Sample records for cvp operating point

  1. Evidence for central venous pressure resetting during initial exposure to microgravity

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Ludwig, D. A.; Elliott, J. J.; Wade, C. E.

    2001-01-01

    We measured central venous pressure (CVP); plasma volume (PV); urine volume rate (UVR); renal excretion of sodium (UNa); and renal clearances of creatinine, sodium, and osmolality before and after acute volume infusion to test the hypothesis that exposure to microgravity causes resetting of the CVP operating point. Six rhesus monkeys underwent two experimental conditions in a crossover counterbalance design: 1) continuous exposure to 10 degrees head-down tilt (HDT) and 2) a control, defined as 16 h/day of 80 degrees head-up tilt and 8 h prone. After 48 h of exposure to either test condition, a 120-min course of continuous infusion of isotonic saline (0.4 ml. kg(-1). min(-1) iv) was administered. Baseline CVP was lower (P = 0.011) in HDT (2.3 +/- 0.3 mmHg) compared with the control (4.5 +/- 1.4 mmHg) condition. After 2 h of saline infusion, CVP was elevated (P = 0.002) to a similar magnitude (P = 0.485) in HDT (DeltaCVP = 2.7 +/- 0.8 mmHg) and control (DeltaCVP = 2.3 +/- 0.8 mmHg) conditions and returned to preinfusion levels 18 h postinfusion in both treatments. PV followed the same pattern as CVP. The response relationships between CVP and UVR and between CVP and UNa shifted to the left with HDT. The restoration of CVP and PV to lower preinfusion levels after volume loading in HDT compared with control supports the notion that lower CVP during HDT may reflect a new operating point about which vascular volume is regulated. These results may explain the ineffective fluid intake procedures currently employed to treat patients and astronauts.

  2. Is there resetting of central venous pressure in microgravity?

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Ludwig, D. A.; Elliott, J. J.; Wade, C. E.

    2001-01-01

    In the early phase of the Space Shuttle program, NASA flight surgeons implemented a fluid-loading countermeasure in which astronauts were instructed to ingest eight 1-g salt tablets with 960 ml of water approximately 2 hours prior to reentry from space. This fluid loading regimen was intended to enhance orthostatic tolerance by replacing circulating plasma volume reduced during the space mission. Unfortunately, fluid loading failed to replace plasma volume in groundbased experiments and has proven minimally effective as a countermeasure against post-spaceflight orthostatic intolerance. In addition to the reduction of plasma volume, central venous pressure (CVP) is reduced during exposure to actual and groundbased analogs of microgravity. In the present study, we hypothesized that the reduction in CVP due to exposure to microgravity represents a resetting of the CVP operating point to a lower threshold. A lower CVP 'setpoint' might explain the failure of fluid loading to restore plasma volume. In order to test this hypothesis, we conducted an investigation in which we administered an acute volume load (stimulus) and measured responses in CVP, plasma volume and renal functions. If our hypothesis is true, we would expect the elevation in CVP induced by saline infusion to return to its pre-infusion levels in both HDT and upright control conditions despite lower vascular volume during HDT. In contrast to previous experiments, our approach is novel in that it provides information on alterations in CVP and vascular volume during HDT that are necessary for interpretation of the proposed CVP operating point resetting hypothesis.

  3. Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.

    1995-01-01

    Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

  4. Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.

    1996-01-01

    Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

  5. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation.

    PubMed

    Shojaee, Majid; Sabzghabaei, Anita; Alimohammadi, Hossein; Derakhshanfar, Hojjat; Amini, Afshin; Esmailzadeh, Bahareh

    2017-01-01

    Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH 2 O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male). The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH 2 O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH 2 O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH 2 O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039). The relationship between CVP and 5 cmH 2 O (p = 0.279), and 10 cmH 2 O (p = 0.292) PEEP changes were not dependent on the baseline level of CVP. The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH 2 O increase in PEEP will be associated with about 2.5 cmH 2 O raise in CVP. When applying a 5 cmH 2 O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH 2 O (2.5 vs. 1.6). It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  6. [Measurement of the evaluative capacity of the CVP-35 questionnaire for perceiving the quality of professional life].

    PubMed

    Martín Fernández, Jesús; Gómez Gascón, Tomás; Martínez García-Olalla, Carlos; del Cura González, María Isabel; Cabezas Peña, María Carmen; García Sánchez, Salvador

    2008-07-01

    To establish the CVP-35 evaluative properties to measure the professional quality of life (PQL). Prospective, observational study. A primary care area in the Community of Madrid, Spain. A total of 149 sanitary workers with some burnout sign measured by Maslach Burnout Inventory (MBI) participated. They fulfilled MBI, Goldberg Health Questionnaire (GHQ-28), and CVP-35 questionnaires at the beginning and after a year of follow-up, in which 73 subjects took part in activities for coping stress. It was assessed the change of PQL and their domains managerial support (PQL-MS), work load (PQL-WL), intrinsic motivation (PQL-IM) for the subjects with variations at the MBI, or GHQ-28 punctuation greater than 0.5 SD of the initial distribution. Variations in CVP-35 and their domains correlate weakly with changes in MBI and GHQ-28 (r<0.500), but they are congruent with the conceptual model. In the individuals with significant variations in the GHQ-28, they appreciate an average change in PQL and their domains between 0.18 and 0.55 points (absolute value). In those with significant variations in the MBI domains, PQL presented average absolute variations between 0.23 and 0.45 points, PQL-MS between 0.30 and 0.67, PQL-WL between 0.01 and 0.55 and PQL-IM between 0.22 and 0.83 points. CVP-35 is a sensitive-to-change instrument under population point of view. Changes in PQL perception or in any of their domains of 0.5 points could be pointed as relevant.

  7. Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial.

    PubMed

    Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo

    2017-08-01

    We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P < .001). Additional post hoc analysis suggested that younger age, lower baseline CVP, and longer duration of milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.

  8. Optimal right heart filling pressure in acute respiratory distress syndrome determined by strain echocardiography.

    PubMed

    Garcia-Montilla, Romel; Imam, Faryal; Miao, Mi; Stinson, Kathryn; Khan, Akram; Heitner, Stephen

    2017-06-01

    Right ventricular (RV) systolic dysfunction is common in acute respiratory distress syndrome (ARDS). While preload optimization is crucial in its management, dynamic fluid responsiveness indices lack reliability, and there is no consensus on target central venous pressure (CVP). We analyzed the utility of RV free wall longitudinal strain (RVFWS) in the estimation of optimal RV filling pressure in ARDS. A retrospective cross-sectional analysis of clinical data and echocardiograms of patients with ARDS was performed. Tricuspid annular plane systolic excursion (TAPSE), tricuspid peak systolic velocity (S'), RV fractional area change (RVFAC), RVFWS, CVP, systolic pulmonary artery pressure (SPAP), and left ventricular ejection fraction (LVEF) were measured. Fifty-one patients with moderate-severe ARDS were included. There were inverse correlations between CVP and TAPSE, S', RVFAC, RVFWS, and LVEF. The most significant was with RVFWS (r:.74, R 2 :.55, P:.00001). Direct correlations with creatinine and lactate were noted. Receiver operating characteristic analysis showed that RVFWS -21% (normal reference value) was associated with CVP: 13 mm Hg (AUC: 0.92, 95% CI: 0.83-1.00). Regression model analysis of CVP, and RVFWS interactions established an RVFWS range from -18% to -24%. RVFWS -24% corresponded to CVP: 11 mm Hg and RVFWS -18% to CVP: 15 mm Hg. Beyond a CVP of 15 mm Hg, biventricular systolic dysfunction rapidly ensues. Our data are the first to show that an RV filling pressure of 13±2 mm Hg-as by CVP-correlates with optimal RV mechanics as evaluated by strain echocardiography in patients with moderate-severe ARDS. © 2017, Wiley Periodicals, Inc.

  9. 76 FR 56905 - The Central Valley Project, the California-Oregon Transmission Project, the Pacific Alternating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... capability of each transmission system and the costs that support the generation capability of the CVP system...) operates the water control and delivery system and all of the power plants with the exception of the San... existing formula rate methodologies for power; CVP, COTP, and PACI transmission; transmission of Western...

  10. Fibre-grating sensors for the measurement of physiological pulsations

    NASA Astrophysics Data System (ADS)

    Petrović, M. D.; Daničić, A.; Atanasoski, V.; Radosavljević, S.; Prodanović, V.; Miljković, N.; Petrović, J.; Petrović, D.; Bojović, B.; Hadžievski, Lj; Allsop, T.; Lloyd, G.; Webb, D. J.

    2013-11-01

    Mechanical physiological pulsations are movements of a body surface incited by the movements of muscles in organs inside the body. Here we demonstrate the use of long-period grating sensors in the detection of cardio-vascular pulsations (CVP), in particular apex and carotid pulsations. To calibrate the sensors, we use a mechanical tool designed specifically to measure the sensor response to a localized perturbation at different grating curvatures as working points. From the data we infer the amplitude of the CVP. Together with the electrophysiological signals, the CVP signals obtained from the sensors can provide significant information on heart function which is inaccessible to the electrocardiogram. The low cost and easy handling of the fibre sensors increase their prospects to become the sensors of choice for novel diagnostic devices.

  11. Low central venous pressure with milrinone during living donor hepatectomy.

    PubMed

    Ryu, H-G; Nahm, F S; Sohn, H-M; Jeong, E-J; Jung, C-W

    2010-04-01

    Maintaining a low central venous pressure (CVP) has been frequently used in liver resections to reduce blood loss. However, decreased preload carries potential risks such as hemodynamic instability. We hypothesized that a low CVP with milrinone would provide a better surgical environment and hemodynamic stability during living donor hepatectomy. Thirty-eight healthy adult liver donors were randomized to receive either milrinone (milrinone group, n = 19) or normal saline (control group, n = 19) infusion during liver resection. The surgical field was assessed using a four-point scale. Intraoperative vital signs, blood loss, the use of vasopressors and diuretics and postoperative laboratory data were compared between groups. The milrinone group showed a superior surgical field (p < 0.001) and less blood loss (142 +/- 129 mL vs. 378 +/- 167 mL, p < 0.001). Vital signs were well maintained in both groups but the milrinone group required smaller amounts of vasopressors and less-frequent diuretics to maintain a low CVP. The milrinone group also showed a more rapid recovery pattern after surgery. Milrinone-induced low CVP improves the surgical field with less blood loss during living donor hepatectomy and also has favorable effects on intraoperative hemodynamics and postoperative recovery.

  12. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    PubMed

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  13. Coriolus versicolor mushroom polysaccharides exert immunoregulatory effects on mouse B cells via membrane Ig and TLR-4 to activate the MAPK and NF-κB signaling pathways.

    PubMed

    Yang, Shu-fa; Zhuang, Tai-feng; Si, Yan-mei; Qi, Ke-yan; Zhao, Juan

    2015-03-01

    This study aimed to characterize the immunopotentiating effects and immune receptors for Coriolus versicolor mushroom polysaccharides (CVP), a Chinese medicinal fungus that exerts anti-tumor activities by enhancing host immunity. Proliferation assays were used to determine whether CVP could activate splenocytes. Flow cytometry analysis and IgM and IgG detection were used to characterize CVP-binding cells. Immune receptors were analyzed in immunoprecipitation and western blot assays. The downstream signaling pathways were identified by western blotting or immunostaining. CVP significantly stimulated the proliferation of mouse splenocytes. Fluorescence-labeled CVP (fl-CVP) selectively stained mouse B cells, but not T cells. CVP induced the production of IgM and IgG1 with or without exogenous IL-4. Membrane Ig (B cell antigen-receptor, BCR) was identified as a CVP-binding protein in immunoprecipitation and western blot experiments. CVP-induced B cell proliferation could be significantly inhibited by anti-mouse immunoglobulin (Ig) blocking antibody (Fab) or in cells from TLR4-mutant mice (C3H/HeJ). Phosphorylation of ERK-1/2 and p38 MAPK were clearly increased in a time-dependent manner, as was the nuclear translocation of the cytosolic NF-κB p65 subunit after CVP stimulation. Together, we demonstrate that CVP can bind and induce B cell activation using membrane Ig and TLR-4 as potential immune receptors. CVP activates mouse B cells through the MAPK and NF-κB signaling pathways. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Scenario Planning of California Water Resources with Climate Change

    NASA Astrophysics Data System (ADS)

    Yin, H.; Chung, F. I.; Anderson, J.

    2008-12-01

    Several advances have been made in using climate change projection information in water resources planning in California. Since there is uncertainty about future climate, 12 climate change projections were used to assess impacts on SWP and CVP operations. Average results for the 12 projections are presented in this summary. Current SWP and CVP infrastructure, regulations and operating rules were assumed. These studies indicate that climate change is expected to reduce the reliability of the SWP and CVP water supply systems. Annual Delta exports are expected to be reduced by 8% by mid-century and 15% by the end of the century. This would lead to reduced water deliveries south of the Delta. Decreases in reservoir carryover storage of 16% by mid-century and 28% by the end of the century would reduce the system's flexibility during water shortages. Groundwater pumping in the Sacramento Valley is expected to increase by 8% by mid-century and by 13% at the end of the century to augment surface water supplies. Power supply from the combined SWP and CVP is expected to decrease by 5% at mid-century and 8% by the end of the century. It is anticipated that the SWP and CVP will become vulnerable to operational interruption in about 10% of the years by mid-century and 15% of the years at the end of the century. To meet current regulatory requirements and to maintain minimum system operations during the vulnerable years, an additional 420 TAF/year of water by mid-century and an additional 610 TAF/year of water by the end of the century would be needed. This water could be obtained through additional water supplies, reductions in water demands, or a combination of the two. These results indicate a need to explore adaptation measures to improve the reliability of future water supplies in California. Because uncertainties associated with impacts analyses increase as the projection moves further into the future, and because a practical engineering planning horizon for most facilities is less than 50 years, DWR believes that the mid-century analyses are more relevant to water resources planning and management. However, the end of the century analyses will serve as a useful reference guide since many water facilities are expected to have useful lives into the next century.

  15. Circulatory filling pressures during transient microgravity induced by parabolic flight

    NASA Technical Reports Server (NTRS)

    Latham, Ricky D.; Fanton, John W.; White, C. D.; Vernalis, Mariana N.; Crisman, R. P.; Koenig, S. C.

    1993-01-01

    Theoretical concepts hold that blood in the gravity dependent portion of the body would relocate to more cephalad compartments under microgravity. The result is an increase in blood volume in the thoraic and cardiac chambers. However, experimental data has been somewhat contradictory and nonconclusive. Early studies of peripheral venous pressure and estimates of central venous pressure (CVP) from these data did not show an increase in CVP under microgravity. However, CVP recorded in human volunteers during a parabolic flight revealed an increase in CVP during the microgravity state. On the STS 40 shuttle mission, a payload specialist wore a fluid line that recorded CVP during the first few hours of orbital insertion. These data revealed decreased CVP. When this CVP catheter was tested during parabolic flight in four subjects, two had increased CVP recordings and two had decreased CVP measurements. In 1991, our laboratory performed parabolic flight studies in several chronic-instrumented baboons. It was again noted that centrally recorded right atrial pressure varied with exposure to microgravity, some animals having an increase, and others a decrease.

  16. Transoesophageal Doppler compared to central venous pressure for perioperative hemodynamic monitoring and fluid guidance in liver resection.

    PubMed

    El Sharkawy, Osama A; Refaat, Emad K; Ibraheem, Abdel Elmoniem M; Mahdy, Wafiya R; Fayed, Nirmeen A; Mourad, Wesam S; Abd Elhafez, Hanaa S; Yassen, Khaled A

    2013-10-01

    Major hepatic resections may result in hemodynamic changes. Aim is to study transesophageal Doppler (TED) monitoring and fluid management in comparison to central venous pressure (CVP) monitoring. A follow-up comparative hospital based study. 59 consecutive cirrhotic patients (CHILD A) undergoing major hepatotomy. CVP monitoring only (CVP group), (n=30) and TED (Doppler group), (n=29) with CVP transduced but not available on the monitor. Exclusion criteria include contra-indication for Doppler probe insertion or bleeding tendency. An attempt to reduce CVP during the resection in both groups with colloid restriction, but crystalloids infusion of 6 ml/kg/h was allowed to replace insensible loss. Post-resection colloids infusion were CVP guided in CVP group (5-10 mmHg) and corrected flow time (FTc) aortic guided in Doppler group (>0.4 s) blood products given according to the laboratory data. Using the FTc to guide Hydroxyethyl starch 130/0.4 significantly decreased intake in TED versus CVP (1.03 [0.49] versus 1.74 [0.41] Liter; P<0.05). Nausea, vomiting, and chest infection were less in TED with a shorter hospital stay (P<0.05). No correlation between FTc and CVP (r=0.24, P > 0.05). Cardiac index and stroke volume of TED increased post-resection compared to baseline, 3.0 (0.9) versus 3.6 (0.9) L/min/m(2), P<0.05; 67.1 (14.5) versus 76 (13.2) ml, P<0.05, respectively, associated with a decrease in systemic vascular resistance (SVR) 1142.7 (511) versus 835.4 (190.9) dynes.s/cm(5), P<0.05. No significant difference in arterial pressure and CVP between groups at any stage. CVP during resection in TED 6.4 (3.06) mmHg versus 6.1 (1.4) in CVP group, P=0.6. TED placement consumed less time than CVP (7.3 [1.5] min versus 13.2 [2.9], P<0.05). TED in comparison to the CVP monitoring was able to reduced colloids administration post-resection, lower morbidity and shorten hospital stay. TED consumed less time to insert and was also able to present significant hemodynamic changes. Advanced surgical techniques of resection play a key role in reducing blood loss despite CVP more than 5 cm H2O. TED fluid management protocols during resection need to be developed.

  17. Baroreflex-mediated heart rate and vascular resistance responses 24 h after maximal exercise

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.

    2003-01-01

    INTRODUCTION: Plasma volume, heart rate (HR) variability, and stimulus-response relationships for baroreflex control of forearm vascular resistance (FVR) and HR were studied in eight healthy men after and without performing a bout of maximal exercise to test the hypotheses that acute expansion of plasma volume is associated with 1) reduction in baroreflex-mediated HR response, and 2) altered operational range for central venous pressure (CVP). METHODS: The relationship between stimulus (DeltaCVP) and vasoconstrictive reflex response (DeltaFVR) during unloading of cardiopulmonary baroreceptors was assessed with lower-body negative pressure (LBNP, 0, -5, -10, -15, -20 mm Hg). The relationship between stimulus (Deltamean arterial pressure (MAP)) and cardiac reflex response (DeltaHR) during loading of arterial baroreceptors was assessed with steady-state infusion of phenylephrine (PE) designed to increase MAP by 15 mm Hg alone and during application of LBNP (PE+LBNP) and neck pressure (PE+LBNP+NP). Measurements of vascular volume and autonomic baroreflex responses were conducted on two different test days, each separated by at least 1 wk. On one day, baroreflex response was tested 24 h after graded cycle exercise to volitional exhaustion. On another day, measurement of baroreflex response was repeated with no exercise (control). The order of exercise and control treatments was counterbalanced. RESULTS: Baseline CVP was elevated (P = 0.04) from a control value of 10.5 +/- 0.4 to 12.3 +/- 0.4 mm Hg 24 h after exercise. Average DeltaFVR/DeltaCVP during LBNP was not different (P = 0.942) between the exercise (-1.35 +/- 0.32 pru x mm Hg-1) and control (-1.32 +/- 0.36 pru x mm Hg-1) conditions. However, maximal exercise caused a shift along the reflex response relationship to a higher CVP and lower FVR. HR baroreflex response (DeltaHR/DeltaMAP) to PE+LBNP+NP was lower (P = 0.015) after maximal exercise (-0.43 +/- 0.15 beats x min-1 x mm Hg-1) compared with the control condition (-0.83 +/- 0.14 beats x min-1 x mm Hg-1). CONCLUSION: Expansion of vascular volume after acute exercise is associated with altered operational range for CVP and reduced HR response to arterial baroreceptor stimulation.

  18. Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

    PubMed

    Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri

    2015-11-01

    Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was <10 cmH2O. However, the correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.

  19. Preclinical anti-tumor activity of antibody-targeted chemotherapy with CMC-544 (inotuzumab ozogamicin), a CD22-specific immunoconjugate of calicheamicin, compared with non-targeted combination chemotherapy with CVP or CHOP.

    PubMed

    DiJoseph, John F; Dougher, Maureen M; Evans, Deborah Y; Zhou, Bin-Bing; Damle, Nitin K

    2011-04-01

    CMC-544 (inotuzumab ozogamicin) is a CD22-specific immunoconjugate of calicheamicin currently being evaluated in patients with non-Hodgkin's B-cell lymphoma (BCL). CHOP and CVP represent untargeted combination chemotherapy comprised of cyclophosphamide, vincristine and prednisone with or without doxorubicin, commonly used in the treatment of NHL. Here, we describe anti-tumor efficacy of CMC-544, CHOP or CVP against human BCL xenografts. In vitro, human BCLs were cultured with CMC-544 or individual constituents of CHOP for inhibition of their growth. In vivo, immunocompromised mice with established BCL xenografts were administered CHOP, CVP or CMC-544 to monitor their survival and BCL growth. In vitro, CMC-544 was more potent in causing growth inhibition of various BCL than cyclophosphamide, doxorubicin, vincristine or dexamethasone. In vivo, treatment with CHOP or CVP inhibited growth of BCL xenografts for up to 40 days after which BCL relapsed. Tumor growth inhibition by CMC-544 (>100 days) lasted longer than that by CHOP or CVP. BCL xenografts that relapsed after the treatment with CHOP or CVP were far less responsive to CHOP or CVP re-treatment but regressed upon subsequent treatment with CMC-544. CVP could be co-administered with suboptimal doses of CMC-544, while CHOP could be administered on alternant days with CMC-544 to cause enhanced regression of established BCL xenografts. Preclinically, CMC-544 provides greater therapeutic benefit than CVP or CHOP against BCL xenografts. CMC-544 may also be co-administered with standard chemotherapeutic regimens in the treatment of B-NHL for superior anti-tumor activity.

  20. A Review of Central Venous Pressure and Its Reliability as a Hemodynamic Monitoring Tool in Veterinary Medicine.

    PubMed

    Hutchinson, Kristen M; Shaw, Scott P

    2016-09-01

    To review the current literature regarding central venous pressure (CVP) in veterinary patients pertaining to placement (of central line), measurement, interpretation, use in veterinary medicine, limitations, and controversies in human medicine. CVP use in human medicine is a widely debated topic, as numerous sources have shown poor correlation of CVP measurements to the volume status of a patient. Owing to the ease of placement and monitoring in veterinary medicine, CVP remains a widely used modality for evaluating the hemodynamic status of a patient. A thorough evaluation of the veterinary and human literature should be performed to evaluate the role of CVP measurements in assessing volume status in veterinary patients. Veterinary patients that benefit from accurate CVP readings include those suffering from hypovolemic or septic shock, heart disease, or renal disease or all of these. Other patients that may benefit from CVP monitoring include high-risk anesthetic patients undergoing major surgery, trending of fluid volume status in critically ill patients, patients with continued shock, and patients that require rapid or large amounts of fluids. The goal of CVP use is to better understand a patient's intravascular volume status, which would allow early goal-directed therapy. CVP would most likely continue to play an important role in the hemodynamic monitoring of the critically ill veterinary patient; however, when available, cardiac output methods should be considered the first choice for hemodynamic monitoring. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. [Changes in hemodynamics and oxygen metabolism of different Child-grade patients during orthotopic liver transplantation without veno-venous bypass].

    PubMed

    Zhao, Dong; Wang, Tian-long; Pan, Fang; Zhao, Lei; Zhang, Lian-feng; Yang, Ba-xian

    2006-08-18

    To investigate the changes in hemodynamics and oxygen metabolism of different Child-grade patients during orthotopic liver transplantation (OLT) without veno-venous bypass. Forty patients with end-stage liver disease undergoing non veno-venous OLT under general anesthesia were enrolled in this research. Swan-Ganz catheter was placed in the pulmonary artery via right internal jugular vein and right radial artery was cannulated to monitor mean pulmonary artery pressure (mPAP) and artery blood pressure (ABP) continuously. Pulmonary capillary wedge pressure (PCWP) and central venous pressure (CVP) were also recorded. Cardiac output (CO) was recorded at several time points, such as, 30 min after induction (T1), when inferior vena cava and portal vein were clamped (T2), 30 min after portal vein was clamped (T3), 10 min after unclamping of portal vein (T4), 60 min after graft reperfusion (T5) and at the end of the operation (T6). Blood samples were taken from radial and pulmonary artery for blood gas analysis and hemodynamic parameters, such as, cardiac index (CI), stroke volume index (SVI), pulmonary vascular resistance index (PVRI), and system vascular resistance index (SVRI); oxygen delivery (DO2) and oxygen consumption (VO2) were also calculated at these time points. (1) The mPAP values were much higher in group C than in group A or B at all time points. CVP was significantly increased at T1 or T2 in group C as compared with those points of Child's B or C. PCWP was increased significantly after unclamping of portal vein in all three groups and was much higher at several points in Child's C than in Child's A or B. The SVRI value of T1 and the PVRI value of T3 were much lower in group C than those points in group A and the value of SVRI/PVRI was less than normal except at T3 point. And blood gas analysis elucidated that PaO2 was higher than 400 mm Hg at any points. (2) Oxygen consumption was significantly decreased during the operation due to less blood supply and was reverted to normal at the end point of the operation in all patients. Oxygen delivery was all at least 1,000 mL/min during OLT and there was no significant difference between different groups or different points. The hemodynamic state of high cardiac output with low peripheral resistance deteriorated when patients' Child-grade shifted from A to C. VO2 was less than normal value during OLT until the end point.

  2. β-glucans from Coriolus versicolor protect mice against S. typhimurium challenge by activation of macrophages.

    PubMed

    Shi, Shao-Hua; Yang, Wen-Tao; Huang, Ke-Yan; Jiang, Yan-Long; Yang, Gui-Lian; Wang, Chun-Feng; Li, Yu

    2016-05-01

    The effects of β-glucans from Coriolus versicolor (CVP), which are extracted from a well-known immune stimulator C. versicolor, have been demonstrated extensively in vitro and in vivo. However, until now, the phagocytic activity has not been elucidated. Hence, the objective of the present study was to identify the antibacterial activity of CVP or CVP-treated macrophages by an analysis of cell cytotoxicity, phagocytic activity, intracellular bacterial survival, macrophage activation, production of nitric oxide (NO) and expression of inducible nitric oxide synthase (iNOS) in CVP-treated macrophages using flow cytometry, RT-PCR, a gentamicin protection assay, a Nitric oxide assay and an iNOS enzymatic activity assay. The results indicate that CVP-treated macrophages can phagocytize and kill bacteria, probably due to the production of NO and iNOS. More importantly, CVP-treated macrophages are effective at protecting mice against the challenge of Salmonella typhimurium. The results of this study suggest that the antibacterial effects of CVP are probably caused by the activation of innate immune cells, especially macrophages, because the activated macrophage produces NO, which kills bacteria. These phenomena indicate the possibility of CVP as a potential alternative for antibiotics against resistant bacteria. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Morphological evidences in circumvallate papilla and von Ebners' gland development in mice

    PubMed Central

    Sohn, Wern-Joo; Gwon, Gi-Jeong; An, Chang-Hyeon; Moon, Cheil; Bae, Yong-Chul; Yamamoto, Hitoshi; Lee, Sanggyu

    2011-01-01

    In rodents, the circumvallate papilla (CVP), with its underlying minor salivary gland, the von Ebners' gland (VEG), is located on the dorsal surface of the posterior tongue. Detailed morphological processes to form the proper structure of CVP and VEG have not been properly elucidated. In particular, the specific localization patterns of taste buds in CVP and the branching formation of VEG have not yet been elucidated. To understand the developmental mechanisms underlying CVP and VEG formation, detailed histological observations of CVP and VEG were examined using a three-dimensional computer-aided reconstruction method with serial histological sections and pan-Cytokeratins immunostainings. In addition, to define the developmental processes in CVP and VEG formation, we examined nerve innervations and cell proliferation using microinjections of AM1-43 and immunostainings with various markers, including phosphoinositide 3-kinase, Ki-67, PGP9.5, and Ulex europaeus agglutinin 1 (UEA1). Results revealed specific morphogenesis of CVP and VEG with nerve innervations patterns, evaluated by the coincided localization patterns of AM1-43 and UEA1. Based on these morphological and immunohistochemical results, we suggest that nerve innervations and cell proliferations play important roles in the positioning of taste buds in CVP and branching morphogenesis of VEG in tongue development. PMID:22254156

  4. The Climate Variability & Predictability (CVP) Program at NOAA - Recent Program Advancements in Understanding AMOC

    NASA Astrophysics Data System (ADS)

    Lucas, S. E.

    2016-12-01

    The Climate Variability & Predictability (CVP) Program supports research aimed at providing process-level understanding of the climate system through observation, modeling, analysis, and field studies. This vital knowledge is needed to improve climate models and predictions so that scientists can better anticipate the impacts of future climate variability and change. To achieve its mission, the CVP Program supports research carried out at NOAA and other federal laboratories, NOAA Cooperative Institutes, and academic institutions. The Program also coordinates its sponsored projects with major national and international scientific bodies including the World Climate Research Programme (WCRP), the International and U.S. Climate Variability and Predictability (CLIVAR/US CLIVAR) Program, and the U.S. Global Change Research Program (USGCRP). The CVP program sits within NOAA's Climate Program Office (http://cpo.noaa.gov/CVP). This poster will present the recently funded CVP projects on improving the understanding Atlantic Meridional Overturning Circulation (AMOC), its impact on decadal predictability, and its relationship with the overall climate system.

  5. Utility gas turbine combustor viewing system: Volume 2, Engine operating envelope test: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morey, W.W.

    1988-12-01

    This report summarizes the development and field testing of a combustor viewing probe (CVP) as a flame diagnostic monitor for utility gas turbine engines. The prototype system is capable of providing a visual record of combustor flame images, recording flame spectral data, analyzing image and spectral data, and diagnosing certain engine malfunctions. The system should provide useful diagnostic information to utility plant operators, and reduced maintenance costs. The field tests demonstrated the ability of the CVP to monitor combustor flame condition and to relate changes in the engine operation with variations in the flame signature. Engine light off, run upmore » to full speed, the addition of load, and the effect of water injection for NO/sub x/ control could easily be identified on the video monitor. The viewing probe was also valuable in identifying hard startups and shutdowns, as well as transient effects that can seriously harm the engine.« less

  6. The Climate Variability & Predictability (CVP) Program at NOAA - Recent Program Advancements

    NASA Astrophysics Data System (ADS)

    Lucas, S. E.; Todd, J. F.

    2015-12-01

    The Climate Variability & Predictability (CVP) Program supports research aimed at providing process-level understanding of the climate system through observation, modeling, analysis, and field studies. This vital knowledge is needed to improve climate models and predictions so that scientists can better anticipate the impacts of future climate variability and change. To achieve its mission, the CVP Program supports research carried out at NOAA and other federal laboratories, NOAA Cooperative Institutes, and academic institutions. The Program also coordinates its sponsored projects with major national and international scientific bodies including the World Climate Research Programme (WCRP), the International and U.S. Climate Variability and Predictability (CLIVAR/US CLIVAR) Program, and the U.S. Global Change Research Program (USGCRP). The CVP program sits within NOAA's Climate Program Office (http://cpo.noaa.gov/CVP). The CVP Program currently supports multiple projects in areas that are aimed at improved representation of physical processes in global models. Some of the topics that are currently funded include: i) Improved Understanding of Intraseasonal Tropical Variability - DYNAMO field campaign and post -field projects, and the new climate model improvement teams focused on MJO processes; ii) Climate Process Teams (CPTs, co-funded with NSF) with projects focused on Cloud macrophysical parameterization and its application to aerosol indirect effects, and Internal-Wave Driven Mixing in Global Ocean Models; iii) Improved Understanding of Tropical Pacific Processes, Biases, and Climatology; iv) Understanding Arctic Sea Ice Mechanism and Predictability;v) AMOC Mechanisms and Decadal Predictability Recent results from CVP-funded projects will be summarized. Additional information can be found at http://cpo.noaa.gov/CVP.

  7. Noninvasive measurement of central venous pressure

    NASA Technical Reports Server (NTRS)

    Webster, J. G.; Mastenbrook, S. M., Jr.

    1972-01-01

    A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

  8. 75 FR 81642 - Long-Term North to South Water Transfer Program, Sacramento County, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    ...-CVP water supplies that require use of CVP or State Water Project (SWP) facilities to convey the... south of the Delta have been using water transfers to supplement local and imported water supplies... water supplies and CVP and SWP facilities. Buyers and sellers would be responsible for negotiating the...

  9. Effect of Coriolus versicolor polysaccharides on the hematological and biochemical parameters and protection against Aeromonas hydrophila in allogynogenetic crucian carp (Carassius auratus gibelio).

    PubMed

    Wu, Zhi-xin; Pang, Su-feng; Chen, Xiao-xuan; Yu, Yan-mei; Zhou, Jin-min; Chen, Xi; Pang, Li-jiao

    2013-04-01

    The effect of dietary intake of Coriolus versicolor Polysaccharides (CVP) on the hematological and biochemical indices of Allogynogenetic crucian carp (Carassius auratus gibelio) was investigated. Fish were fed CVP supplemented diets (0, 0.25, 0.5, 1.0, 2.0 or 4.0 g CVP kg(-1)) for 56 days. The RBC, WBC counts, hemoglobin content, ESR in blood and TP, ALT, AST, ALP, GLU, CHO, TG, and BUN in serum were measured on day 0, 14, 28, 42, and 56. After feeding of 56 days, fish were infected with Aeromonas hydrophila and mortalities were recorded. The results indicated that feeding crucian carp with suitable dose of CVP enhanced the RBC, WBC counts, hemoglobin and TP content, ALP activity, and decreased the ESR, ALT, AST, GLU, CHO, TG and BUN. There was no effect in fish at low dose (0.25 g kg(-1)). Unexpectedly, the higher CVP dose used here (2.0 and 4.0 g kg(-1)) has a negative effect in fish. The results of challenge experiment indicated that a moderate level of CVP in the diet (1.0 g kg(-1)) was the most effective to enhance the survival of fish after infected with A. hydrophila. In summary, the use of CVP, as dietary supplements, can improve the innate defense of crucian carp providing resistance to pathogens.

  10. The Climate Variability & Predictability (CVP) Program at NOAA - Observing and Understanding Processes Affecting the Propagation of Intraseasonal Oscillations in the Maritime Continent Region

    NASA Astrophysics Data System (ADS)

    Lucas, S. E.

    2017-12-01

    The Climate Variability & Predictability (CVP) Program supports research aimed at providing process-level understanding of the climate system through observation, modeling, analysis, and field studies. This vital knowledge is needed to improve climate models and predictions so that scientists can better anticipate the impacts of future climate variability and change. To achieve its mission, the CVP Program supports research carried out at NOAA and other federal laboratories, NOAA Cooperative Institutes, and academic institutions. The Program also coordinates its sponsored projects with major national and international scientific bodies including the World Climate Research Programme (WCRP), the International and U.S. Climate Variability and Predictability (CLIVAR/US CLIVAR) Program, and the U.S. Global Change Research Program (USGCRP). The CVP program sits within NOAA's Climate Program Office (http://cpo.noaa.gov/CVP). In 2017, the CVP Program had a call for proposals focused on observing and understanding processes affecting the propagation of intraseasonal oscillations in the Maritime Continent region. This poster will present the recently funded CVP projects, the expected scientific outcomes, the geographic areas of their work in the Maritime Continent region, and the collaborations with the Office of Naval Research, Indonesian Agency for Meteorology, Climatology and Geophysics (BMKG), Japan Agency for Marine-Earth Science and Technology (JAMSTEC) and other partners.

  11. Correlation of Blood Gas Parameters with Central Venous Pressure in Patients with Septic Shock; a Pilot Study

    PubMed Central

    Baratloo, Alireza; Rahmati, Farhad; Rouhipour, Alaleh; Motamedi, Maryam; Gheytanchi, Elmira; Amini, Fariba; Safari, Saeed

    2014-01-01

    Objective: To determine the correlation between blood gas parameters and central venous pressure (CVP) in patients suffering from septic shock. Methods: Forty adult patients with diagnosis of septic shock who were admitted to the emergency department (ED) of Shohadaye Tajrish Hospital affiliated with Shahid Beheshti University of Medical Sciences, and met inclusion and exclusion criteria were enrolled. For all patients, sampling was done for venous blood gas analysis, serum sodium and chlorine levels. At the time of sampling; blood pressure, pulse rate and CVP were recorded. Correlation between blood gas parameters and hemodynamic indices were. Results: A significant direct correlation between CVP with anion gap (AG) and inversely with base deficit (BD) and bicarbonate. CVP also showed a relative correlation with pH, whereas it was not correlated with BD/ AG ratio and serum chlorine level. There was no significant association between CVP and clinical parameters including shock index (SI) and mean arterial pressure (MAP). Conclusion: It seems that some of non invasive blood gas parameters could be served as alternative to invasive measures such as CVP in treatment planning of patients referred to an ED with septic shock. PMID:27162870

  12. Utility gas turbine combustor viewing system: Volume 1, Conceptual design and initial field testing: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morey, W.W.

    1988-12-01

    This report summarizes the development and field testing of a combustor viewing probe (CVP) as a flame diagnostic monitor for utility gas turbine engines. The prototype system is capable of providing a visual record of combustor flame images, recording flame spectral data, analyzing image and spectral data, and diagnosing certain engine malfunctions. The system should provide useful diagnostic information to utility plant operators, and reduce maintenance costs. The field tests demonstrated the ability of the CVP to monitor combustor flame condition and to relate changes in the engine operation with variations in the flame signature. Engine light off, run upmore » to full speed, the addition of load, and the effect of water injection for NO/sub x/ control could easily be identified on the video monitor. The viewing probe was also valuable in identifying hard startups and shutdowns, as well as transient effects that can seriously harm the engine. 11 refs.« less

  13. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    PubMed

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  14. Chart Venture Partners' perspective on dual-use CBRNE technologies

    NASA Astrophysics Data System (ADS)

    Van Nice, C. S.; Gardner, P. J.

    2008-04-01

    Chart Venture Partners' (CVP) approach to investing in Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) detection technologies can be best understood in the context of the unique partnership between the firm's two founding institutions. CVP was founded as a partnership between the Chart Group, a New York-based merchant banking and venture capital boutique, and InSitech Incorporated, a 501(c)(3) non-profit commercial partnership intermediary for the U.S. Army's Armament Research Development and Engineering Center (ARDEC) at Picatinny Arsenal in New Jersey. The partnership between Chart Group and Insitech has yielded a new investment model. Unlike most venture funds, CVP operates with a singular focus on early-stage defense and security technologies, with the important caveat that everything we invest in must also have dual-use application in large-scale commercial markets. CVP believes that early-stage CBRNE companies require five qualities to be viable investment candidates and successful start-up companies: Great Science, Strong IP Positions, Recognized Scientific Champions, Identified Dual-Use Market Pull, and "Real World" Technical Performance Data. When earlystage CBRNE companies decide to seek venture capital and pursue higher growth dual-use business models, we often find that certain issues arise that are not always fully contemplated at the outset, and that can create gaps between what the start-up companies are offering to investors and what those investors are seeking from their potential portfolio companies. These same issues can have significant positive or negative impact on shareholder value over time, depending on how they are managed. Specifically, startups should consider carefully their strategies related to business development, market positioning, government funding, and investment syndicate formation.

  15. A Formula for the Units to Satisfy an Operation's Desired Rate of Return in CVP Analysis--A Conceptual Approach

    ERIC Educational Resources Information Center

    Anderson, Johann A.; Leese, Wallace R.

    2016-01-01

    A common formula presented in many managerial- and cost-accounting textbooks makes possible the determination of the quantity of units which must be produced and sold to generate a desired dollar-amount of operating income. This article addresses the question "What formula can be used to determine the quantity of units needed to yield a…

  16. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    PubMed

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. A case-control study to identify risk factors for totally implantable central venous port-related bloodstream infection.

    PubMed

    Lee, Guk Jin; Hong, Sook Hee; Roh, Sang Young; Park, Sa Rah; Lee, Myung Ah; Chun, Hoo Geun; Hong, Young Seon; Kang, Jin Hyoung; Kim, Sang Il; Kim, Youn Jeong; Chun, Ho Jong; Oh, Jung Suk

    2014-07-01

    To date, the risk factors for central venous port-related bloodstream infection (CVPBSI) in solid cancer patients have not been fully elucidated. We conducted this study in order to determine the risk factors for CVP-BSI in patients with solid cancer. A total of 1,642 patients with solid cancer received an implantable central venous port for delivery of chemotherapy between October 2008 and December 2011 in a single center. CVP-BSI was diagnosed in 66 patients (4%). We selected a control group of 130 patients, who were individually matched with respect to age, sex, and catheter insertion time. CVP-BSI occurred most frequently between September and November (37.9%). The most common pathogen was gram-positive cocci (n=35, 53.0%), followed by fungus (n=14, 21.2%). Multivariate analysis identified monthly catheter-stay as a risk factor for CVP-BSI (p=0.000), however, its risk was lower in primary gastrointestinal cancer than in other cancer (p=0.002). Initial metastatic disease and long catheter-stay were statistically significant factors affecting catheter life span (p=0.005 and p=0.000). Results of multivariate analysis showed that recent transfusion was a risk factor for mortality in patients with CVP-BSI (p=0.047). In analysis of the results with respect to risk factors, prolonged catheter-stay should be avoided as much as possible. It is necessary to be cautious of CVP-BSI in metastatic solid cancer, especially non-gastrointestinal cancer. In addition, avoidance of unnecessary transfusion is essential in order to reduce the mortality of CVP-BSI. Finally, considering the fact that confounding factors may have affected the results, conduct of a well-designed prospective controlled study is warranted.

  18. Comparison of treatment outcomes between convergent procedure and catheter ablation for paroxysmal atrial fibrillation evaluated with implantable loop recorder monitoring.

    PubMed

    Jan, Matevž; Žižek, David; Geršak, Živa Miriam; Geršak, Borut

    2018-05-03

    While catheter ablation (CA) is an established treatment for symptomatic paroxysmal atrial fibrillation (AF), convergent epicardial and endocardial ablation procedure (CVP) has been primarily used to treat persistent AF. The aim of this single-center, prospective, randomized study was to compare treatment efficacy of CA and CVP in paroxysmal AF patients by monitoring AF, atrial tachycardia (AT), and atrial flutter (AFL) recurrence with Implantable Loop Recorder (ILR). Fifty patients (74% male) with history of paroxysmal AF were randomized between CA and CVP. Outcomes were determined by ILRs; every episode of AF/AT/AFL lasting 6 minutes or more was defined as a recurrence. AF burden (AFB) and required AF reinterventions (cardioversions and repeat ablations) were quantified after a 3-month blanking period. Total procedural (266 ± 44 vs. 242 ± 39 minutes) and ablation duration (52 ± 10 vs. 48 ± 12 minutes) was similar in both groups. Recurrence of AF/AT/AFL was more likely in the CA group compared to the CVP group (OR 3.78 (95% CI (1.17, 12.19), P  =  0.048)). During the follow-up period (mean 30.5 ± 6.9 months), higher AF burden and more reinterventions for recurrent AF were recorded in the CA group. There were more periprocedural complications in the CVP group (12.5%) compared to the CA group (0%). Treatment of paroxysmal AF with CVP showed less arrhythmia recurrence compared to CA. In addition, patients after CVP had fewer reinterventions and lower AF burden, but more periprocedural complications. © 2018 Wiley Periodicals, Inc.

  19. Nitroglycerine and patient position effect on central, hepatic and portal venous pressures during liver surgery.

    PubMed

    Sand, L; Lundin, S; Rizell, M; Wiklund, J; Stenqvist, O; Houltz, E

    2014-09-01

    To reduce blood loss during liver surgery, a low central venous pressure (CVP) is recommended. Nitroglycerine (NG) with its rapid onset and offset can be used to reduce CVP. In this study, the effect of NG on portal and hepatic venous pressures (PVP and HVP) in different body positions was assessed. Thirteen patients undergoing liver resection were studied. Cardiac output (CO), mean arterial pressure (MAP) and CVP were measured. PVP and HVP were measured using tip manometer catheters at baseline (BL) in horizontal position; during NG infusion, targeting a MAP of 60 mmHg, with NG infusion and the patient placed in 10 head-down position. NG infusion reduced HVP from 9.7 ± 2.4 to 7.2 ± 2.4, PVP from 12.3 ± 2.2 to 9.7 ± 3.0 and CVP from 9.8 ± 1.9 to 7.2 ± 2.1 mmHg at BL. Head-down tilt during ongoing NG resulted in increases in HVP to 8.2 ± 2.1, PVP to 10.7 ± 3 and CVP to 11 ± 1.9 mmHg. CO at BL was 6.3 ± 1.1, which was reduced by NG to 5.8 ± 1.2. Head-down tilt together with NG infusion restored CO to 6.3 ± 1.0 l/min. NG infusion leads to parallel reductions in CVP, HVP and PVP at horizontal body position. Thus, CVP can be used to guide NG dosage and fluid administration at horizontal position. NG infusion can be used to reduce HVP. Head-down tilt can be used during NG infusion to improve both blood pressure and CO without substantial increase in liver venous pressure. In head-down tilt, CVP dissociates from HVP and PVP. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Congestive kidney failure in cardiac surgery: the relationship between central venous pressure and acute kidney injury.

    PubMed

    Gambardella, Ivancarmine; Gaudino, Mario; Ronco, Claudio; Lau, Christopher; Ivascu, Natalia; Girardi, Leonard N

    2016-11-01

    Acute kidney injury (AKI) in cardiac surgery has traditionally been linked to reduced arterial perfusion. There is ongoing evidence that central venous pressure (CVP) has a pivotal role in precipitating acute renal dysfunction in cardiac medical and surgical settings. We can regard this AKI driven by systemic venous hypertension as 'kidney congestive failure'. In the cardiac surgery population as a whole, when the CVP value reaches the threshold of 14 mmHg in postoperative period, the risk of AKI increases 2-fold with an odds ratio (OR) of 1.99, 95% confidence interval (95% CI) of 1.16-3.40. In cardiac surgery subsets where venous hypertension is a hallmark feature, the incidence of AKI is higher (tricuspid disease 30%, carcinoid valve disease 22%). Even in the non-chronically congested coronary artery bypass population, CVP measured 6 h postoperatively showed significant association to renal failure: risk-adjusted OR for AKI was 5.5 (95% CI 1.93-15.5; P = 0.001) with every 5 mmHg rise in CVP for patients with CVP <9 mmHg; for CVP increments of 5 mmHg above the threshold of 9 mmHg, the risk-adjusted OR for AKI was 1.3 (95% CI 1.01-1.65; P = 0.045). This and other clinical evidence are discussed along with the underlying pathophysiological mechanisms, involving the supremacy of volume receptors in regulating the autonomic output in hypervolaemia, and the regional effect of venous congestion on the nephron. The effect of CVP on renal function was found to be modulated by ventricular function class, aetiology and acuity of venous congestion. Evidence suggests that acute increases of CVP should be actively treated to avoid a deterioration of the renal function, particularly in patients with poor ventricular fraction. Besides, the practice of treating right heart failure with fluid loading should be avoided in favour of other ways to optimize haemodynamics in this setting, because of the detrimental effects on the kidney function. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. A New Data Acquisition Portal for the Sacramento River Settlement Contractors

    NASA Astrophysics Data System (ADS)

    Narlesky, P. E., C. A.; Williams, P. E., A. M.

    2017-12-01

    In 1964, the United States Bureau of Reclamation (Reclamation) executed settlement contracts with the Sacramento River Settlement Contractors (SRSC), entities which hold water rights along the Sacramento River with area of origin protection or that are senior to Reclamation's water rights for Shasta Reservoir. Shasta is the cornerstone of the federal Central Valley Project (CVP), one of the nation's largest multi-purpose water conservation programs. In order to optimize CVP operations for multiple beneficial uses including water supply, fisheries, water quality, and waterfowl habitat, the SRSC voluntarily agreed to adaptively manage diversions throughout the year in close coordination with Reclamation. MBK Engineers assists the SRSC throughout this process by collecting, organizing, compiling, and distributing diversion data to Reclamation and others involved in operational decisions related to Shasta Reservoir and the CVP. To improve and expand participation in diversions reporting, we have developed the SRSC Web Portal, which launches a data-entry dashboard for members of the SRSC to facilitate recording and transmittal of both predicted and observed monthly and daily flow diversion data. This cloud-hosted system leverages a combination of Javascript interactive visualization libraries with a database-backed Python web framework to present streamlined data-entry forms and valuable SRSC program summary illustrations. SRSC program totals, which can now be aggregated through queries to the web-app's database backend, are used by Reclamation, SRSC, fish agencies, and others to inform operational decisions. By submitting diversion schedules and tracking actual diversions through the portal, contractors will also be directly contributing to the development of a richer and more consistently-formatted historical record for demand hydrology in the Sacramento River Watershed; this may be useful in future water supply studies. Adoption of this technology will foster an increased appreciation for the historical record of individual and combined Sacramento River diversions relative to the overall system.

  2. Concrete volute pumps: technology review and improvement

    NASA Astrophysics Data System (ADS)

    Prunières, R.; Longatte, F.; Catelan, F. X.; Philippot, J. M.

    2012-11-01

    When pumps need to deliver large water flow rates (typically more than 5 m3.s-1), concrete volute pumps (CVP) offer an interesting alternative to standard vertical wet-pit pumps. One of the major advantages of CVP is its simplicity in terms of design, manufacturability and maintainability. In addition, CVP geometrical arrangement allows to reach high performances in terms of hydraulic and mechanical behaviour. These advantages can be specifically appreciated when such pumps are used in the energy field for Power Plants which need high flow rate and reliability, and can lead to important financial savings over the Plant lifetime compared to vertical wet-pit pumps. Finally, as CVP was for a long time limited to total head rise lower than 30 mWC, it was established through CFD analysis that the addition of guide vanes between the impeller and the volute allows to achieve higher head rise without risk.

  3. Differences in Pain Subtypes Between Hispanic and Non-Hispanic White Women with Chronic Vulvar Pain

    PubMed Central

    Reese, Robyn L.; Harlow, Bernard L.

    2015-01-01

    Abstract Objectives: Compared with non-Hispanic Whites, Hispanic women have significantly higher prevalence of chronic vulvar pain (CVP), which is known to have heterogeneous subtypes. However, it is not known whether subtypes differ by ethnicity, and improved understanding of subtypes may allow for targeted clinical assessment and therapies. We examined subtypes to determine whether they differed by ethnicity. Methods: Data were from 1,551 women who reported chronic vulvar pain consistent with vulvodynia in a population-based, cross-sectional study of women from the Minneapolis/St. Paul metropolitan area, during the years 2010–2013, who returned a validated screener survey about vulvar pain. Results: Among women with CVP, Hispanics reported more primary vulvodynia (adjusted [adj.] risk ratio=1.47; p<0.01), defined as pain with first intercourse or tampon use, and tended to be more likely to describe a burning pain (adj. risk ratio=1.45; p=0.06). Hispanic women with CVP were 17% more likely than non-Hispoanic Whites with CVP to have their pain alleviated with some type of behavior/remedy (p=0.01); for example, among the subgroup of women with CVP who used yeast cream, Hispanics more often reported benefit to their pain (adj. risk ratio=1.51; p<0.01). Discussion: We examined women with CVP and found that in comparison to their non-Hispanic White counterparts, Hispanic women are more likely to report a burning sensation and more likely to have primary vulvodynia, a subtype that is associated with great burden on the lives of affected women. PMID:25603224

  4. Effects of Transcranial Direct Current Stimulation, Transcranial Pulsed Current Stimulation, and Their Combination on Brain Oscillations in Patients with Chronic Visceral Pain: A Pilot Crossover Randomized Controlled Study.

    PubMed

    Thibaut, Aurore; Russo, Cristina; Hurtado-Puerto, Aura Maria; Morales-Quezada, Jorge Leon; Deitos, Alícia; Petrozza, John Christopher; Freedman, Steven; Fregni, Felipe

    2017-01-01

    Chronic visceral pain (CVP) syndromes are persistently painful disorders with a remarkable lack of effective treatment options. This study aimed at evaluating the effects of different neuromodulation techniques in patients with CVP on cortical activity, through electreocephalography (EEG) and on pain perception, through clinical tests. A pilot crossover randomized controlled study. Out-patient. Adults with CVP (>3 months). Participants received four interventions in a randomized order: (1) transcranial pulsed current stimulation (tPCS) and active transcranial direct current stimulation (tDCS) combined, (2) tPCS alone, (3) tDCS alone, and (4) sham condition. Resting state quantitative electroencephalography (qEEG) and pain assessments were performed before and after each intervention. Results were compared with a cohort of 47 healthy controls. We enrolled six patients with CVP for a total of 21 visits completed. Compared with healthy participants, patients with CVP showed altered cortical activity characterized by increased power in theta, alpha and beta bands, and a significant reduction in the alpha/beta ratio. Regarding tES, the combination of tDCS with tPCS had no effect on power in any of the bandwidths, nor brain regions. Comparing tPCS with tDCS alone, we found that tPCS induced higher increase in power within the theta and alpha bandwidths. This study confirms that patients with CVP present abnormal EEG-indexed cortical activity compared with healthy controls. Moreover, we showed that combining two types of neurostimulation techniques had no effect, whereas the two interventions, when applied individually, have different neural signatures.

  5. Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Mack, G. W.; Nadel, E. R.

    1991-01-01

    Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.

  6. Prevention of Contrast-Induced Nephropathy by Central Venous Pressure-Guided Fluid Administration in Chronic Kidney Disease and Congestive Heart Failure Patients.

    PubMed

    Qian, Geng; Fu, Zhenhong; Guo, Jun; Cao, Feng; Chen, Yundai

    2016-01-11

    This study aimed to explore the hemodynamic index-guided hydration method for patients with congestive heart failure (CHF) and chronic kidney disease (CKD) to reduce the risk of contrast-induced nephropathy (CIN) and at the same time to avoid the acute heart failure. Patients at moderate or high risk for CIN should receive sufficient hydration before contrast application. This prospective, randomized, double-blind, comparative clinical trial enrolled 264 consecutive patients with CKD and CHF undergoing coronary procedures. These patients were randomly assigned to either central venous pressure (CVP)-guided hydration group (n = 132) or the standard hydration group (n = 132). In the CVP-guided group, the hydration infusion rate was dynamically adjusted according to CVP level every hour. CIN was defined as an absolute increase in serum creatinine (SCr) >0.5 mg/dl (44.2 μmol/l) or a relative increase >25% compared with baseline SCr. Baseline characteristics were well-matched between the 2 groups. The total mean volume of isotonic saline administered in the CVP-guided hydration group was significantly higher than the control group (1,827 ± 497 ml vs. 1,202 ± 247 ml; p < 0.001). CIN occurred less frequently in CVP-guided hydration group than the control group (15.9% vs. 29.5%; p = 0.006). The incidences of acute heart failure during the hydration did not differ between the 2 groups (3.8% vs. 3.0%; p = 0.500). CVP-guided fluid administration can safely and effectively reduce the risk of CIN in patients with CKD and CHF. (Central Venous Pressure Guided Hydration Prevention for Contrast-Induced Nephropathy; NCT02405377). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Human fetal cardiovascular profile score and neonatal outcome in intrauterine growth restriction.

    PubMed

    Mäkikallio, K; Räsänen, J; Mäkikallio, T; Vuolteenaho, O; Huhta, J C

    2008-01-01

    To determine whether low cardiovascular profile (CVP) score has prognostic value for predicting neonatal mortality and severe morbidity in human fetuses with growth restriction. Seventy-five consecutive growth-restricted fetuses with Doppler examination of cardiovascular hemodynamics within a week prior to delivery comprised the study population. Hydrops, heart size, cardiac function and venous and arterial hemodynamics were evaluated for CVP score. The primary outcome measures were neonatal mortality and cerebral palsy. During the neonatal period, six of 75 neonates died and two had cerebral palsy (Group 1, n = 8). Compared with the fetuses discharged home from hospital (Group 2, n = 67), those in Group 1 were delivered at an earlier gestational age (28 (range, 24-35) weeks vs. 35 (range, 26-40) weeks, P < 0.01) and had lower CVP scores (4 (range, 2-6) vs. 9 (range, 5-10), P < 0.0001). All CVP subscale scores were lower (P < 0.01) in Group 1 than in Group 2 fetuses. Gestational age-adjusted hazard ratios (95% CIs) for adverse neonatal outcome were highest for cardiomegaly (13.9 (1.7-114.3), P = 0.014), monophasic atrioventricular filling pattern or holosystolic tricuspid regurgitation (9.5 (2.3-38.4), P = 0.002) and atrial pulsations in the umbilical vein 7.7 (1.4-41.2), P = 0.017). Growth-restricted fetuses with adverse neonatal outcome have lower CVP scores than do fetuses with favorable neonatal outcome. The strongest predictors for adverse neonatal outcome in the CVP score were cardiomegaly, abnormal cardiac function with monophasic atrioventricular filling or holosystolic tricuspid regurgitation and increased systemic venous pressure. These assessments have independent prognostic power for adverse neonatal outcome even after adjustment for gestational age. Copyright (c) 2007 ISUOG. Published by John Wiley & Sons, Ltd.

  8. Interaction of central venous pressure, intramuscular pressure, and carotid baroreflex function

    NASA Technical Reports Server (NTRS)

    Shi, X.; Foresman, B. H.; Raven, P. B.; Blomqvist, C. G. (Principal Investigator)

    1997-01-01

    Seven healthy volunteer men participated in an experiment involving lower body positive pressure (LBPP) of 30 Torr and acute volume expansions of 5-6% (VE-I) and 9-10% (VE-II) of their total blood volume (TBV) to differentiate the effect of increased intramuscular pressure and central venous pressure (CVP) on the maximal gain (Gmax) of the carotid baroreflex. During each experimental condition, the heart rate (HR), mean arterial pressure (MAP; intraradial artery or Finapres), and CVP (at the 3rd-4th intercostal space) were monitored continuously. Gmax was derived from the logistic modeling of the HR and MAP responses to ramped changes in carotid sinus transmural pressure using a protocol of pulsatile changes in neck chamber pressure from +40 to -65 Torr. The increase in CVP during +30-Torr LBPP was 1.5 mmHg (P < 0.05) and was similar to that observed during VE-I (1.7 mmHg, P > 0.05). The Gmax of the carotid baroreflex of HR and MAP was significantly decreased during LBPP by -0.145 +/- 0.039 beats x min(-1) x mmHg(-1) (38%) and -0.071 +/- 0.013 mmHg/mmHg (25%), respectively; however, VE-I did not affect Gmax. During VE-II, CVP was significantly greater than that elicited by LBPP, and the Gmax of the carotid baroreflex of the HR and MAP responses was significantly reduced. We conclude that carotid baroreflex responsiveness was selectively inhibited by increasing intramuscular pressure, possibly resulting in an activation of the intramuscular mechanoreceptors during LBPP. Furthermore, it would appear that the inhibition of the carotid baroreflex, via cardiopulmonary baroreceptor loading (increased CVP), occurred when a threshold pressure (CVP) was achieved.

  9. Cardiovascular Differences after 4 Hours of Head-Down Bed Rest (HDBR) in Men and Women

    NASA Astrophysics Data System (ADS)

    Edgell, Heather; Grinberg, Anna; Beavers, Keith; Gagne, Nathalie; Geaves, Danielle; Hughson, Richard

    2008-06-01

    In both sexes, orthostatic responses are impaired by spaceflight or head-down bed-rest (HDBR), with a greater impact in women. We measured heart rate (HR), mean arterial blood pressure (MAP), cardiac output (Q), stroke volume (SV), central venous pressure (CVP), and total peripheral resistance (TPR) in response to lower body negative pressure (LBNP) in men (n=6) and women (n=6; day 8-11 after menstruation) before and after 4-hr HDBR or seated control (SEAT). Women exhibit lower MAP and TPR with higher SV and Q than men (normalized for body size). LBNP increased HR, decreased CVP, decreased SV, increased TPR and decreased Q. In women 4-hr SEAT results in lower CVP (P=0.015). After 4 hr HDBR men and women exhibit: 1) higher HR response (P<0.001), 2) lower resting CVP (P=0.001), 3) a tendency for higher resting Q (p=0.061). Our results indicate that inactivity and/or circadian rhythm may be important factors to consider when studying women.

  10. Diminished forearm vasomotor response to central hypervolemic loading in aerobically fit individuals

    NASA Technical Reports Server (NTRS)

    Shi, X.; Gallagher, K. M.; SMith, S. A.; Bryant, K. H.; Raven, P. B.; Blomqvist, C. G. (Principal Investigator)

    1996-01-01

    The aim of this study was to test the hypothesis that cardiopulmonary baroreflex control of forearm vascular resistance (FVR) during central hypervolemic loading was less sensitive in exercise trained high fit individuals (HF) compared to untrained average fit individuals (AF). Eight AF (age: 24 +/- 1 yr and weight: 78.9 +/- 1.7 kg) and eight HF (22 +/- 1 yr 79.5 +/- 2.4 kg) voluntarily participated in the investigation. Maximal aerobic power (determined on a treadmill), plasma volume and blood volume (Evans blue dilution method) were significantly greater in the HF than AF (60.8 +/- 0.7 vs. 41.2 +/- 1.9 ml.kg-1.min-1, 3.96 +/- 0.17 vs 3.36 +/- 0.08 1, and 6.33 +/- 0.23 vs 5.28 +/- 0.13 1). Baseline heart rate (HR), central venous pressure (CVP), mean arterial pressure (MAP, measured by an intraradial catheter or a Finapres finger cuff), forearm blood flow (FBF, plethysmography), and FVR, calculated from the ratio (MAP-CVP)/FBF, were not different between the HF and the AF. Lower body negative pressure (LBNP, -5, -10, -15, and -20 torr) and passive leg elevation (LE, 50 cm) combined with lower body positive pressure (LBPP, +5, +10, and +20 torr) were utilized to elicit central hypovolemia and hypervolemia, respectively. Range of CVP (from LBNP to LE+LBPP) was similar in the AF (from -3.9 to +1.9 mm Hg) and HF (from -4.0 to +2.2 mm Hg). However, FVR/CVP was significantly less in the HF (-1.8 +/- 0.1 unit.mm Hg-1) than AF (-34 +/- 0.1 unit.mm Hg-1). The FVR decrease in response to increase in CVP was significantly diminished in the HF (-1.46 +/- 0.45 unit.mm Hg-1) compared to the AF (-4.40 +/- 0.97 unit.mm Hg-1), and during LBNP induced unloading the FVR/CVP of the HF (-2.01 +/- 0.49 unit.mm Hg-1) was less (P < 0.08) than the AF (-3.28 +/- 0.69 unit.mm Hg-1). We concluded that the cardiopulmonary baroreceptor mediated FVR reflex response was significantly less sensitive to changes in CVP in individuals who practice exercise training.

  11. A conserved virulence plasmidic region contributes to the virulence of the multiresistant Escherichia coli meningitis strain S286 belonging to phylogenetic group C.

    PubMed

    Lemaître, Chloé; Mahjoub-Messai, Farah; Dupont, Damien; Caro, Valérie; Diancourt, Laure; Bingen, Edouard; Bidet, Philippe; Bonacorsi, Stéphane

    2013-01-01

    Recent isolation of the non-K1 Escherichia coli neonatal meningitis strain S286, belonging to phylogroup C, which is closely related to major group B1, and producing an extended-spectrum beta-lactamase, encouraged us to seek the genetic determinants responsible for its virulence. We show that S286 belongs to the sequence O type ST23O78 and harbors 4 large plasmids. The largest one, pS286colV (~120 kb), not related to resistance, contains genes characteristic of a Conserved Virulence Plasmidic (CVP) region initially identified in B2 extra-intestinal avian pathogenic E. coli (APEC) strains and in the B2 neonatal meningitis E. coli strain S88. The sequence of this CVP region has a strong homology (98%) with that of the recently sequenced plasmid pChi7122-1 of the O78 APEC strain Chi7122. A CVP plasmid-cured variant of S286 was less virulent than the wild type strain in a neonatal rat sepsis model with a significant lower level of bacteremia at 24 h (4.1 ± 1.41 versus 2.60 ± 0.16 log CFU/ml, p = 0.001) and mortality. However, the mortality in the model of adult mice was comparable between wild type and variant indicating that pS286colV is not sufficient by itself to fully explain the virulence of S286. Gene expression analysis of pS286colV in iron depleted environment was very close to that of pS88, suggesting that genes of CVP region may be expressed similarly in two very different genetic backgrounds (group C versus group B2). Screening a collection of 178 human A/B1 extraintestinal pathogenic E. coli (ExPEC) strains revealed that the CVP region is highly prevalent (23%) and MLST analysis indicated that these CVP positive strains belong to several clusters and mostly to phylogroup C. The virulence of S286 is explained in part by the presence of CVP region and this region has spread in different clusters of human A/B1 ExPEC, especially in group C.

  12. Increasing importance of precipitation variability on global livestock grazing lands

    NASA Astrophysics Data System (ADS)

    Sloat, Lindsey L.; Gerber, James S.; Samberg, Leah H.; Smith, William K.; Herrero, Mario; Ferreira, Laerte G.; Godde, Cécile M.; West, Paul C.

    2018-03-01

    Pastures and rangelands underpin global meat and milk production and are a critical resource for millions of people dependent on livestock for food security1,2. Forage growth, which is highly climate dependent3,4, is potentially vulnerable to climate change, although precisely where and to what extent remains relatively unexplored. In this study, we assess climate-based threats to global pastures, with a specific focus on changes in within- and between-year precipitation variability (precipitation concentration index (PCI) and coefficient of variation of precipitation (CVP), respectively). Relating global satellite measures of vegetation greenness (such as the Normalized Difference Vegetation Index; NDVI) to key climatic factors reveals that CVP is a significant, yet often overlooked, constraint on vegetation productivity across global pastures. Using independent stocking data, we found that areas with high CVP support lower livestock densities than less-variable regions. Globally, pastures experience about a 25% greater year-to-year precipitation variation (CVP = 0.27) than the average global land surface area (0.21). Over the past century, CVP has generally increased across pasture areas, although both positive (49% of pasture area) and negative (31% of pasture area) trends exist. We identify regions in which livestock grazing is important for local food access and economies, and discuss the potential for pasture intensification in the context of long-term regional trends in precipitation variability.

  13. Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure.

    PubMed

    Ait-Oufella, Hafid; Boelle, Pierre-Yves; Galbois, Arnaud; Baudel, Jean-Luc; Margetis, Dimitri; Alves, Mikael; Offenstadt, Georges; Maury, Eric; Guidet, Bertrand

    2012-06-28

    Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.

  14. 75 FR 34699 - Carbazole Violet Pigment 23 from India: Rescission of Countervailing Duty Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... from India: Rescission of Countervailing Duty Administrative Review AGENCY: Import Administration... review of the countervailing duty order on Carbazole Violet Pigment 23(CVP-23) from India. See... Pigments requesting an administrative review of the countervailing duty order on CVP-23 from India for the...

  15. 76 FR 24855 - Carbazole Violet Pigment 23 From India: Rescission of Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... From India: Rescission of Administrative Review AGENCY: Import Administration, International Trade... administrative review of the antidumping duty order on carbazole violet pigment 23 (CVP 23) from India for the... Federal Register the antidumping duty order on CVP 23 from India. See Notice of Amended Final...

  16. 77 FR 26578 - Draft Environmental Impact Statement/Environmental Impact Report and Notice of Public Meeting for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... fallowing) from the Exchange Contractors to other CVP contractors, to Reclamation's Refuge Water Supply... of CVP water from the Exchange Contractors to: The RWSP to meet water supply needs (Incremental Level... objectives: Develop supplemental water supplies from willing seller agencies within the Exchange Contractors...

  17. Elevated central venous pressure: A consequence of exercise training-induced hypervolemia

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Mack, Gary W.; Nadel, Ethan R.

    1990-01-01

    Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.

  18. Human Cardiovascular Adaptation to Weightlessness

    NASA Technical Reports Server (NTRS)

    Norsk, Peter

    2011-01-01

    Entering weightlessness (0 G) induces immediately a shift of blood and fluid from the lower to the upper parts of the body inducing expansion of the cardiac chambers (Bungo et al. 1986; Charles & Lathers 1991; Videbaek & Norsk 1997). For many years the effects of sudden 0 G on central venous pressure (CVP) was discussed, and it puzzled researchers that CVP compared to the 1-G supine position decreased during the initial hours of spaceflight, when at the same time left atrial diameter increased (Buckey et al. 1996). By measuring esophageal pressure as an estimate of inter-pleural pressure, it was later shown that this pressure decreases more than CVP does during 0 G induced by parabolic flights (Videbaek & Norsk 1997). Thus, transmural CVP is increased, which distends the cardiac chambers. This unique lung-heart interaction whereby 1) inter-pleural pressure decreases and 2) central blood volume is expanded is unique for 0 G. Because transmural CVP is increased, stroke volume increases according to the law of Frank-Starling leading to an increase in cardiac output, which is maintained increased during months of 0 G in space to levels of some 25% above that of the 1-G seated position (Norsk unpublished). Simultaneously, sympathetic nervous activity is at the level of the upright 1-G posture, which is difficult to explain based on the high stroke volume and decreased blood pressure and systemic vascular resistance. This paradox should be explored and the mechanisms revealed, because it might have implications for estimating the cardiovascular risk of travelling in space.

  19. What do we perceive from motion pictures? A computational account.

    PubMed

    Cheong, Loong-Fah; Xiang, Xu

    2007-06-01

    Cinema viewed from a location other than a canonical viewing point (CVP) presents distortions to the viewer in both its static and its dynamic aspects. Past works have investigated mainly the static aspect of this problem and attempted to explain why viewers still seem to perceive the scene very well. The dynamic aspect of depth perception, which is known as structure from motion, and its possible distortion, have not been well investigated. We derive the dynamic depth cues perceived by the viewer and use the so-called isodistortion framework to understand its distortion. The result is that viewers seated at a reasonably central position experience a shift in the intrinsic parameters of their visual systems. Despite this shift, the key properties of the perceived depths remain largely the same, being determined in the main by the accuracy to which extrinsic motion parameters can be recovered. For a viewer seated at a noncentral position and watching the movie screen at a slant angle, the view is related to the view at the CVP by a homography, resulting in various aberrations such as noncentral projection.

  20. The Climate Variability & Predictability (CVP) Program at NOAA - DYNAMO Recent Project Advancements

    NASA Astrophysics Data System (ADS)

    Lucas, S. E.; Todd, J. F.; Higgins, W.

    2013-12-01

    The Climate Variability & Predictability (CVP) Program supports research aimed at providing process-level understanding of the climate system through observation, modeling, analysis, and field studies. This vital knowledge is needed to improve climate models and predictions so that scientists can better anticipate the impacts of future climate variability and change. To achieve its mission, the CVP Program supports research carried out at NOAA and other federal laboratories, NOAA Cooperative Institutes, and academic institutions. The Program also coordinates its sponsored projects with major national and international scientific bodies including the World Climate Research Programme (WCRP), the International Geosphere-Biosphere Programme (IGBP), and the U.S. Global Change Research Program (USGCRP). The CVP program sits within the Earth System Science (ESS) Division at NOAA's Climate Program Office. Dynamics of the Madden-Julian Oscillation (DYNAMO): The Indian Ocean is one of Earth's most sensitive regions because the interactions between ocean and atmosphere there have a discernable effect on global climate patterns. The tropical weather that brews in that region can move eastward along the equator and reverberate around the globe, shaping weather and climate in far-off places. The vehicle for this variability is a phenomenon called the Madden-Julian Oscillation, or MJO. The MJO, which originates over the Indian Ocean roughly every 30 to 90 days, is known to influence the Asian and Australian monsoons. It can also enhance hurricane activity in the northeast Pacific and Gulf of Mexico, trigger torrential rainfall along the west coast of North America, and affect the onset of El Niño. CVP-funded scientists participated in the DYNAMO field campaign in 2011-12. Results from this international campaign are expected to improve researcher's insights into this influential phenomenon. A better understanding of the processes governing MJO is an essential step toward improving their representations in numerical models and improving MJO simulation and prediction. Recent results from CVP-funded projects will be summarized in this poster.

  1. Cardiovascular regulation in humans in response to oscillatory lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Levenhagen, D. K.; Evans, J. M.; Wang, M.; Knapp, C. F.

    1994-01-01

    The frequency response characteristics of human cardiovascular regulation during hypotensive stress have not been determined. We therefore exposed 10 male volunteers to seven frequencies (0.004-0.1 Hz) of oscillatory lower body negative pressure (OLBNP; 0-50 mmHg). Fourier spectra of arterial pressure (AP), central venous pressure (CVP), stroke volume (SV), cardiac output (CO), heart rate (HR), and total peripheral resistance (TPR) were determined and first harmonic mean, amplitude, and phase angles with respect to OLBNP are presented. AP was relatively well regulated as demonstrated by small oscillations in half amplitude (3.5 mmHg) that were independent of OLBNP frequency and similar to unstressed control spectra. Due to the biomechanics of the system, the magnitudes of oscillations in calf circumference (CC) and CVP decreased with increasing frequency; therefore, we normalized responses by these indexes of the fluid volume shifted. The ratios of oscillations in AP to oscillations in CC increased by an order of magnitude, whereas oscillations in CVP to oscillations in CC and oscillations in AP to oscillations in CVP both tripled between 0.004 and 0.1 Hz. Therefore, even though the amount of fluid shifted by OLBNP decreased with increasing frequency, the magnitude of both CVP and AP oscillations per volume of fluid shifted increased (peaking at 0.08 Hz). The phase relationships between variables, particularly the increasing lags in SV and TPR, but not CVP, indicated that efferent responses with lags of 5-6 s could account for the observed responses. We conclude that, at frequencies below 0.02 Hz, the neural system of humans functioned optimally in regulating AP; OLBNP-induced decreases in SV (by as much as 50%) were counteracted by appropriate oscillations in HR and TPR responses. As OLBNP frequency increased, SV, TPR, and HR oscillations increasingly lagged the input and became less optimally timed for AP regulation.

  2. Phase I Study of Inotuzumab Ozogamicin Combined with R-CVP for Relapsed/Refractory CD22+ B-cell Non-Hodgkin Lymphoma.

    PubMed

    Ogura, Michinori; Tobinai, Kensei; Hatake, Kiyohiko; Davies, Andrew; Crump, Michael; Ananthakrishnan, Revathi; Ishibashi, Taro; Paccagnella, M Luisa; Boni, Joseph; Vandendries, Erik; MacDonald, David

    2016-10-01

    To evaluate the safety, preliminary efficacy, and pharmacokinetics of inotuzumab ozogamicin, an anti-CD22 antibody conjugated to calicheamicin, in combination with the immunochemotherapeutic regimen, rituximab, cyclophosphamide, vincristine, and prednisone (R-CVP), in patients with relapsed/refractory CD22+ B-cell non-Hodgkin lymphoma (NHL). In part 1 (n = 16), patients received inotuzumab ozogamicin plus R-CVP on a 21-day cycle with escalating doses of cyclophosphamide first then inotuzumab ozogamicin. Part 2 (n = 10) confirmed the safety and tolerability of the maximum tolerated dose (MTD), which required a dose-limiting toxicity rate of <33% in cycle 1 and <33% of patients discontinuing before cycle 3 due to treatment-related adverse events (AEs). Part 3 (n = 22) evaluated the preliminary efficacy of inotuzumab ozogamicin plus R-CVP. The MTD was determined to be standard-dose R-CVP plus inotuzumab ozogamicin 0.8 mg/m 2 The most common treatment-related grade ≥3 AEs in the MTD cohort (n = 38) were hematologic: neutropenia (74%), thrombocytopenia (50%), lymphopenia (42%), and leukopenia (47%). Among the 48 patients treated in the study, 13 discontinued due to AEs, most commonly thrombocytopenia (n = 10). Overall, 13 patients died, including one death due to treatment-related pneumonia secondary to neutropenia. Among patients receiving the MTD (n = 38), the overall response rate (ORR) was 84% (n = 32), including 24% (n = 9) with complete response; the ORR was 100% for patients with indolent lymphoma (n = 27) and 57% for those with aggressive histology lymphoma (n = 21). Inotuzumab ozogamicin at 0.8 mg/m 2 plus full dose R-CVP was associated with manageable toxicities and demonstrated a high rate of response in patients with relapsed/refractory CD22+ B-cell NHL. The study is registered at ClinicalTrials.gov (NCT01055496). Clin Cancer Res; 22(19); 4807-16. ©2016 AACR. ©2016 American Association for Cancer Research.

  3. Importance Attributed to Cardiovascular and Pulmonary Competencies by Public Sector Physical Therapists in Kuwait: A Population-based Exploratory Study.

    PubMed

    Al-Sayegh, Nowall; Al-Shuwai, Nadia; Al-Obaidi, Saud M; Dean, Elizabeth

    2016-09-01

    Indications for cardiovascular and pulmonary (CVP) physical therapy competencies are changing with the epidemic of non-communicable diseases in Kuwait, particularly lifestyle-related conditions. The degree to which the country's physical therapists (PTs) perceive the importance of CVP competencies (assessment/evaluation and clinical and laboratory investigation interpretation) in professional practice is relevant. Our study objectives were to (1) explore the importance attributed to specific CVP competencies by PTs to professional practice in Kuwait and (2) establish whether these are related to practitioner traits, for example, age, sex, practice setting and specialty. The study design was exploratory with a stratified random sample. Questionnaires (n = 221) were distributed to PTs practicing in the facilities of the Ministry of Health, the primary employer of PTs in Kuwait. Questions included participants' demographics and perceived importance of specific CVP competencies (Likert rating scale 1-not important to 5-highly important). Response rate was 87% (n = 193). Participant mean age was 36(±9) years, 63% were women and 48% were Kuwaiti. Ratings of moderately important or higher were 84% for cardiac assessment/intervention skills, 78.8% for cardiac clinical/laboratory investigations interpretation, 77.2% for pulmonary assessment/intervention skills and 73.6% for pulmonary clinical/laboratory investigations interpretation. PTs in the musculoskeletal area attributed less importance to the competencies than those in other specialties. Participants perceived CVP competencies as generally relevant to practice. However, greater importance was attributed to these competencies in relation to management of CVP conditions (e.g. those that address lifestyle-related conditions) rather than across practice areas. Research is needed to elucidate whether this finding reflects the profession's commitment to holistic care, the prevalence of lifestyle-related risk factors and conditions irrespective of a patient's primary complaint presenting to the PT, best evidence-based, non-pharmacologic practice to address these or some combination. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  4. 76 FR 12755 - Notice of Intent To Prepare an Environmental Impact Statement (EIS) and Hold Public Scoping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... terms and conditions regarding the constraints on availability of water supply for the CVP M&I water service contracts. Allocation of CVP water supplies for any given water year is based upon forecasted... requirements, and management of Section 3406(b)(2) resources and refuge water supplies in accordance with CVPIA...

  5. The Phase of Illness Paradigm: A Checklist Centric Model to Improve Patient Care in the Burn Intensive Care Unit

    DTIC Science & Technology

    2016-04-01

    oxygenation and ventilation Goal Adequate oxygenation and/or ventilation Goal Skin grafting Objective Surgical operation (implicit goal = achieve...Abdominal Pressures, [TTE/IVC measurement] Assure effective Ventilation & Sedation (Standard ICU) EtCO2, A-Line, ±CVP 4E Compatible Decrease...commands) Participatory (expresses self)  minimize oxygen demand  maximize perfusion  protect grafts  patient ventilator

  6. 75 FR 29718 - Carbazole Violet Pigment 23 From India and the People's Republic of China: Continuation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ...\\ triphenodioxazine, 8,18-dichloro-5, 15-diethyl-5, 15-dihydro-, and molecular formula of C 34 H 22 Cl 2 N 4 O 2 . The... CONTACT: Bryan Hansen or Minoo Hatten, AD/CVD Operations, Office 5, Import Administration, International... antidumping duty orders on CVP-23 from India and the PRC \\1\\ pursuant to section 751(c) of the Tariff Act of...

  7. The Effects of Cultural Video Resources on Teaching and Learning Korean Language

    ERIC Educational Resources Information Center

    Roh, Jaemin

    2011-01-01

    This dissertation sought to evaluate the potential of a customized, video-based instructional method, the Cultural Video Project (CVP), which was designed to meet the needs of both heritage and non-heritage students learning Korean as a second language in a university setting. The goal of this study was to design and create the CVP, document the…

  8. The Synergistic Beneficial Effects of Ginkgo Flavonoid and Coriolus versicolor Polysaccharide for Memory Improvements in a Mouse Model of Dementia.

    PubMed

    Fang, Xianying; Jiang, Yan; Ji, Hui; Zhao, Linguo; Xiao, Wei; Wang, Zhenzhong; Ding, Gang

    2015-01-01

    This study reports the combination of Ginkgo flavonoid (GF) and Coriolus versicolor polysaccharide (CVP) in the prevention and treatment of a mouse model of Alzheimer's disease (AD). GF is a traditional health product, and CVP is the main active ingredient of the medicinal fungus Coriolus versicolor. The Morris water maze test, the Y maze, and the step-through test showed that the combinational use of CVP and GF synergistically improved memory in a mouse model of AD. Based on H&E staining analysis, the combination of CVP and GF decreased the severity of the pathological findings in the brain. Given that the expression of IL-1β, IL-6, and TNF-α was downregulated, the inflammation response in AD mice was considered to be inhibited. The downregulation of GFAP further demonstrated that inflammation was reduced in the brain of AD mice following treatment. Moreover, the expression levels of superoxide dismutase (SOD) and catalase (CAT) were elevated in the brains of treated mice, indicating that oxidation levels were reduced upon the combination treatment. Our results provide new insights into the efficient utilization of traditional medicine for preventing dementia.

  9. The Synergistic Beneficial Effects of Ginkgo Flavonoid and Coriolus versicolor Polysaccharide for Memory Improvements in a Mouse Model of Dementia

    PubMed Central

    Fang, Xianying; Jiang, Yan; Ji, Hui; Xiao, Wei; Wang, Zhenzhong; Ding, Gang

    2015-01-01

    This study reports the combination of Ginkgo flavonoid (GF) and Coriolus versicolor polysaccharide (CVP) in the prevention and treatment of a mouse model of Alzheimer's disease (AD). GF is a traditional health product, and CVP is the main active ingredient of the medicinal fungus Coriolus versicolor. The Morris water maze test, the Y maze, and the step-through test showed that the combinational use of CVP and GF synergistically improved memory in a mouse model of AD. Based on H&E staining analysis, the combination of CVP and GF decreased the severity of the pathological findings in the brain. Given that the expression of IL-1β, IL-6, and TNF-α was downregulated, the inflammation response in AD mice was considered to be inhibited. The downregulation of GFAP further demonstrated that inflammation was reduced in the brain of AD mice following treatment. Moreover, the expression levels of superoxide dismutase (SOD) and catalase (CAT) were elevated in the brains of treated mice, indicating that oxidation levels were reduced upon the combination treatment. Our results provide new insights into the efficient utilization of traditional medicine for preventing dementia. PMID:25821476

  10. Behavioral sensitization to amphetamine induced by a single i.p. dose of oxotremorine in the rat.

    PubMed

    Gralewicz, Sławomir

    2002-01-01

    Earlier experiments have revealed that rats treated with a single dose of chlorphenvinphos (CVP), an irreversible acetylcholinesterase inhibitor, are hyposensitive to amphetamine (AMPH) given three weeks after CVP. Exposure to CVP results in an excess of acetylcholine with subsequent overactivation of the nicotinic as well as muscarinic cholinergic receptors. The purpose of the present experiment was to find out whether a selective activation of muscarinic receptors could induce behavioral hyposensitivity to AMPH. To attain this purpose, male rats were pretreated once with 0.00, 0.135, 0.27 or 0.55 mg/kg of oxotremorine, a muscarinic agonist, and challenged 15 days later with 1.0 mg/kg dose of AMPH. The pre- and postinjection open-field behavior of the rats was tested with the use of a computerized set of activity meters. The testing revealed that in oxotremorine pretreated animals the behavioral response to AMPH, i.e. increase in the ambulatory activity, was not diminished but, to the contrary, it was augmented. This effect was dose-dependent, being most pronounced in rats given the 0.55 mg/kg of oxotremorine. The possible cause of the difference between the effect of CVP and oxotremorine is discussed.

  11. Fabp4-CreER lineage tracing reveals two distinctive coronary vascular populations.

    PubMed

    He, Lingjuan; Tian, Xueying; Zhang, Hui; Wythe, Joshua D; Zhou, Bin

    2014-11-01

    Over the last two decades, genetic lineage tracing has allowed for the elucidation of the cellular origins and fates during both embryogenesis and in pathological settings in adults. Recent lineage tracing studies using Apln-CreER tool indicated that a large number of post-natal coronary vessels do not form from pre-existing vessels. Instead, they form de novo after birth, which represents a coronary vascular population (CVP) distinct from the pre-existing one. Herein, we present new coronary vasculature lineage tracing results using a novel tool, Fabp4-CreER. Our results confirm the distinct existence of two unique CVPs. The 1(st) CVP, which is labelled by Fabp4-CreER, arises through angiogenic sprouting of pre-existing vessels established during early embryogenesis. The 2(nd) CVP is not labelled by Fabp4, suggesting that these vessels form de novo, rather than through expansion of the 1(st) CVP. These results support the de novo formation of vessels in the post-natal heart, which has implications for studies in cardiovascular disease and heart regeneration. © 2014 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  12. An Online Cross-Sectional Comparison of Women With Symptoms of Persistent Genital Arousal, Painful Persistent Genital Arousal, and Chronic Vulvar Pain.

    PubMed

    Jackowich, Robyn A; Pink, Leah; Gordon, Allan; Poirier, Évéline; Pukall, Caroline F

    2018-04-01

    Persistent genital arousal disorder (PGAD) is an understudied condition characterized by unwanted physiologic genital arousal in the absence of subjective sexual arousal. Markos and Dinsmore (Int J STD AIDS 2013;24:852-858) theorized that PGAD shares a number of similarities with vulvodynia (unexplained chronic vulvar pain [CVP]), including symptom characteristics and comorbidities. To compare medical histories, symptom characteristics, pain characteristics, and daily functioning among women with persistent genital pain (PGA) (n = 42), painful PGA (n = 37), and CVP (n = 42) symptoms. An online cross-sectional survey was conducted from October 2015 through April 2016. Self-report measures of symptoms, diagnosed medical conditions, pain characteristics (McGill Pain Questionnaire), catastrophizing (Pain Catastrophizing Scale), and daily functioning (Functional Status Questionnaire) were collected. All 3 groups reported similar medical diagnoses and high frequencies of other chronic pelvic pain conditions. Women in all 3 groups reported comparable ages at symptom onset and timing of symptom expression (ie, constant vs intermittent). Women in the 2 PGA groups reported significantly greater feelings of helplessness than women in the CVP group. Women in the painful PGA and CVP groups endorsed significantly more sensory terms to describe their symptoms compared with women in the PGA group, whereas women in the painful PGA group reported significantly more affective terms to describe their symptoms compared with women in the CVP group. Women in the 2 PGA groups reported that their symptoms interfered significantly with most areas of daily functioning. Given the similarities between PGA and CVP symptoms, women with PGA may benefit from similar assessment, treatment, and research approaches. Limitations of the present study include its sole use of self-report measures; the presence of PGA or CVP symptoms was not confirmed by clinical assessment. However, the anonymous design of the online survey could have resulted in a larger and more diverse sample. The results of this study provide some initial support for the conceptualization of persistent genital arousal as a subtype of genital paresthesias/discomfort. These results also further highlight the negative impact that PGA symptoms have on many domains of daily living and the need for further research on this distressing condition. Jackowich RA, Pink L, Gordon A, et al. An Online Cross-Sectional Comparison of Women With Symptoms of Persistent Genital Arousal, Painful Persistent Genital Arousal, and Chronic Vulvar Pain. J Sex Med 2018;15:558-567. Copyright © 2018 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  13. Pack-and-Go Delivery Service: A Multi-Component Cost-Volume-Profit (CVP) Learning Resource

    ERIC Educational Resources Information Center

    Stout, David E.

    2014-01-01

    This educational case, in two parts (A and B), requires students to assume the role of a business consultant and to use Excel to develop a profit-planning or a cost-volume-profit (CVP) model for a package-delivery company opportunity currently being evaluated by a client. The name of the proposed business is Pack-and-Go, which would provide an…

  14. Lower initial central venous pressure in septic patients from long-term care facilities than in those from the community.

    PubMed

    Lin, Chun-Yu; Chen, Tun-Chieh; Lu, Po-Liang; Chen, Hui-Juan; Bojang, Kebba S; Chen, Yen-Hsu

    2014-10-01

    The cornerstone of emergency management of severe sepsis and septic shock is early (within 6 hours) goal-directed therapy, including maintenance of central venous pressure (CVP) at 8-12 mmHg. It is unclear whether there is a difference in initial (baseline) CVP between septic patients who are referred from the community and those who come from long-term care facilities (LTCFs) in Taiwan. We designed this study to investigate the difference in hemodynamic parameters between these two groups. Every patient with severe sepsis or septic shock who had a central venous catheter inserted via the internal jugular or subclavian vein at Kaohsiung Medical University Hospital between April 2007 and October 2007 was enrolled. CVP was measured immediately at the emergency department. Patient demographics, including residence, were retrospectively recorded and analyzed. There were 166 evaluable patients; 125 (75.3%) came from the community and 41 (24.7%) from LTCFs. There were no significant differences in age, sex, initial body temperature, heart rate, blood pressure, or leukocyte count between the two groups. However, patients who were referred from LTCFs had a significantly lower initial CVP than those from the community (5.0 ± 4.5 mmHg vs. 7.0 ± 4.8 mmHg, p = 0.023). The difference was more significant between mechanically ventilated patients from LTCFs and those from the community (5.0 ± 3.0 mmHg vs. 8.1 ± 5.6 mmHg, p = 0.006). Severely septic patients referred from LTCFs may require more aggressive fluid resuscitation within the first 6 hours of the diagnostic criteria met at the emergency department to achieve the CVP target of early goal-directed therapy. Copyright © 2013. Published by Elsevier B.V.

  15. The Sterol Methyltransferases SMT1, SMT2, and SMT3 Influence Arabidopsis Development through Nonbrassinosteroid Products1[W][OA

    PubMed Central

    Carland, Francine; Fujioka, Shozo; Nelson, Timothy

    2010-01-01

    Plant sterols are structural components of cell membranes that provide rigidity, permeability, and regional identity to membranes. Sterols are also the precursors to the brassinosteroid signaling molecules. Evidence is accumulating that specific sterols have roles in pattern formation during development. COTYLEDON VASCULAR PATTERNING1 (CVP1) encodes C-24 STEROL METHYLTRANSFERASE2 (SMT2), one of three SMTs in Arabidopsis (Arabidopsis thaliana). SMT2 and SMT3, which also encodes a C-24 SMT, catalyze the reaction that distinguishes the synthesis of structural sterols from signaling brassinosteroid derivatives and are highly regulated. The deficiency of SMT2 in the cvp1 mutant results in moderate developmental defects, including aberrant cotyledon vein patterning, serrated floral organs, and reduced stature, but plants are viable, suggesting that SMT3 activity can substitute for the loss of SMT2. To test the distinct developmental roles of SMT2 and SMT3, we identified a transcript null smt3 mutant. Although smt3 single mutants appear wild type, cvp1 smt3 double mutants show enhanced defects relative to cvp1 mutants, such as discontinuous cotyledon vein pattern, and produce novel phenotypes, including defective root growth, loss of apical dominance, sterility, and homeotic floral transformations. These phenotypes are correlated with major alterations in the profiles of specific sterols but without significant alterations to brassinosteroid profiles. The alterations to sterol profiles in cvp1 mutants affect auxin response, demonstrated by weak auxin insensitivity, enhanced axr1 auxin resistance, ectopically expressed DR5:β-glucuronidase in developing embryos, and defective response to auxin-inhibited PIN2-green fluorescent protein endocytosis. We discuss the developmental roles of sterols implied by these results. PMID:20421456

  16. Effect of exercise training on cardiopulmonary baroreflex control of forearm vascular resistance in humans

    NASA Technical Reports Server (NTRS)

    Mack, G. W.; Convertino, V. A.; Nadel, E. R.

    1993-01-01

    We studied the stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR) in four groups of male volunteer subjects: i) unfit, ii) physically fit, iii) before and after 10 wk of endurance training (chronic blood volume expansion), and iv) before and after acute blood volume expansion. We assessed the relationship between reflex stimulus, i.e., changes in central venous pressure and response, i.e., FVR, during unloading of cardiopulmonary mechanoreceptors with lower body negative pressure (LBNP, 0 to -20 mm Hg). The slope of the linear relationship between FVR and CVP, the index of the responsiveness of this baroreflex, was significantly diminished (> 50%) in the fit subjects compared with the unfit. The slope of the FVR-CVP relationship was inversely correlated with the subject's total blood volume, suggesting that blood volume expansion was related to the attenuated CP baroreflex. In the exercise training study, maximal oxygen consumption and blood volume increased following 10 wk of endurance training (N = 14) but were unchanged in the time control group (N = 7). The slope of the FVR-CVP relationship was significantly reduced (32%) following 10 wk of training but was unchanged in the time control group. The reduction in slope of the FVR-CVP relationship was inversely related to the increase in blood volume associated with exercise training. Acute blood volume expansion 8 ml.kg-1 body weight with 5% human serum albumin solution) significantly reduced the slope of the FVR-CVP relationship. These data support the hypothesis that the attenuated forearm vascular reflex in physically fit individuals is related to a training-induced hypervolemia.(ABSTRACT TRUNCATED AT 250 WORDS).

  17. West Europe Report

    DTIC Science & Technology

    1987-04-02

    the ground. The cesium also follows the needles themselves when they drop off the trees. Pines change their needles over a 3 - year ...according to the influences that predominate within it. But who makes up the CVP today? Where does the CVP recruit its membership? How can a party...led the government for nearly 4 years now. He is ready for a new similar career if he is asked. "It is not

  18. Vortex dynamics in the near-wake of tabs with various geometries using 2D and 3D PIV

    NASA Astrophysics Data System (ADS)

    Pagan-Vazquez, Axy; Khovalyg, Dolaana; Marsh, Charles; Hamed, Ali M.; Chamorro, Leonardo P.

    2016-11-01

    The vortex dynamics and turbulence statistics in the near-wake of rectangular, trapezoidal, triangular, and ellipsoidal tabs were studied in a refractive-index-matching channel at Re = 2000 and 13000, based on the tab height. The tabs share the same bulk dimensions including a 17 mm height, a 28 mm base width, and a 24.5o angle. 3D PIV was used to study the mean flow and dominant large-scale vortices, while high-spatial resolution planar PIV was used to quantify high-order statistics. The results show the coexistence of counter-rotating vortex pair (CVP) and hairpin structures. These vortices exhibit distinctive topology and strength across Re and tab geometry. The CVP is a steady structure that grows in strength over a significantly longer distance at the low Re due to the lower turbulence levels and the delayed shedding of the hairpin vortices. These features at the low Re are associated with the presence of K-H instability that develops over three tab heights. The interaction between the hairpins and CVP is measured in 3D for the first time and shows complex coexistence. Although the CVP suffers deformation and splitting at times, it maintains its presence and leads to significant spanwise and wall-normal flows.

  19. Transition metal doping of GaSe implemented with low temperature liquid phase growth

    NASA Astrophysics Data System (ADS)

    Lei, Nuo; Sato, Youhei; Tanabe, Tadao; Maeda, Kensaku; Oyama, Yutaka

    2017-02-01

    Our group works on improving the conversion efficiencies of terahertz (THz) wave generation using GaSe crystals. The operating principle is based on difference frequency generation (DFG) which has the advantages such as high output power, a single tunable frequency, and room temperature operation. In this study, GaSe crystals were grown by the temperature difference method under controlled vapor pressure (TDM-CVP). It is a liquid phase growth method with temperature 300 °C lower than that of the Bridgman method. Using this method, the point defects concentration is decreased and the polytype can be controlled. The transition metal Ti was used to dope the GaSe in order to suppress free carrier absorption in the low frequency THz region. As a result, a deep acceptor level of 38 meV was confirmed as being formed in GaSe with 1.4 at% Ti doping. Compared with undoped GaSe, a decrease in carrier concentration ( 1014 cm-3) at room temperature was also confirmed. THz wave transmittance measurements reveal the tendency for the absorption coefficient to increase as the amount of dopant is increased. It is expected that there is an optimum amount of dopant.

  20. Retrieval of detached fragment of central venous pressure catheter (CVP) lodged in the right ventricle and pulmonary artery: a case report.

    PubMed

    Sakijan, A S; Zambahari, R; Annuar, Z; Yahya, O; Ali, J

    1990-12-01

    A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detached catheter fragment by percutaneous means obviates the need for thoracotomy.

  1. [Effect of Coriolus versicolor polysaccharide B on membrane glycosaminoglycans and cellular glutathione changes in RAW264.7 macrophages exposed to angiotensin II].

    PubMed

    Lou, Ning; Ma, Gang; Wang, Dao-feng; Zhu, Zhi-wei; Su, Quan-guan; Fang, Yi

    2007-12-01

    To investigate the effect of Coriolus versicolor polysaccharide B (CVP-B) on increased membrane glycosaminoglycans (GAG) expression and intracellular glutathione (GSH) of RAW264.7 macrophages exposed to angiotensin II (Ang II). The plasma membrane of RAW264.7 macrophages exposed to Ang II treatment was isolated by ultracentrifugation, and the membrane GAG expression was analyzed using 1, 9-dimethylmethylene blue (DMMB) spectrophotometric assay for sulfated GAG. The intracellular reduced GSH was determined using fluorophotometry. The GAG content in the macrophage membranes increased by up to 54% following cell exposure to 1.0 micromol/L Ang II, whereas in presence of 1.0 micromol;/L Ang II, CVP-B at 1, 10, and 50 microg/ml decreased the GAG content by 13%, 43% (P<0.01), and 52% (P<0.01), respectively. The macrophage GSH activity decreased by 69% following incubation with 1.0 micromol;/L Ang II for 24 h, and CVP-B treatment at 1, 10, and 50 microg/ml in presence of 1.0 micromol;/L Ang II resulted in significant increment of GSH activity by 31%(P<0.05), 104% (P<0.01), and 168% (P<0.01), respectively. These data provide the first evidence that CVP-B inhibits elevated GAG expression in RAW264.7 macrophage membrane induced by Ang II.

  2. Posture with elevated and extended thorax. The influence of the position on some haemodynamic and ventilatory parameters under general anaesthesia.

    PubMed

    Videbaek, F

    1980-12-01

    The effects of a change in posture from flat supine to supine with elevated and extended thorax have been investigated in 12 healthy patients under general anaesthesia prior to elective surgery on the stomach. The following parameters were measured: pulse rate, mean arterial blood pressure (MABP), central venous pressure (CVP), ventilation pressure, oesophageal pressure, and arterial oxygen and carbon dioxide tensions. Changes were measured as deviations from initial values before the change of position at 4 and 15 min after the change. One patient (8%) had a 31% fall in MABP and a 87% fall in CVP, requiring treatment outside the standard procedure, but acceptable values were obtained by simple means. Eleven patients showed only minor changes: a mean initial rise in pulse rate of 10% and a fall in CVP of 25%, after which the pulse rate returned to the initial level and the CVP remained stable. MABP was unchanged, as were ventilation pressure, oesophageal pressure and gas tensions. On the basis of reports in the literature and findings in this study, it is concluded that otherwise healthy patients tolerate the posture well, the slight risk of haemodynamic complications being outweighed by the surgical advantages. This posture should be used with caution in patients who may be haemodynamically unable to compensate.

  3. Prevention of cardiovascular disease in rheumatoid arthritis.

    PubMed

    Hollan, I; Dessein, P H; Ronda, N; Wasko, M C; Svenungsson, E; Agewall, S; Cohen-Tervaert, J W; Maki-Petaja, K; Grundtvig, M; Karpouzas, G A; Meroni, P L

    2015-10-01

    The increased risk of cardiovascular disease (CVD) in rheumatoid arthritis (RA) has been recognized for many years. However, although the characteristics of CVD and its burden resemble those in diabetes, the focus on cardiovascular (CV) prevention in RA has lagged behind, both in the clinical and research settings. Similar to diabetes, the clinical picture of CVD in RA may be atypical, even asymptomatic. Therefore, a proactive screening for subclinical CVD in RA is warranted. Because of the lack of clinical trials, the ideal CVD prevention (CVP) in RA has not yet been defined. In this article, we focus on challenges and controversies in the CVP in RA (such as thresholds for statin therapy), and propose recommendations based on the current evidence. Due to the significant contribution of non-traditional, RA-related CV risk factors, the CV risk calculators developed for the general population underestimate the true risk in RA. Thus, there is an enormous need to develop adequate CV risk stratification tools and to identify the optimal CVP strategies in RA. While awaiting results from randomized controlled trials in RA, clinicians are largely dependent on the use of common sense, and extrapolation of data from studies on other patient populations. The CVP in RA should be based on an individualized evaluation of a broad spectrum of risk factors, and include: 1) reduction of inflammation, preferably with drugs decreasing CV risk, 2) management of factors associated with increased CV risk (e.g., smoking, hypertension, hyperglycemia, dyslipidemia, kidney disease, depression, periodontitis, hypothyroidism, vitamin D deficiency and sleep apnea), and promotion of healthy life style (smoking cessation, healthy diet, adjusted physical activity, stress management, weight control), 3) aspirin and influenza and pneumococcus vaccines according to current guidelines, and 4) limiting use of drugs that increase CV risk. Rheumatologists should take responsibility for the education of health care providers and RA patients regarding CVP in RA. It is immensely important to incorporate CV outcomes in testing of anti-rheumatic drugs. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Cost Effectiveness of the 13-Valent Pneumococcal Conjugate Vaccination Program in Chronic Obstructive Pulmonary Disease Patients Aged 50+ Years in Spain.

    PubMed

    Rodríguez González-Moro, Jose Miguel; Menéndez, Rosario; Campins, Magda; Lwoff, Nadia; Oyagüez, Itziar; Echave, María; Rejas, Javier; Antoñanzas, Fernando

    2016-01-01

    Patients with chronic obstructive pulmonary disease (COPD) are at elevated risk of pneumococcal infection. A 13-valent pneumococcal conjugate vaccine (PCV13) was approved for protection against invasive disease and pneumonia caused by Streptococcus pneumoniae in adults. This study estimated the incremental cost-effectiveness ratio (ICER) of vaccinating COPD patients ≥50 years old with PCV13 compared with current vaccination policy (CVP) with 23-valent pneumococcal polysaccharide vaccine. A Markov model accounting for the risks and costs for all-cause non-bacteremic pneumonia (NBP) and invasive pneumococcal disease (IPD) was developed. All parameters, such as disease incidence and costs (€; 2015 values), were based on published data. The perspective of the analysis was that of the Spanish National Healthcare System, and the horizon of evaluation was lifetime in the base case. Vaccine effectiveness considered waning effect over time. Outcomes and costs were both discounted by 3% annually. Over a lifetime horizon and for a 629,747 COPD total population, PCV13 would prevent 2224 cases of inpatient NBP, 3134 cases of outpatient NBP, and 210 IPD extra cases in comparison with CVP. Additionally, 398 related deaths would be averted. The ICER was €1518 per quality-adjusted life-year (QALY) gained for PCV13 versus CVP. PCV13 was found to be cost effective versus CVP from a 5-year modelling horizon (1302 inpatient NBP and 1835 outpatient NBP cases together with 182 deaths would be prevented [ICER €25,573/QALY]). Univariate and probabilistic sensitivity analyses confirmed the robustness of the model. At the commonly accepted willingness-to-pay threshold of €30,000/QALY gained, PCV13 vaccination in COPD patients aged ≥50 years was a cost-effective strategy compared with CVP from 5 years to lifetime horizon in Spain.

  5. The Binomial Model in Fluctuation Analysis of Quantal Neurotransmitter Release

    PubMed Central

    Quastel, D. M. J.

    1997-01-01

    The mathematics of the binomial model for quantal neurotransmitter release is considered in general terms, to explore what information might be extractable from statistical aspects of data. For an array of N statistically independent release sites, each with a release probability p, the compound binomial always pertains, with = N

    , p′ ≡ 1 - var(m)/ =

    (1 + cvp2) and n′ ≡ /p′ = N/(1 + cvp2), where m is the output/stimulus and cvp2 is var(p)/

    2. Unless n′ is invariant with ambient conditions or stimulation paradigms, the simple binomial (cvp = 0) is untenable and n′ is neither N nor the number of “active” sites or sites with a quantum available. At each site p = popA, where po is the output probability if a site is “eligible” or “filled” despite previous quantal discharge, and pA (eligibility probability) depends at least on the replenishment rate, po, and interstimulus time. Assuming stochastic replenishment, a simple algorithm allows calculation of the full statistical composition of outputs for any hypothetical combinations of po's and refill rates, for any stimulation paradigm and spontaneous release. A rise in n′ (reduced cvp) tends to occur whenever po varies widely between sites, with a raised stimulation frequency or factors tending to increase po's. Unlike and var(m) at equilibrium, output changes early in trains of stimuli, and covariances, potentially provide information about whether changes in reflect change in or in . Formulae are derived for variance and third moments of postsynaptic responses, which depend on the quantal mix in the signals. A new, easily computed function, the area product, gives noise-unbiased variance of a series of synaptic signals and its peristimulus time distribution, which is modified by the unit channel composition of quantal responses and if the signals reflect mixed responses from synapses with different quantal time course. PMID:9017200

  6. Diminished Baroreflex Control of Forearm Vascular Resistance Following Training

    NASA Technical Reports Server (NTRS)

    Mack, G. W.; Thompson, C. A.; Doerr, D. F.; Nadel, E. R.; Convertino, V. A.

    1991-01-01

    The stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR units in mm Hg x min x I00 ml/ml) were studied in 14 volunteers before and after 10 wk of endurance training. We assessed the relationship betaleen reflex stimulus (changes in central venous pressure, CVP) and response (FVR) during unloading of cardiopulmonary baroreceptors with lower body negative pressure (LBNP, 0 to - 2O mm Hg). Changes in CVP during LBNP were estimated from pressure changes in a large peripheral vein in the dependent arm of the subject in the right lateral decubitus position. Maximal oxygen uptake (VO(sub 2max)) and total blood volume increased with endurance training from 37.8 +/- 1.4 ml/min x kg and 63.6 +/- 2.1 ml/kg to 45.3 +/- 1.4 ml/ min x kg and 69.3 +/- 2.8 ml/kg respectively (P less than 0.05). Reflex forearm vasoconstriction occurred in response to a reduction in estimated CVP, and the absolute change in FVR per unit of CVP was reduced from -5.96 +/- 0.79 to -4.06 +/- 0.52 units x mm/ Hg (P less than 0.05) following exercise training but was unchanged from -6.10 to 0.57 to -6.22 +/- 0.94 units x mm/ Hg for the time control group (N = 7). Resting values for FVR were similar before and after exercise training; however, resting estimated CVP was elevated from 9.5 +/- 0.5 mm x Hg before training to 11.3 +/- 0.6 mm x Hg after training. The reduction in sensitivity of the cardiopulmonary baroreflex control of FVR was linearly related to the increase in blood volume (r = 0.65, P less than 0.05). suggesting that diminished cardiopulmonary baroreflex control of FVR in physically fit individuals is related, in part, to a training-induced blood volume expansion.

  7. Stereo-vision-based cooperative-vehicle positioning using OCC and neural networks

    NASA Astrophysics Data System (ADS)

    Ifthekhar, Md. Shareef; Saha, Nirzhar; Jang, Yeong Min

    2015-10-01

    Vehicle positioning has been subjected to extensive research regarding driving safety measures and assistance as well as autonomous navigation. The most common positioning technique used in automotive positioning is the global positioning system (GPS). However, GPS is not reliably accurate because of signal blockage caused by high-rise buildings. In addition, GPS is error prone when a vehicle is inside a tunnel. Moreover, GPS and other radio-frequency-based approaches cannot provide orientation information or the position of neighboring vehicles. In this study, we propose a cooperative-vehicle positioning (CVP) technique by using the newly developed optical camera communications (OCC). The OCC technique utilizes image sensors and cameras to receive and decode light-modulated information from light-emitting diodes (LEDs). A vehicle equipped with an OCC transceiver can receive positioning and other information such as speed, lane change, driver's condition, etc., through optical wireless links of neighboring vehicles. Thus, the target vehicle position that is too far away to establish an OCC link can be determined by a computer-vision-based technique combined with the cooperation of neighboring vehicles. In addition, we have devised a back-propagation (BP) neural-network learning method for positioning and range estimation for CVP. The proposed neural-network-based technique can estimate target vehicle position from only two image points of target vehicles using stereo vision. For this, we use rear LEDs on target vehicles as image points. We show from simulation results that our neural-network-based method achieves better accuracy than that of the computer-vision method.

  8. Determination of Cd2+ in aqueous solution using polyindole-Ce(IV) vanadophosphate conductive nanocomposite ion-selective membrane electrode

    NASA Astrophysics Data System (ADS)

    Khan, Asif Ali; Quasim Khan, Mohd; Hussain, Rizwan

    2017-09-01

    In the present study an organic-inorganic nanocomposite ion exchanger Polyindole-Ce(IV) vanadophosphate (PIn-CVP) was synthesized via sol-gel process showing excellent ion exchange capacity (IEC‒1.90 meqg-1). The material was characterized by SEM, TEM, XRD, FTIR, and TGA. A heterogeneous ion exchange membrane of PIn-CVP (IEC‒0.90 meqg-1) was also prepared by solution casting method. PIn-CVP shows high electrical conductivity (5.5  ×  10-2 S cm-1) and it is stable up to 120 °C under ambient conditions. Cd2+ selective membrane electrode was fabricated and its linear working range (3.98  ×  10-7 M to 1.0  ×  10-1 M), response time (25 s), Nerstian slope 25.00 mV dec-1 and working pH range (4-7) were calculated. It was employed as an indicator electrode in the potentiometric titration of Cd2+.

  9. Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study.

    PubMed

    Lanspa, Michael J; Brown, Samuel M; Hirshberg, Eliotte L; Jones, Jason P; Grissom, Colin K

    2012-12-01

    Volume expansion is a common therapeutic intervention in septic shock, although patient response to the intervention is difficult to predict. Central venous pressure (CVP) and shock index have been used independently to guide volume expansion, although their use is questionable. We hypothesize that a combination of these measurements will be useful. In a prospective, observational study, patients with early septic shock received 10-mL/kg volume expansion at their treating physician's discretion after brief initial resuscitation in the emergency department. Central venous pressure and shock index were measured before volume expansion interventions. Cardiac index was measured immediately before and after the volume expansion using transthoracic echocardiography. Hemodynamic response was defined as an increase in a cardiac index of 15% or greater. Thirty-four volume expansions were observed in 25 patients. A CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less individually had a good negative predictive value (83% and 88%, respectively). Of 34 volume expansions, the combination of both a high CVP and a low shock index was extremely unlikely to elicit hemodynamic response (negative predictive value, 93%; P = .02). Volume expansion in patients with early septic shock with a CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less is unlikely to lead to an increase in cardiac index. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. The effects of collaborative video production on the attitudes and science knowledge of sixth graders

    NASA Astrophysics Data System (ADS)

    Gaston, Joseph Pickett

    This quantitative study examined the effects of collaborative video production (CVP) on the attitudes and conceptual understanding of sixth-grade science students at a public middle school in the Southeastern United States. This study followed the nonequivalent control group design, as described by Campbell and Stanley (1963). The study involved four classes of sixth-grade students. The two control classes were taught the science concept by the cooperating teacher through direct instruction, and the two experimental classes learned the science concept through the CVP project. Pre- and posttests were administered to all students, as well as two pre- and post-surveys measuring student attitudes towards science and technology. Analysis of covariance (ANCOVA) with the pretest scores as the covariate (Xc) was conducted with the posttest and post-survey data to determine if a significant difference existed in scores between the two groups. In each case, no significant difference was found. The results of this study suggest that CVP was as effective at conveying conceptual understanding to sixth-grade science students as direct instruction. Although not significant, the study also showed that mean scores of students' attitudes towards science and technology increased from pre-surveys to post-surveys for those who participated in the CVP activity. These findings suggest that the treatment contributed to an increase in participants' attitudes and towards technology and the academic subject. No such increase in mean post-survey scores existed for students receiving direct instruction.

  11. Cardiovascular function following reduced aerobic activity

    NASA Technical Reports Server (NTRS)

    Raven, P. B.; Welch-O'Connor, R. M.; Shi, X.; Blomqvist, C. G. (Principal Investigator)

    1998-01-01

    PURPOSE: The aim of this study was to test the hypothesis that a sustained reduction of physical activity (deconditioning) would alter the cardiovascular regulatory function. METHODS: Nineteen young, healthy volunteers participated in physical deconditioning for a period of 8 wk. Before (pre) and following (post) physical deconditioning, the responses of heart rate (HR), mean arterial pressure (MAP, measured by Finapres), central venous pressure (CVP), stroke volume (SV, Doppler), and forearm blood flow (FBF, plethysmography) were determined during lower body negative pressure (LBNP). The carotid baroreflex (CBR) function was assessed using a train of pulsatile neck pressure (NP) and suction, and the aortic baroreflex control of HR was assessed during steady-state phenylephrine (PE) infusion superimposed by LBNP and NP to counteract the PE increased CVP and carotid sinus pressure, respectively. RESULTS: Active physical deconditioning significantly decreased maximal oxygen uptake (-7%) and LBNP tolerance (-13%) without a change in baseline hemodynamics. Plasma volume (-3% at P = 0.135), determined by Evans Blue dilution, and blood volume (-4% at P = 0.107) were not significantly altered. During LBNP -20 to -50 torr, there was a significantly greater drop of SV per unit decrease in CVP in the post- (14.7 +/- 1.6%/mm Hg) than predeconditioning (11.2 +/- 0.7%/mm Hg) test accompanied by a greater tachycardia. Deconditioning increased the aortic baroreflex sensitivity (pre vs post: -0.61 +/- 0.12 vs -0.84 +/- 0.14 bpm.mm-1 Hg, P = 0.009) and the slope of forearm vascular resistance (calculated from [MAP-CVP]/FBF) to CVP (-2.75 +/- 0.26 vs -4.94 +/- 0.97 PRU/mm Hg, P = 0.086). However, neither the CBR-HR (-0.28 +/- 0.03 VS -0.39 +/- 0.10 bpm.mm-1 Hg) nor the CBR-MAP (-0.37 +/- 0.16 vs -0.25 +/- 0.07 mm Hg/mm Hg) gains were statistically different between pre- and postdeconditioning. CONCLUSIONS: We concluded that the functional modification of the cardiac pressure-volume relationship resulted in the reduced LBNP tolerance, despite the accentuated aortic and cardiopulmonary baroreflex function following deconditioning.

  12. Influence of body position on hemodynamics in patients with ischemic heart disease undergoing cardiac surgery.

    PubMed

    Mekis, Dusan; Kamenik, Mirt

    2010-05-01

    The cardiovascular response to decreased or increased preload in high-risk patients with ischemic heart disease enables us to understand the physiologic response to hemorrhage and its treatment. Although numerous studies have failed to show its effectiveness, the head-down position is still widely used to treat patients with hypotension and shock. The aim of our study was to evaluate the influence of body position on hemodynamics in high-risk patients undergoing coronary artery bypass graft surgery. In 16 patients with ischemic hearth disease and poor left ventricular function undergoing coronary artery bypass graft surgery, we measured cardiac output with thermodilution, arterial pressure, central venous pressure (CVP), pulmonary artery wedge pressure (PAWP) and heart rate in three different body positions: the horizontal position, 20 degrees head-up position, 20 degrees head-down position and back in the horizontal position. The measurements were made before and after cardiac surgery. Before skin incision the change from horizontal to 20 degrees head-up position led to a nonsignificant decrease in cardiac output and a significant decrease in mean arterial pressure, CVP and PAWP. The change from 20 degrees head-up to 20 degrees head-down position led to a significant increase in cardiac output, mean arterial pressure, CVP and PAWP. After skin closure the change from horizontal to 20 degrees head-up position led to a nonsignificant decrease in cardiac output and mean arterial pressure and a significant decrease CVP and PAWP. The change from 20 degrees head-up to 20 degrees head-down position led to a nonsignificant increase in cardiac output and a significant increase in mean arterial pressure, CVP and PAWP. There were no significant changes in heart rate during the changes in position before or after surgery. The results of our study showed a hemodynamic response similar to hemorrhage after placing the patients in a 20 degrees head-up position and improving hemodynamics in the head-down position in mechanically ventilated patients undergoing coronary artery bypass graft surgery.

  13. Cardiopulmonary baroreceptor control of muscle sympathetic nerve activity in heat-stressed humans

    NASA Technical Reports Server (NTRS)

    Crandall, C. G.; Etzel, R. A.; Farr, D. B.

    1999-01-01

    Whole body heating decreases central venous pressure (CVP) while increasing muscle sympathetic nerve activity (MSNA). In normothermia, similar decreases in CVP elevate MSNA, presumably via cardiopulmonary baroreceptor unloading. The purpose of this project was to identify whether increases in MSNA during whole body heating could be attributed to cardiopulmonary baroreceptor unloading coincident with the thermal challenge. Seven subjects were exposed to whole body heating while sublingual temperature, skin blood flow, heart rate, arterial blood pressure, and MSNA were monitored. During the heat stress, 15 ml/kg warmed saline was infused intravenously over 7-10 min to increase CVP and load the cardiopulmonary baroreceptors. We reported previously that this amount of saline was sufficient to return CVP to pre-heat stress levels. Whole body heating increased MSNA from 25 +/- 3 to 39 +/- 3 bursts/min (P < 0. 05). Central blood volume expansion via rapid saline infusion did not significantly decrease MSNA (44 +/- 4 bursts/min, P > 0.05 relative to heat stress period) and did not alter mean arterial blood pressure (MAP) or pulse pressure. To identify whether arterial baroreceptor loading decreases MSNA during heat stress, in a separate protocol MAP was elevated via steady-state infusion of phenylephrine during whole body heating. Increasing MAP from 82 +/- 3 to 93 +/- 4 mmHg (P < 0.05) caused MSNA to decrease from 36 +/- 3 to 15 +/- 4 bursts/min (P < 0.05). These data suggest that cardiopulmonary baroreceptor unloading during passive heating is not the primary mechanism resulting in elevations in MSNA. Moreover, arterial baroreceptors remain capable of modulating MSNA during heat stress.

  14. Water transfer and major environmental provisions of the Central Valley Project Improvement Act: A preliminary economic evaluation

    NASA Astrophysics Data System (ADS)

    Loomis, John B.

    1994-06-01

    Increasing block water pricing, water transfer, and wildlife refuge water supply provisions of the Central Valley Project (CVP) Improvement Act are analyzed in terms of likely farmer response and economic efficiency of these provisions. Based on a simplified partial equilibrium analysis, we estimate small, but significant water conservation savings due to pricing reform, the potential for substantial water transfers to non-CVP customers in severe drought years when the water price exceeds 110 per acre foot (1 acre foot equals 1.234 × 103 m3) and positive net benefits for implementation of the wildlife refuge water supply provisions. The high threshold water price is partly a result of requiring farmers to pay full cost on transferred water plus a surcharge of 25 per acre foot if the water is transferred to a non-CVP user. The act also sets an important precedent for water pricing reform, water transfer provisions, and environmental surcharges on water users that may find their way to other Bureau of Reclamation projects.

  15. Fast engineering optimization: A novel highly effective control parameterization approach for industrial dynamic processes.

    PubMed

    Liu, Ping; Li, Guodong; Liu, Xinggao

    2015-09-01

    Control vector parameterization (CVP) is an important approach of the engineering optimization for the industrial dynamic processes. However, its major defect, the low optimization efficiency caused by calculating the relevant differential equations in the generated nonlinear programming (NLP) problem repeatedly, limits its wide application in the engineering optimization for the industrial dynamic processes. A novel highly effective control parameterization approach, fast-CVP, is first proposed to improve the optimization efficiency for industrial dynamic processes, where the costate gradient formulae is employed and a fast approximate scheme is presented to solve the differential equations in dynamic process simulation. Three well-known engineering optimization benchmark problems of the industrial dynamic processes are demonstrated as illustration. The research results show that the proposed fast approach achieves a fine performance that at least 90% of the computation time can be saved in contrast to the traditional CVP method, which reveals the effectiveness of the proposed fast engineering optimization approach for the industrial dynamic processes. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Spatial variation of vessel grouping in the xylem of Betula platyphylla Roth.

    PubMed

    Zhao, Xiping

    2016-01-01

    Vessel grouping in angiosperms may improve hydraulic integration and increase the spread of cavitations through redundancy pathways. Although disputed, it is increasingly attracting research interest as a potentially significant hydraulic trait. However, the variation of vessel grouping in a tree is poorly understood. I measured the number of solitary and grouped vessels in the xylem of Betula platyphylla Roth. from the pith to the bark along the water flow path. The vessel grouping parameters included the mean number of vessels per vessel group (VG), percentage of solitary vessels (SVP), percentage of radial multiple vessels (MVP), and percentage of cluster vessels (CVP). The effects of cambial age (CA) and flow path-length (PL) on the vessel grouping were analyzed using a linear mixed model.VG and CVP increased nonlinearly, SVP decreased nonlinearly with PL. In trunks and branches, VG and CVP decreased nonlinearly, and SVP increased nonlinearly with CA. In roots, the parameters had no change with CA. MVP was almost constant with PL or CA. The results suggest that vessel grouping has a nonrandom variation pattern, which is affected deeply by cambial age and water flow path.

  17. Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

    NASA Technical Reports Server (NTRS)

    Ebert, D.; Macias, B.; Garcia, K.; Stenger, M.; Hargens, A.; Johnston, S.

    2016-01-01

    Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

  18. Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

    NASA Technical Reports Server (NTRS)

    Ebert, Douglas; Macias, Brandon; Sargsyan, Ashot; Garcia, Kathleen; Stenger, Michael; Hargens, Alan; Johnston, Smith; Kemp, David; Danielson, Richard

    2016-01-01

    Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

  19. Protective effects of recombinant human brain natriuretic peptide in perioperative period during open heart surgery.

    PubMed

    Xu, Yunbin; Li, Yong; Bao, Weiguo; Qiu, Shi

    2018-03-01

    The aim of the present study was to evaluate the protective effects and safety aspects of recombinant human brain natriuretic peptide (rhBNP) on cardiac functions of patients undergoing open-heart surgery during perioperative period. In total, 150 patients undergoing open heart surgery in the Second Hospital of Shandong Universty from August 2015 to July 2016 were randomly divided into control group and observation group each with 75 cases. Patients in control group were treated by routine rehabilitation while patients in the observation group were treated by both the routine rehabilitation and rhBNP. All the observations were made before operation, after operation and 7 days after operation. The changes of N-terminal pro-brain natriuretic peptide (NT-proBNP) of patients, the left ventricular ejection fraction (LVEF), cardiac function [Cardiac output (CO), pulmonary capillary wedge pressure (PAWP) and central venous pressure (CVP)] of patients were measured. Further, respirator support time, ICU stay time, incidence of complications and vital signs (BP, HR, SaO2) of patients in the two groups were also compared. NT-proBNP levels of all patients improved after operation but it decreased in both groups after 7 days of operation. The decrease of NT-proBNP levels in observation group was significantly higher than that of control group. Whereas, LVEF, CO, PAWP and CVP of patients in both the groups increased after operation but effects were significantly higher in the observation group after 7 days of medication. Respirator support time and ICU stay time of patients in observation group were significantly shorter than those in control group, and the incidence of postoperative complications of patients in the observation group were significantly lower than the control group. Moreover, BP, HR and SaO2 of patients in observation group were significantly elevated in comparison to control group (P<0.05). Recombinant human brain natriuretic peptide (rhBNP) could significantly improve the cardiac functions of patients after open heart surgery, and is safe as well as reliable.

  20. Partial protection from organophosphate-induced cholinesterase inhibition by metyrapone treatment.

    PubMed

    Swiercz, Radosław; Lutz, Piotr; Gralewicz, Sławomir; Grzelińska, Zofia; Piasecka-Zelga, Joanna; Wąsowicz, Wojciech

    2013-08-01

    Organophosphates are cholinesterase (ChE) inhibitors with worldwide use as insecticides. Stress response, evidenced by a dramatic and relatively long-lasting (several hours) rise in the plasma glucocorticoid concentration is an integral element of the organophosphate (OP) poisoning symptomatology. In rodents, corticosterone (CORT) is the main glucocorticoid. There are several reports suggesting a relationship between the stressor-induced rise in CORT concentration (the CORT response) and the activity of the cerebral and peripheral ChE. Thus, it seems reasonable to presume that, in OP intoxication, the rise in plasma CORT concentration may somehow affect the magnitude of the OP-induced ChE inhibition. Metyrapone (MET) [2-methyl-1,2-di(pyridin-3-yl)propan-1-one] blocks CORT synthesis by inhibiting steroid 11β-hydroxylase, thereby preventing the CORT response. Chlorfenvinphos (CVP) [2-chloro-1-(2,4-dichlorophenyl) ethenyl diethyl phosphate] is an organophosphate insecticide still in use in some countries. The purpose of the present work was to compare the CVP-induced effects - the rise of the plasma CORT concentration and the reduction in ChE activity - in MET-treated and MET-untreated rats. Chlorfenvinphos was administered once at 0.0, 0.5, 1.0 and 3.0 mg/kg i.p. Metyrapone, at 100 mg/kg i.p., was administered five times, at 24-h intervals. The first MET dose was given two hours before CVP. The following was observed in the MET-treated rats: i) no rise in plasma CORT concentration after the CVP administration, ii) a reduced inhibition and a faster restitution of blood and brain ChE activities. The results suggest that MET treatment may confer significant protection against at least some effects of OP poisoning. The likely mechanism of the protective MET action has been discussed.

  1. Human cerebral venous outflow pathway depends on posture and central venous pressure

    PubMed Central

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  2. Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakamoto, Noriaki, E-mail: nosakamoto@hotmail.co.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Takeuchi, Yoshito, E-mail: yostakeu@ncc.go.jp

    2010-10-15

    The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurredmore » in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.« less

  3. Reduction in central venous pressure enhances erythropoietin synthesis: role of volume-regulating hormones.

    PubMed

    Montero, D; Rauber, S; Goetze, J P; Lundby, C

    2016-10-01

    Erythropoiesis is a tightly controlled biological event, but its regulation under non-hypoxic conditions, however, remains unresolved. We examined whether acute changes in central venous blood pressure (CVP) elicited by whole-body tilting affect erythropoietin (EPO) concentration according to volume-regulating hormones. Plasma EPO, angiotensin II (ANGII), aldosterone, pro-atrial natriuretic peptide (proANP) and copeptin concentrations were measured at supine rest and up to 3 h during 30° head-up (HUT) and head-down tilt (HDT) in ten healthy male volunteers. Plasma albumin concentration was used to correct for changes in plasma volume and CVP was estimated through the internal jugular vein (IJV) aspect ratio with ultrasonography. From supine rest, the IJV aspect ratio was decreased and increased throughout HUT and HDT respectively. Plasma EPO concentration increased during HUT (13%; P = 0.001, P for linear component = 0.017), independent of changes in albumin concentration. Moreover, ANGII and copeptin concentrations increased during HUT, while proANP decreased. The increase in EPO concentration during HUT disappeared when adjusted for changes in copeptin. During HDT, EPO, ANGII and copeptin concentrations remained unaffected while proANP increased. In regression analyses, EPO was positively associated with copeptin (β = 0.55; 95% CI = 0.18, 0.93; P = 0.004) irrespective of changes in other hormones and albumin concentration. Reduction in CVP prompts an increase in plasma EPO concentration independent of hemoconcentration and hence suggests CVP per se as an acute regulator of EPO synthesis. This effect may be explained by changes in volume-regulating hormones. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  4. Effects of different ratios and storage periods of liquid brewer's yeast mixed with cassava pulp on chemical composition, fermentation quality and in vitro ruminal fermentation.

    PubMed

    Kamphayae, Sukanya; Kumagai, Hajime; Angthong, Wanna; Narmseelee, Ramphrai; Bureenok, Smerjai

    2017-04-01

    This study aims to evaluate the chemical composition, fermentation quality and in vitro ruminal fermentation of various ratios and storage periods of liquid brewer's yeast (LBY) mixed with cassava pulp (CVP). Four mixtures of fresh LBY and CVP were made (LBY0, LBY10, LBY20, and LBY30 for LBY:CVP at 0:100, 10:90, 20:80, and 30:70, respectively) on a fresh matter basis, in 500 g in plastic bags and stored at 30 to 32°C. After storage, the bags were opened weekly from weeks 0 to 4. Fermentation quality and in vitro gas production (IVGP) were determined, as well as the dry matter (DM), organic matter (OM), crude protein (CP), ether extract (EE), neutral detergent fiber, acid detergent fiber and acid detergent lignin contents. The contents of CP and EE increased, whereas all other components decreased, in proportion to LBY inclusion (p<0.01). The DM and OM contents gradually decreased in weeks 3 and 4 (p<0.05), while EE contents were lowest in week 0. The pH, ammonia nitrogen per total nitrogen (NH 3 -N/TN) and V-score in each mixture and storage period demonstrated superior fermentation quality (pH≤4.2, NH 3 -N/TN≤12.5%, and V-score>90%). The pH increased and NH 3 -N/TN decreased, with proportionate increases of LBY, whereas the pH decreased and NH 3 -N/TN increased, as the storage periods were extended (p<0.01). Although IVGP decreased in proportion to the amount of LBY inclusion (p<0.01), in vitro organic matter digestibility (IVOMD) was unaffected by the mixture ratios. The highest IVGP and IVOMD were observed in week 0 (p<0.01). The inclusion of LBY (as high as 30%) into CVP improves the chemical composition of the mixture, thereby increasing the CP content, while decreasing IVGP, without decreasing fermentation quality and IVOMD. In addition, a preservation period of up to four weeks can guarantee superior fermentation quality in all types of mixtures. Therefore, we recommend limiting the use of CVP as a feed ingredient, given its low nutritional value and improving feed quality with the inclusion of LBY.

  5. Right ventricular response to pulsatile load is associated with early right heart failure and mortality after left ventricular assist device.

    PubMed

    Grandin, E Wilson; Zamani, Payman; Mazurek, Jeremy A; Troutman, Gregory S; Birati, Edo Y; Vorovich, Esther; Chirinos, Julio A; Tedford, Ryan J; Margulies, Kenneth B; Atluri, Pavan; Rame, J Eduardo

    2017-01-01

    Right ventricular (RV) adaptation to afterload is crucial for patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. We hypothesized that stratifying patients by RV pulsatile load, using pulmonary arterial compliance (PAC), and RV response to load, using the ratio of central venous to pulmonary capillary wedge pressure (CVP:PCWP), would identify patients at high risk for early right heart failure (RHF) and 6-month mortality after cf-LVAD. During the period from January 2008 to June 2014, we identified 151 patients at our center with complete hemodynamics prior to cf-LVAD. Pulsatile load was estimated using PAC indexed to body surface area (BSA), according to the formula: indexed PAC (PACi) = [SV / (PA systolic - PA diastolic )] / BSA, where SV is stroke volume and PA is pulmonary artery. Patients were divided into 4 hemodynamic groups by PACi and CVP:PCWP. RHF was defined as the need for unplanned RVAD, inotropic support ≥14 days or death due to RHF within 14 days. Risk factors for RHF and 6-month mortality were examined using logistic regression and Cox proportional hazards modeling. Sixty-one patients (40.4%) developed RHF and 34 patients (22.5%) died within 6 months. Patients with RHF had lower PACi (0.92 vs 1.17 ml/mm Hg/m 2 , p = 0.008) and higher CVP:PCWP (0.48 vs 0.37, p = 0.001). Higher PACi was associated with reduced risk of RHF (adjusted odds ratio [adj-OR] 0.61, 95% confidence interval [CI] 0.39 to 0.94, p = 0.025) and low PACi with increased risk of 6-month mortality (adjusted hazard ratio [adj-HR] 3.18, 95% CI 1.40 to 7.25, p = 0.006). Compared to patients with low load (high PACi) and adequate right heart response to load (low CVP:PCWP), patients with low PACi and high CVP:PCWP had an increased risk of RHF (OR 4.74, 95% CI 1.23 to 18.24, p = 0.02) and 6-month mortality (HR 8.68, 95% CI 2.79 to 26.99, p < 0.001). A hemodynamic profile combining RV pulsatile load and response to load identifies patients at high risk for RHF and 6-month mortality after cf-LVAD. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  6. Water and gas geochemistry of the Calatrava Volcanic Province (CVP) hydrothermal system (Ciudad Real, central Spain)

    NASA Astrophysics Data System (ADS)

    Vaselli, Orlando; Nisi, Barbara; Tassi, Franco; Giannini, Luciano; Grandia, Fidel; Darrah, Tom; Capecchiacci, Francesco; del Villar, Pèrez

    2013-04-01

    An extensive geochemical and isotopic investigation was carried out in the water and gas discharges of the Late Miocene-Quaternary Calatrava Volcanic Province (CVP) (Ciudad Real, Spain) with the aim reconstruct the fluid circulation in the area. CVP consists of a series of scattered (monogenetic) vents from where alkaline lava flows and pyroclastic deposits formed in two different periods. The first stage (8.7-6.4 Ma) mainly included ultra-potassic mafic extrusives, whilst the second stage (4.7-1.75 Ma) prevalently originated alkaline and ultra-alkaline volcanics. Both stages were followed by a volcanic activity that extended up to 1.3 and 0.7 Ma, respectively. This area can likely be regarded as one of the most important emitting zones of CO2 in the whole Peninsular Spain along with that of Selva-Emporda in northeastern Spain (Cataluña) and it can be assumed as one of the best examples of natural analogues of CO2 leakages in Spain. This latter aspect is further evidenced by the relatively common water-gas blast events that characterize the CCVF. In the last few years the presence of a CO2-pressurized reservoir at a relatively shallow level as indeed caused several small-sized explosion particularly during the drilling of domestic wells. The fluid discharging sites are apparently aligned along well-defined directions: NW-SE and NNW-SSE and subordinately, ENE-WSW, indicating a clear relationship between the thermal discharges and the volcanic centers that also distribute along these lineaments. The CVP waters are mostly hypothermal (up to 33 °C) and are generally Mg(Ca)-HCO3 in composition and occasionally show relatively high concentrations of Fe and Mn, with pH and electrical conductivity down to 5.5 and up to 6.5 mS/cm, respectively. The oxygen and hydrogen isotopes suggest a meteoric origin for these waters. The mantle source of these volcanic products is apparently preserved in the many CO2-rich (up to 990,000 mmol/mol) gas discharges that characterize CVP, whose carbon and helium isotopic signature is characterized by values between -6.8 and -3.2 ‰ (V-PDB) and up to 2.7 R/Ra, respectively. Nitrogen and argon are atmospheric in origin and their contents are up to 11,850 and 313 mmol/mol, respectively, while H2S and CH4, despite occurring in the great majority of the CVP samples, have concentrations that rarely achieve 71 and 81 mmol/mol, respectively. It is worthwhile to mention that the N2/Ar ratios are occasionally characterized by values higher that those of the atmospheric and air saturated water and the respective 40Ar/36Ar values are higher than the atmospheric ratio (295.5), suggesting a deep source for these inert gases.

  7. The caudo-ventral pallium is a novel pallial domain expressing Gdf10 and generating Ebf3-positive neurons of the medial amygdala.

    PubMed

    Ruiz-Reig, Nuria; Andres, Belen; Lamonerie, Thomas; Theil, Thomas; Fairén, Alfonso; Studer, Michèle

    2018-06-04

    In rodents, the medial nucleus of the amygdala receives direct inputs from the accessory olfactory bulbs and is mainly implicated in pheromone-mediated reproductive and defensive behaviors. The principal neurons of the medial amygdala are GABAergic neurons generated principally in the caudo-ventral medial ganglionic eminence and preoptic area. Beside GABAergic neurons, the medial amygdala also contains glutamatergic Otp-expressing neurons cells generated in the lateral hypothalamic neuroepithelium and a non-well characterized Pax6-positive population. In the present work, we describe a novel glutamatergic Ebf3-expressing neuronal subpopulation distributed within the periphery of the postero-ventral medial amygdala. These neurons are generated in a pallial domain characterized by high expression of Gdf10. This territory is topologically the most caudal tier of the ventral pallium and accordingly, we named it Caudo-Ventral Pallium (CVP). In the absence of Pax6, the CVP is disrupted and Ebf3-expressing neurons fail to be generated. Overall, this work proposes a novel model of the neuronal composition of the medial amygdala and unravels for the first time a new novel pallial subpopulation originating from the CVP and expressing the transcription factor Ebf3.

  8. Performance analysis of vortex based mixers for confined flows

    NASA Astrophysics Data System (ADS)

    Buschhagen, Timo

    The hybrid rocket is still sparsely employed within major space or defense projects due to their relatively poor combustion efficiency and low fuel grain regression rate. Although hybrid rockets can claim advantages in safety, environmental and performance aspects against established solid and liquid propellant systems, the boundary layer combustion process and the diffusion based mixing within a hybrid rocket grain port leaves the core flow unmixed and limits the system performance. One principle used to enhance the mixing of gaseous flows is to induce streamwise vorticity. The counter-rotating vortex pair (CVP) mixer utilizes this principle and introduces two vortices into a confined flow, generating a stirring motion in order to transport near wall media towards the core and vice versa. Recent studies investigated the velocity field introduced by this type of swirler. The current work is evaluating the mixing performance of the CVP concept, by using an experimental setup to simulate an axial primary pipe flow with a radially entering secondary flow. Hereby the primary flow is altered by the CVP swirler unit. The resulting setup therefore emulates a hybrid rocket motor with a cylindrical single port grain. In order to evaluate the mixing performance the secondary flow concentration at the pipe assembly exit is measured, utilizing a pressure-sensitive paint based procedure.

  9. Brachial cuff measurements of blood pressure during passive leg raising for fluid responsiveness prediction.

    PubMed

    Lakhal, K; Ehrmann, S; Benzekri-Lefèvre, D; Runge, I; Legras, A; Dequin, P-F; Mercier, E; Wolff, M; Régnier, B; Boulain, T

    2012-05-01

    The passive leg raising maneuver (PLR) for fluid responsiveness testing relies on cardiac output (CO) measurements or invasive measurements of arterial pressure (AP) whereas the initial hemodynamic management during shock is often based solely on brachial cuff measurements. We assessed PLR-induced changes in noninvasive oscillometric readings to predict fluid responsiveness. Multicentre interventional study. In ICU sedated patients with circulatory failure, AP (invasive and noninvasive readings) and CO measurements were performed before, during PLR (trunk supine, not modified) and after 500-mL volume expansion. Areas under the ROC curves (AUC) were determined for fluid responsiveness (>10% volume expansion-induced increase in CO) prediction. In 112 patients (19% with arrhythmia), changes in noninvasive systolic AP during PLR (noninvasiveΔ(PLR)SAP) only predicted fluid responsiveness (cutoff 17%, n=21, positive likelihood ratio [LR] of 26 [18-38]), not unresponsiveness. If PLR-induced change in central venous pressure (CVP) was at least of 2 mm Hg (n=60), suggesting that PLR succeeded in altering cardiac preload, noninvasiveΔ(PLR)SAP performance was good: AUC of 0.94 [0.85-0.98], positive and negative LRs of 5.7 [4.6-6.8] and 0.07 [0.009-0.5], respectively, for a cutoff of 9%. Of note, invasive AP-derived indices did not outperform noninvasiveΔ(PLR)SAP. Regardless of CVP (i.e., during "blind PLR"), noninvasiveΔ(PLR)SAP more than 17% reliably identified fluid responders. During "CVP-guided PLR", in case of sufficient change in CVP, noninvasiveΔ(PLR)SAP performed better (cutoff of 9%). These findings, in sedated patients who had already undergone volume expansion and/or catecholamines, have to be verified during the early phase of circulatory failure (before an arterial line and/or a CO measuring device is placed). Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  10. Plasma drug concentrations and clinical effects of a peripheral alpha-2-adrenoceptor antagonist, MK-467, in horses sedated with detomidine.

    PubMed

    Vainionpää, Mari H; Raekallio, Marja R; Pakkanen, Soile A E; Ranta-Panula, Ville; Rinne, Valtteri M; Scheinin, Mika; Vainio, Outi M

    2013-05-01

    To investigate plasma drug concentrations and the effect of MK-467 (L-659'066) on sedation, heart rate and gut motility in horses sedated with intravenous (IV) detomidine. Experimental randomized blinded crossover study. Six healthy horses. Detomidine (10 μg kg(-1) IV) was administered alone (DET) and in combination with MK-467 (250 μg kg(-1) IV; DET + MK). The level of sedation and intestinal sounds were scored. Heart rate (HR) and central venous pressure (CVP) were measured. Blood was collected to determine plasma drug concentrations. Repeated measures anova was used for HR, CVP and intestinal sounds, and the Student's t-test for pairwise comparisons between treatments for the area under the time-sedation curve (AUCsed ) and pharmacokinetic parameters. Significance was set at p < 0.05. A significant reduction in HR was detected after DET, and HR was significantly higher after DET + MK than DET alone. No heart blocks were detected in any DET + MK treated horses. DET + MK attenuated the early increase in CVP detected after DET, but later the CVP decreased with both treatments. Detomidine-induced intestinal hypomotility was prevented by MK-467. AUCsed was significantly higher with DET than DET + MK, but maximal sedations scores did not differ significantly between treatments. MK-467 lowered the AUC of the plasma concentration of detomidine, and increased its volume of distribution and clearance. MK-467 prevented detomidine induced bradycardia and intestinal hypomotility. MK-467 did not affect the clinical quality of detomidine-induced sedation, but the duration of the effect was reduced, which may have been caused by the effects of MK-467 on the plasma concentration of detomidine. MK-467 may be useful clinically in the prevention of certain peripheral side effects of detomidine in horses. © 2013 The Authors. Veterinary Anaesthesia and Analgesia © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  11. Effect of intraoperative transesophageal Doppler-guided fluid therapy versus central venous pressure-guided fluid therapy on renal allograft outcome in patients undergoing living donor renal transplant surgery: a comparative study.

    PubMed

    Srivastava, Divya; Sahu, Sandeep; Chandra, Abhilash; Tiwari, Tanmay; Kumar, Sanjay; Singh, P K

    2015-12-01

    Transesophageal Doppler (TED)-guided intraoperative fluid therapy has shown to noninvasively optimize intravascular volume and reduce postoperative morbidity. The aim of this study was to compare the effects of Doppler-guided intraoperative fluid administration and central venous pressure (CVP)-guided fluid therapy on renal allograft outcome and postoperative complications. A prospective nonrandomized active controlled study was conducted on end-stage renal disease patients scheduled for living donor renal transplant surgery. 110 patients received intraoperative fluid guided by corrected flow time (FTc) and variation in stroke volume values obtained by continuous TED monitoring. Data of 104 patients in whom intraoperative fluid administration was guided by CVP values were retrospectively obtained for a control. The amount of intraoperative fluid given in the study group (12.20 ± 4.24 ml/kg/h) was significantly lower than in the controls (22.21 ± 4.67 ml/kg/h). The amount of colloid used was also significantly less and fewer recipients were seen to require colloid (69 vs 85%). The mean arterial pressures were comparable throughout. CVP reached was 7.18 ± 3.17 mmHg in the study group. It was significantly higher in the controls (13.42 ± 3.12 mmHg). The postoperative graft function and rate of dysfunction were comparable. Side-effects like postoperative dyspnoea (4.8 vs 0%) and tissue edema (9.6 vs 2.7%) were higher in the controls. FTc-guided intraoperative fluid therapy achieved the same rate of immediate graft function as CVP-guided fluid therapy but used a significantly less amount of fluid. The incidence of postoperative complications related to fluid overload was also reduced. The use of TED may replace invasive central line insertions in the future.

  12. A to Z List of Cancer Drugs

    MedlinePlus

    ... T) Purinethol (Mercaptopurine) Purixan (Mercaptopurine) Q [No Entries] R Radium 223 Dichloride Raloxifene Hydrochloride Ramucirumab Rasburicase R-CHOP R-CVP Recombinant Human Papillomavirus (HPV) Bivalent ...

  13. Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure.

    PubMed

    Bellemare, Patrick; Goldberg, Peter; Magder, Sheldon A

    2007-11-01

    A readily available assessment of changes in pleural pressure would be useful for ventilator and fluid management in critically ill patients. We examined whether changes in pulmonary artery occlusion pressure (Ppao) adequately reflect respiratory changes in pleural pressure as assessed by changes in intraesophageal balloon pressure (Peso). We studied patients who had a pulmonary catheter and esophageal balloon surrounding a nasogastric tube as part of their care (n=24). We compared changes in Ppao (dPpao) to changes in Peso (dPeso) by Bland-Altman and regression analysis. Adequacy of balloon placement was assessed by performing Mueller maneuvers and adjusting the position to achieve a ratio of dPeso to change in tracheal pressure (dPtr) of 0.85 or higher. This was achieved in only 14 of the 24 subjects. We also compared dCVP to dPeso. The dPpao during spontaneous breaths and positive pressure breaths gave a good estimate of Peso but generally underestimated dPeso (bias=2.2 +8.2 and -3.9 cmH2O for the whole group). The dCVP was not as good a predictor (bias=2.9 +10.3 and -4.6). In patients who have a pulmonary artery catheter in place dPpao gives a lower estimate of changes in pleural pressure and may be more reliable than dPeso. The dCVP is a less reliable predictor than changes in pleural pressure.

  14. Microstructure-sensitive Crystal Viscoplasticity for Ni-base Superalloys Targeting Long-term Creep-Fatigue Interaction Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neu, Richard W.

    The aim of this project is to develop a microstructure-sensitive crystal viscoplasticity (CVP) model for single-crystal Ni-base superalloys to model the behavior of the material and components in the hot gas path sections of industrial gas turbines (IGT). Microstructure degradation associated with aging critical to predicting long-term creep-fatigue interactions will be embedded into the model through the γ' precipitate morphology evolution by coupling the coarsening drivers and kinetics into the constitutive equations of the CVP model. Model parameters will be determined using new experimental protocols that involve systematically artificially aging the alloy under different stress conditions to determine the relationshipmore » between the size and morphology g' precipitates on the creep and thermomechanical fatigue response.« less

  15. Microstructure-sensitive Crystal Viscoelasticity for Ni-base Superalloys Targeting Long-term Creep-Fatigue Interaction Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neu, Richard W

    The aim of this project is to develop a microstructure-sensitive crystal viscoplasticity (CVP) model for single-crystal Ni-base superalloys to model the behavior of the material and components in the hot gas path sections of industrial gas turbines (IGT). Microstructure degradation associated with aging critical to predicting long-term creep-fatigue interactions will be embedded into the model through the γ' precipitate morphology evolution by coupling the coarsening drivers and kinetics into the constitutive equations of the CVP model. Model parameters will be determined using new experimental protocols that involve systematically artificially aging the alloy under different stress conditions to determine the relationshipmore » between the size and morphology g' precipitates on the creep and thermomechanical fatigue response.« less

  16. Angio-OCT de la zona avascular foveal en ojos con oclusión venosa de la retina.

    PubMed

    Wons, Juliana; Pfau, Maximilian; Wirth, Magdalena A; Freiberg, Florentina J; Becker, Matthias D; Michels, Stephan

    2017-07-11

    Objetivo: El objetivo del estudio comprendía visualizar y cuantificar las alteraciones patológicas de la zona avascular foveal (ZAF) mediante angio-OCT en ojos con oclusión venosa de la retina (OVR) en comparación con el ojo contralateral sano. Procedimientos: La angio-OCT se llevó a cabo mediante el sistema Avanti® RTVue 100 XR (Optovue Inc., Fremont, Calif., EE. UU.). Los bordes de la capa vascular superficial (CVS) se definieron como 3 μm por debajo de la membrana limitante interna y 15 μm por debajo de la capa plexiforme interna y, para la capa vascular profunda (CVP), como 15 y 70 μm por debajo de la membrana limitante interna y de la capa plexiforme interna, respectivamente. La longitud de la ZAF horizontal, vertical y máxima de la CVS y la CVP en cada ojo se midió de forma manual. Además, se midió el ángulo entre el diámetro máximo de la ZAF y el plano papilomacular. Resultados: La angio-OCT representó los defectos dentro de la vasculatura en el área perifoveal en ojos con oclusión de rama venosa de la retina (ORVR; n = 11) y con oclusión de la vena central de la retina (OVCR; n = 8). Esto resultó en un crecimiento del diámetro máximo de la ZAF en ojos con OVR (n = 19) en comparación con el ojo contralateral (n = 19; 921 ± 213 frente a 724 ± 145 µm; p = 0,008). Además, se observó una correlación significativa entre la mejor agudeza visual corregida (MAVC) y el diámetro máximo de la ZAF en la CVP (ρ de Spearman = -0,423, p < 0,01). Por último, en los ojos con OVR, el ángulo entre el plano papilomacular y el diámetro máximo de la ZAF se dio tan solo en el 21,05% (CVS) y en el 15,79% (CVP) de los casos a 0 ± 15 ó 90 ± 15°, respectivamente. En ojos sanos, estos ángulos (que supuestamente representan una configuración de la ZAF regular) fueron más prevalentes (CVS 68,42 frente a 21,05%, p = 0,003; CVP 73,68 frente a 15,79%, p < 0,001). Conclusiones: La angio-OCT muestra alteraciones morfológicas de la ZAF en ojos con OVCR y ORVR. La correlación del diámetro máximo de la ZAF con la MAVC indica que estas alteraciones resultan funcionalmente relevantes. © 2017 S. Karger AG, Basel.

  17. Peripheral Edema, Central Venous Pressure, and Risk of AKI in Critical Illness

    PubMed Central

    Chen, Kenneth P.; Cavender, Susan; Lee, Joon; Feng, Mengling; Mark, Roger G.; Celi, Leo Anthony; Mukamal, Kenneth J.

    2016-01-01

    Background and objectives Although venous congestion has been linked to renal dysfunction in heart failure, its significance in a broader context has not been investigated. Design, setting, participants, & measurements Using an inception cohort of 12,778 critically ill adult patients admitted to an urban tertiary medical center between 2001 and 2008, we examined whether the presence of peripheral edema on admission physical examination was associated with an increased risk of AKI within the first 7 days of critical illness. In addition, in those with admission central venous pressure (CVP) measurements, we examined the association of CVPs with subsequent AKI. AKI was defined using the Kidney Disease Improving Global Outcomes criteria. Results Of the 18% (n=2338) of patients with peripheral edema on admission, 27% (n=631) developed AKI, compared with 16% (n=1713) of those without peripheral edema. In a model that included adjustment for comorbidities, severity of illness, and the presence of pulmonary edema, peripheral edema was associated with a 30% higher risk of AKI (95% confidence interval [95% CI], 1.15 to 1.46; P<0.001), whereas pulmonary edema was not significantly related to risk. Peripheral edema was also associated with a 13% higher adjusted risk of a higher AKI stage (95% CI, 1.07 to 1.20; P<0.001). Furthermore, levels of trace, 1+, 2+, and 3+ edema were associated with 34% (95% CI, 1.10 to 1.65), 17% (95% CI, 0.96 to 1.14), 47% (95% CI, 1.18 to 1.83), and 57% (95% CI, 1.07 to 2.31) higher adjusted risk of AKI, respectively, compared with edema-free patients. In the 4761 patients with admission CVP measurements, each 1 cm H2O higher CVP was associated with a 2% higher adjusted risk of AKI (95% CI, 1.00 to 1.03; P=0.02). Conclusions Venous congestion, as manifested as either peripheral edema or increased CVP, is directly associated with AKI in critically ill patients. Whether treatment of venous congestion with diuretics can modify this risk will require further study. PMID:26787777

  18. Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study.

    PubMed

    Zhou, Jing; Han, Yi

    2016-01-01

    To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored with classical monitor and a pulse co-oximeter, with pulse sensors attached to patients' index fingers. Hemodynamic data [heart rate (HR), perfusion index (PI), PVI, central venous pressure (CVP), mean arterial pressure (MAP), peripheral blood oxygen saturation (SPO2), peripheral blood oxygen content (SPOC) and peripheral blood hemoglobin (SPHB)] as well as the respiratory data [respiratory rate (RR), tidal volume (VT), RSC and controlled airway pressure] were recorded for 15 min each at 3 different levels of PEEP (0, 5 and 10 cmH2O). Different levels of PEEP (0, 5 and 10 cmH2O) had no obvious effect on RR, HR, MAP, SPO2 and SPOC. However, 10 cmH2O PEEP induced significant hemodynamic disturbances, including decreases of PI, and increases of both PVI and CVP. Meanwhile, 5 cmH2O PEEP induced no significant changes on hemodynamics such as CVP, PI and PVI, but improved the RSC. RSC and PVI may be useful in detecting the hemodynamic and respiratory effects of PEEP, thus may help clinicians individualize PEEP settings in mechanically ventilated patients.

  19. Effect and Outcome of Intraoperative Fluid Restriction in Living Liver Donor Hepatectomy.

    PubMed

    Wang, Chih-Hsien; Cheng, Kwok-Wai; Chen, Chao-Long; Wu, Shao-Chun; Shih, Tsung-Hsiao; Yang, Sheng-Chun; Lee, Ying-En; Jawan, Bruno; Huang, Chiu-En; Juang, Sin-Ei; Huang, Chia-Jung

    2017-11-10

    BACKGROUND The purpose of this study was to evaluate the effect and outcome of intraoperative fluid restriction in living liver donor hepatectomy, regarding changes in intraoperative CVP levels, blood loss, and postoperative renal function. MATERIAL AND METHODS The charts of 167 patients were reviewed and analyzed retrospectively. Intraoperative central venous pressure levels, blood loss, fluids infused, and urine output per hour, before and after the liver allograft procurement, were calculated. Perioperative renal functions were also analyzed. RESULTS Fluid infused before and after liver allograft procurement was 3.21±1.5 and 9.0±3.9 mL/Kg/h and urine output was 1.5±0.7 and 1.8±1.4 mL/Kg/h, respectively. Intraoperative estimated blood loss was 91.3±78.9 mL. No patients required blood transfusion. Their preoperative and postoperative hemoglobin were 12.3±2.7 and 11.7±1.7 g/dL. CVP levels decreased gradually from 10.4±3.0 to a low of 8.1±1.9 mmHg at the time of transection of the liver parenchyma. Renal functions were not significantly affected based on the determination of BUN and creatinine levels. CONCLUSIONS The methods used to lower CVP are moderate and slow, with 2 main goals achieved: minimal blood loss (91.3±78.9 ml) and no blood transfusion. Furthermore, it did not have any negative effect on renal function.

  20. Feasibility of remote real-time guidance of a cardiac examination performed by novices using a pocket-sized ultrasound device.

    PubMed

    Mai, Tuan V; Ahn, David T; Phillips, Colin T; Agan, Donna L; Kimura, Bruce J

    2013-01-01

    Background. The potential of pocket-sized ultrasound devices (PUDs) to improve global healthcare delivery is limited by the lack of a suitable imaging protocol and trained users. Therefore, we investigated the feasibility of performing a brief, evidence-based cardiac limited ultrasound exam (CLUE) through wireless guidance of novice users. Methods. Three trainees applied PUDs on 27 subjects while directed by an off-site cardiologist to obtain a CLUE to screen for LV systolic dysfunction (LVSD), LA enlargement (LAE), ultrasound lung comets (ULC+), and elevated CVP (eCVP). Real-time remote audiovisual guidance and interpretation by the cardiologist were performed using the iPhone 4/iPod (FaceTime, Apple, Inc.) attached to the PUD and transmitted data wirelessly. Accuracy and technical quality of transmitted images were compared to on-site, gold-standard echo thresholds. Results. Novice versus sonographer imaging yielded technically adequate views in 122/135 (90%) versus 130/135 (96%) (P < 0.05). CLUE's combined SN, SP, and ACC were 0.67, 0.96, and 0.90. Technical adequacy (%) and accuracy for each abnormality (n) were LVSD (85%, 0.93, n = 5), LAE (89%, 0.74, n = 16), ULC+ (100%, 0.94, n = 5), and eCVP (78%, 0.91, n = 1). Conclusion. A novice can perform the CLUE using PUD when wirelessly guided by an expert. This method could facilitate PUD use for off-site bedside medical decision making and triaging of patients.

  1. Treatment of gastric marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue with rituximab, cyclophosphamide, vincristine and prednisone.

    PubMed

    Aguiar-Bujanda, David; Llorca-Mártinez, Ignacio; Rivero-Vera, José C; Blanco-Sánchez, María J; Jiménez-Gallego, Pedro; Mori-De Santiago, Marta; Limeres-Gonzalez, Miguel A; Cabrera-Marrero, José C; Hernández-Sosa, María; Galván-Ruíz, Saray; Hernández-Sarmiento, Samuel; Saura Grau, Salvador; Bohn-Sarmiento, Uriel

    2014-09-01

    There is no standard treatment for patients with gastric marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT lymphoma) who are resistant to, or ineligible for, anti-Helicobacter pylori (anti-HP) therapy. In this study, we investigated the activity of the rituximab, cyclophosphamide, vincristine and prednisone (R-CVP) regimen in patients with gastric MALT lymphoma. Patients were included provided they had untreated gastric MALT lymphoma (except for anti-HP therapy) and were resistant to, or ineligible for, anti-HP therapy. Treatment plan consisted of six to eight 21-day cycles of the R-CVP chemotherapy regimen. Toxicity, response, relapse and survival were evaluated. Twenty patients (12 women and 8 men) were included in the analyses with median age of 59 years. Thirteen patients (65%) had stage I tumours, and seven patients (35%) had stages II-IV tumours. The overall response rate was 100%, with 19 (95%) complete responses and one (5%) partial response. Regimen toxicity was mild and mainly hematological, and no cases of gastric bleeding or perforation occurred. After a median follow-up of 56.3 months, three patients had relapsed, and 19 patients remained alive (specific lymphoma survival 100%), of whom 17 had no evidence of disease. In our experience, the R-CVP regimen is a well-tolerated and effective treatment for patients with gastric MALT lymphoma who are resistant to, or ineligible for, anti-HP therapy. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Sequential modulation of cardiac autonomic control induced by cardiopulmonary and arterial baroreflex mechanisms

    NASA Technical Reports Server (NTRS)

    Furlan, R.; Jacob, G.; Palazzolo, L.; Rimoldi, A.; Diedrich, A.; Harris, P. A.; Porta, A.; Malliani, A.; Mosqueda-Garcia, R.; Robertson, D.

    2001-01-01

    BACKGROUND: Nonhypotensive lower body negative pressure (LBNP) induces a reflex increase in forearm vascular resistance and muscle sympathetic neural discharge without affecting mean heart rate. We tested the hypothesis that a reflex change of the autonomic modulation of heartbeat might arise during low intensity LBNP without changes of mean heart rate. METHODS AND RESULTS: Ten healthy volunteers underwent plasma catecholamine evaluation and a continuous recording of ECG, finger blood pressure, respiratory activity, and central venous pressure (CVP) during increasing levels of LBNP up to -40 mm Hg. Spectrum and cross-spectrum analyses assessed the changes in the spontaneous variability of R-R interval, respiration, systolic arterial pressure (SAP), and CVP and in the gain (alpha(LF)) of arterial baroreflex control of heart rate. Baroreceptor sensitivity was also evaluated by the SAP/R-R spontaneous sequences technique. LBNP began decreasing significantly: CVP at -10, R-R interval at -20, SAP at -40, and the indexes alpha(LF) and baroreceptor sensitivity at -30 and -20 mm Hg, compared with baseline conditions. Plasma norepinephrine increased significantly at -20 mm Hg. The normalized low-frequency component of R-R variability (LF(R-R)) progressively increased and was significantly higher than in the control condition at -15 mm Hg. CONCLUSIONS: Nonhypotensive LBNP elicits a reflex increase of cardiac sympathetic modulation, as evaluated by LF(R-R), which precedes the changes in the hemodynamics and in the indexes of arterial baroreflex control.

  3. Efficacy and safety of ultrasound-guided placement of central venous port systems via the right internal jugular vein in elderly oncologic patients: our single-center experience and protocol.

    PubMed

    Canfora, Alfonso; Mauriello, Claudio; Ferronetti, Antonio; Marte, Gianpaolo; Di Maio, Vittorio; Ciorra, Guido; Esposito, Maria Grazia; Giuliano, Maria Elena; Fregola, Giovanni; Barra, Luigi; Cuzzovaglia, Salvatore; Bottino, Vincenzo; Maida, Pietro

    2017-02-01

    Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.

  4. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akahane, Akio, E-mail: a.akahane@gmail.com; Sone, Miyuki; Ehara, Shigeru

    2011-12-15

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achievedmore » in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.« less

  5. Riverine based eco-tourism: Trinity River non-market benefits estimates

    USGS Publications Warehouse

    Douglas, A.J.; Taylor, J.G.

    1998-01-01

    California's Central Valley Project (CVP) was approved by voters in a statewide referendum in 1933. CVP referendum approval initiated funding for construction of important water development projects that had far reaching effects on regional water supplies. The construction of Trinity Dam in 1963 and the subsequent transbasin diversion of Trinity River flow was one of several CVP projects that had noteworthy adverse environmental and regional economic impacts. The Trinity River is the largest tributary of the Klamath River, and has its headwaters in the Trinity Alps of north-central California. After the construction of Trinity Dam in 1963, 90% of the Trinity River flow at Lewiston was moved to the Sacramento River via the Clear Creek Tunnel. Before 1963, the Trinity River was a major recreation resource of Northern California. The loss of streamflow has had a marked adverse impact on Trinity River-related recreation activities and the size and robustness of Trinity River salmon, steelhead, shad, and sturgeon runs. Trinity River water produces hydropower during its transit via Bureau of Reclamation canals and pumps to the northern San Joaquin Valley, where it is used for irrigated agriculture. The benefits provided by Trinity River instream flow-related environmental amenities were estimated with the travel cost method (TCM). Trinity River non-market benefits are about $406 million per annum, while the social cost of sending water down the Trinity River ranges from $17 to $42 million per annum, depending on the exact flow. We also discuss the relative magnitude of Trinity River survey data contingent value method (CVM) benefits estimates.

  6. Treatment of hepatorenal syndrome as defined by the international ascites club by albumin and furosemide infusion according to the central venous pressure: a prospective pilot study.

    PubMed

    Péron, Jean-Marie; Bureau, Christophe; Gonzalez, Laurent; Garcia-Ricard, Franck; de Soyres, Olivier; Dupuis, Emmanuel; Alric, Laurent; Pourrat, Jacques; Vinel, Jean-Pierre

    2005-12-01

    Hepatorenal syndrome (HRS) is a functional renal failure that occurs late during cirrhosis. The prognosis is extremely poor with a mean survival of 1.7 wks from the time of diagnosis. The aim of the present study was to examine the effects of albumin and furosemide administration tailored to central venous pressure (CVP) on renal function and clinical outcome. We treated 20 consecutive patients with HRS. Albumin was given to increase and/or maintain CVP above 3 cm H(2)O. If diuresis remained below 50 mL/h despite effective volume expansion, furosemide was administrated. Patients were considered responders and treatment was discontinued when creatinine clearance rose above 40 mL/min or serum creatinine fell under 132 mumol/L. The need for albumin varied from patient to patient (extremes 40-600 g) and in the same patient from day to day. All but one needed furosemide. Eleven patients (55%) responded to treatment. In this population, diuresis, serum creatinine, and creatinine clearance were all significantly improved. Creatinine clearance at baseline was predictive of treatment efficacy. Survival increased in these patients compared to nonresponders defined as patients with no improvement in renal function (259 days +/- 113 compared to 14 days +/- 3, p < 0.0005). Response to treatment and the type of HRS were the only variables with an independent prognostic value. This study shows that HRS as defined by the International Ascites Club can be treated by albumin administration alone or with furosemide given according to the patient's specific need using CVP.

  7. An artificial right ventricle for failing fontan: in vitro and computational study.

    PubMed

    Lacour-Gayet, François G; Lanning, Craig J; Stoica, Serban; Wang, Rui; Rech, Bryan A; Goldberg, Steven; Shandas, Robin

    2009-07-01

    The aim of this study is to develop a destination low-pressure artificial right ventricle (ARV) to correct the impaired hemodynamics in the failing Fontan circulation. An in vitro model circuit of the Fontan circulation was created to reproduce the hemodynamics of the failing Fontan and test ARV performance under various central venous pressures (CVP) and flows. A novel geometry of the extracardiac conduit was designed to adapt to the need of the pump. The ARV was a low-pressure axial flow pump designed to produce a low suction inflow pressure and moderate outflow increase. With the power off, the passive forward gradient across the propeller is 2 mm Hg at 4.5 L/min. The ARV would require 4 watts at a rotation of 5000 rpm. To examine the shear loading on the red blood cells, virtual particles were injected upstream of the ARV inducer and tracked by computerized modeling. The effect of the ARV on the failing Fontan was studied at various CVP pressures and flows, and under constant values of lung resistances and left atrial pressure set respectively to 2.5 Woods Units and 7 mm Hg. The CVP pressures decreased respectively from 25, 22.5, 20, 17.5, 15, and 10 mm Hg to a minimal value of 2 to 5 mm Hg with a pump speed varying from 1700 to 4500 rpm. The pulmonary artery pressures increased moderately between 12.5 and 25 mm Hg at 4500 rpm. Cardiac output at 4500 rpm was increased by an average gain of 2 L/min. The average blood damage index was 0.92%, far below the 5% value considered to cause hemolysis. The flow structure produced by the pump was suitable. The performance of this novel low-pressure ARV was satisfactory, showing good decrease of CVP pressures, a moderate increase of pulmonary artery pressures, adequate increase of cardiac output, and minimal hemolysis. The use of a mock Fontan model circuit facilitates device prototyping and design to a far greater extent than can be achieved using animal studies, and is an essential first step for rapid design iteration of a novel ARV device. The next steps are the manufacturing of this device, including an electromagnetic engine, a regulatory system, and further testing the device in a survival animal experiment.

  8. The anatomy and physiology of the terminal thoracic duct and ostial valve in health and disease: potential implications for intervention.

    PubMed

    Ratnayake, Chathura Bathiya Bandara; Escott, Alistair Brian James; Phillips, Anthony Ronald John; Windsor, John Albert

    2018-07-01

    The thoracic duct (TD) transports lymph drained from the body to the venous system in the neck via the lymphovenous junction. There has been increased interest in the TD lymph (including gut lymph) because of its putative role in the promotion of systemic inflammation and organ dysfunction during acute and critical illness. Minimally invasive TD cannulation has recently been described as a potential method to access TD lymph for investigation. However, marked anatomical variability exists in the terminal segment and the physiology regarding the ostial valve and terminal TD is poorly understood. A systematic review was conducted using three databases from 1909 until May 2017. Human and animal studies were included and data from surgical, radiological and cadaveric studies were retrieved. Sixty-three articles from the last 108 years were included in the analysis. The terminal TD exists as a single duct in its terminal course in 72% of cases and 13% have multiple terminations: double (8.5%), triple (1.8%) and quadruple (2.2%). The ostial valve functions to regulate flow in relation to the respiratory cycle. The patency of this valve found at the lymphovenous junction opening, is determined by venous wall tension. During inspiration, central venous pressure (CVP) falls and the valve cusps collapse to allow antegrade flow of lymph into the vein. During early expiration when CVP and venous wall tension rises, the ostial valve leaflets cover the opening of the lymphovenous junction preventing antegrade lymph flow. During chronic disease states associated with an elevated mean CVP (e.g. in heart failure or cirrhosis), there is a limitation of flow across the lymphovenous junction. Although lymph production is increased in both heart failure and cirrhosis, TD lymph outflow across the lymphovenous junction is unable to compensate for this increase. In conclusion the terminal TD shows marked anatomical variability and TD lymph flow is controlled at the ostial valve, which responds to changes in CVP. This information is relevant to techniques for cannulating the TD, with the aid of minimally invasive methods and high resolution ultrasonography, to enable longitudinal physiology and lymph composition studies in awake patients with both acute and chronic disease. © 2018 Anatomical Society.

  9. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach.

    PubMed

    Biais, Matthieu; Ehrmann, Stephan; Mari, Arnaud; Conte, Benjamin; Mahjoub, Yazine; Desebbe, Olivier; Pottecher, Julien; Lakhal, Karim; Benzekri-Lefevre, Dalila; Molinari, Nicolas; Boulain, Thierry; Lefrant, Jean-Yves; Muller, Laurent

    2014-11-04

    Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P<0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg(-1) and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.

  10. Effect of changes in PCO2 and body positions on intraocular pressure during general anaesthesia.

    PubMed

    Hvidberg, A; Kessing, S V; Fernandes, A

    1981-08-01

    Elevated arterial carbon dioxide tension, induced by the administration of CO2 via the respiratory air or by hypoventilation, entailed a gradual increase in the IOP in patients without eye diseases under general anaesthesia. A sudden cessation of CO2 administration or hyperventilation caused such a rapid, simultaneous fall in IOP to values below the initial level that the pressure variations must be of vascular nature, presumably related to changes in choroidal blood volume. The above-mentioned procedures always cause a change in the central venous pressure (CVP) simultaneously with the IOP changes. Alterations of the CVP induced by hydrostatic factors in postural changes, placing the head 15 degrees above or below the horizontal level while keeping the PaCO2 constant, caused IOP changes of the same configuration and magnitude as described above. It is concluded, therefore, that presumably the CO2-conditioned IOP changes are due predominantly to changes in central venous pressure, being one link in a CO2-conditioned action upon the general circulation, entailing passive secondary changes in the choroidal venous blood volume and thereby an influence upon the IOP. On the basis of the present results it appears rational to recommend hyperventilation to keep the PaCO2 between 25 and 30 mm and a 15 degree anti-Trendelenburg position in operations on the eye under general anaesthesia, since both procedures afford a low central venous pressure and consequently a low pressure in the posterior segment of the eye, with its attendant advantages as regards vitreous complications and the insertion of intraocular lenses. Owing to the risk of an unacceptable fall in BP in the combined procedure, a frequent checking of the BP is needed.

  11. [Analysis and evaluation of the visual effort in remote-control public traffic operators working with computer-based equipments].

    PubMed

    Gullà, F; Zambelli, P; Bergamaschi, A; Piccoli, B

    2007-01-01

    The aim of this study is the objective evaluation of the visual effort in 6 public traffic controllers (4 male, 2 female, mean age 29,6), by means of electronic equipment. The electronic equipment quantify the observation distance and the observation time for each controller's occupational visual field. The quantification of these parameters is obtained by the emission of ultrasound at 40 KHz from an emission sensor (placed by the VDT screen) and the ultrasound reception by means of a receiving sensor (placed on the operator's head). The travelling time of the ultrasound (US), as the air speed is known and costant (about 340 m/s), it is used to calculate the distance between the emitting and the receiving sensor. The results show that the visual acuity required is of average level, while accommodation's and convergence's effort vary from average to intense (depending on the visual characteristics of the operator considered), ranging from 26,41 and 43,92% of accommodation and convergence available in each operator. The time actually spent in "near observation within the c.v.p." (Tscr) was maintained in a range from 2h 54' and 4h 05'.

  12. Chronic orthostatic intolerance: a disorder with discordant cardiac and vascular sympathetic control

    NASA Technical Reports Server (NTRS)

    Furlan, R.; Jacob, G.; Snell, M.; Robertson, D.; Porta, A.; Harris, P.; Mosqueda-Garcia, R.

    1998-01-01

    BACKGROUND: Chronic orthostatic intolerance (COI) is a debilitating autonomic condition in young adults. Its neurohumoral and hemodynamic profiles suggest possible alterations of postural sympathetic function and of baroreflex control of heart rate (HR). METHODS AND RESULTS: In 16 COI patients and 16 healthy volunteers, intra-arterial blood pressure (BP), ECG, central venous pressure (CVP), and muscle sympathetic nerve activity (MSNA) were recorded at rest and during 75 degrees tilt. Spectral analysis of RR interval and systolic arterial pressure (SAP) variabilities provided indices of sympathovagal modulation of the sinoatrial node (ratio of low-frequency to high-frequency components, LF/HF) and of sympathetic vasomotor control (LFSAP). Baroreflex mechanisms were assessed (1) by the slope of the regression line obtained from changes of RR interval and MSNA evoked by pharmacologically induced alterations in BP and (2) by the index alpha, obtained from cross-spectral analysis of RR and SAP variabilities. At rest, HR, MSNA, LF/HF, and LFSAP were higher in COI patients, whereas BP and CVP were similar in the two groups. During tilt, BP did not change and CVP fell by the same extent in the 2 groups; the increase of HR and LF/HF was more pronounced in COI patients. Conversely, the increase of MSNA was lower in COI than in control subjects. Baroreflex sensitivity was similar in COI and control subjects at rest; tilt reduced alpha similarly in both groups. CONCLUSIONS: COI is characterized by an overall enhancement of noradrenergic tone at rest and by a blunted postganglionic sympathetic response to standing, with a compensatory cardiac sympathetic overactivity. Baroreflex mechanisms maintain their functional responsiveness. These data suggest that in COI, the functional distribution of central sympathetic tone to the heart and vasculature is abnormal.

  13. Characterization of the immune response to canine parvovirus induced by vaccination with chimaeric plant viruses.

    PubMed

    Nicholas, Benjamin L; Brennan, F R; Martinez-Torrecuadrada, J L; Casal, J I; Hamilton, W D; Wakelin, D

    2002-06-21

    NIH mice were vaccinated subcutaneously or intranasally with chimaeric cow pea mosaic virus (CPMV) constructs expressing a 17-mer peptide sequence from canine parvovirus (CPV) as monomers or dimers on the small or large protein surface subunits. Responses to the chimaeric virus particles (CVPs) were compared with those of mice immunized with the native virus or with parvovirus peptide conjugated to keyhole limpet haemocyanin (KLH). The characteristics of the immune response to vaccination were examined by measuring serum and mucosal antibody responses in ELISA, in vitro antigen-induced spleen cell proliferation and cytokine responses. Mice made strong antibody responses to the native plant virus and peptide-specific responses to two of the four CVP constructs tested which were approximately 10-fold lower than responses to native plant virus. The immune response generated by the CVP constructs showed a marked TH1 bias, as determined by a predominantly IgG(2a) isotype peptide-specific antibody response and the release of IFN-gamma but not IL-4 or IL-5 from lymphocytes exposed to antigen in vitro. In comparison, parvovirus peptide conjugated to KLH generated an IgG(1)-biased (TH2) response. These data indicate that the presentation of peptides on viral particles could be used to bias the immune response in favor of a TH1 response.Anti-viral and anti-peptide IgA were detected in intestinal and bronchial lavage fluid of immunized mice, demonstrating that a mucosal immune response to CPV can be generated by systemic and mucosal immunization with CVP vaccines. Serum antibody from both subcutaneously-vaccinated and intranasally-vaccinated mice showed neutralizing activity against CPV in vitro.

  14. Effect of priming/booster immunisation protocols on immune response to canine parvovirus peptide induced by vaccination with a chimaeric plant virus construct.

    PubMed

    Nicholas, B L; Brennan, F R; Hamilton, W D O; Wakelin, D

    2003-06-02

    Expression of a 17-mer peptide sequence from canine parvovirus expressed on cowpea mosaic virus (CPMV) to form chimaeric virus particles (CVPs) creates vaccine antigens that elicit strong anti-peptide immune responses in mice. Systemic (subcutaneous, s.c.) immunisation and boosting with such CVP constructs produces IgG(2a) serum antibody responses, while mucosal (intranasal, i.n.) immunisation and boosting elicits intestinal IgA responses. Combinations of systemic and mucosal routes for priming and boosting immunisations were used to examine their influence on the level, type and location of immune response generated to one of these constructs (CVP-1). In all cases, s.c. administration, whether for immunisation or boosting, generated a Th1-biased response, reflected in a predominantly IgG(2a) serum antibody isotype and secretion of IFN-gamma from in vitro-stimulated lymphocytes. Serum antibody responses were greatest in animals primed and boosted subcutaneously, and least in mucosally vaccinated mice. The i.n. exposure also led to IFN-gamma release from in vitro-stimulated cells, but serum IgG(2a) was significantly elevated only in mice primed intranasally and boosted subcutaneously. Peptide- and wild-type CPMV-specific IgA responses in gut lavage fluid were greatest in animals exposed mucosally and least in those primed and boosted subcutaneously or primed subcutaneously and boosted orally. Lymphocytes from immunised mice proliferated in response to in vitro stimulation with CPMV but not with peptide. The predominant secretion of IFN-gamma from all immunising/boosting combinations indicates that the route of vaccination and challenge does not alter the Th1 bias of the response to CVP constructs. However, optimal serum and intestinal antibody responses were achieved by combining s.c. and i.n. administration.

  15. Individual and Joint Expert Judgments as Reference Standards in Artifact Detection

    PubMed Central

    Verduijn, Marion; Peek, Niels; de Keizer, Nicolette F.; van Lieshout, Erik-Jan; de Pont, Anne-Cornelie J.M.; Schultz, Marcus J.; de Jonge, Evert; de Mol, Bas A.J.M.

    2008-01-01

    Objective To investigate the agreement among clinical experts in their judgments of monitoring data with respect to artifacts, and to examine the effect of reference standards that consist of individual and joint expert judgments on the performance of artifact filters. Design Individual judgments of four physicians, a majority vote judgment, and a consensus judgment were obtained for 30 time series of three monitoring variables: mean arterial blood pressure (ABPm), central venous pressure (CVP), and heart rate (HR). The individual and joint judgments were used to tune three existing automated filtering methods and to evaluate the performance of the resulting filters. Measurements The interrater agreement was calculated in terms of positive specific agreement (PSA). The performance of the artifact filters was quantified in terms of sensitivity and positive predictive value (PPV). Results PSA values between 0.33 and 0.85 were observed among clinical experts in their selection of artifacts, with relatively high values for CVP data. Artifact filters developed using judgments of individual experts were found to moderately generalize to new time series and other experts; sensitivity values ranged from 0.40 to 0.60 for ABPm and HR filters (PPV: 0.57–0.84), and from 0.63 to 0.80 for CVP filters (PPV: 0.71–0.86). A higher performance value for the filters was found for the three variable types when joint judgments were used for tuning the filtering methods. Conclusion Given the disagreement among experts in their individual judgment of monitoring data with respect to artifacts, the use of joint reference standards obtained from multiple experts is recommended for development of automatic artifact filters. PMID:18096912

  16. A Coherent vorticity preserving eddy-viscosity correction for Large-Eddy Simulation

    NASA Astrophysics Data System (ADS)

    Chapelier, J.-B.; Wasistho, B.; Scalo, C.

    2018-04-01

    This paper introduces a new approach to Large-Eddy Simulation (LES) where subgrid-scale (SGS) dissipation is applied proportionally to the degree of local spectral broadening, hence mitigated or deactivated in regions dominated by large-scale and/or laminar vortical motion. The proposed coherent-vorticity preserving (CvP) LES methodology is based on the evaluation of the ratio of the test-filtered to resolved (or grid-filtered) enstrophy, σ. Values of σ close to 1 indicate low sub-test-filter turbulent activity, justifying local deactivation of the SGS dissipation. The intensity of the SGS dissipation is progressively increased for σ < 1 which corresponds to a small-scale spectral broadening. The SGS dissipation is then fully activated in developed turbulence characterized by σ ≤σeq, where the value σeq is derived assuming a Kolmogorov spectrum. The proposed approach can be applied to any eddy-viscosity model, is algorithmically simple and computationally inexpensive. LES of Taylor-Green vortex breakdown demonstrates that the CvP methodology improves the performance of traditional, non-dynamic dissipative SGS models, capturing the peak of total turbulent kinetic energy dissipation during transition. Similar accuracy is obtained by adopting Germano's dynamic procedure albeit at more than twice the computational overhead. A CvP-LES of a pair of unstable periodic helical vortices is shown to predict accurately the experimentally observed growth rate using coarse resolutions. The ability of the CvP methodology to dynamically sort the coherent, large-scale motion from the smaller, broadband scales during transition is demonstrated via flow visualizations. LES of compressible channel are carried out and show a good match with a reference DNS.

  17. Comparison of pulmonary artery and central venous pressure waveform measurements via digital and graphic measurement methods.

    PubMed

    Ahrens, T S; Schallom, L

    2001-01-01

    Techniques to measure pulmonary artery (PA) pressure waveforms include digital measurement, graphic measurement, and freeze-cursor measurement. Previous studies reported the inaccuracy of digital and freeze-cursor measurements. However, many of the previous studies were small and did not thoroughly examine the circumstances of when digital measurements might be inaccurate. To compare digital measurements and graphic measurements of PA and central venous pressure (CVP) waveforms in patients with a variety of respiratory patterns, and to compare digital measurements and graphic measurements of CVPs in patients with abnormal or right ventricular waveforms. A total of 928 patients were enrolled in this study. Waveforms from the PA and CVP were collected from each patient. The monitor pressure value (digital measurement) printed on the recorded waveform was compared with the pressure value obtained by a graphic strip recording and measured by one of the primary investigators (graphic measurement). Digital measurements were found to be inaccurate in measuring waveforms in all respiratory categories and in measuring right ventricular waveforms. PA diastolic values and CVP values were the most inaccurately measured waveforms. Digital errors of more than 4 mm Hg were common. There were instances in which the monitor's digital measurement was substantially different from the graphically measured value. This difference has the potential to mislead interpretation of clinical situations. The monitor's ability to occasionally give digital measurement values similar to the graphic measurements may lead to a false sense of security in clinicians. Because the accuracy of the monitor is inconsistent, the bedside clinician should interpret waveforms through use of a graphic recording rather than rely on the digital measurement on the monitor.

  18. Fluid and electrolyte control in simulated and actual spaceflight

    NASA Technical Reports Server (NTRS)

    Leach, C. S.; Johnson, P. C., Jr.

    1985-01-01

    Effects of microgravity on body fluid distribution and electrolyte and hormonal levels of astronauts have been studied since the early manned space missions. Bedrested subjects have been used as controls to separate effects of microgravity from those of hypokinesia. These investigations have led to documentation of the physiological effects of spaceflight and to a unified theory of response to microgravity. During flight, crewmembers have decreased thirst and a net loss of body water, sodium, and potassium. These changes seem to be initiated by passive transfer of extracellular fluid resulting in increased central venous pressure (CVP), to which the homeostatic mechanisms respond. A new equilibrium state is maintained during flight; it does not change in response to negative calcium and nitrogen balances during flight. On reexposure to gravity, profound water and salt retention occurs to replete extracellular fluid. Attempts to avoid cardiac deconditioning by repleting water and salt before leaving microgravity have somewhat ameliorated postural hypotension but have had little effect on CVP, cardiac chamber size or electrolyte dynamics.

  19. Pulmonary edema associated with upper airway obstruction in dogs.

    PubMed

    Algren, J T; Price, R D; Buchino, J J; Stremel, R W

    1993-12-01

    In order to evaluate the effect of acute upper airway obstruction upon pulmonary edema (PE) formation, we studied seven dogs that were subjected to inspiratory obstruction for three hours. Hypoxia was avoided by the administration of supplemental oxygen during the study period. Six dogs developed pulmonary vascular congestion, and four developed histologic findings of PE. Inspiratory intrapleural pressure decreased to -28 +/- 4 mmHg in dogs that developed PE and to -23 +/- 2 mmHg in dogs that did not. Transmural pulmonary artery pressure and pulmonary artery wedge pressure did not increase significantly. Central venous pressure during inspiration (CVPi) increased in all dogs, and CVP at end expiration (CVPe) was significantly higher in dogs with PE. Dogs that developed PE experienced a decrease in cardiac output and an increase in systemic vascular resistance. Furthermore, alveolar ventilation declined in dogs with PE, ultimately resulting in ventilatory failure. Pulmonary edema formation was not preceded by an increase in pulmonary vascular pressures but was associated with higher CVP, pulmonary vascular congestion, and hypercarbia.

  20. Cortical regions associated with orthostatic stress in conscious humans

    NASA Astrophysics Data System (ADS)

    Kimmerly, Derek S.; O'Leary, Debbie D.; Cechetto, Angela; Shoemaker, Kevin J.

    2005-08-01

    The purpose of this study was to determine the cortical structures associated with lower body negative pressure (LBNP)-induced baroreflex control using functional magnetic resonance imaging (fMRI). Heart rate (HR) and LBNP were simultaneously monitored during scanning. Central venous pressure (CVP), muscle sympathetic nerve activity (MSNA) and arterial blood pressure (ABP) were measured on a separate day. Random effects analyses (SPM2) were used to evaluate fMRI signal changes that correlated separately with both LBNP and HR (15 and 35-mmHg versus 5-mmHg LBNP). LBNP at 15- and 35-mmHg decreased CVP and increased MSNA, both P < 0.05 versus baseline) but only LBNP at 35- mmHg elevated HR. ABP was similar at all levels of LBNP . Cortical regions demonstrating increased activity at higher HR and greater LBNP included the right superior posterior insula and the cerebellum. Conversely, bilateral anterior insular cortices, the right anterior cingulate, amygdala, and mediodorsal nucleus of the thalamus showed decreased neural activation.

  1. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    PubMed

    Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C

    2018-06-05

    Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of severe RVF. Post-chest closure CVP and post-chest closure PAPi discriminated severe from nonsevere RVF better than other variables measured, each with an area under the curve of 0.75 (95% CI, 0.64-0.86). Post-chest closure values of CVP and PAPi were significantly associated with severe RVF. Echocardiographic assessment of RV function post-CPB was weakly associated with severe RVF.

  2. Statistical Modeling of Daily Stream Temperature for Mitigating Fish Mortality

    NASA Astrophysics Data System (ADS)

    Caldwell, R. J.; Rajagopalan, B.

    2011-12-01

    Water allocations in the Central Valley Project (CVP) of California require the consideration of short- and long-term needs of many socioeconomic factors including, but not limited to, agriculture, urban use, flood mitigation/control, and environmental concerns. The Endangered Species Act (ESA) ensures that the decision-making process provides sufficient water to limit the impact on protected species, such as salmon, in the Sacramento River Valley. Current decision support tools in the CVP were deemed inadequate by the National Marine Fisheries Service due to the limited temporal resolution of forecasts for monthly stream temperature and fish mortality. Finer scale temporal resolution is necessary to account for the stream temperature variations critical to salmon survival and reproduction. In addition, complementary, long-range tools are needed for monthly and seasonal management of water resources. We will present a Generalized Linear Model (GLM) framework of maximum daily stream temperatures and related attributes, such as: daily stream temperature range, exceedance/non-exceedance of critical threshold temperatures, and the number of hours of exceedance. A suite of predictors that impact stream temperatures are included in the models, including current and prior day values of streamflow, water temperatures of upstream releases from Shasta Dam, air temperature, and precipitation. Monthly models are developed for each stream temperature attribute at the Balls Ferry gauge, an EPA compliance point for meeting temperature criteria. The statistical framework is also coupled with seasonal climate forecasts using a stochastic weather generator to provide ensembles of stream temperature scenarios that can be used for seasonal scale water allocation planning and decisions. Short-term weather forecasts can also be used in the framework to provide near-term scenarios useful for making water release decisions on a daily basis. The framework can be easily translated to other locations and is intended to be a complement to the physical stream temperature modeling efforts that are underway on the river.

  3. 75 FR 25209 - Carbazole Violet Pigment 23 from India: Rescission of Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... from India: Rescission of Administrative Review AGENCY: Import Administration, International Trade... administrative review of the antidumping duty order on carbazole violet pigment 23 (CVP 23) from India for the...-circumstances review. See Carbazole Violet Pigment 23 from India: Initiation of Antidumping Duty Changed...

  4. 76 FR 39436 - Draft Environmental Impact Statement/Environmental Impact Report (EIS/EIR) and Notice of Scoping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... other CVP contractors, to Reclamation's Refuge Water Supply Program (RWSP) for delivery to the San... livestock and/or municipal and industrial uses because of water supply shortages or when full contract... Contractors Water Authority's 25-Year Water Transfer Program 2014 to 2038, California AGENCY: Bureau of...

  5. 75 FR 23239 - Carbazole Violet Pigment 23 From India: Extension of Time Limit for Final Results of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-03

    ... Register the preliminary results of the administrative review of the antidumping duty order on CVP 23 from... DEPARTMENT OF COMMERCE International Trade Administration [A-533-838] Carbazole Violet Pigment 23 From India: Extension of Time Limit for Final Results of Antidumping Duty Administrative Review AGENCY...

  6. 75 FR 13257 - Carbazole Violet Pigment 23 from India: Final Results of the Expedited Five-year (Sunset) Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ...) and finished pigment in the form of presscake and dry color. Pigment dispersions in any form (e.g... DEPARTMENT OF COMMERCE International Trade Administration [C-533-839] Carbazole Violet Pigment 23... countervailing duty (CVD) order on Carbazole Violet Pigment 23 (CVP-23) [[Page 13258

  7. 75 FR 977 - Carbazole Violet Pigment 23 From India: Preliminary Results of Countervailing Duty Administrative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-07

    ... Scheme (DEPBS) The DEPBS program enables exporting companies to earn import duty exemptions in the form... Determination, at ``Duty Entitlement Passbook Scheme.'' Therefore, CVP-23 exporters were eligible to earn DEPBS... the POR under the programs listed below: 1. Export Promotion Capital Goods Scheme (EPCGS). 2. Export...

  8. Acute dimethyl sulfoxide therapy in brain edema. Part 3: effect of a 3-hour infusion.

    PubMed

    Del Bigio, M; James, H E; Camp, P E; Werner, R; Marshall, L F; Tung, H

    1982-01-01

    Albino rabbits with experimental brain edema produced by a combined cryogenic left hemisphere lesion and metabolic 6-aminonicotinamide lesion were administered a 3-hour intravenous infusion of dimethyl sulfoxide (DMSO). Simultaneous recording of intracranial pressure (ICP), systolic arterial pressure (SAP), and central venous pressure (CVP) and electroencephalography were performed while the animals were being ventilated mechanically to produce a constant Pa CO2 value (38-42 torr). At the end of the infusion, the brain water and electrolyte contents were measured. There was a persistent and progressive reduction of ICP during the infusion, the nadir occurring at 3 hours (p less than 0.005 from zero time), with no change in SAP or CVP. There was a reduction of brain water in both hemispheres when compared to untreated controls, but this was significant for the right hemisphere only (p less than 0.005). There was a significant reduction of the brain sodium content for both hemispheres, but no significant change occurred in brain potassium content. The DMSO infusion was effective not only in reducing ICP, but also in sustaining this reduction for 3 hours.

  9. A novel non-uniform control vector parameterization approach with time grid refinement for flight level tracking optimal control problems.

    PubMed

    Liu, Ping; Li, Guodong; Liu, Xinggao; Xiao, Long; Wang, Yalin; Yang, Chunhua; Gui, Weihua

    2018-02-01

    High quality control method is essential for the implementation of aircraft autopilot system. An optimal control problem model considering the safe aerodynamic envelop is therefore established to improve the control quality of aircraft flight level tracking. A novel non-uniform control vector parameterization (CVP) method with time grid refinement is then proposed for solving the optimal control problem. By introducing the Hilbert-Huang transform (HHT) analysis, an efficient time grid refinement approach is presented and an adaptive time grid is automatically obtained. With this refinement, the proposed method needs fewer optimization parameters to achieve better control quality when compared with uniform refinement CVP method, whereas the computational cost is lower. Two well-known flight level altitude tracking problems and one minimum time cost problem are tested as illustrations and the uniform refinement control vector parameterization method is adopted as the comparative base. Numerical results show that the proposed method achieves better performances in terms of optimization accuracy and computation cost; meanwhile, the control quality is efficiently improved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Effectiveness and Tradeoffs between Portfolios of Adaptation Strategies Addressing Future Climate and Socioeconomic Uncertainties in California's Central Valley

    NASA Astrophysics Data System (ADS)

    Tansey, M. K.; Van Lienden, B.; Das, T.; Munevar, A.; Young, C. A.; Flores-Lopez, F.; Huntington, J. L.

    2013-12-01

    The Central Valley of California is one of the major agricultural areas in the United States. The Central Valley Project (CVP) is operated by the Bureau of Reclamation to serve multiple purposes including generating approximately 4.3 million gigawatt hours of hydropower and providing, on average, 5 million acre-feet of water per year to irrigate approximately 3 million acres of land in the Sacramento, San Joaquin, and Tulare Lake basins, 600,000 acre-feet per year of water for urban users, and 800,000 acre-feet of annual supplies for environmental purposes. The development of effective adaptation and mitigation strategies requires assessing multiple risks including potential climate changes as well as uncertainties in future socioeconomic conditions. In this study, a scenario-based analytical approach was employed by combining three potential 21st century socioeconomic futures with six representative climate and sea level change projections developed using a transient hybrid delta ensemble method from an archive of 112 bias corrected spatially downscaled CMIP3 global climate model simulations to form 18 future socioeconomic-climate scenarios. To better simulate the effects of climate changes on agricultural water demands, analyses of historical agricultural meteorological station records were employed to develop estimates of future changes in solar radiation and atmospheric humidity from the GCM simulated temperature and precipitation. Projected changes in atmospheric carbon dioxide were computed directly by weighting SRES emissions scenarios included in each representative climate projection. These results were used as inputs to a calibrated crop water use, growth and yield model to simulate the effects of climate changes on the evapotranspiration and yields of major crops grown in the Central Valley. Existing hydrologic, reservoir operations, water quality, hydropower, greenhouse gas (GHG) emissions and both urban and agricultural economic models were integrated into a suite of decision support tools to assess the impacts of future socioeconomic-climate uncertainties on key performance metrics for the CVP, State Water Project and other Central Valley water management systems under current regulatory requirements. Four thematic portfolios consisting of regional and local adaptation strategies including changes in reservoir operations, increased water conservation, storage and conveyance were developed and simulated to evaluate their potential effectiveness in meeting delivery reliability, water quality, environmental, hydropower, GHG, urban and agricultural economic performance criteria. The results indicate that the portfolios exhibit a considerable range of effectiveness depending on the socioeconomic-climate scenario. For most criteria, the portfolios were more sensitive to climate projections than socioeconomic assumptions. However, the results demonstrate that important tradeoffs occur between portfolios depending on the performance criteria considered.

  11. Oral and vocal fold diadochokinesis in dysphonic women.

    PubMed

    Louzada, Talita; Beraldinelle, Roberta; Berretin-Felix, Giédre; Brasolotto, Alcione Ghedini

    2011-01-01

    The evaluation of oral and vocal fold diadochokinesis (DDK) in individuals with voice disorders may contribute to the understanding of factors that affect the balanced vocal production. Scientific studies that make use of this assessment tool support the knowledge advance of this area, reflecting the development of more appropriate therapeutic planning. To compare the results of oral and vocal fold DDK in dysphonic women and in women without vocal disorders. For this study, 28 voice recordings of women from 19 to 54 years old, diagnosed with dysphonia and submitted to a voice assessment from speech pathologist and otorhinolaryngologist, were used. The control group included 30 nondysphonic women evaluated in prior research from normal adults. The analysis parameters like number and duration of emissions, as well as the regularity of the repetition of syllables "pa", "ta", "ka" and the vowels "a" and "i," were provided by the Advanced Motor Speech Profile program (MSP) Model-5141, version-2.5.2 (KayPentax). The DDK sequence "pataka" was analyzed quantitatively through the Sound Forge 7.0 program, as well as manually with the audio-visual help of sound waves. Average values of oral and vocal fold DDK dysphonic and nondysphonic women were compared using the "t Student" test and were considered significant when p<0.05. The findings showed no significant differences between populations; however, the coefficient of variation of period (CvP) and jitter of period (JittP) average of the "ka," "a" and "i" emissions, respectively, were higher in dysphonic women (CvP=10.42%, 12.79%, 12.05%; JittP=2.05%, 6.05%, 3.63%) compared to the control group (CvP=8.86%; 10.95%, 11.20%; JittP=1.82%, 2.98%, 3.15%). Although the results do not indicate any difficulties in oral and laryngeal motor control in the dysphonic group, the largest instability in vocal fold DDK in the experimental group should be considered, and studies of this ability in individuals with communication disorders must be intensified.

  12. Assembly of the Herpes Simplex Virus Capsid: Preformed Triplexes Bind to the Nascent Capsid

    PubMed Central

    Spencer, Juliet V.; Newcomb, William W.; Thomsen, Darrell R.; Homa, Fred L.; Brown, Jay C.

    1998-01-01

    The herpes simplex virus type 1 (HSV-1) capsid is a T=16 icosahedral shell that forms in the nuclei of infected cells. Capsid assembly also occurs in vitro in reaction mixtures created from insect cell extracts containing recombinant baculovirus-expressed HSV-1 capsid proteins. During capsid formation, the major capsid protein, VP5, and the scaffolding protein, pre-VP22a, condense to form structures that are extended into procapsids by addition of the triplex proteins, VP19C and VP23. We investigated whether triplex proteins bind to the major capsid-scaffold protein complexes as separate polypeptides or as preformed triplexes. Assembly products from reactions lacking one triplex protein were immunoprecipitated and examined for the presence of the other. The results showed that neither triplex protein bound unless both were present, suggesting that interaction between VP19C and VP23 is required before either protein can participate in the assembly process. Sucrose density gradient analysis was employed to determine the sedimentation coefficients of VP19C, VP23, and VP19C-VP23 complexes. The results showed that the two proteins formed a complex with a sedimentation coefficient of 7.2S, a value that is consistent with formation of a VP19C-VP232 heterotrimer. Furthermore, VP23 was observed to have a sedimentation coefficient of 4.9S, suggesting that this protein exists as a dimer in solution. Deletion analysis of VP19C revealed two domains that may be required for attachment of the triplex to major capsid-scaffold protein complexes; none of the deletions disrupted interaction of VP19C with VP23. We propose that preformed triplexes (VP19C-VP232 heterotrimers) interact with major capsid-scaffold protein complexes during assembly of the HSV-1 capsid. PMID:9557680

  13. Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress.

    PubMed

    Schlader, Zachary J; Gagnon, Daniel; Lucas, Rebekah A I; Pearson, James; Crandall, Craig G

    2015-02-15

    This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P < 0.001), while saline infusion returned CVP to normothermic levels (5.1 ± 1.7 mmHg; P > 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm(-2)·min(-1)) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm(-2)·min(-1), P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm(-2)·min(-1); P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress. Copyright © 2015 the American Physiological Society.

  14. Interaction between plasma synthetic jet and subsonic turbulent boundary layer

    NASA Astrophysics Data System (ADS)

    Zong, Haohua; Kotsonis, Marios

    2017-04-01

    This paper experimentally investigates the interaction between a plasma synthetic jet (PSJ) and a subsonic turbulent boundary layer (TBL) using a hotwire anemometer and phase-locked particle imaging velocimetry. The PSJ is interacting with a fully developed turbulent boundary layer developing on the flat wall of a square wind tunnel section of 1.7 m length. The Reynolds number based on the freestream velocity (U∞ = 20 m/s) and the boundary layer thickness (δ99 = 34.5 mm) at the location of interaction is 44 400. A large-volume (1696 mm3) three-electrode plasma synthetic jet actuator (PSJA) with a round exit orifice (D = 2 mm) is adopted to produce high-speed (92 m/s) and short-duration (Tjet = 1 ms) pulsed jets. The exit velocity variation of the adopted PSJA in a crossflow is shown to remain almost identical to that in quiescent conditions. However, the flow structures emanating from the interaction between the PSJ and the TBL are significantly different from what were observed in quiescent conditions. In the midspan xy plane (z = 0 mm), the erupted jet body initially follows a wall-normal trajectory accompanied by the formation of a distinctive front vortex ring. After three convective time scales the jet bends to the crossflow, thus limiting the peak penetration depth to approximately 0.58δ99. Comparison of the normalized jet trajectories indicates that the penetration ability of the PSJ is less than steady jets with the same momentum flow velocity. Prior to the jet diminishing, a recirculation region is observed in the leeward side of the jet body, experiencing first an expansion and then a contraction in the area. In the cross-stream yz plane, the signature structure of jets in a crossflow, the counter-rotating vortex pair (CVP), transports high-momentum flow from the outer layer to the near-wall region, leading to a fuller velocity profile and a drop in the boundary layer shape factor (1.3 to 1.2). In contrast to steady jets, the CVP produced by the PSJ exhibits a prominent spatiotemporal behaviour. The residence time of the CVP is estimated as the jet duration time, while the maximum extent of the affected flow in the three coordinate directions (x, y, and z) is approximately 32D, 8.5D, and 10D, respectively. An extremely high level of turbulent kinetic energy production is shown in the jet shear-layer, front vortex ring, and CVP, of which the contribution of the streamwise Reynolds normal stress is dominant. Finally, a conceptual model of the interaction between the PSJ and the TBL is proposed.

  15. 75 FR 77000 - South Coast Conduit/Upper Reach Reliability Project, Santa Barbara County, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... pipeline for improving water supply reliability to Cachuma Project (CP) and State Water Project (SWP... percent of the water supply for communities along the South Coast of Santa Barbara County. Reclamation... demands it is not able to provide the water needed. No redundant supply or pipeline exists to convey CVP...

  16. 75 FR 29719 - Carbazole Violet Pigment 23 From India: Continuation of Countervailing Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ... From India: Continuation of Countervailing Duty Order AGENCY: Import Administration, International... Pigment 23 From India, 69 FR 77995 (December 29, 2004). On November 2, 2009, the Department initiated and the ITC instituted a sunset review of the CVD order on CVP-23 from India pursuant to section 751(c) of...

  17. 77 FR 1463 - Carbazole Violet Pigment 23 From the People's Republic of China: Final Rescission of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... finished pigment in the form of presscake and dry color. Pigment dispersions in any form (e.g., pigments... DEPARTMENT OF COMMERCE International Trade Administration [A-570-892] Carbazole Violet Pigment 23... administrative review of the antidumping duty order on carbazole violet pigment 23 (CVP-23) from the People's...

  18. 76 FR 55003 - Carbazole Violet Pigment 23 From the People's Republic of China: Preliminary Intent To Rescind...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ... finished pigment in the form of presscake and dry color. Pigment dispersions in any form (e.g., pigments... DEPARTMENT OF COMMERCE International Trade Administration [A-570-892] Carbazole Violet Pigment 23... antidumping duty order on carbazole violet pigment 23 (CVP 23) from the People's Republic of China (PRC). This...

  19. Evolutionary drivers of mast-seeding in a long-lived desert shrub

    Treesearch

    Susan E. Meyer; Burton K. Pendleton

    2015-01-01

    Patterns of reproductive output in blackbrush did not track current growing season precipitation, but instead were regulated by prior-year weather cues. The strength of the response to the masting cue depended on habitat quality, with higher mean reproductive output, shorter intervals between years of high seed production, and lower CVp at more favorable sites...

  20. Baroreflex-Mediated Heart Rate and Vascular Resistance Responses 24 h after Maximal Exercise

    DTIC Science & Technology

    2003-01-01

    of normal physiological function in bedridden patients and astronauts. The implication for failure of CVP and plasma volume to return to baseline... FUNCTION , BLOOD PRES- SURE, CENTRAL VENOUS PRESSURE, PHENYLEPHRINE, NECK PRESSURE, LOWER BODY NEGATIVE PRESSURE, COUNTERMEASURES Increased incidence of...orthostatic hypotension and intol-erance in humans is associated with vascular hypovole-mia and attenuated cardiovascular reflex functions

  1. [The Contribution of Vascular Capacity and Blood Volume to Maintain Stable Blood Circulation during General Anesthesia].

    PubMed

    Shigemi, Kenji

    2016-05-01

    To maintain proper cardiac preload is one of the most effective procedures for the systemic circulation remaining stable. In particular, the balance between vascular capacity and total blood volume must be maintained within appropriate range by the administration of fluids, blood and/or vasoactive drugs with mean circulatory filling pressure (Pmcf), central venous pressure (CVP) or stroke volume variation (SVV). End-diastolic left ventricular volume (Ved) is theoretically the best index of cardiac preload; however, without transesophageal echocardbalanceiogram we cannot directly monitor Ved during anesthesia. The infused fluid volume remaining in intravascular space, the vascular capacity controlled by autonomic nervous system and/or vasoactive agents, and the unstressed blood volume properly mobilized to excess blood volume are the crucial factors to maintain cardiac output The knowledge of vascular physiology contribute the decision making to manipulate such factors to control blood circulation during general anesthesia. For example, CVP is usually maintained in the narrow range and seems to be stable; however, it must be changed just after the circulatory disturbances, such as acute bleeding, blood transfusion, and fluid infusion, and followed by gradual returning to initial value, because of the solid mechanism to preserve cardiac output

  2. Altered baroreflex control of forearm vascular resistance during simulated microgravity

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Doerr, D. F.; Vernikos, J.

    1994-01-01

    Reflex peripheral vasoconstriction induced by activation of cardiopulmonary baroreceptors in response to reduced central venous pressure (CVP) is a basic mechanism for elevating systemic vascular resistance and defending arterial blood pressure during orthostatically-induced reductions in cardiac filling and output. The sensitivity of the cardiopulmonary baroreflex response [defined as the slope of the relationship between changes in forearm vascular resistance (FVR) and CVP] and the resultant vasoconstriction are closely and inversely associated with the amount of circulating blood volume. Thus, a high-gain FVR response will be elicited by a hypovolemic state. Exposure to microgravity during spaceflight results in reduced plasma volume. It is therefore reasonable to expect that the FVR response to cardiopulmonary baroreceptor unloading would be accentuated following adaptation to microgravity. Such data could provide better insight about the physiological mechanisms underlying alterations in blood pressure control following spaceflight. We therefore exposed eleven men to 6 degrees head-down bedrest for 7 days and measured specific hemodynamic responses to low levels of the lower body negative pressure to determine if there are alterations in cardiopulmonary baroreceptor stimulus-FVR reflex response relationship during prolonged exposure to an analog of microgravity.

  3. Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

  4. Cost-volume-profit analysis and expected benefit of health services: a study of cardiac catheterization services.

    PubMed

    Younis, Mustafa Z; Jabr, Samer; Smith, Pamela C; Al-Hajeri, Maha; Hartmann, Michael

    2011-01-01

    Academic research investigating health care costs in the Palestinian region is limited. Therefore, this study examines the costs of the cardiac catheterization unit of one of the largest hospitals in Palestine. We focus on costs of a cardiac catheterization unit and the increasing number of deaths over the past decade in the region due to cardiovascular diseases (CVDs). We employ cost-volume-profit (CVP) analysis to determine the unit's break-even point (BEP), and investigate expected benefits (EBs) of Palestinian government subsidies to the unit. Findings indicate variable costs represent 56 percent of the hospital's total costs. Based on the three functions of the cardiac catheterization unit, results also indicate that the number of patients receiving services exceed the break-even point in each function, despite the unit receiving a government subsidy. Our findings, although based on one hospital, will permit hospital management to realize the importance of unit costs in order to make informed financial decisions. The use of break-even analysis will allow area managers to plan minimum production capacity for the organization. The economic benefits for patients and the government from the unit may encourage government officials to focus efforts on increasing future subsidies to the hospital.

  5. Closed-Loop Control of Fluid Therapy for Treatment of Hypovolemia

    DTIC Science & Technology

    2008-04-01

    index) (Table 2). Invasive bladder catheterization and blood sampling add the use of urinary output, lactate, central venous oxygen saturation, he...for guiding burn resuscitation Time delay, renal failure, and drugs complicate interpretation Central venous oxygenation ScvO2 Global perfusion index... Central venous pressure (CVP) Sensitive to volume change Pre-injury baseline values vary Arterial pressure by transducer Real-time continuous

  6. Oral and vocal fold diadochokinesis in dysphonic women

    PubMed Central

    LOUZADA, Talita; BERALDINELLE, Roberta; BERRETIN-FELIX, Giédre; BRASOLOTTO, Alcione Ghedini

    2011-01-01

    The evaluation of oral and vocal fold diadochokinesis (DDK) in individuals with voice disorders may contribute to the understanding of factors that affect the balanced vocal production. Scientific studies that make use of this assessment tool support the knowledge advance of this area, reflecting the development of more appropriate therapeutic planning. Objective To compare the results of oral and vocal fold DDK in dysphonic women and in women without vocal disorders. Material and methods For this study, 28 voice recordings of women from 19 to 54 years old, diagnosed with dysphonia and submitted to a voice assessment from speech pathologist and otorhinolaryngologist, were used. The control group included 30 nondysphonic women evaluated in prior research from normal adults. The analysis parameters like number and duration of emissions, as well as the regularity of the repetition of syllables "pa", "ta", "ka" and the vowels "a" and "i," were provided by the Advanced Motor Speech Profile program (MSP) Model-5141, version-2.5.2 (KayPentax). The DDK sequence "pataka" was analyzed quantitatively through the Sound Forge 7.0 program, as well as manually with the audio-visual help of sound waves. Average values of oral and vocal fold DDK dysphonic and nondysphonic women were compared using the "t Student" test and were considered significant when p<0.05. Results The findings showed no significant differences between populations; however, the coefficient of variation of period (CvP) and jitter of period (JittP) average of the "ka," "a" and "i" emissions, respectively, were higher in dysphonic women (CvP=10.42%, 12.79%, 12.05%; JittP=2.05%, 6.05%, 3.63%) compared to the control group (CvP=8.86%; 10.95%, 11.20%; JittP=1.82%, 2.98%, 3.15%). Conclusion Although the results do not indicate any difficulties in oral and laryngeal motor control in the dysphonic group, the largest instability in vocal fold DDK in the experimental group should be considered, and studies of this ability in individuals with communication disorders must be intensified. PMID:22230989

  7. Discharge rate measurements in a canal using radiotracer methods.

    PubMed

    Pant, H J; Goswami, Sunil; Biswal, Jayashree; Samantray, J S; Sharma, V K

    2016-06-01

    Discharge rates of water were measured in a canal using radiotracer methods with an objective to validate the efficacy of Concrete Volute Pumps (CVPs) installed at various pumping stations along the canal. Pulse velocity and dilution methods were applied to measure the discharge rates using Iodine-131 as a radiotracer. The discharge rate measured in one of the sections of the canal using the pulse velocity method was found to be 22.5m(3)/s, whereas the discharge rates measured using the dilution method in four different sections of the canal varied from 20.27 to 20.62m(3)/s with single CVP in operation. The standard error in discharge rate measurements using dilution method ranged from ±1.1 to ±1.8%. The experimentally measured values of the discharge rate were in good agreement with the design value of the discharge rate (20m(3)/s) thus validating the performance of the CVPs used in the canal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Phases-of-illness paradigm: better communication, better outcomes

    DTIC Science & Technology

    2011-11-28

    ILP) 2. Hold continuous sedation at 0600 ( nurse ) 3. Notify RT when the patient is ‘awake’ ( nurse ) 4. Perform breathing trial (RT) CVP, central...recovery phases. Patients transitioned to palliative care would exit this model into a palliative care ‘phase’ that is distinct because it is blind...patient-driven standardization of supportive care elements, such as types of monitoring, frequency and type of laboratory assessment, sedation

  9. Effect of Inhalation of Lavender Essential Oil on Vital Signs in Open Heart Surgery ICU.

    PubMed

    Salamati, Armaiti; Mashouf, Soheyla; Mojab, Faraz

    2017-01-01

    This study evaluated the effects of inhalation of Lavender essential oil on vital signs in open heart surgery ICU. The main complaint of patients after open-heart surgery is dysrhythmia, tachycardia, and hypertension due to stress and pain. Due to the side effects of chemical drugs, such as opioids, use of non-invasive methods such as aromatherapy for relieving stress and pain parallel to chemical agents could be an important way to decrease the dose and side effects of analgesics. In a multicenter, single-blind trial, 40 patients who had open-heart surgery were recruited. Inclusion criteria were full consciousness, lack of hemorrhage, heart rate >60 beats/min, systolic blood pressure > 100 mmHg, and diastolic blood pressure > 60 mmHg, not using beta blockers in the operating room or ICU, no history of addiction to opioids or use of analgesics in regular, spontaneous breathing ability and not receiving synthetic opioids within 2 h before extubation. Ten minutes after extubation, the patients› vital signs [including BP, HR, Central Venous Pressure (CVP), SPO2, and RR] were measured. Then, a cotton swab, which was impregnated with 2 drops of Lavender essential oil 2%, was placed in patients' oxygen mask and patients breathed for 10 min. Thirty minutes after aromatherapy, the vital signs were measured again. Main objective of this study was the change in vital sign before and after aromatherapy. Statistical significance was accepted for P < 0.05. There was a significant difference in systolic blood pressure (p > 0.001), diastolic blood pressure (p = 0.001), and heart rate (p = 0.03) before and after the intervention using paired t-test. Although, the results did not show any significant difference in respiratory rate (p = 0.1), SpO2 (p = 0.5) and CVP (p = 0.2) before and after inhaling Lavender essential oil. Therefore, the aromatherapy could effectively reduce blood pressure and heart rate in patients admitted to the open heart surgery ICU and can be used as an independent nursing intervention in stabilizing mentioned vital signs. The limitations of our study were sample size and lack of control group. Randomized clinical trials with larger sample size are recommended.

  10. Leaf hydraulic conductance varies with vein anatomy across Arabidopsis thaliana wild-type and leaf vein mutants.

    PubMed

    Caringella, Marissa A; Bongers, Franca J; Sack, Lawren

    2015-12-01

    Leaf venation is diverse across plant species and has practical applications from paleobotany to modern agriculture. However, the impact of vein traits on plant performance has not yet been tested in a model system such as Arabidopsis thaliana. Previous studies analysed cotyledons of A. thaliana vein mutants and identified visible differences in their vein systems from the wild type (WT). We measured leaf hydraulic conductance (Kleaf ), vein traits, and xylem and mesophyll anatomy for A. thaliana WT (Col-0) and four vein mutants (dot3-111 and dot3-134, and cvp1-3 and cvp2-1). Mutant true leaves did not possess the qualitative venation anomalies previously shown in the cotyledons, but varied quantitatively in vein traits and leaf anatomy across genotypes. The WT had significantly higher mean Kleaf . Across all genotypes, there was a strong correlation of Kleaf with traits related to hydraulic conductance across the bundle sheath, as influenced by the number and radial diameter of bundle sheath cells and vein length per area. These findings support the hypothesis that vein traits influence Kleaf , indicating the usefulness of this mutant system for testing theory that was primarily established comparatively across species, and supports a strong role for the bundle sheath in influencing Kleaf . © 2015 John Wiley & Sons Ltd.

  11. The oral lipid sensor GPR120 is not indispensable for the orosensory detection of dietary lipids in mice

    PubMed Central

    Ancel, Déborah; Bernard, Arnaud; Subramaniam, Selvakumar; Hirasawa, Akira; Tsujimoto, Gozoh; Hashimoto, Toshihiro; Passilly-Degrace, Patricia; Khan, Naim-Akhtar; Besnard, Philippe

    2015-01-01

    Implication of the long-chain fatty acid (LCFA) receptor GPR120, also termed free fatty acid receptor 4, in the taste-guided preference for lipids is a matter of debate. To further unravel the role of GPR120 in the “taste of fat”, the present study was conducted on GPR120-null mice and their wild-type littermates. Using a combination of morphological [i.e., immunohistochemical staining of circumvallate papillae (CVP)], behavioral (i.e., two-bottle preference tests, licking tests and conditioned taste aversion) and functional studies [i.e., calcium imaging in freshly isolated taste bud cells (TBCs)], we show that absence of GPR120 in the oral cavity was not associated with changes in i) gross anatomy of CVP, ii) LCFA-mediated increases in intracellular calcium levels ([Ca2+]i), iii) preference for oily and LCFA solutions and iv) conditioned avoidance of LCFA solutions. In contrast, the rise in [Ca2+]i triggered by grifolic acid, a specific GPR120 agonist, was dramatically curtailed when the GPR120 gene was lacking. Taken together, these data demonstrate that activation of lingual GPR120 and preference for fat are not connected, suggesting that GPR120 expressed in TBCs is not absolutely required for oral fat detection in mice PMID:25489006

  12. Quaternary bimodal volcanism in the Niğde Volcanic Complex (Cappadocia, central Anatolia, Turkey): age, petrogenesis and geodynamic implications

    NASA Astrophysics Data System (ADS)

    Aydin, Faruk; Schmitt, Axel K.; Siebel, Wolfgang; Sönmez, Mustafa; Ersoy, Yalçın; Lermi, Abdurrahman; Dirik, Kadir; Duncan, Robert

    2014-11-01

    The late Neogene to Quaternary Cappadocian Volcanic Province (CVP) in central Anatolia is one of the most impressive volcanic fields of Turkey because of its extent and spectacular erosionally sculptured landscape. The late Neogene evolution of the CVP started with the eruption of extensive andesitic-dacitic lavas and ignimbrites with minor basaltic lavas. This stage was followed by Quaternary bimodal volcanism. Here, we present geochemical, isotopic (Sr-Nd-Pb and δ18O isotopes) and geochronological (U-Pb zircon and Ar-Ar amphibole and whole-rock ages) data for bimodal volcanic rocks of the Niğde Volcanic Complex (NVC) in the western part of the CVP to determine mantle melting dynamics and magmatic processes within the overlying continental crust during the Quaternary. Geochronological data suggest that the bimodal volcanic activity in the study area occurred between ca. 1.1 and ca. 0.2 Ma (Pleistocene) and comprises (1) mafic lavas consisting of basalts, trachybasalts, basaltic andesites and scoria lapilli fallout deposits with mainly basaltic composition, (2) felsic lavas consisting of mostly rhyolites and pumice lapilli fall-out and surge deposits with dacitic to rhyolitic composition. The most mafic sample is basalt from a monogenetic cone, which is characterized by 87Sr/86Sr = 0.7038, 143Nd/144Nd = 0.5128, 206Pb/204Pb = 18.80, 207Pb/204Pb = 15.60 and 208Pb/204Pb = 38.68, suggesting a moderately depleted signature of the mantle source. Felsic volcanic rocks define a narrow range of 143Nd/144Nd isotope ratios (0.5126-0.5128) and are homogeneous in Pb isotope composition (206Pb/204Pb = 18.84-18.87, 207Pb/204Pb = 15.64-15.67 and 208Pb/204Pb = 38.93-38.99). 87Sr/86Sr isotopic compositions of mafic (0.7038-0.7053) and felsic (0.7040-0.7052) samples are similar, reflecting a common mantle source. The felsic rocks have relatively low zircon δ18O values (5.6 ± 0.6 ‰) overlapping mantle values (5.3 ± 0.3 %), consistent with an origin by fractional crystallization from a mafic melt with very minor continental crustal contamination. The geochronological and geochemical data suggest that mafic and felsic volcanic rocks of the NVC are genetically closely related to each other. Mafic rocks show a positive trend between 87Sr/86Sr and Th, suggesting simultaneous assimilation and fractional crystallization, whereas the felsic rocks are characterized by a flat or slightly negative variation. High 87Sr/86Sr gneisses are a potential crustal contaminant of the mafic magmas, but the comparatively low and invariant 87Sr/86Sr in the felsic volcanics suggests that these evolved dominantly by fractional crystallization. Mantle-derived basaltic melts, which experienced low degree of crustal assimilation, are proposed to be the parent melt of the felsic volcanics. Geochronological and geochemical results combined with regional geological and geophysical data suggest that bimodal volcanism of the NVC and the CVP, in general, developed in a post-collisional extensional tectonic regime that is caused by ascending asthenosphere, which played a key role during magma genesis.

  13. The Toxicity of Inhaled Sulphur Mustard

    DTIC Science & Technology

    2012-03-01

    Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and venous ) pH pO2 pCO2 Sodium Potassium Calcium...Cardiovascular Parameters − CFI – Cardiac Function Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure...Data are expressed as mean ± SEM. Changes in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are

  14. West Europe Report

    DTIC Science & Technology

    1987-01-21

    BELGIUM Gol Criticizes CVP on Regional Financing Issues ( Jean Gol Interview; LE SOIR, 14 Nov 86) 52 FINLAND SPAIN Nordic Economic Unity Needs...FLNKS PLANS Paris ROUGE in French 27 Nov-3 Dec 86 p 15 [Interview with FLNKS President Jean -Marie Tjibaou by Alain Krivine in France; date not...given] [Text] Jean -Marie Tjibaou has just paid a visit to France. Chirac, noting his mistrust of the Kanaks, refused to see him. The president of the

  15. Effects of four different positive airway pressures on right internal jugular vein catheterisation.

    PubMed

    Zhou, Qinghe; Xiao, Wangpin; An, Erdan; Zhou, Hongmei; Yan, Min

    2012-05-01

    The right internal jugular vein (RIJV) is often used for central venous catheterisation in patients undergoing major surgery. The efficacy of this route correlates with the diameter of the vein which can be influenced by airway pressure. To investigate four positive airway pressures (PAPs) in mechanically ventilated patients and to determine the most suitable of these for RIJV catheterisation. Prospective, randomised, controlled study. Two Chinese medical centres. Two hundred and forty patients scheduled for gastrointestinal tract surgery under general anaesthesia (male-to-female ratio, 135 : 105; American Society of Anesthesiologists' physical status class, I-III; age range, 19-81 years); patients were excluded from the study if they had a history of haematological disease, external neck injury, RIJV catheterisation, severe cardiovascular disease, RIJV thrombosis, injection-site infection, pneumothorax and pulmonary bulla. They were randomised into four groups of 60, each to undergo RIJV catheterisation at a PAP of 0 (1 cmH2O = 0.098 kPa, group A); 15 (group B); 20 (group C); and 25 cmH2O (group D). Primary outcomes were central venous pressure (CVP) and RIJV cross-sectional area which were measured before and during PAP; the number of catheterisations completed in 30 s; the number of first pass punctures; heart rate and mean arterial pressure which were monitored continuously; and the incidence of complications which included local haematoma, pneumothorax and internal carotid artery (ICA) puncture. Two patients were excluded following ICA puncture, leaving 238 for analysis. In groups C and D, the CVP and the cross-sectional area of RIJV were significantly larger; the number completing catheterisation within 30 s and the number of first pass punctures increased significantly and was comparable between these two groups. Compared with groups A and B, the incidences of hypotension and bradycardia were significantly increased in groups C and D. The incidence of local haematoma was significantly increased in group D compared with other groups. RIJV catheterisation was completed successfully in all but two patients in group A. A PAP of 20 cmH2O seems most suitable for successful RIJV catheterisation in mechanically ventilated patients. It is associated with an increase in cross-sectional RIJV area and CVP, which facilitate cannulation, and results in fewer puncture-related complications. However, meticulous haemodynamic monitoring is needed to avoid hypotension and bradycardia.

  16. Structure in the Near Field of the Transverse Jet

    DTIC Science & Technology

    1990-04-13

    73 7.1.2 Rate of strain vs. vorticity ...... .................. 74 7.1.3 Total pressure gradients ...... .................... 75 7.1.4...vorticity from within the nozzle evolves into the CVP vorticity. 7.1.2 Rate of strain vs. vorticity Although there is no mechanism in the present flow...by which to generate new vor- ticity within the flow, such is not the case for the rate of strain (Morton 1984). The 2-D equation governing the rate

  17. The Toxicity of Inhaled Sulphur Mustard

    DTIC Science & Technology

    2012-10-01

    Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure − DO2 – Oxygen Delivery − dpMax – Maximum...in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are expressed as mean ± SEM. UK UNCLASSIFIED Page 64 of...Respiratory rate (RR) Heart rate (HR) Expired CO2 Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and

  18. Evaluation of prenatal risk factors for prediction of outcome in right heart lesions: CVP score in fetal right heart defects.

    PubMed

    Neves, Ana Luisa; Mathias, Leigh; Wilhm, Marilyn; Leshko, Jennifer; Linask, Kersti K; Henriques-Coelho, Tiago; Areias, José C; Huhta, James C

    2014-09-01

    To determine the prenatal variables predicting the risk of perinatal death in congenital right heart defects. Retrospective analysis of 28 fetuses with right heart defects was performed. Logistic regression analyses were performed to obtain odds ratios (OR) for the relationship between the risk of death and echocardiographic parameters. The parameters that correlated with the outcome were incorporated in an attempt to devise a disease-specific cardiovascular profile score. Fetal echocardiograms (143) from 28 patients were analyzed. The cardiovascular profile score predicted the risk of death. A lower right ventricle (RV) pressure was associated with mortality (OR 0.959; 95% confidence intervals (CI) 0.940-0.978). Higher peak aortic velocity through the aortic valve (OR 0.104; 95% CI 0.020-0.529) was associated with a better outcome. These cardiac function parameters were incorporated in a modified disease-specific CVP Score. Patients with a mean modified cardiovascular profile score of ≤ 6 were over 3.7 times more likely to die than those with scores of 7-10. The original Cardiovascular Profile Score predicted the risk of death in right heart defects. The modified score was not validated as a good prediction tool by this study. Fetal RV pressure estimate and peak aortic velocity can be used as independent prognostic predictors.

  19. Cardiopulmonary function and oxygen delivery during total liquid ventilation.

    PubMed

    Tsagogiorgas, Charalambos; Alb, Markus; Herrmann, Peter; Quintel, Michael; Meinhardt, Juergen P

    2011-10-01

    Total liquid ventilation (TLV) with perfluorocarbons has shown to improve cardiopulmonary function in the injured and immature lung; however there remains controversy over the normal lung. Hemodynamic effects of TLV in the normal lung currently remain undetermined. This study compared changes in cardiopulmonary and circulatory function caused by either liquid or gas tidal volume ventilation. In a prospective, controlled study, 12 non-injured anesthetized, adult New Zealand rabbits were primarily conventionally gas-ventilated (CGV). After instrumentation for continuous recording of arterial (AP), central venous (CVP), left artrial (LAP), pulmonary arterial pressures (PAP), and cardiac output (CO) animals were randomized into (1) CGV group and (2) TLV group. In the TLV group partial liquid ventilation was initiated with instillation of perfluoroctylbromide (12 ml/kg). After 15 min, TLV was established for 3 hr applying a volume-controlled, pressure-limited, time-cycled ventilation mode using a double-piston configured TLV. Controls (CGV) remained gas-ventilated throughout the experiment. During TLV, heart rate, CO, PAP, MAP, CVP, and LAP as well as derived hemodynamic variables, arterial and mixed venous blood gases, oxygen delivery, PVR, and SVR did not differ significantly compared to CGV. Liquid tidal volumes suitable for long-term TLV in non-injured rabbits do not significantly impair CO, blood pressure, and oxygen dynamics when compared to CGV. Copyright © 2011 Wiley-Liss, Inc.

  20. The oral lipid sensor GPR120 is not indispensable for the orosensory detection of dietary lipids in mice.

    PubMed

    Ancel, Déborah; Bernard, Arnaud; Subramaniam, Selvakumar; Hirasawa, Akira; Tsujimoto, Gozoh; Hashimoto, Toshihiro; Passilly-Degrace, Patricia; Khan, Naim-Akhtar; Besnard, Philippe

    2015-02-01

    Implication of the long-chain fatty acid (LCFA) receptor GPR120, also termed free fatty acid receptor 4, in the taste-guided preference for lipids is a matter of debate. To further unravel the role of GPR120 in the "taste of fat", the present study was conducted on GPR120-null mice and their wild-type littermates. Using a combination of morphological [i.e., immunohistochemical staining of circumvallate papillae (CVP)], behavioral (i.e., two-bottle preference tests, licking tests and conditioned taste aversion) and functional studies [i.e., calcium imaging in freshly isolated taste bud cells (TBCs)], we show that absence of GPR120 in the oral cavity was not associated with changes in i) gross anatomy of CVP, ii) LCFA-mediated increases in intracellular calcium levels ([Ca(2+)]i), iii) preference for oily and LCFA solutions and iv) conditioned avoidance of LCFA solutions. In contrast, the rise in [Ca(2+)]i triggered by grifolic acid, a specific GPR120 agonist, was dramatically curtailed when the GPR120 gene was lacking. Taken together, these data demonstrate that activation of lingual GPR120 and preference for fat are not connected, suggesting that GPR120 expressed in TBCs is not absolutely required for oral fat detection in mice. Copyright © 2015 by the American Society for Biochemistry and Molecular Biology, Inc.

  1. [Treatment of acute respiratory distress syndrome using pressure and volume controlled ventilation with lung protective strategy].

    PubMed

    Ge, Ying; Wan, Yong; Wang, Da-qing; Su, Xiao-lin; Li, Jun-ying; Chen, Jing

    2004-07-01

    To investigate the significance and effect of pressure controlled ventilation (PCV) as well as volume controlled ventilation (VCV) by lung protective strategy on respiratory mechanics, blood gas analysis and hemodynamics in patients with acute respiratory distress syndrome (ARDS). Fifty patients with ARDS were randomly divided into PCV and VCV groups with permissive hypercapnia and open lung strategy. Changes in respiratory mechanics, blood gas analysis and hemodynamics were compared between two groups. Peak inspiration pressure (PIP) in PCV group was significantly lower than that in VCV group, while mean pressure of airway (MPaw) was significantly higher than that in VCV after 24 hours mechanical ventilation. After 24 hours mechanical ventilation, there were higher central venous pressure (CVP) and slower heart rate (HR) in two groups, CVP was significantly higher in VCV compared with PCV, and PCV group had slower HR than VCV group, the two groups had no differences in mean blood pressure (MBP) at various intervals. All patients showed no ventilator-induced lung injury. Arterial blood oxygenations were obviously improved in two groups after 24 hours mechanical ventilation, PCV group had better partial pressure of oxygen in artery (PaO2) than VCV group. Both PCV and VCV can improve arterial blood oxygenations, prevent ventilator-induced lung injury, and have less disturbance in hemodynamic parameters. PCV with lung protective ventilatory strategy should be early use for patients with ARDS.

  2. Atrial stretch delays gastric emptying of liquids in awake rats.

    PubMed

    Palheta, R C; Silva, M T B; Barbosa, H L G; Pinheiro, A D N; Cardoso, K V V; Graça, J R V; Magalhães, P J C; Oliveira, R B; Santos, A A

    2013-03-21

    We previously reported that mechanical atrial stretch (AS) by balloon distention increased gastric tonus in anesthetized rats. The present study evaluated the effect of AS on the gastric emptying of a liquid test meal in awake rats and its underlying neural mechanisms. Anesthetized male rats received a balloon catheter into the right atrium and a gastrostomy cannula. The next day, mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP), and cardiac output (CO) were continuously monitored. After the first 20min of monitoring (basal interval), the balloon was either distended or not (control) with 30, 50, or 70μl saline for 5min. Fifteen minutes later, the rats received the test meal (glucose solution with phenol red), and fractional gastric dye retention was determined 10, 20, or 30min later. Heart rate and CVP values were transiently increased by 50 or 70μl AS but not 30μl AS, whereas gastric emptying was slower after 30, 50, or 70μl AS than after sham distention. Subdiaphragmatic vagotomy or splanchnicotomy+celiac ganglionectomy and capsaicin, ondansetron, hexamethonium, L-NAME, and glibenclamide treatment prevented the AS-induced delay in gastric emptying, whereas atropine and guanethidine treatment failed to prevent it. Atrial stretch inhibited the gastric emptying of liquid via non-adrenergic and non-cholinergic pathways that activate nitric oxide-K(+)ATP channels. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Comparative characterization of physicochemical properties and bioactivities of polysaccharides from selected medicinal mushrooms.

    PubMed

    Su, Chun-Han; Lai, Min-Nan; Lin, Ching-Chuan; Ng, Lean-Teik

    2016-05-01

    Mushroom polysaccharides have been known to possess various pharmacological activities. However, information on their chemical and biological differences between mushrooms remains limited. In this study, we aimed to examine the differences in physicochemical characteristics of polysaccharides prepared from Antrodia cinnamomea (AC-P), Coriolus versicolor (CV-P), Grifola frondosa (GF-P), Ganoderma lucidum (GL-P), and Phellinus linteus (PL-P), followed by evaluating their inhibitory effects on nitric oxide (NO) production in lipopolysaccharide (LPS)-stimulated RAW264.7 macrophages. Results showed that under similar conditions of preparation, the monosaccharide composition of polysaccharides varied between different mushrooms, and glucose was the predominant monosaccharide, followed by galactose and mannose. AC-P and GF-P contained the highest amount of (1,3;1,6)-β-D-glucans. The degree of branching of (1,3;1,6)-β-D-glucans in all polysaccharides ranged from 0.21 to 0.26, with the exception of GF-P (0.38). The molecular weights of different polysaccharides showed diverse distributions; AC-P, CV-P, and GF-P contained two major macromolecular populations (< 30 and >200 kDa) and possessed triple-helix conformation, whereas GL-P (10.2 kDa) and PL-P (15.5 kDa) only had a low molecular weight population without triple-helix structure. These polysaccharides showed different inhibitory potency on NO production in LPS-stimulated RAW264.7 cells.

  4. Yeast mixture of liquid beer and cassava pulp with rice straw for the growth of dairy heifers.

    PubMed

    Kamphayae, Sukanya; Kumagai, Hajime; Butcha, Patima; Ritruechai, Viroj; Udchachon, Supachai

    2017-03-01

    This study was conducted to determine the effects of mixtures of liquid brewer's yeast (LBY) and cassava pulp (CVP) with rice straw (RS) on feed intake, digestibility, rumen fermentation, and growth of dairy heifers. Sixteen Holstein crossbred heifers (13.8 ± 1.6 months old, 210 ± 23 kg body weight (BW)) were randomly allocated to four feeding treatments with four replications, which were 0:0:100 (RS), 0:70:30 (0%LBY), 20:50:30 (20%LBY), and 50:20:30 (50%LBY), respectively, for LBY/CVP/RS on a fresh matter basis. The heifers were offered conventional concentrate at 1.5% initial body weight daily and fed the treatment diets ad libitum. Average daily gain and feed intake were not significantly different among the treatments. The heifers fed 50%LBY had the highest crude protein (CP) intake and DM, OM, and CP digestibility (P < 0.05). The ruminal pH did not differ significantly among treatments, while NH 3 -N was the highest (P < 0.05) in 50%LBY. Total volatile fatty acid (VFA) concentrations and the molar proportion of each VFA were not significantly different among the treatments. Blood urea nitrogen concentrations of 50%LBY were the highest among the treatments (P < 0.05). The results indicated that 50%LBY improved CP digestibility.

  5. Effects of Simulated Pathophysiology on the Performance of a Decision Support Medical Monitoring System for Early Detection of Hemodynamic Decompensation in Humans

    DTIC Science & Technology

    2014-10-01

    pulse oximeter (Cardiocap/5; Datex-Ohmeda, Louisville, CO). The EKG and pulse oximeter tracings were interfaced with a personal computer for con- tinuous...responses to reduced central venous pressure (CVP) and pulse pressure (PP) elicited during graded lower body negative pressure (LBNP) to those observed...Johnson BD, Curry TB, Convertino VA, & Joyner MJ. The association between pulse pressure and stroke volume during lower body negative pressure and

  6. [Effect of hydroxyethyl starch 130/0.4 on S100B protein level and cerebral oxygen metabolism in open cardiac surgery under cardiopulmonary bypass].

    PubMed

    Pi, Zhi-bing; Tan, Guan-xian; Wang, Jun-lu

    2007-07-17

    To observe the effect of hydroxyethyl starch (HES) 130/0.4 on S100B protein level and cerebral metabolism of oxygen in open cardiac surgery under cardiopulmonary bypass (CPB) and to explore whether it has the protective effect of 6%HES130/0.4 as priming solution on cerebral injury during CPB and explore the probable mechanism. Forty patients with atrioseptal defect or ventricular septal defect scheduled for elective surgical repair under CPB with moderate hypothermia were randomly divided into two equal groups: HES 130/0.4 group (HES group) in which HES 130/0.4 (voluven) was used as priming solution and gelatin group (GRL group) in which gelofusine (succinylated gelatin) was used as priming solution. ECG, heart rate (HR), blood pressure (BP), mean arterial pressure (MAP), central venous pressure (CVP), arterial partial pressure of oxygen (P(a)O(2),), arterial partial pressure of carbon dioxide (P(et)CO(2)) and body temperature (naso-pharyngeal and rectal) were continuously monitored during the operation. Blood samples were obtained from the central vein for determination of blood concentrations of S100B protein at the following time points: before CPB (T(0)), 20 minutes after the beginning of CPB (T(1)), immediately after the termination of CPB (T(2)), 60 minutes after the termination of CPB (T(3)), and 24 hours after the termination of CPB (T(4)). The serum S100B protein levels were measured by ELISA. At the same time points blood samples were obtained from the jugular vein and radial artery to undergo blood gas analysis and measurement of blood glucose, based on which the cerebral oxygen metabolic rate/cerebral metabolic rate of glucose (CMRO(2)/CMR(GLU)) was calculated. Compared with the time point of immediately before CPB (T(0)), The S100B protein level of the 2 groups began to increase since the time point T(1), peaked at the time point T(2), began to decrease gradually since the time point T(3), and were still significantly higher than those before CPB at the time point T(4) (all P < 0.01), and the S100B protein levels at different time points of the HES group were all significantly lower than those of the GEL group (all P < 0.01). The S(jv)O(2) and CMRO(2)/CMR(GLU) levels of both groups increased at the time point T(1), decreased at the time points T(2) and T(3), and then restored to normal at the time points T(4). In the GEL group there were no significant differences in the levels between any 2 different time points, however, in the HES group S(jv)O(2) and CMRO(2)/CMR(GLU) levels at T(1) was significantly higher than those at the other time points (P < 0.05 or P < 0.01). S100B protein increases significantly in open cardiac surgery under CPB. HES130/0.4 lowers the S100B protein levels from the beginning of CPB to one hour after the termination of CPB with the probable mechanism of improving the cerebral metabolism of oxygen. 6%HES130/0.4 as priming solution may play a protective role in reduction of cerebral injury during CPB and open cardiac surgery.

  7. Latest developments in peri-operative monitoring of the high-risk major surgery patient.

    PubMed

    Green, David; Paklet, Lise

    2010-01-01

    Peri-operative monitoring technology has made great strides in the last 20 years with the introduction of minimally invasive devices to measure inter alia stroke volume, cardiac output, depth of anaesthesia and cerebral and tissue oxygen monitoring. Despite these technological advances, peri-operative management of the high risk major surgery patient has remained virtually unchanged. The vast majority of patients undergo a pre-operative assessment which is neither designed to quantify functional capacity nor predict outcome. Anaesthetists then usually monitor these patients using the same technology (e.g. pulse oximetry (SpO2), invasive systemic BP and CVP, end tidal carbon dioxide (etCO2) and anaesthetic agent monitoring) that was available in the early 1980s. Conventional intra-operative management can result in occult low levels of blood flow and oxygen delivery that lead to complications that only occur days or weeks following surgery and give false re-assurance to the anaesthetist that he or she is doing a "good job". Post-operative management then often takes place in an environment with reduced levels of both monitoring equipment and staff expertise. It is perhaps not surprising that outcome still remains poor in high-risk patients.(1) In this review, we will briefly describe the role of peri-operative optimization, some of the available monitors and indicate how their combined use might be beneficial in managing the high-risk surgical patient. We believe that although there is now evidence to suggest that the use of individual new monitors (such as assessment of fluid status, depth of anaesthesia, tissue oxygenation and blood flow) can influence outcome, it will only be their combination that will radically improve the peri-operative management and outcome of high-risk surgical patients. It is a matter of some urgency that large scale, prospective and collaborative studies be designed, funded and executed to prove or disprove this hypothesis. Copyright 2009 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  8. Effect of Inhalation of Lavender Essential Oil on Vital Signs in Open Heart Surgery ICU

    PubMed Central

    Salamati, Armaiti; Mashouf, Soheyla; Mojab, Faraz

    2017-01-01

    This study evaluated the effects of inhalation of Lavender essential oil on vital signs in open heart surgery ICU. The main complaint of patients after open-heart surgery is dysrhythmia, tachycardia, and hypertension due to stress and pain. Due to the side effects of chemical drugs, such as opioids, use of non-invasive methods such as aromatherapy for relieving stress and pain parallel to chemical agents could be an important way to decrease the dose and side effects of analgesics. In a multicenter, single-blind trial, 40 patients who had open-heart surgery were recruited. Inclusion criteria were full consciousness, lack of hemorrhage, heart rate >60 beats/min, systolic blood pressure > 100 mmHg, and diastolic blood pressure > 60 mmHg, not using beta blockers in the operating room or ICU, no history of addiction to opioids or use of analgesics in regular, spontaneous breathing ability and not receiving synthetic opioids within 2 h before extubation. Ten minutes after extubation, the patients› vital signs [including BP, HR, Central Venous Pressure (CVP), SPO2, and RR] were measured. Then, a cotton swab, which was impregnated with 2 drops of Lavender essential oil 2%, was placed in patients’ oxygen mask and patients breathed for 10 min. Thirty minutes after aromatherapy, the vital signs were measured again. Main objective of this study was the change in vital sign before and after aromatherapy. Statistical significance was accepted for P < 0.05. There was a significant difference in systolic blood pressure (p > 0.001), diastolic blood pressure (p = 0.001), and heart rate (p = 0.03) before and after the intervention using paired t-test. Although, the results did not show any significant difference in respiratory rate (p = 0.1), SpO2 (p = 0.5) and CVP (p = 0.2) before and after inhaling Lavender essential oil. Therefore, the aromatherapy could effectively reduce blood pressure and heart rate in patients admitted to the open heart surgery ICU and can be used as an independent nursing intervention in stabilizing mentioned vital signs. The limitations of our study were sample size and lack of control group. Randomized clinical trials with larger sample size are recommended. PMID:28496494

  9. [Gastric mucosa tonometry in routine monitoring in the surgical intensive care unit].

    PubMed

    Pestel, G; Uhlig, T; Götschl, A; Schmucker, P; Rothhammer, A

    1998-06-01

    Monitoring tissue oxygenation in the splanchnic region could be helpful for critically ill patients. In this study the postoperative course of gastric mucosal CO2 (prCO2) in 40 patients is shown. Following approval of the ethics committee, 24 patients schedulded for surgery with an expected large fluid turnover and 16 multiple injured patients were monitored with a gas tonometry device in addition to standard monitoring (ECG, pulse oximetry, capnometry, CVP, arterial pressure). Normoventilated patients with prCO2 > 50 for more than 30 minutes were treated with fluid therapy, followed by catecholamine therapy, followed by transfusion (fig. 1). All patients were admitted to the SICU post-operatively. The variation of prCO2-values was greater in multiple injured patients. Their prCO2-values began in a lower range compared to patients with scheduled operation, became higher at the end of the first SICU-day and remained higher thereafter. They had a higher fluid turnover and needed more catecholamines. Multiple injured patients with an arterio-intestinal CO2-Difference (CO2-Gap) > 10 had a higher ISS-Score, were longer mechanically ventilated, had a longer SICU-stay and a higher incidence of complications in comparison to patients with aCO2-Gap < 10. Perhaps a CO2-Gap > 10 could be predictive for a more severe course in intensive care patients.

  10. Age, splanchnic vasoconstriction, and heat stress during tilting

    NASA Technical Reports Server (NTRS)

    Minson, C. T.; Wladkowski, S. L.; Pawelczyk, J. A.; Kenney, W. L.

    1999-01-01

    During upright tilting, blood is translocated to the dependent veins of the legs and compensatory circulatory adjustments are necessary to maintain arterial pressure. For examination of the effect of age on these responses, seven young (23 +/- 1 yr) and seven older (70 +/- 3 yr) men were head-up tilted to 60 degrees in a thermoneutral condition and during passive heating with water-perfused suits. Measurements included heart rate (HR), cardiac output (Qc; acetylene rebreathing technique), central venous pressure (CVP), blood pressures, forearm blood flow (venous occlusion plethysmography), splanchnic and renal blood flows (indocyanine green and p-aminohippurate clearance), and esophageal and mean skin temperatures. In response to tilting in the thermoneutral condition, CVP and stroke volume decreased to a greater extent in the young men, but HR increased more, such that the fall in Qc was similar between the two groups in the upright posture. The rise in splanchnic vascular resistance (SVR) was greater in the older men, but the young men increased forearm vascular resistance (FVR) to a greater extent than the older men. The fall in Qc during combined heat stress and tilting was greater in the young compared with older men. Only four of the young men versus six of the older men were able to finish the second tilt without becoming presyncopal. In summary, the older men relied on a greater increase in SVR to compensate for a reduced ability to constrict the skin and muscle circulations (as determined by changes in FVR) during head-up tilting.

  11. Atrial natriuretic peptide decreases blood volume in intact and anephric rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trippodo, N.C.; Chien, Y.W.; Pegram, B.L.

    1986-03-05

    Atrial natriuretic peptide (ANP) reportedly lowers atrial pressure and increases hematocrit, suggesting venodilation and/or decreased blood volume (BV). To examine these possibilities, rat ANP (99-126) was administered to Inactinanesthetized rats (313 +/- 9 g, +/- SE) at 0.5 ..mu..g/kg/min for 30 minutes. Urine flow increased by 0.05 ml/min (p < 0.001) during the last 15 minutes of infusion. Mean arterial pressure (MAP) and thoracic central venous pressure (CVP) decreased (p < 0.001) by 12 and 0.5 mmHg, respectively; hematocrit increased by 4.1 units (p < 0.001) and BV (/sup 51/Cr-RBC) decreased by 3.4 ml/kg (p < 0.001). Mean circulatory fillingmore » pressure, measured by inflating an intracardiac balloon to briefly stop the circulation, did not change. Distribution of BV between the thoracic and spanchnic organs (whole-animal freezing in liquid nitrogen) was not measurably altered. The results suggest that the decrease in CVP was related more to decreased BV than to venodilation. To investigate possible mechanisms for the decreased BV, the same dose of ANP was administered to anephric rats. MAP decreased by 8 mmHg (p < 0.001); hematocrit increased by 2.4 units (p < 0.001) and BV decreased by 1.7 ml/kg (p < 0.05). The results indicate that short-term administration of ANP decreases blood volume by causing intravascular fluid to shift into the interstitium as well as by inducing diuresis.« less

  12. Physical Therapists’ Perceptions of Knowledge and Clinical Behavior Regarding Cardiovascular Disease Prevention

    PubMed Central

    Van Zant, R Scott; Cape, Kelly Jo; Roach, Katrina; Sweeney, Janie

    2013-01-01

    Purpose The study purpose was to assess perceptions of physical therapists (PTs) regarding the role of physical therapy in cardiovascular disease (CVD) prevention. Methods A 25-item survey, validated by expert cardiovascular/pulmonary (CVP) PTs, was sent electronically to 2,673 PTs. Each item represented an element of clinical practice behavior: education of CVD/risk factors (EDCVD), administration of primary CVD prevention (PRECVD), identifying underlying CVD/risk factors (IDCVD), monitoring CV status in patients with CVD (MONCVD). Responses were assigned numeric values (strongly agree = 5 to strongly disagree = 1), and mean element scores were analyzed. Results Most of the 516 respondents were APTA Section members (34% CVP Section, 42% other Section membership) and worked in academia (53%). Items showing a high (> 95%) level of agreement included patient education of smoking (97%) and monitoring exercise intensity (99%), assessing exercise benefits (99%), clinically identifying obesity (97%) and hypertension (97%), and monitoring CV response to exercise (99%). Items failing to reach 80% overall agreement were patient education of CVD medications (79%) and blood chemistry (72%), and assessing CVD family history (75%), patient BMI (60%), and body composition (33%). Identifying underlying CVD (77.2%) was the only practice behavior failing to reach 80% agreement. Outpatient PTs agreed significantly less to all elements vs. academics, and to IDCVD vs. all PTs except home health. Conclusions Physical therapists support most CVD prevention behaviors, but not given elements of patient education and identifying underlying CVD/risk factors. PMID:23801901

  13. A porcine model for acute ischaemic right ventricular dysfunction.

    PubMed

    Haraldsen, Pernille; Lindstedt, Sandra; Metzsch, Carsten; Algotsson, Lars; Ingemansson, Richard

    2014-01-01

    To establish an experimental model for acute ischaemic isolated right ventricular dysfunction and the subsequent haemodynamic changes. An open-chest porcine model with ischaemic dysfunction of the right ventricle induced by ligation of the three main branches supporting the right ventricular free wall. Invasive monitoring of mean arterial blood pressure (MAP), central venous pressure (CVP), left atrial pressure (LAP) and right ventricular pressure (RVP); ultrasonic measurement of cardiac output (CO) and calculation of haemodynamic parameters such as stroke volume (SV), systemic vascular resistance (SVR), pulmonary vascular resistance (PVR) and right ventricular stroke work (RVSW) using standard formulae. The ischaemic challenge to the right ventricle resulted in a significant (≥30%) reduction in RVSW associated with an increase (6-25%) in CVP and reduction (8-18%) in pulmonary artery pressure (PAP) despite unchanged PVR, all reflecting the failing right ventricle. There was also a significant drop in CO (14-22%) despite unchanged LAP indicating lessened transpulmonary delivery of left ventricular preload due to the failing right ventricle causing the haemodynamic compromise rather than left ventricular failure. Supraventricular and ventricular arrhythmias occurred in three and two out of seven pigs, respectively-all of which except one were successfully resuscitated with cardioversion and/or defibrillation. This novel open-chest porcine model of induced ischaemia of the right ventricular free wall resulted in significant haemodynamic compromise confirmed using standard haemodynamic measurements making it useful for further research on acute, ischaemic isolated right ventricular failure.

  14. [Applied studies of structured triglycerides for parenteral nutrition in severe hemorrhagic shock patients after resuscitation].

    PubMed

    Su, Mao-sheng; He, Lei; Liu, Zhi-wei; Ma, Huan-xian; Zhao, Qing-hua; Zhang, Wen-zhi

    2012-03-27

    To evaluate the effects of structured triglycerides in parenteral nutrition versus a physical medium-chain triglycerides (MCT)/long-chain triglycerides (LCT) mixture on severe hemorrhagic shock patients after resuscitation. In a randomized trial, we studied 20 critical patients with a total blood loss of over 3000 ml perioperatively and/or intraoperatively. The use of triglycerides started from Day 3 postoperation and parenteral nutrition lasted for no less than 5 days. They were allocated to receive one of two nutrition regiments: structured triglycerides in Group A (n = 10) and MCT/LCT in Group B (n = 10). There were no significant differences of general conditions in two groups. Before the start of parenteral nutrition (d0), d1 d3 and d5 after start of infusion, the following parameters were measured: hemoglobin (Hb), platelet count (Plt), alanine aminotransferase (ALT), total bilirubin (TB), direct bilirubin (DB), serum triglycerides (TG), prealbumin (PA) and transferrin (TF). And mean artery pressure (MAP), heart rate (HR) and central vein pressure (CVP) were also recorded at the same time-points. Then the post-TG changes of the above data were compared in both groups. After the use of triglycerides, there were no significant differences of MAP, HR, CVP, Hb and Plt in both groups (P > 0.05). At D3 and D5, the serum levels of TG ((2.1 ± 0.4) vs (1.6 ± 0.6) mg/L, (2.3 ± 0.7) vs (1.5 ± 0.3) mg/L) and alanine aminotransferase ((133 ± 58) vs (97 ± 26) U/L; (116 ± 48) vs (77 ± 31) U/L) were significantly higher in Group B versus those receiving structured triglycerides in Group A (P < 0.05). TB ((18 ± 15) vs (18 ± 11) µmol/L) and DB ((8.9 ± 3.2) vs (8.8 ± 2.5) µmol/L) had no significant differences in two groups (P > 0.05). The serum levels of such nutrition markers as PA ((195 ± 55) vs (166 ± 55) mg/L,(245 ± 53) vs (195 ± 58) mg/L) and TF ((2.6 ± 0.5) vs (2.5 ± 0.6) g/L, (3.3 ± 0.8) vs (2.9 ± 0.6) g/L)were significantly higher in Group A than those in Group B (P < 0.05). With regards to lipid metabolism, protein synthesis and hepatocyte protection, structured triglycerides in parenteral nutrition is advantageous to standard MCT/LCT emulsion in severe hemorrhagic shock patients after resuscitation.

  15. Snake constriction rapidly induces circulatory arrest in rats.

    PubMed

    Boback, Scott M; McCann, Katelyn J; Wood, Kevin A; McNeal, Patrick M; Blankenship, Emmett L; Zwemer, Charles F

    2015-07-01

    As legless predators, snakes are unique in their ability to immobilize and kill their prey through the process of constriction, and yet how this pressure incapacitates and ultimately kills the prey remains unknown. In this study, we examined the cardiovascular function of anesthetized rats before, during and after being constricted by boas (Boa constrictor) to examine the effect of constriction on the prey's circulatory function. The results demonstrate that within 6 s of being constricted, peripheral arterial blood pressure (PBP) at the femoral artery dropped to 1/2 of baseline values while central venous pressure (CVP) increased 6-fold from baseline during the same time. Electrocardiographic recordings from the anesthetized rat's heart revealed profound bradycardia as heart rate (fH) dropped to nearly half of baseline within 60 s of being constricted, and QRS duration nearly doubled over the same time period. By the end of constriction (mean 6.5±1 min), rat PBP dropped 2.9-fold, fH dropped 3.9-fold, systemic perfusion pressure (SPP=PBP-CVP) dropped 5.7-fold, and 91% of rats (10 of 11) had evidence of cardiac electrical dysfunction. Blood drawn immediately after constriction revealed that, relative to baseline, rats were hyperkalemic (serum potassium levels nearly doubled) and acidotic (blood pH dropped from 7.4 to 7.0). These results are the first to document the physiological response of prey to constriction and support the hypothesis that snake constriction induces rapid prey death due to circulatory arrest. © 2015. Published by The Company of Biologists Ltd.

  16. Xylazine infusion in isoflurane-anesthetized and ventilated healthy horses: Effects on cardiovascular parameters and intestinal perfusion

    PubMed Central

    Hopster, Klaus; Wittenberg-Voges, Liza; Kästner, Sabine B.R.

    2017-01-01

    To investigate the effects of a xylazine infusion during isoflurane anesthesia on global perfusion parameters and gastrointestinal oxygenation and microperfusion, 8 adult warmblood horses were sedated with xylazine and anesthesia induced with midazolam and ketamine. Horses were mechanically ventilated during anesthesia. After 3 h of stable isoflurane anesthesia (FEIso 1.3 Vol %), a xylazine infusion with 1 mg/kg body weight (BW) per hour was started for 1 h and then stopped. Before, during, and after xylazine infusion, heart rate (HR), arterial blood pressure (MAP), cardiac output (CO), central venous pressure (CVP), and pulmonary artery pressure (PAP) were measured and systemic vascular resistance (SVR) was calculated. Arterial blood gases were taken and oxygen delivery (DO2) and alveolar dead space (VDalv) were calculated. Further intestinal oxygen and microperfusion were measured using white light spectroscopy and laser Doppler flowmetry. Surface probes were placed via median laparotomy on the stomach, the jejunum, and the colon. Wilcoxon rank-sum test was used to compare values over time (P < 0.05). During xylazine infusion, MAP, CVP, PAP, SVR, and VDalv increased significantly, whereas CO, DO2, and intestinal microperfusion decreased. Intestinal oxygenation remained unchanged. All parameters returned to pre-xylazine values within 1 h after stopping xylazine infusion. A xylazine infusion during constant isoflurane anesthesia in horses impairs global and intestinal perfusion without changing tissue oxygenation in normoxic healthy horses. Further studies are necessary, however, to evaluate whether a possible reduction of isoflurane concentration by xylazine infusion will ameliorate these negative effects. PMID:29081581

  17. Multichannel electrogastrography under a magnifying glass--an in-depth study on reproducibility of fed state electrogastrograms.

    PubMed

    Krusiec-Swidergoł, B; Jonderko, K

    2008-06-01

    We checked on reproducibility of parameters of a multichannel electrogastrogram in adults after intake of typical, applied in electrogastrography, test meals. Recordings of multichannel electrogastrograms were accomplished in four blocks comprising 18 subjects (nine healthy volunteers and nine patients with functional GI disorders) each. Every subject had two examinations taken 1-2 days apart, and a third one was accomplished at least 2 weeks before or after the two other sessions. The registration involved a 30-min fasted and a 2-h postprandial period after one of the meal stimuli tested within a given block: 400 mL water, 400 g yoghurt (378 kcal), a scrambled eggs sandwich (370 kcal), a pancake (355 kcal). From among the parameters reflecting the propagation of the gastric slow waves, the average percentage of slow wave coupling (APSWC) exhibited a good (coefficient of variation for paired examinations CV(p) < or = 10%) to moderate (10 < CV(p) < or = 30%) reproducibility. On the other hand, the reproducibility of the maximum dominant frequency difference and the spatial dominant power difference was found to be unsatisfactory. The reproducibility of the multichannel electrogastrographic parameters did not differ between healthy volunteers and patients with functional GI disorders. Gender or the kind of a test meal did not affect the reproducibility of the electrogastrographic parameters either. The medium-term reproducibility was not any worse than the short-term one. From among the parameters of a multichannel electrogastrogram intended to quantify the propagation of slow waves, only the APSWC offers a reproducibility potentially good enough for clinical applications.

  18. Evidence for increased cardiac compliance during exposure to simulated microgravity

    NASA Technical Reports Server (NTRS)

    Koenig, S. C.; Convertino, V. A.; Fanton, J. W.; Reister, C. A.; Gaffney, F. A.; Ludwig, D. A.; Krotov, V. P.; Trambovetsky, E. V.; Latham, R. D.

    1998-01-01

    We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

  19. [Effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection].

    PubMed

    Fan, Yuan-hua; Liu, Yuan-fei; Zhu, Hua-yong; Zhang, Min

    2012-02-01

    To evaluate effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection, based on the protective pulmonary ventilation strategy. Ninety-seven cases with severe pulmonary infection admitted to intensive care unit (ICU) of Ganzhou City People's Hospital undergoing mechanical ventilation were involved. Volume controlled ventilation mode with small tidal volume (8 ml/kg) and positive end-expiratory pressure (PEEP) of 6 cm H(2)O [1 cm H(2)O = 0.098 kPa] was conducted. Each patient underwent recruitment maneuver in supine position and then in prone position [PEEP 20 cm H(2)O+pressure control (PC) 20 cm H(2)O]. Heart rate (HR), mean arterial pressure (MAP), pulse oxygen saturation [SpO(2)] and blood gas analysis data were recorded before and after recruitment maneuver in either position. A double-lumen venous catheter was inserted into internal jugular vein or subclavian vein, and a pulse index contour cardiac output (PiCCO) catheter was introduced into femoral artery. Cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI), intra-thoracic blood volume index (ITBVI), extra vascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), global ejection fraction (GEF), stroke volume variation (SVV) and central vein pressure (CVP) were monitored. (1) Compared with data before recruitment maneuver, there were no significant differences in HR and MAP after supine position and prone position recruitment maneuver, but significant differences in SpO(2) were found between before and after recruitment maneuver when patients' position was changed (supine position: 0.954 ± 0.032 vs. 0.917 ± 0.025, P < 0.05; prone position: 0.982 ± 0.028 vs. 0.936 ± 0.039, P < 0.05). SpO(2) was higher in prone position recruitment maneuver (P < 0.05). (2) Compared with data before recruitment maneuver, CI [L×min(-1)×m(-2)], SVI (ml/m(2)), GEDVI (ml/m(2)) and GEF were decreased significantly during recruitment maneuver (supine position: CI 3.2 ± 0.4 vs. 3.8 ± 0.6, SVI 32.4 ± 5.6 vs. 38.8 ± 6.5, GEDVI 689 ± 44 vs. 766 ± 32, GEF 0.267 ± 0.039 vs. 0.305 ± 0.056; prone position: CI 3.1 ± 0.5 vs. 3.6 ± 0.4, SVI 31.2 ± 5.8 vs. 37.3 ± 5.0, GEDVI 678 ± 41 vs. 758 ± 36, GEF 0.268 ± 0.040 vs. 0.288 ± 0.053, all P < 0.05), and CVP [cm H(2)O] and SVV were significantly increased [supine position: CVP 10.7 ± 1.5 vs. 8.2 ± 2.5, SVV (11.2 ± 3.3)% vs. (8.3 ± 4.7)%; prone position: CVP 10.3 ± 1.8 vs. 8.1 ± 2.5, SVV (12.7 ± 3.4)% vs. (9.1 ± 3.6)%, all P < 0.05], but they returned to the level of that before recruitment maneuver soon after termination of recruitment maneuver. There were no significant differences in SVRI, ITBVI and EVLWI between before and after recruitment maneuver in both positions. There were also no significant differences in above parameters between two positions. Based on the lung protective ventilation strategy of small tidal volume with PEEP, oxygenation was improved and SpO(2) was increased significantly when prone position ventilation combined with lung recruitment method was used in severe pulmonary infection patients. The effect of recruitment maneuver during prone position on hemodynamics was slight, except a temporary decrease of SVI and GEF just during recruitment maneuver.

  20. Comparison of Two Central Venous Pressure Control Strategies to Prevent Atrial Fibrillation After Coronary Artery Bypass Grafting.

    PubMed

    Costa, Mario Augusto Cray da; Lirani, Wesley; Wippich, Ana Caroline; Lopes, Luana; Tolentino, Eduardo de Souza; Zampar, Beatriz; Schafranski, Marcelo Derbli

    2017-04-01

    Atrial fibrillation (AF) takes place in 10-40% of patients undergoing coronary artery bypass grafting (CABG), and increases cardiovascular mortality. Enlargement of atrial chambers is associated with increased AF incidence, so patients with higher central venous pressure (CVP) are expected to have larger atrial distension, which increases AF incidence. To compare post-CABG AF incidence, following two CVP control strategies. Interventional, randomized, controlled clinical study. The sample comprised 140 patients undergoing CABG between 2011 and 2015. They were randomized into two groups, G15 and G20, with CVP maintained ≤ 15 cmH2O and ≤ 20 cmH2O, respectively. 70 patients were included in each group. The AF incidence in G15 was 8.57%, and in G20, 22.86%, with absolute risk reduction of 14.28%, and number needed to treat (NNT) of 7 (p = 0.03). Mortality (G15 = 5.71%; G20 = 11.42%; p = 0.07), hospital length of stay (G15 = 7.14 days; G20 = 8.21 days; p = 0.36), number of grafts (median: G15 = 3, G2 = 2; p = 0.22) and cardiopulmonary bypass use (G15 = 67.10%; G20 = 55.70%; p = 0.22) were statistically similar. Age (p = 0.04) and hospital length of stay (p = 0.001) were significantly higher in patients who developed AF in both groups. Keeping CVP low in the first 72 post-CABG hours reduces the relative risk of AF, and may be useful to prevent AF after CABG. A fibrilação atrial (FA) ocorre em 10-40% dos pacientes submetidos a cirurgia de revascularização miocárdica (RM), e eleva a mortalidade cardiovascular. Como o aumento dos átrios está associado ao aumento da incidência de FA, espera-se que pacientes com pressão venosa central (PVC) mais alta tenham maior distensão atrial, o que eleva a incidência dessa arritmia. Comparar a incidência de FA em pós-operatório de RM, seguindo duas estratégias de controle de PVC. Estudo clínico randomizado controlado intervencionista. A amostra foi composta por 140 pacientes submetidos a RM entre 2011 e 2015. Os pacientes foram randomizados em dois grupos, G15 e G20, mantidos com PVC máxima de 15 cmH2O e 20 cmH2O, respectivamente. Foram incluídos 70 pacientes em cada grupo. A incidência da arritmia em G15 foi de 8,57% e, no G20, de 22,86%, com redução de risco absoluto de 14,28% e número necessário para tratar (NNT) de 7 (p = 0,03). Mortalidade (G15 = 5,71%; G20 = 11,42%; p = 0,07), tempo de internamento (G15 = 7,14 dias; G20 = 8,21 dias; p = 0,36), número de enxertos (medianas: G15 = 3, G2 = 2; p = 0,22) e uso de circulação extracorpórea (G15 = 67,10%; G20 = 55,70%; p = 0,22) mostraram-se estatisticamente semelhantes. A idade (p = 0,04) e o tempo de internamento (p = 0,001) foram significativamente maiores nos pacientes que desenvolveram FA nos dois grupos. Manter a PVC com valores mais baixos nas primeiras 72h após a cirurgia de RM reduz o risco relativo de FA e pode ser uma ferramenta útil na prevenção da FA após RM.

  1. The Impacts of Various Types of Advertising Media, Demographics, and Recruiters on Quality Enlistments: Results from Simultaneous and Heteroscedastic Models.

    DTIC Science & Technology

    1980-07-01

    Dollars of expenditures tn .4895 .0124 39.389 .872 1967 dollars for printed materials per labor force mem - ber for the General Enlisted General...0 04 -HdC 14 J Q) W )L4 r-4 4 0 W 0 -1 𔃾- 0 C0)4 wC404 a. ) - 3w 0 ~~~~ .o4- .C 44.4 Ir 0C -r0-Cv-P 0r4- r0 vi a) w - 0 oHp tow)* *’- i CD C4 4 r-4

  2. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    PubMed

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Hospitalists' ability to use hand-carried ultrasound for central venous pressure estimation after a brief training intervention: a pilot study.

    PubMed

    Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A

    2013-12-01

    Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.

  4. Coagulation changes during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2015-11-01

    We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.

  5. Effects of milrinone and epinephrine or dopamine on biventricular function and hemodynamics in right heart failure after pulmonary regurgitation.

    PubMed

    Hyldebrandt, Janus Adler; Agger, Peter; Sivén, Eleonora; Wemmelund, Kristian Borup; Heiberg, Johan; Frederiksen, Christian Alcaraz; Ravn, Hanne Berg

    2015-09-01

    Right ventricular failure (RVF) secondary to pulmonary regurgitation (PR) impairs right ventricular (RV) function and interrupts the interventricular relationship. There are few recommendations for the medical management of severe RVF after prolonged PR. PR was induced in 16 Danish landrace pigs by plication of the pulmonary valve leaflets. Twenty-three pigs served as controls. At reexamination the effect of milrinone, epinephrine, and dopamine was evaluated using biventricular conductance and pulmonary catheters. Seventy-nine days after PR was induced, RV end-diastolic volume index (EDVI) had increased by 33% (P = 0.006) and there was a severe decrease in the load-independent measurement of contractility (PRSW) (-58%; P = 0.003). Lower cardiac index (CI) (-28%; P < 0.0001), mean arterial pressure (-15%; P = 0.01) and mixed venous oxygen saturation (SvO2) (36%; P < 0.0001) were observed compared with the control group. The interventricular septum deviated toward the left ventricle (LV). Milrinone improved RV-PRSW and CI and maintained systemic pressure while reducing central venous pressure (CVP). Epinephrine and dopamine further improved biventricular PRSW and CI equally in a dose-dependent manner. Systemic and pulmonary pressures were higher in the dopamine-treated animals compared with epinephrine-treated animals. None of the treatments improved stroke volume index (SVI) despite increases in contractility. Strong correlation was detected between SVI and LV-EDVI, but not SVI and biventricular contractility. In RVF due to PR, milrinone significantly improved CI, SvO2, and CVP and increased contractility in the RV. Epinephrine and dopamine had equal inotropic effect, but a greater vasopressor effect was observed for dopamine. SV was unchanged due to inability of both treatments to increase LV-EDVI. Copyright © 2015 the American Physiological Society.

  6. Randomized Comparative Study of Intravenous Infusion of Three Different Fixed Doses of Milrinone in Pediatric Patients with Pulmonary Hypertension Undergoing Open Heart Surgery

    PubMed Central

    Barnwal, Neeraj Kumar; Umbarkar, Sanjeeta Rajendra; Sarkar, Manjula Sudeep; Dias, Raylene J

    2017-01-01

    Background: Pulmonary hypertension secondary to congenital heart disease is a common problem in pediatric patients presenting for open heart surgery. Milrinone has been shown to reduce pulmonary vascular resistance and pulmonary artery pressure in pediatric patients and neonates postcardiac surgery. We aimed to evaluate the postoperative outcome in such patients with three different fixed maintenance doses of milrinone. Methodology: Patients were randomized into three groups. All patients received fixed bolus dose of milrinone 50 μg/kg on pump during rewarming. Following this, patients in low-dose group received infusion of milrinone at the rate of 0.375 μg/kg/min, medium-dose group received 0.5 μg/kg/min, and high-dose group received 0.75 μg/kg/min over 24 h. Heart rate, mean arterial pressure (MAP), mean airway pressure (MaP), oxygenation index (OI), and central venous pressure (CVP) were compared at baseline and 24 h postoperatively. Dose of inotropic requirement, duration of ventilatory support and Intensive Care Unit (ICU) stay were noted. Results: MAP, MaP, OI, and CVP were comparable in all three groups postoperatively. All patients in the low-dose group required low inotropic support while 70% of patients in the high-dose group needed high inotropic support to manage episodes of hypotension (P = 0.000). Duration of ventilatory support and ICU stay in all three groups was comparable (P = 0.412, P = 0.165). Conclusion: Low-dose infusions while having a clinical impact were more beneficial in avoiding adverse events and decreasing inotropic requirement without affecting duration of ventilatory support and duration of ICU stay. PMID:28701597

  7. Randomized comparative study of intravenous infusion of three different fixed doses of milrinone in pediatric patients with pulmonary hypertension undergoing open heart surgery.

    PubMed

    Barnwal, Neeraj Kumar; Umbarkar, Sanjeeta Rajendra; Sarkar, Manjula Sudeep; Dias, Raylene J

    2017-01-01

    Pulmonary hypertension secondary to congenital heart disease is a common problem in pediatric patients presenting for open heart surgery. Milrinone has been shown to reduce pulmonary vascular resistance and pulmonary artery pressure in pediatric patients and neonates postcardiac surgery. We aimed to evaluate the postoperative outcome in such patients with three different fixed maintenance doses of milrinone. Patients were randomized into three groups. All patients received fixed bolus dose of milrinone 50 μg/kg on pump during rewarming. Following this, patients in low-dose group received infusion of milrinone at the rate of 0.375 μg/kg/min, medium-dose group received 0.5 μg/kg/min, and high-dose group received 0.75 μg/kg/min over 24 h. Heart rate, mean arterial pressure (MAP), mean airway pressure (MaP), oxygenation index (OI), and central venous pressure (CVP) were compared at baseline and 24 h postoperatively. Dose of inotropic requirement, duration of ventilatory support and Intensive Care Unit (ICU) stay were noted. MAP, MaP, OI, and CVP were comparable in all three groups postoperatively. All patients in the low-dose group required low inotropic support while 70% of patients in the high-dose group needed high inotropic support to manage episodes of hypotension (P = 0.000). Duration of ventilatory support and ICU stay in all three groups was comparable (P = 0.412, P = 0.165). Low-dose infusions while having a clinical impact were more beneficial in avoiding adverse events and decreasing inotropic requirement without affecting duration of ventilatory support and duration of ICU stay.

  8. Effectiveness of treatment based on PiCCO parameters in critically ill patients with septic shock and/or acute respiratory distress syndrome: a randomized controlled trial.

    PubMed

    Zhang, Zhongheng; Ni, Hongying; Qian, Zhixian

    2015-03-01

    To compare treatment based on either PiCCO-derived physiological values or central venous pressure (CVP) monitoring, we performed a prospective randomized controlled trial with group sequential analysis. Consecutive critically ill patients with septic shock and/or ARDS were included. The planned total sample size was 715. The primary outcome was 28-day mortality after randomization. Participants underwent stratified randomization according to the classification of ARDS and/or septic shock. Caregivers were not blinded to the intervention, but participants and outcome assessors were blinded to group assignment. The study was stopped early because of futility after enrollment of 350 patients including 168 in the PiCCO group and 182 in the control group. There was no loss to follow-up and data from all enrolled participants were analyzed. The result showed that treatment based on PiCCO-derived physiological values was not able to reduce the 28-day mortality risk (odds ratio 1.00, 95 % CI 0.66-1.52; p = 0.993). There was no difference between the two groups in secondary outcomes such as 14-day mortality (40.5 vs. 41.2 %; p = 0.889), ICU length of stay (median 9 vs. 7.5 days; p = 0.598), days free of vasopressors (median 14.5 vs. 19 days; p = 0.676), and days free of mechanical ventilation (median 3 vs. 6 days; p = 0.168). No severe adverse event was reported in both groups. On the basis of our study, PICCO-based fluid management does not improve outcome when compared to CVP-based fluid management.

  9. Children First Study: how an educational program in cardiovascular prevention at school can improve parents' cardiovascular risk.

    PubMed

    Fornari, Luciana S; Giuliano, Isabela; Azevedo, Fernanda; Pastana, Adriana; Vieira, Carolina; Caramelli, Bruno

    2013-04-01

    To evaluate whether a multidisciplinary educational program (EP) in cardiovascular prevention (CVP) for children could improve the Framingham cardiovascular risk (FCR) of their parents after one year. This was a prospective community-based study in Brazil during 2010 that randomized students aged 6 to 10 years old to two different approaches to receiving healthy lifestyle information. The control group received written educational material (EM) for their parents about healthy lifestyle. The intervention group received the same EM for parents, and children were exposed to a weekly EP in CVP with a multidisciplinary health team. At onset and end of the study, we collected data from parents and children (weight, height, arterial blood pressure, and laboratory tests). We studied 197 children and 323 parents. Analyzing the parents' FCR we found that 9.3% of the control group and 6.8% of the intervention group had more than a 10% year risk of cardiovascular heart disease (CHD) over the next 10 years. After the children's EP for the year, the intervention group had a reduction of 91% in the intermediate/high FCR group compared with a 13% reduction in the control group, p = 0.002). In the same way, analyzing the FCR of all parents, there was a reduction of the average risk in the intervention group (3.6% to 2.8% respectively, p < 0.001) compared with the control group (4.4% to 4.4%, p = 0.98). An educational program in cardiovascular prevention directed at school-age children can reduce the FCR risk of their parents, especially in the intermediate/high risk categories.

  10. Bladder pain induced by prolonged peripheral alpha 1A adrenoceptor stimulation involves the enhancement of transient receptor potential vanilloid 1 activity and an increase of urothelial adenosine triphosphate release.

    PubMed

    Matos, R; Cordeiro, J M; Coelho, A; Ferreira, S; Silva, C; Igawa, Y; Cruz, F; Charrua, A

    2016-12-01

    Pathophysiological mechanisms of chronic visceral pain (CVP) are unknown. This study explores the association between the sympathetic system and bladder nociceptors activity by testing the effect of a prolonged adrenergic stimulation on transient receptor potential vanilloid 1 (TRPV1) activity and on urothelial adenosine triphosphate (ATP) release. Female Wistar rats received saline, phenylephrine (PHE), PHE + silodosin, PHE + naftopidil or PHE + prazosin. TRPV1 knockout and wild-type mice received saline or PHE. Visceral pain behaviour tests were performed before and after treatment. Cystometry was performed, during saline and capsaicin infusion. Fos immunoreactivity was assessed in L6 spinal cord segment. Human urothelial ATP release induced by mechanical and thermal stimulation was evaluated. Subcutaneous, but not intrathecal, PHE administration induced pain, which was reversed by silodosin, a selective alpha 1A adrenoceptor antagonist, but not by naftopidil, a relatively selective antagonist for alpha 1D adrenoceptor. Silodosin also reversed PHE-induced bladder hyperactivity and L6 spinal cord Fos expression. Thus, in subsequent experiments, only silodosin was used. Wild-type, but not TRPV1 knockout, mice exhibited phenylephrine-induced pain. Capsaicin induced a greater increase in voiding contractions in PHE-treated rats than in control animals, and silodosin reversed this effect. When treated with PHE, ATP release from human urothelial cells was enhanced either by mechanical stimulation or by lowering the thermal threshold of urothelial TRPV1, which becomes abnormally responsive at body temperature. This study suggests that the activation of peripheral alpha 1A adrenoceptors induces CVP, probably through its interaction with TRPV1 and ATP release. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  11. Effects of a Preconditioning Oral Nutritional Supplement on Pig Livers after Warm Ischemia

    PubMed Central

    Nickkholgh, Arash; Li, Zhanqing; Yi, Xue; Mohr, Elvira; Liang, Rui; Mikalauskas, Saulius; Gross, Marie-Luise; Zorn, Markus; Benzing, Steffen; Schneider, Heinz; Büchler, Markus W.; Schemmer, Peter

    2012-01-01

    Background. Several approaches have been proposed to pharmacologically ameliorate hepatic ischemia/reperfusion injury (IRI). This study was designed to evaluate the effects of a preconditioning oral nutritional supplement (pONS) containing glutamine, antioxidants, and green tea extract on hepatic warm IRI in pigs. Methods. pONS (70 g per serving, Fresenius Kabi, Germany) was dissolved in 250 mL tap water and given to pigs 24, 12, and 2 hrs before warm ischemia of the liver. A fourth dose was given 3 hrs after reperfusion. Controls were given the same amount of cellulose with the same volume of water. Two hours after the third dose of pONS, both the portal vein and the hepatic artery were clamped for 40 min. 0.5, 3, 6, and 8 hrs after reperfusion, heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), portal venous flow (PVF), hepatic arterial flow (HAF), bile flow, and transaminases were measured. Liver tissue was taken 8 hrs after reperfusion for histology and immunohistochemistry. Results. HR, MAP, CVP, HAF, and PVF were comparable between the two groups. pONS significantly increased bile flow 8 hrs after reperfusion. ALT and AST were significantly lower after pONS. Histology showed significantly more severe necrosis and neutrophil infiltration in controls. pONS significantly decreased the index of immunohistochemical expression for TNF-α, MPO, and cleaved caspase-3 (P < 0.001). Conclusion. Administration of pONS before and after tissue damage protects the liver from warm IRI via mechanisms including decreasing oxidative stress, lipid peroxidation, apoptosis, and necrosis. PMID:22791934

  12. Validation of lower body negative pressure as an experimental model of hemorrhage

    PubMed Central

    Shade, Robert E.; Muniz, Gary W.; Bauer, Cassondra; Goei, Kathleen A.; Pidcoke, Heather F.; Chung, Kevin K.; Cap, Andrew P.; Convertino, Victor A.

    2013-01-01

    Lower body negative pressure (LBNP), a model of hemorrhage (Hem), shifts blood to the legs and elicits central hypovolemia. This study compared responses to LBNP and actual Hem in sedated baboons. Arterial pressure, pulse pressure (PP), central venous pressure (CVP), heart rate, stroke volume (SV), and +dP/dt were measured. Hem steps were 6.25%, 12.5%, 18.75%, and 25% of total estimated blood volume. Shed blood was returned, and 4 wk after Hem, the same animals were subjected to four LBNP levels which elicited equivalent changes in PP and CVP observed during Hem. Blood gases, hematocrit (Hct), hemoglobin (Hb), plasma renin activity (PRA), vasopressin (AVP), epinephrine (EPI), and norepinephrine (NE) were measured at baseline and maximum Hem or LBNP. LBNP levels matched with 6.25%, 12.5%, 18.75%, and 25% hemorrhage were −22 ± 6, −41 ± 7, −54 ± 10, and −71 ± 7 mmHg, respectively (mean ± SD). Hemodynamic responses to Hem and LBNP were similar. SV decreased linearly such that 25% Hem and matching LBNP caused a 50% reduction in SV. Hem caused a decrease in Hct, Hb, and central venous oxygen saturation (ScvO2). In contrast, LBNP increased Hct and Hb, while ScvO2 remained unchanged. Hem caused greater elevations in AVP and NE than LBNP, while PRA, EPI, and other hematologic indexes did not differ between studies. These results indicate that while LBNP does not elicit the same effect on blood cell loss as Hem, LBNP mimics the integrative cardiovascular response to Hem, and validates the use of LBNP as an experimental model of central hypovolemia associated with Hem. PMID:24356525

  13. Temporal patterns of radiographic infiltration in severely traumatized patients with and without adult respiratory distress syndrome.

    PubMed

    Johnson, K S; Bishop, M H; Stephen, C M; Jorgens, J; Shoemaker, W C; Shori, S K; Ordog, G; Thadepalli, H; Appel, P L; Kram, H B

    1994-05-01

    We prospectively evaluated the patterns of pulmonary structural and functional changes in 100 consecutive surgical intensive care unit trauma patients who had (1) emergent major surgery, (2) a pelvic fracture, or (3) two or more major long bone fractures. For each patient, arterial blood gas measurements (ABGs), central venous pressure (CVP), pulmonary capillary occlusion pressure (PAOP), thoracic compliance, arterial oxygen tension/fraction of inspired oxygen (PAO2/FIO2), pulmonary venous admixture (Qs/Qt), and portable chest roentgenograms were sequentially tracked. The senior staff radiologist interpreted all chest roentgenograms. Pulmonary infiltration was quantitated in each of six fields using a scale ranging from 0 to 4, with 0 being no infiltration and 4 being the maximum. Adult respiratory distress syndrome (ARDS) was defined as follows: Qs/Qt > or = 20%, PAO2/FIO2 < 250 or both; dependence on mechanical ventilation for life support for > or = 24 hours; PAOP or CVP or both < 20 mm Hg; and thoracic compliance < 50 mL/cm H2O. Time zero (T0) the time of onset of ARDS, was defined as the time these criteria were met. Eighty-three of 100 study group patients had penetrating injuries, and 17 were admitted with blunt trauma. Fifty-one of 100 patients developed ARDS: 36 of 51 died. Only 4 of 49 (8%) patients without ARDS died. The injured lungs of patients with and without ARDS had similar amounts of infiltration over most measured time intervals. The noninjured lungs of the ARDS patients, however, had significantly greater infiltration than those without ARDS at T0 and over subsequent time intervals.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Portal hypertension and liver cirrhosis in rats: effect of the β3-adrenoceptor agonist SR58611A

    PubMed Central

    Vasina, Valentina; Giannone, Ferdinando; Domenicali, Marco; Latorre, Rocco; Berzigotti, Annalisa; Caraceni, Paolo; Zoli, Marco; De Ponti, Fabrizio; Bernardi, Mauro

    2012-01-01

    BACKGROUND AND PURPOSE β3-Adrenoceptors participate in the regulation of vascular tone in physiological and pathological conditions. We aimed to assess the effect of pharmacological modulation of β3-adrenoceptors on portal pressure (PP) and systemic haemodynamics and their expression in the liver and mesenteric vessels of cirrhotic rats. EXPERIMENTAL APPROACH PP, central venous pressure (CVP) and systemic haemodynamics were invasively assessed in control and CCl4-treated cirrhotic rats before and during infusion of the selective β3-adrenoceptor agonist, SR58611A. Tissue samples were also collected from liver, heart, portal vein and mesenteric artery for immunohistochemistry and molecular biology analysis. The effect of SR58611A on isolated portal vein was assessed. KEY RESULTS At baseline, cirrhotic rats showed portal hypertension, reduced CVP and hyperdynamic circulation. SR58611A induced a significant, dose-dependent decrease in PP in cirrhotic rats, but not in controls. Although both groups manifested a dose-dependent reduction in mean arterial pressure, this effect was associated with decreased cardiac index (CI) and unchanged indicized peripheral vascular resistance (PVRI) in cirrhotic rats and increased CI and decreased PVRI in control animals. Pretreatment with the selective β3-adrenoceptor antagonist SR59230 prevented all SR58611A-induced changes in cirrhotic rats. SR58611A concentration-dependently relaxed portal vein in cirrhotic rats to a significantly greater extent than in healthy rats; pretreatment with SR59230A completely prevented SR58611A-induced cirrhotic portal vein relaxation. Finally, β3-adrenoceptors were identified in the liver, heart and portal vein of cirrhotic and control animals; their expression was increased in cirrhotic rats. CONCLUSIONS AND IMPLICATIONS β3-Adrenoceptors are altered in portal hypertension of experimental cirrhosis and may represent a novel therapeutic target. PMID:22708587

  15. Knowledge of nursing students about central venous catheters.

    PubMed

    Mlinar, Suzana; Malnarsić, Rosanda Rasković

    2012-04-01

    Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  16. Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.

    PubMed

    Xu, Zifeng; Zhang, Jianhai; Xia, Yunfei; Deng, Xiaoming

    2014-01-01

    To observe the change of PVI after thoracic epidural block on the basis of general anesthesia. In 26 patients undergoing elective upper abdominal operations, changes of SVI, PVI, SVV, PPV and CVP were monitored immediately before and 10 minutes after T8-9 thoracic epidural anesthesia on the basis of general anesthesia. The definition was that patients with ΔSVI greater than 10% belonged to response group to epidural block. Before epidural block, the PVI, SVV and PPV baseline values in patients of response group were significantly higher than those in patients of non-response group. PVI, SVV and PPV after epidural block were significantly higher than immediately before epidural block (P < 0.001). PVI, SVV and PPV baseline values immediately before epidural block were positively correlated with ΔSVI; the correlation coefficients were 0.70, 0.71 and 0.63, respectively, P ≤ 0.001. The optimal critical values for PVI, SVV and PPV to predict response to T8-9 gap epidural block under general anesthesia were 16% (sensitivity 80%, specificity 92%), 13% (sensitivity 90%, specificity 62%) and 12% (sensitivity 90%, specificity 77%), respectively. PVI can be used as a noninvasive indictor to monitor volume change after thoracic epidural block on the basis of general anesthesia.

  17. [Effects of lung protective ventilation strategy combined with lung recruitment maneuver on patients with severe burn complicated with acute respiratory distress syndrome].

    PubMed

    Li, Xiaojian; Zhong, Xiaomin; Deng, Zhongyuan; Zhang Xuhui; Zhang, Zhi; Zhang, Tao; Tang, Wenbin; Chen, Bib; Liu, Changling; Cao, Wenjuan

    2014-08-01

    To investigate the effects of lung protective ventilation strategy combined with lung recruitment maneuver on ARDS complicating patients with severe burn. Clinical data of 15 severely burned patients with ARDS admitted to our burn ICU from September 2011 to September 2013 and conforming to the study criteria were analyzed. Right after the diagnosis of acute lung injury/ARDS, patients received mechanical ventilation with lung protective ventilation strategy. When the oxygenation index (OI) was below or equal to 200 mmHg (1 mmHg = 0. 133 kPa), lung recruitment maneuver was performed combining incremental positive end-expiratory pressure. When OI was above 200 mmHg, lung recruitment maneuver was stopped and ventilation with lung protective ventilation strategy was continued. When OI was above 300 mmHg, mechanical ventilation was stopped. Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, variables of blood gas analysis (pH, PaO2, and PaCO2) were obtained by blood gas analyzer, and the OI values were calculated; hemodynamic parameters including heart rate, mean arterial pressure (MAP), central venous pressure (CVP) of all patients and the cardiac output (CO), extravascular lung water index (EVLWI) of 4 patients who received pulse contour cardiac output (PiCCO) monitoring were monitored. Treatment measures and outcome of patients were recorded. Data were processed with analysis of variance of repeated measurement of a single group and LSD test. (1) Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the levels of PaO2 and OI of patients were respectively (77 ± 8), (113 ± 5), (142 ± 6) mmHg, and (128 ± 12), (188 ± 8), (237 ± 10) mmHg. As a whole, levels of PaO2 and OI changed significantly at different time points (with F values respectively 860. 96 and 842. 09, P values below 0. 01); levels of pH and PaCO2 showed no obvious changes (with F values respectively 0.35 and 3.13, P values above 0.05). (2) Levels of heart rate, MAP, CVP of all patients and CO of 4 patients who received PiCCO monitoring showed no significant changes at different time points (with F values from 0. 13 to 4. 26, P values above 0.05). Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the EVLWI values of 4 patients who received PiCCO monitoring were respectively (13.5 ± 1.3), (10.2 ± 1.0), (7.0 ± 0.8) mL/kg ( F =117.00, P <0.01). (3) The patients received mechanical ventilation at 2 to 72 h after burn, lasting for 14-32 (21 ± 13) d. At post injury day 3-14 (7 ± 5) d, lung recruitment maneuver was applied for 2-5 (3.0 ± 2.0) d. All 15 patients recovered without other complications. Lung protective ventilation strategy combining lung recruitment maneuver can significantly improve the oxygenation in patients with severe burn complicated with ARDS and may therefore improve the prognosis.

  18. Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)

    NASA Technical Reports Server (NTRS)

    Pantalos, George; Sharp, M. Keith; Mathias, John R.; Hargens, Alan R.; Watenpaugh, Donald E.; Buckey, Jay C.

    1999-01-01

    The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.

  19. A Comparison of Two Patient Classification Systems in Determining Nursing Care Hour Requirements

    DTIC Science & Technology

    1985-07-01

    checks q2h or x 12 (3) Neuro checks q4h or x 6 6) Neuro checks q2h or x 12- (2) CVP or rCp (manual) q2h or x 12 ( 6) Cardiac/apnea/temp/pressure...turn q2h) - ( 8) Peds recreation/observation - 5 yearS (exclude NBN) (4) - Isolation (Mask and Gown) I FEEDING ( 5) Tube feed adult/child/ neonate g4h or...x 6 (10) Tube feed adult/child/ neonate q2h or x 12 6) Adult meals > 5 years (spoon feed x 3) (10) Child meals < 5 years (spoon feed x 3) (2) Infant

  20. Anaesthesia for caesarean section in patients with cardiac disease.

    PubMed

    Chohan, Ursula; Afshan, Gauhar; Mone, Abdul

    2006-01-01

    This review contains material sourced from Med-Line and Pub-Med, search year 2002-2004. Material selected was pertaining to common cardiac ailments in pregnancy. Congenital cardiac problems i.e. Tetralogy of Fallot (TOF), Atrial Septal Defect (ASD), Ventricular Septal Defect (VSD), Eisenmengers syndrome, valvular heart disease, i.e. mitral stenosis, mitral regurgitation, aortic stensois and aortic regurgitation are discussed. Other cardiac conditions associated with pregnancy are pulmonary hypertension and peri-partum cardiomyopathy. Arrhythmias during pregnancy, vary from isolated premature to supra-ventricular and ventricular tachycardia, management is similar to non-pregnant patients. This review summarizes the current management of a parturient with cardiac disease requiring surgical delivery. Regional anaesthesia techniques are preferred as reflected in the current literature for patient with cardiac disease with minor alterations such as slow establishment of epidural for caesarean section or continuous spinal anaesthesia with very small incremental doses of local anaesthesia, maintaining the patient's SVR with vasopressors and fluid, monitoring of the fluid regimen with CVP and in some cardiac function with Swan Ganz catheter. Patients with Eisenmenger syndrome, pulmonary hypertension, should be advised to avoid pregnancy. In conclusion with vast advancements in obsterics care, improvements in cardiac surgery, many patients with cardiac disease can now be safely delivered surgically by skillful anaesthesiologists who are aware of the common potential intra-operative problems and the ability to respond to undesired events immediately.

  1. Cardiovascular effects of a continuous rate infusion of lidocaine in calves anesthetized with xylazine, midazolam, ketamine and isoflurane.

    PubMed

    Araújo, Marcelo A; Dias, Bianca P; Bovino, Fernanda; Deschk, Maurício; Abimussi, Caio Jx; Oliva, Valéria Nls; Rodrigues, Celso A; Santos, Paulo Sp

    2014-03-01

    To assess the cardiovascular changes of a continuous rate infusion of lidocaine in calves anesthetized with xylazine, midazolam, ketamine and isoflurane during mechanical ventilation. Prospective, randomized, cross-over, experimental trial. A total of eight, healthy, male Holstein calves, aged 10 ± 1 months and weighing 114 ± 11 kg were included in the study. Calves were administered xylazine followed by ketamine and midazolam, orotracheal intubation and maintenance on isoflurane (1.3%) using mechanical ventilation. Forty minutes after induction, lidocaine (2 mg kg⁻¹ bolus) or an equivalent volume of saline (0.9%) was administered IV followed by a continuous rate infusion (100 μg kg⁻¹ minute⁻¹) of lidocaine (treatment L) or saline (treatment C). Heart rate (HR), systolic, diastolic and mean arterial pressures (SAP, DAP and MAP), central venous pressure (CVP), mean pulmonary arterial pressure (mPAP), pulmonary arterial occlusion pressure (PAOP), cardiac output, end-tidal carbon dioxide (Pe'CO2 ) and core temperature (CT) were recorded before lidocaine or saline administration (Baseline) and at 20-minute intervals (T20-T80). Plasma concentrations of lidocaine were measured in treatment L. The HR was significantly lower in treatment L compared with treatment C. There was no difference between the treatments with regards to SAP, DAP, MAP and SVRI. CI was significantly lower at T60 in treatment L when compared with treatment C. PAOP and CVP increased significantly at all times compared with Baseline in treatment L. There was no significant difference between times within each treatment and between treatments with regards to other measured variables. Plasma concentrations of lidocaine ranged from 1.85 to 2.06 μg mL⁻¹ during the CRI. At the studied rate, lidocaine causes a decrease in heart rate which is unlikely to be of clinical significance in healthy animals, but could be a concern in compromised animals. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  2. Thoracic epidural analgesia in donor hepatectomy: An analysis.

    PubMed

    Koul, Archna; Pant, Deepanjali; Rudravaram, Swetha; Sood, Jayashree

    2018-02-01

    The purpose of this study is to analyze whether supplementation of general anesthesia (GA) with thoracic epidural analgesia (TEA) for right lobe donor hepatectomy is a safe modality of pain relief in terms of changes in postoperative coagulation profile, incidence of epidural catheter-related complications, and timing of removal of epidural catheter. Retrospective analysis of the record of 104 patients who received TEA for right lobe donor hepatectomy was done. Platelet count, international normalized ratio, alanine aminotransferase, and aspartate aminotransferase were recorded postoperatively until the removal of the epidural catheter. The day of removal of the epidural catheter and visual analogue scale (VAS) scores were also recorded. Any complication encountered was documented. Intraoperatively, central venous pressure (CVP), hemodynamic variables, and volume of intravenous fluids infused were also noted. Statistical analysis was performed by using SPSS statistical package, version 17.0 (SPSS Inc. Chicago, IL). Continuous variables were presented as mean ± standard deviation. A total of 90% of patients had mean VAS scores between 1 and 4 in the postoperative period between days 1 and 5. None of the patients had a VAS score above 5. Although changes in coagulation status were encountered in all patients in the postoperative period, these changes were transient and did not persist beyond postoperative day (POD) 5. There was no delay in removal of the epidural catheter, and the majority of patients had the catheter removed by POD 4. There was no incidence of epidural hematoma. Aside from good intraoperative and postoperative analgesia, TEA in combination with balanced GA and fluid restriction enabled maintenance of low CVP and prevention of hepatic congestion. In conclusion, vigilant use of TEA appears to be safe during donor hepatectomy. Living liver donors should not be denied efficient analgesia for the fear of complications. Liver Transplantation 24 214-221 2018 AASLD. © 2017 by the American Association for the Study of Liver Diseases.

  3. Preoperative Right-Sided Cardiac Congestion Is Associated with Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices.

    PubMed

    Tomizawa, Yutaka; Tanaka, Akiko; Kitahara, Hiroto; Sakuraba, Atsushi; Uriel, Nir; Jeevanandam, Valluvan; Ota, Takeyoshi

    2018-06-01

    Large scale data on preoperative risk stratification for gastrointestinal bleeding (GIB) following continuous-flow left ventricular assist device (CF-LVAD) implantation are scarce. To identify independent predictors for GIB following CF-LVAD implantation. We conducted a retrospective cohort study of consecutive 243 patients who underwent CF-LVAD implantation (HeartMateII) from January 2009 to March 2015 at the University of Chicago Medical Center. GIB was defined as the presence of overt bleeding or occult GIB with ≥ 2 g/dl drop in hemoglobin (Hgb) from recorded baseline values and hemoccult-positive stool. The preoperative and postoperative data were reviewed. Within a median follow-up duration of 408 (IQR 113-954) days, 83 (34%) patients developed GIB after a median of 149 (IQR 27-615) days after implantation of CF-LVAD. There were no significant differences between the groups of GIB and non-GIB with respect to preoperative demographics and comorbidity except for ethnicity. The source of bleeding was identified in 39 (47%) patients and arteriovenous malformation or submucosal streaming vessel was the most frequent cause of bleeding (18/39, 46%). Multivariate-adjusted analysis demonstrated preoperative central venous pressure (CVP) ≥ 18 mmHg (HR 3.56; 95% CI 1.16-10.9; p = 0.026), mean pulmonary artery pressure (mPA) ≥ 36 mmHg (HR 4.14; 95% CI 1.35-12.7; p = 0.013), and the presence of moderate/severe tricuspid valve disease (HR 1.01; 95% CI 1.01-3.86; p = 0.046) were associated with the risk of GIB. In this study, preoperative right-sided cardiac congestion (i.e., increased CVP, mPA and the presence of moderate/severe tricuspid valve disease) was associated with GIB in patients with CF-LVAD.

  4. Intralipid™ administration attenuates the hypotensive effects of acute intravenous amiodarone overdose in a swine model.

    PubMed

    Xanthos, Theodoros; Psichalakis, Nikolaos; Russell, David; Papalois, Apostolos; Koutsovasilis, Anastasios; Athanasopoulos, Dimitrios; Gkiokas, Georgios; Chalkias, Athanasios; Iacovidou, Nicoletta

    2016-08-01

    To investigate whether a lipid emulsion could counteract the hypotensive effects of amiodarone overdose after an acute intravenous administration and improve 4 h survival in an established model of swine cardiovascular research. Twenty pigs were intubated and instrumented to measure aortic pressures and central venous pressures (CVP). After allowing the animals to stabilize for 60 minutes, amiodarone overdose (1 mg/kg/min) was initiated for a maximum of 20 minutes. Afterwards, the animals were randomized into 2 groups. Group A (n = 10) received 0.9% Normal Saline (NS) and Group B (n = 10) received 20% Intralipid® (ILE). A bolus dose of 2 ml/kg in over 2 min time was initially administered in both groups followed by a 45 min infusion (0.2 ml/kg/min) of either NS or ILE. All animals survived the overdose and all animals survived the monitoring period of 4 hours. Systolic aortic pressure (SpthAorta) (6.90 vs 14.10 mmHg, P = .006) and mean arterial pressure (MAP) (6.10 vs 14.90 mmHg, P = .001) were higher in the ILE group 2 min after the bolus ILE infusion. This difference was maintained for 15 min after ILE infusion for both SpthAorta (7.85 vs 13.15 mmHg, P = .044) and MAP (7.85 vs 13.15 mmHg, P = .042). Animals that received ILE had higher CVP (11.6 vs 15.7 mmHg, P = .046), an effect which was attenuated 2 and 4 hours post administration. Animals receiving ILE were more acidotic (7.21 vs 7.38, P = .048) in the monitoring period compared to animals receiving NS. Intralipid attenuated the hypotensive effects of amiodarone toxicity for a period of 15 minutes compared to animals receiving NS. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Effects of graded levels of liquid brewer's yeast on chemical composition and fermentation quality in cassava pulp and rice straw-based total mixed ration silage.

    PubMed

    Kamphayae, Sukanya; Kumagai, Hajime; Bureenok, Smerjai; Narmseelee, Ramphrai; Butcha, Patima

    2017-04-01

    This study aimed to evaluate the effect of liquid brewer's yeast (LBY) addition on chemical composition and fermentation quality of mixture of LBY and cassava pulp (CVP) with rice straw (RS) in different ratios during preservation periods. Four mixtures of LBY, CVP and RS were made, that is mixture ratio of LBY : CVP : RS of 0% LBY, 20% LBY, 35% LBY and 50% LBY were 0:70:30, 20:50:30, 35:35:30 and 50:20:30 as fresh matter, respectively. The bags were opened at weeks 0, 1, 2, 4 and 8 after storage. The contents of dry matter, organic matter, crude protein (CP), ether extract (EE), neutral detergent fiber and acid detergent fiber ranged 36.4-40.0, 88.9-90.8, 4.0-12.0, 1.1-1.3, 58.8-61.6 and 37.6-40.0, respectively, and the contents of CP and EE increased and the other components decreased in proportion to LBY inclusion (P < 0.01). 50% LBY had the highest (P < 0.05) pH (4.81) and ammonia nitrogen per total nitrogen (NH 3 -N/TN) (7.40%) and the lowest V-score (90.3). Propionic and butyric acid contents were 0.01% or lower in each mixture and storage period. There were rapid pH decrease and NH 3 -N/TN increase during the first week of the storage period. The increases of NH 3 -N/TN and acetic acid content and decreases of pH, lactic acid content and V-score during the preservation were more drastic as LBY inclusion increased. Although higher proportion of LBY produced higher CP and lower fiber contents in the mixture, attention should be paid for the reduction of fermentation quality during longer storage periods. © 2016 Japanese Society of Animal Science.

  6. Nandrolone decanoate determines cardiac remodelling and injury by an imbalance in cardiac inflammatory cytokines and ACE activity, blunting of the Bezold-Jarisch reflex, resulting in the development of hypertension.

    PubMed

    Franquni, João Vicente Maggioni; do Nascimento, Andrews Marques; de Lima, Eweliny Miranda; Brasil, Girlândia Alexandre; Heringer, Otávio Arruda; Cassaro, Karla Oliveira Dos Santos; da Cunha, Thony Vinicius Pita; Musso, Carlos; Silva Santos, Maria Carmen L F; Kalil, Ieda Carneiro; Endringer, Denise Coutinho; Boëchat, Giovanna Assis Pereirra; Bissoli, Nazaré Souza; de Andrade, Tadeu Uggere

    2013-03-01

    The aims of this study were to evaluate the effects of nandrolone (ND) on cardiac inflammatory cytokines, ACE activity, troponin I, and the sensitivity of the Bezold-Jarisch reflex (BJR). Male Wistar rats were administered either ND (20 mg/kg; DECA) or vehicle (control animals; CONT) for 4 weeks. BJR was analyzed by measuring the bradycardia and hypotension responses elicited by serotonin administration (2-32 μg/kg). Mean arterial pressure (MAP) was assessed and myocyte hypertrophy was determined by the heart weight/body weight ratio and by morphometric analysis. Matrix collagen deposition was assessed by histological analysis of the picrosirius red-stained samples. Mesenteric vascular reactivity was performed and central venous pressure (CVP) evaluated. Cardiac inflammatory cytokine levels and angiotensin-converting enzyme (ACE) activity were studied as well the biomarker of cardiac lesion, troponin I. DECA group showed enhancement of matrix type I collagen deposition (p < 0.01) and cardiac ACE activity (p < 0.01) compared with the CONT. Interleukin (IL)-10 was reduced (p < 0.01) and pro-inflammatory cytokines (TNF-α and IL-6; p < 0.01) were increased in the DECA group compared with CONT. Cardiac injury was observed in the DECA group shown by the reduction in cardiac troponin I (p < 0.01) compared with the CONT group. Animals in the DECA group also developed myocyte hypertrophy and reduction of BJR sensitivity. The MAP of animals treated with ND reached hypertensive levels (p < 0.01; compared with CONT). No changes in CVP and vascular reactivity were observed in both experimental groups. We conclude that high doses of ND elicit cardiotoxic effects with cardiac remodelling and injury. Cardiac changes reduce the BJR sensitivity. Together, these abnormalities contributed to the development of hypertension in animals in the DECA group. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Still a role for surgery as first-line therapy of splenic marginal zone lymphoma? Results of a prospective observational study.

    PubMed

    Pata, Giacomo; Bartoli, Michele; Damiani, Enrico; Solari, Stefano; Anastasia, Antonella; Pagani, Chiara; Tucci, Alessandra

    2017-05-01

    Assessment of hematologic improvement, survival and peri-operative morbidity after first-line splenectomy for splenic marginal zone lymphoma (SMZL). Forty-three patients undergoing open splenectomy were prospectively analyzed. Perioperative clinical course, overall and progression-free survival (OS-PFS) were evaluated. Risk factors analyzed were gender, age, ASA-grade, ECOG performance status, presence of B-symptoms, body mass index, steroidal treatment, serum albumin concentration, IIL-score, operative time, spleen size and weight. The median follow-up was 31 months (IQR 15-76; range 24-154). Anemia and thrombocytopenia resolved in 80% of patients at 6 months; in 60% at 2 years. The 5-year and 10-year PFS were 35% and 13% respectively, with a median of 35 months (shorter in patients with ECOG performance status ≥2 and B-symptoms). Nineteen cases (44.2%) had a progression of disease within 2 years. Of these, 14 (32.6%) received adjuvant chemotherapy (mainly R-FC or R-CVP). Progression was attributed to high-grade B lymphoma in 7 (16.3%) patients. The median time between diagnosis and progression to aggressive lymphoma was 25.5 months (range 18.8-81.8). The median time to next treatment was 83.5 months (95% CI 49-118). The 5-year and 10-year OS were 75% and 53% respectively. Mortality was due to disease progression and histological transformation in high-grade B lymphoma in 50% of cases, myelodisplastic syndrome in 15%, recurrence of hemolytic anemia in 15%, Hodgkin lymphoma in 7% and to infections (mainly pulmonary) in the remaining 13% of cases. Post-operative morbidity was 2.3% (1 patient with grade-3 complication). Overall grade ≥2 complication rate was 32.5% (mainly hemorrhagic and pulmonary complications). Spleen weight was the only independent risk factor for morbidity. Mortality was nil. Splenectomy is safe and effective as regards cytopenia resolution and OS, although disease progression is frequently observed at follow-up. Such results are strictly linked to accurate pre- and post-operative clinical management and optimal anesthesiologic approach. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  8. Path planning during combustion mode switch

    DOEpatents

    Jiang, Li; Ravi, Nikhil

    2015-12-29

    Systems and methods are provided for transitioning between a first combustion mode and a second combustion mode in an internal combustion engine. A current operating point of the engine is identified and a target operating point for the internal combustion engine in the second combustion mode is also determined. A predefined optimized transition operating point is selected from memory. While operating in the first combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion engine to approach the selected optimized transition operating point. When the engine is operating at the selected optimized transition operating point, the combustion mode is switched from the first combustion mode to the second combustion mode. While operating in the second combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion to approach the target operating point.

  9. 75 FR 44942 - 2015 Resource Pool-Sierra Nevada Customer Service Region

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-30

    ...The Western Area Power Administration (Western), a Federal power marketing administration of the Department of Energy (DOE), published its 2004 Power Marketing Plan (Marketing Plan) for the Sierra Nevada Customer Service Region (SNR) in the Federal Register on June 25, 1999. The Marketing Plan specifies the terms and conditions under which Western will market power from the Central Valley Project (CVP) and the Washoe Project beginning January 1, 2005, and continuing through December 31, 2024. The Marketing Plan provided for a portion of SNR's resources to be reallocated through a 2015 Resource Pool. On June 3, 2009, Western published a Call for 2015 Resource Pool Applications. On September 28, 2009, Western published a Notice of Extension to file applications. This notice announces Western's proposed allocations of power from the 2015 Resource Pool.

  10. Gastric and colonic mantle cell lymphoma - incidental discovery.

    PubMed

    Pitigoi, Dan; Stoica, Victor; Stoia, Razvan; Dobrea, Camelia; Becheanu, Gabriel; Diculescu, Mircea

    2009-03-01

    A 65-year old patient, with no medical history, was admitted for lower gastrointestinal bleeding. On clinical examination the patient seemed to be in good health. However the examination was completed with a rectosigmoidoscopy revealing the presence of mucosal erosions, ulcerations, multiple papulae. The histopathological examination raised the suspicion of a colonic lymphoma. Gastric biopsies suggested a gastric MALT type lymphoma associated to the colonic lymphoma, but the immunohistochemical profile corresponded to a mantle cell lymphoma. In spite of the general poor prognosis of mantle cell lymphoma, our patient had a good clinical and endoscopic response to the standard cyclophosphamide, vincristine, prednisone (CVP) therapy. The cases of gastric and colonic mantle lymphoma are rare, the response to therapy is poor; fortunately, our patient had a complete resolution after completion of the six cycles of chemotherapy.

  11. 75 FR 3856 - Drawbridge Operation Regulations; Great Egg Harbor Bay, Between Beesleys Point and Somers Point, NJ

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-25

    ...-AA09 Drawbridge Operation Regulations; Great Egg Harbor Bay, Between Beesleys Point and Somers Point... that govern the operation of the US Route 9/Beesleys Point Bridge over Great Egg Harbor Bay, at mile 3... Operation Regulations; Great Egg Harbor Bay, between Beesleys Point and Somers Point, NJ, in the Federal...

  12. Immediate effects of different schedules of somatostatin on portal pressure in patients with liver cirrhosis.

    PubMed

    Zhang, C; Xu, J-M; Kong, D-R; Min, X-K; Chen, R

    2013-06-01

    Somatostatin (SST) is used for the treatment of acute variceal bleeding based on its ability to decrease portal pressure and collateral blood flow. To date, no studies have focused on the immediate-early effects (between 1 and 30 min) of SST. The aim of this study was to compare the efficacy of different schedules of SST therapy with placebo on portal pressure in patients with portal hypertension treated with portal-azygous disconnection and to test whether an increase in bolus or infusion dose can improve the clinical efficacy of SST therapy.   Patients were treated with four different schedules: (a) standard dose (n = 11): one 250 μg bolus + a continuous infusion of 250 μg/h; (b) medium dose (n = 10): 500 μg bolus + a continuous infusion of 250 μg/h; (c) high dose (n = 10): 250 μg bolus + a continuous infusion of 500 μg/h; (d) control (n = 10): an injection of placebo (saline) followed by a placebo infusion. Following SST or placebo administration, portal pressure, central venous pressure (CVP), systemic blood pressure and heart rate (HR) were measured at 1, 3, 5, 7, 10 and 30 min.   The three schedules of SST induced a marked, rapid and highly significant decrease in portal pressure. The decline in portal pressure was moderate at 1 min (P < 0·040), achieved a peak effect at 5 min (P < 0·009) and remained decreased at 30 min. The effect of SST on portal pressure was significantly greater than placebo from 1 min after administration. There were no significant differences in portal pressure decrease between the three schedules of SST. The three schedules of SST and the placebo schedule did not induce significant changes in HR, systemic blood pressure and CVP.   This study shows that SST is effective in decreasing portal pressure within 30 min of administration in patients with liver cirrhosis. The clinical schedule used in this study was reasonable and safe. © 2013 Blackwell Publishing Ltd.

  13. Climate Change Impact Study with CMIP5 and Comparison with CMIP3

    NASA Astrophysics Data System (ADS)

    Wang, J.; Yin, H.; Reyes, E.; Chung, F. I.

    2016-12-01

    One of significant uncertainties in climate change impact study is the selection of climate model projection including the choosing of greenhouse gas emission scenarios. With the new generation of climate model projection, CMIP5, coming into use, CCTAG selected 11 climate models and two RCPs (rcp4.5 and rcp8.5) for California. Previous DWR climate change study was based on 6 CMIP3 climate models and two emission scenarios (SRES A2 and B1) which were selected by CAT. It is an unanswered question that how the selection of these climate model projections and emission scenarios affect the assessment of climate change impact on future water supply of California CVP/SWP project. This work will run the water planning model CalSim in DWR with 44 CMIP5 and 12 CMIP3 climate model projections to investigate the sensitivity of climate model impact study on future water supply in the CVP/SWP region to the section of climate model projection. It was found that in 2060 CMIP5 projects the wetting trend in Northern California while CMIP3 projects the drying trend in the entire California on the average. And CMIP5 projects about half-degree more warming than CMIP3. As a result, Sacramento River rim inflow increases by 8% for CMIP5 and reduces by 3% for CMIP3. In spite of this difference in rim inflow, north of Delta carryover storage will be reduced both under CMIP5 (14%) and under CMIP3 (23%) in 2060. And south Delta export will be reduced both for CMIP5 (8%) and for CMIP3 (15%). Thus, The CC impact uncertainty caused by the selection of climate model projection (CMIP3 vs CMIP5) is about 7% in terms of Delta export and about 9% in terms of north of Delta carryover storage. This uncertainty is more than the one caused by the selection of sea level rise in that the climate change impact uncertainty caused by the selection of sea level rise (Zero vs 1.5ft SLR) is about 5% in terms of Delta export and about 4-5% in terms of North of Delta carryover storage.

  14. 24 CFR 902.47 - Management operations portion of total PHAS points.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Management operations portion of... Operations § 902.47 Management operations portion of total PHAS points. Of the total 100 points available for a PHAS score, a PHA may receive up to 30 points based on the Management Operations Indicator. ...

  15. ASCO 2017 meeting summary: updates to practice-changing studies in untreated non-Hodgkin lymphoma

    PubMed Central

    Laneuville, P.; Larouche, J.F.; Tosikyan, A.; Christofides, A.

    2017-01-01

    The 2017 annual meeting of the American Society of Clinical Oncology took place in Chicago, Illinois, 2–6 June. At the meeting, results from key studies in the first-line treatment of indolent non-Hodgkin lymphoma (inhl) were presented. Of those studies, two were selected for oral presentations: 9-year follow-up data from the stil nhl1 trial, which compared the efficacy and safety of bendamustine plus rituximab (br) with those of rituximab plus cyclophosphamide–vincristine–prednisone–doxorubicin (r-chop); and 5-year follow-up data from the bright study, which compared br with r-chop and r-cvp (rituximab plus cyclophosphamide–vincristine–prednisone) combined. Our meeting report describes the foregoing studies and includes interviews with key investigators, plus commentaries from three Quebec hematologists on the potential effects for Canadian practice.

  16. [Analysis of financial statements of Japanese private hospitals (1982-1991)].

    PubMed

    Matsuda, S; Murata, H

    1996-06-01

    In order to clarify the financial situation of Japanese private hospitals, the financial statements provided by the Social Welfare and Medical Service Corporation were analyzed for the period from 1982 to 1991. The results clarified the low growth rate and low profitability of the Japanese private hospitals, although their financial situation was relatively stable. However, the efficiency of cost has been stalled in recent years and profitability has been declining due to the low turnover rate of capital. According to the CVP analysis, the Profit volume ratio of the investigated hospitals has been increased to the level of 95%. This situation means that, in the current financial situation, more than half of the Japanese private hospitals will go into the red if revenue declines 5% due to some short term change in the managerial environment.

  17. [Diagnosis and surgical treatment of Castleman's disease].

    PubMed

    Ma, Shi-hong; Liu, Qin-jiang; Zhang, You-cheng; Yang, Rong

    2011-04-26

    To explore the clinical features and surgical treatment of tumors associated with Castleman's disease (CD). The clinical profiles of 19 patients with neck giant lymph node hyperplasia were analyzed retrospectively. There were 8 males and 11 females with a median age of 40 years old (range: 7 - 74). The tumor locations were neck (n = 12), neck & mediastinal cavity (n = 2), axillary fossa (n = 2), retroperitoneal area (n = 2) and abdominal cavity (n = 1). Eighteen of them underwent surgical resection of tumor or lymph nodes. All were diagnosed as CD by pathological examinations. There were 16 localized CD (LCD) including hyaline vascular type (HV type, n = 11), mixed type (mix type, n = 4) and plasma cell type-Hodgkin's disease (n = 1). Among 3 multicentric CD (MCD), there were 2 case of plasma cell type (PC type) and 1 case of mixed type (mix type). Long-term survival was achieved in 19 cases among which 1 case of plasma cell type MCD survived for 5 years and underwent a second operation and postoperative chemotherapy of CVP (cyclophosphamide, vincristine & prednisone) regimen for 3 cycles due to recurrence in 2 years and 1 case of plasma cell type LCD-Hodgkin's disease survived for 15 months and underwent a second operation and postoperative chemotherapy of ABVD (adriamycin, bleomycin, vinblastine & dacarbazine)regimen for 6 cycles due to recurrence in 6 months. One case of plasma cell type MCD in abdominal cavity on chemotherapy of CHOP (cyclophosphamide, hydroxydaunorubicin, vincristine & prednisone) regimen for 6 cycles was discharged after a successful management of intestinal obstruction. The major clinical symptom of CD is a gradually enlarging painless mass. Surgical resection of tumor remains the first-line treatment for localized CD and the prognosis is excellent. Multicentric and plasma cell type CDs are prone to recurrence and transformation to lymphoma. And their first-line therapeutic should encompass multi-modality regimens of surgery and adjuvant chemotherapy. However, the clinical prognosis is still poor.

  18. 78 FR 23845 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, mile 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate the Smith Point...

  19. Providing nearest neighbor point-to-point communications among compute nodes of an operational group in a global combining network of a parallel computer

    DOEpatents

    Archer, Charles J.; Faraj, Ahmad A.; Inglett, Todd A.; Ratterman, Joseph D.

    2012-10-23

    Methods, apparatus, and products are disclosed for providing nearest neighbor point-to-point communications among compute nodes of an operational group in a global combining network of a parallel computer, each compute node connected to each adjacent compute node in the global combining network through a link, that include: identifying each link in the global combining network for each compute node of the operational group; designating one of a plurality of point-to-point class routing identifiers for each link such that no compute node in the operational group is connected to two adjacent compute nodes in the operational group with links designated for the same class routing identifiers; and configuring each compute node of the operational group for point-to-point communications with each adjacent compute node in the global combining network through the link between that compute node and that adjacent compute node using that link's designated class routing identifier.

  20. Extravasation from venous catheter: a serious complication potentially missed by lung imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spicer, K.M.; Gordon, L.

    Three patients were referred for lung ventiliation and perfusion (V/Q) imaging with symptoms strongly suggestive of pulmonary embolus (PE). Chest roentgenograms and xenon ventilation studies on all three were normal, save for prominent mediastinal silhouettes and effusions. Technetium-99m macroaggregated albumin(Tc-99m MAA), when injected through the central venous catheter (CVP), revealed mediastinal localization, whereas antecubital injections showed normal pulmonary perfusion. Contrast fluoroscopy introduced through the venous catheter in the first patient defined the extravasation. For patients under strong suspicion of PE, with a venous catheter whose distal tip is seen about the level of the heart on chest radiograph, the authorsmore » recommend administering the perfusion agent slowly through the central catheter to exclude catheter-induced complications. When extravasation is detected, injection of Tc-99m MAA by peripheral vein should be used to exclude PE.« less

  1. Direct Numerical Simulation of a Coolant Jet in a Periodic Crossflow

    NASA Technical Reports Server (NTRS)

    Sharma, Chirdeep; Acharya, Sumanta

    1998-01-01

    A Direct Numerical Simulation of a coolant jet injected normally into a periodic crossflow is presented. The physical situation simulated represents a periodic module in a coolant hole array with a heated crossflow. A collocated finite difference scheme is used which is fifth-order accurate spatially and second-order accurate temporally. The scheme is based on a fractional step approach and requires the solution of a pressure-Poisson equation. The simulations are obtained for a blowing ratio of 0.25 and a channel Reynolds number of 5600. The simulations reveal the dynamics of several large scale structures including the Counter-rotating Vortex Pair (CVP), the horse-shoe vortex, the shear layer vortex, the wall vortex and the wake vortex. The origins and the interactions of these vortical structures are identified and explored. Also presented are the turbulence statistics and how they relate to the flow structures.

  2. [Total-body irradiation in non-Hodgkin's lymphomas as an alternative to chemotherapy].

    PubMed

    Rühl, U

    1977-05-01

    On the bases of previous experiences and present results it can be stated that total-body irradiation is an effective therapeutical technique for treatment of lymphocytic non-Hodkin's lymphomas including chronic lymphatic leukemia; first results from prospectively randomized studies even revealed a slight superiority of this method as compared to the scheme of combined cytostatical therapy (CVP) mostly applied at present. Particular advantages of total-body irradiation are the easy applicability, the relatively short time needed for treatment, and the lack of subjective secondary effects. Thus, ambulatory therapy can be performed without any difficulty. The only complication which may occur arises from myelotoxicity reaching its maximum not earlier than after the end of treatment. Careful follow-up of the patients, therefore, is indispensable. The indication of total-body irradiation for the treatment of non-Hodgkin's lymphomas depends on the objective findings, the stage of disease, and mainly on the histological classification.

  3. [The impacts of low-dose corticosteroids infusion given in different manners on refractory septic shock patients].

    PubMed

    Chen, Zhi; Yang, Chunli; He, Huiwei; He, Zhaohui

    2015-06-01

    To discuss the influence of different ways of low-dose corticosteroids infusion on hemodynamics, changes in blood glucose level and prognosis in patients with refractory septic shock. A prospective single-blind randomized controlled trial was conducted. Refractory septic shock patients admitted to the Department of Critical Care Medicine of Jiangxi Provincial People's Hospital from April 1st, 2013 to October 31st, 2014 were enrolled for the study. The patients were divided into control group and research group by random number table. Besides conventional treatment for septic shock, patients in control group were given 200 mg/d hydrocortisone intravenous infusion lasting for 2 hours, while those of research group were given 8.33 mg/h hydrocortisone per hour with an intravenous pump. Treatment lasted for 5 continuous days for both groups. The changes in heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP) and arterial blood lactic acid in both groups were observed at the time of enroldment and 6 hours, 24 hours, 48 hours, and 5 days after the treatment. With a dynamic blood glucose monitor, mean blood glucose (MBG) level, largest amplitude of glycemic excursions (LAGE), glucose variability (GV), and the ratio of hyperglycaemia time were recorded. The duration of shock, length of intensive care unit (ICU) stay, total length of hospital stay, and 28-day mortality of both groups were recorded. Seventy-nine septic shock patients were assigned to the treatment, with 41 in control group, and 38 in research group. Compared with control group, 6-hour MAP in research group was obviously lowered [mmHg (1 mmHg=0.133 kPa): 66.31±4.38 vs. 68.58±4.86, t=1.062, P=0.033], but there were no significant differences in HR, MAP, CVP, lactic acid clearance and norepinephrine (NE) utilization rates at other time points between two groups. No significant difference in MBG was found between research group and control group (mmol/L: 8.69±2.14 vs. 9.95±3.87, t=1.771, P=0.080), but LAGE, GV, the ratio of hyperglycemia time in research group were significantly lower than those of the control group [LAGE (mmol/L): 17.18±8.97 vs. 22.71±11.80, t=2.331, P=0.022; GV (mmol/L): 2.57±1.05 vs. 3.16±1.37, t=2.136, P=0.036; the ratio of hyperglycemia time: (43.1±11.7)% vs. (49.4±15.3)%, t=2.044, P=0.044]. There was no statistical difference in the following features between research group and control group, such as the duration of shock (days: 3.47±0.98 vs. 3.61±1.07, t=0.605, P=0.547), length of ICU stay (days: 8.74±3.12 vs. 9.97±3.37, t=1.543, P=0.120), total length of hospital stay (days: 18.34±9.27 vs. 19.58±9.83, t=0.576, P=0.566) and 28-day mortality rate (23.68% vs. 26.83%, χ2=0.103, P=0.748). Compared with slow intravenous infusion, a continuous intravenous supplementation of small amount of hydrocortisone to patients with refractory septic shock could stabilize blood glucose levels and maintain metabolic balance efficiently. However, in both groups there was no significant difference in the efficiency in stabilizing hemodynamics, shortening shock duration, reducing ICU or hospital days and decreasing 28-day mortality.

  4. 76 FR 60733 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate bridge...

  5. Operating Point Self-Regulator for Giant Magneto-Impedance Magnetic Sensor.

    PubMed

    Zhou, Han; Pan, Zhongming; Zhang, Dasha

    2017-05-11

    The giant magneto-impedance (GMI) magnetic sensor based on the amorphous wire has been believed to be tiny dimensions, high sensitivity, quick response, and small power consumption. This kind of sensor is usually working under a bias magnetic field that is called the sensor's operating point. However, the changes in direction and intensity of the external magnetic field, or the changes in sensing direction and position of the sensor, will lead to fluctuations in operating point when the sensor is working without any magnetic shield. In this work, a GMI sensor based on the operating point self-regulator is designed to overcome the problem. The regulator is based on the compensated feedback control that can maintain the operating point of a GMI sensor in a uniform position. With the regulator, the GMI sensor exhibits a stable sensitivity regardless of the external magnetic field. In comparison with the former work, the developed operating point regulator can improve the accuracy and stability of the operating point and therefore decrease the noise and disturbances that are introduced into the GMI sensor by the previous self-regulation system.

  6. Operating Point Self-Regulator for Giant Magneto-Impedance Magnetic Sensor

    PubMed Central

    Zhou, Han; Pan, Zhongming; Zhang, Dasha

    2017-01-01

    The giant magneto-impedance (GMI) magnetic sensor based on the amorphous wire has been believed to be tiny dimensions, high sensitivity, quick response, and small power consumption. This kind of sensor is usually working under a bias magnetic field that is called the sensor’s operating point. However, the changes in direction and intensity of the external magnetic field, or the changes in sensing direction and position of the sensor, will lead to fluctuations in operating point when the sensor is working without any magnetic shield. In this work, a GMI sensor based on the operating point self-regulator is designed to overcome the problem. The regulator is based on the compensated feedback control that can maintain the operating point of a GMI sensor in a uniform position. With the regulator, the GMI sensor exhibits a stable sensitivity regardless of the external magnetic field. In comparison with the former work, the developed operating point regulator can improve the accuracy and stability of the operating point and therefore decrease the noise and disturbances that are introduced into the GMI sensor by the previous self-regulation system. PMID:28492514

  7. Stabilizing operation point technique based on the tunable distributed feedback laser for interferometric sensors

    NASA Astrophysics Data System (ADS)

    Mao, Xuefeng; Zhou, Xinlei; Yu, Qingxu

    2016-02-01

    We describe a stabilizing operation point technique based on the tunable Distributed Feedback (DFB) laser for quadrature demodulation of interferometric sensors. By introducing automatic lock quadrature point and wavelength periodically tuning compensation into an interferometric system, the operation point of interferometric system is stabilized when the system suffers various environmental perturbations. To demonstrate the feasibility of this stabilizing operation point technique, experiments have been performed using a tunable-DFB-laser as light source to interrogate an extrinsic Fabry-Perot interferometric vibration sensor and a diaphragm-based acoustic sensor. Experimental results show that good tracing of Q-point was effectively realized.

  8. 47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...

  9. 47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...

  10. 47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...

  11. 47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...

  12. 47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...

  13. International Space Station Payload Operations Integration

    NASA Technical Reports Server (NTRS)

    Fanske, Elizabeth Anne

    2011-01-01

    The Payload Operations Integrator (POINT) plays an integral part in the Certification of Flight Readiness process for the Mission Operations Laboratory and the Payload Operations Integration Function that supports International Space Station Payload operations. The POINTs operate in support of the POIF Payload Operations Manager to bring together and integrate the Certification of Flight Readiness inputs from various MOL teams through maintaining an open work tracking log. The POINTs create monthly metrics for current and future payloads that the Payload Operations Integration Function supports. With these tools, the POINTs assemble the Certification of Flight Readiness package before a given flight, stating that the Mission Operations Laboratory is prepared to support it. I have prepared metrics for Increment 29/30, maintained the Open Work Tracking Logs for Flights ULF6 (STS-134) and ULF7 (STS-135), and submitted the Mission Operations Laboratory Certification of Flight Readiness package for Flight 44P to the Mission Operations Directorate (MOD/OZ).

  14. Physical constraints, fundamental limits, and optimal locus of operating points for an inverted pendulum based actuated dynamic walker.

    PubMed

    Patnaik, Lalit; Umanand, Loganathan

    2015-10-26

    The inverted pendulum is a popular model for describing bipedal dynamic walking. The operating point of the walker can be specified by the combination of initial mid-stance velocity (v0) and step angle (φm) chosen for a given walk. In this paper, using basic mechanics, a framework of physical constraints that limit the choice of operating points is proposed. The constraint lines thus obtained delimit the allowable region of operation of the walker in the v0-φm plane. A given average forward velocity vx,avg can be achieved by several combinations of v0 and φm. Only one of these combinations results in the minimum mechanical power consumption and can be considered the optimum operating point for the given vx,avg. This paper proposes a method for obtaining this optimal operating point based on tangency of the power and velocity contours. Putting together all such operating points for various vx,avg, a family of optimum operating points, called the optimal locus, is obtained. For the energy loss and internal energy models chosen, the optimal locus obtained has a largely constant step angle with increasing speed but tapers off at non-dimensional speeds close to unity.

  15. The influence of transducer operating point on distortion generation in the cochlea

    NASA Astrophysics Data System (ADS)

    Sirjani, Davud B.; Salt, Alec N.; Gill, Ruth M.; Hale, Shane A.

    2004-03-01

    Distortion generated by the cochlea can provide a valuable indicator of its functional state. In the present study, the dependence of distortion on the operating point of the cochlear transducer and its relevance to endolymph volume disturbances has been investigated. Calculations have suggested that as the operating point moves away from zero, second harmonic distortion would increase. Cochlear microphonic waveforms were analyzed to derive the cochlear transducer operating point and to quantify harmonic distortions. Changes in operating point and distortion were measured during endolymph manipulations that included 200-Hz tone exposures at 115-dB SPL, injections of artificial endolymph into scala media at 80, 200, or 400 nl/min, and treatment with furosemide given intravenously or locally into the cochlea. Results were compared with other functional changes that included action potential thresholds at 2.8 or 8 kHz, summating potential, endocochlear potential, and the 2 f1-f2 and f2-f1 acoustic emissions. The results demonstrated that volume disturbances caused changes in the operating point that resulted in predictable changes in distortion. Understanding the factors influencing operating point is important in the interpretation of distortion measurements and may lead to tests that can detect abnormal endolymph volume states.

  16. 75 FR 3497 - Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point 2, LLC, Entergy Nuclear Indian...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-21

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247 and 50-286; NRC-2010-0006] Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point 2, LLC, Entergy Nuclear Indian Point 3, LLC,: Indian Point Nuclear Generating Unit Nos. 2 and 3; Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity To Request a...

  17. Purely Singular Continuous Spectrum for CMV Operators Generated by Subshifts

    NASA Astrophysics Data System (ADS)

    Ong, Darren C.

    2014-03-01

    We prove uniform absence of point spectrum for CMV operators corresponding to the period doubling subshift. We also prove almost sure absence of point spectrum for CMV operators corresponding to a class of Sturmian subshifts. Lastly, we prove almost sure absence of point spectrum for CMV operators corresponding to some subshifts generated by a coding of a rotation.

  18. Comparison of two stand-alone CADe systems at multiple operating points

    NASA Astrophysics Data System (ADS)

    Sahiner, Berkman; Chen, Weijie; Pezeshk, Aria; Petrick, Nicholas

    2015-03-01

    Computer-aided detection (CADe) systems are typically designed to work at a given operating point: The device displays a mark if and only if the level of suspiciousness of a region of interest is above a fixed threshold. To compare the standalone performances of two systems, one approach is to select the parameters of the systems to yield a target false-positive rate that defines the operating point, and to compare the sensitivities at that operating point. Increasingly, CADe developers offer multiple operating points, which necessitates the comparison of two CADe systems involving multiple comparisons. To control the Type I error, multiple-comparison correction is needed for keeping the family-wise error rate (FWER) less than a given alpha-level. The sensitivities of a single modality at different operating points are correlated. In addition, the sensitivities of the two modalities at the same or different operating points are also likely to be correlated. It has been shown in the literature that when test statistics are correlated, well-known methods for controlling the FWER are conservative. In this study, we compared the FWER and power of three methods, namely the Bonferroni, step-up, and adjusted step-up methods in comparing the sensitivities of two CADe systems at multiple operating points, where the adjusted step-up method uses the estimated correlations. Our results indicate that the adjusted step-up method has a substantial advantage over other the two methods both in terms of the FWER and power.

  19. Automated design of image operators that detect interest points.

    PubMed

    Trujillo, Leonardo; Olague, Gustavo

    2008-01-01

    This work describes how evolutionary computation can be used to synthesize low-level image operators that detect interesting points on digital images. Interest point detection is an essential part of many modern computer vision systems that solve tasks such as object recognition, stereo correspondence, and image indexing, to name but a few. The design of the specialized operators is posed as an optimization/search problem that is solved with genetic programming (GP), a strategy still mostly unexplored by the computer vision community. The proposed approach automatically synthesizes operators that are competitive with state-of-the-art designs, taking into account an operator's geometric stability and the global separability of detected points during fitness evaluation. The GP search space is defined using simple primitive operations that are commonly found in point detectors proposed by the vision community. The experiments described in this paper extend previous results (Trujillo and Olague, 2006a,b) by presenting 15 new operators that were synthesized through the GP-based search. Some of the synthesized operators can be regarded as improved manmade designs because they employ well-known image processing techniques and achieve highly competitive performance. On the other hand, since the GP search also generates what can be considered as unconventional operators for point detection, these results provide a new perspective to feature extraction research.

  20. 30 CFR 250.1000 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operator must, if practical, durably mark all of its above-water transfer points by April 14, 1999 or the... transfer point, and the transfer point is located above water, then the operator must identify the transfer point on a schematic located on the facility. (iii) If a transfer point is located below water, then the...

  1. 47 CFR 101.107 - Frequency tolerance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... to private operational fixed point-to-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave systems, with a channel greater than or equal to 50 KHz bandwidth...

  2. 49 CFR 236.303 - Control circuits for signals, selection through circuit controller operated by switch points or...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... circuit controller operated by switch points or by switch locking mechanism. 236.303 Section 236.303... § 236.303 Control circuits for signals, selection through circuit controller operated by switch points or by switch locking mechanism. The control circuit for each aspect with indication more favorable...

  3. 49 CFR 236.303 - Control circuits for signals, selection through circuit controller operated by switch points or...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... circuit controller operated by switch points or by switch locking mechanism. 236.303 Section 236.303... § 236.303 Control circuits for signals, selection through circuit controller operated by switch points or by switch locking mechanism. The control circuit for each aspect with indication more favorable...

  4. 49 CFR 236.303 - Control circuits for signals, selection through circuit controller operated by switch points or...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... circuit controller operated by switch points or by switch locking mechanism. 236.303 Section 236.303... § 236.303 Control circuits for signals, selection through circuit controller operated by switch points or by switch locking mechanism. The control circuit for each aspect with indication more favorable...

  5. 49 CFR 236.303 - Control circuits for signals, selection through circuit controller operated by switch points or...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... circuit controller operated by switch points or by switch locking mechanism. 236.303 Section 236.303... § 236.303 Control circuits for signals, selection through circuit controller operated by switch points or by switch locking mechanism. The control circuit for each aspect with indication more favorable...

  6. 49 CFR 236.303 - Control circuits for signals, selection through circuit controller operated by switch points or...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... circuit controller operated by switch points or by switch locking mechanism. 236.303 Section 236.303... § 236.303 Control circuits for signals, selection through circuit controller operated by switch points or by switch locking mechanism. The control circuit for each aspect with indication more favorable...

  7. 78 FR 58570 - Environmental Assessment; Entergy Nuclear Operations, Inc., Big Rock Point

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ... Assessment; Entergy Nuclear Operations, Inc., Big Rock Point AGENCY: Nuclear Regulatory Commission. ACTION... applicant or the licensee), for the Big Rock Point (BRP) Independent Spent Fuel Storage Installation (ISFSI... Rock Point (BRP) Independent Spent Fuel Storage Installation (ISFSI). II. Environmental Assessment (EA...

  8. Interest point detection for hyperspectral imagery

    NASA Astrophysics Data System (ADS)

    Dorado-Muñoz, Leidy P.; Vélez-Reyes, Miguel; Roysam, Badrinath; Mukherjee, Amit

    2009-05-01

    This paper presents an algorithm for automated extraction of interest points (IPs)in multispectral and hyperspectral images. Interest points are features of the image that capture information from its neighbours and they are distinctive and stable under transformations such as translation and rotation. Interest-point operators for monochromatic images were proposed more than a decade ago and have since been studied extensively. IPs have been applied to diverse problems in computer vision, including image matching, recognition, registration, 3D reconstruction, change detection, and content-based image retrieval. Interest points are helpful in data reduction, and reduce the computational burden of various algorithms (like registration, object detection, 3D reconstruction etc) by replacing an exhaustive search over the entire image domain by a probe into a concise set of highly informative points. An interest operator seeks out points in an image that are structurally distinct, invariant to imaging conditions, stable under geometric transformation, and interpretable which are good candidates for interest points. Our approach extends ideas from Lowe's keypoint operator that uses local extrema of Difference of Gaussian (DoG) operator at multiple scales to detect interest point in gray level images. The proposed approach extends Lowe's method by direct conversion of scalar operations such as scale-space generation, and extreme point detection into operations that take the vector nature of the image into consideration. Experimental results with RGB and hyperspectral images which demonstrate the potential of the method for this application and the potential improvements of a fully vectorial approach over band-by-band approaches described in the literature.

  9. Development of a large scale bipolar NiH2 battery

    NASA Technical Reports Server (NTRS)

    Adler, E.; Perez, F.

    1983-01-01

    The bipolar battery concept, developed in cooperation with NASA, is described in the context of the advantages afforded by near-term IPV and CVP cell technology. The projected performance, development requirements, and a possible approach to bipolar battery design are outlined. Consideration is given to packaging electrodes within a common hydrophobic plastic frame, electrode technology that involves a photochemically etched 0.1 mm thick nickel substrate coated with a 10 mg/sq cm mixture of platinum powder and TFE30, and an electrode design that eliminates the screen and doubles the electrode thickness (from the currently used 0.8 mm) while retaining the active material loading of 1.6-1.8 gm/cu cm. Also covered are thermal management, and electrolyte and oxygen management. It is concluded that a high voltage, high capacity, bipolar NiH2 cell can be configured with proper development for use in large power systems, and that it can provide considerable weight savings.

  10. Utilization of a cognitive task analysis for laparoscopic appendectomy to identify differentiated intraoperative teaching objectives.

    PubMed

    Smink, Douglas S; Peyre, Sarah E; Soybel, David I; Tavakkolizadeh, Ali; Vernon, Ashley H; Anastakis, Dimitri J

    2012-04-01

    Experts become automated when performing surgery, making it difficult to teach complex procedures to trainees. Cognitive task analysis (CTA) enables experts to articulate operative steps and cognitive decisions in complex procedures such as laparoscopic appendectomy, which can then be used to identify central teaching points. Three local surgeon experts in laparoscopic appendectomy were interviewed using critical decision method-based CTA methodology. Interview transcripts were analyzed, and a cognitive demands table (CDT) was created for each expert. The individual CDTs were reviewed by each expert for completeness and then combined into a master CDT. Percentage agreement on operative steps and decision points was calculated for each expert. The experts then participated in a consensus meeting to review the master CDT. Each surgeon expert was asked to identify in the master CDT the most important teaching objectives for junior-level and senior-level residents. The experts' responses for junior-level and senior-level residents were compared using a χ(2) test. The surgeon experts identified 24 operative steps and 27 decision points. Eighteen of the 24 operative steps (75%) were identified by all 3 surgeon experts. The percentage of operative steps identified was high for each surgeon expert (96% for surgeon 1, 79% for surgeon 2, and 83% for surgeon 3). Of the 27 decision points, only 5 (19%) were identified by all 3 surgeon experts. The percentage of decision points identified varied by surgeon expert (78% for surgeon 1, 59% for surgeon 2, and 48% for surgeon 3). When asked to identify key teaching points, the surgeon experts were more likely to identify operative steps for junior residents (9 operative steps and 6 decision points) and decision points for senior residents (4 operative steps and 13 decision points) (P < .01). CTA can deconstruct the essential operative steps and decision points associated with performing a laparoscopic appendectomy. These results provide a framework to identify key teaching principles to guide intraoperative instruction. These learning objectives could be used to guide resident level-appropriate teaching of an essential general surgery procedure. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. 47 CFR 22.325 - Control points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Control points. 22.325 Section 22.325... Operational and Technical Requirements Operational Requirements § 22.325 Control points. Each station in the Public Mobile Services must have at least one control point and a person on duty who is responsible for...

  12. 47 CFR 22.325 - Control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Control points. 22.325 Section 22.325... Operational and Technical Requirements Operational Requirements § 22.325 Control points. Each station in the Public Mobile Services must have at least one control point and a person on duty who is responsible for...

  13. 47 CFR 22.325 - Control points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Control points. 22.325 Section 22.325... Operational and Technical Requirements Operational Requirements § 22.325 Control points. Each station in the Public Mobile Services must have at least one control point and a person on duty who is responsible for...

  14. 47 CFR 22.325 - Control points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 2 2014-10-01 2014-10-01 false Control points. 22.325 Section 22.325... Operational and Technical Requirements Operational Requirements § 22.325 Control points. Each station in the Public Mobile Services must have at least one control point and a person on duty who is responsible for...

  15. 47 CFR 22.325 - Control points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Control points. 22.325 Section 22.325... Operational and Technical Requirements Operational Requirements § 22.325 Control points. Each station in the Public Mobile Services must have at least one control point and a person on duty who is responsible for...

  16. Fixation of operating point and measurement of turn on characteristics of IGBT F4-75R06W1E3

    NASA Astrophysics Data System (ADS)

    Haseena, A.; Subhash Joshi T., G.; George, Saly

    2018-05-01

    For the proficient operation of the Power electronic circuit, signal level performance of power electronic devices are very important. For getting good signal level characteristics, fixing operating point is very critical. Device deviates from the typical characteristics given in the datasheet due to the presence of stray components in the circuit lay out. Fixation of operating point of typical silicon IGBT and its turn on characteristics is discussed in this paper.

  17. 77 FR 70847 - Entergy Nuclear Indian Point 2, LLC; Entergy Nuclear Operations, Inc., Indian Point Nuclear...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-27

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-247; NRC-2012-0284] Entergy Nuclear Indian Point 2, LLC; Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Unit No. 2, Request for Action AGENCY: Nuclear Regulatory Commission. ACTION: Request for Action; receipt. SUMMARY: The U.S. Nuclear...

  18. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  19. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  20. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  1. 49 CFR 236.738 - Detector, point.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Detector, point. 236.738 Section 236.738 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Detector, point. A circuit controller which is part of the switch operating mechanism and operated by a rod...

  2. 49 CFR 236.738 - Detector, point.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Detector, point. 236.738 Section 236.738 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Detector, point. A circuit controller which is part of the switch operating mechanism and operated by a rod...

  3. 49 CFR 236.738 - Detector, point.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Detector, point. 236.738 Section 236.738 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Detector, point. A circuit controller which is part of the switch operating mechanism and operated by a rod...

  4. 49 CFR 236.738 - Detector, point.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Detector, point. 236.738 Section 236.738 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Detector, point. A circuit controller which is part of the switch operating mechanism and operated by a rod...

  5. 49 CFR 236.738 - Detector, point.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Detector, point. 236.738 Section 236.738 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Detector, point. A circuit controller which is part of the switch operating mechanism and operated by a rod...

  6. Parallel point-multiplication architecture using combined group operations for high-speed cryptographic applications

    PubMed Central

    Saeedi, Ehsan; Kong, Yinan

    2017-01-01

    In this paper, we propose a novel parallel architecture for fast hardware implementation of elliptic curve point multiplication (ECPM), which is the key operation of an elliptic curve cryptography processor. The point multiplication over binary fields is synthesized on both FPGA and ASIC technology by designing fast elliptic curve group operations in Jacobian projective coordinates. A novel combined point doubling and point addition (PDPA) architecture is proposed for group operations to achieve high speed and low hardware requirements for ECPM. It has been implemented over the binary field which is recommended by the National Institute of Standards and Technology (NIST). The proposed ECPM supports two Koblitz and random curves for the key sizes 233 and 163 bits. For group operations, a finite-field arithmetic operation, e.g. multiplication, is designed on a polynomial basis. The delay of a 233-bit point multiplication is only 3.05 and 3.56 μs, in a Xilinx Virtex-7 FPGA, for Koblitz and random curves, respectively, and 0.81 μs in an ASIC 65-nm technology, which are the fastest hardware implementation results reported in the literature to date. In addition, a 163-bit point multiplication is also implemented in FPGA and ASIC for fair comparison which takes around 0.33 and 0.46 μs, respectively. The area-time product of the proposed point multiplication is very low compared to similar designs. The performance (1Area×Time=1AT) and Area × Time × Energy (ATE) product of the proposed design are far better than the most significant studies found in the literature. PMID:28459831

  7. Parallel point-multiplication architecture using combined group operations for high-speed cryptographic applications.

    PubMed

    Hossain, Md Selim; Saeedi, Ehsan; Kong, Yinan

    2017-01-01

    In this paper, we propose a novel parallel architecture for fast hardware implementation of elliptic curve point multiplication (ECPM), which is the key operation of an elliptic curve cryptography processor. The point multiplication over binary fields is synthesized on both FPGA and ASIC technology by designing fast elliptic curve group operations in Jacobian projective coordinates. A novel combined point doubling and point addition (PDPA) architecture is proposed for group operations to achieve high speed and low hardware requirements for ECPM. It has been implemented over the binary field which is recommended by the National Institute of Standards and Technology (NIST). The proposed ECPM supports two Koblitz and random curves for the key sizes 233 and 163 bits. For group operations, a finite-field arithmetic operation, e.g. multiplication, is designed on a polynomial basis. The delay of a 233-bit point multiplication is only 3.05 and 3.56 μs, in a Xilinx Virtex-7 FPGA, for Koblitz and random curves, respectively, and 0.81 μs in an ASIC 65-nm technology, which are the fastest hardware implementation results reported in the literature to date. In addition, a 163-bit point multiplication is also implemented in FPGA and ASIC for fair comparison which takes around 0.33 and 0.46 μs, respectively. The area-time product of the proposed point multiplication is very low compared to similar designs. The performance ([Formula: see text]) and Area × Time × Energy (ATE) product of the proposed design are far better than the most significant studies found in the literature.

  8. Energy harvesting influences electrochemical performance of microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Xin; Ren, Zhiyong Jason

    2017-07-01

    Microbial fuel cells (MFCs) can be effective power sources for remote sensing, wastewater treatment and environmental remediation, but their performance needs significant improvement. This study systematically analyzes how active harvesting using electrical circuits increased MFC system outputs as compared to passive resistors not only in the traditional maximal power point (MPP) but also in other desired operating points such as the maximum current point (MCP) and the maximum voltage point (MVP). Results show that active harvesting in MPP increased power output by 81-375% and active harvesting in MCP increased Coulombic efficiency by 207-805% compared with resisters operated at the same points. The cyclic voltammograms revealed redox potential shifts and supported the performance data. The findings demonstrate that active harvesting is a very effective approach to improve MFC performance across different operating points.

  9. Fuel freeze-point investigations. Final report, September 1982-March 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desmarais, L.A.; Tolle, F.F.

    1984-07-01

    The objective of this program was to conduct a detailed assessment of the low-temperature environment to which USAF aircraft are exposed for the purpose of defining a maximum acceptable fuel freeze-point and also to define any operational changes required with the use of a high freeze-point fuel. A previous study of B-52, C-141, and KC-135 operational missions indicated that the -58 C freeze point specification was too conservative. Based on recommendations resulting from the previous program, several improvements in the method of analysis were made, such as: expansion of the atmospheric temperature data base, the addition of ground temperature analysis,more » the addition of fuel-freezing analysis to the one-dimensional fuel-temperature computer program, and the examination of heat transfer in external fuel tanks, such as pylon or tip tanks. The B-52, C-141, and KC-135 mission were analyzed again, along with the operational missions of two tactical airplanes, the A-10 and F-15; -50C was determined to be the maximum allowable freeze point for a general-purpose USAF aviation turbine fuel. Higher freeze points can be tolerated if the probability of operational interference is acceptably low or if operational changes can be made. Study of atmospheric temperatures encountered for the missions of the five-study aircraft indicates that a maximum freeze point of -48 C would not likely create any operational difficulties in Northern Europe.« less

  10. Tuning operating point of extrinsic Fabry-Perot interferometric fiber-optic sensors using microstructured fiber and gas pressure.

    PubMed

    Tian, Jiajun; Zhang, Qi; Fink, Thomas; Li, Hong; Peng, Wei; Han, Ming

    2012-11-15

    Intensity-based demodulation of extrinsic Fabry-Perot interferometric (EFPI) fiber-optic sensors requires the light wavelength to be on the quadrature point of the interferometric fringes for maximum sensitivity. In this Letter, we propose a novel and remote operating-point tuning method for EFPI fiber-optic sensors using microstructured fibers (MFs) and gas pressure. We demonstrated the method using a diaphragm-based EFPI sensor with a microstructured lead-in fiber. The holes in the MF were used as gas channels to remotely control the gas pressure inside the Fabry-Perot cavity. Because of the deformation of the diaphragm with gas pressure, the cavity length and consequently the operating point can be remotely tuned for maximum sensitivity. The proposed operating-point tuning method has the advantage of reduced complexity and cost compared to previously reported methods.

  11. Spatiotemporal attention operator using isotropic contrast and regional homogeneity

    NASA Astrophysics Data System (ADS)

    Palenichka, Roman; Lakhssassi, Ahmed; Zaremba, Marek

    2011-04-01

    A multiscale operator for spatiotemporal isotropic attention is proposed to reliably extract attention points during image sequence analysis. Its consecutive local maxima indicate attention points as the centers of image fragments of variable size with high intensity contrast, region homogeneity, regional shape saliency, and temporal change presence. The scale-adaptive estimation of temporal change (motion) and its aggregation with the regional shape saliency contribute to the accurate determination of attention points in image sequences. Multilocation descriptors of an image sequence are extracted at the attention points in the form of a set of multidimensional descriptor vectors. A fast recursive implementation is also proposed to make the operator's computational complexity independent from the spatial scale size, which is the window size in the spatial averaging filter. Experiments on the accuracy of attention-point detection have proved the operator consistency and its high potential for multiscale feature extraction from image sequences.

  12. PIV study of the wake of a model wind turbine transitioning between operating set points

    NASA Astrophysics Data System (ADS)

    Houck, Dan; Cowen, Edwin (Todd)

    2016-11-01

    Wind turbines are ideally operated at their most efficient tip speed ratio for a given wind speed. There is increasing interest, however, in operating turbines at other set points to increase the overall power production of a wind farm. Specifically, Goit and Meyers (2015) used LES to examine a wind farm optimized by unsteady operation of its turbines. In this study, the wake of a model wind turbine is measured in a water channel using PIV. We measure the wake response to a change in operational set point of the model turbine, e.g., from low to high tip speed ratio or vice versa, to examine how it might influence a downwind turbine. A modified torque transducer after Kang et al. (2010) is used to calibrate in situ voltage measurements of the model turbine's generator operating across a resistance to the torque on the generator. Changes in operational set point are made by changing the resistance or the flow speed, which change the rotation rate measured by an encoder. Single camera PIV on vertical planes reveals statistics of the wake at various distances downstream as the turbine transitions from one set point to another. From these measurements, we infer how the unsteady operation of a turbine may affect the performance of a downwind turbine as its incoming flow. National Science Foundation and the Atkinson Center for a Sustainable Future.

  13. The Efficiency and the Scalability of an Explicit Operator on an IBM POWER4 System

    NASA Technical Reports Server (NTRS)

    Frumkin, Michael; Biegel, Bryan A. (Technical Monitor)

    2002-01-01

    We present an evaluation of the efficiency and the scalability of an explicit CFD operator on an IBM POWER4 system. The POWER4 architecture exhibits a common trend in HPC architectures: boosting CPU processing power by increasing the number of functional units, while hiding the latency of memory access by increasing the depth of the memory hierarchy. The overall machine performance depends on the ability of the caches-buses-fabric-memory to feed the functional units with the data to be processed. In this study we evaluate the efficiency and scalability of one explicit CFD operator on an IBM POWER4. This operator performs computations at the points of a Cartesian grid and involves a few dozen floating point numbers and on the order of 100 floating point operations per grid point. The computations in all grid points are independent. Specifically, we estimate the efficiency of the RHS operator (SP of NPB) on a single processor as the observed/peak performance ratio. Then we estimate the scalability of the operator on a single chip (2 CPUs), a single MCM (8 CPUs), 16 CPUs, and the whole machine (32 CPUs). Then we perform the same measurements for a chache-optimized version of the RHS operator. For our measurements we use the HPM (Hardware Performance Monitor) counters available on the POWER4. These counters allow us to analyze the obtained performance results.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlichenmaier, M

    Recently, Lax operator algebras appeared as a new class of higher genus current-type algebras. Introduced by Krichever and Sheinman, they were based on Krichever's theory of Lax operators on algebraic curves. These algebras are almost-graded Lie algebras of currents on Riemann surfaces with marked points (in-points, out-points and Tyurin points). In a previous joint article with Sheinman, the author classified the local cocycles and associated almost-graded central extensions in the case of one in-point and one out-point. It was shown that the almost-graded extension is essentially unique. In this article the general case of Lax operator algebras corresponding to several in- andmore » out-points is considered. As a first step they are shown to be almost-graded. The grading is given by splitting the marked points which are non-Tyurin points into in- and out-points. Next, classification results both for local and bounded cocycles are proved. The uniqueness theorem for almost-graded central extensions follows. To obtain this generalization additional techniques are needed which are presented in this article. Bibliography: 30 titles.« less

  15. 78 FR 61401 - Entergy Nuclear Operations, Inc.; Big Rock Point; Independent Spent Fuel Storage Installation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-03

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-155; 72-43 and NRC-2013-0218] Entergy Nuclear Operations, Inc.; Big Rock Point; Independent Spent Fuel Storage Installation AGENCY: Nuclear Regulatory... the Big Rock Point (BRP) Independent Spent Fuel Storage Installation (ISFSI). ADDRESSES: Please refer...

  16. Robotic autopositioning of the operating microscope.

    PubMed

    Oppenlander, Mark E; Chowdhry, Shakeel A; Merkl, Brandon; Hattendorf, Guido M; Nakaji, Peter; Spetzler, Robert F

    2014-06-01

    Use of the operating microscope has become pervasive since its introduction to the neurosurgical world. Neuronavigation fused with the operating microscope has allowed accurate correlation of the focal point of the microscope and its location on the downloaded imaging study. However, the robotic ability of the Pentero microscope has not been utilized to orient the angle of the microscope or to change its focal length to hone in on a predefined target. To report a novel technology that allows automatic positioning of the operating microscope onto a set target and utilization of a planned trajectory, either determined with the StealthStation S7 by using preoperative imaging or intraoperatively with the microscope. By utilizing the current motorized capabilities of the Zeiss OPMI Pentero microscope, a robotic autopositioning feature was developed in collaboration with Surgical Technologies, Medtronic, Inc. (StealthStation S7). The system is currently being tested at the Barrow Neurological Institute. Three options were developed for automatically positioning the microscope: AutoLock Current Point, Align Parallel to Plan, and Point to Plan Target. These options allow the microscope to pivot around the lesion, hover in a set plane parallel to the determined trajectory, or rotate and point to a set target point, respectively. Integration of automatic microscope positioning into the operative workflow has potential to increase operative efficacy and safety. This technology is best suited for precise trajectories and entry points into deep-seated lesions.

  17. Rulemaking Petition to lower the threshold that qualifies animal feeding operations (“AFOs”) as concentrated animal feeding operations (“CAFOs”) and thereby “point sources” under section 402 of the Clean Water Act (“CWA”)

    EPA Pesticide Factsheets

    Rulemaking Petition submitted September 20, 2015 to lower the threshold that qualifies animal feeding operations (AFOs) as concentrated animal feeding operations (CAFOs) and thereby point sources under§ 402 of the Clean Water Act (CWA).

  18. Corner-corrected diagonal-norm summation-by-parts operators for the first derivative with increased order of accuracy

    NASA Astrophysics Data System (ADS)

    Del Rey Fernández, David C.; Boom, Pieter D.; Zingg, David W.

    2017-02-01

    Combined with simultaneous approximation terms, summation-by-parts (SBP) operators offer a versatile and efficient methodology that leads to consistent, conservative, and provably stable discretizations. However, diagonal-norm operators with a repeating interior-point operator that have thus far been constructed suffer from a loss of accuracy. While on the interior, these operators are of degree 2p, at a number of nodes near the boundaries, they are of degree p, and therefore of global degree p - meaning the highest degree monomial for which the operators are exact at all nodes. This implies that for hyperbolic problems and operators of degree greater than unity they lead to solutions with a global order of accuracy lower than the degree of the interior-point operator. In this paper, we develop a procedure to construct diagonal-norm first-derivative SBP operators that are of degree 2p at all nodes and therefore can lead to solutions of hyperbolic problems of order 2 p + 1. This is accomplished by adding nonzero entries in the upper-right and lower-left corners of SBP operator matrices with a repeating interior-point operator. This modification necessitates treating these new operators as elements, where mesh refinement is accomplished by increasing the number of elements in the mesh rather than increasing the number of nodes. The significant improvements in accuracy of this new family, for the same repeating interior-point operator, are demonstrated in the context of the linear convection equation.

  19. 43 CFR 3809.301 - Where do I file my notice and what information must I include in it?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... within 30 calendar days of any change of operator or corporate point of contact, or of the mailing address of the operator or corporate point of contact. ... include the following information: (1) Operator Information. The name, mailing address, phone number...

  20. 43 CFR 3809.301 - Where do I file my notice and what information must I include in it?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... within 30 calendar days of any change of operator or corporate point of contact, or of the mailing address of the operator or corporate point of contact. ... include the following information: (1) Operator Information. The name, mailing address, phone number...

  1. 43 CFR 3809.301 - Where do I file my notice and what information must I include in it?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... within 30 calendar days of any change of operator or corporate point of contact, or of the mailing address of the operator or corporate point of contact. ... include the following information: (1) Operator Information. The name, mailing address, phone number...

  2. 43 CFR 3809.301 - Where do I file my notice and what information must I include in it?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... within 30 calendar days of any change of operator or corporate point of contact, or of the mailing address of the operator or corporate point of contact. ... include the following information: (1) Operator Information. The name, mailing address, phone number...

  3. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  4. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  5. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  6. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  7. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  8. Design and FPGA Implementation of a Universal Chaotic Signal Generator Based on the Verilog HDL Fixed-Point Algorithm and State Machine Control

    NASA Astrophysics Data System (ADS)

    Qiu, Mo; Yu, Simin; Wen, Yuqiong; Lü, Jinhu; He, Jianbin; Lin, Zhuosheng

    In this paper, a novel design methodology and its FPGA hardware implementation for a universal chaotic signal generator is proposed via the Verilog HDL fixed-point algorithm and state machine control. According to continuous-time or discrete-time chaotic equations, a Verilog HDL fixed-point algorithm and its corresponding digital system are first designed. In the FPGA hardware platform, each operation step of Verilog HDL fixed-point algorithm is then controlled by a state machine. The generality of this method is that, for any given chaotic equation, it can be decomposed into four basic operation procedures, i.e. nonlinear function calculation, iterative sequence operation, iterative values right shifting and ceiling, and chaotic iterative sequences output, each of which corresponds to only a state via state machine control. Compared with the Verilog HDL floating-point algorithm, the Verilog HDL fixed-point algorithm can save the FPGA hardware resources and improve the operation efficiency. FPGA-based hardware experimental results validate the feasibility and reliability of the proposed approach.

  9. AALC Fan Model Test Program

    DTIC Science & Technology

    1979-05-08

    Prediction. Scaling. Fan Design. 29AOSY14ACY (Cettm.. a P#`04 rv1s. *It UO004N 01- dew 16001 bYstI 610 01c Nh A 12-inch-diameter centrifugal fan impeller...Performance, 3500 RPM84............ 53 Inlet Bellmouth Velocity Survey , Oper Point A, Config 3. 54 Inlet Bellmouth Velocity Survey, Oper Point B...Config 3. 8& 55 Inlet Bellmouth Velocity Survey, Oper Point C, Config 3. ss So Volute Exit Plane Press. Measurement Locations, Config 3 89 57 Volute Exit

  10. The Apache Point Observatory Lunar Laser-ranging Operation: Instrument Description and First Detections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, TW; Adelberger, Eric G.; Battat, J.

    2008-01-01

    A next-generation lunar laser ranging apparatus using the 3.5 m telescope at the Apache Point Observatory in southern New Mexico has begun science operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation) has achieved one-millimeter range precision to the moon which should lead to aproximately one-orderof-magnitude improvements in the precision of several tests of fundamental properties of gravity. We briefly motivate the scientific goals, and then give a detailed discussion of the APOLLO instrumentation.

  11. More on boundary holographic Witten diagrams

    NASA Astrophysics Data System (ADS)

    Sato, Yoshiki

    2018-01-01

    In this paper we discuss geodesic Witten diagrams in general holographic conformal field theories with boundary or defect. In boundary or defect conformal field theory, two-point functions are nontrivial and can be decomposed into conformal blocks in two distinct ways; ambient channel decomposition and boundary channel decomposition. In our previous work [A. Karch and Y. Sato, J. High Energy Phys. 09 (2017) 121., 10.1007/JHEP09(2017)121] we only consider two-point functions of same operators. We generalize our previous work to a situation where operators in two-point functions are different. We obtain two distinct decomposition for two-point functions of different operators.

  12. A test of the AdS/CFT duality on the Coulomb branch

    NASA Astrophysics Data System (ADS)

    Costa, M. S.

    2000-06-01

    We consider the /N=4 /SU(N) Super Yang Mills theory on the Coulomb branch with gauge symmetry broken to S(U(N1)×U(N2)). By integrating the W particles, the effective action near the IR SU(Ni) conformal fixed points is seen to be a deformation of the Super Yang Mills theory by a non-renormalized, irrelevant, dimension 8 operator. The correction to the two-point function of the dilaton field dual operator near the IR is related to a three-point function of chiral primary operators at the conformal fixed points and agrees with the classical gravity prediction, including the numerical factor.

  13. Protection Relaying Scheme Based on Fault Reactance Operation Type

    NASA Astrophysics Data System (ADS)

    Tsuji, Kouichi

    The theories of operation of existing relays are roughly divided into two types: one is the current differential types based on Kirchhoff's first law and the other is impedance types based on second law. We can apply the Kirchhoff's laws to strictly formulate fault phenomena, so the circuit equations are represented non linear simultaneous equations with variables fault point k and fault resistance Rf. This method has next two defect. 1) heavy computational burden for the iterative calculation on N-R method, 2) relay operator can not easily understand principle of numerical matrix operation. The new protection relay principles we proposed this paper focuses on the fact that the reactance component on fault point is almost zero. Two reactance Xf(S), Xf(R) on branch both ends are calculated by operation of solving linear equations. If signs of Xf(S) and Xf(R) are not same, it can be judged that the fault point exist in the branch. This reactance Xf corresponds to difference of branch reactance between actual fault point and imaginaly fault point. And so relay engineer can to understand fault location by concept of “distance". The simulation results using this new method indicates the highly precise estimation of fault locations compared with the inspected fault locations on operating transmission lines.

  14. 34 CFR 644.21 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provided under paragraph (a) of this section, and attainable, given the project's plan of operation, budget... applications. (c) Plan of operation (30 points). The Secretary evaluates the quality of the applicant's plan of operation on the basis of the following: (1) (4 points) The plan to inform the residents, schools, and...

  15. 34 CFR 644.21 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... provided under paragraph (a) of this section, and attainable, given the project's plan of operation, budget... applications. (c) Plan of operation (30 points). The Secretary evaluates the quality of the applicant's plan of operation on the basis of the following: (1) (4 points) The plan to inform the residents, schools, and...

  16. 34 CFR 644.21 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... provided under paragraph (a) of this section, and attainable, given the project's plan of operation, budget... applications. (c) Plan of operation (30 points). The Secretary evaluates the quality of the applicant's plan of operation on the basis of the following: (1) (4 points) The plan to inform the residents, schools, and...

  17. 34 CFR 644.21 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... provided under paragraph (a) of this section, and attainable, given the project's plan of operation, budget... applications. (c) Plan of operation (30 points). The Secretary evaluates the quality of the applicant's plan of operation on the basis of the following: (1) (4 points) The plan to inform the residents, schools, and...

  18. 78 FR 44881 - Drawbridge Operation Regulation; York River, Between Yorktown and Gloucester Point, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... deviation from the operating schedule that governs the operation of the Coleman Memorial Bridge (US 17/George P. Coleman Memorial Swing Bridge) across the York River, mile 7.0, between Gloucester Point and Yorktown, VA. This deviation is necessary to facilitate maintenance work on the moveable spans on the...

  19. [Tossy III injuries of the acromioclavicular joint. In what circumstances is surgery still justified? Personal results and literature review].

    PubMed

    Prokop, A; Helling, H J; Andermahr, J; Mönig, S; Rehm, K E

    2003-05-01

    In Germany AC-joint-dislocations type Tossy III are treated in most of the cases operatively. Over two times of period we treated AC-joint-dislocations type Tossy III with biodegradable PDS-cords. 54 patients were operated between 1989 and 1997 and followed up after 39 months. 87.5% of patients are satisfied with results and have 10.2 points at Taftscore. In this period we couldn't differentiated the results by Rockwood classification. 12 patients with Rockwood V were operated between 1998 and 2002 and followed up after 14 months. Excellent and good results were seen in 92% of cases. At Taftscore we seen 10.7 points. 3 patients with Rockwood III were treated conservative with 10.3 points and 3 patients were operated with 10.7 points at Taftscore. AC-joint dislocations should be classified to Rockwood. No differences were seen between operation and conservative treatment in Rockwood III in literature. We recommend operation with PDS cords with good results in Rockwood V.

  20. A physics-motivated Centroidal Voronoi Particle domain decomposition method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Lin, E-mail: lin.fu@tum.de; Hu, Xiangyu Y., E-mail: xiangyu.hu@tum.de; Adams, Nikolaus A., E-mail: nikolaus.adams@tum.de

    2017-04-15

    In this paper, we propose a novel domain decomposition method for large-scale simulations in continuum mechanics by merging the concepts of Centroidal Voronoi Tessellation (CVT) and Voronoi Particle dynamics (VP). The CVT is introduced to achieve a high-level compactness of the partitioning subdomains by the Lloyd algorithm which monotonically decreases the CVT energy. The number of computational elements between neighboring partitioning subdomains, which scales the communication effort for parallel simulations, is optimized implicitly as the generated partitioning subdomains are convex and simply connected with small aspect-ratios. Moreover, Voronoi Particle dynamics employing physical analogy with a tailored equation of state ismore » developed, which relaxes the particle system towards the target partition with good load balance. Since the equilibrium is computed by an iterative approach, the partitioning subdomains exhibit locality and the incremental property. Numerical experiments reveal that the proposed Centroidal Voronoi Particle (CVP) based algorithm produces high-quality partitioning with high efficiency, independently of computational-element types. Thus it can be used for a wide range of applications in computational science and engineering.« less

  1. The Oscillating Component of the Internal Jugular Vein Flow: The Overlooked Element of Cerebral Circulation

    PubMed Central

    Sisini, Francesco; Toro, Eleuterio; Gambaccini, Mauro; Zamboni, Paolo

    2015-01-01

    The jugular venous pulse (JVP) provides valuable information about cardiac haemodynamics and filling pressures and is an indirect estimate of the central venous pressure (CVP). Recently it has been proven that JVP can be obtained by measuring the cross-sectional area (CSA) of the IJV on each sonogram of an ultrasound B-mode sonogram sequence. It has also been proven that during its pulsation the IJV is distended and hence that the pressure gradient drives the IJV haemodynamics. If this is true, then it will imply the following: (i) the blood velocity in the IJV is a periodic function of the time with period equal to the cardiac period and (ii) the instantaneous blood velocity is given by a time function that can be derived from a flow-dynamics theory that uses the instantaneous pressure gradient as a parameter. The aim of the present study is to confirm the hypothesis that JVP regulates the IJV blood flow and that pressure waves are transmitted from the heart toward the brain through the IJV wall. PMID:26783380

  2. A physics-motivated Centroidal Voronoi Particle domain decomposition method

    NASA Astrophysics Data System (ADS)

    Fu, Lin; Hu, Xiangyu Y.; Adams, Nikolaus A.

    2017-04-01

    In this paper, we propose a novel domain decomposition method for large-scale simulations in continuum mechanics by merging the concepts of Centroidal Voronoi Tessellation (CVT) and Voronoi Particle dynamics (VP). The CVT is introduced to achieve a high-level compactness of the partitioning subdomains by the Lloyd algorithm which monotonically decreases the CVT energy. The number of computational elements between neighboring partitioning subdomains, which scales the communication effort for parallel simulations, is optimized implicitly as the generated partitioning subdomains are convex and simply connected with small aspect-ratios. Moreover, Voronoi Particle dynamics employing physical analogy with a tailored equation of state is developed, which relaxes the particle system towards the target partition with good load balance. Since the equilibrium is computed by an iterative approach, the partitioning subdomains exhibit locality and the incremental property. Numerical experiments reveal that the proposed Centroidal Voronoi Particle (CVP) based algorithm produces high-quality partitioning with high efficiency, independently of computational-element types. Thus it can be used for a wide range of applications in computational science and engineering.

  3. Cleanup Verification Package for the 118-H-6:2, 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils; the 118-H-6:3, 105-H Reactor Fuel Storage Basin and Underlying Soils; The 118-H-6:3 Fuel Storage Basin Deep Zone Side Slope Soils; the 100-H-9, 100-H-10, and 100-H-13 French Drains; the 100-H-11 and 100-H-12 Expansion Box French Drains; and the 100-H-14 and 100-H-31 Surface Contamination Zones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. J. Appel

    2006-06-29

    This cleanup verification package documents completion of removal actions for the 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils (subsite 118-H-6:2); 105-H Reactor Fuel Storage Basin and Underlying Soils (118-H-6:3); and Fuel Storage Basin Deep Zone Side Slope Soils. This CVP also documents remedial actions for the following seven additional waste sties: French Drain C (100-H-9), French Drain D (100-H-10), Expansion Box French Drain E (100-H-11), Expansion Box French Drain F (100-H-12), French Drain G (100-H-13), Surface Contamination Zone H (100-H-14), and the Polychlorinated Biphenyl Surface Contamination Zone (100-H-31).

  4. On Motivating Operations at the Point of Online Purchase Setting

    ERIC Educational Resources Information Center

    Fagerstrom, Asle; Arntzen, Erik

    2013-01-01

    Consumer behavior analysis can be applied over a wide range of economic topics in which the main focus is the contingencies that influence the behavior of the economic agent. This paper provides an overview on the work that has been done on the impact from motivating operations at the point of online purchase situation. Motivating operations, a…

  5. Measurements in discrete hole film cooling behavior with periodic freestream unsteadiness

    NASA Astrophysics Data System (ADS)

    Fan, Danyang; Borup, Daniel D.; Elkins, Christopher J.; Eaton, John K.

    2018-03-01

    Magnetic resonance imaging (MRI) techniques were used to investigate a discrete, 30°-inclined round jet in crossflow subjected to periodic freestream unsteadiness. The freestream perturbations were generated by an oscillating airfoil upstream of the jet. The experiment operated at a Strouhal number of 0.014, channel Reynolds number of 25,000, hole Reynolds number of 2900, and jet blowing ratio of unity. 3D phase locked velocity measurements were obtained over the entire channel using magnetic resonance velocimetry (MRV). 3D time-averaged temperature measurements were acquired using magnetic resonance thermometry (MRT), along with phase-locked temperature measurements in the 2D centerplane of the channel and jet. The freestream flow just upstream of the jet was characterized by streamwise velocities ranging from 0.88 U_ {bulk} to 1.23 U_ {bulk} and wall-normal velocities from -0.11 U_ {bulk} to 0.02 U_ {bulk}. Flow inside the hole was observed to be insensitive to the freestream fluctuations, as velocities and temperatures in the hole remained largely unchanged throughout the cycle. Outside the hole, changes to the streamwise velocity produced an oscillating jet blowing ratio that led to the lengthening and shortening of the counter-rotating vortex pair (CVP) as well as a varying degree of coolant separation from the film cooled wall. During one portion of the cycle, downwashing freestream flow (i.e., flow with negative wall-normal velocities) promoted strong re-attachment and lateral spreading of the jet. Mean, spanwise-averaged film cooling effectiveness values were compared to those of an earlier experiment with a steady freestream and identical geometry, Reynolds number, and blowing ratio. Film cooling performance in the near-hole region was higher with steady freestream flow. However, at downstream locations, the downward transport of coolant by the periodic downwashing flow led to a higher mean surface effectiveness than in the steady case.

  6. Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing

    DTIC Science & Technology

    2018-04-27

    Evaluation Command 6617 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S...AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-188 27 April 2018 DTIC AD No. CHEMICAL POINT DETECTOR VAPOR...188 27 April 2018 2 1. SCOPE. This Test Operations Procedure (TOP), which has been endorsed by the Test and Evaluation Capabilities and

  7. Economics of an ecotourism operation in Belize

    NASA Astrophysics Data System (ADS)

    Kangas, Patrick; Shave, Mary; Shave, Paul

    1995-09-01

    The economic inputs and outputs for the Possum Point Biological Station in Belize during 1990 1992 are described to illustrate some aspects of an ecotourism operation. Eight hundred fifty-four people in 59 groups visited Possum Point during the study period to tour rain forests, estuaries, and coral reefs. The economic input to Possum Point from these groups increased from 74,552 in 1990 to 166,268 in 1992. Outputs were for license fees, capital improvements, goods and services, labor, fossil fuels, and development of a historic sugar mill site. An annual donation was also made to a scholarship fund for local Belizean students. The net cash balance of income and outputs changed from negative (-6678) in 1990 to positive (+4811) in 1992, suggesting development of the economic operation. Possum Point meets the economic criteria for ecotourism by feeding back some tourist monies for community and environmental support, particularly donations for the sugar mill site and the scholarship fund. Most of the outputs from Possum Point (about 80%) were retained in the local economy through employment and purchases, which have a positive influence on the local community. We conclude that ecotourism operations, such as Possum Point, offer important sustainable development opportunities for Belize.

  8. Out-of-Hospital Fluid in Severe Sepsis: Effect on Early Resuscitation in the Emergency Department

    PubMed Central

    Seymour, Christopher W.; Cooke, Colin R.; Mikkelsen, Mark E.; Hylton, Julie; Rea, Tom D.; Goss, Christopher H.; Gaieski, David F.; Band, Roger A.

    2014-01-01

    Background Early identification and treatment of patients with severe sepsis improves outcome, yet the role of out-of-hospital intravenous (IV) fluid is unknown. Objective To determine if the delivery of out-of-hospital fluid in patients with severe sepsis is associated with reduced time to achievement of goal-oriented resuscitation in the emergency department (ED). Methods We performed a secondary data analysis of a retrospective cohort study in a metropolitan, tertiary care, university-based medical center supported by a two-tiered system of out-of-hospital emergency medical services (EMS) providers. We studied the association between delivery of out-of-hospital fluid by advanced life support (ALS) providers and the achievement of resuscitation endpoints (central venous pressure [CVP] ≥8 mmHg, mean arterial pressure [MAP] ≥65 mmHg, and central venous oxygen saturation [ScvO2] ≥70%) within six hours after triage during early goal-directed therapy (EGDT) in the ED. Results Twenty five (48%) of 52 patients transported by ALS with severe sepsis received out-of-hospital fluid. Data for age, gender, source of sepsis, and presence of comorbidities were similar between patients who did and did not receive out-of-hospital fluid. Patients receiving out-of-hospital fluid had lower out-of-hospital mean (± standard deviation) systolic blood pressure (95 ± 40 mmHg vs. 117 ± 29 mmHg; p = 0.03) and higher median (interquartile range) Sequential Organ Failure Assessment (SOFA) scores in the ED (7 [5–8] vs. 4 [4–6]; p = 0.01) than patients not receiving out-of-hospital fluid. Despite greater severity of illness, patients receiving out-of-hospital fluid approached but did not attain a statistically significant increase in the likelihood of achieving MAP ≥65 mmHg within six hours after ED triage (70% vs. 44%, p = 0.09). On average, patients receiving out-of-hospital fluid received twice the fluid volume within one hour after ED triage (1.1 L [1.0–2.0 L] vs. 0.6 L [0.3–1.0 L]; p 0.01). No difference in achievement of goal CVP (72% vs. 60%; p = 0.6) or goal ScvO2 (54% vs. 36%; p = 0.25) was observed between groups. Conclusions Less than half of patients with severe sepsis transported by ALS received out-of-hospital fluid. Patients receiving out-of-hospital IV access and fluids approached but did not attain a statistically significant increase in the likelihood of achieving goal MAP during EGDT. These preliminary findings require additional investigation to evaluate the optimal role of out-of-hospital resuscitation in treating patients with severe sepsis. PMID:20199228

  9. 47 CFR 15.249 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875 MHZ, and 24.0-24.25 GHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency Field strength of fundamental (millivolts/meter) Field strength of harmonics (microvolts..., point-to-point operation as referred to in this paragraph shall be limited to systems employing a fixed...

  10. The Military Assistance Command-Vietnam Studies and Observations Group-A Case Study in Special Operations Campaigning

    DTIC Science & Technology

    2016-06-10

    viewed as the panacea for all military problems. Politicians view SOF as a low risk minimalist investment that produces results; even for problems...of published work that has been dedicated to discussing special operations theory as an element of military strategy. A good starting point to...utility. Doctrine As a starting point for framing understanding of special operations, Joint Publication (JP) 3-05 Special Operations, provides the basis

  11. 77 FR 66492 - Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point 2, LLC, and Entergy Nuclear Indian...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-05

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos.: 50-003, 50-247, 50-286; NRC-2012-0265: License Nos.: DPR- 5, DPR-26, and DPR-64] Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point 2, LLC, and Entergy Nuclear Indian Point 3, LLC; Issuance of Director's Decision Notice is hereby given that the Director, Office of Nuclear Reactor Regulation...

  12. Viscous Three-Dimensional Simulation of Flow in an Axial Low Pressure Compressor at Engine Icing Operating Points

    NASA Technical Reports Server (NTRS)

    Rigby, David L.; Ameri, Ali A.; Veres, Joe; Jorgenson, Philip C. E.

    2017-01-01

    Viscous three-dimensional simulations of the Honeywell ALF502R-5 low pressure compressor (sometimes called a booster) using the NASA Glenn code GlennHT have been carried out. A total of ten simulations were produced. Five operating points are investigated, with each point run with two different wall thermal conditions. These operating points are at, or near, points where engine icing has been determined to be likely. In the future, the results of this study will be used for further analysis such as predicting collection efficiency of ice particles and ice growth rates at various locations in the compressor. A mixing plane boundary condition is used between each blade row, resulting in convergence to steady state within each blade row. The k-omega turbulence model of Wilcox, combined with viscous grid spacing near the wall on the order of one, is used to resolve the turbulent boundary layers. For each of the operating points, heat transfer coefficients are generated on the blades and walls. The heat transfer coefficients are produced by running the operating point with two different wall thermal conditions and then solving simultaneously for the heat transfer coefficient and adiabatic wall temperature at each point. Average Nusselt numbers are calculated for the most relevant surfaces. The values are seen to scale with Reynolds number to approximately a power of 0.7. Additionally, images of surface distribution of Nusselt number are presented. Qualitative comparison between the five operating points show that there is relatively little change in the character of the distribution. The dominant observed effect is that of an overall scaling, which is expected due to Reynolds number differences. One interesting aspect about the Nusselt number distribution is observed on the casing (outer diameter) downstream of the exit guide vanes (EGVs). The Nusselt number is relatively high between the pairs of EGVs, with two lower troughs downstream of each EGV trailing edge. This is of particular interest since rather complex ice shapes have been observed in that region.

  13. Renormalization of quark bilinear operators in a momentum-subtraction scheme with a nonexceptional subtraction point

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sturm, C.; Soni, A.; Aoki, Y.

    2009-07-01

    We extend the Rome-Southampton regularization independent momentum-subtraction renormalization scheme (RI/MOM) for bilinear operators to one with a nonexceptional, symmetric subtraction point. Two-point Green's functions with the insertion of quark bilinear operators are computed with scalar, pseudoscalar, vector, axial-vector and tensor operators at one-loop order in perturbative QCD. We call this new scheme RI/SMOM, where the S stands for 'symmetric'. Conversion factors are derived, which connect the RI/SMOM scheme and the MS scheme and can be used to convert results obtained in lattice calculations into the MS scheme. Such a symmetric subtraction point involves nonexceptional momenta implying a lattice calculation withmore » substantially suppressed contamination from infrared effects. Further, we find that the size of the one-loop corrections for these infrared improved kinematics is substantially decreased in the case of the pseudoscalar and scalar operator, suggesting a much better behaved perturbative series. Therefore it should allow us to reduce the error in the determination of the quark mass appreciably.« less

  14. Computational Aerodynamic Simulations of a 1215 ft/sec Tip Speed Transonic Fan System Model for Acoustic Methods Assessment and Development

    NASA Technical Reports Server (NTRS)

    Tweedt, Daniel L.

    2014-01-01

    Computational Aerodynamic simulations of a 1215 ft/sec tip speed transonic fan system were performed at five different operating points on the fan operating line, in order to provide detailed internal flow field information for use with fan acoustic prediction methods presently being developed, assessed and validated. The fan system is a sub-scale, low-noise research fan/nacelle model that has undergone extensive experimental testing in the 9- by 15-foot Low Speed Wind Tunnel at the NASA Glenn Research Center. Details of the fan geometry, the computational fluid dynamics methods, the computational grids, and various computational parameters relevant to the numerical simulations are discussed. Flow field results for three of the five operating points simulated are presented in order to provide a representative look at the computed solutions. Each of the five fan aerodynamic simulations involved the entire fan system, which for this model did not include a split flow path with core and bypass ducts. As a result, it was only necessary to adjust fan rotational speed in order to set the fan operating point, leading to operating points that lie on a fan operating line and making mass flow rate a fully dependent parameter. The resulting mass flow rates are in good agreement with measurement values. Computed blade row flow fields at all fan operating points are, in general, aerodynamically healthy. Rotor blade and fan exit guide vane flow characteristics are good, including incidence and deviation angles, chordwise static pressure distributions, blade surface boundary layers, secondary flow structures, and blade wakes. Examination of the flow fields at all operating conditions reveals no excessive boundary layer separations or related secondary-flow problems.

  15. Common fixed points in best approximation for Banach operator pairs with Ciric type I-contractions

    NASA Astrophysics Data System (ADS)

    Hussain, N.

    2008-02-01

    The common fixed point theorems, similar to those of Ciric [Lj.B. Ciric, On a common fixed point theorem of a Gregus type, Publ. Inst. Math. (Beograd) (N.S.) 49 (1991) 174-178; Lj.B. Ciric, On Diviccaro, Fisher and Sessa open questions, Arch. Math. (Brno) 29 (1993) 145-152; Lj.B. Ciric, On a generalization of Gregus fixed point theorem, Czechoslovak Math. J. 50 (2000) 449-458], Fisher and Sessa [B. Fisher, S. Sessa, On a fixed point theorem of Gregus, Internat. J. Math. Math. Sci. 9 (1986) 23-28], Jungck [G. Jungck, On a fixed point theorem of Fisher and Sessa, Internat. J. Math. Math. Sci. 13 (1990) 497-500] and Mukherjee and Verma [R.N. Mukherjee, V. Verma, A note on fixed point theorem of Gregus, Math. Japon. 33 (1988) 745-749], are proved for a Banach operator pair. As applications, common fixed point and approximation results for Banach operator pair satisfying Ciric type contractive conditions are obtained without the assumption of linearity or affinity of either T or I. Our results unify and generalize various known results to a more general class of noncommuting mappings.

  16. Imaging diagnostics in ovarian cancer: magnetic resonance imaging and a scoring system guiding choice of primary treatment.

    PubMed

    Kasper, Sigrid M; Dueholm, Margit; Marinovskij, Edvard; Blaakær, Jan

    2017-03-01

    To analyze the ability of magnetic resonance imaging (MRI) and systematic evaluation at surgery to predict optimal cytoreduction in primary advanced ovarian cancer and to develop a preoperative scoring system for cancer staging. Preoperative MRI and standard laparotomy were performed in 99 women with either ovarian or primary peritoneal cancer. Using univariate and multivariate logistic regression analysis of a systematic description of the tumor in nine abdominal compartments obtained by MRI and during surgery plus clinical parameters, a scoring system was designed that predicted non-optimal cytoreduction. Non-optimal cytoreduction at operation was predicted by the following: (A) presence of comorbidities group 3 or 4 (ASA); (B) tumor presence in multiple numbers of different compartments, and (C) numbers of specified sites of organ involvement. The score includes: number of compartments involved (1-9 points), >1 subdiaphragmal location with presence of tumor (1 point); deep organ involvement of liver (1 point), porta hepatis (1 point), spleen (1 point), mesentery/vessel (1 point), cecum/ileocecal (1 point), rectum/vessels (1 point): ASA groups 3 and 4 (2 points). Use of the scoring system based on operative findings gave an area under the curve (AUC) of 91% (85-98%) for patients in whom optimal cytoreduction could not be achieved. The score AUC obtained by MRI was 84% (76-92%), and 43% of non-optimal cytoreduction patients were identified, with only 8% of potentially operable patients being falsely evaluated as suitable for non-optimal cytoreduction at the most optimal cut-off value. Tumor in individual locations did not predict operability. This systematic scoring system based on operative findings and MRI may predict non-optimal cytoreduction. MRI is able to assess ovarian cancer with peritoneal carcinomatosis with satisfactory concordance with laparotomic findings. This scoring system could be useful as a clinical guideline and should be evaluated and developed further in larger studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Liquid metal heat exchanger for efficient heating of soils and geologic formations

    DOEpatents

    DeVault, Robert C [Knoxville, TN; Wesolowski, David J [Kingston, TN

    2010-02-23

    Apparatus for efficient heating of subterranean earth includes a well-casing that has an inner wall and an outer wall. A heater is disposed within the inner wall and is operable within a preselected operating temperature range. A heat transfer metal is disposed within the outer wall and without the inner wall, and is characterized by a melting point temperature lower than the preselected operating temperature range and a boiling point temperature higher than the preselected operating temperature range.

  18. Superconductor-normal-superconductor with distributed Sharvin point contacts

    DOEpatents

    Holcomb, Matthew J.; Little, William A.

    1994-01-01

    A non-linear superconducting junction device comprising a layer of high transient temperature superconducting material which is superconducting at an operating temperature, a layer of metal in contact with the layer of high temperature superconducting material and which remains non-superconducting at the operating temperature, and a metal material which is superconducting at the operating temperature and which forms distributed Sharvin point contacts with the metal layer.

  19. A multiple objective optimization approach to quality control

    NASA Technical Reports Server (NTRS)

    Seaman, Christopher Michael

    1991-01-01

    The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios: tuning of process controllers to meet specified performance objectives and tuning of process inputs to meet specified quality objectives. Five case studies are presented.

  20. 12. VIEW OF OPERATING ROOMRCA COMMUNICATION REC STATION (THIS ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. VIEW OF OPERATING ROOM-RCA COMMUNICATION REC STATION (THIS ROOM WAS ORIGINALLY A MOTOR GENERATOR FACILITY AND SUPPLIED DC POWER TO AN EARLIER GENERATION OF POINT-TO-POINT RECEIVERS ON SECOND FLOOR). VIEW SHOWS TRANSMITTER CONTROL STATION AND AUDIO CONTROL STATION (LEFT, WATKINS-JOHNSON WJ-8718-23. HP RECEIVERS AND KENWOOD R-5000 COMMUNICATIONS RECEIVERS (220 DEGREES). - Marconi Radio Sites, Receiving, Point Reyes Station, Marin County, CA

  1. Comparison of the operational and safety characteristics of the single point urban and diamond interchanges.

    DOT National Transportation Integrated Search

    1996-01-01

    The purpose of this study was to evaluate and compare the safety and operational characteristics of the single point urban interchange (SPUI) and the diamond interchange (DI) and develop guidelines that identify traffic and/or geometric conditions th...

  2. Instabilities caused by floating-point arithmetic quantization.

    NASA Technical Reports Server (NTRS)

    Phillips, C. L.

    1972-01-01

    It is shown that an otherwise stable digital control system can be made unstable by signal quantization when the controller operates on floating-point arithmetic. Sufficient conditions of instability are determined, and an example of loss of stability is treated when only one quantizer is operated.

  3. Existence of tripled fixed points for a class of condensing operators in Banach spaces.

    PubMed

    Karakaya, Vatan; Bouzara, Nour El Houda; Doğan, Kadri; Atalan, Yunus

    2014-01-01

    We give some results concerning the existence of tripled fixed points for a class of condensing operators in Banach spaces. Further, as an application, we study the existence of solutions for a general system of nonlinear integral equations.

  4. Sound source localization on an axial fan at different operating points

    NASA Astrophysics Data System (ADS)

    Zenger, Florian J.; Herold, Gert; Becker, Stefan; Sarradj, Ennes

    2016-08-01

    A generic fan with unskewed fan blades is investigated using a microphone array method. The relative motion of the fan with respect to the stationary microphone array is compensated by interpolating the microphone data to a virtual rotating array with the same rotational speed as the fan. Hence, beamforming algorithms with deconvolution, in this case CLEAN-SC, could be applied. Sound maps and integrated spectra of sub-components are evaluated for five operating points. At selected frequency bands, the presented method yields sound maps featuring a clear circular source pattern corresponding to the nine fan blades. Depending on the adjusted operating point, sound sources are located on the leading or trailing edges of the fan blades. Integrated spectra show that in most cases leading edge noise is dominant for the low-frequency part and trailing edge noise for the high-frequency part. The shift from leading to trailing edge noise is strongly dependent on the operating point and frequency range considered.

  5. Computer-aided placement of deep brain stimulators: from planning to intraoperative guidance

    NASA Astrophysics Data System (ADS)

    D'Haese, Pierre-Francois; Pallavaram, Srivatsan; Kao, Chris; Konrad, Peter E.; Dawant, Benoit M.

    2005-04-01

    The long term objective of our research is to develop a system that will automate as much as possible DBS implantation procedures. It is estimated that about 180,000 patients/year would benefit from DBS implantation. Yet, only 3000 procedures are performed annually. This is so because the combined expertise required to perform the procedure successfully is only available at a limited number of sites. Our goal is to transform this procedure into a procedure that can be performed by a general neurosurgeon at a community hospital. In this work we report on our current progress toward developing a system for the computer-assisted pre-operative selection of target points and for the intra-operative adjustment of these points. The system consists of a deformable atlas of optimal target points that can be used to select automatically the pre-operative target, of an electrophysiological atlas, and of an intra-operative interface. The atlas is deformed using a rigid then a non-rigid registration algorithm developed at our institution. Results we have obtained show that automatic prediction of target points is an achievable goal. Our results also indicate that electrophysiological information can be used to resolve structures not visible in anatomic images, thus improving both pre-operative and intra-operative guidance. Our intra-operative system has reached the stage of a working prototype that is clinically used at our institution.

  6. LIDAR Point Cloud Data Extraction and Establishment of 3D Modeling of Buildings

    NASA Astrophysics Data System (ADS)

    Zhang, Yujuan; Li, Xiuhai; Wang, Qiang; Liu, Jiang; Liang, Xin; Li, Dan; Ni, Chundi; Liu, Yan

    2018-01-01

    This paper takes the method of Shepard’s to deal with the original LIDAR point clouds data, and generate regular grid data DSM, filters the ground point cloud and non ground point cloud through double least square method, and obtains the rules of DSM. By using region growing method for the segmentation of DSM rules, the removal of non building point cloud, obtaining the building point cloud information. Uses the Canny operator to extract the image segmentation is needed after the edges of the building, uses Hough transform line detection to extract the edges of buildings rules of operation based on the smooth and uniform. At last, uses E3De3 software to establish the 3D model of buildings.

  7. Life Cycle Assessment of the MBT plant in Ano Liossia, Athens, Greece

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abeliotis, Konstadinos, E-mail: kabeli@hua.gr; Kalogeropoulos, Alexandros; Lasaridi, Katia

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer We model the operation of an MBT plant in Greece based on LCA. Black-Right-Pointing-Pointer We compare four different MBT operating scenarios (among them and with landfilling). Black-Right-Pointing-Pointer Even the current operation of the MBT plant is preferable to landfilling. Black-Right-Pointing-Pointer Utilization of the MBT compost and metals generates the most environmental gains. Black-Right-Pointing-Pointer Thermal exploitation of RDF improves further the environmental performance of the plant. - Abstract: The aim of this paper is the application of Life Cycle Assessment to the operation of the MBT facility of Ano Liossia in the region of Attica in Greece. The regionmore » of Attica is home to almost half the population of Greece and the management of its waste is a major issue. In order to explicitly analyze the operation of the MBT plant, five scenarios were generated. Actual operation data of the MBT plant for the year 2008 were provided by the region of Attica and the LCA modeling was performed via the SimaPro 5.1 software while impact assessment was performed utilizing the Eco-indicator'99 method. The results of our analysis indicate that even the current operation of the MBT plant is preferable to landfilling. Among the scenarios of MBT operation, the one with complete utilization of the MBT outputs, i.e. compost, RDF, ferrous and non-ferrous metals, is the one that generates the most environmental gains. Our analysis indicates that the exploitation of RDF via incineration is the key factor towards improving the environmental performance of the MBT plant. Our findings provide a quantitative understanding of the MBT plant. Interpretation of results showed that proper operation of the modern waste management systems can lead to substantial reduction of environmental impacts and savings of resources.« less

  8. Deep Space One High-Voltage Bus Management

    NASA Technical Reports Server (NTRS)

    Rachocki, Ken; Nieraeth, Donald

    1999-01-01

    The design of the High Voltage Power Converter Unit on DS1 allows both the spacecraft avionics and ion propulsion to operate in a stable manner near the PPP of the solar array. This approach relies on a fairly well-defined solar array model to determine the projected PPP. The solar array voltage set-points have to be updated every week to maintain operation near PPP. Stable operation even to the LEFT of the Peak Power Point is achievable so long as you do not change the operating power level of the ion engine. The next step for this technology is to investigate the use of onboard autonomy to determine the optimum SA voltage regulation set-point (i.e. near the PPP); this is for future missions that have one or more ion propulsion subsystems.

  9. 29 CFR 1926.300 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... apply to concrete vibrators, concrete breakers, powered tampers, jack hammers, rock drills, and similar... guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points...

  10. 29 CFR 1926.300 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... apply to concrete vibrators, concrete breakers, powered tampers, jack hammers, rock drills, and similar... guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points...

  11. 29 CFR 1926.300 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... apply to concrete vibrators, concrete breakers, powered tampers, jack hammers, rock drills, and similar... guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points...

  12. 76 FR 60732 - Drawbridge Operation Regulations; Navesink (Swimming) River, NJ

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... Operation Regulations; Navesink (Swimming) River, NJ AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... (Swimming) River between Oceanic and Locust Point, New Jersey. The deviation is necessary to facilitate...: The Oceanic Bridge, across the Navesink (Swimming) River, mile 4.5, between Oceanic and Locust Point...

  13. 78 FR 52987 - Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Unit 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-286; NRC-2013-0063] Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Environmental assessment and finding of no significant impact; issuance. SUMMARY: The U.S. Nuclear Regulatory Commission...

  14. ATP-gamma-S shifts the operating point of outer hair cell transduction towards scala tympani.

    PubMed

    Bobbin, Richard P; Salt, Alec N

    2005-07-01

    ATP receptor agonists and antagonists alter cochlear mechanics as measured by changes in distortion product otoacoustic emissions (DPOAE). Some of the effects on DPOAEs are consistent with the hypothesis that ATP affects mechano-electrical transduction and the operating point of the outer hair cells (OHCs). This hypothesis was tested by monitoring the effect of ATP-gamma-S on the operating point of the OHCs. Guinea pigs anesthetized with urethane and with sectioned middle ear muscles were used. The cochlear microphonic (CM) was recorded differentially (scala vestibuli referenced to scala tympani) across the basal turn before and after perfusion (20 min) of the perilymph compartment with artificial perilymph (AP) and ATP-gamma-S dissolved in AP. The operating point was derived from the cochlear microphonics (CM) recorded in response low frequency (200 Hz) tones at high level (106, 112 and 118 dB SPL). The analysis procedure used a Boltzmann function to simulate the CM waveform and the Boltzmann parameters were adjusted to best-fit the calculated waveform to the CM. Compared to the initial perfusion with AP, ATP-gamma-S (333 microM) enhanced peak clipping of the positive peak of the CM (that occurs during organ of Corti displacements towards scala tympani), which was in keeping with ATP-induced displacement of the transducer towards scala tympani. CM waveform analysis quantified the degree of displacement and showed that the changes were consistent with the stimulus being centered on a different region of the transducer curve. The change of operating point meant that the stimulus was applied to a region of the transducer curve where there was greater saturation of the output on excursions towards scala tympani and less saturation towards scala vestibuli. A significant degree of recovery of the operating point was observed after washing with AP. Dose response curves generated by perfusing ATP-gamma-S (333 microM) in a cumulative manner yielded an EC(50) of 19.8 microM. The ATP antagonist PPADS (0.1 mM) failed to block the effect of ATP-gamma-S on operating point, suggesting the response was due to activation of metabotropic and not ionotropic ATP receptors. Multiple perfusions of AP had no significant effect (118 and 112 dB) or moved the operating point slightly (106 dB) in the direction opposite of ATP-gamma-S. Results are consistent with an ATP-gamma-S induced transducer change comparable to a static movement of the organ of Corti or reticular lamina towards scala tympani.

  15. Performance evaluation of an anaerobic/aerobic landfill-based digester using yard waste for energy and compost production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yazdani, Ramin, E-mail: ryazdani@sbcglobal.net; Civil and Environmental Engineering, University of California, One Shields Avenue, Ghausi Hall, Davis, CA 95616; Barlaz, Morton A., E-mail: barlaz@eos.ncsu.edu

    2012-05-15

    Highlights: Black-Right-Pointing-Pointer Biochemical methane potential decreased by 83% during the two-stage operation. Black-Right-Pointing-Pointer Net energy produced was 84.3 MWh or 46 kWh per million metric tons (Mg). Black-Right-Pointing-Pointer The average removal efficiency of volatile organic compounds (VOCs) was 96-99%. Black-Right-Pointing-Pointer The average removal efficiency of non-methane organic compounds (NMOCs) was 68-99%. Black-Right-Pointing-Pointer The two-stage batch digester proved to be simple to operate and cost-effective. - Abstract: The objective of this study was to evaluate a new alternative for yard waste management by constructing, operating and monitoring a landfill-based two-stage batch digester (anaerobic/aerobic) with the recovery of energy and compost. Themore » system was initially operated under anaerobic conditions for 366 days, after which the yard waste was aerated for an additional 191 days. Off gas generated from the aerobic stage was treated by biofilters. Net energy recovery was 84.3 MWh, or 46 kWh per million metric tons of wet waste (as received), and the biochemical methane potential of the treated waste decreased by 83% during the two-stage operation. The average removal efficiencies of volatile organic compounds and non-methane organic compounds in the biofilters were 96-99% and 68-99%, respectively.« less

  16. Pointing control for the International Comet Mission

    NASA Technical Reports Server (NTRS)

    Leblanc, D. R.; Schumacher, L. L.

    1980-01-01

    The design of the pointing control system for the proposed International Comet Mission, intended to fly by Comet Halley and rendezvous with Comet Tempel-2 is presented. Following a review of mission objectives and the spacecraft configuration, design constraints on the pointing control system controlling the two-axis gimballed scan platform supporting the science instruments are discussed in relation to the scientific requirements of the mission. The primary design options considered for the pointing control system design for the baseline spacecraft are summarized, and the design selected, which employs a target-referenced, inertially stabilized control system, is described in detail. The four basic modes of operation of the pointing control subsystem (target acquisition, inertial hold, target track and slew) are discussed as they relate to operations at Halley and Tempel-2. It is pointed that the pointing control system design represents a significant advance in the state of the art of pointing controls for planetary missions.

  17. 76 FR 79676 - California Independent System Operator Corporation; Supplemental Notice of Agenda and Discussion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... Operator Corporation's (CAISO) proposal to eliminate convergence bidding at intertie scheduling points.\\1... proposal to eliminate convergence bidding at intertie scheduling points in detail. No formal presentations... 1973. For accessibility accommodations please send an email to [email protected] or call toll free...

  18. 77 FR 56115 - Drawbridge Operation Regulations; Fort Point Channel, Boston, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0815] Drawbridge Operation Regulations; Fort Point Channel, Boston, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has issued a temporary...

  19. Optical projectors simulate human eyes to establish operator's field of view

    NASA Technical Reports Server (NTRS)

    Beam, R. A.

    1966-01-01

    Device projects visual pattern limits of the field of view of an operator as his eyes are directed at a given point on a control panel. The device, which consists of two projectors, provides instant evaluation of visual ability at a point on a panel.

  20. 77 FR 40091 - Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating, Units 2 and 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-06

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247 and 50-286; NRC-2008-0672] Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating, Units 2 and 3 AGENCY: Nuclear Regulatory Commission... renewal of nuclear plants; availability. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC or the...

  1. 78 FR 26662 - Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Unit No. 3 Extension of Public...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-07

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-286; NRC-2013-0063] Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Unit No. 3 Extension of Public Comment Period AGENCY: Nuclear Regulatory... FURTHER INFORMATION CONTACT: Douglas V. Pickett, Senior Project Manager, Office of Nuclear Reactor...

  2. 49 CFR 1180.8 - Operational data.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... interchange points, using the corporate or political subdivision name of the points shown as well as the... crossings as a result of merger-related changes in operations or increases in rail traffic. (b) For major... plan changes, based on the impact analyses, that will result from the transaction, and their...

  3. 47 CFR 101.103 - Frequency coordination procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Assignment of frequencies will be made only in such a manner as to facilitate the rendition of communication...-point basis may not be extended or otherwise modified through the addition of point-to-point links. Such... modified through the addition of point-to-point links. Such operations licensed on a point-to-radius basis...

  4. 47 CFR 101.103 - Frequency coordination procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Assignment of frequencies will be made only in such a manner as to facilitate the rendition of communication...-point basis may not be extended or otherwise modified through the addition of point-to-point links. Such... modified through the addition of point-to-point links. Such operations licensed on a point-to-radius basis...

  5. 47 CFR 101.103 - Frequency coordination procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Assignment of frequencies will be made only in such a manner as to facilitate the rendition of communication...-point basis may not be extended or otherwise modified through the addition of point-to-point links. Such... modified through the addition of point-to-point links. Such operations licensed on a point-to-radius basis...

  6. LMJ Points Plus v2.6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos

    Short summary of the software's functionality: • built-in scan feature to acquire optical image of the surface to be analyzed • click-and-point selection of points of interest on the surface • supporting standalone autosampler/HPLC/MS operation: creating independent batch files after points of interests are selected for LEAPShell (autosampler control software from Leap Technologies) and Analyst® (mass spectrometry (MS) software from AB Sciex) • supporting integrated autosampler/HPLC/MS operation: creating one batch file for all instruments controlled by Analyst® (mass spectrometry software from AB Sciex) after points of interests are selected •creating heatmaps of analytes of interests from collected MS files inmore » a hand-off fashion« less

  7. Application of a Microcomputer to a Mobile Electric Power Plant.

    DTIC Science & Technology

    1980-05-28

    THE POINT OF ITS VARIFICATION. CONCLUSIONS ABOUT THE AIR POLLUTION AND FULL USAGE OF DIESEL AND GASOLINE POWERED TRIICKS ARE DRAWN FROM THE MODEL...and controller. Ideally, the diagnostics should pin point any faulty electrical or mechanical com- ponents and be performed while the AC-APU is in...over a portion of the operating range. Normally the operating point is placed just beyond the knee of the curve so that when higher flux is needed to

  8. Testing single point incremental forming molds for thermoforming operations

    NASA Astrophysics Data System (ADS)

    Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo

    2016-10-01

    Low pressure polymer processing processes as thermoforming or rotational molding use much simpler molds then high pressure processes like injection. However, despite the low forces involved with the process, molds manufacturing for this operations is still a very material, energy and time consuming operation. The goal of the research is to develop and validate a method for manufacturing plastically formed sheets metal molds by single point incremental forming (SPIF) operation for thermoforming operation. Stewart platform based SPIF machines allow the forming of thick metal sheets, granting the required structural stiffness for the mold surface, and keeping the short lead time manufacture and low thermal inertia.

  9. Perforation of the Right Ventricle Induced by Pulmonary Artery Catheter at Induction of Anesthesia for the Surgery for Liver Transplantation: A Case Report and Reviewed of Literature

    PubMed Central

    Auxiliadora-Martins, Maria; Apinagés dos Santos, Erick; Adans Wenzinger, Daniel; Alkmim-Teixeira, Gil Cezar; Neto, Gerardo Cristino de M.; Sankarankutty, Ajith Kumar; de Castro e Silva, Orlando; Martins-Filho, Olindo Assis; Basile-Filho, Anibal

    2009-01-01

    We report a case of a 45-year-old male patient diagnosed with liver cirrhosis by hepatitis C and alcohol, with a Child-Pugh score C and a model for end-stage liver disease (MELD) score of 27, and submitted to liver transplantation. The subject underwent insertion of the pulmonary artery catheter (PAC) in the right internal jugular vein, with technical difficulty concerning catheter advance. There was sudden hypotension, increase in central venous pressure (CVP), and decrease in SvO2 15 minutes after the PAC had been inserted, followed by cardiorespiratory arrest in pulseless electrical activity (PEA), which was promptly assisted with resuscitation. Pericardiocentesis was performed without success, so the individual was subjected to a subxiphoid pericardial window, which led to output of large amounts of blood as well as PEA reversal to sinus rhythm. Sternotomy was performed; rupture of the apex of the right ventricle (RV) was detected, and suture of the site was accomplished. After hemodynamic stabilization, the patient was transferred to the ICU, where he developed septic shock and, despite adequate therapy, died on the eighteenth day after ICU admission. PMID:20066172

  10. Crystal viscoplasticity model for the creep-fatigue interactions in single-crystal Ni-base superalloy CMSX-8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estrada Rodas, Ernesto A.; Neu, Richard W.

    A crystal viscoplasticity (CVP) model for the creep-fatigue interactions of nickel-base superalloy CMSX-8 is proposed. At the microstructure scale of relevance, the superalloys are a composite material comprised of a γ phase and a γ' strengthening phase with unique deformation mechanisms that are highly dependent on temperature. Considering the differences in the deformation of the individual material phases is paramount to predicting the deformation behavior of superalloys at a wide range of temperatures. In this work, we account for the relevant deformation mechanisms that take place in both material phases by utilizing two additive strain rates to model the deformationmore » on each material phase. The model is capable of representing the creep-fatigue interactions in single-crystal superalloys for realistic 3-dimensional components in an Abaqus User Material Subroutine (UMAT). Using a set of material parameters calibrated to superalloy CMSX-8, the model predicts creep-fatigue, fatigue and thermomechanical fatigue behavior of this single-crystal superalloy. In conclusion, a sensitivity study of the material parameters is done to explore the effect on the deformation due to changes in the material parameters relevant to the microstructure.« less

  11. Crystal viscoplasticity model for the creep-fatigue interactions in single-crystal Ni-base superalloy CMSX-8

    DOE PAGES

    Estrada Rodas, Ernesto A.; Neu, Richard W.

    2017-09-11

    A crystal viscoplasticity (CVP) model for the creep-fatigue interactions of nickel-base superalloy CMSX-8 is proposed. At the microstructure scale of relevance, the superalloys are a composite material comprised of a γ phase and a γ' strengthening phase with unique deformation mechanisms that are highly dependent on temperature. Considering the differences in the deformation of the individual material phases is paramount to predicting the deformation behavior of superalloys at a wide range of temperatures. In this work, we account for the relevant deformation mechanisms that take place in both material phases by utilizing two additive strain rates to model the deformationmore » on each material phase. The model is capable of representing the creep-fatigue interactions in single-crystal superalloys for realistic 3-dimensional components in an Abaqus User Material Subroutine (UMAT). Using a set of material parameters calibrated to superalloy CMSX-8, the model predicts creep-fatigue, fatigue and thermomechanical fatigue behavior of this single-crystal superalloy. In conclusion, a sensitivity study of the material parameters is done to explore the effect on the deformation due to changes in the material parameters relevant to the microstructure.« less

  12. A rational approach to fluid therapy in sepsis.

    PubMed

    Marik, P; Bellomo, R

    2016-03-01

    Aggressive fluid resuscitation to achieve a central venous pressure (CVP) greater than 8 mm Hg has been promoted as the standard of care, in the management of patients with severe sepsis and septic shock. However recent clinical trials have demonstrated that this approach does not improve the outcome of patients with severe sepsis and septic shock. Pathophysiologically, sepsis is characterized by vasoplegia with loss of arterial tone, venodilation with sequestration of blood in the unstressed blood compartment and changes in ventricular function with reduced compliance and reduced preload responsiveness. These data suggest that sepsis is primarily not a volume-depleted state and recent evidence demonstrates that most septic patients are poorly responsive to fluids. Furthermore, almost all of the administered fluid is sequestered in the tissues, resulting in severe oedema in vital organs and, thereby, increasing the risk of organ dysfunction. These data suggest that a physiologic, haemodynamically guided conservative approach to fluid therapy in patients with sepsis would be prudent and would likely reduce the morbidity and improve the outcome of this disease. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. [Comparison of the effect of fluid resuscitation as guided either by lactate clearance rate or by central venous oxygen saturation in patients with sepsis].

    PubMed

    Yu, Bin; Tian, Hui-yan; Hu, Zhen-jie; Zhao, Chai; Liu, Li-xia; Zhang, Yong; Zhu, Gui-jun; Wang, Lan-tao; Wu, Xin-hui; Li, Juan

    2013-10-01

    To compare the efficacy of fluid resuscitation as guided by lactate clearance rate (LCR) and central venous oxygen saturation (ScvO2) in patients with sepsis. A prospective randomized control study was conducted. Fifty patients diagnosed with severe sepsis or septic shock from January 2011 to February 2012 in department of critical care medicine of Fourth Hospital of Hebei Medical University were enrolled in the study. The patients were randomly divided into two groups according to the sequence (each n=25): ScvO2 group and LCR group. After ICU admission, the patients were treated symptomatically timely, and fluid resuscitation was started as early as possible according to Surviving Sepsis Campaign guidance for management of severe sepsis and septic shock 2008. Central venous pressure (CVP)≥8 mm Hg (1 mm Hg=0.133 kPa), mean arterial pressure (MAP)≥65 mm Hg and ScvO2≥0.70 served as goal values to accomplish the fluid resuscitation therapy in ScvO2 group, while CVP≥8 mm Hg, MAP≥65 mm Hg, LCR≥10% served as goal value to accomplish the fluid resuscitation therapy in LCR group. The general condition and clinical characteristics on arrival in ICU, changes in CVP, MAP, ScvO2, lactate level and/or LCR before (0 hour) and 3, 6, 72 hours after the start of fluid resuscitation and the other related conditions during the therapy were recorded. There was no significant difference in general data or clinical characteristics before the start of therapy, occurrence of organ dysfunction, or treatment measures during different time periods after start of fluid resuscitation. Compared with the condition immediately before fluid resuscitation, at 3 hours after start of fluid resuscitation, CVP were improved in LCR and ScvO2 groups (8.58±1.17 mm Hg vs. 6.33±1.21 mm Hg, 9.08±2.43 mm Hg vs. 5.33±0.98 mm Hg, both P<0.05); at 6 hours after start of fluid resuscitation, heart rate (HR) and respiratory rate (RR) were lowered in LCR and ScvO2 groups (HR: 96±18 bpm vs. 127±13 bpm, 98±13 bpm vs. 116±19 bpm, RR: 23±3 times/min vs. 33±9 times/min, 24±5 times/min vs. 35±6 times/min, all P<0.05), oxygenation index (PaO2/FiO2) was increased in LCR and ScvO2 groups (179±41 mm Hg vs. 86±21 mm Hg, 202±33 mm Hg vs. 95±17 mm Hg, both P<0.05), and there was no significant difference in MAP in both groups. There was no significant difference in all indexes between two groups. In LCR group, 3 hours after start of fluid resuscitation, lactate level was significantly decreased (2.81±0.18 mmol/L vs. 3.43±1.31 mmol/L, P<0.05). Compared with the value 3 hours after start of fluid resuscitation, LCR was significantly improved at 6 hours and 72 hours after start of fluid resuscitation in LCR group [(42.69±8.75)%, (48.87±9.69)% vs. (20.32±4.58)%, both P<0.05]. Compared with that immediately before fluid resuscitation, ScvO2 was significant improved in ScvO2 group at 3 hours after start of fluid resuscitation (0.65±0.04 vs. 0.53±0.06, P<0.05). There was no significant difference in success rate of fluid resuscitation comparing that of 6 hours and that of 72 hours [6 hours: 72% (18/25) vs. 64% (16/25), χ(2)=0.368, P=0.762; 72 hours: 88% (22/25) vs. 88% (22/25) ,χ(2)=0.000, P=1.000], length of ICU stay (8±3 days vs. 10±4 days, t=0.533, P=0.874), length of hospital stay (29±11 days vs. 35±16 days, t=0.692, P=0.531), improvement rate [84% (21/25) vs. 76%(19/25), χ(2)=0.500, P=0.480] or 28-day mortality [20% (5/25) vs. 28% (7/25), χ(2)=0.439, P=0.742] between LCR and ScvO2 groups. Both LCR and ScvO2 can be taken as the index in confirming the endpoint of fluid resuscitation for patients with severe sepsis and septic shock. Fluid resuscitation therapy under the guidance of LCR is accurate and reliable in patients with severe sepsis and septic shock.

  14. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  15. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  16. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  17. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  18. 49 CFR 236.306 - Facing point lock or switch-and-lock movement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...

  19. Entropy Stable Staggered Grid Spectral Collocation for the Burgers' and Compressible Navier-Stokes Equations

    NASA Technical Reports Server (NTRS)

    Carpenter, Mark H.; Parsani, Matteo; Fisher, Travis C.; Nielsen, Eric J.

    2015-01-01

    Staggered grid, entropy stable discontinuous spectral collocation operators of any order are developed for Burgers' and the compressible Navier-Stokes equations on unstructured hexahedral elements. This generalization of previous entropy stable spectral collocation work [1, 2], extends the applicable set of points from tensor product, Legendre-Gauss-Lobatto (LGL) to a combination of tensor product Legendre-Gauss (LG) and LGL points. The new semi-discrete operators discretely conserve mass, momentum, energy and satisfy a mathematical entropy inequality for both Burgers' and the compressible Navier-Stokes equations in three spatial dimensions. They are valid for smooth as well as discontinuous flows. The staggered LG and conventional LGL point formulations are compared on several challenging test problems. The staggered LG operators are significantly more accurate, although more costly to implement. The LG and LGL operators exhibit similar robustness, as is demonstrated using test problems known to be problematic for operators that lack a nonlinearly stability proof for the compressible Navier-Stokes equations (e.g., discontinuous Galerkin, spectral difference, or flux reconstruction operators).

  20. Operation PLUMBBOB. Summary Report, Test Group 57, Nevada Test Site. Extracted Version

    DTIC Science & Technology

    1982-06-04

    numnber) Operation PI*;UMBDOo lest Group 57 conducted a one- point detonation for the purpose of studying hazards from acci- dents. The objectives were...I ! i - 5-6 ABSTRACT On April 24, 1957, Operation Plumbbob Test Group 57 conducted a one- point detonation Ifor the purpose of studying...Plot of Air Sampler Array. 54 4.5 Staplex Air Sampler With Adapter Head . 55 4. 6 Staplex Air Sampler With Annular Impactor 56 13 ILLUSTRATIONS

  1. Application of inertial instruments for DSN antenna pointing and tracking

    NASA Technical Reports Server (NTRS)

    Eldred, D. B.; Nerheim, N. M.; Holmes, K. G.

    1990-01-01

    The feasibility of using inertial instruments to determine the pointing attitude of the NASA Deep Space Network antennas is examined. The objective is to obtain 1 mdeg pointing knowledge in both blind pointing and tracking modes to facilitate operation of the Deep Space Network 70 m antennas at 32 GHz. A measurement system employing accelerometers, an inclinometer, and optical gyroscopes is proposed. The initial pointing attitude is established by determining the direction of the local gravity vector using the accelerometers and the inclinometer, and the Earth's spin axis using the gyroscopes. Pointing during long-term tracking is maintained by integrating the gyroscope rates and augmenting these measurements with knowledge of the local gravity vector. A minimum-variance estimator is used to combine measurements to obtain the antenna pointing attitude. A key feature of the algorithm is its ability to recalibrate accelerometer parameters during operation. A survey of available inertial instrument technologies is also given.

  2. System for controlling the operating temperature of a fuel cell

    DOEpatents

    Fabis, Thomas R.; Makiel, Joseph M.; Veyo, Stephen E.

    2006-06-06

    A method and system are provided for improved control of the operating temperature of a fuel cell (32) utilizing an improved temperature control system (30) that varies the flow rate of inlet air entering the fuel cell (32) in response to changes in the operating temperature of the fuel cell (32). Consistent with the invention an improved temperature control system (30) is provided that includes a controller (37) that receives an indication of the temperature of the inlet air from a temperature sensor (39) and varies the heat output by at least one heat source (34, 36) to maintain the temperature of the inlet air at a set-point T.sub.inset. The controller (37) also receives an indication of the operating temperature of the fuel cell (32) and varies the flow output by an adjustable air mover (33), within a predetermined range around a set-point F.sub.set, in order to maintain the operating temperature of the fuel cell (32) at a set-point T.sub.opset.

  3. 34 CFR 366.15 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (4) The benefits to be gained by meeting those needs. (c) Plan of operation (15 points). The Secretary reviews each application for information that shows the quality of the plan of operation for the... origin, gender, age, or disability. (d) Quality of key personnel (7 points). (1) The Secretary reviews...

  4. 34 CFR 366.15 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (4) The benefits to be gained by meeting those needs. (c) Plan of operation (15 points). The Secretary reviews each application for information that shows the quality of the plan of operation for the... origin, gender, age, or disability. (d) Quality of key personnel (7 points). (1) The Secretary reviews...

  5. 34 CFR 366.15 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (4) The benefits to be gained by meeting those needs. (c) Plan of operation (15 points). The Secretary reviews each application for information that shows the quality of the plan of operation for the... origin, gender, age, or disability. (d) Quality of key personnel (7 points). (1) The Secretary reviews...

  6. 34 CFR 644.21 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... period and the project period given the project budget and other resources. (c) Plan of operation (30 points). The Secretary evaluates the quality of the applicant's plan of operation on the basis of the... their participation without regard to race, color, national origin, gender, or disability; (3) (2 points...

  7. 34 CFR 366.15 - What selection criteria does the Secretary use?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (4) The benefits to be gained by meeting those needs. (c) Plan of operation (15 points). The Secretary reviews each application for information that shows the quality of the plan of operation for the... origin, gender, age, or disability. (d) Quality of key personnel (7 points). (1) The Secretary reviews...

  8. 76 FR 79066 - Drawbridge Operation Regulation; Escatawpa River, Moss Point, MS

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-1082] Drawbridge Operation Regulation; Escatawpa River, Moss Point, MS AGENCY: Coast Guard, DHS. ACTION: Notice of temporary...-2011-1082 and are available online by going to http://www.regulations.gov , inserting USCG-2011-1082 in...

  9. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  10. Using Powerpoint Animations to Teach Operations Management Techniques and Concepts

    ERIC Educational Resources Information Center

    Treleven, Mark D.; Penlesky, Richard J.; Callarman, Thomas E.; Watts, Charles A.; Bragg, Daniel J.

    2014-01-01

    This article examines the value of using complex animated PowerPoint presentations to teach operations management techniques and concepts. To provide context, literature covering the use of PowerPoint animations in business education is briefly reviewed. The specific animations employed in this study are identified and their expected benefits to…

  11. Linearization: Students Forget the Operating Point

    ERIC Educational Resources Information Center

    Roubal, J.; Husek, P.; Stecha, J.

    2010-01-01

    Linearization is a standard part of modeling and control design theory for a class of nonlinear dynamical systems taught in basic undergraduate courses. Although linearization is a straight-line methodology, it is not applied correctly by many students since they often forget to keep the operating point in mind. This paper explains the topic and…

  12. 10 CFR 435.304 - The COSTSAFR Program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) operates on a micro-computer system that uses the MS DOS operating system and is equipped with an 8087 co... (Version 3.0) also prints out a point system that identifies a wide array of different energy conservation... goal and the point system in the design and procurement procedures so that designers and builders can...

  13. 10 CFR 435.304 - The COSTSAFR Program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) operates on a micro-computer system that uses the MS DOS operating system and is equipped with an 8087 co... (Version 3.0) also prints out a point system that identifies a wide array of different energy conservation... goal and the point system in the design and procurement procedures so that designers and builders can...

  14. 10 CFR 435.304 - The COSTSAFR Program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) operates on a micro-computer system that uses the MS DOS operating system and is equipped with an 8087 co... (Version 3.0) also prints out a point system that identifies a wide array of different energy conservation... goal and the point system in the design and procurement procedures so that designers and builders can...

  15. 10 CFR 435.304 - The COSTSAFR Program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) operates on a micro-computer system that uses the MS DOS operating system and is equipped with an 8087 co... (Version 3.0) also prints out a point system that identifies a wide array of different energy conservation... goal and the point system in the design and procurement procedures so that designers and builders can...

  16. 10 CFR 435.304 - The COSTSAFR Program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) operates on a micro-computer system that uses the MS DOS operating system and is equipped with an 8087 co... (Version 3.0) also prints out a point system that identifies a wide array of different energy conservation... goal and the point system in the design and procurement procedures so that designers and builders can...

  17. 78 FR 39018 - Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 2 and 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-28

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247 and 50-286; NRC-2008-0672] Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 2 and 3 AGENCY: Nuclear Regulatory Commission... Renewal of Nuclear Plants; issuance. SUMMARY: Notice is hereby given that the U.S. Nuclear Regulatory...

  18. 78 FR 37591 - Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point Unit 2, LLC, Issuance of Director...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0284; Docket No. 50-247; License No. DPR-26] Entergy Nuclear Operations, Inc., Entergy Nuclear Indian Point Unit 2, LLC, Issuance of Director's Decision Notice is hereby given that the Deputy Director, Reactor Safety Programs, Office of Nuclear Reactor...

  19. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  20. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  1. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  2. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  3. Microprocessor-controlled step-down maximum-power-point tracker for photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Mazmuder, R. K.; Haidar, S.

    1992-12-01

    An efficient maximum power point tracker (MPPT) has been developed and can be used with a photovoltaic (PV) array and a load which requires lower voltage than the PV array voltage to be operated. The MPPT makes the PV array to operate at maximum power point (MPP) under all insolation and temperature, which ensures the maximum amount of available PV power to be delivered to the load. The performance of the MPPT has been studied under different insolation levels.

  4. Catalog of Existing Small Tools for Surface Preparation and Support Equipment for Blasters and Painters

    DTIC Science & Technology

    1977-05-01

    128 lbs./ft3 Specific Gravity 3.6 Hardness (MOHS) 7 Melting Point 2900°F. Coefficient of Expansion 7 . 8 X 1 0– 6 FIGURE 3.17: Properties of...Beaumont, Texas Bethlehem Steel Corporation, San Francisco, California Bethlehem Steel Corporation, Sparrows Point , Maryland Jacksonville Shipyards...checklist can be used by operators and super- visors as a starting point for determining if the yard’s abrasive blasting facility is operating at full

  5. A study to assess the influence of interprofessional point of care simulation training on safety culture in the operating theatre environment of a university teaching hospital.

    PubMed

    Hinde, Theresa; Gale, Thomas; Anderson, Ian; Roberts, Martin; Sice, Paul

    2016-01-01

    Interprofessional point of care or in situ simulation is used as a training tool in our operating theatre directorate with the aim of improving crisis behaviours. This study aimed to assess the impact of interprofessional point of care simulation on the safety culture of operating theatres. A validated Safety Attitude Questionnaire was administered to staff members before each simulation scenario and then re-administered to the same staff members after 6-12 months. Pre- and post-training Safety Attitude Questionnaire-Operating Room (SAQ-OR) scores were compared using paired sample t-tests. Analysis revealed a statistically significant perceived improvement in both safety (p < 0.001) and teamwork (p = 0.013) climate scores (components of safety culture) 6-12 months after interprofessional simulation training. A growing body of literature suggests that a positive safety culture is associated with improved patient outcomes. Our study supports the implementation of point of care simulation as a useful intervention to improve safety culture in theatres.

  6. Dispatching packets on a global combining network of a parallel computer

    DOEpatents

    Almasi, Gheorghe [Ardsley, NY; Archer, Charles J [Rochester, MN

    2011-07-19

    Methods, apparatus, and products are disclosed for dispatching packets on a global combining network of a parallel computer comprising a plurality of nodes connected for data communications using the network capable of performing collective operations and point to point operations that include: receiving, by an origin system messaging module on an origin node from an origin application messaging module on the origin node, a storage identifier and an operation identifier, the storage identifier specifying storage containing an application message for transmission to a target node, and the operation identifier specifying a message passing operation; packetizing, by the origin system messaging module, the application message into network packets for transmission to the target node, each network packet specifying the operation identifier and an operation type for the message passing operation specified by the operation identifier; and transmitting, by the origin system messaging module, the network packets to the target node.

  7. 47 CFR 101.101 - Frequency availability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...

  8. 47 CFR 101.101 - Frequency availability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...

  9. 47 CFR 101.21 - Technical content of applications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical... Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's name and address. Transmitting station...

  10. 47 CFR 101.21 - Technical content of applications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical... Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's name and address. Transmitting station...

  11. 47 CFR 101.101 - Frequency availability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...

  12. Arctic Atmospheric Measurements Using Manned and Unmanned Aircraft, Tethered Balloons, and Ground-Based Systems at U.S. DOE ARM Facilities on the North Slope Of Alaska

    NASA Astrophysics Data System (ADS)

    Ivey, M.; Dexheimer, D.; Roesler, E. L.; Hillman, B. R.; Hardesty, J. O.

    2016-12-01

    The U.S. Department of Energy (DOE) provides scientific infrastructure and data to the international Arctic research community via research sites located on the North Slope of Alaska and an open data archive maintained by the ARM program. In 2016, DOE continued investments in improvements to facilities and infrastructure at Oliktok Point Alaska to support operations of ground-based facilities and unmanned aerial systems for science missions in the Arctic. The Third ARM Mobile Facility, AMF3, now deployed at Oliktok Point, was further expanded in 2016. Tethered instrumented balloons were used at Oliktok to make measurements of clouds in the boundary layer including mixed-phase clouds and to compare measurements with those from the ground and from unmanned aircraft operating in the airspace above AMF3. The ARM facility at Oliktok Point includes Special Use Airspace. A Restricted Area, R-2204, is located at Oliktok Point. Roughly 4 miles in diameter, it facilitates operations of tethered balloons and unmanned aircraft. R-2204 and a new Warning Area north of Oliktok, W-220, are managed by Sandia National Laboratories for DOE Office of Science/BER. These Special Use Airspaces have been successfully used to launch and operate unmanned aircraft over the Arctic Ocean and in international airspace north of Oliktok Point.A steady progression towards routine operations of unmanned aircraft and tethered balloon systems continues at Oliktok. Small unmanned aircraft (DataHawks) and tethered balloons were successfully flown at Oliktok starting in June of 2016. This poster will discuss how principal investigators may apply for use of these Special Use Airspaces, acquire data from the Third ARM Mobile Facility, or bring their own instrumentation for deployment at Oliktok Point, Alaska.

  13. Early Mission Maneuver Operations for the Deep Space Climate Observatory Sun-Earth L1 Libration Point Mission

    NASA Technical Reports Server (NTRS)

    Roberts, Craig; Case, Sara; Reagoso, John; Webster, Cassandra

    2015-01-01

    The Deep Space Climate Observatory mission launched on February 11, 2015, and inserted onto a transfer trajectory toward a Lissajous orbit around the Sun-Earth L1 libration point. This paper presents an overview of the baseline transfer orbit and early mission maneuver operations leading up to the start of nominal science orbit operations. In particular, the analysis and performance of the spacecraft insertion, mid-course correction maneuvers, and the deep-space Lissajous orbit insertion maneuvers are discussed, com-paring the baseline orbit with actual mission results and highlighting mission and operations constraints..

  14. [Total knee arthroplasty by lateral parapatellar approach for valgus knee].

    PubMed

    Zhou, Dian-ge; Zhang, Bin; Kou, Bo-long; Lü, Hou-shan

    2007-07-17

    To investigate the effect of lateral parapatellar approach in total knee arthroplasty (TKA) of valgus knee. Lateral parapatellar approach of total knee arthroplasty was applied in 8 patients (10 knees) with severe valgus osteoarthritis knee (bilateral in 2 cases and unilateral in 6 cases), with the valgus angle > 15 degrees , 1 male (1 knee) and 7 females (9 knee), aged 68.2 (58 - 79), 7 cases (9 knees) being of the Krackow type I and 1 case (1 knee) of the Krackow type I, I. After incision of the skin through lateral knee, ilio-tibial band was prolonged by apple pie arthroplasty. The joint capsule was cut open laterally 2 - 4 cm from the para-patellar edge. Soft tissue balance was performed by releasing I - T band in Gerdy tubercle, lateral collateral ligament and poster-lateral capsule from the femur and tibial side. Valgus angle of distal femur cutting were five degree. Whiteside line and trans-epicondylar line were used as AP rotational cutting reference. All patellar of the group were resurfaced. Capsule closure is completed with the knee flexed. The expanded deep lateral soft tissue sleeve (coronal Z-plasty) is sutured with the medial retinaculum sleeve (superficial layer). Follow-up was conducted for 19.6 months (1 - 51 months). Seven cases (9 knees) were replaced by posterior stabilized cemented prostheses (TC-Dynamic, PLUS), one case (1 knee) was replaced by RT prosthesis (RT-PLUS(TM) Solution, PLUS). After operation, the valgus deformity of all patients was corrected and all patients could walk 100 m with or without the help of walking holders. The average range of motion (ROM) was improved from the pre-operative. 95.6 degrees (85 degrees - 110 degrees ) to the post-operative 117.1 degrees (100 degrees - 125 degrees ). The average femorotibial angle (FTA) was corrected from the pre-operative. 27.6 degrees (20 degrees - 40 degrees ) to the post-operative 6.8 degrees (5 degrees - 9 degrees ). The Knee Score System (KSS) score and functional score were improved from the pre-operative 22.7 points (9 - 48 points) and 26.5 points (12 - 55 points) to the post-operative 86.4 points (85 - 95 points) and 89.1 points (80 - 95 points) respectively. Follow-up showed that the FTA remained unchanged and the knee stability of all patients was good. Through lateral approach, "Z" plasty of the capsule can release the lateral structure and decrease the pressure of common peroneal nerve. For TKR with moderate to severe fixed valgus knee, lateral approach is an effective way to correct the deformity.

  15. Solution of the effective Hamiltonian of impurity hopping between two sites in a metal

    NASA Astrophysics Data System (ADS)

    Ye, Jinwu

    1997-07-01

    We analyze in detail all the possible fixed points of the effective Hamiltonian of a nonmagnetic impurity hopping between two sites in a metal obtained by Moustakas and Fisher (MF). We find a line of non-Fermi liquid fixed points which continuously interpolates between the two-channel Kondo fixed point (2CK) and the one-channel, two-impurity Kondo (2IK) fixed point. There is one relevant direction with scaling dimension 12 and one leading irrelevant operator with dimension 32. There is also one marginal operator in the spin sector moving along this line. The marginal operator, combined with the leading irrelevant operator, will generate the relevant operator. For the general position on this line, the leading low-temperature exponents of the specific heat, the hopping susceptibility and the electron conductivity Cimp,χhimp,σ(T) are the same as those of the 2CK, but the finite-size spectrum depends on the position on the line. No universal ratios can be formed from the amplitudes of the three quantities except at the 2CK point on this line where the universal ratios can be formed. At the 2IK point on this line, σ(T)~2σu(1+aT3/2), no universal ratio can be formed either. The additional non-Fermi-liquid fixed point found by MF has the same symmetry as the 2IK, it has two relevant directions with scaling dimension 12, and is therefore also unstable. The leading low-temperature behaviors are Cimp~T,χhimp~lnT,σ(T)~2σu(1+aT3/2) no universal ratios can be formed. The system is shown to flow to a line of Fermi-liquid fixed points which continuously interpolates between the noninteracting fixed point and the two-channel spin-flavor Kondo fixed point discussed by the author previously. The effect of particle-hole symmetry breaking is discussed. The effective Hamiltonian in the external magnetic field is analyzed. The scaling functions for the physical measurable quantities are derived in the different regimes; their predictions for the experiments are given. Finally the implications are given for a nonmagnetic impurity hopping around three sites with triangular symmetry discussed by MF.

  16. Fine pointing control for free-space optical communication

    NASA Technical Reports Server (NTRS)

    Portillo, A. A.; Ortiz, G. G.; Racho, C.

    2000-01-01

    Free-Space Optical Communications requires precise, stable laser pointing to maintain operating conditions. This paper also describes the software and hardware implementation of Fine Pointing Control based on the Optical Communications Demonstrator architecture.

  17. Orbital operations with the Shuttle Infrared Telescope Facility /SIRTF/

    NASA Technical Reports Server (NTRS)

    Werner, M. W.; Lorell, K. R.

    1981-01-01

    The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically-cooled, 1-m-class telescope that will be operated from the Space Shuttle as an observatory for infrared astronomy. This paper discusses the scientific constraints on and the requirements for pointing and controlling SIRTF as well as several aspects of SIRTF orbital operations. The basic pointing requirement is for an rms stability of 0.25 arcsec, which is necessary to realize the full angular resolution of the 5-micron diffraction-limited SIRTF. Achieving this stability requires the use of hardware and software integral to SIRTF working interactively with the gyrostabilized Shuttle pointing-mount. The higher sensitivity of SIRTF, together with orbital and time constraints, puts a premium on rapid target acquisition and on efficient operational and observational procedures. Several possible acquisition modes are discussed, and the importance of source acquisition by maximizing the output of an infrared detector is emphasized.

  18. Operation condition for continuous anti-solvent crystallization of CBZ-SAC cocrystal considering deposition risk of undesired crystals

    NASA Astrophysics Data System (ADS)

    Nishimaru, Momoko; Nakasa, Miku; Kudo, Shoji; Takiyama, Hiroshi

    2017-07-01

    Crystallization operation of cocrystal production has deposition risk of undesired crystals. Simultaneously, continuous manufacturing processes are focused on. In this study, conditions for continuous cocrystallization considering risk reduction of undesired crystals deposition were investigated on the view point of thermodynamics and kinetics. The anti-solvent cocrystallization was carried out in four-component system of carbamazepine, saccharin, methanol and water. From the preliminary batch experiment, the relationships among undesired crystal deposition, solution composition decided by mixing ratio of solutions, and residence time for the crystals were considered, and then the conditions of continuous experiment were decided. Under these conditions, the continuous experiment was carried out. The XRD patterns of obtained crystals in the continuous experiment showed that desired cocrystals were obtained without undesired crystals. This experimental result was evaluated by using multi-component phase diagrams from the view point of the operation point's movement. From the evaluation, it was found that there is a certain operation condition which the operation point is fixed with time in the specific domain without the deposition risk of undesired single component crystals. It means the possibility of continuous production of cocrystals without deposition risk of undesired crystals was confirmed by using multi-component phase diagrams.

  19. [Microeconomics of introduction of a PET system based on the revised Japanese National Insurance reimbursement system].

    PubMed

    Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi

    2003-11-01

    It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.

  20. Stability analysis of BWR nuclear-coupled thermal-hyraulics using a simple model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karve, A.A.; Rizwan-uddin; Dorning, J.J.

    1995-09-01

    A simple mathematical model is developed to describe the dynamics of the nuclear-coupled thermal-hydraulics in a boiling water reactor (BWR) core. The model, which incorporates the essential features of neutron kinetics, and single-phase and two-phase thermal-hydraulics, leads to simple dynamical system comprised of a set of nonlinear ordinary differential equations (ODEs). The stability boundary is determined and plotted in the inlet-subcooling-number (enthalpy)/external-reactivity operating parameter plane. The eigenvalues of the Jacobian matrix of the dynamical system also are calculated at various steady-states (fixed points); the results are consistent with those of the direct stability analysis and indicate that a Hopf bifurcationmore » occurs as the stability boundary in the operating parameter plane is crossed. Numerical simulations of the time-dependent, nonlinear ODEs are carried out for selected points in the operating parameter plane to obtain the actual damped and growing oscillations in the neutron number density, the channel inlet flow velocity, and the other phase variables. These indicate that the Hopf bifurcation is subcritical, hence, density wave oscillations with growing amplitude could result from a finite perturbation of the system even where the steady-state is stable. The power-flow map, frequently used by reactor operators during start-up and shut-down operation of a BWR, is mapped to the inlet-subcooling-number/neutron-density (operating-parameter/phase-variable) plane, and then related to the stability boundaries for different fixed inlet velocities corresponding to selected points on the flow-control line. The stability boundaries for different fixed inlet subcooling numbers corresponding to those selected points, are plotted in the neutron-density/inlet-velocity phase variable plane and then the points on the flow-control line are related to their respective stability boundaries in this plane.« less

  1. 49 CFR 236.103 - Switch circuit controller or point detector.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch circuit controller or point detector. 236.103 Section 236.103 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... controller or point detector. Switch circuit controller, circuit controller, or point detector operated by...

  2. 49 CFR 236.103 - Switch circuit controller or point detector.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch circuit controller or point detector. 236.103 Section 236.103 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... controller or point detector. Switch circuit controller, circuit controller, or point detector operated by...

  3. 49 CFR 236.103 - Switch circuit controller or point detector.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch circuit controller or point detector. 236.103 Section 236.103 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... controller or point detector. Switch circuit controller, circuit controller, or point detector operated by...

  4. 49 CFR 236.103 - Switch circuit controller or point detector.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch circuit controller or point detector. 236.103 Section 236.103 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... controller or point detector. Switch circuit controller, circuit controller, or point detector operated by...

  5. 49 CFR 236.103 - Switch circuit controller or point detector.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch circuit controller or point detector. 236.103 Section 236.103 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... controller or point detector. Switch circuit controller, circuit controller, or point detector operated by...

  6. 47 CFR 101.21 - Technical content of applications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...

  7. 47 CFR 101.5 - Station authorization required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...

  8. 47 CFR 101.5 - Station authorization required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...

  9. 47 CFR 101.21 - Technical content of applications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...

  10. 47 CFR 101.21 - Technical content of applications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...

  11. 47 CFR 101.5 - Station authorization required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...

  12. 47 CFR 101.5 - Station authorization required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...

  13. 47 CFR 101.5 - Station authorization required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...

  14. Experiment Comparison between Engineering Acid Dew Point and Thermodynamic Acid Dew Point

    NASA Astrophysics Data System (ADS)

    Song, Jinghui; Yuan, Hui; Deng, Jianhua

    2018-06-01

    in order to realize the accurate prediction of acid dew point, a set of measurement system of acid dew point for the flue gas flue gas in the tail of the boiler was designed and built, And measured at the outlet of an air preheater of a power plant of 1 000 MW, The results show that: Under the same conditions, with the test temperature decreases, Nu of heat transfer tubes, fouling and corrosion of pipe wall and corrosion pieces gradually deepened. Then, the measured acid dew point is compared with the acid dew point obtained by using the existing empirical formula under the same coal type. The dew point of engineering acid is usually about 40 ° lower than the dew point of thermodynamic acid because of the coupling effect of fouling on the acid liquid, which can better reflect the actual operation of flue gas in engineering and has certain theoretical guidance for the design and operation of deep waste heat utilization system significance.

  15. Impact of large volume paracentesis on respiratory parameters including transpulmonary pressure and on transpulmonary thermodilution derived hemodynamics: A prospective study

    PubMed Central

    Mayr, Ulrich; Karsten, Eugen; Lahmer, Tobias; Rasch, Sebastian; Thies, Philipp; Henschel, Benedikt; Fischer, Gerrit; Schmid, Roland M.

    2018-01-01

    Introduction Appropriate mechanical ventilation and prevention of alveolar collaps is mainly dependent on transpulmonary pressure TPP. TPP is assessed by measurement of esophageal pressure EP, largely influenced by pleural and intraabdominal pressure IAP. Consecutively, TPP-guided ventilation might be particularly useful in patients with high IAP. This study investigates the impact of large volume paracentesis LVP on TPP, EP, IAP as well as on hemodynamic and respiratory function in patients with liver cirrhosis and tense ascites. Material and methods We analysed 23 LVP-procedures in 11 cirrhotic patients ventilated with the AVEA Viasys respirator (CareFusion, USA) which is capable to measure EP via an esophageal tube. Results LVP of a mean volume of 4826±1276 mL of ascites resulted in marked increases in inspiratory (17.9±8.9 vs. 5.4±13.3 cmH2O; p<0.001) as well as expiratory TPP (-3.0±4.7 vs. -15.9±10.9 cmH2O; p<0.001; primary endpoint). In parallel, the inspiratory (2.4±8.7 vs. 14.1±14.5 cmH2O; p<0.001) and expiratory EP (12.4±6.0 vs. 24.9±11.3 cmH2O; p<0.001) significantly decreased. The effects were most pronounced for the release of the first 500 mL of ascites. LVP evoked substantial decreases in IAP and central venous pressure CVP. By contrast, mean arterial pressure, cardiac index, global end-diastolic volume index, extravascular lung water index and systemic vascular resistance index did not change. Among the respiratory parameters we observed an increase in paO2/FiO2 (247.7±60.9 vs. 208.3±46.8 mmHg; p<0.001) and a decrease in Oxygenation Index OI (4.8±2.0 vs. 5.8±3.1 cmH2O/mmHg; p = 0.002). Tidal volume (510±100 vs. 452±113 mL; p = 0.008) and dynamic respiratory system compliance Cdyn (46.8±15.9 vs. 35.1±14.6 mL/cmH20; p<0.001) increased, whereas paCO2 (47.3±10.7 vs. 51.2±12.3mmHg; p = 0.046) and the respiratory rate decreased (17.1±7.3 vs. 19.6±7.8 min-1; p = 0.010). Conclusions In mechanically ventilated patients with decompensated cirrhosis, intraabdominal hypertension resulted in a substantially decreased TPP despite PEEP-setting according to the ARDSNet. In these patients LVP markedly increased TPP and improved respiratory function in parallel with a decline of EP. Furthermore, LVP induced a decrease in IAP and CVP, while other hemodynamic parameters did not change. PMID:29538440

  16. 40 CFR 63.745 - Standards: Primer and topcoat application operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system requirements. Each control system shall reduce the operation's organic HAP and VOC emissions to... control system that meets or exceeds the efficiency data points in Tables 1 and 2 of this section and is... pollution control system that meets or exceeds the efficiency data points in Tables 3 and 4 of this section...

  17. 40 CFR 63.745 - Standards: Primer and topcoat application operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... system requirements. Each control system shall reduce the operation's organic HAP and VOC emissions to... control system that meets or exceeds the efficiency data points in Tables 1 and 2 of this section and is... pollution control system that meets or exceeds the efficiency data points in Tables 3 and 4 of this section...

  18. 40 CFR 63.745 - Standards: Primer and topcoat application operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... system requirements. Each control system shall reduce the operation's organic HAP and VOC emissions to... control system that meets or exceeds the efficiency data points in Tables 1 and 2 of this section and is... pollution control system that meets or exceeds the efficiency data points in Tables 3 and 4 of this section...

  19. 40 CFR 63.745 - Standards: Primer and topcoat application operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system requirements. Each control system shall reduce the operation's organic HAP and VOC emissions to... control system that meets or exceeds the efficiency data points in Tables 1 and 2 of this section and is... pollution control system that meets or exceeds the efficiency data points in Tables 3 and 4 of this section...

  20. Animated Powerpoint Presentations for Teaching Operations and Supply Chain Management: Perceived Value and Electronic Exchange of Files

    ERIC Educational Resources Information Center

    Treleven, Mark D.; Penlesky, Richard J.; Callarman, Thomas E.; Watts, Charles A.; Bragg, Daniel J.

    2012-01-01

    This paper presents the innovation of sharing animated PowerPoint presentations used in teaching operations and supply chain management techniques and concepts through an international electronic exchange. The plan for the exchange is presented and discussed. The potential benefits to faculty and students of using PowerPoint animations in…

  1. 40 CFR 63.745 - Standards: Primer and topcoat application operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system requirements. Each control system shall reduce the operation's organic HAP and VOC emissions to... control system that meets or exceeds the efficiency data points in Tables 1 and 2 of this section and is... pollution control system that meets or exceeds the efficiency data points in Tables 3 and 4 of this section...

  2. Earth-Moon Libration Point Orbit Stationkeeping: Theory, Modeling and Operations

    NASA Technical Reports Server (NTRS)

    Folta, David C.; Pavlak, Thomas A.; Haapala, Amanda F.; Howell, Kathleen C.; Woodard, Mark A.

    2013-01-01

    Collinear Earth-Moon libration points have emerged as locations with immediate applications. These libration point orbits are inherently unstable and must be maintained regularly which constrains operations and maneuver locations. Stationkeeping is challenging due to relatively short time scales for divergence effects of large orbital eccentricity of the secondary body, and third-body perturbations. Using the Acceleration Reconnection and Turbulence and Electrodynamics of the Moon's Interaction with the Sun (ARTEMIS) mission orbit as a platform, the fundamental behavior of the trajectories is explored using Poincare maps in the circular restricted three-body problem. Operational stationkeeping results obtained using the Optimal Continuation Strategy are presented and compared to orbit stability information generated from mode analysis based in dynamical systems theory.

  3. Piston Bowl Optimization for RCCI Combustion in a Light-Duty Multi-Cylinder Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanson, Reed M; Curran, Scott; Wagner, Robert M

    2012-01-01

    Reactivity Controlled Compression Ignition (RCCI) is an engine combustion strategy that that produces low NO{sub x} and PM emissions with high thermal efficiency. Previous RCCI research has been investigated in single-cylinder heavy-duty engines. The current study investigates RCCI operation in a light-duty multi-cylinder engine at 3 operating points. These operating points were chosen to cover a range of conditions seen in the US EPA light-duty FTP test. The operating points were chosen by the Ad Hoc working group to simulate operation in the FTP test. The fueling strategy for the engine experiments consisted of in-cylinder fuel blending using port fuel-injectionmore » (PFI) of gasoline and early-cycle, direct-injection (DI) of diesel fuel. At these 3 points, the stock engine configuration is compared to operation with both the original equipment manufacturer (OEM) and custom machined pistons designed for RCCI operation. The pistons were designed with assistance from the KIVA 3V computational fluid dynamics (CFD) code. By using a genetic algorithm optimization, in conjunction with KIVA, the piston bowl profile was optimized for dedicated RCCI operation to reduce unburned fuel emissions and piston bowl surface area. By reducing these parameters, the thermal efficiency of the engine was improved while maintaining low NOx and PM emissions. Results show that with the new piston bowl profile and an optimized injection schedule, RCCI brake thermal efficiency was increased from 37%, with the stock EURO IV configuration, to 40% at the 2,600 rev/min, 6.9 bar BMEP condition, and NOx and PM emissions targets were met without the need for exhaust after-treatment.« less

  4. Improvements in floating point addition/subtraction operations

    DOEpatents

    Farmwald, P.M.

    1984-02-24

    Apparatus is described for decreasing the latency time associated with floating point addition and subtraction in a computer, using a novel bifurcated, pre-normalization/post-normalization approach that distinguishes between differences of floating point exponents.

  5. Passive serialization in a multitasking environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennessey, J.P.; Osisek, D.L.; Seigh, J.W. II

    1989-02-28

    In a multiprocessing system having a control program in which data objects are shared among processes, this patent describes a method for serializing references to a data object by the processes so as to prevent invalid references to the data object by any process when an operation requiring exclusive access is performed by another process, comprising the steps of: permitting the processes to reference data objects on a shared access basis without obtaining a shared lock; monitoring a point of execution of the control program which is common to all processes in the system, which occurs regularly in the process'more » execution and across which no references to any data object can be maintained by any process, except references using locks; establishing a system reference point which occurs after each process in the system has passed the point of execution at least once since the last such system reference point; requesting an operation requiring exclusive access on a selected data object; preventing subsequent references by other processes to the selected data object; waiting until two of the system references points have occurred; and then performing the requested operation.« less

  6. Translation and validation of the new version of the Knee Society Score - The 2011 KS Score - into Brazilian Portuguese.

    PubMed

    Silva, Adriana Lucia Pastore E; Croci, Alberto Tesconi; Gobbi, Riccardo Gomes; Hinckel, Betina Bremer; Pecora, José Ricardo; Demange, Marco Kawamura

    2017-01-01

    Translation, cultural adaptation, and validation of the new version of the Knee Society Score - The 2011 KS Score - into Brazilian Portuguese and verification of its measurement properties, reproducibility, and validity. In 2012, the new version of the Knee Society Score was developed and validated. This scale comprises four separate subscales: (a) objective knee score (seven items: 100 points); (b) patient satisfaction score (five items: 40 points); (c) patient expectations score (three items: 15 points); and (d) functional activity score (19 items: 100 points). A total of 90 patients aged 55-85 years were evaluated in a clinical cross-sectional study. The pre-operative translated version was applied to patients with TKA referral, and the post-operative translated version was applied to patients who underwent TKA. Each patient answered the same questionnaire twice and was evaluated by two experts in orthopedic knee surgery. Evaluations were performed pre-operatively and three, six, or 12 months post-operatively. The reliability of the questionnaire was evaluated using the intraclass correlation coefficient (ICC) between the two applications. Internal consistency was evaluated using Cronbach's alpha. The ICC found no difference between the means of the pre-operative, three-month, and six-month post-operative evaluations between sub-scale items. The Brazilian Portuguese version of The 2011 KS Score is a valid and reliable instrument for objective and subjective evaluation of the functionality of Brazilian patients who undergo TKA and revision TKA.

  7. Annular Suspension and Pointing System (ASPS) magnetic rotary joint

    NASA Technical Reports Server (NTRS)

    Smith, W. E.; Quach, W.; Thomas, W.

    1993-01-01

    The Annular Suspension and Pointing System (ASPS) is a prototype of flight hardware for a high-accuracy space payload pointing mount. The long term project objective is to perform modifications and implement improvements to the existing ASPS in hopes of recommission. Also, new applications will be investigated for this technology. This report will focus on the first aspect of this overall goal, to establish operation of a single bearing station. Presented is an overview of the system history and bearing operation followed by the processes, results, and status of the single bearing study.

  8. Flight software operation of the Hubble Space Telescope fine guidance sensor

    NASA Technical Reports Server (NTRS)

    Rodden, J. J.; Dougherty, H. J.; Cormier, D. J.

    1988-01-01

    The Hubble Space Telescope (HST) is to carry five major scientific instruments to collect imagery, spectrographic, and photometric astronomical data. The Pointing Control System is designed to achieve pointing accuracies and line of sight jitter levels an order of magnitude less than can be achieved with ground mounted telescopes. This paper describes the operation of the pointing control system flight software in targeting a celestial object in a science instrument aperture and in performing the coordinate transformations necessary for commanding the fine guidance sensor and determining the attitude-error corrections.

  9. Point form relativistic quantum mechanics and relativistic SU(6)

    NASA Technical Reports Server (NTRS)

    Klink, W. H.

    1993-01-01

    The point form is used as a framework for formulating a relativistic quantum mechanics, with the mass operator carrying the interactions of underlying constituents. A symplectic Lie algebra of mass operators is introduced from which a relativistic harmonic oscillator mass operator is formed. Mass splittings within the degenerate harmonic oscillator levels arise from relativistically invariant spin-spin, spin-orbit, and tensor mass operators. Internal flavor (and color) symmetries are introduced which make it possible to formulate a relativistic SU(6) model of baryons (and mesons). Careful attention is paid to the permutation symmetry properties of the hadronic wave functions, which are written as polynomials in Bargmann spaces.

  10. Modular acute system for general surgery: hand over the operation, not the patient.

    PubMed

    Poole, Garth H; Glyn, Tamara; Srinivasa, Sanket; Hill, Andrew G

    2012-03-01

    Various models have been proposed to effectively provide acute surgical care in Australasia. Recently, General Surgeons Australia (GSA) has published a 12-point plan with guiding principles on this matter. This study describes a model of providing acute general surgical care in a high-volume institution, evaluates clinical outcomes and critically appraises the system against the GSA 12-point plan. The acute care system is qualitatively described with quantitative measures of workload. The outcomes of acute laparoscopic cholecystectomy were used as a proxy of system performance. The system was critically appraised against the GSA 12-point plan. Teams are on call once per week with each surgeon on call once per fortnight. The three key elements of acute management - collecting patients, post-acute ward round and operating - are treated as modules. The patient remains under the care of the admitting consultant but is often operated on by another team. From June 2009 to 2010, there were 7429 acute general surgical admissions (mean: 20.4 patients per day) with 2999 acute operations (mean: 8.4 operations per day). The other activities of the department were not compromised. In that time, 388 acute laparoscopic cholecystectomies were performed with a conversion rate of 1.3% and no major bile duct injury. The system is compatible with the GSA 12-point plan. This study describes an efficient and safe system for providing acute general surgical care in a high-volume setting with satisfactory clinical outcomes. It is compatible with the GSA 12-point plan. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  11. NARMER-1: a photon point-kernel code with build-up factors

    NASA Astrophysics Data System (ADS)

    Visonneau, Thierry; Pangault, Laurence; Malouch, Fadhel; Malvagi, Fausto; Dolci, Florence

    2017-09-01

    This paper presents an overview of NARMER-1, the new generation of photon point-kernel code developed by the Reactor Studies and Applied Mathematics Unit (SERMA) at CEA Saclay Center. After a short introduction giving some history points and the current context of development of the code, the paper exposes the principles implemented in the calculation, the physical quantities computed and surveys the generic features: programming language, computer platforms, geometry package, sources description, etc. Moreover, specific and recent features are also detailed: exclusion sphere, tetrahedral meshes, parallel operations. Then some points about verification and validation are presented. Finally we present some tools that can help the user for operations like visualization and pre-treatment.

  12. Performance prediction evaluation of ceramic materials in point-focusing solar receivers

    NASA Technical Reports Server (NTRS)

    Ewing, J.; Zwissler, J.

    1979-01-01

    A performance prediction was adapted to evaluate the use of ceramic materials in solar receivers for point focusing distributed applications. System requirements were determined including the receiver operating environment and system operating parameters for various engine types. Preliminary receiver designs were evolved from these system requirements. Specific receiver designs were then evaluated to determine material functional requirements.

  13. SNAP 10A ESTIMATED ELECTRICAL CHARACTERISTICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, J.C.

    1961-06-01

    The electrical power characteristics of a SNAP 10A converter are estimated for given fractions of power degradation. Graphs are included showing the power characteristics for instantaneous transients from stabilized operation at the maximum efficiency point, and after system temperature stabilization at the operating point. Open-circuit emf's of the converter are estimated for instantaneous and temperature-stabilized cases. (D.L.C.)

  14. 77 FR 36015 - Atomic Safety and Licensing Board; Entergy Nuclear Operations, Inc. (Indian Point Nuclear...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247-LR and 50-286-LR; ASLBP No. 07-858-03-LR-BD01] Atomic Safety and Licensing Board; Entergy Nuclear Operations, Inc. (Indian Point Nuclear Generating Units 2 and 3); Notice of Hearing (Application for License Renewal) June 8, 2012. Before Administrative Judges: Lawrence G. McDade, Chairman, Dr....

  15. Optimal Trajectories for the Helicopter in One-Engine-Inoperative Terminal-Area Operations

    NASA Technical Reports Server (NTRS)

    Zhao, Yiyuan; Chen, Robert T. N.

    1996-01-01

    This paper presents a summary of a series of recent analytical studies conducted to investigate One-Engine-Inoperative (OEI) optimal control strategies and the associated optimal trajectories for a twin engine helicopter in Category-A terminal-area operations. These studies also examine the associated heliport size requirements and the maximum gross weight capability of the helicopter. Using an eight states, two controls, augmented point-mass model representative of the study helicopter, Continued TakeOff (CTO), Rejected TakeOff (RTO), Balked Landing (BL), and Continued Landing (CL) are investigated for both Vertical-TakeOff-and-Landing (VTOL) and Short-TakeOff-and-Landing (STOL) terminal-area operations. The formulation of the nonlinear optimal control problems with considerations for realistic constraints, solution methods for the two-point boundary-value problem, a new real-time generation method for the optimal OEI trajectories, and the main results of this series of trajectory optimization studies are presented. In particular, a new balanced- weight concept for determining the takeoff decision point for VTOL Category-A operations is proposed, extending the balanced-field length concept used for STOL operations.

  16. Towards an Entropy Stable Spectral Element Framework for Computational Fluid Dynamics

    NASA Technical Reports Server (NTRS)

    Carpenter, Mark H.; Parsani, Matteo; Fisher, Travis C.; Nielsen, Eric J.

    2016-01-01

    Entropy stable (SS) discontinuous spectral collocation formulations of any order are developed for the compressible Navier-Stokes equations on hexahedral elements. Recent progress on two complementary efforts is presented. The first effort is a generalization of previous SS spectral collocation work to extend the applicable set of points from tensor product, Legendre-Gauss-Lobatto (LGL) to tensor product Legendre-Gauss (LG) points. The LG and LGL point formulations are compared on a series of test problems. Although being more costly to implement, it is shown that the LG operators are significantly more accurate on comparable grids. Both the LGL and LG operators are of comparable efficiency and robustness, as is demonstrated using test problems for which conventional FEM techniques suffer instability. The second effort generalizes previous SS work to include the possibility of p-refinement at non-conforming interfaces. A generalization of existing entropy stability machinery is developed to accommodate the nuances of fully multi-dimensional summation-by-parts (SBP) operators. The entropy stability of the compressible Euler equations on non-conforming interfaces is demonstrated using the newly developed LG operators and multi-dimensional interface interpolation operators.

  17. Neurological surgery: the influence of physical and mental demands on humans performing complex operations.

    PubMed

    Bourne, Sarah K; Walcott, Brian P; Sheth, Sameer A; Coumans, Jean-Valery C E

    2013-03-01

    Performing neurological surgery is an inherently demanding task on the human body, both physically and mentally. Neurosurgeons routinely perform "high stakes" operations in the setting of mental and physical fatigue. These conditions may be not only the result of demanding operations, but also influential to their outcome. Similar to other performance-based endurance activities, training is paramount to successful outcomes. The inflection point, where training reaches the point of diminishing returns, is intensely debated. For the neurosurgeon, this point must be exploited to the maximum, as patients require both the best-trained and best-performing surgeon. In this review, we explore the delicate balance of training and performance, as well as some routinely used adjuncts to improve human performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Nonlocal games and optimal steering at the boundary of the quantum set

    NASA Astrophysics Data System (ADS)

    Zhen, Yi-Zheng; Goh, Koon Tong; Zheng, Yu-Lin; Cao, Wen-Fei; Wu, Xingyao; Chen, Kai; Scarani, Valerio

    2016-08-01

    The boundary between classical and quantum correlations is well characterized by linear constraints called Bell inequalities. It is much harder to characterize the boundary of the quantum set itself in the space of no-signaling correlations. For the points on the quantum boundary that violate maximally some Bell inequalities, J. Oppenheim and S. Wehner [Science 330, 1072 (2010), 10.1126/science.1192065] pointed out a complex property: Alice's optimal measurements steer Bob's local state to the eigenstate of an effective operator corresponding to its maximal eigenvalue. This effective operator is the linear combination of Bob's local operators induced by the coefficients of the Bell inequality, and it can be interpreted as defining a fine-grained uncertainty relation. It is natural to ask whether the same property holds for other points on the quantum boundary, using the Bell expression that defines the tangent hyperplane at each point. We prove that this is indeed the case for a large set of points, including some that were believed to provide counterexamples. The price to pay is to acknowledge that the Oppenheim-Wehner criterion does not respect equivalence under the no-signaling constraint: for each point, one has to look for specific forms of writing the Bell expressions.

  19. A class of renormalised meshless Laplacians for boundary value problems

    NASA Astrophysics Data System (ADS)

    Basic, Josip; Degiuli, Nastia; Ban, Dario

    2018-02-01

    A meshless approach to approximating spatial derivatives on scattered point arrangements is presented in this paper. Three various derivations of approximate discrete Laplace operator formulations are produced using the Taylor series expansion and renormalised least-squares correction of the first spatial derivatives. Numerical analyses are performed for the introduced Laplacian formulations, and their convergence rate and computational efficiency are examined. The tests are conducted on regular and highly irregular scattered point arrangements. The results are compared to those obtained by the smoothed particle hydrodynamics method and the finite differences method on a regular grid. Finally, the strong form of various Poisson and diffusion equations with Dirichlet or Robin boundary conditions are solved in two and three dimensions by making use of the introduced operators in order to examine their stability and accuracy for boundary value problems. The introduced Laplacian operators perform well for highly irregular point distribution and offer adequate accuracy for mesh and mesh-free numerical methods that require frequent movement of the grid or point cloud.

  20. The next step in health data exchanges: trust and privacy in exchange networks.

    PubMed

    Gravely, Steve D; Whaley, Erin S

    2009-01-01

    The rapid development of health information exchanges (HIE), regional health information organizations (RHIO), the Nationwide Health Information Network (NHIN) and other data exchange platforms for health records creates complex and multifaceted challenges for protecting the privacy and security of health information. Often these issues are addressed in a contractual agreement between two parties seeking to exchange data. Until recently, this point-to-point approach has been acceptable because there were few operational HIEs or RHIOs that were ready, willing and able to actually exchange data. With the proliferation of HIEs and RHIOs that are either operational or on the cusp of being operational, the utility of point-to-point is diminishing. It is no longer efficient for a RHIO to negotiate a separate data exchange agreement with every one of its exchange partners. The evolving model for data exchange agreements is a multi-party trust agreement. This article will examine the crucial components of a multi-party trust agreement.

  1. A Data Filter for Identifying Steady-State Operating Points in Engine Flight Data for Condition Monitoring Applications

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Litt, Jonathan S.

    2010-01-01

    This paper presents an algorithm that automatically identifies and extracts steady-state engine operating points from engine flight data. It calculates the mean and standard deviation of select parameters contained in the incoming flight data stream. If the standard deviation of the data falls below defined constraints, the engine is assumed to be at a steady-state operating point, and the mean measurement data at that point are archived for subsequent condition monitoring purposes. The fundamental design of the steady-state data filter is completely generic and applicable for any dynamic system. Additional domain-specific logic constraints are applied to reduce data outliers and variance within the collected steady-state data. The filter is designed for on-line real-time processing of streaming data as opposed to post-processing of the data in batch mode. Results of applying the steady-state data filter to recorded helicopter engine flight data are shown, demonstrating its utility for engine condition monitoring applications.

  2. Log amplifier with pole-zero compensation

    DOEpatents

    Brookshier, W.

    1985-02-08

    A logarithmic amplifier circuit provides pole-zero compensation for improved stability and response time over 6-8 decades of input signal frequency. The amplifer circuit includes a first operational amplifier with a first feedback loop which includes a second, inverting operational amplifier in a second feedstock loop. The compensated output signal is provided by the second operational amplifier with the log elements, i.e., resistors, and the compensating capacitors in each of the feedback loops having equal values so that each break point is offset by a compensating break point or zero.

  3. Log amplifier with pole-zero compensation

    DOEpatents

    Brookshier, William

    1987-01-01

    A logarithmic amplifier circuit provides pole-zero compensation for improved stability and response time over 6-8 decades of input signal frequency. The amplifier circuit includes a first operational amplifier with a first feedback loop which includes a second, inverting operational amplifier in a second feedback loop. The compensated output signal is provided by the second operational amplifier with the log elements, i.e., resistors, and the compensating capacitors in each of the feedback loops having equal values so that each break point or pole is offset by a compensating break point or zero.

  4. Solving the multiple-set split equality common fixed-point problem of firmly quasi-nonexpansive operators.

    PubMed

    Zhao, Jing; Zong, Haili

    2018-01-01

    In this paper, we propose parallel and cyclic iterative algorithms for solving the multiple-set split equality common fixed-point problem of firmly quasi-nonexpansive operators. We also combine the process of cyclic and parallel iterative methods and propose two mixed iterative algorithms. Our several algorithms do not need any prior information about the operator norms. Under mild assumptions, we prove weak convergence of the proposed iterative sequences in Hilbert spaces. As applications, we obtain several iterative algorithms to solve the multiple-set split equality problem.

  5. Universal Common Communication Substrate (UCCS) Specification; Universal Common Communication Substrate (UCCS) Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Universal Common Communication Substrate (UCCS) is a low-level communication substrate that exposes high-performance communication primitives, while providing network interoperability. It is intended to support multiple upper layer protocol (ULPs) or programming models including SHMEM,UPC,Titanium,Co-Array Fortran,Global Arrays,MPI,GASNet, and File I/O. it provides various communication operations including one-sided and two-sided point-to-point, collectives, and remote atomic operations. In addition to operations for ULPs, it provides an out-of-band communication channel required typically required to wire-up communication libraries.

  6. Estimation of the laser cutting operating cost by support vector regression methodology

    NASA Astrophysics Data System (ADS)

    Jović, Srđan; Radović, Aleksandar; Šarkoćević, Živče; Petković, Dalibor; Alizamir, Meysam

    2016-09-01

    Laser cutting is a popular manufacturing process utilized to cut various types of materials economically. The operating cost is affected by laser power, cutting speed, assist gas pressure, nozzle diameter and focus point position as well as the workpiece material. In this article, the process factors investigated were: laser power, cutting speed, air pressure and focal point position. The aim of this work is to relate the operating cost to the process parameters mentioned above. CO2 laser cutting of stainless steel of medical grade AISI316L has been investigated. The main goal was to analyze the operating cost through the laser power, cutting speed, air pressure, focal point position and material thickness. Since the laser operating cost is a complex, non-linear task, soft computing optimization algorithms can be used. Intelligent soft computing scheme support vector regression (SVR) was implemented. The performance of the proposed estimator was confirmed with the simulation results. The SVR results are then compared with artificial neural network and genetic programing. According to the results, a greater improvement in estimation accuracy can be achieved through the SVR compared to other soft computing methodologies. The new optimization methods benefit from the soft computing capabilities of global optimization and multiobjective optimization rather than choosing a starting point by trial and error and combining multiple criteria into a single criterion.

  7. Operant Conditioning: A Tool for Special Physical Educators in the 1980s.

    ERIC Educational Resources Information Center

    Dunn, John M.; French, Ron

    1982-01-01

    The usefulness of operant conditioning for the special physical educator in managing behavior problems is pointed out, and steps to follow in applying operant conditioning techniques are outlined. (SB)

  8. 14 CFR 294.30 - Scope of service and equipment authorized.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... between any point or points in Canada and any point or points in the United States using small aircraft. (b) Nothing in this part shall be construed as authorizing the operation of large aircraft in charter... with the limitations and conditions of this part using aircraft designed to have: (1) A maximum...

  9. 14 CFR 294.30 - Scope of service and equipment authorized.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... between any point or points in Canada and any point or points in the United States using small aircraft. (b) Nothing in this part shall be construed as authorizing the operation of large aircraft in charter... with the limitations and conditions of this part using aircraft designed to have: (1) A maximum...

  10. 14 CFR 294.30 - Scope of service and equipment authorized.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... between any point or points in Canada and any point or points in the United States using small aircraft. (b) Nothing in this part shall be construed as authorizing the operation of large aircraft in charter... with the limitations and conditions of this part using aircraft designed to have: (1) A maximum...

  11. 3D facial landmarks: Inter-operator variability of manual annotation

    PubMed Central

    2014-01-01

    Background Manual annotation of landmarks is a known source of variance, which exist in all fields of medical imaging, influencing the accuracy and interpretation of the results. However, the variability of human facial landmarks is only sparsely addressed in the current literature as opposed to e.g. the research fields of orthodontics and cephalometrics. We present a full facial 3D annotation procedure and a sparse set of manually annotated landmarks, in effort to reduce operator time and minimize the variance. Method Facial scans from 36 voluntary unrelated blood donors from the Danish Blood Donor Study was randomly chosen. Six operators twice manually annotated 73 anatomical and pseudo-landmarks, using a three-step scheme producing a dense point correspondence map. We analyzed both the intra- and inter-operator variability, using mixed-model ANOVA. We then compared four sparse sets of landmarks in order to construct a dense correspondence map of the 3D scans with a minimum point variance. Results The anatomical landmarks of the eye were associated with the lowest variance, particularly the center of the pupils. Whereas points of the jaw and eyebrows have the highest variation. We see marginal variability in regards to intra-operator and portraits. Using a sparse set of landmarks (n=14), that capture the whole face, the dense point mean variance was reduced from 1.92 to 0.54 mm. Conclusion The inter-operator variability was primarily associated with particular landmarks, where more leniently landmarks had the highest variability. The variables embedded in the portray and the reliability of a trained operator did only have marginal influence on the variability. Further, using 14 of the annotated landmarks we were able to reduced the variability and create a dense correspondences mesh to capture all facial features. PMID:25306436

  12. Verification of floating-point software

    NASA Technical Reports Server (NTRS)

    Hoover, Doug N.

    1990-01-01

    Floating point computation presents a number of problems for formal verification. Should one treat the actual details of floating point operations, or accept them as imprecisely defined, or should one ignore round-off error altogether and behave as if floating point operations are perfectly accurate. There is the further problem that a numerical algorithm usually only approximately computes some mathematical function, and we often do not know just how good the approximation is, even in the absence of round-off error. ORA has developed a theory of asymptotic correctness which allows one to verify floating point software with a minimum entanglement in these problems. This theory and its implementation in the Ariel C verification system are described. The theory is illustrated using a simple program which finds a zero of a given function by bisection. This paper is presented in viewgraph form.

  13. Three-Point Functions in c≤1 Liouville Theory and Conformal Loop Ensembles.

    PubMed

    Ikhlef, Yacine; Jacobsen, Jesper Lykke; Saleur, Hubert

    2016-04-01

    The possibility of extending the Liouville conformal field theory from values of the central charge c≥25 to c≤1 has been debated for many years in condensed matter physics as well as in string theory. It was only recently proven that such an extension-involving a real spectrum of critical exponents as well as an analytic continuation of the Dorn-Otto-Zamolodchikov-Zamolodchikov formula for three-point couplings-does give rise to a consistent theory. We show in this Letter that this theory can be interpreted in terms of microscopic loop models. We introduce in particular a family of geometrical operators, and, using an efficient algorithm to compute three-point functions from the lattice, we show that their operator algebra corresponds exactly to that of vertex operators V_{α[over ^]} in c≤1 Liouville theory. We interpret geometrically the limit α[over ^]→0 of V_{α[over ^]} and explain why it is not the identity operator (despite having conformal weight Δ=0).

  14. Alarms Philosophy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Karen S; Kasemir, Kay

    2009-01-01

    An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits.more » In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.« less

  15. Fermion-scalar conformal blocks

    DOE PAGES

    Iliesiu, Luca; Kos, Filip; Poland, David; ...

    2016-04-13

    In this study, we compute the conformal blocks associated with scalar-scalar-fermionfermion 4-point functions in 3D CFTs. Together with the known scalar conformal blocks, our result completes the task of determining the so-called ‘seed blocks’ in three dimensions. In addition, conformal blocks associated with 4-point functions of operators with arbitrary spins can now be determined from these seed blocks by using known differential operators.

  16. On the existence of point spectrum for branching strips quantum graph

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popov, I. Yu., E-mail: popov1955@gmail.com; Skorynina, A. N.; Blinova, I. V., E-mail: irin-a@yandex.ru

    2014-03-15

    The quantum graph having the form of branching strips with hexagonal (honeycomb) structure is considered. The Hamiltonian is determined as free 1D Schrödinger operator on each edge and some “boundary” conditions at each vertex. We obtain the conditions ensuring the point spectrum's existence for the Schrödinger operator of the system and relations that give us the eigenvalues.

  17. Laparoscopic repair of inguinal hernia in adults

    PubMed Central

    Yang, Xue-Fei

    2016-01-01

    Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. The procedures include intraperitoneal onlay mesh (IPOM) repair, transabdominal preperitoneal (TAPP) repair and total extraperitoneal (TEP) repair. These procedures have totally different anatomic point of view, process and technical key points from open operations. The technical details of these operations are discussed in this article, also the strategies of treatment for some special conditions. PMID:27867954

  18. 75 FR 14639 - Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 1, 2, and 3...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-003, 50-247, and 50-286; NRC-2010-0137] Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 1, 2, and 3; Environmental Assessment and Finding of No Significant Impact The U.S. Nuclear Regulatory Commission (NRC) is considering issuance of an exemption, pursuant to Title 10 of...

  19. 75 FR 77920 - Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 2 and 3; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-14

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247 and 50-286; NRC-2008-0672] Entergy Nuclear Operations, Inc.; Indian Point Nuclear Generating Unit Nos. 2 and 3; Notice of Availability of the Final Supplement 38 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Notice is hereby given that the U.S. Nuclear...

  20. 16 CFR § 1211.7 - Inherent entrapment protection requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... operator reverses the door a minimum of 2 inches (50.8 mm). (b)(1) A solid object is to be placed on the... the door, a solid object is not required to be located in line with the driving point of the operator. The solid object is to be located at points at the center, and within 1 foot of each end of the door...

  1. Sensor-Based Optimized Control of the Full Load Instability in Large Hydraulic Turbines

    PubMed Central

    Presas, Alexandre; Valero, Carme; Egusquiza, Eduard

    2018-01-01

    Hydropower plants are of paramount importance for the integration of intermittent renewable energy sources in the power grid. In order to match the energy generated and consumed, Large hydraulic turbines have to work under off-design conditions, which may lead to dangerous unstable operating points involving the hydraulic, mechanical and electrical system. Under these conditions, the stability of the grid and the safety of the power plant itself can be compromised. For many Francis Turbines one of these critical points, that usually limits the maximum output power, is the full load instability. Therefore, these machines usually work far away from this unstable point, reducing the effective operating range of the unit. In order to extend the operating range of the machine, working closer to this point with a reasonable safety margin, it is of paramount importance to monitor and to control relevant parameters of the unit, which have to be obtained with an accurate sensor acquisition strategy. Within the framework of a large EU project, field tests in a large Francis Turbine located in Canada (rated power of 444 MW) have been performed. Many different sensors were used to monitor several working parameters of the unit for all its operating range. Particularly for these tests, more than 80 signals, including ten type of different sensors and several operating signals that define the operating point of the unit, were simultaneously acquired. The present study, focuses on the optimization of the acquisition strategy, which includes type, number, location, acquisition frequency of the sensors and corresponding signal analysis to detect the full load instability and to prevent the unit from reaching this point. A systematic approach to determine this strategy has been followed. It has been found that some indicators obtained with different types of sensors are linearly correlated with the oscillating power. The optimized strategy has been determined based on the correlation characteristics (linearity, sensitivity and reactivity), the simplicity of the installation and the acquisition frequency necessary. Finally, an economic and easy implementable protection system based on the resulting optimized acquisition strategy is proposed. This system, which can be used in a generic Francis turbine with a similar full load instability, permits one to extend the operating range of the unit by working close to the instability with a reasonable safety margin. PMID:29601512

  2. Sensor-Based Optimized Control of the Full Load Instability in Large Hydraulic Turbines.

    PubMed

    Presas, Alexandre; Valentin, David; Egusquiza, Mònica; Valero, Carme; Egusquiza, Eduard

    2018-03-30

    Hydropower plants are of paramount importance for the integration of intermittent renewable energy sources in the power grid. In order to match the energy generated and consumed, Large hydraulic turbines have to work under off-design conditions, which may lead to dangerous unstable operating points involving the hydraulic, mechanical and electrical system. Under these conditions, the stability of the grid and the safety of the power plant itself can be compromised. For many Francis Turbines one of these critical points, that usually limits the maximum output power, is the full load instability. Therefore, these machines usually work far away from this unstable point, reducing the effective operating range of the unit. In order to extend the operating range of the machine, working closer to this point with a reasonable safety margin, it is of paramount importance to monitor and to control relevant parameters of the unit, which have to be obtained with an accurate sensor acquisition strategy. Within the framework of a large EU project, field tests in a large Francis Turbine located in Canada (rated power of 444 MW) have been performed. Many different sensors were used to monitor several working parameters of the unit for all its operating range. Particularly for these tests, more than 80 signals, including ten type of different sensors and several operating signals that define the operating point of the unit, were simultaneously acquired. The present study, focuses on the optimization of the acquisition strategy, which includes type, number, location, acquisition frequency of the sensors and corresponding signal analysis to detect the full load instability and to prevent the unit from reaching this point. A systematic approach to determine this strategy has been followed. It has been found that some indicators obtained with different types of sensors are linearly correlated with the oscillating power. The optimized strategy has been determined based on the correlation characteristics (linearity, sensitivity and reactivity), the simplicity of the installation and the acquisition frequency necessary. Finally, an economic and easy implementable protection system based on the resulting optimized acquisition strategy is proposed. This system, which can be used in a generic Francis turbine with a similar full load instability, permits one to extend the operating range of the unit by working close to the instability with a reasonable safety margin.

  3. 77 FR 41454 - Entergy Nuclear Indian Point Unit 2, LLC, Entergy Nuclear Indian Point Unit 3, LLC, Entergy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-247 and 50-286; NRC-2012-0168] Entergy Nuclear Indian Point Unit 2, LLC, Entergy Nuclear Indian Point Unit 3, LLC, Entergy Nuclear Operations, Inc., Indian Point Nuclear Generating Units 2 and 3; Environmental Assessment and Finding of No Significant Impact The U.S. Nuclear Regulatory Commission (NRC...

  4. 14 CFR 135.100 - Flight crewmember duties.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the air carrier or pointing out sights of interest, and filling out company payroll and related...) AIR CARRIERS AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS OPERATING... operation of the aircraft. Duties such as company required calls made for such nonsafety related purposes as...

  5. Spaceborne receivers: Basic principles

    NASA Technical Reports Server (NTRS)

    Stacey, J. M.

    1984-01-01

    The underlying principles of operation of microwave receivers for space observations of planetary surfaces were examined. The design philosophy of the receiver as it is applied to operate functionally as an efficient receiving system, the principle of operation of the key components of the receiver, and the important differences among receiver types are explained. The operating performance and the sensitivity expectations for both the modulated and total power receiver configurations are outlined. The expressions are derived from first principles and are developed through the important intermediate stages to form practicle and easily applied equations. The transfer of thermodynamic energy from point to point within the receiver is illustrated. The language of microwave receivers is applied statistics.

  6. 47 CFR 101.107 - Frequency tolerance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...

  7. 47 CFR 101.107 - Frequency tolerance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...

  8. 47 CFR 101.107 - Frequency tolerance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...

  9. 12 CFR 217.161 - Qualification requirements for incorporation of operational risk mitigants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operational risk exposure to reflect qualifying operational risk mitigants if: (1) The Board-regulated...) Qualifying operational risk mitigants. Qualifying operational risk mitigants are: (1) Insurance that: (i) Is... institution assigns the company is assigned a PD equal to or less than 10 basis points; (ii) Has an initial...

  10. 12 CFR 324.161 - Qualification requirements for incorporation of operational risk mitigants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operational risk exposure to reflect qualifying operational risk mitigants if: (1) The FDIC-supervised...) Qualifying operational risk mitigants. Qualifying operational risk mitigants are: (1) Insurance that: (i) Is... institution assigns the company is assigned a PD equal to or less than 10 basis points; (ii) Has an initial...

  11. Association between patient-centered medical home rating and operating cost at federally funded health centers.

    PubMed

    Nocon, Robert S; Sharma, Ravi; Birnberg, Jonathan M; Ngo-Metzger, Quyen; Lee, Sang Mee; Chin, Marshall H

    2012-07-04

    Little is known about the cost associated with a health center's rating as a patient-centered medical home (PCMH). To determine whether PCMH rating is associated with operating cost among health centers funded by the US Health Resources and Services Administration. Cross-sectional study of PCMH rating and operating cost in 2009. PCMH rating was assessed through surveys of health center administrators conducted by Harris Interactive of all 1009 Health Resources and Services Administration–funded community health centers. The survey provided scores from 0 (worst) to 100 (best) for total PCMH score and 6 subscales: access/communication, care management, external coordination, patient tracking, test/referral tracking, and quality improvement. Costs were obtained from the Uniform Data System reports submitted to the Health Resources and Services Administration. We used generalized linear models to determine the relationship between PCMH rating and operating cost. Operating cost per physician full-time equivalent, operating cost per patient per month, and medical cost per visit. Six hundred sixty-nine health centers (66%) were included in the study sample, with 340 excluded because of nonresponse or incomplete data. Mean total PCMH score was 60 (SD, 12; range, 21-90). For the average health center, a 10-point higher total PCMH score was associated with a $2.26 (4.6%) higher operating cost per patient per month (95% CI, $0.86-$4.12). Among PCMH subscales, a 10-point higher score for patient tracking was associated with higher operating cost per physician full-time equivalent ($27,300; 95% CI, $3047-$57,804) and higher operating cost per patient per month ($1.06; 95% CI, $0.29-$1.98). A 10-point higher score for quality improvement was also associated with higher operating cost per physician full-time equivalent ($32,731; 95% CI, $1571-$73,670) and higher operating cost per patient per month ($1.86; 95% CI, $0.54-$3.61). A 10-point higher PCMH subscale score for access/communication was associated with lower operating cost per physician full-time equivalent ($39,809; 95% CI, $1893-$63,169). According to a survey of health center administrators, higher scores on a scale that assessed 6 aspects of the PCMH were associated with higher health center operating costs. Two subscales of the medical home were associated with higher cost and 1 with lower cost.

  12. Antenna Controller Replacement Software

    NASA Technical Reports Server (NTRS)

    Chao, Roger Y.; Morgan, Scott C.; Strain, Martha M.; Rockwell, Stephen T.; Shimizu, Kenneth J.; Tehrani, Barzia J.; Kwok, Jaclyn H.; Tuazon-Wong, Michelle; Valtier, Henry; Nalbandi, Reza; hide

    2010-01-01

    The Antenna Controller Replacement (ACR) software accurately points and monitors the Deep Space Network (DSN) 70-m and 34-m high-efficiency (HEF) ground-based antennas that are used to track primarily spacecraft and, periodically, celestial targets. To track a spacecraft, or other targets, the antenna must be accurately pointed at the spacecraft, which can be very far away with very weak signals. ACR s conical scanning capability collects the signal in a circular pattern around the target, calculates the location of the strongest signal, and adjusts the antenna pointing to point directly at the spacecraft. A real-time, closed-loop servo control algorithm performed every 0.02 second allows accurate positioning of the antenna in order to track these distant spacecraft. Additionally, this advanced servo control algorithm provides better antenna pointing performance in windy conditions. The ACR software provides high-level commands that provide a very easy user interface for the DSN operator. The operator only needs to enter two commands to start the antenna and subreflector, and Master Equatorial tracking. The most accurate antenna pointing is accomplished by aligning the antenna to the Master Equatorial, which because of its small size and sheltered location, has the most stable pointing. The antenna has hundreds of digital and analog monitor points. The ACR software provides compact displays to summarize the status of the antenna, subreflector, and the Master Equatorial. The ACR software has two major functions. First, it performs all of the steps required to accurately point the antenna (and subreflector and Master Equatorial) at the spacecraft (or celestial target). This involves controlling the antenna/ subreflector/Master-Equatorial hardware, initiating and monitoring the correct sequence of operations, calculating the position of the spacecraft relative to the antenna, executing the real-time servo control algorithm to maintain the correct position, and monitoring tracking performance.

  13. 75 FR 4426 - Florida Power and Light Company; Turkey Point Nuclear Generating Units 3 and 4; Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... Light Company; Turkey Point Nuclear Generating Units 3 and 4; Environmental Assessment and Finding of No... (the licensee), for operation of the Turkey Point Units 3 and 4, located in Miami, Florida. In...-ductility temperature) of the Linde 80 weld materials present in the beltline region of the Turkey Point...

  14. Passive thermo-optic feedback for robust athermal photonic systems

    DOEpatents

    Rakich, Peter T.; Watts, Michael R.; Nielson, Gregory N.

    2015-06-23

    Thermal control devices, photonic systems and methods of stabilizing a temperature of a photonic system are provided. A thermal control device thermally coupled to a substrate includes a waveguide for receiving light, an absorption element optically coupled to the waveguide for converting the received light to heat and an optical filter. The optical filter is optically coupled to the waveguide and thermally coupled to the absorption element. An operating point of the optical filter is tuned responsive to the heat from the absorption element. When the operating point is less than a predetermined temperature, the received light is passed to the absorption element via the optical filter. When the operating point is greater than or equal to the predetermined temperature, the received light is transmitted out of the thermal control device via the optical filter, without being passed to the absorption element.

  15. Optimizing operating parameters of a honeycomb zeolite rotor concentrator for processing TFT-LCD volatile organic compounds with competitive adsorption characteristics.

    PubMed

    Lin, Yu-Chih; Chang, Feng-Tang

    2009-05-30

    In this study, we attempted to enhance the removal efficiency of a honeycomb zeolite rotor concentrator (HZRC), operated at optimal parameters, for processing TFT-LCD volatile organic compounds (VOCs) with competitive adsorption characteristics. The results indicated that when the HZRC processed a VOCs stream of mixed compounds, compounds with a high boiling point take precedence in the adsorption process. In addition, existing compounds with a low boiling point adsorbed onto the HZRC were also displaced by the high-boiling-point compounds. In order to achieve optimal operating parameters for high VOCs removal efficiency, results suggested controlling the inlet velocity to <1.5m/s, reducing the concentration ratio to 8 times, increasing the desorption temperature to 200-225 degrees C, and setting the rotation speed to 6.5rpm.

  16. Ergonomic comparison of operating a built-in touch-pad pointing device and a trackball mouse on posture and muscle activity.

    PubMed

    Lee, Tzu-Hsien

    2005-12-01

    This study examined the effects of operating a built-in touch-pad pointing device and a trackball mouse on participants' completion times, hand positions during operation, postural angles, and muscle activities. 8 young men were asked to perform a cursor travel task on a notebook computer using both 60- and 80-cm high table conditions. Analysis showed that the trackball mouse significantly decreased completion times. Participants selected a hand position farther from the table edge and larger elbow angle for the trackball mouse than for the built-in touch-pad pointing device. Participants' neck, thoracic, and arm angles, or splenius capitis, trapezius, deltoid, and erector spinae muscle activities were not significantly affected by the devices, but table height significantly affected participants' completion times, hand positions, and postural angles.

  17. On Operating a Nanofiltration Membrane for Olive Mill Wastewater Purification at Sub- and Super-Boundary Conditions.

    PubMed

    Stoller, Marco; Ochando-Pulido, Javier Miguel; Field, Robert

    2017-07-14

    In the last decades, membrane processes have gained a significant share of the market for wastewater purification. Although the product (i.e., purified water) is not of high added value, these processes are feasible both technically and from an economic point of view, provided the flux is relatively high and that membrane fouling is strongly inhibited. By controlling membrane fouling, the membrane may work for years without service, thus dramatically reducing operating costs and the need for membrane substitution. There is tension between operating at high permeate fluxes, which enhances fouling but reduces capital costs, and operating at lower fluxes which increases capital costs. Operating batch membrane processes leads to increased difficulties, since the feed fed to the membrane changes as a function of the recovery value. This paper is concerned with the operation of such a process. Membrane process designers should therefore avoid membrane fouling by operating membranes away from the permeate flux point where severe fouling is triggered. The design and operation of membrane purification plants is a difficult task, and the precision to properly describe the evolution of the fouling phenomenon as a function of the operating conditions is a key to success. Many reported works have reported on the control of fouling by operating below the boundary flux. On the other hand, only a few works have successfully sought to exploit super-boundary operating conditions; most super-boundary operations are reported to have led to process failures. In this work, both sub- and super-boundary operating conditions for a batch nanofiltration membrane process used for olive mill wastewater treatment were investigated. A model to identify a priori the point of transition from a sub-boundary to a super-boundary operation during a batch operation was developed, and this will provide membrane designers with a helpful tool to carefully avoid process failures.

  18. The Unified Floating Point Vector Coprocessor for Reconfigurable Hardware

    NASA Astrophysics Data System (ADS)

    Kathiara, Jainik

    There has been an increased interest recently in using embedded cores on FPGAs. Many of the applications that make use of these cores have floating point operations. Due to the complexity and expense of floating point hardware, these algorithms are usually converted to fixed point operations or implemented using floating-point emulation in software. As the technology advances, more and more homogeneous computational resources and fixed function embedded blocks are added to FPGAs and hence implementation of floating point hardware becomes a feasible option. In this research we have implemented a high performance, autonomous floating point vector Coprocessor (FPVC) that works independently within an embedded processor system. We have presented a unified approach to vector and scalar computation, using a single register file for both scalar operands and vector elements. The Hybrid vector/SIMD computational model of FPVC results in greater overall performance for most applications along with improved peak performance compared to other approaches. By parameterizing vector length and the number of vector lanes, we can design an application specific FPVC and take optimal advantage of the FPGA fabric. For this research we have also initiated designing a software library for various computational kernels, each of which adapts FPVC's configuration and provide maximal performance. The kernels implemented are from the area of linear algebra and include matrix multiplication and QR and Cholesky decomposition. We have demonstrated the operation of FPVC on a Xilinx Virtex 5 using the embedded PowerPC.

  19. Complex systems analysis of series of blackouts: cascading failure, critical points, and self-organization.

    PubMed

    Dobson, Ian; Carreras, Benjamin A; Lynch, Vickie E; Newman, David E

    2007-06-01

    We give an overview of a complex systems approach to large blackouts of electric power transmission systems caused by cascading failure. Instead of looking at the details of particular blackouts, we study the statistics and dynamics of series of blackouts with approximate global models. Blackout data from several countries suggest that the frequency of large blackouts is governed by a power law. The power law makes the risk of large blackouts consequential and is consistent with the power system being a complex system designed and operated near a critical point. Power system overall loading or stress relative to operating limits is a key factor affecting the risk of cascading failure. Power system blackout models and abstract models of cascading failure show critical points with power law behavior as load is increased. To explain why the power system is operated near these critical points and inspired by concepts from self-organized criticality, we suggest that power system operating margins evolve slowly to near a critical point and confirm this idea using a power system model. The slow evolution of the power system is driven by a steady increase in electric loading, economic pressures to maximize the use of the grid, and the engineering responses to blackouts that upgrade the system. Mitigation of blackout risk should account for dynamical effects in complex self-organized critical systems. For example, some methods of suppressing small blackouts could ultimately increase the risk of large blackouts.

  20. Proposal on a sustainable strategy to avoid point source pollution of water with plant protection products.

    PubMed

    Mestdagh, Inge; Bonicelli, Bernard; Laplana, Ramon; Roettele, Manfred

    2009-01-01

    Based on the results and lessons learned from the TOPPS project (Training the Operators to prevent Pollution from Point Sources), a proposal on a sustainable strategy to avoid point source pollution from Plant Protection Products (PPPs) was made. Within this TOPPS project (2005-2008), stakeholders were interviewed and research and analysis were done in 6 pilot catchment areas (BE, FR, DE, DK, IT, PL). Next, there was a repeated survey on operators' perception and opinion to measure changes resulting from TOPPS activities and good and bad practices were defined based on the Best Management Practices (risk analysis). Aim of the proposal is to suggest a strategy considering the differences between countries which can be implemented on Member State level in order to avoid PPP pollution of water through point sources. The methodology used for the up-scaLing proposal consists of the analysis of the current situation, a gap analysis, a consistency analysis and organisational structures for implementation. The up-scaling proposal focuses on the behaviour of the operators, on the equipment and infrastructure available with the operators. The proposal defines implementation structures to support correct behaviour through the development and updating of Best Management Practices (BMPs) and through the transfer and the implementation of these BMPs. Next, the proposal also defines requirements for the improvement of equipment and infrastructure based on the defined key factors related to point source pollution. It also contains cost estimates for technical and infrastructure upgrades to comply with BMPs.

Top