheric chemistry, health, and the environment. Since the atmospheric lifetime of ammonia is a few days, it typically deposits to the ground close to its source. In this study we are developing two laser-based sensors to measure ammonia and methane emissions from concentrated animal feeding operations (CAFOs) with the specific goal of quantifying the dry deposition of ammonia in the first few kilometers downwind of the CAFOs. Since methane is nonreactive and does not undergo dry deposition, its change in concentration with downwind distance is due to dispersion alone. We therefore plan to use methane as a conservative tracer, and will infer the ammonia deposition from the changing (deceasing) ratio of ammonia to methane as a function of downwind position. The laser sensors (ammonia and methane) developed in this study are relatively lightweight (<3.5 kg), low power (<40 W) and achieve part-per-billion level concentration sensitivity via sensitive open-path absorption spectroscopy methods. The sensors are designed for simultaneous airborne measurements of both species on a 12 foot Telemaster unmanned aerial system (UAS). The methane sensor employs cavity ring-down spectroscopy (CRDS) at 1.65 um with a distributed feedback laser and has effective cavity length of 20 km. The ammonia sensor employs wavelength modulation spectroscopy (WMS) with a quantum cascade laser at 10.33 um with a Herriot multipass cell (19 m effective length). In order to minimize the thermal expansion effects, most mounts and physical structures are made from carbon-fiber. For each sensor, a custom electronics module has been designed to control and power the electro-optic components, as well as to acquire, analyze, and save data (including concentration, temperature, pressure, and GPS time and position). The sensors have been characterized in the lab (Allan variance) and show sensitivities of 1.5 ppb (at 1 Hz) and 20 ppb (at 1 Hz), for ammonia and methane respectively.

  17. Frequency-agile, rapid scanning cavity ring-down spectroscopy (FARS-CRDS) measurements of the (30012)←(00001) near-infrared carbon dioxide band

    NASA Astrophysics Data System (ADS)

    Long, D. A.; Wójtewicz, S.; Miller, C. E.; Hodges, J. T.

    2015-08-01

    We present new high accuracy measurements of the (30012)←(00001) CO2 band near 1575 nm recorded with a frequency-agile, rapid scanning cavity ring-down spectrometer. The resulting spectra were fit with the partially correlated, quadratic-speed-dependent Nelkin-Ghatak profile with line mixing. Significant differences were observed between the fitted line shape parameters and those found in existing databases, which are based upon more simplistic line profiles. Absolute transition frequencies, which were referenced to an optical frequency comb, are given, as well as the other line shape parameters needed to model this line profile. These high accuracy measurements should allow for improved atmospheric retrievals of greenhouse gas concentrations by current and future remote sensing missions.

  18. Evanescent wave cavity ring-down spectroscopy (EW-CRDS) as a probe of macromolecule adsorption kinetics at functionalized interfaces.

    PubMed

    O'Connell, Michael A; de Cuendias, Anne; Gayet, Florence; Shirley, Ian M; Mackenzie, Stuart R; Haddleton, David M; Unwin, Patrick R

    2012-05-01

    Evanescent wave cavity ring-down spectroscopy (EW-CRDS) has been employed to study the interfacial adsorption kinetics of coumarin-tagged macromolecules onto a range of functionalized planar surfaces. Such studies are valuable in designing polymers for complex systems where the degree of interaction between the polymer and surface needs to be tailored. Three tagged synthetic polymers with different functionalities are examined: poly(acrylic acid) (PAA), poly(3-sulfopropyl methacrylate, potassium salt) (PSPMA), and a mannose-modified glycopolymer. Adsorption transients at the silica/water interface are found to be characteristic for each polymer, and kinetics are deduced from the initial rates. The chemistry of the adsorption interfaces has been varied by, first, manipulation of silica surface chemistry via the bulk pH, followed by surfaces modified by poly(L-glutamic acid) (PGA) and cellulose, giving five chemically different surfaces. Complementary atomic force microscopy (AFM) imaging has been used for additional surface characterization of adsorbed layers and functionalized interfaces to allow adsorption rates to be interpreted more fully. Adsorption rates for PSPMA and the glycopolymer are seen to be highly surface sensitive, with significantly higher rates on cellulose-modified surfaces, whereas PAA shows a much smaller rate dependence on the nature of the adsorption surface.

  19. Carbon isotope analysis of dissolved organic carbon in fresh and saline (NaCl) water via continuous flow cavity ring-down spectroscopy following wet chemical oxidation

    USGS Publications Warehouse

    Conaway, Christopher; Thomas, Randal B.; Saad, Nabil; Thordsen, James J.; Kharaka, Yousif K.

    2015-01-01

    This work examines the performance and limitations of a wet chemical oxidation carbon analyser interfaced with a cavity ring-down spectrometer (WCO-CRDS) in a continuous flow (CF) configuration for measuring δ13C of dissolved organic carbon (δ13C-DOC) in natural water samples. Low-chloride matrix (<5 g Cl/L) DOC solutions were analysed with as little as 2.5 mg C/L in a 9 mL aliquot with a precision of 0.5 ‰. In high-chloride matrix (10–100 g Cl/L) DOC solutions, bias towards lighter δ13C-DOC was observed because of incomplete oxidation despite using high-concentration oxidant, extended reaction time, or post-wet chemical oxidation gas-phase combustion. However, through a combination of dilution, chloride removal, and increasing the oxidant:sample ratio, high-salinity samples with sufficient DOC (>22.5 µg C/aliquot) may be analysed. The WCO-CRDS approach requires more total carbon (µg C/aliquot) than conventional CF-isotope ratio mass spectrometer, but is nonetheless applicable to a wide range of DOC concentration and water types, including brackish water, produced water, and basinal brines.

  20. Conjugating precision and acquisition time in a Doppler broadening regime by interleaved frequency-agile rapid-scanning cavity ring-down spectroscopy.

    PubMed

    Gotti, Riccardo; Gatti, Davide; Masłowski, Piotr; Lamperti, Marco; Belmonte, Michele; Laporta, Paolo; Marangoni, Marco

    2017-10-07

    We propose a novel approach to cavity-ring-down-spectroscopy (CRDS) in which spectra acquired with a frequency-agile rapid-scanning (FARS) scheme, i.e., with a laser sideband stepped across the modes of a high-finesse cavity, are interleaved with one another by a sub-millisecond readjustment of the cavity length. This brings to time acquisitions below 20 s for few-GHz-wide spectra composed of a very high number of spectral points, typically 3200. Thanks to the signal-to-noise ratio easily in excess of 10 000, each FARS-CRDS spectrum is shown to be sufficient to determine the line-centre frequency of a Doppler broadened line with a precision of 2 parts over 10 11 , thus very close to that of sub-Doppler regimes and in a few-seconds time scale. The referencing of the probe laser to a frequency comb provides absolute accuracy and long-term reproducibility to the spectrometer and makes it a powerful tool for precision spectroscopy and line-shape analysis. The experimental approach is discussed in detail together with experimental precision and accuracy tests on the (30 012) ← (00 001) P12e line of CO 2 at ∼1.57 μm.

  1. Applications of Cavity Ring-Down Spectroscopy (CRDS) to Analysis of Carbon Stable Isotope Composition of Groundwater

    NASA Astrophysics Data System (ADS)

    Jeong, T.; Woo, N. C.; Choi, H.

    2014-12-01

    Carbon Capture and Storage (CCS) has been considered as an effective strategy to reduce atmospheric carbon dioxide (CO2) concentration. However, unintended leakage of CO2 leakage from storage sites could occur through highly permeable conduits such as fractures in low-K formations during the injection and storage of SCCO2 (supercritical phase CO2). Therefore, prediction and detection of CO2 leakage and relevant analysis of carbon isotope are crucial to assure environmental and public safety. Until recently, Isotope Ratio Mass Spectrometry (IRMS) has been utilized to measure the stable isotope ratio of water. However, IRMS is time-consuming operation due to complicated pretreatment, and thus not a practical methodology under field conditions. Carbon Isotope Analyzer (CCIA), which is a kind of Cavity Ring-Down Spectroscopy (CRDS) and has a wide measurement range from 300 to 25000 ppmv, can facilitate the rate of measurements up to 1 Hz by using continuous flow method so that it can be readily applied to field. In this study, carbon stable isotope ratio of groundwater will be analyzed using CCIA. Then, the CCIA results will be compared with IRMS to validate its accuracy and stability. This research will provide an appropriate method for analyzing carbon stable isotope in groundwater, using a continuous flow mode.

  2. Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection

    PubMed Central

    Zhang, Qinduan; Chang, Jun; Wang, Zongliang; Wang, Fupeng; Qin, Zengguang

    2017-01-01

    We proposed a new method for gas detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser by merging a transmission PAS cell (resonant frequency f0 = 5.3 kHz) inside the fiber laser cavity. The Q-switching was achieved by an acousto-optic modulator, achieving a peak pulse power of ~679 mW in the case of the acousto-optic modulation signal with an optimized duty ratio of 10%. We used a custom-made fiber Bragg grating with a central wavelength of 1530.37 nm (the absorption peak of C2H2) to select the laser wavelength. The system achieved a linear response (R2 = 0.9941) in a concentration range from 400 to 7000 ppmv, and the minimum detection limit compared to that of a conventional intensity modulation system was enhanced by 94.2 times. PMID:29295599

  3. Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection.

    PubMed

    Zhang, Qinduan; Chang, Jun; Wang, Qiang; Wang, Zongliang; Wang, Fupeng; Qin, Zengguang

    2017-12-25

    We proposed a new method for gas detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser by merging a transmission PAS cell (resonant frequency f ₀ = 5.3 kHz) inside the fiber laser cavity. The Q-switching was achieved by an acousto-optic modulator, achieving a peak pulse power of ~679 mW in the case of the acousto-optic modulation signal with an optimized duty ratio of 10%. We used a custom-made fiber Bragg grating with a central wavelength of 1530.37 nm (the absorption peak of C₂H₂) to select the laser wavelength. The system achieved a linear response (R² = 0.9941) in a concentration range from 400 to 7000 ppmv, and the minimum detection limit compared to that of a conventional intensity modulation system was enhanced by 94.2 times.

  4. 77 FR 58437 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-20

    ... Rule Change and Amendments Nos. 1, 2, 3 and 4 Thereto, To Require Members To Provide Customers in TRACE...) of the Securities Exchange Act of 1934 (``Exchange Act'' or ``Act'') \\1\\ and Rule 19b-4 thereunder,\\2... Amendment No. 4 on August 21, 2007. The proposed rule change, as modified by Amendments 1, 2, 3 and 4, was...

  5. Omori Law After Exogenous Shocks on Supplier-Customer Network

    NASA Astrophysics Data System (ADS)

    Fujiwara, Yoshi

    We study the relaxation process of a supplier-customer network after mass destruction due to two giant earthquakes, Kobe 1995 and East Japan 2011, by investigating the number of chained failures. Firstly, a mass destruction and intervention of business activities in the damaged areas can be considered as a main shock. The exogenous shock was propagated on the supplier-customer network deteriorating financial states of other firms, even if they are not located in geographical neighbors. To quantify such aftershocks, we use chained failures on the network assuming that they indicate the trace of propagation of shocks. We show that the number of chained failures in its temporal change obeys an Omori-law, a power-law relaxation. This finding implies that the relaxation is much more sluggish than one would naively expect, and that it might be possible to estimate the extent and duration of aftershocks by using the empirical law. Several issues are discussed including the origin of the long-time relaxation.

  6. Enrichment of steroid hormones in water with porous and hydrophobic polymer-based SPE followed by HPLC-UV determination.

    PubMed

    Hu, Yinfen; Zhang, Man; Tong, Changlun; Wu, Jianmin; Liu, Weiping

    2013-10-01

    There have been great concerns about the persistence of steroid hormones in surface water. Since the concentrations of these compounds in water samples are usually at a trace level, the efficient enrichment of steroid hormones is vital for further analysis. In this work, a porous and hydrophobic polymer was synthesized and characterized. The composition of solvent used as porogen in the synthetic process was shown to have an effect on the morphology of the polymer, which was successfully used as an SPE sorbent for simultaneously enriching steroid hormones in surface water samples. The recoveries of the steroid hormones on the custom-made polymer ranged from 93.4 to 106.2%, whereas those on commercialized ENVI-18, LC-18, and Oasis HLB ranged from 54.8 to 104.9, 66 to 93.6, and 77.2 to 106%, respectively. Five types of steroid hormones were simultaneously measured using HPLC-UV after they were enriched by the custom-made sorbent. Based on these findings, the SPE-HPLC method was developed. The LODs of this method for estriol, estradiol, estrone, androstenedione, progesterone were 0.07, 0.43, 0.61, 0.27, and 0.42 μg/L, respectively, while precision and reproducibility RSDs were <6.40 and 7.49%, respectively. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Base stock system for patient vs impatient customers with varying demand distribution

    NASA Astrophysics Data System (ADS)

    Fathima, Dowlath; Uduman, P. Sheik

    2013-09-01

    An optimal Base-Stock inventory policy for Patient and Impatient Customers using finite-horizon models is examined. The Base stock system for Patient and Impatient customers is a different type of inventory policy. In case of the model I, Base stock for Patient customer case is evaluated using the Truncated Exponential Distribution. The model II involves the study of Base-stock inventory policies for Impatient customer. A study on these systems reveals that the Customers wait until the arrival of the next order or the customers leaves the system which leads to lost sale. In both the models demand during the period [0, t] is taken to be a random variable. In this paper, Truncated Exponential Distribution satisfies the Base stock policy for the patient customer as a continuous model. So far the Base stock for Impatient Customers leaded to a discrete case but, in this paper we have modeled this condition into a continuous case. We justify this approach mathematically and also numerically.

  8. Trace gas detection from fermentation processes in apples; an intercomparison study between proton-transfer-reaction mass spectrometry and laser photoacoustics

    NASA Astrophysics Data System (ADS)

    Boamfa, E. I.; Steeghs, M. M. L.; Cristescu, S. M.; Harren, F. J. M.

    2004-12-01

    A custom-built proton-transfer-reaction mass spectrometry (PTR-MS) instrument was used to monitor the emission of various compounds (aldehydes, alcohols, acids, acetates and C-6 compounds) related to fermentation, aroma and flavour, released by four apple cultivars (Elstar, Jonaglod, Granny Smith and Pink Lady) under short anaerobic (24 h) and post-anaerobic conditions. The novel feature of our instrument is the new design of the collisional dissociation chamber, which separates the high pressure in the drift tube (2 mbar) from the high vacuum pressure in the detection region (10-6 mbar). The geometry of this chamber was changed and a second turbo pump was added to reduce the influence of collisional loss of ions, background signals and cluster ions, which facilitates the interpretation of the mass spectra and increases the signal intensity at the mass of the original protonated compound. With this system, detection limits of similar magnitude to the ones reported in literature are reached. An intercomparison study between PTR-MS and a CO laser-based photoacoustic trace gas detector is presented. The alcoholic fermentation products (acetaldehyde and ethanol) from young rice plants were simultaneously monitored by both methods. A very good agreement was observed for acetaldehyde production. The photoacoustic detector showed about two times lower ethanol concentration as compared to PTR-MS, caused by memory effects due to sticking of compounds to the walls of the nylon tube used to transport the trace gases to the detector.

  9. Infrared Spectroscopy with a Cavity Ring-Down Spectrometer

    DTIC Science & Technology

    2014-08-01

    excitation source wavelength. This relationship is the Beer - Lambert law that describes electromagnetic radiation spectroscopy: (2) We can...absorption coefficient on the right. The modified Beer - Lambert law in Eq. 6 is used in the numerical analysis of data collected by the CRDS. The...take Beer - Lambert and express the fraction of transmitted light (I/I0) on the left-hand side of Eq. 2 as a function of time. This expression is

  10. Energy optimization system

    DOEpatents

    Zhou, Zhi; de Bedout, Juan Manuel; Kern, John Michael; Biyik, Emrah; Chandra, Ramu Sharat

    2013-01-22

    A system for optimizing customer utility usage in a utility network of customer sites, each having one or more utility devices, where customer site is communicated between each of the customer sites and an optimization server having software for optimizing customer utility usage over one or more networks, including private and public networks. A customer site model for each of the customer sites is generated based upon the customer site information, and the customer utility usage is optimized based upon the customer site information and the customer site model. The optimization server can be hosted by an external source or within the customer site. In addition, the optimization processing can be partitioned between the customer site and an external source.

  11. Guaranteeing the quality and integrity of pork - An Australian case study.

    PubMed

    Channon, H A; D'Souza, D N; Jarrett, R G; Lee, G S H; Watling, R J; Jolley, J Y C; Dunshea, F R

    2018-04-27

    The Australian pork industry is strongly committed to assuring the integrity of its product, with substantial research investment made over the past ten years to develop and implement systems to assure the consistency and quality of fresh pork and to enable accurate tracing of unpackaged fresh pork back to property of origin using trace elemental profiling. These initiatives are pivotal to allow Australian pork of guaranteed eating quality to be successfully positioned as higher value products, across a range of international and domestic markets, whilst managing any threats of product substitution. This paper describes the current status of the development of a predictive eating quality model for Australian pork, utilizing eating quality datasets generated from recent Australian studies. The implementation of trace elemental profiling, by Physi-Trace™, to verify and defend provenance claims and support the supply of consistently high eating quality Australian pork to its customers, is also discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Comb-assisted cavity ring down spectroscopy of 17O enriched water between 7443 and 7921 cm-1

    NASA Astrophysics Data System (ADS)

    Mondelain, D.; Mikhailenko, S. N.; Karlovets, E. V.; Béguier, S.; Kassi, S.; Campargue, A.

    2017-12-01

    The room temperature absorption spectrum of water vapor highly enriched in 17O has been recorded by Cavity Ring Down Spectroscopy (CRDS) between 7443 and 7921 cm-1. Three series of recordings were performed with pressure values around 0.1, 1 and 10 Torr. The frequency calibration of the present spectra benefited of the combination of the CRDS spectrometer to a self-referenced frequency comb. The resulting CRD spectrometer combines excellent frequency accuracy over a broad spectral region with a high sensitivity (Noise Equivalent Absorption, αmin∼ 10-11-10-10 cm-1). The investigated spectral region corresponds to the high energy range of the first hexade. The assignments were performed using known experimental energy levels as well as calculated line lists based on the results of Partridge and Schwenke. Overall about 4150 lines were measured and assigned to 4670 transitions of six water isotopologues (H216O, H217O, H218O, HD16O, HD17O and HD18O). Their intensities span six orders of magnitude from 10-28 to 10-22 cm/molecule. Most of the new results concern the H217O and HD17O isotopologues for which about 1600 and 400 transitions were assigned leading to the determination of 329 and 207 new energy levels, respectively. For comparison only about 300 and four transitions of H217O and HD17O were previously known in the region, respectively. By comparison to highly accurate H216O line positions available in the literature, the average accuracy on our line centers is checked to be on the order of 3 MHz (10-4 cm-1) or better for not weak well isolated lines. This small uncertainty represents a significant improvement of the line center determination of many H216O lines included in the experimental list provided as Supplementary Material.

  13. Plume mapping and isotopic characterisation of anthropogenic methane sources

    NASA Astrophysics Data System (ADS)

    Zazzeri, G.; Lowry, D.; Fisher, R. E.; France, J. L.; Lanoisellé, M.; Nisbet, E. G.

    2015-06-01

    Methane stable isotope analysis, coupled with mole fraction measurement, has been used to link isotopic signature to methane emissions from landfill sites, coal mines and gas leaks in the United Kingdom. A mobile Picarro G2301 CRDS (Cavity Ring-Down Spectroscopy) analyser was installed on a vehicle, together with an anemometer and GPS receiver, to measure atmospheric methane mole fractions and their relative location while driving at speeds up to 80 kph. In targeted areas, when the methane plume was intercepted, air samples were collected in Tedlar bags, for δ13C-CH4 isotopic analysis by CF-GC-IRMS (Continuous Flow Gas Chromatography-Isotope Ratio Mass Spectrometry). This method provides high precision isotopic values, determining δ13C-CH4 to ±0.05 per mil. The bulk signature of the methane plume into the atmosphere from the whole source area was obtained by Keeling plot analysis, and a δ13C-CH4 signature, with the relative uncertainty, allocated to each methane source investigated. Both landfill and natural gas emissions in SE England have tightly constrained isotopic signatures. The averaged δ13C-CH4 for landfill sites is -58 ± 3‰. The δ13C-CH4 signature for gas leaks is also fairly constant around -36 ± 2‰, a value characteristic of homogenised North Sea supply. In contrast, signatures for coal mines in N. England and Wales fall in a range of -51.2 ± 0.3‰ to -30.9 ± 1.4‰, but can be tightly constrained by region. The study demonstrates that CRDS-based mobile methane measurement coupled with off-line high precision isotopic analysis of plume samples is an efficient way of characterising methane sources. It shows that isotopic measurements allow type identification, and possible location of previously unknown methane sources. In modelling studies this measurement provides an independent constraint to determine the contributions of different sources to the regional methane budget and in the verification of inventory source distribution.

  14. Dynamic Measurements of Greenhouse Gas Respirations Caused by Changing Oxygen Levels

    NASA Astrophysics Data System (ADS)

    Fleck, D.; Saad, N.

    2015-12-01

    The necessity for constant monitoring of greenhouse gases (GHGs) is clearly evident now more than ever. Moreover, interpreting and understanding the processes that dictate the production and consumption of these gases will allow for proper management of GHGs in order to mitigate its detrimental climate effects. Presence of oxygen, or lack of it, is the driving force for determining pathways within biochemical redox reactions. Experiments to find correlations between oxygen and greenhouse gases have helped us understand photosynthesis, denitrification and beyond. Within the past few years measurements of O2 and nitrous oxide have been used over a wide ranging array of disciplines; from studying avenues for redox chemistry to characterizing gas profiles in sputum of cystic fibrosis patients. We present a full analysis solution, based on cavity ring-down spectroscopy, for simultaneous measurements of N2O, CO2, CH4, H2O, NH3, and O2 concentrations in soil flux, in order to better understand dynamics of ecological and biogeochemical processes. The stability and high temporal resolution of the five-species CRDS analyzer, coupled with a continuous high-precision O2 measurement (1-σ <200ppm) produces a complete picture of biogeochemical processes, for which a multitude of additional research experiments can be conceived. Adding another dimension to explore to help determine the rate at which these greenhouse gases are produced or consumed, allows scientists to further address fundamental scientific questions. Data is presented showing precision, drift and limitations of the O2 sensor measurement as well as the validity of spectroscopic corrections with the CRDS analyzer caused by changing O2. Experimental data is also presented to explore correlations of soil respiration rates of N2O, CO2 and CH4 due to differing soil O2 contents at varying timescales from minutes to days.

  15. Evaluation of the accuracy of thermal dissociation CRDS and LIF techniques for atmospheric measurement of reactive nitrogen species

    NASA Astrophysics Data System (ADS)

    Womack, Caroline C.; Neuman, J. Andrew; Veres, Patrick R.; Eilerman, Scott J.; Brock, Charles A.; Decker, Zachary C. J.; Zarzana, Kyle J.; Dube, William P.; Wild, Robert J.; Wooldridge, Paul J.; Cohen, Ronald C.; Brown, Steven S.

    2017-05-01

    The sum of all reactive nitrogen species (NOy) includes NOx (NO2 + NO) and all of its oxidized forms, and the accurate detection of NOy is critical to understanding atmospheric nitrogen chemistry. Thermal dissociation (TD) inlets, which convert NOy to NO2 followed by NO2 detection, are frequently used in conjunction with techniques such as laser-induced fluorescence (LIF) and cavity ring-down spectroscopy (CRDS) to measure total NOy when set at > 600 °C or speciated NOy when set at intermediate temperatures. We report the conversion efficiency of known amounts of several representative NOy species to NO2 in our TD-CRDS instrument, under a variety of experimental conditions. We find that the conversion efficiency of HNO3 is highly sensitive to the flow rate and the residence time through the TD inlet as well as the presence of other species that may be present during ambient sampling, such as ozone (O3). Conversion of HNO3 at 400 °C, nominally the set point used to selectively convert organic nitrates, can range from 2 to 6 % and may represent an interference in measurement of organic nitrates under some conditions. The conversion efficiency is strongly dependent on the operating characteristics of individual quartz ovens and should be well calibrated prior to use in field sampling. We demonstrate quantitative conversion of both gas-phase N2O5 and particulate ammonium nitrate in the TD inlet at 650 °C, which is the temperature normally used for conversion of HNO3. N2O5 has two thermal dissociation steps, one at low temperature representing dissociation to NO2 and NO3 and one at high temperature representing dissociation of NO3, which produces exclusively NO2 and not NO. We also find a significant interference from partial conversion (5-10 %) of NH3 to NO at 650 °C in the presence of representative (50 ppbv) levels of O3 in dry zero air. Although this interference appears to be suppressed when sampling ambient air, we nevertheless recommend regular characterization of this interference using standard additions of NH3 to TD instruments that convert reactive nitrogen to NO or NO2.

  16. 15 CFR 292.4 - Information infrastructure projects.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... customer base. The target customer base must be clearly defined and, in general, will be technical... evaluation for assessing outcomes of the activity, and “customer satisfaction” measures of performance. ... the customer base's needs within the proposed project area. The proposal should also show that the...

  17. The Kinetics and Dynamics of Elementary Gas-Phase Reactions

    DTIC Science & Technology

    2002-09-01

    We report CRDS measurements of thin films of oxazine 1, oxazine 170 and malachite green dyes deposited on borosilicate substrates. The method...measure monolayer and sub-monolayer quantities of dye. The minimum observed concentration of malachite green in the present work was calculated to be...the dyes: at surface coverages of ~ 2.8 × 10-7 mol m-2, the ratio of malachite green dimers to monomers was estimated as Cd/Cm = 0.22. The Kinetics

  18. European Non-Communicable Respiratory Disease Research, 2002-13: Bibliometric Study of Outputs and Funding

    PubMed Central

    Wright, John S. F.; Pallari, Elena; Sullivan, Richard

    2016-01-01

    This study was conducted in order to map European research in chronic respiratory diseases (CRDs). It was intended to assist the European Commission and other research funders to identify gaps and overlaps in their portfolios, and to suggest ways in which they could improve the effectiveness of their support and increase the impact of the research on patient care and on the reduction of the incidence of the CRDs. Articles and reviews were identified in the Web of Science on research in six non-communicable respiratory diseases that were published in 2002–13 from 31 European countries. They represented only 0.8% of biomedical research output but these diseases accounted for 4.7% of the European disease burden, as measured by Disability-Adjusted Life Years (DALYs), so the sub-field is seriously under-researched. Europe is prominent in the sub-field and published 56% of the world total, with the UK the most productive and publishing more than France and Italy, the next two countries, combined. Asthma and Chronic Obstructive Pulmonary Disease (COPD) were the diseases with the most publications and the highest citation rates. They also received the most funding, with around two acknowledgments per paper (in 2009–13), whereas cystic fibrosis and emphysema averaged only one. Just over 37% of papers had no specific funding and depended on institutional support from universities and hospitals. PMID:27111670

  19. Hybrid-PIC Modeling of the Transport of Atomic Boron in a Hall Thruster

    NASA Technical Reports Server (NTRS)

    Smith, Brandon D.; Boyd, Iaian D.; Kamhawi, Hani

    2015-01-01

    Computational analysis of the transport of boron eroded from the walls of a Hall thruster is performed by implementing sputter yields of hexagonal boron nitride and velocity distribution functions of boron within the hybrid-PIC model HPHall. The model is applied to simulate NASA's HiVHAc Hall thruster at a discharge voltage of 500V and discharge powers of 1-3 kW. The number densities of ground- and 4P-state boron are computed. The density of ground-state boron is shown to be a factor of about 30 less than the plasma density. The density of the excited state is shown to be about three orders of magnitude less than that of the ground state, indicating that electron impact excitation does not significantly affect the density of ground-state boron in the discharge channel or near-field plume of a Hall thruster. Comparing the rates of excitation and ionization suggests that ionization has a greater influence on the density of ground-state boron, but is still negligible. The ground-state boron density is then integrated and compared to cavity ring-down spectroscopy (CRDS) measurements for each operating point. The simulation results show good agreement with the measurements for all operating points and provide evidence in support of CRDS as a tool for measuring Hall thruster erosion in situ.

  20. Fabrication and testing of a standoff trace explosives detection system

    NASA Astrophysics Data System (ADS)

    Waterbury, Robert; Rose, Jeremy; Vunck, Darius; Blank, Thomas; Pohl, Ken; Ford, Alan; McVay, Troy; Dottery, Ed

    2011-05-01

    In order to stop the transportation of materials used for IED manufacture, a standoff checkpoint explosives detection system (CPEDS) has recently been fabricated. The system incorporates multi-wavelength Raman spectroscopy and laser induced breakdown spectroscopy (LIBS) modalities with a LIBS enhancement technique called TEPS to be added later into a single unit for trace detection of explosives at military checkpoints. Newly developed spectrometers and other required sensors all integrated with a custom graphical user interface for producing simplified, real-time detection results are also included in the system. All equipment is housed in a military ruggedized shelter for potential deployment intheater for signature collection. Laboratory and performance data, as well as the construction of the CPEDS system and its potential deployment capabilities, will be presented in the current work.

  1. A Framework to Improve Energy Efficient Behaviour at Home through Activity and Context Monitoring

    PubMed Central

    García, Óscar; Alonso, Ricardo S.; Corchado, Juan M.

    2017-01-01

    Real-time Localization Systems have been postulated as one of the most appropriated technologies for the development of applications that provide customized services. These systems provide us with the ability to locate and trace users and, among other features, they help identify behavioural patterns and habits. Moreover, the implementation of policies that will foster energy saving in homes is a complex task that involves the use of this type of systems. Although there are multiple proposals in this area, the implementation of frameworks that combine technologies and use Social Computing to influence user behaviour have not yet reached any significant savings in terms of energy. In this work, the CAFCLA framework (Context-Aware Framework for Collaborative Learning Applications) is used to develop a recommendation system for home users. The proposed system integrates a Real-Time Localization System and Wireless Sensor Networks, making it possible to develop applications that work under the umbrella of Social Computing. The implementation of an experimental use case aided efficient energy use, achieving savings of 17%. Moreover, the conducted case study pointed to the possibility of attaining good energy consumption habits in the long term. This can be done thanks to the system’s real time and historical localization, tracking and contextual data, based on which customized recommendations are generated. PMID:28758987

  2. Improving atomic force microscopy imaging by a direct inverse asymmetric PI hysteresis model.

    PubMed

    Wang, Dong; Yu, Peng; Wang, Feifei; Chan, Ho-Yin; Zhou, Lei; Dong, Zaili; Liu, Lianqing; Li, Wen Jung

    2015-02-03

    A modified Prandtl-Ishlinskii (PI) model, referred to as a direct inverse asymmetric PI (DIAPI) model in this paper, was implemented to reduce the displacement error between a predicted model and the actual trajectory of a piezoelectric actuator which is commonly found in AFM systems. Due to the nonlinearity of the piezoelectric actuator, the standard symmetric PI model cannot precisely describe the asymmetric motion of the actuator. In order to improve the accuracy of AFM scans, two series of slope parameters were introduced in the PI model to describe both the voltage-increase-loop (trace) and voltage-decrease-loop (retrace). A feedforward controller based on the DIAPI model was implemented to compensate hysteresis. Performance of the DIAPI model and the feedforward controller were validated by scanning micro-lenses and standard silicon grating using a custom-built AFM.

  3. Custom-oriented wavefront sensor for human eye properties measurements

    NASA Astrophysics Data System (ADS)

    Galetskiy, Sergey; Letfullin, Renat; Dubinin, Alex; Cherezova, Tatyana; Belyakov, Alexey; Kudryashov, Alexis

    2005-12-01

    The problem of correct measurement of human eye aberrations is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). In this paper we show capabilities to measure aberrations by means of the aberrometer built in our lab together with Active Optics Ltd. We discuss the calibration of the aberrometer and show invalidity to use for the ophthalmic calibration purposes the analytical equation based on thin lens formula. We show that proper analytical equation suitable for calibration should have dependence on the square of the distance increment and we illustrate this both by experiment and by Zemax Ray tracing modeling. Also the error caused by inhomogeneous intensity distribution of the beam imaged onto the aberrometer's Shack-Hartmann sensor is discussed.

  4. The high-resolution infrared spectrum of the ν3 +ν5 combination band of jet-cooled propyne

    NASA Astrophysics Data System (ADS)

    Doney, K. D.; Zhao, D.; Bouwman, J.; Linnartz, H.

    2017-09-01

    We present the first detection of the high-resolution ro-vibrational spectrum of the ν3 +ν5 combination band of propyne around 3070 cm-1. The fully resolved spectrum is recorded for supersonically jet-cooled propyne using continuous wave cavity ring-down spectroscopy (cw-CRDS). The assignments are supported with the help of accurate ab initio vibration-rotation interaction constants (αi) and anharmonic frequencies. A detailed analysis of the rotationally cold spectrum is given.

  5. Effects of customization on application decisions and applicant pool characteristics in a web-based recruitment context.

    PubMed

    Dineen, Brian R; Noe, Raymond A

    2009-01-01

    The authors examined 2 forms of customization in a Web-based recruitment context. Hypotheses were tested in a controlled study in which participants viewed multiple Web-based job postings that each included information about multiple fit categories. Results indicated that customization of information regarding person-organization (PO), needs-supplies, and demands-abilities (DA) fit (fit information customization) and customization of the order in which these fit categories were presented (configural customization) had differential effects on outcomes. Specifically, (a) applicant pool PO and DA fit were greater when fit information customization was provided, (b) applicant pool fit in high- versus low-relevance fit categories was better differentiated when configural customization was provided, and (c) overall application rates were lower when either or both forms of customization were provided. (PsycINFO Database Record (c) 2009 APA, all rights reserved).

  6. Cell Surface Display of Four Types of Solanum nigrum Metallothionein on Saccharomyces cerevisiae for Biosorption of Cadmium.

    PubMed

    Wei, Qinguo; Zhang, Honghai; Guo, Dongge; Ma, Shisheng

    2016-05-28

    We displayed four types of Solanum nigrum metallothionein (SMT) for the first time on the surface of Saccharomyces cerevisiae using an α-agglutinin-based display system. The SMT genes were amplified by RT-PCR. The plasmid pYES2 was used to construct the expression vector. Transformed yeast strains were confirmed by PCR amplification and custom sequencing. Surface-expressed metallothioneins were indirectly indicated by the enhanced cadmium sorption capacity. Flame atomic absorption spectrophotometry was used to examine the concentration of Cd(2+) in this study. The transformed yeast strains showed much higher resistance ability to Cd(2+) compared with the control. Strikingly, their Cd(2+) accumulation was almost twice as much as that of the wild-type yeast cells. Furthermore, surface-engineered yeast strains could effectively adsorb ultra-trace cadmium and accumulate Cd(2+) under a wide range of pH levels, from 3 to 7, without disturbing the Cu(2+) and Hg(2+). Four types of surfaceengineered Saccharomyces cerevisiae strains were constructed and they could be used to purify Cd(2+)-contaminated water and adsorb ultra-trace cadmium effectively. The surface-engineered Saccharomyces cerevisiae strains would be useful tools for the bioremediation and biosorption of environmental cadmium contaminants.

  7. Spitzer/JWST Cross Calibration: IRAC Observations of Potential Calibrators for JWST

    NASA Astrophysics Data System (ADS)

    Carey, Sean J.; Gordon, Karl D.; Lowrance, Patrick; Ingalls, James G.; Glaccum, William J.; Grillmair, Carl J.; E Krick, Jessica; Laine, Seppo J.; Fazio, Giovanni G.; Hora, Joseph L.; Bohlin, Ralph

    2017-06-01

    We present observations at 3.6 and 4.5 microns using IRAC on the Spitzer Space Telescope of a set of main sequence A stars and white dwarfs that are potential calibrators across the JWST instrument suite. The stars range from brightnesses of 4.4 to 15 mag in K band. The calibration observations use a similar redundancy to the observing strategy for the IRAC primary calibrators (Reach et al. 2005) and the photometry is obtained using identical methods and instrumental photometric corrections as those applied to the IRAC primary calibrators (Carey et al. 2009). The resulting photometry is then compared to the predictions based on spectra from the CALSPEC Calibration Database (http://www.stsci.edu/hst/observatory/crds/calspec.html) and the IRAC bandpasses. These observations are part of an ongoing collaboration between IPAC and STScI investigating absolute calibration in the infrared.

  8. Measurements of carbon-14 with cavity ring-down spectroscopy

    DOE PAGES

    McCartt, A. D.; Ognibene, T.; Bench, G.; ...

    2015-06-13

    Accelerator Mass Spectrometry (AMS) is the most sensitive method for quantitation of 14C in biological samples. This technology has been used in a variety of low dose, human health related studies over the last 20 years when very high sensitivity was needed. AMS helped pioneer these scientific methods, but its expensive facilities and requirements for highly trained technical staff have limited their proliferation. Quantification of 14C by cavity ring-down spectroscopy (CRDS) offers an approach that eliminates many of the shortcomings of an accelerator-based system and would supplement the use of AMS in biomedical research. Our initial prototype, using a non-idealmore » wavelength laser and under suboptimal experimental conditions, has a 3.5-modern, 1-σ precision for detection of milligram-sized, carbon-14-elevated samples. Furthermore, these results demonstrate proof of principle and provided a starting point for the development of a spectrometer capable of biologically relevant sensitivities.« less

  9. CoCoMac 2.0 and the future of tract-tracing databases

    PubMed Central

    Bakker, Rembrandt; Wachtler, Thomas; Diesmann, Markus

    2012-01-01

    The CoCoMac database contains the results of several hundred published axonal tract-tracing studies in the macaque monkey brain. The combined results are used for constructing the macaque macro-connectome. Here we discuss the redevelopment of CoCoMac and compare it to six connectome-related projects: two online resources that provide full access to raw tracing data in rodents, a connectome viewer for advanced 3D graphics, a partial but highly detailed rat connectome, a brain data management system that generates custom connectivity matrices, and a software package that covers the complete pipeline from connectivity data to large-scale brain simulations. The second edition of CoCoMac features many enhancements over the original. For example, a search wizard is provided for full access to all tables and their nested dependencies. Connectivity matrices can be computed on demand in a user-selected nomenclature. A new data entry system is available as a preview, and is to become a generic solution for community-driven data entry in manually collated databases. We conclude with the question whether neuronal tracing will remain the gold standard to uncover the wiring of brains, thereby highlighting developments in human connectome construction, tracer substances, polarized light imaging, and serial block-face scanning electron microscopy. PMID:23293600

  10. CoCoMac 2.0 and the future of tract-tracing databases.

    PubMed

    Bakker, Rembrandt; Wachtler, Thomas; Diesmann, Markus

    2012-01-01

    The CoCoMac database contains the results of several hundred published axonal tract-tracing studies in the macaque monkey brain. The combined results are used for constructing the macaque macro-connectome. Here we discuss the redevelopment of CoCoMac and compare it to six connectome-related projects: two online resources that provide full access to raw tracing data in rodents, a connectome viewer for advanced 3D graphics, a partial but highly detailed rat connectome, a brain data management system that generates custom connectivity matrices, and a software package that covers the complete pipeline from connectivity data to large-scale brain simulations. The second edition of CoCoMac features many enhancements over the original. For example, a search wizard is provided for full access to all tables and their nested dependencies. Connectivity matrices can be computed on demand in a user-selected nomenclature. A new data entry system is available as a preview, and is to become a generic solution for community-driven data entry in manually collated databases. We conclude with the question whether neuronal tracing will remain the gold standard to uncover the wiring of brains, thereby highlighting developments in human connectome construction, tracer substances, polarized light imaging, and serial block-face scanning electron microscopy.

  11. Greenhouse gas measurements from a UK network of tall towers: technical description and first results

    NASA Astrophysics Data System (ADS)

    Stanley, Kieran M.; Grant, Aoife; O'Doherty, Simon; Young, Dickon; Manning, Alistair J.; Stavert, Ann R.; Spain, T. Gerard; Salameh, Peter K.; Harth, Christina M.; Simmonds, Peter G.; Sturges, William T.; Oram, David E.; Derwent, Richard G.

    2018-03-01

    A network of three tall tower measurement stations was set up in 2012 across the United Kingdom to expand measurements made at the long-term background northern hemispheric site, Mace Head, Ireland. Reliable and precise in situ greenhouse gas (GHG) analysis systems were developed and deployed at three sites in the UK with automated instrumentation measuring a suite of GHGs. The UK Deriving Emissions linked to Climate Change (UK DECC) network uses tall (165-230 m) open-lattice telecommunications towers, which provide a convenient platform for boundary layer trace gas sampling. In this paper we describe the automated measurement system and first results from the UK DECC network for CO2, CH4, N2O, SF6, CO and H2. CO2 and CH4 are measured at all of the UK DECC sites by cavity ring-down spectroscopy (CRDS) with multiple inlet heights at two of the three tall tower sites to assess for boundary layer stratification. The short-term precisions (1σ on 1 min means) of CRDS measurements at background mole fractions for January 2012 to September 2015 is < 0.05 µmol mol-1 for CO2 and < 0.3 nmol mol-1 for CH4. Repeatability of standard injections (1σ) is < 0.03 µmol mol-1 for CO2 and < 0.3 nmol mol-1 for CH4 for the same time period. N2O and SF6 are measured at three of the sites, and CO and H2 measurements are made at two of the sites, from a single inlet height using gas chromatography (GC) with an electron capture detector (ECD), flame ionisation detector (FID) or reduction gas analyser (RGA). Repeatability of individual injections (1σ) on GC and RGA instruments between January 2012 and September 2015 for CH4, N2O, SF6, CO and H2 measurements were < 2.8 nmol mol-1, < 0.4 nmol mol-1, < 0.07 pmol mol-1, < 2 nmol mol-1 and < 3 nmol mol-1, respectively. Instrumentation in the network is fully automated and includes sensors for measuring a variety of instrumental parameters such as flow, pressures, and sampling temperatures. Automated alerts are generated and emailed to site operators when instrumental parameters are not within defined set ranges. Automated instrument shutdowns occur for critical errors such as carrier gas flow rate deviations. Results from the network give good spatial and temporal coverage of atmospheric mixing ratios within the UK since early 2012. Results also show that all measured GHGs are increasing in mole fraction over the selected reporting period and, except for SF6, exhibit a seasonal trend. CO2 and CH4 also show strong diurnal cycles, with night-time maxima and daytime minima in mole fractions.

  12. Repeat Customer Success in Extension

    ERIC Educational Resources Information Center

    Bess, Melissa M.; Traub, Sarah M.

    2013-01-01

    Four multi-session research-based programs were offered by two Extension specialist in one rural Missouri county. Eleven participants who came to multiple Extension programs could be called "repeat customers." Based on the total number of participants for all four programs, 25% could be deemed as repeat customers. Repeat customers had…

  13. Mining Rare Events Data for Assessing Customer Attrition Risk

    NASA Astrophysics Data System (ADS)

    Au, Tom; Chin, Meei-Ling Ivy; Ma, Guangqin

    Customer attrition refers to the phenomenon whereby a customer leaves a service provider. As competition intensifies, preventing customers from leaving is a major challenge to many businesses such as telecom service providers. Research has shown that retaining existing customers is more profitable than acquiring new customers due primarily to savings on acquisition costs, the higher volume of service consumption, and customer referrals. For a large enterprise, its customer base consists of tens of millions service subscribers, more often the events, such as switching to competitors or canceling services are large in absolute number, but rare in percentage, far less than 5%. Based on a simple random sample, popular statistical procedures, such as logistic regression, tree-based method and neural network, can sharply underestimate the probability of rare events, and often result a null model (no significant predictors). To improve efficiency and accuracy for event probability estimation, a case-based data collection technique is then considered. A case-based sample is formed by taking all available events and a small, but representative fraction of nonevents from a dataset of interest. In this article we showed a consistent prior correction method for events probability estimation and demonstrated the performance of the above data collection techniques in predicting customer attrition with actual telecommunications data.

  14. Simplified mathematics for customized refractive surgery.

    PubMed

    Preussner, Paul Rolf; Wahl, Jochen

    2003-03-01

    To describe a simple mathematical approach to customized corneal refractive surgery or customized intraocular lens (IOL) design that allows "hypervision" and to investigate the accuracy limits. University eye hospital, Mainz, Germany. Corneal shape and at least 1 IOL surface are approximated by the well-known Cartesian conic section curves (ellipsoid, paraboloid, or hyperboloid). They are characterized by only 2 parameters, the vertex radius and the numerical eccentricity. Residual refraction errors for this approximation are calculated by numerical ray tracing. These errors can be displayed as a 2-dimensional refraction map across the pupil or by blurring the image of a Landolt ring superimposed on the retinal receptor grid, giving an overall impression of the visual outcome. If the eye is made emmetropic for paraxial rays and if the numerical eccentricities of the cornea and lens are appropriately fitted to each other, the residual refractive errors are small enough to allow hypervision. Visual acuity of at least 2.0 (20/10) appears to be possible, particularly for mesopic pupil diameters. However, customized optics may have limited application due to their sensitivity to misalignment errors such as decentrations or rotations. The mathematical approach described by Descartes 350 years ago is adequate to calculate hypervision optics for the human eye. The availability of suitable mathematical tools should, however, not be viewed with too much optimism as long as the accuracy of the implementation in surgical procedures is limited.

  15. The CO2 absorption spectrum in the 2.3 μm transparency window by high sensitivity CRDS: (II) Self-absorption continuum

    NASA Astrophysics Data System (ADS)

    Mondelain, D.; Vasilchenko, S.; Čermák, P.; Kassi, S.; Campargue, A.

    2017-01-01

    The CO2 absorption continuum near 2.3 μm is determined for a series of sub atmospheric pressures (250-750 Torr) by high sensitivity Cavity Ring Down Spectroscopy. An experimental procedure consisting in injecting successively a gas flow of CO2 and synthetic air, keeping constant the gas pressure in the CRDS cell, has been developed. This procedure insures a high stability of the spectra baseline by avoiding changes of the optical alignment due to pressure changes. The CO2 continuum was obtained as the difference between the CO2 absorption coefficient and a local lines simulation using a Voigt profile truncated at ±25 cm-1. Following the results of the preceding analysis of the CO2 rovibrational lines (Vasilchenko S et al. J Quant Spectrosc Radiat Transfer 10.1016/j.jqsrt.2016.07.002, a CO2 line list with intensities obtained by variational calculations and empirical line positions was preferred to the HITRAN line list. A quadratic pressure dependence of the absorption continuum is observed, with an average binary absorption coefficient increasing from 2 to 4×10-8 cm-1 amagat-2 between 4320 and 4380 cm-1. The obtained continuum is found in good agreement with a previous measurement using much higher densities (20 amagat) and a low resolution grating spectrograph and is consistent with values currently used in the analysis of Venus spectra.

  16. Structural Basis for Carbohydrate Recognition and Anti-inflammatory Modulation by Gastrointestinal Nematode Parasite Toxascaris leonina Galectin*

    PubMed Central

    Hwang, Eun Young; Jeong, Mi Suk; Park, Sang Kyun; Ha, Sung Chul; Yu, Hak Sun; Jang, Se Bok

    2016-01-01

    Toxascaris leonina galectin (Tl-gal) is a galectin-9 homologue protein isolated from an adult worm of the canine gastrointestinal nematode parasite, and Tl-gal-vaccinated challenge can inhibit inflammation in inflammatory bowel disease-induced mice. We determined the first X-ray structures of full-length Tl-gal complexes with carbohydrates (lactose, N-acetyllactosamine, lacto-N-tetraose, sialyllactose, and glucose). Bonds were formed on concave surfaces of both carbohydrate recognition domains (CRDs) in Tl-gal. All binding sites were found in the HXXXR and WGXEER motifs. Charged Arg61/Arg196 and Glu80/Glu215 on the conserved motif of Tl-gal N-terminal CRD and C-terminal CRD are critical amino acids for recognizing carbohydrate binding, and the residues can affect protein folding and structure. The polar amino acids His, Asn, and Trp are also important residues for the interaction with carbohydrates through hydrogen bonding. Hemagglutination activities of Tl-gal were inhibited by interactions with carbohydrates and mutations. We found that the mutation of Tl-gal (E80A/E215A) at the carbohydrate binding region induced protein aggregation and could be caused in many diseases. The short linker region between the N-terminal and C-terminal CRDs of Tl-gal was very stable against proteolysis and maintained its biological activity. This structural information is expected to elucidate the carbohydrate recognition mechanism of Tl-gal and improve our understanding of anti-inflammatory mediators and modulators of immune response. PMID:27742836

  17. Address tracing for parallel machines

    NASA Technical Reports Server (NTRS)

    Stunkel, Craig B.; Janssens, Bob; Fuchs, W. Kent

    1991-01-01

    Recently implemented parallel system address-tracing methods based on several metrics are surveyed. The issues specific to collection of traces for both shared and distributed memory parallel computers are highlighted. Five general categories of address-trace collection methods are examined: hardware-captured, interrupt-based, simulation-based, altered microcode-based, and instrumented program-based traces. The problems unique to shared memory and distributed memory multiprocessors are examined separately.

  18. Comparison of continuous in-situ CO2 observations at Jungfraujoch using two different measurement techniques

    NASA Astrophysics Data System (ADS)

    Schibig, M. F.; Steinbacher, M.; Buchmann, B.; van der Laan-Luijkx, I. T.; van der Laan, S.; Ranjan, S.; Leuenberger, M. C.

    2014-07-01

    Since 2004, atmospheric carbon dioxide (CO2) is measured at the High Altitude Research Station Jungfraujoch by the division of Climate and Environmental Physics at the University of Bern (KUP) using a nondispersive infrared gas analyzer (NDIR) in combination with a paramagnetic O2 analyzer. In January 2010, CO2 measurements based on cavity ring down spectroscopy (CRDS) as part of the Swiss National Air Pollution Monitoring Network have been added by the Swiss Federal Laboratories for Materials Science and Technology (Empa). To ensure a smooth transition - a prerequisite when merging two datasets e.g. for trend determinations - the two measurement systems run in parallel for several years. Such a long-term intercomparison also allows identifying potential offsets between the two datasets and getting information about the compatibility of the two systems on different time scales. A good agreement of the seasonality as well as for the short-term variations was observed and to a lesser extent for trend calculations mainly due to the short common period. However, the comparison revealed some issues related to the stability of the calibration gases of the KUP system and their assigned CO2 mole fraction. It was possible to adapt an improved calibration strategy based on standard gas determinations, which lead to better agreement between the two data sets. By excluding periods with technical problems and bad calibration gas cylinders, the average hourly difference (CRDS - NDIR) of the two systems is -0.03 ppm ± 0.25 ppm. Although the difference of the two datasets is in line with the compatibility goal of ±0.1 ppm of the World Meteorological Organization (WMO), the standard deviation is still too high. A significant part of this uncertainty originates from the necessity to switch the KUP system frequently (every 12 min) for 6 min from ambient air to a working gas in order to correct short-term variations of the O2 measurement system. Allowing additionally for signal stabilization after switching the sample, an effective data coverage of only 1/6 for the KUP system is achieved while the Empa system has a nearly complete data coverage. Additionally, different internal volumes and flow rates between the two systems may affect observed differences.

  19. Comparison of continuous in situ CO2 observations at Jungfraujoch using two different measurement techniques

    NASA Astrophysics Data System (ADS)

    Schibig, M. F.; Steinbacher, M.; Buchmann, B.; van der Laan-Luijkx, I. T.; van der Laan, S.; Ranjan, S.; Leuenberger, M. C.

    2015-01-01

    Since 2004, atmospheric carbon dioxide (CO2) is being measured at the High Altitude Research Station Jungfraujoch by the division of Climate and Environmental Physics at the University of Bern (KUP) using a nondispersive infrared gas analyzer (NDIR) in combination with a paramagnetic O2 analyzer. In January 2010, CO2 measurements based on cavity ring-down spectroscopy (CRDS) as part of the Swiss National Air Pollution Monitoring Network were added by the Swiss Federal Laboratories for Materials Science and Technology (Empa). To ensure a smooth transition - a prerequisite when merging two data sets, e.g., for trend determinations - the two measurement systems run in parallel for several years. Such a long-term intercomparison also allows the identification of potential offsets between the two data sets and the collection of information about the compatibility of the two systems on different time scales. A good agreement of the seasonality, short-term variations and, to a lesser extent mainly due to the short common period, trend calculations is observed. However, the comparison reveals some issues related to the stability of the calibration gases of the KUP system and their assigned CO2 mole fraction. It is possible to adapt an improved calibration strategy based on standard gas determinations, which leads to better agreement between the two data sets. By excluding periods with technical problems and bad calibration gas cylinders, the average hourly difference (CRDS - NDIR) of the two systems is -0.03 ppm ± 0.25 ppm. Although the difference of the two data sets is in line with the compatibility goal of ±0.1 ppm of the World Meteorological Organization (WMO), the standard deviation is still too high. A significant part of this uncertainty originates from the necessity to switch the KUP system frequently (every 12 min) for 6 min from ambient air to a working gas in order to correct short-term variations of the O2 measurement system. Allowing additional time for signal stabilization after switching the sample, an effective data coverage of only one-sixth for the KUP system is achieved while the Empa system has a nearly complete data coverage. Additionally, different internal volumes and flow rates may affect observed differences.

  20. Applying an Inverse Model to Estimate Ammonia Emissions at Cattle Feedlots Using Three Different Observation-Based Approaches

    NASA Astrophysics Data System (ADS)

    Shonkwiler, K. B.; Ham, J. M.; Nash, C.

    2014-12-01

    Accurately quantifying emissions of ammonia (NH3) from confined animal feeding operations (CAFOs) is vital not only to the livestock industry, but essential to understanding nitrogen cycling along the Front Range of Colorado, USA, where intensive agriculture, urban sprawl, and pristine ecosystems (e.g., Rocky Mtn Nat'l Park) lie within 100-km of each other. Most observation-based techniques for estimating NH3 emissions can be expensive and highly technical. Many methods rely on concentration observations on location, which implicitly depends on weather conditions. A system for sampling NH3 using on-site weather data was developed to allow remote measurement of NH3 in a simple, cost-effective way. These systems use passive diffusive cartridges (Radiello, Sigma-Aldrich) that provide time-averaged concentrations representative of a typical two-week deployment. Cartridge exposure is robotically managed so they are only visible when winds are 1.4 m/s or greater from the direction of the CAFO. These concentration data can be coupled with stability parameters (measured on-site) in a simple inverse model to estimate emissions (FIDES, UMR Environnement et Grandes Cultures). Few studies have directly compared emissions estimates of NH3 using concentration data obtained from multiple measurement systems at different temporal and spatial scales. Therefore, in the summer and autumn of 2014, several conditional sampler systems were deployed at a 25,000-head cattle feedlot concomitant with an open-path infrared laser (GasFinder2, Boreal Laser Inc.) and a Cavity Ring Down Spectrometer (CRDS) (G1103, Picarro Inc.) which each measured instantaneous NH3 concentrations. This study will test the sampler technology by first comparing concentration data from the three different methods. In livestock research, it is common to estimate NH3 emissions by using such instantaneous data in a backward Lagrangian stochastic (bLs) model (WindTrax, Thunder Beach Sci.) Considering this, NH3 fluxes from the inverse model (FIDES) using all three datasets will be compared to emissions from the bLS model (WindTrax) using only high speed data (laser; CRDS). Results may lend further validity to the conditional sampler approach for more easily and accurately monitoring NH3 fluxes from CAFOs and other strong areal sources.

  1. Soma of the Rigveda and an attempt to identify it.

    PubMed

    Mahdihassan, S; Mehdi, F S

    1989-01-01

    Ephedra juice is used as the drink of longevity given even to the new born. This is an Aryan custom mentioned in Rigveda and followed even by the Romans. To trace the history of this custom would lead to identifying Soma = Ephedra. The original species of Ephedra or Soma proper would be Ephedra sinica, the Chinese plant. It is the one species with yellow stalks. This has been illustrated so that it confirms Rigveda speaking of Soma as "golden yellow." The name Soma is also a loan word from Chinese meaning "fire-yellow fibers of hemp." The plant Soma is described as "thousand boughs" and photographic evidence has been offered in support. Each stalk is rod-like resembling an arrow as Rigveda speaks of it. An illustration has been offered to show the plant with stalks which are straight and rod-like, comparable with an arrow.

  2. Damage Detection Sensor System for Aerospace and Multiple Applications

    NASA Technical Reports Server (NTRS)

    Williams, M.; Lewis, M.; Gibson, T.; Medelius, P.; Lane, J.

    2017-01-01

    The damage detection sensory system is an intelligent damage detection ‘skin’ that can be embedded into rigid or flexible structures, providing a lightweight capability for in-situ health monitoring for applications such as spacecraft, expandable or inflatable structures, extravehicular activities (EVA) suits, smart wearables, and other applications where diagnostic impact damage monitoring might be critical. The sensor systems can be customized for detecting location, damage size, and depth, with velocity options and can be designed for particular environments for monitoring of impact or physical damage to a structure. The operation of the sensor detection system is currently based on the use of parallel conductive traces placed on a firm or flexible surface. Several detection layers can be implemented, where alternate layers are arranged in orthogonal direction with respect to the adjacent layers allowing for location and depth calculations. Increased flexibility of the damage detection sensor system designs will also be introduced.

  3. Improving Atomic Force Microscopy Imaging by a Direct Inverse Asymmetric PI Hysteresis Model

    PubMed Central

    Wang, Dong; Yu, Peng; Wang, Feifei; Chan, Ho-Yin; Zhou, Lei; Dong, Zaili; Liu, Lianqing; Li, Wen Jung

    2015-01-01

    A modified Prandtl–Ishlinskii (PI) model, referred to as a direct inverse asymmetric PI (DIAPI) model in this paper, was implemented to reduce the displacement error between a predicted model and the actual trajectory of a piezoelectric actuator which is commonly found in AFM systems. Due to the nonlinearity of the piezoelectric actuator, the standard symmetric PI model cannot precisely describe the asymmetric motion of the actuator. In order to improve the accuracy of AFM scans, two series of slope parameters were introduced in the PI model to describe both the voltage-increase-loop (trace) and voltage-decrease-loop (retrace). A feedforward controller based on the DIAPI model was implemented to compensate hysteresis. Performance of the DIAPI model and the feedforward controller were validated by scanning micro-lenses and standard silicon grating using a custom-built AFM. PMID:25654719

  4. A new type industrial total station based on target automatic collimation

    NASA Astrophysics Data System (ADS)

    Lao, Dabao; Zhou, Weihu; Ji, Rongyi; Dong, Dengfeng; Xiong, Zhi; Wei, Jiang

    2018-01-01

    In the case of industrial field measurement, the present measuring instruments work with manual operation and collimation, which give rise to low efficiency for field measurement. In order to solve the problem, a new type industrial total station is presented in this paper. The new instrument can identify and trace cooperative target automatically, in the mean time, coordinate of the target is measured in real time. For realizing the system, key technology including high precision absolutely distance measurement, small high accuracy angle measurement, target automatic collimation with vision, and quick precise controlling should be worked out. After customized system assemblage and adjustment, the new type industrial total station will be established. As the experiments demonstrated, the coordinate accuracy of the instrument is under 15ppm in the distance of 60m, which proved that the measuring system is feasible. The result showed that the total station can satisfy most industrial field measurement requirements.

  5. 47 CFR 64.2010 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... authenticate a customer prior to disclosing CPNI based on customer-initiated telephone contact, online account... customer. (c) Online access to CPNI. A telecommunications carrier must authenticate a customer without the... customer online access to CPNI related to a telecommunications service account. Once authenticated, the...

  6. 47 CFR 64.2010 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authenticate a customer prior to disclosing CPNI based on customer-initiated telephone contact, online account... customer. (c) Online access to CPNI. A telecommunications carrier must authenticate a customer without the... customer online access to CPNI related to a telecommunications service account. Once authenticated, the...

  7. 47 CFR 64.2010 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... authenticate a customer prior to disclosing CPNI based on customer-initiated telephone contact, online account... customer. (c) Online access to CPNI. A telecommunications carrier must authenticate a customer without the... customer online access to CPNI related to a telecommunications service account. Once authenticated, the...

  8. The GIS map coloring support decision-making system based on case-based reasoning and simulated annealing algorithm

    NASA Astrophysics Data System (ADS)

    Deng, Shuang; Xiang, Wenting; Tian, Yangge

    2009-10-01

    Map coloring is a hard task even to the experienced map experts. In the GIS project, usually need to color map according to the customer, which make the work more complex. With the development of GIS, more and more programmers join the project team, which lack the training of cartology, their coloring map are harder to meet the requirements of customer. From the experience, customers with similar background usually have similar tastes for coloring map. So, we developed a GIS color scheme decision-making system which can select color schemes of similar customers from case base for customers to select and adjust. The system is a BS/CS mixed system, the client side use JSP and make it possible for the system developers to go on remote calling of the colors scheme cases in the database server and communicate with customers. Different with general case-based reasoning, even the customers are very similar, their selection may have difference, it is hard to provide a "best" option. So, we select the Simulated Annealing Algorithm (SAA) to arrange the emergence order of different color schemes. Customers can also dynamically adjust certain features colors based on existing case. The result shows that the system can facilitate the communication between the designers and the customers and improve the quality and efficiency of coloring map.

  9. Alternative Fuels Data Center: Going Beyond Gas: Nissan Brings Car Charging

    Science.gov Websites

    Charging to Indianapolis Convenience Store Chain " We've seen a steady increase in our customer base that alleviating customer concerns needed to be a top priority. "PEV sales hinge on customers steady increase in our customer base since installing the equipment a couple of years ago." Although

  10. 19 CFR 152.108 - Unacceptable bases of appraisement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 2 2013-04-01 2013-04-01 false Unacceptable bases of appraisement. 152.108 Section 152.108 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Merchandise § 152.108 Unacceptable bases of appraisement. For the purposes of this subpart, imported...

  11. 19 CFR 152.108 - Unacceptable bases of appraisement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 2 2011-04-01 2011-04-01 false Unacceptable bases of appraisement. 152.108 Section 152.108 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Merchandise § 152.108 Unacceptable bases of appraisement. For the purposes of this subpart, imported...

  12. 19 CFR 152.108 - Unacceptable bases of appraisement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 2 2012-04-01 2012-04-01 false Unacceptable bases of appraisement. 152.108 Section 152.108 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Merchandise § 152.108 Unacceptable bases of appraisement. For the purposes of this subpart, imported...

  13. 19 CFR 152.108 - Unacceptable bases of appraisement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Unacceptable bases of appraisement. 152.108 Section 152.108 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Merchandise § 152.108 Unacceptable bases of appraisement. For the purposes of this subpart, imported...

  14. Engineering Design and Testing of a Novel High-Resolution Trace-Metal Clean Sampler for Profiling and Long-term Deployment Applications

    NASA Astrophysics Data System (ADS)

    Mueller, A. V.; Crusius, J.; Carlson, K.; Chapin, T. P.

    2016-02-01

    Design, assembly, and testing of a novel in-situ sampler for automated high-frequency trace-metal clean sampling at ocean moorings was undertaken with the goal of improving marine data density for iron (and other metals) by up to a factor of ten relative to existing samplers. Target characteristics are: modular, flexible use (profiling, static moorings, AUV-deployed), high capacity (100-200 samples), low power, low cost ($3k per 100-samples), ability to collect filtered + unfiltered samples, and simple assembly. Smaller sample volumes (10mL) are enabled by recent innovations in analysis techniques, while use of off-the-shelf components enables lower cost and faster development time, although attention must be taken to verify trace-metal cleanliness of materials in commercial products. Standard polypropylene syringes (tips with lock fittings) are adapted as sample chambers through fabrication of a dual (viton) o-ring replacement plunger to prevent barrel contamination between acid washing and sample collection. Syringes are mounted along a (pumped) sampling channel machined into a modular custom-designed 7.5in. HDPE ring; successive rings stack, fitted around the central 3 in. PVC pressure housing containing the pump, batteries, and temperature and pressure sensors. Optional filtering (0.45um) is easily added at the inlet to the pumped sampling line. Syringes, pre-filled with acid for sample preservation, are held "closed" using plastic zipties connected to the plunger pull; individual syringes are selected for filling by breaking a 0.003in. wire (e.g., stainless steel, gold-plated tungsten/rhenium) with a pulse of current or by melting the ziptie loop using a nichrome wire. Multiplexed addressing minimizes required microcontroller output pins and wires between the free-flooded collection chamber and the pressure housing. A novel, custom rotating inlet mounting scheme ensures that the pump tubing inlet remains positioned approximately 1m upstream of the sampler.

  15. Optimized square Fresnel zone plates for microoptics applications

    NASA Astrophysics Data System (ADS)

    Rico-García, José María; Salgado-Remacha, Francisco Javier; Sanchez-Brea, Luis Miguel; Alda, Javier

    2009-06-01

    Polygonal Fresnel zone plates with a low number of sides have deserved attention in micro and nanoptics, because they can be straightforwardly integrated in photonic devices, and, at the same time, they represent a balance between the high-focusing performance of a circular zone plate and the easiness of fabrication at micro and nano-scales of polygons. Among them, the most representative family are Square Fresnel Zone Plates (SFZP). In this work, we propose two different customized designs of SFZP for optical wavelengths. Both designs are based on the optimization of a SFZP to perform as close as possible as a usual Fresnel Zone Plate. In the first case, the criterion followed to compute it is the minimization of the difference between the area covered by the angular sector of the zone of the corresponding circular plate and the one covered by the polygon traced on the former. Such a requirement leads to a customized polygon-like Fresnel zone. The simplest one is a square zone with a pattern of phases repeating each five zones. On the other hand, an alternative SFZP can be designed guided by the same criterion but with a new restriction. In this case, the distance between the borders of different zones remains unaltered. A comparison between the two lenses is carried out. The irradiance at focus is computed for both and suitable merit figures are defined to account for the difference between them.

  16. Omnidirectional Underwater Camera Design and Calibration

    PubMed Central

    Bosch, Josep; Gracias, Nuno; Ridao, Pere; Ribas, David

    2015-01-01

    This paper presents the development of an underwater omnidirectional multi-camera system (OMS) based on a commercially available six-camera system, originally designed for land applications. A full calibration method is presented for the estimation of both the intrinsic and extrinsic parameters, which is able to cope with wide-angle lenses and non-overlapping cameras simultaneously. This method is valid for any OMS in both land or water applications. For underwater use, a customized housing is required, which often leads to strong image distortion due to refraction among the different media. This phenomena makes the basic pinhole camera model invalid for underwater cameras, especially when using wide-angle lenses, and requires the explicit modeling of the individual optical rays. To address this problem, a ray tracing approach has been adopted to create a field-of-view (FOV) simulator for underwater cameras. The simulator allows for the testing of different housing geometries and optics for the cameras to ensure a complete hemisphere coverage in underwater operation. This paper describes the design and testing of a compact custom housing for a commercial off-the-shelf OMS camera (Ladybug 3) and presents the first results of its use. A proposed three-stage calibration process allows for the estimation of all of the relevant camera parameters. Experimental results are presented, which illustrate the performance of the calibration method and validate the approach. PMID:25774707

  17. Cavity-locked ring down spectroscopy

    DOEpatents

    Zare, Richard N.; Paldus, Barbara A.; Harb, Charles C.; Spence, Thomas

    2000-01-01

    Distinct locking and sampling light beams are used in a cavity ring-down spectroscopy (CRDS) system to perform multiple ring-down measurements while the laser and ring-down cavity are continuously locked. The sampling and locking light beams have different frequencies, to ensure that the sampling and locking light are decoupled within the cavity. Preferably, the ring-down cavity is ring-shaped, the sampling light is s-polarized, and the locking light is p-polarized. Transmitted sampling light is used for ring-down measurements, while reflected locking light is used for locking in a Pound-Drever scheme.

  18. Optical fibre cavity ring down measurement of refractive index with a microchannel drilled by femtosecond laser

    NASA Astrophysics Data System (ADS)

    Zhou, Kaiming; Webb, David; Mou, Chengbo; Farries, Mark; Hayes, Neil; Bennion, Ian

    2009-10-01

    μA microchannel was inscribed in the fibre of a ring cavity which was constructed from two 0.1%:99.9% couplers and a 10m fibre loop. Cavity ring down spectroscopy (CRDS) was used to measure the refractive index (RI) of gels infused into the microchannel with high resolution. The ring down time discloses a nonlinear increase with respect to the RI of the gel and sensitivity up to 300μs/RI unit (RIU) and resolution of 5×10-4 were obtained.

  19. Do Professors Have Customer-Based Brand Equity?

    ERIC Educational Resources Information Center

    Jillapalli, Ravi K.; Jillapalli, Regina

    2014-01-01

    This research endeavors to understand whether certain professors have customer-based brand equity (CBBE) in the minds of students. Consequently, the purpose of this study is to conceptualize, develop, and empirically test a model of customer-based professor brand equity. Survey data gathered from 465 undergraduate business students were used to…

  20. High-output LED-based light engine for profile lighting fixtures with high color uniformity using freeform reflectors.

    PubMed

    Gadegaard, Jesper; Jensen, Thøger Kari; Jørgensen, Dennis Thykjær; Kristensen, Peter Kjær; Søndergaard, Thomas; Pedersen, Thomas Garm; Pedersen, Kjeld

    2016-02-20

    In the stage lighting and entertainment market, light engines (LEs) for lighting fixtures are often based on high-intensity discharge (HID) bulbs. Switching to LED-based light engines gives possibilities for fast switching, additive color mixing, a longer lifetime, and potentially, more energy-efficient systems. The lumen output of a single LED is still not sufficient to replace an HID source in high-output profile fixtures, but combining multiple LEDs can create an LE with a similar output, but with added complexity. This paper presents the results of modeling and testing such a light engine. Custom ray-tracing software was used to design a high-output red, green and blue LED-based light engine with twelve CBT-90 LEDs using a dual-reflector principle. The simulated optical system efficiency was 0.626 with a perfect (R=1) reflector coating for light delivered on a target surface through the entire optical system. A profile lighting fixture prototype was created, and provided an output of 6744 lumen and an efficiency of 0.412. The lower efficiency was mainly due to a non-optimal reflector coating, and the optimized design is expected to reach a significantly higher efficiency.

  1. To Customize or Not to Customize? Exploring Science Teacher Customization in an Online Lesson Portal

    ERIC Educational Resources Information Center

    Littenberg-Tobias, Joshua; Beheshti, Elham; Staudt, Carolyn

    2016-01-01

    New technologies are increasingly giving science teachers the ability to access and customize science lessons. However, there is substantial debate in the literature about whether and under what conditions teacher customization benefit student learning. In this study, we examined teacher customization of inquiry-based science lessons from an…

  2. Loyalty-based management.

    PubMed

    Reichheld, F F

    1993-01-01

    Despite a flurry of activities aimed at serving customers better, few companies have systematically revamped their operations with customer loyalty in mind. Instead, most have adopted improvement programs ad hoc, and paybacks haven't materialized. Building a highly loyal customer base must be integral to a company's basic business strategy. Loyalty leaders like MBNA credit cards are successful because they have designed their entire business systems around customer loyalty--a self-reinforcing system in which the company delivers superior value consistently and reinvents cash flows to find and keep high-quality customers and employees. The economic benefits of high customer loyalty are measurable. When a company consistently delivers superior value and wins customer loyalty, market share and revenues go up, and the cost of acquiring new customers goes down. The better economics mean the company can pay workers better, which sets off a whole chain of events. Increased pay boosts employee moral and commitment; as employees stay longer, their productivity goes up and training costs fall; employees' overall job satisfaction, combined with their experience, helps them serve customers better; and customers are then more inclined to stay loyal to the company. Finally, as the best customers and employees become part of the loyalty-based system, competitors are left to survive with less desirable customers and less talented employees. To compete on loyalty, a company must understand the relationships between customer retention and the other parts of the business--and be able to quantify the linkages between loyalty and profits. It involves rethinking and aligning four important aspects of the business: customers, product/service offering, employees, and measurement systems.

  3. Store manager performance and satisfaction: effects on store employee performance and satisfaction, store customer satisfaction, and store customer spending growth.

    PubMed

    Netemeyer, Richard G; Maxham, James G; Lichtenstein, Donald R

    2010-05-01

    Based on emotional contagion theory and the value-profit chain literatures, the present study posits a number of hypotheses that show how managers in the small store, small number of employees retail context may affect store employees, customers, and potentially store performance. With data from 306 store managers, 1,615 store customer-contact employees, and 57,656 customers of a single retail chain, the authors examined relationships among store manager job satisfaction and job performance, store customer-contact employee job satisfaction and job performance, customer satisfaction with the retailer, and a customer-spending-based store performance metric (customer spending growth over a 2-year period). Via path analysis, several hypothesized direct and interaction relations among these constructs are supported. The results suggest implications for academic researchers and retail managers. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  4. CRDS of 17O enriched water between 5850 and 6671 cm-1: More than 1000 energy levels of H217O and HD17O newly determined

    NASA Astrophysics Data System (ADS)

    Mikhailenko, S. N.; Leshchishina, O.; Karlovets, E. V.; Mondelain, D.; Kassi, S.; Campargue, A.

    2016-07-01

    The room temperature absorption spectrum of water vapor highly enriched in 17O has been recorded by Cavity Ring Down Spectroscopy (CRDS) between 5850 and 6671 cm-1. Two series of recordings were performed with pressure values of 1.0 and 12.0 Torr. The investigated spectral region corresponds to the important 1.55 μm transparency window of the atmosphere where water absorption is very weak. The high sensitivity of the recordings (αmin 5×10-11 cm-1) allows detecting lines with intensity spanning six orders of magnitude (1.4×10-30-3.6×10-24 cm/molecule at room temperature). The experimental list includes more than 10,300 lines. The assignments of water lines were performed using known experimental energy levels as well as calculated line lists based on the results of Partridge and Schwenke. More than 8500 lines were assigned to 9619 transitions of six water isotopologues (H216O, H217O, H218O, HD16O, HD17O and HD18O). All but four transitions of the 16O and 18O isotopologues were assigned using known experimental energy levels. More than half of the assigned H217O and HD17O transitions correspond to new (or corrected) upper energy levels. About 1000 new H217O transitions associated with upper states of the second triad and of the first hexad were identified. Most of the newly assigned HD17O transitions belong to the ν1+ν3 and 2ν2+ν3 bands. The assigned transitions allowed to newly determine or correct 20 highly excited rotational levels of the vibrational ground state of this isotopologue. Overall 791 and 266 energy levels are newly determined for H217O and HD17O, respectively. A few additional levels were corrected compared to literature values. The obtained experimental results are compared to the spectroscopic parameters provided by the HITRAN database and to the empirical energy levels recommended by an IUPAC task group.

  5. Frequency-Agile Differential Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Reed, Zachary; Hodges, Joseph

    2015-06-01

    The ultimate precision of highly sensitive cavity-enhanced spectroscopic measurements is often limited by interferences (etalons) caused by weak coupled-cavity effects. Differential measurements of ring-down decay constants have previously been demonstrated to largely cancel these effects, but the measurement acquisition rates were relatively low [1,2]. We have previously demonstrated the use of frequency agile rapid scanning cavity ring-down spectroscopy (FARS-CRDS) for acquisition of absorption spectra [3]. Here, the method of rapidly scanned, frequency-agile differential cavity ring-down spectroscopy (FADS-CRDS) is presented for reducing the effect of these interferences and other shot-to-shot statistical variations in measured decay times. To this end, an electro-optic phase modulator (EOM) with a bandwidth of 20 GHz is driven by a microwave source, generating pairs of sidebands on the probe laser. The optical resonator acts as a highly selective optical filter to all laser frequencies except for one tunable sideband. This sideband may be stepped arbitrarily from mode-to-mode of the ring-down cavity, at a rate limited only by the cavity buildup/decay time. The ability to probe any cavity mode across the EOM bandwidth enables a variety of methods for generating differential spectra. The differential mode spacing may be changed, and the effect of this method on suppressing the various coupled-cavity interactions present in the system is discussed. Alternatively, each mode may also be differentially referenced to a single point, providing immunity to temporal variations in the base losses of the cavity while allowing for conventional spectral fitting approaches. Differential measurements of absorption are acquired at 3.3 kHz and a minimum detectable absorption coefficient of 5 x10-12 cm-1 in 1 s averaging time is achieved. 1. J. Courtois, K. Bielska, and J.T Hodges J. Opt. Soc. Am. B, 30, 1486-1495, 2013 2. H.F. Huang and K.K. Lehmann App. Optics 49, 1378-1387, 2010 3. G.-W. Truong, K.O. Douglass, S.E. Maxwell, R.D. van Zee, D.F. Plusquellic, J.T. Hodges, and D.A. Long Nature Photonics, 7, 532-534, 2013

  6. New Partnerships Help Utilities Break Down Solar Barriers | News | NREL

    Science.gov Websites

    local customers. Due to the small size of many member organizations and customer bases, some members face a challenge in accommodating customer requests to interconnect customer-sited solar photovoltaic supported the growth of customer-sited solar PV installations in recent years. In response to customer

  7. 48 CFR 1812.7000 - Prohibition on guaranteed customer bases for new commercial space hardware or services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... customer bases for new commercial space hardware or services. 1812.7000 Section 1812.7000 Federal... PLANNING ACQUISITION OF COMMERCIAL ITEMS Commercial Space Hardware or Services 1812.7000 Prohibition on guaranteed customer bases for new commercial space hardware or services. Public Law 102-139, title III...

  8. 75 FR 60409 - Diamond Sawblades and Parts Thereof From the People's Republic of China: Initiation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-30

    ... facilities; (2) supplier relationships; (3) management; and (4) customer base.\\6\\ \\6\\ See Letter from Hebei...; and (4) customer base.\\8\\ Although no single factor will necessarily provide a dispositive indication... management, suppliers, customer base, and production facilities that the Department considers in its...

  9. Customized versus population-based growth curves: prediction of low body fat percent at term corrected gestational age following preterm birth.

    PubMed

    Law, Tameeka L; Katikaneni, Lakshmi D; Taylor, Sarah N; Korte, Jeffrey E; Ebeling, Myla D; Wagner, Carol L; Newman, Roger B

    2012-07-01

    Compare customized versus population-based growth curves for identification of small-for-gestational-age (SGA) and body fat percent (BF%) among preterm infants. Prospective cohort study of 204 preterm infants classified as SGA or appropriate-for-gestational-age (AGA) by population-based and customized growth curves. BF% was determined by air-displacement plethysmography. Differences between groups were compared using bivariable and multivariable linear and logistic regression analyses. Customized curves reclassified 30% of the preterm infants as SGA. SGA infants identified by customized method only had significantly lower BF% (13.8 ± 6.0) than the AGA (16.2 ± 6.3, p = 0.02) infants and similar to the SGA infants classified by both methods (14.6 ± 6.7, p = 0.51). Customized growth curves were a significant predictor of BF% (p = 0.02), whereas population-based growth curves were not a significant independent predictor of BF% (p = 0.50) at term corrected gestational age. Customized growth potential improves the differentiation of SGA infants and low BF% compared with a standard population-based growth curve among a cohort of preterm infants.

  10. Profit-Based Model Selection for Customer Retention Using Individual Customer Lifetime Values.

    PubMed

    Óskarsdóttir, María; Baesens, Bart; Vanthienen, Jan

    2018-03-01

    The goal of customer retention campaigns, by design, is to add value and enhance the operational efficiency of businesses. For organizations that strive to retain their customers in saturated, and sometimes fast moving, markets such as the telecommunication and banking industries, implementing customer churn prediction models that perform well and in accordance with the business goals is vital. The expected maximum profit (EMP) measure is tailored toward this problem by taking into account the costs and benefits of a retention campaign and estimating its worth for the organization. Unfortunately, the measure assumes fixed and equal customer lifetime value (CLV) for all customers, which has been shown to not correspond well with reality. In this article, we extend the EMP measure to take into account the variability in the lifetime values of customers, thereby basing it on individual characteristics. We demonstrate how to incorporate the heterogeneity of CLVs when CLVs are known, when their prior distribution is known, and when neither is known. By taking into account individual CLVs, our proposed approach of measuring model performance gives novel insights when deciding on a customer retention campaign. The method is dependent on the characteristics of the customer base as is compliant with modern business analytics and accommodates the data-driven culture that has manifested itself within organizations.

  11. Assessment of two e-learning methods teaching undergraduate students cephalometry in orthodontics.

    PubMed

    Ludwig, B; Bister, D; Schott, T C; Lisson, J A; Hourfar, J

    2016-02-01

    Cephalometry is important for orthodontic diagnosis and treatment planning and is part of the core curriculum for training dentists. Training involves identifying anatomical landmarks. The aim of this investigation was to assess whether e-learning improves learning efficiency; a programme specifically designed for this purpose was compared to commercially available software. Thirty undergraduate students underwent traditional training of cephalometry consisting of lectures and tutorials. Tracing skills were tested immediately afterwards (T0). The students were then randomly allocated to three groups: 10 students served as control (CF); they were asked to improve their skills using the material provided so far. Ten students were given a program specifically designed for this study that was based on a power point presentation (PPT). The last group was given a commercially available program that included teaching elements (SW). The groups were tested at the end the six week training (T1). The test consisted of tracing 30 points on two radiographs and a point score improvement was calculated. The students were interviewed after the second test. Both e-learning groups improved more than the traditional group. Improvement scores were four for CF; 8.6 for PPT and 2.8 for SW. For PPT all participants improved and the student feedback was the best compared to the other groups. For the other groups some candidates worsened. Blended learning produced better learning outcomes compared to using a traditional teaching method alone. The easy to use Power Point based custom software produced better results than the commercially available software. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Forensic drug intelligence and the rise of cryptomarkets. Part II: Combination of data from the physical and virtual markets.

    PubMed

    Morelato, Marie; Broséus, Julian; De Grazia, Adrian; Tahtouh, Mark; Esseiva, Pierre; Roux, Claude

    2018-07-01

    Technology provides new ways to access customers and suppliers while enhancing the security of off-line criminal activity. Since the first cryptomarket, Silk Road, in 2011, cryptomarkets have transformed the traditional drug sale by facilitating the creation of a global network of vendors and buyers. Due to the fragmented nature of traces that result from illegal activities, combining the results of concurrent processes based on traces of different nature should provide supplementary benefit to understand the drug market. This article compares the data of the Australian virtual market (in particular data extracted from cryptomarkets) to the data related to traditional market descriptors, namely national seizures and arrests, prevalence data, shipping countries of seized post shipments as well as outcomes of specific surveys targeting users' behaviour online. Results revealed the domestic nature of the online illicit drug trade in Australia which is dominated by amphetamine-type substances (ATS), in particular methylamphetamine and cannabis. These illicit drugs were also the most seized drugs on the physical market. This article shows that the combination of different information offers a broader perspective of the illicit drug market in Australia and thus provides stronger arguments for policy makers. It also highlights the links between the virtual and physical markets. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Mobile Instruments Measure Atmospheric Pollutants

    NASA Technical Reports Server (NTRS)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  14. Poster - Thur Eve - 11: A realistic respiratory trace generator and its application to respiratory management techniques.

    PubMed

    Quirk, S; Becker, N; Smith, W L

    2012-07-01

    Respiratory motion complicates radiotherapy treatment of thoracic and abdominal tumours. Simplified respiratory motions such as sinusoidal and single patient traces are often used to determine the impact of motion on respiratory management techniques in radiotherapy. Such simplifications only accurately model a small portion of patients, as most patients exhibit variability and irregularity beyond these models. We have preformed a comprehensive analysis of respiratory motion and developed a software tool that allows for explicit inclusion of variability. We utilize our realistic respiratory generator to customize respiratory traces to test the robustness of the estimate of internal gross target volumes (IGTV) by 4DCT and CBCT. We confirmed that good agreement is found between 4DCT and CBCT for regular breathing motion. When amplitude variability was introduced the accuracy of the estimate slightly, but the absolute differences were still < 3 mm for both modalities. Poor agreement was shown with the addition of baseline drifts. Both modalities were found to underestimate the IGTV by as much as 30% for 4DCT and 25% for CBCT. Both large and small drifts deteriorated the estimate accuracy. The respiratory trace generator was advantageous for examining the difference between 4DCT and CBCT IGTV estimation under variable motions. It provided useful implementation abilities to test specific attributes of respiratory motion and detected issues that were not seen with the regular motion studies. This is just one example of how the respiratory trace generator can be utilized to test applications of respiratory management techniques. © 2012 American Association of Physicists in Medicine.

  15. THE BENEFITS OF CUSTOMIZED DNA DIRECTED NUTRITION TO BALANCE THE BRAIN REWARD CIRCUITRY AND REDUCE ADDICTIVE BEHAVIORS

    PubMed Central

    Blum, Kenneth; Downs, B.W.; Dushaj, Kristina; Li, Mona; Braverman, Eric R.; Fried, Lyle; Waite, Roger; Demotrovics, Zsolt; Badgaiyan, Rajendra D.

    2016-01-01

    DNA Customization of nutraceutical products is here. In the truest sense, “Gene Guided Precision Nutrition™” and KB220 variants (a complex mixture of amino–acids, trace metals, and herbals) are the pioneers and standard-bearers for a state of the art DNA customization. Findings by both, Kenneth Blum, Ph.D. and Ernest Noble, Ph.D. concerning the role of genes in shaping cravings and pleasure- seeking, opened the doors to comprehension of how genetics control our actions and effect our mental and physical health. Moreover, technology that is related to KB220 variants in order to reduce or eradicate excessive cravings by influencing gene expression is a cornerstone in the pioneering of the practical applications of nutrigenomics. Continuing discoveries have been an important catalyst for the evolution, expansion, and scientific recognition of the significance of nutrigenomics and its remarkable contributions to human health. Neuro-Nutrigenomics is now a very important field of scientific investigation that offers great promise to improving the human condition. In the forefront is the development of the Genetic Addiction Risk Score (GARS™), which unlike 23andMe, has predictive value for the severity of drug and alcohol abuse as well as other non-substance related addictive behaviors. While customization of neuronutrients has not yet been commercialized, there is emerging evidence that in the future, the concept will be developed and could have a significant impact in addiction medicine. PMID:28066828

  16. THE BENEFITS OF CUSTOMIZED DNA DIRECTED NUTRITION TO BALANCE THE BRAIN REWARD CIRCUITRY AND REDUCE ADDICTIVE BEHAVIORS.

    PubMed

    Blum, Kenneth; Downs, B W; Dushaj, Kristina; Li, Mona; Braverman, Eric R; Fried, Lyle; Waite, Roger; Demotrovics, Zsolt; Badgaiyan, Rajendra D

    2016-01-01

    DNA Customization of nutraceutical products is here. In the truest sense, "Gene Guided Precision Nutrition ™ " and KB220 variants (a complex mixture of amino-acids, trace metals, and herbals) are the pioneers and standard-bearers for a state of the art DNA customization. Findings by both, Kenneth Blum, Ph.D. and Ernest Noble, Ph.D. concerning the role of genes in shaping cravings and pleasure- seeking, opened the doors to comprehension of how genetics control our actions and effect our mental and physical health. Moreover, technology that is related to KB220 variants in order to reduce or eradicate excessive cravings by influencing gene expression is a cornerstone in the pioneering of the practical applications of nutrigenomics. Continuing discoveries have been an important catalyst for the evolution, expansion, and scientific recognition of the significance of nutrigenomics and its remarkable contributions to human health. Neuro-Nutrigenomics is now a very important field of scientific investigation that offers great promise to improving the human condition. In the forefront is the development of the Genetic Addiction Risk Score (GARS ™ ), which unlike 23andMe, has predictive value for the severity of drug and alcohol abuse as well as other non-substance related addictive behaviors. While customization of neuronutrients has not yet been commercialized, there is emerging evidence that in the future, the concept will be developed and could have a significant impact in addiction medicine.

  17. Quality evaluation in health care services based on customer-provider relationships.

    PubMed

    Eiriz, Vasco; Figueiredo, José António

    2005-01-01

    To develop a framework for evaluating the quality of Portuguese health care organisations based on the relationship between customers and providers, to define key variables related to the quality of health care services based on a review of the available literature, and to establish a conceptual framework in order to test the framework and variables empirically. Systematic review of the literature. Health care services quality should not be evaluated exclusively by customers. Given the complexity, ambiguity and heterogeneity of health care services, the authors develop a framework for health care evaluation based on the relationship between customers (patients, their relatives and citizens) and providers (managers, doctors, other technical staff and non-technical staff), and considering four quality items (customer service orientation, financial performance, logistical functionality and level of staff competence). This article identifies important changes in the Portuguese health care industry, such as the ownership of health care providers. At the same time, customers are changing their attitudes towards health care, becoming much more concerned and demanding of health services. These changes are forcing Portuguese private and public health care organisations to develop more marketing-oriented services. This article recognises the importance of quality evaluation of health care services as a means of increasing customer satisfaction and organisational efficiency, and develops a framework for health care evaluation based on the relationship between customers and providers.

  18. Global alliance against chronic respiratory diseases in Italy (GARD-Italy): strategy and activities.

    PubMed

    Laurendi, Giovanna; Mele, Sonia; Centanni, Stefano; Donner, Claudio F; Falcone, Franco; Frateiacci, Sandra; Lazzeri, Marta; Mangiacavallo, Antonino; Indinnimeo, Luciana; Viegi, Giovanni; Pisanti, Paola; Filippetti, Giuseppe

    2012-01-01

    The steady increase in incidence of chronic respiratory disease (CRD) now constitutes a serious public health problem. CRDs are often underdiagnosed and many patients are not diagnosed until the CRD is too severe to prevent normal daily activities. The prevention of CRDs and reducing their social and individual impacts means modifying environmental and social factors and improving diagnosis and treatment. Prevention of risk factors (tobacco smoke, allergens, occupational agents, indoor/outdoor air pollution) will significantly impact on morbidity and mortality. The Italian Ministry of Health (MoH) has made respiratory disease prevention a top priority and is implementing a comprehensive strategy with policies against tobacco smoking, indoor/outdoor pollution, obesity, and communicable diseases. Presently these actions are not well coordinated. The Global Alliance against Chronic Respiratory Diseases (GARD), set up by the World Health Organization, envisages national bodies; the GARD initiative in Italy, launched 11/6/2009, represents a great opportunity for the MoH. Its main objective is to promote the development of a coordinated CRD program in Italy. Effective prevention implies setting up a health policy with the support of healthcare professionals and citizen associations at national, regional, and district levels. What is required is a true inter-institutional synergy: respiratory diseases prevention cannot and should not be the responsibility of doctors alone, but must involve politicians/policymakers, as well as the media, local institutions, and schools, etc. GARD could be a significant experience and a great opportunity for Italy to share the GARD vision of a world where all people can breathe freely. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. High Pressure Oxygen A-Band Spectra

    NASA Astrophysics Data System (ADS)

    Drouin, Brian; Sung, Keeyoon; Yu, Shanshan; Lunny, Elizabeth M.; Bui, Thinh Quoc; Okumura, Mitchio; Rupasinghe, Priyanka; Bray, Caitlin; Long, David A.; Hodges, Joseph; Robichaud, David; Benner, D. Chris; Devi, V. Malathy; Hoo, Jiajun

    2015-06-01

    Composition measurements from remote sensing platforms require knowledge of air mass to better than the desired precision of the composition. Oxygen spectra allow determination of air mass since the mixing ratio of oxygen is fixed. The OCO-2 mission is currently retrieving carbon dioxide concentration using the oxygen A-band for air mass normalization. The 0.25% accuracy desired for the carbon dioxide concentration has pushed the state-of-the-art for oxygen spectroscopy. To produce atmospheric pressure A-band cross-sections with this accuracy requires a sophisticated line-shape model (Galatry or Speed-Dependent) with line mixing (LM) and collision induced absorption (CIA). Models of each of these phenomena exist, but an integrated self-consistent model must be developed to ensure accuracy. This presentation will describe the ongoing effort to parameterize these phenomena on a representative data set created from complementary experimental techniques. The techniques include Fourier transform spectroscopy (FTS), photo-acoustic spectroscopy (PAS) and cavity ring-down spectroscopy (CRDS). CRDS data allow long-pathlength measurements with absolute intensities, providing lineshape information as well as LM and CIA, however the subtleties of the lineshape are diminished in the saturated line-centers. Conversely, the short paths and large dynamic range of the PAS data allow the full lineshape to be discerned, but with an arbitrary intensity axis. Finally, the FTS data provides intermediate paths and consistency across a broad pressure range. These spectra are all modeled with the Labfit software using first the spectral line database HITRAN, and then model values are adjusted and fitted for better agreement with the data.

  20. UV-Visible Spectra of PAHs and Derivatives Seeded in Supersonic Jet. Astrophysical Implications

    NASA Astrophysics Data System (ADS)

    Salma, Bejaoui; Salama, Farid

    2018-06-01

    Laboratory absorption spectra of Polycyclic Aromatic Hydrocarbons (PAHs) and PAH derivatives measured under astrophysical relevant conditions are crucial to test the PAHs-DIBs hypothesis as well as the PAH model for the IR emission bands. Our dedicated experimental setup on the COsmic SImulation Chamber (COSmIC) provides an excellent platform to study neutral and ionized PAHs under the low temperature and pressure conditions that are representative of interstellar environments [1]. In this work, we study the effect of the substitution of CH bond(s) by a nitrogen atom(s) on the electronic spectra of phenanthrene. The electronic transitions associated with the lower excited states of neutral phenanthrene (C14H10) and phenanthridine (C13H9N) are measured in gas phase in the 315-345 nm region. Molecules are seeded in a supersonic expansion of argon gas and the absorption spectra are measured using the Cavity Ring Down Spectroscopy (CRDS) technique. Additional measurements of the absorption spectra of phenanthrene, phenantridine and 1,10-phenanthroline (C12H8N2) isolated in 10 K argon matrices are also performed. The comparison between the CRDS spectra with the absorption of the matrix-isolated molecules highlight the matrix-induced perturbations in band position, profiles and broadening and illustrates the need of gas phase measurements for more accurate comparisons with astronomical spectra.[1] Salama, F., Galazutdinov, G., Krelowski, et al. ApJ 728, 154[FS1] (2011).[2] A. Tielens, ApJ 526 Pt 1265–273 (2008),Acknowledgements: This research is supported by the APRA Program of NASA SMD

  1. Structural Basis for Carbohydrate Recognition and Anti-inflammatory Modulation by Gastrointestinal Nematode Parasite Toxascaris leonina Galectin.

    PubMed

    Hwang, Eun Young; Jeong, Mi Suk; Park, Sang Kyun; Ha, Sung Chul; Yu, Hak Sun; Jang, Se Bok

    2016-12-02

    Toxascaris leonina galectin (Tl-gal) is a galectin-9 homologue protein isolated from an adult worm of the canine gastrointestinal nematode parasite, and Tl-gal-vaccinated challenge can inhibit inflammation in inflammatory bowel disease-induced mice. We determined the first X-ray structures of full-length Tl-gal complexes with carbohydrates (lactose, N-acetyllactosamine, lacto-N-tetraose, sialyllactose, and glucose). Bonds were formed on concave surfaces of both carbohydrate recognition domains (CRDs) in Tl-gal. All binding sites were found in the HXXXR and WGXEER motifs. Charged Arg 61 /Arg 196 and Glu 80 /Glu 215 on the conserved motif of Tl-gal N-terminal CRD and C-terminal CRD are critical amino acids for recognizing carbohydrate binding, and the residues can affect protein folding and structure. The polar amino acids His, Asn, and Trp are also important residues for the interaction with carbohydrates through hydrogen bonding. Hemagglutination activities of Tl-gal were inhibited by interactions with carbohydrates and mutations. We found that the mutation of Tl-gal (E80A/E215A) at the carbohydrate binding region induced protein aggregation and could be caused in many diseases. The short linker region between the N-terminal and C-terminal CRDs of Tl-gal was very stable against proteolysis and maintained its biological activity. This structural information is expected to elucidate the carbohydrate recognition mechanism of Tl-gal and improve our understanding of anti-inflammatory mediators and modulators of immune response. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. Simultaneous measurements of work function and H‒ density including caesiation of a converter surface

    NASA Astrophysics Data System (ADS)

    Cristofaro, S.; Friedl, R.; Fantz, U.

    2017-08-01

    Negative hydrogen ion sources rely on the surface conversion of neutral atomic hydrogen and positive hydrogen ions to H-. The efficiency of this process depends on the actual work function of the converter surface. By introducing caesium into the source the work function decreases, enhancing the negative ion yield. In order to study the impact of the work function on the H- surface production at similar conditions to the ones in ion sources for fusion devices like ITER and DEMO, fundamental investigations are performed in a flexible laboratory experiment. The work function of the converter surface can be absolutely measured by photoelectric effect, while a newly installed cavity ring-down spectroscopy system (CRDS) measures the H- density. The CRDS is firstly tested and characterized by investigations on H- volume production. Caesiation of a stainless steel sample is then performed in vacuum and the plasma effect on the Cs layer is investigated also for long plasma-on times. A minimum work function of (1.9±0.1) eV is reached after some minutes of plasma treatment, resulting in a reduction by a value of 0.8 eV compared to vacuum measurements. The H- density above the surface is (2.1±0.5)×1015 m-3. With further plasma exposure of the caesiated surface, the work function increases up to 3.75 eV, due to the impinging plasma particles which gradually remove the Cs layer. As a result, the H- density decreases by a factor of at least 2.

  3. PmLT, a C-type lectin specific to hepatopancreas is involved in the innate defense of the shrimp Penaeus monodon.

    PubMed

    Ma, Tracy Hoi-Tung; Benzie, John A H; He, Jian-Guo; Chan, Siu-Ming

    2008-11-01

    A diverse class of proteins called lectins plays a major role in shrimp innate immunity. In this study, the cDNA encoding a C-type lectin of Penaeus monodon (PmLT) was cloned, and its potential role examined. Despite the low overall amino acid sequence identity with other animal lectins, PmLT includes conserved carbohydrate recognition domains (CRDs) characteristic of animal C-type lectins. Unlike the other two P. monodon lectin-like proteins described to date that have one CRD, PmLT has two CRDs. The first CRD contains a QPD motif with specificity for binding galactose, while the second CRD contains a EPN motif for binding mannose. PmLT transcripts can be detected in the hepatopancreas but not in other tissues. Expression studies showed that PmLT mRNA transcript level decreased initially and then gradually increased after whole shrimp or hepatopancreas tissue fragments were treated with white spot syndrome virus (WSSV) extract but were not affected by bacteria. Using anti-rPmLT antibody, PmLT was detected only in the hepatopancreas specific F cells (Hpf). In vitro encapsulation assay showed that agarose beads coated with rPmLT were encapsulated by hemocytes indicating a role in innate immune response. In summary, PmLT is produced in the hepatopancreas and may act as a pattern recognition protein for viral pathogens and also activates the innate immune responses of the shrimp to bacteria. The dual-CRD structure of PmLT may assist the recognition of diverse pathogens.

  4. Segment-based Mass Customization: An Exploration of a New Conceptual Marketing Framework.

    ERIC Educational Resources Information Center

    Jiang, Pingjun

    2000-01-01

    Suggests that the concept of mass customization should be seen as an integral part of market segmentation theory which offers the best way to satisfy consumers' unique needs and wants while yielding profits to companies. Proposes a new concept of "segment-based based mass customization," and offers a series of propositions which are…

  5. Diode pumped solid state lasers

    NASA Astrophysics Data System (ADS)

    Gluch, Richard P., Jr.

    1990-05-01

    I've come here today to share with you the experiences of an emerging company that has its hands around an emerging technology, and an interesting approach. And I'd like to make a few conmients today from a business aspect about the iaarketplace as they relate to our formulation of our market or business strategy. I'll share with you the direction on what the business strategy is and then trace with you some of the technical developments that are occurring at Laser Diode Products in St. Louis as they all relate directly to a customer requirernent.

  6. Superpixel-based segmentation of muscle fibers in multi-channel microscopy.

    PubMed

    Nguyen, Binh P; Heemskerk, Hans; So, Peter T C; Tucker-Kellogg, Lisa

    2016-12-05

    Confetti fluorescence and other multi-color genetic labelling strategies are useful for observing stem cell regeneration and for other problems of cell lineage tracing. One difficulty of such strategies is segmenting the cell boundaries, which is a very different problem from segmenting color images from the real world. This paper addresses the difficulties and presents a superpixel-based framework for segmentation of regenerated muscle fibers in mice. We propose to integrate an edge detector into a superpixel algorithm and customize the method for multi-channel images. The enhanced superpixel method outperforms the original and another advanced superpixel algorithm in terms of both boundary recall and under-segmentation error. Our framework was applied to cross-section and lateral section images of regenerated muscle fibers from confetti-fluorescent mice. Compared with "ground-truth" segmentations, our framework yielded median Dice similarity coefficients of 0.92 and higher. Our segmentation framework is flexible and provides very good segmentations of multi-color muscle fibers. We anticipate our methods will be useful for segmenting a variety of tissues in confetti fluorecent mice and in mice with similar multi-color labels.

  7. Toolsets for Airborne Data (TAD): Customized Data Merging Function

    NASA Astrophysics Data System (ADS)

    Benson, A.; Peeters, M. C.; Perez, J.; Parker, L.; Chen, G.

    2013-12-01

    NASA has conducted airborne tropospheric chemistry studies for about three decades. These field campaigns have generated a great wealth of observations, including a wide range of the trace gases and aerosol properties. The ASDC Toolset for Airborne Data (TAD) is being designed to meet the user community needs for manipulating aircraft data for scientific research on climate change and air quality relevant issues. Prior to the actual toolset development, a comprehensive metadata database was created to compensate for the absence of standardization of the ICARTT data format in which the data is stored. This database tracks the Principal Investigator-provided metadata, and links the measurement variables to a common naming system that was developed as a part of this project. This database is used by the data merging module. Most aircraft data reported during a single flight is not on a consistent time base and is difficult to intercompare. This module provides the user with the ability to merge original data measurements from multiple data providers into a specified time interval or common time base. The database development, common naming scheme and data merge module development will be presented.

  8. A CBR-Based and MAHP-Based Customer Value Prediction Model for New Product Development

    PubMed Central

    Zhao, Yu-Jie; Luo, Xin-xing; Deng, Li

    2014-01-01

    In the fierce market environment, the enterprise which wants to meet customer needs and boost its market profit and share must focus on the new product development. To overcome the limitations of previous research, Chan et al. proposed a dynamic decision support system to predict the customer lifetime value (CLV) for new product development. However, to better meet the customer needs, there are still some deficiencies in their model, so this study proposes a CBR-based and MAHP-based customer value prediction model for a new product (C&M-CVPM). CBR (case based reasoning) can reduce experts' workload and evaluation time, while MAHP (multiplicative analytic hierarchy process) can use actual but average influencing factor's effectiveness in stimulation, and at same time C&M-CVPM uses dynamic customers' transition probability which is more close to reality. This study not only introduces the realization of CBR and MAHP, but also elaborates C&M-CVPM's three main modules. The application of the proposed model is illustrated and confirmed to be sensible and convincing through a stimulation experiment. PMID:25162050

  9. A CBR-based and MAHP-based customer value prediction model for new product development.

    PubMed

    Zhao, Yu-Jie; Luo, Xin-xing; Deng, Li

    2014-01-01

    In the fierce market environment, the enterprise which wants to meet customer needs and boost its market profit and share must focus on the new product development. To overcome the limitations of previous research, Chan et al. proposed a dynamic decision support system to predict the customer lifetime value (CLV) for new product development. However, to better meet the customer needs, there are still some deficiencies in their model, so this study proposes a CBR-based and MAHP-based customer value prediction model for a new product (C&M-CVPM). CBR (case based reasoning) can reduce experts' workload and evaluation time, while MAHP (multiplicative analytic hierarchy process) can use actual but average influencing factor's effectiveness in stimulation, and at same time C&M-CVPM uses dynamic customers' transition probability which is more close to reality. This study not only introduces the realization of CBR and MAHP, but also elaborates C&M-CVPM's three main modules. The application of the proposed model is illustrated and confirmed to be sensible and convincing through a stimulation experiment.

  10. 47 CFR 32.2 - Basis of the accounts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (natural groupings) do take place in the course of providing products and services to customers. These... intended to permit technological distinctions. Similarly, the primary bases of plant operations, customer... products and services purchased by customers. (c) In the course of developing the bases for this account...

  11. Context-sensitive trace inlining for Java.

    PubMed

    Häubl, Christian; Wimmer, Christian; Mössenböck, Hanspeter

    2013-12-01

    Method inlining is one of the most important optimizations in method-based just-in-time (JIT) compilers. It widens the compilation scope and therefore allows optimizing multiple methods as a whole, which increases the performance. However, if method inlining is used too frequently, the compilation time increases and too much machine code is generated. This has negative effects on the performance. Trace-based JIT compilers only compile frequently executed paths, so-called traces, instead of whole methods. This may result in faster compilation, less generated machine code, and better optimized machine code. In the previous work, we implemented a trace recording infrastructure and a trace-based compiler for [Formula: see text], by modifying the Java HotSpot VM. Based on this work, we evaluate the effect of trace inlining on the performance and the amount of generated machine code. Trace inlining has several major advantages when compared to method inlining. First, trace inlining is more selective than method inlining, because only frequently executed paths are inlined. Second, the recorded traces may capture information about virtual calls, which simplify inlining. A third advantage is that trace information is context sensitive so that different method parts can be inlined depending on the specific call site. These advantages allow more aggressive inlining while the amount of generated machine code is still reasonable. We evaluate several inlining heuristics on the benchmark suites DaCapo 9.12 Bach, SPECjbb2005, and SPECjvm2008 and show that our trace-based compiler achieves an up to 51% higher peak performance than the method-based Java HotSpot client compiler. Furthermore, we show that the large compilation scope of our trace-based compiler has a positive effect on other compiler optimizations such as constant folding or null check elimination.

  12. Application of Relaxed Eddy Accumulation (REA) method to estimate CO2 and CH4 surface fluxes in the city of Krakow, southern Poland.

    NASA Astrophysics Data System (ADS)

    Zimnoch, Miroslaw; Gorczyca, Zbigniew; Pieniazek, Katarzyna; Jasek, Alina; Chmura, Lukasz; Rozanski, Kazimierz

    2013-04-01

    There is a growing interest in the recent years in studies aimed at quantifying carbon cycling in urban centres. Worldwide migration of human population from rural to urban areas and corresponding growth of extensive urban agglomerations and megacities leads to intensification of anthropogenic emissions of carbon and strong disruption of natural carbon cycle on these areas. Therefore, a deeper understanding of the carbon "metabolism" of such regions is required. Apart of better quantification of surface carbon fluxes, also a thorough understanding of the functioning of biosphere under strong anthropogenic influence is needed. Nowadays, covariance methods are widely applied for studying gas exchange between the atmosphere and the Earth's surface. Relaxed Eddy Accumulation method (REA), combined with the CO2 and CH4 CRDS analyser allows simultaneous measurements of surface fluxes of carbon dioxide and methane within the chosen footprint of the detection system, thus making possible thorough characterisation of the overall exchange of those gases between the atmosphere and the urban surface across diverse spatial and temporal scales. Here we present preliminary results of the study aimed at quantifying surface fluxes of CO2 and CH4 in Krakow, southern Poland. The REA system for CO2 and CH4 flux measurements has been installed on top of a 20m high tower mounted on the roof of the faculty building, close to the city centre of Krakow. The sensors were installed ca 42 m above the local ground. Gill Windmaster-Pro sonic anemometer was coupled with self-made system, designed by the Poznan University of Life Sciences, Poland, for collecting air samples in two pairs of 10-liter Tedlar bags, and with Picarro G2101-i CRDS analyser. The air was collected in 30-min intervals. The CO2 and CH4 mixing ratios in these cumulative downdraft and updraft air samples were determined by the CRDS analyser after each sampling interval. Based on the measured mixing ratios difference and the vertical wind component, the variability of the mean surface fluxes of CO2 and CH4 was quantified. In case of CO2 flux, a typical diurnal pattern with the maximum values of around 30 mmol m-2 h-1 occurring during night hours and the minimum values, around -40 mmol m-2 h-1, occurring early afternoon was observed during sunny days ("plus" and "minus" signs mark upward and downward fluxes, respectively). In addition, some events with much higher fluxes (up to 100 mmol m-2 h-1) were observed, mainly during rush hours. Temporal variability of methane flux turned out to be much higher than that observed for CO2. During summer, it varied from approximately -100 to +500 μmol m-2 h-1, with the mean value of around +100 μmol m-2 h-1 and maximum values occurring predominantly during daytime. In addition to flux measurements, an attempt was made to characterize also the isotopic signature of carbon in the CO2 flux components measured with the aid of REA method. The results showed that the precision of δ13CO2 measurements performed with Picarro analyser was not sufficient to differentiate the isotopic signatures of upward and downward CO2 fluxes. Acknowledgement: This work is supported by the Ministry of Science and Higher Education (project No. 817.N-COST/2010/0 and the statutory funds of the AGH University of Science and Technology, project no. 11.11.220.01).

  13. The development of a qualitative dynamic attribute value model for healthcare institutes.

    PubMed

    Lee, Wan-I

    2010-01-01

    Understanding customers has become an urgent topic for increasing competitiveness. The purpopse of the study was to develop a qualitative dynamic attribute value model which provides insight into the customers' value for healthcare institute managers by conducting the initial open-ended questionnaire survey to select participants purposefully. A total number of 427 questionnaires was conducted in two hospitals in Taiwan (one district hospital with 635 beds and one academic hospital with 2495 beds) and 419 questionnaires were received in nine weeks. Then, apply qualitative in-depth interviews to explore customers' perspective of values for building a model of partial differential equations. This study concludes nine categories of value, including cost, equipment, physician background, physicain care, environment, timing arrangement, relationship, brand image and additional value, to construct objective network for customer value and qualitative dynamic attribute value model where the network shows the value process of loyalty development via its effect on customer satisfaction, customer relationship, customer loyalty and healthcare service. One set predicts the customer relationship based on comminent, including service quality, communication and empahty. As the same time, customer loyalty based on trust, involves buzz marketing, brand and image. Customer value of the current instance is useful for traversing original customer attributes and identifing customers on different service share.

  14. Detection of nitrogen dioxide by CW cavity-enhanced spectroscopy

    NASA Astrophysics Data System (ADS)

    Jie, Guo; Han, Ye-Xing; Yu, Zhi-Wei; Tang, Huai-Wu

    2016-11-01

    In the paper, an accurate and sensitive system was used to monitor the ambient atmospheric NO2 concentrations. This system utilizes cavity attenuated phase shift spectroscopy(CAPS), a technology related to cavity ring down spectroscopy(CRDS). Advantages of the CAPS system include such as: (1) cheap and easy to control the light source, (2) high accuracy, and (3) low detection limit. The performance of the CAPS system was evaluated by measuring of the stability and response of the system. The minima ( 0.08 ppb NO2) in the Allan plots show the optimum average time( 100s) for optimum detection performance of the CAPS system. Over a 20-day-long period of the ambient atmospheric NO2 concentrations monitoring, a comparison of the CAPS system with an extremely accurate and precise chemiluminescence-based NOx analyzer showed that the CAPS system was able to reliably and quantitatively measure both large and small fluctuations in the ambient nitrogen dioxide concentration. The experimental results show that the measuring instrument results correlation is 0.95.

  15. Comparison of CEAS and Williams-type models for spring wheat yields in North Dakota and Minnesota

    NASA Technical Reports Server (NTRS)

    Barnett, T. L. (Principal Investigator)

    1982-01-01

    The CEAS and Williams-type yield models are both based on multiple regression analysis of historical time series data at CRD level. The CEAS model develops a separate relation for each CRD; the Williams-type model pools CRD data to regional level (groups of similar CRDs). Basic variables considered in the analyses are USDA yield, monthly mean temperature, monthly precipitation, and variables derived from these. The Williams-type model also used soil texture and topographic information. Technological trend is represented in both by piecewise linear functions of year. Indicators of yield reliability obtained from a ten-year bootstrap test of each model (1970-1979) demonstrate that the models are very similar in performance in all respects. Both models are about equally objective, adequate, timely, simple, and inexpensive. Both consider scientific knowledge on a broad scale but not in detail. Neither provides a good current measure of modeled yield reliability. The CEAS model is considered very slightly preferable for AgRISTARS applications.

  16. Crop weather models of corn and soybeans for Agrophysical Units (APU's) in Iowa using monthly meteorological predictors

    NASA Technical Reports Server (NTRS)

    Leduc, S. (Principal Investigator)

    1982-01-01

    Models based on multiple regression were developed to estimate corn and soybean yield from weather data for agrophysical units (APU) in Iowa. The predictor variables are derived from monthly average temperature and monthly total precipitation data at meteorological stations in the cooperative network. The models are similar in form to the previous models developed for crop reporting districts (CRD). The trends and derived variables were the same and the approach to select the significant predictors was similar to that used in developing the CRD models. The APU's were selected to be more homogeneous with respect crop to production than the CRDs. The APU models are quite similar to the CRD models, similar explained variation and number of predictor variables. The APU models are to be independently evaluated and compared to the previously evaluated CRD models. That comparison should indicate the preferred model area for this application, i.e., APU or CRD.

  17. Investigating African trace gas sources, vertical transport, and oxidation using IAGOS-CARIBIC measurements between Germany and South Africa between 2009 and 2011

    NASA Astrophysics Data System (ADS)

    Thorenz, U. R.; Baker, A. K.; Leedham Elvidge, E. C.; Sauvage, C.; Riede, H.; van Velthoven, P. F. J.; Hermann, M.; Weigelt, A.; Oram, D. E.; Brenninkmeijer, C. A. M.; Zahn, A.; Williams, J.

    2017-06-01

    Between March 2009 and March 2011 a commercial airliner equipped with a custom built measurement container (IAGOS-CARIBIC observatory) conducted 13 flights between South Africa and Germany at 10-12 km altitude, traversing the African continent north-south. In-situ measurements of trace gases (CO, CH4, H2O) and aerosol particles indicated that strong surface sources (like biomass burning) and rapid vertical transport combine to generate maximum concentrations in the latitudinal range between 10°N and 10°S coincident with the inter-tropical convergence zone (ITCZ). Pressurized air samples collected during these flights were subsequently analyzed for a suite of trace gases including C2-C8 non-methane hydrocarbons (NMHC) and halocarbons. These shorter-lived trace gases, originating from both natural and anthropogenic sources, also showed near equatorial maxima highlighting the effectiveness of convective transport in this region. Two source apportionment methods were used to investigate the specific sources of NMHC: positive matrix factorization (PMF), which is used for the first time for NMHC analysis in the upper troposphere (UT), and enhancement ratios to CO. Using the PMF method three characteristic airmass types were identified based on the different trace gas concentrations they obtained: biomass burning, fossil fuel emissions, and "background" air. The first two sources were defined with reference to previously reported surface source characterizations, while the term "background" was given to air masses in which the concentration ratios approached that of the lifetime ratios. Comparison of enhancement ratios between NMHC and CO for the subset of air samples that had experienced recent contact with the planetary boundary layer (PBL) to literature values showed that the burning of savanna and tropical forest is likely the main source of NMHC in the African upper troposphere (10-12 km). Photochemical aging patterns for the samples with PBL contact revealed that the air had different degradation histories depending on the hemisphere in which they were emitted. In the southern hemisphere (SH) air masses experienced more dilution by clean background air whereas in the northern hemisphere (NH) air masses are less diluted or mixed with background air still containing longer lived NMHC. Using NMHC photochemical clocks ozone production was seen in the BB outflow above Africa in the NH.

  18. Hand cumulative trauma disorders in Nigerian custom tailors: the need for redesign of manual scissors.

    PubMed

    Adeleye, Adedoyin Abiodun; Akanbi, Olusegun Gabriel

    2015-01-01

    Cutting scissors are important working tools for Nigerian custom tailors (CTs) but its usage apparently does not meet the ergonomics need of these artisans. A survey was carried out amongst CTs using questionnaires to obtain their background social-occupational demographics and observation methods to study their work performance, use of scissors and any cumulative trauma disorder (CTD) in their hands. Thicknesses of various fabrics were measured and comparison between Western world's custom tailoring job and the Nigerian type was done. The results showed some CTD risk factors with finger contusions on the 71 CTs evaluated. The right-hand contusions were traced to the constant usage of unpadded manual scissors with ungloved hands. Disparity between Western and Nigerian tailoring practice may account for the high occurrence of disorders in Nigerian CTs. Since hand dimensions are crucial in the design of hand tools, it is therefore concluded that hand anthropometry of Nigerian CTs and soft padding of manual scissors may mitigate CTD burdens on CTs' hands. Cumulative trauma disorders on the hands of low-income Nigerian CTs needed investigation. This was done via self-assessment and observational methods of the artisans’ work system. Frequent usage of unpadded manual scissors with un-gloved hands cause and exacerbate the problem. Hand anthropometry of users is crucial in scissors manufacturing.

  19. 41 CFR 101-28.306-2 - Use of customer supply centers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Use of customer supply... DISTRIBUTION 28.3-Customer Supply Centers § 101-28.306-2 Use of customer supply centers. (a) Orders are... requirements. All use of the CSC is based upon the customer access code assigned at the time of establishment...

  20. 47 CFR 64.5110 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... disclosing CPNI based on a customer-initiated telephone contact, TRS call, point-to-point call, online...) of this section. (c) Online access to CPNI. A TRS provider shall authenticate a customer without the... customer online access to CPNI related to his or her TRS account. Once authenticated, the customer may only...

  1. 47 CFR 64.5110 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... disclosing CPNI based on a customer-initiated telephone contact, TRS call, point-to-point call, online...) of this section. (c) Online access to CPNI. A TRS provider shall authenticate a customer without the... customer online access to CPNI related to his or her TRS account. Once authenticated, the customer may only...

  2. Optical feedback in dfb quantum cascade laser for mid-infrared cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Terabayashi, Ryohei; Sonnenschein, Volker; Tomita, Hideki; Hayashi, Noriyoshi; Kato, Shusuke; Jin, Lei; Yamanaka, Masahito; Nishizawa, Norihiko; Sato, Atsushi; Nozawa, Kohei; Hashizume, Kenta; Oh-hara, Toshinari; Iguchi, Tetsuo

    2017-11-01

    A simple external optical feedback system has been applied to a distributed feedback quantum cascade laser (DFB QCL) for cavity ring-down spectroscopy (CRDS) and a clear effect of feedback was observed. A long external feedback path length of up to 4m can decrease the QCL linewidth to around 50kHz, which is of the order of the transmission linewidth of our high finesse ring-down cavity. The power spectral density of the transmission signal from high finesse cavity reveals that the noise at frequencies above 20kHz is reduced dramatically.

  3. Opportunities and challenges for 3D printing of solid-state lighting systems

    NASA Astrophysics Data System (ADS)

    Narendran, Nadarajah; Perera, Indika U.; Mou, Xi; Thotagamuwa, Dinusha R.

    2017-09-01

    Low energy use and reduced maintenance have made the LED, a solid-state light (SSL) source, the preferred technology for many lighting applications. With the explosion of products in the marketplace and subsequent price erosion, manufacturers are looking for lower cost materials and manufacturing methods. 3-D printing, also known as additive manufacturing, could be a potential solution. Recently, manufacturers in the automotive, aerospace, and medical industries have embraced 3-D printing for manufacturing parts and systems. This could pave the way for the lighting industry to produce lower cost, custom lighting systems that are 3-D printed on-site to achieve on-time and on-demand manufacturing. One unique aspect of LED fixture manufacturing is that it requires thermo-mechanical, electrical, and optical components. The goal of our investigation was to understand if current 3-D printing technologies and materials can be used to manufacture functional thermo-mechanical, electrical, and optical components for SSL fixtures. We printed heat sink components and electrical traces using an FFF-type 3-D printer with different filaments. The results showed that the printed heat sinks achieved higher thermal conductivity values compared to components made with plastic materials. For electrical traces, graphene-infused PLA showed low resistivity but it is much higher than bulk copper resistivity. For optics, SLA-printed optical components showed that print resolution, print orientation, and postprocessing affect light transmission and light scatter properties. Overall, 3-D printing offers an opportunity for mass customization of SSL fixtures and changing architectural lighting practice, but several challenges in terms of process and materials still have to be overcome.

  4. Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft

    NASA Technical Reports Server (NTRS)

    Apel, Eric C.

    2004-01-01

    Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.

  5. Integrating sentiment analysis and term associations with geo-temporal visualizations on customer feedback streams

    NASA Astrophysics Data System (ADS)

    Hao, Ming; Rohrdantz, Christian; Janetzko, Halldór; Keim, Daniel; Dayal, Umeshwar; Haug, Lars-Erik; Hsu, Mei-Chun

    2012-01-01

    Twitter currently receives over 190 million tweets (small text-based Web posts) and manufacturing companies receive over 10 thousand web product surveys a day, in which people share their thoughts regarding a wide range of products and their features. A large number of tweets and customer surveys include opinions about products and services. However, with Twitter being a relatively new phenomenon, these tweets are underutilized as a source for determining customer sentiments. To explore high-volume customer feedback streams, we integrate three time series-based visual analysis techniques: (1) feature-based sentiment analysis that extracts, measures, and maps customer feedback; (2) a novel idea of term associations that identify attributes, verbs, and adjectives frequently occurring together; and (3) new pixel cell-based sentiment calendars, geo-temporal map visualizations and self-organizing maps to identify co-occurring and influential opinions. We have combined these techniques into a well-fitted solution for an effective analysis of large customer feedback streams such as for movie reviews (e.g., Kung-Fu Panda) or web surveys (buyers).

  6. Emotion Analysis of Telephone Complaints from Customer Based on Affective Computing.

    PubMed

    Gong, Shuangping; Dai, Yonghui; Ji, Jun; Wang, Jinzhao; Sun, Hai

    2015-01-01

    Customer complaint has been the important feedback for modern enterprises to improve their product and service quality as well as the customer's loyalty. As one of the commonly used manners in customer complaint, telephone communication carries rich emotional information of speeches, which provides valuable resources for perceiving the customer's satisfaction and studying the complaint handling skills. This paper studies the characteristics of telephone complaint speeches and proposes an analysis method based on affective computing technology, which can recognize the dynamic changes of customer emotions from the conversations between the service staff and the customer. The recognition process includes speaker recognition, emotional feature parameter extraction, and dynamic emotion recognition. Experimental results show that this method is effective and can reach high recognition rates of happy and angry states. It has been successfully applied to the operation quality and service administration in telecom and Internet service company.

  7. Emotion Analysis of Telephone Complaints from Customer Based on Affective Computing

    PubMed Central

    Gong, Shuangping; Ji, Jun; Wang, Jinzhao; Sun, Hai

    2015-01-01

    Customer complaint has been the important feedback for modern enterprises to improve their product and service quality as well as the customer's loyalty. As one of the commonly used manners in customer complaint, telephone communication carries rich emotional information of speeches, which provides valuable resources for perceiving the customer's satisfaction and studying the complaint handling skills. This paper studies the characteristics of telephone complaint speeches and proposes an analysis method based on affective computing technology, which can recognize the dynamic changes of customer emotions from the conversations between the service staff and the customer. The recognition process includes speaker recognition, emotional feature parameter extraction, and dynamic emotion recognition. Experimental results show that this method is effective and can reach high recognition rates of happy and angry states. It has been successfully applied to the operation quality and service administration in telecom and Internet service company. PMID:26633967

  8. Research on Capturing of Customer Requirements Based on Innovation Theory

    NASA Astrophysics Data System (ADS)

    junwu, Ding; dongtao, Yang; zhenqiang, Bao

    To exactly and effectively capture customer requirements information, a new customer requirements capturing modeling method was proposed. Based on the analysis of function requirement models of previous products and the application of technology system evolution laws of the Theory of Innovative Problem Solving (TRIZ), the customer requirements could be evolved from existing product designs, through modifying the functional requirement unit and confirming the direction of evolution design. Finally, a case study was provided to illustrate the feasibility of the proposed approach.

  9. A Mechanism of Modeling and Verification for SaaS Customization Based on TLA

    NASA Astrophysics Data System (ADS)

    Luan, Shuai; Shi, Yuliang; Wang, Haiyang

    With the gradually mature of SOA and the rapid development of Internet, SaaS has become a popular software service mode. The customized action of SaaS is usually subject to internal and external dependency relationships. This paper first introduces a method for modeling customization process based on Temporal Logic of Actions, and then proposes a verification algorithm to assure that each step in customization will not cause unpredictable influence on system and follow the related rules defined by SaaS provider.

  10. Wartime Transitions: Historical Case Analyses Applied to the US Campaign in Afghanistan (2001 to Present)

    DTIC Science & Technology

    2017-05-25

    operate independently without external nation support; (3) a custom approach is necessary in security forces development based on political requirements...independently without external nation support; (3) a custom approach is necessary in security forces development based on political requirements...interventions both successful and unsuccessful, that an external country must craft a custom approach to develop local security forces based on the

  11. Customized versus population-based birth weight charts for the detection of neonatal growth and perinatal morbidity in a cross-sectional study of term neonates.

    PubMed

    Carberry, Angela E; Raynes-Greenow, Camille H; Turner, Robin M; Jeffery, Heather E

    2013-10-15

    Customized birth weight charts that incorporate maternal characteristics are now being adopted into clinical practice. However, there is controversy surrounding the value of these charts in the prediction of growth and perinatal outcomes. The objective of this study was to assess the use of customized charts in predicting growth, defined by body fat percentage, and perinatal morbidity. A total of 581 term (≥37 weeks' gestation) neonates born in Sydney, Australia, in 2010 were included. Body fat percentage measurements were taken by using air displacement plethysmography. Objective composite measurements of perinatal morbidity were used to identify neonates who had poor outcomes; these data were extracted from medical records. The value of customized charts was assessed by calculating positive predictive values, negative predictive values, and odds ratios with 95% confidence intervals. Customized versus population-based charts did not improve the prediction of either low body fat percentage (59% vs. 66% positive predictive value and 87% vs. 89% negative predictive value, respectively) or high body fat percentage (48% vs. 53% positive predictive value and 90% vs. 89% negative predictive value, respectively). Customized charts were not better than population-based charts at predicting perinatal morbidity (for customized charts, odds ratio = 1.02, 95% confidence interval: 1.01, 1.04; for population-based charts, odds ratio = 1.03, 95% confidence interval: 1.01, 1.05) per percentile decrease in birth weight. Customized birth weight charts do not provide significant improvements over population-based charts in predicting neonatal growth and morbidity.

  12. Design of customer knowledge management system for Aglaonema Nursery in South Tangerang, Indonesia

    NASA Astrophysics Data System (ADS)

    Sugiarto, D.; Mardianto, I.; Dewayana, TS; Khadafi, M.

    2017-12-01

    The purpose of this paper is to describe the design of customer knowledge management system to support customer relationship management activities for an aglaonema nursery in South Tangerang, Indonesia. System. The steps were knowledge identification (knowledge about customer, knowledge from customer, knowledge for customer), knowledge capture, codification, analysis of system requirement and create use case and activity diagram. The result showed that some key knowledge were about supporting customer in plant care (know how) and types of aglaonema including with the prices (know what). That knowledge for customer then codified and shared in knowledge portal website integrated with social media. Knowledge about customer were about customers and their behaviour in purchasing aglaonema. Knowledge from customer were about feedback, favorite and customer experience. Codified knowledge were placed and shared using content management system based on wordpress.

  13. Gaining customer knowledge: obtaining and using customer judgments for hospitalwide quality improvement.

    PubMed

    Nelson, E C; Caldwell, C; Quinn, D; Rose, R

    1991-03-01

    Customer knowledge is an essential feature of hospitalwide quality improvement. All systems and processes have customers. The aim is to use customer knowledge and voice of the customer measurement to plan, design, improve, and monitor these systems and processes continuously. In this way, the hospital stands the best chance of meeting customers' needs and, hopefully, delivering services that are so outstanding that customers will be surprised and delighted. There are many methods, both soft and hard, that can be used to increase customer knowledge. One useful strategy is to use a family of quality measures that reflect the voice of the customer. These measures can generate practical and powerful customer knowledge information that is essential to performing strategic planning, deploying quality policy, designing new services, finding targets for improvements, and monitoring those continuous improvements based on customers' judgments.

  14. Long Term and High Frequency Non-Destructive Monitoring of Soil Water Stable Isotope Compositions in the Laboratory

    NASA Astrophysics Data System (ADS)

    Rothfuss, Y.; Merz, S.; Pohlmeier, A. J.; Vereecken, H.; Brueggemann, N.

    2014-12-01

    The fate and dynamics of water stable isotopologues (1H2H16O and 1H218O) are currently well implemented into physically based Soil-Vegetation-Atmosphere Transfer (SVAT) models (e.g. Hydrus 1D, SiSPAT-I, Soil-Litter iso, TOUGHREACT). However, contrary to other state variables (e.g., water content and tension) that can be monitored over long periods (e.g., by time-domain reflectometry, capacitive sensing, tensiometry or micro-psychrometry), water stable isotope compositions (δ2H and δ18O) are analyzed following destructive sampling, and thus are available only at a given time. Thus, there are important discrepancies in time resolution between soil water and stable isotope information which greatly limit the insight potential of the latter. Recently however, a technique based on direct infrared laser absorption spectroscopy was developed that allows simultaneous and direct measurements of δ2H and δ18O in water vapor. Here, we present a non-destructive method for monitoring soil liquid δ2H and δ18O by sampling and measuring water vapor equilibrated with soil water using gas-permeable polypropylene tubing and a Cavity Ring-Down laser Spectrometer (CRDS). An acrylic glass column (d=11 cm, h=60 cm) was (i) equipped with temperature and soil water probes in addition to gas-permeable tubing sections at eight different depths, (ii) filled with pure quartz sand, (iii) saturated from the bottom, and (iv) installed on weighing balances and let dry for 250 days. Each day, soil vapor δ2H and δ18O were measured for each depth by purging the soil water vapor sampled in the tubing sections with dry air and analyzing it with a CRDS. Soil liquid water δ2H and δ18O were then inferred from the values measured in the vapor. The experimental setup allowed following the evolution of the soil water δ2H and δ18O profile, which developed as a result of isotope convective capillary rise and back-diffusion of the stable isotope excess at the soil surface due to fractionating soil evaporation, with unprecedentedly high temporal resolution. As the soil dried out, we could show for the first time the increasing influence of the depleted ambient water vapor on the enriched liquid water close to the soil surface. Finally, the obtained data was simulated using the fully coupled 1D isotope-enabled SVAT model SiSPAT-Isotope.

  15. Arsenic, iron, lead, manganese, and uranium concentrations in private bedrock wells in southeastern New Hampshire, 2012-2013

    USGS Publications Warehouse

    Flanagan, Sarah M.; Belaval, Marcel; Ayotte, Joseph D.

    2014-01-01

    Trace metals, such as arsenic, iron, lead, manganese, and uranium, in groundwater used for drinking have long been a concern because of the potential adverse effects on human health and the aesthetic or nuisance problems that some present. Moderate to high concentrations of the trace metal arsenic have been identified in drinking water from groundwater sources in southeastern New Hampshire, a rapidly growing region of the State (Montgomery and others, 2003). During the past decade (2000–10), southeastern New Hampshire, which is composed of Hillsborough, Rockingham, and Strafford Counties, has grown in population by nearly 48,700 (or 6.4 percent) to 819,100. These three counties contain 62 percent of the State’s population but encompass only about 22 percent of the land area (New Hampshire Office of Energy and Planning, 2011). According to a 2005 water-use study (Hayes and Horn, 2009), about 39 percent of the population in these three counties in southeastern New Hampshire uses private wells as sources of drinking water, and these wells are not required by the State to be routinely tested for trace metals or other contaminants. Some trace metals have associated human-health benchmarks or nonhealth guidelines that have been established by the U.S. Environmental Protection Agency (EPA) to regulate public water supplies. The EPA has established a maximum contaminant level (MCL) of 10 micrograms per liter (μg/L) for arsenic (As) and a MCL of 30 μg/L for uranium (U) because of associated health risks (U.S. Environmental Protection Agency, 2012). Iron (Fe) and manganese (Mn) are essential for human health, but Mn at high doses may have adverse cognitive effects in children (Bouchard and others, 2011; Agency for Toxic Substances and Disease Registry, 2012); therefore, the EPA has issued a lifetime health advisory (LHA) of 300 μg/L for Mn. Recommended secondary maximum contaminant levels (SMCLs) for Fe (300 μg/L) and Mn (50 μg/L) were established primarily as nonhealth guidelines—based on aesthetic considerations, such as taste or the staining of laundry and plumbing fixtures—because these contaminants, at the SMCLs, are not considered to present risks to human health. Because lead (Pb) contamination of drinking water typically results from corrosion of plumbing materials belonging to water-system customers but still poses a risk to human health, the EPA established an action level (AL) of 15 μg/L for Pb instead of an MCL or SMCL (U.S. Environmental Protection Agency, 2012). The 15-μg/L AL for Pb has been adopted by the New Hampshire Department of Environmental Services for public water systems, and if exceeded, the public water system must inform their customers and undertake additional actions to control corrosion in the pipes of the distribution system (New Hampshire Department of Environmental Services, 2013). Unlike the quality of drinking water provided by public water suppliers, the quality of drinking water obtained from private wells in New Hampshire is not regulated; consequently, private wells are sampled only when individual well owners voluntarily choose to sample them. The U.S. Geological Survey (USGS), in cooperation with the EPA New England, conducted an assessment in 2012–13 to provide private well owners and State and Federal health officials with information on the distribution of trace-metal (As, Fe, Pb, Mn, and U) concentrations in groundwater from bedrock aquifers in the three counties of southeastern New Hampshire. This fact sheet analyzes data from water samples collected by a randomly selected group of private well owners from the three-county study area and describes the major findings for trace-metal concentrations.

  16. 75 FR 69791 - Risk Management Controls for Brokers or Dealers With Market Access

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... relationship with the ultimate customer, can more effectively implement them. In addition, a broker or dealer... specific risk management controls and supervisory procedures to a customer that is a registered broker... such customer, based on its position in the transaction and relationship with the ultimate customer...

  17. Printed Graphene Derivative Circuits as Passive Electrical Filters

    PubMed Central

    Sinar, Dogan

    2018-01-01

    The objective of this study is to inkjet print resistor-capacitor (RC) low pass electrical filters, using a novel water-based cellulose graphene ink, and compare the voltage-frequency and transient behavior to equivalent circuits constructed from discrete passive components. The synthesized non-toxic graphene-carboxymethyl cellulose (G-CMC) ink is deposited on mechanically flexible polyimide substrates using a customized printer that dispenses functionalized aqueous solutions. The design of the printed first-order and second-order low-pass RC filters incorporate resistive traces and interdigitated capacitors. Low pass filter characteristics, such as time constant, cut-off frequency and roll-off rate, are determined for comparative analysis. Experiments demonstrate that for low frequency applications (<100 kHz) the printed graphene derivative circuits performed as well as the circuits constructed from discrete resistors and capacitors for both low pass filter and RC integrator applications. The impact of mechanical stress due to bending on the electrical performance of the flexible printed circuits is also investigated. PMID:29473890

  18. Capillary zone electrophoresis-tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies

    PubMed Central

    Zhu, Guijie; Sun, Liangliang; Heidbrink-Thompson, Jennifer; Kuntumalla, Srilatha; Lin, Hung-yu; Larkin, Christopher J.; McGivney, James B.; Dovichi, Norman J.

    2016-01-01

    We have evaluated capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a five-point calibration curve by spiking twelve standard proteins into a solution of a human monoclonal antibody. A custom CZE-MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a ~70 min separation window (~90 min total analysis duration) and ~300 peak capacity. We also analyzed the sample using ultra-performance liquid chromatography (UPLC)-MS/MS. CZE-MS/MS generated ~five times higher base peak intensity and more peptide identifications for low-level spiked proteins. Both methods detected all proteins spiked at the ~100 ppm level with respect to the antibody. PMID:26530276

  19. Wavefront Measurement in Ophthalmology

    NASA Astrophysics Data System (ADS)

    Molebny, Vasyl

    Wavefront sensing or aberration measurement in the eye is a key problem in refractive surgery and vision correction with laser. The accuracy of these measurements is critical for the outcome of the surgery. Practically all clinical methods use laser as a source of light. To better understand the background, we analyze the pre-laser techniques developed over centuries. They allowed new discoveries of the nature of the optical system of the eye, and many served as prototypes for laser-based wavefront sensing technologies. Hartmann's test was strengthened by Platt's lenslet matrix and the CCD two-dimensional photodetector acquired a new life as a Hartmann-Shack sensor in Heidelberg. Tscherning's aberroscope, invented in France, was transformed into a laser device known as a Dresden aberrometer, having seen its reincarnation in Germany with Seiler's help. The clinical ray tracing technique was brought to life by Molebny in Ukraine, and skiascopy was created by Fujieda in Japan. With the maturation of these technologies, new demands now arise for their wider implementation in optometry and vision correction with customized contact and intraocular lenses.

  20. Printed Graphene Derivative Circuits as Passive Electrical Filters.

    PubMed

    Sinar, Dogan; Knopf, George K

    2018-02-23

    The objective of this study is to inkjet print resistor-capacitor ( RC ) low pass electrical filters, using a novel water-based cellulose graphene ink, and compare the voltage-frequency and transient behavior to equivalent circuits constructed from discrete passive components. The synthesized non-toxic graphene-carboxymethyl cellulose (G-CMC) ink is deposited on mechanically flexible polyimide substrates using a customized printer that dispenses functionalized aqueous solutions. The design of the printed first-order and second-order low-pass RC filters incorporate resistive traces and interdigitated capacitors. Low pass filter characteristics, such as time constant, cut-off frequency and roll-off rate, are determined for comparative analysis. Experiments demonstrate that for low frequency applications (<100 kHz) the printed graphene derivative circuits performed as well as the circuits constructed from discrete resistors and capacitors for both low pass filter and RC integrator applications. The impact of mechanical stress due to bending on the electrical performance of the flexible printed circuits is also investigated.

  1. A Systems Modeling Approach for Risk Management of Command File Errors

    NASA Technical Reports Server (NTRS)

    Meshkat, Leila

    2012-01-01

    The main cause of commanding errors is often (but not always) due to procedures. Either lack of maturity in the processes, incompleteness of requirements or lack of compliance to these procedures. Other causes of commanding errors include lack of understanding of system states, inadequate communication, and making hasty changes in standard procedures in response to an unexpected event. In general, it's important to look at the big picture prior to making corrective actions. In the case of errors traced back to procedures, considering the reliability of the process as a metric during its' design may help to reduce risk. This metric is obtained by using data from Nuclear Industry regarding human reliability. A structured method for the collection of anomaly data will help the operator think systematically about the anomaly and facilitate risk management. Formal models can be used for risk based design and risk management. A generic set of models can be customized for a broad range of missions.

  2. Extinction cross section measurements for a single optically trapped particle

    NASA Astrophysics Data System (ADS)

    Cotterell, Michael I.; Preston, Thomas C.; Mason, Bernard J.; Orr-Ewing, Andrew J.; Reid, Jonathan P.

    2015-08-01

    Bessel beam (BB) optical traps have become widely used to confine single and multiple aerosol particles across a broad range of sizes, from a few microns to < 200 nm in radius. The radiation pressure force exerted by the core of a single, zeroth-order BB incident on a particle can be balanced by a counter-propagating gas flow, allowing a single particle to be trapped indefinitely. The pseudo non-diffracting nature of BBs enables particles to be confined over macroscopic distances along the BB core propagation length; the position of the particle along this length can be finely controlled by variation of the BB laser power. This latter property is exploited to optimize the particle position at the center of the TEM00 mode of a high finesse optical cavity, allowing cavity ring-down spectroscopy (CRDS) to be performed on single aerosol particles and their optical extinction cross section, σext, measured. Further, the variation in the light from the illuminating BB elastically scattered by the particle is recorded as a function of scattering angle. Such intensity distributions are fitted to Lorenz-Mie theory to determine the particle radius. The trends in σext with particle radius are modelled using cavity standing wave Mie simulations and a particle's varying refractive index with changing relative humidity is determined. We demonstrate σext measurements on individual sub-micrometer aerosol particles and determine the lowest limit in particle size that can be probed by this technique. The BB-CRDS method will play a key role in reducing the uncertainty associated with atmospheric aerosol radiative forcing, which remains among the largest uncertainties in climate modelling.

  3. Inhibition of Wnt/β-Catenin Signaling by a Soluble Collagen-Derived Frizzled Domain Interacting with Wnt3a and the Receptors Frizzled 1 and 8

    PubMed Central

    Hendaoui, Ismaïl; Lavergne, Elise; Lee, Heun-Sik; Hong, Seong Hyun; Kim, Hak-Zoo; Parent, Christelle; Heuzé-Vourc'h, Nathalie; Clément, Bruno; Musso, Orlando

    2012-01-01

    The Wnt/β-catenin pathway controls cell proliferation, death and differentiation. Several families of extracellular proteins can antagonize Wnt/β-catenin signaling, including the decoy receptors known as secreted frizzled related proteins (SFRPs), which have a cysteine-rich domain (CRD) structurally similar to the extracellular Wnt-binding domain of the frizzled receptors. SFRPs inhibit Wnt signaling by sequestering Wnts through the CRD or by forming inactive complexes with the frizzled receptors. Other endogenous molecules carrying frizzled CRDs inhibit Wnt signaling, such as V3Nter, which is proteolytically derived from the cell surface component collagen XVIII and contains a biologically active frizzled domain (FZC18) inhibiting in vivo cell proliferation and tumor growth in mice. We recently showed that FZC18 expressing cells deliver short-range signals to neighboring cells, decreasing their proliferation in vitro and in vivo through the Wnt/β-catenin signaling pathway. Here, using low concentrations of soluble FZC18 and Wnt3a, we show that they physically interact in a cell-free system. In addition, soluble FZC18 binds the frizzled 1 and 8 receptors' CRDs, reducing cell sensitivity to Wnt3a. Conversely, inhibition of Wnt/β-catenin signaling was partially rescued by the expression of full-length frizzled 1 and 8 receptors, but enhanced by the expression of a chimeric cell-membrane-tethered frizzled 8 CRD. Moreover, soluble, partially purified recombinant FZC18_CRD inhibited Wnt3a-induced β-catenin activation. Taken together, the data indicate that collagen XVIII-derived frizzled CRD shifts Wnt sensitivity of normal cells to a lower pitch and controls their growth. PMID:22303445

  4. Water vapor self-continuum absorption measurements in the 4.0 and 2.1 μm transparency windows

    NASA Astrophysics Data System (ADS)

    Richard, L.; Vasilchenko, S.; Mondelain, D.; Ventrillard, I.; Romanini, D.; Campargue, A.

    2017-11-01

    In a recent contribution [A. Campargue, S. Kassi, D. Mondelain, S. Vasilchenko, D. Romanini, Accurate laboratory determination of the near infrared water vapor self-continuum: A test of the MT_CKD model. J. Geophys. Res. Atmos., 121,13,180-13,203, doi:10.1002/2016JD025531], we reported accurate water vapor absorption continuum measurements by Cavity Ring-down Spectroscopy (CRDS) and Optical-Feedback-Cavity Enhanced Absorption Spectroscopy (OF-CEAS) at selected spectral points of 4 near infrared transparency windows. In the present work, the self-continuum cross-sections, CS, are determined for two new spectral points. The 2491 cm-1 spectral point in the region of maximum transparency of the 4.0 μm window was measured by OF-CEAS in the 23-52 °C temperature range. The 4435 cm-1 spectral point of the 2.1 μm window was measured by CRDS at room temperature. The self-continuum cross-sections were determined from the pressure squared dependence of the continuum absorption. Comparison to the literature shows a reasonable agreement with 1970 s and 1980 s measurements using a grating spectrograph in the 4.0 μm window and a very good consistency with our previous laser measurements in the 2.1 μm window. For both studied spectral points, our values are much smaller than previous room temperature measurements by Fourier Transform Spectroscopy. Significant deviations (up to about a factor 4) are noted compared to the widely used semi empirical MT_CKD model of the absorption continuum. The measured temperature dependence at 2491 cm-1 is consistent with previous high temperature measurements in the 4.0 μm window and follows an exp(D0/kT) law, D0 being the dissociation energy of the water dimer.

  5. Physical and Mathematical Methods for Removing Organic Interference from Optical Isotope Measurements

    NASA Astrophysics Data System (ADS)

    Hsiao, G.; Chappellet-Volini, L.; Vu, D.

    2012-12-01

    Portable high precision isotope analyzers using CRDS technology have greatly increased the use of stable isotopes in hydrological, oceanographic, and ecological studies over the past five years. However studies of some water samples yielded incorrect isotopic values indicating some form of spectroscopic interference. Subsequent work has shown that waters derived from some plants containing interfering alcohols but meteoric waters are not affected. The initial approach to handling such samples was to use spectroscopic anomalies to identify and flag affected samples for later analysis by non-optical methods. This presentation will examine the approaches developed within the past year to allow for accurate analysis of such samples by optical methods. The first approach uses an advanced spectroscopic model to identify and quantify alcohols present in the sample. The alcohol signal is incorporated into the overall fit of the measure spectra to calculate the concentration of the individual isotopes. It was found that the δ18O value could be calculated with high accuracy, the result for the δ2H value was sufficient for many applications. The second approach uses physical treatment of the sample to break down the organic molecules into non-interfering species. The liquid sample is injected into a flash vaporizer then the vapor travels through a cartridge for physical treatment prior to analysis by CRDS. Inside the cartridge the organic molecules undergo oxidation at high temperature in the air carrier gas when exposed to the catalyst. This approach is highly effective for ethanol solutions as high as 5% as well as for the complex mixtures of alcohols found in plants. Comparison of the results of both of these methods will be compared with tertiary techniques such as IRMS where possible.

  6. A new C-type lectin (FcLec5) from the Chinese white shrimp Fenneropenaeus chinensis.

    PubMed

    Xu, Wen-Teng; Wang, Xian-Wei; Zhang, Xiao-Wen; Zhao, Xiao-Fan; Yu, Xiao-Qiang; Wang, Jin-Xing

    2010-11-01

    C-type lectins are one family of pattern recognition receptors (PRRs) that play important roles in innate immunity. In this work, cDNA and genomic sequences for a new C-type lectin (FcLec5) were obtained from the Chinese white shrimp Fenneropenaeus chinensis. FcLec5 cDNA contains an open reading frame of 1,008 bp and its genomic sequence is 1,137 bp with 4 exons and 3 introns. The predicted FcLec5 protein contains a signal peptide and two carbohydrate recognition domains (CRDs). The N-terminal CRD of FcLec5 has a predicted carbohydrate recognition motif of Gln-Pro-Asp (QPD), while the C-terminal CRD contains a motif of Glu-Pro-Gln (EPQ). Northern blot analysis showed that FcLec5 mRNA was specifically expressed in hepatopancreas. FcLec5 protein was expressed in hepatopancreas and secreted into hemolymph. Real-time PCR showed that FcLec5 transcript exhibited different expression profiles after immune-challenged with Vibrio anguillarum or White Spot Syndrome Virus (WSSV). Recombinant FcLec5 and its two individual CRDs could agglutinate most bacteria tested, and the agglutinating activity was Ca2+-dependent. Besides, the agglutinating activity to gram-negative bacteria is higher than that to gram-positive bacteria. Direct binding assay showed that recombinant FcLec5 could bind to all microorganisms tested (five gram-positive and four gram-negative bacteria, as well as yeast) in a Ca2+-independent manner. Recombinant FcLec5 also directly bound to bacterial peptidoglycan, lipopolysaccharide and lipoteichoic acids. These results suggest that FcLec5 may act as a PRR for bacteria via binding to bacterial cell wall polysaccharides in Chinese white shrimp.

  7. Experimental study on trace chemical contaminant generation rates of human metabolism in spacecraft crew module

    NASA Astrophysics Data System (ADS)

    Lihua, Guo; Xinxing, He; Guoxin, Xu; Xin, Qi

    2012-12-01

    Trace chemical contaminants generated by human metabolism is a major source of contamination in spacecraft crew module. In this research, types and generation rates of pollutants from human metabolism were determined in the Chinese diets. Expired air, skin gas, and sweat of 20 subjects were analyzed at different exercise states in a simulated module. The exercise states were designed according to the basic activities in the orbit of astronauts. Qualitative and quantitative analyses of contaminants generated by human metabolic were performed with gas chromatography/mass spectrometry, gas chromatography and UV spectrophotometer. Sixteen chemical compounds from metabolic sources were found. With the increase in physical load, the concentrations of chemical compounds from human skin and expired air correspondingly increased. The species and the offgassing rates of pollutants from human metabolism are different among the Chinese, Americans and the Russians due to differences in ethnicity and dietary customs. This research provides data to aid in the design, development and operation of China's long duration space mission.

  8. Sensitivity of RF-driven Plasma Filaments to Trace Gases

    NASA Astrophysics Data System (ADS)

    Burin, M. J.; Czarnocki, C. J.; Czarnocki, K.; Zweben, S. J.; Zwicker, A.

    2011-10-01

    Filamentary structures have been observed in many types of plasma discharges in both natural (e.g. lightning) and industrial systems (e.g. dielectric barrier discharges). Recent progress has been made in characterizing these structures, though various aspects of their essential physics remain unclear. A common example of this phenomenon can be found within a toy plasma globe (or plasma ball), wherein a primarily neon gas mixture near atmospheric pressure clearly and aesthetically displays filamentation. Recent work has provided the first characterization of these plasma globe filaments [Campanell et al., Physics of Plasmas 2010], where it was noticed that discharges of pure gases tend not to produce filaments. We have extended this initial work to investigate in greater detail the dependence of trace gases on filamentation within a primarily Neon discharge. Our preliminary results using a custom globe apparatus will be presented, along with some discussion of voltage dependencies. Newly supported by the NSF/DOE Partnership in Basic Plasma Science and Engineering.

  9. Behavior of suspended particles in the Changjiang Estuary: Size distribution and trace metal contamination.

    PubMed

    Yao, Qingzhen; Wang, Xiaojing; Jian, Huimin; Chen, Hongtao; Yu, Zhigang

    2016-02-15

    Suspended particulate matter (SPM) samples were collected along a salinity gradient in the Changjiang Estuary in June 2011. A custom-built water elutriation apparatus was used to separate the suspended sediments into five size fractions. The results indicated that Cr and Pb originated from natural weathering processes, whereas Cu, Zn, and Cd originated from other sources. The distribution of most trace metals in different particle sizes increased with decreasing particle size. The contents of Fe/Mn and organic matter were confirmed to play an important role in increasing the level of heavy metal contents. The Cu, Pb, Zn, and Cd contents varied significantly with increasing salinity in the medium-low salinity region, thus indicating the release of Cu, Pb, Zn, and Cd particles. Thus, the transfer of polluted fine particles into the open sea is probably accompanied by release of pollutants into the dissolved compartment, thereby amplifying the potential harmful effects to marine organisms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. A Practical Guide for Managing Customer Service in Base Civil Engineering.

    DTIC Science & Technology

    1988-04-01

    IMPROVING CUSTOMER SERVICE IN BASE CIVIL ENGINEERING Step One: Evaluate Present Service Quality .. ......... .11 Step Two: Develop and Clarify a...cross sectional viewpoint. In chapter three, specific steps will be presented for managers to evaluate and improve the present level of service quality in...customer service in base civil engineering or any other organization for that matter is to evaluate the present level of service quality (1:170). Data

  11. A customer satisfaction model for a utility service industry

    NASA Astrophysics Data System (ADS)

    Jamil, Jastini Mohd; Nawawi, Mohd Kamal Mohd; Ramli, Razamin

    2016-08-01

    This paper explores the effect of Image, Customer Expectation, Perceived Quality and Perceived Value on Customer Satisfaction, and to investigate the effect of Image and Customer Satisfaction on Customer Loyalty of mobile phone provider in Malaysia. The result of this research is based on data gathered online from international students in one of the public university in Malaysia. Partial Least Squares Structural Equation Modeling (PLS-SEM) has been used to analyze the data that have been collected from the international students' perceptions. The results found that Image and Perceived Quality have significant impact on Customer Satisfaction. Image and Customer Satisfaction ware also found to have significantly related to Customer Loyalty. However, no significant impact has been found between Customer Expectation with Customer Satisfaction, Perceived Value with Customer Satisfaction, and Customer Expectation with Perceived Value. We hope that the findings may assist the mobile phone provider in production and promotion of their services.

  12. Flow immune photoacoustic sensor for real-time and fast sampling of trace gases

    NASA Astrophysics Data System (ADS)

    Petersen, Jan C.; Balslev-Harder, David; Pelevic, Nikola; Brusch, Anders; Persijn, Stefan; Lassen, Mikael

    2018-02-01

    A photoacoustic (PA) sensor for fast and real-time gas sensing is demonstrated. The PA cell has been designed for flow noise immunity using computational fluid dynamics (CFD) analysis. PA measurements were conducted at different flow rates by exciting molecular C-H stretch vibrational bands of hexane (C6H14) in clean air at 2950cm-1 (3.38 μm) with a custom made mid-infrared interband cascade laser (ICL). The PA sensor will contribute to solve a major problem in a number of industries using compressed air by the detection of oil contaminants in high purity compressed air. We observe a (1σ, standard deviation) sensitivity of 0.4 +/-0.1 ppb (nmol/mol) for hexane in clean air at flow rates up to 2 L/min, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 2.5×10-9 W cm-1 Hz1/2, thus demonstrating high sensitivity and fast and real-time gas analysis. The PA sensor is not limited to molecules with C-H stretching modes, but can be tailored to measure any trace gas by simply changing the excitation wavelength (i.e. the laser source) making it useful for many different applications where fast and sensitive trace gas measurements are needed.

  13. Competition.

    PubMed

    Chambers, D W

    1997-01-01

    Our ambivalence toward competition can be traced to an unspoken preference for certain types of competition which give us an advantage over the types we value less. Four types are defined (a) pure (same rules, same objectives), (b) collaborative (same rules, shared objective), (c) market share (different rules, same objectives), and (d) market growth (different rules, value added orientation). The defining characteristics of the four types of competition are respectively: needing a referee, arguing over the spoils, differentiation and substitutability, and customer focus. Dentistry has features of all four types of competition, thus making it difficult to have a meaningful discussion or frame a coherent policy on this topic.

  14. Genetically Encoded Fragment-Based Discovery of Glycopeptide Ligands for Carbohydrate-Binding Proteins

    DOE PAGES

    Ng, Simon; Lin, Edith; Kitov, Pavel I.; ...

    2015-04-10

    Here we describe an approach to accelerate the search for competitive inhibitors for carbohydrate-recognition domains (CRDs). Genetically encoded fragment-based-discovery (GE-FBD) uses selection of phagedisplayed glycopeptides to dock a glycan fragment at the CRD and guide selection of Synergistic peptide motifs adjacent to the CRD. Starting from concanavalin A (ConA), a mannose (Man)-binding protein, as a bait, we narrowed a library of 10 8 glycopeptides to 86 leads that share a consensus motif, Man-WYD. Validation of synthetic leads yielded Man-WYDLF that exhibited 40 50-fold enhancement in affinity over methyl α-D-mannopyranoside (MeMan). Lectin array Suggested specificity: Man-WYD derivative bound only to 3more » out of 17 proteins-ConA, LcH, and PSA-that bind to Man. An X-ray structure of ConA.:Man-WYD proved that the trimannoside core and Man-WYD exhibit identical CRD docking; but their extra-CRD binding modes are significantly. different. Still, they have comparable affinity and selectivity for various Man-binding proteins. The intriguing observation provides new insight into functional mimicry :of carbohydrates by peptide ligands. GE-FBD may provide an alternative to rapidly search for competitive inhibitors for lectins.« less

  15. Genetically Encoded Fragment-Based Discovery of Glycopeptide Ligands for Carbohydrate-Binding Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Simon; Lin, Edith; Kitov, Pavel I.

    Here we describe an approach to accelerate the search for competitive inhibitors for carbohydrate-recognition domains (CRDs). Genetically encoded fragment-based-discovery (GE-FBD) uses selection of phagedisplayed glycopeptides to dock a glycan fragment at the CRD and guide selection of Synergistic peptide motifs adjacent to the CRD. Starting from concanavalin A (ConA), a mannose (Man)-binding protein, as a bait, we narrowed a library of 10 8 glycopeptides to 86 leads that share a consensus motif, Man-WYD. Validation of synthetic leads yielded Man-WYDLF that exhibited 40 50-fold enhancement in affinity over methyl α-D-mannopyranoside (MeMan). Lectin array Suggested specificity: Man-WYD derivative bound only to 3more » out of 17 proteins-ConA, LcH, and PSA-that bind to Man. An X-ray structure of ConA.:Man-WYD proved that the trimannoside core and Man-WYD exhibit identical CRD docking; but their extra-CRD binding modes are significantly. different. Still, they have comparable affinity and selectivity for various Man-binding proteins. The intriguing observation provides new insight into functional mimicry :of carbohydrates by peptide ligands. GE-FBD may provide an alternative to rapidly search for competitive inhibitors for lectins.« less

  16. The Development of a Qualitative Dynamic Attribute Value Model for Healthcare Institutes

    PubMed Central

    Lee, Wan-I

    2010-01-01

    Background: Understanding customers has become an urgent topic for increasing competitiveness. The purpopse of the study was to develop a qualitative dynamic attribute value model which provides insight into the customers’ value for healthcare institute managers by conducting the initial open-ended questionnaire survey to select participants purposefully. Methods: A total number of 427 questionnaires was conducted in two hospitals in Taiwan (one district hospital with 635 beds and one academic hospital with 2495 beds) and 419 questionnaires were received in nine weeks. Then, apply qualitative in-depth interviews to explore customers’ perspective of values for building a model of partial differential equations. Results: This study concludes nine categories of value, including cost, equipment, physician background, physicain care, environment, timing arrangement, relationship, brand image and additional value, to construct objective network for customer value and qualitative dynamic attribute value model where the network shows the value process of loyalty development via its effect on customer satisfaction, customer relationship, customer loyalty and healthcare service. Conclusion: One set predicts the customer relationship based on comminent, including service quality, communication and empahty. As the same time, customer loyalty based on trust, involves buzz marketing, brand and image. Customer value of the current instance is useful for traversing original customer attributes and identifing customers on different service share. PMID:23113034

  17. Demand forecast model based on CRM

    NASA Astrophysics Data System (ADS)

    Cai, Yuancui; Chen, Lichao

    2006-11-01

    With interiorizing day by day management thought that regarding customer as the centre, forecasting customer demand becomes more and more important. In the demand forecast of customer relationship management, the traditional forecast methods have very great limitation because much uncertainty of the demand, these all require new modeling to meet the demands of development. In this paper, the notion is that forecasting the demand according to characteristics of the potential customer, then modeling by it. The model first depicts customer adopting uniform multiple indexes. Secondly, the model acquires characteristic customers on the basis of data warehouse and the technology of data mining. The last, there get the most similar characteristic customer by their comparing and forecast the demands of new customer by the most similar characteristic customer.

  18. 14 CFR § 1214.107 - Postponement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Provisions Regarding Space Shuttle Flights of Payloads for Non-U.S. Government, Reimbursable Customers § 1214... customer. (b) A customer postponing the flight of a payload will pay a postponement fee to NASA. The fee will be computed as a percentage of the customer's Shuttle standard flight price and will be based on...

  19. Case study: the health SmartLibrary experiences in web personalization and customization at the Galter health sciences library, Northwestern University.

    PubMed

    Shedlock, James; Frisque, Michelle; Hunt, Steve; Walton, Linda; Handler, Jonathan; Gillam, Michael

    2010-04-01

    How can the user's access to health information, especially full-text articles, be improved? The solution is building and evaluating the Health SmartLibrary (HSL). The setting is the Galter Health Sciences Library, Feinberg School of Medicine, Northwestern University. The HSL was built on web-based personalization and customization tools: My E-Resources, Stay Current, Quick Search, and File Cabinet. Personalization and customization data were tracked to show user activity with these value-added, online services. Registration data indicated that users were receptive to personalized resource selection and that the automated application of specialty-based, personalized HSLs was more frequently adopted than manual customization by users. Those who did customize customized My E-Resources and Stay Current more often than Quick Search and File Cabinet. Most of those who customized did so only once. Users did not always take advantage of the services designed to aid their library research experiences. When personalization is available at registration, users readily accepted it. Customization tools were used less frequently; however, more research is needed to determine why this was the case.

  20. American Recovery and Reinvestment Act of 2009. Interim Report on Customer Acceptance, Retention, and Response to Time-Based Rates from the Consumer Behavior Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappers, Peter; Hans, Liesel; Scheer, Richard

    Time-based rate programs1, enabled by utility investments in advanced metering infrastructure (AMI), are increasingly being considered by utilities as tools to reduce peak demand and enable customers to better manage consumption and costs. There are several customer systems that are relatively new to the marketplace and have the potential for improving the effectiveness of these programs, including in-home displays (IHDs), programmable communicating thermostats (PCTs), and web portals. Policy and decision makers are interested in more information about customer acceptance, retention, and response before moving forward with expanded deployments of AMI-enabled new rates and technologies. Under the Smart Grid Investment Grantmore » Program (SGIG), the U.S. Department of Energy (DOE) partnered with several utilities to conduct consumer behavior studies (CBS). The goals involved applying randomized and controlled experimental designs for estimating customer responses more precisely and credibly to advance understanding of time-based rates and customer systems, and provide new information for improving program designs, implementation strategies, and evaluations. The intent was to produce more robust and credible analysis of impacts, costs, benefits, and lessons learned and assist utility and regulatory decision makers in evaluating investment opportunities involving time-based rates. To help achieve these goals, DOE developed technical guidelines to help the CBS utilities estimate customer acceptance, retention, and response more precisely.« less

  1. iHelp: an intelligent online helpdesk system.

    PubMed

    Wang, Dingding; Li, Tao; Zhu, Shenghuo; Gong, Yihong

    2011-02-01

    Due to the importance of high-quality customer service, many companies use intelligent helpdesk systems (e.g., case-based systems) to improve customer service quality. However, these systems face two challenges: 1) Case retrieval measures: most case-based systems use traditional keyword-matching-based ranking schemes for case retrieval and have difficulty to capture the semantic meanings of cases and 2) result representation: most case-based systems return a list of past cases ranked by their relevance to a new request, and customers have to go through the list and examine the cases one by one to identify their desired cases. To address these challenges, we develop iHelp, an intelligent online helpdesk system, to automatically find problem-solution patterns from the past customer-representative interactions. When a new customer request arrives, iHelp searches and ranks the past cases based on their semantic relevance to the request, groups the relevant cases into different clusters using a mixture language model and symmetric matrix factorization, and summarizes each case cluster to generate recommended solutions. Case and user studies have been conducted to show the full functionality and the effectiveness of iHelp.

  2. Determinants of Quality Perception in Educational Administration: Potential Conflict between the Requirements of Internal and External Customers.

    ERIC Educational Resources Information Center

    Galloway, R. L.; Wearn, Katrina

    1998-01-01

    Attempts to measure perceived quality, based on customers' views within the context of a (British) university faculty office, using a modified SERVQUAL instrument. Internal customers demonstrated that perceived quality is driven by task-focused issues, stressing clarity, accuracy, and reliability. External customers, whose usage is more casual,…

  3. The Impact of IT Capability on Employee Capability, Customer Value, Customer Satisfaction, and Business Performance

    ERIC Educational Resources Information Center

    Chae, Ho-Chang

    2009-01-01

    This study empirically examines the impact of IT capability on firms' performance and evaluates whether firms' IT capabilities play a role in improving employee capability, customer value, customer satisfaction, and ultimately business performance. The results were based on comparing the business performance of the IT leader companies with that of…

  4. The Species and Origin of Shark Fins in Taiwan's Fishing Ports, Markets, and Customs Detention: A DNA Barcoding Analysis.

    PubMed

    Chuang, Po-Shun; Hung, Tzu-Chiao; Chang, Hung-An; Huang, Chien-Kang; Shiao, Jen-Chieh

    2016-01-01

    The increasing consumption of shark products, along with the shark's fishing vulnerabilities, has led to the decrease in certain shark populations. In this study we used a DNA barcoding method to identify the species of shark landings at fishing ports, shark fin products in retail stores, and shark fins detained by Taiwan customs. In total we identified 23, 24, and 14 species from 231 fishing landings, 316 fin products, and 113 detained shark fins, respectively. All the three sample sources were dominated by Prionace glauca, which accounted for more than 30% of the collected samples. Over 60% of the species identified in the fin products also appeared in the port landings, suggesting the domestic-dominance of shark fin products in Taiwan. However, international trade also contributes a certain proportion of the fin product markets, as four species identified from the shark fin products are not found in Taiwan's waters, and some domestic-available species were also found in the customs-detained sample. In addition to the species identification, we also found geographical differentiation in the cox1 gene of the common thresher sharks (Alopias vulpinus), the pelagic thresher shark (A. pelagicus), the smooth hammerhead shark (Sphyrna zygaena), and the scalloped hammerhead shark (S. lewini). This result might allow fishing authorities to more effectively trace the origins as well as enforce the management and conservation of these sharks.

  5. Customization of a generic 3D model of the distal femur using diagnostic radiographs.

    PubMed

    Schmutz, B; Reynolds, K J; Slavotinek, J P

    2008-01-01

    A method for the customization of a generic 3D model of the distal femur is presented. The customization method involves two steps: acquisition of calibrated orthogonal planar radiographs; and linear scaling of the generic model based on the width of a subject's femoral condyles as measured on the planar radiographs. Planar radiographs of seven intact lower cadaver limbs were obtained. The customized generic models were validated by comparing their surface geometry with that of CT-reconstructed reference models. The overall mean error was 1.2 mm. The results demonstrate that uniform scaling as a first step in the customization process produced a base model of accuracy comparable to other models reported in the literature.

  6. Portable Cavity Ringdown Spectrometer for Methane Isotope Ratio Measurements

    NASA Astrophysics Data System (ADS)

    Bostrom, G.; Rice, A.; Atkinson, D.

    2008-12-01

    Close to 45% (244 Tg/yr) of the methange (CH4) in the atmosphere is produced in anaerobic soil conditions (wetlands and rice paddies). Under aerobic soil conditions, bacteria oxidize CH4 to produce CO2 and H2O. Both production and oxidation rates depend on soil composition, nutrient loadings, water content, and plant conditions, but these dependencies are not well characterized. Measurements of CH4 isotope ratios can provide a better understanding of CH4 processes in natural and man- made ecosystems. Here we present progress on the development of a field deployable instrument capable of making precision 13CH4/12CH4 and CH3D/ CH4 isotope ratio measurements of CH4. Moving the instrument out of the lab and into the field will significantly improve the spatial and temporal resolution of data and enhance the study of plant-soil-atmosphere CH4 source and sink processes. Our instrument is a Near-IR (1280-1340 nm) tunable diode laser Cavity Ringdown Spectroscopy (CRDS) system. CRDS is a technique in which the laser injects energy into a high finesse cavity by tuning to one of the cavity resonant modes, resulting in a buildup of energy. At some threshold intra-cavity intensity the injection is stopped, and the intensity decays exponentially due to losses such as absorption by molecules. If the laser is tuned to an absorption line of a sample gas, the concentration of the molecule is proportional to the decay constant (according to the Beer-Lambert law)--scanning over a frequency range produces an absorption spectrum. Currently our system has a resolution of 150 MHz scanning over a 30 GHz (0.2 nm) region, allowing us to resolve peaks at pressures of 100 torr. Using combinations of CH4 standard (natural isotopic abundance) and a 99% pure 13CH4 standard, we identified several lines in the CH4 HITRAN Database that we attribute to 13CH4. We use these and 12CH4 lines within the same region to measure 13CH4 concentration, 12CH4 concentration, and the isotope ratio (13C/12C and D/H). We present our lab-based prototype system, including our latest isotope ratio performance and measurement precision. In addition, we present the way forward to achieve both our target precision and portability.

  7. Gauging Skills of Hospital Security Personnel: a Statistically-driven, Questionnaire-based Approach.

    PubMed

    Rinkoo, Arvind Vashishta; Mishra, Shubhra; Rahesuddin; Nabi, Tauqeer; Chandra, Vidha; Chandra, Hem

    2013-01-01

    This study aims to gauge the technical and soft skills of the hospital security personnel so as to enable prioritization of their training needs. A cross sectional questionnaire based study was conducted in December 2011. Two separate predesigned and pretested questionnaires were used for gauging soft skills and technical skills of the security personnel. Extensive statistical analysis, including Multivariate Analysis (Pillai-Bartlett trace along with Multi-factorial ANOVA) and Post-hoc Tests (Bonferroni Test) was applied. The 143 participants performed better on the soft skills front with an average score of 6.43 and standard deviation of 1.40. The average technical skills score was 5.09 with a standard deviation of 1.44. The study avowed a need for formal hands on training with greater emphasis on technical skills. Multivariate analysis of the available data further helped in identifying 20 security personnel who should be prioritized for soft skills training and a group of 36 security personnel who should receive maximum attention during technical skills training. This statistically driven approach can be used as a prototype by healthcare delivery institutions worldwide, after situation specific customizations, to identify the training needs of any category of healthcare staff.

  8. Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets

    PubMed Central

    Bhikha, Charita; Andreasen, Arne; Christensen, Erik I.; Letts, Robyn F. R.; Pantanowitz, Adam; Rubin, David M.; Thomsen, Jesper S.; Zhai, Xiao-Yue

    2015-01-01

    An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron. PMID:26170896

  9. Gauging Skills of Hospital Security Personnel: a Statistically-driven, Questionnaire-based Approach

    PubMed Central

    Rinkoo, Arvind Vashishta; Mishra, Shubhra; Rahesuddin; Nabi, Tauqeer; Chandra, Vidha; Chandra, Hem

    2013-01-01

    Objectives This study aims to gauge the technical and soft skills of the hospital security personnel so as to enable prioritization of their training needs. Methodology A cross sectional questionnaire based study was conducted in December 2011. Two separate predesigned and pretested questionnaires were used for gauging soft skills and technical skills of the security personnel. Extensive statistical analysis, including Multivariate Analysis (Pillai-Bartlett trace along with Multi-factorial ANOVA) and Post-hoc Tests (Bonferroni Test) was applied. Results The 143 participants performed better on the soft skills front with an average score of 6.43 and standard deviation of 1.40. The average technical skills score was 5.09 with a standard deviation of 1.44. The study avowed a need for formal hands on training with greater emphasis on technical skills. Multivariate analysis of the available data further helped in identifying 20 security personnel who should be prioritized for soft skills training and a group of 36 security personnel who should receive maximum attention during technical skills training. Conclusion This statistically driven approach can be used as a prototype by healthcare delivery institutions worldwide, after situation specific customizations, to identify the training needs of any category of healthcare staff. PMID:23559904

  10. Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets.

    PubMed

    Bhikha, Charita; Andreasen, Arne; Christensen, Erik I; Letts, Robyn F R; Pantanowitz, Adam; Rubin, David M; Thomsen, Jesper S; Zhai, Xiao-Yue

    2015-01-01

    An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron.

  11. Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Eric; Teng, Chu; van Kessel, Theodore

    We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) formore » initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.« less

  12. NPS and Online WOM: Investigating the Relationship Between Customers' Promoter Scores and eWOM Behavior.

    PubMed

    Raassens, Néomie; Haans, Hans

    2017-08-01

    The Net Promoter Score (NPS) is, according to Reichheld, the single most reliable indicator of company growth, and many companies use this recommendation-based technique for measuring customer loyalty. Despite its widespread adoption by many companies across multiple industries, the debate about NPS goes on. A major concern is that managers treat NPS as being equivalent across customers, which is often very misleading. By using a unique data set that combines customers' promoter scores and online word-of-mouth (eWOM) behavior, this research studies how individual customers' promoter scores are related to eWOM, including its relationship with the three categories of customers that are identified by the NPS paradigm (i.e., promoters, passives, and detractors). Based on a sample of 189 customers, their promoter scores and corresponding eWOM, the results show that there is a positive relationship between customers' promoter scores and the valence of online messages. Further, while detractors and promoters are homogeneous with respect to the valence of the eWOM messages they spread, passives show message valence heterogeneity. Thus, although passives, the largest group of customers, have no weight in calculating the NPS, our results reveal that companies should flag passives for further attention and action.

  13. Customer Satisfaction with Public Libraries.

    ERIC Educational Resources Information Center

    D'Elia, George; Rodger, Eleanor Jo

    1996-01-01

    Surveys conducted in 142 urban public libraries examined customer satisfaction, comparisons with other libraries, and factors affecting satisfaction. Overall, customers were satisfied with their libraries but experienced different levels of satisfaction based on convenience, availability of materials and information, and services facilitating…

  14. Characterization of a customized calibration unit for continuous measurements of the isotopic composition of water vapor

    NASA Astrophysics Data System (ADS)

    Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara

    2017-04-01

    The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.

  15. Does employee safety influence customer satisfaction? Evidence from the electric utility industry.

    PubMed

    Willis, P Geoffrey; Brown, Karen A; Prussia, Gregory E

    2012-12-01

    Research on workplace safety has not examined implications for business performance outcomes such as customer satisfaction. In a U.S. electric utility company, we surveyed 821 employees in 20 work groups, and also had access to archival safety data and the results of a customer satisfaction survey (n=341). In geographically-based work units where there were more employee injuries (based on archival records), customers were less satisfied with the service they received. Safety climate, mediated by safety citizenship behaviors (SCBs), added to the predictive power of the group-level model, but these two constructs exerted their influence independently from actual injuries. In combination, two safety-related predictor paths (injuries and climate/SCB) explained 53% of the variance in customer satisfaction. Results offer preliminary evidence that workplace safety influences customer satisfaction, suggesting that there are likely spillover effects between the safety environment and the service environment. Additional research will be needed to assess the specific mechanisms that convert employee injuries into palpable results for customers. Better safety climate and reductions in employee injuries have the potential to offer payoffs in terms of what customers experience. Copyright © 2012 National Safety Council and Elsevier Ltd. All rights reserved.

  16. Case study: the Health SmartLibrary* experiences in web personalization and customization at the Galter Health Sciences Library, Northwestern University

    PubMed Central

    Shedlock, James; Frisque, Michelle; Hunt, Steve; Walton, Linda; Handler, Jonathan; Gillam, Michael

    2010-01-01

    Question: How can the user's access to health information, especially full-text articles, be improved? The solution is building and evaluating the Health SmartLibrary (HSL). Setting: The setting is the Galter Health Sciences Library, Feinberg School of Medicine, Northwestern University. Method: The HSL was built on web-based personalization and customization tools: My E-Resources, Stay Current, Quick Search, and File Cabinet. Personalization and customization data were tracked to show user activity with these value-added, online services. Main Results: Registration data indicated that users were receptive to personalized resource selection and that the automated application of specialty-based, personalized HSLs was more frequently adopted than manual customization by users. Those who did customize customized My E-Resources and Stay Current more often than Quick Search and File Cabinet. Most of those who customized did so only once. Conclusion: Users did not always take advantage of the services designed to aid their library research experiences. When personalization is available at registration, users readily accepted it. Customization tools were used less frequently; however, more research is needed to determine why this was the case. PMID:20428276

  17. System and method for deriving a process-based specification

    NASA Technical Reports Server (NTRS)

    Hinchey, Michael Gerard (Inventor); Rouff, Christopher A. (Inventor); Rash, James Larry (Inventor)

    2009-01-01

    A system and method for deriving a process-based specification for a system is disclosed. The process-based specification is mathematically inferred from a trace-based specification. The trace-based specification is derived from a non-empty set of traces or natural language scenarios. The process-based specification is mathematically equivalent to the trace-based specification. Code is generated, if applicable, from the process-based specification. A process, or phases of a process, using the features disclosed can be reversed and repeated to allow for an interactive development and modification of legacy systems. The process is applicable to any class of system, including, but not limited to, biological and physical systems, electrical and electro-mechanical systems in addition to software, hardware and hybrid hardware-software systems.

  18. Research on CPFR pattern of the Internet of things based on B2C

    NASA Astrophysics Data System (ADS)

    Zhou, Ling; Yang, Jie

    2013-03-01

    The CPFR pattern proposed by this article is based on the internet of things platform, using frontier technology of internet of things to realize real-time monitoring and the feedback in logistics, information stream in B2C mode, and simultaneously construct an e-business mode which takes the customer guidance as the center to be possible to meet the customers' need and realize the service made by customer. This new pattern uses the coordination, plan, prediction and replenishment of CPFR to realize custom-made stock based on B2C for terminal customer and specialized service for commodity stock. Moreover, it can bring suppliers real-time monitoring of terminal logistics, storage and users' notes for use, and feed back users' bugs, adjustment of orders and plan of replenishment. Furthermore, based on new pattern, we can data min users' interests and undertake a study in increment modeling, process reengineering in enterprise, optimizing enterprise's interior resources and conformity industry of supply chain. Above all it provides a new mentality and the operation pattern for the electronic commerce marketing.

  19. Image feature based GPS trace filtering for road network generation and road segmentation

    DOE PAGES

    Yuan, Jiangye; Cheriyadat, Anil M.

    2015-10-19

    We propose a new method to infer road networks from GPS trace data and accurately segment road regions in high-resolution aerial images. Unlike previous efforts that rely on GPS traces alone, we exploit image features to infer road networks from noisy trace data. The inferred road network is used to guide road segmentation. We show that the number of image segments spanned by the traces and the trace orientation validated with image features are important attributes for identifying GPS traces on road regions. Based on filtered traces , we construct road networks and integrate them with image features to segmentmore » road regions. Lastly, our experiments show that the proposed method produces more accurate road networks than the leading method that uses GPS traces alone, and also achieves high accuracy in segmenting road regions even with very noisy GPS data.« less

  20. Image feature based GPS trace filtering for road network generation and road segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Jiangye; Cheriyadat, Anil M.

    We propose a new method to infer road networks from GPS trace data and accurately segment road regions in high-resolution aerial images. Unlike previous efforts that rely on GPS traces alone, we exploit image features to infer road networks from noisy trace data. The inferred road network is used to guide road segmentation. We show that the number of image segments spanned by the traces and the trace orientation validated with image features are important attributes for identifying GPS traces on road regions. Based on filtered traces , we construct road networks and integrate them with image features to segmentmore » road regions. Lastly, our experiments show that the proposed method produces more accurate road networks than the leading method that uses GPS traces alone, and also achieves high accuracy in segmenting road regions even with very noisy GPS data.« less

  1. Environmental factors controlling transient and seasonal changes of trace gases within shallow vadose zone

    NASA Astrophysics Data System (ADS)

    Pla, Concepcion; Galiana-Merino, Juan Jose; Cuezva, Soledad; Fernandez-Cortes, Angel; Garcia-Anton, Elena; Cuevas, Jaime; Cañaveras, Juan Carlos; Sanchez-Moral, Sergio; Benavente, David

    2014-05-01

    Shallow vadose environments below soil, mainly caves, show significant seasonal and even daily variations in gas composition of ground air, which involves the exchange of large amounts of gases, e.g. greenhouse gases (GHGs) as CO2 or CH4, with the lower troposphere. To understand better the role of caves as a sink or depot of GHGs, geochemical tracing of air (atmosphere, soil and ground air) was performed at Rull cave (southeast Spain) by monitoring CH4, CO2 and the stable carbon isotopic delta13C[CO2] using cavity ring-down spectroscopy (CRDS). A comprehensive microclimatic monitoring of exterior and cave atmosphere was simultaneously conducted to GHGs-tracking, including factors as temperature, barometric pressure, relative humidity and concentration of CO2 and 222Rn. The analysis of the measured data allows understanding outgassing and isolation processes taking place in the karst cavity. Annual patterns of gases behaviour can be distinguished, depending on the prevailing relationship between outer atmosphere, indoor atmosphere and soil system. Cave air temperature fluctuates around 15.7 ºC and relative humidity remains higher than 96% the whole annual cycle. The mean concentration of 222Rn is 1584 Bq m-3 while CO2 remains 1921 ppm. When external temperature is higher of indoor temperature (April-October), the highest levels of both trace gases are reached, while levels drop to its lowest values in the coldest months. Preliminary results obtained show an annual variation in concentration of CO2 inside the cave between 3300 ppm and 900 ppm, whereas corresponding isotopic signal delta13CO2 varies between -24‰ and -21‰. The results have been studied by Keeling model that approximates the isotopic signal of the source contribution in a resulting air mix. The values registered inside the cave were represented joined to results for exterior air (average values round 410 ppm of CO2 and -9 ‰ for delta13C). Value obtained is -27‰ pointing to a high influence of the soil produced CO2 (with a characteristic signal of -27‰ for C3 plants) in the cave atmosphere. The lowest levels of CO2 coincide with the highest of delta13C pointing to an input of exterior air during the degassing stage. Regarding the CH4 concentration inside the cave, higher values (0.3 ppm average concentration) are observed during outgassing stage than the isolation period (CH4 mean value of 0 ppm), confirming a major connection with the exterior atmosphere (average value of methane 1.8 ppm) during outgassing stage. By introducing wavelet analysis on obtained time series filtered signal of raw data show strong dependencies between trace gases and studied parameters. For instance, values of coherence between relative humidity and CO2 or 222Rn concentration are higher than 0.9. Results show that gas patterns dependence on relative humidity, atmospheric pressure and temperatures (indoor and outdoor) prevails throughout a year, determining the outgassing and isolation periods identified by statistical analyses. The measured of delta13C and CH4 concentration became a useful tool to understand processes affecting cave air and driving parameters variations inside the cave. Moreover, combining wavelet analysis, statistics and resemblance techniques, seasonal and transient behaviour of gases exchange can be highlighted in subterranean sites as Rull Cave.

  2. Transport and Chemical Evolution over the Pacific (TRACE-P) aircraft mission: Design, execution, and first results

    NASA Astrophysics Data System (ADS)

    Jacob, Daniel J.; Crawford, James H.; Kleb, Mary M.; Connors, Vickie S.; Bendura, Richard J.; Raper, James L.; Sachse, Glen W.; Gille, John C.; Emmons, Louisa; Heald, Colette L.

    2003-10-01

    The NASA Transport and Chemical Evolution over the Pacific (TRACE-P) aircraft mission was conducted in February-April 2001 over the NW Pacific (1) to characterize the Asian chemical outflow and relate it quantitatively to its sources and (2) to determine its chemical evolution. It used two aircraft, a DC-8 and a P-3B, operating out of Hong Kong and Yokota Air Force Base (near Tokyo), with secondary sites in Hawaii, Wake Island, Guam, Okinawa, and Midway. The aircraft carried instrumentation for measurements of long-lived greenhouse gases, ozone and its precursors, aerosols and their precursors, related species, and chemical tracers. Five chemical transport models (CTMs) were used for chemical forecasting. Customized bottom-up emission inventories for East Asia were generated prior to the mission to support chemical forecasting and to serve as a priori for evaluation with the aircraft data. Validation flights were conducted for the Measurements Of Pollution In The Troposphere (MOPITT) satellite instrument and revealed little bias (6 ± 2%) in the MOPITT measurements of CO columns. A major event of transpacific Asian pollution was characterized through combined analysis of TRACE-P and MOPITT data. The TRACE-P observations showed that cold fronts sweeping across East Asia and the associated warm conveyor belts (WCBs) are the dominant pathway for Asian outflow to the Pacific in spring. The WCBs lift both anthropogenic and biomass burning (SE Asia) effluents to the free troposphere, resulting in complex chemical signatures. The TRACE-P data are in general consistent with a priori emission inventories, lending confidence in our ability to quantify Asian emissions from socioeconomic data and emission factors. However, the residential combustion source in rural China was found to be much larger than the a priori, and there were also unexplained chemical enhancements (HCN, CH3Cl, OCS, alkylnitrates) in Chinese urban plumes. The Asian source of CCl4 was found to be much higher than government estimates. Measurements of HCN and CH3CN indicated a dominant biomass burning source and ocean sink for both gases. Large fractions of sulfate and nitrate were found to be present in dust aerosols. Photochemical activity in the Asian outflow was strongly reduced by aerosol attenuation of UV radiation, with major implications for the concentrations of HOx radicals. New particle formation, apparently from ternary nucleation involving NH3, was observed in Chinese urban plumes.

  3. Transport and Chemical Evolution over the Pacific (TRACE-P)Aircraft Mission: Design, Execution, and First Results

    NASA Technical Reports Server (NTRS)

    Jacob, Daniel J.; Crawford, James H.; Kleb, Mary M.; Connors, Vickie S.; Bendura, Richard J.; Raper, James L.; Sachse, Glen W.; Gille, John C.; Emmons, Louisa; Heald, Colette L.

    2003-01-01

    The NASA Transport and Chemical Evolution over the Pacific (TRACE-P) aircraft mission was conducted in February-April 2001 over the NW Pacific (1) to characterize the Asian chemical outflow and relate it quantitatively to its sources and (2) to determine its chemical evolution. It used two aircraft, a DC-8 and a P-3B, operating out of Hong Kong and Yokota Air Force Base (near Tokyo), with secondary sites in Hawaii, Wake Island, Guam, Okinawa, and Midway. The aircraft carried instrumentation for measurements of long-lived greenhouse gases, ozone and its precursors, aerosols and their precursors, related species, and chemical tracers. Five chemical transport models (CTMs) were used for chemical forecasting. Customized bottom-up emission inventories for East Asia were generated prior to the mission to support chemical forecasting and to serve as a priori for evaluation with the aircraft data. Validation flights were conducted for the Measurements Of Pollution In The Troposphere (MOPITT) satellite instrument and revealed little bias (6 plus or minus 2%) in the MOPITT measurements of CO columns. A major event of transpacific Asian pollution was characterized through combined analysis of TRACE-P and MOPITT data. The TRACE-P observations showed that cold fronts sweeping across East Asia and the associated warm conveyor belts (WCBs) are the dominant pathway for Asian outflow to the Pacific in spring. The WCBs lift both anthropogenic and biomass burning (SE Asia) effluents to the free troposphere, resulting in complex chemical signatures. The TRACE-P data are in general consistent with a priori emission inventories, lending confidence in our ability to quantify Asian emissions from socioeconomic data and emission factors. However, the residential combustion source in rural China was found to be much larger than the a priori, and there were also unexplained chemical enhancements (HCN, CH3Cl, OCS, alkylnitrates) in Chinese urban plumes. The Asian source of CCl4 was found to be much higher than government estimates. Measurements of HCN and CH3CN indicated a dominant biomass burning source and ocean sink for both gases. Large fractions of sulfate and nitrate were found to be present in dust aerosols. Photochemical activity in the Asian outflow was strongly reduced by aerosol attenuation of UV radiation, with major implications for the concentrations of HOx, radicals. New particle formation, apparently from ternary nucleation involving NH3, was observed in Chinese urban plumes.

  4. Employee customer orientation in manufacturing organizations: joint influences of customer proximity and the senior leadership team.

    PubMed

    Liao, Hui; Subramony, Mahesh

    2008-03-01

    Pursuing a customer-focused strategy in manufacturing organizations requires employees across functions to embrace the importance of understanding customer needs and to align their everyday efforts with the goal of satisfying and retaining customers. Little prior research has examined what factors influence employee customer orientation in manufacturing settings. Drawing on the attraction-selection-attrition model, upper-echelons theory, and contingency theories of leadership, this study investigated the joint influences of functional roles' proximity to external customers and the senior leadership team's customer orientation on employee customer orientation. Hierarchical linear modeling results based on data obtained from 4,299 employees and 403 senior leaders from 42 facilities of a global manufacturer operating in 16 countries revealed that employees occupying customer-contact roles had the highest level of customer orientation, followed by employees occupying production roles, and then by those in support roles. In addition, there was a positive relationship between the senior leadership team's customer orientation and employee customer orientation for all 3 functional roles. The positive relationship between the senior leadership team and employee customer orientation was the strongest for employees in support roles, suggesting that lower levels of proximity to external customers may create a greater need for leadership in developing employees' customer-oriented attitudes. Copyright 2008 APA

  5. I want products my own way, but which way? The effects of different product categories and cues on customer responses to Web-based customizations.

    PubMed

    Chang, Chia-Chi; Chen, Hui-Yun

    2009-02-01

    Mass customization is a strategy that has been adopted by companies to tailor their products in order to match customer needs more precisely. Therefore, to fully capture the value of mass customization, it is crucial to explore how customers react to mass customization. In previous studies, an implied premise has been that consumers are keen to embrace customized products, and this assumption has also been treated by firms as a prerequisite for successful mass customization strategies. However, an undesirable complexity may result from difficult configuration processes that may intimidate and confuse some customers. Hence, this study explores strategies that marketers can employ to facilitate the customization process. Specifically, this study investigates how to enhance customer satisfaction and purchase decision toward customized products by providing cues compatible with the product category. It is hypothesized that for search products, customers rely more on intrinsic cues when making configuration decisions. On the other hand, for experience products, customers perceive extrinsic cues to be more valuable in assisting them to make configuration decisions. The results suggest that consumers tend to respond more favorably toward customized search products when intrinsic cues are provided than when extrinsic or irrelevant ones are provided. In contrast, when customizing experience products, customers tend to depend more on extrinsic cues than on intrinsic or irrelevant ones.

  6. A Customized Transportation Intervention for Persons with Visual Impairments

    ERIC Educational Resources Information Center

    Crudden, Adele; Antonelli, Karla; O'Mally, Jamie

    2017-01-01

    Introduction: Transportation can be an employment barrier for persons with disabilities, particularly those with visual impairments. A customized transportation intervention for people with visual impairments, based on concepts associated with customized employment, was devised, implemented, and evaluated. Methods: A pretest and posttest…

  7. Reinventing the International Space Station Payload Integration Processes and Capabilities

    NASA Technical Reports Server (NTRS)

    Jones, Rod; Price, Carmen; Copeland, Scott; Geiger, Wade; Geiger, Wade; Rice, Amanda; Lauchner, Adam

    2011-01-01

    The fundamental ISS payload integration philosophy, processes and capabilities were established in the context of how NASA science programs were conducted and executed in the early 1990 s. Today, with the designation of the United States (US) portion of ISS as a National Lab, the ISS payload customer base is growing to include other government agencies, private and commercial research. The fields of research are becoming more diverse expanding from the NASA centric physical, materials and human research sciences to test beds for exploration and technology demonstration, biology and biotechnology, and as an Earth and Space science platform. This new customer base has a broader more diverse set of expectations and requirements for payload design, verification, integration, test, training, and operations. One size fits all processes are not responsive to this broader customer base. To maintain an organization s effectiveness it must listen to its customers, understand their needs, learn from its mistakes, and foster an environment of continual process improvement. The ISS Payloads office is evolving to meet these new customer expectations.

  8. Estimating the Benefits of the Air Force Purchasing and Supply Chain Management Initiative

    DTIC Science & Technology

    2008-01-01

    sector, known as strategic sourcing.6 The Customer Relationship Management initiative ( CRM ) pro- vides a single customer point of contact for all... Customer Relationship Management initiative. commodity council A term used to describe a cross-functional sourc- ing group charged with formulating a...initiative has four major components, all based on commercial best practices (Gabreski, 2004): commodity councils customer relationship management

  9. American Recovery and Reinvestment Act of 2009. Experiences from the Consumer Behavior Studies on Engaging Customers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappers, Peter; Scheer, Richard

    2014-09-01

    One of the most important aspects for the successful implementation of customer-facing programs is to better understand how to engage and communicate with consumers. Customer-facing programs include time-based rates, information and feedback, load management, and energy efficiency. This report presents lessons learned by utilities through consumer behavior studies (CBS) conducted as part of the Department of Energy’s (DOE) Smart Grid Investment Grant (SGIG) program. The SGIG CBS effort presents a unique opportunity to advance the understanding of consumer behaviors in terms of customer acceptance and retention, and electricity consumption and peak demand impacts. The effort includes eleven comprehensive studies withmore » the aim of evaluating the response of residential and small commercial customers to time-based rate programs implemented in conjunction with advanced metering infrastructure and customer systems such as in-home displays, programmable communicating thermostats, and web portals. DOE set guidelines and protocols that sought to help the utilities design studies that would rigorously test and more precisely estimate the impact of time-based rates on customers’ energy usage patterns, as well as identify the key drivers that motivate behavioral changes.« less

  10. A store-based intervention to increase fruit and vegetable consumption: The El Valor de Nuestra Salud cluster randomized controlled trial.

    PubMed

    Ayala, Guadalupe X; Baquero, Barbara; Pickrel, Julie L; Mayer, Joni; Belch, George; Rock, Cheryl L; Linnan, Laura; Gittelsohn, Joel; Sanchez-Flack, Jennifer; Elder, John P

    2015-05-01

    Most evidence-based interventions to improve fruit and vegetable (FV) consumption target individual behaviors and family systems; however, these changes are difficult to sustain without environmental support. This paper describes an innovative social and structural food store-based intervention to increase availability and accessibility of FVs in tiendas (small- to medium-sized Latino food stores) and purchasing and consumption of FVs among tienda customers. Using a cluster randomized controlled trial with 16 tiendas pair-matched and randomized to an intervention or wait-list control condition, this study will evaluate a 2-month intervention directed at tiendas, managers, and employees followed by a 4-month customer-directed food marketing campaign. The intervention involves social (e.g., employee trainings) and structural (e.g., infrastructure) environmental changes. Three hundred sixty-nine customers (approximately 23 per tienda) serve on an evaluation cohort and complete assessments (interviews and measurements of weight) at 3 time points: baseline, 6-months post-baseline, and 12-months post-baseline. The primary study outcome is customer-reported daily consumption of FVs. Manager interviews and monthly tienda audits and collection of sales data will provide evidence of tienda-level intervention effects, our secondary outcomes. Process evaluation methods assess dose delivered, dose received, and fidelity. Recruitment of tiendas, managers, employees, and customers is complete. Demographic data shows that 30% of the customers are males, thus providing a unique opportunity to examine the effects of a tienda-based intervention on Latino men. Determining whether a tienda-based intervention can improve customers' FV purchasing and consumption will provide key evidence for how to create healthier consumer food environments. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Association between pregnancy complications and small-for-gestational-age birth weight defined by customized fetal growth standard versus a population-based standard.

    PubMed

    Odibo, Anthony O; Francis, Andre; Cahill, Alison G; Macones, George A; Crane, James P; Gardosi, Jason

    2011-03-01

    To derive coefficients for developing a customized growth chart for a Mid-Western US population, and to estimate the association between pregnancy outcomes and smallness for gestational age (SGA) defined by the customized growth chart compared with a population-based growth chart for the USA. A retrospective cohort study of an ultrasound database using 54,433 pregnancies meeting inclusion criteria was conducted. Coefficients for customized centiles were derived using 42,277 pregnancies and compared with those obtained from other populations. Two adverse outcome indicators were defined (greater than 7 day stay in the neonatal unit and stillbirth [SB]), and the risk for each outcome was calculated for the groups of pregnancies defined as SGA by the population standard and SGA by the customized standard using 12,456 pregnancies for the validation sample. The growth potential expressed as weight at 40 weeks in this population was 3524 g (standard error: 402 g). In the validation population, 4055 cases of SGA were identified using both population and customized standards. The cases additionally identified as SGA by the customized method had a significantly increased risk of each of the adverse outcome categories. The sensitivity and specificity of those identified as SGA by customized method only for detecting pregnancies at risk for SB was 32.7% (95% confidence interval [CI] 27.0-38.8%) and 95.1% (95% CI: 94.7-95.0%) versus 0.8% (95% CI 0.1-2.7%) and 98.0% (95% CI 97.8-98.2%)for those identified by only the population-based method, respectively. SGA defined by customized growth potential is able to identify substantially more pregnancies at a risk for adverse outcome than the currently used national standard for fetal growth.

  12. American Recovery and Reinvestment Act of 2009: Final Report on Customer Acceptance, Retention, and Response to Time-Based Rates from Consumer Behavior Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappers, Peter; Scheer, Rich

    Time-based rate programs, enabled by utility investments in advanced metering infrastructure (AMI), are increasingly being considered by utilities as tools to reduce peak demand and enable customers to better manage consumption and costs. Under the Smart Grid Investment Grant Program (SGIG), the U.S. Department of Energy (DOE) partnered with several electric utilities to conduct consumer behavior studies (CBS). The goals involved applying randomized and controlled experimental designs for estimating customer responses more precisely and credibly to advance understanding of time-based rates and customer systems, and provide new information for improving program designs, implementation strategies, and evaluations. The intent was tomore » produce more robust and credible analysis of impacts, costs, benefits, and lessons learned and assist utility and regulatory decision makers in evaluating investment opportunities involving time-based rates.« less

  13. Electrical service reliability: the customer perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samsa, M.E.; Hub, K.A.; Krohm, G.C.

    1978-09-01

    Electric-utility-system reliability criteria have traditionally been established as a matter of utility policy or through long-term engineering practice, generally with no supportive customer cost/benefit analysis as justification. This report presents results of an initial study of the customer perspective toward electric-utility-system reliability, based on critical review of over 20 previous and ongoing efforts to quantify the customer's value of reliable electric service. A possible structure of customer classifications is suggested as a reasonable level of disaggregation for further investigation of customer value, and these groups are characterized in terms of their electricity use patterns. The values that customers assign tomore » reliability are discussed in terms of internal and external cost components. A list of options for effecting changes in customer service reliability is set forth, and some of the many policy issues that could alter customer-service reliability are identified.« less

  14. Classification of customer lifetime value models using Markov chain

    NASA Astrophysics Data System (ADS)

    Permana, Dony; Pasaribu, Udjianna S.; Indratno, Sapto W.; Suprayogi

    2017-10-01

    A firm’s potential reward in future time from a customer can be determined by customer lifetime value (CLV). There are some mathematic methods to calculate it. One method is using Markov chain stochastic model. Here, a customer is assumed through some states. Transition inter the states follow Markovian properties. If we are given some states for a customer and the relationships inter states, then we can make some Markov models to describe the properties of the customer. As Markov models, CLV is defined as a vector contains CLV for a customer in the first state. In this paper we make a classification of Markov Models to calculate CLV. Start from two states of customer model, we make develop in many states models. The development a model is based on weaknesses in previous model. Some last models can be expected to describe how real characters of customers in a firm.

  15. Analysis of air quality with numerical simulation (CMAQ), and observations of trace gases

    NASA Astrophysics Data System (ADS)

    Castellanos, Patricia

    Ozone, a secondary pollutant, is a strong oxidant that can pose a risk to human health. It is formed from a complex set of photochemical reactions involving nitrogen oxides (NOx) and volatile organic compounds (VOCs). Ambient measurements and air quality modeling of ozone and its precursors are important tools for support of regulatory decisions, and analyzing atmospheric chemical and physical processes. I worked on three methods to improve our understanding of photochemical ozone production in the Eastern U.S.: a new detector for NO2, a numerical experiment to test the sensitivity to the timing to emissions, and comparison of modeled and observed vertical profiles of CO and ozone. A small, commercially available cavity ring-down spectroscopy (CRDS) NO2 detector suitable for surface and aircraft monitoring was modified and characterized. The CRDS detector was run in parallel to an ozone chemiluminescence device with photolytic conversion of NO2 to NO. The two instruments measured ambient air in suburban Maryland. A linear least-squares fit to a direct comparison of the data resulted in a slope of 0.960+/-0.002 and R of 0.995, showing agreement between two measurement techniques within experimental uncertainty. The sensitivity of the Community Multiscale Air Quality (CMAQ) model to the temporal variation of four emissions sectors was investigated to understand the effect of emissions' daily variability on modeled ozone. Decreasing the variability of mobile source emissions changed the 8-hour maximum ozone concentration by +/-7 parts per billion by volume (ppbv). Increasing the variability of point source emissions affected ozone concentrations by +/-6 ppbv, but only in areas close to the source. CO is an ideal tracer for analyzing pollutant transport in AQMs because the atmospheric lifetime is longer than the timescale of boundary layer mixing. CO can be used as a tracer if model performance of CO is well understood. An evaluation of CO model performance in CMAQ was carried out using aircraft observations taken for the Regional Atmospheric Measurement, Modeling and Prediction Program (RAMMPP) in the summer of 2002. Comparison of modeled and observed CO total columns were generally in agreement within 5-10%. There is little evidence that the CO emissions inventory is grossly overestimated. CMAQ predicts the same vertical profile shape for all of the observations, i.e. CO is well mixed throughout the boundary layer. However, the majority of observations have poorly mixed air below 500 m, and well mixed air above. CMAQ appears to be transporting CO away from the surface more quickly than what is observed. Turbulent mixing in the model is represented with K-theory. A minimum Kz that scales with fractional urban land use is imposed in order to account for subgrid scale obstacles in urban areas and the urban heat island effect. Micrometeorological observations suggest that the minimum Kz is somewhat high. A sensitivity case where the minimum K z was reduced from 0.5 m2/s to 0.1 m2/s was carried out. Model performance of surface ozone observations at night increased significantly. The model better captures the observed ozone minimum with slower mixing, and increases ozone concentrations in the residual layer. Model performance of CO and ozone morning vertical profiles improves, but the effect is not large enough to bring the model and measurements into agreement. Comparison of modeled CO and O3 vertical profiles shows that turbulent mixing (as represented by eddy diffusivity) appears to be too fast, while convective mixing may be too slow.

  16. Mass Spectrometry in the Home and Garden

    NASA Astrophysics Data System (ADS)

    Pulliam, Christopher J.; Bain, Ryan M.; Wiley, Joshua S.; Ouyang, Zheng; Cooks, R. Graham

    2015-02-01

    Identification of active components in a variety of chemical products used directly by consumers is described at both trace and bulk levels using mass spectrometry. The combination of external ambient ionization with a portable mass spectrometer capable of tandem mass spectrometry provides high chemical specificity and sensitivity as well as allowing on-site monitoring. These experiments were done using a custom-built portable ion trap mass spectrometer in combination with the ambient ionization methods of paper spray, leaf spray, and low temperature plasma ionization. Bactericides, garden chemicals, air fresheners, and other products were examined. Herbicide applied to suburban lawns was detected in situ on single leaves 5 d after application.

  17. Quantization of collagen organization in the stroma with a new order coefficient

    PubMed Central

    Germann, James A.; Martinez-Enriquez, Eduardo; Marcos, Susana

    2017-01-01

    Many optical and biomechanical properties of the cornea, specifically the transparency of the stroma and its stiffness, can be traced to the degree of order and direction of the constituent collagen fibers. To measure the degree of order inside the cornea, a new metric, the order coefficient, was introduced to quantify the organization of the collagen fibers from images of the stroma produced with a custom-developed second harmonic generation microscope. The order coefficient method gave a quantitative assessment of the differences in stromal collagen arrangement across the cornea depths and between untreated stroma and cross-linked stroma. PMID:29359095

  18. TDRS-A - The pioneering payload

    NASA Technical Reports Server (NTRS)

    Browning, R. K.

    1983-01-01

    The first launch of a Tracking Data Relay Satellite (TDRS-A) on board the Shuttle Orbiter 'Challenger' of the Space Transportation System (STS) provided many pioneering events as a payload/user. The TDRS-A was launched as a payload of the STS as well as a payload of the Inertial Upper Stage (IUS) on April 4, 1983. This paper traces the payload processing flow of the TDRS-A from its arrival at the Kennedy Space Center (KSC), through its launch on Challenger and its trans-orbit flight on the IUS to geosynchronous orbit. The TDRS-A, as a customer/user of these launch systems, is examined and reviewed and lessons learned are noted.

  19. Do Peripheral Refraction and Aberration Profiles Vary with the Type of Myopia? - An Illustration Using a Ray-Tracing Approach

    PubMed Central

    Bakaraju, Ravi C.; Ehrmann, Klaus; Papas, Eric B.; Ho, Arthur

    2010-01-01

    Purpose Myopia is considered to be the most common refractive error occurring in children and young adults, around the world. Motivated to elucidate how the process of emmetropization is disrupted, potentially causing myopia and its progression, researchers have shown great interest in peripheral refraction. This study assessed the effect of the myopia type, either refractive or axial, on peripheral refraction and aberration profiles. Methods Using customized schematic eye models for myopia in a ray tracing algorithm, peripheral aberrations, including the refractive error, were calculated as a function of myopia type. Results In all the selected models, hyperopic shifts in the mean spherical equivalent (MSE) component were found whose magnitude seemed to be largely dependent on the field angle. The MSE profiles showed larger hyperopic shifts for the axial type of myopic models than the refractive ones and were evident in -4 and -6 D prescriptions. Additionally, greater levels of astigmatic component (J180) were also seen in axial-length-dependent models, while refractive models showed higher levels of spherical aberration and coma. Conclusion This study has indicated that myopic eyes with primarily an axial component may have a greater risk of progression than their refractive counterparts albeit with the same degree of refractive error. This prediction emerges from the presented theoretical ray tracing model and, therefore, requires clinical confirmation.

  20. Customizing Curriculum with Digital Resources

    ERIC Educational Resources Information Center

    Miller, Jeffrey

    2011-01-01

    To effectively use digital resources in the classroom, teachers must customize the information, merge it with pre-existing curriculum, differentiate it for diverse student populations, and still meet standards-based learning goals. This article describes a solution to these challenges: the Curriculum Customization Service, which provides access to…

  1. Cross-Cultural Perspectives of Service Quality and Risk in Air Transportation

    NASA Technical Reports Server (NTRS)

    Cunningham, Lawrence F.; Young, Clifford E.; Lee, Moonkyu

    2002-01-01

    This study compares US and Korean customers in terms of their perceptions of airline service quality based on SERVPERF and industry-based measures, as well as their perceptions of risks involved in the airline choice. SERVPERF is a set of multi-dimensional measures of customer evaluations of service quality. The results indicate that: (1) US passengers are generally more satisfied with their airline service than Korean customers on most of the SERVPERF dimensions; (2) Koreans are generally more satisfied with the bumping procedures whereas US participants feel more satisfied with the airline's baggage handling, operations/safety, and connections; and (3) US participants perceive higher levels of performance and financial risks whereas Koreans feel greater social risk in choosing an airline. This study also examines the SERVPERF, industry-based measure, and perceived risk in predicting customer satisfaction with, and intention to repatronize the airline. The results suggest that US customers consider service reliability, in-flight comfort, and connections as the key factors determining satisfaction with airline service whereas Korean passengers generally regard reliability, assurance, and risk factors as predictors of satisfaction. The determining factors of customer intention to repatronize the airline are reliability and empathy for US, and reliability and overall risk for Korean customers. The study demonstrates the applicability of SERVPERF as a cross-cultural tool and indicates the importance of perceived risk in cross-cultural studies.

  2. Building automatic customer complaints filtering application based on Twitter in Bahasa Indonesia

    NASA Astrophysics Data System (ADS)

    Gunawan, D.; Siregar, R. P.; Rahmat, R. F.; Amalia, A.

    2018-03-01

    Twitter has become a media to provide communication between a company with its customers. The average number of Twitter active users monthly is 330 million. A lot of companies realize the potential of Twitter to establish good relationship with their customers. Therefore, they usually have one official Twitter account to act as customer care division. In Indonesia, one of the company that utilizes the potential of Twitter to reach their customers is PT Telkom. PT Telkom has an official customer service account (called @TelkomCare) to receive customers’ problem. However, because of this account is open for public, Twitter users might post all kind of messages (not only complaints) to Telkom Care account. This leads to a problem that the Telkom Care account contains not only the customer complaints but also compliment and ordinary message. Furthermore, the complaints should be distributed to relevant division such as “Indihome”, “Telkomsel”, “UseeTV”, and “Telepon” based on the content of the message. This research built the application that automatically filter twitter post messages into several pre-defined categories (based on existing divisions) using Naïve Bayes algorithm. This research is done by collecting Twitter message, data cleaning, data pre-processing, training and testing data, and evaluate the classification result. This research yields 97% accuracy to classify Twitter message into the categories mentioned earlier.

  3. A Multi-Period Optimization Model for Service Providers Using Online Reservation Systems: An Application to Hotels.

    PubMed

    Xu, Ming; Jiao, Yan; Li, Xiaoming; Cao, Qingfeng; Wang, Xiaoyang

    2015-01-01

    This paper presents a multi-period optimization model for high margin and zero salvage products in online distribution channels with classifying customers based on number of products required. Taking hotel customers as an example, one is regular customers who reserve rooms for one day, and the other is long term stay (LTS) customers who reserve rooms for a number of days. LTS may guarantee a specific amount of demand and generate opportunity income for a certain number of periods, meanwhile with risk of punishment incurred by overselling. By developing an operational optimization model and exploring the effects of parameters on optimal decisions, we suggest that service providers should make decisions based on the types of customers, number of products required, and duration of multi-period to reduce the loss of reputation and obtain more profit; at the same time, multi-period buying customers should buy products early. Finally, the paper conducts a numerical experiment, and the results are consistent with prevailing situations.

  4. A Multi-Period Optimization Model for Service Providers Using Online Reservation Systems: An Application to Hotels

    PubMed Central

    Xu, Ming; Jiao, Yan; Li, Xiaoming; Cao, Qingfeng; Wang, Xiaoyang

    2015-01-01

    This paper presents a multi-period optimization model for high margin and zero salvage products in online distribution channels with classifying customers based on number of products required. Taking hotel customers as an example, one is regular customers who reserve rooms for one day, and the other is long term stay (LTS) customers who reserve rooms for a number of days. LTS may guarantee a specific amount of demand and generate opportunity income for a certain number of periods, meanwhile with risk of punishment incurred by overselling. By developing an operational optimization model and exploring the effects of parameters on optimal decisions, we suggest that service providers should make decisions based on the types of customers, number of products required, and duration of multi-period to reduce the loss of reputation and obtain more profit; at the same time, multi-period buying customers should buy products early. Finally, the paper conducts a numerical experiment, and the results are consistent with prevailing situations. PMID:26147663

  5. Application of text mining for customer evaluations in commercial banking

    NASA Astrophysics Data System (ADS)

    Tan, Jing; Du, Xiaojiang; Hao, Pengpeng; Wang, Yanbo J.

    2015-07-01

    Nowadays customer attrition is increasingly serious in commercial banks. To combat this problem roundly, mining customer evaluation texts is as important as mining customer structured data. In order to extract hidden information from customer evaluations, Textual Feature Selection, Classification and Association Rule Mining are necessary techniques. This paper presents all three techniques by using Chinese Word Segmentation, C5.0 and Apriori, and a set of experiments were run based on a collection of real textual data that includes 823 customer evaluations taken from a Chinese commercial bank. Results, consequent solutions, some advice for the commercial bank are given in this paper.

  6. Ray Tracing and Modal Methods for Modeling Radio Propagation in Tunnels With Rough Walls

    PubMed Central

    Zhou, Chenming

    2017-01-01

    At the ultrahigh frequencies common to portable radios, tunnels such as mine entries are often modeled by hollow dielectric waveguides. The roughness condition of the tunnel walls has an influence on radio propagation, and therefore should be taken into account when an accurate power prediction is needed. This paper investigates how wall roughness affects radio propagation in tunnels, and presents a unified ray tracing and modal method for modeling radio propagation in tunnels with rough walls. First, general analytical formulas for modeling the influence of the wall roughness are derived, based on the modal method and the ray tracing method, respectively. Second, the equivalence of the ray tracing and modal methods in the presence of wall roughnesses is mathematically proved, by showing that the ray tracing-based analytical formula can converge to the modal-based formula through the Poisson summation formula. The derivation and findings are verified by simulation results based on ray tracing and modal methods. PMID:28935995

  7. Parametric Trace Slicing

    NASA Technical Reports Server (NTRS)

    Rosu, Grigore (Inventor); Chen, Feng (Inventor); Chen, Guo-fang; Wu, Yamei; Meredith, Patrick O. (Inventor)

    2014-01-01

    A program trace is obtained and events of the program trace are traversed. For each event identified in traversing the program trace, a trace slice of which the identified event is a part is identified based on the parameter instance of the identified event. For each trace slice of which the identified event is a part, the identified event is added to an end of a record of the trace slice. These parametric trace slices can be used in a variety of different manners, such as for monitoring, mining, and predicting.

  8. Customer Churn Prediction for Broadband Internet Services

    NASA Astrophysics Data System (ADS)

    Huang, B. Q.; Kechadi, M.-T.; Buckley, B.

    Although churn prediction has been an area of research in the voice branch of telecommunications services, more focused studies on the huge growth area of Broadband Internet services are limited. Therefore, this paper presents a new set of features for broadband Internet customer churn prediction, based on Henley segments, the broadband usage, dial types, the spend of dial-up, line-information, bill and payment information, account information. Then the four prediction techniques (Logistic Regressions, Decision Trees, Multilayer Perceptron Neural Networks and Support Vector Machines) are applied in customer churn, based on the new features. Finally, the evaluation of new features and a comparative analysis of the predictors are made for broadband customer churn prediction. The experimental results show that the new features with these four modelling techniques are efficient for customer churn prediction in the broadband service field.

  9. The Development of a Total Quality Management Plan for David Grant USAF Medical Center Travis Air Force Base, California

    DTIC Science & Technology

    1991-12-01

    customer satisfaction (DOD, 1988). While the application of TQM in the manufacturing industry and the military acquisition system has been successful, the...improvement of products and services. The overriding objective of TOM is to increase customer satisfaction (DOD, 1988). While the application of TOM in the...25 Description of the Organization ................... 26 Internal Customers ..................... ....... 30 External Customers

  10. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  11. Trace Replay and Network Simulation Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acun, Bilge; Jain, Nikhil; Bhatele, Abhinav

    2015-03-23

    TraceR is a trace reply tool built upon the ROSS-based CODES simulation framework. TraceR can be used for predicting network performances and understanding network behavior by simulating messaging in High Performance Computing applications on interconnection networks.

  12. Trace Replay and Network Simulation Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, Nikhil; Bhatele, Abhinav; Acun, Bilge

    TraceR Is a trace replay tool built upon the ROSS-based CODES simulation framework. TraceR can be used for predicting network performance and understanding network behavior by simulating messaging In High Performance Computing applications on interconnection networks.

  13. 76 FR 9820 - Notice of Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ... . SUPPLEMENTARY INFORMATION: I. Abstract LaRC leadership desires to seek out customer feedback across all mission..., customers will have the option to provide their feedback via e-mail, Web-based survey, or phone conversation in accordance with their preference. III. Data Title: LaRC Customer Satisfaction Assessment OMB...

  14. The Use of Pro/Engineer CAD Software and Fishbowl Tool Kit in Ray-tracing Analysis

    NASA Technical Reports Server (NTRS)

    Nounu, Hatem N.; Kim, Myung-Hee Y.; Ponomarev, Artem L.; Cucinotta, Francis A.

    2009-01-01

    This document is designed as a manual for a user who wants to operate the Pro/ENGINEER (ProE) Wildfire 3.0 with the NASA Space Radiation Program's (SRP) custom-designed Toolkit, called 'Fishbowl', for the ray tracing of complex spacecraft geometries given by a ProE CAD model. The analysis of spacecraft geometry through ray tracing is a vital part in the calculation of health risks from space radiation. Space radiation poses severe risks of cancer, degenerative diseases and acute radiation sickness during long-term exploration missions, and shielding optimization is an important component in the application of radiation risk models. Ray tracing is a technique in which 3-dimensional (3D) vehicle geometry can be represented as the input for the space radiation transport code and subsequent risk calculations. In ray tracing a certain number of rays (on the order of 1000) are used to calculate the equivalent thickness, say of aluminum, of the spacecraft geometry seen at a point of interest called the dose point. The rays originate at the dose point and terminate at a homogenously distributed set of points lying on a sphere that circumscribes the spacecraft and that has its center at the dose point. The distance a ray traverses in each material is converted to aluminum or other user-selected equivalent thickness. Then all equivalent thicknesses are summed up for each ray. Since each ray points to a direction, the aluminum equivalent of each ray represents the shielding that the geometry provides to the dose point from that particular direction. This manual will first list for the user the contact information for help in installing ProE and Fishbowl in addition to notes on the platform support and system requirements information. Second, the document will show the user how to use the software to ray trace a Pro/E-designed 3-D assembly and will serve later as a reference for troubleshooting. The user is assumed to have previous knowledge of ProE and CAD modeling.

  15. Enhanced Product Generation at NASA Data Centers Through Grid Technology

    NASA Technical Reports Server (NTRS)

    Barkstrom, Bruce R.; Hinke, Thomas H.; Gavali, Shradha; Seufzer, William J.

    2003-01-01

    This paper describes how grid technology can support the ability of NASA data centers to provide customized data products. A combination of grid technology and commodity processors are proposed to provide the bandwidth necessary to perform customized processing of data, with customized data subsetting providing the initial example. This customized subsetting engine can be used to support a new type of subsetting, called phenomena-based subsetting, where data is subsetted based on its association with some phenomena, such as mesoscale convective systems or hurricanes. This concept is expanded to allow the phenomena to be detected in one type of data, with the subsetting requirements transmitted to the subsetting engine to subset a different type of data. The subsetting requirements are generated by a data mining system and transmitted to the subsetter in the form of an XML feature index that describes the spatial and temporal extent of the phenomena. For this work, a grid-based mining system called the Grid Miner is used to identify the phenomena and generate the feature index. This paper discusses the value of grid technology in facilitating the development of a high performance customized product processing and the coupling of a grid mining system to support phenomena-based subsetting.

  16. Are Students Customers in Finnish Higher Education?

    ERIC Educational Resources Information Center

    Vuori, Johanna

    2013-01-01

    This study examines Finnish higher education students' perceptions of whether students are customers, based on qualitative interview data. The article contributes to the discussion on students as customers by giving attention to students' own voices from a country where tuition fees are not generally collected. The data are presented and analysed…

  17. 14 CFR 1214.107 - Postponement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Space Shuttle Flights of Payloads for Non-U.S. Government, Reimbursable Customers § 1214.107...) A customer postponing the flight of a payload will pay a postponement fee to NASA. The fee will be computed as a percentage of the customer's Shuttle standard flight price and will be based on the table...

  18. 14 CFR 1214.107 - Postponement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Space Shuttle Flights of Payloads for Non-U.S. Government, Reimbursable Customers § 1214.107...) A customer postponing the flight of a payload will pay a postponement fee to NASA. The fee will be computed as a percentage of the customer's Shuttle standard flight price and will be based on the table...

  19. 14 CFR 1214.107 - Postponement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Space Shuttle Flights of Payloads for Non-U.S. Government, Reimbursable Customers § 1214.107...) A customer postponing the flight of a payload will pay a postponement fee to NASA. The fee will be computed as a percentage of the customer's Shuttle standard flight price and will be based on the table...

  20. 14 CFR 1214.107 - Postponement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Space Shuttle Flights of Payloads for Non-U.S. Government, Reimbursable Customers § 1214.107...) A customer postponing the flight of a payload will pay a postponement fee to NASA. The fee will be computed as a percentage of the customer's Shuttle standard flight price and will be based on the table...

  1. 17 CFR 300.400 - Satisfaction of customer claims for standardized options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Satisfaction of customer... CORPORATION Closeout Or Completion of Open Contractual Commitments § 300.400 Satisfaction of customer claims... direct payment procedure pursuant to section 10 of the Act, in satisfaction of a claim based upon...

  2. A vigorous approach to customer service.

    PubMed

    Pollock, E K

    1993-01-01

    PPG Industries, Inc. is the world's largest supplier of automotive original coatings. Its business-to-business customers require individualized service based on specific requirements. The company has solidified these relationships by establishing satellite supply facilities, applying the quality process to problem solving, and providing a variety of outlets for customer feedback.

  3. Trace-Based Microanalytic Measurement of Self-Regulated Learning Processes

    ERIC Educational Resources Information Center

    Siadaty, Melody; Gaševic, Dragan; Hatala, Marek

    2016-01-01

    To keep pace with today's rapidly growing knowledge-driven society, productive self-regulation of one's learning processes are essential. We introduce and discuss a trace-based measurement protocol to measure the effects of scaffolding interventions on self-regulated learning (SRL) processes. It guides tracing of learners' actions in a learning…

  4. Empirical research on Kano’s model and customer satisfaction

    PubMed Central

    Lin, Feng-Han; Tsai, Sang-Bing; Lee, Yu-Cheng; Hsiao, Cheng-Fu; Zhou, Jie; Wang, Jiangtao; Shang, Zhiwen

    2017-01-01

    Products are now developed based on what customers desire, and thus attractive quality creation has become crucial. In studies on customer satisfaction, methods for analyzing quality attributes and enhancing customer satisfaction have been proposed to facilitate product development. Although substantial studies have performed to assess the impact of the attributes on customer satisfaction, little research has been conducted that quantitatively calculate the odds of customer satisfaction for the Kano classification, fitting a nonlinear relationship between attribute-level performance and customer satisfaction. In the present study, the odds of customer satisfaction were determined to identify the classification of quality attributes, and took customer psychology into account to suggest how decision-makers should prioritize the allocation of resources. A novel method for quantitatively assessing quality attributes was proposed to determine classification criteria and fit the nonlinear relationship between quality attributes and customer satisfaction. Subsequently, a case study was conducted on bicycle user satisfaction to verify the novel method. The concept of customer satisfaction odds was integrated with the value function from prospect theory to understand quality attributes. The results of this study can serve as a reference for product designers to create attractive quality attributes in their products and thus enhance customer satisfaction. PMID:28873418

  5. Empirical research on Kano's model and customer satisfaction.

    PubMed

    Lin, Feng-Han; Tsai, Sang-Bing; Lee, Yu-Cheng; Hsiao, Cheng-Fu; Zhou, Jie; Wang, Jiangtao; Shang, Zhiwen

    2017-01-01

    Products are now developed based on what customers desire, and thus attractive quality creation has become crucial. In studies on customer satisfaction, methods for analyzing quality attributes and enhancing customer satisfaction have been proposed to facilitate product development. Although substantial studies have performed to assess the impact of the attributes on customer satisfaction, little research has been conducted that quantitatively calculate the odds of customer satisfaction for the Kano classification, fitting a nonlinear relationship between attribute-level performance and customer satisfaction. In the present study, the odds of customer satisfaction were determined to identify the classification of quality attributes, and took customer psychology into account to suggest how decision-makers should prioritize the allocation of resources. A novel method for quantitatively assessing quality attributes was proposed to determine classification criteria and fit the nonlinear relationship between quality attributes and customer satisfaction. Subsequently, a case study was conducted on bicycle user satisfaction to verify the novel method. The concept of customer satisfaction odds was integrated with the value function from prospect theory to understand quality attributes. The results of this study can serve as a reference for product designers to create attractive quality attributes in their products and thus enhance customer satisfaction.

  6. The Introduction of Custom Earplugs Aboard LCS-1

    DTIC Science & Technology

    2016-03-10

    reports on the use of foam and custom HPDs, and provides interim recommendations. Custom-molded HPDs were judged by users to be superior in comfort...and able to be worn for longer periods of time than other devices ( foam ). Based on data from LCS and other related studies, the performance...acceptance, and cost of the custom-molded product are comparable, or better, than foam HPDs. The interim recommendation is to provide multiple types of

  7. Pricing for Higher Education Institutions: A Value-Based Approach

    ERIC Educational Resources Information Center

    Amir, Amizawati Mohd; Auzair, Sofiah Md; Maelah, Ruhanita; Ahmad, Azlina

    2016-01-01

    Purpose: The purpose of this paper is to propose the concept of higher education institutions (HEIs) offering educational services based on value for money. The value is determined based on customers' (i.e. students) expectations of the service and the costs in comparison to the competitors. Understanding the value and creating customer value are…

  8. The airborne mass spectrometer AIMS - Part 2: Measurements of trace gases with stratospheric or tropospheric origin in the UTLS

    NASA Astrophysics Data System (ADS)

    Jurkat, T.; Kaufmann, S.; Voigt, C.; Schäuble, D.; Jeßberger, P.; Ziereis, H.

    2015-12-01

    Understanding the role of climate-sensitive trace gas variabilities in the upper troposphere and lower stratosphere region (UTLS) and their impact on its radiative budget requires accurate measurements. The composition of the UTLS is governed by transport and chemistry of stratospheric and tropospheric constituents, such as chlorine, nitrogen oxide and sulphur components. The Airborne chemical Ionization Mass Spectrometer AIMS has been developed to accurately measure a set of these constituents on aircraft by means of chemical ionization. Here we present a setup using chemical ionization with SF5- reagent ions for the simultaneous measurement of trace gas concentrations in the pptv to ppmv (10-12 to 10-6 mol mol-1) range of HCl, HNO3 and SO2 with in-flight and online calibration called AIMS-TG. Part 1 of this paper (Kaufmann et al., 2015) reports on the UTLS water vapour measurements with the AIMS-H2O configuration. The instrument can be flexibly switched between two configurations depending on the scientific objective of the mission. For AIMS-TG, a custom-made gas discharge ion source has been developed generating a characteristic ionization scheme. HNO3 and HCl are routinely calibrated in-flight using permeation devices, SO2 is permanently calibrated during flight adding an isotopically labelled 34SO2 standard. In addition, we report on trace gas measurements of HONO which is sensitive to the reaction with SF5-. The detection limit for the various trace gases is in the low ten pptv range at a 1 s time resolution with an overall uncertainty of the measurement in the order of 20 %. AIMS has been integrated and successfully operated on the DLR research aircraft Falcon and HALO. Exemplarily, measurements conducted during the TACTS/ESMVal mission with HALO in 2012 are presented, focusing on a classification of tropospheric and stratospheric influences in the UTLS region. Comparison of AIMS measurements with other measurement techniques allow to draw a comprehensive picture of the sulphur, chlorine and reactive nitrogen oxide budget in the UTLS. The combination of the trace gases measured with AIMS exhibit the potential to gain a better understanding of the trace gas origin and variability at and near the tropopause.

  9. Innovative Product Design Based on Comprehensive Customer Requirements of Different Cognitive Levels

    PubMed Central

    Zhao, Wu; Zheng, Yake; Wang, Rui; Wang, Chen

    2014-01-01

    To improve customer satisfaction in innovative product design, a topology structure of customer requirements is established and an innovative product approach is proposed. The topology structure provides designers with reasonable guidance to capture the customer requirements comprehensively. With the aid of analytic hierarchy process (AHP), the importance of the customer requirements is evaluated. Quality function deployment (QFD) is used to translate customer requirements into product and process design demands and pick out the technical requirements which need urgent improvement. In this way, the product is developed in a more targeted way to satisfy the customers. the theory of innovative problems solving (TRIZ) is used to help designers to produce innovative solutions. Finally, a case study of automobile steering system is used to illustrate the application of the proposed approach. PMID:25013862

  10. Innovative product design based on comprehensive customer requirements of different cognitive levels.

    PubMed

    Li, Xiaolong; Zhao, Wu; Zheng, Yake; Wang, Rui; Wang, Chen

    2014-01-01

    To improve customer satisfaction in innovative product design, a topology structure of customer requirements is established and an innovative product approach is proposed. The topology structure provides designers with reasonable guidance to capture the customer requirements comprehensively. With the aid of analytic hierarchy process (AHP), the importance of the customer requirements is evaluated. Quality function deployment (QFD) is used to translate customer requirements into product and process design demands and pick out the technical requirements which need urgent improvement. In this way, the product is developed in a more targeted way to satisfy the customers. the theory of innovative problems solving (TRIZ) is used to help designers to produce innovative solutions. Finally, a case study of automobile steering system is used to illustrate the application of the proposed approach.

  11. Segmentation of Natural Gas Customers in Industrial Sector Using Self-Organizing Map (SOM) Method

    NASA Astrophysics Data System (ADS)

    Masbar Rus, A. M.; Pramudita, R.; Surjandari, I.

    2018-03-01

    The usage of the natural gas which is non-renewable energy, needs to be more efficient. Therefore, customer segmentation becomes necessary to set up a marketing strategy to be right on target or to determine an appropriate fee. This research was conducted at PT PGN using one of data mining method, i.e. Self-Organizing Map (SOM). The clustering process is based on the characteristic of its customers as a reference to create the customer segmentation of natural gas customers. The input variables of this research are variable of area, type of customer, the industrial sector, the average usage, standard deviation of the usage, and the total deviation. As a result, 37 cluster and 9 segment from 838 customer data are formed. These 9 segments then employed to illustrate the general characteristic of the natural gas customer of PT PGN.

  12. Customer and service profitability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballaban, M.; Kelly, K.; Wisniewski, L.

    1996-03-01

    The rapid pace of competitive change in the generation sector has pushed electric utilities to rethink the concept of being obligated to serve all customers and with this change, the notion of measuring customer profitability is also being redefined. Traditionally, uniform services were provided to all customers. Rates were based on each customer classes` contribution to average costs, and consequently return was equally allocated across all customer segments. Profitability was defined strictly on an aggregate basis. The increasing demand for choice by electric customers will require electricity providers to redefine if not who they serve, than certainly how they providemore » differentiated services tailored to specific customer segments. Utilities are beginning to analyze the value, or profitability, of offering these services. Aggregate data no longer provides an accurate assessment of how resources should be allocated most efficiently. As services are unbundled, so too must costs be disaggregated to effectively measure the profitability of various options.« less

  13. Why e-return services fail: a psychological contract violation approach.

    PubMed

    Hsieh, Pei-Ling

    2012-12-01

    This study elucidates why and how e-return services (e-RS) fail, representing a preliminary attempt to explain the critical role of psychological contract violation (PCV) and explore its antecedents and outcomes in e-RS research. Based on marketing, psychology, and information systems-related studies, a theoretical framework is developed to correlate perceived fairness (PF), causal attribution (CA), and magnitude of negative outcome (MNO) with customers' PCV. Additionally, based on trust (TR), exactly how PCV further influences customers' stickiness intention (SI) is examined as well. Analysis results indicate that PF, CA, and MNO influence customers during both the evaluation stage and the customer receipt of e-RS, subsequently deriving PCV. These factors contribute to the subsequent success of e-RS, especially, customers' TR and SI. Furthermore, recommendations are made on how firms should evaluate PCV and its influencing factors to prevent e-RS failure.

  14. Management of Customer Service in Terms of Logistics Information Systems

    NASA Astrophysics Data System (ADS)

    Kampf, Rudolf; Ližbetinová, Lenka; Tišlerová, Kamila

    2017-03-01

    This paper is focused on perceiving the logistic services as the competition advantage in frame of the ecommerce. Customers consider their purchases in its complexity and all the logistic services should be designed to meet with customers' preferences as much as possible. Our aim was to identify and evaluate of customers perceiving in frame of sales proposals offered by e-shops. Collected data of research were processed with the usage of cluster analysis. The aim of this paper is to present the results and conclusions from this research with focus on the elements of logistics services within e-commerce. These outputs can be used for knowledge base of information systems through which enterprises evaluate their decisions and selection of variants. For the enterprise, it is important to appropriate decisions about resource allocation and design of the structure of logistics services were set based on real customer preferences.

  15. New Developments of Broadband Cavity Enhanced Spectroscopic Techniques

    NASA Astrophysics Data System (ADS)

    Walsh, A.; Zhao, D.; Linnartz, H.; Ubachs, W.

    2013-06-01

    In recent years, cavity enhanced spectroscopic techniques, such as cavity ring-down spectroscopy (CRDS), cavity enhanced absorption spectroscopy (CEAS), and broadband cavity enhanced absorption spectroscopy (BBCEAS), have been widely employed as ultra-sensitive methods for the measurement of weak absorptions and in the real-time detection of trace species. In this contribution, we introduce two new cavity enhanced spectroscopic concepts: a) Optomechanical shutter modulated BBCEAS, a variant of BBCEAS capable of measuring optical absorption in pulsed systems with typically low duty cycles. In conventional BBCEAS applications, the latter substantially reduces the signal-to-noise ratio (S/N), consequently also reducing the detection sensitivity. To overcome this, we incorporate a fast optomechanical shutter as a time gate, modulating the detection scheme of BBCEAS and increasing the effective duty cycle reaches a value close to unity. This extends the applications of BBCEAS into pulsed samples and also in time-resolved studies. b) Cavity enhanced self-absorption spectroscopy (CESAS), a new spectroscopic concept capable of studying light emitting matter (plasma, flames, combustion samples) simultaneously in absorption and emission. In CESAS, a sample (plasma, flame or combustion source) is located in an optically stable cavity consisting of two high reflectivity mirrors, and here it acts both as light source and absorbing medium. A high detection sensitivity of weak absorption is reached without the need of an external light source, such as a laser or broadband lamp. The performance is illustrated by the first CESAS result on a supersonically expanding hydrocarbon plasma. We expect CESAS to become a generally applicable analytical tool for real time and in situ diagnostics. A. Walsh, D. Zhao, W. Ubachs, H. Linnartz, J. Phys. Chem. A, {dx.doi.org/10.1021/jp310392n}, in press, 2013. A. Walsh, D. Zhao, H. Linnartz Rev. Sci. Instrum. {84}(2), 021608 2013. A. Walsh, D. Zhao, H. Linnartz Appl. Phys. Lett. {101}(9), 091111 2012.

  16. Technical note: Coupling infrared gas analysis and cavity ring down spectroscopy for autonomous, high-temporal-resolution measurements of DIC and δ13C-DIC

    NASA Astrophysics Data System (ADS)

    Call, Mitchell; Schulz, Kai G.; Carvalho, Matheus C.; Santos, Isaac R.; Maher, Damien T.

    2017-03-01

    A new approach to autonomously determine concentrations of dissolved inorganic carbon (DIC) and its carbon stable isotope ratio (δ13C-DIC) at high temporal resolution is presented. The simple method requires no customised design. Instead it uses two commercially available instruments currently used in aquatic carbon research. An inorganic carbon analyser utilising non-dispersive infrared detection (NDIR) is coupled to a Cavity Ring-down Spectrometer (CRDS) to determine DIC and δ13C-DIC based on the liberated CO2 from acidified aliquots of water. Using a small sample volume of 2 mL, the precision and accuracy of the new method was comparable to standard isotope ratio mass spectrometry (IRMS) methods. The system achieved a sampling resolution of 16 min, with a DIC precision of ±1.5 to 2 µmol kg-1 and δ13C-DIC precision of ±0.14 ‰ for concentrations spanning 1000 to 3600 µmol kg-1. Accuracy of 0.1 ± 0.06 ‰ for δ13C-DIC based on DIC concentrations ranging from 2000 to 2230 µmol kg-1 was achieved during a laboratory-based algal bloom experiment. The high precision data that can be autonomously obtained by the system should enable complex carbonate system questions to be explored in aquatic sciences using high-temporal-resolution observations.

  17. The Influence of Chemical Composition and Relative Humidity on the Optical Properties of Aerosols During the Southern Oxidant and Aerosol Study (SOAS)

    NASA Astrophysics Data System (ADS)

    Attwood, A. R.; Washenfelder, R. A.; Brock, C. A.; Brown, S. S.; Hu, W.; Campuzano Jost, P.; Day, D. A.; Palm, B. B.; Simoes de Sa, S.; Jimenez, J. L.

    2013-12-01

    Atmospheric particles are produced from a wide variety of both anthropogenic and natural sources and play an important role in the Earth's radiative budget by direct scattering and absorption of radiation. To address this impact, in situ measurements of aerosol optical, chemical and hygroscopic properties were performed during the Southern Oxidant and Aerosol Study (SOAS), which took place in the summer of 2013. Ground based measurements of sub-micron aerosol in the southeastern United States were made to investigate the influence of chemical composition and hygroscopicity on aerosol optical properties. We report the wavelength dependence of aerosol extinction cross sections measured with a novel broadband cavity enhanced spectrometer covering a wavelength range of 360-420 nm using two light emitting diodes (LED) and a separate cavity ring down (CRDS) channel. The sensitivity of the relative humidity dependence of extinction based on the type of aerosol present is examined and we show that the optical properties and hygroscopicity of aerosols are greatly influenced by the fraction of sulfate and organics within the particles. Additional data analysis from the SOAS campaign will be presented. The results, thus far, illustrate that the variability in aerosol chemical composition can impact visibility and climate forcing in this region.

  18. Design of compact freeform lens for application specific Light-Emitting Diode packaging.

    PubMed

    Wang, Kai; Chen, Fei; Liu, Zongyuan; Luo, Xiaobing; Liu, Sheng

    2010-01-18

    Application specific LED packaging (ASLP) is an emerging technology for high performance LED lighting. We introduced a practical design method of compact freeform lens for extended sources used in ASLP. A new ASLP for road lighting was successfully obtained by integrating a polycarbonate compact freeform lens of small form factor with traditional LED packaging. Optical performance of the ASLP was investigated by both numerical simulation based on Monte Carlo ray tracing method and experiments. Results demonstrated that, comparing with traditional LED module integrated with secondary optics, the ASLP had advantages of much smaller size in volume (approximately 1/8), higher system lumen efficiency (approximately 8.1%), lower cost and more convenience for customers to design and assembly, enabling possible much wider applications of LED for general road lighting. Tolerance analyses were also conducted. Installation errors of horizontal and vertical deviations had more effects on the shape and uniformity of radiation pattern compared with rotational deviation. The tolerances of horizontal, vertical and rotational deviations of this lens were 0.11 mm, 0.14 mm and 2.4 degrees respectively, which were acceptable in engineering.

  19. Ionizing radiation test results for an automotive microcontroller on board the Schiaparelli Mars lander

    NASA Astrophysics Data System (ADS)

    Tapani Nikkanen, Timo; Hieta, Maria; Schmidt, Walter; Genzer, Maria; Haukka, Harri; Harri, Ari-Matti

    2016-04-01

    The Finnish Meteorological Institute (FMI) has delivered a pressure and a humidity instrument for the ESA ExoMars 2016 Schiaparelli lander mission. Schiaparelli is scheduled to launch towards Mars with the Trace Gas Orbiter on 14th of March 2016. The DREAMS-P (pressure) and DREAMS-H (Humidity) instruments are operated utilizing a novel FMI instrument controller design based on a commercial automotive microcontroller (MCU). A custom qualification program was implemented to qualify the MCU for the relevant launch, cruise and surface operations environment of a Mars lander. Resilience to ionizing radiation is one of the most critical requirements for a digital component operated in space or at planetary bodies. Thus, the expected Total Ionizing Dose accumulated by the MCU was determined and a sample of these components was exposed to a Co-60 gamma radiation source. Part of the samples was powered during the radiation exposure to include the effect of electrical biasing. All of the samples were verified to withstand the expected total ionizing dose with margin. The irradiated test samples were then radiated until failure to determine their ultimate TID.

  20. Ontology for customer centric digital services and analytics

    NASA Astrophysics Data System (ADS)

    Keat, Ng Wai; Shahrir, Mohammad Shazri

    2017-11-01

    In computer science research, ontologies are commonly utilised to create a unified abstract across many rich and different fields. In this paper, we apply the concept to the customer centric domain of digital services analytics and present an analytics solution ontology. The essence is based from traditional Entity Relationship Diagram (ERD), which then was abstracted out to cover wider areas on customer centric digital services. The ontology we developed covers both static aspects (customer identifiers) and dynamic aspects (customer's temporal interactions). The structure of the customer scape is modeled with classes that represent different types of customer touch points, ranging from digital and digital-stamps which represent physical analogies. The dynamic aspects of customer centric digital service are modeled with a set of classes, with the importance is represented in different associations involving establishment and termination of the target interaction. The realized ontology can be used in development of frameworks for customer centric applications, and for specification of common data format used by cooperating digital service applications.

  1. Applying CBR to machine tool product configuration design oriented to customer requirements

    NASA Astrophysics Data System (ADS)

    Wang, Pengjia; Gong, Yadong; Xie, Hualong; Liu, Yongxian; Nee, Andrew Yehching

    2017-01-01

    Product customization is a trend in the current market-oriented manufacturing environment. However, deduction from customer requirements to design results and evaluation of design alternatives are still heavily reliant on the designer's experience and knowledge. To solve the problem of fuzziness and uncertainty of customer requirements in product configuration, an analysis method based on the grey rough model is presented. The customer requirements can be converted into technical characteristics effectively. In addition, an optimization decision model for product planning is established to help the enterprises select the key technical characteristics under the constraints of cost and time to serve the customer to maximal satisfaction. A new case retrieval approach that combines the self-organizing map and fuzzy similarity priority ratio method is proposed in case-based design. The self-organizing map can reduce the retrieval range and increase the retrieval efficiency, and the fuzzy similarity priority ratio method can evaluate the similarity of cases comprehensively. To ensure that the final case has the best overall performance, an evaluation method of similar cases based on grey correlation analysis is proposed to evaluate similar cases to select the most suitable case. Furthermore, a computer-aided system is developed using MATLAB GUI to assist the product configuration design. The actual example and result on an ETC series machine tool product show that the proposed method is effective, rapid and accurate in the process of product configuration. The proposed methodology provides a detailed instruction for the product configuration design oriented to customer requirements.

  2. A systematic study of posterior cervical lymph node irradiation with electrons: Conventional versus customized planning.

    PubMed

    Jankowska, Petra J; Kong, Christine; Burke, Kevin; Harrington, Kevin J; Nutting, Christopher

    2007-10-01

    High dose irradiation of the posterior cervical lymph nodes usually employs applied electron fields to treat the target volume and maintain the spinal cord dose within tolerance. In the light of recent advances in elective lymph node localisation we investigated optimization of field shape and electron energy to treat this target volume. In this study, three sequential hypotheses were tested. Firstly, that customization of the electron fields based on the nodal PTV outlined gives better PTV coverage than conventional field delineation. Using the consensus guidelines, customization of the electron field shape was compared to conventional fields based on bony landmarks. Secondly, that selection of electron energy using DVHs for spinal cord and PTV improves the minimum dose to PTV. Electron dose-volume histograms (DVHs) for the PTV, spinal cord and para-vertebral muscles, were generated using the Monte Carlo electron algorithm. These DVHs were used to compare standard vs optimized electron energy calculations. Finally, that combination of field customization and electron energy optimization improves both the minimum and mean doses to PTV compared with current standard practice. Customized electron beam shaping based on the consensus guidelines led to fewer geographical misses than standard field shaping. Customized electron energy calculation led to higher minimum doses to the PTV. Overall, the customization of field shape and energy resulted in an improved mean dose to the PTV (92% vs 83% p=0.02) and a 27% improvement in the minimum dose delivered to the PTV (45% vs 18% p=0.0009). Optimization of electron field shape and beam energy based on current consensus guidelines led to significant improvement in PTV coverage and may reduce recurrence rates.

  3. The use of ion mobility spectrometry and gas chromatography/mass spectrometry for the detection of illicit drugs on clandestine records

    NASA Technical Reports Server (NTRS)

    Donnelly, Brian; Jourdan, Thomas; Fetterolf, Dean D.; Beasley, James O., II

    1995-01-01

    Illicit drug distribution has over the past decade grown tremendously from simple 'drug pushing' where drugs were distributed from poorly organized individuals to today's well organized and well financed drug cartels. This change to a more 'corporate-like' atmosphere has resulted in a greater use of record keeping to monitor the profits generated. The use of record keeping by drug distributors is not restricted to high level drug smugglers but is used at all levels within the distribution network. Dealers at all levels including street dealers are generally 'fronted', given on consignment quantities of drugs that they in turn sell to customers, thereby requiring the need for records to keep track of drug sales versus liabilities. These records because of their illicit nature are often encrypted to hide the fact that they are indeed records of drug transactions. The creation of a handwritten notation concerning a drug transaction is normally brought on because of a purchase or sale. In a sale, this is commonly accomplished through a consignment, or the designation of a quantity to a customer to whom that amount has been 'fronted'. Because this activity generates a debt, it follows that an accounting for payments made, as well as new transactions completed, is only logical. One of the most common means of representing these is through an 'accounting flow', in which payments are subtracted from a running balance while new sales are added to it. The examination of illicit drug records has been the key to the prosecution of numerous federal, state, and local drug cases for a number of years. The Document Section of the FBI Laboratory, through its Racketeering Records Analysis Unit (RRAU), has been involved in such analytical efforts since 1983. Detailed analytical research brought about an evolution in the systematic approach utilized in the RRAU since that time. The close proximity of the drugs to the records often results in trace drug evidence being transferred to the records. The detection of trace drug residue on surfaces by ion mobility spectrometry (IMS) is well documented in literature. The following procedure will deal primarily with the newer techniques of trace drug analysis and drug record analysis developed by the Chemistry/Toxicology Unit of the FBI Laboratory since the more traditional techniques of latent finger print analysis and document analysis are well known.

  4. The airborne mass spectrometer AIMS - Part 2: Measurements of trace gases with stratospheric or tropospheric origin in the UTLS

    NASA Astrophysics Data System (ADS)

    Jurkat, Tina; Kaufmann, Stefan; Voigt, Christiane; Schäuble, Dominik; Jeßberger, Philipp; Ziereis, Helmut

    2016-04-01

    Understanding the role of climate-sensitive trace gas variabilities in the upper troposphere and lower stratosphere region (UTLS) and their impact on its radiative budget requires accurate measurements. The composition of the UTLS is governed by transport and chemistry of stratospheric and tropospheric constituents, such as chlorine, nitrogen oxide and sulfur compounds. The Atmospheric chemical Ionization Mass Spectrometer AIMS has been developed to accurately measure a set of these constituents on aircraft by means of chemical ionization. Here we present a setup using SF5- reagent ions for the simultaneous measurement of trace gas concentrations of HCl, HNO3 and SO2 in the pptv to ppmv (10-12 to 10-6 mol mol-1) range with in-flight and online calibration called AIMS-TG (Atmospheric chemical Ionization Mass Spectrometer for measurements of trace gases). Part 1 of this paper (Kaufmann et al., 2016) reports on the UTLS water vapor measurements with the AIMS-H2O configuration. The instrument can be flexibly switched between two configurations depending on the scientific objective of the mission. For AIMS-TG, a custom-made gas discharge ion source has been developed for generation of reagent ions that selectively react with HCl, HNO3, SO2 and HONO. HNO3 and HCl are routinely calibrated in-flight using permeation devices; SO2 is continuously calibrated during flight adding an isotopically labeled 34SO2 standard. In addition, we report on trace gas measurements of HONO, which is sensitive to the reaction with SF5-. The detection limit for the various trace gases is in the low 10 pptv range at a 1 s time resolution with an overall uncertainty of the measurement of the order of 20 %. AIMS has been integrated and successfully operated on the DLR research aircraft Falcon and HALO (High Altitude LOng range research aircraft). As an example, measurements conducted during the TACTS/ESMVal (Transport and Composition of the LMS/UT and Earth System Model Validation) mission with HALO in 2012 are presented, focusing on a classification of tropospheric and stratospheric influences in the UTLS region. The combination of AIMS measurements with other measurement techniques yields a comprehensive picture of the sulfur, chlorine and reactive nitrogen oxide budget in the UTLS. The different trace gases measured with AIMS exhibit the potential to gain a better understanding of the trace gas origin and variability at and near the tropopause.

  5. Community pharmacy customer segmentation based on factors influencing their selection of pharmacy and over-the-counter medicines.

    PubMed

    Kevrekidis, Dimitrios Phaedon; Minarikova, Daniela; Markos, Angelos; Malovecka, Ivona; Minarik, Peter

    2018-01-01

    Within the competitive pharmacy market environment, community pharmacies are required to develop efficient marketing strategies based on contemporary information about consumer behavior in order to attract clients and develop customer loyalty. This study aimed to investigate the consumers' preferences concerning the selection of pharmacy and over-the-counter (OTC) medicines, and to identify customer segments in relation to these preferences. A cross-sectional study was conducted between February and March 2016 on a convenient quota sample of 300 participants recruited in the metropolitan area of Thessaloniki, Greece. The main instrument used for data collection was a structured questionnaire with close-ended, multiple choice questions. To identify customer segments, Two-Step cluster analysis was conducted. Three distinct pharmacy customer clusters emerged. Customers of the largest cluster (49%; 'convenience customers') were mostly younger consumers. They gave moderate to positive ratings to factors affecting the selection of pharmacy and OTCs; convenience, and previous experience and the pharmacist's opinion, received the highest ratings. Customers of the second cluster (35%; 'loyal customers') were mainly retired; most of them reported visiting a single pharmacy. They gave high ratings to all factors that influence pharmacy selection, especially the pharmacy's staff, and factors influencing the purchase of OTCs, particularly previous experience and the pharmacist's opinion. Customers of the smallest cluster (16%; 'convenience and price-sensitive customers') were mainly retired or unemployed with low to moderate education, and low personal income. They gave the lowest ratings to most of the examined factors; convenience among factors influencing pharmacy selection, whereas previous experience, the pharmacist's opinion and product price among those affecting the purchase of OTCs, received the highest ratings. The community pharmacy market comprised of distinct customer segments that varied in the consumer preferences concerning the selection of pharmacy and OTCs, the evaluation of pharmaceutical services and products, and demographic characteristics.

  6. E-Commerce and Privacy: Conflict and Opportunity.

    ERIC Educational Resources Information Center

    Farah, Badie N.; Higby, Mary A.

    2001-01-01

    Electronic commerce has intensified conflict between businesses' need to collect data and customers' desire to protect privacy. Web-based privacy tools and legislation could add to the costs of e-commerce and reduce profitability. Business models not based on profiling customers may be needed. (SK)

  7. 78 FR 3934 - Self-Regulatory Organizations; International Securities Exchange, LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ... Symbols, 2) increase the maker fee for complex orders that trade against Priority Customer complex orders... provides volume-based tiered rebates for Priority Customer complex orders in the Select Symbols (excluding... orders trade with non-Priority Customer orders in the complex order book. In the Select Symbols, the...

  8. 12 CFR 567.6 - Risk-based capital credit risk-weight categories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., but only if the originating bank remains liable to the customer or beneficiary for the full amount of... considered timely if they are not 30 days past due; (D) Qualifying residential construction loans as defined...) Indemnification of customers whose securities the savings association has lent as agent. If the customer is not...

  9. 76 FR 77034 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Notice of Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-09

    ... Accelerated Approval of Proposed Rule Change To Amend FINRA Rule 4512 (Customer Account Information) December... the Proposed Rule Change FINRA proposes to amend FINRA Rule 4512 (Customer Account Information) to... requires firms to maintain certain information relating to customer accounts, and it is based on existing...

  10. 75 FR 8772 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Order Approving...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ... broker-customer relationship; or (5) the lending arrangement is based on a business relationship outside of the broker-customer relationship. In addition, with the exception of lending arrangements between... for a loan that is not the product of the broker- customer relationship would not vitiate the idea...

  11. The Role of Interactivity in Internet Business on Customer Experiential Values and Behavioral Intentions

    ERIC Educational Resources Information Center

    Park, So Ra

    2012-01-01

    Customers' experiential value is based on holistic experience customers would have when they interact with a product/service. Experiential value is defined as "relativistic preference characterizing a subject's experience with some object" (Holbrook, 1994). Internet is characterized for interactivity and it should have a role in…

  12. B2C Mass Customization in the Classroom

    ERIC Educational Resources Information Center

    Visich, John K.; Gu, Qiannong; Khumawala, Basheer M.

    2012-01-01

    The purpose of this article is to describe an internet-based mass customization assignment in Operations Management/Supply Chain Management classes where students utilize the Web site of a company that offers a customized product. Students evaluate the user interface, judge the value proposition of the product they demonstrate, and discuss issues…

  13. 78 FR 60966 - Self-Regulatory Organizations: Miami International Securities Exchange LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-02

    .... As such, marketing fee programs,\\7\\ and customer posting incentive programs,\\8\\ are based on... its current Priority Customer Rebate Program (the ``Program'') until October 31, 2013.\\3\\ The Program... Priority Customer \\6\\ order transmitted by that Member which is executed on the Exchange in all multiply...

  14. 78 FR 66094 - Self-Regulatory Organizations: Miami International Securities Exchange LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... Priority Customer Rebate Program (the ``Program'') until November 30, 2013.\\3\\ The Program currently... Customer \\6\\ order transmitted by that Member which is executed on the Exchange in all multiply-listed... thresholds are calculated based on the customer average daily volume over the course of the month. Volume...

  15. Sales Communications in a Mobile World: Using the Latest Technology and Retaining the Personal Touch

    ERIC Educational Resources Information Center

    Norris, Daniel T.

    2007-01-01

    Salespeople increasingly have the opportunity to use technology to more quickly communicate with a larger number of clients and customers. Mobile technology, in particular, gives salespeople many advantages in rapidly reaching a large customer base. Furthermore, customers are increasingly employing mobile technology, making them increasingly…

  16. 78 FR 36744 - Diamond Sawblades and Parts Thereof From the People's Republic of China: Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-19

    ... management, production facilities, supplier relationships, and customer base.\\5\\ While no single factor or... significant changes to management, production facilities, supplier relationships, and customers. As a result..., production facilities, and customer/ supplier relationships have not changed as a result of the name change...

  17. 75 FR 1672 - Self-Regulatory Organizations; Financial Industry Regulatory Authority, Inc.; Notice of Filing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-12

    ... personal relationship outside of the broker-customer relationship; or (5) the lending arrangement is based on a business relationship outside of the broker-customer relationship. In addition, with the... better rate or terms for a loan that is not the product of the broker- customer relationship would not...

  18. The interplay between customer participation and difficulty of design examples in the online designing process and its effect on customer satisfaction: mediational analyses.

    PubMed

    Chang, Chia-Chi; Chen, Hui-Yun; Huang, I-Chiang

    2009-04-01

    In the current consumer-centric economy, consumers increasingly desire the opportunity to design their own products in order to express more effectively their self-image. Mass customization, based on efficient and flexible modulization designs, has provided individualized products to satisfy this desire. This work presents an experiment employed to demonstrate that customer participation leads to higher satisfaction. Specifically, the increment in customer satisfaction due to participation is greater when an easy example is provided than when either no example or a difficult one is provided. Additionally, self-congruity plays a mediating role on the customer participation-satisfaction relationship, and this mediating effect varies across different levels of the design example provided in the design process. When an easy design example is present, customer participation has a direct effect on satisfaction, in addition to the indirect effect of self-congruity. When a difficult example is provided, customer participation does not have incremental effects on either self-congruity or customer satisfaction. Finally, when no design example is shown to customers, contrary to our expectation, participation still enhances customer satisfaction due to an increased sense of self-congruity.

  19. Variables contributing to an excellent customer service management profile within the regulated electric utility industry: A comparison of self-concept with customer satisfaction for customer service management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, L.E.

    1991-01-01

    This research sought to address the relationship between self-concept and customer satisfaction: can customer satisfaction with a major electric utility be explained in terms of the self-reported, self-concept of the utility's managers The population to which the results of this study were generalized consisted of customer service managers in public electric utilities across the United States. In order to represent this population, a sample was selected consisting of customer service managers at a midwestern electric utility based in a large metropolitan area. Participants in this study were managers of four direct customer contact service organizations within six geographic division organizations.more » The methodology included comparisons of these four customer contact service organizations on twelve independent, self-concept variables and six customer satisfaction dependent variables using Analysis of Variance (ANOVA), Scheffe' tests, Chi-Square, and Stepwise multiple regression. The groups were found not to be significantly different and knowledge of the self-concept scores for managers will not increase the ability to predict customer satisfaction over no knowledge of self-concept scores.« less

  20. Acceleration of block-matching algorithms using a custom instruction-based paradigm on a Nios II microprocessor

    NASA Astrophysics Data System (ADS)

    González, Diego; Botella, Guillermo; García, Carlos; Prieto, Manuel; Tirado, Francisco

    2013-12-01

    This contribution focuses on the optimization of matching-based motion estimation algorithms widely used for video coding standards using an Altera custom instruction-based paradigm and a combination of synchronous dynamic random access memory (SDRAM) with on-chip memory in Nios II processors. A complete profile of the algorithms is achieved before the optimization, which locates code leaks, and afterward, creates a custom instruction set, which is then added to the specific design, enhancing the original system. As well, every possible memory combination between on-chip memory and SDRAM has been tested to achieve the best performance. The final throughput of the complete designs are shown. This manuscript outlines a low-cost system, mapped using very large scale integration technology, which accelerates software algorithms by converting them into custom hardware logic blocks and showing the best combination between on-chip memory and SDRAM for the Nios II processor.

  1. Study and Development of Mobile Tracingterminal Based on Gprs for Agriculturalproducts Quality Tracking

    NASA Astrophysics Data System (ADS)

    Liu, Shihong; Meng, Hong; Zheng, Huoguo; Wu, Jiangshou

    Traceability system has become an important means for food safety management. Global food industry and many countries have paid increasing attention to the construction of food traceability system, but rarely referred to tracing terminal. According to the technical requirements of cereal and oil products quality safety tracing process, we design and develop a mobile tracing terminal based on GPRS for agricultural products quality tracking to facilitate quality supervisors and consumers to track and trace the quality of related agricultural products anytime ,anywhere.

  2. Development of a composite large-size SiPM (assembled matrix) based modular detector cluster for MAGIC

    NASA Astrophysics Data System (ADS)

    Hahn, A.; Mazin, D.; Bangale, P.; Dettlaff, A.; Fink, D.; Grundner, F.; Haberer, W.; Maier, R.; Mirzoyan, R.; Podkladkin, S.; Teshima, M.; Wetteskind, H.

    2017-02-01

    The MAGIC collaboration operates two 17 m diameter Imaging Atmospheric Cherenkov Telescopes (IACTs) on the Canary Island of La Palma. Each of the two telescopes is currently equipped with a photomultiplier tube (PMT) based imaging camera. Due to the advances in the development of Silicon Photomultipliers (SiPMs), they are becoming a widely used alternative to PMTs in many research fields including gamma-ray astronomy. Within the Otto-Hahn group at the Max Planck Institute for Physics, Munich, we are developing a SiPM based detector module for a possible upgrade of the MAGIC cameras and also for future experiments as, e.g., the Large Size Telescopes (LST) of the Cherenkov Telescope Array (CTA). Because of the small size of individual SiPM sensors (6 mm×6 mm) with respect to the 1-inch diameter PMTs currently used in MAGIC, we use a custom-made matrix of SiPMs to cover the same detection area. We developed an electronic circuit to actively sum up and amplify the SiPM signals. Existing non-imaging hexagonal light concentrators (Winston cones) used in MAGIC have been modified for the angular acceptance of the SiPMs by using C++ based ray tracing simulations. The first prototype based detector module includes seven channels and was installed into the MAGIC camera in May 2015. We present the results of the first prototype and its performance as well as the status of the project and discuss its challenges.

  3. Incentive-Based Voltage Regulation in Distribution Networks: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Xinyang; Chen, Lijun; Dall'Anese, Emiliano

    This paper considers distribution networks fea- turing distributed energy resources, and designs incentive-based mechanisms that allow the network operator and end-customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Two different network-customer coordination mechanisms that require different amounts of information shared between the network operator and end-customers are developed to identify a solution of a well-defined social-welfare maximization prob- lem. Notably, the signals broadcast by the network operator assume the connotation of prices/incentives that induce the end- customers to adjust the generated/consumed powers in order to avoid the violation of the voltagemore » constraints. Stability of the proposed schemes is analytically established and numerically corroborated.« less

  4. Incentive-Based Voltage Regulation in Distribution Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dall-Anese, Emiliano; Baker, Kyri A; Zhou, Xinyang

    This paper considers distribution networks fea- turing distributed energy resources, and designs incentive-based mechanisms that allow the network operator and end-customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Two different network-customer coordination mechanisms that require different amounts of information shared between the network operator and end-customers are developed to identify a solution of a well-defined social-welfare maximization prob- lem. Notably, the signals broadcast by the network operator assume the connotation of prices/incentives that induce the end- customers to adjust the generated/consumed powers in order to avoid the violation of the voltagemore » constraints. Stability of the proposed schemes is analytically established and numerically corroborated.« less

  5. Customers' expectations of complaint handling by airline service: privilege status and reasonability of demands from a social learning perspective.

    PubMed

    Chiou, Wen-Bin; Chang, Ming-Hsu; Yang, Chao-Chin

    2009-04-01

    In the airline industry, membership and cabin class are noticeable servicescape features of customers' privilege status. Customers may learn that higher privilege customers are more desired and endured by the airline. From the customers' point of view, those with higher privilege may expect their demands to be complied with when they complain. The present study employed hypothetical scenarios to investigate how the privilege status of passengers and reasonability of their demands influenced their expectations toward the compliance of airline personnel. Analysis showed that higher privilege customers were more likely to expect airline personnel to comply with their demands. Moreover, participants with medium or high levels of privilege status had greater expectations of compliance even when demands were unreasonable. In sum, customer expectations toward complaint handling reflected predictions based on social learning.

  6. Sticks and stones can break my bones but words can also hurt me: The relationship between customer verbal aggression and employee incivility.

    PubMed

    Walker, David D; van Jaarsveld, Danielle D; Skarlicki, Daniel P

    2017-02-01

    Customer service employees tend to react negatively to customer incivility by demonstrating incivility in return, thereby likely reducing customer service quality. Research, however, has yet to uncover precisely what customers do that results in employee incivility. Through transcript and computerized text analysis in a multilevel, multisource, mixed-method field study of customer service events (N = 434 events), we found that employee incivility can occur as a function of customer (a) aggressive words, (b) second-person pronoun use (e.g., you, your), (c) interruptions, and (d) positive emotion words. First, the positive association between customer aggressive words and employee incivility was more pronounced when the verbal aggression included second-person pronouns, which we label targeted aggression. Second, we observed a 2-way interaction between targeted aggression and customer interruptions such that employees demonstrated more incivility when targeted customer verbal aggression was accompanied by more (vs. fewer) interruptions. Third, this 2-way interaction predicting employee incivility was attenuated when customers used positive emotion words. Our results support a resource-based explanation, suggesting that customer verbal aggression consumes employee resources potentially leading to self-regulation failure, whereas positive emotion words from customers can help replenish employee resources that support self-regulation. The present study highlights the advantages of examining what occurs within customer-employee interactions to gain insight into employee reactions to customer incivility. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Building brand equity and customer loyalty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokorny, G.

    Customer satisfaction and customer loyalty are two different concepts, not merely two different phrases measuring a single consumer attitude. Utilities having identical customer satisfaction ratings based on performance in areas like power reliability, pricing, and quality of service differ dramatically in their levels of customer loyalty. As competitive markets establish themselves, discrepancies in customer loyalty will have profound impacts on each utility`s prospects for market retention, profitability, and ultimately, shareholder value. Meeting pre-existing consumer needs, wants and preferences is the foundation of any utility strategy for building customer loyalty and market retention. Utilities meet their underlying customer expectations by performingmore » well in three discrete areas: product, customer service programs, and customer service transactions. Brand equity is an intervening variable standing between performance and the loyalty a utility desires. It is the totality of customer perceptions about the unique extra value the utility provides above and beyond its basic product, customer service programs and customer service transactions; it is the tangible, palpable reality of a branded utility that exists in the minds of consumers. By learning to manage their brand equity as well as they manage their brand performance, utilities gain control over all the major elements in the value-creation process that creates customer loyalty. By integrating brand performance and brand equity, electric utility companies can truly become in their customers` eyes a brand - a unique, very special, value-added energy services provider that can ask for and deserve a premium price in the marketplace.« less

  8. A Methodology and Software Environment for Testing Process Model’s Sequential Predictions with Protocols

    DTIC Science & Technology

    1992-12-21

    in preparation). Foundations of artificial intelligence. Cambridge, MA: MIT Press. O’Reilly, R. C. (1991). X3DNet: An X- Based Neural Network ...2.2.3 Trace based protocol analysis 19 2.2A Summary of important data features 21 2.3 Tools related to process model testing 23 2.3.1 Tools for building...algorithm 57 3. Requirements for testing process models using trace based protocol 59 analysis 3.1 Definition of trace based protocol analysis (TBPA) 59

  9. Development of a novel imaging informatics-based system with an intelligent workflow engine (IWEIS) to support imaging-based clinical trials

    PubMed Central

    Wang, Ximing; Liu, Brent J; Martinez, Clarisa; Zhang, Xuejun; Winstein, Carolee J

    2015-01-01

    Imaging based clinical trials can benefit from a solution to efficiently collect, analyze, and distribute multimedia data at various stages within the workflow. Currently, the data management needs of these trials are typically addressed with custom-built systems. However, software development of the custom- built systems for versatile workflows can be resource-consuming. To address these challenges, we present a system with a workflow engine for imaging based clinical trials. The system enables a project coordinator to build a data collection and management system specifically related to study protocol workflow without programming. Web Access to DICOM Objects (WADO) module with novel features is integrated to further facilitate imaging related study. The system was initially evaluated by an imaging based rehabilitation clinical trial. The evaluation shows that the cost of the development of system can be much reduced compared to the custom-built system. By providing a solution to customize a system and automate the workflow, the system will save on development time and reduce errors especially for imaging clinical trials. PMID:25870169

  10. Building customer capital through knowledge management processes in the health care context.

    PubMed

    Liu, Sandra S; Lin, Carol Yuh-Yun

    2007-01-01

    Customer capital is a value generated and an asset developed from customer relationships. Successfully managing these relationships is enhanced by knowledge management (KM) infrastructure that captures and transfers customer-related knowledge. The execution of such a system relies on the vision and determination of the top management team (TMT). The health care industry in today's knowledge economy encounters similar challenges of consumerism as its business sector. Developing customer capital is critical for hospitals to remain competitive in the market. This study aims to provide taxonomy for cultivating market-based organizational learning that leads to building of customer capital and attaining desirable financial performance in health care. With the advancement of technology, the KM system plays an important moderating role in the entire process. The customer capital issue has not been fully explored either in the business or the health care industry. The exploratory nature of such a pursuit calls for a qualitative approach. This study examines the proposed taxonomy with the case hospital. The lessons learned also are reflected with three US-based health networks. The TMT incorporated the knowledge process of conceptualization and transformation in their organizational mission. The market-oriented learning approach promoted by TMT helps with the accumulation and sharing of knowledge that prepares the hospital for the dynamics in the marketplace. Their key knowledge advancement relies on both the professional arena and the feedback of customers. The institutionalization of the KM system and organizational culture expands the hospital's customer capital. The implication is twofold: (1) the TMT is imperative for the success of building customer capital through KM process; and (2) the team effort should be enhanced with a learning culture and sharing spirit, in particular, active nurse participation in decision making and frontline staff's role in providing a delightfully surprising patient experience.

  11. The CO2 absorption continuum by high pressure CRDS in the 1.74 μm window

    NASA Astrophysics Data System (ADS)

    Mondelain, D.; Campargue, A.; Čermák, P.; Gamache, R. R.; Kassi, S.; Tashkun, S. A.; Tran, H.

    2017-12-01

    The very weak absorption continuum of CO2 is studied by Cavity Ring Down Spectroscopy in three 20 cm-1 wide spectral intervals near the centre of the 1.74 μm window (5693-5795 cm-1). For each spectral interval, a set of room temperature spectra is recorded at pressures between 0 and 10 bar thanks to a high pressure CRDS spectrometer. The absorption continuum is retrieved after subtraction of the contributions due to Rayleigh scattering and to local lines of CO2 and water (present as an impurity in the sample) from the measured extinction. Due to some deficiencies of the CO2 HITRAN2012 line list, a composite line list had to be built on the basis of the Ames calculated line list with line positions adjusted according to the Carbon Dioxide Spectroscopic Databank and self-broadening and pressure shift coefficients calculated with the Complex Robert Bonamy method. The local line contribution of the CO2 monomer is calculated using this list and a Voigt profile truncated at ±25 cm-1 from the line centre. Line mixing effects were taken into account through the use of the impact and Energy Corrected Sudden approximations. The density dependence of the retrieved continuum absorption was found to be purely quadratic in the low frequency interval below 5710 cm-1 but a small significant linear contribution was required to reproduce the observations above this value. This linear increase is tentatively attributed to the foreign-continuum of water vapor present in CO2 sample with a relative concentration of some tens ppm. The retrieved binary coefficient is observed to vary smoothly with the wavenumber with a minimum value of 6×10-10 cm-1 amagat-2. By gathering the present data with the results reported in Kassi et al. J Quant Spectrosc Radiat Transf 2015;167:97, a recommended set of binary coefficients is provided for the 5700-5950 cm-1 region.

  12. Experimental and Modeling Investigation of the Low-Temperature Oxidation of Dimethyl Ether.

    PubMed

    Rodriguez, Anne; Frottier, Ophélie; Herbinet, Olivier; Fournet, René; Bounaceur, Roda; Fittschen, Christa; Battin-Leclerc, Frédérique

    2015-07-16

    The oxidation of dimethyl ether (DME) was studied using a jet-stirred reactor over a wide range of conditions: temperatures from 500 to 1100 K; equivalence ratios of 0.25, 1, and 2; residence time of 2 s; pressure of 106.7 kPa (close to the atmospheric pressure); and an inlet fuel mole fraction of 0.02 (with high dilution in helium). Reaction products were quantified using two analysis methods: gas chromatography and continuous wave cavity ring-down spectroscopy (cw-CRDS). cw-CRDS enabled the quantification of formaldehyde, which is one of the major products from DME oxidation, as well as that of hydrogen peroxide, which is an important branching agent in low-temperature oxidation chemistry. Experimental data were compared with data computed using models from the literature with important deviations being observed for the reactivity at low-temperature. A new detailed kinetic model for the oxidation of DME was developed in this study. Kinetic parameters used in this model were taken from literature or calculated in the present work using quantum calculations. This new model enables a better prediction of the reactivity in the low-temperature region. Under the present JSR conditions, error bars on predictions were given. Simulations were also successfully compared with experimental flow reactor, jet-stirred reactor, shock tube, rapid compression machine, and flame data from literature. The kinetic analysis of the model enabled the highlighting of some specificities of the oxidation chemistry of DME: (1) the early reactivity which is observed at very low-temperature (e.g., compared to propane) is explained by the absence of inhibiting reaction of the radical directly obtained from the fuel (by H atom abstraction) with oxygen yielding an olefin + HO2·; (2) the low-temperature reactivity is driven by the relative importance of the second addition to O2 (promoting the reactivity through branching chain) and the competitive decomposition reactions with an inhibiting effect.

  13. Physiotherapy and cardiac rhythm devices: a review of the current scope of practice.

    PubMed

    Digby, Geneviève C; Daubney, Marguerite E; Baggs, Jim; Campbell, Debra; Simpson, Christopher S; Redfearn, Damian P; Brennan, F James; Abdollah, Hoshiar; Baranchuk, Adrian

    2009-07-01

    Several case reports have demonstrated negative interactions between various physiotherapy modalities and cardiac rhythm devices (CRD). Fear of these potential interactions may lead to suboptimal utilization of physiotherapy treatments in CRD patients. No prior review of available guidelines, or management strategies, on the interaction between physiotherapy modalities and CRD patients has been reported. To review existing guidelines regarding the use of physiotherapy modalities in patients with pacemakers and/or implantable cardioverter-defibrillators (ICDs). To retrospectively analyse CRD patient encounters at a local physiotherapy facility during a period of 2 years. A review of the literature regarding the potential interactions between physiotherapy modalities and CRDs was performed. Next, a 2 year retrospective analysis of patient encounters at a physiotherapy facility was conducted. In addition, seven international physiotherapy societies and four CRD manufacturers were surveyed with respect to recommendations regarding physiotherapy treatments in device patients. The local physiotherapy facility treated 25 patients with CRD (22 pacemaker and 3 ICD patients) for a total of 230 visits (9.2 visits/patient). Five patients received transcutaneous electrical nerve stimulation (TENS) and all 25 were administered additional treatment in the form of ultrasound (15), acupuncture (19), Laser (7), traction/manual therapy (12), exercise (8), education (18), taping (5), and/or moist heat (5). No complications occurred. Meanwhile, international societies and device manufacturers offered few specific or consistent recommendations. There are no specific international policies regarding the administration of physiotherapy modalities in CRD patients and, thus, there are no specific guidelines to be implemented at the local level. Review of the literature and of recommendations from CRD manufacturers suggests that TENS, Diathermy, and Interferential Electrical Current Therapy are best avoided in patients with CRDs. However, there is no consensus and it may be possible to safely deliver these modalities in a proper setting with device and patient monitoring. Although further research is required in this regard, active collaboration between physiotherapists and CRD clinic physicians should allow for the safe application of most physiotherapy modalities.

  14. Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).

    PubMed

    West, A G; Goldsmith, G R; Matimati, I; Dawson, T E

    2011-08-30

    Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Cavity enhanced spectroscopy for measurement of nitrogen oxides in the Anthropocene: results from the Seoul tower during MAPS 2015.

    PubMed

    Brown, Steven S; An, Hyunjin; Lee, Meehye; Park, Jeong-Hoo; Lee, Sang-Deok; Fibiger, Dorothy L; McDuffie, Erin E; Dubé, William P; Wagner, Nicholas L; Min, Kyung-Eun

    2017-08-24

    Cavity enhanced spectroscopy, CES, is a high sensitivity direct absorption method that has seen increasing utility in the last decade, a period also marked by increasing requirements for understanding human impacts on atmospheric composition. This paper describes the current NOAA six channel cavity ring-down spectrometer (CRDS, the most common form of CES) for measurement of nitrogen oxides and O 3 . It further describes the results from measurements from a tower 300 m above the urban area of Seoul in late spring of 2015. The campaign demonstrates the performance of the CRDS instrument and provides new data on both photochemistry and nighttime chemistry in a major Asian megacity. The instrument provided accurate, high time resolution data for N 2 O 5 , NO, NO 2 , NO y and O 3 , but suffered from large wall loss in the sampling of NO 3 , illustrating the requirement for calibration of the NO 3 inlet transmission. Both the photochemistry and nighttime chemistry of nitrogen oxides and O 3 were rapid in this megacity. Sustained average rates of O 3 buildup of 10 ppbv h -1 during recurring morning and early afternoon sea breezes led to a 50 ppbv average daily O 3 rise. Nitrate radical production rates, P(NO 3 ), averaged 3-4 ppbv h -1 in late afternoon and early evening, much greater than contemporary data from Los Angeles, a comparable U. S. megacity. These P(NO 3 ) were much smaller than historical data from Los Angeles, however. Nighttime data at 300 m above ground showed considerable variability in high time resolution nitrogen oxide and O 3 , likely resulting from sampling within gradients in the nighttime boundary layer structure. Apparent nighttime biogenic VOC oxidation rates of several ppbv h -1 were also likely influenced by vertical gradients. Finally, daytime N 2 O 5 mixing ratios of 3-35 pptv were associated with rapid daytime P(NO 3 ) and agreed well with a photochemical steady state calculation.

  16. Negative correlation learning for customer churn prediction: a comparison study.

    PubMed

    Rodan, Ali; Fayyoumi, Ayham; Faris, Hossam; Alsakran, Jamal; Al-Kadi, Omar

    2015-01-01

    Recently, telecommunication companies have been paying more attention toward the problem of identification of customer churn behavior. In business, it is well known for service providers that attracting new customers is much more expensive than retaining existing ones. Therefore, adopting accurate models that are able to predict customer churn can effectively help in customer retention campaigns and maximizing the profit. In this paper we will utilize an ensemble of Multilayer perceptrons (MLP) whose training is obtained using negative correlation learning (NCL) for predicting customer churn in a telecommunication company. Experiments results confirm that NCL based MLP ensemble can achieve better generalization performance (high churn rate) compared with ensemble of MLP without NCL (flat ensemble) and other common data mining techniques used for churn analysis.

  17. Skeleton-based tracing of curved fibers from 3D X-ray microtomographic imaging

    NASA Astrophysics Data System (ADS)

    Huang, Xiang; Wen, Donghui; Zhao, Yanwei; Wang, Qinghui; Zhou, Wei; Deng, Daxiang

    A skeleton-based fiber tracing algorithm is described and applied on a specific fibrous material, porous metal fiber sintered sheet (PMFSS), featuring high porosity and curved fibers. The skeleton segments are firstly categorized according to the connectivity of the skeleton paths. Spurious segments like fiber bonds are detected making extensive use of the distance transform (DT) values. Single fibers are then traced and reconstructed by consecutively choosing the connecting skeleton segment pairs that show the most similar orientations and radius. Moreover, to reduce the misconnection due to the tracing orders, a multilevel tracing strategy is proposed. The fibrous network is finally reconstructed by dilating single fibers according to the DT values. Based on the traced single fibers, various morphology information regarding fiber length, radius, orientation, and tortuosity are quantitatively analyzed and compared with our previous results (Wang et al., 2013). Moreover, the number of bonds per fibers are firstly accessed. The methodology described in this paper can be expanded to other fibrous materials with adapted parameters.

  18. Customer Dissatisfaction Index and its Improvement Costs

    NASA Astrophysics Data System (ADS)

    Lvovs, Aleksandrs; Mutule, Anna

    2010-01-01

    The paper gives description of customer dissatisfaction index (CDI) that can be used as reliability level characterizing factor. The factor is directly joined with customer satisfaction of power supply and can be used for control of reliability level of power supply for residential customers. CDI relations with other reliability indices are shown. Paper also gives a brief overview of legislation of Latvia in power industry that is the base for CDI introduction. Calculations of CDI improvement costs are performed in the paper too.

  19. Validation of a scenario-based assessment of critical thinking using an externally validated tool.

    PubMed

    Buur, Jennifer L; Schmidt, Peggy; Smylie, Dean; Irizarry, Kris; Crocker, Carlos; Tyler, John; Barr, Margaret

    2012-01-01

    With medical education transitioning from knowledge-based curricula to competency-based curricula, critical thinking skills have emerged as a major competency. While there are validated external instruments for assessing critical thinking, many educators have created their own custom assessments of critical thinking. However, the face validity of these assessments has not been challenged. The purpose of this study was to compare results from a custom assessment of critical thinking with the results from a validated external instrument of critical thinking. Students from the College of Veterinary Medicine at Western University of Health Sciences were administered a custom assessment of critical thinking (ACT) examination and the externally validated instrument, California Critical Thinking Skills Test (CCTST), in the spring of 2011. Total scores and sub-scores from each exam were analyzed for significant correlations using Pearson correlation coefficients. Significant correlations between ACT Blooms 2 and deductive reasoning and total ACT score and deductive reasoning were demonstrated with correlation coefficients of 0.24 and 0.22, respectively. No other statistically significant correlations were found. The lack of significant correlation between the two examinations illustrates the need in medical education to externally validate internal custom assessments. Ultimately, the development and validation of custom assessments of non-knowledge-based competencies will produce higher quality medical professionals.

  20. Process evaluation of a food marketing and environmental change intervention in Tiendas that serve Latino immigrants in North Carolina.

    PubMed

    Baquero, Barbara; Linnan, Laura; Laraia, Barbara A; Ayala, Guadalupe X

    2014-11-01

    This article describes a comprehensive process evaluation of an efficacious store-based intervention that increased store customers' fruit and vegetable consumption. The process evaluation plan was designed at study inception and implemented at baseline, during the intervention, and at immediate postintervention. Four Latino food stores were randomly assigned either to an intervention or to a control condition. Data were collected from store managers, employees, and 139 Latino customers. Researchers used manager, employee, and customer interviews; weekly observations of the store environment; and implementation logs to assess reach, dose delivered, dose received, and fidelity. Results indicated that it is possible to reach customers in a store-based intervention. Indicators of dose delivered demonstrated that the intervention was implemented as planned, and in the case of employee training, it exceeded the plan. Dose received data indicated that customers moderately engaged with the intervention activities. Together these suggest that the intervention was delivered with good fidelity. Comprehensive process evaluation efforts can facilitate the identification and elimination of barriers to implementation. This approach can serve as a model for future store-based interventions. The study demonstrated that it is feasible to implement Latino food store-based interventions to increase access to and consumption of fruits and vegetables. © 2014 Society for Public Health Education.

  1. Construction of Traceability System for Quality Safety of Cereal and Oil Products

    NASA Astrophysics Data System (ADS)

    Zheng, Huoguo; Liu, Shihong; Meng, Hong; Hu, Haiyan

    After several significant food safety incident, global food industry and governments in many countries are putting increasing emphasis on establishment of food traceability systems. Food traceability has become an effective way in food quality and safety management. The traceability system for quality safety of cereal and oil products was designed and implemented with HACCP and FMECA method, encoding, information processing, and hardware R&D technology etc, according to the whole supply chain of cereal and oil products. Results indicated that the system provide not only the management in origin, processing, circulating and consuming for enterprise, but also tracing service for customers and supervisor by means of telephone, internet, SMS, touch machine and mobile terminal.

  2. Early results from the Array of Things

    NASA Astrophysics Data System (ADS)

    Jacob, R. L.; Catlett, C.; Beckman, P. H.; Sankaran, R.

    2017-12-01

    The Array of Things (AoT) is an experimental sensor and edge-computing network being deployed in the City of Chicago. An AoT node contains sensors for temperature, pressure, humidty and several trace gases as well as 4-core CPU and full Linux operating system. Custom software called "Waggle" controls the hardware and provides the data collection and transmission services. Each node is attached to a traffic signal light and has power 24/7. Data is sent over the cellular network in near realtime. With Chicago's Department of Transportation, we have been making test deployments of AoT nodes, evaluating their capabilities and comparing collected data with that from other observing systems in the Chicago area.

  3. 77 FR 58424 - Self-Regulatory Organizations; International Securities Exchange, LLC; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-20

    ... Priority Customer complex orders that they send to the Exchange in these symbols. In the Select Symbols, the Exchange currently provides a base rebate of $0.34 per contract, per leg, for Priority Customer complex orders when these orders trade with non-Priority Customer complex orders in the complex order book...

  4. Customer and Market Orientation within AACSB Member Business Schools: Comparative Views from Three Levels of Administrators

    ERIC Educational Resources Information Center

    Webster, Robert L.; Hammond, Kevin L.; Rothwell, James C.

    2010-01-01

    This paper is part of a stream of research dealing with customer and market orientation within higher education, specifically within business schools holding membership in AACSB-International. A market orientation strategy leading to a customer and market-oriented organizational culture is based upon the acceptance and adoption of the marketing…

  5. Perceived Status and Value: The Student-Customer Relationship Inflected by the Inherent Challenges of University-Industry Collaboration

    ERIC Educational Resources Information Center

    Heikkinen, Juho; Isomöttönen, Ville

    2017-01-01

    This article examines how students in a multidisciplinary project-based learning course involving real customers perceive their interactions with their customers. The authors conducted a qualitative study and analysed students' learning reports by means of a thematic network analysis. The analysis shows how students perceive their status in…

  6. Applying Customer Dissatisfaction Measures to Schools: You Better Know What's Wrong before You Try To Fix It.

    ERIC Educational Resources Information Center

    Salisbury, David F.; Branson, Robert K.; Altreche, Wanda I.; Funk, Fanchon F.; Broetzmann, Scott M.

    1997-01-01

    Addresses the feasibility of applying customer-dissatisfaction measures to public schools. Presents a framework for a public education customer-satisfaction system, based on the author's previous experience in business and industry. A Florida survey showed that about one-third of parents and two-thirds of businesses were dissatisfied with the…

  7. Creating customer-oriented employees: the case in home health care.

    PubMed

    Hoffman, K D; Ingram, T N

    1991-06-01

    Little empirical research has examined the organizational factors that influence the extent to which health care providers engage in customer-oriented behaviors. The authors examine the influence of role ambiguity, role conflict, and job satisfaction on the customer-oriented behaviors of home health care representatives. Managerial implications based on the study findings are discussed.

  8. Cities through the Prism of People's Spending Behavior.

    PubMed

    Sobolevsky, Stanislav; Sitko, Izabela; Tachet des Combes, Remi; Hawelka, Bartosz; Murillo Arias, Juan; Ratti, Carlo

    2016-01-01

    Scientific studies of society increasingly rely on digital traces produced by various aspects of human activity. In this paper, we exploit a relatively unexplored source of data-anonymized records of bank card transactions collected in Spain by a big European bank, and propose a new classification scheme of cities based on the economic behavior of their residents. First, we study how individual spending behavior is qualitatively and quantitatively affected by various factors such as customer's age, gender, and size of his/her home city. We show that, similar to other socioeconomic urban quantities, individual spending activity exhibits a statistically significant superlinear scaling with city size. With respect to the general trends, we quantify the distinctive signature of each city in terms of residents' spending behavior, independently from the effects of scale and demographic heterogeneity. Based on the comparison of city signatures, we build a novel classification of cities across Spain in three categories. That classification exhibits a substantial stability over different city definitions and connects with a meaningful socioeconomic interpretation. Furthermore, it corresponds with the ability of cities to attract foreign visitors, which is a particularly remarkable finding given that the classification was based exclusively on the behavioral patterns of city residents. This highlights the far-reaching applicability of the presented classification approach and its ability to discover patterns that go beyond the quantities directly involved in it.

  9. Preliminary studies of a simultaneous PET/MRI scanner based on the RatCAP small animal tomograph

    NASA Astrophysics Data System (ADS)

    Woody, C.; Schlyer, D.; Vaska, P.; Tomasi, D.; Solis-Najera, S.; Rooney, W.; Pratte, J.-F.; Junnarkar, S.; Stoll, S.; Master, Z.; Purschke, M.; Park, S.-J.; Southekal, S.; Kriplani, A.; Krishnamoorthy, S.; Maramraju, S.; O'Connor, P.; Radeka, V.

    2007-02-01

    We are developing a scanner that will allow simultaneous acquisition of high resolution anatomical data using magnetic resonance imaging (MRI) and quantitative physiological data using positron emission tomography (PET). The approach is based on the technology used for the RatCAP conscious small animal PET tomograph which utilizes block detectors consisting of pixelated arrays of LSO crystals read out with matching arrays of avalanche photodiodes and a custom-designed ASIC. The version of this detector used for simultaneous PET/MRI imaging will be constructed out of all nonmagnetic materials and will be situated inside the MRI field. We have demonstrated that the PET detector and its electronics can be operated inside the MRI, and have obtained MRI images with various detector components located inside the MRI field. The MRI images show minimal distortion in this configuration even where some components still contain traces of certain magnetic materials. We plan to improve on the image quality in the future using completely non-magnetic components and by tuning the MRI pulse sequences. The combined result will be a highly compact, low mass PET scanner that can operate inside an MRI magnet without distorting the MRI image, and can be retrofitted into existing MRI instruments.

  10. Recent advances of mid-infrared compact, field deployable sensors: principles and applications

    NASA Astrophysics Data System (ADS)

    Tittel, Frank; Gluszek, Aleksander; Hudzikowski, Arkadiusz; Dong, Lei; Li, Chunguang; Patimisco, Pietro; Sampaolo, Angelo; Spagnolo, Vincenzo; Wojtas, Jacek

    2016-04-01

    The recent development of compact interband cascade lasers(ICLs) and quantum cascade lasers (QCLs) based trace gas sensors will permit the targeting of strong fundamental rotational-vibrational transitions in the mid-infrared which are one to two orders of magnitude more intense than transitions in the overtone and combination bands in the near-infrared. This has led to the design and fabrication of mid-infrared compact, field deployable sensors for use in the petrochemical industry, environmental monitoring and atmospheric chemistry. Specifically, the spectroscopic detection and monitoring of four molecular species, methane (CH4) [1], ethane (C2H6), formaldehyde (H2CO) [2] and hydrogen sulphide (H2S) [3] will be described. CH4, C2H6 and H2CO can be detected using two detection techniques: mid-infrared tunable laser absorption spectroscopy (TDLAS) using a compact multi-pass gas cell and quartz enhanced photoacoustic spectroscopy (QEPAS). Both techniques utilize state-of-the-art mid-IR, continuous wave (CW), distributed feedback (DFB) ICLs and QCLs. TDLAS was performed with an ultra-compact 54.6m effective optical path length innovative spherical multipass gas cell capable of 435 passes between two concave mirrors separated by 12.5 cm. QEPAS used a small robust absorption detection module (ADM) which consists of a quartz tuning fork (QTF), two optical windows, gas inlet/outlet ports and a low noise frequency pre-amplifier. Wavelength modulation and second harmonic detection were employed for spectral data processing. TDLAS and QEPAS can achieve minimum detectable absorption losses in the range from 10-8 to 10-11cm-1/Hz1/2. Several recent examples of real world applications of field deployable gas sensors will be described. For example, an ICL based TDLAS sensor system is capable of detecting CH4 and C2H6 concentration levels of 1 ppb in a 1 sec. sampling time, using an ultra-compact, robust sensor architecture. H2S detection was realized with a THz QEPAS sensor system using a custom quartz tuning fork (QTF) with a new geometry and a QCL emitting at 2.913 THz [4]. Furthermore, two new approaches aimed to achieve enhanced detection sensitivities with QEPAS based sensing can be realized. The first method will make use of a compact optical power buildup cavity, which achieves significantly lower minimum detectable trace gas concentration levels of < 10 pptv. The second approach will use custom fabricated QTFs capable of improved detection sensitivity. Acknowledgements F.K. Tittel acknowledges support by the National Science Foundation (NSF) ERC MIRTHE award, the Robert Welch Foundation (Grant C-0586) and DOE ARPA-E Monitor Proram. L. Dong acknowledges support by NSF-China (Grant #s. 61275213, 61108030), J. Wojtas acknowledges support by The National Centre for Research and Development, Poland (project ID: 179616). References [1] L. Dong, C. Li, N. P. Sanchez, A. K. Gluszek, R. Griffin and F. K. Tittel;" Compact CH4 sensor system based on a continuous-wave, low power consumption, room temperature interband cascade laser", Appl. Phys Lett. 108, 011106 (2016). [2] L. Dong, Y. Yu, C. Li, S. So, and F.K. Tittel, "Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass cell" Optics Express; 23, 19821-19830 (2015). [3] V. Spagnolo, P. Patimisco, R. Pennetta, A. Sampaolo, G. Scamarcio, M. Vitiello, and F.K. Tittel, "THz Quartz-enhanced photoacoustic sensor for H2S trace gas detection", Opt. Exp. 23, 7574-7582 (2015). [4] A. Sampaolo, P. Patimisco, L. Dong , A. Geras, S, G. Scamarcio' T. Starecki, F.K Tittel, V. Spagnolo; "Quartz-Enhanced Photoacoustic Spectroscopy exploiting tuning fork overtone modes", Appl. Phys Lett. 107, 231102 (2015).

  11. Do Librarians Really Do That? Or Providing Custom, Fee-Based Services.

    ERIC Educational Resources Information Center

    Whitmore, Susan; Heekin, Janet

    This paper describes some of the fee-based, custom services provided by National Institutes of Health (NIH) Library to NIH staff, including knowledge management, clinical liaisons, specialized database searching, bibliographic database development, Web resource guide development, and journal management. The first section discusses selecting the…

  12. 77 FR 4993 - Certain Frozen Warmwater Shrimp From the Socialist Republic of Vietnam: Initiation and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ..., management, supplier relationships, and customer base). In its December 13, 2011, submission, C. P. Vietnam... including, but not limited to, changes in management, production facilities, supplier relationships, and customer base.\\8\\ Although no single factor will necessarily provide a dispositive indication of succession...

  13. Custom therapeutic insoles based on both foot shape and plantar pressure measurement provide enhanced pressure relief.

    PubMed

    Owings, Tammy M; Woerner, Julie L; Frampton, Jason D; Cavanagh, Peter R; Botek, Georgeanne

    2008-05-01

    The purpose of this study was to determine whether custom insoles tailored to contours of the barefoot pressure distribution and shape of a patient's foot can reduce plantar pressures in the metatarsal head (MTH) region to a greater extent than conventional custom insoles. Seventy regions of elevated barefoot pressures (mean peak 834 kPa under MTHs) were identified in 20 subjects with diabetes. Foam box impressions of their feet were sent to three different orthotic supply companies for fabrication of custom insoles. One company was also given plantar pressure data, which were incorporated into the insole design. Measurements of in-shoe plantar pressures were recorded during gait for the three custom insoles in a flexible and a rocker-bottom shoe. Peak pressure and force-time integral were extracted for analysis. In 64 of 70 regions, the shape-plus-pressure-based insole in the flexible shoe achieved superior unloading compared with the two shape-based insoles. On average, peak pressure was reduced by 32 and 21% (both P

  14. A store-based intervention to increase fruit and vegetable consumption: The El Valor de Nuestra Salud cluster randomized controlled trial

    PubMed Central

    Ayala, Guadalupe X.; Baquero, Barbara; Pickrel, Julie L.; Mayer, Joni; Belch, George; Rock, Cheryl L.; Linnan, Laura; Gittelsohn, Joel; Sanchez-Flack, Jennifer; Elder, John P.

    2015-01-01

    Introduction Most evidence-based interventions to improve fruit and vegetable (FV) consumption target individual behaviors and family systems; however, these changes are difficult to sustain without environmental support. This paper describes an innovative social and structural food store-based intervention to increase availability and accessibility of FVs in tiendas (small-to medium-sized Latino food stores) and purchasing and consumption of FVs among tienda customers. Methods Using a cluster randomized controlled trial with 16 tiendas pair-matched and randomized to an intervention or wait-list control condition, this study will evaluate a 2-month intervention directed at tiendas, managers, and employees followed by a 4-month customer-directed food marketing campaign. The intervention involves social (e.g., employee trainings) and structural (e.g., infrastructure) environmental changes. Three hundred sixty-nine customers (approximately 23 per tienda) serve on an evaluation cohort and complete assessments (interviews and measurements of weight) at 3 time points: baseline, 6-months post-baseline, and 12-months post-baseline. The primary study outcome is customer-reported daily consumption of FVs. Manager interviews and monthly tienda audits and collection of sales data will provide evidence of tienda-level intervention effects, our secondary outcomes. Process evaluation methods assess dose delivered, dose received, and fidelity. Results Recruitment of tiendas, managers, employees, and customers is complete. Demographic data shows that 30% of the customers are males, thus providing a unique opportunity to examine the effects of a tienda-based intervention on Latino men. Conclusions Determining whether a tienda-based intervention can improve customers’ FV purchasing and consumption will provide key evidence for how to create healthier consumer food environments. PMID:25924592

  15. Knowledge discovery from patients' behavior via clustering-classification algorithms based on weighted eRFM and CLV model: An empirical study in public health care services.

    PubMed

    Zare Hosseini, Zeinab; Mohammadzadeh, Mahdi

    2016-01-01

    The rapid growing of information technology (IT) motivates and makes competitive advantages in health care industry. Nowadays, many hospitals try to build a successful customer relationship management (CRM) to recognize target and potential patients, increase patient loyalty and satisfaction and finally maximize their profitability. Many hospitals have large data warehouses containing customer demographic and transactions information. Data mining techniques can be used to analyze this data and discover hidden knowledge of customers. This research develops an extended RFM model, namely RFML (added parameter: Length) based on health care services for a public sector hospital in Iran with the idea that there is contrast between patient and customer loyalty, to estimate customer life time value (CLV) for each patient. We used Two-step and K-means algorithms as clustering methods and Decision tree (CHAID) as classification technique to segment the patients to find out target, potential and loyal customers in order to implement strengthen CRM. Two approaches are used for classification: first, the result of clustering is considered as Decision attribute in classification process and second, the result of segmentation based on CLV value of patients (estimated by RFML) is considered as Decision attribute. Finally the results of CHAID algorithm show the significant hidden rules and identify existing patterns of hospital consumers.

  16. Knowledge discovery from patients’ behavior via clustering-classification algorithms based on weighted eRFM and CLV model: An empirical study in public health care services

    PubMed Central

    Zare Hosseini, Zeinab; Mohammadzadeh, Mahdi

    2016-01-01

    The rapid growing of information technology (IT) motivates and makes competitive advantages in health care industry. Nowadays, many hospitals try to build a successful customer relationship management (CRM) to recognize target and potential patients, increase patient loyalty and satisfaction and finally maximize their profitability. Many hospitals have large data warehouses containing customer demographic and transactions information. Data mining techniques can be used to analyze this data and discover hidden knowledge of customers. This research develops an extended RFM model, namely RFML (added parameter: Length) based on health care services for a public sector hospital in Iran with the idea that there is contrast between patient and customer loyalty, to estimate customer life time value (CLV) for each patient. We used Two-step and K-means algorithms as clustering methods and Decision tree (CHAID) as classification technique to segment the patients to find out target, potential and loyal customers in order to implement strengthen CRM. Two approaches are used for classification: first, the result of clustering is considered as Decision attribute in classification process and second, the result of segmentation based on CLV value of patients (estimated by RFML) is considered as Decision attribute. Finally the results of CHAID algorithm show the significant hidden rules and identify existing patterns of hospital consumers. PMID:27610177

  17. Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) from an Unmanned Aerial Vehicle (UAV): Results from the 2014 AROMAT campaign

    NASA Astrophysics Data System (ADS)

    Merlaud, Alexis; Tack, Frederik; Constantin, Daniel; Fayt, Caroline; Maes, Jeroen; Mingireanu, Florin; Mocanu, Ionut; Georgescu, Lucian; Van Roozendael, Michel

    2015-04-01

    The Small Whiskbroom Imager for atmospheric compositioN monitorinG (SWING) is an instrument dedicated to atmospheric trace gas retrieval from an Unmanned Aerial Vehicle (UAV). The payload is based on a compact visible spectrometer and a scanning mirror to collect scattered sunlight. Its weight, size, and power consumption are respectively 920 g, 27x12x12 cm3, and 6 W. The custom-built 2.5 m flying wing UAV is electrically powered, has a typical airspeed of 100 km/h, and can operate at a maximum altitude of 3 km. Both the payload and the UAV were developed in the framework of a collaboration between the Belgian Institute for Space Aeronomy (BIRA-IASB) and the Dunarea de Jos University of Galati, Romania. We present here SWING-UAV test flights dedicated to NO2 measurements and performed in Romania on 10 and 11 September 2014, during the Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaign. The UAV performed 5 flights in the vicinity of the large thermal power station of Turceni (44.67° N, 23.4° E). The UAV was operated in visual range during the campaign, up to 900 m AGL , downwind of the plant and crossing its exhaust plume. The spectra recorded on flight are analyzed with the Differential Optical Absorption Spectroscopy (DOAS) method. The retrieved NO2 Differential Slant Column Densities (DSCDs) are up to 1.5e17 molec/cm2 and reveal the horizontal gradients around the plant. The DSCDs are converted to vertical columns and compared with coincident car-based DOAS measurements. We also present the near-future perspective of the SWING-UAV observation system, which includes flights in 2015 above the Black Sea to quantify ship emissions, the addition of SO2 as a target species, and autopilot flights at higher altitudes to cover a typical satellite pixel extent (10x10 km2).

  18. EpiContactTrace: an R-package for contact tracing during livestock disease outbreaks and for risk-based surveillance.

    PubMed

    Nöremark, Maria; Widgren, Stefan

    2014-03-17

    During outbreak of livestock diseases, contact tracing can be an important part of disease control. Animal movements can also be of relevance for risk-based surveillance and sampling, i.e. both when assessing consequences of introduction or likelihood of introduction. In many countries, animal movement data are collected with one of the major objectives to enable contact tracing. However, often an analytical step is needed to retrieve appropriate information for contact tracing or surveillance. In this study, an open source tool was developed to structure livestock movement data to facilitate contact-tracing in real time during disease outbreaks and for input in risk-based surveillance and sampling. The tool, EpiContactTrace, was written in the R-language and uses the network parameters in-degree, out-degree, ingoing contact chain and outgoing contact chain (also called infection chain), which are relevant for forward and backward tracing respectively. The time-frames for backward and forward tracing can be specified independently and search can be done on one farm at a time or for all farms within the dataset. Different outputs are available; datasets with network measures, contacts visualised in a map and automatically generated reports for each farm either in HTML or PDF-format intended for the end-users, i.e. the veterinary authorities, regional disease control officers and field-veterinarians. EpiContactTrace is available as an R-package at the R-project website (http://cran.r-project.org/web/packages/EpiContactTrace/). We believe this tool can help in disease control since it rapidly can structure essential contact information from large datasets. The reproducible reports make this tool robust and independent of manual compilation of data. The open source makes it accessible and easily adaptable for different needs.

  19. Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bird, Lori; Davidson, Carolyn; McLaren, Joyce

    With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset,more » on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.« less

  20. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen

    2011-06-01

    Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers inmore » the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.« less

Top