Thermodynamic analysis of performance improvement by reheat on the CO2 transcritical power cycle
NASA Astrophysics Data System (ADS)
Tuo, Hanfei
2012-06-01
The CO2 transcritical rankine power cycle has been widely investigated recently, because of its better temperature glide matching between sensible heat source and working fluid in vapor generator, and its desirable qualities, such as moderate critical point, little environment impact and low cost. A reheat CO2 transcritical power cycle with two stage expansion is presented to improve baseline cycle performance in this paper. Energy and exergy analysis are carried out to investigate effects of important parameters on cycle performance. The main results show that reheat cycle performance is sensitive to the variation of medium pressures and the optimum medium pressures exist for maximizing work output and thermal efficiency, respectively. Reheat cycle is compared to baseline cycle under the same conditions. More significant improvements by reheat are obtained at lower turbine inlet temperatures and larger high cycle pressure. Work output improvement is much higher than thermal efficiency improvement, because extra waste heat is required to reheat CO2. Based on second law analysis, exergy efficiency of reheat cycle is also higher than that of baseline cycle, because more useful work is converted from waste heat. Reheat with two stage expansion has great potential to improve thermal efficiency and especially net work output of a CO2 transcritical power cycle using a low-grade heat source.
Performance tests of a two phase ejector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrell, G.S.; Kornhauser, A.A.
1995-12-31
The ejector expansion refrigeration cycle is a modified vapor compression cycle in which a two phase ejector is used to recover a portion of the work otherwise lost in the expansion valve. The ejector improves cycle performance by increasing compressor inlet pressure and by lowering the quality of liquid entering the evaporator. Theoretically, a cooling COP improvement of approximately 23% is achievable for a typical refrigerating cycle and an ideal ejector. If the ejector performed as well as typical single phase ejectors an improvement of 12% could be achieved. Previous tests have demonstrated a smaller 3.7% improvement; the difference ismore » in the poor performance of the two phase ejector. The purpose of this research is to understand the operating characteristics of the two phase ejector and to devise design improvements. A two phase ejector test rig has been constructed and tested. Preliminary data show performance superior to previously tested two phase ejectors, but still inferior to single phase ejectors. Ejector performance corresponds to refrigeration cycle COP improvements ranging from 3.9% to 7.6%.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... Competition Throughout the Life Cycle of Major Defense Acquisition Programs AGENCY: Defense Acquisition... subcontract level of the MDAP throughout its life cycle as a means to improve contractor performance; and (2...) throughout the program life cycle as a means to improve contractor performance; and (ii) Document the...
Li Anode Technology for Improved Performance
NASA Technical Reports Server (NTRS)
Chen, Tuqiang
2011-01-01
A novel, low-cost approach to stabilization of Li metal anodes for high-performance rechargeable batteries was developed. Electrolyte additives are selected and used in Li cell electrolyte systems, promoting formation of a protective coating on Li metal anodes for improved cycle and safety performance. Li batteries developed from the new system will show significantly improved battery performance characteristics, including energy/power density, cycle/ calendar life, cost, and safety.
Enhancing the performance of gastrointestinal tumour board by improving documentation.
Alsuhaibani, Roaa Saleh; Alzahrani, Hajer; Algwaiz, Ghada; Alfarhan, Haneen; Alolayan, Ashwaq; Abdelhafiz, Nafisa; Ali, Yosra; Jazieh, Abdul Rahman
2018-01-01
Tumour board contributes to providing better patient care by using a multidisciplinary team approach. In the efforts of evaluating the performance of the gastrointestinal tumour board at our institution, it was difficult to assess past performance due to lack of proper use of standardised documentation tool. This project aimed at improving adherence to the documentation tool and its recommendations in order to obtain performance measures for the tumour board. A multidisciplinary team and a plan were developed to improve documentation. Four rapid improvement cycles, Plan-Do-Study-Act (PDSA) cycles, were conducted. The first cycle focused on updating the case discussion summary form (CDSF) based on experts' input and previous identified deficiencies to enhance documentation and improve performance. The second PDSA cycle aimed at incorporating the CDSF into the electronic medical records system and assessing its functionality. The third cycle was to orient and train staff on using the form and launching it. The fourth PDSA cycle aimed at assessing the ability to obtain tumour board performance measures. Adherence to completion of the CDSF improved from 82% (baseline) to 94% after the fourth PDSA cycle. Over 104 consecutive cases discussed in the tumour board between January and July 2016 and 76 cases discussed in 2015, results were as follows: adherence to National Comprehensive Cancer Network guidelines in 2016 was observed in 141 (95%) recommendations, while it was observed in 90 (92%) recommendations in 2015. Changes in the management plans were observed in 37 (36%) cases in 2016 and in 6 (8%) cases in 2015. Regarding tumour board recommendations, 87% were done within 3 months of tumour board discussion in 2016, while 69% were done in 2015. Implementing electronic standardised documentation tool improved communication among the team and enabled getting accurate data about performance measures of the tumour board with positive impact on healthcare process and outcomes.
Enhancing the performance of gastrointestinal tumour board by improving documentation
Alsuhaibani, Roaa Saleh; Alzahrani, Hajer; Algwaiz, Ghada; Alfarhan, Haneen; Alolayan, Ashwaq; Abdelhafiz, Nafisa; Ali, Yosra; Jazieh, Abdul Rahman
2018-01-01
Tumour board contributes to providing better patient care by using a multidisciplinary team approach. In the efforts of evaluating the performance of the gastrointestinal tumour board at our institution, it was difficult to assess past performance due to lack of proper use of standardised documentation tool. This project aimed at improving adherence to the documentation tool and its recommendations in order to obtain performance measures for the tumour board. A multidisciplinary team and a plan were developed to improve documentation. Four rapid improvement cycles, Plan–Do–Study–Act (PDSA) cycles, were conducted. The first cycle focused on updating the case discussion summary form (CDSF) based on experts’ input and previous identified deficiencies to enhance documentation and improve performance. The second PDSA cycle aimed at incorporating the CDSF into the electronic medical records system and assessing its functionality. The third cycle was to orient and train staff on using the form and launching it. The fourth PDSA cycle aimed at assessing the ability to obtain tumour board performance measures. Adherence to completion of the CDSF improved from 82% (baseline) to 94% after the fourth PDSA cycle. Over 104 consecutive cases discussed in the tumour board between January and July 2016 and 76 cases discussed in 2015, results were as follows: adherence to National Comprehensive Cancer Network guidelines in 2016 was observed in 141 (95%) recommendations, while it was observed in 90 (92%) recommendations in 2015. Changes in the management plans were observed in 37 (36%) cases in 2016 and in 6 (8%) cases in 2015. Regarding tumour board recommendations, 87% were done within 3 months of tumour board discussion in 2016, while 69% were done in 2015. Implementing electronic standardised documentation tool improved communication among the team and enabled getting accurate data about performance measures of the tumour board with positive impact on healthcare process and outcomes. PMID:29610771
Altmann, Lori J. P.; Stegemöller, Elizabeth; Hazamy, Audrey A.; Wilson, Jonathan P.; Okun, Michael S.; McFarland, Nikolaus R.; Shukla, Aparna Wagle; Hass, Chris J.
2015-01-01
Background When performing two tasks at once, a dual task, performance on one or both tasks typically suffers. People with Parkinson’s disease (PD) usually experience larger dual task decrements on motor tasks than healthy older adults (HOA). Our objective was to investigate the decrements in cycling caused by performing cognitive tasks with a range of difficulty in people with PD and HOAs. Methods Twenty-eight participants with Parkinson’s disease and 20 healthy older adults completed a baseline cycling task with no secondary tasks and then completed dual task cycling while performing 12 tasks from six cognitive domains representing a wide range of difficulty. Results Cycling was faster during dual task conditions than at baseline, and was significantly faster for six tasks (all p<.02) across both groups. Cycling speed improved the most during the easiest cognitive tasks, and cognitive performance was largely unaffected. Cycling improvement was predicted by task difficulty (p<.001). People with Parkinson’s disease cycled slower (p<.03) and showed reduced dual task benefits (p<.01) than healthy older adults. Conclusions Unexpectedly, participants’ motor performance improved during cognitive dual tasks, which cannot be explained in current models of dual task performance. To account for these findings, we propose a model integrating dual task and acute exercise approaches which posits that cognitive arousal during dual tasks increases resources to facilitate motor and cognitive performance, which is subsequently modulated by motor and cognitive task difficulty. This model can explain both the improvement observed on dual tasks in the current study and more typical dual task findings in other studies. PMID:25970607
NASA Astrophysics Data System (ADS)
Gu, Rui
Vapor compression cycles are widely used in heating, refrigerating and air-conditioning. A slight performance improvement in the components of a vapor compression cycle, such as the compressor, can play a significant role in saving energy use. However, the complexity and cost of these improvements can block their application in the market. Modifying the conventional cycle configuration can offer a less complex and less costly alternative approach. Economizing is a common modification for improving the performance of the refrigeration cycle, resulting in decreasing the work required to compress the gas per unit mass. Traditionally, economizing requires multi-stage compressors, the cost of which has restrained the scope for practical implementation. Compressors with injection ports, which can be used to inject economized refrigerant during the compression process, introduce new possibilities for economization with less cost. This work focuses on computationally investigating a refrigeration system performance with two-phase fluid injection, developing a better understanding of the impact of injected refrigerant quality on refrigeration system performance as well as evaluating the potential COP improvement that injection provides based on refrigeration system performance provided by Copeland.
Improvements to the ejector expansion refrigeration cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menegay, P.; Kornhauser, A.A.
1996-12-31
The ejector expansion refrigeration cycle (EERC) is a variant of the standard vapor compression cycle in which an ejector is used to recover part of the work that would otherwise be lost in the expansion valve. In initial testing EERC performance was poor, mainly due to thermodynamic non-equilibrium conditions in the ejector motive nozzle. Modifications were made to correct this problem, and significant performance improvements were found.
Pozzi, Lara; Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Lepers, Romuald; Rüst, Christoph Alexander
2014-01-01
The purpose of this study was to examine the sex and age-related differences in performance in a draft-legal ultra-cycling event. Age-related changes in performance across years were investigated in the 24-hour draft-legal cycling event held in Schötz, Switzerland, between 2000 and 2011 using multi-level regression analyses including age, repeated participation and environmental temperatures as co-variables. For all finishers, the age of peak cycling performance decreased significantly (β = -0.273, p = 0.036) from 38 ± 10 to 35 ± 6 years in females but remained unchanged (β = -0.035, p = 0.906) at 41.0 ± 10.3 years in males. For the annual fastest females and males, the age of peak cycling performance remained unchanged at 37.3 ± 8.5 and 38.3 ± 5.4 years, respectively. For all female and male finishers, males improved significantly (β = 7.010, p = 0.006) the cycling distance from 497.8 ± 219.6 km to 546.7 ± 205.0 km whereas females (β = -0.085, p = 0.987) showed an unchanged performance of 593.7 ± 132.3 km. The mean cycling distance achieved by the male winners of 960.5 ± 51.9 km was significantly (p < 0.001) greater than the distance covered by the female winners with 769.7 ± 65.7 km but was not different between the sexes (p > 0.05). The sex difference in performance for the annual winners of 19.7 ± 7.8% remained unchanged across years (p > 0.05). The achieved cycling distance decreased in a curvilinear manner with advancing age. There was a significant age effect (F = 28.4, p < 0.0001) for cycling performance where the fastest cyclists were in age group 35-39 years. In this 24-h cycling draft-legal event, performance in females remained unchanged while their age of peak cycling performance decreased and performance in males improved while their age of peak cycling performance remained unchanged. The annual fastest females and males were 37.3 ± 8.5 and 38.3 ± 5.4 years old, respectively. The sex difference for the fastest finishers was ~20%. It seems that women were not able to profit from drafting to improve their ultra-cycling performance.
Meier, Frederick A; Souers, Rhona J; Howanitz, Peter J; Tworek, Joseph A; Perrotta, Peter L; Nakhleh, Raouf E; Karcher, Donald S; Bashleben, Christine; Darcy, Teresa P; Schifman, Ron B; Jones, Bruce A
2015-06-01
Many production systems employ standardized statistical monitors that measure defect rates and cycle times, as indices of performance quality. Clinical laboratory testing, a system that produces test results, is amenable to such monitoring. To demonstrate patterns in clinical laboratory testing defect rates and cycle time using 7 College of American Pathologists Q-Tracks program monitors. Subscribers measured monthly rates of outpatient order-entry errors, identification band defects, and specimen rejections; median troponin order-to-report cycle times and rates of STAT test receipt-to-report turnaround time outliers; and critical values reporting event defects, and corrected reports. From these submissions Q-Tracks program staff produced quarterly and annual reports. These charted each subscriber's performance relative to other participating laboratories and aggregate and subgroup performance over time, dividing participants into best and median performers and performers with the most room to improve. Each monitor's patterns of change present percentile distributions of subscribers' performance in relation to monitoring durations and numbers of participating subscribers. Changes over time in defect frequencies and the cycle duration quantify effects on performance of monitor participation. All monitors showed significant decreases in defect rates as the 7 monitors ran variously for 6, 6, 7, 11, 12, 13, and 13 years. The most striking decreases occurred among performers who initially had the most room to improve and among subscribers who participated the longest. All 7 monitors registered significant improvement. Participation effects improved between 0.85% and 5.1% per quarter of participation. Using statistical quality measures, collecting data monthly, and receiving reports quarterly and yearly, subscribers to a comparative monitoring program documented significant decreases in defect rates and shortening of a cycle time for 6 to 13 years in all 7 ongoing clinical laboratory quality monitors.
2014-01-01
Background The purpose of this study was to examine the sex and age-related differences in performance in a draft-legal ultra-cycling event. Methods Age-related changes in performance across years were investigated in the 24-hour draft-legal cycling event held in Schötz, Switzerland, between 2000 and 2011 using multi-level regression analyses including age, repeated participation and environmental temperatures as co-variables. Results For all finishers, the age of peak cycling performance decreased significantly (β = −0.273, p = 0.036) from 38 ± 10 to 35 ± 6 years in females but remained unchanged (β = −0.035, p = 0.906) at 41.0 ± 10.3 years in males. For the annual fastest females and males, the age of peak cycling performance remained unchanged at 37.3 ± 8.5 and 38.3 ± 5.4 years, respectively. For all female and male finishers, males improved significantly (β = 7.010, p = 0.006) the cycling distance from 497.8 ± 219.6 km to 546.7 ± 205.0 km whereas females (β = −0.085, p = 0.987) showed an unchanged performance of 593.7 ± 132.3 km. The mean cycling distance achieved by the male winners of 960.5 ± 51.9 km was significantly (p < 0.001) greater than the distance covered by the female winners with 769.7 ± 65.7 km but was not different between the sexes (p > 0.05). The sex difference in performance for the annual winners of 19.7 ± 7.8% remained unchanged across years (p > 0.05). The achieved cycling distance decreased in a curvilinear manner with advancing age. There was a significant age effect (F = 28.4, p < 0.0001) for cycling performance where the fastest cyclists were in age group 35–39 years. Conclusion In this 24-h cycling draft-legal event, performance in females remained unchanged while their age of peak cycling performance decreased and performance in males improved while their age of peak cycling performance remained unchanged. The annual fastest females and males were 37.3 ± 8.5 and 38.3 ± 5.4 years old, respectively. The sex difference for the fastest finishers was ~20%. It seems that women were not able to profit from drafting to improve their ultra-cycling performance. PMID:24883191
1993-12-01
5-6 5.6.1 Large Cycle Slip Simulation ............................. 5-7 5.6.2 Small Cycle Slip Simulation ........................... 5-9...Appendix J. Small Cycle Slip Simulation Results ............................. J-1 Bibliography ........................................................ BIB-I...when subjected to large and small cycle slips. Results of the simulations indicate that the PNRS can provide an improved navigation solution over
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braase, Lori
Develop advanced nuclear fuel cycle separation and waste management technologies that improve current fuel cycle performance and enable a sustainable fuel cycle, with minimal processing, waste generation, and potential for material diversion.
Thermodynamic Study of Multi Pressure HRSG in Gas/Steam Combined Cycle Power Plant
NASA Astrophysics Data System (ADS)
Sharma, Meeta; Singh, Onkar
2018-01-01
Combined cycle power plants have a combination of gas based topping cycle and steam based bottoming cycle through the use of Heat Recovery Steam Generator (HRSG). These HRSG may be either of single pressure (SP) or dual pressure (DP) or multiple pressure type. Here in this study thermodynamic analysis is carried out for optimal performance of HRSG using different types of HRSG layout for combined cycle efficiency improvement. Performance of single pressure HRSG and dual pressure HRSG, utilized in gas/steam combined cycle is analyzed and presented here. In comparison to single pressure, dual pressure HRSG offers 10 to 15% higher reduction in stack temperature due to greater heat recovery and thus improved plant efficiency.
Advanced binary geothermal power plants: Limits of performance
NASA Astrophysics Data System (ADS)
Bliem, C. J.; Mines, G. L.
1991-01-01
The Heat Cycle Research Program is investigating potential improvements to power cycles utilizing moderate temperature geothermal resources to produce electrical power. Investigations have specifically examined Rankine cycle binary power systems. Binary Rankine cycles are more efficient than the flash steam cycles at moderate resource temperature, achieving a higher net brine effectiveness. At resource conditions similar to those at the Heber binary plant, it has been shown that mixtures of saturated hydrocarbons (alkanes) or halogenated hydrocarbons operating in a supercritical Rankine cycle gave improved performance over Rankine cycles with the pure working fluids executing single or dual boiling cycles or supercritical cycles. Recently, other types of cycles have been proposed for binary geothermal service. The feasible limits on efficiency of a plant given practical limits on equipment performance is explored and the methods used in these advanced concept plants to achieve the maximum possible efficiency are discussed. (Here feasible is intended to mean reasonably achievable and not cost effective.) No direct economic analysis was made because of the sensitivity of economic results to site specific input. The limit of performance of three advanced plants were considered. The performance predictions were taken from the developers of each concept. The advanced plants considered appear to be approaching the feasible limit of performance. Ultimately, the plant designer must weigh the advantages and disadvantages of the the different cycles to find the best plant for a given service. In addition, a standard is presented of comparison of the work which has been done in the Heat Cycle Research Program and in the industrial sector by Exergy, Inc. and Polythermal Technologies.
Harrington, Ann Tokay; McRae, Calum G. A.; Lee, Samuel C. K.
2012-01-01
Introduction. Adolescents with cerebral palsy (CP) often have difficulty participating in exercise at intensities necessary to improve cardiovascular fitness. Functional electrical stimulation- (FES-) assisted cycling is proposed as a form of exercise for adolescents with CP. The aims of this paper were to adapt methods and assess the feasibility of applying FES cycling technology in adolescents with CP, determine methods of performing cycling tests in adolescents with CP, and evaluate the immediate effects of FES assistance on cycling performance. Materials/Methods. Four participants (12–14 years old; GMFCS levels III-IV) participated in a case-based pilot study of FES-assisted cycling in which bilateral quadriceps muscles were activated using surface electrodes. Cycling cadence, power output, and heart rate were collected. Results. FES-assisted cycling was well tolerated (n = 4) and cases are presented demonstrating increased cadence (2–43 rpm), power output (19–70%), and heart rates (4-5%) and decreased variability (8–13%) in cycling performance when FES was applied, compared to volitional cycling without FES assistance. Some participants (n = 2) required the use of an auxiliary hub motor for assistance. Conclusions. FES-assisted cycling is feasible for individuals with CP and may lead to immediate improvements in cycling performance. Future work will examine the potential for long-term fitness gains using this intervention. PMID:22685479
An improved wave rotor refrigerator using an outside gas flow for recycling the expansion work
NASA Astrophysics Data System (ADS)
Zhao, J.; Hu, D.
2017-03-01
To overcome the bottleneck of traditional gas wave refrigeration, an improved wave rotor refrigerator (WRR) cycle has been proposed, in which the expansion work was recycled during the process of refrigeration. Thermodynamic analysis of the two cycles shows that the refrigeration efficiency of the improved WRR cycle has been greatly increased compared with the traditional WRR. The performance of an improved WRR was investigated by adjusting the major operational parameters, such as the rotational speed of the wave rotor, port size, and inflow overpressure. The experimental results show that pressure loss can be reduced by nearly 40 % in this improved refrigeration system. Meanwhile, a two-dimensional numerical simulation was performed to understand the wave interactions that take place inside the rotor channels.
NASA Astrophysics Data System (ADS)
Lin, Jyun-Hao; Huang, Shyh-Jer; Su, Yan-Kuin
2014-01-01
A simple thermal cycle annealing (TCA) process was used to improve the quality of GaN grown on a Si substrate. The X-ray diffraction (XRD) and etch pit density (EPD) results revealed that using more process cycles, the defect density cannot be further reduced. However, the performance of GaN-based metal-semiconductor-metal (MSM) photodiodes (PDs) prepared on Si substrates showed significant improvement. With a two-cycle TCA process, it is found that the dark current of the device was only 1.46 × 10-11 A, and the photo-to-dark-current contrast ratio was about 1.33 × 105 at 5 V. Also, the UV/visible rejection ratios can reach as high as 1077.
Paquette, Max R; Peel, Shelby A; Smith, Ross E; Temme, Mark; Dwyer, Jeffrey N
2017-11-29
There are many different types of aerobic cross-training modalities currently available. It is important to consider the effects that these different modalities have on running performance and injury risks. The purpose of this study was to compare movement quality, running economy and performance, injury-related biomechanical variables and, hip muscle strength before and after training with different cross-training modalities in high school runners. Thirty-one high school male runners trained for four weeks in one of three cross-training modalities, in addition to a running-only (RUN, n=9) group, for which training sessions replaced two easy runs per week: cycling (CYCLE; n=6), indoor elliptical (ELLIP; n=7) and, outdoor elliptical bike (EBIKE; n=9). Functional movement screen (FMS), running economy (RE), 3,000m performance, hip kinematics, hip muscle strength were assessed. Paired t-tests and Cohen's d effect sizes were used to assess mean differences for each variable before and after training within each group. EBIKE training was the only modality that improved FMS scores (d = 1.36) and RE before and after training (d = 0.48). All groups showed improvements in 3,000m performance but large effects were only found for the CYCLE (d = 1.50) and EBIKE (d = 1.41) groups. RUN (d = 1.25), CYCLE (d = 1.17) and, EBIKE (d = 0.82) groups showed improvements in maximal hip extensor strength. Outdoor cycling and elliptical bike cross-training may be the most effective cross-training modalities to incorporate in early season training to improve running performance in high school runners.
Electrolytes for Use in High Energy Lithium-ion Batteries with Wide Operating Temperature Range
NASA Technical Reports Server (NTRS)
Smart, Marshall C.; Ratnakumar, B. V.; West, W. C.; Whitcanack, L. D.; Huang, C.; Soler, J.; Krause, F. C.
2012-01-01
Met programmatic milestones for program. Demonstrated improved performance with wide operating temperature electrolytes containing ester co-solvents (i.e., methyl butyrate) containing electrolyte additives in A123 prototype cells: Previously demonstrated excellent low temperature performance, including 11C rates at -30 C and the ability to perform well down to -60 C. Excellent cycle life at room temperature has been displayed, with over 5,000 cycles being demonstrated. Good high temperature cycle life performance has also been achieved. Demonstrated improved performance with methyl propionate-containing electrolytes in large capacity prototype cells: Demonstrated the wide operating temperature range capability in large cells (12 Ah), successfully scaling up technology from 0.25 Ah size cells. Demonstrated improved performance at low temperature and good cycle life at 40 C with methyl propionate-based electrolyte containing increasing FEC content and the use of LiBOB as an additive. Utilized three-electrode cells to investigate the electrochemical characteristics of high voltage systems coupled with wide operating temperature range electrolytes: From Tafel polarization measurements on each electrode, it is evident the NMC-based cathode displays poor lithium kinetics (being the limiting electrode). The MB-based formulations containing LiBOB delivered the best rate capability at low temperature, which is attributed to improved cathode kinetics. Whereas, the use of lithium oxalate as an additive lead to the highest reversible capacity and lower irreversible losses.
Wang, Jiexi; Zhang, Qiaobao; Li, Xinhai; Wang, Zhixing; Guo, Huajun; Xu, Daguo; Zhang, Kaili
2014-08-14
To improve the cycle performance of LiMn2O4 at elevated temperature, a graphite layer is introduced to directly cover the surface of a commercial LiMn2O4-based electrode via room-temperature DC magnetron sputtering. The as-modified cathodes display improved capacity retention as compared to the bare LiMn2O4 cathode (BLMO) at 55 °C. When sputtering graphite for 30 min, the sample shows the best cycling performance at 55 °C, maintaining 96.2% capacity retention after 200 cycles. Reasons with respect to the graphite layer for improving the elevated-temperature performance of LiMn2O4 are systematically investigated via the methods of cyclic voltammetry, electrochemical impedance spectroscopy, X-ray photoelectron spectrometry, scanning and transmission electron microscopy, X-ray diffraction and inductively coupled plasma-atomic emission spectrometry. The results demonstrate that the graphite coated LiMn2O4 cathode has much less increased electrode polarization and electrochemical impedance than BLMO during the elevated-temperature cycling process. Furthermore, the graphite layer is able to alleviate the severe dissolution of manganese ions into the electrolyte and mitigate the morphological and structural degradation of LiMn2O4 during cycling. A model for the electrochemical kinetics process is also suggested for explaining the roles of the graphite layer in suppressing the Mn dissolution.
Specific aspects of contemporary triathlon: implications for physiological analysis and performance.
Bentley, David J; Millet, Grégoire P; Vleck, Verónica E; McNaughton, Lars R
2002-01-01
Triathlon competitions are performed over markedly different distances and under a variety of technical constraints. In 'standard-distance' triathlons involving 1.5km swim, 40km cycling and 10km running, a World Cup series as well as a World Championship race is available for 'elite' competitors. In contrast, 'age-group' triathletes may compete in 5-year age categories at a World Championship level, but not against the elite competitors. The difference between elite and age-group races is that during the cycle stage elite competitors may 'draft' or cycle in a sheltered position; age-group athletes complete the cycle stage as an individual time trial. Within triathlons there are a number of specific aspects that make the physiological demands different from the individual sports of swimming, cycling and running. The physiological demands of the cycle stage in elite races may also differ compared with the age-group format. This in turn may influence performance during the cycle leg and subsequent running stage. Wetsuit use and drafting during swimming (in both elite and age-group races) result in improved buoyancy and a reduction in frontal resistance, respectively. Both of these factors will result in improved performance and efficiency relative to normal pool-based swimming efforts. Overall cycling performance after swimming in a triathlon is not typically affected. However, it is possible that during the initial stages of the cycle leg the ability of an athlete to generate the high power outputs necessary for tactical position changes may be impeded. Drafting during cycling results in a reduction in frontal resistance and reduced energy cost at a given submaximal intensity. The reduced energy expenditure during the cycle stage results in an improvement in running, so an athlete may exercise at a higher percentage of maximal oxygen uptake. In elite triathlon races, the cycle courses offer specific physiological demands that may result in different fatigue responses when compared with standard time-trial courses. Furthermore, it is possible that different physical and physiological characteristics may make some athletes more suited to races where the cycle course is either flat or has undulating sections. An athlete's ability to perform running activity after cycling, during a triathlon, may be influenced by the pedalling frequency and also the physiological demands of the cycle stage. The technical features of elite and age-group triathlons together with the physiological demands of longer distance events should be considered in experimental design, training practice and also performance diagnosis of triathletes.
NASA Astrophysics Data System (ADS)
Dagger, Tim; Lürenbaum, Constantin; Schappacher, Falko M.; Winter, Martin
2017-02-01
A modified self-extinguishing time (SET) device which enhances the reproducibility of the results is presented. Pentafluoro(phenoxy)cyclotriphosphazene (FPPN) is investigated as flame retardant electrolyte additive for lithium ion batteries (LIBs) in terms of thermal stability and electrochemical performance. SET measurements and adiabatic reaction calorimetry are applied to determine the flammability and the reactivity of a standard LIB electrolyte containing 5% FPPN. The results reveal that the additive-containing electrolyte is nonflammable for 10 s whereas the commercially available reference electrolyte inflames instantaneously after 1 s of ignition. The onset temperature of the safety enhanced electrolyte is delayed by ≈ 21 °C. Compatibility tests in half cells show that the electrolyte is reductively stable while the cyclic voltammogram indicates oxidative decomposition during the first cycle. Cycling experiments in full cells show improved cycling performance and rate capability, which can be attributed to cathode passivation during the first cycle. Post-mortem analysis of the electrolyte by gas chromatography-mass spectrometry confirms the presence of the additive in high amounts after 501 cycles which ensures enhanced safety of the electrolyte. The investigations present FPPN as stable electrolyte additive that improves the intrinsic safety of the electrolyte and its cycling performance at the same time.
Utilization of waste heat in trucks for increased fuel economy
NASA Technical Reports Server (NTRS)
Leising, C. J.; Purohit, G. P.; Degrey, S. P.; Finegold, J. G.
1978-01-01
The waste heat utilization concepts include preheating, regeneration, turbocharging, turbocompounding, and Rankine engine compounding. Predictions are based on fuel-air cycle analyses, computer simulation, and engine test data. All options are evaluated in terms of maximum theoretical improvements, but the Diesel and adiabatic Diesel are also compared on the basis of maximum expected improvement and expected improvement over a driving cycle. The study indicates that Diesels should be turbocharged and aftercooled to the maximum possible level. The results reveal that Diesel driving cycle performance can be increased by 20% through increased turbocharging, turbocompounding, and Rankine engine compounding. The Rankine engine compounding provides about three times as much improvement as turbocompounding but also costs about three times as much. Performance for either can be approximately doubled if applied to an adiabatic Diesel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasch, James Jay
A method of resolving a balanced condition that generates control parameters for start-up and steady state operating points and various component and cycle performances for a closed split flow recompression cycle system. The method provides for improved control of a Brayton cycle thermal to electrical power conversion system. The method may also be used for system design, operational simulation and/or parameter prediction.
2nd Generation Reusable Launch Vehicle (2G RLV). Revised
NASA Technical Reports Server (NTRS)
Matlock, Steve; Sides, Steve; Kmiec, Tom; Arbogast, Tim; Mayers, Tom; Doehnert, Bill
2001-01-01
This is a revised final report and addresses all of the work performed on this program. Specifically, it covers vehicle architecture background, definition of six baseline engine cycles, reliability baseline (space shuttle main engine QRAS), and component level reliability/performance/cost for the six baseline cycles, and selection of 3 cycles for further study. This report further addresses technology improvement selection and component level reliability/performance/cost for the three cycles selected for further study, as well as risk reduction plans, and recommendation for future studies.
Thermodynamic analysis of a new dual evaporator CO2 transcritical refrigeration cycle
NASA Astrophysics Data System (ADS)
Abdellaoui, Ezzaalouni Yathreb; Kairouani, Lakdar Kairouani
2017-03-01
In this work, a new dual-evaporator CO2 transcritical refrigeration cycle with two ejectors is proposed. In this new system, we proposed to recover the lost energy of condensation coming off the gas cooler and operate the refrigeration cycle ejector free and enhance the system performance and obtain dual-temperature refrigeration simultaneously. The effects of some key parameters on the thermodynamic performance of the modified cycle are theoretically investigated based on energetic and exergetic analysis. The simulation results for the modified cycle indicate more effective system performance improvement than the single ejector in the CO2 vapor compression cycle using ejector as an expander ranging up to 46%. The exergetic analysis for this system is made. The performance characteristics of the proposed cycle show its promise in dual-evaporator refrigeration system.
Auinger, Hans-Jürgen; Schönleben, Manfred; Lehermeier, Christina; Schmidt, Malthe; Korzun, Viktor; Geiger, Hartwig H; Piepho, Hans-Peter; Gordillo, Andres; Wilde, Peer; Bauer, Eva; Schön, Chris-Carolin
2016-11-01
Genomic prediction accuracy can be significantly increased by model calibration across multiple breeding cycles as long as selection cycles are connected by common ancestors. In hybrid rye breeding, application of genome-based prediction is expected to increase selection gain because of long selection cycles in population improvement and development of hybrid components. Essentially two prediction scenarios arise: (1) prediction of the genetic value of lines from the same breeding cycle in which model training is performed and (2) prediction of lines from subsequent cycles. It is the latter from which a reduction in cycle length and consequently the strongest impact on selection gain is expected. We empirically investigated genome-based prediction of grain yield, plant height and thousand kernel weight within and across four selection cycles of a hybrid rye breeding program. Prediction performance was assessed using genomic and pedigree-based best linear unbiased prediction (GBLUP and PBLUP). A total of 1040 S 2 lines were genotyped with 16 k SNPs and each year testcrosses of 260 S 2 lines were phenotyped in seven or eight locations. The performance gap between GBLUP and PBLUP increased significantly for all traits when model calibration was performed on aggregated data from several cycles. Prediction accuracies obtained from cross-validation were in the order of 0.70 for all traits when data from all cycles (N CS = 832) were used for model training and exceeded within-cycle accuracies in all cases. As long as selection cycles are connected by a sufficient number of common ancestors and prediction accuracy has not reached a plateau when increasing sample size, aggregating data from several preceding cycles is recommended for predicting genetic values in subsequent cycles despite decreasing relatedness over time.
ERIC Educational Resources Information Center
Park, Sandra; Takahashi, Sola
2013-01-01
90-Day Cycles are a disciplined and structured form of inquiry designed to produce and test knowledge syntheses, prototyped processes, or products in support of improvement work. With any type of activity, organizations inevitably encounter roadblocks to improving performance and outcomes. These barriers might include intractable problems at…
Cao, Peng-Fei; Naguib, Michael; Du, Zhijia; ...
2018-01-04
Although significant progress has been made in improving cycling performance of silicon-based electrodes, few studies have been performed on the architecture effect on polymer binder performance for lithium-ion batteries. A systematic study on the relationship between polymer architectures and binder performance is especially useful in designing synthetic polymer binders. In this paper, a graft block copolymer with readily tunable architecture parameters is synthesized and tested as the polymer binder for the high-mass loading silicon (15 wt %)/graphite (73 wt %) composite electrode (active materials >2.5 mg/cm 2). With the same chemical composition and functional group ratio, the graft block copolymermore » reveals improved cycling performance in both capacity retention (495 mAh/g vs 356 mAh/g at 100th cycle) and Coulombic efficiency (90.3% vs 88.1% at first cycle) than the physical mixing of glycol chitosan (GC) and lithium polyacrylate (LiPAA). Galvanostatic results also demonstrate the significant impacts of different architecture parameters of graft copolymers, including grafting density and side chain length, on their ultimate binder performance. Finally, by simply changing the side chain length of GC-g-LiPAA, the retaining delithiation capacity after 100 cycles varies from 347 mAh/g to 495 mAh/g.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Peng-Fei; Naguib, Michael; Du, Zhijia
Although significant progress has been made in improving cycling performance of silicon-based electrodes, few studies have been performed on the architecture effect on polymer binder performance for lithium-ion batteries. A systematic study on the relationship between polymer architectures and binder performance is especially useful in designing synthetic polymer binders. In this paper, a graft block copolymer with readily tunable architecture parameters is synthesized and tested as the polymer binder for the high-mass loading silicon (15 wt %)/graphite (73 wt %) composite electrode (active materials >2.5 mg/cm 2). With the same chemical composition and functional group ratio, the graft block copolymermore » reveals improved cycling performance in both capacity retention (495 mAh/g vs 356 mAh/g at 100th cycle) and Coulombic efficiency (90.3% vs 88.1% at first cycle) than the physical mixing of glycol chitosan (GC) and lithium polyacrylate (LiPAA). Galvanostatic results also demonstrate the significant impacts of different architecture parameters of graft copolymers, including grafting density and side chain length, on their ultimate binder performance. Finally, by simply changing the side chain length of GC-g-LiPAA, the retaining delithiation capacity after 100 cycles varies from 347 mAh/g to 495 mAh/g.« less
Triple-effect absorption chiller cycle: A step beyond double-effect cycles
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVault, R.C.
1990-01-01
Many advanced'' absorption cycles have been proposed during the current century. Of the hundreds of absorption cycles which have been patented throughout the world, all commercially manufactured products for air conditioning buildings have been variations of just two basic absorption cycles: single-effect and condenser-coupled double-effect cycles. The relatively low cooling coefficients of performance (COPs) inherent in single-effect and double-effect cycles limits the economic applicability of absorption air conditioners (chillers) in the United States. A triple-effect absorption chiller cycle is discussed. This cycle uses two condensers and two absorbers to achieve the triple effect.'' Depending on the absorption fluids selected, thismore » triple-effect cycle is predicted to improve cooling COPs by 18% to 60% compared with the equivalent double-effect cycle. This performance improvement is obtained without increasing the total amount of heat-transfer surface area needed for the heat exchangers. A comparison between the calculated performances of a double-effect cycle and a triple-effect cycle (both using ammonia-water (NH{sub 3}/H{sub 2}O) as the absorption fluid pair) is presented. The triple-effect cycle is predicted to have an 18% higher cooling COP (1.41 compared with 1.2 for a double-effect), lower pressure (47.70 atm (701 psi) instead of 68.05 atm (1000 psi)), significantly reduced pumping power (less than one-half that of the double-effect cycle), and potentially lower construction cost (33% less total heat exchange needed). Practical implications for this triple-effect cycle are discussed. 16 refs., 5 figs., 1 tab.« less
Singh, Simone Rauscher; Wheeler, John
2012-01-01
Effective revenue cycle management--from appointment scheduling and patient registration at the front end of the revenue cycle to billing and cash collections at the back end--plays a crucial role in hospitals' efforts to improve their financial performance. Using data for 1,397 bond-issuing, not-for-profit US hospitals for 2000 to 2007, this study analyzed the relationship between hospitals' performance at managing the revenue cycle and their profitability and ability to build equity capital. Hospital-level fixed effects regression analysis was used to model four different measures of profitability and equity capital as functions of two key financial indicators of revenue cycle management--amount of patient revenue and speed of revenue collection. The results indicated that higher amounts of patient revenue in relation to a hospital's assets were associated with statistically significant increases in operating and total profit margins, free cash flow, and equity capital (p < 0.01 for all four models); that is, hospitals that generated more patient revenue per dollar of assets invested reported improved financial performance. Likewise, a statistically significant link existed between lower revenue collection periods and all four indicators of hospital financial performance (p < 0.01 for three models; p < 0.05 for one model). Hospitals that collected faster on their patient revenue reported higher profit margins and larger equity values. For revenue cycle managers, these findings represent good news: Streamlining a hospital's management of the patient revenue cycle can advance the organization's financial viability by improving profitability and enabling equity growth.
Advanced reactors and associated fuel cycle facilities: safety and environmental impacts.
Hill, R N; Nutt, W M; Laidler, J J
2011-01-01
The safety and environmental impacts of new technology and fuel cycle approaches being considered in current U.S. nuclear research programs are contrasted to conventional technology options in this paper. Two advanced reactor technologies, the sodium-cooled fast reactor (SFR) and the very high temperature gas-cooled reactor (VHTR), are being developed. In general, the new reactor technologies exploit inherent features for enhanced safety performance. A key distinction of advanced fuel cycles is spent fuel recycle facilities and new waste forms. In this paper, the performance of existing fuel cycle facilities and applicable regulatory limits are reviewed. Technology options to improve recycle efficiency, restrict emissions, and/or improve safety are identified. For a closed fuel cycle, potential benefits in waste management are significant, and key waste form technology alternatives are described. Copyright © 2010 Health Physics Society
High-intensity cycle interval training improves cycling and running performance in triathletes.
Etxebarria, Naroa; Anson, Judith M; Pyne, David B; Ferguson, Richard A
2014-01-01
Effective cycle training for triathlon is a challenge for coaches. We compared the effects of two variants of cycle high-intensity interval training (HIT) on triathlon-specific cycling and running. Fourteen moderately-trained male triathletes ([Formula: see text]O2peak 58.7 ± 8.1 mL kg(-1) min(-1); mean ± SD) completed on separate occasions a maximal incremental test ([Formula: see text]O2peak and maximal aerobic power), 16 × 20 s cycle sprints and a 1-h triathlon-specific cycle followed immediately by a 5 km run time trial. Participants were then pair-matched and assigned randomly to either a long high-intensity interval training (LONG) (6-8 × 5 min efforts) or short high-intensity interval training (SHORT) (9-11 × 10, 20 and 40 s efforts) HIT cycle training intervention. Six training sessions were completed over 3 weeks before participants repeated the baseline testing. Both groups had an ∼7% increase in [Formula: see text]O2peak (SHORT 7.3%, ±4.6%; mean, ±90% confidence limits; LONG 7.5%, ±1.7%). There was a moderate improvement in mean power for both the SHORT (10.3%, ±4.4%) and LONG (10.7%, ±6.8%) groups during the last eight 20-s sprints. There was a small to moderate decrease in heart rate, blood lactate and perceived exertion in both groups during the 1-h triathlon-specific cycling but only the LONG group had a substantial decrease in the subsequent 5-km run time (64, ±59 s). Moderately-trained triathletes should use both short and long high-intensity intervals to improve cycling physiology and performance. Longer 5-min intervals on the bike are more likely to benefit 5 km running performance.
NASA Technical Reports Server (NTRS)
Stochl, R. J.
1979-01-01
The results of an analysis to estimate the performance that could be obtained by using a chemically reacting gas (nitrogen tetroxide) as the working fluid in a closed Brayton cycle are presented. Compared with data for helium as the working fluid, these results indicate efficiency improvements from 4 to 90 percent, depending on turbine inlet temperature, pressures, and gas residence time in heat transfer equipment.
A New, Highly Improved Two-Cycle Engine
NASA Technical Reports Server (NTRS)
Wiesen, Bernard
2008-01-01
The figure presents a cross-sectional view of a supercharged, variable-compression, two-cycle, internal-combustion engine that offers significant advantages over prior such engines. The improvements are embodied in a combination of design changes that contribute synergistically to improvements in performance and economy. Although the combination of design changes and the principles underlying them are complex, one of the main effects of the changes on the overall engine design is reduced (relative to prior two-cycle designs) mechanical complexity, which translates directly to reduced manufacturing cost and increased reliability. Other benefits include increases in the efficiency of both scavenging and supercharging. The improvements retain the simplicity and other advantages of two-cycle engines while affording increases in volumetric efficiency and performance across a wide range of operating conditions that, heretofore have been accessible to four-cycle engines but not to conventionally scavenged two-cycle ones, thereby increasing the range of usefulness of the two-cycle engine into all areas now dominated by the four-cycle engine. The design changes and benefits are too numerous to describe here in detail, but it is possible to summarize the major improvements: Reciprocating Shuttle Inlet Valve The entire reciprocating shuttle inlet valve and its operating gear is constructed as a single member. The shuttle valve is actuated in a lost-motion arrangement in which, at the ends of its stroke, projections on the shuttle valve come to rest against abutments at the ends of grooves in a piston skirt. This shuttle-valve design obviates the customary complex valve mechanism, actuated from an engine crankshaft or camshaft, yet it is effective with every type of two-cycle engine, from small high-speed single cylinder model engines, to large low-speed multiple cylinder engines.
Branched GAX cycle gas fired heat pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, D.C.; Anand, G.; Papar, R.A.
1996-12-31
GAX absorption heat pump cycles are characterized by the Generator Absorber Heat eXchange (GAX) between the high temperature end of the absorber and the low temperature end of the generator. The improved thermodynamic performance of the basic GAX cycle coupled with its mechanical simplicity has attracted substantial interest in using this cycle for gas-cooling. However, to be competitive in a cooling dominated market, the cycle has to achieve high cooling performance and also low installed cost. The Branched GAX (BGAX) cycle promises higher cooling performance using similar components as the basic GAX cycle and an additional solution pump. By increasingmore » the solution flow rate at the hot end of the absorber, the BGAX cycle makes more complete use of the temperature overlap. As a result, less external heat is supplied and higher COPs are obtained. A breadboard prototype of the BGAX cycle has been developed and is now operating. A novel thermosyphon cooled absorber eliminates the need for the outdoor hydronic loop, and reduces cost by 10%. Other component improvements yield another 10% cost reduction. The breadboard prototype has operated for more than 200 hours. Gas cooling COP = 0.87 has been consistently achieved at 30.6 C (87 F) ambient conditions. At the 35 C (95 F) ambient capacity rating condition, a cooling load of 4.5 refrigeration tons was achieved at a cycle COP = 0.95.« less
NASA Technical Reports Server (NTRS)
Matlock, Steve
2001-01-01
This is the final report and addresses all of the work performed on this program. Specifically, it covers vehicle architecture background, definition of six baseline engine cycles, reliability baseline (space shuttle main engine QRAS), and component level reliability/performance/cost for the six baseline cycles, and selection of 3 cycles for further study. This report further addresses technology improvement selection and component level reliability/performance/cost for the three cycles selected for further study, as well as risk reduction plans, and recommendation for future studies.
Performance assessment of an irreversible nano Brayton cycle operating with Maxwell-Boltzmann gas
NASA Astrophysics Data System (ADS)
Açıkkalp, Emin; Caner, Necmettin
2015-05-01
In the last decades, nano-technology has been developed very fast. According to this, nano-cycle thermodynamics should improve with a similar rate. In this paper, a nano-scale irreversible Brayton cycle working with helium is evaluated for different thermodynamic criteria. These are maximum work output, ecological function, ecological coefficient of performance, exergetic performance criteria and energy efficiency. Thermodynamic analysis was performed for these criteria and results were submitted numerically. In addition, these criteria are compared with each other and the most convenient methods for the optimum conditions are suggested.
Harrington, J Timothy; Barash, Harvey L; Day, Sherry; Lease, Joellen
2005-04-15
To develop new processes that assure more reliable, population-based care of fragility fracture patients. A 4-year clinical improvement project was performed in a multispecialty, community practice health system using evidence-based guidelines and rapid cycle process improvement methods (plan-do-study-act cycles). Prior to this project, appropriate osteoporosis care was provided to only 5% of our 1999 hip fracture patients. In 2001, primary physicians were provided prompts about appropriate care (cycle 1), which resulted in improved care for only 20% of patients. A process improvement pilot in 2002 (cycle 2) and full program implementation in 2003 (cycle 3) have assured osteoporosis care for all willing and able patients with any fragility fracture. Altogether, 58% of 2003 fragility fracture patients, including 46% of those with hip fracture, have had a bone measurement, have been assigned to osteoporosis care with their primary physician or a consultant, and are being monitored regularly. Only 19% refused osteoporosis care. Key process improvements have included using orthopedic billings to identify patients, referring patients directly from orthopedics to an osteoporosis care program, organizing care with a nurse manager and process management computer software, assigning patients to primary or consultative physician care based on disease severity, and monitoring adherence to therapy by telephone. Reliable osteoporosis care is achievable by redesigning clinical processes. Performance data motivate physicians to reconsider traditional approaches. Improving the care of osteoporosis and other chronic diseases requires coordinated care across specialty boundaries and health system support.
Round and Round We Go: An "Action" Ride on the Rehearsing and Performing Cycle
ERIC Educational Resources Information Center
Pulman, Mark
2012-01-01
This article discusses the use of action research cycles on a course involving groupwork rehearsing and performance. The aim was to explore various pedagogic aspects of the activities and improve tutor practice. This account of four action research spirals, taking place over a 10-year period of rehearsing and performing, considers their management…
Caffeinated nitric oxide-releasing lozenge improves cycling time trial performance.
Lee, J; Kim, H T; Solares, G J; Kim, K; Ding, Z; Ivy, J L
2015-02-01
Boosting nitric oxide production during exercise by various means has been found to improve exercise performance. We investigated the effects of a nitric oxide releasing lozenge with added caffeine (70 mg) on oxygen consumption during steady-state exercise and cycling time trial performance using a double-blinded randomized, crossover experimental design. 15 moderately trained cyclists (7 females and 8 males) were randomly assigned to ingest the caffeinated nitric oxide lozenge or placebo 5 min before exercise. Oxygen consumption and blood lactate were assessed at rest and at 50%, 65% and 75% maximal oxygen consumption. Exercise performance was assessed by time to complete a simulated 20.15 km cycling time-trial course. No significant treatment effects for oxygen consumption or blood lactate at rest or during steady-state exercise were observed. However, time-trial performance was improved by 2.1% (p<0.01) when participants consumed the nitric oxide lozenge (2,424±69 s) compared to placebo (2,476±78 s) and without a significant difference in rating of perceived exertion. These results suggest that acute supplementation with a caffeinated nitric oxide releasing lozenge may be a practical and effective means of improving aerobic exercise performance. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Yoshikawa, Choiku; Hattori, Kazuhiro; Jeong, Jongsoo; Saito, Kiyoshi; Kawai, Sunao
An ejector can transform the expansion energy of the driving flow into the pressure build-up energy of the suction flow. Therefore, by utilizing the ejector instead of the expansion valve for the vapor compression cycle, the performance of the cycle can be greatly improved. Until now, the performance of the vapor compression cycle with the ejector has not been examined sufficiently. Therefore, this paper constructs the simulation model of the vapor compression cycle with the ejector and investigates the performance of that cycle by the simulation. Working fluids are ammonia and CO2. As a result, in case of the ejector efficiency 90%, COP of the vapor compression cycle using ammonia with the ejector is 5% higher than that of the conventional cycle and COP using CO2 with the ejector is 22% higher than that of the conventional cycle.
Study of Lithium Silicide Nanoparticles as Anode Materials for Advanced Lithium Ion Batteries.
Li, Xuemin; Kersey-Bronec, Faith E; Ke, John; Cloud, Jacqueline E; Wang, Yonglong; Ngo, Chilan; Pylypenko, Svitlana; Yang, Yongan
2017-05-17
The development of high-performance silicon anodes for the next generation of lithium ion batteries (LIBs) evokes increasing interest in studying its lithiated counterpart-lithium silicide (Li x Si). In this paper we report a systematic study of three thermodynamically stable phases of Li x Si (x = 4.4, 3.75, and 2.33) plus nitride-protected Li 4.4 Si, which are synthesized via the high-energy ball-milling technique. All three Li x Si phases show improved performance over that of unmodified Si, where Li 4.4 Si demonstrates optimum performance with a discharging capacity of 3306 (mA h)/g initially and maintains above 2100 (mA h)/g for over 30 cycles and above 1200 (mA h)/g for over 60 cycles at the current density of 358 mA/g of Si. A fundamental question studied is whether different electrochemical paradigms, that is, delithiation first or lithiation first, influence the electrode performance. No significant difference in electrode performance is observed. When a nitride layer (Li x N y Si z ) is created on the surface of Li 4.4 Si, the cyclability is improved to retain the capacity above 1200 (mA h)/g for more than 80 cycles. By increasing the nitridation extent, the capacity retention is improved significantly from the average decrease of 1.06% per cycle to 0.15% per cycle, while the initial discharge capacity decreases due to the inactivity of Si in the Li x N y Si z layer. Moreover, the Coulombic efficiencies of all Li x Si-based electrodes in the first cycle are significantly higher than that of a Si electrode (∼90% vs 40-70%).
LIFE CYCLE DESIGN OF AMORPHOUS SILICON PHOTOVOLTAIC MODULES
The life cycle design framework was applied to photovoltaic module design. The primary objective of this project was to develop and evaluate design metrics for assessing and guiding the Improvement of PV product systems. Two metrics were used to assess life cycle energy perform...
Second law analysis of advanced power generation systems using variable temperature heat sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bliem, C.J.; Mines, G.L.
1990-01-01
Many systems produce power using variable temperature (sensible) heat sources. The Heat Cycle Research Program is currently investigating the potential improvements to such power cycles utilizing moderate temperature geothermal resources to produce electrical power. It has been shown that mixtures of saturated hydrocarbons (alkanes) or halogenated hydrocarbons operating with a supercritical Rankine cycle gave improved performance over boiling Rankine cycles with the pure working fluids for typical applications. Recently, in addition to the supercritical Rankine Cycle, other types of cycles have been proposed for binary geothermal service. This paper explores the limits on efficiency of a feasible plant and discussesmore » the methods used in these advanced concept plants to achieve the maximum possible efficiency. The advanced plants considered appear to be approaching the feasible limit of performance so that the designer must weigh all considerations to fine the best plant for a given service. These results would apply to power systems in other services as well as to geothermal power plants. 17 refs., 15 figs.« less
Sex differences in pacing during ‘Ultraman Hawaii’
Nikolaidis, Pantelis T.
2016-01-01
Background To date, little is known for pacing in ultra-endurance athletes competing in a non-stop event and in a multi-stage event, and especially, about pacing in a multi-stage event with different disciplines during the stages. Therefore, the aim of the present study was to examine the effect of age, sex and calendar year on triathlon performance and variation of performance by events (i.e., swimming, cycling 1, cycling 2 and running) in ‘Ultraman Hawaii’ held between 1983 and 2015. Methods Within each sex, participants were grouped in quartiles (i.e., Q1, Q2, Q3 and Q4) with Q1 being the fastest (i.e., lowest overall time) and Q4 the slowest (i.e., highest overall time). To compare performance among events (i.e., swimming, cycling 1, cycling 2 and running), race time in each event was converted in z score and this value was used for further analysis. Results A between-within subjects ANOVA showed a large sex × event (p = 0.015, η2 = 0.014) and a medium performance group × event interaction (p = 0.001, η2 = 0.012). No main effect of event on performance was observed (p = 0.174, η2 = 0.007). With regard to the sex × event interaction, three female performance groups (i.e., Q2, Q3 and Q4) increased race time from swimming to cycling 1, whereas only one male performance group (Q4) revealed a similar trend. From cycling 1 to cycling 2, the two slower female groups (Q3 and Q4) and the slowest male group (Q4) increased raced time. In women, the fastest group decreased (i.e., improved) race time from swimming to cycling 1 and thereafter, maintained performance, whereas in men, the fastest group decreased race time till cycling 2 and increased it in the running. Conclusion In summary, women pace differently than men during ‘Ultraman Hawaii’ where the fastest women decreased performance on day 1 and could then maintain on day 2 and 3, whereas the fastest men worsened performance on day 1 and 2 but improved on day 3. PMID:27703854
Sasada, Syusaku; Endoh, Takashi; Ishii, Tomoya; Komiyama, Tomoyoshi
2017-09-14
Sprint motor performance, such as in short-distance running or cycling, gradually decreases after reaching a maximum speed or cadence. This may be attributed to the central nervous system. Brain stimulation studies have recently revealed the plastic nature of the human brain and spinal cord, but it is unclear how direct current stimulation (DCS) affects sprint motor performance. To address this issue, we investigated DCS's effect on healthy volunteers' sprint cycling performance. DCS was applied to the lumbar spinal cord (3mA) or the leg area of the motor cortex (2mA) for 15min with 3 different polarities: anodal, cathodal, and sham. After DCS, the subjects performed maximal-effort sprint cycling for 30s under a constant load. Pooled mean power during the 30s was significantly greater after cathodal transcutaneous spinal DCS to the lumbar spinal cord (tsDCS) than anodal or sham tsDCS. The improvement with cathodal stimulation was notable both 0-5 and 20-25s after the performance onset. There were no significant inter-conditional differences in peak power. Pooled mean power was significantly greater after anodal transcranial DCS to the motor cortex (tDCS) than after cathodal tDCS, although mean powers of anodal and sham tDCS were not significantly different. The increase in mean power after cathodal tsDCS could result from a reduction in central fatigue. This stimulus method might improve sprint performance. Copyright © 2017 Elsevier B.V. All rights reserved.
High Energy, Long Cycle Life Lithium-ion Batteries for PHEV Application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Donghai; Manthiram, Arumugam; Wang, Chao-Yang
High-loading and high quality PSU Si anode has been optimized and fabricated. The electrochemical performance has been utilized. The PSU Si-graphite anode exhibits the mass loading of 5.8 mg/cm2, charge capacity of 850 mAh/ g and good cycling performance. This optimized electrode has been used for full-cell fabrication. The performance enhancement of Ni-rich materials can be achieved by a diversity of strategies. Higher Mn content and a small amount of Al doping can improve the electrochemical performance by suppressing interfacial side reactions with electrolytes, thus greatly benefiting the cyclability of the samples. Also, surface coatings of Li-rich materials and AlFmore » 3 are able to improve the performance stability of Ni-rich cathodes. One kilogram of optimized concentration-gradient LiNi 0.76Co 0.10Mn 0.14O 2 (CG) with careful control of composition, morphology and electrochemical performance was delivered to our collaborators. The sample achieved an initial specific capacity close to 190 mA h g -1 at C/10 rate and 180 mA h g -1 at C/3 rate as well as good cyclability in pouch full cells with a 4.4 V upper cut-off voltage at room temperature. Electrolyte additive with Si-N skeleton forms a less resistant SEI on the surface of silicon anode (from PSU) as evidenced by the evolution of the impedance at various lithiation/de-lithiation stages and the cycling data The prelithiation result demonstrates a solution processing method to achieve large area, uniform SLMP coating on well-made anode surface for the prelithiation of lithium-ion batteries. The prelithiation effect with this method is applied both in graphite half cells, graphite/NMC full cells, SiO half cells, SiO/NMC full cells, Si-Graphite half cells and Si-Graphite/NMC full cells with improvements in cycle performance and higher first cycle coulombic efficiency than their corresponding cells without SLMP prelithiation. As to the full cell fabrication and test, full pouch cells with high capacity of 2.2 Ah and 1.2 Ah have been fabricated and delivered. The cells show great uniformity and good cycling performance. The prelithiation method effectively compensate the loss in the first cycle. The cell with high energy density and long-cycle life has been achieved.« less
Improved performances of β-Ni(OH)2@reduced-graphene-oxide in Ni-MH and Li-ion batteries.
Li, Baojun; Cao, Huaqiang; Shao, Jin; Zheng, He; Lu, Yuexiang; Yin, Jiefu; Qu, Meizhen
2011-03-21
Incorporation of reduced graphene oxide into β-Ni(OH)(2) presents high performances with specific discharge capacity of 283 mA hg(-1) after 50 cycles in Ni-MH batteries, and 507 mA hg(-1) after 30 cycles in Li ion batteries.
Numerical Assessment of Four-Port Through-Flow Wave Rotor Cycles with Passage Height Variation
NASA Technical Reports Server (NTRS)
Paxson, D. E.; Lindau, Jules W.
1997-01-01
The potential for improved performance of wave rotor cycles through the use of passage height variation is examined. A Quasi-one-dimensional CFD code with experimentally validated loss models is used to determine the flowfield in the wave rotor passages. Results indicate that a carefully chosen passage height profile can produce substantial performance gains. Numerical performance data are presented for a specific profile, in a four-port, through-flow cycle design which yielded a computed 4.6% increase in design point pressure ratio over a comparably sized rotor with constant passage height. In a small gas turbine topping cycle application, this increased pressure ratio would reduce specific fuel consumption to 22% below the un-topped engine; a significant improvement over the already impressive 18% reductions predicted for the constant passage height rotor. The simulation code is briefly described. The method used to obtain rotor passage height profiles with enhanced performance is presented. Design and off-design results are shown using two different computational techniques. The paper concludes with some recommendations for further work.
Sundström Poromaa, Inger; Gingnell, Malin
2014-01-01
The menstrual cycle has attracted research interest ever since the 1930s. For many researchers the menstrual cycle is an excellent model of ovarian steroid influence on emotion, behavior, and cognition. Over the past years methodological improvements in menstrual cycle studies have been noted, and this review summarizes the findings of methodologically sound menstrual cycle studies in healthy women. Whereas the predominant hypotheses of the cognitive field state that sexually dimorphic cognitive skills that favor men are improved during menstrual cycle phases with low estrogen and that cognitive skills that favor women are improved during cycle phases with increased estrogen and/or progesterone, this review has not found sufficient evidence to support any of these hypotheses. Mental rotation has gained specific interest in this aspect, but a meta-analysis yielded a standardized mean difference in error rate of 1.61 (95% CI -0.35 to 3.57), suggesting, at present, no favor of an early follicular phase improvement in mental rotation performance. Besides the sexually dimorphic cognitive skills, studies exploring menstrual cycle effects on tasks that probe prefrontal cortex function, for instance verbal or spatial working memory, have also been reviewed. While studies thus far are few, results at hand suggest improved performance at times of high estradiol levels. Menstrual cycle studies on emotional processing, on the other hand, tap into the emotional disorders of the luteal phase, and may be of relevance for women with premenstrual disorders. Although evidence at present is limited, it is suggested that emotion recognition, consolidation of emotional memories, and fear extinction is modulated by the menstrual cycle in women. With the use of functional magnetic resonance imaging, several studies report changes in brain reactivity across the menstrual cycle, most notably increased amygdala reactivity in the luteal phase. Thus, to the extent that behavioral changes have been demonstrated over the course of the menstrual cycle, the best evidence suggests that differences in sexually dimorphic tasks are small and difficult to replicate. However, emotion-related changes are more consistently found, and are better associated with progesterone than with estradiol such that high progesterone levels are associated with increased amygdala reactivity and increased emotional memory.
Sundström Poromaa, Inger; Gingnell, Malin
2014-01-01
The menstrual cycle has attracted research interest ever since the 1930s. For many researchers the menstrual cycle is an excellent model of ovarian steroid influence on emotion, behavior, and cognition. Over the past years methodological improvements in menstrual cycle studies have been noted, and this review summarizes the findings of methodologically sound menstrual cycle studies in healthy women. Whereas the predominant hypotheses of the cognitive field state that sexually dimorphic cognitive skills that favor men are improved during menstrual cycle phases with low estrogen and that cognitive skills that favor women are improved during cycle phases with increased estrogen and/or progesterone, this review has not found sufficient evidence to support any of these hypotheses. Mental rotation has gained specific interest in this aspect, but a meta-analysis yielded a standardized mean difference in error rate of 1.61 (95% CI −0.35 to 3.57), suggesting, at present, no favor of an early follicular phase improvement in mental rotation performance. Besides the sexually dimorphic cognitive skills, studies exploring menstrual cycle effects on tasks that probe prefrontal cortex function, for instance verbal or spatial working memory, have also been reviewed. While studies thus far are few, results at hand suggest improved performance at times of high estradiol levels. Menstrual cycle studies on emotional processing, on the other hand, tap into the emotional disorders of the luteal phase, and may be of relevance for women with premenstrual disorders. Although evidence at present is limited, it is suggested that emotion recognition, consolidation of emotional memories, and fear extinction is modulated by the menstrual cycle in women. With the use of functional magnetic resonance imaging, several studies report changes in brain reactivity across the menstrual cycle, most notably increased amygdala reactivity in the luteal phase. Thus, to the extent that behavioral changes have been demonstrated over the course of the menstrual cycle, the best evidence suggests that differences in sexually dimorphic tasks are small and difficult to replicate. However, emotion-related changes are more consistently found, and are better associated with progesterone than with estradiol such that high progesterone levels are associated with increased amygdala reactivity and increased emotional memory. PMID:25505380
Effects of a Non-Circular Chainring on Sprint Performance During a Cycle Ergometer Test
Hintzy, Frédérique; Grappe, Frédéric; Belli, Alain
2016-01-01
Non-circular chainrings have been reported to alter the crank angular velocity profile over a pedal revolution so that more time is spent in the effective power phase. The purpose of this study was to determine whether sprint cycling performance could be improved using a non-circular chainring (Osymetric: ellipticity 1.25 and crank lever mounted nearly perpendicular to the major axis), in comparison with a circular chainring. Twenty sprint cyclists performed an 8 s sprint on a cycle ergometer against a 0.5 N/kg-1 friction force in four crossing conditions (non-circular or circular chainring with or without clipless pedal). Instantaneous force, velocity and power were continuously measured during each sprint. Three main characteristic pedal downstrokes were selected: maximal force (in the beginning of the sprint), maximal power (towards the middle), and maximal velocity (at the end of the sprint). Both average and instantaneous force, velocity and power were calculated during the three selected pedal downstrokes. The important finding of this study was that the maximal power output was significantly higher (+ 4.3%, p < 0.05) when using the non-circular chainring independent from the shoe-pedal linkage condition. This improvement is mainly explained by a significantly higher instantaneous external force that occurs during the downstroke. Non-circular chainring can have potential benefits on sprint cycling performance. Key points The Osymetric non-circular chainring significantly maximized crank power by 4.3% during sprint cycling, in comparison with a circular chainring. This maximal power output improvement was due to significant higher force developed when the crank was in the effective power phase. This maximal power output improvement was independent from the shoe-pedal linkage condition. Present benefits provided by the non-circular chainring on pedalling kinetics occurred only at high cadences. PMID:27274658
Williams, Emily L; Jones, Hollie S; Andy Sparks, S; Marchant, David C; Midgley, Adrian W; Mc Naughton, Lars R
2015-07-01
Whilst the presence of a competitor has been found to improve performance, the mechanisms influencing the change in selected work rates during direct competition have been suggested but not specifically assessed. The aim was to investigate the physiological and psychological influences of a visual avatar competitor during a 16.1-km cycling time trial performance, using trained, competitive cyclists. Randomised cross-over design. Fifteen male cyclists completed four 16.1km cycling time trials on a cycle ergometer, performing two with a visual display of themselves as a simulated avatar (FAM and SELF), one with no visual display (DO), and one with themselves and an opponent as simulated avatars (COMP). Participants were informed the competitive avatar was a similar ability cyclist but it was actually a representation of their fastest previous performance. Increased performance times were evident during COMP (27.8±2.0min) compared to SELF (28.7±1.9min) and DO (28.4±2.3min). Greater power output, speed and heart rate were apparent during COMP trial than SELF (p<0.05) and DO (p≤0.06). There were no differences between SELF and DO. Ratings of perceived exertion were unchanged across all conditions. Internal attentional focus was significantly reduced during COMP trial (p<0.05), suggesting reduced focused on internal sensations during an increase in performance. Competitive cyclists performed significantly faster during a 16.1-km competitive trial than when performing maximally, without a competitor. The improvement in performance was elicited due to a greater external distraction, deterring perceived exertion. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Vikmoen, Olav; Rønnestad, Bent R; Ellefsen, Stian; Raastad, Truls
2017-03-01
The purpose of this study was to investigate the effects of adding heavy strength training to female duathletes' normal endurance training on both cycling and running performance. Nineteen well-trained female duathletes ( V O 2max cycling: 54 ± 3 ml∙kg -1 ∙min -1 , VO 2max running: 53 ± 3 ml∙kg -1 ∙min -1 ) were randomly assigned to either normal endurance training ( E , n = 8) or normal endurance training combined with strength training ( E+S , n = 11). The strength training consisted of four lower body exercises [3 × 4-10 repetition maximum (RM)] twice a week for 11 weeks. Running and cycling performance were assessed using 5-min all-out tests, performed immediately after prolonged periods of submaximal work (3 h cycling or 1.5 h running). E+S increased 1RM in half squat (45 ± 22%) and lean mass in the legs (3.1 ± 4.0%) more than E Performance during the 5-min all-out test increased in both cycling (7.0 ± 4.5%) and running (4.7 ± 6.0%) in E+S, whereas no changes occurred in E The changes in running performance were different between groups. E+S reduced oxygen consumption and heart rate during the final 2 h of prolonged cycling, whereas no changes occurred in E No changes occurred during the prolonged running in any group. Adding strength training to normal endurance training in well-trained female duathletes improved both running and cycling performance when tested immediately after prolonged submaximal work. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Jayasinha, Yasangi
2016-01-01
Increasingly, health care quality indicators are focusing on patient-centeredness as an indicator of performance. The National Quality Forum lists assessment of patient experience, often conducted using patient surveys, as a top priority. We developed a patient-reported time stamp data collection tool that was used to collect cycle times in a safety net hospital-based outpatient pediatrics clinic. Data were collected using patient-reported survey to obtain cycle times in Pediatric clinic, as well as qualitative and quantitative patient satisfaction data. Several rapid-cycle improvements were performed using Lean Six Sigma methodologies to reduce cycle time by eliminating waste and revise unnecessary processes to improve operational effectiveness and patient and staff satisfaction. A total of 94 surveys were collected and revealed average cycle time of 113 minutes. Our measured patient satisfaction rating was 87%. Discharge and check-in processes were identified as the least efficient and were targeted for intervention. Following implementation, the overall cycle time was decreased from 113 to 90 minutes. Patient satisfaction ratings increased from 87% to 95%. We demonstrate that using Lean Six Sigma tools can be invaluable to clinical restructuring and redesign and results in measurable, improved outcomes in care delivery.
Effect of contrast water therapy duration on recovery of cycling performance: a dose-response study.
Versey, Nathan; Halson, Shona; Dawson, Brian
2011-01-01
This study investigated whether contrast water therapy (CWT) has a dose-response effect on recovery from high-intensity cycling. Eleven trained male cyclists completed four trials, each commencing with a 75-min cycling protocol containing six sets of five 15-s sprints and three 5-min time-trials in thermoneutral conditions. Ten minutes post-exercise, participants performed one of four recovery protocols: CWT for 6 min (CWT6), 12 min (CWT12), or 18 min (CWT18) duration, or a seated rest control trial. The CWT commenced in hot water (38.4 ± 0.6°C) and alternated between hot and cold water (14.6 ± 0.3°C) every minute with a 5-s changeover. The cycling protocol was repeated 2 h after completion of exercise bout one. Prior to exercise bout two, core temperature was lower in CWT12 (-0.19 ± 0.14°C, mean ± 90% CL) and CWT18 (-0.21 ± 0.10°C) than control. Compared with control, CWT6 substantially improved time-trial (1.5 ± 2.1%) and sprint performance (3.0 ± 3.1%), and CWT12 substantially improved sprint total work (4.3 ± 3.4%) and peak power (2.7 ± 3.8%) in exercise bout two. All CWT conditions generally improved thermal sensation, whole body fatigue and muscle soreness compared with control, but no differences existed between conditions in heart rate or rating of perceived exertion. In conclusion, CWT duration did not have a dose-response effect on recovery from high-intensity cycling; however, CWT for up to 12 min assisted recovery of cycling performance.
NASA Technical Reports Server (NTRS)
Levine, S. R.; Grisaffe, S. J.
1972-01-01
Edge and surface modification of niobium alloys prior to coating with Si-20Cr-20Fe and slurry composition modification were investigated to improve performance in a 1370 C, ambient pressure, slow-cycle test. The best coating obtained was Si-20Cr-20Mn with an average life of 63 cycles compared to 40 for Si-20Cr-20Fe on FS-85 (100 percent improvement in weight parity life). Edge beading extended the lives of Si-20Cr-20Fe coated Cb-752 and FS-85 to 57 and 41 cycles, respectively (50 and 20 percent improvements in weight parity life, respectively).
Subsonic Performance of Ejector Systems
NASA Astrophysics Data System (ADS)
Weil, Samuel
Combined cycle engines combining scramjets with turbo jets or rockets can provide efficient hypersonic flight. Ejectors have the potential to increase the thrust and efficiency of combined cycle engines near static conditions. A computer code was developed to support the design of a small-scale, turbine-based combined cycle demonstrator with an ejector, built around a commercially available turbojet engine. This code was used to analyze the performance of an ejector system built around a micro-turbojet. With the use of a simple ejector, net thrust increases as large as 20% over the base engine were predicted. Additionally the specific fuel consumption was lowered by 10%. Increasing the secondary to primary area ratio of the ejector lead to significant improvements in static thrust, specific fuel consumption (SFC), and propulsive efficiency. Further ejector performance improvements can be achieved by using a diffuser. Ejector performance drops off rapidly with increasing Mach number. The ejector has lower thrust and higher SFC than the turbojet core at Mach numbers above 0.2. When the nozzle chokes a significant drop in ejector performance is seen. When a diffuser is used, higher Mach numbers lead to choking in the mixer and a shock in the nozzle causing a significant decrease in ejector performance. Evaluation of different turbo jets shows that ejector performance depends significantly on the properties of the turbojet. Static thrust and SFC improvements can be achieved with increasing ejector area for all engines, but size of increase and change in performance at higher Mach numbers depend heavily on the turbojet. The use of an ejector in a turbine based combined cycle configuration also increases performance at static conditions with a thrust increase of 5% and SFC decrease of 5% for the tested configuration.
Variable mixture ratio performance through nitrogen augmentation
NASA Technical Reports Server (NTRS)
Beichel, R.; Obrien, C. J.; Bair, E. K.
1988-01-01
High/variable mixture ratio O2/H2 candidate engine cycles are examined for earth-to-orbit vehicle application. Engine performance and power balance information are presented for the candidate cycles relative to chamber pressure, bulk density, and mixture ratio. Included in the cycle screening are concepts where a third fluid (liquid nitrogen) is used to achieve a variable mixture ratio over the trajectory from liftoff to earth orbit. The third fluid cycles offer a very low risk, fully reusable, low operation cost alternative to high/variable mixture ratio bipropellant cycles. Variable mixture ratio engines with extendible nozzle are slightly lower performing than a single mixture ratio engine (MR = 7:1) with extendible nozzle. Dual expander engines (MR = 7:1) have slightly better performance than the single mixture ratio engine. Dual fuel dual expander engines offer a 16 percent improvement over the single mixture ratio engine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, S., E-mail: sankha.deepp@gmail.com; Mondal, P., E-mail: mondal.pradip87@gmail.com; Ghosh, S., E-mail: sudipghosh.becollege@gmail.com
Rapid depletion of fossil fuel has forced mankind to look into alternative fuel resources. In this context, biomass based power generation employing gas turbine appears to be a popular choice. Bio-gasification based combined cycle provides a feasible solution as far as grid-independent power generation is concerned for rural electrification projects. Indirectly heated gas turbine cycles are promising alternatives as they avoid downstream gas cleaning systems. Advanced thermodynamic cycles have become an interesting area of study to improve plant efficiency. Water injected system is one of the most attractive options in this field of applications. This paper presents a theoretical modelmore » of a biomass gasification based combined cycle that employs an indirectly heated humid air turbine (HAT) in the topping cycle. Maximum overall electrical efficiency is found to be around 41%. Gas turbine specific air consumption by mass is minimum when pressure ratio is 6. The study reveals that, incorporation of the humidification process helps to improve the overall performance of the plant.« less
Experimental research made during a city cycle on the feasibility of electrically charged SI engines
NASA Astrophysics Data System (ADS)
Kocsis, Levente B.; Burnete, Nicolae
2014-06-01
The paper presents experimental research on performance improvements in a city cycle (operating mostly transient) of a compact class vehicle equipped with a turbocharged SI engine which had attached an electric charger, to improve engine response at low operational speeds. During tests, functional parameters, energy consumption of the electric charger and vehicle performances were measured while driving in two operating conditions: with active and inactive electric charger. The tests were carried out on a well-defined path, in the same driving style, by the same driver.
Oh, Hong-Choon; Toh, Hong-Guan; Giap Cheong, Eddy Seng
2011-11-01
Using the classical process improvement framework of Plan-Do-Study-Act (PDSA), the diagnostic radiology department of a tertiary hospital identified several patient cycle time reduction strategies. Experimentation of these strategies (which included procurement of new machines, hiring of new staff, redesign of queue system, etc.) through pilot scale implementation was impractical because it might incur substantial expenditure or be operationally disruptive. With this in mind, simulation modeling was used to test these strategies via performance of "what if" analyses. Using the output generated by the simulation model, the team was able to identify a cost-free cycle time reduction strategy, which subsequently led to a reduction of patient cycle time and achievement of a management-defined performance target. As healthcare professionals work continually to improve healthcare operational efficiency in response to rising healthcare costs and patient expectation, simulation modeling offers an effective scientific framework that can complement established process improvement framework like PDSA to realize healthcare process enhancement. © 2011 National Association for Healthcare Quality.
2013-01-01
Background We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. Methods Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek’s p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps ′guideline – perform - falsify – reform′. Results 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. Conclusions The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity. PMID:24074151
Analytical investigation of thermal barrier coatings on advanced power generation gas turbines
NASA Technical Reports Server (NTRS)
Amos, D. J.
1977-01-01
An analytical investigation of present and advanced gas turbine power generation cycles incorporating thermal barrier turbine component coatings was performed. Approximately 50 parametric points considering simple, recuperated, and combined cycles (including gasification) with gas turbine inlet temperatures from current levels through 1644K (2500 F) were evaluated. The results indicated that thermal barriers would be an attractive means to improve performance and reduce cost of electricity for these cycles. A recommended thermal barrier development program has been defined.
A Study of Waste-Heat-Boiler Size and Performance of a Conceptual Marine COGAS System.
1980-02-01
The addition of a waste-heat boiler which extracts heat from the gas turbine exhaust gas to operate a bottoming Rankine cycle is one way to improve the...do not change significantly. Higher saturation pressure actually results in a somewhat lower boiler heat transfer, but the Rankine - cycle performance...of heat transferred in the waste-heat boiler and (2) the conversion efficiency of the Rankine cycle . In sizing the waste-heat boiler, attention was
Fowler, Eileen G; Knutson, Loretta M; Demuth, Sharon K; Siebert, Kara L; Simms, Victoria D; Sugi, Mia H; Souza, Richard B; Karim, Roksana; Azen, Stanley P
2010-03-01
Effective interventions to improve and maintain strength (force-generating capacity) and endurance are needed for children with cerebral palsy (CP). This study was performed to examine the effects of a stationary cycling intervention on muscle strength, locomotor endurance, preferred walking speed, and gross motor function in children with spastic diplegic CP. This was a phase I randomized controlled trial with single blinding. The interventions were performed in community-based outpatient physical therapy clinics. Outcome assessments were performed in university laboratories. Sixty-two ambulatory children aged 7 to 18 years with spastic diplegic CP and Gross Motor Function Classification System levels I to III participated in this study. Participants were randomly assigned to cycling or control (no-intervention) groups. Thirty intervention sessions occurred over 12 weeks. Primary outcomes were peak knee extensor and flexor moments, the 600-Yard Walk-Run Test, the Thirty-Second Walk Test, and the Gross Motor Function Measure sections D and E (GMFM-66). Significant baseline-postintervention improvements were found for the 600-Yard Walk-Run Test, the GMFM-66, peak knee extensor moments at 120 degrees /s, and peak knee flexor moments at 30 degrees /s for the cycling group. Improved peak knee flexor moments at 120 degrees/s were found for the control group only, although not all participants could complete this speed of testing. Significant differences between the cycling and control groups based on change scores were not found for any outcomes. Limitations Heterogeneity of the patient population and intrasubject variability were limitations of the study. Significant improvements in locomotor endurance, gross motor function, and some measures of strength were found for the cycling group but not the control group, providing preliminary support for this intervention. As statistical differences were not found in baseline-postintervention change scores between the 2 groups; the results did not demonstrate that stationary cycling was more effective than no intervention. The results of this phase I study provide guidance for future research.
The energetics of cycling on Earth, Moon and Mars.
Lazzer, Stefano; Plaino, Luca; Antonutto, Guglielmo
2011-03-01
From 1885, technological improvements, such as the use of special metal alloys and the application of aerodynamics principles, have transformed the bicycle from a human powered heavy transport system to an efficient, often expensive, object used to move not only in our crowded cities, but also in leisure activities and in sports. In this paper, the concepts of mechanical work and efficiency of cycling together with the corresponding metabolic expenditure are discussed. The effects of altitude and aerodynamic improvements on sports performances are also analysed. A section is dedicated to the analysis of the maximal cycling performances. Finally, since during the next decades the return of Man on the Moon and, why not, a mission to Mars can be realistically hypothesised, a section is dedicated to cycling-based facilities, such as man powered short radius centrifuges, to be used to prevent cardiovascular and skeletal muscle deconditioning otherwise occurring during long-term exposure to microgravity.
The effects of short-cycle sprints on power, strength, and salivary hormones in elite rugby players.
Crewther, Blair T; Cook, Christian J; Lowe, Tim E; Weatherby, Robert P; Gill, Nicholas
2011-01-01
This study examined the effects of short-cycle sprints on power, strength, and salivary hormones in elite rugby players. Thirty male rugby players performed an upper-body power and lower-body strength (UPLS) and/or a lower-body power and upper-body strength (LPUS) workout using a crossover design (sprint vs. control). A 40-second upper-body or lower-body cycle sprint was performed before the UPLS and LPUS workouts, respectively, with the control sessions performed without the sprints. Bench throw (BT) power and box squat (BS) 1 repetition maximum (1RM) strength were assessed in the UPLS workout, and squat jump (SJ) power and bench press (BP) 1RM strength were assessed in the LPUS workout. Saliva was collected across each workout and assayed for testosterone (Sal-T) and cortisol (Sal-C). The cycle sprints improved BS (2.6 ± 1.2%) and BP (2.8 ± 1.0%) 1RM but did not affect BT and SJ power. The lower-body cycle sprint produced a favorable environment for the BS by elevating Sal-T concentrations. The upper-body cycle sprint had no hormonal effect, but the workout differences (%) in Sal-T (r = -0.59) and Sal-C (r = 0.42) concentrations correlated to the BP, along with the Sal-T/C ratio (r = -0.49 to -0.66). In conclusion, the cycle sprints improved the BP and BS 1RM strength of elite rugby players but not power output in the current format. The improvements noted may be explained, in part, by the changes in absolute or relative hormone concentrations. These findings have practical implications for prescribing warm-up and training exercises.
Visco, Steven J.; Nimon, Yevgeniy S.; De Jonghe, Lutgard C.; Petrov, Alexei; Goncharenko, Nikolay
2017-05-23
Aqueous Li/Air secondary battery cells are configurable to achieve high energy density and prolonged cycle life. The cells include a protected a lithium metal or alloy anode and an aqueous catholyte in a cathode compartment. The aqueous catholyte comprises an evaporative-loss resistant and/or polyprotic active compound or active agent that partakes in the discharge reaction and effectuates cathode capacity for discharge in the acidic region. This leads to improved performance including one or more of increased specific energy, improved stability on open circuit, and prolonged cycle life, as well as various methods, including a method of operating an aqueous Li/Air cell to simultaneously achieve improved energy density and prolonged cycle life.
Plasma-assisted nitrogen doping of VACNTs for efficiently enhancing the supercapacitor performance
NASA Astrophysics Data System (ADS)
Mashayekhi, Alireza; Hosseini, Seyed Mahmoud; Hassanpour Amiri, Morteza; Namdar, Naser; Sanaee, Zeinab
2016-06-01
Nitrogen doping of vertically aligned carbon nanotubes (VACNTs) using plasma-enhanced chemical vapour deposition has been investigated to improve the supercapacitance performance of CNTs. Incorporating electrochemical measurements on the open-ended nitrogen-doped CNTs, showed the achievement of 6 times improvement in the capacitance value. For nitrogen-doped CNTs on silicon substrate, specific capacitance of 60 F g-1 was obtained in 0.5 M KCl solution, with capacity retention ratio above 90 % after cycled at 0.1 A g-1 for 5000 cycles. Using this sample, a symmetric supercapacitance was fabricated which showed the power density of 37.5 kW kg-1. The facile fabrication approach and its excellent capacitance improvement, propose it as an efficient technique for enhancing the supercapacitance performance of the carbon-based electrodes.
Babu, Dasari Bosu; Giribabu, Krishnan; Ramesha, Kannadka
2018-06-13
Minimizing the shuttle effect by constraining polysulfides to the cathode compartment and activating the passive layer between cathode and separator are highly important for improving the Li-S cell performance, Coulombic efficiency, and cycle life. Here, we report a submicron thin coating of permselective sulfonated poly(ether ether ketone) (SPEEK) composite layer on the separator that would reduce polysulfide crossover, imparting a significant improvement in cycle life. It is observed that SPEEK increases the stability, and adding Nafion improves the capacity value. Among different ratios of Nafion and SPEEK (25:75, 50:50, and 75:25), the composite with a SPEEK/Nafion ratio of 50:50 showed a controlled shuttle effect with a stable cell capacity of 600 mA h g -1 up to 300 cycles. This modified separator with permselective coatings not only reduces the polysulfide shuttle but also improves the wettability and interfacial contact, which results in an improvement in average cell potential and lithium diffusivity. It is demonstrated here that the combination of functional (ionomer coating on separator) and nonfunctional (extra cathode layer) physical barriers effectively suppresses the polysulfide crossover and improves the electrochemical performance of Li-S batteries. The cell shows an initial capacity of 1300 mA h g -1 and a capacity retention of 650 mA h g -1 over 500 cycles with a 6 mg/cm 2 sulfur loading.
Li, Na; Huang, Xuankai; Zhang, Haiyan; Li, Yunyong; Wang, Chengxin
2017-03-22
Improving mass loading while maintaining high transparency and large surface area in one self-supporting graphene film is still a challenge. Unfortunately, all of these factors are absolutely essential for enhancing the energy storage performance of transparent supercapacitors for practical applications. To solve the above bottleneck problem, we produce a novel self-supporting flexible and transparent graphene film (STF-GF) with wrinkled-wall-assembled opened-hollow polyhedron building units. Taking advantage of the microscopic morphology, the STF-GF exhibits improved mass loading with high transmittance (70.2% at 550 nm), a large surface area (1105.6 m 2 /g), and good electrochemical performance: high energy (552.3 μWh/cm 3 ), power densities (561.9 mW/cm 3 ), a superlong cycle life, and good cycling stability (the capacitance retention is ∼94.8% after 20,000 cycles).
Lithium/disulfide battery R and D
NASA Astrophysics Data System (ADS)
Kaun, T. D.; Deluca, W.; Lee, J.; Redey, L.; Nelson, P. A.
The focus of molten-salt cell R and D in the past year at Argonne National Laboratory has been on developing an understanding of the excellent performance and stability of a lithium/disulfide cell using LiCl-LiBr-KBr electrolyte. For further improvement, we have initiated development of a rod-electrode cell design and design of cells which can tolerate overdischarge and overcharge abuse. Earlier Li/FeS2 cells offered performance quite below expectations and had high capacity decline rates: 0.10 to 0.25 percent per cycle. Approaches for reducing the capacity decline rates of the earlier cells also reduced cell performance. However, our improved Li/FeS2 cell tests indicate good prospects for attaining cell development goals of specific energy of 200 Wh/kg at a 4-h discharge rate, a specific power of 200 W/kg at 80 percent depth of discharge, and a cycle life of 1000 cycles.
Wei, Xiaoliang; Xu, Wu; Huang, Jinhua; Zhang, Lu; Walter, Eric; Lawrence, Chad; Vijayakumar, M; Henderson, Wesley A; Liu, Tianbiao; Cosimbescu, Lelia; Li, Bin; Sprenkle, Vincent; Wang, Wei
2015-07-20
Nonaqueous redox flow batteries hold the promise of achieving higher energy density because of the broader voltage window than aqueous systems, but their current performance is limited by low redox material concentration, cell efficiency, cycling stability, and current density. We report a new nonaqueous all-organic flow battery based on high concentrations of redox materials, which shows significant, comprehensive improvement in flow battery performance. A mechanistic electron spin resonance study reveals that the choice of supporting electrolytes greatly affects the chemical stability of the charged radical species especially the negative side radical anion, which dominates the cycling stability of these flow cells. This finding not only increases our fundamental understanding of performance degradation in flow batteries using radical-based redox species, but also offers insights toward rational electrolyte optimization for improving the cycling stability of these flow batteries. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bourdillon, Nicolas; Fan, Jui-Lin; Uva, Barbara; Müller, Hajo; Meyer, Philippe; Kayser, Bengt
2015-01-01
Background: Hypoxia-induced pulmonary vasoconstriction increases pulmonary arterial pressure (PAP) and may impede right heart function and exercise performance. This study examined the effects of oral nitrate supplementation on right heart function and performance during exercise in normoxia and hypoxia. We tested the hypothesis that nitrate supplementation would attenuate the increase in PAP at rest and during exercise in hypoxia, thereby improving exercise performance. Methods: Twelve trained male cyclists [age: 31 ± 7 year (mean ± SD)] performed 15 km time-trial cycling (TT) and steady-state submaximal cycling (50, 100, and 150 W) in normoxia and hypoxia (11% inspired O2) following 3-day oral supplementation with either placebo or sodium nitrate (0.1 mmol/kg/day). We measured TT time-to-completion, muscle tissue oxygenation during TT and systolic right ventricle to right atrium pressure gradient (RV-RA gradient: index of PAP) during steady state cycling. Results: During steady state exercise, hypoxia elevated RV-RA gradient (p > 0.05), while oral nitrate supplementation did not alter RV-RA gradient (p > 0.05). During 15 km TT, hypoxia lowered muscle tissue oxygenation (p < 0.05). Nitrate supplementation further decreased muscle tissue oxygenation during 15 km TT in hypoxia (p < 0.05). Hypoxia impaired time-to-completion during TT (p < 0.05), while no improvements were observed with nitrate supplementation in normoxia or hypoxia (p > 0.05). Conclusion: Our findings indicate that oral nitrate supplementation does not attenuate acute hypoxic pulmonary vasoconstriction nor improve performance during time trial cycling in normoxia and hypoxia. PMID:26528189
Status of nickel/zinc and nickel/iron battery technology for electric vehicle applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, N.P.; Christianson, C.C.; Elliott, R.C.
1980-01-01
Significant progress in nickel/zinc and nickel/iron technology has been made towards achieving the battery technical performance goals necessary for widespread use of these battery systems in electric vehicle applications. This progress is reviewed. Nickel/zinc module test data have shown a specific energy of nearly 70 Whr/kg and a specific power of 130 W/kg. However, cycle life improvements are still needed (presently demonstrated capability of 120 cycles) and are expected to be demonstrated during 1980. Nickel/iron modules have demonstrated a specific energy of nearly 50 Wh/kg and a specific power of 100 W/kg. Indications are that improved performance in these areasmore » can be shown during 1980. Nickel/iron modules cycle lives of 300 have been achieved during early 1980 and testing continues. Energy efficiency has been improved from less than 50% to over 65%. Cost reduction (both initial and operating) continues to receive major emphasis at developers of both nickel/zinc and nickel/iron batteries in order to achieve the lowest possible life cycle cost to the battery user.« less
Interval Running Training Improves Cognitive Flexibility and Aerobic Power of Young Healthy Adults.
Venckunas, Tomas; Snieckus, Audrius; Trinkunas, Eugenijus; Baranauskiene, Neringa; Solianik, Rima; Juodsnukis, Antanas; Streckis, Vytautas; Kamandulis, Sigitas
2016-08-01
Venckunas, T, Snieckus, A, Trinkunas, E, Baranauskiene, N, Solianik, R, Juodsnukis, A, Streckis, V, and Kamandulis, S. Interval running training improves cognitive flexibility and aerobic power of young healthy adults. J Strength Cond Res 30(8): 2114-2121, 2016-The benefits of regular physical exercise may well extend beyond the reduction of chronic diseases risk and augmentation of working capacity, to many other aspects of human well-being, including improved cognitive functioning. Although the effects of moderate intensity continuous training on cognitive performance are relatively well studied, the benefits of interval training have not been investigated in this respect so far. The aim of the current study was to assess whether 7 weeks of interval running training is effective at improving both aerobic fitness and cognitive performance. For this purpose, 8 young dinghy sailors (6 boys and 2 girls) completed the interval running program with 200 m and 2,000 m running performance, cycling maximal oxygen uptake, and cognitive function was measured before and after the intervention. The control group consisted of healthy age-matched subjects (8 boys and 2 girls) who continued their active lifestyle and were tested in the same way as the experimental group, but did not complete any regular training. In the experimental group, 200 m and 2,000 m running performance and cycling maximal oxygen uptake increased together with improved results on cognitive flexibility tasks. No changes in the results of short-term and working memory tasks were observed in the experimental group, and no changes in any of the measured indices were evident in the controls. In conclusion, 7 weeks of interval running training improved running performance and cycling aerobic power, and were sufficient to improve the ability to adjust behavior to changing demands in young active individuals.
Maclaren, D P M; Mohebbi, H; Nirmalan, M; Keegan, M A; Best, C T; Perera, D; Harvie, M N; Campbell, I T
2011-09-01
Carbohydrate stores within muscle are considered essential as a fuel for prolonged endurance exercise, and regimes for enhancing such stores have proved successful in aiding performance. This study explored the effects of a hyperglycaemic-hyperinsulinemic clamp performed 18 h previously on subsequent prolonged endurance performance in cycling. Seven male subjects, accustomed to prolonged endurance cycling, performed 90 min of cycling at ~65% VO(2max) followed by a 16-km time trial 18 h after a 2-h hyperglycemic-hyperinsulinemic clamp (HCC). Hyperglycemia (10 mM) with insulin infused at 300 mU/m(2)/min over a 2-h period resulted in a total glucose uptake of 275 g (assessed by the area under the curve) of which glucose storage accounted for about 73% (i.e. 198 g). Patterns of substrate oxidation during 90-min exercise at 65% VO(2max) were not altered by HCC. Blood glucose and plasma insulin concentrations were higher during exercise after HCC compared with control (p < 0.05) while plasma NEFA was similar. Exercise performance was improved by 49 s and power output was 10-11% higher during the time trial (p < 0.05) after HCC. These data suggest that carbohydrate loading 18 h previously by means of a 2-h HCC improves cycling performance by 3.3% without any change in pattern of substrate oxidation.
NASA Astrophysics Data System (ADS)
Zhang, Deyi; Han, Mei; Wang, Bing; Li, Yubing; Lei, Longyan; Wang, Kunjie; Wang, Yi; Zhang, Liang; Feng, Huixia
2017-08-01
Vastly improving the charge storage capability of supercapacitors without sacrificing their high power density and cycle performance would bring bright application prospect. Herein, we report a nitrogen and sulfur co-doped hierarchical porous carbon (NSHPC) with very superior capacitance performance fabricated by KOH activation of nitrogen and sulfur co-doped ordered mesoporous carbon (NSOMC). A high electrochemical double-layer (EDL) capacitance of 351 F g-1 was observed for the reported NSHPC electrodes, and the capacitance remains at 288 F g-1 even under a large current density of 20 A g-1. Besides the high specific capacitance and outstanding rate capability, symmetrical supercapacitor cell based on the NSHPC electrodes also exhibits an excellent cycling performance with 95.61% capacitance retention after 5000 times charge/discharge cycles. The large surface area caused by KOH activation (2056 m2 g-1) and high utilized surface area owing to the ideal micro/mesopores ratio (2.88), large micropores diameter (1.38 nm) and short opened micropores structure as well as the enhanced surface wettability induced by N and S heteroatoms doping and improved conductivity induced by KOH activation was found to be responsible for the very superior capacitance performance.
Alkyl Pyrocarbonate Electrolyte Additives for Performance Enhancement of Li Ion Cells
NASA Technical Reports Server (NTRS)
Smart, M. C.; Ratnakumar, B. V.; Surampudi, S.
2000-01-01
Lithium ion rechargeable batteries are being developed for various aerospace applications under a NASA-DoD Interagency program. These applications require further improvements in several areas, specifically in the cycle life for LEO and GEO satellites and in the low temperature performance for the Mars Lander and Rover missions. Accordingly, we have been pursuing research studies to achieve improvement in the low temperature performance, long cycle life and active life of Li ion cells. The studies are mainly focused on electrolytes, to identify newer formulations of new electrolyte additives to enhance Li permeability (at low temperatures) and stability towards the electrode. The latter approach is particularly aimed at the formation suitable SEI (solid electrolyte interphase) on carbon electrodes. In this paper, we report the beneficial effect of using alkyl pyrocarbonates as electrolyte additives to improve the low temperature performance of Li ion cells.
Mullane, Sarah L; Buman, Matthew P; Zeigler, Zachary S; Crespo, Noe C; Gaesser, Glenn A
2017-05-01
To compare acute cognitive effects following bouts of standing (STAND), cycling (CYCLE) and walking (WALK) to a sit-only (SIT) condition. Randomized cross-over full-factorial study. Nine overweight (BMI=29±3kg/m 2 ) adults (30±15years; 7 females, 2 males) completed four conditions (SIT, STAND, WALK and CYCLE) across a 6h period with a 7days washout period between conditions. SIT consisted of uninterrupted sitting. Experimental conditions included intermittent bouts of standing (STAND), cycling (CYCLE) and walking (WALK). A cognitive performance battery (Cogstate) was completed twice in a seated position following bouts of standing and light-intensity physical activity. Mixed-effects models compared between-condition differences in standardized score (z-score), accuracy (%), and speed (log10ms). Cognitive performance z-score and accuracy measures were higher during STAND, CYCLE and WALK (P<0.05) conditions compared to the SIT condition. CYCLE was better than other experimental conditions. Compared to uninterrupted sitting, short bouts of standing or light-intensity cycling and walking may improve acute cognitive performance. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Carrillo, Alfonso J; Serrano, David P; Pizarro, Patricia; Coronado, Juan M
2015-06-08
Redox cycles of manganese oxides (Mn2 O3 /Mn3 O4 ) are a promising alternative for thermochemical heat storage systems coupled to concentrated solar power plants as manganese oxides are abundant and inexpensive materials. Although their cyclability for such a purpose has been proved, sintering processes, related to the high-temperature conditions at which charge-discharge cycles are performed, generally cause a cycle-to-cycle decrease in the oxidation rate of Mn3 O4 . To guarantee proper operation, both reactions should present stable reaction rates. In this study, it has been demonstrated that the incorporation of Fe, which is also an abundant material, into the manganese oxides improves the redox performance of this system by increasing the heat storage density, narrowing the redox thermal hysteresis, and, above all, stabilizing and enhancing the oxidation rate over long-term operation, which counteracts the negative effects caused by sintering, although its presence is not avoided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nijhuis-van der Sanden, Maria W G; Driehuis, Femke; Heerkens, Yvonne F; van der Vleuten, Cees P M; van der Wees, Philip J
2017-01-01
Objectives To evaluate the feasibility of a quality improvement programme aimed to enhance the client-centeredness, effectiveness and transparency of physiotherapy services by addressing three feasibility domains: (1) acceptability of the programme design, (2) appropriateness of the implementation strategy and (3) impact on quality improvement. Design Mixed methods study. Participants and setting 64 physiotherapists working in primary care, organised in a network of communities of practice in the Netherlands. Methods The programme contained: (1) two cycles of online self-assessment and peer assessment (PA) of clinical performance using client records and video-recordings of client communication followed by face-to-face group discussions, and (2) clinical audit assessing organisational performance. Assessment was based on predefined performance indicators which could be scored on a 5-point Likert scale. Discussions addressed performance standards and scoring differences. All feasibility domains were evaluated qualitatively with two focus groups and 10 in-depth interviews. In addition, we evaluated the impact on quality improvement quantitatively by comparing self-assessment and PA scores in cycles 1 and 2. Results We identified critical success features relevant to programme development and implementation, such as clarifying expectations at baseline, training in PA skills, prolonged engagement with video-assessment and competent group coaches. Self-reported impact on quality improvement included awareness of clinical and organisational performance, improved evidence-based practice and client-centeredness and increased motivation to self-direct quality improvement. Differences between self-scores and peer scores on performance indicators were not significant. Between cycles 1 and 2, scores for record keeping showed significant improvement, however not for client communication. Conclusions This study demonstrated that bottom-up initiatives to improve healthcare quality can be effective. The results justify ongoing evaluation to inform nationwide implementation when the critical success features are addressed. Further research is necessary to explore the sustainability of the results and the impact on client outcomes in a full-scale study. PMID:28188156
Chen, Jie; Xu, Mao-Wen; Wu, Jinggao; Li, Chang Ming
2018-05-17
Iodine edge-doped graphene can improve the capacity and stability of lithium-ion batteries (LIBs). Our theoretical calculations indicate that center-iodization can further significantly enhance the anode catalytic process. To experimentally prove the theoretical prediction, iodine-doped graphene materials were prepared by one-pot hydrothermal and ball-milling approaches to realize different doping-sites. Results show that the center-iodinated graphene (CIG) anode exhibits a remarkably high reversible capacity (1121 mA h g-1 after 180 cycles at 0.5 A g-1), long-cycle life (0.01% decay per cycle over 300 cycles at 1 A g-1) and high-rate capacity (374 mA h g-1 after 800 cycles at 8 A g-1), which greatly improves the performance of the edge-iodinated graphene anode and these results are in good agreement with the theoretical analysis. More importantly, the CIG anode also delivers a high-rate capacity and excellent cycling stability (279 mA h g-1 after 500 cycles at 10 A g-1) in full-cells. Both the theoretical analysis and experimental investigation reveal the enhancement mechanism, in which the center-iodization increases the surface charge for fast electron transfer rate, improves the conductivity for charge transport and rationalizes the pore structure for enhanced mass transport and ion insertion/desertion, thus resulting in a high rate capacity and long cycle life. This work not only discloses the critical role of catalytic sites including both amounts and site positions but also offers great potential for high-power rechargeable LIB applications.
DOT National Transportation Integrated Search
2017-08-31
This study seeks to improve the methodology for determining the relationship between cycling dynamic performance and roadway environment characteristics across different bicyclists' skill levels. To achieve the goal of this study, an Instrumented Pro...
Advanced oxygen-hydrocarbon rocket engine study
NASA Technical Reports Server (NTRS)
Obrien, C. J.; Ewen, R. L.
1981-01-01
This study identifies and evaluates promising LO2/HC rocket engine cycles, produces a consistent and reliable data base for vehicle optimization and design studies, demonstrates the significance of propulsion system improvements, and selects the critical technology areas necessary to realize an improved surface to orbit transportation system. Parametric LO2/HC engine data were generated over a range of thrust levels from 890 to 6672 kN (200K to 1.5M 1bF) and chamber pressures from 6890 to 34500 kN (1000 to 5000 psia). Engine coolants included RP-1, refined RP-1, LCH4, LC3H8, LO2, and LH2. LO2/RP-1 G.G. cycles were found to be not acceptable for advanced engines. The highest performing LO2/RP-1 staged combustion engine cycle utilizes LO2 as the coolant and incorporates an oxidizer rich preburner. The highest performing cycle for LO2/LCH4 and LO2/LC3H8 utilizes fuel cooling and incorporates both fuel and oxidizer rich preburners. LO2/HC engine cycles permitting the use of a third fluid LH2 coolant and an LH2 rich gas generator provide higher performance at significantly lower pump discharge pressures. The LO2/HC dual throat engine, because of its high altitude performance, delivers the highest payload for the vehicle configuration that was investigated.
Manley, Ray; Satiani, Bhagwan
2009-11-01
With the widening gap between overhead expenses and reimbursement, management of the revenue cycle is a critical part of a successful vascular surgery practice. It is important to review the data on all the components of the revenue cycle: payer contracting, appointment scheduling, preregistration, registration process, coding and capturing charges, proper billing of patients and insurers, follow-up of accounts receivable, and finally using appropriate benchmarking. The industry benchmarks used should be those of peers in identical groups. Warning signs of poor performance are discussed enabling the practice to formulate a performance improvement plan.
An, Geon-Hyoung; Kim, Hyeonjin; Ahn, Hyo-Jin
2018-02-21
Because of their combined effects of outstanding mechanical stability, high electrical conductivity, and high theoretical capacity, silicon (Si) nanoparticles embedded in carbon are a promising candidate as electrode material for practical utilization in Li-ion batteries (LIBs) to replace the conventional graphite. However, because of the poor ionic diffusion of electrode materials, the low-grade ultrafast cycling performance at high current densities remains a considerable challenge. In the present study, seeking to improve the ionic diffusion, we propose a novel design of mesoporous carbon skin on the Si nanoparticles embedded in carbon by hydrothermal reaction, poly(methyl methacrylate) coating process, and carbonization. The resultant electrode offers a high specific discharge capacity with excellent cycling stability (1140 mA h g -1 at 100 mA g -1 after 100 cycles), superb high-rate performance (969 mA h g -1 at 2000 mA g -1 ), and outstanding ultrafast cycling stability (532 mA h g -1 at 2000 mA g -1 after 500 cycles). The battery performances are surpassing the previously reported results for carbon and Si composite-based electrodes on LIBs. Therefore, this novel approach provides multiple benefits in terms of the effective accommodation of large volume expansions of the Si nanoparticles, a shorter Li-ion diffusion pathway, and stable electrochemical conditions from a faster ionic diffusion during cycling.
NASA Astrophysics Data System (ADS)
Hong, Pengbo; Xu, Mengqing; Zheng, Xiongwen; Zhu, Yunmin; Liao, Youhao; Xing, Lidan; Huang, Qiming; Wan, Huaping; Yang, Yongjun; Li, Weishan
2016-10-01
Ethylene glycol bis (propionitrile) ether (EGBE) is used as an electrolyte additive to improve the cycling stability and rate capability of Li/Li1.2Mn0.54Ni0.13Co0.13O2 cells at high operating voltage (4.8 V). After 150 cycles, cells with 1.0 wt% of EGBE containing electrolyte have remarkable cycling performance, 89.0% capacity retention; while the cells with baseline electrolyte only remain 67.4% capacity retention. Linear sweep voltammetry (LSV) and computation results demonstrate that EGBE preferably oxidizes on the cathode surface compared to the LiPF6/carbonate electrolyte. In order to further understand the effects of EGBE on Li1.2Mn0.54Ni0.13Co0.13O2 cathode upon cycling at high voltage, electrochemical behaviors and ex-situ surface analysis of Li1.2Mn0.54Ni0.13Co0.13O2 are investigated via electrochemical impedance spectroscopy (EIS), scanning electron spectroscopy (SEM), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), and inductive coupled plasma spectroscopy (ICP-MS). The improved cycling performance can be attributed to more stable and robust surface layer yield via incorporation of EGBE, which mitigates the oxidation of electrolyte on the cathode electrode, and also inhibits the dissolution of bulk transition metal ions as well upon cycling at high voltage.
Life Cycle Costing: A Working Level Approach
1981-06-01
Effects Analysis ( FMEA ) ...... ................ .. 59 Logistics Performance Factors (LPFs) 60 Planning the Use of Life Cycle Cost in the Demonstration...form. Failure Mode and Effects Analysis ( FMEA ). Description. FMEA is a technique that attempts to improve the design of any particular unit. The FMEA ...failure modes and also eliminate extra parts or ones that are used to achieve more performance than is necessary (16:5-14]. Advantages. FMEA forces
Dhar, Sanjay; Michel, Raquel; Kanna, Balavenkatesh
2011-01-01
Patient waiting time and waiting room congestion are quality indicators that are related to efficiency of ambulatory care systems and patient satisfaction. Our main purpose was to test a program to decrease patient visit cycle time, while maintaining high-quality healthcare in a high-volume inner-city hospital-based clinic in New York City. Use of patient flow analysis and the creation of patient care teams proved useful in identifying areas for improvement, target, and measure effectiveness of interventions. The end result is reduced visit cycle time, improved provider team performance, and sustained patient care outcomes. © 2010 National Association for Healthcare Quality.
Rutile TiO2 Mesocrystals as Sulfur Host for High-Performance Lithium-Sulfur Batteries.
Sun, Qingqing; Chen, Kaixiang; Liu, Yubin; Li, Yafeng; Wei, Mingdeng
2017-11-16
Although lithium-sulfur (Li-S) batteries are among the most promising rechargeable batteries in the field of energy-storage devices, their poor cycling performance restricts their potential applications. Polar materials can improve the cycling stability owing to their inherent strong chemical interaction with polysulfides. Herein, novel rutile TiO 2 mesocrystals (RTMs) are employed as the host for sulfur in Li-S batteries; the RTMs display a stable cycling performance with a capacity retention of 64 % and a small average capacity decay rate of 0.12 % per cycle over 300 cycles at 1 C rate. The good electrochemical properties are attributed to the interior ordered nanopores of the RTMs, which can effectively limit the dissolution of polysulfides, and the ultrafine nanowires in RTMs, which shorten the path for lithium-ion transport effectively. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darbar, Devendrasinh; Department of Mechanical Engineering, National University of Singapore, 117576; Department of Physics, National University of Singapore, 117542
2016-01-15
Highlights: • MgCo{sub 2}O{sub 4} was prepared by oxalate decomposition method and electrospinning technique. • Electrospun MgCo{sub 2}O{sub 4} shows the reversible capacity of 795 and 227 mAh g{sup −1} oxalate decomposition MgCo{sub 2}O{sub 4} after 50 cycle. • Electrospun MgCo{sub 2}O{sub 4} show good cycling stability and electrochemical performance. - Abstract: Magnesium cobalt oxide, MgCo{sub 2}O{sub 4} was synthesized by oxalate decomposition method and electrospinning technique. The electrochemical performances, structures, phase formation and morphology of MgCo{sub 2}O{sub 4} synthesized by both the methods are compared. Scanning electron microscope (SEM) studies show spherical and fiber type morphology, respectively for themore » oxalate decomposition and electrospinning method. The electrospun nanofibers of MgCo{sub 2}O{sub 4} calcined at 650 °C, showed a very good reversible capacity of 795 mAh g{sup −1} after 50 cycles when compared to bulk material capacity of 227 mAh g{sup −1} at current rate of 60 mA g{sup −1}. MgCo{sub 2}O{sub 4} nanofiber showed a reversible capacity of 411 mAh g{sup −1} (at cycle) at current density of 240 mA g{sup −1}. Improved performance was due to improved conductivity of MgO, which may act as buffer layer leading to improved cycling stability. The cyclic voltammetry studies at scan rate of 0.058 mV/s show main cathodic at around 1.0 V and anodic peaks at 2.1 V vs. Li.« less
Yi, Ting-Feng; Li, Yan-Mei; Yang, Shuang-Yuan; Zhu, Yan-Rong; Xie, Ying
2016-11-30
Layered Li-rich, Co-free, and Mn-based cathode material, Li 1.17 Ni 0.25-x Mn 0.58 Mg x O 2 (0 ≤ x ≤ 0.05), was successfully synthesized by a coprecipitation method. All prepared samples have typical Li-rich layered structure, and Mg has been doped in the Li 1.17 Ni 0.25 Mn 0.58 O 2 material successfully and homogeneously. The morphology and the grain size of all material are not changed by Mg doping. All materials have a estimated size of about 200 nm with a narrow particle size distribution. The electrochemical property results show that Li 1.17 Ni 0.25-x Mn 0.58 Mg x O 2 (x = 0.01 and 0.02) electrodes exhibit higher rate capability than that of the pristine one. Li 1.17 Ni 0.25-x Mn 0.58 Mg x O 2 (x = 0.02) indicates the largest reversible capacity of 148.3 mAh g -1 and best cycling stability (capacity retention of 95.1%) after 100 cycles at 2C charge-discharge rate. Li 1.17 Ni 0.25-x Mn 0.58 Mg x O 2 (x = 0.02) also shows the largest discharge capacity of 149.2 mAh g -1 discharged at 1C rate at elevated temperature (55 °C) after 50 cycles. The improved electrochemical performances may be attributed to the decreased polarization, reduced charge transfer resistance, enhanced the reversibility of Li + ion insertion/extraction, and increased lithium ion diffusion coefficient. This promising result gives a new understanding for designing the structure and improving the electrochemical performance of Li-rich cathode materials for the next-generation lithium-ion battery with high rate cycling performance.
Performance and sex differences in 'Isklar Norseman Xtreme Triathlon'.
Knechtle, Beat; Nikolaidis, Pantelis Theodoros; Stiefel, Michael; Rosemann, Thomas; Rüst, Christoph Alexander
2016-10-31
The performance and sex differences of long-distance triathletes competing in 'Ironman Hawaii' are well investigated. However, less information is available with regards to triathlon races of the Ironman distance held under extreme environmental conditions (e.g. extreme cold) such as the 'Isklar Norseman Xtreme Triathlon' which started in 2003. In 'Isklar Norseman Xtreme Triathlon', athletes swim at a water temperature of ~13-15°C, cycle at temperatures of ~5-20°C and run at temperatures of ~12-28°C in the valley and of ~2-12°C at Mt. Gaustatoppen. This study analysed the performance trends and sex differences in 'Isklar Norseman Xtreme Triathlon' held from 2003 to 2015 using mixed-effects regression analyses. During this period, a total of 175 women (10.6%) and 1,852 men (89.4%) successfully finished the race. The number of female (r² = 0.53, P = 0.0049) and male (r² = 0.37, P = 0.0271) finishers increased and the men-to-women ratio decreased (r² = 0.86, P < 0.0001). Men were faster than women in cycling (25.41 ± 2.84 km/h versus 24.25 ± 2.17 km/h) (P < 0.001), but not in swimming (3.06 ± 0.62 km/h vs. 2.94 ± 0.57 km/h), running (7.43 ± 1.13 km/h vs. 7.31 ± 0.93 km/h) and overall race time (874.57 ± 100.62 min vs. 899.95 ± 90.90 min) (P > 0.05). Across years, women improved in swimming and both women and men improved in cycling and in overall race time (P < 0.001). In running, however, neither women nor men improved (P > 0.05). In summary, in 'Isklar Norseman Xtreme Triathlon' from 2003 to 2015, the number of successful women increased across years, women achieved a similar performance to men in swimming, cycling and overall race time, and women improved across years in swimming, cycling and overall race time.
Enhanced performance of graphite anode materials by AlF3 coating for lithium-ion batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Fei; Xu, Wu; Choi, Daiwon
2012-04-27
In order to form the stable surface film and to further enhance the long-term cycling stability of the graphite anodes of lithium-ion batteries, the surface of graphite powders has been modified by AlF3 coating through chemical precipitation method. The AlF3-coated graphite shows no evident changes in the bulk structure and a thin AlF3-coating layer of about 2 nm thick is found to uniformly cover the graphite particles with 2 wt% AlF3 content. However, it delivers a higher initial discharge capacity and largely improved rate performances compared to the pristine graphite. Remarkably, AlF3 coated graphite demonstrated a much better cycle life.more » After 300 cycles, AlF3 coated graphite and uncoated graphite show capacity retention of 92% and 81%, respectively. XPS measurement shows that a more conductive solid electrode interface (SEI) layer was formed on AlF3 coated graphite as compared to uncoated graphite. SEM monograph also reveals that the AlF3-coated graphite particles have a much more stable surface morphology after long-term cycling. Therefore, the improved electrochemical performance of AlF3 coated graphite can be attributed to a more stable and conductive SEI formed on coated graphite anode during cycling process.« less
Rustad, Per I; Sailer, Manuela; Cumming, Kristoffer T; Jeppesen, Per B; Kolnes, Kristoffer J; Sollie, Ove; Franch, Jesper; Ivy, John L; Daniel, Hannelore; Jensen, Jørgen
2016-01-01
Intake of protein immediately after exercise stimulates protein synthesis but improved recovery of performance is not consistently observed. The primary aim of the present study was to compare performance 18 h after exhaustive cycling in a randomized diet-controlled study (175 kJ·kg(-1) during 18 h) when subjects were supplemented with protein plus carbohydrate or carbohydrate only in a 2-h window starting immediately after exhaustive cycling. The second aim was to investigate the effect of no nutrition during the first 2 h and low total energy intake (113 kJ·kg(-1) during 18 h) on performance when protein intake was similar. Eight endurance-trained subjects cycled at 237±6 Watt (~72% VO2max) until exhaustion (TTE) on three occasions, and supplemented with 1.2 g carbohydrate·kg(-1)·h(-1) (CHO), 0.8 g carbohydrate + 0.4 g protein·kg(-1)·h(-1) (CHO+PRO) or placebo without energy (PLA). Intake of CHO+PROT increased plasma glucose, insulin, and branch chained amino acids, whereas CHO only increased glucose and insulin. Eighteen hours later, subjects performed another TTE at 237±6 Watt. TTE was increased after intake of CHO+PROT compared to CHO (63.5±4.4 vs 49.8±5.4 min; p<0.05). PLA reduced TTE to 42.8±5.1 min (p<0.05 vs CHO). Nitrogen balance was positive in CHO+PROT, and negative in CHO and PLA. In conclusion, performance was higher 18 h after exhaustive cycling with intake of CHO+PROT compared to an isocaloric amount of carbohydrate during the first 2 h post exercise. Intake of a similar amount of protein but less carbohydrate during the 18 h recovery period reduced performance.
The VRLA modular wound design for 42 V mild hybrid systems
NASA Astrophysics Data System (ADS)
Trinidad, F.; Gimeno, C.; Gutiérrez, J.; Ruiz, R.; Sainz, J.; Valenciano, J.
Mild hybrid vehicles with 42 V electrical systems require advanced batteries with low cost, very high reliability and peak power performance. Valve-regulated lead-acid (VRLA) batteries could provide better performance/cost ratio than any other electrochemical couples, by improving their cycle life performance at partial state-of-charge (SoC), charge acceptance of the negative plate and thermal management under power assist conditions. Modular wound designs are being developed for this application, because they can combine the best attributes of the high power VRLA designs (low resistance and high compression) with a more efficient thermal management and could improve reliability by reducing the potential cell failures in manufacturing (better quality control could be assured for individual 3-cell modules than for complete 18-cell block batteries). Thermal management is an important issue for VRLA batteries in a power assist cycling profile. Although water cooling is very efficient, it is not economical and increases the weight of the complete storage system. The modular VRLA design allows air circulation around the external walls of every cell in order to maintain the temperature around 40 °C, even at very high power cycling profiles. In order to increase the life at higher depth-of-discharge (DoD) and consequently to optimise the weight of the complete battery systems, a new 6 V module has been designed with improved thermal management features. Cycle life performance under partial-SoC conditions (around 60% SoC) has been tested in both 6 and 12 V modules. The basic power assist profile as specified by the European car manufacturers is composed of a high power discharge (boost) period followed by a rest (cruise) and recharge in three steps (regenerative braking). Very good results have been obtained for 12 V VRLA spiral wound batteries under power assist profile (more than 200,000 cycles at 1.25% DoD, equivalent to 2500 times the nominal capacity), but smaller 6 V modules, although providing very promising results (50,000 power assist cycles at 2.5% DoD, equivalent to 1250 times the nominal capacity), still need further improvement to comply with the very demanding conditions of mild hybrid vehicles. Failure mode is related to negative active material sulfation, that could be overcome by improving charge acceptance with high surface conducting additives in the active material.
Jacobs, Robert Acton; Flück, Daniela; Bonne, Thomas Christian; Bürgi, Simon; Christensen, Peter Møller; Toigo, Marco; Lundby, Carsten
2013-09-01
Six sessions of high-intensity interval training (HIT) are sufficient to improve exercise capacity. The mechanisms explaining such improvements are unclear. Accordingly, the aim of this study was to perform a comprehensive evaluation of physiologically relevant adaptations occurring after six sessions of HIT to determine the mechanisms explaining improvements in exercise performance. Sixteen untrained (43 ± 6 ml·kg(-1)·min(-1)) subjects completed six sessions of repeated (8-12) 60 s intervals of high-intensity cycling (100% peak power output elicited during incremental maximal exercise test) intermixed with 75 s of recovery cycling at a low intensity (30 W) over a 2-wk period. Potential training-induced alterations in skeletal muscle respiratory capacity, mitochondrial content, skeletal muscle oxygenation, cardiac capacity, blood volumes, and peripheral fatigue resistance were all assessed prior to and again following training. Maximal measures of oxygen uptake (Vo2peak; ∼8%; P = 0.026) and cycling time to complete a set amount of work (∼5%; P = 0.008) improved. Skeletal muscle respiratory capacities increased, most likely as a result of an expansion of skeletal muscle mitochondria (∼20%, P = 0.026), as assessed by cytochrome c oxidase activity. Skeletal muscle deoxygenation also increased while maximal cardiac output, total hemoglobin, plasma volume, total blood volume, and relative measures of peripheral fatigue resistance were all unaltered with training. These results suggest that increases in mitochondrial content following six HIT sessions may facilitate improvements in respiratory capacity and oxygen extraction, and ultimately are responsible for the improvements in maximal whole body exercise capacity and endurance performance in previously untrained individuals.
Wang, Ziying; Lee, Jungwoo Z.; Xin, Huolin L.; ...
2016-05-30
All-solid-state lithium-ion batteries have the potential to not only push the current limits of energy density by utilizing Li metal, but also improve safety by avoiding flammable organic electrolyte. However, understanding the role of solid electrolyte – electrode interfaces will be critical to improve performance. In this paper, we conducted long term cycling on commercially available lithium cobalt oxide (LCO)/lithium phosphorus oxynitride (LiPON)/lithium (Li) cells at elevated temperature to investigate the interfacial phenomena that lead to capacity decay. STEM-EELS analysis of samples revealed a previously unreported disordered layer between the LCO cathode and LiPON electrolyte. This electrochemically inactive layer grewmore » in thickness leading to loss of capacity and increase of interfacial resistance when cycled at 80 °C. Finally, the stabilization of this layer through interfacial engineering is crucial to improve the long term performance of thin-film batteries especially under thermal stress.« less
Aluminum alloy anode materials for Li-ion batteries
NASA Astrophysics Data System (ADS)
Sun, Z. H.; Chen, Z. F.; Fu, Q. W.; Jiang, X. Y.
2017-03-01
Aluminum has larger theoretical capacity of 2235 mAh/g than that of graphite (372 mAh/g), but it has big disadvantages including shorter cycle life and higher irreversible capacity loss. Improving cycle performance can be obtained via alloying of aluminum. In this paper, two ternary aluminum alloy, Al7Cu2Fe and Al73Cu5Fe22 were prepared. The main phase of Al7Cu2Fe alloy was Al7Cu2Fe. The heat treatment increased the proportion of Al7Cu2Fe. The main phase of Al73Cu5Fe22 alloy was Al60Cu30Fe10. The heat treatment reduced the proportion of Al60Cu30Fe10. For two alloys, the heat treatment could increase discharge capacity compared with cast alloy. The discharge capacity was improved by 50%. The content of aluminum in alloys has little effect on improving cycle performance, and it has obvious influence on the phase structure of alloy with heat treatment.
Engine design considerations for 2nd generation supersonic transports
NASA Technical Reports Server (NTRS)
Howlett, R. A.
1975-01-01
The environmental and economic goals projected for advanced supersonic transports will require revolutionary improvements in propulsion systems. Variable cycle engine concepts that incorporate unique components and advanced technologies show promise in meeting these goals. Pratt & Whitney Aircraft is conducting conceptual design studies of variable cycle engine concepts under NASA sponsorship. This paper reviews some of the design considerations for these engine concepts. Emphasis is placed on jet noise abatement, reduction of emissions, performance improvements, installation considerations, hot-section characteristics and control system requirements. Two representative variable cycle engine concepts that incorporate these basic design considerations are described.
Contracting to improve your revenue cycle performance.
Welter, Terri L; Semko, George A; Miller, Tony; Lauer, Roberta
2007-09-01
The following key drivers of commercial contract variability can have a material effect on your hospital's revenue cycle: Claim form variance. Benefit design. Contract complexity. Coding variance. Medical necessity. Precertification/authorization. Claim adjudication/appeal requirements. Additional documentation requirements. Timeliness of payment. Third-party payer activity.
Improvement of the COP of the LiBr-Water Double-Effect Absorption Cycles
NASA Astrophysics Data System (ADS)
Shitara, Atsushi
Prevention of the global warming has called for a great necessity for energy saving. This applies to the improvement of the COP of absorption chiller-heaters. We started the development of the high efficiency gas-fired double-effect absorption chiller-heater using LiBr-H2O to achieve target performance in short or middle term. To maintain marketability, the volume of the high efficiency machine has been set below the equal to the conventional machine. The absorption cycle technology for improving the COP and the element technology for downsizing the machine is necessary in this development. In this study, the former is investigated. In this report, first of all the target performance has been set at cooling COP of 1.35(on HHV), which is 0.35 higher than the COP of 1.0 for conventional machines in the market. This COP of 1.35 is practically close to the maximum limit achievable by double-effect absorption chiller-heater. Next, the design condition of each element to achieve the target performance and the effect of each mean to improve the COP are investigated. Moreover, as a result of comparing the various flows(series, parallel, reverse)to which the each mean is applied, it has been found the optimum cycle is the parallel flow.
Void reactivity feedback analysis for U-based and Th-based LWR incineration cycles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindley, B.A.; Parks, G.T.; Franceschini, F.
2013-07-01
In reduced-moderation LWRs, an external supply of transuranic (TRU) can be incinerated by mixing it with a fertile isotope ({sup 238}U or {sup 232}Th) and recycling all the actinides after each cycle. Performance is limited by coolant reactivity feedback - the moderator density coefficient (MDC) must be kept negative. The MDC is worse when more TRU is loaded, but TRU feed is also needed to maintain criticality. To assess the performance of this fuel cycle in different neutron spectra, three LWRs are considered: 'reference' PWRs and reduced-moderation PWRs and BWRs. The MDC of the equilibrium cycle is analysed by reactivitymore » decomposition with perturbed coolant density by isotope and neutron energy. The results show that using {sup 232}Th as a fertile isotope yields superior performance to {sup 238}U. This is due essentially to the high resonance η of U bred from Th (U3), which increases the fissility of the U3-TRU isotope vector in the Th-fueled system relative to the U-fueled system, and also improves the MDC in a sufficiently hard spectrum. Spatial separation of TRU and U3 in the Th-fueled system renders further improvement by hardening the neutron spectrum in the TRU and softening it in the U3. This improves the TRU η and increases the negative MDC contribution from reduced thermal fission in U3. (authors)« less
Prommetta, Simaporn; Sanchaisuriya, Kanokwan; Fucharoen, Goonnapa; Yamsri, Supawadee; Chaiboonroeng, Attawut; Fucharoen, Supan
2017-06-15
Thalassemia screening program has been implemented for years in Southeast Asia, but no external quality assessment program has been established. We have developed and initiated the proficiency testing (PT) program for the first time in Thailand with the aim to assess the screening performance of laboratory staff and their competency in interpretation of the screening results. Three PT cycles per year were organized. From the first to the third cycle of the PT scheme, a total number of participant laboratories increased from 59 to 67. In each cycle, 2 PT items (assigned as blood samples of the couple) were provided. Performance evaluation was based on the accuracy of screening results, i.e . mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH) and the dichlorophenolindophenol (DCIP) test for haemoglobin E, including the competency in interpretation of screening results and assessment of foetal risk. Performance was assessed by comparing the participants' result against the assigned value. Of all 3 cycles, most laboratories reported acceptable MCV and MCH values. From the first to the third cycle, incorrect DCIP test and misinterpretation rates were decreased while incorrect risk assessment varied by cycle to cycle. Combining the accuracy of thalassemia screening and the competency in interpretation and risk assessment, approximately half of participants showed excellent performance. Improved performance observed in many laboratories reflects the achievement and benefit of the PT program which should be regularly provided.
Full suspension mountain bike improves off-road cycling performance.
Nishii, T; Umemura, Y; Kitagawa, K
2004-12-01
The purpose of the present study was to determine the effects of suspension systems on the cycling performance of cyclists during off-road bicycling. Eight elite male cyclists (67.8+/-5.8 ml/min/kg of (.-)VO(2max)) performed 30-minute riding tests on bicycles with 2 different suspension setups: front suspension (FS) and front and rear suspension (FRS). Heart rate, blood lactate concentration, pedaling power, cadence, cycling velocity, and completed distance during the trial were measured creatin kinase (CK), lactic dehydrogenase (LDH) and glutamic-oxaloacetic transaminase (GOT) were measured before and after the trials. The average cadence during the trial was significantly higher (p<0.05) with the FRS (73.6+/-6.1 rpm) than the FS (70.2+/-6.2 rpm). Subjects rode significantly faster (p<0.05) on FRS (24.1+/-2.6 km/h) than FS bikes (22.9+/-2.4 km/h), although no significant difference was observed in pedaling power (240.7+/-26.6 W vs 242.2+/-28.8 W, FS vs FRS, respectively). Serum creatin kinase increased significantly (p<0.05) at 24 h after the trial when cyclists exercised with the FS bike. We conclude that the FRS improved cycling performance over rough terrain. FRS might therefore be more suitable for cross-country mountain bike races.
NASA Astrophysics Data System (ADS)
Endoh, Kazuhiro; Matsushima, Hiroaki; Nonaka, Masayuki
HFC zeotropic refrigerant mixture R-407C is one of the promising alternatives for HCFC-22. We have found that the coefficient of performance (COP) of the refrigeration cycle using R-407C is improved by installing a temperature glide shift heat exchanger (TGSX) which takes advantage of zeotropic characteristics to an air-conditioner. We obtained the characteristics of a refrigeration cycle of experimental apparatus with comparison to those of a fundamental refrigeration cycle based on the refrigerant thermodynamic properties. We concluded that the COP improvement ratio of experimental apparatus with the TGSX to that without the TGSX is greater than that ratio which is calculated from the fundamental refrigeration cycle. This proved to be caused by the pressure loss of low pressure side which is not taken into account in the fundamental refrigeration cycle.
Vaquerizo, Víctor; Padilla, Sabino; Aguirre, José Javier; Begoña, Leire; Orive, Gorka; Anitua, Eduardo
2017-05-19
To assess the clinical efficacy and safety of a treatment based on one cycle versus two cycles of intra-articular injections of plasma rich in growth factors (PRGF-Endoret) on patients with knee osteoarthritis (OA). Ninety patients with knee OA were included and evaluated. A total of 48 patients received one cycle (OC group) (3 injections on a weekly basis), while 42 patients received two cycles of PRGF-Endoret (TC group) spaced 6 months between them. Patients were evaluated with LEQUESNE and WOMAC scores before treatment and after 48 weeks. Safety assessment was also performed. A significant reduction of all assessed outcome measures was shown for both groups at 48 weeks compared with baseline values (P < 0.001). Patients of TCs group showed a significantly higher reduction (P < 0.05) in WOMAC stiffness subscales. Regarding LEQUESNE INDEX, a significantly higher reduction was observed in the TC group in all subscales except in pain score. In the maximum walking distance subscale (MCD), the improvement rate was 31.8% higher for the TCs group compared with the OC group (P < 0.01). In addition, the TC group showed a significant improvement in LEQUESNE activities of daily living (ADV) and global subscales of 14.7 and 11.8% (P < 0.05) higher, respectively, than the OC group. Treatment with two cycles of PRGF did not show a significantly higher pain reduction compared with one cycle treatment. However, two cycles of PRGF showed a significant improvement in WOMAC stiffness, LEQUESNE MCD, LEQUESNE ADV and LEQUESNE global subscales. Therefore, patients treated with two cycles present an improvement in quality of life. II.
NASA Astrophysics Data System (ADS)
Zhang, Shiming; Tang, Tian; Ma, Zhihua; Gu, Haitao; Du, Wubing; Gao, Mingxia; Liu, Yongfeng; Jian, Dechao; Pan, Hongge
2018-03-01
The poor cycling stability of Li- and Mn-rich layered oxide cathodes used in lithium-ion batteries (LIBs) has severely limited their practical application. Unfortunately, current strategies to improve their lifecycle sacrifice initial capacity. In this paper, we firstly report the synergistic improvement of the electrochemical performance of a Li1.2Ni0.13Co0.13Mn0.54O2 (LNCMO) cathode material, including gains for capacity, cycling stability, and rate capability, by the partial substitution of Li+ ions by Mg2+ ions. Electrochemical performance is evaluated by a galvanostatic charge and discharge test and electrochemical impedance spectroscopy (EIS). Structure and morphology are characterized by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM). Compared with the substitution of transition metal (TM) ions with Mg2+ ions reported previously, the substitution of Li+ ions by Mg2+ ions not only drastically ameliorates the capacity retention and rate performance challenges of LNCMO cathodes but also markedly suppresses their voltage fading, due to the inhibition of the migration of TM ions during cycling, while also increasing the capacity of the cathode due to an increased abundance of the Li2MO3 phase.
Mixed polyanion glass cathodes: Effect of polyanion content
Kercher, Andrew K.; Kolopus, James A.; Sacci, Robert L.; ...
2017-02-18
Mixed polyanion glass cathodes in lithium-ion batteries have very high capacities (200-500 mAh/g), but currently these materials have fundamental problems with 1 st-cycle irreversible loss, cycling efficiency, and capacity fade. It is well established that polyanion substitutions into glasses can dramatically affect their physical properties, but the effect of polyanion content on the electrochemical performance has not been previously established. The proper amount of lithium and borate substitution in copper phosphate/vanadate glasses was shown to nearly eliminate 1 st-cycle irreversible loss and improve cycling efficiency. As a result, Raman and IR spectroscopy were used to identify polyanions that correlated withmore » electrochemical performance changes.« less
Two pilot studies of the effect of bicycling on balance and leg strength among older adults.
Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna
2013-01-01
Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Study 1: a cross-sectional survey of 43 adults aged 44-79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49-72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Cycling by healthy older adults appears promising for improving risk factors for falls.
Two Pilot Studies of the Effect of Bicycling on Balance and Leg Strength among Older Adults
Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna
2013-01-01
Objectives. Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Methods. Study 1: a cross-sectional survey of 43 adults aged 44–79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49–72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Results. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Conclusions. Cycling by healthy older adults appears promising for improving risk factors for falls. PMID:23690805
Menaspà, Paolo; Abbiss, Chris R
2017-01-01
Over the past few decades the possibility to capture real-time data from road cyclists has drastically improved. Given the increasing pressure for improved transparency and openness, there has been an increase in publication of cyclists' physiological and performance data. Recently, it has been suggested that the use of such performance biometrics may be used to strengthen the sensitivity and applicability of the Athlete Biological Passport (ABP) and aid in the fight against doping. This is an interesting concept which has merit, although there are several important factors that need to be considered. These factors include accuracy of the data collected and validity (and reliability) of the subsequent performance modeling. In order to guarantee high quality standards, the implementation of well-structured Quality-Systems within sporting organizations should be considered, and external certifications may be required. Various modeling techniques have been developed, many of which are based on fundamental intensity/time relationships. These models have increased our understanding of performance but are currently limited in their application, for example due to the largely unaccounted effects of environmental factors such as, heat and altitude. In conclusion, in order to use power data as a performance biometric to be integrated in the biological passport, a number of actions must be taken to ensure accuracy of the data and better understand road cycling performance in the field. This article aims to outline considerations in the quantification of cycling performance, also presenting an alternative method (i.e., monitoring race results) to allow for determination of unusual performance improvements.
Menaspà, Paolo; Abbiss, Chris R.
2017-01-01
Over the past few decades the possibility to capture real-time data from road cyclists has drastically improved. Given the increasing pressure for improved transparency and openness, there has been an increase in publication of cyclists' physiological and performance data. Recently, it has been suggested that the use of such performance biometrics may be used to strengthen the sensitivity and applicability of the Athlete Biological Passport (ABP) and aid in the fight against doping. This is an interesting concept which has merit, although there are several important factors that need to be considered. These factors include accuracy of the data collected and validity (and reliability) of the subsequent performance modeling. In order to guarantee high quality standards, the implementation of well-structured Quality-Systems within sporting organizations should be considered, and external certifications may be required. Various modeling techniques have been developed, many of which are based on fundamental intensity/time relationships. These models have increased our understanding of performance but are currently limited in their application, for example due to the largely unaccounted effects of environmental factors such as, heat and altitude. In conclusion, in order to use power data as a performance biometric to be integrated in the biological passport, a number of actions must be taken to ensure accuracy of the data and better understand road cycling performance in the field. This article aims to outline considerations in the quantification of cycling performance, also presenting an alternative method (i.e., monitoring race results) to allow for determination of unusual performance improvements. PMID:29163232
Measuring collections effort improves cash performance.
Shutts, Joe
2009-09-01
Having a satisfied work force can lead to an improved collections effort. Hiring the right people and training them ensures employee engagement. Measuring collections effort and offering incentives is key to revenue cycle success.
Advanced Li-Ion Hybrid Supercapacitors Based on 3D Graphene-Foam Composites.
Liu, Wenwen; Li, Jingde; Feng, Kun; Sy, Abel; Liu, Yangshuai; Lim, Lucas; Lui, Gregory; Tjandra, Ricky; Rasenthiram, Lathankan; Chiu, Gordon; Yu, Aiping
2016-10-05
Li-ion hybrid supercapacitors (LIHSs) have recently attracted increasing attention as a new and promising energy storage device. However, it is still a great challenge to construct novel LIHSs with high-performance due to the majority of battery-type anodes retaining the sluggish kinetics of Li-ion storage and most capacitor-type cathodes with low specific capacitance. To solve this problem, 3D graphene-wrapped MoO 3 nanobelt foam with the unique porous network structure has been designed and prepared as anode material, which delivers high capacity, improved rate performance, and enhanced cycle stability. First-principles calculation reveals that the combination of graphene dramatically reduces the diffusion energy barrier of Li + adsorbed on the surface of MoO 3 nanobelt, thus improving its electrochemical performance. Furthermore, 3D graphene-wrapped polyaniline nanotube foam derived carbon is employed as a new type of capacitor-type cathode, demonstrating high specific capacitance, good rate performance, and long cycle stability. Benefiting from these two graphene foam-enhanced materials, the constructed LIHSs show a wide operating voltage range (3.8 V), a long stable cycle life (90% capacity retention after 3000 cycles), a high energy density (128.3 Wh·kg -1 ), and a high power density (13.5 kW·kg -1 ). These encouraging performances indicate that the obtained LIHSs may have promising prospect as next-generation energy-storage devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddalena, Randy; Lunden, Melissa; Wilson, Daniel
2012-08-01
Air pollution levels in Ulaanbaatar, Mongolia’s capital, are among the highest in the world. A primary source of this pollution is emissions from traditional coal - burning space heating stoves used in the Ger (tent) regions around Ulaanbaatar. Significant investment has been made to replace traditional heating stoves with improved low - emission high-efficiency stoves. Testing performed to support selection of replacement stoves or for optimizing performance may not be representative of true field performance of the improved stoves. Field observations and lab measurements indicate that performance is impacted , often adversely, by how stoves are actually being used inmore » the field. The objective of this project is to identify factors that influence stove emissions under typical field operating conditions and to quantify the impact of these factors. A highly - instrumented stove testing facility was constructed to allow for rapid and precise adjustment of factors influencing stove performance. Tests were performed using one of the improved stove models currently available in Ulaanbaatar. Complete burn cycles were conducted with Nailakh coal from the Ulaanbaatar region using various startup parameters, refueling conditions , and fuel characteristics . Measurements were collected simultaneously from undiluted chimney gas, diluted gas drawn directly from the chimney and plume gas collected from a dilution tunnel above the chimney. CO, CO 2, O 2, temperature, pressure, and particulate matter (PM) were measured . We found that both refueling events and coal characteristics strongly influenced PM emissions and stove performance. Start-up and refueling events lead to increased PM emissions with more than 98% of PM mass emitted during the 20% of the burn where coal ignition occurs. CO emissions are distributed more evenly over the burn cycle, peaking both during ignition and late in the burn cycle . We anticipate these results being useful for quantifying public health outcomes related to the distribution of improved stoves and to identify opportunities for improving and sustaining performance of the new stoves .« less
Jet engine performance enhancement through use of a wave-rotor topping cycle
NASA Technical Reports Server (NTRS)
Wilson, Jack; Paxson, Daniel E.
1993-01-01
A simple model is used to calculate the thermal efficiency and specific power of simple jet engines and jet engines with a wave-rotor topping cycle. The performance of the wave rotor is based on measurements from a previous experiment. Applied to the case of an aircraft flying at Mach 0.8, the calculations show that an engine with a wave rotor topping cycle may have gains in thermal efficiency of approximately 1 to 2 percent and gains in specific power of approximately 10 to 16 percent over a simple jet engine with the same overall compression ratio. Even greater gains are possible if the wave rotor's performance can be improved.
NASA Astrophysics Data System (ADS)
Xie, Yanting; Yang, Rudong; Yan, Lan; Qi, Lu; Dai, Kehua; He, Ping
The spinel phases of Li 1.05RE xCr yMn 2- x- yO 4 (RE = Sc, Ce, Pr, Tb; 0 ≤ x ≤ 0.05; 0 ≤ y ≤ 0.1) were prepared by a soft chemical method. The structural and electrochemical properties of Li 1.05RE xCr yMn 2- x- yO 4 were investigated by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and charge-discharge experiments. Rare earth element-Sc and transition metal-Cr as co-substituents stabilize the spinel framework and improve charge-discharge performance. For Li 1.05Sc 0.01Cr 0.03Mn 1.96O 4, the capacity of the cell maintained 95% of the initial capacity at the 80th cycle. The rare earth elements of the variable valent metals such as Ce 3+/4+, Pr 3+/4+, Tb 3+/4+ with transition metal Cr 3+ as co-substituent do not stable framework of spinel or improve the cycling performance. Cyclic voltammetry (CV) were measured to provide clues for the improved cycling performance of cathode electrodes.
Goldfield, Gary S; Adamo, Kristi B; Rutherford, Jane; Murray, Marisa
2012-01-01
To evaluate effects of stationary cycling to music versus interactive video game cycling on psychosocial functioning in obese adolescents. 30 obese adolescents aged 12-17 years were randomized to twice weekly laboratory-based sessions of stationary cycling to music or interactive video game cycling for a 10-week trial. Participant's self-reported measures of scholastic competence, social competence, athletic competence, body image, and self-esteem were obtained. Aerobic fitness and body composition were directly measured. Although no differences emerged between exercise groups over time, when collapsed across exercise modality, significant pre-post improvements were found for body image, perceived scholastic competence and social competence. Changes in aerobic fitness, but not body composition, were positively associated with psychosocial functioning. Aerobic exercise was associated with improvements in body image, perceived academic performance, and social competence in obese adolescents, and these psychological benefits were related to improved aerobic fitness but not changes in body composition.
Tay, Laura; Lim, Wee Shiong; Chan, Mark; Ali, Noorhazlina; Chong, Mei Sian
2016-01-01
Gait disorders are common in early dementia, with particularly pronounced dual-task deficits, contributing to the increased fall risk and mobility decline associated with cognitive impairment. This study examines the effects of a combined cognitive stimulation and physical exercise programme (MINDVital) on gait performance under single- and dual-task conditions in older adults with mild dementia. Thirty-nine patients with early dementia participated in a multi-disciplinary rehabilitation programme comprising both physical exercise and cognitive stimulation. The programme was conducted in 8-week cycles with participants attending once weekly, and all participants completed 2 successive cycles. Cognitive, functional performance and behavioural symptoms were assessed at baseline and at the end of each 8-week cycle. Gait speed was examined under both single- (Timed Up and Go and 6-metre walk tests) and dual-task (animal category and serial counting) conditions. A random effects model was performed for the independent effect of MINDVital on the primary outcome variable of gait speed under dual-task conditions. The mean age of patients enroled in the rehabilitation programme was 79 ± 6.2 years; 25 (64.1%) had a diagnosis of Alzheimer's dementia, and 26 (66.7%) were receiving a cognitive enhancer therapy. There was a significant improvement in cognitive performance [random effects coefficient (standard error) = 0.90 (0.31), p = 0.003] and gait speed under both dual-task situations [animal category: random effects coefficient = 0.04 (0.02), p = 0.039; serial counting: random effects coefficient = 0.05 (0.02), p = 0.013], with reduced dual-task cost for gait speed [serial counting: random effects coefficient = -4.05 (2.35), p = 0.086] following successive MINDVital cycles. No significant improvement in single-task gait speed was observed. Improved cognitive performance over time was a significant determinant of changes in dual-task gait speed [random effects coefficients = 0.01 (0.005), p = 0.048, and 0.02 (0.005), p = 0.003 for category fluency and counting backwards, respectively]. A combined physical and cognitive rehabilitation programme leads to significant improvements in dual-task walking in early dementia, which may be contributed by improvement in cognitive performance, as single-task gait performance remained stable. © 2016 S. Karger AG, Basel.
Ghosh, Arnab; Shukla, Swapnil; Khosla, Gaganpreet Singh; Lochab, Bimlesh; Mitra, Sagar
2016-01-01
A sulfur-rich copolymer, poly(S-r-C-a) has been synthesized via a sustainable route, showing the utility of two major industrial wastes- elemental sulfur (petroleum waste) and cardanol (agro waste), to explore its potential as cathode material for Li-S batteries. The sulfur-rich copolymer exhibited a reduction in the active material dissolution into the electrolyte and a low self-discharge rate behavior during the rest time compared to an elemental sulfur cathode, indicating the chemical confinement of sulfur units. The presence of organosulfur moieties in copolymer suppress the irreversible deposition of end-discharge products on electrode surfaces and thus improve the electrochemical performances of Li-S batteries. This sulfur copolymer offered a reversible capacity of 892 mA h g−1 at 2nd cycle and maintained the capacity of 528 mA h g−1 after 50 cycles at 200 mA g−1. Reduced graphene oxide (rGO) prepared via a sustainable route was used as a conductive filler to extract the better electrochemical performances from this sulfur copolymer. Such sustainable origin batteries prepared via economically viable showed an improved specific capacity of ~975 mA h g−1 after 100 cycles at 200 mA g−1 current rate with capacity fading of 0.15% per cycle and maintained a stable performance over 500 cycles at 2000 mA g−1. PMID:27121089
NASA Astrophysics Data System (ADS)
Dubey, M.; Chandra, H.; Kumar, Anil
2016-02-01
A thermal modelling for the performance evaluation of gas turbine cogeneration system with reheat is presented in this paper. The Joule-Brayton cogeneration reheat cycle is based on the total useful energy rate (TUER) has been optimised and the efficiency at the maximum TUER is determined. The variation of maximum dimensionless TUER and efficiency at maximum TUER with respect to cycle temperature ratio have also been analysed. From the results, it has been found that the dimensionless maximum TUER and the corresponding thermal efficiency decrease with the increase in power to heat ratio. The result also shows that the inclusion of reheat significantly improves the overall performance of the cycle. From the thermodynamic performance point of view, this methodology may be quite useful in the selection and comparison of combined energy production systems.
Cycle training induces muscle hypertrophy and strength gain: strategies and mechanisms.
Ozaki, Hayao; Loenneke, J P; Thiebaud, R S; Abe, T
2015-03-01
Cycle training is widely performed as a major part of any exercise program seeking to improve aerobic capacity and cardiovascular health. However, the effect of cycle training on muscle size and strength gain still requires further insight, even though it is known that professional cyclists display larger muscle size compared to controls. Therefore, the purpose of this review is to discuss the effects of cycle training on muscle size and strength of the lower extremity and the possible mechanisms for increasing muscle size with cycle training. It is plausible that cycle training requires a longer period to significantly increase muscle size compared to typical resistance training due to a much slower hypertrophy rate. Cycle training induces muscle hypertrophy similarly between young and older age groups, while strength gain seems to favor older adults, which suggests that the probability for improving in muscle quality appears to be higher in older adults compared to young adults. For young adults, higher-intensity intermittent cycling may be required to achieve strength gains. It also appears that muscle hypertrophy induced by cycle training results from the positive changes in muscle protein net balance.
Effect of steam addition on cycle performance of simple and recuperated gas turbines
NASA Technical Reports Server (NTRS)
Boyle, R. J.
1979-01-01
Results are presented for the cycle efficiency and specific power of simple and recuperated gas turbine cycles in which steam is generated and used to increase turbine flow. Calculations showed significant improvements in cycle efficiency and specific power by adding steam. The calculations were made using component efficiencies and loss assumptions typical of stationary powerplants. These results are presented for a range of operating temperatures and pressures. Relative heat exchanger size and the water use rate are also examined.
NASA Astrophysics Data System (ADS)
Shobukawa, Hitoshi; Alvarado, Judith; Yang, Yangyuchen; Meng, Ying Shirley
2017-08-01
Lithium ion batteries (LIBs) containing silicon (Si) as a negative electrode have gained much attention recently because they deliver high energy density. However, the commercialization of LIBs with Si anode is limited due to the unstable electrochemical performance associated with expansion and contraction during electrochemical cycling. This study investigates the electrochemical performance and degradation mechanism of a full cell containing Si composite anode and LiFePO4 (lithium iron phosphate (LFP)) cathode. Enhanced electrochemical cycling performance is observed when the full cell is cycled with fluoroethylene carbonate (FEC) additive compared to the standard electrolyte. To understand the improvement in the electrochemical performance, x-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) are used. Based on the electrochemical behavior, FEC improves the reversibility of lithium ion diffusion into the solid electrolyte interphase (SEI) on the Si composite anode. Moreover, XPS analysis demonstrates that the SEI composition generated from the addition of FEC consists of a large amount of LiF and less carbonate species, which leads to better capacity retention over 40 cycles. The effective SEI successively yields more stable capacity retention and enhances the reversibility of lithium ion diffusion through the interphase of the Si anode, even at higher discharge rate. This study contributes to a basic comprehension of electrochemical performance and SEI formation of LIB full cells with a high loading Si composite anode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isabella J van Rooyen
2012-09-01
Nuclear fuel performance is a significant driver of nuclear power plant operational performance, safety, economics and waste disposal requirements. The Advanced Light Water Reactor (LWR) Nuclear Fuel Development Pathway focuses on improving the scientific knowledge basis to enable the development of high-performance, high burn-up fuels with improved safety and cladding integrity and improved nuclear fuel cycle economics. To achieve significant improvements, fundamental changes are required in the areas of nuclear fuel composition, cladding integrity, and fuel/cladding interaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isabella J van Rooyen
2013-01-01
Nuclear fuel performance is a significant driver of nuclear power plant operational performance, safety, economics and waste disposal requirements. The Advanced Light Water Reactor (LWR) Nuclear Fuel Development Pathway focuses on improving the scientific knowledge basis to enable the development of high-performance, high burn-up fuels with improved safety and cladding integrity and improved nuclear fuel cycle economics. To achieve significant improvements, fundamental changes are required in the areas of nuclear fuel composition, cladding integrity, and fuel/cladding interaction.
Rana, Anwar Manzoor; Akbar, Tahira; Ismail, Muhammad; Ahmad, Ejaz; Hussain, Fayyaz; Talib, Ijaz; Imran, Muhammad; Mehmood, Khalid; Iqbal, Khalid; Nadeem, M. Younus
2017-01-01
Resistance switching characteristics of CeO2/Ti/CeO2 tri-layered films sandwiched between Pt bottom electrode and two different top electrodes (Ti and TaN) with different work functions have been investigated. RRAM memory cells composed of TaN/CeO2/Ti/CeO2/Pt reveal better resistive switching performance instead of Ti/CeO2/Ti/CeO2/Pt memory stacks. As compared to the Ti/CeO2 interface, much better ability of TaN/CeO2 interface to store and exchange plays a key role in the RS performance improvement, including lower forming/SET voltages, large memory window (~102) and no significant data degradation during endurance test of >104 switching cycles. The formation of TaON thinner interfacial layer between TaN TE and CeO2 film is found to be accountable for improved resistance switching behavior. Partial charge density of states is analyzed using density functional theory. It is found that the conductive filaments formed in CeO2 based devices is assisted by interstitial Ti dopant. Better stability and reproducibility in cycle-to-cycle (C2C) resistance distribution and Vset/Vreset uniformity were achieved due to the modulation of current conduction mechanism from Ohmic in low field region to Schottky emission in high field region. PMID:28079056
Analysis of a domestic refrigerator cycle with an ejector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tomasek, M.L.; Radermacher, R.
1995-08-01
In this paper, an improved cooling cycle for a conventional domestic refrigerator-freezer utilizing an ejector for vapor precompression is analyzed using an idealized model Its energy efficiency is compared to that of the conventional refrigerator-freezer system. Emphasis is placed on off-design conditions. The ejector-enhanced refrigeration cycle consists of two evaporators that operate at different pressure and temperature levels. The ejector combines the vapor flows exiting the two evaporators into one at an intermediate pressure level The ejector cycle gives an increase of up to 12.4% in the coefficient of performance (COP) compared to that of a standard refrigerator-freezer refrigeration cycle.more » The analysis includes calculations on the optimum throat diameters of the ejector. The investigation on the off-design performance of the ejector cycle shows little dependency of energy consumption on constant ejector throat diameters.« less
Evaluation of undeveloped rocket engine cycle applications to advanced transportation
NASA Technical Reports Server (NTRS)
1990-01-01
Undeveloped pump-fed, liquid propellant rocket engine cycles were assessed and evaluated for application to Next Manned Transportation System (NMTS) vehicles, which would include the evolving Space Transportation System (STS Evolution), the Personnel Launch System (PLS), and the Advanced Manned Launch System (AMLS). Undeveloped engine cycles selected for further analysis had potential for increased reliability, more maintainability, reduced cost, and improved (or possibly level) performance when compared to the existing SSME and proposed STME engines. The split expander (SX) cycle, the full flow staged combustion (FFSC) cycle, and a hybrid version of the FFSC, which has a LOX expander drive for the LOX pump, were selected for definition and analysis. Technology requirements and issues were identified and analyses of vehicle systems weight deltas using the SX and FFSC cycles in AMLS vehicles were performed. A strawman schedule and cost estimate for FFSC subsystem technology developments and integrated engine system demonstration was also provided.
Fridén, Cecilia; Hirschberg, Angelica Lindén; Saartok, Tönu; Renström, Per
2006-04-01
An increased incidence of sports related injuries in the premenstrual phase as well as in the menstrual phase of the menstrual cycle has been described. This may be explained by alterations in proprioception and neuromuscular coordination due to hormonal variations. Prospective, within women analysis of knee joint kinesthesia and neuromuscular coordination were performed by repeated measures analysis of variance in three hormonally verified phases of three consecutive menstrual cycles. Thirty-two healthy, moderately active female subjects volunteered to participate in the study. Twenty-five of the subjects performed at least one hormonally verified menstrual cycle. A specially designed device was used to investigate knee joint kinaesthesia and neuromuscular coordination was measured with the square hop test. These tests were carried out in the menstrual phase, ovulation phase and premenstrual phase determined by hormone analyses in three consecutive menstrual cycles. An impaired knee joint kinaesthesia was detected in the premenstrual phase and the performance of square hop test was significantly improved in the ovulation phase compared to the other two phases. The results of this study indicate that the variation of sex hormones in the menstrual cycle has an effect on performance of knee joint kinaesthesia and neuromuscular coordination.
Maas, Marjo J M; Nijhuis-van der Sanden, Maria W G; Driehuis, Femke; Heerkens, Yvonne F; van der Vleuten, Cees P M; van der Wees, Philip J
2017-02-10
To evaluate the feasibility of a quality improvement programme aimed to enhance the client-centeredness, effectiveness and transparency of physiotherapy services by addressing three feasibility domains: (1) acceptability of the programme design, (2) appropriateness of the implementation strategy and (3) impact on quality improvement. Mixed methods study. 64 physiotherapists working in primary care, organised in a network of communities of practice in the Netherlands. The programme contained: (1) two cycles of online self-assessment and peer assessment (PA) of clinical performance using client records and video-recordings of client communication followed by face-to-face group discussions, and (2) clinical audit assessing organisational performance. Assessment was based on predefined performance indicators which could be scored on a 5-point Likert scale. Discussions addressed performance standards and scoring differences. All feasibility domains were evaluated qualitatively with two focus groups and 10 in-depth interviews. In addition, we evaluated the impact on quality improvement quantitatively by comparing self-assessment and PA scores in cycles 1 and 2. We identified critical success features relevant to programme development and implementation, such as clarifying expectations at baseline, training in PA skills, prolonged engagement with video-assessment and competent group coaches. Self-reported impact on quality improvement included awareness of clinical and organisational performance, improved evidence-based practice and client-centeredness and increased motivation to self-direct quality improvement. Differences between self-scores and peer scores on performance indicators were not significant. Between cycles 1 and 2, scores for record keeping showed significant improvement, however not for client communication. This study demonstrated that bottom-up initiatives to improve healthcare quality can be effective. The results justify ongoing evaluation to inform nationwide implementation when the critical success features are addressed. Further research is necessary to explore the sustainability of the results and the impact on client outcomes in a full-scale study. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
High performance millimeter-wave microstrip circulators and isolators
NASA Technical Reports Server (NTRS)
Shih, Ming; Pan, J. J.
1990-01-01
Millimeter wave systems, phased array antennas, and high performance components all require wideband circulators (and isolators) to perform diplexing and switching, to improve isolation and Voltage Standing Wave Ratio (VSWR), and to construct IMPATT diode reflection amplifiers. Presently, most of the millimeter-wave circulators and isolators are available in the configurations of waveguide or stripline, both of which suffer from the shortcomings of bulky size/weight, narrow bandwidth, and poor compatibility with monolithic millimeter-wave integrated circuits (MMIC). MMW microstrip circulators/isolators can eliminate or improve these shortcomings. Stub-tuned microstrip circulator configuration were developed utilizing the electromagnetic fields perturbation technique, the adhesion problems of microstrip metallization on new ferrite substrate were overcome, the fabrication, assembly, packaging techniques were improved, and then successfully designed, fabricated a Ka band circulator which has isolation and return loss of greater than 16dB, insertion loss less than 0.7dB. To assess the steady and reliable performance of the circulator, a temperature cycling test was done over the range of -20 to +50 C for 3 continuous cycles and found no significant impact or variation of circulator performance.
[Stimulation of D2-receptors improves passive avoidance learning in female rats].
Fedotova, Iu O
2012-01-01
The involvement of D2-receptors in learning/memory processes during ovary cycle was assessed in the adult female rats. Quinperole (0,1 mg/kg, i.p.), D2-receptor agonist and sulpiride (10,0 mg/kg, i.p.), D2-receptor antagonist were injected chronically to adult female rats. Learning of these animals was assessed in different models: passive avoidance performance and Morris water maze. Chronic quinperole administration to females resulted in the appearance of the passive avoidance performance in proestrous and estrous, as distinct from the control animals. Also, quinperole improved spatial learning in proestrous and stimulated it in estrous in Morris water maze. Chronic sulpiride administration similarly impaired non-spatial and spatial learning in females during all phases of ovary cycle. The results of the study suggest modulating role of D2-receptors in learning/memory processes during ovary cycle in the adult female rats.
Testing and development of electric vehicle batteries for EPRI Electric Transportation Program
NASA Astrophysics Data System (ADS)
1985-11-01
Argonne National Laboratory conducted an electric-vehicle battery testing and development program for the Electric Power Research Institute. As part of this program, eighteen battery modules previously developed by Johnson Controls, Inc. were tested. This type of battery (EV-2300 - an improved state-of-the-art lead-acid battery) was designed specifically for improved performance, range, and life in electric vehicles. In order to obtain necessary performance data, the batteries were tested under various duty cycles typical of normal service. This program, supported by the Electric Power Research Institute, consisted of three tasks: determination of the effect of cycle life vs peak power and rest period, determination of the impact of charge method on cycle life, and evaluation of the EV-2300 battery system. Two supporting studies were also carried out: one on thermal management of electric-vehicle batteries and one on enhanced utilization of active material in lead-acid batteries.
Cryogenic Flange and Seal Evaluation
NASA Technical Reports Server (NTRS)
Ramirez, Adrian
2014-01-01
The assembly of flanges, seals, and pipes are used to carry cryogenic fluid from a storage tank to the vehicle at launch sites. However, after a certain amount of cycles these raised face flanges with glass-filled Teflon gaskets have been found to have torque relaxation and are as a result susceptible to cryogenic fluid leakage if not re-torqued. The intent of this project is to identify alternate combinations of flanges and seals which may improve thermal cycle performance and decrease re-torque requirements. The general approach is to design a test fixture to evaluate leak characteristics between spiral and concentric serrations and to test alternate flange and seal combinations. Due to insufficient time, it was not possible to evaluate these different types of combinations for the combination that improved thermal cycle performance the most. However, the necessary drawings for the test fixture were designed and assembled along with the collection of the necessary parts.
The CF6 jet engine performance improvement: New front mount
NASA Technical Reports Server (NTRS)
Fasching, W. A.
1979-01-01
The New Front Mount was evaluated in component tests including stress, deflection/distortion and fatigue tests. The test results demonstrated a performance improvement of 0.1% in cruise sfc, 16% in compressor stall margin and 10% in compressor stator angle margin. The New Front Mount hardware successfully completed 35,000 simulated flight cycles endurance testing.
Using Performance Tasks to Improve Quantitative Reasoning in an Introductory Mathematics Course
ERIC Educational Resources Information Center
Kruse, Gerald; Drews, David
2013-01-01
A full-cycle assessment of our efforts to improve quantitative reasoning in an introductory math course is described. Our initial iteration substituted more open-ended performance tasks for the active learning projects than had been used. Using a quasi-experimental design, we compared multiple sections of the same course and found non-significant…
NASA Technical Reports Server (NTRS)
Smart, M.; Ratnakumar, B. V.; Surampudi, S.; Crott, H.; Tice, D.; Staniewicz, R.
2001-01-01
Lithium-ion rechargeable batteries are being developed for various aerospace applications under a NASA-DoD interagency program. For the projected missions, lithium ion batteries need to be further improved, i.e., low temperature performance for Mars Landers, Rovers, and Penetrators and cycle life for the Orbiters and LEO and GEO satellites.
ENGINEL: A single rotor turbojet engine cycle match performance program
NASA Technical Reports Server (NTRS)
Lovell, W. A.
1977-01-01
ENGINEL is a computer program which was developed to generate the design and off-design performance of a single rotor turbojet engine with or without afterburning using a cycle match procedure. It is capable of producing engine performance over a wide range of altitudes and Mach numbers. The flexibility, of operating with a variable geometry turbine, for improved off-design fuel consumption or with a fixed geometry turbine as in conventional turbojets, has been incorporated. In addition, the option of generation engine performance with JP4, liquid hydrogen or methane as fuel is provided.
Advanced Launch Technology Life Cycle Analysis Using the Architectural Comparison Tool (ACT)
NASA Technical Reports Server (NTRS)
McCleskey, Carey M.
2015-01-01
Life cycle technology impact comparisons for nanolauncher technology concepts were performed using an Affordability Comparison Tool (ACT) prototype. Examined are cost drivers and whether technology investments can dramatically affect the life cycle characteristics. Primary among the selected applications was the prospect of improving nanolauncher systems. As a result, findings and conclusions are documented for ways of creating more productive and affordable nanolauncher systems; e.g., an Express Lane-Flex Lane concept is forwarded, and the beneficial effect of incorporating advanced integrated avionics is explored. Also, a Functional Systems Breakdown Structure (F-SBS) was developed to derive consistent definitions of the flight and ground systems for both system performance and life cycle analysis. Further, a comprehensive catalog of ground segment functions was created.
Meneghetti, Stefano; Gaiotti, Federica; Giust, Mirella; Belfiore, Nicola; Tomasi, Diego
2015-03-01
This study uses PCR-derived marker systems to investigate the genetic differences of 22 grapevine accessions obtained through a self-fertilization program using Gaglioppo and Magliocco dolce. The aim of the study was to improve some qualitative parameters, while preserving the adaptive characteristics of these two cultivars to the adverse environmental conditions of the Calabria region (southern Italy). These two Calabrian grapevines have been cultivated within a restricted area and have been placed under a strong anthropic pressure which has limited their phenotypical variability with no selection of higher performant biotypes. Therefore, to have accessions with improved qualitative traits, a program of genetic improvement based on the self-fertilization of Gaglioppo and Magliocco dolce cultivars was performed in 1998, producing 3,122 accessions. Selection cycles were performed in 14 years. A first selection cycle (1998-2000), based on visual inspection of vegetative traits, selected 1,320 accessions, planted in an experimental vineyard in 2000. A second selection cycle (2000-2008), based on phenotypic traits, sanitary aspects, and chemical composition of the grapes, selected 42 accessions, planted in a new experimental vineyard in 2008. A final selection cycle (2008-2012), produced 22 accessions (virus free), with the best agronomic, sanitary, and qualitative aspects: two accessions obtained from Gaglioppo have been selected by color characteristics (i.e., anthocyanin total content and stability); 20 genotypes obtained from Magliocco dolce had a better macro-composition of the grape (i.e., good sugar content with a balanced acidity). SSR analyses were performed to check the self-fertilization process. The study of genetic differences between accessions was performed by AFLPs, SAMPLs, and M-AFLPs. The application of the above-mentioned techniques allowed both to discriminate molecularly the 22 accessions grouped these accessions according to their genetic similarity. The self-fertilization approach has enabled improvement in the quality of the grapes, while preserving the high degree of adaptation to the environment of these two native Calabrian cultivars in southern Italy.
A preliminary evaluation of a reusable digital sterilization indicator prototype.
Puttaiah, R; Griggs, J; D'Onofrio, M
2014-09-01
Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles in an autoclave. In this study, the final batch of the DS1922F prototype data logger was found to be robust in withstanding the challenge of 600 autoclave cycles, with a mean lifetime of more than 450 cycles, multiple times more than prescribed number of cycles. Instrument reprocessing is among the important aspects of infection control. While stringent procedures are followed in instrument reprocessing within the clinic in assuring patient safety, regular use of sterilization process indicators and periodic biological validation of the sterilizer's performance is necessary. Chemical indicators for use in Autoclaves provide information on whether the particular cycle's parameters were achieved but do not provide at what specific point in time or temperature the failure occurred. Data loggers and associated reader software as the tested prototype in this evaluation (DS1922F), are designed to provide continuous information on time and temperature of the prescribed cycle. Data loggers provide immediate information on the process as opposed to Biological Indicators that take from days to a week in obtaining a confirmatory result. Further, many countries do not have the sterilization monitoring service infrastructure to meet the demands of the end users. In the absence of sterilization monitoring services, use of digital data loggers for each sterilization cycle is more pragmatic.
NASA's Earth Science Enterprise's Water and Energy Cycle Focus Area
NASA Astrophysics Data System (ADS)
Entin, J. K.
2004-05-01
Understanding the Water and Energy cycles is critical towards improving our understanding of climate change, as well as the consequences of climate change. In addition, using results from water and energy cycle research can help improve water resource management, agricultural efficiency, disaster management, and public health. To address this, NASA's Earth Science Enterprise (ESE) has an end-to-end Water and Energy Cycle Focus Area, which along with the ESE's other five focus areas will help NASA answer key Earth Science questions. In an effort to build upon the pre-existing discipline programs, which focus on precipitation, radiation sciences, and terrestrial hydrology, NASA has begun planning efforts to create an implementation plan for integrative research to improve our understanding of the water and energy cycles. The basics of this planning process and the core aspects of the implementation plan will be discussed. Roadmaps will also be used to show the future direction for the entire focus area. Included in the discussion, will be aspects of the end-to-end nature of the Focus Area that encompass current and potential actives to extend research results to operational agencies to enable improved performance of policy and management decision support systems.
Improvement of Ice Hockey Players' On-Ice Sprint With Combined Plyometric and Strength Training.
Dæhlin, Torstein E; Haugen, Ole C; Haugerud, Simen; Hollan, Ivana; Raastad, Truls; Rønnestad, Bent R
2017-08-01
Combined plyometric and strength training has previously been suggested as a strategy to improve skating performance in ice hockey players. However, the effects of combined plyometric and strength training have not previously been compared with the effects of strength training only. To compare the effects of combined plyometric and strength training on ice hockey players' skating sprint performance with those of strength training only. Eighteen participants were randomly assigned to 2 groups that completed 5 strength-training sessions/wk for 8 wk. One group included plyometric exercises at the start of 3 sessions/wk (PLY+ST), and the other group included core exercises in the same sessions (ST). Tests of 10- and 35-m skating sprints, horizontal jumping, 1-repetition-maximum (1 RM) squat, skating multistage aerobic test (SMAT), maximal oxygen consumption, repeated cycle sprints, and body composition were performed before and after the intervention. The participants increased their 1RM squat, lean mass, and body mass (P < .05), with no difference between the groups. Furthermore, they improved their 3×broad jump, repeated cycle sprint, and SMAT performance (P < .05), with no difference between the groups. PLY+ST gained a larger improvement in 10-m on-ice sprint performance than ST (P < .025). Combining plyometric and strength training for 8 wk was superior to strength training alone at improving 10-m on-ice sprint performance in high-level ice hockey players.
A POM–organic framework anode for Li-ion battery
Yue, Yanfeng; Li, Yunchao; Bi, Zhonghe; ...
2015-10-12
Rechargeable Li-ion batteries (LIBs) are currently the dominant power source for portable electronic devices and electric vehicles, and for small-scale stationary energy storage. However, one bottleneck of the anode materials for LIBs is the poor cycling performance caused by the fact that the anodes cannot maintain their integrity over several charge–discharge cycles. In this work, we demonstrate an approach to improving the cycling performance of lithium-ion battery anodes by constructing an extended 3D network of flexible redox active polyoxometalate (POM) clusters with redox active organic linkers, herein described as POMOF. In addition, this architecture enables the accommodation of large volumemore » changes during cycling at relatively high current rates. For example, the POMOF anode exhibits a high reversible capacity of 540 mA h g –1 after 360 cycles at a current rate of 0.25C and a long cycle life at a current rate of 1.25C (>500 cycles).« less
Laskar, Masihhur R; Jackson, David H K; Guan, Yingxin; Xu, Shenzhen; Fang, Shuyu; Dreibelbis, Mark; Mahanthappa, Mahesh K; Morgan, Dane; Hamers, Robert J; Kuech, Thomas F
2016-04-27
Metal oxide coatings can improve the electrochemical stability of cathodes and hence, their cycle-life in rechargeable batteries. However, such coatings often impose an additional electrical and ionic transport resistance to cathode surfaces leading to poor charge-discharge capacity at high C-rates. Here, a mixed oxide (Al2O3)1-x(Ga2O3)x alloy coating, prepared via atomic layer deposition (ALD), on Li[Ni0.5Mn0.3Co0.2]O2 (NMC) cathodes is developed that has increased electron conductivity and demonstrated an improved rate performance in comparison to uncoated NMC. A "co-pulsing" ALD technique was used which allows intimate and controlled ternary mixing of deposited film to obtain nanometer-thick mixed oxide coatings. Co-pulsing allows for independent control over film composition and thickness in contrast to separate sequential pulsing of the metal sources. (Al2O3)1-x(Ga2O3)x alloy coatings were demonstrated to improve the cycle life of the battery. Cycle tests show that increasing Al-content in alloy coatings increases capacity retention; whereas a mixture of compositions near (Al2O3)0.5(Ga2O3)0.5 was found to produce the optimal rate performance.
Bentley, David J; Cox, Gregory R; Green, Daniel; Laursen, Paul B
2008-07-01
Triathlon is a sport consisting of sequential swimming, cycling and running. The main diversity within the sport of triathlon resides in the varying event distances, which creates specific technical, physiological and nutritional considerations for athlete and practitioner alike. The purpose of this article is to review physiological as well as nutritional aspects of triathlon and to make recommendations on ways to enhance performance. Aside from progressive conditioning and training, areas that have shown potential to improve triathlon performance include drafting when possible during both the swim and cycle phase, wearing a wetsuit, and selecting a lower cadence (60-80 rpm) in the final stages of the cycle phase. Adoption of a more even racing pace during cycling may optimise cycling performance and induce a "metabolic reserve" necessary for elevated running performance in longer distance triathlon events. In contrast, drafting in swimming and cycling may result a better tactical approach to increase overall performance in elite Olympic distance triathlons. Daily energy intake should be modified to reflect daily training demands to assist triathletes in achieving body weight and body composition targets. Carbohydrate loading strategies and within exercise carbohydrate intake should reflect the specific requirements of the triathlon event contested. Development of an individualised fluid plan based on previous fluid balance observations may assist to avoid both dehydration and hyponatremia during prolonged triathlon racing.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1976-01-01
Considerable research is being done to find more efficient and reliable means of starting electrical energy for orbiting satellites. Rechargeable cells offer one such means. A test program is described which has been established in order to further the evaluation of certain types of cells and to obtain performance and failure data as an aid to their continued improvement. The purpose of the program is to determine the cycling performance capabilities of packs of cells under different load and temperature conditions. The various kinds of cells tested were nickel-cadmium, silver-cadmium, and silver-zinc sealed cells. A summary of the results of the life cycling program is given in this report.
ERIC Educational Resources Information Center
Newton, Warren P.; Lefebvre, Ann; Donahue, Katrina E.; Bacon, Thomas; Dobson, Allen
2010-01-01
Introduction: Little is known regarding how to accomplish large-scale health care improvement. Our goal is to improve the quality of chronic disease care in all primary care practices throughout North Carolina. Methods: Methods for improvement include (1) common quality measures and shared data system; (2) rapid cycle improvement principles; (3)…
NASA Technical Reports Server (NTRS)
Fasching, W. A.
1979-01-01
The short core exhaust nozzle was evaluated in CF6-50 engine ground tests including performance, acoustic, and endurance tests. The test results verified the performance predictions from scale model tests. The short core exhaust nozzle provides an internal cruise sfc reduction of 0.9 percent without an increase in engine noise. The nozzle hardware successfully completed 1000 flight cycles of endurance testing without any signs of distress.
NASA Technical Reports Server (NTRS)
Nainiger, J. J.
1978-01-01
An analytical study was made of the performance of air, steam, and water-cooled gas-turbine/steam turbine combined-cycle systems with and without thermal-barrier coatings. For steam cooling, thermal barrier coatings permit an increase in the turbine inlet temperature from 1205 C (2200 F), resulting in an efficiency improvement of 1.9 percentage points. The maximum specific power improvement with thermal barriers is 32.4 percent, when the turbine inlet temperature is increased from 1425 C (2600 F) to 1675 C (3050 F) and the airfoil temperature is kept the same. For water cooling, the maximum efficiency improvement is 2.2 percentage points at a turbine inlet temperature of 1683 C (3062 F) and the maximum specific power improvement is 36.6 percent by increasing the turbine inlet temperature from 1425 C (2600 F) to 1730 C (3150 F) and keeping the airfoil temperatures the same. These improvements are greater than that obtained with combined cycles using air cooling at a turbine inlet temperature of 1205 C (2200 F). The large temperature differences across the thermal barriers at these high temperatures, however, indicate that thermal stresses may present obstacles to the use of coatings at high turbine inlet temperatures.
NASA Technical Reports Server (NTRS)
Levine, S. R.; Grisaffe, S. J.
1972-01-01
Edge and surface modifications of niobium alloys were investigated prior to coating with Si-20Cr-20Fe and slurry composition modification for performance in a 1370 C ambient pressure slow cycle test. The best coating obtained was Si-20Cr-20Mn with an average life of 63 cycles, compared to 40 for Si-20Cr-20Fe on FS-85 (100 percent improvement in weight parity life). Edge beading extended the lives of Si-20Cr-20Fe-coated Cb-752 and FS-85 to 57 and 41 cycles respectively (50 and 20 percent improvements in weight parity life respectively). W, Al2O3 and ZrO2(CaO) surface modifications altered coating crack frequency and microstructure and increased life somewhat.
Exhaustive identification of steady state cycles in large stoichiometric networks
Wright, Jeremiah; Wagner, Andreas
2008-01-01
Background Identifying cyclic pathways in chemical reaction networks is important, because such cycles may indicate in silico violation of energy conservation, or the existence of feedback in vivo. Unfortunately, our ability to identify cycles in stoichiometric networks, such as signal transduction and genome-scale metabolic networks, has been hampered by the computational complexity of the methods currently used. Results We describe a new algorithm for the identification of cycles in stoichiometric networks, and we compare its performance to two others by exhaustively identifying the cycles contained in the genome-scale metabolic networks of H. pylori, M. barkeri, E. coli, and S. cerevisiae. Our algorithm can substantially decrease both the execution time and maximum memory usage in comparison to the two previous algorithms. Conclusion The algorithm we describe improves our ability to study large, real-world, biochemical reaction networks, although additional methodological improvements are desirable. PMID:18616835
Development and testing of a high cycle life 30 A-h sealed AgO-Zn battery
NASA Technical Reports Server (NTRS)
Bogner, R. S.
1972-01-01
A two-phase program was initiated to investigate design parameters and technology to develop an improved AgO-Zn battery. The basic performance goal was 100 charge/discharge cycles (22 h/2 h) at 50 percent depth of discharge following a six-month period of charged stand at room temperature. Phase 1, cell evaluation, involved testing 70 cells in five-cell groups. The major design variables were active material ratios, electrolyte concentrations, separator systems, and negative plate shape. Phase 1 testing showed that cycle life could be improved 10 percent to 20 percent by using greater ratios of zinc to silver oxide and higher electrolyte concentrations. Wedge-shaped negatives increased cycle life by nearly 100 percent. Phase 2 battery evaluation, which was initiated before the Phase 1 results were known completely, involved evaluation of six designs as 19-cell batteries. Only one battery exceeded 100 cycles following nine months charged stand.
NASA Astrophysics Data System (ADS)
Basile, Andrew; Ferdousi, Shammi A.; Makhlooghiazad, Faezeh; Yunis, Ruhamah; Hilder, Matthias; Forsyth, Maria; Howlett, Patrick C.
2018-03-01
The plating and stripping performance of sodium metal in an ionic liquid electrolyte is improved when including water as an additive. Herein we report for the first time the trend of improved cycling behavior of Na0/+ in N-methyl-N-propylpyrrolidinium bis(fluorosulfonyl)imide with 500 ppm H2O. The addition of water to this ionic liquid electrolyte promotes the breakdown of the [FSI]- anion towards beneficial SEI formation. The benefits during plating and stripping of sodium is observed as lower total polarization during symmetrical cell cycling and decreased electrode/electrolyte interface impedance. Sodium metal surfaces after cycling with 500 ppm H2O are shown to be smooth in morphology in comparison to lower additive concentrations. The outcome of adventitious moisture benefiting Na0/+ cycling in an ionic liquid, contrary to conventional electrolytes, allows flexibility in ionic liquid electrolyte design to the benefit of battery manufacturers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kong, Long; Handa, Yusuke; Taniguchi, Izumi, E-mail: taniguchi.i.aa@m.titech.ac.jp
2016-01-15
Highlights: • A wet ball milling was conducted to synthesis S–C–V{sub 2}O{sub 5} composite electrode. • V{sub 2}O{sub 5} additive led to further improve electrochemical performance of S-cathode. • S–C–V{sub 2}O{sub 5} composite electrode exhibited a first discharge capacity of 951 mAh g{sup −1}. • The electrode (60 wt.%—S, 30 wt.%—V{sub 2}O{sub 5}, 10 wt.%—C) showed best battery performance. - Abstract: Sulfur (S)–carbon (C)–vanadium pentoxide (V{sub 2}O{sub 5}) composites were prepared by wet ball milling, and their physical and electrochemical properties were evaluated. Firstly, the effect of the carbon content of S–C composite electrodes on their physical and electrochemical propertiesmore » was investigated. The S–C composite electrode with 60 wt.% S delivers a first discharge capacity of 1077 mAh g{sup −1}. However, its capacity markedly decreases to 606 mAh g{sup −1} after 10 cycles, which corresponds to a capacity fading rate of 47 mAh g{sup −1} per cycle. To improve the electrochemical performance of the S–C composite electrode, carbon was partially replaced by V{sub 2}O{sub 5}. The S–C–V{sub 2}O{sub 5} composite electrode with a composition of 60 wt.%—S, 30 wt.%—V{sub 2}O{sub 5} and 10 wt.%—C exhibits a lower capacity fading rate of 23 mAh g{sup −1} per cycle in the first 10 cycles and better capacity retention than the S–C composite electrode over 50 cycles.« less
NASA Astrophysics Data System (ADS)
Xiang, Jiayuan; Hu, Chen; Chen, Liying; Zhang, Dong; Ding, Ping; Chen, Dong; Liu, Hao; Chen, Jian; Wu, Xianzhang; Lai, Xiaokang
2016-10-01
The effect and mechanism of Zn(II) on improving the performances of lead-acid cell with electrochemical active carbon (EAC) in negative mass is investigated. The hydrogen evolution of the cell is significantly reduced due to the deposition of Zn on carbon surface and the increased porosity of negative mass. Zn(II) additives can also improve the low-temperature and high-rate capacities of the cell with EAC in negative mass, which ascribes to the formation of Zn on lead and carbon surface that constructs a conductive bridge among the active mass. Under the co-contribution of EAC and Zn(II), the partial-state-of-charge cycle life is greatly prolonged. EAC optimizes the NAM structure and porosity to enhance the charge acceptance and retard the lead sulfate accumulation. Zn(II) additive reduces the hydrogen evolution during charge process and improves the electric conductivity of the negative electrode. The cell with 0.6 wt% EAC and 0.006 wt% ZnO in negative mass exhibits 90% reversible capacity of the initial capacity after 2100 cycles. In contrast, the cell with 0.6 wt% EAC exhibits 84% reversible capacity after 2100 cycles and the control cell with no EAC and Zn(II) exhibits less than 80% reversible capacity after 1350 cycles.
Utilization of waste heat in trucks for increased fuel economy
NASA Technical Reports Server (NTRS)
Leising, C. J.; Purohit, G. P.; Degrey, S. P.; Finegold, J. G.
1978-01-01
Improvements in fuel economy for a broad spectrum of truck engines and waste heat utilization concepts are evaluated and compared. The engines considered are the diesel, spark ignition, gas turbine, and Stirling. The waste heat utilization concepts include preheating, regeneration, turbocharging, turbocompounding, and Rankine engine compounding. Predictions were based on fuel-air cycle analyses, computer simulation, and engine test data. The results reveal that diesel driving cycle performance can be increased by 20% through increased turbocharging, turbocompounding, and Rankine engine compounding. The Rankine engine compounding provides about three times as much improvement as turbocompounding but also costs about three times as much. Performance for either is approximately doubled if applied to an adiabatic diesel.
Optimization of wave rotors for use as gas turbine engine topping cycles
NASA Technical Reports Server (NTRS)
Wilson, Jack; Paxson, Daniel E.
1995-01-01
Use of a wave rotor as a topping cycle for a gas turbine engine can improve specific power and reduce specific fuel consumption. Maximum improvement requires the wave rotor to be optimized for best performance at the mass flow of the engine. The optimization is a trade-off between losses due to friction and passage opening time, and rotational effects. An experimentally validated, one-dimensional CFD code, which includes these effects, has been used to calculate wave rotor performance, and find the optimum configuration. The technique is described, and results given for wave rotors sized for engines with sea level mass flows of 4, 26, and 400 lb/sec.
Improved, low cost inorganic-organic separators for rechargeable silver-zinc batteries
NASA Technical Reports Server (NTRS)
Sheibley, D. W.
1979-01-01
Several flexible, low-cost inorganic-organic separators with performance characteristics and cycle life equal to, or better than, the Lewis Research Center Astropower separator were developed. These new separators can be made on continuous-production equipment at about one-fourth the cost of the Astropower separator produced the same way. In test cells, these new separators demonstrate cycle life improvement, acceptable operating characteristics, and uniform current density. The various separator formulas, test cell construction, and data analysis are described.
Silicon as anode for high-energy lithium ion batteries: From molten ingot to nanoparticles
NASA Astrophysics Data System (ADS)
Leblanc, Dominic; Hovington, Pierre; Kim, Chisu; Guerfi, Abdelbast; Bélanger, Daniel; Zaghib, Karim
2015-12-01
In this work, we demonstrate that a new mechanical attrition process can be used to prepare nanosilicon powder from metallurgical grade silicon lumps. Composite Li-ion anode made from this nanometer-size powder was found to have a high reversible capacity of 2400 mAh g-1 and an improved cycling stability compared to micrometer-sized powder. It is proposed that improved battery cycling performance is ascribed to the nanoscale silicon particles which supresses the volume expansion owing to its superplasticity.
Anwer, Shoaib; Huang, Yongxin; Liu, Jia; Liu, Jiajia; Xu, Meng; Wang, Ziheng; Chen, Renjie; Zhang, Jiatao; Wu, Feng
2017-04-05
Low cycling stability and poor rate performance are two of the distinctive drawbacks of most electrode materials for sodium-ion batteries (SIBs). Here, inspired by natural flower structures, we take advantage of the three-dimensional (3D) hierarchical flower-like stable microstructures formed by two-dimensional (2D) nanosheets to solve these problems. By precise control of the hydrothermal synthesis conditions, a novel three-dimensional (3D) flower-like architecture consisting of 2D Na 2 Ti 3 O 7 nanosheets (Na-TNSs) has been successfully synthesized. The arbitrarily arranged but closely interlinked thin nanosheets in carnation-shaped 3D Na 2 Ti 3 O 7 microflowers (Na-TMFs) originate a good network of electrically conductive paths in an electrode. Thus, Na-TMFs can get electrons from all directions and be fully utilized for sodium-ion insertion and extraction reactions, which can improve sodium storage properties with enhanced rate capability and super cycling performance. Furthermore, the large specific surface area provides a high capacity, which can be ascribed to the pseudo-capacitance effect. The wettability of the electrolyte was also improved by the porous and crumpled structure. The remarkably improved cycling performance and rate capability of Na-TMFs make a captivating case for its development as an advanced anode material for SIBs.
The potential of computer-aided process engineering (CAPE) tools to enable process engineers to improve the environmental performance of both their processes and across the life cycle (from cradle-to-grave) has long been proffered. However, this use of CAPE has not been fully ach...
NASA Technical Reports Server (NTRS)
Marte, J. E.; Bryant, J. A.; Livingston, R.
1983-01-01
Dynamometer performance of a South Coast Technology electric conversion of a Volkswagen (VW) Rabbit designated SCT-8 was tested. The SCT-8 vehicle was fitted with a transistorized chopper in the motor armature circuit to supplement the standard motor speed control via field weakening. The armature chopper allowed speed control below the motor base speed. This low speed control was intended to reduce energy loss at idle during stop-and-go traffic; to eliminate the need for using the clutch below base motor speed; and to improve the drivability. Test results indicate an improvement of about 3.5% in battery energy economy for the SAE J227a-D driving cycle and 6% for the C-cycle with only a minor reduction in acceleration performance. A further reduction of about 6% would be possible if provision were made for shutting down field power during the idle phases of the driving cycles. Drivability of the vehicle equipped with the armature chopper was significantly improved compared with the standard SCT Electric Rabbit.
NASA Technical Reports Server (NTRS)
Fasching, W. A.
1980-01-01
The improved single shank high pressure turbine design was evaluated in component tests consisting of performance, heat transfer and mechanical tests, and in core engine tests. The instrumented core engine test verified the thermal, mechanical, and aeromechanical characteristics of the improved turbine design. An endurance test subjected the improved single shank turbine to 1000 simulated flight cycles, the equivalent of approximately 3000 hours of typical airline service. Initial back-to-back engine tests demonstrated an improvement in cruise sfc of 1.3% and a reduction in exhaust gas temperature of 10 C. An additional improvement of 0.3% in cruise sfc and 6 C in EGT is projected for long service engines.
Rechargeable Zinc Alkaline Anodes for Long-Cycle Energy Storage
Turney, Damon E.; Gallaway, Joshua W.; Yadav, Gautam G.; ...
2017-05-03
Zinc alkaline anodes command significant share of consumer battery markets and are a key technology for the emerging grid-scale battery market. Improved understanding of this electrode is required for long-cycle deployments at kWh and MWh scale due to strict requirements on performance, cost, and safety. For this article, we give a modern literature survey of zinc alkaline anodes with levelized performance metrics and also present an experimental assessment of leading formulations. Long-cycle materials characterization, performance metrics, and failure analysis are reported for over 25 unique anode formulations with up to 1500 cycles and ~1.5 years of shelf life per test.more » Statistical repeatability of these measurements is made for a baseline design (fewest additives) via 15 duplicates. Baseline design capacity density is 38 mAh per mL of anode volume, and lifetime throughput is 72 Ah per mL of anode volume. We then report identical measurements for anodes with improved material properties via additives and other perturbations, some of which achieve capacity density over 192 mAh per mL of anode volume and lifetime throughput of 190 Ah per mL of anode volume. Novel in operando X-ray microscopy of a cycling zinc paste anode reveals the formation of a nanoscale zinc material that cycles electrochemically and replaces the original anode structure over long-cycle life. Ex situ elemental mapping and other materials characterization suggest that the key physical processes are hydrogen evolution reaction (HER), growth of zinc oxide nanoscale material, concentration deficits of OH – and ZnOH 4 2–, and electrodeposition of Zn growths outside and through separator membranes.« less
Productivity improvement through cycle time analysis
NASA Astrophysics Data System (ADS)
Bonal, Javier; Rios, Luis; Ortega, Carlos; Aparicio, Santiago; Fernandez, Manuel; Rosendo, Maria; Sanchez, Alejandro; Malvar, Sergio
1996-09-01
A cycle time (CT) reduction methodology has been developed in the Lucent Technology facility (former AT&T) in Madrid, Spain. It is based on a comparison of the contribution of each process step in each technology with a target generated by a cycle time model. These targeted cycle times are obtained using capacity data of the machines processing those steps, queuing theory and theory of constrains (TOC) principles (buffers to protect bottleneck and low cycle time/inventory everywhere else). Overall efficiency equipment (OEE) like analysis is done in the machine groups with major differences between their target cycle time and real values. Comparisons between the current value of the parameters that command their capacity (process times, availability, idles, reworks, etc.) and the engineering standards are done to detect the cause of exceeding their contribution to the cycle time. Several friendly and graphical tools have been developed to track and analyze those capacity parameters. Specially important have showed to be two tools: ASAP (analysis of scheduling, arrivals and performance) and performer which analyzes interrelation problems among machines procedures and direct labor. The performer is designed for a detailed and daily analysis of an isolate machine. The extensive use of this tool by the whole labor force has demonstrated impressive results in the elimination of multiple small inefficiencies with a direct positive implications on OEE. As for ASAP, it shows the lot in process/queue for different machines at the same time. ASAP is a powerful tool to analyze the product flow management and the assigned capacity for interdependent operations like the cleaning and the oxidation/diffusion. Additional tools have been developed to track, analyze and improve the process times and the availability.
Rechargeable Zinc Alkaline Anodes for Long-Cycle Energy Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turney, Damon E.; Gallaway, Joshua W.; Yadav, Gautam G.
Zinc alkaline anodes command significant share of consumer battery markets and are a key technology for the emerging grid-scale battery market. Improved understanding of this electrode is required for long-cycle deployments at kWh and MWh scale due to strict requirements on performance, cost, and safety. For this article, we give a modern literature survey of zinc alkaline anodes with levelized performance metrics and also present an experimental assessment of leading formulations. Long-cycle materials characterization, performance metrics, and failure analysis are reported for over 25 unique anode formulations with up to 1500 cycles and ~1.5 years of shelf life per test.more » Statistical repeatability of these measurements is made for a baseline design (fewest additives) via 15 duplicates. Baseline design capacity density is 38 mAh per mL of anode volume, and lifetime throughput is 72 Ah per mL of anode volume. We then report identical measurements for anodes with improved material properties via additives and other perturbations, some of which achieve capacity density over 192 mAh per mL of anode volume and lifetime throughput of 190 Ah per mL of anode volume. Novel in operando X-ray microscopy of a cycling zinc paste anode reveals the formation of a nanoscale zinc material that cycles electrochemically and replaces the original anode structure over long-cycle life. Ex situ elemental mapping and other materials characterization suggest that the key physical processes are hydrogen evolution reaction (HER), growth of zinc oxide nanoscale material, concentration deficits of OH – and ZnOH 4 2–, and electrodeposition of Zn growths outside and through separator membranes.« less
2012-01-01
The use of herbs as ergogenic aids in exercise and sport is not novel. Ginseng, caffeine, ma huang (also called 'Chinese ephedra'), ephedrine and a combination of both caffeine and ephedrine are the most popular herbs used in exercise and sports. It is believed that these herbs have an ergogenic effect and thus help to improve physical performance. Numerous studies have been conducted to investigate the effects of these herbs on exercise performance. Recently, researchers have also investigated the effects of Eurycoma longifolia Jack on endurance cycling and running performance. These investigators have reported no significant improvement in either cycling or running endurance after supplementation with this herb. As the number of studies in this area is still small, more studies should be conducted to evaluate and substantiate the effects of this herb on sports and exercise performance. For instance, future research on any herbs should take the following factors into consideration: dosage, supplementation period and a larger sample size. PMID:22738233
Colloquium on Large Scale Improvement: Implications for AISI
ERIC Educational Resources Information Center
McEwen, Nelly, Ed.
2008-01-01
The Alberta Initiative for School Improvement (AISI) is a province-wide partnership program whose goal is to improve student learning and performance by fostering initiatives that reflect the unique needs and circumstances of each school authority. It is currently ending its third cycle and ninth year of implementation. "The Colloquium on…
Stein, Erica B; Liu, Peter S; Kazerooni, Ella A; Barber, Karen; Davenport, Matthew S
2016-12-01
The objective of our study was to reduce variation in image quality of orthogonal reformatted images generated from long-z-axis CT angiography (CTA) studies of the upper and lower extremities. Upper and lower extremity CTA studies were targeted at a single health care system. A correctly performed CTA examination was defined as one that met the following three criteria: Sagittal and coronal reformats were obtained, a high-resolution matrix greater than 512 × 512 was used, and reformatted images were available in a distance-measurable format. Baseline data were collected from February 1, 2014, through September 30, 2014. Corrective actions were implemented during three consecutive plan-do-check-act (PDCA) cycles from October 1, 2014, through July 31, 2015, that addressed human, technical, and systematic variations. A 3-month maintenance period followed in which no intervention was performed. Longitudinal data were analyzed monthly using a statistical process control chart (p-chart). The total number of long-z-axis extremity CTA studies analyzed was as follows: 351 CTA studies were analyzed at baseline, 94 at the first PDCA cycle, 92 at the second PDCA cycle, 114 at the third PDCA cycle, and 138 during the maintenance period. The monthly rate of correctly performed studies ranged from 7% to 51% (mean, 38% ± 13% [SD]) during the baseline period, 32-59% (mean, 46% ± 14%) during the first PDCA cycle, 40-81% (mean, 61% ± 21%) during the second PDCA cycle, and 80-82% (mean, 81% ± 0.9%) during the third PDCA cycle. The monthly rate improved to 90-91% (mean, 91% ± 0.5%) during the maintenance period. The upper and lower control limits of the p-chart were upshifted after the second and third PDCA cycles. Correcting systematic and technical variations led to the greatest improvements in reformat accuracy. Obtaining consistently and correctly reformatted images from long-z-axis CTA studies is achievable using iterative PDCA cycles.
Equilibrium cycle pin by pin transport depletion calculations with DeCART
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kochunas, B.; Downar, T.; Taiwo, T.
As the Advanced Fuel Cycle Initiative (AFCI) program has matured it has become more important to utilize more advanced simulation methods. The work reported here was performed as part of the AFCI fellowship program to develop and demonstrate the capability of performing high fidelity equilibrium cycle calculations. As part of the work here, a new multi-cycle analysis capability was implemented in the DeCART code which included modifying the depletion modules to perform nuclide decay calculations, implementing an assembly shuffling pattern description, and modifying iteration schemes. During the work, stability issues were uncovered with respect to converging simultaneously the neutron flux,more » isotopics, and fluid density and temperature distributions in 3-D. Relaxation factors were implemented which considerably improved the stability of the convergence. To demonstrate the capability two core designs were utilized, a reference UOX core and a CORAIL core. Full core equilibrium cycle calculations were performed on both cores and the discharge isotopics were compared. From this comparison it was noted that the improved modeling capability was not drastically different in its prediction of the discharge isotopics when compared to 2-D single assembly or 2-D core models. For fissile isotopes such as U-235, Pu-239, and Pu-241 the relative differences were 1.91%, 1.88%, and 0.59%), respectively. While this difference may not seem large it translates to mass differences on the order of tens of grams per assembly, which may be significant for the purposes of accounting of special nuclear material. (authors)« less
Alameddine, Mohamad; Mufarrij, Afif; Saliba, Miriam; Mourad, Yara; Jabbour, Rima; Hitti, Eveline
2015-02-27
Peer evaluation is increasingly used as a method to assess physicians' interpersonal and communication skills. We report on experience with soliciting registered nurses' feedback on physicians' non-clinical performance in the ED of a large academic medical center in Lebanon. We utilized a secondary analysis of a de-identified database of ED nurses' assessment of physicians' non-clinical performance coupled with an evaluation of interventions carried out as a result of this evaluation. The database was compiled as part of quality/performance improvement initiatives using a cross-sectional design to survey registered nurses working at the ED. The survey instrument included open ended and closed ended questions assessing physicians' communication, professionalism and leadership skills. Three episodes of evaluation were carried out over an 18 month period. Physicians were provided with a communication training carried out after the first cycle of evaluation and a detailed feedback on their assessment by nurses after each evaluation cycle. A paired t-test was carried out to compare mean evaluation scores between the three cycles of evaluation. Thematic analysis of nurses' qualitative comments was carried out. A statistically significant increase in the averages of skills was observed between the first and second evaluations, followed by a significant decrease in the averages of the three skills between the second and third evaluations. Personalized feedback to ED physicians and communication training initially contributed to a significant positive impact on improving ED physicians' non-clinical skills as perceived by the ED nurses. Yet, gains achieved were lost upon reaching the third cycle of evaluation. However, the thematic analysis of the nurses' qualitative responses portrays a decrease in concerns across the various dimensions of non-clinical performance. Nurses' evaluation of the non-clinical performance of physicians has the potential of improving communication, professionalism and leadership skills amongst physicians. For improvement to be realized in a sustainable manner, such programs may need to be offered in a staged and incremental manner over a long period of time with proper dedication of resources and timely monitoring and evaluation of outcomes. Department directors need to be trained on providing peer evaluation feedback in a constructive manner.
Crisafulli, Daniel L; Buddhadev, Harsh H; Brilla, Lorrie R; Chalmers, Gordon R; Suprak, David N; San Juan, Jun G
2018-01-01
Creatine supplementation is recommended as an ergogenic aid to improve repeated sprint cycling performance. Furthermore, creatine uptake is increased in the presence of electrolytes. Prior research examining the effect of a creatine-electrolyte (CE) supplement on repeated sprint cycling performance, however, did not show post-supplementation improvement. The purpose of this double blind randomized control study was to investigate the effect of a six-week CE supplementation intervention on overall and repeated peak and mean power output during repeated cycling sprints with recovery periods of 2 min between sprints. Peak and mean power generated by 23 male recreational cyclists (CE group: n = 12; 24.0 ± 4.2 years; placebo (P) group: n = 11; 23.3 ± 3.1 years) were measured on a Velotron ergometer as they completed five 15-s cycling sprints, with 2 min of recovery between sprints, pre- and post-supplementation. Mixed-model ANOVAs were used for statistical analyses. A supplement-time interaction showed a 4% increase in overall peak power (pre: 734 ± 75 W; post: 765 ± 71 W; p = 0.040; η p 2 = 0.187) and a 5% increase in overall mean power (pre: 586 ± 72 W; post: 615 ± 74 W; p = 0.019; η p 2 = 0.234) from pre- to post-supplementation for the CE group. For the P group, no differences were observed in overall peak (pre: 768 ± 95 W; post: 772 ± 108 W; p = 0.735) and overall mean power (pre: 638 ± 77 W; post: 643 ± 92 W; p = 0.435) from pre- to post-testing. For repeated sprint analysis, peak (pre: 737 ± 88 W; post: 767 ± 92 W; p = 0.002; η p 2 = 0.380) and mean (pre: 650 ± 92 W; post: 694 ± 87 W; p < 0.001; η p 2 = 0.578) power output were significantly increased only in the first sprint effort in CE group from pre- to post-supplementation testing. For the P group, no differences were observed for repeated sprint performance. A CE supplement improves overall and repeated short duration sprint cycling performance when sprints are interspersed with adequate recovery periods.
Strategies for improving performance in long duration events: Olympic distance triathlon.
Hausswirth, Christophe; Brisswalter, Jeanick
2008-01-01
This review focuses on strategic aspects that may affect performance in a long-duration Olympic event, the Olympic distance triathlon. Given the variety of races during the Olympic Games triathlon, strategic aspects include improving technological features as well as energetics factors affecting overall triathlon performance. During the last decade, many studies have attempted to identify factors reducing the metabolic load associated (or not) with the development of fatigue process by analysing the relationship between metabolic and biomechanical factors with exercise duration. To date, a consensus exists about the benefit of adopting a drafting position during the swimming or the cycling part of the triathlon. Other potential strategic factors, such as the production of power output or the selection of cadence during the cycling or the running leg, are likely to affect the overall triathlon performance. Within this approach, pacing strategies are observed by elite athletes who swim or cycle in a sheltered position, inducing several changes of pace, intensity or stochastic shifts in the amplitude of the physiological responses. The analysis of these parameters appears to arouse some experimental and practical interest from researchers and coachers, especially for long-distance Olympic events.
Performance improvement of robots using a learning control scheme
NASA Technical Reports Server (NTRS)
Krishna, Ramuhalli; Chiang, Pen-Tai; Yang, Jackson C. S.
1987-01-01
Many applications of robots require that the same task be repeated a number of times. In such applications, the errors associated with one cycle are also repeated every cycle of the operation. An off-line learning control scheme is used here to modify the command function which would result in smaller errors in the next operation. The learning scheme is based on a knowledge of the errors and error rates associated with each cycle. Necessary conditions for the iterative scheme to converge to zero errors are derived analytically considering a second order servosystem model. Computer simulations show that the errors are reduced at a faster rate if the error rate is included in the iteration scheme. The results also indicate that the scheme may increase the magnitude of errors if the rate information is not included in the iteration scheme. Modification of the command input using a phase and gain adjustment is also proposed to reduce the errors with one attempt. The scheme is then applied to a computer model of a robot system similar to PUMA 560. Improved performance of the robot is shown by considering various cases of trajectory tracing. The scheme can be successfully used to improve the performance of actual robots within the limitations of the repeatability and noise characteristics of the robot.
Rustad, Per I.; Kolnes, Kristoffer J.; Sollie, Ove; Franch, Jesper; Ivy, John L.; Daniel, Hannelore; Jensen, Jørgen
2016-01-01
Intake of protein immediately after exercise stimulates protein synthesis but improved recovery of performance is not consistently observed. The primary aim of the present study was to compare performance 18 h after exhaustive cycling in a randomized diet-controlled study (175 kJ·kg-1 during 18 h) when subjects were supplemented with protein plus carbohydrate or carbohydrate only in a 2-h window starting immediately after exhaustive cycling. The second aim was to investigate the effect of no nutrition during the first 2 h and low total energy intake (113 kJ·kg-1 during 18 h) on performance when protein intake was similar. Eight endurance-trained subjects cycled at 237±6 Watt (~72% VO2max) until exhaustion (TTE) on three occasions, and supplemented with 1.2 g carbohydrate·kg-1·h-1 (CHO), 0.8 g carbohydrate + 0.4 g protein·kg-1·h-1 (CHO+PRO) or placebo without energy (PLA). Intake of CHO+PROT increased plasma glucose, insulin, and branch chained amino acids, whereas CHO only increased glucose and insulin. Eighteen hours later, subjects performed another TTE at 237±6 Watt. TTE was increased after intake of CHO+PROT compared to CHO (63.5±4.4 vs 49.8±5.4 min; p<0.05). PLA reduced TTE to 42.8±5.1 min (p<0.05 vs CHO). Nitrogen balance was positive in CHO+PROT, and negative in CHO and PLA. In conclusion, performance was higher 18 h after exhaustive cycling with intake of CHO+PROT compared to an isocaloric amount of carbohydrate during the first 2 h post exercise. Intake of a similar amount of protein but less carbohydrate during the 18 h recovery period reduced performance. PMID:27078151
Rankin, Kristin M.; Gavin, Loretta; Moran, John W.; Kroelinger, Charlan D.; Vladutiu, Catherine J.; Goodman, David A.; Sappenfield, William M.
2018-01-01
Purpose In recognition of the importance of performance measurement and MCH epidemiology leadership to quality improvement (QI) efforts, a plenary session dedicated to this topic was presented at the 2014 CityMatCH Leadership and MCH Epidemiology Conference. This paper summarizes the session and provides two applications of performance measurement to QI in MCH. Description Performance measures addressing processes of care are ubiquitous in the current health system landscape and the MCH community is increasingly applying QI processes, such as Plan-Do-Study-Act (PDSA) cycles, to improve the effectiveness and efficiency of systems impacting MCH populations. QI is maximally effective when well-defined performance measures are used to monitor change. Assessment MCH epidemiologists provide leadership to QI initiatives by identifying population-based outcomes that would benefit from QI, defining and implementing performance measures, assessing and improving data quality and timeliness, reporting variability in measures throughout PDSA cycles, evaluating QI initiative impact, and translating findings to stakeholders. MCH epidemiologists can also ensure that QI initiatives are aligned with MCH priorities at the local, state and federal levels. Two examples of this work, one highlighting use of a contraceptive service performance measure and another describing QI for peripartum hemorrhage prevention, demonstrate MCH epidemiologists’ contributions throughout. Challenges remain in applying QI to complex community and systems-level interventions, including those aimed at improving access to quality care. Conclusion MCH epidemiologists provide leadership to QI initiatives by ensuring they are data-informed and supportive of a common MCH agenda, thereby optimizing the potential to improve MCH outcomes. PMID:27423235
Rankin, Kristin M; Gavin, Loretta; Moran, John W; Kroelinger, Charlan D; Vladutiu, Catherine J; Goodman, David A; Sappenfield, William M
2016-11-01
Purpose In recognition of the importance of performance measurement and MCH epidemiology leadership to quality improvement (QI) efforts, a plenary session dedicated to this topic was presented at the 2014 CityMatCH Leadership and MCH Epidemiology Conference. This paper summarizes the session and provides two applications of performance measurement to QI in MCH. Description Performance measures addressing processes of care are ubiquitous in the current health system landscape and the MCH community is increasingly applying QI processes, such as Plan-Do-Study-Act (PDSA) cycles, to improve the effectiveness and efficiency of systems impacting MCH populations. QI is maximally effective when well-defined performance measures are used to monitor change. Assessment MCH epidemiologists provide leadership to QI initiatives by identifying population-based outcomes that would benefit from QI, defining and implementing performance measures, assessing and improving data quality and timeliness, reporting variability in measures throughout PDSA cycles, evaluating QI initiative impact, and translating findings to stakeholders. MCH epidemiologists can also ensure that QI initiatives are aligned with MCH priorities at the local, state and federal levels. Two examples of this work, one highlighting use of a contraceptive service performance measure and another describing QI for peripartum hemorrhage prevention, demonstrate MCH epidemiologists' contributions throughout. Challenges remain in applying QI to complex community and systems-level interventions, including those aimed at improving access to quality care. Conclusion MCH epidemiologists provide leadership to QI initiatives by ensuring they are data-informed and supportive of a common MCH agenda, thereby optimizing the potential to improve MCH outcomes.
Training Prescription Guided by Heart Rate Variability in Cycling.
Javaloyes, Alejandro; Sarabia, Jose Manuel; Lamberts, Robert Patrick; Moya-Ramon, Manuel
2018-05-29
Road cycling is a sport with extreme physiological demands. Therefore, there is a need to find new strategies to improve performance. Heart rate variability (HRV) has been suggested as an effective alternative for prescribing training load against predefined training programs. The purpose of this study is to examine the effect of training prescription based on HRV in road cycling performance. Seventeen well-trained cyclists participated in this study. After an initial evaluation week (EW), cyclists performed 4 baseline weeks (BW) of standardized training to establish their resting HRV. Then, cyclists were divided into two groups, a HRV-guided group (HRV-G) and a traditional periodization group (TRAD) and they carried out 8 training weeks (TW). Cyclists performed two EW, after and before TW. During the EW, cyclists performed: (1) a graded exercise test to assess VO2max, peak power output (PPO) and ventilatory thresholds with their corresponding power output (VT1, VT2, WVT1, and WVT2, respectively) and (2) a 40-min simulated time-trial. HRV-G improved PPO (5.1 ± 4.5 %; p = 0.024), WVT2 (13.9 ± 8.8 %; p = 0.004) and 40TT (7.3 ± 4.5 %; p = 0.005). VO2max and WVT1 remained similar. TRAD did not improve significantly after TW. There were no differences between groups. However, magnitude-based inference analysis showed likely beneficial and possibly beneficial effects for HRV-G instead of TRAD in 40TT and PPO, respectively. Daily training prescription based on HRV could result in a better performance enhancement than a traditional periodization in well-trained cyclists.
Applied physiology of triathlon.
O'Toole, M L; Douglas, P S
1995-04-01
The triathlon is a 3-event endurance sport in which athletes compete sequentially in swimming, cycling and running. The primary determinant of success is the ability to sustain a high rate of energy expenditure for prolonged periods of time. Exercise training-induced physiological adaptations in virtually all systems of the body allow the athlete to accomplish this. Aerobic capacity (measured as maximal oxygen uptake, VO2max), economy of motion (submaximal VO2) and fractional utilisation of maximal capacity (%VO2max) reflect the integrated responses of these physiological adaptations. Numerous studies have reported relatively high mean VO2max values for various groups of triathletes that are comparable to those reported for athletes in single-event endurance sports and clearly above those reported for untrained individuals. In shorter distance triathlons and in studies using recreational (rather than elite) triathletes, VO2max is related to performance in the corresponding event of the triathlon (e.g. tethered swimming VO2max with swim time). In longer events and with more elite triathletes, VO2max correlates less well with performance. The physiological adaptations that correspond to and facilitate improved VO2max occur centrally in the cardiovascular system, centred on increased maximal cardiac output, and peripherally in the metabolic systems, centred around increased arterio-venous O2 (a-v O2) difference. While a high VO2max in individuals is clearly of importance to triathlon performance, energy output must be sustained for long periods of time, making economy of motion also very important. Studies suggests that competitive swimmers have better swimming economy than triathletes. However, since many triathletes have previously been competitive swimmers this finding is questionable. The finding suggests that triathletes from nonswimming backgrounds would benefit from improving swimming technique rather than concentrating training workouts solely on distance. In cycling and running, comparison studies have not been done. Economy of motion in swimming, cycling and running have all been found to be correlated with comparable event performance. Training to improve swimming economy can be done without prior exercise, but training to improve swimming economy can be done without prior exercise, but training to improve cycling and running economy should take the multimode nature of a triathlon into consideration. That is, swimming should precede cycling economy training, and cycling should precede running economy training. Cardiovascular, metabolic and neuromuscular adaptations are the main physiological correlates of improved movement economy. Since exercise-induced stress on most physiological systems is based on relative, rather than absolute, exercise intensity, training and racing intensities are frequently quantified as a percentage of maximal capacity of %VO2max.(ABSTRACT TRUNCATED AT 400 WORDS)
NASA Astrophysics Data System (ADS)
Hwang, Keebum; Sohn, Hiesang; Yoon, Songhun
2018-02-01
Mesostructured niobium (Nb)-doped TiO2-carbon (Nb-TiO2-C) composites are synthesized by a hydrothermal process for application as anode materials in Li-ion batteries. The composites have a hierarchical porous structure with the Nb-TiO2 nanoparticles homogenously distributed throughout the porous carbon matrix. The Nb content is controlled (0-10 wt%) to investigate its effect on the physico-chemical properties and electrochemical performance of the composite. While the crystalline/surface structure varied with the addition of Nb (d-spacing of TiO2: 0.34-0.36 nm), the morphology of the composite remained unaffected. The electrochemical performance (cycle stability and rate capability) of the Nb-TiO2-C composite anode with 1 wt% Nb doping improved significantly. First, a full cut-off potential (0-2.5 V vs. Li/Li+) of Nb-doped composite anode (1 wt%) provides a higher energy utilization than that of the un-doped TiO2-C anode. Second, Nb-TiO2-C composite anode (1 wt%) exhibits an excellent long-term cycle stability (100% capacity retention, 297 mAh/g at 0.5 C after 100 cycles and 221 mAh/g at 2 C after 500 cycles) and improved rate-capability (192 mAh/g at 5 C), respectively (1 C: 150 mA/g). The superior electrochemical performance of Nb-TiO2-C (1 wt%) could be attributed to the synergistic effect of improved electronic conductivity induced by optimal Nb doping (1 wt%) and lithium-ion penetration (high diffusion kinetics) through unique pore structures.
Segmentation and classification of cell cycle phases in fluorescence imaging.
Ersoy, Ilker; Bunyak, Filiz; Chagin, Vadim; Cardoso, M Christina; Palaniappan, Kannappan
2009-01-01
Current chemical biology methods for studying spatiotemporal correlation between biochemical networks and cell cycle phase progression in live-cells typically use fluorescence-based imaging of fusion proteins. Stable cell lines expressing fluorescently tagged protein GFP-PCNA produce rich, dynamically varying sub-cellular foci patterns characterizing the cell cycle phases, including the progress during the S-phase. Variable fluorescence patterns, drastic changes in SNR, shape and position changes and abundance of touching cells require sophisticated algorithms for reliable automatic segmentation and cell cycle classification. We extend the recently proposed graph partitioning active contours (GPAC) for fluorescence-based nucleus segmentation using regional density functions and dramatically improve its efficiency, making it scalable for high content microscopy imaging. We utilize surface shape properties of GFP-PCNA intensity field to obtain descriptors of foci patterns and perform automated cell cycle phase classification, and give quantitative performance by comparing our results to manually labeled data.
Wu, Xiao; Yao, Shanshan; Hou, Jinli; Jing, Maoxiang; Qian, Xinye; Shen, Xiangqian; Xiang, Jun; Xi, Xiaoming
2017-04-01
Conventional lithium-sulfur batteries suffer from severe capacity fade, which is induced by low electron conductivity and high dissolution of intermediated polysulfides. Recent studies have shown the metal (Pt, Au, Ni) as electrocatalyst of lithium polysulfides and improved the performance for lithium sulfur batteries. In this work, we present the nickel coated multi-walled carbon nanotubes (Ni-MWNTs) as additive materials for elemental sulfur positive electrodes for lithium-sulfur rechargeable batteries. Compared with MWNTs, the obtained Ni-MWNTs/sulfur composite cathode demonstrate a reversible specific capacity approaching 545 mAh after 200 cycles at a rate of 0.5C as well as improved cycling stability and excellent rate capacity. The improved electrochemical performance can be attributed to the fact the MWNTs shows a vital role on polysulfides adsorption and nickel has a catalytic effect on the redox reactions during charge–discharge process. Meanwhile, the Ni-MWNTs is a good electric conductor for sulfur cathode.
Engine Seal Technology Requirements to Meet NASA's Advanced Subsonic Technology Program Goals
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Hendricks, Robert C.
1994-01-01
Cycle studies have shown the benefits of increasing engine pressure ratios and cycle temperatures to decrease engine weight and improve performance of commercial turbine engines. NASA is working with industry to define technology requirements of advanced engines and engine technology to meet the goals of NASA's Advanced Subsonic Technology Initiative. As engine operating conditions become more severe and customers demand lower operating costs, NASA and engine manufacturers are investigating methods of improving engine efficiency and reducing operating costs. A number of new technologies are being examined that will allow next generation engines to operate at higher pressures and temperatures. Improving seal performance - reducing leakage and increasing service life while operating under more demanding conditions - will play an important role in meeting overall program goals of reducing specific fuel consumption and ultimately reducing direct operating costs. This paper provides an overview of the Advanced Subsonic Technology program goals, discusses the motivation for advanced seal development, and highlights seal technology requirements to meet future engine performance goals.
Carbon Disulfide Cosolvent Electrolytes for High-Performance Lithium Sulfur Batteries.
Gu, Sui; Wen, Zhaoyin; Qian, Rong; Jin, Jun; Wang, Qingsong; Wu, Meifen; Zhuo, Shangjun
2016-12-21
Development of lithium sulfur (Li-S) batteries with high Coulombic efficiency and long cycle stability remains challenging due to the dissolution and shuttle of polysulfides in electrolyte. Here, a novel additive, carbon disulfide (CS 2 ), to the organic electrolyte is reported to improve the cycling performance of Li-S batteries. The cells with the CS 2 -additive electrolyte exhibit high Coulombic efficiency and long cycle stability, showing average Coulombic efficiency >99% and a capacity retention of 88% over the entire 300 cycles. The function of the CS 2 additive is 2-fold: (1) it inhibits the migration of long-chain polysulfides to the anode by forming complexes with polysulfides and (2) it passivates electrode surfaces by inducing the protective coatings on both the anode and the cathode.
Li, Jianjiang; Chen, Shuai; Zhu, Xiaoyi; She, Xilin; Liu, Tongchao; Zhang, Huawei; Komarneni, Sridhar; Yang, Dongjiang; Yao, Xiangdong
2017-12-01
A biomass-templated pathway is developed for scalable synthesis of NiCo 2 O 4 @carbon aerogel electrodes for supercapacitors, where NiCo 2 O 4 hollow nanoparticles with an average outer diameter of 30-40 nm are conjoined by graphitic carbon forming a 3D aerogel structure. This kind of NiCo 2 O 4 aerogel structure shows large specific surface area (167.8 m 2 g -1 ), high specific capacitance (903.2 F g -1 at a current density of 1 A g -1 ), outstanding rate performance (96.2% capacity retention from 1 to 10 A g -1 ), and excellent cycling stability (nearly without capacitance loss after 3000 cycles at 10 A g -1 ). The unique structure of the 3D hollow aerogel synergistically contributes to the high performance. For instance, the 3D interconnected porous structure of the aerogel is beneficial for electrolyte ion diffusion and for shortening the electron transport pathways, and thus can improve the rate performance. The conductive carbon joint greatly enhances the specific capacity, and the hollow structure prohibits the volume changes during the charge-discharge process to significantly improve the cycling stability. This work represents a giant step toward the preparation of high-performance commercial supercapacitors.
Li, Jianjiang; Chen, Shuai; Zhu, Xiaoyi; She, Xilin; Liu, Tongchao; Zhang, Huawei; Komarneni, Sridhar
2017-01-01
Abstract A biomass‐templated pathway is developed for scalable synthesis of NiCo2O4@carbon aerogel electrodes for supercapacitors, where NiCo2O4 hollow nanoparticles with an average outer diameter of 30–40 nm are conjoined by graphitic carbon forming a 3D aerogel structure. This kind of NiCo2O4 aerogel structure shows large specific surface area (167.8 m2 g−1), high specific capacitance (903.2 F g−1 at a current density of 1 A g−1), outstanding rate performance (96.2% capacity retention from 1 to 10 A g−1), and excellent cycling stability (nearly without capacitance loss after 3000 cycles at 10 A g−1). The unique structure of the 3D hollow aerogel synergistically contributes to the high performance. For instance, the 3D interconnected porous structure of the aerogel is beneficial for electrolyte ion diffusion and for shortening the electron transport pathways, and thus can improve the rate performance. The conductive carbon joint greatly enhances the specific capacity, and the hollow structure prohibits the volume changes during the charge–discharge process to significantly improve the cycling stability. This work represents a giant step toward the preparation of high‐performance commercial supercapacitors. PMID:29270344
NASA Astrophysics Data System (ADS)
Trask, Stephen E.; Li, Yan; Kubal, Joseph J.; Bettge, Martin; Polzin, Bryant J.; Zhu, Ye; Jansen, Andrew N.; Abraham, Daniel P.
2014-08-01
In this article we describe efforts to improve performance and cycle life of cells containing Li1.2Ni0.15Mn0.55Co0.1O2-based positive and graphite-based negative electrodes. Initial work to identify high-performing materials, compositions, fabrication variables, and cycling conditions is conducted in coin cells. The resulting information is then used for the preparation of double-sided electrodes, assembly of pouch cells, and electrochemical testing. We report the cycling performance of cells with electrodes prepared under various conditions. Our data indicate that cells with positive electrodes containing 92 wt.% Li1.2Ni0.15Mn0.55Co0.1O2, 4 wt.% carbons (no graphite), and 4 wt.% PVdF (92-4-4) show ∼20% capacity fade after 1000 cycles in the 2.5-4.4 V range, significantly better than our baseline cells that show the same fade after only 450 cycles. Our analyses indicate that the major contributors to cell energy fade are capacity loss and impedance rise. Therefore incorporating approaches that minimize capacity fade and impedance rise, such as electrode coatings and electrolyte additives, can significantly enhance calendar and cycle life of this promising cell chemistry.
NASA Astrophysics Data System (ADS)
Lian, Qingwang; Zhou, Gang; Liu, Jiatu; Wu, Chen; Wei, Weifeng; Chen, Libao; Li, Chengchao
2017-10-01
Here, we report a new enhanced extrinsic pseudocapacitve Li-ion storage mechanism via lithiation-induced structural optimization strategy. The flower-like C@SnS and bulk SnS exhibit initial capacity decay and subsequent increase of capacity on cycling. After a long-term lithiation/delithiation process, flower-like C@SnS and bulk SnS exhibit improved rate performance and reversible capacity in comparison with those of initial state. Moreover, a high capacity of 530 mAh g-1 is still remained even after 1550 cycles at a high current density of 5.0 A g-1 for flower-like C@SnS after pre-lithiation of 350 cycles. According to the comprehensive analysis of structural evolution and electrochemical performance, it demonstrates that SnS electrodes experience crystal size reduction and further amorphization on cycling, which enhances the reversibility of conversion reaction for SnS, leading to increasing capacity. On the other hand, surface-dominated extrinsic pseudocapacitive contribution results in enhanced rate performance because electrodes expose a large fraction of Li+ sites on surface or near-surface region with structural optimization on cycling. This study reveals that extrinsic pseudocapacitance of SnS can be stimulated via lithiation-induced structural optimization, which gives rise to high-rate and long-lived performances.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trask, Stephen E.; Li, Yan; Kubal, Joseph J.
2014-08-01
In this article we describe efforts to improve performance and cycle life of cells containing Li1.2Ni0.15Mn0.55Co0.1O2-based positive and graphite-based negative electrodes. Initial work to identify high-performing materials, compositions, fabrication variables, and cycling conditions is conducted in coin cells. The resulting information is then used for the preparation of double-sided electrodes, assembly of pouch cells, and electrochemical testing. We report the cycling performance of cells with electrodes prepared under various conditions. Our data indicate that cells with positive electrodes containing 92 wt% Li1.2Ni0.15Mn0.55Co0.1O2, 4 wt% carbons (no graphite), and 4 wt% PVdF (92-4-4) show ~20% capacity fade after 1000 cycles inmore » the 2.5-4.4V range, significantly better than our baseline cells that show the same fade after only 450 cycles. Our analyses indicate that the major contributors to cell energy fade are capacity loss and impedance rise. Therefore incorporating approaches that minimize capacity fade and impedance rise, such as electrode coatings and electrolyte additives, can significantly enhance calendar and cycle life of this promising cell chemistry.« less
NASA Astrophysics Data System (ADS)
Zhang, Jian; Luan, Yanping; Lyu, Zhiyang; Wang, Liangjun; Xu, Leilei; Yuan, Kaidi; Pan, Feng; Lai, Min; Liu, Zhaolin; Chen, Wei
2015-09-01
A rechargeable lithium-oxygen (Li-O2) battery with a remarkably high theoretical energy storage capacity has attracted enormous research attention. However, the poor oxygen reduction and oxygen evolution reaction (ORR and OER) activities in discharge and charge processes cause low energy efficiency, poor electrolyte stability and short cycle life. This requires the development of efficient cathode catalysts to dramatically improve the Li-O2 battery performances. MnO2-based materials are recognized as efficient and low-cost catalysts for a Li-O2 battery cathode. Here, we report a controllable approach to synthesize hierarchical porous δ-MnO2 nanoboxes by using Prussian blue analogues as the precursors. The obtained products possess hierarchical pore size and an extremely large surface area (249.3 m2 g-1), which would favour oxygen transportation and provide more catalytically active sites to promote ORR and OER as the Li-O2 battery cathode. The battery shows enhanced discharge capacity (4368 mA h g-1@0.08 mA cm-2), reduced overpotential (270 mV), improved rate performance and excellent cycle stability (248 cycles@500 mA h g-1 and 112 cycles@1000 mA h g-1), in comparison with the battery with a VX-72 carbon cathode. The superb performance of the hierarchical porous δ-MnO2 nanoboxes, together with a convenient fabrication method, presents an alternative to develop advanced cathode catalysts for the Li-O2 battery.A rechargeable lithium-oxygen (Li-O2) battery with a remarkably high theoretical energy storage capacity has attracted enormous research attention. However, the poor oxygen reduction and oxygen evolution reaction (ORR and OER) activities in discharge and charge processes cause low energy efficiency, poor electrolyte stability and short cycle life. This requires the development of efficient cathode catalysts to dramatically improve the Li-O2 battery performances. MnO2-based materials are recognized as efficient and low-cost catalysts for a Li-O2 battery cathode. Here, we report a controllable approach to synthesize hierarchical porous δ-MnO2 nanoboxes by using Prussian blue analogues as the precursors. The obtained products possess hierarchical pore size and an extremely large surface area (249.3 m2 g-1), which would favour oxygen transportation and provide more catalytically active sites to promote ORR and OER as the Li-O2 battery cathode. The battery shows enhanced discharge capacity (4368 mA h g-1@0.08 mA cm-2), reduced overpotential (270 mV), improved rate performance and excellent cycle stability (248 cycles@500 mA h g-1 and 112 cycles@1000 mA h g-1), in comparison with the battery with a VX-72 carbon cathode. The superb performance of the hierarchical porous δ-MnO2 nanoboxes, together with a convenient fabrication method, presents an alternative to develop advanced cathode catalysts for the Li-O2 battery. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr02983j
Influence of sleep and meal schedules on performance peaks in competitive sprinters.
Javierre, C; Calvo, M; Díez, A; Garrido, E; Segura, R; Ventura, J L
1996-08-01
The influence of sleep and meal schedules on performance in short distance running was assessed in a group of 8 national-class competition male sprinters. They were tested on Saturdays for five consecutive weeks. On each testing day, the performance time for an 80 m sprint was registered on eight different occasions during days 1 and 4, on 9 occasions on days 2 and 5, and on 7 occasions on day 3. On control days (days 1 and 4) performance gradually improved during the morning up to 13:00 h, decreased at 15:00 h, and again improved thereafter, with a maximum peak performance at 19:00 h. On day 2, in which sleep/wake cycles and meal-times were advanced for two hours, and on day 3, in which timetables were delayed for two hours, maximum peak performance was observed at 17:00 h and 21:00 h, respectively. At the time of maximum peak performance on both days a statistically significant improvement was observed as compared with the control day (day 2, p < 0.01; day 3, p = 0.001). On day 5, in which only the sleep/wake cycle was advanced for two hours, performance in the afternoon and evening was similar to that recorded on days 1 and 4. We observed that easy manipulation of sleep and meal schedules would allow competitive sprinters to synchronize peak power output with the time of the athletic event, increasing the chances for improvement in performance.
Life cycle assessment of switchgrass- and corn stover-derived ethanol-fueled automobiles.
Spatari, Sabrina; Zhang, Yimin; MacLean, Heather L
2005-12-15
Utilizing domestically produced cellulose-derived ethanol for the light-duty vehicle fleet can potentially improve the environmental performance and sustainability of the transport and energy sectors of the economy. A life cycle assessment model was developed to examine environmental implications of the production and use of ethanol in automobiles in Ontario, Canada. The results were compared to those of low-sulfur reformulated gasoline (RFG) in a functionally equivalent automobile. Two time frames were evaluated, one near-term (2010), which examines converting a dedicated energy crop (switchgrass) and an agricultural residue (corn stover) to ethanol; and one midterm (2020), which assumes technological improvements in the switchgrass-derived ethanol life cycle. Near-term results show that, compared to a RFG automobile, life cycle greenhouse gas (GHG) emissions are 57% lower for an E85-fueled automobile derived from switchgrass and 65% lower for ethanol from corn stover, on a grams of CO2 equivalent per kilometer basis. Corn stover ethanol exhibits slightly lower life cycle GHG emissions, primarily due to sharing emissions with grain production. Through projected improvements in crop and ethanol yields, results for the mid-term scenario show that GHG emissions could be 25-35% lower than those in 2010 and that, even with anticipated improvements in RFG automobiles, E85 automobiles could still achieve up to 70% lower GHG emissions across the life cycle.
Gallien, Gabrielle; Bellar, David; Davis, Greggory R
2017-11-02
There is a limited supply of sport nutrition supplements currently available for vegan or vegetarian athletes. In addition, the efficacy of a vegan or vegetarian pre-workout supplement that does not contain any processed ingredients or stimulants is currently unknown. The purpose of the current study was to examine the effects of an unprocessed vegan pre-workout supplement on high-intensity cycling performance. Participants completed three separate cycling trials following the consumption of a vegan pre-workout supplement, an isocaloric processed supplement, or a zero-calorie placebo supplement. Each supplement was consumed 30 minutes prior to each trial, and each cycling trial was separated by a minimum of 72 hours. Supplements were administered using a randomized, double-blind cross-over design. Each cycling trial was performed at a workload equal to 80% VO 2peak until exhaustion. The average time in seconds (s) until exhaustion values for the vegan, isocaloric, and zero-calorie supplements were 482 ± 163, 480 ± 157, and 496 ± 238, respectively. Consumption of the vegan supplement did not significantly improve performance compared to an isocaloric and zero-calorie supplement (F = 0.12, p =.89). The results of this study indicate that individuals who choose a vegan pre-workout supplement (over an isocaloric or zero-calorie product) will not experience any acute decrements or ergogenic benefits in cycling performance. Although the present study does not support performance benefits of the tested vegan pre-workout supplement before cycling, additional research examining various exercise intensities and modalities is warranted.
Digital electronic engine control history
NASA Technical Reports Server (NTRS)
Putnam, T. W.
1984-01-01
Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.
Development of high-energy silicon-based anode materials for lithium-ion storage
NASA Astrophysics Data System (ADS)
Yi, Ran
The emerging markets of electric vehicles (EV) and hybrid electric vehicles (HEV) generate a tremendous demand for low-cost lithium-ion batteries (LIBs) with high energy and power densities, and long cycling life. The development of such LIBs requires development of low cost, high-energy-density cathode and anode materials. Conventional anode materials in commercial LIBs are primarily synthetic graphite-based materials with a capacity of ˜370 mAh/g. Improvements in anode performance, particularly in anode capacity, are essential to achieving high energy densities in LIBs for EV and HEV applications. This dissertation focuses on development of micro-sized silicon-carbon (Si-C) composites as anode materials for high energy and power densities LIBs. First, a new, low-cost, large-scale approach was developed to prepare a micro-sized Si-C composite with excellent performance as an anode material for LIBs. The composite shows a reversible capacity of 1459 mAh/g after 200 cycles at 1 A/g (97.8% capacity retention) and excellent high rate performance of 700 mAh/g at 12.8 A/g, and also has a high tap density of 0.78 g/cm3. The structure of the composite, micro-sized as a whole, features the interconnected nanoscale size of the Si building blocks and the uniform carbon filling, which enables the maximum utilization of silicon even when the micro-sized particles break into small pieces upon cycling. To understand the effects of key parameters in designing the micro-sized Si-C composites on their electrochemical performance and explore how to optimize them, the influence of Si nanoscale building block size and carbon coating on the electrochemical performance of the micro-sized Si-C composites were investigated. It has been found that the critical Si building block size is 15 nm, which enables a high capacity without compromising the cycling stability, and that carbon coating at higher temperature improves the 1st cycle coulombic efficiency (CE) and the rate capability. Corresponding reasons underneath electrochemical performance have been revealed by various characterizations. Combining both optimized Si building block size and carbon coating temperature, the resultant composite can sustain 600 cycles at 1.2 A/g with a fixed lithiation capacity of 1200 mAh/g, the best cycling performance with such a high capacity for micro-sized Si-based anodes. To further improve the the rate capability of Si-based anode materials, an effecitive method of facile boron doping was demonstrated. Boron-doped Si-C composite can deliver a high capacity of 575 mAh/g at 6.4 A/g without addition of any conductive additives, 80% higher than that of undoped composite. Compared to the obvious capacity fading of undoped Si-C composite, boron-doped Si-C composite maintains its capacity well upon long cycling at a high current density. Electrochemical impedance spectroscopy (EIS) measurement shows boron-doped Si-C composite has lower charge transfer resistance, which helps improve its rate capability. A novel micro-sized graphene/Si-C composite (G/Si-C) was then developed to translate the performance of such micro-sized Si-C composites from the material level to the electrode level aiming to achieve high areal capacities (mAh/cm2) besides gravimetric capacities (mAh/g). Owing to dual conductive networks both within single particles formed by carbon and between different particles formed by graphene, low electrical resistance can be maintained at high mass loading, which enables a high degree of material utilization. Areal capacity thus increases almost linearly with mass loading. As a result, G/Si-C exhibits a high areal capacity of 3.2 mAh/cm2 after 100 cycles with high coulombic efficiency (average 99.51% from 2nd to 100th cycle), comparable to that of commercial anodes. Finally, a micro-sized Si-based material (B-Si/SiO2/C) featuring high rate performance was developed via a facile route without use of toxic hydrofluoric acid. A Li-ion hybrid battery constructed of such a Si-based anode and a porous carbon cathode was demonstrated with both high power and energy densities. Boron-doping is employed to improve the rate capability of B-Si/SiO2/C. At a high current density of 6.4 A/g, B-Si/SiO 2/C delivers a capacity of 685 mAh/g, 2.4 times that of the undoped Si/SiO2/C. Benefiting from the high rate performance along with low working voltage, high capacity and good cycling stability of B-Si/SiO 2/C, the hybrid battery exhibits a high energy density of 128 Wh/kg at 1229 W/kg. Even when power density increases to the level of a conventional supercapacitor (9704 W/kg), 89 Wh/kg can be obtained, the highest values of any hybrid battery to date. Long cycling life (capacity retention of 70% after 6000 cycles) and low self-discharge rate (voltage retention of 82% after 50 hours) are also achieved.
Nevin, Jonpaul; Waldron, Mark; Patterson, Stephen; Smith, Paul; Price, Mike; Hunt, Alex
2018-03-20
The aim of the present study was to investigate the effects of an 8-week concurrent strength and endurance training programme in comparison to endurance training only on several key determinants of hand cycling performance. Five H4 and five H3 classified hand cyclists with at least one year's hand cycling training history consented to participate in the study. Subjects underwent a battery of tests to establish body mass, body composition, VO2peak, maximum aerobic power, gross mechanical efficiency, maximal upper body strength, and 30 km time trial performance. Subjects were matched into pairs based upon 30 km time trial performance and randomly allocated to either a concurrent strength and endurance or endurance training only, intervention group. Following an 8-week training programme based upon a conjugated block periodisation model, subjects completed a second battery of tests. A mixed model, 2-way analysis of variance (ANOVA) revealed no significant changes between groups. However, the calculation of effect sizes (ES) revealed that both groups demonstrated a positive improvement in most physiological and performance measures with subjects in the concurrent group demonstrating a greater magnitude of improvement in body composition (ES -0.80 vs. -0.22) maximal aerobic power (ES 0.97 vs. 0.28), gross mechanical efficiency (ES 0.87 vs. 0.63), bench press 1 repetition maximum (ES 0.53 vs. 0.33), seated row 1 repetition maximum (ES 1.42 vs. 0.43), and 30 km time trial performance (ES -0.66 vs. -0.30). In comparison to endurance training only, an 8-week concurrent training intervention based upon a conjugated block periodisation model appears to be a more effective training regime for improving the performance capabilities of hand cyclists.
NASA Astrophysics Data System (ADS)
Ahmadi, Mohammad H.; Ahmadi, Mohammad-Ali; Pourfayaz, Fathollah
2015-09-01
Developing new technologies like nano-technology improves the performance of the energy industries. Consequently, emerging new groups of thermal cycles in nano-scale can revolutionize the energy systems' future. This paper presents a thermo-dynamical study of a nano-scale irreversible Stirling engine cycle with the aim of optimizing the performance of the Stirling engine cycle. In the Stirling engine cycle the working fluid is an Ideal Maxwell-Boltzmann gas. Moreover, two different strategies are proposed for a multi-objective optimization issue, and the outcomes of each strategy are evaluated separately. The first strategy is proposed to maximize the ecological coefficient of performance (ECOP), the dimensionless ecological function (ecf) and the dimensionless thermo-economic objective function ( F . Furthermore, the second strategy is suggested to maximize the thermal efficiency ( η), the dimensionless ecological function (ecf) and the dimensionless thermo-economic objective function ( F). All the strategies in the present work are executed via a multi-objective evolutionary algorithms based on NSGA∥ method. Finally, to achieve the final answer in each strategy, three well-known decision makers are executed. Lastly, deviations of the outcomes gained in each strategy and each decision maker are evaluated separately.
Multivariable control of vapor compression systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X.D.; Liu, S.; Asada, H.H.
1999-07-01
This paper presents the results of a study of multi-input multi-output (MIMO) control of vapor compression cycles that have multiple actuators and sensors for regulating multiple outputs, e.g., superheat and evaporating temperature. The conventional single-input single-output (SISO) control was shown to have very limited performance. A low order lumped-parameter model was developed to describe the significant dynamics of vapor compression cycles. Dynamic modes were analyzed based on the low order model to provide physical insight of system dynamic behavior. To synthesize a MIMO control system, the Linear-Quadratic Gaussian (LQG) technique was applied to coordinate compressor speed and expansion valve openingmore » with guaranteed stability robustness in the design. Furthermore, to control a vapor compression cycle over a wide range of operating conditions where system nonlinearities become evident, a gain scheduling scheme was used so that the MIMO controller could adapt to changing operating conditions. Both analytical studies and experimental tests showed that the MIMO control could significantly improve the transient behavior of vapor compression cycles compared to the conventional SISO control scheme. The MIMO control proposed in this paper could be extended to the control of vapor compression cycles in a variety of HVAC and refrigeration applications to improve system performance and energy efficiency.« less
Polyanthraquinone-Based Organic Cathode for High-Performance Rechargeable Magnesium-Ion Batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Baofei; Huang, Jinhua; Feng, Zhenxing
2016-05-09
Two anthraquinone-based polymers aiming at improving the capacity and voltage of magnesium ion batteries, were synthesized and characterized. The excellent battery cycling performance was demonstrated with the electrolyte consisting of magnesium bis(hexamethyldisilazide) and magnesium chloride.
Figueiredo, Pedro; Marques, Elisa A; Lepers, Romuald
2016-09-01
Figueiredo, P, Marques, EA, and Lepers, R. Changes in contributions of swimming, cycling, and running performances on overall triathlon performance over a 26-year period. J Strength Cond Res 30(9): 2406-2415, 2016-This study examined the changes in the individual contribution of each discipline to the overall performance of Olympic and Ironman distance triathlons among men and women. Between 1989 and 2014, overall performances and their component disciplines (swimming, cycling and running) were analyzed from the top 50 overall male and female finishers. Regression analyses determined that for the Olympic distance, the split times in swimming and running decreased over the years (r = 0.25-0.43, p ≤ 0.05), whereas the cycling split and total time remained unchanged (p > 0.05), for both sexes. For the Ironman distance, the cycling and running splits and the total time decreased (r = 0.19-0.88, p ≤ 0.05), whereas swimming time remained stable, for both men and women. The average contribution of the swimming stage (∼18%) was smaller than the cycling and running stages (p ≤ 0.05), for both distances and both sexes. Running (∼47%) and then cycling (∼36%) had the greatest contribution to overall performance for the Olympic distance (∼47%), whereas for the Ironman distance, cycling and running presented similar contributions (∼40%, p > 0.05). Across the years, in the Olympic distance, swimming contribution significantly decreased for women and men (r = 0.51 and 0.68, p < 0.001, respectively), whereas running increased for men (r = 0.33, p = 0.014). In the Ironman distance, swimming and cycling contributions changed in an undulating fashion, being inverse between the two segments, for both sexes (p < 0.01), whereas running contribution decreased for men only (r = 0.61, p = 0.001). These findings highlight that strategies to improve running performance should be the main focus on the preparation to compete in the Olympic distance; whereas, in the Ironman, both cycling and running are decisive and should be well developed.
Liu, John D; Goodspeed, Danielle; Sheng, Zhengji; Li, Baohua; Yang, Yiran; Kliebenstein, Daniel J; Braam, Janet
2015-03-27
The modular body structure of plants enables detached plant organs, such as postharvest fruits and vegetables, to maintain active responsiveness to environmental stimuli, including daily cycles of light and darkness. Twenty-four hour light/darkness cycles entrain plant circadian clock rhythms, which provide advantage to plants. Here, we tested whether green leafy vegetables gain longevity advantage by being stored under light/dark cycles designed to maintain biological rhythms. Light/dark cycles during postharvest storage improved several aspects of plant tissue performance comparable to that provided by refrigeration. Tissue integrity, green coloration, and chlorophyll content were generally enhanced by cycling of light and darkness compared to constant light or darkness during storage. In addition, the levels of the phytonutrient glucosinolates in kale and cabbage remained at higher levels over time when the leaf tissue was stored under light/dark cycles. Maintenance of the daily cycling of light and dark periods during postharvest storage may slow the decline of plant tissues, such as green leafy vegetables, improving not only appearance but also the health value of the crops through the maintenance of chlorophyll and phytochemical content after harvest.
NASA Astrophysics Data System (ADS)
Liu, Boli; Liu, Zhengjiao; Li, Dan; Guo, Pengqian; Liu, Dequan; Shang, Xiaonan; Lv, Mingzhi; He, Deyan
2017-09-01
The rock-salt structural manganous sulfide (α-MnS) is of higher lithium storage capacity. To improve the cyclability of α-MnS anode in lithium-ion batteries, we prepared a composite of α-MnS nanocrystallites grown on nitrogen and sulfur co-doped reduced graphene oxide (rGO) honeycomb framework. N and S atoms have been co-doped into rGO along with the growth of the α-MnS nanocystallites by a one-pot hydrothermal synthesis using thiourea as dopant and reactant. The typical α-MnS/Nsbnd S co-doped rGO (NSG) composite electrode exhibits a reversible capacity as high as 763.5 mAh g-1 after 100 cycles at 100 mA g-1, and a reversible capacity of 576.7 mAh g-1 even after 2000 cycles at 1000 mA g-1. More importantly, the α-MnS/NSG composite electrodes show superior cycle performance at asymmetric discharge/charge current densities. The excellent electrochemical performance can be attributed to that the α-MnS nanocrystallites shorten lithium ion transmission distance, N-S co-doping improves the electronic conductivity of rGO, and the formation of chemical bonds combination between α-MnS and NSG enhances the electrode structural stability and the electron transport. In addition, more stable architecture of NSG-supported ultrafine α-MnS particles is formed upon cycling, which greatly enhances the electrical contact and further improves the electrochemical performance.
Standalone BISON Fuel Performance Results for Watts Bar Unit 1, Cycles 1-3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clarno, Kevin T.; Pawlowski, Roger; Stimpson, Shane
2016-03-07
The Consortium for Advanced Simulation of Light Water Reactors (CASL) is moving forward with more complex multiphysics simulations and increased focus on incorporating fuel performance analysis methods. The coupled neutronics/thermal-hydraulics capabilities within the Virtual Environment for Reactor Applications Core Simulator (VERA-CS) have become relatively stable, and major advances have been made in analysis efforts, including the simulation of twelve cycles of Watts Bar Nuclear Unit 1 (WBN1) operation. While this is a major achievement, the VERA-CS approaches for treating fuel pin heat transfer have well-known limitations that could be eliminated through better integration with the BISON fuel performance code. Severalmore » approaches are being implemented to consider fuel performance, including a more direct multiway coupling with Tiamat, as well as a more loosely coupled one-way approach with standalone BISON cases. Fuel performance typically undergoes an independent analysis using a standalone fuel performance code with manually specified input defined from an independent core simulator solution or set of assumptions. This report summarizes the improvements made since the initial milestone to execute BISON from VERA-CS output. Many of these improvements were prompted through tighter collaboration with the BISON development team at Idaho National Laboratory (INL). A brief description of WBN1 and some of the VERA-CS data used to simulate it are presented. Data from a small mesh sensitivity study are shown, which helps justify the mesh parameters used in this work. The multi-cycle results are presented, followed by the results for the first three cycles of WBN1 operation, particularly the parameters of interest to pellet-clad interaction (PCI) screening (fuel-clad gap closure, maximum centerline fuel temperature, maximum/minimum clad hoop stress, and cumulative damage index). Once the mechanics of this capability are functioning, future work will target cycles with known or suspected PCI failures to determine how well they can be estimated.« less
Improving integrated waste management at the regional level: the case of Lombardia.
Rigamonti, Lucia; Falbo, Alida; Grosso, Mario
2013-09-01
The article summarises the main results of the 'Gestione Rifiuti in Lombardia: Analisi del ciclo di vita' (Waste management in Lombardia region: Life cycle assessment; GERLA) project. Life cycle assessment (LCA) has been selected by Regione Lombardia as a strategic decision support tool in the drafting of its new waste management programme. The goal was to use the life cycle thinking approach to assess the current regional situation and thus to give useful strategic indications for the future waste management. The first phase of the study consisted of the LCA of the current management of municipal waste in the Lombardia region (reference year: 2009). The interpretation of such results has allowed the definition of four possible waste management scenarios for the year 2020, with the final goal being to improve the environmental performance of the regional system. The results showed that the current integrated waste management of Lombardia region is already characterised by good energy and environmental performances. However, there is still room for further improvement: actions based, on the one hand, on a further increase in recycling rates and, on the other hand, on a series of technological modifications, especially in food waste and residual waste management, can be undertaken to improve the overall system.
Dietary Nitrate Fails to Improve 1 and 4 km Cycling Performance in Highly Trained Cyclists.
McQuillan, Joseph A; Dulson, Deborah K; Laursen, Paul B; Kilding, Andrew E
2017-06-01
We aimed to compare the effects of two different dosing durations of dietary nitrate (NO 3 - ) supplementation on 1 and 4 km cycling time-trial performance in highly trained cyclists. In a double-blind crossover-design, nine highly trained cyclists ingested 140ml of NO 3 - -rich beetroot juice containing ~8.0mmol [NO 3 - ], or placebo, for seven days. Participants completed a range of laboratory-based trials to quantify physiological and perceptual responses and cycling performance: time-trials on day 3 and 6 (4km) and on day 4 and 7 (1km) of the supplementation period. Relative to placebo, effects following 3- and 4-days of NO 3 - supplementation were unclear for 4 (-0.8; 95% CL, ± 2.8%, p = .54) and likely harmful for 1km (-1.9; ± 2.5% CL, p = .17) time-trial mean power. Effects following 6- and 7-days of NO 3 - supplementation resulted in unclear effects for 4 (0.1; ± 2.2% CL, p = .93) and 1km (-0.9; ± 2.6%CL, p = .51) time-trial mean power. Relative to placebo, effects for 40, 50, and 60% peak power output were unclear for economy at days 3 and 6 of NO 3 - supplementation (p > .05). Dietary NO 3 - supplementation appears to be detrimental to 1km time-trial performance in highly trained cyclists after 4-days. While, extending NO 3 - dosing to ≥ 6-days reduced the magnitude of harm in both distances, overall performance in short duration cycling time-trials did not improve relative to placebo.
A 3D conductive carbon interlayer with ultrahigh adsorption capability for lithium-sulfur batteries
NASA Astrophysics Data System (ADS)
Zhao, Qian; Zhu, Qizhen; An, Yabin; Chen, Renjie; Sun, Ning; Wu, Feng; Xu, Bin
2018-05-01
To improve the cycling performance of the Li-S batteries, a 3D interwoven hollow interlayer with extremely high electrolyte adsorption capability up to 9.64 g g-1 was simply prepared by carbonization of cotton fabric (CCF). For comparison, an interlayer coated on separator was obtained by the slurry-coating method of powdery CCF. The key role of the adsorption capability is confirmed by comparing the electrochemical performance of Li-S batteries with these two interlayers. In the Li-S batteries with 3D CCF interlayer, massive dissolved polysulfides, together with the electrolyte, can be adsorbed and confined in the 3D CCF interlayer, providing substantial extra active sites and alleviating the shuttle effect effectively. As a result, the Li-S batteries with 3D CCF interlayer show much enhanced utilization of active materials (1346.9 mAh g-1 at 0.1C), prolonged cycle life (capacity retention of 80% after 100 cycles), and improved rate performance (553.2 mAh g-1 at 4C). Even for cathodes with high sulfur loading of 5 mg cm-2, the cells with 3D CCF interlayer perform a high capacity of 1085 mAh g-1 and retain 870.6 mAh g-1 after 75 cycles at 0.5 mA cm-2. These results not only provide a sustainable, low cost and easy-prepared 3D CCF interlayer, but also offer a promising strategy based on interlayer with high adsorption capability in designing high-performance Li-S batteries.
Egan-Shuttler, Julian D; Edmonds, Rohan; Eddy, Cassandra; O'Neill, Veronica; Ives, Stephen J
2017-12-01
Plyometric training has been shown to increase muscle power, running economy, and performance in athletes. Despite its use by rowing coaches, it is unknown whether plyometrics might improve rowing economy or performance. The purpose was to determine if plyometric training, in conjunction with training on the water, would lead to improved rowing economy and performance. Eighteen male high school rowers were assigned to perform 4 weeks of either plyometric training (PLYO, n = 9) or steady-state cycling below ventilatory threshold (endurance, E, n = 9), for 30 min prior to practice on the water (matched for training volume) 3 days per week. Rowing performance was assessed through a 500-m rowing time trial (TT) and peak rowing power (RP), while rowing economy (RE) was assessed by measuring the oxygen cost over four work rates (90, 120, 150, and 180 W). Rowing economy was improved in both PLYO and E (p < 0.05). The 500-m TT performance improved significantly for PLYO (from 99.8 ± 9 s to 94.6 ± 2 s, p < 0.05) but not for E (from 98.8 ± 6 s to 98.7 ± 5 s, p > 0.05). Finally, RP was moderately higher in the PLYO group post-training (E 569 ± 75 W, PLYO 629 ± 51 W, ES = 0.66) CONCLUSIONS: In a season when the athletes performed no rowing sprint training, 4 weeks of plyometric training improved the 500-m rowing performance and moderately improved peak power. This increase in performance may have been mediated by moderate improvements in rowing power, but not economy, and warrants further investigation.
NASA Astrophysics Data System (ADS)
Geng, Hongbo; Ang, Huixiang; Ding, Xianguang; Tan, Huiteng; Guo, Guile; Qu, Genlong; Yang, Yonggang; Zheng, Junwei; Yan, Qingyu; Gu, Hongwei
2016-01-01
In this work, a one-dimensional Co3O4@TiO2 core-shell electrode material with superior electrochemical performance is fabricated by a convenient and controllable route. The approach involves two main steps: the homogeneous deposition of polydopamine and TiO2 layers in sequence on the cobalt coordination polymer and the thermal decomposition of the polymer matrix. The as-prepared electrode material can achieve excellent electrochemical properties and stability as an anode material for lithium ion batteries, such as a high specific capacity of 1279 mA h g-1, good cycling stability (around 803 mA h g-1 at a current density of 200 mA g-1 after 100 cycles), and stable rate performance (around 520 mA h g-1 at a current density of 1000 mA g-1). This dramatic electrochemical performance is mainly attributed to the excellent structural characteristics, which could improve the electrical conductivity and lithium ion mobility, as well as electrolyte permeability and architectural stability during cycling.In this work, a one-dimensional Co3O4@TiO2 core-shell electrode material with superior electrochemical performance is fabricated by a convenient and controllable route. The approach involves two main steps: the homogeneous deposition of polydopamine and TiO2 layers in sequence on the cobalt coordination polymer and the thermal decomposition of the polymer matrix. The as-prepared electrode material can achieve excellent electrochemical properties and stability as an anode material for lithium ion batteries, such as a high specific capacity of 1279 mA h g-1, good cycling stability (around 803 mA h g-1 at a current density of 200 mA g-1 after 100 cycles), and stable rate performance (around 520 mA h g-1 at a current density of 1000 mA g-1). This dramatic electrochemical performance is mainly attributed to the excellent structural characteristics, which could improve the electrical conductivity and lithium ion mobility, as well as electrolyte permeability and architectural stability during cycling. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08570e
Improvement of the conductive network of positive electrodes and the performance of Ni-MH battery
NASA Astrophysics Data System (ADS)
Morimoto, Katsuya; Nakayama, Kousuke; Maki, Hideshi; Inoue, Hiroshi; Mizuhata, Minoru
2017-06-01
The pretreatment to modify the valence of cobalt by discharging at 0.2 C rate for 7.5 h before the first initial activation charge process is effective in improving the surface electronic conductivity among fine particles of positive electrode active materials. The discharge curves indicate the same locus within 1800 cycles, and the capacity of the pretreated battery is stable for over 4000 cycles. However, in-situ cell pretreatment with constant current has negative influence on other components. During the constant current pretreatment, the cell voltage rapidly falls to -0.5 V in the first 10 s of in-situ pretreatment. Therefore, we investigate the pretreatment by supplying a constant voltage to the battery instead of a constant current, and find the effective condition to improve the electrochemical performance and not to have any influence on other components of the battery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ziying; Lee, Jungwoo Z.; Xin, Huolin L.
All-solid-state lithium-ion batteries have the potential to not only push the current limits of energy density by utilizing Li metal, but also improve safety by avoiding flammable organic electrolyte. However, understanding the role of solid electrolyte – electrode interfaces will be critical to improve performance. In this paper, we conducted long term cycling on commercially available lithium cobalt oxide (LCO)/lithium phosphorus oxynitride (LiPON)/lithium (Li) cells at elevated temperature to investigate the interfacial phenomena that lead to capacity decay. STEM-EELS analysis of samples revealed a previously unreported disordered layer between the LCO cathode and LiPON electrolyte. This electrochemically inactive layer grewmore » in thickness leading to loss of capacity and increase of interfacial resistance when cycled at 80 °C. Finally, the stabilization of this layer through interfacial engineering is crucial to improve the long term performance of thin-film batteries especially under thermal stress.« less
Xu, Na; Qian, Tao; Liu, Xuejun; Liu, Jie; Chen, Yu; Yan, Chenglin
2017-01-11
The high solubility of long-chain lithium polysulfides and their infamous shuttle effect in lithium sulfur battery lead to rapid capacity fading along with low Coulombic efficiency. To address above issues, we propose a new strategy to suppress the shuttle effect for greatly enhanced lithium sulfur battery performance mainly through the formation of short-chain intermediates during discharging, which allows significant improvements including high capacity retention of 1022 mAh/g with 87% retention for 450 cycles. Without LiNO 3 -containing electrolytes, the excellent Coulombic efficiency of ∼99.5% for more than 500 cycles is obtained, suggesting the greatly suppressed shuttle effect. In situ UV/vis analysis of electrolyte during cycling reveals that the short-chain Li 2 S 2 and Li 2 S 3 polysulfides are detected as main intermediates, which are theoretically verified by density functional theory (DFT) calculations. Our strategy may open up a new avenue for practical application of lithium sulfur battery.
NASA Astrophysics Data System (ADS)
Mohanty, Debasish; Dahlberg, Kevin; King, David M.; David, Lamuel A.; Sefat, Athena S.; Wood, David L.; Daniel, Claus; Dhar, Subhash; Mahajan, Vishal; Lee, Myongjai; Albano, Fabio
2016-05-01
The energy density of current lithium-ion batteries (LIBs) based on layered LiMO2 cathodes (M = Ni, Mn, Co: NMC; M = Ni, Co, Al: NCA) needs to be improved significantly in order to compete with internal combustion engines and allow for widespread implementation of electric vehicles (EVs). In this report, we show that atomic layer deposition (ALD) of titania (TiO2) and alumina (Al2O3) on Ni-rich FCG NMC and NCA active material particles could substantially improve LIB performance and allow for increased upper cutoff voltage (UCV) during charging, which delivers significantly increased specific energy utilization. Our results show that Al2O3 coating improved the NMC cycling performance by 40% and the NCA cycling performance by 34% at 1 C/-1 C with respectively 4.35 V and 4.4 V UCV in 2 Ah pouch cells. High resolution TEM/SAED structural characterization revealed that Al2O3 coatings prevented surface-initiated layered-to-spinel phase transitions in coated materials which were prevalent in uncoated materials. EIS confirmed that Al2O3-coated materials had significantly lower increase in the charge transfer component of impedance during cycling. The ability to mitigate degradation mechanisms for Ni-rich NMC and NCA illustrated in this report provides insight into a method to enable the performance of high-voltage LIBs.
Mohanty, Debasish; Dahlberg, Kevin; King, David M.; David, Lamuel A.; Sefat, Athena S.; Wood, David L.; Daniel, Claus; Dhar, Subhash; Mahajan, Vishal; Lee, Myongjai; Albano, Fabio
2016-01-01
The energy density of current lithium-ion batteries (LIBs) based on layered LiMO2 cathodes (M = Ni, Mn, Co: NMC; M = Ni, Co, Al: NCA) needs to be improved significantly in order to compete with internal combustion engines and allow for widespread implementation of electric vehicles (EVs). In this report, we show that atomic layer deposition (ALD) of titania (TiO2) and alumina (Al2O3) on Ni-rich FCG NMC and NCA active material particles could substantially improve LIB performance and allow for increased upper cutoff voltage (UCV) during charging, which delivers significantly increased specific energy utilization. Our results show that Al2O3 coating improved the NMC cycling performance by 40% and the NCA cycling performance by 34% at 1 C/−1 C with respectively 4.35 V and 4.4 V UCV in 2 Ah pouch cells. High resolution TEM/SAED structural characterization revealed that Al2O3 coatings prevented surface-initiated layered-to-spinel phase transitions in coated materials which were prevalent in uncoated materials. EIS confirmed that Al2O3-coated materials had significantly lower increase in the charge transfer component of impedance during cycling. The ability to mitigate degradation mechanisms for Ni-rich NMC and NCA illustrated in this report provides insight into a method to enable the performance of high-voltage LIBs. PMID:27226071
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Debasish; Dahlberg, Kevin; King, David M.
2016-05-26
The energy density of current lithium-ion batteries (LIBs) based on layered LiMO 2 cathodes (M=Ni, Mn, Co: NMC; M=Ni, Co, Al: NCA) needs to be improved significantly in order to compete with internal combustion engines and allow for widespread implementation of electric vehicles (EVs). In this report, we show that atomic layer deposition (ALD) of titania (TiO 2) and alumina (Al 2O 3) on Ni-rich FCG NMC and NCA active material particles could substantially improve LIB performance and allow for increased upper cutoff voltage (UCV) during charging, which delivers significantly increased specific energy utilization. Our results show that Al2O3 coatingmore » improved the NMC cycling performance by 40% and the NCA cycling performance by 34% at 1C/₋1C with respectively 4.35V and 4.4V UCV in 2Ah pouch cells. High resolution TEM/SAED structural characterization revealed that Al 2O 3 coatings prevented surface-initiated layered-to-spinel phase transitions in coated materials which were prevalent in uncoated materials. Lastly, EIS confirmed that Al 2O 3-coated materials had significantly lower increase in the charge transfer component of impedance during cycling. In conclusion, the ability to mitigate degradation mechanisms for Ni-rich NMC and NCA illustrated in this report provides insight into a method to enable the performance of high-voltage LIBs.« less
SnO2/Reduced Graphene Oxide Interlayer Mitigating the Shuttle Effect of Li-S Batteries.
Hu, Nana; Lv, Xingshuai; Dai, Ying; Fan, Linlin; Xiong, Dongbin; Li, Xifei
2018-06-06
The short cycle life of lithium-sulfur batteries (LSBs) plagues its practical application. In this study, a uniform SnO 2 /reduced graphene oxide (denoted as SnO 2 /rGO) composite is successfully designed onto the commercial polypropylene separator for use of interlayer of LSBs to decrease the charge-transfer resistance and trap the soluble lithium polysulfides (LPSs). As a result, the assembled devices using the separator modified with the functional interlayer (SnO 2 /rGO) exhibit improved cycle performance; for instance, over 200 cycles at 1C, the discharge capacity of the cells reaches 734 mAh g -1 . The cells also display high rate capability, with the average discharge capacity of 541.9 mAh g -1 at 5C. Additionally, the mechanism of anchoring behavior of the SnO 2 /rGO interlayer was systematically investigated using density functional theory calculations. The results demonstrate that the improved performance is related to the ability of SnO 2 /rGO to effectively absorb S 8 cluster and LPS. The strong Li-O/Sn-S/O-S bonds and tight chemical adsorption between LPS and SnO 2 mitigate the shuttle effect of LSBs. This study demonstrates that engineering the functional interlayer of metal oxide and carbon materials in LSBs may be an easy way to improve their rate capacity and cycling life.
Improved Cognition While Cycling in Parkinson’s Disease Patients and Healthy Adults
Hazamy, Audrey A.; Altmann, Lori J. P.; Stegemöller, Elizabeth; Bowers, Dawn; Lee, Hyo Keun; Wilson, Jonathan; Okun, Michael S.; Hass, Chris J.
2017-01-01
Persons with Parkinson’s disease (PD) are typically more susceptible than healthy adults to impaired performance when two tasks (dual task interference) are performed simultaneously. This limitation has by many experts been attributed to limitations in cognitive resources. Nearly all studies of dual task performance in PD employ walking or balance-based motor tasks, which are commonly impaired in PD. These tasks can be performed using a combination of one or two executive function tasks. The current study examined whether persons with PD would demonstrate greater dual task effects on cognition compared to healthy older adults (HOAs) during a concurrent cycling task. Participants with and without PD completed a battery of 12 cognitive tasks assessing visual and verbal processing in the following cognitive domains: speed of processing, controlled processing, working memory and executive function. Persons with PD exhibited impairments compared to healthy participants in select tasks (i.e., 0-Back, 2-Back and operation span). Further, both groups unexpectedly exhibited dual task facilitation of response times in visual tasks across cognitive domains, and improved verbal recall during an executive function task. Only one measure, 2-back, showed a speed-accuracy trade-off in the dual task. These results demonstrate that, when paired with a motor task in which they are not impaired, people with PD exhibit similar dual task effects on cognitive tasks as HOAs, even when these dual task effects are facilitative. More generally, these findings demonstrate that pairing cognitive tasks with cycling may actually improve cognitive performance which may have therapeutic relevance to cognitive decline associated with aging and PD pathology. PMID:28088064
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kucha, E.I.
1984-01-01
A general method was developed to calculate two dimensional (axisymmetric) mixing of a compressible jet in a variable cross-sectional area mixing channel of the ejector. The analysis considers mixing of the primary and secondary fluids at constant pressure and incorporates finite difference approximations to the conservation equations. The flow model is based on the mixing length approximations. A detailed study and modeling of the flow phenomenon determines the best (optimum) mixing channel geometry of the ejector. The detailed ejector performance characteristics are predicted by incorporating the flow model into a solar-powered ejector cycle cooling system computer model. Freon-11 is usedmore » as both the primary and secondary fluids. Performance evaluation of the cooling system is examined for its coefficient of performance (COP) under a variety of operating conditions. A study is also conducted on a modified ejector cycle in which a secondary pump is introduced at the exit of the evaporator. Results show a significant improvement in the overall performance over that of the conventional ejector cycle (without a secondary pump). Comparison between one and two-dimensional analyses indicates that the two-dimensional ejector fluid flow analysis predicts a better overall system performance. This is true for both the conventional and modified ejector cycles.« less
NASA Astrophysics Data System (ADS)
Kasnatscheew, Johannes; Evertz, Marco; Streipert, Benjamin; Wagner, Ralf; Nowak, Sascha; Cekic Laskovic, Isidora; Winter, Martin
2017-08-01
Increasing the specific energy of a lithium ion battery and maintaining its cycle life is a predominant goal and major challenge for electrochemical energy storage applications. Focusing on the positive electrode as the specific energy bottleneck, cycle life characteristics of promising layered oxide type active materials (LiMO2) has been thoroughly investigated. Comparing the variety of LiMO2 compositions, it could be shown that the "Ni-rich" (Ni ≥ 60% for M in LiMO2) electrodes expectably revealed best performance compromises between specific energy and cycle life at 20 °C, but only LiNi0.6Mn0.2Co0.2O2 (NMC622) could also maintain sufficient cycle performance at elevated temperatures. Focusing on NMC622, it could be demonstrated that the applied electrochemical conditions (charge capacity, delithiation amount) in the formation cycles significantly influence the subsequent cycling performance. Moreover, the insignificant transition metal dissolution, demonstrated by means of total X-ray fluorescence (TXRF) technique, and unchanged lithiation degree in the discharged state, determined by the measurement of the Li+ content by means of the inductively coupled plasma optical emission spectroscopy (ICP-OES) technique, pointed to a delithiation (charge) hindrance capacity fade mechanism. Considering these insights, thoughtful modifications of the electrochemical charge conditions could significantly prolong the cycle life.
NASA Astrophysics Data System (ADS)
Tan, Yingying; Chen, Youming; Wang, Lin
2018-06-01
A mixed refrigerant ejector refrigeration cycle operating with two-stage vapor-liquid separators (MRERC2) is proposed to obtain refrigeration temperature at -40°C. The thermodynamic investigations on performance of MRERC2 using zeotropic mixture refrigerant R23/R134a are performed, and the comparisons of cycle performance between MRERC2 and MRERC1 (MRERC with one-stage vapor-liquid separator) are conducted. The results show that MRERC2 can achieve refrigeration temperature varying between -23.9°C and -42.0°C when ejector pressure ratio ranges from 1.6 to 2.3 at the generation temperature of 57.3-84.9°C. The parametric analysis indicates that increasing condensing temperature decreases coefficient of performance ( COP) of MRERC2, and increasing ejector pressure ratio and mass fraction of the low boiling point component in the mixed refrigerant can improve COP of MRERC2. The MRERC2 shows its potential in utilizing low grade thermal energy as driving power to obtain low refrigeration temperature for the ejector refrigeration cycle.
Can FES-Augmented Active Cycling Training Improve Locomotion in Post-Acute Elderly Stroke Patients?
Peri, Elisabetta; Ambrosini, Emilia; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Nava, Claudia; Longoni, Valentina; Monticone, Marco; Ferrante, Simona
2016-01-01
Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only). This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results. PMID:27990234
Can FES-Augmented Active Cycling Training Improve Locomotion in Post-Acute Elderly Stroke Patients?
Peri, Elisabetta; Ambrosini, Emilia; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Nava, Claudia; Longoni, Valentina; Monticone, Marco; Ferrante, Simona
2016-06-13
Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only). This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results.
NASA Astrophysics Data System (ADS)
Shu, Haibo; Li, Feng; Hu, Chenli; Liang, Pei; Cao, Dan; Chen, Xiaoshuang
2016-01-01
Two-dimensional (2D) layered MoS2 nanosheets possess great potential as anode materials for lithium ion batteries (LIBs), but they still suffer from poor cycling performance. Improving the cycling stability of electrode materials depends on a deep understanding of their dynamic structural evolution and reaction kinetics in the lithiation process. Herein, thermodynamic phase diagrams and the lithiation dynamics of MoS2-based nanostructures with the intercalation of lithium ions are studied by using first-principles calculations and ab initio molecular dynamics simulations. Our results demonstrate that the continuous intercalation of Li ions induces structural destruction of 2H phase MoS2 nanosheets in the discharge process that follows a layer-by-layer dissociation mechanism. Meanwhile, the intercalation of Li ions leads to a structural transition of MoS2 nanosheets from the 2H to the 1T phase due to the ultralow transition barriers (~0.1 eV). We find that the phase transition can slow down the dissociation of MoS2 nanosheets during lithiation. The result can be applied to explain extensive experimental observation of the fast capacity fading of MoS2-based anode materials between the first and the subsequent discharges. To suppress the dissociation of MoS2 nanosheets in the lithiation process, we propose a strategy by constructing a sandwich-like graphene/MoS2/graphene structure that indicates high chemical stability, superior conductivity, and high Li-ion mobility in the charge/discharge process, implying the possibility to induce an improvement in the anode cycling performance. This work opens a new route to rational design layered transition-metal disulfide (TMD) anode materials for LIBs with superior cycling stability and electrochemical performance.Two-dimensional (2D) layered MoS2 nanosheets possess great potential as anode materials for lithium ion batteries (LIBs), but they still suffer from poor cycling performance. Improving the cycling stability of electrode materials depends on a deep understanding of their dynamic structural evolution and reaction kinetics in the lithiation process. Herein, thermodynamic phase diagrams and the lithiation dynamics of MoS2-based nanostructures with the intercalation of lithium ions are studied by using first-principles calculations and ab initio molecular dynamics simulations. Our results demonstrate that the continuous intercalation of Li ions induces structural destruction of 2H phase MoS2 nanosheets in the discharge process that follows a layer-by-layer dissociation mechanism. Meanwhile, the intercalation of Li ions leads to a structural transition of MoS2 nanosheets from the 2H to the 1T phase due to the ultralow transition barriers (~0.1 eV). We find that the phase transition can slow down the dissociation of MoS2 nanosheets during lithiation. The result can be applied to explain extensive experimental observation of the fast capacity fading of MoS2-based anode materials between the first and the subsequent discharges. To suppress the dissociation of MoS2 nanosheets in the lithiation process, we propose a strategy by constructing a sandwich-like graphene/MoS2/graphene structure that indicates high chemical stability, superior conductivity, and high Li-ion mobility in the charge/discharge process, implying the possibility to induce an improvement in the anode cycling performance. This work opens a new route to rational design layered transition-metal disulfide (TMD) anode materials for LIBs with superior cycling stability and electrochemical performance. Electronic supplementary information (ESI) available: Models and energetics of Li adsorption/intercalation onto MoS2 sheets, details of the phase diagram calculations, schematic illustration for the structural evolution of lithiated MoS2 nanosheets, AIMD trajectories for lithiated silicene/MoS2/silicene composites, and movies for recording the AIMD simulation results. See DOI: 10.1039/c5nr07909h
NASA Technical Reports Server (NTRS)
Howlett, R. A.
1975-01-01
A continuation of the NASA/P and WA study to evaluate various types of propulsion systems for advanced commercial supersonic transports has resulted in the identification of two very promising engine concepts. They are the Variable Stream Control Engine which provides independent temperature and velocity control for two coannular exhaust streams, and a derivative of this engine, a Variable Cycle Engine that employs a rear flow-inverter valve to vary the bypass ratio of the cycle. Both concepts are based on advanced engine technology and have the potential for significant improvements in jet noise, exhaust emissions and economic characteristics relative to current technology supersonic engines. Extensive research and technology programs are required in several critical areas that are unique to these supersonic Variable Cycle Engines to realize these potential improvements. Parametric cycle and integration studies of conventional and Variable Cycle Engines are reviewed, features of the two most promising engine concepts are described, and critical technology requirements and required programs are summarized.
Trevisi, E; Gualdi, S; De Conti, C; Salghetti, A; Martinuzzi, A; Pedrocchi, A; Ferrante, S
2012-03-01
Recently, the efficacy of functional electrical stimulation (FES) cycling have been demonstrated on the improvement of strength and motor control in adults with stroke. FES-cycling, providing a repetitive goal-oriented task, could facilitate cortical reorganization and utilization of residual cortico-spinal pathways. These benefits could be more enhanced in children because of the greater plasticity and flexibility of their central nervous system. The aim of the present case report study was to explore the feasibility of FES-cycling in children with cerebral palsy (CP) and to provide a set of instrumental measures able to evaluate the effects of this novel treatment on cycling and walking ability. Interventional study. Two ambulant outpatient children with diplegic CP were recruited by the "E. Medea" Scientific Institute. Patients followed a FES-cycling treatment for 30 minutes a day, 3 days a week for 7 weeks. Pre and post treatment tests were performed, namely clinical measures and electromyographic, kinematic and oxygen expenditure analysis during gait and cycling. The treatment was safe, feasible and well accepted by the 2 children. After treatment both patients achieved a more symmetrical muscular strategy during voluntary cycling and gait and a significant reduction of muscle co-contractions during cycling. These improvements were corroborated by a decrease in oxygen expenditure during the post test for one of the two children, the less impaired, implying a better exploiting of bi-articular muscles. FES-cycling is feasible and safe and it may be an alternative rehabilitation method for diplegic CP patients. The set of instrumental measurements proposed seems to be a valuable tool for functional assessment to identify subclinical anomalies and improvements on cycling and gait in CP patients.
Current State of Military Hybrid Vehicle Development
2011-08-31
Integrated starter generator for engine shut down, regenerative braking and avoidance of inefficient engine operation [28]. FMTV VI Composite 6-9% Fuel...and eliminating the inefficiencies associated with idling, vehicle braking and low engine speed part load efficiency, many improvements could be...different drive cycles were being used to evaluate vehicle performance. These cycles can be divided into the following two categories : (1) Time
A queueing network model to analyze the impact of parallelization of care on patient cycle time.
Jiang, Lixiang; Giachetti, Ronald E
2008-09-01
The total time a patient spends in an outpatient facility, called the patient cycle time, is a major contributor to overall patient satisfaction. A frequently recommended strategy to reduce the total time is to perform some activities in parallel thereby shortening patient cycle time. To analyze patient cycle time this paper extends and improves upon existing multi-class open queueing network model (MOQN) so that the patient flow in an urgent care center can be modeled. Results of the model are analyzed using data from an urgent care center contemplating greater parallelization of patient care activities. The results indicate that parallelization can reduce the cycle time for those patient classes which require more than one diagnostic and/ or treatment intervention. However, for many patient classes there would be little if any improvement, indicating the importance of tools to analyze business process reengineering rules. The paper makes contributions by implementing an approximation for fork/join queues in the network and by improving the approximation for multiple server queues in both low traffic and high traffic conditions. We demonstrate the accuracy of the MOQN results through comparisons to simulation results.
NASA Astrophysics Data System (ADS)
Oh, Dahyun; Qi, Jifa; Lu, Yi-Chun; Zhang, Yong; Shao-Horn, Yang; Belcher, Angela M.
2013-11-01
Lithium-oxygen batteries have a great potential to enhance the gravimetric energy density of fully packaged batteries by two to three times that of lithium ion cells. Recent studies have focused on finding stable electrolytes to address poor cycling capability and improve practical limitations of current lithium-oxygen batteries. In this study, the catalyst electrode, where discharge products are deposited and decomposed, was investigated as it has a critical role in the operation of rechargeable lithium-oxygen batteries. Here we report the electrode design principle to improve specific capacity and cycling performance of lithium-oxygen batteries by utilizing high-efficiency nanocatalysts assembled by M13 virus with earth-abundant elements such as manganese oxides. By incorporating only 3-5 wt% of palladium nanoparticles in the electrode, this hybrid nanocatalyst achieves 13,350 mAh g-1c (7,340 mAh g-1c+catalyst) of specific capacity at 0.4 A g-1c and a stable cycle life up to 50 cycles (4,000 mAh g-1c, 400 mAh g-1c+catalyst) at 1 A g-1c.
How an educational improvement project improved the summative evaluation of medical students.
Hoffman, K G; Brown, R Margaret A; Gay, J W; Headrick, L A
2009-08-01
At the University of Missouri-Columbia School of Medicine (USA) "commitment to improving quality and safety in healthcare" is one of eight key characteristics set as goals for our graduates. As educators, commitment to continuous improvement in the educational experience has been modelled through improvement of the Medical Student Performance Evaluation (MSPE) letter (formerly the Dean's letter). This educational improvement project decreased waste, increased collaboration and developed locally useful knowledge. By applying continuous improvement principles to the construction of the MSPE the overall efficiency of the process could be enhanced, and the MSPE committee was able to spend less cognitive energy on structure and format and focus more on the content of the letters. Four MSPE cycles have been completed using a new Web-based system; after each cycle, additional enhancements were identified and implemented. This work adds to the literature, as it describes the application of continuous improvement principles to an educational system.
Improved Li storage performance in SnO 2 nanocrystals by a synergetic doping
Wan, Ning; Lu, Xia; Wang, Yuesheng; ...
2016-01-06
Tin dioxide (SnO 2) is a widely investigated lithium (Li) storage material because of its easy preparation, two-step storage mechanism and high specific capacity for lithium-ion batteries (LIBs). In this contribution, a phase-pure cobalt-doped SnO 2 (Co/SnO 2) and a cobalt and nitrogen co-doped SnO 2 (Co-N/SnO 2) nanocrystals are prepared to explore their Li storage behaviors. It is found that the morphology, specific surface area, and electrochemical properties could be largely modulated in the doped and co-doped SnO 2 nanocrystals. Gavalnostatic cycling results indicate that the Co-N/SnO 2 electrode delivers a specific capacity as high as 716 mAh gmore » –1 after 50 cycles, and the same outstanding rate performance can be observed in subsequent cycles due to the ionic/electronic conductivity enhancement by co-doping effect. Further, microstructure observation indicates the existence of intermediate phase of Li 3N with high ionic conductivity upon cycling, which probably accounts for the improvements of Co-N/SnO 2 electrodes. Furthermore, we find that the method of synergetic doping into SnO 2 with Co and N, with which the electrochemical performances is enhanced remarkably, undoubtedly, will have an important influence on the material itself and community of LIBs as well.« less
NASA Technical Reports Server (NTRS)
Smart, M. C.; Ratnakumar, B. V.; West, W. C.; Brandon, E. J.
2012-01-01
Demonstrated improved performance with wide operating temperature electrolytes containing ester co - solvents (i.e., methyl propionate and ethyl butyrate) in a number of prototype cells: center dot Successfully scaled up low temperature technology to 12 Ah size prismatic Li - ion cells (Quallion, LCC), and demonstrated good performance down to - 60 o C. center dot Demonstrated wide operating temperature range performance ( - 60 o to +60 o C) in A123 Systems LiFePO 4 - based lithium - ion cells containing methyl butyrate - based low temperature electrolytes. These systems were also demonstrated to have excellent cycle life performance at ambient temperatures, as well as the ability to be cycled up to high temperatures.
Thermally Stabilized Transmit/Receive Modules
NASA Technical Reports Server (NTRS)
Hoffman, James; DelCastillo, Linda; Miller, Jennifer; Birur, Gaj
2011-01-01
RF-hybrid technologies enable smaller packaging and mass reduction in radar instruments, especially for subsystems with dense electronics, such as electronically steered arrays. We are designing thermally stabilized RF-hybrid T/R modules using new materials for improved thermal performance of electronics. We are combining advanced substrate and housing materials with a thermal reservoir material, and develop new packaging techniques to significantly improve thermal-cycling reliability and performance stability over temperature.
NASA Astrophysics Data System (ADS)
Liang, Sijie; Guo, Li; Lin, Genmei; Zhang, Zhongyi; Ding, Haiyan; Wang, Yamei; Yang, Guanpin
2017-07-01
Nannochloropsis oceanica promises to be an industrial-level producer of polyunsaturated fatty acids. In this study, the fastest and slowest growing N. oceanica mutants were selected through N-methyl-N'-nitro-N-nitrosoguanidine mutation, and two mutant strains and the wild type (WT) subjected to transcriptome profiling. It was found that the OD680 reads at stationary growth phase of both WT and its mutants were proportional to their cell density, thus indicating their division rate and growth speed during culture. This chemical mutation was effective for improving growth performance, and the fast strain divided faster by upregulating the expression of genes functioning in the cell cycle and downregulating genes involved in synthesis of amino acids, fatty acids, and sugars as well as the construction of ribosome and photosynthetic machinery. However, the relationship among the effected genes responsible for cell cycle, metabolism of fatty and amino acids, and construction of ribosome and photosynthetic machinery remained unclear. Further genetic studies are required for clarifying the genetic/metabolic networks underpinning the growth performance of N. oceanica. These findings demonstrated that this mutation strategy was effective for improving the growth performance of this species and explored a means of microalgal genetic improvement, particularly in species possessing a monoploid nucleus and asexual reproduction.
Variable cycle engines for advanced supersonic transports
NASA Technical Reports Server (NTRS)
Howlett, R. A.; Kozlowski, H.
1975-01-01
Variable Cycle Engines being studied for advanced commercial supersonic transports show potential for significant environmental and economic improvements relative to 1st generation SST engines. The two most promising concepts are: a Variable Stream Control Engine and a Variable Cycle Engine with a rear flow-control valve. Each concept utilizes variable components and separate burners to provide independent temperature and velocity control for two coannular flow streams. Unique fuel control techniques are combined with cycle characteristics that provide low fuel consumption, similar to a turbojet engine, for supersonic operation. This is accomplished while retaining the good subsonic performance features of a turbofan engine. A two-stream coannular nozzle shows potential to reduce jet noise to below FAR Part 36 without suppressors. Advanced burner concepts have the potential for significant reductions in exhaust emissions. In total, these unique engine concepts have the potential for significant overall improvements to the environmental and economic characteristics of advanced supersonic transports.
Clothes Dryer Automatic Termination Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
TeGrotenhuis, Ward E.
Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this reportmore » shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.« less
On-Chip Supercapacitor Electrode Based On Polypyrrole Deposited Into Nanoporous Au Scaffold
NASA Astrophysics Data System (ADS)
Lu, P.; Ohlckers, P.; Chen, X. Y.
2016-11-01
On-chip supercapacitors hold the potential promise for serving as the energy storage units in integrated circuit system, due to their much higher energy density in comparison with conventional dielectric capacitors, high power density and long-term cycling stability. In this study, nanoporous Au (NP-Au) film on-chip was employed as the electrode scaffold to help increase the electrolyte-accessible area for active material. Pseudo-capacitive polypyrrole (PPY) with high theoretical capacitance was deposited into the NP-Au scaffold, to construct the tailored NP-Au/PPY hybrid on-chip electrode with improved areal capacitance. Half cell test in three- electrode system revealed the improved capacitor performance of nanoporous Au supported PPY electrode, compared to the densely packed PPY nanowire film electrode on planer Au substrate (Au/PPY). The areal capacitance of 37 mF/cm2∼10 mV/s, 32 mF/cm2∼50 mV/s, 28 mF/cm2∼100 mV/s, 16 mF/cm2∼500 mV/s, were offered by NP-Au/PPY. Also, the cycling performance was enhanced via using NP-Au scaffold. The developed NP-Au/PPY on-chip electrode demonstrated herein paves a feasible pathway to employ dealloying derived porous metal as the scaffold for improving both the energy density and cycling performance for supercapacitor electrodes.
Yang, Zhixiong; Li, Rengui; Deng, ZhengHua
2018-04-25
To achieve the higher capacity and the better cycle performance of the lithium-sulfur (L-S) batteries, a copolymer electrolyte prepared via emulsifier-free emulsion polymerization was used as the binder for the sulfur cathode in this study. This polyelectrolyte binder has uniform dispersion and good Li + conductivity in the cathode that can improve the kinetics of sulfur electrochemical reactions. As a result, the capacity and cycle performance of the battery are improved evidently when the cell is discharged to 1.8 V. Moreover, when the cell is discharged to 1.5 V, the difficult deposition of Li 2 S 2 will take place easily at 1.75 V, and the difficult transformation from solid Li 2 S 2 to solid Li 2 S will progress smoothly and completely during the voltage range of 1.55-1.75 V, too. The capacity of this L-S battery discharged to 1.5 V is as much as 1700 mAh g -1 , which is very close to the theoretical value of sulfur cathode. The knowledge acquired in this study is valuable not only for the design of an efficient new polyelectrolyte binder for sulfur cathode but also the discovery that the discharge degree is the main fact that limits the capacity to reach its theoretical value.
NASA Astrophysics Data System (ADS)
Dagger, Tim; Grützke, Martin; Reichert, Matthias; Haetge, Jan; Nowak, Sascha; Winter, Martin; Schappacher, Falko M.
2017-12-01
In order to address the trade-off between the safety lithium ion battery (LIB) electrolytes and their electrochemical performance, synergetic effects of flame retardant additives (FRs) in combination with film forming additives (FFAs) are investigated. Triphenyl phosphate (TPP) and a silicon-containing additive (WA) are applied as FRs to improve the onset temperature of the thermal runaway of a LIB standard electrolyte (LP57: 1 M LiPF6 in EC:EMC 3:7) about 15 K and 28 K, respectively. The application of the FRs in MCMB graphite/lithium metal and NMC111/lithium metal three-electrode cells induces insufficiencies in terms of charge/discharge cycling stability and rate capability. It is investigated if the addition of FFAs can degrade the insufficiencies that are induced by the FRs. Vinylene carbonate, vinyl ethylene carbonate and fluoroethylene carbonate are added to a mixture of LP57 with 10% FR to enhance the cycling performance via improved interphase formation. Results reveal, that the rate capability of cells containing TPP or WA is especially improved by addition of 2% or 5% FEC, respectively. Postmortem analyses of the electrodes by SEM and of the electrolyte by GC-MS are performed. Direct correlations between the cycling behavior during the C-rate study and the electrolyte decomposition products are drawn.
Performance Improvement of V-Fe-Cr-Ti Solid State Hydrogen Storage Materials in Impure Hydrogen Gas.
Ulmer, Ulrich; Oertel, Daria; Diemant, Thomas; Bonatto Minella, Christian; Bergfeldt, Thomas; Dittmeyer, Roland; Behm, R Jürgen; Fichtner, Maximilian
2018-01-17
Two approaches of engineering surface structures of V-Ti-based solid solution hydrogen storage alloys are presented, which enable improved tolerance toward gaseous oxygen (O 2 ) impurities in hydrogen (H 2 ) gas. Surface modification is achieved through engineering lanthanum (La)- or nickel (Ni)-rich surface layers with enhanced cyclic stability in an H 2 /O 2 mixture. The formation of a Ni-rich surface layer does not improve the cycling stability in H 2 /O 2 mixtures. Mischmetal (Mm, a mixture of La and Ce) agglomerates are observed within the bulk and surface of the alloy when small amounts of this material are added during arc melting synthesis. These agglomerates provide hydrogen-transparent diffusion pathways into the bulk of the V-Ti-Cr-Fe hydrogen storage alloy when the remaining oxidized surface is already nontransparent for hydrogen. Thus, the cycling stability of the alloy is improved in an O 2 -containing hydrogen environment as compared to the same alloy without addition of Mm. The obtained surface-engineered storage material still absorbs hydrogen after 20 cycles in a hydrogen-oxygen mixture, while the original material is already deactivated after 4 cycles.
Demura, Shinichi; Morishita, Koji; Yamada, Takayoshi; Yamaji, Shunsuke; Komatsu, Miho
2011-11-01
L-Ornithine plays an important role in ammonia metabolism via the urea cycle. This study aimed to examine the effect of L-ornithine hydrochloride ingestion on ammonia metabolism and performance after intermittent maximal anaerobic cycle ergometer exercise. Ten healthy young adults (age, 23.8 ± 3.9 year; height, 172.3 ± 5.5 cm; body mass, 67.7 ± 6.1 kg) with regular training experience ingested L-ornithine hydrochloride (0.1 g/kg, body mass) or placebo after 30 s of maximal cycling exercise. Five sets of the same maximal cycling exercise were conducted 60 min after ingestion, and maximal cycling exercise was conducted after a 15 min rest. The intensity of cycling exercise was based on each subject's body mass (0.74 N kg(-1)). Work volume (watt), peak rpm (rpm) before and after intermittent maximal ergometer exercise and the following serum parameters were measured before ingestion, immediately after exercise and 15 min after exercise: ornithine, ammonia, urea, lactic acid and glutamate. Peak rpm was significantly greater with L-ornithine hydrochloride ingestion than with placebo ingestion. Serum ornithine level was significantly greater with L-ornithine hydrochloride ingestion than with placebo ingestion immediately and 15 min after intermittent maximal cycle ergometer exercise. In conclusion, although maximal anaerobic performance may be improved by L-ornithine hydrochloride ingestion before intermittent maximal anaerobic cycle ergometer exercise, the above may not depend on increase of ammonia metabolism with L-ornithine hydrochloride.
Induction motor speed control using varied duty cycle terminal voltage via PI controller
NASA Astrophysics Data System (ADS)
Azwin, A.; Ahmed, S.
2018-03-01
This paper deals with the PI speed controller for the three-phase induction motor using PWM technique. The PWM generated signal is utilized for voltage source inverter with an optimal duty cycle on a simplified induction motor model. A control algorithm for generating PWM control signal is developed. Obtained results shows that the steady state error and overshoot of the developed system is in the limit under different speed and load condition. The robustness of the control performance would be potential for induction motor performance improvement.
Warm-up effects from concomitant use of vibration and static stretching after cycling.
Yang, Wen-Wen; Liu, Chiang; Shiang, Tzyy-Yuang
2017-04-01
Static stretch is routinely used in traditional warm-up but impaired muscle performance. Combining vibration with static stretching as a feasible component may be an alternative to static stretching after submaximal aerobic exercise to improve jumping as well as flexibility. Therefore, the purpose of this study was to investigate and compare the effects of aerobic exercise, static stretching, and vibration with static stretching on flexibility and vertical jumping performance. A repeated measures experimental design was used in this study. Twelve participants randomly underwent 5 different warm-ups including cycling alone (C warm-up), static stretching alone (S warm-up), combining vibration with static stretching (VS warm-up), cycling followed by S (C+S warm-up), and cycling followed by VS (C+VS warm-up) on 5 separate days. Sit-and-reach, squat jump (SJ), and counter movement jump (CMJ) were measured for pre- and post- tests. The sit-and-reach scores after the S, VS, C+S and C+VS warm-ups were significantly enhanced (P<0.001), and were significantly greater than that of the C warm-up (P<0.05). The jumping height of SJ and CMJ after the C and C+VS warm-ups were significantly increased (P<0.05), whereas a significant reduction was found after the S warm-up (P<0.05). Vibration combined with stretching after submaximal cycling exercise (C+VS warm-up) could be a feasible warm-up protocol to improve both flexibility and vertical jump performance, compared with the traditional warm-up (C+S warm-up).
Kavaliauskas, Mykolas; Aspe, Rodrigo R; Babraj, John
2015-08-01
The work-to-rest ratio during cycling-based high-intensity interval training (HIT) could be important in regulating physiological and performance adaptations. We sought to determine the effectiveness of cycling-based HIT with different work-to-rest ratios for long-distance running. Thirty-two long-distance runners (age: 39 ± 8 years; sex: 14 men, 18 women; average weekly running training volume: 25 miles) underwent baseline testing (3-km time-trial, V[Combining Dot Above]O2peak and time to exhaustion, and Wingate test) before a 2-week matched-work cycling HIT of 6 × 10-second sprints with different rest periods (30 seconds [R30], 80 seconds [R80], 120 seconds [R120], or control). Three-kilometer time trial was significantly improved in the R30 group only (3.1 ± 4.0%, p = 0.04), whereas time to exhaustion was significantly increased in the 2 groups with a lower work-to-rest ratio (R30 group 6.4 ± 6.3%, p = 0.003 vs. R80 group 4.4 ± 2.7%, p = 0.03 vs. R120 group 1.9 ± 5.0%, p = 0.2). However, improvements in average power production were significantly greater with a higher work-to-rest ratio (R30 group 0.3 ± 4.1%, p = 0.8 vs. R80 group 4.6 ± 4.2%, p = 0.03 vs. R120 group 5.3 ± 5.9%, p = 0.02), whereas peak power significantly increased only in the R80 group (8.5 ± 8.2%, p = 0.04) but not in the R30 group (4.3 ± 6.1%, p = 0.3) or in the R120 group (7.1 ± 7.9%, p = 0.09). Therefore, cycling-based HIT is an effective way to improve running performance, and the type and magnitude of adaptation is dependent on the work-to-rest ratio.
Enhancing Financial Performance: An Application of Lean Six Sigma to Reduce Insurance Claim Denials.
Kovach, Jamison V; Borikar, Shrutika
Health systems typically lose approximately 3% to 5% of net revenues annually due to insurance claim denials. While most denials can be appealed, the administrative burden of sorting through and appealing them can be time consuming and delays the revenue collection process. This article describes how the Lean Six Sigma methodology was used to improve the revenue cycle by reducing insurance claim denials for a leading pediatric hospital in the United States. The use of this approach is demonstrated through a case example focused on reducing denials by improving the hospital's Emergency Center registration process. Multiple pilot tests were performed to ensure the proposed changes sufficiently addressed the problem of missing/incomplete insurance information. Results indicated that the revised registration form reduced missing/incomplete fields by 67%. As a result, the revised form was implemented, which helped greatly reduce insurance claim denials. In addition to providing an example from which other health systems can learn to successfully implement Lean Six Sigma to enhance the performance of their revenue cycle, this work helped the hospital in which this research was performed improve its patient experience by making it easier for patients to complete their Emergency Center registration form.
Inertial aided cycle slip detection and identification for integrated PPP GPS and INS.
Du, Shuang; Gao, Yang
2012-10-25
The recently developed integrated Precise Point Positioning (PPP) GPS/INS system can be useful to many applications, such as UAV navigation systems, land vehicle/machine automation and mobile mapping systems. Since carrier phase measurements are the primary observables in PPP GPS, cycle slips, which often occur due to high dynamics, signal obstructions and low satellite elevation, must be detected and repaired in order to ensure the navigation performance. In this research, a new algorithm of cycle slip detection and identification has been developed. With the aiding from INS, the proposed method jointly uses WL and EWL phase combinations to uniquely determine cycle slips in the L1 and L2 frequencies. To verify the efficiency of the algorithm, both tactical-grade and consumer-grade IMUs are tested by using a real dataset collected from two field tests. The results indicate that the proposed algorithm can efficiently detect and identify the cycle slips and subsequently improve the navigation performance of the integrated system.
Understanding Leadership Paradigms for Improvement in Higher Education
ERIC Educational Resources Information Center
Flumerfelt, Shannon; Banachowski, Michael
2011-01-01
Purpose: This research article is based on the Baldrige National Quality Program Education Criteria for Performance Excellence's conceptualization of improvement as a dual cycle/three element initiative of examining and bettering inputs, processes, and outputs as driven by measurement, analysis and knowledge management work. This study isolates a…
Zheng, Xiangzhen; Huang, Tao; Pan, Ying; Wang, Wenguo; Fang, Guihuang; Ding, Kaining; Wu, Maoxiang
2017-06-07
The present study demonstrates that the use of alkyl 3,3,3-trifluoropropanoate, including methyl 3,3,3-trifluoropropanoate (TFPM) and ethyl 3,3,3-trifluoropropanoate (TFPE), as new electrolyte additive can dramatically enhance the high-voltage performance of LiNi 1/3 Co 1/3 Mn 1/3 O 2 /graphite lithium-ion batteries (3.0-4.6 V, vs Li/Li + ). The capacity retention was significantly increased from 45.6% to 75.4% after 100 charge-discharge cycles due to the addition of 0.2 wt % TFPM in the electrolyte, and significantly increased from 45.6% to 76.1% after 100 charge-discharge cycles due to the addition of 0.5 wt % TFPE in the electrolyte, verifying their suitability in this application. Electrochemical impedance spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy, and X-ray photoelectron spectroscopy were employed to study the effect of TFPM and TFPE on cell performance. The data indicates that the improved cycling activity can be ascribed to the participation of TFPM or TFPE in the formation of a thinner cathode/electrolyte interfacial film, thereby enhancing the cell cycling performance owing to a reduced interfacial resistance at high voltage.
Method and apparatus for improving the performance of a nuclear power electrical generation system
Tsiklauri, Georgi V.; Durst, Bruce M.
1995-01-01
A method and apparatus for improving the efficiency and performance a of nuclear electrical generation system that comprises the addition of steam handling equipment to an existing plant that results in a surprising increase in plant performance. More particularly, a gas turbine electrical generation system with heat recovery boiler is installed along with a high pressure and a low pressure mixer superheater. Depending upon plant characteristics, the existing moisture separator reheater (MSR) can be either augmented or done away with. The instant invention enables a reduction in T.sub.hot without a derating of the reactor unit, and improves efficiency of the plant's electrical conversion cycle. Coupled with this advantage is a possible extension of the plant's fuel cycle length due to an increased electrical conversion efficiency. The reduction in T.sub.hot further allows for a surprising extension of steam generator life. An additional advantage is the reduction in erosion/corrosion of secondary system components including turbine blades and diaphragms. The gas turbine generator used in the instant invention can also replace or augment existing peak or emergency power needs.
St Hilaire, Melissa A; Rüger, Melanie; Fratelli, Federico; Hull, Joseph T; Phillips, Andrew J K; Lockley, Steven W
2017-01-01
Intraindividual night-to-night sleep duration is often insufficient and variable. Here we report the effects of such chronic variable sleep deficiency on neurobehavioral performance and the ability of state-of-the-art models to predict these changes. Eight healthy males (mean age ± SD: 23.9 ± 2.4 years) studied at our inpatient intensive physiologic monitoring unit completed an 11-day protocol with a baseline 10-hour sleep opportunity and three cycles of two 3-hour time-in-bed (TIB) and one 10-hour TIB sleep opportunities. Participants received one of three polychromatic white light interventions (200 lux 4100K, 200 or 400 lux 17000K) for 3.5 hours on the morning following the second 3-hour TIB opportunity each cycle. Neurocognitive performance was assessed using the psychomotor vigilance test (PVT) administered every 1-2 hours. PVT data were compared to predictions of five group-average mathematical models that incorporate chronic sleep loss functions. While PVT performance deteriorated cumulatively following each cycle of two 3-hour sleep opportunities, and improved following each 10-hour sleep opportunity, performance declined cumulatively throughout the protocol at a more accelerated rate than predicted by state-of-the-art group-average mathematical models. Subjective sleepiness did not reflect performance. The light interventions had minimal effect. Despite apparent recovery following each extended sleep opportunity, residual performance impairment remained and deteriorated rapidly when rechallenged with subsequent sleep loss. None of the group-average models were capable of predicting both the build-up in impairment and recovery profile of performance observed at the group or individual level, raising concerns regarding their use in real-world settings to predict performance and improve safety. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
Jiao, Xinyan; Hao, Qingli; Xia, Xifeng; Lei, Wu; Ouyang, Yu; Ye, Haitao; Mandler, Daniel
2018-03-09
The incorporation of spacers between graphene sheets has been investigated as an effective method to improve the electrochemical performance of graphene papers (GPs) for supercapacitors. Here, we report the design of free-standing GP@NiO and GP@Ni hybrid GPs in which NiO nanoclusters and Ni nanoparticles are encapsulated into graphene sheets through electrostatic assembly and subsequent vacuum filtration. The encapsulated NiO nanoclusters and Ni nanoparticles can mitigate the restacking of graphene sheets, providing sufficient spaces for high-speed ion diffusion and electron transport. In addition, the spacers strongly bind to graphene sheets, which can efficiently improve the electrochemical stability. Therefore, at a current density of 0.5 A g -1 , the GP@NiO and GP@Ni electrodes exhibit higher specific capacitances of 306.9 and 246.1 F g -1 than the GP electrode (185.7 F g -1 ). The GP@NiO and GP@Ni electrodes exhibit capacitance retention of 98.7 % and 95.6 % after 10000 cycles, demonstrating an outstanding cycling stability. Additionally, the GP@NiO∥GP@Ni delivers excellent cycling stability (93.7 % after 10 000 cycles) and high energy density. These free-standing encapsulated hybrid GPs have great potential as electrode for high-performance supercapacitors. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
The hidden KPI registration accuracy.
Shorrosh, Paul
2011-09-01
Determining the registration accuracy rate is fundamental to improving revenue cycle key performance indicators. A registration quality assurance (QA) process allows errors to be corrected before bills are sent and helps registrars learn from their mistakes. Tools are available to help patient access staff who perform registration QA manually.
NASA Astrophysics Data System (ADS)
Yang, Chun-Chen; Hung, Yen-Wei; Lue, Shingjiang Jessie
2016-09-01
In this work, a LiFe0.5Mn0.5PO4/C (LFMP/C) material was prepared by a simple solid-state ball-mill method by using LiH2PO4, γ-MnO2, and hollow α-Fe2O3 nano-sized materials. Both γ-MnO2 and hollow α-Fe2O3 were synthesized by a hydrothermal process. LFMP/C composites coated with different amounts (1-3wt%) of Li4Ti5O12 (LTO) were synthesized by a sol-gel method. Their typical properties are studied using X-ray diffraction, micro-Raman spectroscopy, scanning electron microscopy/energy-dispersive X-ray spectroscopy, transmission electron microscopy, the AC impedance method, and the galvanostatic charge-discharge method. The results revealed that a 1 wt%-LTO-coated LFMP/C composite shows the highest performance among all LFMP/C composite samples. The long-term cycling performance of the LFMP/C composite improves considerably when the LTO ionic conductor is applied on it. Moreover, the 1 wt%-LTO-coated LFMP/C composite, which has the lowest fading rate, maintains high cycling stability at 1 C (141 mAh g-1) and 10 C (133 mAh g-1) at 55 °C after 100 cycles; by contrast, a bare LFMP/C sample, which demonstrates the highest fading rate, exhibits an unfavorable life cycle, and its discharge capacity decreases rapidly. The ionic conductor coating thus improves the high-temperature performance of LFMP/C composites. A LFMP/C-KS6/SiO2 full cell is assembled and tested.
Conductive Polymeric Binder for Lithium-Ion Battery Anode
NASA Astrophysics Data System (ADS)
Gao, Tianxiang
Tin (Sn) has a high-specific capacity (993 mAhg-1) as an anode material for Li-ion batteries. To overcome the poor cycling performance issue caused by its large volume expansion and pulverization during the charging and discharging process, many researchers put efforts into it. Most of the strategies are through nanostructured material design and introducing conductive polymer binders that serve as matrix of the active material in anode. This thesis aims for developing a novel method for preparing the anode to improve the capacity retention rate. This would require the anode to have high electrical conductivity, high ionic conductivity, and good mechanical properties, especially elasticity. Here the incorporation of a conducting polymer and a conductive hydrogel in Sn-based anodes using a one-step electrochemical deposition via a 3-electrode cell method is reported: the Sn particles and conductive component can be electrochemically synthesized and simultaneously deposited into a hybrid thin film onto the working electrode directly forming the anode. A well-defined three dimensional network structure consisting of Sn nanoparticles coated by conducting polymers is achieved. Such a conductive polymer-hydrogel network has multiple advantageous features: meshporous polymeric structure can offer the pathway for lithium ion transfer between the anode and electrolyte; the continuous electrically conductive polypyrrole network, with the electrostatic interaction with elastic, porous hydrogel, poly (2-acrylamido-2-methyl-1-propanesulfonic acid-co-acrylonitrile) (PAMPS) as both the crosslinker and doping anion for polypyrrole (PPy) can decrease the volume expansion by creating porous scaffold and softening the system itself. Furthermore, by increasing the amount of PAMPS and creating an interval can improve the cycling performance, resulting in improved capacity retention about 80% after 20 cycles, compared with only 54% of that of the control sample without PAMPS. The cycle is performed under current of 0.1 C.
A performance improvement plan to increase nurse adherence to use of medication safety software.
Gavriloff, Carrie
2012-08-01
Nurses can protect patients receiving intravenous (IV) medication by using medication safety software to program "smart" pumps to administer IV medications. After a patient safety event identified inconsistent use of medication safety software by nurses, a performance improvement team implemented the Deming Cycle performance improvement methodology. The combined use of improved direct care nurse communication, programming strategies, staff education, medication safety champions, adherence monitoring, and technology acquisition resulted in a statistically significant (p < .001) increase in nurse adherence to using medication safety software from 28% to above 85%, exceeding national benchmark adherence rates (Cohen, Cooke, Husch & Woodley, 2007; Carefusion, 2011). Copyright © 2012 Elsevier Inc. All rights reserved.
Advanced supersonic propulsion study, phases 3 and 4. [variable cycle engines
NASA Technical Reports Server (NTRS)
Allan, R. D.; Joy, W.
1977-01-01
An evaluation of various advanced propulsion concepts for supersonic cruise aircraft resulted in the identification of the double-bypass variable cycle engine as the most promising concept. This engine design utilizes special variable geometry components and an annular exhaust nozzle to provide high take-off thrust and low jet noise. The engine also provides good performance at both supersonic cruise and subsonic cruise. Emission characteristics are excellent. The advanced technology double-bypass variable cycle engine offers an improvement in aircraft range performance relative to earlier supersonic jet engine designs and yet at a lower level of engine noise. Research and technology programs required in certain design areas for this engine concept to realize its potential benefits include refined parametric analysis of selected variable cycle engines, screening of additional unconventional concepts, and engine preliminary design studies. Required critical technology programs are summarized.
Tunneled Mesoporous Carbon Nanofibers with Embedded ZnO Nanoparticles for Ultrafast Lithium Storage.
An, Geon-Hyoung; Lee, Do-Young; Ahn, Hyo-Jin
2017-04-12
Carbon and metal oxide composites have received considerable attention as anode materials for Li-ion batteries (LIBs) owing to their excellent cycling stability and high specific capacity based on the chemical and physical stability of carbon and the high theoretical specific capacity of metal oxides. However, efforts to obtain ultrafast cycling stability in carbon and metal oxide composites at high current density for practical applications still face important challenges because of the longer Li-ion diffusion pathway, which leads to poor ultrafast performance during cycling. Here, tunneled mesoporous carbon nanofibers with embedded ZnO nanoparticles (TMCNF/ZnO) are synthesized by electrospinning, carbonization, and postcalcination. The optimized TMCNF/ZnO shows improved electrochemical performance, delivering outstanding ultrafast cycling stability, indicating a higher specific capacity than previously reported ZnO-based anode materials in LIBs. Therefore, the unique architecture of TMCNF/ZnO has potential for use as an anode material in ultrafast LIBs.
[Stimulation of D1-receptors improves passive avoidance learning of female rats during ovary cycle].
Fedotova, Iu O; Sapronov, N S
2012-01-01
The involvement of D1-receptors in learning/memory processes during ovary cycle was assessed in the adult female rats. SKF-38393 (0,1 mg/kg, i.p.), D1-receptor agonist and SCH-23390 (0,1 mg/kg, i.p.), D1-receptor antagonist were injected chronically to adult female rats. Learning of these animals was assessed in different models: passive avoidance performance and Morris water maze. Chronic SKF-3839 administration to females resulted in the appearance of the passive avoidance performance in proestrous and estrous, as distinct from the control animals, but failed to change the dynamics of spatial learning in Morris water maze. Chronic SCH-23390 administration similarly impaired non-spatial and spatial learning in females during all phases of ovary cycle. The results of the study suggest modulating role of D1-receptors in learning/memory processes during ovary cycle in the adult female rats.
Fabrication and testing of silver-hydrogen cells
NASA Technical Reports Server (NTRS)
Klein, M. G.
1978-01-01
The development and life testing of single electrode and multi electrode stacks to optimize the individual components and characterize the performance of a silver hydrogen battery system are described. A NASA-developed inorganic separator material was used as the main separator within the cells. Single electrode test cells were cycled at 75% of nominal capacity out through approximately 1,000 cycles in a number of cases where deterioration in performance was observed. This deterioration appears to be a decay in usable capacity of the silver electrode; but the exact mechanism is still unidentified. Twenty ampere-hour boilerplate test cells consisting of a stack of ten silver electrodes and twenty hydrogen electrodes were cycled also at 75% depth of discharge. The oldest stack achieved 522 stable cycles to the end of the program. Weight analysis of light-weight cells showed that 50 ampere-hour cells with improved components could be capable of as much as 40 watt hours per pound.
High geothermal energy utilization geothermal/fossil hybrid power cycle: a preliminary investigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grijalva, R. L.; Sanemitsu, S. K.
1978-11-01
Combining geothermal and fossil fuel energy into the so-called hybrid cycle is compared with a state-of-the-art double-flash geothermal power cycle using resources which vary from 429/sup 0/K (312/sup 0/F) to 588/sup 0/K (598/sup 0/F). It is demonstrated that a hybrid plant can compete thermodynamically with the combined output from both a fossil-fired and a geothermal plant operating separately. Economic comparison of the hybrid and double-flash cycles is outlined, and results are presented that indicate the performance of marginal hydrothermal resources may be improved enough to compete with existing power cycles on a cost basis. It is also concluded that onmore » a site-specific basis a hybrid cycle is capable of complementing double-flash cycles at large-capacity resources, and can operate in a cycling load mode at constant geothermal fluid flow rate.« less
Novel iron oxide nanotube arrays as high-performance anodes for lithium ion batteries
NASA Astrophysics Data System (ADS)
Zhong, Yuan; Fan, Huiqing; Chang, Ling; Shao, Haibo; Wang, Jianming; Zhang, Jianqing; Cao, Chu-nan
2015-11-01
Nanostructured iron oxides can be promising anode materials for lithium ion batteries (LIBs). However, improvement on the rate capability and/or electrochemical cycling stability of iron oxide anode materials remains a key challenge because of their poor electrical conductivities and large volume expansion during cycling. Herein, the vertically aligned arrays of one-dimensional (1D) iron oxide nanotubes with 5.8 wt% carbon have been fabricated by a novel surfactant-free self-corrosion process and subsequent thermal treatment. The as-fabricated nanotube array electrode delivers a reversible capacity of 932 mAh g-1 after 50 charge-discharge cycles at a current of 0.6 A g-1. The electrode still shows a reversible capacity of 610 mAh g-1 even at a very high rate (8.0 A g-1), demonstrating its prominent rate capability. Furthermore, the nanotube array electrode also exhibits the excellent electrochemical cycling stability with a reversible capacity of 880 mAh g-1 after 500 cycles at a current of 4 A g-1. The nanotube array electrode with superior lithium storage performance reveals the promising potential as a high-performance anode for LIBs.
NASA Astrophysics Data System (ADS)
Liu, Yi; Ning, De; Zheng, Lirong; Zhang, Qinghua; Gu, Lin; Gao, Rui; Zhang, Jicheng; Franz, Alexandra; Schumacher, Gerhard; Liu, Xiangfeng
2018-01-01
Li-rich layered oxide cathodes suffer from poor rate capability, voltage decay and inferior cycling stability. Herein, we propose a novel synergistic strategy to improve the electrochemical performances of Li-rich Li1.20Ni0.13Co0.13Mn0.54O2 by the co-doping of Na+ and PO43-. The co-doping of Na+ for Li and PO43- for Mn is simultaneously achieved using Na3PO4 as a dopant. The co-doping of Na+ and PO43- not only enhances the high-rate performance (106.4 mAhg-1@10C) and capacity retention (93.8%@1C@100 cycles) but also mitigates the voltage decay owing to the synergistic effect of Na+ and PO43- co-doping. The synergistic mechanism is unraveled based on neutron diffraction, aberration-corrected scanning transmission electron microscope, X-ray photoelectron spectroscopy, ex-situ X-ray absorption spectra, ex-situ X-ray diffraction, electrochemical impedance spectroscopy and electrochemical measurements. The co-doping of Na+ and PO43- enlarges the interlayer spacing and suppresses Li/Ni mixing which increases Li+ diffusivity and enhances the rate capability. Meanwhile, the co-doping of Na+ and PO43- shrinks the thickness of the slabs, weakens the TM-O covalency and alleviates the volume change in the charge/discharge process which improves the layered structure stability and the cycling performances. This study presents some new insights into designing high performance cathode materials through a cooperative modulation of different crystal sites doping.
Effect of SPM-based cleaning POR on EUV mask performance
NASA Astrophysics Data System (ADS)
Choi, Jaehyuck; Lee, Han-shin; Yoon, Jinsang; Shimomura, Takeya; Friz, Alex; Montgomery, Cecilia; Ma, Andy; Goodwin, Frank; Kang, Daehyuk; Chung, Paul; Shin, Inkyun; Cho, H.
2011-11-01
EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. The fact that a pellicle is not used to protect the mask surface in EUV lithography suggests that EUV masks may have to undergo more cleaning cycles during their lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality and patterning performance during 30 cycles of Samsung's EUV mask SPM-based cleaning and 20 cycles of SEMATECH ADT exposure. We have observed that the quality and patterning performance of EUV masks does not significantly change during these processes except mask pattern CD change. To resolve this issue, we have developed an acid-free cleaning POR and substantially improved EUV mask film loss compared to the SPM-based cleaning POR.
Lesnock, Jamie L; Farris, Coreen; Krivak, Thomas C; Smith, Kenneth J; Markman, Maurie
2011-09-01
Randomized trials have demonstrated significant improvements in progression-free survival (PFS) with consolidation paclitaxel (P) and bevacizumab (B) following cytoreduction and adjuvant carboplatin/paclitaxel (CP) for advanced epithelial ovarian cancer (EOC). We sought to evaluate the cost-effectiveness (C/E) of these consolidation strategies. A decision model was developed based on Gynecologic Oncology Group (GOG) protocols #178 and #218. Arm 1 is 6 cycles of CP. Arm 2 is 6 cycles of CP followed by 12 cycles of P (CP+P). Arm 3 is 1 cycle of CP, 5 cycles of CPB, and 16 cycles of B (CPB+B). Parameters include PFS, overall survival (OS), cost, complications (neuropathy for P and bowel perforation for B), and quality-of-life utility values. Sensitivity analyses were performed. The incremental cost-effectiveness ratio (ICER) for CT+T is $13,402/quality adjusted life year (QALY) gained compared to CP. For CPB+B compared to CP, the ICER is $326,530/QALY. When compared simultaneously, CPB+B is dominated, i.e. is more costly and less effective than CP+P. Results were robust to parameter variation. At a willingness to pay threshold of $100,000/QALY, CP+P was the preferred option throughout most of the decision space. Sensitivity analyses suggest that CPB+B would become the preferred option if it were to improve OS by 6.1 years over CP+P. In this model, B consolidation for advanced EOC was associated with a modest improvement in effectiveness that is less than that with P consolidation and more costly. A statistically significant improvement in survival may improve the value of B consolidation. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Feng, Lili; Zhang, Yinyin; Wang, Rui; Zhang, Yanli; Bai, Wei; Ji, Siping; Xuan, Zhewen; Yang, Jianhua; Zheng, Ziguang; Guan, Hongjin
2017-09-01
MnO2@PPy core-shell micromaterials are prepared by chemical polymerization of pyrrole on the MnO2 surface. The polypyrrole (PPy) is formed as a homogeneous organic shell on the MnO2 surface. The thickness of PPy shell can be adjusted by the usage of pyrrole. The analysis of SEM, FT-IR, X-ray photoelectron spectroscopy (XPS), thermo-gravimetric analysis (TGA), and XRD are used to confirm the formation of PPy shell. Galvanostatic cell cycling and electrochemical impedance spectroscopy (EIS) are used to evaluate the electrochemical performance as anode for lithium-ion batteries. The results show that after formation of MnO2@PPy core-shell micromaterials, the cyclic performance as anode for lithium-ion batteries is improved. Fifty microliters of PPy-coated caddice-clew-like MnO2 has the best cyclic performances as has 620 mAh g-1 discharge specific capacities after 300 cycles. As a comparison, the discharge specific capacity of bare MnO2 materials falls to below 200 mAh g-1 after 10 cycles. The improved lithium-storage cyclic stability of the MnO2@PPy samples attributes to the core-shell hybrid structure which can buffer the structural expansion and contraction of MnO2 caused by the repeated embedding and disengagement of Li ions and can prevent the pulverization of MnO2. This experiment provides an effective way to mitigate the problem of capacity fading of the transition metal oxide materials as anode materials for (lithium-ion batteries) LIBs.
Feng, Lili; Zhang, Yinyin; Wang, Rui; Zhang, Yanli; Bai, Wei; Ji, Siping; Xuan, Zhewen; Yang, Jianhua; Zheng, Ziguang; Guan, Hongjin
2017-09-02
MnO 2 @PPy core-shell micromaterials are prepared by chemical polymerization of pyrrole on the MnO 2 surface. The polypyrrole (PPy) is formed as a homogeneous organic shell on the MnO 2 surface. The thickness of PPy shell can be adjusted by the usage of pyrrole. The analysis of SEM, FT-IR, X-ray photoelectron spectroscopy (XPS), thermo-gravimetric analysis (TGA), and XRD are used to confirm the formation of PPy shell. Galvanostatic cell cycling and electrochemical impedance spectroscopy (EIS) are used to evaluate the electrochemical performance as anode for lithium-ion batteries. The results show that after formation of MnO 2 @PPy core-shell micromaterials, the cyclic performance as anode for lithium-ion batteries is improved. Fifty microliters of PPy-coated caddice-clew-like MnO 2 has the best cyclic performances as has 620 mAh g -1 discharge specific capacities after 300 cycles. As a comparison, the discharge specific capacity of bare MnO 2 materials falls to below 200 mAh g -1 after 10 cycles. The improved lithium-storage cyclic stability of the MnO 2 @PPy samples attributes to the core-shell hybrid structure which can buffer the structural expansion and contraction of MnO 2 caused by the repeated embedding and disengagement of Li ions and can prevent the pulverization of MnO 2 . This experiment provides an effective way to mitigate the problem of capacity fading of the transition metal oxide materials as anode materials for (lithium-ion batteries) LIBs.
Combined glucose ingestion and mouth rinsing improves sprint cycling performance.
Chong, Edwin; Guelfi, Kym J; Fournier, Paul A
2014-12-01
This study investigated whether combined ingestion and mouth rinsing with a carbohydrate solution could improve maximal sprint cycling performance. Twelve competitive male cyclists ingested 100 ml of one of the following solutions 20 min before exercise in a randomized double-blinded counterbalanced order (a) 10% glucose solution, (b) 0.05% aspartame solution, (c) 9.0% maltodextrin solution, or (d) water as a control. Fifteen min after ingestion, repeated mouth rinsing was carried out with 11 × 15 ml bolus doses of the same solution at 30-s intervals. Each participant then performed a 45-s maximal sprint effort on a cycle ergometer. Peak power output was significantly higher in response to the glucose trial (1188 ± 166 W) compared with the water (1036 ± 177 W), aspartame (1088 ± 128 W) and maltodextrin (1024 ± 202 W) trials by 14.7 ± 10.6, 9.2 ± 4.6 and 16.0 ± 6.0% respectively (p < .05). Mean power output during the sprint was significantly higher in the glucose trial compared with maltodextrin (p < .05) and also tended to be higher than the water trial (p = .075). Glucose and maltodextrin resulted in a similar increase in blood glucose, and the responses of blood lactate and pH to sprinting did not differ significantly between treatments (p > .05). These findings suggest that combining the ingestion of glucose with glucose mouth rinsing improves maximal sprint performance. This ergogenic effect is unlikely to be related to changes in blood glucose, sweetness, or energy sensing mechanisms in the gastrointestinal tract.
NASA Astrophysics Data System (ADS)
Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren
2015-10-01
High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg-1), a high power density (27.5 kW kg-1) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg-1), a high power density (27.5 kW kg-1) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs. Electronic supplementary information (ESI) available: SEM images, XPS spectra, equivalent circuit, and CVs. See DOI: 10.1039/c5nr04449a
Steam bottoming cycle for an adiabatic diesel engine
NASA Technical Reports Server (NTRS)
Poulin, E.; Demier, R.; Krepchin, I.; Walker, D.
1984-01-01
Steam bottoming cycles using adiabatic diesel engine exhaust heat which projected substantial performance and economic benefits for long haul trucks were studied. Steam cycle and system component variables, system cost, size and performance were analyzed. An 811 K/6.90 MPa state of the art reciprocating expander steam system with a monotube boiler and radiator core condenser was selected for preliminary design. The costs of the diesel with bottoming system (TC/B) and a NASA specified turbocompound adiabatic diesel with aftercooling with the same total output were compared, the annual fuel savings less the added maintenance cost was determined to cover the increase initial cost of the TC/B system in a payback period of 2.3 years. Steam bottoming system freeze protection strategies were developed, technological advances required for improved system reliability are considered and the cost and performance of advanced systes are evaluated.
NASA Technical Reports Server (NTRS)
Csank, Jeffrey T.; Stueber, Thomas J.
2013-01-01
A dual flow-path inlet system is being tested to evaluate methodologies for a Turbine Based Combined Cycle (TBCC) propulsion system to perform a controlled inlet mode transition. Prior to experimental testing, simulation models are used to test, debug, and validate potential control algorithms. One simulation package being used for testing is the High Mach Transient Engine Cycle Code simulation, known as HiTECC. This paper discusses the closed loop control system, which utilizes a shock location sensor to improve inlet performance and operability. Even though the shock location feedback has a coarse resolution, the feedback allows for a reduction in steady state error and, in some cases, better performance than with previous proposed pressure ratio based methods. This paper demonstrates the design and benefit with the implementation of a proportional-integral controller, an H-Infinity based controller, and a disturbance observer based controller.
NASA Astrophysics Data System (ADS)
Li, Xiao; Tian, Xiaodong; Yang, Tao; Wang, Wei; Song, Yan; Guo, Quangui; Liu, Zhanjun
2018-05-01
Inferior cycling stability and rate performance respectively caused by rigorous volume change and poor electrical conductivity were the main challenge of state-of-the-art Silicon-based electrode. In this work, silylated functionalized exfoliated graphite oxide (EGO)/silicon@amorphous carbon (3-APTS-EGO/Si@C) was synthesized by adopting silane as intermediate to connect Si particles with EGO sheets followed by introduction of amorphous carbon. The result suggested that 3-Aminopropyltriethoxysilan connected the EGO sheets and Si nanoparticles via covalent bonds. Owing to the strong covalent interaction and the synergistic effect between the silicon, EGO sheets and amorphous carbon, 3-APTS-EGO/Si@C composite possessed a high capacity of 774 mAh g-1 even after 450 cycles at 0.4 A g-1 with the retention capacity of 97%. This work also provided an effective strategy to improve the long cycling life performance of Si-based electrode.
An improved turbine disk design to increase reliability of aircraft jet engines
NASA Technical Reports Server (NTRS)
Barack, W. N.; Domas, P. A.
1976-01-01
An analytical study was performed on a novel disk design to replace the existing high-pressure turbine, stage 1 disk on the CF6-50 turbofan engine. Preliminary studies were conducted on seven candidate disk design concepts. An integral multidisk design with bore entry of the turbine blade cooling air was selected as the improved disk design. This disk has the unique feature of being redundant such that if one portion of the disk would fail, the remaining portion would prevent the release of large disk fragments from the turbine system. Low cycle fatigue lives, initial defect propagation lives, burst speed, and the kinetic energies of probable disk fragment configurations were calculated, and comparisons were made with the existing disk, both in its current material, IN 718, and with the substitution of an advanced alloy, Rene 95. The design for redundancy approach which necessitated the addition of approximately 44.5 kg (98 lb) to the design disk substantially improved the life of the disk. The life to crack initiation was increased from 30,000 cycles to more than 100,000 cycles. The cycles to failure from initial defect propagation were increased from 380 cycles to 1564 cycles. Burst speed was increased from 126 percent overspeed to 149 percent overspeed. Additionally, the maximum fragment energies associated with a failure were decreased by an order of magnitude.
Validation test of advanced technology for IPV nickel-hydrogen flight cells - Update
NASA Technical Reports Server (NTRS)
Smithrick, John J.; Hall, Stephen W.
1992-01-01
Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the LEO cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion.
Improvements in the efficiency of turboexpanders in cryogenic applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agahi, R.R.; Lin, M.C.; Ershaghi, B.
1996-12-31
Process designers have utilized turboexpanders in cryogenic processes because of their higher thermal efficiencies when compared with conventional refrigeration cycles. Process design and equipment performance have improved substantially through the utilization of modern technologies. Turboexpander manufacturers have also adopted Computational Fluid Dynamic Software, Computer Numerical Control Technology and Holography Techniques to further improve an already impressive turboexpander efficiency performance. In this paper, the authors explain the design process of the turboexpander utilizing modern technology. Two cases of turboexpanders processing helium (4.35{degrees}K) and hydrogen (56{degrees}K) will be presented.
NASA Astrophysics Data System (ADS)
Shen, X.; Chen, T.; Bishop, S. R.; Perry, N. H.; Tuller, H. L.; Sasaki, K.
2017-12-01
Oxide anodes composed of 60 wt% Gd0.1Ce0.8Ni0.1O2 (GDCN)- 40 wt% (Sr0.9La0.1)0.9Ti0.9Ni0.1O3 (SLTN) composites were prepared and tested on (ZrO2)0.89(Sc2O3)0.1(CeO2)0.01 (SSZ) electrolyte-supported SOFC cells utilizing a (La0.75Sr0.25)0.98MnO3 (LSM)-SSZ cathode, in 3%-humidified hydrogen fuel at 800 °C. Improved electrochemical performance was found compared to the cell using Ni-free 60 wt% Gd0.1Ce0.9O2 (GDC) - 40 wt % Sr0.9La0.1TiO3 (SLT) that was attributed to the exsolution of nano-sized Ni particles from the Ni-doped system. This exsolution process represents a simpler, more attractive method to improve performance than the more conventional but more complicated infiltration method for introducing catalytic nanoparticles. Redox cycling testing was performed to investigate the performance and structural stability of the Ni-doped GDC-SLT anode. The results indicated that the Ni exsolution and aggregation occurred while redox cycling proceeded, resulting in a gradually reduced anodic overvoltage. Symmetric cells with dense thin film Gd0.1Ce0.9-xNixO2 (x = 0, 0.05, 0.1, 0.15) electrodes were also tested, demonstrating lower area-specific resistances with increasing Ni content on the surface under reducing conditions. The steady improvement during redox cycling, despite Ni agglomeration, is related to the continuous increase in the overall Ni content on the anode surface, which may be enabled by kinetic limitations to Ni re-dissolving under oxidizing transients.
Tools for Measuring and Improving Performance.
ERIC Educational Resources Information Center
Jurow, Susan
1993-01-01
Explains the need for meaningful performance measures in libraries and the Total Quality Management (TQM) approach to data collection. Five tools representing different stages of a TQM inquiry are covered (i.e., the Shewhart Cycle, flowcharts, cause-and-effect diagrams, Pareto charts, and control charts), and benchmarking is addressed. (Contains…
The Human Resource Cycle as Basis of Human Resource Development System.
ERIC Educational Resources Information Center
Jereb, Janez
The primary aim of human-resource-development systems in companies is to improve organizational performance through satisfying the development needs of individual employees. This paper presents findings of a study that looked at how human-resource-development systems worked in practice, in particular, how performance management, selection,…
García-Pinillos, Felipe; Cámara-Pérez, Jose C; Soto-Hermoso, Víctor M; Latorre-Román, Pedro Á
2017-01-01
García-Pinillos, F, Cámara-Pérez, JC, Soto-Hermoso, VM, and Latorre-Román, PÁ. A High Intensity Interval Training (HIIT)-based running plan improves athletic performance by improving muscle power. J Strength Cond Res 31(1): 146-153, 2017-This study aimed to examine the effect of a 5-week high-intensity intermittent training (HIIT)-based running plan on athletic performance and to compare the physiological and neuromuscular responses during a sprint-distance triathlon before and after the HIIT period. Thirteen triathletes were matched into 2 groups: the experimental group (EG) and the control group (CG). The CG was asked to maintain their normal training routines, whereas the EG maintained only their swimming and cycling routines and modified their running routine. Participants completed a sprint-distance triathlon before (pretest) and after (posttest) the intervention period. In both pretest and posttest, the participants performed 4 jumping tests: before the race (baseline), postswim, postcycling, and postrun. Additionally, heart rate was monitored (HRmean), whereas rate of perceived exertion (RPE) and blood lactate accumulation (BLa) were registered after the race. No significant differences (p ≥ 0.05) between groups were found before HIIT intervention (at pretest). Significant group-by-training interactions were found in vertical jumping ability and athletic performance: the EG improved jumping performance (∼6-9%, p ≤ 0.05, effect size (ES) > 0.7), swimming performance (p = 0.013, ES = 0.438), and running time (p = 0.001, ES = 0.667) during the competition, whereas the CG remained unchanged (p ≥ 0.05, ES < 0.4). No changes (p ≥ 0.05, ES < 0.4) were observed in RPE, HRmean, and BLa. A linear regression analysis showed that ΔCMJ predicted both the ΔRu_time (R = 0.559; p = 0.008) and the ΔOverall_time (R = 0.391; p = 0.048). This low-volume, HIIT-based running plan combined with the high training volumes of these triathletes in swimming and cycling improved athletic performance during a sprint-distance triathlon. This improvement may be due to improved neuromuscular characteristics that were transferred into improved muscle power and work economy.
Wood, Simon; Quinn, Alison; Troupe, Stephen; Kingsland, Charles; Lewis-Jones, Iwan
2006-12-01
The effect of seasonality and daylight length on mammalian reproduction leading to spring births has been well established, and is known as photoperiodism. In assisted reproduction there is much greater uncertainty as to the effect of seasonality. This was a 4-year retrospective analysis of 2709 standardised cycles of IVF/ICSI. Data was analysed with regard to the 1642 cycles occurring during the months of extended daylight (Apr-Sept) and those 1067 cycles during winter months of restricted light length (Oct-Mar). The results showed that there was significant improvement in assisted conception outcomes in cycles performed in summer (lighter) months with more efficient ovarian stimulation 766iu v880iu/per oocyte retrieved (p=0.006). There was similarly a significantly improved implantation rate per embryo transferred 11.42% vs 9.35% (p=0.011) and greater clinical pregnancy rate 20% vs 15% (p=0.0033) during summer cycles. This study appears to demonstrate a significant benefit of increased daylight length on outcomes of IVF/ICSI cycles. Whilst the exact mechanism of this is unclear, it would seem probable that melatonin may have actions at multiple sites and on multiple levels of the reproductive tract, and may exert a more profound effect on outcomes of assisted conception cycles than has been previously considered.
Cho, Jay; Freivalds, Andris; Rovniak, Liza S.
2017-01-01
This study investigated the feasibility of using a desk bike in an office setting. Workstation measurements were introduced to accommodate 95% of the general U.S. population in using desk bikes. Reading and typing performances were compared at three different cycling conditions (no cycling, 10 and 25 watts). Thirty healthy individuals (15 female and 15 male; Age mean: 23.1, σ: 4.19) were recruited based on 5/50/95th percentile stature. Participants were required to select preferred workstation settings and perform reading and typing tasks while pedaling. According to anthropometric measurements and variability from user preference, recommended adjustable ranges of workstation settings for the general U.S. population were derived. Repeated measures ANOVA showed that pedaling had no significant effect on reading comprehension (p > .05), but had significant effect on typing performance (p < .001). A preferred level of cycling intensity was determined (mean 17.3 watts, σ: 3.69). PMID:28166871
NASA Astrophysics Data System (ADS)
Wang, Rui; Feng, Lili; Yang, Wenrong; Zhang, Yinyin; Zhang, Yanli; Bai, Wei; Liu, Bo; Zhang, Wei; Chuan, Yongming; Zheng, Ziguang; Guan, Hongjin
2017-10-01
When testing the electrochemical performance of metal oxide anode for lithium-ion batteries (LIBs), binder played important role on the electrochemical performance. Which binder was more suitable for preparing transition metal oxides anodes of LIBs has not been systematically researched. Herein, five different binders such as polyvinylidene fluoride (PVDF) HSV900, PVDF 301F, PVDF Solvay5130, the mixture of styrene butadiene rubber and sodium carboxymethyl cellulose (SBR+CMC), and polyacrylonitrile (LA133) were studied to make anode electrodes (compared to the full battery). The electrochemical tests show that using SBR+CMC and LA133 binder which use water as solution were significantly better than PVDF. The SBR+CMC binder remarkably improve the bonding capacity, cycle stability, and rate performance of battery anode, and the capacity retention was about 87% after 50th cycle relative to the second cycle. SBR+CMC binder was more suitable for making transition metal oxides anodes of LIBs.
NASA Astrophysics Data System (ADS)
Chen, Xianhe; Xia, Zhixun; Huang, Liya; Hu, Jianxin
2017-05-01
The working cycle of a novel underwater propulsion system based on aluminium combustion with water is researched in order to evaluate the best performance. The system exploits the exothermic reaction between aluminium and water which will produce high temperature, pressure steam and hydrogen mixture that can be used to drive turbine to generate power. Several new system configurations corresponding to different working cycles are investigated, and their performance parameters in terms of net power, energy density and global efficiency are discussed. The results of the system simulation show that using the recirculation steam rather than hydrogen as the carrier gas, the system net power, energy density and efficiency of the system are greatly increased compared, however the system performance is close either using adiabatic compression or isothermal compression. And if an evaporator component is added into system in order to take full use of the solid product heat, the system performance will be improved.
NASA Astrophysics Data System (ADS)
Aklalouch, Mohamed; Amarilla, José Manuel; Rojas, Rosa M.; Saadoune, Ismael; Rojo, José María
LiCr 2 YNi 0.5- YMn 1.5- YO 4 (0 < Y ≤ 0.2) spinels have been synthesized by a sucrose-aided combustion method. Two sets of Cr-doped samples have been obtained by heating the "as-prepared" samples at 700 and 900 °C for 1 h. X-ray diffraction and thermogravimetric data show that pure and single phase spinels with similar lattice parameter have been synthesized. The homogeneity and the sub-micrometric particle size of the spinels have been shown by SEM and TEM. The main effect of the temperature is to increase the particle size from ≈50 to ≈500 nm, on heating from 700 to 900 °C. The study of the influence of Cr-dopant content and thermal treatment on the electrochemical properties at 25 °C and at 55 °C has been carried out by galvanostatic cycling in Li-cells. The discharge capacity (≈130 mAh g -1) does not noticeably change with the synthesis conditions; but the cycling performances are strongly modified. Key factors that control the cycling performances have been determined. The most highlighted result is that spinels heated at 900 °C with Y ≤ 0.1 have very high capacity retention at 55 °C (>96% after 40 cycles, cyclability >99.9% by cycle) indicating that metal doping is a new approach to prepare 5 V LiNi 0.5Mn 1.5O 5-based cathodes with excellent cycling performances at high temperature.
NASA Lewis advanced IPV nickel-hydrogen technology
NASA Technical Reports Server (NTRS)
Smithrick, John J.; Britton, Doris L.
1993-01-01
Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts. Some of the advancements are as follows: to use 26 percent potassium hydroxide electrolyte to improve cycle life and performance, to modify the state of the art cell design to eliminate identified failure modes and further improve cycle life, and to develop a lightweight nickel electrode to reduce battery mass, hence reduce launch and/or increase satellite payload. A breakthrough in the LEO cycle life of individual pressure vessel nickel-hydrogen battery cells was reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 accelerated LEO cycles at 80 percent DOD compared to 3,500 cycles for cells containing 31 percent KOH. Results of the boiler plate cell tests have been validated at NWSC, Crane, Indiana. Forty-eight ampere-hour flight cells containing 26 and 31 percent KOH have undergone real time LEO cycle life testing at an 80 percent DOD, 10 C. The three cells containing 26 percent KOH failed on the average at cycle 19,500. The three cells containing 31 percent KOH failed on the average at cycle 6,400. Validation testing of NASA Lewis 125 Ah advanced design IPV nickel-hydrogen flight cells is also being conducted at NWSC, Crane, Indiana under a NASA Lewis contract. This consists of characterization, storage, and cycle life testing. There was no capacity degradation after 52 days of storage with the cells in the discharged state, on open circuit, 0 C, and a hydrogen pressure of 14.5 psia. The catalyzed wall wick cells have been cycled for over 22,694 cycles with no cell failures in the continuing test. All three of the non-catalyzed wall wick cells failed (cycles 9,588; 13,900; and 20,575). Cycle life test results of the Fibrex nickel electrode has demonstrated the feasibility of an improved nickel electrode giving a higher specific energy nickel-hydrogen cell. A nickel-hydrogen boiler plate cell using an 80 mil thick, 90 percent porous Fibrex nickel electrode has been cycled for 10,000 cycles at 40 percent DOD.
Rosa, João Paulo P; Silva, Andressa; Rodrigues, Dayane F; Simim, Mário Antônio; Narciso, Fernanda V; Tufik, Sergio; Bichara, Jorge J; Pereira, Sebastian Rafael D; Da Silva, Sidney C; de Mello, Marco Tulio
2018-04-16
This study investigated the effect of using an artificial bright light on the entrainment of the sleep/wake cycle as well as the reaction times of athletes before the Rio 2016 Olympic Games. A total of 22 athletes from the Brazilian Olympic Swimming Team were evaluated, with the aim of preparing them to compete at a time when they would normally be about to go to bed for the night. During the 8-day acclimatization period, their sleep/wake cycles were assessed by actigraphy, with all the athletes being treated with artificial light therapy for between 30 and 45 min (starting at day 3). In addition, other recommendations to improve sleep hygiene were made to the athletes. In order to assess reaction times, the Psychomotor Vigilance Test was performed before (day 1) and after (day 8) the bright light therapy. As a result of the intervention, the athletes slept later on the third (p = 0.01), seventh (p = 0.01) and eighth (p = 0.01) days after starting bright light therapy. Regarding reaction times, when tested in the morning the athletes showed improved average (p = 0.01) and minimum reaction time (p = 0.03) when comparing day 8 to day 1. When tested in the evening, they showed improved average (p = 0.04), minimum (p = 0.03) and maximum reaction time (p = 0.02) when comparing day 8 to day 1. Light therapy treatment delayed the sleep/wake cycles and improved reaction times of members of the swimming team. The use of bright light therapy was shown to be effective in modulating the sleep/wake cycles of athletes who had to perform in competitions that took place late at night.
Resveratrol Improves Cell Cycle Arrest in Chronic Prostatitis Rats, by C-kit/SCF Suppression.
He, Yi; Zeng, Huizhi; Yu, Yang; Zhang, Jiashu; Zeng, Xiaona; Gong, Fengtao; Liu, Qi; Yang, Bo
2017-08-01
Chronic prostatitis (CP) with complex pathogenesis is difficult for treatment. c-kit has been associated with the control of cell proliferation of prostate cells. This study aims to evaluate the role of resveratrol, an activator of Sirt1, in regulating the expression of c-kit in CP and investigate the consequent effects on cell cycle. Rat model of CP was established through subcutaneous injections of diphtheria-pertussis-tetanus vaccine and subsequently treated with resveratrol. Hematoxylin and eosin staining was performed to identify the histopathological changes in prostates. Western blotting and immunohistochemical staining examined the expression level of c-kit, stem cell factor (SCF), Sirt1, and cell cycle-associated proteins. The model group exhibited severe diffuse chronic inflammation, characterized by leukocyte infiltration and papillary frond protrusion into the gland cavities, and a notable increase in prostatic epithelial height. Gland lumen diameter was also significantly smaller; the activity of c-kit/SCF in the CP rats was increased significantly compared to the control group. Meanwhile, the cell cycle proteins are dysregulated significantly in CP rats. Resveratrol treatment significantly improved these factors by Sirt1 activation. Dysregulation of cell cycle was involved in the pathological processes of CP, which was improved after resveratrol treatment by the downregulation of c-kit/SCF by activating Sirt1.
NASA Astrophysics Data System (ADS)
Latief, Y.; Berawi, M. A.; Koesalamwardi, A. B.; Supriadi, L. S. R.
2018-03-01
Near Zero Energy House (NZEH) is a housing building that provides energy efficiency by using renewable energy technologies and passive house design. Currently, the costs for NZEH are quite expensive due to the high costs of the equipment and materials for solar panel, insulation, fenestration and other renewable energy technology. Therefore, a study to obtain the optimum design of a NZEH is necessary. The aim of the optimum design is achieving an economical life cycle cost performance of the NZEH. One of the optimization methods that could be utilized is Genetic Algorithm. It provides the method to obtain the optimum design based on the combinations of NZEH variable designs. This paper discusses the study to identify the optimum design of a NZEH that provides an optimum life cycle cost performance using Genetic Algorithm. In this study, an experiment through extensive design simulations of a one-level house model was conducted. As a result, the study provide the optimum design from combinations of NZEH variable designs, which are building orientation, window to wall ratio, and glazing types that would maximize the energy generated by photovoltaic panel. Hence, the design would support an optimum life cycle cost performance of the house.
Advanced nickel-metal hydride cell development. Final report, September 1993--March 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Hong S.
1996-03-01
Inert gas atomization using metal hydride alloys for a Ni/MH{sub x}cell was studied. Atomization of the alloys was demonstrated on a small production scale up to batch size of several kg. Relative performance of the atomized and nonatomized alloys was investigated for the electrode material in a Ni/MH{sub x} cell. The study included effects of charge-discharge rates, temperature, and particle size on cell voltage (polarization) and specific capacity. Results show that the specific capacity of the present atomized alloys was apprecialy smaller than that of the nonatomized powder, especially for initial cycles. Full activation of the atomized alloys oftentook severalmore » hundreds of cycles. However, no appreciable difference in discharge rate capability was observed with R10 and R12 alloys. Chemical compositions were indistinguishable, although the oxygen contents of the atomized alloys were always higher. Effects of Ni and Cu coating on alloy performance were studied after electroless coating; the coatings noticeably improved the electrode rate capability for all the alloys. The electrode polarization was esecially improved, but not the cycle life. Further studies are needed.« less
NASA Astrophysics Data System (ADS)
Liu, Hui; Zou, Yongjin; Huang, Liyan; Yin, Hao; Xi, Chengqiao; Chen, Xin; Shentu, Hongwei; Li, Chao; Zhang, Jingjing; Lv, ChunJu; Fan, Meiqiang
2018-06-01
Sandwich-structured carbon nanotubes, silicon oxide, and polyaniline (hereafter denoted as CNTs/SiOx/PANI) were prepared by combining a sol-gel method, magnesiothermic reduction at 250 °C, and chemical oxidative polymerization. The CNTs, SiOx and PANI in the composite was 16 wt%, 51 wt% and 33 wt%, respectively. The CNTs/SiOx/PANI electrodes exhibited excellent cycle and high-rate performance as anodes in Li-ion batteries, including charge/discharge capacities of 1156/1178 mAh g-1 after 60 cycles at 0.2 A g-1 current density and 728/725 mAh g-1 at 8 A g-1 current density. The improvement was due to the synergy between CNTs and PANI. The SiOx scattered on the CNTs core and coated by PANI improved its conductivity and accommodated the volume change during repeated lithiation/delithiation cycles. This simple synthesis provided a scalable route for the large-scale production of CNTs/SiOx/PANI nanostructures, with various applications such as in Li-ion batteries.
The effect of altitude on cycling performance: a challenge to traditional concepts.
Hahn, A G; Gore, C J
2001-01-01
Acute exposure to moderate altitude is likely to enhance cycling performance on flat terrain because the benefit of reduced aerodynamic drag outweighs the decrease in maximum aerobic power [maximal oxygen uptake (VO2max)]. In contrast, when the course is mountainous, cycling performance will be reduced at moderate altitude. Living and training at altitude, or living in an hypoxic environment (approximately 2500 m) but training near sea level, are popular practices among elite cyclists seeking enhanced performance at sea level. In an attempt to confirm or refute the efficacy of these practices, we reviewed studies conducted on highly-trained athletes and, where possible, on elite cyclists. To ensure relevance of the information to the conditions likely to be encountered by cyclists, we concentrated our literature survey on studies that have used 2- to 4-week exposures to moderate altitude (1500 to 3000 m). With acclimatisation there is strong evidence of decreased production or increased clearance of lactate in the muscle, moderate evidence of enhanced muscle buffering capacity (beta m) and tenuous evidence of improved mechanical efficiency (ME) of cycling. Our analysis of the relevant literature indicates that, in contrast to the existing paradigm, adaptation to natural or simulated moderate altitude does not stimulate red cell production sufficiently to increase red cell volume (RCV) and haemoglobin mass (Hb(mass)). Hypoxia does increase serum erthyropoietin levels but the next step in the erythropoietic cascade is not clearly established; there is only weak evidence of an increase in young red blood cells (reticulocytes). Moreover, the collective evidence from studies of highly-trained athletes indicates that adaptation to hypoxia is unlikely to enhance sea level VO2max. Such enhancement would be expected if RCV and Hb(mass) were elevated. The accumulated results of 5 different research groups that have used controlled study designs indicate that continuous living and training at moderate altitude does not improve sea level performance of high level athletes. However, recent studies from 3 independent laboratories have consistently shown small improvements after living in hypoxia and training near sea level. While other research groups have attributed the improved performance to increased RCV and VO2max, we cite evidence that changes at the muscle level (beta m and ME) could be the fundamental mechanism. While living at altitude but training near sea level may be optimal for enhancing the performance of competitive cyclists, much further research is required to confirm its benefit. If this benefit does exist, it probably varies between individuals and averages little more than 1%.
Ma, Lianbo; Chen, Renpeng; Hu, Yi; Zhu, Guoyin; Chen, Tao; Lu, Hongling; Liang, Jia; Tie, Zuoxiu; Jin, Zhong; Liu, Jie
2016-10-20
To improve the energy storage performance of carbon-based materials, considerable attention has been paid to the design and fabrication of novel carbon architectures with structural and chemical modifications. Herein, we report that hierarchical porous nitrogen-rich carbon (HPNC) nanospheres originating from acidic etching of metal carbide/carbon hybrid nanoarchitectures can be employed as high-performance anode materials for both lithium-ion batteries (LIBs) and sodium-ion batteries (SIBs). The structural advantages of HPNC nanospheres are that the exceptionally-high content of nitrogen (17.4 wt%) can provide abundant electroactive sites and enlarge the interlayer distance (∼3.5 Å) to improve the capacity, and the large amount of micropores and mesopores can serve as reservoirs for storing lithium/sodium ions. In LIBs, HPNC based anodes deliver a high reversible capacity of 1187 mA h g -1 after 100 cycles at 100 mA g -1 , a great rate performance of 470 mA h g -1 at 5000 mA g -1 , and outstanding cycling stabilities with a capacity of 788 mA h g -1 after 500 cycles at 1000 mA g -1 . In SIBs, HPNC based anodes exhibit a remarkable reversible capacity of 357 mA h g -1 at 100 mA g -1 and high long-term stability with a capacity of 136 mA h g -1 after 500 cycles at 1000 mA g -1 .
Effect of caffeine on cycling time-trial performance in the heat.
Pitchford, Nathan W; Fell, James W; Leveritt, Michael D; Desbrow, Ben; Shing, Cecilia M
2014-07-01
The purpose of this investigation was to determine whether a moderate dose of caffeine would improve a laboratory simulated cycling time-trial in the heat. Nine well-trained male subjects (VO2max 64.4±6.8mLmin(-1)kg(-1), peak power output 378±40W) completed one familiarisation and two experimental laboratory simulated cycling time-trials in environmental conditions of 35°C and 25% RH 90min after consuming either caffeine (3mgkg(-1) BW) or placebo, in a double blind, cross-over study. Time-trial performance was faster in the caffeine trial compared with the placebo trial (mean±SD, 3806±359s versus 4079±333s, p=0.06, 90%CI 42-500s, 86% likelihood of benefit, d=-0.79). Caffeine ingestion was associated with small to moderate increases in average heart rate (p=0.178, d=0.39), VO2 (p=0.154, d=0.45), respiratory exchange ratio (p=0.292, d=0.35) and core temperature (p=0.616, d=0.22) when compared to placebo, however, these were not statistically significant. Average RPE during the caffeine supplemented time-trial was not significantly different from placebo (p=0.41, d=-0.13). Caffeine supplementation at 3mgkg(-1) BW resulted in a worthwhile improvement in cycling time-trial performance in the heat. Double-blind cross-over study. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Ai, Yuanfei; Geng, Xuewen; Lou, Zheng; Wang, Zhiming M; Shen, Guozhen
2015-11-04
Effectively composite materials with optimized structures exhibited promising potential in continuing improving the electrochemical performances of supercapacitors in the past few years. Here, we proposed a rational design of branched CoMoO4@CoNiO2 core/shell nanowire arrays on Ni foam by two steps of hydrothermal processing. Owing to the high activity of the scaffold-like CoMoO4 nanowires and the well-defined CoNiO2 nanoneedles, the three-dimensional (3D) electrode architectures achieved remarkable electrochemical performances with high areal specific capacitance (5.31 F/cm(2) at 5 mA/cm(2)) and superior cycling stability(159% of the original specific capacitance, i.e., 95.7% of the maximum retained after 5000 cycles at 30 mA/cm(2)). The all-solid-state asymmetric supercapacitors composed of such electrode and activated carbon (AC) exhibited an areal specific capacitance of 1.54 F/cm(2) at 10 mA/cm(2) and a rate capability (59.75 Wh/kg at a 1464 W/kg) comparable with Li-ion batteries. It also showed an excellent cycling stability with no capacitance attenuation after 50000 cycles at 100 mA/cm(2). After rapid charging (1 s), such supercapacitors in series could lighten a red LED for a long time and drive a mini motor effectively, demonstrating advances in energy storage, scalable integrated applications, and promising commercial potential.
USDA-ARS?s Scientific Manuscript database
Inbred progeny recurrent selection was shown to be superior to several forms of outbred-progeny recurrent selection for improving population per se performance based on theoretical arguments. However, recent improvements to theory and mounting empirical evidence suggest that inbred-progeny recurren...
Toward an Improved Method of HSI Evaluation in Defense Acquisition
2006-12-01
29 C. AN EXAMPLE: EXPRESSING THE DOMAINS OF HSI IN TERMS OF LIFE-CYCLE COSTS ................................................................... 30...Edit Parameter’ (A) and ‘Edit Interaction’ (B). . 38 Figure 13. HSI slider tool concept (From http://Kn.gd- ais.com/ASPs/ eLearning /HSI_Sliders...focusing on the human element of a system is the most likely method for increasing system performance and reducing system life-cycle costs (Booher
Evaluation program for secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Christy, D. E.; Harkness, J. D.
1973-01-01
A life cycle test of secondary electric batteries for spacecraft applications was conducted. A sample number of nickel cadmium batteries were subjected to general performance tests to determine the limit of their actual capabilities. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of spacecraft batteries. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is provided.
NASA Astrophysics Data System (ADS)
Lee, Dong Kyu; Ahn, Chi Won; Jeon, Hwan-Jin
2017-08-01
Graphitic carbon fiber felt (GCFF) with a crystalline graphitic carbon structure was facilely prepared by a combination of electrospinning and graphitization (2800 °C heat treatment) and was used as an interlayer between the cathode and separator in Li-S batteries. This GCFF interlayer trapped the polysulfides on the cathode side and increased the utilization of sulfur by suppressing the shuttle phenomenon. Also, the GCFF was shown to be able to act as an upper current collector to reduce the charge-transfer resistance owing to the high crystallinity of the graphitic carbon fibers. The sulfur cathode with the GCFF interlayer showed a high specific initial discharge capacity of 1280.14 mAh g-1 and excellent cycling stability (1004.62 mAh g-1 after 100 cycles) at 0.2 C. Also, an image of the glass fiber (GF) separator on the anode side confirmed the presence of an SEI after 200 cycles, which apparently resulted from stable Li deposition on the Li metal because of the low or medium concentration of sulfur in the electrolyte solution. Our observations should contribute to elucidating the key features of complex three-dimensional carbon fabrics with crystalline graphitic structures that allow them, when inserted as interlayers, to markedly improve the performance of rechargeable batteries.
Life cycle assessment of molten carbonate fuel cells: State of the art and strategies for the future
NASA Astrophysics Data System (ADS)
Mehmeti, Andi; Santoni, Francesca; Della Pietra, Massimiliano; McPhail, Stephen J.
2016-03-01
This study aims to review and provide an up to date international life cycle thinking literature with particular emphasis on life cycle assessment (LCA), applied to Molten Carbonate Fuel Cells (MCFCs), a technology forcefully entering the field of decentralized heat and power generation. Critical environmental issues, comparison of results between studies and improvement strategies are analyzed and highlighted. The findings stress that MCFC environmental performance is heavily influenced by the current use of non-renewable energy and high material demand of rare minerals which generate high environmental burdens in the manufacturing stage, thereby confirming the prominent role of these processes in a comprehensive LCA study. The comparison of operational phases highlights that MCFCs are robust and able to compete with other mature technologies contributing substantially to airborne emissions reduction and promoting a switch to renewable fuels, however, further progress and market competitiveness urges adoption of an eco-efficiency philosophy to forge the link between environmental and economic concerns. Adopting a well-organized systematic research driven by life cycle models and eco-efficiency principles stakeholders will glean valuable information to make well balanced decisions for improving performance towards the concept 'producing more quality with less resources' and accelerate market penetration of the technology.
Ma, Ruifang; Fan, Ling; Chen, Suhua; Wei, Zengxi; Yang, Yuhua; Yang, Hongguan; Qin, Yong; Lu, Bingan
2018-05-09
Sodium dual-ion batteries (NDIBs) are attracting extensive attention recently because of their low cost and abundant sodium resources. However, the low capacity of the carbonaceous anode would reduce the energy density, and the formation of the solid-electrolyte interphase (SEI) in the anode during the initial cycles will lead to large amount consumption of Na + in the electrolyte, which results in low Coulombic efficiency and inferior stability of the NDIBs. To address these issues, a phosphorus-doped soft carbon (P-SC) anode combined with a presodiation process is developed to enhance the performance of the NDIBs. The phosphorus atom doping could enhance the electric conductivity and further improve the sodium storage property. On the other hand, an SEI could preform in the anode during the presodiation process; thus the anode has no need to consume large amounts of Na + to form the SEI during the cycling of the NDIBs. Consequently, the NDIBs with P-SC anode after the presodiation process exhibit high Coulombic efficiency (over 90%) and long cycle stability (81 mA h g -1 at 1000 mA g -1 after 900 cycles with capacity retention of 81.8%), far more superior to the unsodiated NDIBs. This work may provide guidance for developing high performance NDIBs in the future.
Production of Caproic Acid from Mixed Organic Waste: An Environmental Life Cycle Perspective
2017-01-01
Caproic acid is an emerging platform chemical with diverse applications. Recently, a novel biorefinery process, that is, chain elongation, was developed to convert mixed organic waste and ethanol into renewable caproic acids. In the coming years, this process may become commercialized, and continuing to improve on the basis of numerous ongoing technological and microbiological studies. This study aims to analyze the environmental performance of caproic acid production from mixed organic waste via chain elongation at this current, early stage of technological development. To this end, a life cycle assessment (LCA) was performed to evaluate the environmental impact of producing 1 kg caproic acid from organic waste via chain elongation, in both a lab-scale and a pilot-scale system. Two mixed organic waste were used as substrates: the organic fraction of municipal solid waste (OFMSW) and supermarket food waste (SFW). Ethanol use was found to be the dominant cause of environmental impact over the life cycle. Extraction solvent recovery was found to be a crucial uncertainty that may have a substantial influence on the life-cycle impacts. We recommend that future research and industrial producers focus on the reduction of ethanol use in chain elongation and improve the recovery efficiency of the extraction solvent. PMID:28513150
NASA Technical Reports Server (NTRS)
Jaffe, Leonard D.
1988-01-01
This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.
Improving the rates of electronic results acknowledgement at a tertiary eye care centre.
Phua, Val; Au, Benjamin; Soh, Yu Qiang; Husain, Rahat
2017-01-01
Hundreds of thousands of tests are performed annually in hospitals worldwide. Safety Issues arise when abnormal results are not recognized promptly resulting in delayed treatment and increased morbidity and mortality. As a result Singapore's largest healthcare group, Singhealth introduced an electronic result acknowledgement system. This system was adopted by the Singapore National Eye Centre (SNEC) in February 2016. Baseline measurements show that weekly numbers of unacknowledged results ranged from 193 to 617. The current standards of electronic results acknowledgement posts a significant patient safety hazard. Root cause analysis was performed to identify contributory factors. Pareto principle was then used by the authors to identify the main contributory factors. We employed the rapid cycle improvement Plan-do-study-act (PDSA) strategy to test and evaluate implemented changes. Changes are implemented for 2 weeks and data collected prospectively. The data is analyzed the week after and the following PDSA actions are decided and instituted the following week. 3 PDSA cycles were undertaken in total. The first PDSA cycle focused on raising awareness of the problem at hand, the number of unacknowledged results drastically decreased during the 1 st week of implementation of our PDSA from 617 to 254. The second PDSA cycle targeted the lack of knowledge of doctors involved in the electronic result acknowledgement process. There was a trend downwards near the end of the cycle which continued through the week after. The third PDSA cycle targeted individual doctors and provided individual remedial training. Second line doctors were also equipped to better handle abnormal results. There was significant improvement with the number of unacknowledged abnormal results dropping to <5 a week. Multiple factors were identified to contribute to the low compliance to electronic acknowledgement of results. The role doctors play in the issue at hand was paramount and required careful handling in a professional manner with multiple reminders and emphasis on the importance of acknowledging and acting on the results.A significant improvement in the rates of acknowledgement of abnormal results was demonstrated with clear benefits to patient safety. Interventions can be replicated when implementing similar systems to other areas of healthcare.
Improving the rates of electronic results acknowledgement at a tertiary eye care centre
Phua, Val; Au, Benjamin; Soh, Yu Qiang; Husain, Rahat
2017-01-01
Background Hundreds of thousands of tests are performed annually in hospitals worldwide. Safety Issues arise when abnormal results are not recognized promptly resulting in delayed treatment and increased morbidity and mortality. As a result Singapore’s largest healthcare group, Singhealth introduced an electronic result acknowledgement system. This system was adopted by the Singapore National Eye Centre (SNEC) in February 2016. Baseline measurements show that weekly numbers of unacknowledged results ranged from 193 to 617. The current standards of electronic results acknowledgement posts a significant patient safety hazard. Methods Root cause analysis was performed to identify contributory factors. Pareto principle was then used by the authors to identify the main contributory factors. We employed the rapid cycle improvement Plan-do-study-act (PDSA) strategy to test and evaluate implemented changes. Changes are implemented for 2 weeks and data collected prospectively. The data is analyzed the week after and the following PDSA actions are decided and instituted the following week. 3 PDSA cycles were undertaken in total. Results The first PDSA cycle focused on raising awareness of the problem at hand, the number of unacknowledged results drastically decreased during the 1stweek of implementation of our PDSA from 617 to 254. The second PDSA cycle targeted the lack of knowledge of doctors involved in the electronic result acknowledgement process. There was a trend downwards near the end of the cycle which continued through the week after. The third PDSA cycle targeted individual doctors and provided individual remedial training. Second line doctors were also equipped to better handle abnormal results. There was significant improvement with the number of unacknowledged abnormal results dropping to <5 a week. Conclusions Multiple factors were identified to contribute to the low compliance to electronic acknowledgement of results. The role doctors play in the issue at hand was paramount and required careful handling in a professional manner with multiple reminders and emphasis on the importance of acknowledging and acting on the results.A significant improvement in the rates of acknowledgement of abnormal results was demonstrated with clear benefits to patient safety. Interventions can be replicated when implementing similar systems to other areas of healthcare. PMID:29450290
Reliability and Productivity Modeling for the Optimization of Separated Spacecraft Interferometers
NASA Technical Reports Server (NTRS)
Kenny, Sean (Technical Monitor); Wertz, Julie
2002-01-01
As technological systems grow in capability, they also grow in complexity. Due to this complexity, it is no longer possible for a designer to use engineering judgement to identify the components that have the largest impact on system life cycle metrics, such as reliability, productivity, cost, and cost effectiveness. One way of identifying these key components is to build quantitative models and analysis tools that can be used to aid the designer in making high level architecture decisions. Once these key components have been identified, two main approaches to improving a system using these components exist: add redundancy or improve the reliability of the component. In reality, the most effective approach to almost any system will be some combination of these two approaches, in varying orders of magnitude for each component. Therefore, this research tries to answer the question of how to divide funds, between adding redundancy and improving the reliability of components, to most cost effectively improve the life cycle metrics of a system. While this question is relevant to any complex system, this research focuses on one type of system in particular: Separate Spacecraft Interferometers (SSI). Quantitative models are developed to analyze the key life cycle metrics of different SSI system architectures. Next, tools are developed to compare a given set of architectures in terms of total performance, by coupling different life cycle metrics together into one performance metric. Optimization tools, such as simulated annealing and genetic algorithms, are then used to search the entire design space to find the "optimal" architecture design. Sensitivity analysis tools have been developed to determine how sensitive the results of these analyses are to uncertain user defined parameters. Finally, several possibilities for the future work that could be done in this area of research are presented.
Supersonic variable-cycle engines
NASA Technical Reports Server (NTRS)
Willis, E. A.; Welliver, A. D.
1976-01-01
The evolution and current status of selected recent variable cycle engine (VCE) studies are reviewed, and how the results were influenced by airplane requirements is described. Promising VCE concepts are described, their designs are simplified and the potential benefits in terms of aircraft performance are identified. This includes range, noise, emissions, and the time and effort it may require to ensure technical readiness of sufficient depth to satisfy reasonable economic, performance, and environmental constraints. A brief overview of closely related, ongoing technology programs in acoustics and exhaust emissions is also presented. Realistic technology advancements in critical areas combined with well matched aircraft and selected VCE concepts can lead to significantly improved economic and environmental performance relative to first generation SST predictions.
Comparison of running and cycling economy in runners, cyclists, and triathletes.
Swinnen, Wannes; Kipp, Shalaya; Kram, Rodger
2018-07-01
Exercise economy is one of the main physiological factors determining performance in endurance sports. Running economy (RE) can be improved with running-specific training, while the improvement of cycling economy (CE) with cycling-specific training is controversial. We investigated whether exercise economy reflects sport-specific skills/adaptations or is determined by overall physiological factors. We compared RE and CE in 10 runners, 9 cyclists and 9 triathletes for running at 12 km/h and cycling at 200 W. Gross rates of oxygen consumption and carbon dioxide production were collected and used to calculate gross metabolic rate in watts for both running and cycling. Runners had better RE than cyclists (917 ± 107 W vs. 1111 ± 159 W) (p < 0.01). Triathletes had intermediate RE values (1004 ± 98 W) not different from runners or cyclists. CE was not different (p = 0.20) between the three groups (runners: 945 ± 60 W; cyclists: 982 ± 44 W; triathletes: 979 ± 54 W). RE can be enhanced with running-specific training, but CE is independent of cycling-specific training.
NASA Astrophysics Data System (ADS)
Kumar, Ravinder; Singh, Jagdev; Kundal, Pankaj
2018-05-01
Refrigeration, Ventilation and Air Conditioning system is the largest reason behind the increasing demand of energy consumption in the world and saving that energy through some innovative methods becomes a large issue for the researchers. Compressor is a primary component of the refrigeration cycle. The application of nanoparticles in refrigeration cycle overcomes the energy consumption issue by improving the compressor suction and discharge characteristics. In this paper, an experimental study is carried out to investigate the effect of copper oxide (CuO) nanoparticles on different parameters of the refrigeration cycle. CuO particles are appended with the system refrigerant through lubricating oil of the compressor. Further, the viscosity measurements and friction coefficient analysis of compressor lubricant for different fractions of nanoparticles has been investigated. The results showed that both the suction and discharge characteristics of the compressor were enhanced with the utilization of nanolubricant in LPG based refrigeration cycle. Nanoparticles additive in lubricant increases the viscosity which lead to a significant decrease in friction coefficient. The COP of the cycle was improved by 46%, as the energy consumption of the compressor was decreased by 7%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valenti, M.
This paper reports that as tougher emissions standards take hold throughout the industrialized world, manufacturers such as GE, Siemens, Foster Wheeler, and Asea Brown Boveri are designing advanced combined-cycle equipment that offers improved environmental performance without sacrificing power efficiency.
NASA Astrophysics Data System (ADS)
Wan, Wang; Wang, Chao; Zhang, Weidong; Chen, Jitao; Zhou, Henghui; Zhang, Xinxiang
2014-01-01
A nanoscale Fe3O4/porous carbon-multiwalled carbon nanotubes (MWCNTs) composite is synthesized through a simple hard-template method by using Fe2O3 nanoparticles as the precursor and SiO2 nanoparticles as the template. The composite shows good cycle performance (941 mAh g-1 for the first cycle at 0.1 C, with 106% capacity retention at the 80th cycle) and high rate capability (71% capacity retained at 5 C rate). Its excellent electrical properties can be attributed to the porous carbon framework structure, which is composed of carbon and MWCNTs. In this composite, the porous structure provides space for the change in Fe3O4 volume during cycling and shortens the lithium ion diffusion distance, the MWCNTs increase the electron conductivity, and the carbon coating reduces the risk of side reactions. The results provide clear evidences for the utility of porous carbon framework to improve the electrochemical performances of nanosized transition-metal oxides as anode materials for lithium-ion batteries.
NASA Astrophysics Data System (ADS)
Zhang, Xiaolong; Lin, Yu; Wu, Jihuai; Fang, Biaopeng; Zeng, Jiali
2018-04-01
In this paper, CuS film was deposited onto fluorine-doped tin oxide (FTO) substrate using a facile chemical bath deposition method, and then modified by PbS using simple successive ionic layer absorption and reaction (SILAR) method with different cycles. These CuS/PbS films were utilized as counter electrodes (CEs) for CdSe/CdS co-sensitized solar cells. Field-emission scanning electron microscopy equipped with an energy-dispersive X-ray spectrometer was used to characterize the CuS/PbS films. The results show that CuS/PbS (10 cycles) CE exhibits an improved power conversion efficiency of 5.54% under the illumination of one sun (100 mW cm-2), which is higher than the CuS/PbS (0 cycles), CuS/PbS (5 cycles), and CuS/PbS (15 cycles) CEs. This enhancement is mainly attributed to good catalytic activity and lower charge-transfer and series resistances, which have been proved by electrochemical impedance spectroscopy, and Tafel polarization measurements.
NASA Technical Reports Server (NTRS)
Turk, M. A.; Zeiner, P. K.
1986-01-01
In connection with the significant advances made regarding the performance of larger gas turbines, challenges arise concerning the improvement of small gas turbine engines in the 250 to 1000 horsepower range. In response to these challenges, the NASA/Army-sponsored Small Engine Component Technology (SECT) study was undertaken with the objective to identify the engine cycle, configuration, and component technology requirements for the substantial performance improvements desired in year-2000 small gas turbine engines. In the context of this objective, an American turbine engine company evaluated engines for four year-2000 applications, including a rotorcraft, a commuter aircraft, a supersonic cruise missile, and an auxiliary power unit (APU). Attention is given to reference missions, reference engines, reference aircraft, year-2000 technology projections, cycle studies, advanced engine selections, and a technology evaluation.
Mosaic-shaped cathode for highly durable solid oxide fuel cell under thermal stress
NASA Astrophysics Data System (ADS)
Joo, Jong Hoon; Jeong, Jaewon; Kim, Se Young; Yoo, Chung-Yul; Jung, Doh Won; Park, Hee Jung; Kwak, Chan; Yu, Ji Haeng
2014-02-01
In this study, we propose a novel "mosaic structure" for a SOFC (solid oxide fuel cell) cathode with high thermal expansion to improve the stability against thermal stress. Self-organizing mosaic-shaped cathode has been successfully achieved by controlling the amount of binder in the dip-coating solution. The anode-supported cell with mosaic-shaped cathode shows itself to be highly durable performance for rapid thermal cycles, however, the performance of the cell with a non-mosaic cathode exhibits severe deterioration originated from the delamination at the cathode/electrolyte interface after 7 thermal cycles. The thermal stability of an SOFC cathode can be evidently improved by controlling the surface morphology. In view of the importance of the thermal expansion properties of the cathode, the effects of cathode morphology on the thermal stress stability are discussed.
NASA Technical Reports Server (NTRS)
Darpel, Scott; Beckman, Sean
2016-01-01
Decades of systems engineering practice have demonstrated that the earlier the identification of requirements occurs, the lower the chance that costly redesigns will needed later in the project life cycle. A better understanding of all requirements can also improve the likelihood of a design's success. Significant effort has been put into developing tools and practices that facilitate requirements determination, including those that are part of the model-based systems engineering (MBSE) paradigm. These efforts have yielded improvements in requirements definition, but have thus far focused on a design's performance needs. The identification of safety & mission assurance (S&MA) related requirements, in comparison, can occur after preliminary designs are already established, yielding forced redesigns. Engaging S&MA expertise at an earlier stage, facilitated by the use of MBSE tools, and focused on actual project risk, can yield the same type of design life cycle improvements that have been realized in technical and performance requirements.
Gilkes, Lucy A; Liira, Helena; Emery, Jon
Medical students benefit from their contact with clinicians and patients in the clinical setting. However, little is known about whether patients and clinicians also benefit from medical students. We developed an audit and feedback intervention activity to be delivered by medical students to their general practice supervisors. We tested whether the repeated cycle of audit had an effect on the preventive care practices of general practitioners (GPs). The students performed an audit on topics of preventive medicine and gave feedback to their supervisors. Each supervisor in the study had more than one student performing the audit over the academic year. After repetitive cycles of audit and feedback, the recording of social history items by GPs improved. For example, recording alcohol history increased from 24% to 36%. This study shows that medical students can be effective auditors, and their repeated audits may improve their general practice supervisors' recording of some aspects of social history.
NASA Astrophysics Data System (ADS)
Wang, Xuekun; Li, Zhaoqiang; Zhang, Zhiwei; Li, Qun; Guo, Enyan; Wang, Chengxiang; Yin, Longwei
2015-02-01
We designed a facile infiltration route to synthesize mesoporous hollow structured Mo doped SnO2 using silica spheres as templates. It is observed that Mo is uniformly incorporated into SnO2 lattice in the form of Mo6+. The as-prepared mesoporous Mo-doped SnO2 LIBs anodes exhibit a significantly improved electrochemical performance with good cycling stability, high specific capacity and high rate capability. The mesoporous hollow Mo-doped SnO2 sample with 14 at% Mo doping content displays a specific capacity of 801 mA h g-1 after 60 cycles at a current density of 100 mA g-1, about 1.66 times higher than that of the pure SnO2 hollow sample. In addition, even if the current density is as high as 1600 mA g-1 after 60 cycles, it could still retain a stable specific capacity of 530 mA h g-1, exhibiting an extraordinary rate capability. The greatly improved electrochemical performance of the Mo-doped mesoporous hollow SnO2 sample could be attributed to the following factors. The large surface area and hollow structure can significantly enhance structural integrity by acting as mechanical buffer, effectively alleviating the volume changes generated during the lithiation/delithiation process. The incorporation of Mo into the lattice of SnO2 improves charge transfer kinetics and results in a faster Li+ diffusion rate during the charge-discharge process.
NASA Astrophysics Data System (ADS)
Wang, Peng; Hu, Junhua; Cao, Guoqin; Zhang, Shilin; Zhang, Peng; Liang, Changhao; Wang, Zhuo; Shao, Guosheng
2018-03-01
Different configurations of Sn and C films were deposited and used as a planar anode for Li ion battery. The interplay of carbon layer with Sn as supporting and buffering, respectively, was revealed. The suppression on the allotropic transformation to α phase by a carbon layer results in a significantly improved capacity retention rate, which also avoids the crack of Sn film. As expected, a conductive carbon layer improves rating performance. However, a supporting carbon layer (SC) just contributes to the charge transfer process. A DFT approach was used to assess the allotropic transformation process. An additional barrier (∼0.86 eV) exits on the α-β diagram, which is responsible for the irreversibility of α phase back to β phase. An enhanced persistence of β phase in Sn/C anode contributes to cycling performance. A Li rich condition contributes to the stabilization of β-Sn, which is thermodynamically favored. A nano buffering carbon (BC) layer can evidently alleviate the side reaction on Sn surface, which in turn promotes the diffusion of Li ions in electrode and generates a Li rich condition. The direct contact of Sn with electrolyte leads to serious accumulation of α-Sn during cycling and results in a poor cycling performance. By the synergistic effect of BC and SC, a sandwich C/Sn/C structure demonstrates an enchantment in electrochemical behavior.
Early change in thermal perception is not a driver of anticipatory exercise pacing in the heat.
Barwood, Martin James; Corbett, Jo; White, Danny; James, Jason
2012-10-01
Initial power output declines significantly during exercise in hot conditions on attaining a rapid increase in skin temperature when exercise commences. It is unclear whether this initial reduced power is mediated consciously, through thermal perceptual cues, or is a subconscious process. The authors tested the hypothesis that improved thermal perception (feeling cooler and more comfortable) in the absence of a change in thermal state (ie, similar deep-body and skin temperatures between spray conditions) would alter pacing and 40 km cycling time trial (TT) performance. Eleven trained participants (mean (SD): age 30 (8.1) years; height 1.78 (0.06) m; mass 76.0 (8.3) kg) completed three 40 km cycling TTs in standardised conditions (32°C, 50% RH) with thermal perception altered prior to exercise by application of cold-receptor-activating menthol spray (MENTHOL SPRAY), in contrast to a separate control spray (CONTROL SPRAY) and no spray control (CON). Thermal perception, perceived exertion, thermal responses and cycling TT performance were measured. MENTHOL SPRAY induced feelings of coolness and improved thermal comfort before and during exercise. Skin temperature profile at the start of exercise was similar between sprays (CON-SPRAY 33.3 (1.1)°C and MENTHOL SPRAY 33.4 (0.4)°C, but different to CON 34.5 (0.5)°C), but there was no difference in the pacing strategy adopted. There was no performance benefit using MENTHOL SPRAY; cycling TT completion time for CON is 71.58 (6.21) min, for CON-SPRAY is 70.94 (6.06) min and for MENTHOL SPRAY is 71.04 (5.47) min. The hypothesis is rejected. Thermal perception is not a primary driver of early pacing during 40 km cycling TT in hot conditions in trained participants.
Frémin, Christophe; Bessard, Anne; Ezan, Frédéric; Gailhouste, Luc; Régeard, Morgane; Le Seyec, Jacques; Gilot, David; Pagès, Gilles; Pouysségur, Jacques; Langouët, Sophie; Baffet, Georges
2009-03-01
We investigated the specific role of the mitogen-activated protein kinase (MAPK) extracellular signal-regulated kinase 1 (ERK1)/ERK2 pathway in the regulation of multiple cell cycles and long-term survival of normal hepatocytes. An early and sustained epidermal growth factor (EGF)-dependent MAPK activation greatly improved the potential of cell proliferation. In this condition, almost 100% of the hepatocytes proliferated, and targeting ERK1 or ERK2 via RNA interference revealed the specific involvement of ERK2 in this regulation. However, once their first cell cycle was performed, hepatocytes failed to undergo a second round of replication and stayed blocked in G1 phase. We demonstrated that sustained EGF-dependent activation of the MAPK/ERK kinase (MEK)/ERK pathway was involved in this blockage as specific transient inhibition of the cascade repotentiated hepatocytes to perform a new wave of replication and multiple cell cycles. We identified this mechanism by showing that this blockage was in part supported by ERK2-dependent p21 expression. Moreover, continuous MEK inhibition was associated with a lower apoptotic engagement, leading to an improvement of survival up to 3 weeks. Using RNA interference and ERK1 knockout mice, we extended these results by showing that this improved survival was due to the specific inhibition of ERK1 expression/phosphorylation and did not involve ERK2. Our results emphasize that transient MAPK inhibition allows multiple cell cycles in primary cultures of hepatocytes and that ERK2 has a key role in the regulation of S phase entry. Moreover, we revealed a major and distinct role of ERK1 in the regulation of hepatocyte survival. Taken together, our results represent an important advance in understanding long-term survival and cell cycle regulation of hepatocytes.
On the efficiency of FES cycling: a framework and systematic review.
Hunt, K J; Fang, J; Saengsuwan, J; Grob, M; Laubacher, M
2012-01-01
Research and development in the art of cycling using functional electrical stimulation (FES) of the paralysed leg muscles has been going on for around thirty years. A range of physiological benefits has been observed in clinical studies but an outstanding problem with FES-cycling is that efficiency and power output are very low. The present work had the following aims: (i) to provide a tutorial introduction to a novel framework and methods of estimation of metabolic efficiency using example data sets, and to propose benchmark measures for evaluating FES-cycling performance; (ii) to systematically review the literature pertaining specifically to the metabolic efficiency of FES-cycling, to analyse the observations and possible explanations for the low efficiency, and to pose hypotheses for future studies which aim to improve performance. We recommend the following as benchmark measures for assessment of the performance of FES-cycling: (i) total work efficiency, delta efficiency and stimulation cost; (ii) we recommend, further, that these benchmark measures be complemented by mechanical measures of maximum power output, sustainable steady-state power output and endurance. Performance assessments should be carried out at a well-defined operating point, i.e. under conditions of well controlled work rate and cadence, because these variables have a strong effect on energy expenditure. Future work should focus on the two main factors which affect FES-cycling performance, namely: (i) unfavourable biomechanics, i.e. crude recruitment of muscle groups, non-optimal timing of muscle activation, and lack of synergistic and antagonistic joint control; (ii) non-physiological recruitment of muscle fibres, i.e. mixed recruitment of fibres of different type and deterministic constant-frequency stimulation. We hypothesise that the following areas may bring better FES-cycling performance: (i) study of alternative stimulation strategies for muscle activation including irregular stimulation patterns (e.g. doublets, triplets, stochastic patterns) and variable frequency stimulation trains, where it appears that increasing frequency over time may be profitable; (ii) study of better timing parameters for the stimulated muscle groups, and addition of more muscle groups: this path may be approached using EMG studies and constrained numerical optimisation employing dynamic models; (iii) development of optimal stimulation protocols for muscle reconditioning and FES-cycle training.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, Benjamin S.; Hamilton, Steven P.; Jarrett, Michael G.
This report describes the performance improvements made to the VERA Core Simulator (VERA-CS) during FY2016. The development of the VERA Core Simulator has focused on the capability needed to deplete physical reactors and help solve various problems; this capability required the accurate simulation of many operating cycles of a nuclear power plant. The first section of this report introduces two test problems used to assess the run-time performance of VERA-CS using a source dated February 2016. The next section provides a brief overview of the major modifications made to decrease the computational cost. Following the descriptions of the major improvements,more » the run-time for each improvement is shown. Conclusions on the work are presented, and further follow-on performance improvements are suggested.« less
Stirling Air Conditioner for Compact Cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-09-01
BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry tomore » make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.« less
Radiology operations: what you don't know could be costing you millions.
Joffe, Sam; Drew, Donna; Bansal, Manju; Hase, Michael
2007-01-01
Rapid growth in advanced imaging procedures has left hospital radiology departments struggling to keep up with demand, resulting in loss of patients to facilities that can offer service more quickly. While the departments appear to be working at full capacity, an operational analysis of over 400 hospital radiology departments in the US by GE Healthcare has determined that, paradoxically, many departments are in fact underutilized and operating for below their potential capacity. While CT cycle time in hospitals that were studied averaged 35 minutes, top performing hospitals operated the same equipment at a cycle time of 15 minutes, yielding approximately double the throughput volume. Factors leading to suboptimal performance include accounting metrics that mask true performance, leadership focus on capital investment rather than operations, under staffing, under scheduling, poorly aligned incentives, a fragmented view of operations, lack of awareness of latent opportunities, and lack of sufficient skills and processes to implement improvements. The study showed how modest investments in radiology operations can dramatically improve access to services and profitability.
Arena, Umberto; Ardolino, Filomena; Di Gregorio, Fabrizio
2015-07-01
An attributional life cycle analysis (LCA) was developed to compare the environmental performances of two waste-to-energy (WtE) units, which utilize the predominant technologies among those available for combustion and gasification processes: a moving grate combustor and a vertical shaft gasifier coupled with direct melting. The two units were assumed to be fed with the same unsorted residual municipal waste, having a composition estimated as a European average. Data from several plants in operation were processed by means of mass and energy balances, and on the basis of the flows and stocks of materials and elements inside and throughout the two units, as provided by a specific substance flow analysis. The potential life cycle environmental impacts related to the operations of the two WtE units were estimated by means of the Impact 2002+ methodology. They indicate that both the technologies have sustainable environmental performances, but those of the moving grate combustion unit are better for most of the selected impact categories. The analysis of the contributions from all the stages of each specific technology suggests where improvements in technological solutions and management criteria should be focused to obtain further and remarkable environmental improvements. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reliability improvements in tunable Pb1-xSnxSe diode lasers
NASA Technical Reports Server (NTRS)
Linden, K. J.; Butler, J. F.; Nill, K. W.; Reeder, R. E.
1980-01-01
Recent developments in the technology of Pb-salt diode lasers which have led to significant improvements in reliability and lifetime, and to improved operation at very long wavelengths are described. A combination of packaging and contacting-metallurgy improvements has led to diode lasers that are stable both in terms of temperature cycling and shelf-storage time. Lasers cycled over 500 times between 77 K and 300 K have exhibited no measurable changes in either electrical contact resistance or threshold current. Utilizing metallurgical contacting process, both lasers and experimental n-type and p-type bulk materials are shown to have electrical contact resistance values that are stable for shelf storage periods well in excess of one year. Problems and experiments which have led to devices with improved performance stability are discussed. Stable device configurations achieved for material compositions yielding lasers which operate continuously at wavelengths as long as 30.3 micrometers are described.
NASA Astrophysics Data System (ADS)
Wang, Long; Ma, Yulin; Li, Qin; Zhou, Zhenxin; Cheng, Xinqun; Zuo, Pengjian; Du, Chunyu; Gao, Yunzhi; Yin, Geping
2017-09-01
1,3,6-Hexanetricarbonitrile (HTN) has been investigated as an electrolyte additive to improve the electrochemical performance of the Li1.2Ni0.13Co0.13Mn0.54O2 cathode at high operating voltage (4.8 V). Linear sweep voltammetry (LSV) results indicate that HTN can improve the oxidation potential of the electrolyte. The influences of HTN on the electrochemical behaviors and surface properties of the cathode at high voltage have been investigated by galvanostatic charge/discharge test, electrochemical impedance spectroscopy (EIS), and ex-situ physical characterizations. Charge-discharge results demonstrate that the capacity retention of the Li1.2Ni0.13Co0.13Mn0.54O2 cathode in 1% HTN-containing electrolyte after 150 cycles at 0.5 C is improved to 92.3%, which is much higher than that in the standard electrolyte (ED). Combined with the theoretical calculation, ICP tests, XRD and XPS analysis, more stable and homogeneous interface film is confirmed to form on the cathode surface with incorporation of HTN, meanwhile, the electrolyte decomposition and the cathode structural destruction are restrained effectively upon cycling at high voltage, leading to improved electrochemical performance of Li1.2Ni0.13Co0.13Mn0.54O2 cathode.
Highly improved voltage efficiency of seawater battery by use of chloride ion capturing electrode
NASA Astrophysics Data System (ADS)
Kim, Kyoungho; Hwang, Soo Min; Park, Jeong-Sun; Han, Jinhyup; Kim, Junsoo; Kim, Youngsik
2016-05-01
Cost-effective and eco-friendly battery system with high energy density is highly desirable. Herein, we report a seawater battery with a high voltage efficiency, in which a chloride ion-capturing electrode (CICE) consisting of Ag foil is utilized as the cathode. The use of Ag as the cathode leads to a sharp decrease in the voltage gaps between charge and discharge curves, based on reversible redox reaction of Ag/AgCl (at ∼2.9 V vs. Na+/Na) in a seawater catholyte during cycling. The Ag/AgCl reaction proves to be highly reversible during battery cycling. The battery employing the Ag electrode shows excellent cycling performance with a high Coulombic efficiency (98.6-98.7%) and a highly improved voltage efficiency (90.3% compared to 73% for carbonaceous cathode) during 20 cycles (total 500 h). These findings demonstrate that seawater batteries using a CICE could be used as next-generation batteries for large-scale stationary energy storage plants.
Compliance with the guide for commissioning oral surgery: an audit and discussion.
Modgill, O; Shah, A
2017-10-13
Introduction The Guide for commissioning oral surgery and oral medicine published by NHS England (2015) prescribes the level of complexity of oral surgery and oral medicine investigations and procedures to be carried out within NHS services. These are categorised as Level 1, Level 2, Level 3A and Level 3B. An audit was designed to ascertain the level of oral surgery procedures performed by clinicians of varying experience and qualification working in a large oral surgery department within a major teaching hospital.Materials and methods Two audit cycles were conducted on retrospective case notes and radiographic review of 100 patient records undergoing dental extractions within the Department of Oral Surgery at King's College Dental Hospital. The set gold standard was: '100% of Level 1 procedures should be performed by dental undergraduates or discharged back to the referring general dental practitioner'. Data were collected and analysed on a Microsoft Excel spreadsheet. The results of the first audit cycle were presented to all clinicians within the department in a formal meeting, recommendations were made and an action plan implemented prior to undertaking a second cycle.Results The first cycle revealed that 25% of Level 1 procedures met the set gold standard, with Level 2 practitioners performing the majority of Level 1 and Level 2 procedures. The second cycle showed a marked improvement, with 66% of Level 1 procedures meeting the set gold standard.Conclusion Our audit demonstrates that whilst we were able to achieve an improvement with the set gold standard, several barriers still remain to ensure that patients are treated by the appropriate level of clinician in a secondary care setting. We have used this audit as a foundation upon which to discuss the challenges faced in implementation of the commissioning framework within both primary and secondary dental care and strategies to overcome these challenges, which are likely to be encountered in any NHS care setting in which oral surgery procedures are performed.
Crushed Ice Ingestion Does Not Improve Female Cycling Time Trial Performance in the Heat.
Zimmermann, Matthew; Landers, Grant Justin; Wallman, Karen Elizabeth
2017-02-01
This study examined the effects of precooling via ice ingestion on female cycling performance in hot, humid conditions. Ten female endurance athletes, mean age (28 ± 6 y), height (167.6 ± 6.5 cm) and body-mass (68.0 ± 11.5 kg) participated in the study. Participants completed an 800 kJ cycle time-trial in hot, humid conditions (34.9 ± 0.3 °C, 49.8 ± 3.5% RH). This was preceded by the consumption of 7 g∙kg -1 of crushed ice (ICE) or water (CON). There was no difference in performance time (CON 3851 ± 449 s; ICE 3767 ± 465 s), oxygen consumption (CON 41.6 ± 7.0 ml∙kg∙min -1 ; ICE 42.4 ± 6.0 ml∙kg∙min -1 ) or respiratory exchange ratio (CON 0.88 ± 0.05; ICE 0.90 ± 0.06) between conditions (p > .05, d < 0.5). Core and skin temperature following the precooling period were lower in ICE (T c 36.4 ± 0.4 °C; T sk 31.6 ± 1.2 °C) compared with CON (T c 37.1 ± 0.4 °C; T sk 32.4 ± 0.7 °C) and remained lower until the 100 kJ mark of the cycle time-trial (p < .05, d > 1.0). Sweat onset occurred earlier in CON (228 ± 113 s) compared with ICE (411 ± 156 s) (p < .05, d = 1.63). Mean thermal sensation (CON 1.8 ± 2.0; ICE 1.2 ± 2.5, p < .05, d = 2.51), perceived exertion (CON 15.3 ± 2.9; ICE 14.9 ± 3.0, p < .05, d = 0.38) and perceived thirst (CON 5.6 ± 2.2; ICE 4.6 ± 2.4, p < .05, d = 0.98) were lower in ICE compared with CON. Crushed ice ingestion did not improve cycling performance in females, although perceptual responses were reduced.
Development of a 10 Ah, Prismatic, Lithium-Ion Cell for NASA/GSFC
NASA Technical Reports Server (NTRS)
Stein, Brian; Baker, John W.; George, Douglas S.; Isaacs, Nathan D.; Shah, Pinakin M.; Rao, Gopalakrishna M.; Day, John H. (Technical Monitor)
2001-01-01
MSA's 10 Ah Li-ion cell is a rugged design suitable for the stringent requirements of aerospace applications. Eighteen cells demonstrate consistent cycling performance over a wide range of rates and temperatures. The cell passes qualification requirements for vibration survivability technology improvements at MSA continue to enhance cell performance.
Han, Yuzhen; Yu, Danni; Zhou, Junwen; Xu, Peiyu; Qi, Pengfei; Wang, Qianyou; Li, Siwu; Fu, Xiaotao; Gao, Xing; Jiang, Chenghao; Feng, Xiao; Wang, Bo
2017-08-25
A thin layer of a highly porous metal-organic framework material, ZIF-8, is fabricated uniformly on the surface of nanostructured transition metal oxides (ZnO nanoflakes and MnO 2 nanorods) to boost the transfer of lithium ions. The novel design and uniform microstructure of the MOF-coated TMOs (ZIF-8@TMOs) exhibit dramatically enhanced rate and cycling performance comparing to their pristine counterparts. The capacities of ZIF-8@ZnO (nanoflakes) and ZIF-8@MnO 2 (nanorods) are 28 % and 31 % higher that of the pristine ones at the same current density. The nanorods of ZIF-8@MnO 2 show a capacity of 1067 mAh g -1 after 500 cycles at 1 Ag -1 and without any fading. To further improve the conductivity and capacity, the ZIF-8-coated materials are pyrolyzed at 700 °C in an N 2 atmosphere (ZIF-8@TMO-700 N). After pyrolysis, a much higher capacity improvement is achieved: ZIF-8@ZnO-700 N and ZIF-8@MnO 2 -700 N have 54 % and 69 % capacity increases compared with the pristine TMOs, and at 1 Ag -1 , the capacity of ZIF-8@MnO 2 -700 N is 1060 mAh g -1 after cycling for 300 cycles. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Double polymer sheathed carbon nanotube supercapacitors show enhanced cycling stability
NASA Astrophysics Data System (ADS)
Zhao, Wenqi; Wang, Shanshan; Wang, Chunhui; Wu, Shiting; Xu, Wenjing; Zou, Mingchu; Ouyang, An; Cao, Anyuan; Li, Yibin
2015-12-01
Pseudo-materials are effective in boosting the specific capacitance of supercapacitors, but during service their degradation may also be very strong, causing reduced cycling stability. Here, we show that a carbon nanotube sponge grafted by two conventional pseudo-polymer layers in sequence can serve as a porous supercapacitor electrode with significantly enhanced cycling stability compared with single polymer grafting. Creating conformal polymer coatings on the nanotube surface and the resulting double-sheath configuration are important structural factors leading to the enhanced performance. Combining different polymers as double sheaths as reported here might be a potential route to circumvent the dilemma of pseudo-materials, and to simultaneously improve the capacitance and stability for various energy storage devices.Pseudo-materials are effective in boosting the specific capacitance of supercapacitors, but during service their degradation may also be very strong, causing reduced cycling stability. Here, we show that a carbon nanotube sponge grafted by two conventional pseudo-polymer layers in sequence can serve as a porous supercapacitor electrode with significantly enhanced cycling stability compared with single polymer grafting. Creating conformal polymer coatings on the nanotube surface and the resulting double-sheath configuration are important structural factors leading to the enhanced performance. Combining different polymers as double sheaths as reported here might be a potential route to circumvent the dilemma of pseudo-materials, and to simultaneously improve the capacitance and stability for various energy storage devices. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05978j
Effects of different warm-up modalities on power output during the high pull.
Barnes, Matthew John; Petterson, Ashley; Cochrane, Darryl J
2017-05-01
This study compared the effects of six warm-up modalities on peak power output (PPO) during the high-pull exercise. Nine resistance-trained males completed six trials using different warm-ups: high-pull specific (HPS), cycle, whole body vibration (WBV), cycle+HPS, WBV+HPS and a control. Intramuscular temperature (T m ) was increased by 2°C using WBV or cycling. PPO, T m and electromyography (EMG) were recorded during each trial. Two high-pulls were performed prior to and 3 min after participants completed the warm-up. The greatest increase in PPO occurred with HPS (232.8 ± 89.7 W, P < 0.001); however, this was not different to combined warm-ups (cycle+HPS 158.6 ± 121.1 W; WBV+HPS 177.3 ± 93.3 W, P = 1.00). These modalities increased PPO to a greater extent than those that did not involve HPS (all P < 0.05). HPS took the shortest time to complete, compared to the other conditions (P < 0.05). EMG did not differ from pre to post warm-up or between modalities in any of the muscles investigated. No change in T m occurred in warm-ups that did not include cycling or WBV. These results suggest that a movement-specific warm-up improves performance more than temperature-related warm-ups. Therefore, mechanisms other than increased muscle temperature and activation may be important for improving short-term PPO.
NASA Astrophysics Data System (ADS)
Zhao, Weimin; Zheng, Guorui; Lin, Min; Zhao, Wengao; Li, Dongjiang; Guan, Xiaoyun; Ji, Yajuan; Ortiz, Gregorio F.; Yang, Yong
2018-03-01
Although the LiNi0.5Mn0.25Co0.25O2 holds the merits of high theoretical capacities and a relatively high operating voltage, the battery performance suffers from the severe cycling decay due to the unstable solid electrolyte interface on the cathode. Herein, we present LiPO2F2 as a salt-type electrolyte additive to enhance the cycling stability of large-size crystallite LiNi0.5Mn0.25Co0.25O2 cathodes. Results demonstrate that 1 wt% LiPO2F2 can significantly improve not only the initial coulombic efficiency by 3%, but also the cycling stability and rate capability at 25 °C. Furthermore, the discharge capacity of LiNi0.5Mn0.25Co0.25O2 cathodes still maintain 156 mAh g-1 after 100 cycles even when the temperature increases to 55 °C. In-depth experimental characterization and theoretical calculation indicate that a new stable and thin (e.g. 15-20 nm) film formed on the surface of the cathodes, with composition of LiPO2F2, LiF, etc., which significantly reduces charge transfer impedance of the electrodes, and therefore significantly improves the cycling and rate performance of LiNi0.5Mn0.25Co0.25O2.
Study on the Effect of Straw Fiber on the Performance of Volcanic Slag Concrete
NASA Astrophysics Data System (ADS)
Xiao, Li-guang; Liu, Xi-xu
2018-03-01
In this paper, the effects of straw fiber on the working performance, mechanical properties and frost resistance of volcanic slag lightweight aggregate concrete were studied. The experimental results show that the straw fiber is subjected to surface carbonization treatment and mixed into the volcanic slag light aggregate concrete. The flexural strength and fracture pressure ratio of volcanic slag lightweight aggregate concrete are improved obviously Improved volcanic slag lightweight aggregate concrete brittleness improves toughness. Carbonized straw fiber greatly improves the frost resistance of volcanic slag lightweight aggregate concrete. So that the volcanic slag light aggregate concrete freeze-thaw cycle can reach 300 times.
Kritas, S K; Marubashi, T; Filioussis, G; Petridou, E; Christodoulopoulos, G; Burriel, A R; Tzivara, A; Theodoridis, A; Pískoriková, M
2015-01-01
This field study assessed the efficacy of a probiotic based on viable spores of Bacillus subtilis C-3102 (Calsporin; Calpis Co. Ltd., Japan) on the health status and productivity of sows and their litters through 2 full, sequential reproductive cycles from service of the first cycle to weaning of the second cycle. Fifty-six sows were allocated to 2 experimental groups, an untreated control (T1) group and a probiotic-treated (T2) group that received the same basal feed as the T1 group plus the probiotic at an approximate allowance of 30 g/t of feed (3 × 10(5) cfu/g). The offspring of T1 and T2 sows were offered basal and T2 creep feed (3 × 10(5) cfu/g), respectively. Health and zootechnical parameters of sows and piglets were recorded. Feeding the probiotic to sows and piglets resulted in significant benefits, observed in both cycles: 1) improved sow body condition during pregnancy (P < 0.05), 2) increased sow feed consumption, 3) reduced sow weight loss during lactation (P < 0.05), 4) reduced sow weaning-estrus interval (P < 0.05), and 5) higher BW of piglets at weaning (P < 0.05). Additionally, a significant (P < 0.05) improvement in piglet birth weight and in the number of piglets weaned was observed in the second cycle of T2 sows, while a significant improvement of mean daily gain of piglets from birth to weaning was observed in the first cycle of T2 sows. Microbiological examination of fecal samples showed that probiotic treatment significantly reduced both Escherichia coli and Clostridium spp. in piglet feces, particularly during the second cycle. The data suggested that continuous feed supplementation with the probiotic is beneficial for both sows and piglets, since zootechnical benefits were observed in both cycles.
High-performance concrete : applying life-cycle cost analysis and developing specifications.
DOT National Transportation Integrated Search
2016-12-01
Numerous studies and transportation agency experience across the nation have established that highperformance concrete (HPC) technology improves concrete quality and extends the service life of concrete structures at risk of chlorideinduced cor...
CNTs in situ attached to α-Fe2O3 submicron spheres for enhancing lithium storage capacity.
Gao, Guo; Zhang, Qiang; Cheng, Xin-Bing; Qiu, Peiyu; Sun, Rongjin; Yin, Ting; Cui, Daxiang
2015-01-14
In this work, we developed a facile hydrothermal method for synthesis of hybrid α-Fe2O3-carbon nanotubes (CNTs) architectures (α-Fe2O3-CNTs-1 and α-Fe2O3-CNTs-2). The CNTs are in situ attached to the α-Fe2O3 submicron spheres and form three-dimensional network robust architectures. The increase in the amount of CNTs in the network α-Fe2O3-CNTs architectures will significantly enhance the cycling and rate performance, as the flexible and robust CNTs could ensure the fast electron transport pathways, enhance the electronic conductivity, and improve the structural stability of the electrode. As for pure α-Fe2O3 submicron spheres, the capacity decreased significantly and retained at 377.4 mAh g(-1) after 11 cycles, and the capacity has a slightly increasing trend at the following cycling. In contrast, the network α-Fe2O3-CNTs-2 electrode shows the most remarkable performance. At the 60th cycle, the capacity of network α-Fe2O3-CNTs-2 (764.5 mAh g(-1)) is 1.78 times than that of α-Fe2O3 submicron spheres (428.3 mAh g(-1)). The long-term cycling performance (1000 cycles) of samples at a high current density of 5 C showed that the capacity of α-Fe2O3 submicron spheres fade to ∼37.3 mAh g(-1) at the 400th cycle and gradually increased to ∼116.7 mAh g(-1) at the 1000th cycle. The capacity of network α-Fe2O3-CNTs-2 maintained at ∼220.2 mAh g(-1) before the 400th cycle, arrived at ∼326.5 mAh g(-1) in the 615th, cycle and retained this value until 1000th cycle. The network α-Fe2O3-CNTs-2 composite could significantly enhance the cycling and rate performance than pure α-Fe2O3 submicron spheres composite.
Rigamonti, L; Falbo, A; Grosso, M
2013-11-01
This paper reports some of the findings of the 'GERLA' project: GEstione Rifiuti in Lombardia - Analisi del ciclo di vita (Waste management in Lombardia - Life cycle assessment). The project was devoted to support Lombardia Region in the drafting of the new waste management plan by applying a life cycle thinking perspective. The present paper mainly focuses on four Provinces in the Region, which were selected based on their peculiarities. Life cycle assessment (LCA) was adopted as the methodology to assess the current performance of the integrated waste management systems, to discuss strengths and weaknesses of each of them and to design their perspective evolution as of year 2020. Results show that despite a usual business approach that is beneficial to all the provinces, the introduction of technological and management improvements to the system provides in general additional energy and environmental benefits for all four provinces. The same improvements can be easily extended to the whole Region, leading to increased environmental benefits from the waste management sector, in line with the targets set by the European Union for 2020. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Amos, D. J.
1977-01-01
An analytical evaluation was conducted to determine quantitatively the improvement potential in cycle efficiency and cost of electricity made possible by the introduction of thermal barrier coatings to power generation combustion turbine systems. The thermal barrier system, a metallic bond coat and yttria stabilized zirconia outer layer applied by plasma spray techniques, acts as a heat insulator to provide substantial metal temperature reductions below that of the exposed thermal barrier surface. The study results show the thermal barrier to be a potentially attractive means for improving performance and reducing cost of electricity for the simple, recuperated, and combined cycles evaluated.
A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.
Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing
2016-12-01
To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients' breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors' preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management.
The Use of an Ultra-Compact Combustor as an Inter-Turbine Burner for Improved Engine Performance
2014-03-27
27 25 NPSS Mixed Flow Turbofan Model - Element and Link Names . . . . . . . . . 30 26 VCE with Variable Components Labeled...the power generation, Vogeler proposed the Sequential Combustion Cycle (SCC) for use in aircraft engines [13]. For a conventional turbofan with a...single combustor, thrust is a function of bypass ratio and maximum pressure and temperature in the cycle. Considering a twin spool turbofan engine as
NASA Astrophysics Data System (ADS)
Peng, Zhenhuan; Fang, Wenying; Zhao, Hongbin; Fang, Jianhui; Cheng, Hongwei; Doan, The Nam Long; Xu, Jiaqiang; Chen, Pu
2015-05-01
Ultrathin microporous carbon (UMPC) for lithium-sulfur (Li-S) cathode with uniform pore width of approximately 0.6 nm and dozens nm in thickness is synthesized with graphene oxide as template by glucose hydrothermal carbonization and surfactant-assisted assembling method. The UMPC supplies desirable S pregnancy space and the intimate contact between UMPC and S, therefore improving the conductivity of S@UMPC composite and dynamic performance. Smaller sulfur molecules limited in UMPC thoroughly prevent the formation of electrolyte-soluble polysulfides, hence excellent cycling performance with 900 mAh g-1 after 150 cycles is kept. Ultrathin three-dimensional carbon nanosheets are significant to fast electron transfer and Li+ diffusion contributing to excellent dynamic performance (710 mAh g-1 at 3 C).
Band edge engineering of TiO2@DNA nanohybrids and implications for capacitive energy storage devices
NASA Astrophysics Data System (ADS)
Imani, Roghayeh; Pazoki, Meysam; Tiwari, Ashutosh; Boschloo, G.; Turner, Anthony P. F.; Kralj-Iglič, V.; Iglič, Aleš
2015-06-01
Novel mesoporous TiO2@DNA nanohybrid electrodes, combining covalently encoded DNA with mesoporous TiO2 microbeads using dopamine as a linker, were prepared and characterised for application in supercapacitors. Detailed information about donor density, charge transfer resistance and chemical capacitance, which have an important role in the performance of an electrochemical device, were studied by electrochemical methods. The results indicated the improvement of electrochemical performance of the TiO2 nanohybrid electrode by DNA surface functionalisation. A supercapacitor was constructed from TiO2@DNA nanohybrids with PBS as the electrolyte. From the supercapacitor experiment, it was found that the addition of DNA played an important role in improving the specific capacitance (Cs) of the TiO2 supercapacitor. The highest Cs value of 8 F g-1 was observed for TiO2@DNA nanohybrids. The nanohybrid electrodes were shown to be stable over long-term cycling, retaining 95% of their initial specific capacitance after 1500 cycles.Novel mesoporous TiO2@DNA nanohybrid electrodes, combining covalently encoded DNA with mesoporous TiO2 microbeads using dopamine as a linker, were prepared and characterised for application in supercapacitors. Detailed information about donor density, charge transfer resistance and chemical capacitance, which have an important role in the performance of an electrochemical device, were studied by electrochemical methods. The results indicated the improvement of electrochemical performance of the TiO2 nanohybrid electrode by DNA surface functionalisation. A supercapacitor was constructed from TiO2@DNA nanohybrids with PBS as the electrolyte. From the supercapacitor experiment, it was found that the addition of DNA played an important role in improving the specific capacitance (Cs) of the TiO2 supercapacitor. The highest Cs value of 8 F g-1 was observed for TiO2@DNA nanohybrids. The nanohybrid electrodes were shown to be stable over long-term cycling, retaining 95% of their initial specific capacitance after 1500 cycles. Electronic supplementary information (ESI) available: The HRTEM analysis of TiO2 microbeads, XPS spectra of modified electrodes (Ti 2p and O 1s peaks), total number of surface states vs applied potential (calculated DOS) of modified electrodes, circuit used for EIS data fitting, specific capacitance of FTO/TiO2/DA/DNA calculated from Galvanostatic charge-discharge test versus cycle number. See DOI: 10.1039/c5nr02533h
Tungsten fiber reinforced superalloys: A status review
NASA Technical Reports Server (NTRS)
Petrasek, D. W.; Signorelli, R. A.
1981-01-01
Improved performance of heat engines is largely dependent upon maximum cycle temperatures. Tungsten fiber reinforced superalloys (TFRS) are the first of a family of high temperature composites that offer the potential for significantly raising hot component operating temperatures and thus leading to improved heat engine performance. This status review of TFRS research emphasizes the promising property data developed to date, the status of TFRS composite airfoil fabrication technology, and the areas requiring more attention to assure their applicability to hot section components of aircraft gas turbine engines.
NASA Technical Reports Server (NTRS)
Petrasek, Donald W.; Signorelli, Robert A.; Caulfield, Thomas; Tien, John K.
1987-01-01
Improved performance of heat engines is largely dependent upon maximum cycle temperatures. Tungsten fiber reinforced superalloys (TFRS) are the first of a family of high temperature composites that offer the potential for significantly raising hot component operating temperatures and thus leading to improved heat engine performance. This status review of TFRS research emphasizes the promising property data developed to date, the status of TFRS composite airfoil fabrication technology, and the areas requiring more attention to assure their applicability to hot section components of aircraft gas turbine engines.
Chen, Ailian; Li, Caixia; Tang, Rui; Yin, Longwei; Qi, Yongxin
2013-08-28
A novel hybrid of MoO2-ordered mesoporous carbon (MoO2-OMC) was prepared through a two-step solvothermal chemical reaction route. The electrochemical performances of the mesoporous MoO2-OMC hybrids were examined using galvanostatical charge-discharge, cyclic voltammetry, and electrochemical impedance spectroscopy (EIS) techniques. The MoO2-OMC hybrid exhibits significantly improved electrochemical performance of high reversible capacity, high-rate capability, and excellent cycling performance as an anode electrode material for Li ion batteries. It is revealed that the MoO2-OMC hybrid could deliver the first discharge capacity of 1641.8 mA h g(-1) with an initial Coulombic efficiency of 63.6%, and a reversible capacity as high as 1049.1 mA h g(-1) even after 50 cycles at a current density of 100 mA g(-1), much higher than the theoretical capacity of MoO2 (838 mA h g(-1)) and OMC materials. The MoO2-OMC hybrid demonstrates an excellent high rate capability with capacity of ∼600 mA h g(-1) even at a charge current density of 1600 mA g(-1) after 50 cycles, which is approximately 11.1 times higher than that of the OMC (54 mA h g(-1)) materials. The improved rate capability and reversible capacity of the MoO2-OMC hybrid are attributed to a synergistic reaction between the MoO2 nanoparticles and mesoporous OMC matrices. It is noted that the electrochemical performance of the MoO2-OMC hybrid is evidently much better than the previous MoO2-based hybrids.
Cordery, P; Peirce, N; Maughan, R J; Watson, P
2017-11-01
Catecholamine reuptake inhibition improves the performance of male volunteers exercising in warm conditions, but sex differences in thermoregulation, circulating hormones, and central neurotransmission may alter this response. With local ethics committee approval, nine physically active women (mean ± SD age 21 ± 2 years; height 1.68 ± 0.08 m; body mass 64.1 ± 6.0 kg; VO 2peak 51 ± 7 mL/kg/min) were recruited to examine the effect of pre-exercise administration of Bupropion (BUP; 4 × 150 mg) on prolonged exercise performance in a warm environment. Participants completed a VO 2peak test, two familiarization trials, and two randomized, double-blind experimental trials. All trials took place during the first 10 days of the follicular phase of the menstrual cycle. Participants cycled for 1 h at 60% VO 2peak followed by a 30-min performance test. Total work done was greater during the BUP trial (291 ± 48 kJ) than the placebo trial (269 ± 46 kJ, P = 0.042, d = 0.497). At the end of the performance test, core temperature was higher on the BUP trial (39.5 ± 0.4 °C) than on the placebo trial (39.2 ± 0.6 °C, P = 0.021; d = 0.588), as was heart rate (185 ± 9 vs 179 ± 13, P = 0.043; d = 0.537). The results indicate that during the follicular phase of the menstrual cycle, an acute dosing protocol of BUP can improve self-regulated performance in warm conditions. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Performance Assessment as a Diagnostic Tool for Science Teachers
NASA Astrophysics Data System (ADS)
Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap
2018-04-01
Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, Chris, E-mail: cyuan@uwm.edu; Wang, Endong; Zhai, Qiang
Temporal homogeneity of inventory data is one of the major problems in life cycle assessment (LCA). Addressing temporal homogeneity of life cycle inventory data is important in reducing the uncertainties and improving the reliability of LCA results. This paper attempts to present a critical review and discussion on the fundamental issues of temporal homogeneity in conventional LCA and propose a theoretical framework for temporal discounting in LCA. Theoretical perspectives for temporal discounting in life cycle inventory analysis are discussed first based on the key elements of a scientific mechanism for temporal discounting. Then generic procedures for performing temporal discounting inmore » LCA is derived and proposed based on the nature of the LCA method and the identified key elements of a scientific temporal discounting method. A five-step framework is proposed and reported in details based on the technical methods and procedures needed to perform a temporal discounting in life cycle inventory analysis. Challenges and possible solutions are also identified and discussed for the technical procedure and scientific accomplishment of each step within the framework. - Highlights: • A critical review for temporal homogeneity problem of life cycle inventory data • A theoretical framework for performing temporal discounting on inventory data • Methods provided to accomplish each step of the temporal discounting framework.« less
Alkatan, Mohammed; Baker, Jeffrey R; Machin, Daniel R; Park, Wonil; Akkari, Amanda S; Pasha, Evan P; Tanaka, Hirofumi
2016-03-01
Arthritis and its associated joint pain act as significant barriers for adults attempting to perform land-based physical activity. Swimming can be an ideal form of exercise for patients with arthritis. Yet there is no information on the efficacy of regular swimming exercise involving patients with arthritis. The effect of a swimming exercise intervention on joint pain, stiffness, and physical function was evaluated in patients with osteoarthritis (OA). Using a randomized study design, 48 sedentary middle-aged and older adults with OA underwent 3 months of either swimming or cycling exercise training. Supervised exercise training was performed for 45 min/day, 3 days/week at 60-70% heart rate reserve for 12 weeks. The Western Ontario and McMaster Universities Arthritis Index was used to measure joint pain, stiffness, and physical limitation. After the exercise interventions, there were significant reductions in joint pain, stiffness, and physical limitation accompanied by increases in quality of life in both groups (all p < 0.05). Functional capacity as assessed by maximal handgrip strength, isokinetic knee extension and flexion power (15-30% increases), and the distance covered in the 6-min walk test increased (all p < 0.05) in both exercise groups. No differences were observed in the magnitude of improvements between swimming and cycling training. Regular swimming exercise reduced joint pain and stiffness associated with OA and improved muscle strength and functional capacity in middle-aged and older adults with OA. Additionally, the benefits of swimming exercise were similar to the more frequently prescribed land-based cycling training. clinicaltrials.gov NCT01836380.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rigamonti, L., E-mail: lucia.rigamonti@polimi.it; Falbo, A.; Grosso, M.
Highlights: • LCA was used for evaluating the performance of four provincial waste management systems. • Milano, Bergamo, Pavia and Mantova (Italy) are the provinces selected for the analysis. • Most of the data used to model the systems are primary. • Significant differences were found among the provinces located in the same Region. • LCA was used as a decision-supporting tool by Regione Lombardia. - Abstract: This paper reports some of the findings of the ‘GERLA’ project: GEstione Rifiuti in Lombardia – Analisi del ciclo di vita (Waste management in Lombardia – Life cycle assessment). The project was devotedmore » to support Lombardia Region in the drafting of the new waste management plan by applying a life cycle thinking perspective. The present paper mainly focuses on four Provinces in the Region, which were selected based on their peculiarities. Life cycle assessment (LCA) was adopted as the methodology to assess the current performance of the integrated waste management systems, to discuss strengths and weaknesses of each of them and to design their perspective evolution as of year 2020. Results show that despite a usual business approach that is beneficial to all the provinces, the introduction of technological and management improvements to the system provides in general additional energy and environmental benefits for all four provinces. The same improvements can be easily extended to the whole Region, leading to increased environmental benefits from the waste management sector, in line with the targets set by the European Union for 2020.« less
Barros, Vanessa; Frosi, Gabriella; Santos, Mariana; Ramos, Diego Gomes; Falcão, Hiram Marinho; Santos, Mauro Guida
2018-06-01
Plants suffer recurrent cycles of water deficit in semiarid regions and have several mechanisms to tolerate low water availability. Thus, arbuscular mycorrhizal fungi (AMF) can alleviate deleterious effects of stress. In this study, Cynophalla flexuosa plants, a woody evergreen species from semiarid, when associated with AMF were exposed to two consecutive cycles of water deficit. Leaf primary metabolism, specific leaf area (SLA), leaf construction cost (CC) and photosynthetic energy use efficiency (PEUE) were measured. The maximum stress occurred on seven days (cycle 1) and ten days (cycle 2) after suspending irrigation (photosynthesis close to zero). The rehydration was performed for three days after each maximum stress. In both cycles, plants submitted to water deficit showed reduced gas exchange and leaf relative water content. However, Drought + AMF plants had significantly larger leaf relative water content in cycle 2. At cycle 1, the SLA was larger in non-inoculated plants, while CC was higher in inoculated plants. At cycle 2, Drought + AMF treatment had lower CC and large SLA compared to control, and high PEUE compared to Drought plants. These responses suggest AMFs increase tolerance of C. flexuosa to recurrent water deficit, mainly in cycle 2, reducing the CC, promoting the improvement of SLA and PEUE, leading to higher photosynthetic area. Thus, our result emphasizes the importance of studies on recurrence of water deficit, a common condition in semiarid environments. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Effect of higher frequency on the classification of steady-state visual evoked potentials
NASA Astrophysics Data System (ADS)
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Objective. Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. Approach. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. Main results. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. Significance. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Effect of higher frequency on the classification of steady-state visual evoked potentials.
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Kristoffersen, Morten; Gundersen, Hilde; Leirdal, Stig; Iversen, Vegard V.
2014-01-01
Purpose: The aim of the present study was to investigate effects of low cadence training at moderate intensity on aerobic capacity, cycling performance, gross efficiency, freely chosen cadence, and leg strength in veteran cyclists. Method: Twenty-two well trained veteran cyclists [age: 47 ± 6 years, maximal oxygen consumption (VO2max): 57.9 ± 3.7 ml · kg−1 · min−1] were randomized into two groups, a low cadence training group and a freely chose cadence training group. Respiratory variables, power output, cadence and leg strength were tested before and after a 12 weeks training intervention period. The low cadence training group performed 12 weeks of moderate [73–82% of maximal heart rate (HRmax)] interval training (5 × 6 min) with a cadence of 40 revolutions per min (rpm) two times a week, in addition to their usual training. The freely chosen cadence group added 90 min of training at freely chosen cadence at moderate intensity. Results: No significant effects of the low cadence training on aerobic capacity, cycling performance, power output, cadence, gross efficiency, or leg strength was found. The freely chosen cadence group significantly improved both VO2max (58.9 ± 2.4 vs. 62.2 ± 3.2 ml · kg−1 · min−1), VO2 consumption at lactate threshold (49.4 ± 3.8 vs. 51.8 ± 3.5 ml · kg−1 · min−1) and during the 30 min performance test (52.8 ± 3.0 vs. 54.7 ± 3.5 ml · kg−1 · min−1), and power output at lactate threshold (284 ± 47 vs. 294 ± 48 W) and during the 30 min performance test (284 ± 42 vs. 297 ± 50 W). Moreover, a significant difference was seen when comparing the change in freely chosen cadence from pre- to post between the groups during the 30 min performance test (2.4 ± 5.0 vs. −2.7 ± 6.2). Conclusion: Twelve weeks of low cadence (40 rpm) interval training at moderate intensity (73–82% of HRmax) twice a week does not improve aerobic capacity, cycling performance or leg strength in highly trained veteran cyclists. However, adding training at same intensity (% of HRmax) and duration (90 min weekly) at freely chosen cadence seems beneficial for performance and physiological adaptations. PMID:24550843
NASA Astrophysics Data System (ADS)
Cho, Min Kyung; Park, Hee-Young; Lee, Hye Jin; Kim, Hyoung-Juhn; Lim, Ahyoun; Henkensmeier, Dirk; Yoo, Sung Jong; Kim, Jin Young; Lee, So Young; Park, Hyun S.; Jang, Jong Hyun
2018-04-01
Herein, we investigate the effects of catholyte feed method and anode binder content on the characteristics of anion exchange membrane water electrolysis (AEMWE) to construct a high-performance electrolyzer, revealing that the initial AEMWE performance is significantly improved by pre-feeding 0.5 M aqueous KOH to the cathode. The highest long-term activity during repeated voltage cycling is observed for AEMWE operation in the dry cathode mode, for which the best long-term performance among membrane electrode assemblies (MEAs) featuring polytetrafluoroethylene (PTFE) binder-impregnated (5-20 wt%) anodes is detected for a PTFE content of 20 wt%. MEAs with low PTFE content (5 and 9 wt%) demonstrate high initial performance, rapid performance decay, and significant catalyst loss from the electrode during long-term operation, whereas the MEA with 20 wt% PTFE allows stable water electrolysis for over 1600 voltage cycles. Optimization of cell operating conditions (i.e., operation in dry cathode mode at an optimum anode binder content following an initial solution feed) achieves an enhanced water splitting current density (1.07 A cm-2 at 1.8 V) and stable long-term AEMWE performance (0.01% current density reduction per voltage cycle).
The effects of solarization on the performance of a gas turbine
NASA Astrophysics Data System (ADS)
Homann, Christiaan; van der Spuy, Johan; von Backström, Theodor
2016-05-01
Various hybrid solar gas turbine configurations exist. The Stellenbosch University Solar Power Thermodynamic (SUNSPOT) cycle consists of a heliostat field, solar receiver, primary Brayton gas turbine cycle, thermal storage and secondary Rankine steam cycle. This study investigates the effect of the solarization of a gas turbine on its performance and details the integration of a gas turbine into a solar power plant. A Rover 1S60 gas turbine was modelled in Flownex, a thermal-fluid system simulation and design code, and validated against a one-dimensional thermodynamic model at design input conditions. The performance map of a newly designed centrifugal compressor was created and implemented in Flownex. The effect of the improved compressor on the performance of the gas turbine was evident. The gas turbine cycle was expanded to incorporate different components of a CSP plant, such as a solar receiver and heliostat field. The solarized gas turbine model simulates the gas turbine performance when subjected to a typical variation in solar resource. Site conditions at the Helio100 solar field were investigated and the possibility of integrating a gas turbine within this system evaluated. Heat addition due to solar irradiation resulted in a decreased fuel consumption rate. The influence of the additional pressure drop over the solar receiver was evident as it leads to decreased net power output. The new compressor increased the overall performance of the gas turbine and compensated for pressure losses incurred by the addition of solar components. The simulated integration of the solarized gas turbine at Helio100 showed potential, although the solar irradiation is too little to run the gas turbine on solar heat alone. The simulation evaluates the feasibility of solarizing a gas turbine and predicts plant performance for such a turbine cycle.
Castronovo, A. Margherita; Conforto, Silvia; Schmid, Maurizio; Bibbo, Daniele; D'Alessio, Tommaso
2013-01-01
Finding an optimum for the cycling performance is not a trivial matter, since the literature shows the presence of many controversial aspects. In order to quantify different levels of performance, several indexes have been defined and used in many studies, reflecting variations in physiological and biomechanical factors. In particular, indexes such as Gross Efficiency (GE), Net Efficiency (NE) and Delta Efficiency (DE) have been referred to changes in metabolic efficiency (EffMet), while the Indexes of Effectiveness (IE), defined over the complete crank revolution or over part of it, have been referred to variations in mechanical effectiveness (EffMech). All these indicators quantify the variations of different factors [i.e., muscle fibers type distribution, pedaling cadence, setup of the bicycle frame, muscular fatigue (MFat), environmental variables, ergogenic aids, psychological traits (PsychTr)], which, moreover, show high mutual correlation. In the attempt of assessing cycling performance, most studies in the literature keep all these factors separated. This may bring to misleading results, leaving unanswered the question of how to improve cycling performance. This work provides an overview on the studies involving indexes and factors usually related to performance monitoring and assessment in cycling. In particular, in order to clarify all those aspects, the mutual interactions among these factors are highlighted, in view of a global performance assessment. Moreover, a proposal is presented advocating for a model-based approach that considers all factors mentioned in the survey, including the mutual interaction effects, for the definition of an objective function E representing the overall effectiveness of a training program in terms of both EffMet and EffMech. PMID:23734130
Tang, Chunjuan; Wei, Xiujuan; Cai, Xinyin; An, Qinyou; Hu, Ping; Sheng, Jinzhi; Zhu, Jiexin; Chou, Shulei; Wu, Liming; Mai, Liqiang
2018-06-13
Sodium-ion batteries (SIBs) are considered as one of the most favorable alternative devices for sustainable development of modern society. However, it is still a big challenge to search for proper anode materials which have excellent cycling and rate performance. Here, zinc selenide microsphere and multiwalled carbon nanotube (ZnSe/MWCNT) composites are prepared via hydrothermal reaction and following grinding process. The performance of ZnSe/MWCNT composites as a SIB anode is studied for the first time. As a result, ZnSe/MWCNTs exhibit excellent rate capacity and superior cycling life. The capacity retains as high as 382 mA h g -1 after 180 cycles even at a current density of 0.5 A g -1 . The initial Coulombic efficiency of ZnSe/MWCNTs can reach 88% and nearby 100% in the following cycles. The superior electrochemical properties are attributed to continuous electron transport pathway, improved electrical conductivity, and excellent stress relaxation.
Roque, Matheus; Lattes, Karinna; Serra, Sandra; Solà, Ivan; Geber, Selmo; Carreras, Ramón; Checa, Miguel Angel
2013-01-01
To examine the available evidence to assess if cryopreservation of all embryos and subsequent frozen embryo transfer (FET) results in better outcomes compared with fresh transfer. Systematic review and meta-analysis. Centers for reproductive care. Infertility patient(s). An exhaustive electronic literature search in MEDLINE, EMBASE, and the Cochrane Library was performed through December 2011. We included randomized clinical trials comparing outcomes of IVF cycles between fresh and frozen embryo transfers. The outcomes of interest were ongoing pregnancy rate, clinical pregnancy rate, and miscarriage. We included three trials accounting for 633 cycles in women aged 27-33 years. Data analysis showed that FET resulted in significantly higher ongoing pregnancy rates and clinical pregnancy rates. Our results suggest that there is evidence that IVF outcomes may be improved by performing FET compared with fresh embryo transfer. This could be explained by a better embryo-endometrium synchrony achieved with endometrium preparation cycles. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Surface-modified Mg{sub 2}Ni-type negative electrode materials for Ni-MH battery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, N.; Luan, B.; Bradhurst, D.
1997-12-01
In order to further improve the electrode performance of Mg{sub 1.9}Y{sub 0.1}Ni{sub 0.9}Al{sub 0.1} alloy at ambient temperature, its surface was modified by an ultrasound pretreatment in the alkaline solution and microencapsulation with Ni-P coating. The effects of various surface modifications on the microstructure and electrochemical performance of the alloy electrodes were investigated and compared in this paper. It was found that the modification with ultrasound pretreatment significantly improved the electrocatalytic activity of the negative electrode and then reduced the overpotential of charging/discharging, resulting in a remarkable increase of electrode capacity and high-rate discharge capability but having little influence onmore » the cycle life. However, the electrode fabricated from the microencapsulated alloy powder showed a higher discharge capacity, better high-rate discharge capability and longer cycle life as well.« less
Hellard, Philippe; Scordia, Charlotte; Avalos, Marta; Mujika, Inigo; Pyne, David B
2017-10-01
Periodization of swim training in the final training phases prior to competition and its effect on performance have been poorly described. We modeled the relationships between the final 11 weeks of training and competition performance in 138 elite sprint, middle-distance, and long-distance swimmers over 20 competitive seasons. Total training load (TTL), strength training (ST), and low- to medium-intensity and high-intensity training variables were monitored. Training loads were scaled as a percentage of the maximal volume measured at each intensity level. Four training periods (meso-cycles) were defined: the taper (weeks 1 to 2 before competition), short-term (weeks 3 to 5), medium-term (weeks 6 to 8), and long-term (weeks 9 to 11). Mixed-effects models were used to analyze the association between training loads in each training meso-cycle and end-of-season major competition performance. For sprinters, a 10% increase between ∼20% and 70% of the TTL in medium- and long-term meso-cycles was associated with 0.07 s and 0.20 s faster performance in the 50 m and 100 m events, respectively (p < 0.01). For middle-distance swimmers, a higher TTL in short-, medium-, and long-term training yielded faster competition performance (e.g., a 10% increase in TTL was associated with improvements of 0.1-1.0 s in 200 m events and 0.3-1.6 s in 400 m freestyle, p < 0.01). For sprinters, a 60%-70% maximal ST load 6-8 weeks before competition induced the largest positive effects on performance (p < 0.01). An increase in TTL during the medium- and long-term preparation (6-11 weeks to competition) was associated with improved performance. Periodization plans should be adapted to the specialty of swimmers.
Production and uses of liquefied atmosphere (CO2) on Mars
NASA Technical Reports Server (NTRS)
Waldron, R. D.
1991-01-01
Carbon dioxide is universally accessible on Mars, and can be liquefied and separated from residual atmospheric gases by various compress-refrigeration cycles. Liquid CO2, stored under elevated pressures, can be used as a source of high pressure gas for nighttime power generation at a Martian base powered by solar energy during the daytime. Carbon dioxide can also be used for vehicular power. The extractable energy per unit mass of CO2 can exceed that of commercial lead-acid batteries for operating cycles without heat addition. Improved performance is possible using heat input from the ambient atmosphere or thermochemical agents. A unique vehicular application uses pressurized CO2 as a non-combustion low performance propellant for intermediate distance surface transportation. The thermodynamic properties of CO2 are presented with typical operating cycles for the application classes described above.
Electrochemical activity of Fe-MIL-100 as a positive electrode for Na-ion batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sava Gallis, Dorina F.; Pratt III, Harry D.; Anderson, Travis M.
2016-01-01
Here we investigate the electrochemical activity of metal-organic frameworks (MOFs) as positive electrodes for Na-ion batteries in coin cell configurations. The performance of Fe-MIL-100 material is highly dependent on the choice of sodium salt source, and electrolyte system. The overall capacity fades over many cycles, however the high Coulombic efficiency is maintained. This can be correlated with inaccessibility of active sites for Na intercalation, due to the increase of extra carbonaceous material inside the pores. High resolution synchrotron powder X-ray and pair distribution function analyses of the as-made and cycled electrodes reveal the structure maintains the long-range order with progressivemore » cycling. This finding suggests that careful consideration of all variables in battery components, and especially electrolyte selection can lead to greatly improved performances.« less
Improved Low Temperature Performance of Supercapacitors
NASA Technical Reports Server (NTRS)
Brandon, Erik J.; West, William C.; Smart, Marshall C.; Gnanaraj, Joe
2013-01-01
Low temperature double-layer capacitor operation enabled by: - Base acetonitrile / TEATFB salt formulation - Addition of low melting point formates, esters and cyclic ethers center dot Key electrolyte design factors: - Volume of co-solvent - Concentration of salt center dot Capacity increased through higher capacity electrodes: - Zeolite templated carbons - Asymmetric cell designs center dot Continuing efforts - Improve asymmetric cell performance at low temperature - Cycle life testing Motivation center dot Benchmark performance of commercial cells center dot Approaches for designing low temperature systems - Symmetric cells (activated carbon electrodes) - Symmetric cells (zeolite templated carbon electrodes) - Asymmetric cells (lithium titanate/activated carbon electrodes) center dot Experimental results center dot Summary
High-Efficiency Low-Cost Solar Receiver for Use Ina a Supercritical CO 2 Recompression Cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Shaun D.; Kesseli, James; Nash, James
This project has performed solar receiver designs for two supercritical carbon dioxide (sCO 2) power cycles. The first half of the program focused on a nominally 2 MWe power cycle, with a receiver designed for test at the Sandia Solar Thermal Test Facility. This led to an economical cavity-type receiver. The second half of the program focused on a 10 MWe power cycle, incorporating a surround open receiver. Rigorous component life and performance testing was performed in support of both receiver designs. The receiver performance objectives are set to conform to the US DOE goals of 6¢/kWh by 2020 .more » Key findings for both cavity-type and direct open receiver are highlighted below: A tube-based absorber design is impractical at specified temperatures, pressures and heat fluxes for the application; a plate-fin architecture however has been shown to meet performance and life targets; the $148/kW th cost of the design is significantly less than the SunShot cost target with a margin of 30%; the proposed receiver design is scalable, and may be applied to both modular cavity-type installations as well as large utility-scale open receiver installations; the design may be integrated with thermal storage systems, allowing for continuous high-efficiency electrical production during off-sun hours; costs associated with a direct sCO 2 receiver for a sCO 2 Brayton power cycle are comparable to those of a typical molten salt receiver; lifetimes in excess of the 90,000 hour goal are achievable with an optimal cell geometry; the thermal performance of the Brayton receiver is significantly higher than the industry standard, and enables at least a 30% efficiency improvement over the performance of the baseline steam-Rankine boiler/cycle system; brayton’s patent-pending quartz tube window provides a greater than five-percent efficiency benefit to the receiver by reducing both convection and radiation losses.« less
Charge-discharge characteristics of nickel/zinc battery with polymer hydrogel electrolyte
NASA Astrophysics Data System (ADS)
Iwakura, Chiaki; Murakami, Hiroki; Nohara, Shinji; Furukawa, Naoji; Inoue, Hiroshi
A new nickel/zinc (Ni/Zn) battery was assembled by using polymer hydrogel electrolyte prepared from cross-linked potassium poly(acrylate) and KOH aqueous solution, and its charge-discharge characteristics were investigated. The experimental Ni/Zn cell with the polymer hydrogel electrolyte exhibited well-defined charge-discharge curves and remarkably improved charge-discharge cycle performance, compared to that with a KOH aqueous solution. Moreover, it was found that dendritic growth hardly occurred on the zinc electrode surface during charge-discharge cycles in the polymer hydrogel electrolyte. These results indicate that the polymer hydrogel electrolyte can successfully be used in Ni/Zn batteries as an electrolyte with excellent performance.
The Electrochemical Performance of Silicon Nanoparticles in Concentrated Electrolyte.
Chang, Zeng-Hua; Wang, Jian-Tao; Wu, Zhao-Hui; Gao, Min; Wu, Shuai-Jin; Lu, Shi-Gang
2018-06-11
Silicon is a promising material for anodes in energy-storage devices. However, excessive growth of a solid-electrolyte interphase (SEI) caused by the severe volume change during the (de)lithiation processes leads to dramatic capacity fading. Here, we report a super-concentrated electrolyte composed of lithium bis(fluorosulfonyl)imide (LiFSI) and propylene carbonate (PC) with a molar ratio of 1:2 to improve the cycling performance of silicon nanoparticles (SiNPs). The SiNP electrode shows a remarkably improved cycling performance with an initial delithiation capacity of approximately 3000 mAh g -1 and a capacity of approximately 2000 mAh g -1 after 100 cycles, exhibiting about 6.8 times higher capacity than the cells with dilute electrolyte LiFSI-(PC) 8 . Raman spectra reveal that most of the PC solvent and FSI anions are complexed by Li + to form a specific solution structure like a fluid polymeric network. The reduction of FSI anions starts to play an important role owing to the increased concentration of contact ion pairs (CIPs) or aggregates (AGGs), which contribute to the formation of a more mechanically robust and chemically stable complex SEI layer. The complex SEI layer can effectively suppress the morphology evolution of silicon particles and self-limit the excessive growth, which mitigates the crack propagation of the silicon electrode and the deterioration of the kinetics. This study will provide a new direction for screening cycling-stable electrolytes for silicon-based electrodes. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Foster, Lancert E.; Saunders, John D., Jr.; Sanders, Bobby W.; Weir, Lois J.
2012-01-01
NASA is focused on technologies for combined cycle, air-breathing propulsion systems to enable reusable launch systems for access to space. Turbine Based Combined Cycle (TBCC) propulsion systems offer specific impulse (Isp) improvements over rocket-based propulsion systems in the subsonic takeoff and return mission segments along with improved safety. Among the most critical TBCC enabling technologies are: 1) mode transition from the low speed propulsion system to the high speed propulsion system, 2) high Mach turbine engine development and 3) innovative turbine based combined cycle integration. To address these challenges, NASA initiated an experimental mode transition task including analytical methods to assess the state-of-the-art of propulsion system performance and design codes. One effort has been the Combined-Cycle Engine Large Scale Inlet Mode Transition Experiment (CCE-LIMX) which is a fully integrated TBCC propulsion system with flowpath sizing consistent with previous NASA and DoD proposed Hypersonic experimental flight test plans. This experiment was tested in the NASA GRC 10 by 10-Foot Supersonic Wind Tunnel (SWT) Facility. The goal of this activity is to address key hypersonic combined-cycle engine issues including: (1) dual integrated inlet operability and performance issues-unstart constraints, distortion constraints, bleed requirements, and controls, (2) mode-transition sequence elements caused by switching between the turbine and the ramjet/scramjet flowpaths (imposed variable geometry requirements), and (3) turbine engine transients (and associated time scales) during transition. Testing of the initial inlet and dynamic characterization phases were completed and smooth mode transition was demonstrated. A database focused on a Mach 4 transition speed with limited off-design elements was developed and will serve to guide future TBCC system studies and to validate higher level analyses.
CF6 jet engine performance improvement: High pressure turbine roundness
NASA Technical Reports Server (NTRS)
Howard, W. D.; Fasching, W. A.
1982-01-01
An improved high pressure turbine stator reducing fuel consumption in current CF6-50 turbofan engines was developed. The feasibility of the roundness and clearance response improvements was demonstrated. Application of these improvements will result in a cruise SFC reduction of 0.22 percent for new engines. For high time engines, the improved roundness and response characteristics results in an 0.5 percent reduction in cruise SFC. A basic life capability of the improved HP turbine stator in over 800 simulated flight cycles without any sign of significant distress is shown.
Process design and economic analysis of the zinc selenide thermochemical hydrogen cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otsuki, H.H.; Krikorian, O.H.
1978-09-06
A detailed preliminary design for a hydrogen production plant has been developed based on an improved version of the ZnSe thermochemical cycle for decomposing water. In the latest version of the cycle, ZnCl/sub 2/ is converted directly to ZnO through high temperature steam hydrolysis. This eliminates the need for first converting ZnCl/sub 2/ to ZnSO/sub 4/ and also slightly reduces the overall heat requirement. Moreover, it broadens the temperature range over which prime heat is required and improves the coupling of the cycle with a nuclear reactor heat source. The ZnSe cycle is driven by a very-high-temperature nuclear reactor (VHTR)more » proposed by Westinghouse that provides a high-temperature (1283 K) helium working gas for process heat and power. The plant is sized to produce 27.3 Mg H/sub 2//h (60,000 lb H/sub 2//h) and requires specially designed equipment to perform the critical reaction steps in the cycle. We have developed conceptual designs for several of the important process steps to make cost estimates, and have obtained a cycle efficiency of about 40% and a hydrogen production cost of about $14/GJ. We believe that the cost is high because input data on reaction rates and equipment lifetimes have been conservatively estimated and the cycle parameters have not been optimized. Nonetheless, this initial analysis serves an important function in delineating areas in the cycle where additional research is needed to increase efficiency and reduce costs in a more advanced version of the cycle.« less
Fei, Huilong; Peng, Zhiwei; Yang, Yang; Li, Lei; Raji, Abdul-Rahman O; Samuel, Errol L G; Tour, James M
2014-07-11
LiFePO4 encapsulated in graphene nanoshells (LiFePO4@GNS) nanoparticles were synthesized by solid state reaction between graphene-coated Fe nanoparticles and LiH2PO4. The resulting nanocomposite was demonstrated to be a superior lithium-ion battery cathode with improved cycle and rate performances.
Discharge characteristics of 300 ampere-hour Ni-Zn traction cells
NASA Technical Reports Server (NTRS)
Ewashinka, J. G.
1979-01-01
Preliminary tests were performed on 300 amphere-hour nickel-zinc cells containing the Lewis improved inorganic-organic (I/O) separator. These cells also have other design features included to optimize performance and cycle life. The tests carried out were formation tests and characteristic discharge tests. Information obtained include case temperature and maximum power delivered.
Niu, Xiao-Qing; Wang, Xiu-Li; Xie, Dong; Wang, Dong-Huang; Zhang, Yi-Di; Li, Yi; Yu, Ting; Tu, Jiang-Ping
2015-08-05
Tailored sulfur cathode is vital for the development of a high performance lithium-sulfur (Li-S) battery. A surface modification on the sulfur/carbon composite would be an efficient strategy to enhance the cycling stability. Herein, we report a nickel hydroxide-modified sulfur/conductive carbon black composite (Ni(OH)2@S/CCB) as the cathode material for the Li-S battery through the thermal treatment and chemical precipitation method. In this composite, the sublimed sulfur is stored in the CCB, followed by a surface modification of Ni(OH)2 nanoparticles with size of 1-2 nm. As a cathode for the Li-S battery, the as-prepared Ni(OH)2@S/CCB electrode exhibits better cycle stability and higher rate discharge capacity, compared with the bare S/CCB electrode. The improved performance is largely due to the introduction of Ni(OH)2 surface modification, which can effectively suppress the "shuttle effect" of polysulfides, resulting in enhanced cycling life and higher capacity.
Sleep, performance, circadian rhythms, and light-dark cycles during two space shuttle flights
NASA Technical Reports Server (NTRS)
Dijk, D. J.; Neri, D. F.; Wyatt, J. K.; Ronda, J. M.; Riel, E.; Ritz-De Cecco, A.; Hughes, R. J.; Elliott, A. R.; Prisk, G. K.; West, J. B.;
2001-01-01
Sleep, circadian rhythm, and neurobehavioral performance measures were obtained in five astronauts before, during, and after 16-day or 10-day space missions. In space, scheduled rest-activity cycles were 20-35 min shorter than 24 h. Light-dark cycles were highly variable on the flight deck, and daytime illuminances in other compartments of the spacecraft were very low (5.0-79.4 lx). In space, the amplitude of the body temperature rhythm was reduced and the circadian rhythm of urinary cortisol appeared misaligned relative to the imposed non-24-h sleep-wake schedule. Neurobehavioral performance decrements were observed. Sleep duration, assessed by questionnaires and actigraphy, was only approximately 6.5 h/day. Subjective sleep quality diminished. Polysomnography revealed more wakefulness and less slow-wave sleep during the final third of sleep episodes. Administration of melatonin (0.3 mg) on alternate nights did not improve sleep. After return to earth, rapid eye movement (REM) sleep was markedly increased. Crewmembers on these flights experienced circadian rhythm disturbances, sleep loss, decrements in neurobehavioral performance, and postflight changes in REM sleep.
Quantification of the degradation of Ni-YSZ anodes upon redox cycling
NASA Astrophysics Data System (ADS)
Song, Bowen; Ruiz-Trejo, Enrique; Bertei, Antonio; Brandon, Nigel P.
2018-01-01
Ni-YSZ anodes for Solid Oxide Fuel Cells are vulnerable to microstructural damage during redox cycling leading to a decrease in the electrochemical performance. This study quantifies the microstructural changes as a function of redox cycles at 800 °C and associates it to the deterioration of the mechanical properties and polarisation resistance. A physically-based model is used to estimate the triple-phase boundary (TPB) length from impedance spectra, and satisfactorily matches the TPB length quantified by FIB-SEM tomography: within 20 redox cycles, the TPB density decreases from 4.63 μm-2 to 1.06 μm-2. Although the polarisation resistance increases by an order of magnitude after 20 cycles, after each re-reduction the electrode polarisation improves consistently due to the transient generation of Ni nanoparticles around the TPBs. Nonetheless, the long-term degradation overshadows this transient improvement due to the nickel agglomeration. In addition, FIB-SEM tomography reveals fractures along YSZ grain boundaries, Ni-YSZ detachment and increased porosity in the composite that lead to irreversible mechanical damage: the elastic modulus diminishes from 36.4 GPa to 20.2 GPa and the hardness from 0.40 GPa to 0.15 GPa. These results suggest that microstructural, mechanical and electrochemical properties are strongly interdependent in determining the degradation caused by redox cycling.
NASA Technical Reports Server (NTRS)
Barrett, Michael J.
2003-01-01
Performance expectations of closed-Brayton-cycle heat exchangers to be used in 100-kWe nuclear space power systems were forecast. Proposed cycle state points for a system supporting a mission to three of Jupiter s moons required effectiveness values for the heat-source exchanger, recuperator and rejection exchanger (gas cooler) of 0.98,0.95 and 0.97, respectively. Performance parameters such as number of thermal units (Nm), equivalent thermal conductance (UA), and entropy generation numbers (Ns) varied from 11 to 19,23 to 39 kWK, and 0.019 to 0.023 for some standard heat exchanger configurations. Pressure-loss contributions to entropy generation were significant; the largest frictional contribution was 114% of the heat-transfer irreversibility. Using conventional recuperator designs, the 0.95 effectiveness proved difficult to achieve without exceeding other performance targets; a metallic, plate-fin counterflow solution called for 15% more mass and 33% higher pressure-loss than the target values. Two types of gas-coolers showed promise. Single-pass counterflow and multipass cross-counterflow arrangements both met the 0.97 effectiveness requirement. Potential reliability-related advantages of the cross-countefflow design were noted. Cycle modifications, enhanced heat transfer techniques and incorporation of advanced materials were suggested options to reduce system development risk. Carbon-carbon sheeting or foam proved an attractive option to improve overall performance.
NASA Technical Reports Server (NTRS)
Barrett, Michael J.
2003-01-01
Performance expectations of closed-Brayton-cycle heat exchangers to be used in 100-k We nuclear space power systems were forecast. Proposed cycle state points for a system supporting a mission to three of Jupiter's moons required effectiveness values for the heat-source exchanger, recuperator and rejection exchanger (gas cooler) of 0.98, 0.95, and 0.97, respectively. Performance parameters such as number of thermal units (Ntu), equivalent thermal conductance (UA), and entropy generation numbers (Ns) varied from 11 to 19, 23 to 39 kW/K, and 0.019 to 0.023 for some standard heat exchanger configurations. Pressure-loss contributions to entropy generation were significant; the largest frictional contribution was 114% of the heat transfer irreversibility. Using conventional recuperator designs, the 0.95 effectiveness proved difficult to achieve without exceeding other performance targets; a metallic, plate-fin counterflow solution called for 15% more mass and 33% higher pressure-loss than the target values. Two types of gas-coolers showed promise. Single-pass counterflow and multipass cross-counterflow arrangements both met the 0.97 effectiveness requirement. Potential reliability-related advantages of the cross-counterflow design were noted. Cycle modifications, enhanced heat transfer techniques and incorporation of advanced materials were suggested options to reduce system development risk. Carbon-carbon sheeting or foam proved an attractive option to improve overall performance.
Development and application of basis database for materials life cycle assessment in china
NASA Astrophysics Data System (ADS)
Li, Xiaoqing; Gong, Xianzheng; Liu, Yu
2017-03-01
As the data intensive method, high quality environmental burden data is an important premise of carrying out materials life cycle assessment (MLCA), and the reliability of data directly influences the reliability of the assessment results and its application performance. Therefore, building Chinese MLCA database is the basic data needs and technical supports for carrying out and improving LCA practice. Firstly, some new progress on database which related to materials life cycle assessment research and development are introduced. Secondly, according to requirement of ISO 14040 series standards, the database framework and main datasets of the materials life cycle assessment are studied. Thirdly, MLCA data platform based on big data is developed. Finally, the future research works were proposed and discussed.
Separator for lithium-sulfur battery based on polymer blend membrane
NASA Astrophysics Data System (ADS)
Freitag, Anne; Stamm, Manfred; Ionov, Leonid
2017-09-01
In this work we report a novel way of reducing the polysulfide shuttle in lithium-sulfur batteries by a new separator material. Polyvinylsulfate potassium salt (PVSK) as polymeric additive is introduced into a polyvinylidene fluoride-hexafluoropropylene (PVdF-HFP) matrix membrane to improve the battery performance. PVSK is expected to lower the polysulfide mobility due to interaction with the sulfonic group. PVdF-HFP/PVSK blend membranes are prepared and an UV/Vis polysulfide diffusion test clearly demonstrates the positive effect of PVSK. Electrochemical testing reveals a significant improvement of cycling stability up to more than 200 cycles. In addition, the effect of separator porosity to the polysulfide shuttle is investigated with PVdF-HFP membranes of different porosity. A simple polysulfide diffusion test and potentiostatic charge/discharge cycling clearly demonstrate that low separator porosity is favorable in a lithium-sulfur cell.
NASA Technical Reports Server (NTRS)
Ott, Eric A.
2005-01-01
Scoping of shape changing airfoil concepts including both aerodynamic analysis and materials-related technology assessment effort was performed. Three general categories of potential components were considered-fan blades, booster and compressor blades, and stator airfoils. Based on perceived contributions to improving engine efficiency, the fan blade was chosen as the primary application for a more detailed assessment. A high-level aerodynamic assessment using a GE90-90B Block 4 engine cycle and fan blade geometry indicates that blade camber changes of approximately +/-4deg would be sufficient to result in fan efficiency improvements nearing 1 percent. Constraints related to flight safety and failed mode operation suggest that use of the baseline blade shape with actuation to the optimum cruise condition during a portion of the cycle would be likely required. Application of these conditions to the QAT fan blade and engine cycle was estimated to result in an overall fan efficiency gain of 0.4 percent.
Highly Conductive In-SnO2/RGO Nano-Heterostructures with Improved Lithium-Ion Battery Performance
NASA Astrophysics Data System (ADS)
Liu, Ying; Palmieri, Alessandro; He, Junkai; Meng, Yongtao; Beauregard, Nicole; Suib, Steven L.; Mustain, William E.
2016-05-01
The increasing demand of emerging technologies for high energy density electrochemical storage has led many researchers to look for alternative anode materials to graphite. The most promising conversion and alloying materials do not yet possess acceptable cycle life or rate capability. In this work, we use tin oxide, SnO2, as a representative anode material to explore the influence of graphene incorporation and In-doping to increase the electronic conductivity and concomitantly improve capacity retention and cycle life. It was found that the incorporation of In into SnO2 reduces the charge transfer resistance during cycling, prolonging life. It is also hypothesized that the increased conductivity allows the tin oxide conversion and alloying reactions to both be reversible, leading to very high capacity near 1200 mAh/g. Finally, the electrodes show excellent rate capability with a capacity of over 200 mAh/g at 10C.
NASA Technical Reports Server (NTRS)
Atli, K. C.; Karaman, I; Noebe, R. D.; Garg, A.; Chumlyakov, Y. I.; Kireeva, I. V.
2010-01-01
A Ti(50.5)Ni(24.5)Pd25 high-temperature shape memory alloy (HTSMA) is microalloyed with 0.5 at. pct scandium (Sc) to enhance its shape-memory characteristics, in particular, dimensional stability under repeated thermomechanical cycles. For both Ti(50.5)Ni(24.5)Pd25 and the Sc-alloyed material, differential scanning calorimetry is conducted for multiple cycles to characterize cyclic stability of the transformation temperatures. The microstructure is evaluated using electron microscopy, X-ray diffractometry, and wavelength dispersive spectroscopy. Isobaric thermal cycling experiments are used to determine transformation temperatures, dimensional stability, and work output as a function of stress. The Sc-doped alloy displays more stable shape memory response with smaller irrecoverable strain and narrower thermal hysteresis than the baseline ternary alloy. This improvement in performance is attributed to the solid solution hardening effect of Sc.
Breitung, Ben; Aguiló-Aguayo, Noemí; Bechtold, Thomas; Hahn, Horst; Janek, Jürgen; Brezesinski, Torsten
2017-10-12
Si holds great promise as an alloying anode material for Li-ion batteries with improved energy density because of its high theoretical specific capacity and favorable operation voltage range. However, the large volume expansion of Si during electrochemical reaction with Li and the associated adverse effects strongly limit its prospect for application. Here, we report on the use of three-dimensional instead of flat current collectors for high-capacity Si anodes in an attempt to mitigate the loss of electrical contact of active electrode regions as a result of structural disintegration with cycling. The current collectors were produced by technical embroidery and consist of interconnected Cu wires of diameter <150 µm. In comparison to Si/Li cells using a conventional Cu foil current collector, the embroidered microwire network-based cells show much enhanced capacity and reversibility due to a higher degree of tolerance to cycling.
Singh, Saurabh; Shinde, Nanasaheb M; Xia, Qi Xun; Gopi, Chandu V V M; Yun, Je Moon; Mane, Rajaram S; Kim, Kwang Ho
2017-10-14
Herein, we tailor the surface morphology of nickel-manganese-layered double hydroxide (NiMn-LDH) nanostructures on 3D nickel-foam via a step-wise cobalt (Co)-doping hydrothermal chemical process. At the 10% optimum level of Co-doping, we noticed a thriving tuned morphological pattern of NiMn-LDH nanostructures (NiCoMn-LDH (10%)) in terms of the porosity of the nanosheet (NS) arrays which not only improves the rate capability as well as cycling stability, but also demonstrates nearly two-fold specific capacitance enhancement compared to Co-free and other NiCoMn-LDH electrodes with a half-cell configuration in 3 M KOH, suggesting that Co-doping is indispensable for improving the electrochemical performance of NiMn-LDH electrodes. Moreover, when this high performing NiCoMn-LDH (10%) electrode is employed as a cathode material to fabricate an asymmetric supercapacitor (ASC) device with reduced graphene oxide (rGO) as an anode material, excellent energy storage performance (57.4 Wh kg -1 at 749.9 W kg -1 ) and cycling stability (89.4% capacitive retention even after 2500 cycles) are corroborated. Additionally, we present a demonstration of illuminating a light emitting diode for 600 s with the NiCoMn-LDH (10%)//rGO ASC device, evidencing the potential of the NiCoMn-LDH (10%) electrode in fabricating energy storage devices.
Shi, Huimin; Zhang, Shi; Zhu, Xupeng; Liu, Yu; Wang, Tao; Jiang, Tian; Zhang, Guanhua; Duan, Huigao
2017-10-25
The {001}-faceted anatase TiO 2 micro-/nanocrystals have been widely investigated for enhancing the photocatalysis and photoelectrochemical performance of TiO 2 nanostructures, but their practical applications still require improved energy conversion efficiency under solar-light and enhanced cycling stability. In this work, we demonstrate the controlled growth of ultrathin {001}-faceted anatase TiO 2 nanosheets on flexible carbon cloth for enhancing the cycling stability, and the solar-light photocatalytic performance of the synthesized TiO 2 nanosheets can be significantly improved by decorating with vapor-phase-deposited uniformly distributed plasmonic gold nanoparticles. The fabricated Au-TiO 2 hybrid system shows an 8-fold solar-light photocatalysis enhancement factor in photodegrading Rhodamine B, a high photocurrent density of 300 μA cm -2 under the illumination of AM 1.5G, and 100% recyclability under a consecutive long-term cycling measurement. Combined with electromagnetic simulations and systematic control experiments, it is believed that the tandem-type separation and transition of plasmon-induced hot electrons from Au nanoparticles to the {001} facet of anatase TiO 2 , and then to the neighboring {101} facet, is responsible for the enhanced solar-light photochemical performance of the hybrid system. The Au-TiO 2 nanosheet system addresses well the problems of the limited solar-light response of anatase TiO 2 and fast recombination of photogenerated electron-hole pairs, representing a promising high-performance recyclable solar-light-responding system for practical photocatalytic reactions.
A new boil-off gas re-liquefaction system for LNG carriers based on dual mixed refrigerant cycle
NASA Astrophysics Data System (ADS)
Tan, Hongbo; Shan, Siyu; Nie, Yang; Zhao, Qingxuan
2018-06-01
A new boil-off gas (BOG) re-liquefaction system for LNG carriers has been proposed to improve the system energy efficiency. Two cascade mixed refrigerant cycles (or dual mixed refrigerant cycle, DMR) are used to provide the cooling capacity for the re-liquefaction of BOG. The performance of the new system is analysed on the basis of the thermodynamic data obtained in the process simulation in Aspen HYSYS software. The results show that the power consumed in the BOG compressor and the high-temperature mixed refrigerant compressor could be saved greatly due to the reduced mass flow rates of the processed fluids. Assuming the re-liquefaction capacity of the investigated system is 4557.6 kg/h, it is found that the total power consumption can be reduced by 25%, from 3444 kW in the existing system to 2585.8 kW in the proposed system. The coefficient of performance (COP) of 0.25, exergy efficiency of 41.3% and the specific energy consumption (SEC) of 0.589 kWh/kg(LNG) could be achieved in the new system. It exhibits 33% of improvement in the COP and exergy efficiency in comparison with the corresponding values of the existing system. It indicates that employing the DMR based BOG re-liquefaction system could improve the system energy efficiency of LNG carriers substantially.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xing; Zhang, Kangjia; Wang, Mingshan
2018-02-28
Trace amount of Zirconium (Zr) has been adopted to modify the crystal structure and surface of the Ni-rich LiNi0.8Co0.1Mn0.1O2 (NCM811) cathode material. During cycling at 1.0C, the Zr-modified NCM811 shows an improved capacity retention of 92% after 100 cycles, higher than 75% for pristine NMC811. In addition, the Zr-modified NCM811 is capable of delivering a discharge capacity of 107 mAh g-1 at 10.0C rate, much higher than 28 mAh g-1 delivered by pristine material. These improved electrochemical performances are ascribed to the dual functions of Zr modification. On one hand, part of the Zr enters the crystal lattice, which ismore » beneficial for reducing the Li/Ni cation mixing and enhancing the crystal stability of the cathode. On the other hand, the rest of the Zr forms a 1~2 nm thick coating layer on the surface of the NCM811 cathode, which effectively prevents the direct contact between NCM and the electrolyte, thus suppressing the detrimental interfacial reactions. Therefore, the Zr-modified LiNi0.8Co0.1Mn0.1O2 exhibited significantly enhanced cycling stability and charging/discharging rate capability in comparison with the untreated counterpart.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Hongyu; Ahmad, Mashkoor, E-mail: mashkoorahmad2003@yahoo.com; Luo, Jun
Graphical abstract: The synthesized SnS{sub 2} nanoflakes decorated multiwalled carbon nanotubes hybrid structures exhibit large reversible capacity, superior cycling performance, and good rate capability as compared to pure SnS{sub 2} nanoflakes. - Highlights: • Synthesis of SnS{sub 2} nanoflakes decorated multiwalled carbon nanotubes hybrid structures. • Simple solution-phase approach. • Morphology feature of SnS{sub 2}. • Enhanced performance as Li-ion batteries. - Abstract: SnS{sub 2} nanoflakes decorated multiwalled carbon nanotubes (MWCNTs) hybrid structures are directly synthesized via a simple solution-phase approach. The as-prepared SnS{sub 2}/MWCNTs structures are investigated as anode materials for Li-ion batteries as compared with SnS{sub 2} nanoflakes.more » It has been found that the composite structure exhibit excellent lithium storage performance with a large reversible capacity, superior cycling performance, and good rate capability as compared to pure SnS{sub 2} nanoflakes. The first discharge and charge capacities have been found to be 1416 and 518 mA h g{sup −1} for SnS{sub 2}/MWCNTs composite electrodes at a current density of 100 mA g{sup −1} between 5 mV and 1.15 V versus Li/Li{sup +}. A stable reversible capacity of ∼510 mA h g{sup −1} is obtained for 50 cycles. The improved electrochemical performance may be attributed to the flake-morphology feature of SnS{sub 2} and the addition of MWCNTs that can hinder the agglomeration of the active materials and improve the conductivity of the composite electrode simultaneously.« less
Cycle life test. [of secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1977-01-01
Statistical information concerning cell performance characteristics and limitations of secondary spacecraft cells is presented. Weaknesses in cell design as well as battery weaknesses encountered in various satellite programs are reported. Emphasis is placed on improving the reliability of space batteries.
Abrasion-resistant concrete mix designs for precast bridge deck panels.
DOT National Transportation Integrated Search
2010-08-01
The report documents laboratory investigations undertaken to develop high performance concrete (HPC) for precast and pre-stressed bridge deck components that would reduce the life-cycle cost of bridges by improving the studded tire wear (abrasion) re...
Aerothermal modeling. Executive summary
NASA Technical Reports Server (NTRS)
Kenworthy, M. K.; Correa, S. M.; Burrus, D. L.
1983-01-01
One of the significant ways in which the performance level of aircraft turbine engines has been improved is by the use of advanced materials and cooling concepts that allow a significant increase in turbine inlet temperature level, with attendant thermodynamic cycle benefits. Further cycle improvements have been achieved with higher pressure ratio compressors. The higher turbine inlet temperatures and compressor pressure ratios with corresponding higher temperature cooling air has created a very hostile environment for the hot section components. To provide the technology needed to reduce the hot section maintenance costs, NASA has initiated the Hot Section Technology (HOST) program. One key element of this overall program is the Aerothermal Modeling Program. The overall objective of his program is to evolve and validate improved analysis methods for use in the design of aircraft turbine engine combustors. The use of such combustor analysis capabilities can be expected to provide significant improvement in the life and durability characteristics of both combustor and turbine components.
Enhanced Endurance Performance by Periodization of Carbohydrate Intake: "Sleep Low" Strategy.
Marquet, Laurie-Anne; Brisswalter, Jeanick; Louis, Julien; Tiollier, Eve; Burke, Louise M; Hawley, John A; Hausswirth, Christophe
2016-04-01
We investigated the effect of a chronic dietary periodization strategy on endurance performance in trained athletes. Twenty-one triathletes (V˙O2max: 58.7 ± 5.7 mL·min(-1)·kg(-1)) were divided into two groups: a "sleep-low" (SL) (n = 11) and a control (CON) group (n = 10) consumed the same daily carbohydrate (CHO) intake (6 g·kg(-1)·d(-1)) but with different timing over the day to manipulate CHO availability before and after training sessions. The SL strategy consisted of a 3-wk training-diet intervention comprising three blocks of diet-exercise manipulations: 1) "train-high" interval training sessions in the evening with high-CHO availability, 2) overnight CHO restriction ("sleeping-low"), and 3) "train-low" sessions with low endogenous and exogenous CHO availability. The CON group followed the same training program but with high CHO availability throughout training sessions (no CHO restriction overnight, training sessions with exogenous CHO provision). There was a significant improvement in delta efficiency during submaximal cycling for SL versus CON (CON, +1.4% ± 9.3%; SL, +11% ± 15%, P < 0.05). SL also improved supramaximal cycling to exhaustion at 150% of peak aerobic power (CON, +1.63% ± 12.4%; SL, +12.5% ± 19.0%; P = 0.06) and 10-km running performance (CON, -0.10% ± 2.03%; SL, -2.9% ± 2.15%; P < 0.05). Fat mass was decreased in SL (CON, -2.6 ± 7.4; SL, -8.5% ± 7.4% before; P < 0.01), but not lean mass (CON, -0.22 ± 1.0; SL, -0.16% ± 1.7% PRE). Short-term periodization of dietary CHO availability around selected training sessions promoted significant improvements in submaximal cycling economy, as well as supramaximal cycling capacity and 10-km running time in trained endurance athletes.
Reduced Graphene Oxide-Wrapped FeS2 Composite as Anode for High-Performance Sodium-Ion Batteries
NASA Astrophysics Data System (ADS)
Wang, Qinghong; Guo, Can; Zhu, Yuxuan; He, Jiapeng; Wang, Hongqiang
2018-06-01
Iron disulfide is considered to be a potential anode material for sodium-ion batteries due to its high theoretical capacity. However, its applications are seriously limited by the weak conductivity and large volume change, which results in low reversible capacity and poor cycling stability. Herein, reduced graphene oxide-wrapped FeS2 (FeS2/rGO) composite was fabricated to achieve excellent electrochemical performance via a facile two-step method. The introduction of rGO effectively improved the conductivity, BET surface area, and structural stability of the FeS2 active material, thus endowing it with high specific capacity, good rate capability, as well as excellent cycling stability. Electrochemical measurements show that the FeS2/rGO composite had a high initial discharge capacity of 1263.2 mAh g-1 at 100 mA g-1 and a high discharge capacity of 344 mAh g-1 at 10 A g-1, demonstrating superior rate performance. After 100 cycles at 100 mA g-1, the discharge capacity remained at 609.5 mAh g-1, indicating the excellent cycling stability of the FeS2/rGO electrode.
NASA Astrophysics Data System (ADS)
Liu, Wanying; Zhu, Yabo; Chen, Zhiyan; Lei, Jia; Feng, Peizhong
2018-05-01
We generated multilayer black phosphorus (MBP) as a precipitate in centrifugation under 3000 rpm for 25 min, preceded by liquid exfoliation, in which saturated sodium hydroxide (NaOH(s)) was added as an exfoliation auxiliary. The MBP exfoliated with NaOH(s) was characterized by scanning electron microscope, energy dispersive x-ray detector, x-ray diffraction, x-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. Its electrochemical performance was investigated by cyclic voltammetry, charge/discharge and electrochemical impedance spectroscopy. It was found that the appropriate amount of NaOH(s) can make MBP present a ladder-shaped structure or plackets on the layer edge, which may provide more active sites and channels for charge storage to improve its electrochemical performance. The specific capacitance of MBP samples exfoliated with appropriate amounts of NaOH(s) can quickly enter a relatively stable range of 110-90 F/g after the 75th cycle, and finally stabilize at about 90 F/g after thousands of cycles under the current density of 2 A/g, which demonstrates their good stability in the range of long charge/discharge cycles. MBP exhibits double-layer capacitance properties.
NASA Astrophysics Data System (ADS)
Kumar, Pushpendra; Wu, Feng-Yu; Hu, Lung-Hao; Ali Abbas, Syed; Ming, Jun; Lin, Chia-Nan; Fang, Jason; Chu, Chih-Wei; Li, Lain-Jong
2015-04-01
Elementary sulphur (S) has been shown to be an excellent cathode material in energy storage devices such as Li-S batteries owing to its very high capacity. The major challenges associated with the sulphur cathodes are structural degradation, poor cycling performance and instability of the solid-electrolyte interphase caused by the dissolution of polysulfides during cycling. Tremendous efforts made by others have demonstrated that encapsulation of S materials improves their cycling performance. To make this approach practical for large scale applications, the use of low-cost technology and materials has become a crucial and new focus of S-based Li-ion batteries. Herein, we propose to use a low temperature spraying process to fabricate graphene/S electrode material, where the ink is composed of graphene flakes and the micron-sized S particles prepared by grinding of low-cost S powders. The S particles are found to be well hosted by highly conductive graphene flakes and consequently superior cyclability (~70% capacity retention after 250 cycles), good coulombic efficiency (~98%) and high capacity (~1500 mA h g-1) are obtained. The proposed approach does not require high temperature annealing or baking; hence, another great advantage is to make flexible Li-ion batteries. We have also demonstrated two types of flexible batteries using sprayed graphene/S electrodes.Elementary sulphur (S) has been shown to be an excellent cathode material in energy storage devices such as Li-S batteries owing to its very high capacity. The major challenges associated with the sulphur cathodes are structural degradation, poor cycling performance and instability of the solid-electrolyte interphase caused by the dissolution of polysulfides during cycling. Tremendous efforts made by others have demonstrated that encapsulation of S materials improves their cycling performance. To make this approach practical for large scale applications, the use of low-cost technology and materials has become a crucial and new focus of S-based Li-ion batteries. Herein, we propose to use a low temperature spraying process to fabricate graphene/S electrode material, where the ink is composed of graphene flakes and the micron-sized S particles prepared by grinding of low-cost S powders. The S particles are found to be well hosted by highly conductive graphene flakes and consequently superior cyclability (~70% capacity retention after 250 cycles), good coulombic efficiency (~98%) and high capacity (~1500 mA h g-1) are obtained. The proposed approach does not require high temperature annealing or baking; hence, another great advantage is to make flexible Li-ion batteries. We have also demonstrated two types of flexible batteries using sprayed graphene/S electrodes. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00885a
Precooling and Warm-Up Effects on Time Trial Cycling During Heat Stress.
Al-Horani, Ramzi A; Wingo, Jonathan E; Ng, Jason; Bishop, Phillip; Richardson, Mark
2018-02-01
Heat stress limits endurance exercise performance. Combining precooling and warm-up prior to endurance exercise in the heat may exploit the benefits of both strategies while avoiding the potential negative consequences of each. This study tested the hypothesis that precooling combined with warm-up improves time trial cycling performance in the heat relative to either treatment alone. Nine healthy men completed three 16.1-km time trials in 33°C after: 1) precooling (ice slurry and ice vest) alone (PREC); 2) warm-up alone (WU); or 3) PREC plus WU (COMBO). Tre was lower after PREC compared to WU throughout exercise and lower than COMBO for the first 12 km; COMBO was lower than WU for the first 4 km. Tsk during PREC was lower than COMBO and WU for the first 8 km, and lower in COMBO than WU for the first 4 km. PREC lowered pre-exercise heart rate relative to COMBO and WU (68 ± 10, 106 ± 12, 101 ± 13 bpm, respectively), but it increased similarly during exercise. Local sweat rate (SR) was lower in PREC (0.1 ± 0.1 mg · cm-2 · min-1) than COMBO (0.5 ± 0.2 mg · cm-2 · min-1) and WU (0.6 ± 0.2 mg · cm-2 · min-1) for the first 4 km. Treatments did not differentially affect performance (PREC = 31.9 ± 1.9 min, COMBO = 32.6 ± 2.7 min, WU = 33.1 ± 2.9 min). We conclude precooling alone or with warm-up mitigated thermal strain during exercise, but did not significantly improve 16.1-km cycling time trial performance.Al-horani RA, Wingo JE, Ng J, Bishop P, Richardson M. Precooling and warm-up effects on time trial cycling during heat stress. Aerosp Med Hum Perform. 2018; 89(2):87-93.
National Combustion Code: Parallel Implementation and Performance
NASA Technical Reports Server (NTRS)
Quealy, A.; Ryder, R.; Norris, A.; Liu, N.-S.
2000-01-01
The National Combustion Code (NCC) is being developed by an industry-government team for the design and analysis of combustion systems. CORSAIR-CCD is the current baseline reacting flow solver for NCC. This is a parallel, unstructured grid code which uses a distributed memory, message passing model for its parallel implementation. The focus of the present effort has been to improve the performance of the NCC flow solver to meet combustor designer requirements for model accuracy and analysis turnaround time. Improving the performance of this code contributes significantly to the overall reduction in time and cost of the combustor design cycle. This paper describes the parallel implementation of the NCC flow solver and summarizes its current parallel performance on an SGI Origin 2000. Earlier parallel performance results on an IBM SP-2 are also included. The performance improvements which have enabled a turnaround of less than 15 hours for a 1.3 million element fully reacting combustion simulation are described.
Chang, Hsiu Chen; Lu, Chin Song; Chiou, Wei Da; Chen, Chiung Chu; Weng, Yi Hsin; Chang, Ya Ju
2018-04-01
The effects of high-intensity cycling as an adjuvant therapy for early-stage Parkinson's disease (PD) were highlighted recently. However, patients experience difficulties in maintaining these cycling training programs. The present study investigated the efficacy of cycling at a mild-to-moderate intensity in early-stage PD. Thirteen PD patients were enrolled for 16 serial cycling sessions over a 2-month period. Motor function was assessed using the Unified Parkinson's Disease Rating Scale part III (UPDRS III) and Timed Up and Go (TUG) test as primary outcomes. The Montreal Cognitive Assessment (MoCA), modified Hoehn and Yahr Stage (mHYS), total UPDRS, Falls Efficacy Scale, New Freezing of Gait Questionnaire, Schwab and England Activities of Daily Living, 39-item Parkinson's Disease Questionnaire, Patient Global Impression of Change, and gait performance were assessed as secondary outcomes. The age and the age at onset were 59.67±7.24 and 53.23±10.26 years (mean±SD), respectively. The cycling cadence was 53.27±8.92 revolutions per minute. The UPDRS III score improved significantly after 8 training sessions (p=0.011) and 16 training sessions (T2) (p=0.001) in the off-state, and at T2 (p=0.004) in the on-state compared to pretraining (T0). The TUG duration was significantly shorter at T2 than at T0 (p<0.05). The findings of MoCA, total UPDRS, double limb support time, and mHYS (in both the off- and on-states) also improved significantly at T2. Our pioneer study has demonstrated that a low-intensity progressive cycling exercise can improve motor function in PD, especially akinesia. The beneficial effects were similar to those of high-intensity rehabilitation programs. Copyright © 2018 Korean Neurological Association.
Testing of a heat pump clothes dryer. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, D.; Dieckmann, J.; Mallory, D.
1995-05-01
The integration of a heat pump heat source into a clothes dryer has been investigated by several U.S. and foreign appliance developers and manufacturers but no commercial or residential heat pump clothes dryers are currently available in North America. The objectives of this effort were to: (1) Evaluate a heat pump dryer prototype relative to residential dryer performance tests. (2) Quantify the product limitations. (3) Suggest design changes that would reduce the impact of the limitations or that have a positive impact on the benefits. (4) Position the product relative to utility DSM/IRP opportunities (e.g., reduced connected load, or energymore » conservation). (5) Develop preliminary cost data The program evaluated the performance of a prototype closed-cycle heat pump clothes dryer designed and built by the Nyle Corporation. The prototype design goals were: (1) Drying times equivalent to a conventional electric clothes dryer. (2) 60% reduction in energy consumption. (3) Effective lint removal (to prevent coil fouling). (4) Cool-down mode performance similar to conventional dryer. (5) 20 lb load capacity. (6) Low temperature dry for reduced clothes wrinkle. Test results indicated that the closed-cycle heat pump met some of the above mentioned goals but it fell short with respect to energy savings and dry time. Performance improvement recommendations were developed for the closed-cycle dryer approach. In addition, the closed-cycle design potential was compared to an open-cycle heat pump dryer configuration.« less
Post2 End-to-End Descent and Landing Simulation for ALHAT Design Analysis Cycle 2
NASA Technical Reports Server (NTRS)
Davis, Jody L.; Striepe, Scott A.; Maddock, Robert W.; Johnson, Andrew E.; Paschall, Stephen C., II
2010-01-01
The ALHAT project is an agency-level program involving NASA centers, academia, and industry, with a primary goal to develop a safe, autonomous, precision-landing system for robotic and crew-piloted lunar and planetary descent vehicles. POST2 is used as the 6DOF descent and landing trajectory simulation for determining integrated system performance of ALHAT landing-system models and lunar environment models. This paper presents updates in the development of the ALHAT POST2 simulation, as well as preliminary system performance analysis for ALDAC-2 used for the testing and assessment of ALHAT system models. The ALDAC-2 POST2 Monte Carlo simulation results have been generated and focus on HRN model performance with the fully integrated system, as well performance improvements of AGNC and TSAR model since the previous design analysis cycle
Mou, Jirong; Deng, Yunlong; Song, Zhicui; Zheng, Qiaoji; Lam, Kwok Ho; Lin, Dunmin
2018-05-22
High-voltage LiNi0.5Mn1.5O4 is a promising cathode candidate for lithium-ion batteries (LIBs) due to its considerable energy density and power density, but the material generally undergoes serious capacity fading caused by side reactions between the active material and organic electrolyte. In this work, Li+-conductive Li2SnO3 was coated on the surface of LiNi0.5Mn1.5O4 to protect the cathode against the attack of HF, mitigate the dissolution of Mn ions during cycling and improve the Li+ diffusion coefficient of the materials. Remarkable improvement in cycling stability and rate performance has been achieved in Li2SnO3-coated LiNi0.5Mn1.5O4. The 1.0 wt% Li2SnO3-coated LiNi0.5Mn1.5O4 cathode exhibits excellent cycling stability with a capacity retention of 88.2% after 150 cycles at 0.1 C and rate capability at high discharge rates of 5 C and 10 C, presenting discharge capacities of 119.5 and 112.2 mAh g-1, respectively. In particular, a significant improvement in cycling stability at 55 °C is obtained after the coating of 1.0 wt% Li2SnO3, giving a capacity retention of 86.8% after 150 cycles at 1 C and 55 °C. The present study provides a significant insight into the effective protection of Li-conductive coating materials for a high-voltage LiNi0.5Mn1.5O4 cathode material.
Integrated manufacturing approach to attain benchmark team performance
NASA Astrophysics Data System (ADS)
Chen, Shau-Ron; Nguyen, Andrew; Naguib, Hussein
1994-09-01
A Self-Directed Work Team (SDWT) was developed to transfer a polyimide process module from the research laboratory to our wafer fab facility for applications in IC specialty devices. The SDWT implemented processes and tools based on the integration of five manufacturing strategies for continuous improvement. These were: Leadership Through Quality (LTQ), Total Productive Maintenance (TMP), Cycle Time Management (CTM), Activity-Based Costing (ABC), and Total Employee Involvement (TEI). Utilizing these management techniques simultaneously, the team achieved six sigma control of all critical parameters, increased Overall Equipment Effectiveness (OEE) from 20% to 90%, reduced cycle time by 95%, cut polyimide manufacturing cost by 70%, and improved its overall team member skill level by 33%.
Lithium ion rechargeable systems studies
NASA Astrophysics Data System (ADS)
Levy, Samuel C.; Lasasse, Robert R.; Cygan, Randall T.; Voigt, James A.
Lithium ion systems, although relatively new, have attracted much interest worldwide. Their high energy density, long cycle life and relative safety, compared with metallic lithium rechargeable systems, make them prime candidates for powering portable electronic equipment. Although lithium ion cells are presently used in a few consumer devices, e.g., portable phones, camcorders, and laptop computers, there is room for considerable improvement in their performance. Specific areas that need to be addressed include: (1) carbon anode-increase reversible capacity, and minimize passivation; (2) cathode-extend cycle life, improve rate capability, and increase capacity. There are several programs ongoing at Sandia National Laboratories which are investigating means of achieving the stated objectives in these specific areas. This paper will review these programs.
An N+3 Technology Level Reference Propulsion System
NASA Technical Reports Server (NTRS)
Jones, Scott M.; Haller, William J.; Tong, Michael To-Hing
2017-01-01
An N+3 technology level engine, suitable as a propulsion system for an advanced single-aisle transport, was developed as a reference cycle for use in technology assessment and decision-making efforts. This reference engine serves three main purposes: it provides thermodynamic quantities at each major engine station, it provides overall propulsion system performance data for vehicle designers to use in their analyses, and it can be used for comparison against other proposed N+3 technology-level propulsion systems on an equal basis. This reference cycle is meant to represent the expected capability of gas turbine engines in the N+3 timeframe given reasonable extrapolations of technology improvements and the ability to take full advantage of those improvements.
Phase VI Glove Durability Testing
NASA Technical Reports Server (NTRS)
Mitchell, Kathryn
2011-01-01
The current state-of-the-art space suit gloves, the Phase VI gloves, have an operational life of 25 -- 8 hour Extravehicular Activities (EVAs) in a dust free, manufactured microgravity EVA environment. Future planetary outpost missions create the need for space suit gloves which can endure up to 90 -- 8 hour traditional EVAs or 576 -- 45 minute suit port-based EVAs in a dirty, uncontrolled planetary environment. Prior to developing improved space suit gloves for use in planetary environments, it is necessary to understand how the current state-of-the-art performs in these environments. The Phase VI glove operational life has traditionally been certified through cycle testing consisting of International Space Station (ISS)-based EVA tasks in a clean environment, and glove durability while performing planetary EVA tasks in a dirty environment has not previously been characterized. Testing was performed in the spring of 2010 by the NASA Johnson Space Center (JSC) Crew and Thermal Systems Division (CTSD) to characterize the durability of the Phase VI Glove and identify areas of the glove design which need improvement to meet the requirements of future NASA missions. Lunar simulant was used in this test to help replicate the dirty lunar environment, and generic planetary surface EVA tasks were performed during testing. A total of 50 manned, pressurized test sessions were completed in the Extravehicular Mobility Unit (EMU) using one pair of Phase VI gloves as the test article. The 50 test sessions were designed to mimic the total amount of pressurized cycling the gloves would experience over a 6 month planetary outpost mission. The gloves were inspected periodically throughout testing, to assess their condition at various stages in the test and to monitor the gloves for failures. Additionally, motion capture and force data were collected during 18 of the 50 test sessions to assess the accuracy of the cycle model predictions used in testing and to feed into the development of improved cycle model tables. This paper provides a detailed description of the test hardware and methodology, shares the results of the testing, and provides recommendations for future work.
Validation test of advanced technology for IPV nickel-hydrogen flight cells: Update
NASA Technical Reports Server (NTRS)
Smithrick, John J.; Hall, Stephen W.
1992-01-01
Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the low-earth-orbit (LEO) cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. An advanced 125 Ah IPV nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. The advanced cell design is in the process of being validated using real time LEO cycle life testing of NWSC, Crane, Indiana. An update of validation test results confirming this technology is presented.
Parallel recovery of consciousness and sleep in acute traumatic brain injury.
Duclos, Catherine; Dumont, Marie; Arbour, Caroline; Paquet, Jean; Blais, Hélène; Menon, David K; De Beaumont, Louis; Bernard, Francis; Gosselin, Nadia
2017-01-17
To investigate whether the progressive recuperation of consciousness was associated with the reconsolidation of sleep and wake states in hospitalized patients with acute traumatic brain injury (TBI). This study comprised 30 hospitalized patients (age 29.1 ± 13.5 years) in the acute phase of moderate or severe TBI. Testing started 21.0 ± 13.7 days postinjury. Consciousness level and cognitive functioning were assessed daily with the Rancho Los Amigos scale of cognitive functioning (RLA). Sleep and wake cycle characteristics were estimated with continuous wrist actigraphy. Mixed model analyses were performed on 233 days with the RLA (fixed effect) and sleep-wake variables (random effects). Linear contrast analyses were performed in order to verify if consolidation of the sleep and wake states improved linearly with increasing RLA score. Associations were found between scores on the consciousness/cognitive functioning scale and measures of sleep-wake cycle consolidation (p < 0.001), nighttime sleep duration (p = 0.018), and nighttime fragmentation index (p < 0.001). These associations showed strong linear relationships (p < 0.01 for all), revealing that consciousness and cognition improved in parallel with sleep-wake quality. Consolidated 24-hour sleep-wake cycle occurred when patients were able to give context-appropriate, goal-directed responses. Our results showed that when the brain has not sufficiently recovered a certain level of consciousness, it is also unable to generate a 24-hour sleep-wake cycle and consolidated nighttime sleep. This study contributes to elucidating the pathophysiology of severe sleep-wake cycle alterations in the acute phase of moderate to severe TBI. © 2016 American Academy of Neurology.
Lanferdini, Fábio J; Bini, Rodrigo R; Baroni, Bruno M; Klein, Kelli D; Carpes, Felipe P; Vaz, Marco A
2018-01-01
Evidence indicates that low-level laser therapy (LLLT) minimizes fatigue effects on muscle performance. However, the ideal LLLT dosage to improve athletes'performance during sports activities such as cycling is still unclear. Therefore, the goal of this study was to investigate the effects of different LLLT dosages on cyclists'performance in time-to-exhaustion tests. In addition, the effects of LLLT on the frequency content of the EMG signals to assess fatigue mechanisms were examined. Twenty male competitive cyclists participated in a crossover, randomized, double-blind, placebo-controlled trial. They performed an incremental cycling test to exhaustion (on day 1) followed by 4 time-to-exhaustion tests (on days 2-5) at their individual maximal power output. Before each time-to-exhaustion test, different dosages of LLLT (135, 270, and 405 J/thigh, respectively) or placebo were applied at the quadriceps muscle bilaterally. Power output and muscle activation from both lower limbs were recorded throughout the tests. Increased performance in time-to-exhaustion tests was observed with the LLLT-135 J (∼22 s; P < .01), LLLT-270 J (∼13 s; P = .03), and LLLT-405 J (∼13 s; P = .02) compared to placebo (149 ± 23 s). Although LLLT-270 J and LLLT-405 J did not show significant differences in muscle activation compared with placebo, LLLT-135 J led to an increased high-frequency content compared with placebo in both limbs at the end of the exhaustion test (P ≤ .03). In conclusion, LLLT increased time to exhaustion in competitive cyclists, suggesting this intervention as a possible nonpharmacological ergogenic agent in cycling. Among the different dosages, LLLT-135 J seems to promote the best effects.
Zhou, Fei; Li, Zheng; Luo, Xuan; Wu, Tong; Jiang, Bin; Lu, Lei-Lei; Yao, Hong-Bin; Antonietti, Markus; Yu, Shu-Hong
2018-02-14
Lithium sulfur (Li-S) batteries are considered as promising energy storage systems for the next generation of batteries due to their high theoretical energy densities and low cost. Much effort has been made to improve the practical energy densities and cycling stability of Li-S batteries via diverse designs of materials nanostructure. However, achieving simultaneously good rate capabilities and stable cycling of Li-S batteries is still challenging. Herein, we propose a strategy to utilize a dual effect of metal carbide nanoparticles decorated on carbon nanofibers (MC NPs-CNFs) to realize high rate performance, low hysteresis, and long cycling stability of Li-S batteries in one system. The adsorption experiments of lithium polysulfides (LiPS) to MC NPs and corresponding theoretical calculations demonstrate that LiPS are likely to be adsorbed and diffused on the surface of MC NPs because of their moderate chemical bonding. MC NPs turn out to have also an electrocatalytic role and accelerate electrochemical redox reactions of LiPS, as proven by cyclic voltammetry analysis. The fabricated Li-S batteries based on the W 2 C NPs-CNFs hybrid electrodes display not only high specific capacity of 1200 mAh/g at 0.2C but also excellent rate performance and cycling stability, for example, a model setup can be operated at 1C for 500 cycles maintaining a final specific capacity of 605 mAh/g with a degradation rate as low as 0.06%/cycle.
Goodman, Joseph; Caravati, Kevin; Foote, Andrew; Nelson, Molly; Woods, Emily
2013-06-01
One of the methods proposed to improve access to clean drinking water is the mobile packaged water treatment system (MPWTS). The lack of published system performance comparisons combined with the diversity of technology available and intended operating conditions make it difficult for stakeholders to choose the system best suited for their application. MPWTS are often deployed in emergency situations, making selection of the appropriate system crucial to avoiding wasted resources and loss of life. Measurable critical-to-quality characteristics (CTQs) and a system selection tool for MPWTS were developed by utilizing relevant literature, including field studies, and implementing and comparing seven different MPWTS. The proposed System Life Cycle Evaluation (SLiCE) method uses these CTQs to evaluate the diversity in system performance and harmonize relevant performance with stakeholder preference via a selection tool. Agencies and field workers can use SLiCE results to inform and drive decision-making. The evaluation and selection tool also serves as a catalyst for communicating system performance, common design flaws, and stakeholder needs to system manufacturers. The SLiCE framework can be adopted into other emerging system technologies to communicate system performance over the life cycle of use.
NASA Astrophysics Data System (ADS)
Campanari, Stefano; Mastropasqua, Luca; Gazzani, Matteo; Chiesa, Paolo; Romano, Matteo C.
2016-09-01
An important advantage of solid oxide fuel cells (SOFC) as future systems for large scale power generation is the possibility of being efficiently integrated with processes for CO2 capture. Focusing on natural gas power generation, Part A of this work assessed the performances of advanced pressurised and atmospheric plant configurations (SOFC + GT and SOFC + ST, with fuel cell integration within a gas turbine or a steam turbine cycle) without CO2 separation. This Part B paper investigates such kind of power cycles when applied to CO2 capture, proposing two ultra-high efficiency plant configurations based on advanced intermediate-temperature SOFCs with internal reforming and low temperature CO2 separation process. The power plants are simulated at the 100 MW scale with a set of realistic assumptions about FC performances, main components and auxiliaries, and show the capability of exceeding 70% LHV efficiency with high CO2 capture (above 80%) and a low specific primary energy consumption for the CO2 avoided (1.1-2.4 MJ kg-1). Detailed results are presented in terms of energy and material balances, and a sensitivity analysis of plant performance is developed vs. FC voltage and fuel utilisation to investigate possible long-term improvements. Options for further improvement of the CO2 capture efficiency are also addressed.
National Combustion Code Parallel Performance Enhancements
NASA Technical Reports Server (NTRS)
Quealy, Angela; Benyo, Theresa (Technical Monitor)
2002-01-01
The National Combustion Code (NCC) is being developed by an industry-government team for the design and analysis of combustion systems. The unstructured grid, reacting flow code uses a distributed memory, message passing model for its parallel implementation. The focus of the present effort has been to improve the performance of the NCC code to meet combustor designer requirements for model accuracy and analysis turnaround time. Improving the performance of this code contributes significantly to the overall reduction in time and cost of the combustor design cycle. This report describes recent parallel processing modifications to NCC that have improved the parallel scalability of the code, enabling a two hour turnaround for a 1.3 million element fully reacting combustion simulation on an SGI Origin 2000.
A probability-based multi-cycle sorting method for 4D-MRI: A simulation study
Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing
2016-01-01
Purpose: To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Methods: Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients’ breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Results: Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. Conclusions: In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors’ preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management. PMID:27908178
Leader Development: The Importance of Communication, Trust, and Legacy
2014-06-13
Toyota Way were the spirit of challenge, kaizen (constantly improve performance), genchi genbutsu (philosophy of how leaders make decisions...the results will follow. Take responsibility for helping people advance through self-developing learning cycle. 3. Support Daily Kaizen : learn how
NASA Astrophysics Data System (ADS)
Jeong, Tae-Gyung; Chun, Jinyong; Cho, Byung-Won; Lee, Jinwoo; Kim, Yong-Tae
2017-02-01
The porous carbon matrix is widely recognized to be a promising sulfur reservoir to improve the cycle life by suppressing the polysulfide dissolution in lithium sulfur batteries (LSB). Herein, we synthesized mesocellular carbon foam (MSUF-C) with bimodal mesopore (4 and 30 nm) and large pore volume (1.72 cm2/g) using MSUF silica as a template and employed it as both the sulfur reservoir and the conductive agent in the sulfur cathode. Sulfur was uniformly infiltrated into MSUF-C pores by a chemical solution deposition method (MSUF-C/S CSD) and the amount of sulfur loading was achieved as high as 73% thanks to the large pore volume with the CSD approach. MSUF-C/S CSD showed a high capacity (889 mAh/g after 100 cycles at 0.2 C), an improved rate capability (879 mAh/g at 1C and 420 mAh/g at 2C), and a good capacity retention with a fade rate of 0.16% per cycle over 100 cycles.
Jeong, Tae-Gyung; Chun, Jinyong; Cho, Byung-Won; Lee, Jinwoo; Kim, Yong-Tae
2017-01-01
The porous carbon matrix is widely recognized to be a promising sulfur reservoir to improve the cycle life by suppressing the polysulfide dissolution in lithium sulfur batteries (LSB). Herein, we synthesized mesocellular carbon foam (MSUF-C) with bimodal mesopore (4 and 30 nm) and large pore volume (1.72 cm2/g) using MSUF silica as a template and employed it as both the sulfur reservoir and the conductive agent in the sulfur cathode. Sulfur was uniformly infiltrated into MSUF-C pores by a chemical solution deposition method (MSUF-C/S CSD) and the amount of sulfur loading was achieved as high as 73% thanks to the large pore volume with the CSD approach. MSUF-C/S CSD showed a high capacity (889 mAh/g after 100 cycles at 0.2 C), an improved rate capability (879 mAh/g at 1C and 420 mAh/g at 2C), and a good capacity retention with a fade rate of 0.16% per cycle over 100 cycles. PMID:28165041
NASA Astrophysics Data System (ADS)
Li, Jing-quan; Han, Chong; Jing, Mao-xiang; Yang, Hua; Shen, Xiang-qian; Qin, Shi-biao
2018-06-01
Low electronic and ionic conductivity for LiV3O8 cathode material could lead to poor cycling stability and rate capability, which are considered as the main restraint for its application in Li-ion battery. A novel flake-like LiV3O7.9 material modified by high ionic and electronic conductive Li0.3V2O5/C was fabricated via electrospinning and controlled thermal sintering processes. This oxygen-deficient LiV3O7.9/Li0.3V2O5-C composite electrode sintered at 500 °C exhibits improved rate and cycle stability. The electrode possesses a retention capacity of 151.9mAh/g after 500 cycles at 5C and 84.8mAh/g after 1000 cycles at 10C, respectively. The improvement of the electrochemical performance could be attributed to the synergistic effects of flake-like morphology, oxygen-deficiency and surface modification of Li0.3V2O5/C, which increase the ionic and electronic conductivity of LiV3O8.
Mixed Polyanion Glass Cathodes: Mixed Alkali Effect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kercher, A. K.; Chapel, A. S.; Kolopus, J. A.
2017-01-01
In lithium-ion batteries, mixed polyanion glass cathodes have demonstrated high capacities (200-500 mAh/g) by undergoing conversion and intercalation reactions. Mixed polyanion glasses typically have the same fundamental issues as other conversion cathodes, i.e.: large hysteresis, capacity fade, and 1st-cycle irreversible loss. A key advantage of glass cathodes is the ability to tailor their composition to optimize the desired physical properties and electrochemical performance. The strong dependence of glass physical properties (e.g., ionic diffusivity, electrical conductivity, and chemical durability) on the composition of alkali mixtures in a glass is well known and has been named the mixed alkali effect. The mixedmore » alkali effect on battery electrochemical properties is reported here for the first time. Depending on glass composition, the mixed alkali effect is shown to improve capacity retention during cycling (from 39% to 50% after 50 cycle test), to reduce the 1st-cycle irreversible loss (from 41% to 22%), and improve the high power (500 mA/g) capacity (from 50% to 67% of slow discharge capacity).« less
An On-Demand Emergency Packet Transmission Scheme for Wireless Body Area Networks.
Al Ameen, Moshaddique; Hong, Choong Seon
2015-12-04
The rapid developments of sensor devices that can actively monitor human activities have given rise to a new field called wireless body area network (BAN). A BAN can manage devices in, on and around the human body. Major requirements of such a network are energy efficiency, long lifetime, low delay, security, etc. Traffic in a BAN can be scheduled (normal) or event-driven (emergency). Traditional media access control (MAC) protocols use duty cycling to improve performance. A sleep-wake up cycle is employed to save energy. However, this mechanism lacks features to handle emergency traffic in a prompt and immediate manner. To deliver an emergency packet, a node has to wait until the receiver is awake. It also suffers from overheads, such as idle listening, overhearing and control packet handshakes. An external radio-triggered wake up mechanism is proposed to handle prompt communication. It can reduce the overheads and improve the performance through an on-demand scheme. In this work, we present a simple-to-implement on-demand packet transmission scheme by taking into considerations the requirements of a BAN. The major concern is handling the event-based emergency traffic. The performance analysis of the proposed scheme is presented. The results showed significant improvements in the overall performance of a BAN compared to state-of-the-art protocols in terms of energy consumption, delay and lifetime.
An On-Demand Emergency Packet Transmission Scheme for Wireless Body Area Networks
Al Ameen, Moshaddique; Hong, Choong Seon
2015-01-01
The rapid developments of sensor devices that can actively monitor human activities have given rise to a new field called wireless body area network (BAN). A BAN can manage devices in, on and around the human body. Major requirements of such a network are energy efficiency, long lifetime, low delay, security, etc. Traffic in a BAN can be scheduled (normal) or event-driven (emergency). Traditional media access control (MAC) protocols use duty cycling to improve performance. A sleep-wake up cycle is employed to save energy. However, this mechanism lacks features to handle emergency traffic in a prompt and immediate manner. To deliver an emergency packet, a node has to wait until the receiver is awake. It also suffers from overheads, such as idle listening, overhearing and control packet handshakes. An external radio-triggered wake up mechanism is proposed to handle prompt communication. It can reduce the overheads and improve the performance through an on-demand scheme. In this work, we present a simple-to-implement on-demand packet transmission scheme by taking into considerations the requirements of a BAN. The major concern is handling the event-based emergency traffic. The performance analysis of the proposed scheme is presented. The results showed significant improvements in the overall performance of a BAN compared to state-of-the-art protocols in terms of energy consumption, delay and lifetime. PMID:26690161
NASA Astrophysics Data System (ADS)
You, Jiangfeng; Xin, Ling; Yu, Xiao; Zhou, Xiang; Liu, Yong
2018-03-01
Homogeneous CaMoO4 microspheres with interesting nanopit morphology were prepared by a simple one-step hydrothermal method. These microspheres had a very promising alternative structure for application in Li-ion batteries (LIBs), because they combined the advantages of both the primary nanosized and secondary microsized structures. The nanopits distributed on CaMoO4 material can accommodate volume change, increase their contacting surface and wetting property with electrolyte, and improve wetting contact between CaMoO4 material and electrolyte, leading to enhanced cycling stability and electrochemical performance. Meanwhile, the robust microsphere structure can both prevent aggregation and provide high tap density. When used as an anode in LIBs, the electrodes delivered a high discharge capacity of 434 mAh/g after 50 charge-discharge cycles at a current density of 200 mA/g, showing good cycling performance.
Mesoporous Li1.2Mn0.54Ni0.13Co0.13O2 nanotubes for high-performance cathodes in Li-ion batteries
NASA Astrophysics Data System (ADS)
Ma, Dingtao; Li, Yongliang; Zhang, Peixin; Cooper, Adam J.; Abdelkader, Amr M.; Ren, Xiangzhong; Deng, Libo
2016-04-01
One-dimensional nanotubes constructed from interconnected Li1.2Mn0.54Ni0.13Co0.13O2 secondary particles of diameters measuring ca. 40 nm, were synthesized by a one-pot electrospinning method. Novel electrodes were constructed from (a) nanoparticles only, and (b) hollow nanofibres, and employed as cathodes in Li-ion batteries. The nanotube cathode exhibited impressive specific charge capacity, good cycling stability, and excellent rate capability. A discharge capacity of 140 mAh g-1 with capacity retention of 89% at 3 C was achieved after 300 cycles. The significant improvement of electrochemical performance is attributed to the high surface area of the nanotubes, well-guided charge transfer kinetics with short ionic diffusion pathways, and large effective contact area with the electrolyte during the cycling process.
Side-welded fast response sheathed thermocouple
Carr, K.R.
A method of fabricating the measuring junction of a grounded-junction sheathed thermocouple to obtain fast time response and good thermal cycling performance is provided. Slots are tooled or machined into the sheath wall at the measuring junction, the thermocouple wires are laser-welded into the slots. A thin metal closure cap is then laser-welded over the end of the sheath. Compared to a conventional grounded-junction thermocouple, the response time is 4 to 5 times faster and the thermal shock and cycling capabilities are substantially improved.
Side-welded fast response sheathed thermocouple
Carr, Kenneth R.
1981-01-01
A method of fabricating the measuring junction of a grounded-junction sheathed thermocouple to obtain fast time response and good thermal cycling performance is provided. Slots are tooled or machined into the sheath wall at the measuring junction, the thermocouple wires are laser-welded into the slots. A thin metal closure cap is then laser-welded over the end of the sheath. Compared to a conventional grounded-junction thermocouple, the response time is 4-5 times faster and the thermal shock and cycling capabilities are substantially improved.
Yabe, Shiori; Hara, Takashi; Ueno, Mariko; Enoki, Hiroyuki; Kimura, Tatsuro; Nishimura, Satoru; Yasui, Yasuo; Ohsawa, Ryo; Iwata, Hiroyoshi
2018-01-01
To evaluate the potential of genomic selection (GS), a selection experiment with GS and phenotypic selection (PS) was performed in an allogamous crop, common buckwheat ( Fagopyrum esculentum Moench). To indirectly select for seed yield per unit area, which cannot be measured on a single-plant basis, a selection index was constructed from seven agro-morphological traits measurable on a single plant basis. Over 3 years, we performed two GS and one PS cycles per year for improvement in the selection index. In GS, a prediction model was updated every year on the basis of genotypes of 14,598-50,000 markers and phenotypes. Plants grown from seeds derived from a series of generations of GS and PS populations were evaluated for the traits in the selection index and other yield-related traits. GS resulted in a 20.9% increase and PS in a 15.0% increase in the selection index in comparison with the initial population. Although the level of linkage disequilibrium in the breeding population was low, the target trait was improved with GS. Traits with higher weights in the selection index were improved more than those with lower weights, especially when prediction accuracy was high. No trait changed in an unintended direction in either GS or PS. The accuracy of genomic prediction models built in the first cycle decreased in the later cycles because the genetic bottleneck through the selection cycles changed linkage disequilibrium patterns in the breeding population. The present study emphasizes the importance of updating models in GS and demonstrates the potential of GS in mass selection of allogamous crop species, and provided a pilot example of successful application of GS to plant breeding.
Yabe, Shiori; Hara, Takashi; Ueno, Mariko; Enoki, Hiroyuki; Kimura, Tatsuro; Nishimura, Satoru; Yasui, Yasuo; Ohsawa, Ryo; Iwata, Hiroyoshi
2018-01-01
To evaluate the potential of genomic selection (GS), a selection experiment with GS and phenotypic selection (PS) was performed in an allogamous crop, common buckwheat (Fagopyrum esculentum Moench). To indirectly select for seed yield per unit area, which cannot be measured on a single-plant basis, a selection index was constructed from seven agro-morphological traits measurable on a single plant basis. Over 3 years, we performed two GS and one PS cycles per year for improvement in the selection index. In GS, a prediction model was updated every year on the basis of genotypes of 14,598–50,000 markers and phenotypes. Plants grown from seeds derived from a series of generations of GS and PS populations were evaluated for the traits in the selection index and other yield-related traits. GS resulted in a 20.9% increase and PS in a 15.0% increase in the selection index in comparison with the initial population. Although the level of linkage disequilibrium in the breeding population was low, the target trait was improved with GS. Traits with higher weights in the selection index were improved more than those with lower weights, especially when prediction accuracy was high. No trait changed in an unintended direction in either GS or PS. The accuracy of genomic prediction models built in the first cycle decreased in the later cycles because the genetic bottleneck through the selection cycles changed linkage disequilibrium patterns in the breeding population. The present study emphasizes the importance of updating models in GS and demonstrates the potential of GS in mass selection of allogamous crop species, and provided a pilot example of successful application of GS to plant breeding. PMID:29619035
High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less
High-reliability gas-turbine combined-cycle development program: Phase II. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less
Performance of Poly(lactic acid) Surface Modified Films for Food Packaging Application
Dalla Rosa, Marco; Iordanskii, Alexey L.
2017-01-01
Five Poly(lactic acid) (PLA) film samples were analyzed to study the gas barrier behavior, thermal stability and mechanical performance for food packaging application. O2, CO2, N2, N2O, and C2H4 pure gases; Air; and Modified Atmosphere (MA, 79% N2O/21% O2) were used to analyze the influence of the chemical structure, storage temperature and crystalline phase on the gas barrier behavior. The kinetic of the permeation process was investigated at different temperatures, ranging from 5 °C to 40 °C. Annealing thermal treatment on the samples led to the crystalline percentage, influencing especially the gas solubility process. Thermal properties such as Tg and χc, and mechanical properties such as tensile strength and modulus were remarkably improved with surface PLA modification. A more pronounced reinforcing effect was noted in the case of metallization, as well as improved gas barrier performance. Tensile testing and tensile cycling tests confirmed the rigidity of the films, with about a 20% loss of elasticity after 25 cycles loading. PMID:28773210
Vázquez-Galván, Javier; Flox, Cristina; Fàbrega, Cristian; Ventosa, Edgar; Parra, Andres; Andreu, Teresa; Morante, Joan Ramón
2017-05-09
Hydrogen-treated TiO 2 as an electrocatalyst has shown to boost the capacity of high-performance all-vanadium redox flow batteries (VRFBs) as a simple and eco-friendly strategy. The graphite felt-based GF@TiO 2 :H electrode is able to inhibit the hydrogen evolution reaction (HER), which is a critical barrier for operating at high rate for long-term cycling in VRFBs. Significant improvements in charge/discharge and electron-transfer processes for the V 3+ /V 2+ reaction on the surface of reduced TiO 2 were achieved as a consequence of the formation of oxygen functional groups and oxygen vacancies in the lattice structure. Key performance indicators of VRFB have been improved, such as high capability rates and electrolyte-utilization ratios (82 % at 200 mA cm -2 ). Additionally, high coulombic efficiencies (ca. 100 % up to the 96th cycle, afterwards >97 %) were obtained, demonstrating the feasibility of achieving long-term stability. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ingwersen, Wesley W.
Life cycle assessment (LCA) is an internationally standardized framework for assessing the environmental impacts of products that is rapidly evolving to improve understanding and quantification of how complex product systems depend upon and affect the environment. This dissertation contributes to that evolution through the development of new methods for measuring impacts, estimating the uncertainty of impacts, and measuring ranges of environmental performance, with a focus on product systems in non-OECD countries that have not been well characterized. The integration of a measure of total energy use, emergy, is demonstrated in an LCA of gold from the Yanacocha mine in Peru in the second chapter. A model for estimating the accuracy of emergy results is proposed in the following chapter. The fourth chapter presents a template for LCA-based quantification of the range of environmental performance for tropical agricultural products using the example of fresh pineapple production for export in Costa Rica that can be used to create product labels with environmental information. The final chapter synthesizes how each methodological contribution will together improve the science of measuring product environmental performance.
Lithium-Ion Batteries for Aerospace Applications
NASA Technical Reports Server (NTRS)
Surampudi, S.; Halpert, G.; Marsh, R. A.; James, R.
1999-01-01
This presentation reviews: (1) the goals and objectives, (2) the NASA and Airforce requirements, (3) the potential near term missions, (4) management approach, (5) the technical approach and (6) the program road map. The objectives of the program include: (1) develop high specific energy and long life lithium ion cells and smart batteries for aerospace and defense applications, (2) establish domestic production sources, and to demonstrate technological readiness for various missions. The management approach is to encourage the teaming of universities, R&D organizations, and battery manufacturing companies, to build on existing commercial and government technology, and to develop two sources for manufacturing cells and batteries. The technological approach includes: (1) develop advanced electrode materials and electrolytes to achieve improved low temperature performance and long cycle life, (2) optimize cell design to improve specific energy, cycle life and safety, (3) establish manufacturing processes to ensure predictable performance, (4) establish manufacturing processes to ensure predictable performance, (5) develop aerospace lithium ion cells in various AH sizes and voltages, (6) develop electronics for smart battery management, (7) develop a performance database required for various applications, and (8) demonstrate technology readiness for the various missions. Charts which review the requirements for the Li-ion battery development program are presented.
Variable-cycle engines for supersonic cruising aircraft
NASA Technical Reports Server (NTRS)
Willis, E. A.; Welliver, A. D.
1976-01-01
The paper reviews the evolution and current status of selected recent variable-cycle engine (VCE) studies and describes how the results are influenced by airplane requirements. The engine/airplane studies are intended to identify promising VCE concepts, simplify their designs and identify the potential benefits in terms of aircraft performance. This includes range, noise, emissions, and the time and effort it may require to ensure technical readiness of sufficient depth to satisfy reasonable economic, performance, and environmental constraints. A brief overview of closely-related, on-going technology programs in acoustics and exhaust emissions is presented. It is shown that realistic technology advancements in critical areas combined with well matched aircraft and selected VCE concepts can lead to significantly improved economic and environmental performance relative to first-generation SST predictions.
Ji, Liwen; Zhou, Weidong; Chabot, Victor; Yu, Aiping; Xiao, Xingcheng
2015-11-11
Reduced graphene oxides loaded with tin-antimony alloy (RGO-SnSb) nanocomposites were synthesized through a hydrothermal reaction and the subsequent thermal reduction treatments. Transmission electron microscope images confirm that SnSb nanoparticles with an average size of about 20-30 nm are uniformly dispersed on the RGO surfaces. When they were used as anodes for rechargeable sodium (Na)-ion batteries, these as-synthesized RGO-SnSb nanocomposite anodes delivered a high initial reversible capacity of 407 mAh g(-1), stable cyclic retention for more than 80 cycles and excellent cycle stability at ultra high charge/discharge rates up to 30C. The significantly improved performance of the synthesized RGO-SnSb nanocomposites as Na-ion battery anodes can be attributed to the synergetic effects of RGO-based flexible framework and the nanoscale dimension of the SnSb alloy particles (<30 nm). Nanosized intermetallic SnSb compounds can exhibit improved structural stability and conductivity during charge and discharge reactions compared to the corresponding individuals (Sn and Sb particles). In the meantime, RGO sheets can tightly anchor SnSb alloy particles on the surfaces, which can not only effectively suppress the agglomeration of SnSb particles but also maintain excellent electronic conduction. Furthermore, the mechanical flexibility of the RGO phase can accommodate the volume expansion and contraction of SnSb particles during the prolonged cycling, therefore, improve the electrode integrity mechanically and electronically. All of these contribute to the electrochemical performance improvements of the RGO-SnSb nanocomposite-based electrodes in rechargeable Na-ion batteries.
Efficiency improvements of offline metrology job creation
NASA Astrophysics Data System (ADS)
Zuniga, Victor J.; Carlson, Alan; Podlesny, John C.; Knutrud, Paul C.
1999-06-01
Progress of the first lot of a new design through the production line is watched very closely. All performance metrics, cycle-time, in-line measurement results and final electrical performance are critical. Rapid movement of this lot through the line has serious time-to-market implications. Having this material waiting at a metrology operation for an engineer to create a measurement job plan wastes valuable turnaround time. Further, efficient use of a metrology system is compromised by the time required to create and maintain these measurement job plans. Thus, having a method to develop metrology job plans prior to the actual running of the material through the manufacture area can significantly improve both cycle time and overall equipment efficiency. Motorola and Schlumberger have worked together to develop and test such a system. The Remote Job Generator (RJG) created job plans for new device sin a manufacturing process from an NT host or workstation, offline. This increases available system tim effort making production measurements, decreases turnaround time on job plan creation and editing, and improves consistency across job plans. Most importantly this allows job plans for new devices to be available before the first wafers of the device arrive at the tool for measurement. The software also includes a database manager which allows updates of existing job plans to incorporate measurement changes required by process changes or measurement optimization. This paper will review the result of productivity enhancements through the increased metrology utilization and decreased cycle time associated with the use of RJG. Finally, improvements in process control through better control of Job Plans across different devices and layers will be discussed.
Parallel methodology to capture cyclic variability in motored engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ameen, Muhsin M.; Yang, Xiaofeng; Kuo, Tang-Wei
2016-07-28
Numerical prediction of of cycle-to-cycle variability (CCV) in SI engines is extremely challenging for two key reasons: (i) high-fidelity methods such as large eddy simulation (LES) are require to accurately capture the in-cylinder turbulent flowfield, and (ii) CCV is experienced over long timescales and hence the simulations need to be performed for hundreds of consecutive cycles. In this study, a new methodology is proposed to dissociate this long time-scale problem into several shorter time-scale problems, which can considerably reduce the computational time without sacrificing the fidelity of the simulations. The strategy is to perform multiple single-cycle simulations in parallel bymore » effectively perturbing the simulation parameters such as the initial and boundary conditions. It is shown that by perturbing the initial velocity field effectively based on the intensity of the in-cylinder turbulence, the mean and variance of the in-cylinder flowfield is captured reasonably well. Adding perturbations in the initial pressure field and the boundary pressure improves the predictions. It is shown that this new approach is able to give accurate predictions of the flowfield statistics in less than one-tenth of time required for the conventional approach of simulating consecutive engine cycles.« less
Zhao, Hui; Wei, Yang; Qiao, Ruimin; Zhu, Chenhui; Zheng, Ziyan; Ling, Min; Jia, Zhe; Bai, Ying; Fu, Yanbao; Lei, Jinglei; Song, Xiangyun; Battaglia, Vincent S; Yang, Wanli; Messersmith, Phillip B; Liu, Gao
2015-12-09
High-tap-density silicon nanomaterials are highly desirable as anodes for lithium ion batteries, due to their small surface area and minimum first-cycle loss. However, this material poses formidable challenges to polymeric binder design. Binders adhere on to the small surface area to sustain the drastic volume changes during cycling; also the low porosities and small pore size resulting from this material are detrimental to lithium ion transport. This study introduces a new binder, poly(1-pyrenemethyl methacrylate-co-methacrylic acid) (PPyMAA), for a high-tap-density nanosilicon electrode cycled in a stable manner with a first cycle efficiency of 82%-a value that is further improved to 87% when combined with graphite material. Incorporating the MAA acid functionalities does not change the lowest unoccupied molecular orbital (LUMO) features or lower the adhesion performance of the PPy homopolymer. Our single-molecule force microscopy measurement of PPyMAA reveals similar adhesion strength between polymer binder and anode surface when compared with conventional polymer such as homopolyacrylic acid (PAA), while being electronically conductive. The combined conductivity and adhesion afforded by the MAA and pyrene copolymer results in good cycling performance for the high-tap-density Si electrode.
Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren
2015-10-28
High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (∼1470 F g(-1) at 5 mV s(-1)) and excellent cycling stability with ∼98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg(-1)), a high power density (27.5 kW kg(-1)) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.
Zander, Alexis; Passmore, Erin; Mason, Chloe; Rissel, Chris
2013-01-01
Cycling can be an enjoyable way to meet physical activity recommendations and is suitable for older people; however cycling participation by older Australians is low. This qualitative study explored motivators, enablers, and barriers to cycling among older people through an age-targeted cycling promotion program. Seventeen adults who aged 50-75 years participated in a 12-week cycling promotion program which included a cycling skills course, mentor, and resource pack. Semistructured interviews at the beginning and end of the program explored motivators, enablers, and barriers to cycling. Fitness and recreation were the primary motivators for cycling. The biggest barrier was fear of cars and traffic, and the cycling skills course was the most important enabler for improving participants' confidence. Reported outcomes from cycling included improved quality of life (better mental health, social benefit, and empowerment) and improved physical health. A simple cycling program increased cycling participation among older people. This work confirms the importance of improving confidence in this age group through a skills course, mentors, and maps and highlights additional strategies for promoting cycling, such as ongoing improvement to infrastructure and advertising.
Passmore, Erin; Mason, Chloe; Rissel, Chris
2013-01-01
Introduction. Cycling can be an enjoyable way to meet physical activity recommendations and is suitable for older people; however cycling participation by older Australians is low. This qualitative study explored motivators, enablers, and barriers to cycling among older people through an age-targeted cycling promotion program. Methods. Seventeen adults who aged 50–75 years participated in a 12-week cycling promotion program which included a cycling skills course, mentor, and resource pack. Semistructured interviews at the beginning and end of the program explored motivators, enablers, and barriers to cycling. Results. Fitness and recreation were the primary motivators for cycling. The biggest barrier was fear of cars and traffic, and the cycling skills course was the most important enabler for improving participants' confidence. Reported outcomes from cycling included improved quality of life (better mental health, social benefit, and empowerment) and improved physical health. Conclusions. A simple cycling program increased cycling participation among older people. This work confirms the importance of improving confidence in this age group through a skills course, mentors, and maps and highlights additional strategies for promoting cycling, such as ongoing improvement to infrastructure and advertising. PMID:23864869
Reducing Communication in Algebraic Multigrid Using Additive Variants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vassilevski, Panayot S.; Yang, Ulrike Meier
Algebraic multigrid (AMG) has proven to be an effective scalable solver on many high performance computers. However, its increasing communication complexity on coarser levels has shown to seriously impact its performance on computers with high communication cost. Moreover, additive AMG variants provide not only increased parallelism as well as decreased numbers of messages per cycle but also generally exhibit slower convergence. Here we present various new additive variants with convergence rates that are significantly improved compared to the classical additive algebraic multigrid method and investigate their potential for decreased communication, and improved communication-computation overlap, features that are essential for goodmore » performance on future exascale architectures.« less
Reducing Communication in Algebraic Multigrid Using Additive Variants
Vassilevski, Panayot S.; Yang, Ulrike Meier
2014-02-12
Algebraic multigrid (AMG) has proven to be an effective scalable solver on many high performance computers. However, its increasing communication complexity on coarser levels has shown to seriously impact its performance on computers with high communication cost. Moreover, additive AMG variants provide not only increased parallelism as well as decreased numbers of messages per cycle but also generally exhibit slower convergence. Here we present various new additive variants with convergence rates that are significantly improved compared to the classical additive algebraic multigrid method and investigate their potential for decreased communication, and improved communication-computation overlap, features that are essential for goodmore » performance on future exascale architectures.« less
Method and apparatus for improving the performance of a steam driven power system by steam mixing
Tsiklauri, Georgi V.; Durst, Bruce M.; Prichard, Andrew W.; Reid, Bruce D.; Burritt, James
1998-01-01
A method and apparatus for improving the efficiency and performance of a steam driven power plant wherein addition of steam handling equipment to an existing plant results in a surprising increase in plant performance. For Example, a gas turbine electrical generation system with heat recovery boiler may be installed along with a micro-jet high pressure and a low pressure mixer superheater. Depending upon plant characteristics, the existing moisture separator reheater (MSR) can be either augmented or done away with. The instant invention enables a reduction in T.sub.hot without a derating of the reactor unit, and improves efficiency of the plant's electrical conversion cycle. Coupled with this advantage is a possible extension of the plant's fuel cycle length due to an increased electrical conversion efficiency. The reduction in T.sub.hot further allows for a surprising extension of steam generator life. An additional advantage is the reduction in erosion/corrosion of secondary system components including turbine blades and diaphragms. The gas turbine generator used in the instant invention can also replace or augment existing peak or emergency power needs. Another benefit of the instant invention is the extension of plant life and the reduction of downtime due to refueling.
NASA Astrophysics Data System (ADS)
Sam, Ashish Alex; Ghosh, Parthasarathi
2017-03-01
Turboexpander constitutes one of the vital components of Claude cycle based helium refrigerators and liquefiers that are gaining increasing technological importance. These turboexpanders which are of radial inflow in configuration are generally high-speed micro turbines, due to the low molecular weight and density of helium. Any improvement in efficiency of these machines requires a detailed understanding of the flow field. Computational Fluid Dynamics analysis (CFD) has emerged as a necessary tool for the determination of the flow fields in cryogenic turboexpanders, which is often not possible through experiments. In the present work three-dimensional transient flow analysis of a cryogenic turboexpander for helium refrigeration and liquefaction cycles were performed using Ansys CFX®, to understand the flow field of a high-speed helium turboexpander, which in turn will help in taking appropriate decisions regarding modifications of established design methodology for improved efficiency of these machines. The turboexpander is designed based on Balje's nsds diagram and the inverse design blade profile generation formalism prescribed by Hasselgruber and Balje. The analyses include the study of several losses, their origins, the increase in entropy due to these losses, quantification of losses and the effects of various geometrical parameters on these losses. Through the flow field analysis it was observed that in the nozzle, flow separation at the nozzle blade suction side and trailing edge vortices resulted in loss generation, which calls for better nozzle blade profile. The turbine wheel flow field analysis revealed that the significant geometrical parameters of the turbine wheel blade like blade inlet angle, blade profile, tip clearance height and trailing edge thickness need to be optimised for improved performance of the turboexpander. The detailed flow field analysis in this paper can be used to improve the mean line design methodology for turboexpanders used in helium refrigeration and liquefaction cycles.
(abstract) Effect of Electrolyte Composition on Carbon Electrode Performance
NASA Technical Reports Server (NTRS)
Huang, C-K.; Surampudi, S.; Shen, D. H.; Halpert, G.
1993-01-01
Rechargeable lithium cells containing lithium foil anodes are reported to have limited cycle life (at 100% DOD) performance and safety problems. These limitations are understood to be due to the high reactivity of elemental Li with the electrolyte and the formation of high surface area Li during cycling. To mitigate these problems, several lithium alloys and lithium intercalation compounds are being investigated as alternate lithium anode materials. Li(sub x)C has been identified as a promising lithium anode material due to its low equivalent weight, low voltage vs. Li, and improved stability towards various electrolytes. In this paper, we report the results of our studies on the electrolyte evaluation for the Li(sub x)C anode.
An all-solid-state lithium/polyaniline rechargeable cell
NASA Astrophysics Data System (ADS)
Li, Changzhi; Peng, Xinsheng; Zhang, Borong; Wang, Baochen
1992-07-01
The performance of an all-solid-state cell having a lithium negative electrode, a modified polyethylene oxide (PEO)-epoxy resin (ER) electrolyte, and a polyaniline (PAn) positive electrode has been studied using cyclic voltammetry, charge/discharge cycling, and polarization curves at various temperatures. The redox reaction of the PAn electrode at the PAn/modified PEO-ER interface exhibits good reversibility. At 50-80 C, the Li/PEO-ER-LiClO4/PAn cell shows more than 40 charge/discharge cycles, 90 percent charge/discharge efficiency, and 54 W h kg discharge energy density (on PAn weight basis) at 50 micro-A between 2 and 4 V. The polarization performance of the battery improves steadily with increase in temperature.
A Module Experimental Process System Development Unit (MEPSDU)
NASA Technical Reports Server (NTRS)
1981-01-01
Subsequent to the design review, a series of tests was conducted on simulated modules to demonstrate that all environmental specifications (wind loading, hailstone impact, thermal cycling, and humidity cycling) are satisfied by the design. All tests, except hailstone impact, were successfully completed. The assembly sequence was simplified by virtue of eliminating the frame components and assembly steps. Performance was improved by reducing the module edge border required to accommodate the frame of the preliminary design module. An ultrasonic rolling spot bonding technique was selected for use in the machine to perform the aluminum interconnect to cell metallization electrical joints required in the MEPSDU module configuration. This selection was based on extensive experimental tests and economic analyses.
Development of an Open Rotor Cycle Model in NPSS Using a Multi-Design Point Approach
NASA Technical Reports Server (NTRS)
Hendricks, Eric S.
2011-01-01
NASA's Environmentally Responsible Aviation Project and Subsonic Fixed Wing Project are focused on developing concepts and technologies which may enable dramatic reductions to the environmental impact of future generation subsonic aircraft (Refs. 1 and 2). The open rotor concept (also referred to as the Unducted Fan or advanced turboprop) may allow the achievement of this objective by reducing engine emissions and fuel consumption. To evaluate its potential impact, an open rotor cycle modeling capability is needed. This paper presents the initial development of an open rotor cycle model in the Numerical Propulsion System Simulation (NPSS) computer program which can then be used to evaluate the potential benefit of this engine. The development of this open rotor model necessitated addressing two modeling needs within NPSS. First, a method for evaluating the performance of counter-rotating propellers was needed. Therefore, a new counter-rotating propeller NPSS component was created. This component uses propeller performance maps developed from historic counter-rotating propeller experiments to determine the thrust delivered and power required. Second, several methods for modeling a counter-rotating power turbine within NPSS were explored. These techniques used several combinations of turbine components within NPSS to provide the necessary power to the propellers. Ultimately, a single turbine component with a conventional turbine map was selected. Using these modeling enhancements, an open rotor cycle model was developed in NPSS using a multi-design point approach. The multi-design point (MDP) approach improves the engine cycle analysis process by making it easier to properly size the engine to meet a variety of thrust targets throughout the flight envelope. A number of design points are considered including an aerodynamic design point, sea-level static, takeoff and top of climb. The development of this MDP model was also enabled by the selection of a simple power management scheme which schedules propeller blade angles with the freestream Mach number. Finally, sample open rotor performance results and areas for further model improvements are presented.
NASA Astrophysics Data System (ADS)
Sánchez, D.; Muñoz de Escalona, J. M.; Monje, B.; Chacartegui, R.; Sánchez, T.
This article presents a novel proposal for complex hybrid systems comprising high temperature fuel cells and thermal engines. In this case, the system is composed by a molten carbonate fuel cell with cascaded hot air turbine and Organic Rankine Cycle (ORC), a layout that is based on subsequent waste heat recovery for additional power production. The work will credit that it is possible to achieve 60% efficiency even if the fuel cell operates at atmospheric pressure. The first part of the analysis focuses on selecting the working fluid of the Organic Rankine Cycle. After a thermodynamic optimisation, toluene turns out to be the most efficient fluid in terms of cycle performance. However, it is also detected that the performance of the heat recovery vapour generator is equally important, what makes R245fa be the most interesting fluid due to its balanced thermal and HRVG efficiencies that yield the highest global bottoming cycle efficiency. When this fluid is employed in the compound system, conservative operating conditions permit achieving 60% global system efficiency, therefore accomplishing the initial objective set up in the work. A simultaneous optimisation of gas turbine (pressure ratio) and ORC (live vapour pressure) is then presented, to check if the previous results are improved or if the fluid of choice must be replaced. Eventually, even if system performance improves for some fluids, it is concluded that (i) R245fa is the most efficient fluid and (ii) the operating conditions considered in the previous analysis are still valid. The work concludes with an assessment about safety-related aspects of using hydrocarbons in the system. Flammability is studied, showing that R245fa is the most interesting fluid also in this regard due to its inert behaviour, as opposed to the other fluids under consideration all of which are highly flammable.
Gao, Guoxin; Wu, Hao Bin; Ding, Shujiang; Liu, Li-Min; Lou, Xiong Wen David
2015-02-18
A high-performance electrode for supercapacitors is designed and synthesized by growing electroactive NiCo2 O4 nanosheets on conductive Ni nanofoam. Because of the structural advantages, the as-prepared Ni@NiCo2 O4 hybrid nanostructure exhibits significantly improved electrochemical performance with high capacitance, excellent rate capability, and good cycling stability. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Optimization design and performance analysis of a miniature stirling engine
NASA Astrophysics Data System (ADS)
You, Zhanping; Yang, Bo; Pan, Lisheng; Hao, Changsheng
2017-10-01
Under given operation conditions, a stirling engine of 2 kW is designed which takes hydrogen as working medium. Through establishment of adiabatic model, the ways are achieved about performance improving. The ways are raising the temperature of hot terminal, lowering the temperature of cold end, increasing the average cycle pressure, speeding up the speed, phase angle being 90°, stroke volume ratio approximating to 1 and increasing the performance of regenerator.
NASA Astrophysics Data System (ADS)
Chen, Yaping; Liu, Borui; Liu, Qi; Wang, Jun; Li, Zhanshuang; Jing, Xiaoyan; Liu, Lianhe
2015-09-01
Flexible all-solid-state supercapacitors have offered promising applications as novel energy storage devices based on their merits, such as small size, low cost, light weight and high wearability for high-performance portable electronics. However, one major challenge to make flexible all-solid-state supercapacitors depends on the improvement of electrode materials with higher electrical conductivity properties and longer cycling stability. In this article, we put forward a simple strategy to in situ synthesize 1D CoMoO4 nanowires (NWs), using highly conductive CC and an electrically conductive PPy wrapping layer on CoMoO4 NW arrays for high performance electrode materials. The results show that the CoMoO4/PPy hybrid NW electrode exhibits a high areal specific capacitance of ca. 1.34 F cm-2 at a current density of 2 mA cm-2, which is remarkably better than the corresponding values for a pure CoMoO4 NW electrode of 0.7 F cm-2. An excellent cycling performance of nanocomposites of up to 95.2% (ca. 1.12 F cm-2) is achieved after 2000 cycles compared to pristine CoMoO4 NWs. In addition, we fabricate flexible all-solid-state ASC which can be cycled reversibly in the voltage range of 0-1.7 V, and exhibits a maximum energy density of 104.7 W h kg-1 (3.522 mW h cm-3), demonstrating great potential for practical applications in flexible energy storage electronics.Flexible all-solid-state supercapacitors have offered promising applications as novel energy storage devices based on their merits, such as small size, low cost, light weight and high wearability for high-performance portable electronics. However, one major challenge to make flexible all-solid-state supercapacitors depends on the improvement of electrode materials with higher electrical conductivity properties and longer cycling stability. In this article, we put forward a simple strategy to in situ synthesize 1D CoMoO4 nanowires (NWs), using highly conductive CC and an electrically conductive PPy wrapping layer on CoMoO4 NW arrays for high performance electrode materials. The results show that the CoMoO4/PPy hybrid NW electrode exhibits a high areal specific capacitance of ca. 1.34 F cm-2 at a current density of 2 mA cm-2, which is remarkably better than the corresponding values for a pure CoMoO4 NW electrode of 0.7 F cm-2. An excellent cycling performance of nanocomposites of up to 95.2% (ca. 1.12 F cm-2) is achieved after 2000 cycles compared to pristine CoMoO4 NWs. In addition, we fabricate flexible all-solid-state ASC which can be cycled reversibly in the voltage range of 0-1.7 V, and exhibits a maximum energy density of 104.7 W h kg-1 (3.522 mW h cm-3), demonstrating great potential for practical applications in flexible energy storage electronics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr02961a
Metallic positive expulsion diaphragms
NASA Technical Reports Server (NTRS)
Gleich, D.
1972-01-01
High-cycle life ring-reinforced hemispherical type positive expulsion diaphragm performance was demonstrated by room temperature fluid expulsion tests of 13" diameter, 8 mil thick stainless steel configurations. A maximum of eleven (11) leak-free, fluid expulsions were achieved by a 25 deg cone angle diaphragm hoop-reinforced with .110-inch cross-sectional diameter wires. This represents a 70% improvement in diaphragm reversal cycle life compared to results previously obtained. The reversal tests confirmed analytic predictions for diaphragm cycle life increases due to increasing values of diaphragm cone angle, radius to thickness ratio and material strain to necking capacity. Practical fabrication techniques were demonstrated for forming close-tolerance, thin corrugated shells and for obtaining closely controlled reinforcing ring stiffness required to maximize diaphragm cycle life. A non-destructive inspection technique for monitoring large local shell bending strains was developed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breedveld, Sebastiaan; Storchi, Pascal R. M.; Voet, Peter W. J.
2012-02-15
Purpose: To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. Methods: A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions betweenmore » patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al.[Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. Results: Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. Conclusions: Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.« less
Practice-tailored facilitation to improve pediatric preventive care delivery: a randomized trial.
Meropol, Sharon B; Schiltz, Nicholas K; Sattar, Abdus; Stange, Kurt C; Nevar, Ann H; Davey, Christina; Ferretti, Gerald A; Howell, Diana E; Strosaker, Robyn; Vavrek, Pamela; Bader, Samantha; Ruhe, Mary C; Cuttler, Leona
2014-06-01
Evolving primary care models require methods to help practices achieve quality standards. This study assessed the effectiveness of a Practice-Tailored Facilitation Intervention for improving delivery of 3 pediatric preventive services. In this cluster-randomized trial, a practice facilitator implemented practice-tailored rapid-cycle feedback/change strategies for improving obesity screening/counseling, lead screening, and dental fluoride varnish application. Thirty practices were randomized to Early or Late Intervention, and outcomes assessed for 16 419 well-child visits. A multidisciplinary team characterized facilitation processes by using comparative case study methods. Baseline performance was as follows: for Obesity: 3.5% successful performance in Early and 6.3% in Late practices, P = .74; Lead: 62.2% and 77.8% success, respectively, P = .11; and Fluoride: <0.1% success for all practices. Four months after randomization, performance rose in Early practices, to 82.8% for Obesity, 86.3% for Lead, and 89.1% for Fluoride, all P < .001 for improvement compared with Late practices' control time. During the full 6-month intervention, care improved versus baseline in all practices, for Obesity for Early practices to 86.5%, and for Late practices 88.9%; for Lead for Early practices to 87.5% and Late practices 94.5%; and for Fluoride, for Early practices to 78.9% and Late practices 81.9%, all P < .001 compared with baseline. Improvements were sustained 2 months after intervention. Successful facilitation involved multidisciplinary support, rapid-cycle problem solving feedback, and ongoing relationship-building, allowing individualizing facilitation approach and intensity based on 3 levels of practice need. Practice-tailored Facilitation Intervention can lead to substantial, simultaneous, and sustained improvements in 3 domains, and holds promise as a broad-based method to advance pediatric preventive care. Copyright © 2014 by the American Academy of Pediatrics.
Practice-Tailored Facilitation to Improve Pediatric Preventive Care Delivery: A Randomized Trial
Schiltz, Nicholas K.; Sattar, Abdus; Stange, Kurt C.; Nevar, Ann H.; Davey, Christina; Ferretti, Gerald A.; Howell, Diana E.; Strosaker, Robyn; Vavrek, Pamela; Bader, Samantha; Ruhe, Mary C.; Cuttler, Leona
2014-01-01
OBJECTIVE: Evolving primary care models require methods to help practices achieve quality standards. This study assessed the effectiveness of a Practice-Tailored Facilitation Intervention for improving delivery of 3 pediatric preventive services. METHODS: In this cluster-randomized trial, a practice facilitator implemented practice-tailored rapid-cycle feedback/change strategies for improving obesity screening/counseling, lead screening, and dental fluoride varnish application. Thirty practices were randomized to Early or Late Intervention, and outcomes assessed for 16 419 well-child visits. A multidisciplinary team characterized facilitation processes by using comparative case study methods. RESULTS: Baseline performance was as follows: for Obesity: 3.5% successful performance in Early and 6.3% in Late practices, P = .74; Lead: 62.2% and 77.8% success, respectively, P = .11; and Fluoride: <0.1% success for all practices. Four months after randomization, performance rose in Early practices, to 82.8% for Obesity, 86.3% for Lead, and 89.1% for Fluoride, all P < .001 for improvement compared with Late practices’ control time. During the full 6-month intervention, care improved versus baseline in all practices, for Obesity for Early practices to 86.5%, and for Late practices 88.9%; for Lead for Early practices to 87.5% and Late practices 94.5%; and for Fluoride, for Early practices to 78.9% and Late practices 81.9%, all P < .001 compared with baseline. Improvements were sustained 2 months after intervention. Successful facilitation involved multidisciplinary support, rapid-cycle problem solving feedback, and ongoing relationship-building, allowing individualizing facilitation approach and intensity based on 3 levels of practice need. CONCLUSIONS: Practice-tailored Facilitation Intervention can lead to substantial, simultaneous, and sustained improvements in 3 domains, and holds promise as a broad-based method to advance pediatric preventive care. PMID:24799539
Crewther, Blair T; Lowe, Tim; Weatherby, Robert P; Gill, Nicholas
2009-04-01
This study examined the effect of cycle sprints as a potentiating stimulus for power and strength adaptation in semi-elite athletes. Eighteen rugby players were assigned into training groups that completed either a 40-s cycle sprint (T(SPRINT)) or rested (T(CONTROL)) before each workout (n = 6-8) of a 4-week programme. Squat jump (SJ) peak power (PP) and mean power (MP), and box squat (BS) one repetition maximum (1RM) strength were assessed every workout. Saliva was collected across each workout and assayed for testosterone (Sal-T) and cortisol (Sal-C). The T(SPRINT) and T(CONTROL) groups both showed significant improvements in SJ PP (8.2 +/- 2.9 vs. 11.9 +/- 3.6%), SJ MP (11.8 +/- 2.6 vs. 18.6 +/- 4.8%) and BS 1RM (20.5 +/- 2.6 vs. 23.2 +/- 1.3%), respectively. However, there were no group differences in training adaptation, workout performance or the workout hormonal responses. As a combined group (all players), significant relationships were demonstrated between resting Sal-T and/or Sal-C concentrations and absolute SJ power (r = 0.20-0.30) and BS strength (r = 0.36-0.44) across all workouts. For individual players, the respective relationships with SJ power (r = 0.22-0.42) and BS strength (r = 0.41-0.49) were, on average, found to be stronger. In conclusion, leg workouts performed with or without prior cycle sprints can produce similar power and strength improvements in semi-elite rugby players. Resting salivary hormone concentrations appear important for workout performance, especially for individuals, thereby potentially moderating training adaptation.
Bernstein, Eric F; Bloom, Jason D; Basilavecchio, Lisa D; Plugis, Jessica M
2014-01-01
Background and Objectives A sharply contoured cryolipolysis vacuum applicator was developed to improve fit and tissue draw in the abdomen and flanks to better accommodate a range of body types and a variety of treatment sites. This study was carried out to evaluate the safety and efficacy of the new applicator for treatment of flank fat (“love handles”). Study Design/Materials and Methods A cryolipolysis vacuum applicator with a sharply contoured cup and curved cooling plates was used to treat 20 flanks. Two treatment cycles were delivered sequentially to each flank (60-minute cycle at a Cooling Intensity Factor of 41.6). Efficacy was evaluated 12 weeks post-treatment by physicians performing blinded, independent review of clinical photographs. Safety was assessed by the treating physician monitoring subjects for side effects and adverse events. Results Four blinded, independent physician reviewers properly identified the pre- and post-treatment photographs 94.4% of the time. Improvement was scored from 0 (none) to 10 (complete) and showed an average 4.3 point (43%) improvement. Side-effects were limited to erythema, edema, bruising, and numbness or tingling at the treatment site, and resolved without treatment. Conclusions Multiple treatment cycles from a new improved-fit cryolipolysis applicator are safe and effective for reduction of flank fat bulges. A high degree of improvement was reported by blinded, physician evaluation of standardized photographs. Laser Surg. Med. 46:731–735, 2014. © 2014 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc. PMID:25395266
A comprehensive approach for diagnosing opportunities for improving the performance of a WWTP.
Silva, C; Matos, J Saldanha; Rosa, M J
2016-12-01
High quality services of wastewater treatment require a continuous assessment and improvement of the technical, environmental and economic performance. This paper demonstrates a comprehensive approach for benchmarking wastewater treatment plants (WWTPs), using performance indicators (PIs) and indices (PXs), in a 'plan-do-check-act' cycle routine driven by objectives. The performance objectives herein illustrated were to diagnose the effectiveness and energy performance of an oxidation ditch WWTP. The PI and PX results demonstrated an effective and reliable oxidation ditch (good-excellent performance), and a non-reliable UV disinfection (unsatisfactory-excellent performance) related with influent transmittance and total suspended solids. The energy performance increased with the treated wastewater volume and was unsatisfactory below 50% of plant capacity utilization. The oxidation ditch aeration performed unsatisfactorily and represented 38% of the plant energy consumption. The results allowed diagnosing opportunities for improving the energy and economic performance considering the influent flows, temperature and concentrations, and for levering the WWTP performance to acceptable-good effectiveness, reliability and energy efficiency. Regarding the plant reliability for fecal coliforms, improvement of UV lamp maintenance and optimization of the UV dose applied and microscreen recommissioning were suggested.
Analysis of different image-based biofeedback models for improving cycling performances
NASA Astrophysics Data System (ADS)
Bibbo, D.; Conforto, S.; Bernabucci, I.; Carli, M.; Schmid, M.; D'Alessio, T.
2012-03-01
Sport practice can take advantage from the quantitative assessment of task execution, which is strictly connected to the implementation of optimized training procedures. To this aim, it is interesting to explore the effectiveness of biofeedback training techniques. This implies a complete chain for information extraction containing instrumented devices, processing algorithms and graphical user interfaces (GUIs) to extract valuable information (i.e. kinematics, dynamics, and electrophysiology) to be presented in real-time to the athlete. In cycling, performance indexes displayed in a simple and perceivable way can help the cyclist optimize the pedaling. To this purpose, in this study four different GUIs have been designed and used in order to understand if and how a graphical biofeedback can influence the cycling performance. In particular, information related to the mechanical efficiency of pedaling is represented in each of the designed interfaces and then displayed to the user. This index is real-time calculated on the basis of the force signals exerted on the pedals during cycling. Instrumented pedals for bikes, already designed and implemented in our laboratory, have been used to measure those force components. A group of subjects underwent an experimental protocol and pedaled with (the interfaces have been used in a randomized order) and without graphical biofeedback. Preliminary results show how the effective perception of the biofeedback influences the motor performance.
Kumyaito, Nattapon; Yupapin, Preecha; Tamee, Kreangsak
2018-01-08
An effective training plan is an important factor in sports training to enhance athletic performance. A poorly considered training plan may result in injury to the athlete, and overtraining. Good training plans normally require expert input, which may have a cost too great for many athletes, particularly amateur athletes. The objectives of this research were to create a practical cycling training plan that substantially improves athletic performance while satisfying essential physiological constraints. Adaptive Particle Swarm Optimization using ɛ-constraint methods were used to formulate such a plan and simulate the likely performance outcomes. The physiological constraints considered in this study were monotony, chronic training load ramp rate and daily training impulse. A comparison of results from our simulations against a training plan from British Cycling, which we used as our standard, showed that our training plan outperformed the benchmark in terms of both athletic performance and satisfying all physiological constraints.
Liu, Xianghong; Si, Wenping; Zhang, Jun; Sun, Xiaolei; Deng, Junwen; Baunack, Stefan; Oswald, Steffen; Liu, Lifeng; Yan, Chenglin; Schmidt, Oliver G
2014-12-12
With Fe2O3 as a proof-of-concept, free-standing nanomembrane structure is demonstrated to be highly advantageous to improve the performance of Li-ion batteries. The Fe2O3 nanomembrane electrodes exhibit ultra-long cycling life at high current rates with satisfactory capacity (808 mAh g(-1) after 1000 cycles at 2 C and 530 mAh g(-1) after 3000 cycles at 6 C) as well as repeatable high rate capability up to 50 C. The excellent performance benefits particularly from the unique structural advantages of the nanomembranes. The mechanical feature can buffer the strain of lithiation/delithiation to postpone the pulverization. The two-dimensional transport pathways in between the nanomembranes can promote the pseudo-capacitive type storage. The parallel-laid nanomembranes, which are coated by polymeric gel-like film and SEI layer with the electrolyte in between layers, electrochemically behave like numerous "mini-capacitors" to provide the pseudo-capacitance thus maintain the capacity at high rate.
Luo, Shaojuan; Zhao, Jinlai; Zou, Jifei; He, Zhiliang; Xu, Changwen; Liu, Fuwei; Huang, Yang; Dong, Lei; Wang, Lei; Zhang, Han
2018-01-31
With the rapid development of portable electronics, solid-state flexible supercapacitors (SCs) are considered as one of the promising energy devices in powering electronics because of their intrinsic advantages. Polypyrrole (PPy) is an ideal electrode material in constructing flexible SCs owing to its high electrochemical activity and inherent flexibility, although its relatively low capacitance and poor cycling stability are still worthy of improvement. Herein, through the innovative introduction of black phosphorus (BP) nanosheets, we developed a laminated PPy/BP self-standing film with enhanced capacitance and cycling stability via a facile one-step electrochemical deposition method. The film exhibits a high capacitance of 497.5 F g -1 (551.7 F cm -3 ) and outstanding cycling stability of 10 000 charging/discharging cycles, thanks to BP nanosheets inducing laminated assembly which hinder dense and disordered stacking of PPy during electrodeposition, consequently providing a precise pathway for ion diffusion and electron transport together with alleviation of the structural deterioration during charge/discharge. The flexible SC fabricated by laminated films delivers a high capacitance of 452.8 F g -1 (7.7 F cm -3 ) besides its remarkable mechanical flexibility and cycling stability. Our facile strategy paves the way to improve the electrochemical performance of PPy-based SC that could serve as promising flexible energy device for portable electronics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Fricke, Brian A; Vineyard, Edward Allan
Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; systemmore » performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Qingmei, E-mail: suqingmei@zjnu.cn; Yuan, Weiwei; Yao, Libing
2015-12-15
Highlights: • Co{sub 3}O{sub 4}–graphene nanocomposites are prepared by microwave irradiation method. • Co{sub 3}O{sub 4} nanosheets exhibit porous structure with the pore sizes of 3–6 nm. • The porous Co{sub 3}O{sub 4}–graphene nanocomposites show excellent electrochemical performance. • Synergistic effects of Co{sub 3}O{sub 4} and graphene improve the electrochemical performance. - Abstract: Porous Co{sub 3}O{sub 4} nanosheets anchored on graphene nanosheets were synthesized by microwave irradiation method. The obtained Co{sub 3}O{sub 4}–graphene sheet-on-sheet nanocomposite as an anode material for LIBs demonstrates a high initial discharge capacity of 1359.6 mAh g{sup −1} with a Columbic efficiency of 72.7% at amore » rate of 100 mA g{sup −1}. Moreover, a significantly enhanced reversible capacity of ∼1036.9 mAh g{sup −1} is retained after 50 cycles, and the capacity can reincrease to 1068 mAh g{sup −1} when the current density returns back to 100 mA g{sup −1} after cycled at various rates for 50 cycles. The improved electrochemical performance is attributed to the unique architectures of the porous Co{sub 3}O{sub 4} nanosheets and the incorporation of graphene nanosheets. Therefore, this nanocomposite is widely considered to be an attractive candidate as an anode material for next-generation LIBs.« less
NASA Astrophysics Data System (ADS)
Wieder, William R.; Cleveland, Cory C.; Lawrence, David M.; Bonan, Gordon B.
2015-04-01
Uncertainties in terrestrial carbon (C) cycle projections increase uncertainty of potential climate feedbacks. Efforts to improve model performance often include increased representation of biogeochemical processes, such as coupled carbon-nitrogen (N) cycles. In doing so, models are becoming more complex, generating structural uncertainties in model form that reflect incomplete knowledge of how to represent underlying processes. Here, we explore structural uncertainties associated with biological nitrogen fixation (BNF) and quantify their effects on C cycle projections. We find that alternative plausible structures to represent BNF result in nearly equivalent terrestrial C fluxes and pools through the twentieth century, but the strength of the terrestrial C sink varies by nearly a third (50 Pg C) by the end of the twenty-first century under a business-as-usual climate change scenario representative concentration pathway 8.5. These results indicate that actual uncertainty in future C cycle projections may be larger than previously estimated, and this uncertainty will limit C cycle projections until model structures can be evaluated and refined.
NASA Astrophysics Data System (ADS)
Ambarita, H.; Sihombing, H. V.
2018-03-01
Vapor compression cycle is mainly employed as a refrigeration cycle in the Air-Conditioning (AC) unit. In order to save energy, the Coefficient of Performance (COP) of the need to be improved. One of the potential solutions is to modify the system into multi-stages vapor compression cycle. The suitable intermediate pressure between the high and low pressures is one of the design issues. The present work deals with the investigation of an optimum intermediate pressure of two-stages vapor compression refrigeration cycle. Typical vapor compression cycle that is used in AC unit is taken into consideration. The used refrigerants are R134a. The governing equations have been developed for the systems. An inhouse program has been developed to solve the problem. COP, mass flow rate of the refrigerant and compressor power as a function of intermediate pressure are plotted. It was shown that there exists an optimum intermediate pressure for maximum COP. For refrigerant R134a, the proposed correlations need to be revised.
Genetic progress estimation strategy for upright common bean plants using recurrent selection.
Pereira, L A; Abreu, A F B; Júnior, I C Vieira; Pires, L P M; Ramalho, M A P
2017-03-22
Common bean producers in Brazil tend to grow plants as upright as possible. Because the control of this trait involves a large number of genes, recurrent selection (RS) is the best approach for successful plant improvement. Because plant architecture (PA) is evaluated using scores and usually has high heritability, RS for PA is performed through visual selection in generation S 0 . The aim of the present study was to evaluate selection progress and investigate whether this progress varies with the number of selected progenies or the generation evaluated. In addition, the effect of RS for the upright (PA) trait on progeny grain yield (GY) was investigated. Data of progenies S 0:3 and S 0:4 of the fifth, eighth, and twelfth cycles were used. A combined analysis of variance was performed using the adjusted means of the 47 best progenies from each generation and cycle, using two control cultivars as reference. A joint analysis of the two generations used during the evaluation of progenies for the different cycles was also performed. The genetic progress (GP) was estimated by fitting a linear regression equation to the relationship between the adjusted mean of each cycle and the number of cycles. We found that RS was efficient and the estimated GP of the evaluated progenies was 4.5%. Based on the GY heritability estimates, in more advanced generation selection for GY can be successfully performed on progenies. Thus, the selection already done for PA in F 2 could be associated to the most productive progenies.
Assisted reproductive technology with donor sperm: national trends and perinatal outcomes.
Gerkowicz, Sabrina A; Crawford, Sara B; Hipp, Heather S; Boulet, Sheree L; Kissin, Dmitry M; Kawwass, Jennifer F
2018-04-01
Information regarding the use of donor sperm in assisted reproductive technology, as well as subsequent treatment and perinatal outcomes, remains limited. Outcome data would aid patient counseling and clinical decision making. The objectives of the study were to report national trends in donor sperm utilization and live birth rates of donor sperm-assisted reproductive technology cycles in the United States and to compare assisted reproductive technology treatment and perinatal outcomes between cycles using donor and nondonor sperm. We hypothesize these outcomes to be comparable between donor and nondonor sperm cycles. This was a retrospective cohort study using data from all US fertility centers reporting to the Centers for Disease Control and Prevention's National Assisted Reproductive Technology Surveillance System, accounting for ∼98% of assisted reproductive technology cycles (definition excludes intrauterine insemination). The number and percentage of assisted reproductive technology cycles using donor sperm and rates of pregnancy, live birth, preterm birth (<37 weeks), and low birthweight (<2500 g) were the primary outcomes measured. Treatments assessed include use of donor vs nondonor sperm. The trends analysis included all banking and fresh assisted reproductive technology cycles using donor and autologous oocytes performed between 1996 and 2014 (n = 1,710,034). The outcomes analysis was restricted to include only fresh autologous cycles performed between 2010 and 2014 (n = 437,569) to focus on cycles with a potential outcome and cycles reflective of current practice, thereby improving the clinical relevance. Cycles canceled prior to retrieval were excluded. Statistical analysis included linear regression to explore polynomial trends and log-binomial regression to estimate relative risk for outcomes among cycles using donor and nondonor sperm. Of all banking and fresh donor and autologous oocyte assisted reproductive technology cycles performed between 1996 and 2014, 74,892 (4.4%) used donor sperm. In 2014, 7351 assisted reproductive technology cycles using donor sperm were performed, as compared with 1763 in 1996 (6.2% vs 3.8% of all cycles). Among all autologous oocyte cycles performed between 2010 and 2014, the live birth rate was lower for donor sperm (27.9%) than nondonor sperm cycles (32.5%); however, after adjustment for maternal age, donor sperm use was associated with an increased likelihood of live birth (adjusted relative risk, 1.06, 95% confidence interval, 1.01-1.10). Per transfer, there was no significant difference in live birth rates for donor vs nondonor sperm (31.9% vs 36.8%; adjusted relative risk, 1.04, 95% confidence interval, 0.998-1.09). Per singleton live birth, there was no significant difference in preterm birth (11.5% vs 11.8%; adjusted relative risk, 0.98, 95% confidence interval, 0.90-1.06); however, low birthweight delivery was slightly lower in donor sperm cycles (8.8% vs 9.4%; adjusted relative risk, 0.91, 95% confidence interval, 0.83-0.99). Donor sperm use in assisted reproductive technology has increased in the United States, accounting for approximately 6% of all assisted reproductive technology cycles in 2014. Assisted reproductive technology treatment and perinatal outcomes were clinically similar in donor and nondonor sperm cycles. Copyright © 2018 Elsevier Inc. All rights reserved.
Improving performances of the knee replacement surgery process by applying DMAIC principles.
Improta, Giovanni; Balato, Giovanni; Romano, Maria; Ponsiglione, Alfonso Maria; Raiola, Eliana; Russo, Mario Alessandro; Cuccaro, Patrizia; Santillo, Liberatina Carmela; Cesarelli, Mario
2017-12-01
The work is a part of a project about the application of the Lean Six Sigma to improve health care processes. A previously published work regarding the hip replacement surgery has shown promising results. Here, we propose an application of the DMAIC (Define, Measure, Analyse, Improve, and Control) cycle to improve quality and reduce costs related to the prosthetic knee replacement surgery by decreasing patients' length of hospital stay (LOS) METHODS: The DMAIC cycle has been adopted to decrease the patients' LOS. The University Hospital "Federico II" of Naples, one of the most important university hospitals in Southern Italy, participated in this study. Data on 148 patients who underwent prosthetic knee replacement between 2010 and 2013 were used. Process mapping, statistical measures, brainstorming activities, and comparative analysis were performed to identify factors influencing LOS and improvement strategies. The study allowed the identification of variables influencing the prolongation of the LOS and the implementation of corrective actions to improve the process of care. The adopted actions reduced the LOS by 42%, from a mean value of 14.2 to 8.3 days (standard deviation also decreased from 5.2 to 2.3 days). The DMAIC approach has proven to be a helpful strategy ensuring a significant decreasing of the LOS. Furthermore, through its implementation, a significant reduction of the average costs of hospital stay can be achieved. Such a versatile approach could be applied to improve a wide range of health care processes. © 2017 John Wiley & Sons, Ltd.
Advances in rechargeable lithium molybdenum disulfide batteries
NASA Technical Reports Server (NTRS)
Brandt, K.; Stiles, J. A. R.
1985-01-01
The lithium molybdenum disulfide system as demonstrated in a C size cell, offers performance characteristics for applications where light weight and low volume are important. A gravimetric energy density of 90 watt hours per kilogram can be achieved in a C size cell package. The combination of charge retention capabilities, high energy density and a state of charge indicator in a rechargeable cell provides power package for a wide range of devices. The system overcomes the memory effect in Nicads where the full capacity of the battery cannot be utilized unless it was utilized on previous cycles. The development of cells with an advanced electrolyte formulation led to an improved rate capability especially at low temperatures and to a significantly improved life cycle.
Overview of the Turbine Based Combined Cycle Discipline
NASA Technical Reports Server (NTRS)
Thomas, Scott R.; Walker, James F.; Pittman, James L.
2009-01-01
The NASA Fundamental Aeronautics Hypersonics project is focused on technologies for combined cycle, airbreathing propulsions systems to enable reusable launch systems for access to space. Turbine Based Combined Cycle (TBCC) propulsion systems offer specific impulse (Isp) improvements over rocket-based propulsion systems in the subsonic takeoff and return mission segments and offer improved safety. The potential to realize more aircraft-like operations with expanded launch site capability and reduced system maintenance are additional benefits. The most critical TBCC enabling technologies as identified in the National Aeronautics Institute (NAI) study were: 1) mode transition from the low speed propulsion system to the high speed propulsion system, 2) high Mach turbine engine development, 3) transonic aero-propulsion performance, 4) low-Mach-number dual-mode scramjet operation, 5) innovative 3-D flowpath concepts and 6) innovative turbine based combined cycle integration. To address several of these key TBCC challenges, NASA s Hypersonics project (TBCC Discipline) initiated an experimental mode transition task that includes an analytic research endeavor to assess the state-of-the-art of propulsion system performance and design codes. This initiative includes inlet fluid and turbine performance codes and engineering-level algorithms. This effort has been focused on the Combined Cycle Engine Large-Scale Inlet Mode Transition Experiment (CCE LIMX) which is a fully integrated TBCC propulsion system with flow path sizing consistent with previous NASA and DoD proposed Hypersonic experimental flight test plans. This experiment is being tested in the NASA-GRC 10 x 10 Supersonic Wind Tunnel (SWT) Facility. The goal of this activity is to address key hypersonic combined-cycle-engine issues: (1) dual integrated inlet operability and performance issues unstart constraints, distortion constraints, bleed requirements, controls, and operability margins, (2) mode-transition constraints imposed by the turbine and the ramjet/scramjet flow paths (imposed variable geometry requirements), (3) turbine engine transients (and associated time scales) during transition, (4) high-altitude turbine engine re-light, and (5) the operating constraints of a Mach 3-7 combustor (specific to the TBCC). The model will be tested in several test phases to develop a unique TBCC database to assess and validate design and analysis tools and address operability, integration, and interaction issues for this class of advanced propulsion systems. The test article and all support equipment is complete and available at the facility. The test article installation and facility build-up in preparation for the inlet performance and operability characterization is near completion and testing is planned to commence in FY11.
Disaster easily averted? Data confidentiality and the hospital desktop computer.
Sethi, Neeraj; Lane, Gethin; Newton, Sophie; Egan, Philip; Ghosh, Samit
2014-05-01
We specifically identified the hospital desktop computer as a potential source of breaches in confidentiality. We aimed to evaluate if there was accessible, unprotected, confidential information stored on the desktop screen on computers in a district general hospital and if so, how a teaching intervention could improve this situation. An unannounced spot check of 59 ward computers was performed. Data were collected regarding how many had confidential information stored on the desktop screen without any password protection. An online learning module was mandated for healthcare staff and a second cycle of inspection performed. A district general hospital. Two doctors conducted the audit. Computers in clinical areas were assessed. All clinical staff with computer access underwent the online learning module. An online learning module regarding data protection and confidentiality. In the first cycle, 55% of ward computers had easily accessible patient or staff confidential information stored on their desktop screen. This included handovers, referral letters, staff sick leave lists, audits and nursing reports. The majority (85%) of computers accessed were logged in under a generic username and password. The intervention produced an improvement in the second cycle findings with only 26% of computers being found to have unprotected confidential information stored on them. The failure to comply with appropriate confidential data protection regulations is a persistent problem. Education produces some improvement but we also propose a systemic approach to solving this problem. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Fan, Yu-Jen; Maruyama, Ken; Ayothi, Ramakrishnan; Naruoka, Takehiko; Chakraborty, Tonmoy; Ashworth, Dominic; Chun, Jun Sung; Montgomery, Cecilia; Jen, Shih-Hui; Neisser, Mark; Cummings, Kevin
2015-03-01
In this paper, we present the first results of witness sample based outgas resist family test to improve the efficiency of outgas testing using EUV resists that have shown proven imaging performance. The concept of resist family testing is to characterize the boundary conditions of outgassing scale from three major components for each resist family. This achievement can significantly reduce the cost and improve the resist outgas learning cycle. We also report the imaging performance and outgas test results of state of the art resists and discuss the consequence of the resist development with recent change of resist outgassing specifications. Three chemically amplified resists selected from higher outgassing materials are investigated, but no significant improvement in resist performance is observed.
DOT National Transportation Integrated Search
2001-10-01
Public agencies across the country are pursuing innovative project delivery methods such as design-build (D-B) and construction manager-at-risk (CM-at-risk) to improve cycle-time performance on projects, and numerous transportation departments are cu...
DOT National Transportation Integrated Search
1976-07-01
The Federal Railroad Administration (FRA) is sponsoring research, development, and demonstration programs to provide improved safety, performance, speed, reliability, and maintainability of rail transportation systems at reduced life-cycle costs. A m...
Sun, Shuwei; Yin, Yanfeng; Wan, Ning; ...
2015-06-24
For Li-rich layered cathode materials considerable attention has been paid owing to their high capacity performance for Li-ion batteries (LIBs). In our work, layered Li-rich Li[Li 0.2Ni 0.17Co 0.07Mn 0.56]O 2 nanoparticles are surface-modified with AlF 3 through a facile chemical deposition method. The AlF 3 surface layers have little impact on the structure of the material and act as buffers to prevent the direct contact of the electrode with the electrolyte; thus, they enhance the electrochemical performance significantly. The 3 wt% AlF 3-coated Li-rich electrode exhibits the best cycling capability and has a considerably enhanced capacity retention of 83.1%more » after 50 cycles. Moreover, the rate performance and thermal stability of the 3 wt% AlF3-coated electrode are also clearly improved. Finally, surface analysis indicates that the AlF 3 coating layer can largely suppress the undesirable growth of solid electrolyte interphase (SEI) film and, therefore, stabilizes the structure upon cycling.« less
Ma, Guofu; Hua, Fengting; Sun, Kanjun; Fenga, Enke; Peng, Hui; Zhang, Zhiguo; Lei, Ziqiang
2018-01-01
The electrochemical performance of an energy conversion and storage device like the supercapacitor mainly depends on the microstructure and morphology of the electrodes. In this paper, to improve the capacitance performance of the supercapacitor, the all-pseudocapacitive electrodes of lamella-like Bi 18 SeO 29 /BiSe as the negative electrode and flower-like Co 0.85 Se nanosheets as the positive electrode are synthesized by using a facile low-temperature one-step hydrothermal method. The microstructures and morphology of the electrode materials are carefully characterized, and the capacitance performances are also tested. The Bi 18 SeO 29 /BiSe and Co 0.85 Se have high specific capacitance (471.3 F g -1 and 255 F g -1 at 0.5 A g -1 ), high conductivity, outstanding cycling stability, as well as good rate capability. The assembled asymmetric supercapacitor completely based on the pseudocapacitive electrodes exhibits outstanding cycling stability (about 93% capacitance retention after 5000 cycles). Moreover, the devices exhibit high energy density of 24.2 Wh kg -1 at a power density of 871.2 W kg -1 in the voltage window of 0-1.6 V with 2 M KOH solution.
Design and Comparative Study of O3/P2 Hybrid Structures for Room Temperature Sodium-Ion Batteries.
Qi, Xingguo; Liu, Lilu; Song, Ningning; Gao, Fei; Yang, Kai; Lu, Yaxiang; Yang, Haitao; Hu, Yong-Sheng; Cheng, Zhao-Hua; Chen, Liquan
2017-11-22
Rechargeable sodium-ion batteries have drawn increasing attention as candidates for the post lithium-ion batteries in large-scale energy storage systems. Layered oxides are the most promising cathode materials and their pure phases (e.g., P2, O3) have been widely investigated. Here we report a series of cathode materials with O3/P2 hybrid phase for sodium-ion batteries, which possesses advantages of both P2 and O3 structures. The designed material, Na 0.78 Ni 0.2 Fe 0.38 Mn 0.42 O 2 , can deliver a capacity of 86 mAh g -1 with great rate capability and cycling performance. 66% capacity is still maintained when the current rate reaches as high as 10C, and the capacity retention is 90% after 1500 cycles. Moreover, in situ XRD was performed to examine the structure change during electrochemical testing in different voltage ranges, and the results demonstrate 4 V as the optimized upper voltage limit, with which smaller polarization, better structural stability, and better cycling performance are achieved. The results obtained here provide new insights in designing cathode materials with optimal structure and improved performance for sodium-ion batteries.
Solar dynamic power system definition study
NASA Technical Reports Server (NTRS)
Wallin, Wayne E.; Friefeld, Jerry M.
1988-01-01
The solar dynamic power system design and analysis study compared Brayton, alkali-metal Rankine, and free-piston Stirling cycles with silicon planar and GaAs concentrator photovoltaic power systems for application to missions beyond the Phase 2 Space Station level of technology for all power systems. Conceptual designs for Brayton and Stirling power systems were developed for 35 kWe and 7 kWe power levels. All power systems were designed for 7-year end-of-life conditions in low Earth orbit. LiF was selected for thermal energy storage for the solar dynamic systems. Results indicate that the Stirling cycle systems have the highest performance (lowest weight and area) followed by the Brayton cycle, with photovoltaic systems considerably lower in performance. For example, based on the performance assumptions used, the planar silicon power system weight was 55 to 75 percent higher than for the Stirling system. A technology program was developed to address areas wherein significant performance improvements could be realized relative to the current state-of-the-art as represented by Space Station. In addition, a preliminary evaluation of hardenability potential found that solar dynamic systems can be hardened beyond the hardness inherent in the conceptual designs of this study.
Dong, Yingnan; Demeaux, Julien; Zhang, Yuzi; ...
2016-12-13
Performance of LiNi 0.5Mn 1.5O 4/graphite cells cycled to 4.8 V at 55°C with the 1.2 M LiPF 6 in EC/EMC (3/7, STD electrolyte) with and without added lithium catechol dimethyl borate (LiCDMB) has been investigated. The incorporation of 0.5 wt% LiCDMB to the STD electrolyte results in an improved capacity retention and coulombic efficiency upon cycling at 55°C. Ex-situ analysis of the electrode surfaces via a combination of SEM, TEM, and XPS reveals that oxidation of LiCDMB at high potential results in the deposition of a passivation layer on the electrode surface, preventing transition metal ion dissolution from themore » cathode and subsequent deposition on the anode. NMR investigations of the bulk electrolyte stored at 85°C reveals that added LiCDMB prevents the thermal decomposition of LiPF 6.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Yingnan; Demeaux, Julien; Zhang, Yuzi
Performance of LiNi 0.5Mn 1.5O 4/graphite cells cycled to 4.8 V at 55°C with the 1.2 M LiPF 6 in EC/EMC (3/7, STD electrolyte) with and without added lithium catechol dimethyl borate (LiCDMB) has been investigated. The incorporation of 0.5 wt% LiCDMB to the STD electrolyte results in an improved capacity retention and coulombic efficiency upon cycling at 55°C. Ex-situ analysis of the electrode surfaces via a combination of SEM, TEM, and XPS reveals that oxidation of LiCDMB at high potential results in the deposition of a passivation layer on the electrode surface, preventing transition metal ion dissolution from themore » cathode and subsequent deposition on the anode. NMR investigations of the bulk electrolyte stored at 85°C reveals that added LiCDMB prevents the thermal decomposition of LiPF 6.« less
Monodisperse Porous Silicon Spheres as Anode Materials for Lithium Ion Batteries
NASA Astrophysics Data System (ADS)
Wang, Wei; Favors, Zachary; Ionescu, Robert; Ye, Rachel; Bay, Hamed Hosseini; Ozkan, Mihrimah; Ozkan, Cengiz S.
2015-03-01
Highly monodisperse porous silicon nanospheres (MPSSs) are synthesized via a simple and scalable hydrolysis process with subsequent surface-protected magnesiothermic reduction. The spherical nature of the MPSSs allows for a homogenous stress-strain distribution within the structure during lithiation and delithiation, which dramatically improves the electrochemical stability. To fully extract the real performance of the MPSSs, carbon nanotubes (CNTs) were added to enhance the electronic conductivity within the composite electrode structure, which has been verified to be an effective way to improve the rate and cycling performance of anodes based on nano-Si. The Li-ion battery (LIB) anodes based on MPSSs demonstrate a high reversible capacity of 3105 mAh g-1. In particular, reversible Li storage capacities above 1500 mAh g-1 were maintained after 500 cycles at a high rate of C/2. We believe this innovative approach for synthesizing porous Si-based LIB anode materials by using surface-protected magnesiothermic reduction can be readily applied to other types of SiOx nano/microstructures.
Monodisperse porous silicon spheres as anode materials for lithium ion batteries.
Wang, Wei; Favors, Zachary; Ionescu, Robert; Ye, Rachel; Bay, Hamed Hosseini; Ozkan, Mihrimah; Ozkan, Cengiz S
2015-03-05
Highly monodisperse porous silicon nanospheres (MPSSs) are synthesized via a simple and scalable hydrolysis process with subsequent surface-protected magnesiothermic reduction. The spherical nature of the MPSSs allows for a homogenous stress-strain distribution within the structure during lithiation and delithiation, which dramatically improves the electrochemical stability. To fully extract the real performance of the MPSSs, carbon nanotubes (CNTs) were added to enhance the electronic conductivity within the composite electrode structure, which has been verified to be an effective way to improve the rate and cycling performance of anodes based on nano-Si. The Li-ion battery (LIB) anodes based on MPSSs demonstrate a high reversible capacity of 3105 mAh g(-1). In particular, reversible Li storage capacities above 1500 mAh g(-1) were maintained after 500 cycles at a high rate of C/2. We believe this innovative approach for synthesizing porous Si-based LIB anode materials by using surface-protected magnesiothermic reduction can be readily applied to other types of SiOx nano/microstructures.
Measurement, Standards, and Peer Benchmarking: One Hospital's Journey.
Martin, Brian S; Arbore, Mark
2016-04-01
Peer-to-peer benchmarking is an important component of rapid-cycle performance improvement in patient safety and quality-improvement efforts. Institutions should carefully examine critical success factors before engagement in peer-to-peer benchmarking in order to maximize growth and change opportunities. Solutions for Patient Safety has proven to be a high-yield engagement for Children's Hospital of Pittsburgh of University of Pittsburgh Medical Center, with measureable improvement in both organizational process and culture. Copyright © 2016 Elsevier Inc. All rights reserved.
Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald
2012-04-30
Ultra-endurance performance is of increasing popularity. We investigated the associations between anthropometry, training and support during racing, with race performance in 67 male recreational ultra-endurance cyclists participating in the 'Swiss Cycling Marathon' over 600 kilometres, an official qualifier for the cycling ultra-marathon 'Paris-Brest-Paris'. The 54 finishers showed no differences in anthropometry and did not train differently compared to the 13 non-finishers. During the race, the finishers were significantly more frequently racing alone than being followed by a support crew. After bivariate analysis, percent body fat (r = 0.43), the cycling distance per training unit (r = -0.36), the duration per training unit (r = -0.31) and the sleep time during the race (r = 0.50) were related to overall race time. The 23 non-sleepers in the finisher group completed the race within (mean and IQR) 1,567 (1,453-1,606) min, highly significantly faster than the 31 sleepers with 1,934 (1,615-2,033) min (P = 0.0003). No variable of support during the race was associated with race time. After multivariate analysis, percent body fat (P = 0.026) and duration per training unit (P = 0.005) remained predictor variables for race time. To summarize, for a successful finish in a cycling ultra-marathon over 600 kilometres such as the 'Swiss Cycling Marathon', percent body fat and duration per training unit were related to race time whereas equipment and support during the race showed no association. Athletes with naps were highly significantly slower than athletes without naps.
Zhang, Cheng; Wei, Jun; Chen, Leiyi; Tang, Shaolong; Deng, Mingsen; Du, Youwei
2017-10-19
An asymmetric supercapacitor offers opportunities to effectively utilize the full potential of the different potential windows of the two electrodes for a higher operating voltage, resulting in an enhanced specific capacitance and significantly improved energy without sacrificing the power delivery and cycle life. To achieve high energy and power densities, we have synthesized an all-solid-state asymmetric supercapacitor with a wider voltage range using Fe-doped Co 3 O 4 and three-dimensional reduced graphene oxide (3DrGO) as the positive and negative electrodes, respectively. In contrast to undoped Co 3 O 4 , the increased density of states and modified charge spatial separation endow the Fe-doped Co 3 O 4 electrode with greatly improved electrochemical capacitive performance, including high specific capacitance (1997 F g -1 and 1757 F g -1 at current densities of 1 and 20 A g -1 , respectively), excellent rate capability, and superior cycling stability. Remarkably, the optimized all-solid-state asymmetric supercapacitor can be cycled reversibly in a wide range of 0-1.8 V, thus delivering a high energy density (270.3 W h kg -1 ), high power density (9.0 kW kg -1 at 224.2 W h kg -1 ), and excellent cycling stability (91.8% capacitance retention after 10 000 charge-discharge cycles at a constant current density of 10 A g -1 ). The superior capacitive performance suggests that such an all-solid-state asymmetric supercapacitor shows great potential for developing energy storage systems with high levels of energy and power delivery.
Development and validation of cryogenic foam insulation for LH2 subsonic transports
NASA Technical Reports Server (NTRS)
Anthony, F. M.; Colt, J. Z.; Helenbrook, R. G.
1981-01-01
Fourteen foam insulation specimens were tested. Some were plain foam while others contained flame retardants, chopped fiberglass reinforcement and/or vapor barriers. The thermal performance of the insulation was determined by measuring the rate at which LH2 boiled from an aluminum tank insulated with the test material. The test specimens were approximately 50 mm (2 in.) thick. They were structurally scaled so that the test cycle would duplicate the maximum thermal stresses predicted for the thicker insulation of an aircraft liquid hydrogen fuel tank during a typical subsonic flight. The simulated flight cycle of approximately 10 minutes duration heated the other insulation surface to 316 K (110 F) and cooled it to 226 K (20 F) while the inner insulation surface remained at liquid hydrogen temperature of 20 K (-423 F). Two urethane foam insulations exceeded the initial life goal of 2400 simulated flight cycles and sustained 4400 cycles with only minor damage. The addition of fiberglass reinforcement of flame retardant materials to an insulation degraded thermal performance and/or the life of the foam material. Installation of vapor barriers enhanced the structural integrity of the material but did not improve thermal performance. All of the foams tested were available materials; none were developed specifically for LH2 service.
Mir Cooperative Solar Array Project Accelerated Life Thermal Cycling Test
NASA Technical Reports Server (NTRS)
Hoffman, David J.; Scheiman, David A.
1996-01-01
The Mir Cooperative Solar Array (MCSA) project was a joint U.S./Russian effort to build a photovoltaic (PV) solar array and deliver it to the Russian space station Mir. The MCSA will be used to increase the electrical power on Mir and provide PV array performance data in support of Phase 1 of the International Space Station. The MCSA was brought to Mir by space shuttle Atlantis in November 1995. This report describes an accelerated thermal life cycle test which was performed on two samples of the MCSA. In eight months time, two MCSA solar array 'mini' panel test articles were simultaneously put through 24,000 thermal cycles. There was no significant degradation in the structural integrity of the test articles and no electrical degradation, not including one cell damaged early and removed from consideration. The nature of the performance degradation caused by this one cell is briefly discussed. As a result of this test, changes were made to improve some aspects of the solar cell coupon-to-support frame interface on the flight unit. It was concluded from the results that the integration of the U.S. solar cell modules with the Russian support structure would be able to withstand at least 24,000 thermal cycles (4 years on-orbit). This was considered a successful development test.
Wang, Lei; Wang, Dong; Dong, Zhihui; Zhang, Fengxing; Jin, Jian
2013-04-10
From the whole anode electrode of view, we report in this work a system-level strategy of fabrication of reduced graphene oxide (RGO)/SnO2 composite-based anode for lithium ion battery (LIB) to enhance the capacity and cyclic performance of SnO2-based electrode materials. RGO/SnO2 composite was first coated by a nanothick polydopamine (PD) layer and the PD-coated RGO/SnO2 composite was then cross-linked with poly(acrylic acid) (PAA) that was used as a binder to accomplish a whole anode electrode. The cross-link reaction between PAA and PD produced a robust network in the anode system to stabilize the whole anode during cycling. As a result, the designed anode exhibits an outstanding energy capacity up to 718 mAh/g at current density of 100 mA/g after 200 cycles and a good rate performance of 811, 700, 641, and 512 mAh/g at current density of 100, 250, 500, and 1000 mA/g, respectively. Fourier transform IR spectra confirm the formation of cross-link reaction and the stability of the robust network after long-term cycling. Our results indicate the importance of designing interfaces in anode system on achieving improved performance of electrode of LIBs.
Enhanced kinetics of polysulfide redox reactions on Mo2C/CNT in lithium-sulfur batteries.
Razaq, Rameez; Sun, Dan; Xin, Ying; Li, Qian; Huang, Taizhong; Zheng, Lei; Zhang, Zhaoliang; Huang, Yunhui
2018-07-20
Among different energy storage devices, the lithium-sulfur (Li-S) battery is the subject of recent attention. However, the capacity decay caused by polysulfide shuttle leading to sluggish kinetics of polysulfide redox reactions is the main hindrance for its practical application in Li-S batteries. Herein, molybdenum carbide nanoparticles anchored on carbon nanotubes (Mo 2 C/CNT) are reported to serve as an efficient cathode material to enhance the electrochemical kinetics of polysulfide conversion in Li-S batteries. Mo 2 C/CNT shows strong adsorption and activation of polar polysulfides and therefore accelerates the redox kinetics of polysulfides, reduces the energy barrier, effectively mitigates the polarization and polysulfide shuttle, thus improving the electrochemical performance. The S-Mo 2 C/CNT composite with 70 wt% sulfur loading exhibits high specific discharge capacity (1206 mA h g -1 at 0.5 C), excellent high-rate performance, long cycle life (900 cycles), and outstanding Coulombic efficiency (∼100%) at a high rate (2 C) corresponding to a capacity decay of only 0.05%. Remarkably, the S-Mo 2 C/CNT cathode with high areal sulfur loading of 2.5 mg cm -2 exhibits high-rate capacities and stable cycling performance over 100 cycles, offering the potential for use in high energy Li-S batteries.
Enhanced kinetics of polysulfide redox reactions on Mo2C/CNT in lithium–sulfur batteries
NASA Astrophysics Data System (ADS)
Razaq, Rameez; Sun, Dan; Xin, Ying; Li, Qian; Huang, Taizhong; Zheng, Lei; Zhang, Zhaoliang; Huang, Yunhui
2018-07-01
Among different energy storage devices, the lithium–sulfur (Li–S) battery is the subject of recent attention. However, the capacity decay caused by polysulfide shuttle leading to sluggish kinetics of polysulfide redox reactions is the main hindrance for its practical application in Li–S batteries. Herein, molybdenum carbide nanoparticles anchored on carbon nanotubes (Mo2C/CNT) are reported to serve as an efficient cathode material to enhance the electrochemical kinetics of polysulfide conversion in Li–S batteries. Mo2C/CNT shows strong adsorption and activation of polar polysulfides and therefore accelerates the redox kinetics of polysulfides, reduces the energy barrier, effectively mitigates the polarization and polysulfide shuttle, thus improving the electrochemical performance. The S-Mo2C/CNT composite with 70 wt% sulfur loading exhibits high specific discharge capacity (1206 mA h g‑1 at 0.5 C), excellent high-rate performance, long cycle life (900 cycles), and outstanding Coulombic efficiency (∼100%) at a high rate (2 C) corresponding to a capacity decay of only 0.05%. Remarkably, the S-Mo2C/CNT cathode with high areal sulfur loading of 2.5 mg cm‑2 exhibits high-rate capacities and stable cycling performance over 100 cycles, offering the potential for use in high energy Li–S batteries.